Page 1. Universal controller for solar energy systems with one collector array and one storage reservoir COMMISSIONING MANUAL

Size: px
Start display at page:

Download "Page 1. Universal controller for solar energy systems with one collector array and one storage reservoir COMMISSIONING MANUAL"

Transcription

1 Page 1 Universal controller for solar energy systems with one collector array and one storage reservoir COMMISSIONING MANUAL

2 Page 2 Contents! Contents Note! Before beginning assembly or installation work, first read this commissioning manual and familiarise yourself with its content in full! The safety instructions and working instructions in the operating manual must also be observed! Take note of the s which you make, at the respective places provided for this purpose in this commissioning manual and in the operating manual! 1. Product description Features and functions Technical data Safety instructions Transport and storage Installing and connecting the controller Proceed as follows step by step Possible additional functions Relay connector assignment Sensor connector assignment Installing the controller Electrical connections Installing the collector sensor and storage reservoir sensor Dismantling and disposal Commissioning the controller Front view of the controller with buttons and display Structure of the start display The specialised mechanic level Structure of submenus and navigation Reset of the factory System layout (1 collector array, 1 storage reservoir, 1 pump) Pump blockage protection Setting the additional functions Additional function: low flow Additional function: collector monitoring / tube function Additional function: emergency collector switch-off Additional function: collector safety Additional function: storage reservoir safety Additional function: collector frost protection Additional function: thermostat, e.g. for activation of the circulation pump Additional function: temperature comparison System information menu Overview of all s Relay test submenu REL Faults and troubleshooting...18

3 Product description Page 3 1. Product description Your solar controller is a microprocessor-based controller, for control of solar energy systems with one collector array and one storage reservoir. The pump is controlled so as to optimise the heat energy obtained from the solar collector array, according to the solar irradiation and the temperatures which arise in the solar energy system. With the heat energy thus obtained, one storage reservoir can be loaded, e.g. a domestic water storage tank or a swimming pool Features and functions Large illuminated display (LCD) with universally understandable symbols All key system data at a glance Easy operation and programming Modern design in a compact housing for wall-mounting Predefined system layout Temperature difference control of a solar energy system with one collector array and one storage reservoir Low-flow concept for optimal stratified loading Frost protection function and protection from overheating for collectors and storage reservoirs Thermostat and temperature comparison System diagnostics

4 Page 4 Technical data 2. Technical data Supply voltage Power consumption Fuse Inputs 230 V AC 50 Hz 2.4 VA 1.6 AT, microfuse 5 mm x 20 mm 4 inputs: temperature sensor: Pt1000 (-20 C to +150 C) Outputs 2 electromechanical relays: each 1 A, 250 V AC (ε) Protection degree IP 20 as per DIN EN (VDE ) Mode of operation type 1 Y (as per DIN EN ) Insulation class 2 Ambient temperature 0 C to + 50 C Power reserve Installation Housing Dimensions Weight Conformity 3. Safety instructions DANGER > 10 years at + 20 C, with lithium battery wall-mounted plastic, PC / ABS 170 mm x 170 mm x 55 mm 0.65 kg The solar controller meets the requirements of the Electromagnetic Compatibility Directive (2004/108/EC), the Low Voltage Directive (2006/95/EC) and the harmonised standards DIN EN and DIN EN It bears the CE label. Danger of electrocution! The controller is to be assembled, electrically installed, commissioned, inspected and repaired by trained, competent and authorised persons (qualified electricians as per DIN VDE and BGV A3) only! Observe all applicable guidelines and regulations of the local electricity supplier! Before beginning installation or repair work on electrical equipment, always ensure complete disconnection from the mains and secure against reactivation! Do not work on live parts! The controller may only be installed and operated in: dry environments which are not potentially explosive closed rooms rooms with a temperature between 0 C and + 50 C

5 Transport and storage Page 5 4. Transport and storage Thoroughly check whether the packaging or the controller shows any sign of damage. Transport the controller in the original packaging only. If the controller falls, even from a low height, it may get damaged. Prevent impact and extreme temperatures (below 0 C or above + 50 C) during transport and storage. The controller may only be stored in its original packaging and in a dry environment. 5. Installing and connecting the controller 5.1. Proceed as follows step by step 1. Check whether you wish to use additional functions (see 5.2. Possible additional functions and 10. Setting the additional functions [the individual additional functions are explained here]). 2. Check whether the desired additional functions can be realised, i.e. whether there are free sensors and relays for the functions (see 5.3. Relay connector assignment and 5.4. Sensor connector assignment). 3. Install the controller at a suitable location and realise the electrical connections (see 5.6. Installing the controller and 5.7. Electrical connections). 4. Install the required sensors (see 5.8. Installing the collector sensor and storage reservoir sensor). 5. Connect the required sensors to the controller and assign the relays according to your requirements (see 5.3. Relay connector assignment and 5.4. Sensor connector assignment). 6. Switch on the controller by pressing and holding the esc button for at least 5 seconds. 7. Familiarise yourself with the controller s menu navigation (see 6.1. Front view of the controller with buttons and display and the detailed description in the operating manual). 8. Configure any additional functions (see 10. Setting the additional functions). 9. Record your s in the respective sections of this commissioning manual under Selection (10. Setting the additional functions).

6 Page 6 Installing and connecting the controller 5.2. Possible additional functions This table shows you the additional functions which can be used. One relay can be assigned individually. Funktion Low-Flow Collector monitoring / tube function Collector safety function Collector frost protection function Storage reservoir safety function * Thermostat function (circulation pump)* / ** Temperature comparison function* / ** * Free relay required Described in section ** For these functions, it is also possible to use a relay which is already assigned Relay connector assignment A solar pump must be connected to relay R1. The relay R2 is free and can be assigned individually.! Note! Safety extra-low voltage is not to be connected with the relays on the high-voltage side (R1 to R2) Sensor connector assignment The following table shows whether the selected additional functions can be realised: F1 F2 F3 F4 must be connected to the collector array is free and can be assigned individually can be connected to the upper part of the storage reservoir, otherwise it can be assigned individually must be connected to the lower part of the storage reservoir For the additional functions thermostat and temperature comparison the sensors can be configured freely and activated on the specialised mechanic level.

