Quick Connectors for PROFIBUS SUBCON-PLUS-PROFIB/...
|
|
- Kory Rice
- 6 years ago
- Views:
Transcription
1 Quick Connectors for PROFIBUS SUBC-PLUS-PROFIB/.... Description The new SUBC-PLUS-PROFIB/... SUB-D series has been specifically designed for use in PROFIBUS systems up to 2 Mbps. It enables convenient and quick connection of the incoming and outgoing bus cable under field conditions. The range consists of six quick connectors - the right solution for every PROFIBUS application: Angled or straight cable feed With or without programming interface Connection using spring-cage or screw-cage terminal blocks The use of connectors with spring-cage terminal blocks is preferred for PROFIBUS cables with solid copper wires. Connectors with screw-cage terminal blocks (.../SC) are designed for cables with stranded copper wires. The terminal resistor is already integrated in all versions and can be enabled externally using a slide. The outgoing bus segment is disabled simultaneously. This makes it easier to start up segment by segment and prevents incorrect termination. In addition to this, the high-quality shielded connector housing also ensures high immunity to interference even with maximum transmission rates. A special feature of the angled connector version is that the internal connection unit can be reversed. This enables you to decide locally whether the cable is to be fed from the right or the left. If it is not possible to use the angled version, the SUBC-PLUS.../AX compact connector with a straight cable feed is also available. The connectors are designed for all standard PROFIBUS cables with an outside diameter of 8 mm (0.35 in.) (type A and B). If a Fast Connect cable is used, installation effort is reduced to a minimum using the PSM-STRIP-FC/PROFIB quick stripping tool: Strip the cable and individual wires Insert them in the connector Close the housing cover Should you have any technical questions, please contact us: PSM HOTLINE: FAX: interface-service@phoenixcontact.com Headquarters: Phoenix Contact GmbH & Co. KG Flachsmarktstraße Blomberg Germany Phone Fax Local contact:
2 * 0 49,5 44,5 Quick Connectors for PROFIBUS SUBC-PLUS SUBC-PLUS-PROFIB/(AX/) Technical Data Function block diagram 6 VP 2B 390Ω 220Ω 390Ω 5 GND 2A S B 3 D(P) A 8 D(N) SUBC-PLUS-PROFIB/ connectors for PROFIBUS up to 2 Mbps with angled cable output Description PROFIBUS connector up to 2 Mbps, angled version, integrated resistor, which can be enabled externally Spring-cage connection Screw-cage connection Type SUBC-PLUS-PROFIB SUBC-PLUS-PROFIB/SC Order No Pcs. Pkt. PROFIBUS connector up to 2 Mbps, as above, however also with a PG-SUB-D female connector for the connection of a programming device Quick stripping tool, for PROFIBUS Fast Connect cable Stripping pliers PROFIBUS Fast Connect cable Spring-cage connection Screw-cage connection SUBC-PLUS-PROFIB/PG SUBC-PLUS-PROFIB/PG/SC PSM-STRIP-FC/PROFIB QUICK-WIREFOX 6 PSM-CABLE-PROFIB/FC Technical Data Connector Programming connection Cable feed Conductor cross-section Spring-cage terminal blocks (solid/awg) Screw-cage terminal blocks (solid/stranded/awg) Connector cycles Cable diameter (maximum/minimum) Temperature range Degree of protection Housing material Pin assignment Terminal resistance 9-pos. D-SUB male connector 9-pos. D-SUB female connector Left or right mm 2 /28-20 AWG mm 2 /0.4- mm 2 /26-6 AWG > mm (0.35 in.) (±0.4 mm [0.06 in.]) -20 C to +75 C (-4 F to 67 F) IP 40 ABS, metal-plated 3.8/on 2 terminals each (see description) 220 Ω/390 Ω, resistor can be enabled externally Dimensional diagram Mounting screw Upper housing shell 60 6 PG female connector Connection block A B 2A 2B 35 * Connector with PG-SUB-D female connector for connecting a programming device Figure 05 Strain relief Lower housing shell Figure 06 PHOENIX CTACT page 2 of 6
3 58,2 Quick Connectors for PROFIBUS SUBC-PLUS SUBC-PLUS-PROFIB/(AX/)... Function block diagram 6 VP 2B 390Ω 220Ω 390Ω 5 GND 2A S B 3 D(P) A 8 D(N) SUBC-PLUS-PROFIB/AX/ connectors for PROFIBUS up to 2 Mbps with straight cable output Description PROFIBUS connector up to 2 Mbps, straight version, integrated resistor, which can be enabled externally Spring-cage connection Type SUBC-PLUS-PROFIB/AX SUBC-PLUS-PROFIB/AX/SC Order No Pcs. Pkt. Quick stripping tool, for PROFIBUS Fast Connect cable Stripping pliers PROFIBUS Fast Connect cable PSM-STRIP-FC/PROFIB QUICK-WIREFOX 6 PSM-CABLE-PROFIB/FC Technical Data Connector Cable feed Conductor cross-section Connector cycles Cable diameter (maximum/minimum) Temperature range Degree of protection Housing material Pin assignment Terminal resistance Spring-cage terminal blocks (rigid/awg) Screw-cage terminal blocks (rigid/flexible/awg) 9-pos. D-SUB male connector Straight mm 2 /28-20 AWG mm 2 /0.4- mm 2 /26-6 AWG > mm (0.35 in.) (±0.4 mm [0.06 in.]) -20 C to +75 C (-4 F to 67 F) IP 40 ABS, metal-plated 3.8/on 2 terminals each (see description) 220 Ω/390 Ω, resistor can be enabled externally Dimensional diagram Mounting screw 20 7 Upper housing shell Strain relief SUBC-PLUS-PROFIB/AX Connection block Release rocker 3,5 Lower housing shell Figure 07 Figure 08 PHOENIX CTACT page 3 of 6
