1 Specifications - hapter Terminal ases and Power Supplies In This hapter: TK-0(-) I/O Terminal ase... TK-(-) I/O Terminal ase... TK-0, TK-0 Power Supply... alculating the Power udget... Managing the Power Resource... Power Supply Specifications... Module Power Requirements... Power udget alculation Example...

2 0 TK-0(-) I/O Terminal ase Specifications Specification TK-0 TK-0- Terminal Type Screw type Spring clamp type Recommended Torque Recommended Screwdriver lade Size Wire Gauge Size.. lb in (0. 0. N m) 0.0 in. X 0. in. (0. mm X.0 mm) Solid conductor: WG Stranded conductor: WG* Weight g g *Twist stranded conductors before inserting into gate. TK-(-) I/O Terminal ase Environmental Specifications mbient Operating Temperature!F to!f (0! to!) Storage Temperature -!F to!f (-0! to 0!) mbient Humidity % to % (Non-condensing) tmosphere No corrosive gases. The level of environmental pollution = (UL 0). Vibration Resistance MIL ST 0. Method. Shock Resistance MIL ST 0. Method. Voltage Withstand 00V, minute Insulation Resistance 00V, 0Mq NEM IS-0 Noise Immunity Impulse Noise es, 000V F class RFI (MHz, 0MHz 0W, 0cm) gency pprovals UL E, E, F class N/ Push in on clamp using screwdriver blade size: 0.0 X 0. in. to 0.0 X 0. in. (0. mm X mm to 0. mm X mm) Solid conductor: WG Stranded conductor: WG* Specifications Specification TK- TK-- Terminal Type Screw type Spring clamp type Recommended Torque Recommended Screwdriver lade Size Wire Gauge Size.. lb in (0. 0. N m) 0.0 in. X 0. in. (0. mm X.0 mm) Solid conductor: WG Stranded conductor: WG* Weight 0g 0g *Twist conductors before inserting into gate. N/ Push in on clamp using screwdriver blade size: 0.0 X 0. in. to 0.0 X 0. in. (0. mm X mm to 0. mm X mm) Solid conductor: WG Stranded conductor: WG* o-more TH Series PL Hardware User Manual, st Edition, Rev. - TH-M-M

3 TK-0, TK-0- TK-, TK-- 0 o-more TH Series PL Hardware User Manual, st Edition, Rev. - TH-M-M

4 0 TK-0, TK-0 Power Supply Specifications Specification TK-0 TK-0 Input Voltage Range 0/0 V ( V) / V (0.. V) Input Frequency 0/0 Hz ( Hz) - Maximum Power 0V 0W Maximum Inrush urrent 0 0 Insulation Resistance 00V Voltage Withstand (ielectric) 00V between primary, secondary and field ground uxiliary V Supply 00m maximum - Output : Voltage. V (.00.0 V). V (.00.0 V) V a).0 maximum urrent ase Power b). maximum (see note).0 maximum Supplied Ripple % maximum % maximum Output : Voltage V (0.0.0 V) - V a) 00m maximum urrent ase Power b) 00m maximum (see note) - Supplied Ripple 0% maximum - Replacement Terminal lock - Phoenix ontact MVSTW./-ST-.0 K MVSTW./-ST-.0 K Fuse (Primary) not replaceable NOTE: V is achieved by lowering the V to. from.0. Environmental Specifications mbient Operating Temperature!F to!f (0! to!) Storage Temperature -!F to!f (-0! to 0!) mbient Humidity % to % (Non-condensing) tmosphere No corrosive gases. The level of environmental pollution = (UL 0). Vibration Resistance MIL ST 0. Method. Shock Resistance MIL ST 0. Method. Voltage Withstand 00V, minute Insulation Resistance 00V, 0Mq NEM IS-0 Noise Immunity Impulse Noise es, 000V F class RFI (MHz, 0MHz 0W, 0cm) o-more TH Series PL Hardware User Manual, st Edition, Rev. - TH-M-M

5 00-0V 0-0Hz 0V (L).0-.0V 0W (N) + _ +V _OUT LG LG G G TK-0 TK-0 PULL TO UNLOK PULL TO UNLOK TK-0 TK-0 Power Supply # TK-0L ase Expansion able Power Supply # Note: Use the TK 0 V auxiliary supply or an external user supply for modules that require an external V. Important Power udget Note: For each power supply in a system make sure the current required by the PU and I/O modules does not exceed the current supplied at both V and V (if using the V auxiliary supply). o-more TH Series PL Hardware User Manual, st Edition, Rev. - TH-M-M 0

6 TH-ME TERM RUN RUN STOP US I/O TX ERR RX US PGM PORT 0 alculating the Power udget Managing the Power Resource When determining the types and quantity of I/O modules to be used in the o-more TH Series PL system, it is important to remember there is a limited amount of power available from the power supply. chart is provided to help you easily see the amount of power available with and power supplies. t the end of this section you will also find an example of power budgeting and a worksheet showing sample calculations. If the chosen I/O exceeds the maximum power available from the power supply the problem is corrected by simply adding another power supply. WRNING: It is extremely important to calculate the power budget correctly. If you exceed the power budget, the system may operate in an unpredictable manner which may result in a risk of personal injury or equipment damage. Power Supply Specifications The following chart shows the amount of current supplied by the Terminator I/O power supply. Use this to calculate the power budget for your system. The uxiliary V Power Source mentioned in the table can be used to power field devices or modules that require an external V. Power Supply Note max. of V can be achieved by lowering the V to 00m. Power Supply # V urrent Supplied in m (Internal) uxiliary V Power Source urrent Supplied in m TK TK-0 (see Note) Power Supply V urrent uxiliary Supplied in m V Power (Internal) Source urrent Supplied in m TK Power Supply # NOTE: Important about Power Supplies - One power supply is required in the leftmost component position (Power Supply #), as shown above. dditional power supplies should be added between I/O modules as necessary to meet power budget requirements. Each power supply powers the modules to its right, but is interrupted by the next power supply. It is not mandatory to have a power supply in the leftmost position on an expansion rack. The system shown above: Power Supply # powers the PU module and the two I/O modules to its right. Power Supply # powers the remaining five I/O modules. This is only an example and the power budget requirements vary depending on the I/O modules used. o-more TH Series PL Hardware User Manual, st Edition, Rev. - TH-M-M

