LS4600 INSTRUCTION MANUAL. Thank you for choosing another quality product from Amperes Electronics. Speaker Line Surveillance
|
|
- Marybeth McDaniel
- 5 years ago
- Views:
Transcription
1 INSTRUCTION MANUAL LS4600 Speaker Line Surveillance Thank you for choosing another quality product from Amperes Electronics. LS4600 was produced out of extensive research and development effort in which every aspect of line surveillance requirements are studied. It solves the problem faced by many installers using the conventional line monitoring method, by adopting impedance measurement methodology. This shall eliminate the needs to add coupling capacitors to every speakers, rigid cabling rules as well as inaccuracy in detection. Thereby, LS4600 allows branching in cabling works, direct tapping of line to speakers as well as easier setup, without having to trim impedance against a preset reference. LS4600 is built and run by a micro-controller, thus providing a digital platform in setting up your system. User can set various parameters by following the menu displayed in the LCD screen. Among them shall be the high and low limits, buzzer on / off, display backlight, monitoring setup time, auto or manual mode as well as doing manual testing. It shall not be difficult to understand or to install the unit, but it is recommended that a trained personnel is engaged in order to tap the many features available. Before installation, we suggest a thorough read through of the manual is done to avoid any unnecessary damage to your setup. Please keep this manual handy for any future references. VER 3 / 2015
2 Parts Identifications Front view Rear view LCD DISPLAY 2 x 16 digit LCD display with back light setting is used as programming guide as well as measurement indications. The back light can be set to off if required by accessing menu 6 (see programming chart). The back light is set to ON in default. 2. MENU BUTTON Menu switch is used to access main menus. Once pressed momentarily, it shall revert to Menu Setup. Use Next and Prev keys to scroll through other main menus. Once the relevant menu is found, use Enter key to access its following sub menu. To exit sub menus, press Menu key momentararily. 3. BUTTON Used to enter required main menu or its sub menus, confirm values, data or settings. 4. PREV BUTTON Previous key to scroll back to last menu or sub menu. 5. NEXT BUTTON Next key to scroll forward of menus. 6. GREEN NORMAL LEDs The arrays of green LEDs provides the status of the channel which show the normal condition if lit. If both green and red LEDs do not lit for the particular channel, it means that the channel has been bypassed from monitoring. 7. RED FAULT LEDs Once lit, it indicates that the particular channel is at fault ; either open, short or leakage. Refer to the LCD panel for exact condition of fault. PAGE 2
3 Parts Identifications 8. BUZZER LED If fault is detected, a buzzing sound shall be emitted with the LED lit. Buzzer alert can be turned off via programming and this is indicated by this LED V DC POWER SUPPLY PORT The unit requires 24V DC power supply and recommended PSU shall be Amperes PS9400. Only use regulated power supply if other than PS9400 is installed. 10. ZONE TRIGGER OUTPUT PORT When line monitoring is initiated either manually or auto, it shall start in sequence from ch.1 to 6. With each channel under monitoring, a dry contact shall be available at its correspondence zone. This shall provide 24V overriding voltage to volume controllers or local patch panel with overriding relay, thus allowing direct measurement to the speakers. (Refer to Connecting the unit section of the manual). Overriding is required for accurate sensing in which volume controllers set in various position shall have different impedances and such circumstances shall provide false alarm or alert. Recommended practice is that every zone shall have its own 24V overriding circuit back to the rack. If all the overriding circuits are looped, and if the particular zone with volume controller is set to off, the monitoring activity shall cause a burst of audio signal (such as BGM), which lasted for approximately 18 seconds. This shall happen only when a BGM source is presence. If the particular zone is set to OFF (without BGM), the monitoring activity shall not emit audible sound. 11. AMP / ZONE IN - OUT PORTS It is for connections of incoming 100V line signal and output to speakers. Refer to Connecting the Unit in following section. 12. OUTPUT FAULT CONTACT Whenever a fault condition is detected, this port shall provide a dry contact to link to external alerting devices, such as mimic panel, etc. 13. RS485 OUTPUT (OPTIONAL) Event triggered data shall be transmitted with RS485 protocol. This feature is optional and shall be available in future. PAGE 3
4 PUBLIC ADDRESS POWER AMPLIFIER POWER PROTECT CLIP SIGNAL -10 db SIGNAL -40 db PUBLIC ADDRESS POWER AMPLIFIER OVERRIDE POWER PROTECT CLIP SIGNAL -10 db SIGNAL -40 db amperes SPEAKER ZONE SELECT ALL CALL amperes Configuration / Schematic AUDIO SIGNAL INPUTS NOT SHOWN PA 2480 POWER AMPLIFIERS PA V DC VOLTAGE ZS5121 SPEAKER ZONE SELECTOR RACK MOUNT ZONE VOL.CTRL. LS4600 AUDIO SIGNAL 24V DC OVERRIDING ZONE 6 VOLUME CONTROLLERS / PATCH PANEL Zone 1 Speakers Parallel Zone 2 Direct VC Zone 3 VC Parallel Zone 6 The LS4600 detects circuit faults using impedance measurement method. In general, there is no limitation on how the external cabling to speakers or volume controller are run, ie. branching is allow and does not need end line resistors as well as speaker capacitor couplings. LS4600 have been improve all accuracy. It is recommended that periodical manual checking or setup to be made as connections may deteriorate over time and thus affecting overall impedance value. Only 4 wire system is suitable for measurement. 3 wire system may cause undesirable result each time checking is being made due to the presence of volume controllers. PAGE 4