7 Installing and connecting the controller Page Installing the controller Upper fastening hole (for hanging) esc - + ok 130mm 140mm Terminal cover Lower fastening holes 1. Choose a suitable installation location. 2. Remove the collector s terminal cover. 3. Mark and drill (Ø 6 mm) the central upper fastening hole. Insert the provided rawlplug and a screw. 4. Hang the controller on the screw and align it. 5. Mark the lower fastening holes (140 mm between holes). Remove the controller once more. 6. Drill the two lower holes (Ø 6 mm). 7. Insert rawlplugs and hang up the controller once more. 8. Screw the controller firmly in place at the two fastening holes. Risk of injury! Do not use the controller as a drilling template! DANGER Connection diagram 5.7. Electrical connections Danger of electrocution! Every time the terminal cover is opened, the controller is to be disconnected from the power supply beforehand! Ensure that it cannot be reactivated! The type of current (alternating current) and the voltage must match the specifications in the connection diagram. Connect the controller as shown in the connection diagram. DANGER

8 Page 8 Installing and connecting the controller Electrical connections are to be realised with screw terminals (single wire / fine wire, max. 1.5 mm²). The mains supply s protective earth connector is to be connected to the 5-pole terminal block ( ). Protective earth connection of loads (pumps etc.) is to be realised at the 5-pole terminal block provided for this purpose. In so doing, it must be ensured that the mains supply s protective earth connector is also connected to this terminal block. Each terminal may only be connected to one connecting wire. Adequate strain relief must be ensured! Only use the Pt1000 temperature sensors approved for use with the controller. All cables which carry low voltage (e.g. sensor cables) are to be routed in such a way that they are kept separate from cables which carry mains voltage. The polarity of the sensor cables is arbitrary.! Note! Safety extra-low voltage is not to be connected with the relays on the high-voltage side (R1 to R2). After the electrical connection work, replace the terminal cover Installing the collector sensor and storage reservoir sensor! Note! Do not route sensor cables together with cables which carry more than 50 V (low voltage)! Shield sensor cables sufficiently. Thermally insulate sensors and piping. Installing the collector sensor: Insert the collector sensor into the provided opening on the collector array and fasten it in place (refer to the installation instructions from the collector manufacturer). Installing the storage reservoir sensor: Insert the storage reservoir sensor into the provided opening at the storage reservoir and fasten it in place (refer to the installation instructions from the storage reservoir manufacturer). Sensor cables can be extended to a maximum length of 100 m.! Note! As temperatures of up to + 90 C arise in the domestic water storage reservoir, a thermal hot water mixer must be installed (German Heating Installation Regulation HeizAnlV 8 para. 2)! In order to protect the storage reservoir from high temperatures, or to limit loading to the storage reservoir s maximum temperature, the collector safety function (KSF) can be set to no on the operating level E3-6 / Dismantling and disposal DANGER Danger of electrocution! Disconnect the controller from the power supply before dismantling! Ensure that it cannot be reactivated! To dismantle the controller, follow the installation instructions in reverse order. Disposal must comply with the German Electrical and Electronic Equipment Act (ElektroG), which governs the sale, return and environmentally sound disposal of electrical and electronic equipment.

9 Commissioning the controller Page 9 6. Commissioning the controller 6.1. Front view of the controller with buttons and display OK + : Apply current Open a submenu } : On the normal level: Select a submenu Within a menu: Scroll : For s: Change value esc : Return to previous menu Discard change and restore previous value Delete input Note! If OFF appears in the display, the controller has been switched off. Switch the controller back on by pressing and holding the esc button for at least 5 seconds. As soon as the start display appears, the controller has been reactivated. In order to switch off the controller, press and hold the esc button for another 5 seconds Structure of the start display! Please note that other symbols or values which are not pictured above can also appear in your controller s start display.

10 Page 10 The specialised mechanic level 7. The specialised mechanic level The specialised mechanic level contains the s which must be set during commissioning (possibly only once). To open the specialised mechanic level, press and hold the buttons + and simultaneously for five seconds while in the normal start display. To enter the various sublevels (E3-1 to E3-10), use the + or button. Press the OK button to view the sublevels s.! Note! Settings which deviate from the factory s are indicated by flashing underscore lines. These disappear if the value is set to the factory once more Structure of submenus and navigation Several functions can be set within each submenu. These functions are numbered sequentially and marked by the symbol N O. This numbering can be found in the tables regarding configuration of the system layout and additional functions (e.g.: E3-3 / 2): Example: E3-3 = number of the submenu N_ = number of the function = change value 65 C = set value TCS = function s identifier In the submenu, scroll through the individual values with the buttons + and. If you wish to change a value, press the button. The symbol appears in the display. Change the value with the buttons + and. Press the OK button to apply the new value. Pressing esc discards the new value; the original value then reappears in the display. In a submenu, only those values possible in the selected configuration are displayed. Relays and sensors can only be allocated if they have not already all been assigned. To leave a menu, press the esc button. OK

11 Reset of the factory Page Reset of the factory Open the specialised mechanic level (press and hold the buttons + and simultaneously for five seconds) and use the + or button to select the sublevel E3-1. Confirm your selection with OK. In the display RES appears. Press the button OK to reset the factory. When the symbol appears in the display, the adjustment or the shown value can be changed System layout (1 collector array, 1 storage reservoir, 1 pump) Description of the system layout: The solar controller compares the temperature from collector sensor F1 (TC) with the temperature from the storage reservoir sensor F4. If the measured temperature difference exceeds the switch-on temperature difference TDE the speed-controlled solar pump R1 is switched on and the storage reservoir is loaded. R1 F1 (F3) F4 The following s are possible in this system layout: Level Display Function Factory AE MAX Maximum loading temperature MAX for the storage reservoir. AE SPA Activation/deactivation of the storage reservoir Range 70 C 10 C to 90 C YES YES / no E3-1 / 1 RES Reset of the factory. no YES / no E3-1 / 13 SSP Upper storage reservoir sensor F3 present, see section 5.4. E3-2 / 1 TDE Switch-on temperature difference between F1 and F4 (not less than switch-off temperature difference + 1 K). E3-2 / 2 TDA Switch-off temperature difference between F1 and F4 (not greater than switch-on temperature difference - 1 K). YES YES / no 8 K 1 K to 20 K 4 K 1 K to 20 K Selection Additional functions: See the overviews in section 5.2. Possible additional functions, section 5.3. Relay connector assignment and section 5.4. Sensor connector assignment. For detailed descriptions of the individual additional functions, see section 10. Setting the additional functions.

12 Page 12 Pump blockage protection 9. Pump blockage protection If the pumps have been deactivated for a long time, there is a risk that they will block when reactivated, due to accumulated dirt or limescale. In order to prevent such blockages, the pumps are switched on for 10 seconds at a certain time each day. 10. Setting the additional functions! Note! Mark the additional functions which you have selected, as follows: Additional function: low flow In order to optimise the loading process, loading of the selected storage reservoir is only enabled once the collector temperature TCS (which is set here) is reached. When selecting this function, it is important to ensure that the loading pumps minimum speeds are set to values below 100%, i.e. that speed control is possible. Level Display Function Factory Range E3-3 / 1 LFF Activation of low-flow function. no YES / no E3-3 / 2 TCS Collector temperature which enables loading of the selected storage reservoir Additional function: collector monitoring / tube function 65 C 10 C to 90 C Selection The collector s temperature is monitored. If the measured temperature exceeds the value TCW (which is set here) and if the length of time defined by the PAUS has passed without the solar pump operating, the solar pump is switched on for the length of time defined by the PAN. Level Display Function Factory Range E3-3 / 4 CW Activation of the collector monitoring function. no YES / no E3-3 / 5 TCW Minimum collector temperature 35 C 10 C to 90 C during monitoring. E3-3 / 6 PAN Solar pump s runtime. 10 sec. 10 sec. to 60 sec. E3-3 / 7 PAUS Solar pump s idle time. 60 min. 10 min. to 60 min. Selection