7 Module Power Requirements This chart shows the amount of maximum current required for each of the o-more TH PL modules. Use this information to calculate the power budget for your system. If an external V power source is required, you can use the built-in V auxiliary supply as long as you do not exceed the power budget. If any device is connected to the ontroller s serial port that uses the V supply pin, be sure to include the device s power consumption in your V power budget calculation. Terminator Module Power onsumption Module V (m) V (m) Module V (m) V (m) PU Modules nalog Input Modules TH-M 0 0 TF-0-0 (see note ) TH-ME 0 TF-- 0 (see note ) Input Modules TF-0-0 (see note ) TK-0N 0 TF-- 0 (see note ) TK-N 0 0 TF-RT TF-TMST 0 0 Input Modules TF-THM 0 0 (see note ) TK-0N- 0 nalog Output Modules TK-N- 0 0 TF-0-0 (see note ) Output Modules TK-0T (see note ) TF-- 0 (see note ) TK-0T TH-0TS 00 0 TF-0-0 (see note ) TK-T (see note ) TK-T TF-- 0 (see note ) Output Modules ombination nalog Modules TK-0T (see note TF-- TK-T 0 0 and ) TK-0TS 00 0 Relay Output Modules TF-- 0 (see note ) TK-0TR 0 0 Specialty Module and other devices TK-TR 00 0 TK-0TRS 00 0 Note : Use TK-0 V auxiliary supply or external user supply. Note : 0m plus 0m per output loop. TH- TRIO 00 0 NOTE: Important Power udget - For each power supply in a system, make sure the current required by the PU module and I/O modules does not exceed the current supplied at both V and V. 0 o-more TH Series PL Hardware User Manual, st Edition, Rev. - TH-M-M

8 0 Power udget alculation Example The following example shows how to calculate the power budget for a o-more TH Series PL system. PL Power Supply # Part Number V (m) V (m) Required Required Power Supplied TK PU TH-ME 0 Module TK-N- 0 0 Module TK-T 0 0 Maximum power required 0 Remaining power available 000- = = 00 Power Supply # Part Number V (m) V (m) Required Required Power Supplied TK Module TK-0-0 Module TK-0-0 Module TK-T Module TK-0TR 0 0 Module TK-0N 0 Maximum power required 00 Remaining power available 00- = = 0 (see note ) Note : n external user power supply must be used if the V current requirement exceeds the TK-0 V auxiliary supply.. Fill in the information for the PU, I/O modules, and any other devices that will use system power, including devices that use the V output. evices which fall into the Other category are devices such as an operator interface which also has power requirements but do attach as a module to the system.. dd the current columns starting with the PU and put the total in the row labeled Maximum power required.. Subtract the row labeled Maximum power required from the Power Supplied. Place the difference in the row labeled Remaining Power vailable.. If Maximum Power Required is greater than Power Supplied in either of the two columns, the power budget will be exceeded. It will be unsafe to use this configuration and you will need to restructure your configuration. o-more TH Series PL Hardware User Manual, st Edition, Rev. - TH-M-M

Analog Voltage Combination Module

Analog Voltage Combination Module Analog Voltage Combination Module T1F-8AD4DA-2 8-channel analog voltage input 4-channel analog voltage output The combination 8-in and 4-out voltage module uses a T1K-8B or T1K-8B-1 base, which is purchased

More information

Chapter. Specifications. In this Chapter...

Chapter. Specifications. In this Chapter... Specifications hapter In this hapter... vailable Models... - E-SML-RN and E-SML-R Specifications... - E-SML and E-TL Specifications... - E-TL, E-TL and E-TL Specifications... - E-SML-RN, E-SML-R, E-SML

More information

T1H-EBC. Communications 10Base-T Ethernet 100Base-T Ethernet Data Transfer Rate 10 Mbps 10/100 Mbps Link Distance. Ethernet Protocols

T1H-EBC. Communications 10Base-T Ethernet 100Base-T Ethernet Data Transfer Rate 10 Mbps 10/100 Mbps Link Distance. Ethernet Protocols Ethernet Networking T1H-EBC T1H-EBC100 The T1H-EBC(100) modules provide a low-cost, high-performance Ethernet link between Terminator I/O and your PC-based control or Win/ DL205/DL405 CPUs using the H*-ERM

More information

Chapter. F2-02DA-1, F2-02DA-1L 2-Channel Analog. Current Output. In This Chapter...

Chapter. F2-02DA-1, F2-02DA-1L 2-Channel Analog. Current Output. In This Chapter... F-0-, F-0-L -hannel nalog hapter urrent In This hapter... Module Specifications onnecting and isconnecting the Field Wiring Module Operation Writing the ontrol Program 0 Module Specifications - The F-0-

More information

Chapter. F0-04AD-2, 4-Channel Analog Voltage Input. In This Chapter...

