BACS_GX_R_AUX Businterface

Size: px
Start display at page:

Download "BACS_GX_R_AUX Businterface"

Transcription

1 Version: BACS_GX_R_AUX Businterface Attention!: If you connect GX_R_AUX to your system, please make sure that your BACS BUS CONVERTER or BACS WEBMANAGER BUDGET II/III will be supply via regulated/stabilized 12VDC power supply. The supply voltage has to be stabilized (+/- 0,5 VDC) otherwise a fuse inside the GX_R_AUX will open. Description & Function: The GX_R_AUX is a additional device for the integration into the BACS II bus system of the BACSWEBMANAGER Budget or BACSWEBMANAGER Budget II/III. It is possible to connect up to 4 GX_R_AUX devices in one BACS system. Each GX_R_AUX has 4 inputs and 4 outputs. With these ones it is possible to monitor dry contacts (motion detector, fire detector, relay contact, etc.) or do switching operation via dry two-way contacts. Configuration of the inputs and outputs: The configuration (description and logic) of the inputs and outputs is available on the http webinterface COM2 & AUX. Also the number of connected GX_R_AUX will configure here: The inputs of the GX_R_AUX are available in the Events / Alarms configuration, where defined jobs are configurable for them (e.g. alarmlog, , RCCMD, etc.): The outputs can be switch manually via button on the http webinterface AUX Status, but also via configurable jobs in the Events / Alarms configuration:

2 Status of the inputs and outputs: The status of the inputs and outputs is visible on the http webinterface AUX Status. Also the status is shown via LED s on the GX_R_AUX itself. Status inputs: Status outputs: Configuration BACS Thermal Runaway: Additionally to the manual configuration of the GX_R_AUX outputs, it is possible to configure conditions for a upcoming Thermal Runaway. Through a connection with a battery breaker, this device can isolate batteries from the UPS according to the US Norm International Fire Code IFC requirements. With this configuration it is possible to activate battery breakers via the GX_R_AUX outputs, to avoid the Thermal Runaway. The configuration of the Thermal Runaway conditions are available on the http webinterface BACS Configuration : Max. difference modul temperature : Type in the difference to the average battery temperature in degree celsius or fahrenheit to define the upcoming Thermal Runaway. Optionally: max. current per string : Type in the charging current in A (ampere), which defined together with the max. Difference modul temperatur the upcoming Thermal Runaway. The entry 0 disable this condition. Optionally: active time of the conditions above : Type in the time period after the upcoming Thermal Runaway will be activate, if the condition ( Max. difference modul temperature or Max. difference modul temperature and max. current per string ) is true above this time period. The entry 0 disable this condition. Battery breaker (number of connected GX_R_AUX ) : Type in the number of connected GX_R_AUX to the BACS bus (max.4 pcs.).

3 Do not trip battery breakers active : The GX_R_AUX outputs will not be activate via Thermal Runaway conditions. Trip a single Battery-Breaker for all strings active: If the condition for the upcoming Thermal Runaway is true, only 1 output of the GX_R_AUX will switch. This outlet should activate the common battery breaker for all strings: Trip separate Battery-Breakers for each string active: Only the GX_R_AUX outlet will be switched, which are dedicated to the string where the condition for an upcoming Thermal Runaway is true (below the max. facility): Assembling: The GX_R_AUX is designed for DIN Rail mounting.

4 Bus Connection: The GX_R_AUX devices will be connected via a separate bus communication cable to the BACS BUSCONVERTER / SPLITTINGBOX / BACSWEBMANGER_BII/III. Do not use the GX_R_AUX on a bus communictioan cable which is also connected to BACS modules. The BUS1 RJ10 port of the GX_R_AUX device has to be connected to the battery bus port of the BACS CONVERTER/SPLITTING BOX/BACSWEBMANAGER_BII/II via buscable. Please reserve one of the two battery bus ports of the BACS BUSCONVERTER / BACSWEBMANGER_BII/III or if occupied one port of the SPLITTINGBOX for the GX_R_AUX. It is possible to connect up to 4 pcs. GX_R_AUX to the bus. Use the BUS2 Rj10 port of the GX_R_AUX to connect more GX_R_AUX devices. Adressing: The GX_R_AUX will be adressed via the 4 pole dip switch ADRESS. The switch setting defined the ID of the GX_R_AUX. The table below shows the possible switch settings and ID definition: DIP1: DIP2: DIP3: DIP4: Device ID: off off off off GX_R_AUX 1 on off off off GX_R_AUX 2 off on off off GX_R_AUX 3 on on off off GX_R_AUX 4 off off on off GX_R_AUX 5 on off on off GX_R_AUX 6 off on on off GX_R_AUX 7 on on on off GX_R_AUX 8 off off off on GX_R_AUX 9 on off off on GX_R_AUX 10 If you change the switch settings during the operation mode a short disconnection of the power supply (buscable) is necessary to activate the new configured ID. Status LED: The green status LED on the GX_R_AUX is blinking if the bus power supply is connected and lit static if the bus power supply is connected and the communication to the BACSWEBMANAGER has started (normal operation). If the communication will be disconnect the LED start blinking after about 60 sec. Design BACS_ GX_R_AUX :