5 Connecting The Unit 24V DC OVERRIDING CONTROL (EP1200A ETC) Loop the 24V DC overriding trigger to the Zone Trig. O/P port +VE +24V add diode repeat FROM ZONE SELECTOR 100V LINE OUTPUT TO SPEAKERS repeat FROM ZONE SELECTOR 100V LINE OUTPUT TO SPEAKERS RS 485 OUTPUT (OPTIONAL) 24V DC +VE POWER -VE Max rating per zone trigger is 3A. Use external relay if required -VE -VE +24V VOLUME CONTROLLERS WITH OVERRIDING RELAY TO MIMIC PANEL / EXTERNAL FAULT INDICATOR ETC ( A DRY CONTACT OUT) It is recommended that separate zone shall have separate overriding circuit. Otherwise, loop all outputs. Disadvantage of looping all outputs : If a particular zone is active (zone on) but the volume controller at a certain area is shut off (eg. zone 1), activation of monitoring from LS4600 of zone 2 shall override the volume controllers at zone 1, thus a burst of audio shall be heard ( such as BGM being currently played). Programming And Setup The last part of the unit installation shall be programming as well as entering required values. Program the unit by following the menus shown in the LCD display panel. Each of the menu and sub menus shall be explained in the following sections. In general, there are 7 main menus as shown below : MAIN MENU 1.0 SETUP 3.0 MEM. RECALL 5.0 BUZZER 7.0 MEMORY 2.0 MANUAL TEST 4.0 AUTO TEST 6.0 LCD LIGHT NOTE : Minumum setup required for the system to run shall be Menu 1.0 and 4.0. If other menus are not set, they shall run according to default parameters. POWER UP Upon powering for the first time, the unit shall display introduction wordings in running mode. The green and red LEDs shall lit in sequence indicating sequence of initialisation. TO SETUP To begin programming, press, hold and release MENU button, and the SETUP menu shall be displayed. Initializing... LS4600 VER: X.XX < denotes PRE denotes NEXT and [] as AMPERES ELEC. S/B LINE SUPERVISORY 1.0 SETUP PAGE 5
6 1.0 Setup Menu There are 2 modes of operation available : Basic and Advance. In Basic setup mode, LS4600 shall detect the circuit for Open and Short only. The timing of detection shall depend on the intervals set in Auto Detection mode, ( Refer to Auto Test section ). Follow the steps below to use this mode. BASIC SETUP PRE to Menu SETUP NEXT to Menu BASIC SETUP Use < or to toggle between Basic and Advance Setup Accept? Accept OK 1.2 BP ON FAULT <ON CH.# * Default <ON Back to Menu 1.0 Press < or to accept the value of status. PRE MENU PRE Accept?/Bypass? 1.2 BP ON FAULT <OFF CH.# NEXT Imp xxxx NEXT Press < or to switch channel number. Bypass? Bypass OK * Imp xxxx Channel bypass mark * Press and PRE or NEXT key for setting up remaining channels or MENU to return to previous menu. BP = Bypass Use PRE or NEXT keys to select the required channel. Imp value shall be shown, otherwise OPEN or SHORT shall appear. Press to proceed to the next setting for the selected channel. A channel with or without value can be bypassed from surveillance or accepted for monitoring. Select PRE to accept for monitoring or NEXT to bypass. In BASIC Mode Hi and Lo function will be disabled, only OPEN and SHORT monitoring available. To enable Hi and Lo function use ADVANCE setup in menu 1.0 (SETUP) The ' * ' symbol will show when the value measured is out of preset range of Hi and Lo limits. Short or Open condition is self explainatory. A fault condition shall have red LED lit and vice versa. PAGE 6
7 1.0 Setup Menu ADVANCE SETUP 1.0 SETUP 1.0 SETUP ADVAN SETUP Imp xxxx Accept? / Bypass Accept Accept OK Bypass Bypass OK On selected set High-limit 1.2 BP ON FAULT <ON CH.# 1.3 H-LIMIT +## Imp xxxx To select Bypass or On upon fault detection * Imp xxxx Channel bypass mark * On selected set Low-limit 1.4 L-LIMIT -## Imp xxxx 1.5 EXIT? Y?/N? Use PRE or NEXT keys to select the required channel. Imp value shall be shown, otherwise OPEN or SHORT shall appear. Press to proceed to the next setting for the selected channel. A channel with or without value can be bypassed from surveillance or accepted for monitoring. Select PRE to accept for monitoring or NEXT to bypass. The preselected values for high limit and low limits are from 00 ohm to 500 ohm, with incremental of 20 Ohms. We recommend 50 % higher or lower values to avoid unnecessary false triggering. Once the required value is selected, press to proceed to the next sub menu. PAGE 7
8 2.0 Manual Test PRE to Menu 1.0 PRE to Menu MANUAL TEST Press NEXT to Menu Hixxxx CH# Imp XXXX < or to select Ch number and check impedance To Sub Menu 2.0 MENU 2.2 EXIT O< < or to select Yes or No To Sub Menu 2.0 YES NO To Sub Menu 2.1 Use this function to test speaker line impedance of each channel. Please note that the value shown are approximated figure. To obtain the actual value, use a dedicated Impedance Measurement meter. 3.0 Mem. Recall 3.0 MEM RECALL O< Press NEXT to Menu CH#=xxxx H=xxxx L=xxxx # Use PRE or NEXT keys to select channel number This menu enable the user to view the values of impedance of selected channels, which had been accepted earlier during setup (Menu 1.0). To clear the memories, use the MEMORY Menu (Menu 7.0) and all previously stored values and settings shall be erased. PAGE 8
9 4.0 Auto Test PRE to Menu AUTO TEST O< Press NEXT to Menu SELECT TIMER O< Test Seq=off # Use < or to select Auto or Manual mode If Off is selected Return to Submenu 4.0 If NO is selected 4.2 AT.TEST ON? O< Y?/N? Return to Submenu 4.0 Menu If a test interval is selected (from 1 min to 24 hours). By default, auto mode is set to off. Use < or key to select time. LS4600 VX.XX[SPEAKER LINE SURVEILLANCE] <<Auto Test xxh:xxm:xxs<<-remaining..<xxx Press < or to select ON or OFF for Auto Test. If Auto Test is ON The test sequence is started and repeated at the preset interval. Remainning time for the next sequence is displayed. This menu must be accessed for first time programming, in which shall determine how the unit shall run, either manually or automatically. If SELECT TIMER mode is selected, testing interval time should be entered, otherwise, the default timer is set to off. Once timer has been entered and auto mode selected, the unit shall immediately start testing sequence and the counter began from then onwards. To access to the main menu again, press Menu key 5.0 Buzzer PRE to Menu BUZZER Press NEXT to Menu KEY BEEP 5.2 FAULT BUZZER Press < or to select ON / OFF for key select. Press < or to select ON / OFF whenever fault is detected. Return to Buzzer Menu Buzzer is available for button pressing and alert / fault signal. This feature can be turned off to fit to ones' preference. For fault alert buzzer, if this is switch on, the Buzzer LED shall not lit when a failure is detected. If the buzzer is switched off, the buzzer LED and the correspondence channel fault LED shall lit. PAGE 9