Chapter. F0-04AD-2, 4-Channel Analog Voltage Input. In This Chapter... F0-0-, -hannel nalog Voltage Input hapter In This hapter... Module Specifications... Setting the Module Jumpers... onnecting and isconnecting the Field Wiring... Wiring iagram... Module Operation... Special

More information

Installation and Setup. In This Chapter... Installing the H0 PSCM The Profibus Network Configuring the Module

Installation and Setup. In This Chapter... Installing the H0 PSCM The Profibus Network Configuring the Module Installation and Setup 1 2 In This Chapter.... Installing the H0 PSCM The Profibus Network Configuring the Module 2 2 Installing the H0 PSCM Remove the Slot Cover The first step in installing the option

More information

Installing the H2 -EBC(100), H2 -EBC -F or H4 -EBC( -F)

Installing the H2 -EBC(100), H2 -EBC -F or H4 -EBC( -F) 12 Installing the H2 -EBC(100), H2 -EBC -F or H4 -EBC( -F) In This Chapter Network Identifiers Setting the Module ID The H2 Series EBC DIP Switch The H4 Series EBC DIP Switch Inserting the H2 Series EBC

More information

Chapter. Accessories. In This Chapter...

Chapter. Accessories. In This Chapter... ccessories hapter In This hapter... ccessories Overview... - / Power dapter... - / Power dapter imensions... - / Power dapter Installation... - -SU -pin to Terminal lock dapters... - Non-glare Screen overs...

More information

Appendix D2-262 CPU. In This Appendix...

Appendix D2-262 CPU. In This Appendix... D2-262 CPU Appendix J In This Appendix... CPU Overview...J 2 CPU General Specifications...J 3 CPU Base Electrical Specifications...J 5 CPU Program/Memory Specifications Comparison...J 6 Expansion Modules

More information

Chapter. System Design and Configuration. In This Chapter:

Chapter. System Design and Configuration. In This Chapter: System esign and onfiguration hapter In This hapter: L0 System esign Strategies... Module Placement... alculating the Power udget... Local Expansion I/O... Expanding L0 I/O... Network onnections to Modbus

More information

Installation and Setup

Installation and Setup Installation and Setup 1 In This Chapter Installing the H PBC The Profibus Network Configuring the Controller Installing the H PBC Setting the Node Address Setting the Node Address Profibus DP is usually

More information

T1K MODBUS Base Controller Specifications

T1K MODBUS Base Controller Specifications Base Controller 1 2 In This Chapter.... Base Controller Setting the DIP Switches Setting the Rotary Address Switches Port Pin out and Wiring RJ12 Serial Port Pin out and Wiring 2 2 Base Controller General

More information

Installation and Setup

Installation and Setup 1 2 Setup In This Chapter.... Installing the Ethernet Base Controller EBC Network Identifiers Setting the Node Address 10BaseT / 100BaseT Network Cabling Maximum 10BaseT / 100BaseT Cable Length Specifications

More information

CHAPTER INSTALLATION AND NETWORK LAYOUTS. In This Chapter:

CHAPTER INSTALLATION AND NETWORK LAYOUTS. In This Chapter: INSTLLTION N NETWORK LYOUTS HPTER In This hapter: Inserting the ERM Module in the I/O ase............................... L0/o-more Slot hoices......................................... H ERM (00, F) Module

More information

Q-LINK SMART BYPASS. SIZING INFORMATION TABLE Q-Link Variable Frequency Drive - 3-Phase 208 VAC 230 VAC VAC HP FLA HP FLA HP FLA TECHNOLOGIES

Q-LINK SMART BYPASS. SIZING INFORMATION TABLE Q-Link Variable Frequency Drive - 3-Phase 208 VAC 230 VAC VAC HP FLA HP FLA HP FLA TECHNOLOGIES Q-LINK SMRT BYPSS 1 28, 208 480VC, 3Ø UL Type 1 Enclosure The is an integrated solution for critical applications without compromising for communications and motor protection. Unlike traditional bypasses,

More information

General Specifications. P2-08THM Analog Input

General Specifications. P2-08THM Analog Input General Specifications Operating Temperature Storage Temperature Humidity Environmental Air Vibration Shock Field to Logic Side Isolation Heat Dissipation Enclosure Type Agency Approvals Module Keying

More information

NX-series SSI Input Unit. Read position information from encoders with Synchronous Serial Interface (SSI). Features. System Configuration

NX-series SSI Input Unit. Read position information from encoders with Synchronous Serial Interface (SSI). Features. System Configuration NX-series SSI Input Unit CSM DS_E_1_1 Read position information from encoders with Synchronous Serial Interface (SSI). Process SSI encoder input data using the MC Function Modules of the NJ-series Machine

More information

General Specifications. P2-8AD4DA-2 Analog Input/Output

General Specifications. P2-8AD4DA-2 Analog Input/Output General Specifications Operating Temperature Storage Temperature Humidity Environmental Air Vibration Shock Field to Logic Side Isolation Insulation Resistance Heat Dissipation 1.95W º to 6ºC (32º to 14ºF)

More information

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections Data sheet 3379_en_B 1 Description PHOENIX CONTACT 2015-07-14 2 Features Media converters provide

More information

General Specifications. P2-08NTC Thermistor. The P2-08NTC module provides eight Thermistor input channels for use with the Productivity2000 System.