5 GX_R_AUX terminals description screw terminals top 1-14: 1. Not Connected 2. Not Connected 3. Digital Input V (supply for input 1) 5. Digital Input V (supply for input 2) 7. Digital Input V (supply for input 3) 9. Digital Input V (supply for input 4) 11. Alternative BACS bus +12V power supply 12. Alternative BACS bus data input 13. Alternative BACS bus data output 14. Alternative BACS bus ground Alternative BACS bus: Pins 11 to 14 don t need to be connected, when the device is powered over BUS1 or BUS2 RJ-10 jack by BACS bus. If a connection through BUS1 or BUS2 is not wanted, you may use the alternative BACS bus connectors Pin on this GX_R_AUX terminal. Description screw terminals bottom 15-28: 15. Relay 1 NO 16. Relay 1 NC 17. Relay 1 Common 18. Relay 2 NO 19. Relay 2 NC 20. Relay 2 Common 21. Relay 3 NO 22. Relay 3 NC 23. Relay 3 Common 24. Relay 4 NO 25. Relay 4 NC 26. Relay 4 Common 27. Not connected 28. Not connected NO: normally open NC: normally close

6 Technical data and specification BACS GX_R_AUX: description : GX_R_AUX BACS Businterface Voltage range power supply : 12 VDC (ATTENTION : only use a regulated/stabilized 12VDC power supply!) supply: via 4pol. BACS bus communictaion cable current consumption typical: about. 170mA control: DIP-switch for ID assignation indicator: LED for status, inputs and outputs connections: 2 Rj10-ports,28 screw terminals (4 dry relay contacts (two-way contacts), 4 digital inputs, BACS Bus) Busprotocol: proprietary Generex busprotocol, 9600 Baud Max. relay contact load: 30VAC 2A, 30VDC 1A Operating temperature : Temperature 0-60 C, max. Humidity 90% Humidity: 0-95% not condensated Dimensions : 75 x 75 x 47.5 mm = 2,95 x 2,95 x 1,87 in. (B x H x T) Weight: 170g Protection class : IP 20 Housing: PC (Polycarbonate) Certifications: DIN EN 50178, RoHS

Switched Mode Power Supply Operating manual PAP800

Switched Mode Power Supply Operating manual PAP800 Features: Switched mode power supply Wide output 0 144Vdc Analog control by an external 0 5Vdc Power failure alarm output Master-slave connection Powerfinn PAP series is a high power, lightweight, advanced

More information

BMCS CCX Cabinet. BMCS_CCX Cabinet is secured via a switchable 6A circuit breaker. Note the right selectivity ratio of your feeding.

BMCS CCX Cabinet. BMCS_CCX Cabinet is secured via a switchable 6A circuit breaker. Note the right selectivity ratio of your feeding. Version: 2011-01-13 BMCS CCX Cabinet Description & Function: The BMCS_CCX Cabinet is a ready to install wall housing for one or more BMCS systems (see figures 1 to 3). The BMCS_CCX Cabinet is designed

More information

DIN-RAIL EXPANDER int-iors_en 10/14

DIN-RAIL EXPANDER int-iors_en 10/14 INT-IORS INT-ORS DIN-RAIL EXPANDER int-iors_en 10/14 The INT-IORS expander enables the system to be expanded by 8 programmable wired zones and 8 programmable wired outputs. The INT-ORS expander enables

More information

IEC-4001/4002/4301. Quick Installation Guide. Industrial mini Media Converter 10/100Base-TX to 100Base-FX. v

IEC-4001/4002/4301. Quick Installation Guide. Industrial mini Media Converter 10/100Base-TX to 100Base-FX. v IEC-4001/4002/4301 Industrial mini Media Converter 10/100Base-TX to 100Base-FX Quick Installation Guide v1.00-1402 Overview LevelOne IEC-4001/4002/4301 is an industrial Fast Ethernet media converter with

More information

iologik E4200 Modular Active Ethernet I/O adaptor IT and Instrumentation for industry Introduction Specifications LAN Regulatory Approvals Warranty

iologik E4200 Modular Active Ethernet I/O adaptor IT and Instrumentation for industry Introduction Specifications LAN Regulatory Approvals Warranty ioogik E4200 Modular Active Ethernet I/O adaptor Supports up to 16 I/O modules Dual Ethernet ANs and one RS-232 port Front-end intelligence that supports 80 Click&Go rules Unicode Active Messaging with

More information

Expansion Module HZS 541-1S

Expansion Module HZS 541-1S Expansion Module HZS 541-1S 12.10.2015 Page 1 System Description The external HZS 541-1S expansion module provides users of biomass heating systems with additional 230 V AC relay outputs, analog inputs

More information

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D D600S - D600D INSTRUCTI MANUAL SIL Switch/Proximity Detector Repeater Relay, DIN Rail, Models D600S, D600D D600 - SIL Switch/Proximity Detector Repeater Relay G.M. International ISM0- Characteristics General

More information

SDM-6RO. Expansion Module 6 relay outputs. Manufactured for

SDM-6RO. Expansion Module 6 relay outputs. Manufactured for Version 1.0 5.02.2014 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have

More information

Industrial PoE Media Converter

Industrial PoE Media Converter Quick Start Guide This quick start guide describes how to install and use the Industrial PoE Media Converter. This is the Media Converter of choice for harsh environments constrained by space. Physical

More information

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors B Curve NC100H Supplementary Protectors Rating 1P 2P 3P 4P 80 MG27164 MG27175 MG27186 MG27197 MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors C Curve NC100H Supplementary Protectors