10 6.0 LCD Back Light This menu provides the option to turn ON or OFF the LCD back light. PRE to Menu LCD BACK LIGHT Press NEXT to Menu LCD LIGHT Press < or to switch ON or OFF Back Light for LCD display. Return to LCD Back Light Menu 7.0 Memory PRE to Menu MEMORY 7.0 MEMORY O< SAVE? Save < Press NEXT to Menu 1.0 < or to reset or save the memory and press Enter Select < or to save / No 7.1 MEMORY SAVE O< Y?/N? 7.0 MEMORY O< RESET? < or to select Return to Memory Menu If earlier settings are to be wiped off, use this memory reset and the system shall return to default. After completing all channel setting, the changed parameters MUST be saved. DC power to the unit can be switched off when system is not in use. Settings shall be retained in the memory. PAGE 10
11 Summary Of Features 6 channel speaker line monitoring and expandable Basic and Advance level of detection setup Detection of faulty cable and speaker in individual zone or circuit Impedance measurement method - no capacitor coupling required and cable branching allowed. Faulty circuit disconnection option Built in impedance meter, range within 10 Ohm to 10 K Ohm LCD display to facilitate system setup, measurement and monitoring Fault alert with LED indicators and switchable buzzer Detection test interval setting from 1 min to 48 hours Short burst test signal, minimizing interruption to PA operation User setting for detection sensitivity for open, short and leakage Aux 24V DC output for volume controller overriding during testing mode Technical Specifications Operating voltage 24V DC via PS9400 PSU Power consumption 3.5W Capacity 6 channel and expandable Processor PIC micro controller with 12 bit ADC Impedance detection range 10 to 10 K Ohm Power measurement range 3 to 1000W 100V line Measurement accuracy +/- 3% within range Pilot tone injection frequency 1 KHz Pilot tone signal output level 5V sine Transmittal detection period 3 seconds per channel Detection interval User preset from 1 min to 48 hrs Sensitivity setting User preset at each channel Indicators - LED Normal, Fault, Buzzer, Auto run Display LCD 2 x 16 characters w back light Audible output signal Continuous buzzer with Off option Dry contact setting 3A DC output in detection mode 24V DC for individual channel Dimensions (WxHxD) 482 x 44 x 180 mm Weight 2.3 kg Note: The above specifications are correct at time of printing but subjected to changes without prior notice due to product improvements. PAGE 11
12 Warranty Conditions Only Amperes Electronics Service Centres are allowed to make warranty repairs : a list of Amperes Electronics Service Centres may be asked for by the purchaser or send directly to Amperes Electronics Sdn Bhd at 70 Jalan Industri PBP 3, Tmn Perindustrian Pusat Bandar Puchong, 47100, Puchong, Selangor, Malaysia or its authorized master distributor, TNT Links Sdn Bhd / MyPA Systems Sdn Bhd. This warranty is not valid if repairs are performed by unauthorized personnel or service centres. This warranty covers only repairs and replacement of defective parts ; cost and risks of transportation as well as removal and installation of the product from the main system are for the account of the purchaser. This warranty shall not extend to the replacement of the unit. This warranty does not cover damages caused by misuse, neglect, accident of the product as well as using the product with power supply voltage other than shown on the product, or any other power supply source / adaptor not recommended by the manufacturer. This warranty does not cover damages caused by fire, earthquakes, floods, lightning and every cause not directly related to the unit. This warranty does not include any indemnity in favor of the purchaser or the dealer for the period out of use of the unit; moreover the warranty does not cover any damages which may be caused to people and things when using the product. This warranty certificate is valid only for the described product, and is not valid if modifications are made on this certificate or on the identification label applied on the product. This warranty covers all the material and manufacturing defects and is valid for a period of 12 months from the date of purchase or for a longer period in countries where this is stated by a national law. In this case, the extension is valid only in the country where the product is purchased. Amperes Electronics Sdn Bhd is not obliged to modify previously manufactured products under warranty if the design changes or improvements are made. Disclaimer Information contained in this manual is subject to change without prior notice and does not represent a commitment on the part of the vendor. AMPERES ELECTRONICS SDN BHD shall not be liable for any loss or damages whatsoever arising from the use of information or any error contained in this manual. It is recommended that all services and repairs on this product be carried out by AMPERES ELECTRONICS SDN BHD or its authorized service agents. AMPERES series must only be used for the purpose they were intended by the manufacturer and in conjunction with this operating manual. AMPERES ELECTRONICS SDN BHD cannot accept any liability whatsoever for any loss or damages caused by service, maintenance or repair by unauthorized personnel, or by use other than that intended by the manufacturer. ISO 9001: 2008 Design & Manufacture of Public Address Equipment and Systems Certificate No / A / 0001 / UK / En AMPERES ELECTRONICS SDN BHD MADE IN MALAYSIA Published : March 2015
MP1020 INSTRUCTION MANUAL. Thank you for choosing another quality product from Amperes Electronics. 2 CH Media Player
INSTRUCTION MANUAL 2 CH Media Player DUAL CHANNEL DIGITAL MEDIA PLAYER MP 1020 CH 1 CH 2 a m pe re s Thank you for choosing another quality product from Amperes Electronics. is a newly added product, which
More informationipx5101 INSTRUCTION MANUAL Thank you for choosing another quality product from Amperes Electronics. Ethernet Paging Server
INSTRUCTION MANUAL ipx5101 Ethernet Paging Server ipx 5101 amperes ETHERNET PAGING SERVER ACT STATUS REM POWER Thank you for choosing another quality product from Amperes Electronics. ipx5101 is an upgraded
More informationipx5300 INSTRUCTION MANUAL Thank you for choosing another quality product from Amperes Electronics. Ethernet Music Client NEW
INSTRUCTION MANUAL ipx5300 Ethernet Music Client NEW EHTET ADDRESS ipx 5300 ET MUSIC CLIENT BALANCED LINE OUTPUT ET Thank you for choosing another quality product from Amperes Electronics. Amperes ipx
More informationPS8 - II. Professional Power Sequencer. User s Manual
PS8 - II Professional Power Sequencer User s Manual IMPORTANT SAFETY INSTRUCTIONS READ FIRST This symbol, whenever it appears, alerts you to the presence of uninsulated dangerous voltage inside the enclosure.