General Specifications. P2-08NTC Thermistor. The P2-08NTC module provides eight Thermistor input channels for use with the Productivity2000 System. General Specifications Operating Temperature 0º to 60ºC (32º to 140ºF) Storage Temperature -20º to 70ºC (-4º to 158ºF) Humidity 5 to 95% (non-condensing) Environmental Air No corrosive gases permitted

More information

RE17LAMW on-delay timing relay - 1 s..100 h V AC/DC - solid state output

RE17LAMW on-delay timing relay - 1 s..100 h V AC/DC - solid state output Characteristics on-delay timing relay - 1 s..100 h - 24..240 V AC/DC - solid state output Complementary Control type Voltage range Main Range of product Product or component type Discrete output type Width

More information

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600 REDUNDANCY MODULE TSP-REM360 AND TSP-REM600 Operating Instructions Seite 1 Dimensions drawings: TSP-REM360 Weight: 0.882lb Gewicht: 0.40kg Seite 2 Dimensions drawings: TSP-REM600 Bottom view Top view Side

More information

P2-04AD Analog Input. Removable Terminal Block Specifications

P2-04AD Analog Input. Removable Terminal Block Specifications WARNING: To minimize the risk of potential safety problems, you should follow all applicable local and national codes that regulate the installation and operation of your equipment. These codes vary from

More information

TRIO-DIODE/12-24DC/2X10/1X20

TRIO-DIODE/12-24DC/2X10/1X20 Redundancy module INTERFACE Data sheet 104278_en_00 1 Description PHOENIX CONTACT 20100423 Features TRIO DIODE is the DINrail mountable redundancy module from the TRIO POWER product range. Using the redundancy

More information

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output Characteristics on-delay timing relay - 1 s..100 h - 24..240 V AC/ DC - solid state output Main Range of product Product or component type Discrete output type Width Component name Time delay type Time

More information

P2-04DAL-2 Analog Output. Removable Terminal Block Specifications

P2-04DAL-2 Analog Output. Removable Terminal Block Specifications WARNING: To minimize the risk of potential safety problems, you should follow all applicable local and national codes that regulate the installation and operation of your equipment. These codes vary from

More information

RE17LCBM off-delay timing relay - control - 1 s..100 h V - solid state output

RE17LCBM off-delay timing relay - control - 1 s..100 h V - solid state output Characteristics off-delay timing relay - control - 1 s..100 h - 24..240 V - solid state output Main Range of product Product or component type Discrete output type Width Component name Time delay type

More information

RW-E. Overloads. Solid-State Overload Relays. Standard Features

RW-E. Overloads. Solid-State Overload Relays. Standard Features RW-E The new RW_E Solid State Overload relays are developed with cutting edge technology according to the most demanding standards worldwide. With its wide current/mp setting; the RW_E OL Relay can be

More information

Chapter. System design and. configuration. In This Chapter

Chapter. System design and. configuration. In This Chapter hapter System design and configuration In This hapter L0 System esign Strategies... Module Placement... Power udgeting... onfiguring the L0 s omm Ports... onnecting to MOUS and irectnet Networks... Non

More information

FL MC 2000E (SM40) LC

FL MC 2000E (SM40) LC IEC 61850 fiber optic converter with LC fiber optic connection (1310 nm) to convert 100Base-Tx to single- or multi-mode fiber glass Data sheet 3205_en_C 1 Description PHOENIX CONTACT 2014-04-04 2 Features

More information

Electronic Motor Protection Relays Bulletin 193-E

Electronic Motor Protection Relays Bulletin 193-E Electronic otor Protection Relays Bulletin 93-E 93-EB also includes: Trip Class 0, or 0 selectable Ground Fault Protection Jam/Stall Protection Product Selection... -3 ccessories dd-on ccessories... -

More information

INSTRUCTION SHEET. Eaton Logic Controller ELCB Controllers

INSTRUCTION SHEET. Eaton Logic Controller ELCB Controllers 2010-12-10 5011699201-PBB1 Eaton Logic Controller ELCB Controllers INSTRUCTION SHEET [Applicable Controllers] ELCB-PB10 ELCB-PB14 ELCB-PB20 ELCB-PB30 ELCB-PB40 IL05001005E 002-1310020-02 Thank you for

More information

P2-04DA Analog Output. Removable Terminal Block Specifications

P2-04DA Analog Output. Removable Terminal Block Specifications WARNING: To minimize the risk of potential safety problems, you should follow all applicable local and national codes that regulate the installation and operation of your equipment. These codes vary from

More information

Communication & Networking

Communication & Networking MicroSmart Master Module Capable of Connecting 62 Slaves Compliance with Ver. 2.1 specifi cations Digital and analog slaves can be connected. Configuration and slave monitoring can be done using LED indicators

More information

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

Rhino Redundancy Module PSM24-REM360S. Operating Instructions Rhino Redundancy Module PSM4-REM360S Operating Instructions RHINO REDUNDANCY MODULE PSM4-REM360S Description With this module and two power supplies of the PSM series (78, 90, 56, 80 and 360 watt models),

More information

Technical data. Housing Polyamide housing PA 66, self-extinguishing V0 acc. to UL 94. Supply Rated supply voltage (U n

Technical data. Housing Polyamide housing PA 66, self-extinguishing V0 acc. to UL 94. Supply Rated supply voltage (U n Safety module CS AT 0 Module for emergency stops, end position monitoring for movable guards with delayed contacts at the opening of the input channels, semiconductor outputs (e.g. light barriers and magnetic

More information

- 1 - Product catalogue PCB connection systems PCB terminals Clamping yoke connection LM 5.00 / 5.08 LM 5.00/135

- 1 - Product catalogue PCB connection systems PCB terminals Clamping yoke connection LM 5.00 / 5.08 LM 5.00/135 General ordering data Order No. 1715360000 Part designation LM5.00/3/135 OR Version EAN 4008190365240 Qty. 500 pc(s). PCB terminal, Clamping yoke connection, Soldered connection, Clamping range, max.:

More information

P3-SCM. General Specifications

P3-SCM. General Specifications General Specifications Module Type Modules per Base Modules per Group I/O Points Used Field Wiring Connector Operating Temperature Storage Temperature Humidity Environmental Air Vibration Shock Field to

More information

Motor protection circuit breakers

Motor protection circuit breakers R Motor protection circuit breakers Motor protection circuit breakers are used for start-up and protection of electric motors (industry, small machines, external use, agricultural machines, compressors,

More information

DIAS Interface Module VARAN DIV 511

DIAS Interface Module VARAN DIV 511 DIAS INTERFACE MODULE VARAN DIV 511 DIAS Interface Module VARAN DIV 511 1 x VARAN-In 1 x VARAN-Out (Optional Ethernet (VtE)) The DIAS DIV 511 interface module serves as the voltage supply and connection

More information

TCNM-ACBB1 Installation Manual

TCNM-ACBB1 Installation Manual The TCNM-ACBB1 is a connection box that can be used as an accessory to facilitate system connections for installation and device replacement of several Banner family reading devices. System cabling is

More information

MINI-PS AC/10-15DC/8

MINI-PS AC/10-15DC/8 Primary-Switched Power Supply, Narrow Design Data Sheet 08/2004 MINI POWER provides: An extra narrow design, with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a

More information

ECF40 Series. 40 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details

ECF40 Series. 40 Watts.   AC-DC Power Supplies. Models & Ratings. Mechanical Details 40 Watts 40 W Convection Rating 1.5 by 3 Footprint Low 1.1 Profile High Efficiency Medical and ITE pprovals High Power Density Less than 0.15 W No Load Input Power 3 Year Warranty The ECF40 series is designed

More information

VEO. V2UF230V10 Art.Nr.: TECHNICAL DATA

VEO. V2UF230V10 Art.Nr.: TECHNICAL DATA Continous voltage monitoring Mains fluctuation detection Detects voltage drop / short interruptions of at least 10ms Prevents undefined states in switching and control systems Generates reset pulse after

More information

D2 RMSM/ T1K RSSS Remote I/O System

D2 RMSM/ T1K RSSS Remote I/O System D2 RMSM/ 2 2 D2 RMSM/ Remote Master (D2-RMSM) Features RUN--Turns N when the module is operating correctly. Remote Master DIAG--Turns N when there is a hardware failure. I/--Turns N when the setup program

More information

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA Monitoring of phase sequence and phase loss Monitoring of asymmetry Supply voltage 208-480 V AC Supply circuit = measuring circuit 1 change-over contact Width 22,5 mm Control elements Asymmetry Status

More information

34 SERIES. Slim electromechanical PCB relays 6 A Ultra-slim 1 Pole - 6 A relay

34 SERIES. Slim electromechanical PCB relays 6 A Ultra-slim 1 Pole - 6 A relay 34 Slim electromechanical PCB relays 6 34 Ultra-slim 1 Pole - 6 relay Printed circuit mount - direct or via PCB socket 35 mm rail mount - via screw, screwless or push-in terminal sockets 34.51 34.51-5010

More information

Chapter. Accessories. In this Chapter...

Chapter. Accessories. In this Chapter... ccessories hapter In this hapter... ccessories...- -more Micro Programming Software...- E-EOM Ethernet ommunication Module...- -SU -pin 0-degree ommunication Port dapter...- -SU -pin to Terminal lock dapters...-

More information

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m Characteristics I/O distributed module OTB - Ethernet TCP/IP - 0..100 m Main Range of product Product or component type Integrated connection type Mar 31, 2018 Modicon OTB I/O distributed module Discrete

More information

Common to all H3DS. Installation of Screw-Less Clamp Models. Tools. Applicable Wires. Applicable Screwdriver. Applicable Wire Sizes

Common to all H3DS. Installation of Screw-Less Clamp Models. Tools. Applicable Wires. Applicable Screwdriver. Applicable Wire Sizes Common to all H3DS Installation of Screw-Less Clamp Models Tools A flat-blade screwdriver should be used to mount the cables. Timers Applicable Screwdriver Flat-blade, Parallel-tip, 2.5 mm diameter Flat-blade,

More information

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Rhino Buffer Module PSM24-BFM600S. Operating Instructions Rhino Buffer Module PSM24-BFM600S Operating Instructions RHINO BUFFER MODULE PSM24-BFM600S Description The PSM24-BFM600S Buffer Module will hold the output voltage of a 24 VDC power supply after brownouts

More information

Conforms to VDE0435/2021 C/250, VDE0110, VDE0106/P100 Conforms to EN , pren

Conforms to VDE0435/2021 C/250, VDE0110, VDE0106/P100 Conforms to EN , pren Solid-state Power OFF-delay Timer II DIN 22.5-mm Solid-state Power OFF-delay Timer High immunity to invertor noise. Long power OFF-delay times; S-series: up to 12 seconds, L-series: up to 120 seconds.

More information

Classification Enclosure rating Input voltage Type of

Classification Enclosure rating Input voltage Type of Slim Relay G2RV The World's First Industrial Slim Relay Large plug-in terminals for reliable connection. LED indicator and mechanical flag to check operation. Special input type with gold plated contacts.