More information

Hardened PoE Ethernet Switch

Hardened PoE Ethernet Switch Quick Start Guide This quick start guide describes how to install and use the Hardened PoE Ethernet Switch. This is the switch of choice for harsh environments constrained by space. Physical Description

More information

iologik 4000 Series (M) Modules

iologik 4000 Series (M) Modules iologik 4000 Series (M) s Remote I/O modules Features and Benefits I/O expansion without a backplane Active communication with MX-AOPC UA Server Supports SNMP v1/v2c Easy configuration with Modular ioadmin

More information

9926 Series Branch Rated Circuit Breakers AC Version

9926 Series Branch Rated Circuit Breakers AC Version Branch Rated AC Version Hydraulic Magnetic Single pole and double pole versions 20/240 VAC, 50/60 Hz Up to 25A Just 3 mm wide Mounts on 35mm DIN-rail UL 489 listed, CSA C22.2 No. 5-02, CE VDE Ordering

More information

XT-9100 Technical Bulletin

XT-9100 Technical Bulletin System 9100 Technical Manual 636.4 Technical Bulletins Section Technical Bulletin Issue Date 0896 XT-9100 Technical Bulletin XT-9100 Extension Module/XP-910x Expansion Modules Page 3 Introduction 3 SX

More information

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies ADC7520 SERIES 1600W Battery Chargers and Power Supplies Wide output adjustment range 0 72VDC Analog control by external 0-5VDC voltage Temp.comp charging, sense as on option Power fail relay alarm Master-Slave

More information

IES User Manual. 8 FE + 1 MM SC Unmanaged Switch -40 to 75, DIN-rail. v

IES User Manual. 8 FE + 1 MM SC Unmanaged Switch -40 to 75, DIN-rail. v IES-0920 8 FE + 1 MM SC Unmanaged Switch -40 to 75, DIN-rail User Manual v1.00-1206 Preface This manual describes how to install and use the Industrial Ethernet Switch. This switch integrates full wire

More information

Remote I/O Product Specification

Remote I/O Product Specification Table of Contents 1. Product Overview... 1 1.1 Product List:... 1 1.1.1 Coupler List:... 1 1.1.2 Digital I/O List:... 1 2. Fieldbus Coupler... 2 2.1 CANopen Specifications... 2 2.2 Ethernet TCP/IP Specifications...

More information

Compact Coded Magnetic Safety Interlock Switch and Control Units

Compact Coded Magnetic Safety Interlock Switch and Control Units C Conforms to EN292, EN60204-1, EN954-1, EN1088, EN60947-5-3, EN947-5-3, EN50081, EN50082, EN61000-6-2 UL and C-UL listed, TUV certified Description R US Compact Coded Magnetic Safety Interlock Switch

More information

Operating Instructions. For. Level Control Module. Model SSR 1000

Operating Instructions. For. Level Control Module. Model SSR 1000 Operating Instructions For Level Control Module Model SSR 1000 SSR Operation Instructions Rev. 1 Jan 01 Page 1/7 1. Note Please read and take note of these operating instructions before unpacking and commissioning.

More information

MICROFUSION FEATURES OPTIONS CERTIFICATIONS (PENDING) THREE PHASE SCR POWER CONTROLLERS

MICROFUSION FEATURES OPTIONS CERTIFICATIONS (PENDING) THREE PHASE SCR POWER CONTROLLERS MICROFUSION THREE PHASE SCR POWER CONTROLLERS FEATURES Auto-Ranging Input Voltage 24-600 VAC, 45-65 Hz AC Output 16, 32, 50, 80 Amps (@ 50 C 6000 ft) Control Features Microprocessor-based controller /

More information

ABL8BBU24400 battery control module V DC - 24 V - 40 A - for regulated SMPS

ABL8BBU24400 battery control module V DC - 24 V - 40 A - for regulated SMPS Characteristics battery control module - 24..28.8 V DC - 24 V - 40 A - for regulated SMPS Main Range of product Product or component type Input voltage Output voltage Maximum output current Complementary

More information

Remote I/O Product Specification

Remote I/O Product Specification Table of Contents 1. Product Overview... 1 1.1 Product List:... 1 1.1.1 Coupler List:... 1 1.1.2 Digital I/O List:... 1 2. Fieldbus Coupler... 2 2.1 CANopen Specifications... 2 2.2 Ethernet TCP/IP Specifications...

More information

Module Technical characteristics

Module Technical characteristics Module Technical characteristics Power supply 220VAC Average power consomption 0.1W Peak power consumption 25W Battery 1400mAh :(charge average about 3 days ) 4 Input opto-isolated 220AC o 12VDC 4 separated

More information

IntesisBox Modbus Server - Honeywell XLS 80

IntesisBox Modbus Server - Honeywell XLS 80 IntesisBox Server - Honeywell XLS 80 Gateway for integration of Honeywell XLS 80 fire panels into (RTU and TCP) enabled control systems. Integrate your Honeywell fire panels into your master device or

More information

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers Analog Data Links Multi-Channel Contact Closures Multiplexers Digital Data Links - Contact Closures Power Supply

More information

PTC-101-M12 Hardware Installation Guide

PTC-101-M12 Hardware Installation Guide PTC-101-M12 Hardware Installation Guide Moxa Industrial Media Converter Third Edition, May 2014 2014 Moxa Inc. All rights reserved. P/N: 1802001016021 Overview The PTC-101-M12 industrial media converter

More information

Modbus Server SIEMENS Algorex (printer port)

Modbus Server SIEMENS Algorex (printer port) IntesisBox Server SIEMENS (printer port) Gateway for the integration of Siemens fire detection panels into enabled control systems. Monitor your fire panels remoy from your Control Center using any commercial

More information

MSR Level Control Relay Module Operating Instructions for Level Control Relay Module Model: MSR

MSR Level Control Relay Module Operating Instructions for Level Control Relay Module Model: MSR Operating Instructions for Level Control Relay Module Model: MSR MSR Operation Instructions Rev. Apr 07 Page 1/8 1. Note Please read and take note of these operating instructions before unpacking and commissioning.