4 Quick Connectors for PROFIBUS SUBC-PLUS SUBC-PLUS-PROFIB/(AX/) Connection Notes The following stripping tools can be used for quick and convenient stripping (Figure 09): PSM-STRIP-FC/PROFIB (Order No.: ) and QUICK-WIREFOX 6 (Order No.: ). Stripping Lengths Observe the recommended stripping lengths given in the diagrams Figure Spring-Cage Connection SUBC PLUS PROFIB/(PG) Push the stripped wires into the corresponding contacts of the connection block. The wires establish contact automatically when inserted. To release the connection, press the orange release rocker. The strain relief and the shield contact for the bus cable are established when the upper housing shell is mounted. A B 2A 2B Cable Feed The SUBC-PLUS-PROFIB connector without PG connection provides the option of a cable feed on the left or right-hand side. Upon delivery the connector is assembled for left-hand feed (Figure 0). The cable feed cannot be reversed for the SUBC-PLUS-PROFIB/ PG Figure 0 Mounting the SUB-D Connector for Right-Hand Side Cable Feed If right-hand cable feed is required, remove the printed circuit board using a screwdriver by prying it out of the lower housing shell in the area of the fixing rivets. Fig. a A B 2A 2B Figure Finally remove the connection block from the printed circuit board in accordance with Figure /2 and turn it 80. 2B 2A B A A B 2A 2B Fig. b 2B 2A B A Fig. 2c Fig. 2d Figure 2 Insert the printed circuit board in the upper housing shell and connect the bus cables (Figure 3). 2B 2A B A mm Figure 3 PHOENIX CTACT page 4 of 6
5 Quick Connectors for PROFIBUS SUBC-PLUS SUBC-PLUS-PROFIB/(AX/) Screw-Cage Terminal Block Connection SUBC-PLUS-PROFIB/(PG/)SC Screw the stripped wires into the corresponding contacts of the connection block. The strain relief for the bus cable is established when the upper shell is mounted. Cable Feed The SUBC-PLUS-PROFIB/ SC connector without PG connection provides the option of a cable feed on the left or right-hand side. Upon delivery the connector is assembled for left-hand feed (Fig. 5). The cable feed cannot be reversed for the SUBC-PLUS-PROFIB/ SC A B 2A 2B 2B 2A B A Figure 4 SUBC-PLUS-PROFIB/SC Mounting the SUB-D Connector for Right-Hand Side Cable Feed If right-hand cable feed is required, remove the printed circuit board using a screwdriver by prying it out of the lower housing shell in the area of the fixing rivets. Insert the printed circuit board in the upper housing shell and connect the bus cables (Fig. 6). A B 2A 2B 2B 2A B A mm SUBC-PLUS-PROFIB/PG/SC mm Figure Spring-Cage Connection SUBC-PLUS-PROFIB/AX Stripping Lengths Observe the recommended stripping lengths (Fig. 6). Connection Push the stripped wires into the corresponding contacts of the connection block. The wires establish contact automatically when inserted. To release the connection, press the orange release rocker mm Figure Screw-Cage Terminal Block Connection SUBC-PLUS-PROFIB/AX/SC Connection Screw the stripped wires into the corresponding contacts of the connection block. B A B A mm Figure 7 PHOENIX CTACT page 5 of 6
6 Quick Connectors for PROFIBUS SUBC-PLUS SUBC-PLUS-PROFIB/(AX/) Bus Terminal Resistors Activating the terminal resistor and disconnecting the outgoing bus cables: The terminal resistors are activated at the start and end of the bus system using the slide (Figure 08). The connection terminals (2A/2B) for the outgoing bus cable are disconnected simultaneously. The terminal resistor must be deactivated on all other nodes of the bus system. Start End Connecting the Bus Cables Always connect the incoming bus cable to terminal connections A/B (even at the start of the bus system). Always connect the outgoing bus cable to terminal connections 2A/2B. Figure 8 PHOENIX CTACT September 5, 200 TNR: PHOENIX CTACT page 6 of 6
PHOENIX CONTACT
Fast connection connector for PROFIBUS systems Data sheet 101610_en_07 PHOENIX CTACT 2011-11-17 1 Description The D-SUB series SUBC-PLUS-PROFIB is specially designed for use in PROFIBUS systems up to 12
More informationSUBCON-PLUS-PROFIB...