13 Setting the additional functions Page Additional function: emergency collector switch-off If collector temperature exceeds the maximum value NOT (which is set here) for longer than 5 minutes, the solar pump is switched off and will not resume operation until the collector temperature has fallen below NOT - 10 K. Level Display Function Factory Range E3-6 / 1 NOT Emergency collector switch-off 110 C 90 C to 127 C Selection Additional function: collector safety If the collector temperature exceeds the maximum value TCM (which is set here), the storage reservoir shall be loaded until the emergency storage reservoir switch-off temperature is reached (fixed value: 90 C). Level Display Function Factory Range E3-6 / 2 KSF Activation of the collector safety YES YES / no function. E3-6 / 3 TCM Maximum temperature for 90 C 10 C to 127 C collector (above which the collector safety function is activated automatically) Additional function: storage reservoir safety Selection If the storage reservoir temperature (F3) exceeds the maximum storage reservoir loading temperature MAX (which is set on the user level) by 2 K, heat is dissipated out of the storage reservoirs (e.g. into the heating system). Level Display Function Factory Range E3-6 / 4 SSF Selection of relay for the storage 0 0 to 2 reservoir safety function. 0: no relay allocated (function is not enabled) 1 to 2: relay is allocated (function is enabled) Additional function: collector frost protection Selection If the collector temperature falls below the frost protection temperature of + 2 C, the solar pump is activated until the collector has been heated to + 5 C by the storage reservoir water. Level Display Function Factory E3-6 / 5 FSF Activation of the collector frost protection function. no Range YES / no Selection

14 Page 14 Setting the additional functions Additional function: thermostat, e.g. for activation of the circulation pump The sensor input and relay output are freely selectable. Additional function Level Display Function Factory Range E3-7 / 1 STH Selection of sensor for the 0 0 to 4 thermostat function. The number of any sensor which is still free is accentuated by flashing underscore lines. If the selected sensor is already assigned to another function, the corresponding number is displayed within brackets. 0: no sensor allocated (function is not enabled) 1 to 4: sensor is allocated (function is enabled) E3-7 / 2 RTH Allocation of relay for the thermostat 0 0 to 2 function. Any relay can be selected. If the selected relay is already assigned, the functions are combined in an OR relationship. E3-7 / 3 ETH Switch-on temperature for the 40 C 10 C to 127 C thermostat function. E3-7 / 4 ATH Switch-off temperature for the 45 C 10 C to 127 C thermostat function. Selection

15 Setting the additional functions Page Additional function: temperature comparison Sensor inputs and relay outputs can be freely selected for an additional temperature comparison function. Level Display Function Factory Range E3-8 / 1 VSA Selection of the first sensor 0 0 to 4 input. 0: no sensor allocated (function is not enabled) 1 to 4: sensor is allocated (function is enabled) The number of any sensor which is still free is accentuated by flashing underscore lines. If the selected sensor is already assigned to another function, the corresponding number is displayed within brackets. E3-8 / 2 VSB Selection of the second sensor 0 0 to 4 input (see above). E3-8 / 3 VR Selection of the relay output. 0 0 to 2 Any relay can be selected. If the selected relay is already assigned, the functions are combined in an OR relationship. E3-8 / 4 VDE Switch-on temperature difference 2 K 1 K to 20 K for the temperature com- parison function (cannot be set to less than VDA + 1 K). E3-8 / 5 VDA Switch-off temperature difference 1 K 1 K to 20 K for the temperature com- parison function (cannot be set to greater than VDE - 1 K). Selection

16 Page 16 System information menu 11. System information menu Here, you can read information about the solar controller and define system s. Level Display Function Factory E3-10 / 1 SOF Display of software version. E3-10 / 2 HAR Display of hardware version. E3-10 / 3 LP Display of circuit board version. E3-10 / 7 SER Setting for service operation / normal operation. no: normal operation (all temperature filter functions are switched on) YES: service operation (all temperature filter functions are switched off) no Range YES / no Selection

17 Overview of all s Page Overview of all s Level Display Function AE MAX Maximum loading temperature MAX for the storage reservoir. Factory Range 70 C 10 C to 90 C AE SPA Activation/deactivation of the storage reservoir YES YES / no E3-1 / 1 RES Reset of the factory. no YES / no E3-1 / 13 SSP Upper storage reservoir sensor F3 present. YES YES / no E3-2 / 1 TDE Switch-on temp. difference between F1 and F4. 8 K 1 K to 20 K E3-2 / 2 TDA Switch-off temp. difference between F1 and F4. 4 K 1 K to 20 K E3-3 / 1 LFF Activation of low-flow function. no YES / no E3-3 / 2 TCS Collector temperature which enables loading of the 65 C 10 C to 90 C selected storage reservoir. E3-3 / 4 CW Activation of the collector monitoring function. no YES / no E3-3 / 5 TCW Minimum collector temperature during monitoring. 35 C 10 C to 90 C E3-3 / 6 PAN Solar pump s runtime. 10 sec. 10 sec. to 60 sec. E3-3 / 7 PAUS Solar pump s idle time. 60 min. 10 min. to 60 min. E3-6 / 1 NOT Emergency collector switch-off 110 C 90 C to 127 C E3-6 / 2 KSF Activation of the collector safety function. YES YES / no E3-6 / 3 TCM Maximum temperature for collector. 90 C 10 C to 127 C E3-6 / 4 SSF Selection of relay for the storage reservoir safety 0 0 to 2 function. E3-6 / 5 FSF Activation of the collector frost protection function. no YES / no E3-7 / 1 STH Selection of sensor for the thermostat function. 0 0 to 4 E3-7 / 2 RTH Allocation of relay for the thermostat function. 0 0 to 2 E3-7 / 3 ETH Switch-on temperature for the thermostat function. 40 C 10 C to 127 C E3-7 / 4 ATH Switch-off temperature for the thermostat function. 45 C 10 C to 127 C E3-8 / 1 VSA Selection of the first sensor input. 0 0 to 4 E3-8 / 2 VSB Selection of the second sensor input. 0 0 to 4 E3-8 / 3 VR Selection of the relay output. 0 0 to 2 E3-8 / 4 VDE Switch-on temperature difference for the temperature comparison function. E3-8 / 5 VDA Switch-off temperature difference for the temperature comparison function. E3-10 / 1 SOF Display of software version. E3-10 / 2 HAR Display of hardware version. E3-10 / 3 LP Display of circuit board version. E3-10 / 7 SER Setting for service operation / normal operation. 2 K 1 K to 20 K 1 K 1 K to 20 K