More information

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3 INSTALLATION MANUAL LC 200 Electronic Overload Guard Software versione PW0501 R 0.3 CONTENTS MAIN FEATURES LC 200 TECHNICAL FEATURES Page 2 SYMBOLS Page 3 WARNINGS Page 3 IDENTIFICATION DATA PLATE Page

More information

Bus Connection Unit 560BCU04

Bus Connection Unit 560BCU04 Bus Connection Unit 560BCU04 Application The Bus Connection Unit 560BCU04 R0001 is designed to make the RTU560s TSI, TSO, Alarm and Warning signals accessible to the outside. By using the bus connection

More information

Buffered Power Supply PS-30DR v1.0

Buffered Power Supply PS-30DR v1.0 Roger Access Control System Buffered Power Supply PS-30DR v1.0 Document version: Rev. C Firmware: 1.0.4 1. PRODUCT DESCRIPTION The PS-30DR is dedicated for electronic equipment which require 12VDC buffered

More information

I/O Expansion Module Installation & Reference

I/O Expansion Module Installation & Reference Overview The In-Sight vision sensor supports up to ten discrete inputs and ten discrete outputs. Two inputs and two outputs are built-in to the In-Sight processor. The remaining eight inputs and outputs

More information

MSR 2400W. Multi purpose Power System for Telecom and Industrial Applications. Nominal Output Voltage. Voltage Setting Range

MSR 2400W. Multi purpose Power System for Telecom and Industrial Applications. Nominal Output Voltage. Voltage Setting Range MSR 2400W Multi purpose Power System for Telecom and Industrial Applications 2400 W modular system All voltages available 0 144VDC per module U and I adjustable from 0 to max value Hot-swap plug-in modules

More information

Process displays For current and voltage

Process displays For current and voltage Features Voltage input TRMS-AC/DC up to 600 V Current input AC/DC 1 A, 5 A and shunt (precision resistor) 60 or 100 mv With 2 or 4 limits Display range can be linearised Min, Max, Hold functions 4 20 ma

More information

Technical Manual Nova: Cabinet Security Management System (CSMS)

Technical Manual Nova: Cabinet Security Management System (CSMS) Technical Manual Nova: Cabinet Security Management System (CSMS) KP_nova_TM_160501_EN 1 Publication May, 2016, Keyprocessor BV Paasheuvelweg 20 1105BJ Amsterdam, The Netherlands www.keyprocessor.com/nova

More information

8-Port IP40 IEEE802.3af PoE Unmanaged Industrial Switch User s Manual

8-Port IP40 IEEE802.3af PoE Unmanaged Industrial Switch User s Manual 8-Port IP40 IEEE802.3af PoE Unmanaged Industrial Switch User s Manual Version 1.1 Content Overview... 1 Introduction... 1 Features... 2 Technical Specifications... 3 Packing List... 5 Safety Precaution...

More information

ZN230-24MP-1 MP-BUS

ZN230-24MP-1 MP-BUS Actuators for heating, ventilation, air conditioning.. 4.. 6. ZN0-4- Product Information -Bus Power Unit # s-009-e- -BUS ZN0-4 ZN0-4 ZN0-4 Subject to technical changes 04090 / / -Bus Power Unit ZN0-4 Contents

More information

Time Counters mini "h", DC Version

Time Counters mini h, DC Version Type 633-DC Time Counters mini "h", DC Version Type 633.0 Type 633.7 Type 633.8 High shock resistance Miniature dimensions Electrical connections in standard grid Suitable for PCB mounting Machine-solderable

More information

See instructions to download and install the latest version of LinkBoxLON and the user's manual at

See instructions to download and install the latest version of LinkBoxLON and the user's manual at Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any

More information

User Manual. cmt-svr Startup Guide

User Manual. cmt-svr Startup Guide User Manual cmt-svr Startup Guide Table of Contents Chapter 1 Overview... 1 1.1 Specification... 1 1.2 Dimensions... 2 1.3 Connector pin designations... 3 1.4 USB host port and SD card slot... 3 1.5 Ethernet

More information

DM650VI SENSOR/WALL MOUNTED VOLTAGE/mA DISPLAY

DM650VI SENSOR/WALL MOUNTED VOLTAGE/mA DISPLAY ±50 V / ±50 ma INPUT (loop impedance < 30 R) ALARM RELAY / USER SET DISPLAY MESSAGING USB AND NFC INTERFACE BATTERY POWERED 5000 POINT DATA LOGGER INTRODUCTION The DM650VI is a battery powered indicator.