More informationV-9908 MESSAGE/PAGE PANEL
Issue 4 V-9908 MESSAGE/PAGE PANEL Introduction These instructions contain the specifications and guidelines necessary to install, operate, and maintain the V-9908, /Page Panel. The V-9908 /Page Panel provides
More informationVIPEDIA-12. Cameo specification sheet. Product Description
Product Description Pro-Sound quality Two RJ45 Ethernet IP ports 12 analogue audio inputs 12 dual A&B analogue audio outputs 20dB outputs for intelligent speakers Advanced energy management 30 minutes
More information2-Way Wireless I/O Expander Installation Guide
2-Way Wireless I/O Expander Installation Guide For more detailed information please refer to the iconnect Installer Manual provided on our website: www.electronics-line.com Table of Contents 1. Introduction...
More informationWARNING: Do not use the thermometer/data logger before you read the users manual and the following instructions.
55 This unit passes the following tests EN 61326-1:2006 (CISPR11,IEC/EN 61000-3-2:2006, IEC/EN 61000-3-3: 1995+A1 :2001+A2:2005 IEC/EN 61000-4-2/-3/-5/-6/-11) WARNING: Do not use the thermometer/data logger
More informationRangerBOSS Network Ready Constant Monitor Model CM2800
RangerBOSS Network Ready Constant Monitor Model CM2800 Instruction Manual Contents 1 Description CM2800 1 Features 1 2 Installation Installation Instructions 2 Installation Diagram 3 3 Operation Wrist
More informationLCD62. Keypad. User Manual
LCD62 Keypad User Manual Disclaimer: While every effort has been made to ensure that the information in this manual is accurate and complete, no liability can be accepted for any errors or omissions The
More informationHEX. User s Manual.
HEX User s Manual www.voodoolab.com Copyright 2014-2017 by Digital Music Corporation. This publication is protected by copyright and all rights are reserved. Voodoo Lab, Pedal Power, Ground Control and
More information1081R Remote Mic-Line Rack
1081R Remote Mic-Line Rack User Guide Issue 7.3 - for - Pro Tools control 88R control Standalone control Remote control The 1081R is a front end microphone pre-amplifier, using amp circuitry similar to
More informationINSTRUCTION MANUAL. Model Dual Input RTD Thermometer. Measures two temperatures simultaneously. Dual RTD probe inputs
INSTRUCTION MANUAL Model 421504 Dual Input RTD Thermometer Measures two temperatures simultaneously Dual RTD probe inputs Clock and Elapsed Timer functions Special functions include Data Hold, MIN/MAX/AVG,
More informationKramer Electronics, Ltd. USER MANUAL. Model: RC-BT1 / BT-1. Bluetooth controller
Kramer Electronics, Ltd. USER MANUAL Model: RC-BT1 / BT-1 Bluetooth controller Contents Contents 1 Introduction 1 2 Getting Started 1 3 Overview 1 3.1 Your BT-1 Bluetooth controller 2 4 Using the Bluetooth
More informationK44 Code lock. Technical manual
K44 Code lock GB Technical manual Copyright 2002 Bewator AB, Solna, Sweden. Material from the K44 Technical manual may only be copied with the consent in writing of Bewator. Bewator reserves the right
More informationWR-5e Remote Control
1. Introduction WR-5e Remote Control The WR-5e is a microprocessor based serial data remote control unit for Ashly NE or NX products. Compatible products currently include Pema amplifiers, ne8800 and ne4800
More informationSK-1011-SQ Digital Access Keypad with 5A Relay Output
User Operation for the SK--SQ. Using the User Codes: A. User codes operate the door (4-8 digits long). Press u u u u B. The key must also be pressed if the keypad is in manual-entry mode. Press u u u u
More informationIndoor/Outdoor Proximity Reader and Keypad with 10cm (4in) Read Range
Indoor/Outdoor Proximity Reader and Keypad with 10cm (4in) Read Range Stand alone CR-R885-SB Installation and Operating Instructions V1.1 TABLE OF CONTENTS Installation... 2 Mounting and Wiring... 2 Mounting
More informationTelephone Line Monitor USER GUIDE
Telephone Line Monitor USER GUIDE For Technical Assistance call the Manufacturers direct Ph 800 530 8645 8AM - 5PM West Coast Pacific Time NATCOMM USA LLC Responsible Supplier Code NC OPERATION Our Telephone
More informationCantata m100 Amplifier
Cantata m100 Amplifier Getting Started Guide www.resolutionaudio.com +1.415.553.4100 Safety Information CAUTION RISK OF ELECTRICAL SHOCK DO NOT OPEN CAUTION: TO REDUCE THE RISK OF ELECTRICAL SHOCK, DO
More informationAirTest Model CN9000 Series Sensor Controller
AirTest Model CN9000 Series Sensor Controller AirTest Model CN9000 Series Sensor Controller THEORY OF OPERATION A basic CN9000 configuration consists of Input/Process/Display combination modules, a 3 relay
More informationAC-115 Compact Networked Single-Door Controller Hardware Installation and Programming
AC-115 Compact Networked Single- Controller Hardware Installation and Programming Copyright 2013 by Rosslare. All rights reserved. This manual and the information contained herein are proprietary to REL,
More informationTanTime Systtem Timer Operation Instructions
TanTime Systtem Timer Operation Instructions For Software Revisions 4.3 & 4.4 Digital Tanning Bed Timer Control Systems for Complete Salon Control Page 1 of 29 DOC443 Rev 1 Contents Manufacturers Statement...