18 Page 18 Relay test submenu REL 13. Relay test submenu REL To navigate to the submenu for manual adjustment of relays, press + or repeatedly until REL appears in the display. Call up the relay test sublevel by pressing the OK button. This causes all outputs (relays) to be switched off! The individual relays are selected by pressing + or. Here, the relay number (1 to 2), the switching state (OFF, On) are displayed. Switching the relays (numbers 1 to 2) on or off: Once the OK button has been pressed to select the relay, the symbol appears. The relay s switching state can now be changed by pressing the buttons + and. The relay s switching state thus set will then remain in effect until the relay test level is abandoned. 14. Faults and troubleshooting If your controller ever ceases to function properly, please check the following points: 1. Power supply: If anything appears in the display, there is no problem with the power supply. If nothing appears in the display, please check the mains voltage and the device fuse. 2. Sensors and sensor cables: If realistic temperatures are shown in the display (normal display and information level), there is no problem with the sensors or sensor cables. H C appears in the event of a sensor interrupt and L C in the event of a sensor short circuit. If the displayed temperatures are unrealistic, you can use an ohmmeter to check that the resistance values correspond to those in the following table: Pt1000 temperature sensor resistance table -20 C 922 ohms 20 C 1078 ohms 60 C 1232 ohms 100 C 1385 ohms -10 C 961 ohms 30 C 1117 ohms 70 C 1271 ohms 110 C 1423 ohms 0 C 1000 ohms 40 C 1155 ohms 80 C 1309 ohms 120 C 1461 ohms 10 C 1039 ohms 50 C 1194 ohms 90 C 1347 ohms 130 C 1498 ohms 3. Switching output: If the solar controller does not switch on the appropriate loading pump, please check the relay output by means of the relay test submenu. If it is not possible to remove the fault by means of the points mentioned above, the solar controller should be replaced. DANGER Danger of electrocution! The heating controller is to be assembled, electrically installed, commissioned, inspected and repaired by trained, competent and authorised persons (qualified electricians as per DIN VDE and BGV A3) only! Observe all applicable guidelines and regulations of the local electricity supplier! Before beginning installation or repair work on electrical equipment, always ensure complete disconnection from the mains and secure against reactivation! Do not work on live parts!

19 Notes: Page 19

20 Page 20 The descriptions, performance specifications and graphics in this manual are non-binding. Subject to technical alterations. This manual may not be duplicated, distributed, altered, passed on, translated into another language or used in any other way, without the express permission of the manufacturer. The content of this manual has been carefully checked. Nevertheless, the manufacturer cannot be held liable for any errors in this manual. Furthermore, if this commissioning manual or the operating manual is not adhered to, or is only partly adhered to, the manufacturer assumes no liability for any resulting damage. Art-Nr: /11

Supplementary operating instructions for your air curtain system Controller TMC 500

Supplementary operating instructions for your air curtain system Controller TMC 500 Supplementary operating instructions for your air curtain system Controller TMC 500 (Translation of the original) Serial number: Year: Please quote this number when contacting customer service! Date 08.04.2016

More information

Operating instructions

Operating instructions SOLARTHERMIE - SOLAR THERMAL - SOLAR TÉRMICO - SOLAIRE THERMIQUE Operating instructions Temperature Difference Controller 6 inputs / outputs EN 714.884 08.15 ZO 714.884 08.15 1 Case overview Operating

More information

Operating manual Solareg II BASIC

Operating manual Solareg II BASIC Operating manual Solareg II BASIC Microcontroller-controlled temperature difference controller for solar thermal systems Explanation of the graphic symbols Attention! Symbol indicates possible dangers

More information

Operating manual Solareg II ENERGY

Operating manual Solareg II ENERGY Operating manual Solareg II ENERGY Microcontroller-controlled temperature difference controller for solar thermal systems Explanation of the graphic symbols Attention! Symbol indicates possible dangers

More information

Operating manual Solareg II BASIC DC

Operating manual Solareg II BASIC DC Operating manual Solareg II BASIC DC Microcontroller-controlled temperature difference controller for solar thermal systems Explanation of the graphic symbols Attention! Symbol indicates possible dangers

More information

Controller unit for solar thermal systems. grandis 600 SR. Installation and operating instructions

Controller unit for solar thermal systems. grandis 600 SR. Installation and operating instructions Controller unit for solar thermal systems grandis 600 SR Installation and operating instructions English version of original German installation and operating instructions Version: 1.1 January 2013 Terminology

More information

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26 E39.0.31.6C-02 Data logger for humidity temperature as of version V1.0 Operating Manual T-Logg 160 GREISINGER electronic GmbH D - 93128 Regenstauf, Hans-Sachs-Straße 26 +49 (0) 9402 / 9383-0 +49 (0) 9402

More information

Non-communicating room controllers

Non-communicating room controllers 3 882 DESIGO RXA Non-communicating room controllers RXA29.1 For fan-coil systems The RXA29.1 room controller are used for temperature control in individual rooms. For 2-pipe or 4-pipe fan-coil systems,

More information

SD1. Differential Controller. Operating and Installation Instructions F2 72.3

SD1. Differential Controller. Operating and Installation Instructions F2 72.3 SD1 Differential Controller Operating and Installation Instructions F2 72.3 i Please follow the safety information and read these Instructions carefully before putting the system into operation. Safety

More information

VR 80 Remote Control Device

VR 80 Remote Control Device For the owner and heating engineer Operating and installation manual VR 80 Remote Control Device Bus modular control system VR 80 GB Contents Contents Notes on the documentation...... 4 Other valid documents...

More information

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016 Operating instructions AS-i SmartLine module AC3200 AC3201 80237876/00 06/2016 Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Warnings used...3 2 Safety instructions...3 2.1 General...3 2.2 Target

More information

Operating instructions. Speed monitor D / / 2014

Operating instructions. Speed monitor D / / 2014 Operating instructions Speed monitor D200 80005257 / 00 05 / 2014 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5 2.2 Target group...5

More information

RAMSES D GB F NL. Installation and operating instructions Room thermostat. RAMSES 832 top2

RAMSES D GB F NL. Installation and operating instructions Room thermostat. RAMSES 832 top2 309 358 04 RAMSES RAMSES 811 top2 RAMSES 831 top2 811 9 132 831 9 132 RAMSES 812 top2 RAMSES 832 top2 812 0 132 832 0 132 GB Installation and operating instructions Room thermostat D GB F E I NL RAMSES

More information

Operating and Installation Manual. EASYLAB Expansion modules Type EM-TRF for 230 V AC mains voltage

Operating and Installation Manual. EASYLAB Expansion modules Type EM-TRF for 230 V AC mains voltage Operating and Installation Manual EASYLAB Expansion modules Type EM-TRF for 230 V AC mains voltage Type EM-TRF-USV for 230 V AC mains voltage; provides uninterruptible power supply (UPS) The art of handling

More information

Cube LAN Gateway. Operating manual BC-LGW-O-TW

Cube LAN Gateway. Operating manual BC-LGW-O-TW Cube LAN Gateway Operating manual BC-LGW-O-TW Package contents Package contents Quantity Item 1x MAX! Cube LAN Gateway 1x 1x 1x 1x 1x 3x Plug-in USB power supply USB cable Network cable Mounting accessories

More information

Controller unit for solar thermal systems. primos 600 SR. Installation and operating instructions

Controller unit for solar thermal systems. primos 600 SR. Installation and operating instructions Controller unit for solar thermal systems primos 600 SR Installation and operating instructions English version of original German installation and operating instructions Version: 1.0 February 2012 Terminology

More information

Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating instructions. Switching amplifier DN0210 DN / / 2015 Operating instructions Switching amplifier DN0210 DN0220 UK 80011079 / 00 01 / 2015 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5