More information

Installation Instructions

Installation Instructions Installation Instructions (Cat. No. 1794-PS1) 1 2 3 4 5 7 6 Component Identification 1 Supply module 1794-PS1 2 Indicator 3 120/230V ac ground 4 120/230V ac common L2/N connections 5 120/230V ac power

More information

Sockets and accessories for auxiliary relays

Sockets and accessories for auxiliary relays ÍNDEX Sockets and accessories for auxiliary relays User manual Sockets and accessories for auxiliary relays User manual 1 651.601.437 Rev: 8 Date: 09/08/2016 ARTECHE Power Grid, S.L. This document, including

More information

Tempco Instruction Manual

Tempco Instruction Manual Tempco Instruction Manual 1/16 DIN Solid State Temperature Controller Relay Output Solid State Output For Heating Model Numbers: TEC-901, TEC-902, TEC-905 Temperature controls in this series are designed

More information

GT3F Series True OFF Delay Timers

GT3F Series True OFF Delay Timers TF Series TF Series True OFF Delay Key features of the TF series include: Mountable in sockets or flush panel True power OFF-delay up to 10 minutes No external control switch necessary Available with reset

More information

Slim Relay G2RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. Relay and Socket Combinations

Slim Relay G2RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. Relay and Socket Combinations Slim Relay G2RV The World's First Industrial Slim Relay Large plug-in terminals for reliable connection. LED indicator and mechanical flag to check operation. Transparent housing enables checking relay

More information

Appendix G. CJ1W-CIF11 RS-422A Converter

Appendix G. CJ1W-CIF11 RS-422A Converter CJ1W-CIF11 RS-422A Converter The CJ1W-CIF11 RS-422A Converter connects directly to a CS/CJ-series RS-232C port and converts RS- 232C to RS-422A/485. Specifications General Specifications Item Specification

More information

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m Characteristics I/O distributed module OTB - Ethernet TCP/IP - 0..100 m Complementary Concept Port Ethernet Bus length Main Number of devices per segment 0...256 Communication service Web services Discrete

More information

40 Series - Miniature PCB/Plug-in relays A. 3.5 mm contact pin pitch 1 Pole 10 A PCB or 95 series sockets.

40 Series - Miniature PCB/Plug-in relays A. 3.5 mm contact pin pitch 1 Pole 10 A PCB or 95 series sockets. 40 Series - Miniature PCB/Plug-in relays 8-10 - 12-16 40 1 & 2 Pole relay range 40.31-1 Pole 10 (3.5 mm pin pitch) 40.51-1 Pole 10 (5 mm pin pitch) 40.52-2 Pole 8 (5 mm pin pitch) PCB mount - direct or

More information

TSP-BCM48, TSP-BCM48A. Operating Instruction Manual. Page 1 of 13

TSP-BCM48, TSP-BCM48A. Operating Instruction Manual.  Page 1 of 13 Battery Controller Module TSP-BCM24, TSP-BCM24A TSP-BCM48, TSP-BCM48A Operating Instruction Manual http://www.tracopower.com Page 1 of 13 Dimensions drawings: TSP-BCM24 & TSP-BCM48 Weight: 0.816lb Gewicht:

More information

Miniature PCB Relays A

Miniature PCB Relays A SЕRIES Miniature PCB Relays 8-10 - 12-16 Medical and dentistry Control panels Panels for electrical distribution Toys utomation for blinds, grilles and shutters Door and gate openers Electronic circuit

More information

1492-SP Supplementary Protectors

1492-SP Supplementary Protectors Dual terminals provide wiring/bus bar flexibility and clamp from both sides to improve connection reliability Approval marks are easily visible on dome Terminal design helps prevent wiring misses Scratch-

More information

Control elements. Fine adjustment. Status indication. 24 V DC typ. 0,25 W / 0,25 VA. 24 V DC typ. 0,03 W / 0,09 VA. 0,15 3 s. 0,5 10 h.

Control elements. Fine adjustment. Status indication. 24 V DC typ. 0,25 W / 0,25 VA. 24 V DC typ. 0,03 W / 0,09 VA. 0,15 3 s. 0,5 10 h. On-Delay 10 time ranges Supply voltage 24-240V AC/DC 1 change-over contact Width 22,5mm Control elements Fine adjustment Setting of time range Status indication LED U/t: Supply voltage LED R: Relay status

More information

PHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

PHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area. Primary switched power supply, 3-phase, output current: 40 A INTERFACE Data Sheet 102782_01_en PHOENIX CONTACT - 06/2007 Description TRIO POWER is the rail mountable 24 V power supply unit with basic functions.

More information

Main Unit AC or DC power

Main Unit AC or DC power Main Unit AC or DC power General Specification /DC /DC XEC-DR32H XEC-DN32H Ambient temperature Storage temperature Ambient humidity Storage humidity Vibration resistance Shock resistance Noise resistance

More information

NJ-Series Power Supply Unit NJ-PA/PD

NJ-Series Power Supply Unit NJ-PA/PD NJ-Series Power Supply Unit CSM_NJ-PA_PD_DS_E_1_2 Powerful power supply unit to supply stable power to the NJ-series controller. Stable power supply is available from the NJ-series CPU Unit to each I/O

More information

Safety Control. FS1A Multi-function Safety Relay. Optional Parts. Connecting Tool. Marked Cable Tie. DIN Rail BNDN1000 Aluminum, 1m 35mm wide

Safety Control. FS1A Multi-function Safety Relay. Optional Parts. Connecting Tool. Marked Cable Tie. DIN Rail BNDN1000 Aluminum, 1m 35mm wide Multi-function Relay Key features: No programming required. Configuration complete by turning on a logic switch A safety circuit can be configured easily just by selecting a logic from eight preprogrammed

More information

CHAPTER ACCESSORIES. In This Chapter...

CHAPTER ACCESSORIES. In This Chapter... ESSORIES HPTER In This hapter... ccessories........................................................ -more Micro-Graphic Programming Software............................ US to RS- Programming able ssembly.............................