More information

Industrial Serial RS-232 to Fiber Converter. KSC-200 Series. Installation Guide

Industrial Serial RS-232 to Fiber Converter. KSC-200 Series. Installation Guide Industrial Serial RS-232 to Fiber Converter KSC-200 Series Installation Guide DOC.100803-KSC-200-1- (C) 2006 KTI Networks Inc. All rights reserved. No part of this documentation may be reproduced in any

More information

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors UL Recognized C60N Supplementary Protectors B Curve C60N Supplementary Protectors 1 MG24110 MG24125 MG24140 MG24155 15 MG17406 MG17436 MG17461 1.2 MG17402 MG17432 16 MG24118 MG24133 MG24148 MG24163 1.5

More information

APP 700 Technical Specification

APP 700 Technical Specification Issued: 12/12 Supersedes: 4/12 Description The APP 700 hardware series are especially designed for waste and clean water systems, both in construction and functionality. The RTUs¹ are developed to meet

More information

Ethernet-Adapter for the control and the management of UPS Facilities

Ethernet-Adapter for the control and the management of UPS Facilities Version: 2015-04-15 SNMP / WEB MANAGER CS141 External & Slot Cards Ethernet-Adapter for the control and the management of UPS Facilities Features High-tech made in Germany and the USA! The most powerful

More information

DKG-210 UNIVERSAL INTERNET GATEWAY UNIT

DKG-210 UNIVERSAL INTERNET GATEWAY UNIT DKG-210 UNIVERSAL INTERNET GATEWAY UNIT AC & DC SUPPLY VERSIONS DESCRIPTION The DKG-210 is designed for internet monitoring and control of industrial devices using different protocols through the RAINBOW

More information

Operating Instructions. Power Supply & Latching Relay For Switches Model: RL manual_rl-6000_1016

Operating Instructions. Power Supply & Latching Relay For Switches Model: RL manual_rl-6000_1016 Operating Instructions Power Supply & Latching Relay For Switches Model: RL-6000 manual_rl-6000_1016 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...3 5. Operating

More information

EXPANSION PERIPHERAL CVM-R10 C. (Code ) INSTRUCTION MANUAL ( M / 00 A ) (c) CIRCUTOR S.A.

EXPANSION PERIPHERAL CVM-R10 C. (Code ) INSTRUCTION MANUAL ( M / 00 A ) (c) CIRCUTOR S.A. EXPANSION PERIPHERAL CVM-R10 C (Code 7 70 217 ) INSTRUCTION MANUAL ( M 981 170 / 00 A ) (c) CIRCUTOR S.A. ------ CVM-R10 C Peripheral --------------- Pag. 1 CVM-R10C EXPANSION PERIPHERAL 1.- DESCRIPTION

More information

Multi-IQ. Firmware: RS232-Data Manager for UPS 4 x RS232 / 1 x LAN-Contacts flash upgradeable. User manual. (Serial Number / Seriennummer)

Multi-IQ. Firmware: RS232-Data Manager for UPS 4 x RS232 / 1 x LAN-Contacts flash upgradeable. User manual. (Serial Number / Seriennummer) Version: 2016-08-18 Multi-IQ Firmware: (Serial Number / Seriennummer) RS232-Data Manager for UPS 4 x RS232 / 1 x LAN-Contacts flash upgradeable User manual MANUAL ENGLISH... 2 GENERAL PROPERTIES:... 2

More information

AC-DC Converter REC K10

AC-DC Converter REC K10 Rectifier System for Telecom-, Industry- and Rail applications General Electrical Safety EN 60950, UL 94 Protection class 1 Pollution degree 2 Isolation primary secondary 3.75kVDC PFC Ventilation EN 6100-3-2,

More information

USER S MANUAL VER.2. C76- MULTIFUNCTION CNC BOARD Rev. 1.4

USER S MANUAL VER.2. C76- MULTIFUNCTION CNC BOARD Rev. 1.4 USER S MANUAL VER.2 C76- MULTIFUNCTION CNC BOARD Rev. 1.4 MARCH 2018 User s Manual Page i USER'S MANUAL TABLE OF CONTENTS Contents Page # 1.0 FEATURES... 1 2.0 I/O SPECIFICATIONS... 2 3.0 BOARD DESCRIPTION...

More information

MCX402DR-BRD I/O expander. Operating Manual

MCX402DR-BRD I/O expander. Operating Manual Roger Access Control System MCX402DR-BRD I/O expander Operating Manual Product version: 1.0 Firmware version: 1.0.2.255 Document version: Rev. B Design and application The MCX402DR-BRD is I/O expander

More information

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any

More information

HI SEC Integrated Systems

HI SEC Integrated Systems Service Note 145 HI SEC Integrated Systems Subject: New S-ART 2xx Range Ref. No.: 93014501 Service Note 145 Summary: This Service Note describes a new enhanced range of S-ART s which will replace the existing

More information

Power Input Assignment Power1 12VDC DC Jack VDC Power2 - Power Ground

Power Input Assignment Power1 12VDC DC Jack VDC Power2 - Power Ground Quick Start Guide This quick start guide describes how to install and use the Hardened Ethernet Extender. This is the Hardened Ethernet Extender of choice for harsh environments constrained by space. Physical

More information

ABL8BBU24200 battery control module V DC - 24 V - 20 A - for regulated SMPS

ABL8BBU24200 battery control module V DC - 24 V - 20 A - for regulated SMPS Characteristics battery control module - 24..28.8 V DC - 24 V - 20 A - for regulated SMPS Main Range of product Product or component type Input voltage Output voltage Maximum output current Phaseo Battery