More information

Quick Start Installation and User Manual

Quick Start Installation and User Manual 1 Quick Start Installation and User Manual Contents 1. Overview 2. Technical Specifications 3. Installation Mounting Electrical Installation Clamp Installation Wiring Diagrams 4. Installation Settings

More information

Controller unit for solar thermal systems. primos 200 SR. Installation and operating instructions

Controller unit for solar thermal systems. primos 200 SR. Installation and operating instructions Controller unit for solar thermal systems primos 200 SR Installation and operating instructions English version of original German installation and operating instructions Version: 1.0 February 2012 Terminology

More information

Temperature differential controller 5 inputs, 2 outputs

Temperature differential controller 5 inputs, 2 outputs Temperature differential controller 5 inputs, 2 outputs Installation and operating instructions EN 742.886 Z02 12.31 Subject to change due to technical improvements! Content General safety instructions...3

More information

GREISINGER electronic GmbH. D Regenstauf, Hans-Sachs-Straße 26. T-Logg 100. T-Logg 100 E

GREISINGER electronic GmbH. D Regenstauf, Hans-Sachs-Straße 26. T-Logg 100. T-Logg 100 E E39.0.0X.6C-03 Data logger for temperature as of version V1.3 Operating Manual T-Logg 100 T-Logg 100 T-Logg 100 E GREISINGER electronic GmbH D - 93128 Regenstauf, Hans-Sachs-Straße 26 +49 (0) 9402 / 9383-0

More information

Semi flush-mounted room temperature controllers with LCD

Semi flush-mounted room temperature controllers with LCD s 3 077 RDD310 RDE410 Semi flush-mounted room temperature controllers with LCD For heating systems RDD310 RDE410 RDD310 and RDE410 features: Operating voltage AC 230 V 2-position control with On / Off

More information

Operating instructions. Standstill monitor A / / 2011

Operating instructions. Standstill monitor A / / 2011 Operating instructions Standstill monitor A300 UK 1 2 3 4 5 6 7 8 7390337 / 01 02 / 2011 1 2 3 4 5 6 7 8 switchpoint min max pulse/min power Made in Germany ifm electronic gmbh D 45127 Essen func. I II

More information

Manual Control Unit GFC 32

Manual Control Unit GFC 32 Manual Control Unit 1400004_EN/05.2017 Index 1. Main features 3 2. Technical features 3 3. Installation guidelines 4 4. Preliminary checks 5 5. Electrical connections 5 6. Settings 6 7. Remote control

More information

SC3.6 differential controller 6 inputs, 4 outputs (3 relays, 1 potential-free switch output)

SC3.6 differential controller 6 inputs, 4 outputs (3 relays, 1 potential-free switch output) SOLARTHERMIE - SOLAR THERMAL - SOLAR TÉRMICO- SOLAIRE THERMIQUE - SOLARE TERMICO EN SC3.6 differential controller 6 inputs, 4 outputs (3 relays, 1 potential-free switch output) Installation and Operation

More information

Operating Instructions VEGAMET 381

Operating Instructions VEGAMET 381 Operating Instructions VEGAMET 381 in out Contents Contents 1 About this document... 4 1.1 Function... 4 1.2 Target group... 4 1.3 Symbolism used... 4 2 For your safety... 6 2.1 Authorised personnel...

More information

Manual Control Unit GFC 16

Manual Control Unit GFC 16 Manual Control Unit 1400003_EN/04.2017 Index 1. Main features 3 2. Tekniske data 3 3. Installation guidelines 4 4. Preliminary checks 5 5. Electrical connections 5 6. Settings 5 7. Remote 7 8. Shut down

More information

Description TR D

Description TR D Description TR D 78385 270607 Electronic double thermostat with heat curve in a DIN standard bar enclosure 1. Short Description The electronic double thermostat serves to control electric heating panels

More information

Content. Ⅰ General information 1. Ⅱ Product description 2. Ⅲ System description 3. Ⅳ Fault message 5

Content. Ⅰ General information 1. Ⅱ Product description 2. Ⅲ System description 3. Ⅳ Fault message 5 Content Ⅰ General information 1 Ⅱ Product description 2 Ⅲ System description 3 Ⅳ Fault message 5 Ⅴ Packing list 5 Ⅰ General information Intelligent controller series for solar water heating control system

More information

GREISINGER electronic GmbH. D Regenstauf, Hans-Sachs-Straße 26. T-Logg 120 W -... T-Logg 120 K -...

GREISINGER electronic GmbH. D Regenstauf, Hans-Sachs-Straße 26. T-Logg 120 W -... T-Logg 120 K -... E39.0.1X.6C-01 Data logger for standard signals as of version 1.0 Operating Instruction T-Logg 120... T-Logg 120 W -... T-Logg 120 K -... GREISINGER electronic GmbH D - 93128 Regenstauf, Hans-Sachs-Straße

More information

Digital Thermostat for drum heaters Model HCL 5536

Digital Thermostat for drum heaters Model HCL 5536 Digital Thermostat for drum heaters Model HCL 5536 Dear Customer, we would like to use this opportunity to thank you for buying this product from Friedr. Freek GmbH. Please read this document carefully

More information

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station s 3 836 3836P01 Desigo TRA PL-Link IO Block Use with PXC3 series room automation station RXM39.1 The PL-Link IO Block contains the inputs and outputs controlled by a room automation station via PL-Link.

More information

USER MANUAL VIBRATION CONTROL RMA-POWER-BOX 107/230

USER MANUAL VIBRATION CONTROL RMA-POWER-BOX 107/230 USER MANUAL VIBRATION CONTROL Version 2.2 1 IMPORTANT NOTES Electrical danger within the meaning of this documentation or the warning labels on the product itself respectively means that death, serious

More information

LCD LCDS LCDRI CONTROLLER OPERATING MANUAL

LCD LCDS LCDRI CONTROLLER OPERATING MANUAL This manual contains important safety information about installation and use of this equipment. Ignoring this information could result in injuries or damages. It is strictly forbidden to use this equipment

More information

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26 H20.0.34.6C-05 EASYBus-Sensor module for temperature from version V3.2 Operating Manual EBT 2R Content 1 INTENDED USE 2 2 GENERAL ADVICE 2 3 SAFETY INSTRUCTIONS 2 4 DISPOSAL NOTES 2 5 ASSIGNMENT 3 6 DIMENSION

More information

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A) Product and functional description also functions if the bus cable is not connected or if the bus communication fails. After a long push button action (> 2 s), the other valve group is selected. The yellow

More information

Product and functional description

Product and functional description Product and functional description The RS 520/23 shutter / blind actuator is a KNX device with one relay output. The device is installed in an AP 118 Control Module Box or an AP 641 Room Control Box. The

More information

Semi flush-mounted room temperature controllers with LCD

Semi flush-mounted room temperature controllers with LCD s 3 077 RDD310 RDE410 Semi flush-mounted room temperature controllers with LCD For heating systems RDD310 RDE410 RDD310 and RDE410 features: Operating voltage AC 230 V 2-position control with On / Off

More information

Operating instructions for RAMSES 811 top2_812 top2 and RAMSES 831 top2_832 top2

Operating instructions for RAMSES 811 top2_812 top2 and RAMSES 831 top2_832 top2 Operating instructions for RAMSES 811 top2_812 top2 and RAMSES 831 top2_832 top2 Dear client, if you have the newer device, please use page 1 to 33 RAMSES RAMSES 811 top2 RAMSES 831 top2 8119132 8319132