More information

OTB1C0DM9LP I/O distributed module OTB - CANopen bus m

OTB1C0DM9LP I/O distributed module OTB - CANopen bus m Characteristics I/O distributed module OTB - CANopen bus - 0..1000 m Main Range of product Product or component type Integrated connection type Bus type Jan 28, 2018 Modicon OTB I/O distributed module

More information

Installation Instructions

Installation Instructions Installation Instructions (Cat. No. 1794-TBN) 6 1 5 9 4 2 3 10 6 7 8 Component Identification 1 Female flexbus connector 2 Terminal base unit (1794-TBN) 3 Male flexbus connector 4 Keyswitch Set to the

More information

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m Characteristics I/O distributed module OTB - Modbus non isolated serial link - 0..10 m Complementary Topology Bus length Main Number of devices per segment 0...32 Data format Parity Discrete input voltage

More information

Safety Control. FS1A Multi-function Safety Relay. Optional Parts. Marked Cable Tie. DIN Rail BNDN1000 Aluminum, 1m 35mm wide

Safety Control. FS1A Multi-function Safety Relay. Optional Parts. Marked Cable Tie. DIN Rail BNDN1000 Aluminum, 1m 35mm wide Control Multi-function Relay Key features: No programming required. Configuration complete by turning on a logic switch A safety circuit can be configured easily just by selecting a logic from eight preprogrammed

More information

ETD-BL-1T-OFF-CC- 10S

ETD-BL-1T-OFF-CC- 10S Timer relay with off delay (with control contact) and adjustable time Data sheet 103617_en_03 1 Description PHOENIX CONTACT - 2013-09-16 Features Compact timer relay in 6.2 mm housing for controlling time

More information

VEO. V2ZS V AC/DC Art.Nr.: V2ZS20P V AC/DC Art.Nr.: TECHNICAL DATA

VEO. V2ZS V AC/DC Art.Nr.: V2ZS20P V AC/DC Art.Nr.: TECHNICAL DATA 4 time ranges 4 transition times Supply voltage 12-240V AC/DC 2 normally open contacts Width 22,5 mm Control elements Fine adjustment star contactor Setting of time range star contactor Transit time Status

More information

TM3SAC5RG SAFETY MODULE FOR PLC TM2xx, 1 FUNCTION, CAT3, SPRING TERMINALS

TM3SAC5RG SAFETY MODULE FOR PLC TM2xx, 1 FUNCTION, CAT3, SPRING TERMINALS Characteristics SAFETY MODULE FOR PLC TM2xx, 1 FUNCTION, CAT3, SPRING TERMINALS Main Range of product Product or component type Device short name Safety module application Function of module Jun 29, 2018

More information

Chapter. In This Chapter:

Chapter. In This Chapter: hapter Installation, Wiring and Specifications In This hapter: Safety Guidelines... Mounting Guidelines... Installing ases... Installing omponents in the ase... ase Wiring Guidelines... I/O Wiring Strategies...

More information

TM3SAF. Main. Device short name

TM3SAF. Main. Device short name Product datasheet Characteristics TM3SAF5R SAFETY MODULE FOR PLC TM2xx, 1 FUNCTION, CAT4, SCREW TERMINALS Complementary Main Range of product Product or component type Device short name Safety module application

More information

Solid-state Timers H3DK

Solid-state Timers H3DK New Product News Solid-state Timers H3DK DIN Track-mounted, 22.5-mm-width Standard Timer Series LR A wide AC/DC power supply range (24 to 240 VAC/DC).*1 All sub-series include models with 12-VDC power

More information

GSP750 Series. 750 Watts. AC-DC Power Supplies. Models & Ratings. Input

GSP750 Series. 750 Watts.   AC-DC Power Supplies. Models & Ratings. Input C-DC Power Supplies 750 Watts 900 W Peak Power Rating for 100 ms Universal 80-264 VC Input IT & Medical Safety pprovals 1.0 W Standby Power -40 C to +70 C Operation Remote On/Off 5 V/3 Standby Output 3

More information

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m Product datasheet Characteristics OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP - 0..100 m Complementary Concept Port Ethernet Bus length Main Number of devices per segment 0...256 Communication

More information

OTB1C0DM9LP I/O distributed module OTB - CANopen bus m

OTB1C0DM9LP I/O distributed module OTB - CANopen bus m Characteristics I/O distributed module OTB - CANopen bus - 0..1000 m Complementary Topology Main Range of product Product or component type Integrated connection type Bus type Number of slave 0...63 Bus

More information

Output Voltage* (nom.)(adjustable)

Output Voltage* (nom.)(adjustable) Industrial Power Supplies TBLC Series, 6 90 W Low profile case, module depth only 59,5mm Suitable for mounting in domestic installation panels Low output ripples and spikes Fully compliance to ECO-Standard

More information

Hardened 10/100Base-TX IEEE802.3at PoE PSE Ethernet Extender

Hardened 10/100Base-TX IEEE802.3at PoE PSE Ethernet Extender Quick Start Guide This quick start guide describes how to install and use the Hardened Ethernet Extender. This is the Hardened Ethernet Extender of choice for harsh environments constrained by space. Physical

More information

OTB1C0DM9LP. Main , length of segment <= 185 m , length of segment <= 160 m. 3.4 kohm for I8...I kohm I0...I1 5.7 kohm I6...