More informationENFORCER SK-1131-SQ. Digital Access Keypad with 5A Relay Output MANUAL. Digital Access Keypad Manual. Also available from SECO-LARM: Outdoor Keypads
User Operation for the SK--SQ Note: n n n nindicates. Using the User Codes: A. User codes operate the door (4-8 digits long). the inhibit code. Note: u u u uindicates Press u u u u the user code. B. The
More informationOPERATING INSTRUCTIONS PA AMPLIFIER P-1812
OPERATING INSTRUCTIONS PA AMPLIFIER P-1812 Please follow the instructions in this manual to obtain the optimum results from this unit. We also recommend that you keep this manual handy for future reference.
More informationAshly WR-5 Remote Control
1. Introduction Ashly WR-5 Remote Control The WR-5 is a microprocessor based serial data remote control unit for Ashly NE or NX products. Compatible products currently include Pema amplifiers, ne8800 and
More informationIntegrating Sound Level Datalogger Model
User's Guide Integrating Sound Level Datalogger Model 407780 Introduction Congratulations on your purchase of the Extech 407780 Integrating Sound Level Meter. The 407780 with programmable integrating time
More informationDAS 250L CONTROL COMMUNICATOR INSTALLATION MANUAL
DAS 250L CONTROL COMMUNICATOR INSTALLATION MANUAL TABLE OF CONTENTS 1. GENERAL DESCRIPTION... P.2 2. STANDARD AND OPTIONAL PARTS LIST..... P.2 3. FEATURE DEFINITIONS... P.3 4. TERMINAL DRAWING AND SPECIAL
More informationARTiPRO. User Manual. (Model 910 & 920)
ARTiPRO User Manual (Model 910 & 920) www.rtihub.com Main Keys & Interfaces 1. Main LCD display 2. / button 1 2 3 4 5 8 6 3. button 4. / button 5. Power & Alert LED 6.
More informationCarefree-Security. Installation and programming instructions 1050A. Owner s Manual
Carefree-Security Heavy Duty Commercial - Industrial Fully Sealed Digital Access Keypad Specially Designed for Gate Operators, Overhead Doors, Specialty Doors & Electric Door Locking Devices SINGLE OR
More informationVP Process Inc. Model: VP-EC-RDU Modbus RTU LCD Display
VP Process Inc. Model: Modbus RTU LCD Display User Manual Ver: 2.0 Aug. 2017 P a g e 1 Standard Features Low Power (12-24 VDC) 2.1 x 5mm Barrel Plug, RJ45 and Terminal Block Input On-Board Local Temperature
More informationMCCB-250 MOLDED-CASE CIRCUIT BREAKER TESTER
MCCB-250 MOLDED-CASE CIRCUIT BREAKER TESTER USER S MANUAL Vanguard Instruments Company, Inc. 1520 S. Hellman Ave. Ontario, California 91761, USA TEL: (909) 923-9390 FAX: (909) 923-9391 January 2015 Revision
More informationOperating Manual. Micro-Ohmmeter VG-CS200 VG-CS300 VG-CS400 VG-CS600
Operating Manual Micro-Ohmmeter VG-CS200 VG-CS300 VG-CS400 VG-CS600 Warranty Mostec AG warrants this product to be free of manufacturing defects for a 2-year period after the original date of purchase.
More informationTVA2.1 2-Channel Digital Amplifier Installation Manual
TVA2.1 2-Channel Digital Amplifier Installation Manual SAFETY INSTRUCTIONS WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE. CAUTION: TO REDUCE THE
More informationU-150 Integrated Amplifier User s guide
U-150 Integrated Amplifier User s guide U-150 Integrated Amplifier User s guide Specifications: Contents: Output: Phono: Line: Digital: Volume control: Dimensions: Weight: 2 300W/8 Ohm, 2 600W/4 Ohm Distortion:
More informationVELOCITY POWER CLASS D AMPLIFIER with DSP MP 68A
VELOCITY POWER CLASS D AMPLIFIER with DSP MP 68A Operating and Installation Instructions CAUTIONS This device has been manufactured according to established safety guidelines. However, dangers may still
More informationINTELLIGENT DOCKING STATION USERS MANUAL
Kodiak Mobile by Jotto Desk 209 W. Easy St., Rogers, AR USA 72756 Customer Service: 877.455.6886 http://www.kodiakmobile.com PART NUMBER: 450-4011 - Last Update: 06.2009 INTELLIGENT DOCKING STATION USERS
More informationUser's Guide. Programmable DC Power Supply 200 Watt (40 Volts / 5 Amps) Model Introduction
User's Guide Programmable DC Power Supply 200 Watt (40 Volts / 5 Amps) Model 382280 382280 Introduction Congratulations on your purchase of the Extech 382280 Programmable DC Power Supply. This 200 watt
More informationMA V 30W Mixer Amplifier Order code: CRAM02 MA V 60W Mixer Amplifier Order code: CRAM03 USER MANUAL
www.cleveracoustics.co.uk MA 130 100V 30W Mixer Amplifier Order code: CRAM02 MA 160 100V 60W Mixer Amplifier Order code: CRAM03 USER MANUAL WARNING FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY
More informationIntegriti User Manual. Elite / EliteX LCD Terminal Keypads
Integriti User Manual Elite / EliteX LCD Terminal Keypads INNER RANGE recommends that all INTEGRITI systems are installed & maintained by FACTORY CERTIFIED TECHNICIANS. For a list of Accredited Dealers
More informationMiT. MOVING image TECHNOLOGIES INSTRUCTIONS FOR INSTALLATION, OPERATION, AND MAINTENANCE
MiT MOVING image TECHNOLOGIES INSTRUCTIONS FOR INSTALLATION, OPERATION, AND MAINTENANCE OF A-LMS 24 Architectural Lighting Management System Part number A000230-xxx Manual Version 1.0 MOVING image TECHNOLOGIES,
More informationpoly-planar Marine Audio System
ME-52 Expansion Amplifier 1 ME-52 Expansion Amplifier Introduction: The ME-52 is a 2 channel audio amplifier capable of delivering up to 25W RMS per channel. It s compact, water resistant design allows
More informationModel P4470 Save A Watt Operation Manual
Model P4470 Save A Watt Operation Manual Thank you for purchasing the P4470 Save A Watt. This operating manual will provide an overview of the product, safety instructions, a quick guide to operation,
More informationUSER S MANUAL SWITCHER / LOOPER
SWITCHER / LOOPER Features: - Compact footprint: 18.90 (480mm) L x 2.36 (60mm) W x 2.05 (52mm) H - Instant recall (no latency). - True bypass design. - 8 loops in total, 7 series loops and 1 separate loop.