More information

Non-communicating room controllers

Non-communicating room controllers 3 881 DESIO RXA on-communicating room controllers For fan-coil systems RXA20.1 RXA21.1 RXA22.1 The RXA20.1, RXA21.1 and RXA22.1 room controllers are used for temperature control in individual rooms. For

More information

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications 3 834 DESIO RX Individual room controllers for fan-coil systems, chilled ceilings and radiators, with MARK-compatible bus communications RXC20.1 RXC21.1 The RXC20.1 and RXC21.1 controllers are used for

More information

Assembly and Operating Instructions Door Control

Assembly and Operating Instructions Door Control S10 GB Assembly and Operating Instructions Door Control Important information for: Fitters Electricians Users Please forward accordingly! These instructions must be kept for future reference. Assembly

More information

Manual Simatek Control Unit GFC 32

Manual Simatek Control Unit GFC 32 Manual Simatek Control Unit GFC 32 Original instructions 1400004_GB Ver. 2014.01.09 Index 1. Main features 3 2. Technical features 3 3. Installation guidelines 4 4. Preliminary checks 5 5. Electrical connections

More information

POCKET MULTIMETER Model No: MM18

POCKET MULTIMETER Model No: MM18 INSTRUCTIONS FOR: POCKET MULTIMETER Model No: MM18 Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and properly maintained,

More information

ProMinder Standard Heating System Installation Instructions

ProMinder Standard Heating System Installation Instructions IMPORTANT GUIDELINES Please read this instruction leaflet thoroughly before commencing installation. Ensure that that all the electrical installation is carried out by a fully qualified electrician and

More information

User Manual. Solar Inverter for Water Pump

User Manual. Solar Inverter for Water Pump User Manual Solar Inverter for Water Pump SP Revival Series Version: 1.2 Table Of Contents ABOUT THIS MANUAL... 1 Purpose... 1 Scope... 1 SAFETY INSTRUCTIONS... 1 Inspection... 1 Installation... 1 Operation...

More information

Manual Control Unit GFCD 16

Manual Control Unit GFCD 16 Manual Control Unit 1400002_EN/04.2017 Index 1. Main features 3 2. Technical features 3 3. Installation guidelines 4 4. Preliminary checks 5 5. Electrical connections 5 6. Filter taps 5 7. Settings 6 8.

More information

Temperature controller Ducted systems

Temperature controller Ducted systems 2 725 Temperature controller Ducted systems Standard model without zoning functions RRV851 Multifunctional controller used for central control of ducted HVAC systems in combination with a QAX850 master

More information

Valid for item nos.: (1-zone) (2-zone) (4-zone) (6-zone) HPS-C-Slot Hotrunner controllers Operating manual

Valid for item nos.: (1-zone) (2-zone) (4-zone) (6-zone) HPS-C-Slot Hotrunner controllers Operating manual Valid for item nos.: 68030.001 (1-zone) 68030.002 (2-zone) 68030.004 (4-zone) 68030.006 (6-zone) HPS-C-Slot Hotrunner controllers Operating manual 2 Content Safety instructions...3 Introduction...4 Operating

More information

OEM. Room unit QAA822 with2- wire interface. Building Technologies CLIMATIX TM. For use with Climatix controllers

OEM. Room unit QAA822 with2- wire interface. Building Technologies CLIMATIX TM. For use with Climatix controllers OEM CLIMATIX TM Room unit QAA822 with2- wire interface For use with Climatix controllers Remote control of air conditioning unit Mandík Measurement of the room temperature Buttons for starting, setting

More information

Operating Instructions

Operating Instructions TPS S1 AC in DC out Translation of the original instructions TPS 110-400 Mains pack Operating Instructions PT 0199 BEN/C (1010) EN Table of contents Table of contents 1 About this manual...............................................

More information

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B 3 136 Synco 700 Extension odules for heating controller RH760B RZ782B RZ783B Extension modules for use with the RH760B heating controller to provide additional auxiliary functions Use Heating plants controlled

More information

7-day room temperature controller

7-day room temperature controller s 2 208 7-day room temperature controller Heating applications REV34.. Mains-independent, battery-operated room temperature controller featuring user-friendly operation, easy-to-read display and large

More information

Product and functional description

Product and functional description Product and functional description Connection example The universal dimmer main module N 528/31 is an installation device for DIN-rail mounting, with N-system dimensions. It is designed for lighting control,

More information

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x 1. Description The supply module was developed specially for direct mounting in hazardous areas in Zone 1 and 21 and is ATEX-certified. The supply module is a permanently installed piece of electrical

More information

Operating instructions Evaluation system for flow sensors VS / / 2013

Operating instructions Evaluation system for flow sensors VS / / 2013 Operating instructions Evaluation system for flow sensors VS3000 7097 / 0 07 / 203 Contents Preliminary note...2 2 Safety instructions...3 3 Function and features... Mounting.... Mounting of the sensors...

More information

Lucid arena pro LED luminaire

Lucid arena pro LED luminaire Operation, installation and service instructions Lucid arena pro LED luminaire Please read these instructions before installing the luminaires, using them for the first time, storage or handling. These

More information

SOLARIMMERSION IV Advanced Installation Manual v1.9

SOLARIMMERSION IV Advanced Installation Manual v1.9 SOLARIMMERSION IV Advanced Installation Manual v1.9 1 Contents 1. Overview 2. Technical Specifications 3. Installation Mounting Electrical Installation Clamp Installation Wiring Diagrams 4. Installation

More information

Heating Circuit Controller

Heating Circuit Controller 2 705 Synco 900 Heating Circuit Controller RRV912 RF-controlled heating circuit controller for up to 2 heating circuits RF communication based on KNX standard (868 MHz, bidirectional) Connection facility

More information

Installation manual plugs and connectors with screw connection (16/32 A)

Installation manual plugs and connectors with screw connection (16/32 A) EN Installation manual plugs and connectors with screw connection (16/32 60003213 Issue 04.2016 2016-04-01 Table of contents 1 About this manual 3 1.1 Structure of the warnings 3 1.2 Symbols used 4 1.3

More information

C9900-P223 and C9900-P224

C9900-P223 and C9900-P224 Installation and Operating instructions for C9900-P223 and C9900-P224 Power Supply Units Version: 1.2 Date: 2012-02-22 Table of contents Table of contents 1. Foreword 2 Notes on the Documentation 2 Liability

More information

User Manual. Item no.: Otto Graf GmbH Carl-Zeiss-Str. 2-6 Tel.: +49(0) Kunststofferzeugnisse D Teningen Fax: +49(0)

User Manual. Item no.: Otto Graf GmbH Carl-Zeiss-Str. 2-6 Tel.: +49(0) Kunststofferzeugnisse D Teningen Fax: +49(0) User Manual AquaControl + Rainwater System Controller Item no.: 351027 Otto Graf GmbH Carl-Zeiss-Str. 2-6 Tel.: +49(0)7641-5890 Kunststofferzeugnisse D-79 331 Teningen Fax: +49(0)7641-58950 Page 1 Figure

More information

MDM 011-Z1 Regen Resistor

MDM 011-Z1 Regen Resistor MDM 011-Z1 Regen Resistor Date of creation: 10.04.2017 Version date: 10.04.2017 Article number: 09-402-011-Z1-E Publisher: SIGMATEK GmbH & Co KG A-5112 Lamprechtshausen Tel.: 06274/4321 Fax: 06274/4321-18

More information

PRO-1250D CT MID DIN rail three phase four wire energy meter.