More information

16-Way Input 48-Way Output Card

16-Way Input 48-Way Output Card 16-Way Input 48-Way Output Card Features 16 Configurable Inputs Push Button, Switch Input Fast Input Response 48 Configurable Outputs OFF, ON, 0.5S ON / 0.5S OFF, 1S ON / 1S OFF Configurable Buzzer OFF,

More information

NIEx9. Metasys. BAS network automation Supervisory controllers. Network Integration Engine

NIEx9. Metasys. BAS network automation Supervisory controllers. Network Integration Engine Virtual Branch ecatalogue click here Metasys Network Integration Engine Network Integration Engines (s) for 3 rd party integrations enable Internet Protocol (IP) connectivity and Web-based access to Metasys

More information

5 / 8 Port Gigabit Ethernet Industrial Switches Entry Line

5 / 8 Port Gigabit Ethernet Industrial Switches Entry Line Product Overview 5 / 8 Port Gigabit Ethernet Industrial Switches Entry Line Description The new Gigabit Ethernet industrial switch offers the full Gigabit performance on all ports. This offers, beside

More information

DIO-1616LN-FIT. Features. Specifications. Ethernet Remote I/O F&eIT N Series Isolated Digital Input/Output Unit DIO-1616LN-FIT 1. Ver.1.

DIO-1616LN-FIT. Features. Specifications. Ethernet Remote I/O F&eIT N Series Isolated Digital Input/Output Unit DIO-1616LN-FIT 1. Ver.1. Ethernet Remote I/O F&eIT N Series Isolated Digital / DIO-1616LN-FIT * Specifications, color and design of the products are subject to change without notice. This product is an isolated digital input and

More information

EX-RC1 Remote I/O Adapter

EX-RC1 Remote I/O Adapter EX-RC1 Remote I/O Adapter The EX-RC1 interfaces between Unitronics Vision OPLCs and remote I/O Expansion Modules distributed throughout your system. The adapter is connected to a PLC via CANbus. Each adapter

More information

ICPDAS FSM-510G Series Ethernet Management Switch Quick Start

ICPDAS FSM-510G Series Ethernet Management Switch Quick Start ICPDAS FSM-510G Series Ethernet Management Switch Quick Start Version 1.0, Dec 2014 Overview The Management Ethernet Switch solutions are designed for supporting standard industrial applications. Managed

More information

Gateway configuration manual IP - KNX EK-BE1-TP

Gateway configuration manual IP - KNX EK-BE1-TP IP - KNX EK-BE1-TP Index Scope of the document... 3 1 Product description... 3 1.1 Main functions... 4 1.2 Technical data... 4 1.3 Supply... 5 1.4 System requirements for configuration software... 5 1.5

More information

Connecting a Cisco Output Module

Connecting a Cisco Output Module CHAPTER 5 Overview The optional Cisco Output Module (Figure 5-1) is attached to a Cisco Physical Access Gateway or Cisco Reader Module to provide additional connections for up to 8 outputs, each of which

More information

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO Order Number: 8160.UISO Status: V3; 17.09.2010c G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany 1 TABLE OF CONTENTS PLEASE READ BEFORE USE... 3 DESCRIPTION... 5 UMB ISO CONVERTER ISOCON... 6 CONFIGURATION...

More information

Article no. BWU2045: AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input 1.23 NC

Article no. BWU2045: AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input 1.23 NC Safety + standard I/O in one module AS-i Safety relay output with galvanically isolated contact sets, approved up to 230 V IEC 61508 SIL 3, EN ISO 13849-1/PLe Kat 4, EN 62061 SIL 3 Protection category

More information

CONTROL MICROSYSTEMS and 5407 Relay Output Module. Hardware Manual

CONTROL MICROSYSTEMS and 5407 Relay Output Module. Hardware Manual 506 and 507 Relay Output Module Hardware Manual CONTROL MICROSYSTEMS SCADA products... for the distance Steacie Drive Telephone: 63-59-93 Kanata, Ontario Facsimile: 63-59-0 KK A9 Technical Support: -6-676

More information

ABB i-bus EIB. Shutter Actuator, 2-fold, 6 A, 230 VAC, MDRC JA/S 2.6.1, GH Q R0111

ABB i-bus EIB. Shutter Actuator, 2-fold, 6 A, 230 VAC, MDRC JA/S 2.6.1, GH Q R0111 , GH Q31 0022 R0111 The 2-fold shutter actuator is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via a bus connecting terminal. It is used to control two

More information

Quick Start Guide. Physical Description. The Port Status LEDs

Quick Start Guide. Physical Description. The Port Status LEDs Quick Start Guide This quick start guide describes how to install and use the Hardened PoE Ethernet Switch. Capable of operating at temperature extremes of -40 C to +75 C, this is the switch of choice

More information

Diagnostics (Logical) Diagnostics (Physical)

Diagnostics (Logical) Diagnostics (Physical) Enclosure Mounted Input/Output Stations In-Cabinet I/O IP 20 Protection Ideal for Retrofits Automatic Baud Rate Sensing FDN20-4S-4XSG FDN20-4S-4XSG-E* FDN20-4S-4XSG-DIN* * Not UL Electrical Operating Current:

More information

UPS Series. features: uninterruptible power supply. what great systems are built on.