More informationX-618 Public Address and Voice
X-618 Public Address and Voice Alarm System Commissioning Manual M_XXXXXX_CN_0 Copyright 2012 Honeywell International Inc. All rights reserved. No part of this document may be reproduced in any form without
More informationProfessional Radio GM Series. Controlhead Service Information
Professional Radio GM Series Controlhead Service Information Issue: September 2000 ii Computer Software Copyrights The Motorola products described in this manual may include copyrighted Motorola computer
More informationModel #28599 Wireless Bluetooth Surround Bar & Subwoofer 285W
Model #28599 Wireless Bluetooth Surround Bar & Subwoofer 285W User manual & Safety Guide Thank you for choosing Pure Acoustics. We hope you enjoy each and every use of this product. We suggest that you
More informationV-9964 Digital Feedback Eliminator/Message Stacker
Issue V-99 Digital Feedback Eliminator/Message Stacker General Design The V-99 is designed to eliminate acoustic feedback and act as a message stacker. When a page is made, the message is digitized and
More informationP4472 Save A Watt HD Operation Manual
P4472 Save A Watt HD Operation Manual Thank you for purchasing the P4472 Save A Watt HD. This operating manual will provide an overview of the product, safety instructions, a quick guide to operation,
More informationDual Channel Active Direct Box. Artcessories. User's Manual
Dual Channel Active Direct Box Artcessories User's Manual IMPORTANT SAFETY INSTRUCTION READ FIRST This symbol, whenever it appears, alerts you to the presence of uninsulated dangerous voltage inside enclosure-voltage
More informationZonit μats TM Users Guide μats1-lv Version 1.2
Zonit μats TM Users Guide μats1-lv Version 1.2 Table of Contents Product Overview...2 Pre-Installation Considerations...2 Product Features...3 Installation...4 Optional Accessories...4 μats TM Operational
More informationMZ Line tester. Contents. Reference: Date: October Version: 3
Contents I. INTRODUCTION... 2 II. Terminology... 3 III. Presentation... 4 Front panel... 4 TOP OF THE CASE... 5 ACCESSORIES SUPPLIED... 5 IV. CAUTION... 6 V. Operation... 7 TURN on and off... 7 MAIN FUNCTIONS...
More informationAMP100 AMP102 AMP110 AMP210 AMP310
Amplifier Guide AudioSource AMP series amplifiers are designed for home and commercial audio distribution systems where high quality sound, flexibility, and reliability are essential. The AMP series offers
More informationDigital Sound Level Meter
User's Guide Digital Sound Level Meter Model 407732 Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 FAX 781.665.0780 - TestEquipmentDepot.com information. A Return Authorization
More informationINSTRUCTIONS FOR USE Pro-Ject Stereo Box DS
INSTRUCTIONS FOR USE Pro-Ject Stereo Box DS Dear music lover, thank you for purchasing a PRO-JECT AUDIO amplifier. In order to achieve maximum performance and reliability you should study these instructions
More informationSBW-175. Audio Soundbar & Subwoofer. Instructions Guide
SBW-175 Audio Soundbar & Subwoofer Instructions Guide Contents Controls And Functions... 1 What s In The Box?... 6 Instructions Guide...7 Connections... 8 Optional: Using a Optical Input... 9 Bluetooth
More informationNeutrik 20A powercon with 2nd order EMI filter & GDT/VDR protection circuit against Lightning Strike & Local Power Surge Circuit A
PDU16-AV 20A AC PDU WITH POWER MONITOR 2U Rack Mount PDU with Overload Protection & Power Monitoring 2U high Horizontal Mounting unit designed to provide versatile hook-up for the distribution of AC power
More informationSP-1800 OWNERS MANUAL
SP-1800 OWNERS MANUAL www.visionaudiovisual.com/techaudio/sp-1800 1 DECLARATION OF CONFORMITY Where applicable Vision products are certified and comply with all known local regulations to a CB Certification
More informationBASIC PA AMPLIFIER A-1031 A-1061 A-1121 OPERATING INSTRUCTIONS TABLE OF CONTENTS
OPERATING INSTRUCTIONS BASIC PA AMPLIFIER A-1031 A-1061 A-1121 Please follow the instructions in this manual to obtain the optimum results from this unit. We also recommend that you keep this manual handy
More informationMCCB-500 MOLDED-CASE CIRCUIT BREAKER TESTER
MCCB-500 MOLDED-CASE CIRCUIT BREAKER TESTER USER S MANUAL Vanguard Instruments Company, Inc. 1520 S. Hellman Ave. Ontario, California 91761, USA TEL: (909) 923-9390 FAX: (909) 923-9391 January 2015 Revision
More information212iL Rev. 1.1
212iL 1 International Electronics, Inc. 427 Turnpike Street Canton, Massachusetts 02021 212iL (illuminated Luxury) Keypad Single Unit Keypad- Control Installation Manual Features: 120 User Capability Illuminated
More informationUser's Guide. Model Noise Dosimeter with PC Interface. Introduction
User's Guide Noise Dosimeter with PC Interface Model 407355 Introduction Congratulations on your purchase of the Extech 407355 Personal Noise Dosimeter. The 407355 is designed to test noise exposure in
More informationModel 500 Digital Weight Indicator
Rev. 1.10 Serial Number: Model 500 Digital Weight Indicator USER MANUAL 1992-2000, Reliable Scale Corporation Reliable Scale Corporation 520 Moraine Road NE Calgary, Alberta, Canada Tel:1-800-419-1189
More informationMASELEC MTC-6 master transfer and monitor system
MASELEC MTC-6 master transfer and monitor system http://www.maselec.com/ Mases Electronics Ltd. Bishopswood, Cannon Hill Close, Bray, Berks SL6 2DH, England. Tel/Fax: +44 (0) 1628-770 104. E-mail: leif@maselec.com
More informationCompact USB Digital Speakers. Quick Start User Guide