PRO-1250D CT MID DIN rail three phase four wire energy meter. PRO-1250D CT MID DIN rail three phase four wire energy meter. 1.1 Safety instructions 1.2 Foreword 1.3 MID certificate 1.4 Performance criteria 1.5 Specifications 1.6 Basic errors 1.7 Description 1.8 Dimensions

More information

Digital Room Thermostat

Digital Room Thermostat Salus RT500 Manual 002:89 23/11/10 11:06 Page 1 Digital Room Thermostat Instruction Manual Model No RT500 2 Salus RT500 Manual 002:89 23/11/10 11:06 Page 2 PRODUCT COMPLIANCE This product complies with

More information

Operating instructions Safe AS-i input module ASIM-C-M About this document. Content

Operating instructions Safe AS-i input module ASIM-C-M About this document. Content 7 Set-up and maintenance 7.1 Functional testing....10 7.2 Maintenance...10 EN Operating instructions.............pages 1 to 6 Original 8 Disassembly and disposal 8.1 Disassembly....10 8.2 Disposal...10

More information

Assembly and operating instructions DULCOMARIN II, N-Module (Power Supply Module without Relay) DXMaN

Assembly and operating instructions DULCOMARIN II, N-Module (Power Supply Module without Relay) DXMaN Assembly and operating instructions DULCOMARIN II, N-Module (Power Supply Module without Relay) DXMaN Please enter the identity code of your device here! DXMa _ Please carefully read these operating instructions

More information

Heating Circuit Controller

Heating Circuit Controller 2 706 Synco living Heating Circuit Controller RRV918 RF-controlled heating circuit controller for up to 8 heating circuits RF communication based on KNX standard (868 MHz, bidirectional) Connection facility

More information

English. Operating Manual. Conductive point level switch MLR120. Retain for later reference. Companies / brands of GHM

English. Operating Manual. Conductive point level switch MLR120.  Retain for later reference. Companies / brands of GHM English Operating Manual Conductive point level switch MLR120 Companies / brands of GHM www.ghm-group.de Retain for later reference Table of contents Page 1. Proper use (application areas)... 3 Safety

More information

EWCH 485 Electronic Pulse Counter

EWCH 485 Electronic Pulse Counter Electronic Pulse Counter Technical Data Sheet INSTRUMENT DESCRIPTION GENERAL DESCRIPTION is a programmable microprocessor based counter with 1or 2 outputs. The instrument offers the possibility to program:

More information

SKIVING MACHINE MAINTENANCE & INSTRUCTIONS MANUAL ASSK2. Allswage UK. Roebuck Street, West Bromwich, B70 6RB

SKIVING MACHINE MAINTENANCE & INSTRUCTIONS MANUAL ASSK2. Allswage UK. Roebuck Street, West Bromwich, B70 6RB SKIVING MACHINE ASSK2 MAINTENANCE & INSTRUCTIONS MANUAL A. WARRANTY AND RESPONSIBILITY Warranty: It's the supplier's responsibility to guarantee the conformity of the product, assuring that it's manufactured

More information

COMPACT LED DRIVERS. EasyLine Simple Fix. EasyLine SIMPLE FIX , , , , , , , , ,

COMPACT LED DRIVERS. EasyLine Simple Fix. EasyLine SIMPLE FIX , , , , , , , , , COMPACT LED DRIVERS EasyLine SIMPLE FIX 186719, 186720, 186721, 186722, 186723, 186724, 186725, 186726, 186727, 186728 Typical Applications Built-in in compact luminaires Shop lighting Downlights EasyLine

More information

Product and functional description

Product and functional description Product and functional description The RS 525/23 Universal Dimmer is a KNX device with one dimmer output. The device is installed in an AP 118 Control Module Box or an AP 641 Room Control Box. The bus

More information

Temperature differential controller 5 inputs, 1 output

Temperature differential controller 5 inputs, 1 output emperature differential controller 5 inputs, 1 output Installation and operating instructions EN 741.011 Z02 12.18 Subject to change due to technical improvements! Contents 1 General safety instructions

More information

Demonstration Case BENNING DB 1

Demonstration Case BENNING DB 1 Operating manual Demonstration Case BENNING DB 1 part no. 044132 Table of contents 1 Introduction...3 2 Safety instructions...4 3 Applicable regulations...5 4 Device description...5 4.1 Measuring / testing...

More information

V /06/ Velleman nv

V /06/ Velleman nv DC LAB POWER SUPPLY WITH DUAL LED DISPLAY DC-LABVOEDING - DUBBELE LED-DISPLAY ALIMENTATION DE LABORATOIRE DC À DOUBLE AFFICHEUR LED ALIMENTACIÓN DC PARA LABORATORIO CON DOBLE DISPLAY LED DC-LABORNETZGERÄT

More information

C9900-P208 and C9900-P209

C9900-P208 and C9900-P209 Installation and Operating instructions for C9900-P208 and C9900-P209 Power Supply Units Version: 1.5 Date: 2012-02-22 Table of contents Table of contents 1. Foreword 2 Notes on the Documentation 2 Liability

More information

Electromotoric actuators Torques up to 60 Nm Running times ¹) s. ¹) Predefined by the basic unit (LMV5...)

Electromotoric actuators Torques up to 60 Nm Running times ¹) s. ¹) Predefined by the basic unit (LMV5...) 7 818 Actuators SQM9... Electromotoric actuators Torques up to 60 Nm Running times ¹) 30...120 s ¹) Predefined by the basic unit (LMV5...) The SQM9... and this Data Sheet are intended for use by OEMs which

More information

IGLOO IGLOO EASY INSTRUCTION MANUAL

IGLOO IGLOO EASY INSTRUCTION MANUAL ENGLISH EASY C695 C698 INSTRUCTION MANUAL PRELIMINARY Congratulations on choosing a Clay Paky product! We thank you for your custom. Please note that this product, as all the others in the rich Clay Paky

More information

Product and functional description

Product and functional description Product and functional description Connection example The universal dimmer submodule N 528/41 is an installation device for DIN-rail mounting, with N-system dimensions. It is designed for lighting control,

More information

Operating Manual -ENGLISH- Page 1 KWG-ISO

Operating Manual -ENGLISH- Page 1 KWG-ISO Page 1 KWG-ISO Operating manual English- Status May 2013 Page 2 Manufacturer address KW-Generator GmbH & Co.KG Bänglesäcker 24 73527 Schwäbisch-Gmünd / Lindach Phone: +49 (0) 7171 104 17 0 Fax: +49 (0)

More information

PRO1250D CT MID DIN rail three phase four wire energy meter. User manual Version 1.5