OTB1C0DM9LP. Main , length of segment <= 185 m , length of segment <= 160 m. 3.4 kohm for I8...I kohm I0...I1 5.7 kohm I6... Product datasheet Characteristics OTB1C0DM9LP Complementary Topology Number of slave 63 Bus length Number of devices per segment Discrete input voltage Discrete input voltage type Discrete input type Input

More information

Power supply CP-C 24/5.0

Power supply CP-C 24/5.0 2CDC 271 064 F0004 Features Supply voltage ranges: 85-264 V AC, 100-350 V DC Output voltage adjustable from 22-28 V DC, default setting 24 V DC 0,5 % 5 A output current Open-circuit, overload and continous

More information

Electrical Components Catalog Universal MATE-N-LOK Connector System

Electrical Components Catalog Universal MATE-N-LOK Connector System Introduction Product Facts Pins and sockets can be intermixed in the same housing Positive polarization Rear cavity identification Contacts completely enclosed in housings Positive locking housings Insulation

More information

RTU500 series Data Sheet Power Supply CP-E 24/2.5

RTU500 series Data Sheet Power Supply CP-E 24/2.5 Data Sheet Power Supply CP-E 24/2.5 Power Supply CP-E 24/2.5 Application The primary switch mode power supply offers two voltage input ranges. This enables the supply with AC or DC. Furthermore it is equipped

More information

GE Industrial Solutions. DET-756 Installation Instructions ASPMETER Panelboard Monitoring System

GE Industrial Solutions. DET-756 Installation Instructions ASPMETER Panelboard Monitoring System GE Industrial Solutions DET-756 Installation Instructions SPMETER Panelboard Monitoring System Safety If SPMETER products are used in installations with circuits higher than the product ratings, the circuits

More information

PanelView Plus/VersaView CE Terminals and Display Modules

PanelView Plus/VersaView CE Terminals and Display Modules Installation Instructions PanelView Plus/VersaView CE Terminals and Display Modules (Catalog Numbers 2711P-xxxxxx, 6182H-xxxxxx) English Inside: Overview...2 For More Information...2 Modular Components...3

More information

USER S MANUAL Power Supply for Backplane Vdc

USER S MANUAL Power Supply for Backplane Vdc USER S MANUAL Power Supply for Backplane 20-30 Vdc D F 5 6 M E smar www.smar.com Specifications and information are subject to change without notice. Up-to-date address information is available on our

More information

Safety Relay Unit (I/O Unit Type)

Safety Relay Unit (I/O Unit Type) Safety Relay Unit (I/O Unit Type) CQM1-SF200/ CS1W-SF200 Same Dimensions as I/O Unit Less Installation Space and Wiring Required Safety Relay Unit that can be used as an I/O Unit for OMRON s CQM1H and

More information

CI-TI Contactors and Motor Starters Circuit Breakers CTI 25M, CTI 45MB, CTI 100

CI-TI Contactors and Motor Starters Circuit Breakers CTI 25M, CTI 45MB, CTI 100 MKING MODERN LIVING POSSIBLE Technical brochure CI-TI Contactors and Motor Starters Circuit Breakers CTI 25M, CTI 45MB, CTI 100 Circuit breakers for short circuit- and overload protection of motor applications

More information

TRIO-PS/1AC/24DC/20. Extract from the online catalog. Order No.:

TRIO-PS/1AC/24DC/20. Extract from the online catalog. Order No.: Extract from the online catalog TRIO-PS/1AC/24DC/20 Order No.: 2866381 DIN rail power supply unit, primary-switched mode, 1-phase, output: 24 V DC / 20 A Commercial data EAN 4046356046664 Pack 1 pcs. Customs

More information

Modbus Digital Remote I/O. ARM Series. Modbus Sensor Connector Type Digital Remote I/O. Features. User Manual For Communication. Ordering Information

Modbus Digital Remote I/O. ARM Series. Modbus Sensor Connector Type Digital Remote I/O. Features. User Manual For Communication. Ordering Information RM Series Modbus Digital Remote I/O Modbus Connector Type Digital Remote I/O Features Modbus RTU standard protocol Connects with sensor connector, e-con: saves wiring work (sensor connector, CNE Series,

More information

Output Voltage* (nom.)(adjustable)

Output Voltage* (nom.)(adjustable) Industrial Power Supplies TBLC Series, 6 90 W Low profile case, module depth only 55 mm Suitable for mounting in domestic installation panels Very high efficiency and low standby power -> compliance to

More information

4-Pole Relay. 2 Coil. [V] Hz A1 A2 60 Hz A24 A1 A20 A2

4-Pole Relay. 2 Coil. [V] Hz A1 A2 60 Hz A24 A1 A20 A2 ulletin - Product Overview/Product Selection ulletin - Industrial Relay ontact cartridges convertible from.o. to.. and vice versa EM V coils Pneumatic timing unit Solid-state timing unit Overlap contacts

More information

Network Instrumentation Module Communications box NX-CB1 Communications adapter NX-CL1/NX-CR1 Terminal adapter NX-TL1/NX-TR1

Network Instrumentation Module Communications box NX-CB1 Communications adapter NX-CL1/NX-CR1 Terminal adapter NX-TL1/NX-TR1 No. CP-SS-1865E Network Instrumentation Module Communications box NX-CB1 Communications adapter NX-CL1/NX-CR1 Terminal adapter NX-TL1/NX-TR1 Overview Network Instrumentation Modules make optimal distributed

More information

Technical data. Dimensions: see page 116. ): 4 kv Rated insulation voltage (U i Over-voltage category: Power supply. Rated operating voltage (Un):

Technical data. Dimensions: see page 116. ): 4 kv Rated insulation voltage (U i Over-voltage category: Power supply. Rated operating voltage (Un): Safety module CS AR-91, according to EN 81 Safety modules for the lift automatic floor levelling operation according to EN 81 Main functions For safety applications up to SIL 3 / PL e Choice between automatic

More information