Compact USB Digital Speakers Quick Start User Guide Quick Start User Guide is also available on our website: www.ultralinkproducts.com/ucube This product is intended for use solely with the USB and RCA
More informationDPN 4 Duo. User Manual. 4-Port Dual-Head DisplayPort 1.2 KVM Switch with USB 2.0 and Audio Sharing
DPN 4 Duo User Manual 4-Port Dual-Head DisplayPort 1.2 KVM Switch with USB 2.0 and Audio Sharing Access and Control Four Computers with 2 DisplayPort Monitors each Using One KVM Workstation with Two DisplayPort
More informationQuick Start Guide. ELPRO 905U-L Wireless I/O Receiver Unit. man_905u-l-r_quickstart_v1.9.doc
Quick Start Guide ELPRO 905UL Wireless I/O Receiver Unit man_905ulr_quickstart_v1.9.doc ELPRO 905UL Wireless I/O Receiver Unit Quick Start Guide About this document This document is the ELPRO 905UL Wireless
More informationMA V 60W Mixer Amplifier Order code: CRAM05 MA V 120W Mixer Amplifier Order code: CRAM06 USER MANUAL
www.cleveracoustics.co.uk MA 260 100V 60W Mixer Amplifier Order code: CRAM05 MA 2120 100V 120W Mixer Amplifier Order code: CRAM06 USER MANUAL WARNING FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY
More informationKodiak Mobile INTELLIGENT DOCKING STATION USERS MANUAL PART NUMBER: PANASONIC CF53 TOUGHBOOK COMPATIBLE AN ISO 9001:2008 CERTIFIED COMPANY
CUSTOMER SERVICE If you have any questions or require additional information please contact Customer Service at 877-455-6886, Monday though Friday, 8:00am - 5:00pm CST. TECHNICAL SUPPORT Kodiak Mobile
More informationAVC 2 AUTOMATIC VOLUME CONTROL USERS MANUAL
AVC 2 AUTOMATIC VOLUME CONTROL USERS MANUAL GENERAL DETAIL The AVC2 will control a stereo channel to a preset maximum output level allowing the maximum sound level of a system to be controlled. The AVC2
More informationCR6S Stereo Micro Crush
1 THANK YOU! Thank you for choosing Orange. You are now a member of the Legendary British Guitar Amplifier owners club! Since 1968 when the company was founded, Orange has been a pioneering force in the
More informationRFID: Read and Display V2010. Version 1.1. Sept Cytron Technologies Sdn. Bhd.
PR8-B RFID: Read and Display V2010 Version 1.1 Sept 2010 Cytron Technologies Sdn. Bhd. Information contained in this publication regarding device applications and the like is intended through suggestion
More informationOwners Manual: G-Tel 525(Wire-line)
Owners Manual: G-Tel 525(Wire-line) Getting started: 1. Connect the phone s RJ11 phone jack to the local telephone line. 2. Lift hand-set, listen for dial tone, LCD will display PLEASE DIAL. 3. Dial desired
More informationPWRguard PLUS Spring City Drive Waukesha, WI
PWRguard PLUS www.westmountainradio.com 1020 Spring City Drive Waukesha, WI 53186 262-522-6503 sales@westmountainradio.com 2016, All rights reserved. All trademarks are the property of their respective
More information_A_en_LED63VG VOICE GUIDE KEYPAD LED63VG
18020502_A_en_LED6VG VOICE GUIDE KEYPAD LED6VG Disclaimer While every effort has been made to ensure that the information in this manual is accurate and complete, no liability can be accepted for any errors
More informationTS-ADA-029. Wireless Tone Generator. User's Manual / Installation Guide. Version 1.03
TS-ADA-029 Wireless Tone Generator User's Manual / Installation Guide Version 1.03 Visiplex, Inc. 2012 TS-ADA-029 Wireless Tone Generator Copyright The product described in this manual includes copyrighted
More informationADVANCED 4/8-PORT SECURE KM SWITCH
ADVANCED 4/8-PORT SECURE KM SWITCH USM-2S0-1M0 REV: 1.1 DATE: 09/11/2017 1 2 3 4 SS4P-KM-U SECURE KM SWITCH 4 PORT W/ AUDIO MODELS: SS4P-KM-U SS4P-KM-UCAC SS8P-KM-U SS8P-KM-UCAC 4-Port Secure KM Switch
More informationADT-MP3. User Manual. User Manual. It is important to read this instruction book prior using your new product for the first time.
ADT-MP3 User Manual ADT-MP3 M MODE OFF MUTE 1 2 3 SCENE TIMER SENSOR 4 5 6 MUSIC LED DMX 7 8 9 MP3 FM PRESET User Manual All rights reserved. Improvement and changes to specifications, design and this
More informationMYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL
MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL VISIT OUR WEBSITE SIGMACONTROLS.COM MYR QLC MANUAL 013114 2 TABLE OF CONTENTS INTRODUCTION 3 Ordering Information Specifications Features WIRING
More informationVDI Pro Voltage & Dry Contact Interface Installation and programming Guide MODEL VDI MK2
VDI Pro Voltage & Dry Contact Interface Installation and programming Guide MODEL VDI MK2 1 of 18 PREFACE Important Installation Information It is the purchasers responsibility to determine the suitability
More informationKramer Electronics, Ltd. USER MANUAL. Model: VM-50AN. 1:5 Audio Distributor
Kramer Electronics, Ltd. USER MANUAL Model: VM-50AN 1:5 Audio Distributor Contents Contents 1 Introduction 1 2 Getting Started 1 2.1 Quick Start 1 3 Overview 3 4 Your Audio VM-50AN 1:5 Distributor 4 5
More informationOperating Instruction Manual POWERED MIXER. Model MX-401. Toa Electric Co., Ltd. KOBE, JAPAN
Operating Instruction Manual POWERED MIXER Model MX-401 Toa Electric Co., Ltd. KOBE, JAPAN Contents General Description Features Front Panel [Names of components & their usage] Rear Panel [Names of components
More informationINSTRUCTIONS FOR USE Pro-Ject Stereo Box S2 BT
INSTRUCTIONS FOR USE Pro-Ject Stereo Box S2 BT Dear music lover, thank you for purchasing this integrated amplifier from Pro-Ject Audio Systems. In order to achieve maximum performance and reliability
More informationDisplay Real Time Clock (RTC) On LCD. Version 1.2. Aug Cytron Technologies Sdn. Bhd.