UPS Series. features: uninterruptible power supply. what great systems are built on. uninterruptible power supply uninterruptible power supply with energy saver design that is optimized to address the needs of A/V systems features: Pure Sine Wave technology with Automatic Voltage Regulation

More information

Industrial Media Converters

Industrial Media Converters Wireless AP Industrial s Introduction & Features Fiber s Ethernet s Serial s s Distance Extension With Higher Immunity Introduction The media converters have incorporated SUNIX advanced technologies such

More information

1 Description. 2 Specifications. Product Installation Document. Honeywell 12 Clintonville Road Northford, CT

1 Description. 2 Specifications. Product Installation Document. Honeywell 12 Clintonville Road Northford, CT Honeywell 12 Clintonville Road Northford, CT 06472 http://www.honeywellpower.com HP600ULACM4CB HP600ULACM8CB Access Control Power Supply/Charger with Power Distribution Controller PN 52395:A 1/05/06 ECN

More information

The INJ-102GT-24V PoE Injector is an advanced IEEE802.3at compliant device with intelligent detection that provided

The INJ-102GT-24V PoE Injector is an advanced IEEE802.3at compliant device with intelligent detection that provided Industrial 2-port Gigabit High Power PoE Injector, 24V~50V Input Support Features Supports 2x10/100/1000Base-T(X) for power and data Output Fully compliant with IEEE802.3at/802.3af standard Auto protection

More information

EX-RC1 Remote I/O Adapter

EX-RC1 Remote I/O Adapter EX-RC1 Remote I/O Adapter The EX-RC1 interfaces between Unitronics Vision OPLCs and remote I/O Expansion Modules distributed throughout your system. The adapter is connected to a PLC via CANbus. Each adapter

More information

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any

More information

iologik 4000 Series Modular remote I/O Introduction iologik E4200 Specifications Remote I/O Slice Form Factor and Flexible I/O Variety

iologik 4000 Series Modular remote I/O Introduction iologik E4200 Specifications Remote I/O Slice Form Factor and Flexible I/O Variety iologik 4000 Series Modular remote I/O I/O expansion without a backplane Supports SNMPv1/v2c Active communications with MX-AOPC UA Server Easy configuration with Modular ioadmin utility Friendly configuration

More information

Z-LINE Z201 Z-L LINE. AC Current. to DC ma/v isolator/converter CONVERTERS AND INTERFACES. Electric parameters conv verters

Z-LINE Z201 Z-L LINE. AC Current. to DC ma/v isolator/converter CONVERTERS AND INTERFACES. Electric parameters conv verters CONVERTERS AND INTERFACES AC Current Z-LINE Z201 to DC ma/v isolator/converter Z-L LINE Electric parameters conv verters INPUT:N.1 channel current 0..5 Aac or 0..10 Aac OUTPUT:N.1 channel current 0..20,

More information

DCC-8 DIGITAL TO EIGHT CURRENT LOOP CONVERTER OPERATING MANUAL

DCC-8 DIGITAL TO EIGHT CURRENT LOOP CONVERTER OPERATING MANUAL DCC-8 DIGITAL TO EIGHT CURRENT LOOP CONVERTER OPERATING MANUAL 1 TABLE OF CONTENTS 1. MOUNTING INSTRUCTIONS 1.1 Standard DIN Rail mounting 1.2 Screw Mounting 2. FUSE REPLACEMENT 3. ASSEMBLING THE UNIT

More information

1. Short description. 2. Features. 3. Technical parameters

1. Short description. 2. Features. 3. Technical parameters 1. Short description TCW122B-RR is a remote relay control module with embedded WEB server for set up. The device has two digital inputs and two relays, with normally open and normally closed contacts.

More information

MGate MB3170/MB3270 Quick Installation Guide

MGate MB3170/MB3270 Quick Installation Guide MGate MB3170/MB3270 Quick Installation Guide Edition 7.1, February 2016 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777 Fax: 1-714-528-6778

More information

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

See instructions to download and install the latest version of LinkBoxMB and the user's manual at Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any

More information

PTC-101 Quick Installation Guide

PTC-101 Quick Installation Guide PTC-101 Quick Installation Guide Moxa Industrial Media Converter Edition 5.1, November 2017 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777

More information

BMKC Controller for Parabolic Trough application without encoder, 8 In 8 Out 4 AI

BMKC Controller for Parabolic Trough application without encoder, 8 In 8 Out 4 AI Characteristics Controller for Parabolic Trough application without encoder, 8 In 8 Out 4 AI Main Range of product Product or component type Product specific application Complementary Product compatibility

More information

Multifunction Transducer MT440

Multifunction Transducer MT440 Multifunction Transducer MT440 Voltage and current auto range measurements up to 600V, 12.5A Universal wide auxiliary power supply range 24 300 Vdc, 40 276 Vac Power accuracy class 0.5 (EN 60 688), Up

More information

Artistic Licence. Rail-Switch II. User Guide. Rail-Switch II User Guide. Version 5-5

Artistic Licence. Rail-Switch II. User Guide. Rail-Switch II User Guide. Version 5-5 Artistic Licence Rail-Switch II User Guide Version 5-5 Please read these instructions before using the product. This product has been designed & manufactured for professional use only. It should only be

More information

NEUROLOGIC RESEARCH CORPORATION MODEL 2150

NEUROLOGIC RESEARCH CORPORATION MODEL 2150 NEUROLOGIC RESEARCH CORPORATION FOUR DIGITAL INPUT / FOUR DIGITAL OUTPUT NETWORK NODE - Very compact design available in DIN Rail and NEMA 4X enclosures. - LonWorks FTT-10A network interface with all inputs

More information

Message Runner KP3H. Text Display. Small messages on your machine. Compact DIN 36 x 72 profile. Green and orange character display.