PRO1250D CT MID DIN rail three phase four wire energy meter. User manual Version 1.5 PRO1250D CT MID DIN rail three phase four wire energy meter. User manual Version 1.5 1 Safety instructions...3 2 Foreword...4 3 CE certificates...5 4 MID certificate...7 5 Performance criteria...8 6 Specifications...8

More information

7-day room temperature controller

7-day room temperature controller s 2 205 7-day room temperature controller Heating or cooling applications REV24.. Mains-independent, battery-operated room temperature controller featuring user-friendly operation, easy-to-read display

More information

Room Temperature Controller

Room Temperature Controller 3 023 Room Temperature Controller for four-pipe fan coil units RCC30 Outputs for on / off valve actuators Outputs for three-speed fan Control depending on room or return air temperature Operating modes:

More information

Original operating instructions Fail-safe inductive sensor GF711S / / 2013

Original operating instructions Fail-safe inductive sensor GF711S / / 2013 Original operating instructions Fail-safe inductive sensor GF7S 8528 / 5 / 23 Contents Preliminary note...3. Explanation of symbols...3 2 Safety instructions...4 2. Safety-related requirements regarding

More information

Product Information. DCM Standard indoor stations TK IS A 514 A.. TK IS A 514 AD.. (Design)

Product Information. DCM Standard indoor stations TK IS A 514 A.. TK IS A 514 AD.. (Design) Product Information DCM Standard indoor stations TK IS A 514 A.. TK IS A 514 AD.. (Design) ALBRECHT JUNG GMBH & CO. KG Volmestraße 1 58579 Schalksmühle Phone +49.2355.806-0 Fax +49.2355.806-189 E-Mail:

More information

IGLOO IGLOO EASY INSTRUCTION MANUAL

IGLOO IGLOO EASY INSTRUCTION MANUAL ENGLISH EASY C695 C698 INSTRUCTION MANUAL PRELIMINARY Congratulations on choosing a Clay Paky product! We thank you for your custom. Please note that this product, as all the others in the rich Clay Paky

More information

MC 11 EB-2 Power supply cabinet with external bus, AC version

MC 11 EB-2 Power supply cabinet with external bus, AC version MC 11 EB-2 Power supply cabinet with external bus, AC version USER/MAINTENANCE MANUAL 1 SLOT 0 SLOT 1 SLOT 2 SLOT 3 SLOT 4 SLOT 5 SLOT 6 SLOT 7 SLOT 8 SLOT 9 SLOT 10 SLOT 11 EB-2 (a) MC11 (b) (c) Figures

More information

LINEAR LED DRIVERS. EasyLine Simple Fix. EasyLine SIMPLE FIX , , , , ,

LINEAR LED DRIVERS. EasyLine Simple Fix. EasyLine SIMPLE FIX , , , , , LINEAR LED DRIVERS EasyLine SIMPLE FIX 186712, 186713, 186714, 186715, 186716, 186760 Typical Applications Built-in in linear luminaires for Office lighting Weatherproof Luminaires EasyLine Simple Fix

More information

QXA2000 QXA2001. Condensation Monitor QXA2001 QXA2000 AQX2000

QXA2000 QXA2001. Condensation Monitor QXA2001 QXA2000 AQX2000 1 542 1542P03 1542P01 1542P02 QXA2001 QXA2000 AQX2000 Condensation Monitor QXA2000 QXA2001 The QXA2000 condensation monitor is used to avoid damage due to condensation on chilled ceilings and in HVAC plant.

More information

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING Product and Applications Description Note If the application program is not loaded completely by the ETS, you had better interrupt the 24 V voltage supply of the I/O-module during the loading interval.

More information

Universal Modules. Synco 700. Extension modules for use with controls of the Synco 700 family. Use

Universal Modules. Synco 700. Extension modules for use with controls of the Synco 700 family. Use s 3 146 Synco 700 Universal Modules RMZ78 Extension modules for use with controls of the Synco 700 family. Use For heating, ventilation, air conditioning and chilled water plant equipped with controls

More information

Documentation. GEM 3KW Power Module. Installation Manual. Revision 3 December 2104

Documentation. GEM 3KW Power Module. Installation Manual. Revision 3 December 2104 Documentation GEM 3KW Power Module Installation Manual Revision 3 December 2104 Apollo Solar Electric Limited Burnt Thorns Kilsby Lane Rugby CV21 4PN Tel: +44 (0) 1788 511055 Fax: +44 (0) 1788 511078 service@apollosolarelectric.co.uk

More information

User Manual. 2.2KW/7.5KW/11KW Solar Inverter for Water Pump. Version: 1.8

User Manual. 2.2KW/7.5KW/11KW Solar Inverter for Water Pump. Version: 1.8 User Manual 2.2KW/7.5KW/11KW Solar Inverter for Water Pump Version: 1.8 Table Of Contents ABOUT THIS MANUAL... 1 Purpose... 1 Scope... 1 SAFETY INSTRUCTIONS... 1 Inspection... 1 Installation... 1 Operation...

More information

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005 Product and Applications Description Application Programs The application programs of the dimmer UP 525/01 consist of two elements: the actuating and the sensor program element. The tasks actuating program

More information

AV24-MFT AV24-MFT2 AV24-MFT2-C105. Power consumption In operation For wire sizing N 1700 N Control Control signal Y Operating range

AV24-MFT AV24-MFT2 AV24-MFT2-C105. Power consumption In operation For wire sizing N 1700 N Control Control signal Y Operating range echnical data sheet AV4-MF()(-C105) Multi-functional linear actuators for -way and 3-way globe valves Actuating force 500 N Nominal voltage AC/DC 4 V Control: modulating DC 0 10 V Position feedback DC

More information

CU USB-Extender-Rx (USB and DVI Extender) Version: 0.3 Date:

CU USB-Extender-Rx (USB and DVI Extender) Version: 0.3 Date: CU8860-0000 USB-Extender-Rx (USB and DVI Extender) Version: 0.3 Date: 2006-02-20 Table of Contents Table of Contents 1 Foreword 1 1.1 Notes on the documentation 1 1.1.1 Liability Conditions 1 1.1.2 Conditions

More information

RXB39.1. Room controller RXB. Communicating room controller for fan-coil applications FC-13

RXB39.1. Room controller RXB. Communicating room controller for fan-coil applications FC-13 s 3 875 RXB Room controller Communicating room controller for fan-coil applications FC-13 RXB39.1 The RXB39.1 room controller is used for temperature control in individual rooms. For 2-pipe or 4-pipe fan-coil

More information

Display And Operating Unit

Display And Operating Unit DCU 001 DCU 100 DCU 150 DCU 200 DCU 300 DCU 600 Display And Operating Unit PM 800 477 BE/G (0601) Index Page 1. Safety Instructions... 3 2. Understanding The Control And Operating Unit DCU... 4 2.1. For

More information

Extension module for lighting control

Extension module for lighting control s 3 842 DESIGO RXC Extension module for lighting control Extension to the RXC30 / RXC31 / RXC38 room controller RXC40.1 RXC40.5 The RXC40 extension module is used in conjunction with an RXC30, RXC31 or

More information