Display Real Time Clock (RTC) On LCD PR12 Version 1.2 Aug 2008 Cytron Technologies Sdn. Bhd. Information contained in this publication regarding device applications and the like is intended through suggestion
More informationInstallation & Operation Guide
Installation & Operation Guide ADS 3120 Plus 120W ac/dc Mixer Amplifier PLEASE NOTE: THIS MANUAL AND THE NOTES CONTAINED HEREIN ARE COPYRIGHT AND MAY NOT BE REPRODUCED EITHER WHOLLY OR IN PART, IN ANY
More informationTABLE OF CONTENTS INTRODUCTION. 3. Analog Input Analog Output Digital Input Digital Output OPERATIONAL DESCRIPITON.. 7 PROGRAMMING AND INITIAL SETUP.
DIVERSIFIED HEAT TRANSFER SERIES 700 STEAM GENERATOR CONTROLLER INSTRUCTION MANUAL VISIT OUR WEBSITE AT SIGMACONTROLS.COM SERIES 700 DHT STEAM GENERATOR MANUAL 042514 2 TABLE OF CONTENTS INTRODUCTION.
More informationNote: Unit is set at the factory for 120V operation. Be sure to change the fuse. (2A rating) before switching to 230V operation.
Note: Unit is set at the factory for 120V operation. Be sure to change the fuse (2A rating) before switching to 230V operation. (2) FCC Statement 1. This device complies with Part 15 of the FCC Rules.
More informationIF ADDITIONAL INSTALLATION COMPONENTS ARE NECESSARY, CONTACT YOUR REI SALES REP FOR:
50W X 4 R-9 05 Thank you for purchasing this AM/FM/CD/MP3 Weather Band Receiver from REI. This product is designed and tested to withstand temperature and vibration extremes. Please read the owner's manual
More informationMeterBuilder MB-1 PROGRAMMABLE RF POWER METER. CIRCUIT DESCRIPTION Version 1.01 June 2011
MeterBuilder MB-1 PROGRAMMABLE RF POWER METER CIRCUIT DESCRIPTION Version 1.01 June 2011 Patent and Copyright Notices Patent Applied For Copyright Material in this document copyrighted 2011 FullWave, LLC.
More informationANC Series RS-422 Serial Communications Adapter
Rev. B $ 5.00 ANC - 6000 Series RS-422 Serial Communications Adapter Antona Corporation, Los Angeles, CA Antona Corporation (818)783-4299 FAX (818)783-4216 1 Antona Corporation Copyright Copyright (c)
More informationMULTI-PURPOSE SELF-CONTAINED DIGITAL ACCESS CONTROL KEYPAD
MULTI-PURPOSE SELF-CONTAINED DIGITAL ACCESS CONTROL PAD Programming & Installation Manual An Innovative Product Developed By: PROTECT - ON SYSTEMS LTD. MANUFACTURED BY: 20 R SINCE 1979 ADVANCED ELECTRONICS
More informationIntroduction & Features. Important Notes. Installation Steps
Navigation Unlock & Reverse Camera Input Interface for Chrysler/Dodge/Jeep/Ram Vehicles Rev. 051915 ***Only applicable to revision 1.1.2 firmware on BCI-CH21*** Class 2 J1850 VPW Arbitration J1850 Class
More informationEAR K. Installation and Programming. Manual
EAR 2000 4K Installation and Programming Manual EAR 2000 4K Installation and Programming Manual Release 1 Version 3 June 2011 NOTICE This publication refers to the EAR 2000, Release 3. Additional copies
More informationAAD USER GUIDE. For Technical Assistance Please Phone: (07) October 2016
AAD USER GUIDE October 2016 For Technical Assistance Please Phone: (07) 5596 5128 PRODUCT DESCRIPTION Our AAD AUTOMATIC ANNOUNCEMENT DEVICE is designed to automatically process incoming telephone calls,
More informationOperating Instructions KEYPAD. Compatible WIRELESS ACCESS CONTROL
Operating Instructions KEYPAD Compatible WIRELESS ACCESS CONTROL Contents Technical specifications page 1 Approvals page 1 Changing the Master code page 2 Adding a User code page 3 Deleting a User code
More informationVM SERIES Rackmount 100V mixer-amplifiers
VM SERIES Rackmount 100V mixer-amplifiers VM60, VM120, VM240Z Caution: Please read this manual carefully before operating Damage caused by misuse is not covered by the warranty Introduction Thank you for
More informationVIP-804 QUAD ENHANCED NETWORK AUDIO PORT
ISSUE 6 VIP-804 QUAD ENHANCED NETWORK AUDIO PORT INTRODUCTION The VIP-804 Quad Enhanced Network Audio Port enables voice access to four zones of one-way paging over an IP network, allowing page zones to
More informationPRe6. Multi-Channel Analog Pre-Amplifier
User's Guide and Warranty Information PRe6 Multi-Channel Analog Pre-Amplifier Bel Canto Design, LTD. 212 Third Avenue North Minneapolis, MN 55401 Phone: (612) 317.4550 Fax: (612) 359.9358 www.belcantodesign.com
More informationMEGAMOUTH MK3 Portable PA System
MEGAMOUTH MK3 Portable PA System Introduction Thank you for choosing the Megamouth portable PA unit. This product has been designed to provide convenient sound reinforcement for teaching, demonstrations
More informationSK18A. 18 Pins PIC START-UP KIT. User s Manual V1.1. Dec 2007
SK18A 18 Pins PIC START-UP KIT User s Manual V1.1 Dec 2007 Information contained in this publication regarding device applications and the like is intended through suggestion only and may be superseded
More information