Message Runner KP3H. Text Display. Small messages on your machine. Compact DIN 36 x 72 profile. Green and orange character display. Message Runner KP3H Text Small messages on your machine This small and compact display is extremely well-suited for indicating a variety of short messages. Compact DIN 36 x 7 profile The compact DIN 36

More information

User Manual Digital Input Module

User Manual Digital Input Module EH-RIO2 Series RIO2-XDP4, -XDP8, -XDP16, -XAH4 Version 1.04 Copyright Hitachi Europe GmbH 2015. All rights reserved. DOCUMENT CHANGE SUMMARY REV PAGE REMARKS DATE EDITOR 1.4 All Created 18.06.2015 Winter

More information

EX-RC1 Remote I/O Adapter

EX-RC1 Remote I/O Adapter EX-RC1 Remote I/O Adapter The EX-RC1 interfaces between Unitronics Vision OPLCs and remote I/O Expansion Modules distributed throughout your system. The adapter is connected to a PLC via CANbus. Each adapter

More information

INSTRUCTION MANUAL. SIL 3 Switch/Proximity Detector Repeater Relay Output, Termination Board Models D6032S, D6032D

INSTRUCTION MANUAL. SIL 3 Switch/Proximity Detector Repeater Relay Output, Termination Board Models D6032S, D6032D D603S D603D INSTRUCTI MANUAL SIL 3 Switch/Proximity Detector Repeater Relay, Termination Board Models D603S, D603D D603 SIL 3 Switch/Proximity Detector Repeater Relay G.M. International ISM0400 General

More information

IBS ST (ZF) 24 BK LB-T

IBS ST (ZF) 24 BK LB-T . - IBS ST (ZF) 24 BK LB-T Bus Terminal Module With Local Bus Branch Data Sheet 5049B 09/1999 5049B000 ' " # " % 1 6-4 * 7 5 7 4 + * ) * ) - -,, 4, 4 A? BEC K H= JE 7 5 * K I 6 A H E = " 8, + @ K A 1@

More information

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS MAINTENANCE MANUAL EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS SPECIFICATIONS*... 2 INTRODUCTION... 3 DESCRIPTION...

More information

INJ-24A Series Quick Installation Guide

INJ-24A Series Quick Installation Guide INJ-24A Series Quick Installation Guide Moxa High-Power PoE+ Injector Edition 4.1, August 2017 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777

More information

S SENECA. Installation Manual Z-TWS4. Z-PC Line. Web Multifunction Controller Straton / Linux

S SENECA. Installation Manual Z-TWS4. Z-PC Line. Web Multifunction Controller Straton / Linux S SENECA Z-PC Line EN Installation Manual Contents: - General specifications - Technical features - Modbus and CANopen connections - Installation rules - Electrical connections - LEDs signallings - Default

More information

Power Input Assignment Power1 12VDC DC Jack VDC Power2 - Power Ground

Power Input Assignment Power1 12VDC DC Jack VDC Power2 - Power Ground Quick Start Guide This quick start guide describes how to install and use the Hardened Ethernet Extender. The Hardened Ethernet Extender introduced here provides one channel for Ethernet over existing

More information

Assembly and operating instructions DULCOMARIN II, N-Module (Power Supply Module without Relay) DXMaN

Assembly and operating instructions DULCOMARIN II, N-Module (Power Supply Module without Relay) DXMaN Assembly and operating instructions DULCOMARIN II, N-Module (Power Supply Module without Relay) DXMaN Please enter the identity code of your device here! DXMa _ Please carefully read these operating instructions

More information

PLEASE READ INSTRUCTIONS CAREFULLY BEFORE INSTALLATION!

PLEASE READ INSTRUCTIONS CAREFULLY BEFORE INSTALLATION! TUC2 / TUCH2 Model Series Installation Instructions PLEASE READ INSTRUCTIONS CAREFULLY BEFORE INSTALLATION! APPLICATION The TUC2 provides temperature space monitoring with a backlit LCD. The TUCH2 provides

More information

ISO 9001 CERTIFIED. 607 NW 27th Ave Ocala, FL Phone: (352) or Fax: (352) SUITABLE FOR EXTERNAL DISTRIBUTION

ISO 9001 CERTIFIED. 607 NW 27th Ave Ocala, FL Phone: (352) or Fax: (352) SUITABLE FOR EXTERNAL DISTRIBUTION ISO 9001 CERTIFIED Phone: (352) 629-5020 or 800-533-3569 Fax: (352)-629-2902 ES-Key 12- Relay Board P/N 103190 and 103338 PAGE 1 of 13 1. REVISI LOG... 2 2. OVERVIEW... 3 2.1. PART NUMBERS... 3 2.2. MODULE

More information

MasterFlux 48V Cascade BLDC Motor Controller Product Specification 030F0137

MasterFlux 48V Cascade BLDC Motor Controller Product Specification 030F0137 MasterFlux 48V Cascade BLDC Motor Controller Product Specification 030F0137 Revision History Page 1 of 11 Date ECN Rev Description By 09/01/10 EC34869 A Initial Release D. Stahl 07/14/11 EC39745 B Updated

More information