Fast connector for PROFIBUS systems Data sheet 101610_en_10 PHOENIX CONTACT 2017-03-27 1 Description The SUBCON-PLUS-PROFIB... D-SUB series is specifically designed for use in PROFIBUS systems up to 12
More informationPHOENIX CONTACT Pin. SUBCON-PLUS M ARCNET, MULTI/MININET (B&R), SYSTEM 2003 (B&R), P-NET SUCONET K1, K2 (EATON/Moeller),
Fast connector with screw terminal block connection for fieldbus systems Data sheet 00287_en_02 PHOENIX CONTACT 207-04-2 Description The SUBCON-PLUS/... D-SUB series is specifically designed for use in
More informationPSI-MODEM-SHDSL/PB. Broadband PROFIBUS extender, SHDSL PROFIBUS leased line modem. Data sheet _en_03. 1 Description. 1.
PSI-MODEM-/PB Broadband PROFIBUS extender, PROFIBUS leased line modem Data sheet 104396_en_03 1 Description PHOENIX CONTACT 2013-08-21 1.1 Features The PROFIBUS extender can be used to easily network PROFIBUS
More informationFactory Line Accessories FL PLUG RJ FL CRIMPTOOL
Factory Line Accessories FL PLUG RJ... FL CRIMPTOOL. Description FL PLUG RJ connectors and the corresponding FL CRIMPTOOL crimping pliers are available for field terminations of RJ connectors. The shielded
More informationExtract from the online catalog
Please note that the data given here has been taken from the online catalog. For comprehensive information and data, please refer to the user documentation at http://www.download.phoenixcontact.com. The
More informationPSI-MOS-PROFIB/FO 850 T
Extract from the online catalog PSI-MOS-PROFIB/FO 850 T Order No.: 2708261 FO converter with integrated optical diagnosis, alarm contact, for PROFIBUS up to 12 MBit/s, T-coupler with two FO interfaces
More informationM12 Field Wireable Connectors. M12 CAT.6A Field Wireable Connectors. M12 Field Wireable Connectors for PROFINET
M12 Connectors Application Advantage Shielded design ETHERLINE Ethernet Cable, Connectors & Tools M12 Field Wireable Connectors Male Female Temperature Range: Max. 85 C Nominal Voltage: Nominal Current:
More informationPHOENIX CONTACT - 11/2007. This data sheet is only valid in association with the IB IL SYS PRO UM E user manual.
INTERBUS Inline Bus Coupler; Remote Bus Connections Via D-SUB Connectors REMOTE IN BA UL RD RC DSUB LD AUTOMATIONWORX Data Sheet 6362_en_03 PHOENIX CONTACT - 11/2007 REMOTE OUT Description The bus coupler
More informationVARIOSUB D-SUB 25 Contact Inserts, Sleeve Housings
Contact Inserts, Sleeve Housings Introduction VARIOSUB is a range of plug connectors specially designed for signal and data technology in an industrial environment with high degrees of protection, temperatures
More informationBus Connector for PROFIBUS, 90
Catalog 09 PROFIBUS 31 Bus Connector for PROFIBUS, 90 Integrated terminating-resistor 90 cable-outlet Small housing with (l.) and without (r.) prog. device connector The compact design of the bus connectors
More informationLED CONNECTION TECHNOLOGY. For LED Modules and Lighting
LED CONNECTION TECHNOLOGY For LED Modules and Lighting LIGHTING TECHNOLOGY BY WAGO Highlights in Connection Technology Today, modern lighting technology bridges the gap between well-being, economical operation
More informationTechnical data: Pin Spacing
282 Female Connectors, Double-Row Pin Spacing: 3.5 mm Universal connection for all conductor types Unique, compact, double-row connector system for conductor cross sections up to 1.5 mm 2 High-density,
More informationFLM DI 8 M12. Function. Fieldline Modular Device With Eight Digital Inputs. Data Sheet
Fieldline Modular Device With Eight Digital Inputs Data Sheet 697000 02/2004 This data sheet is only valid in association with the FLS FLM SYS INST UM E user manual or the user manual for your bus system
More information11 PROFIBUS Fieldbus Connector
750-960 PROFIBUS Fieldbus Connector 634 54 mm> < < 45mm 5 < 36,7mm < 372 mm < 54 mm < 36 mm / 42 in < 5-6 mm / 022 in < 0 mm / 0394 in The fieldbus connector links a PROFIBUS device
More informationIDC Field Wireable eurofast & picofast Connectors
Advanced Connection Solutions for Manufacturers Worldwide! IDC Field Wireable eurofast & picofast Connectors picofast Field Wireable IDC Connector eurofast Field Wireable IDC Connector Overview Connection
More informationonlinecomponents.com
VARIOSUB RJ4/IP0 Plug Connectors VARIOSUB-RJ4/IP0 was developed for using RJ4 plug connectors in harsh industrial environments. With it, devices for Industrial Ethernet can also utilize the standard plug
More informationPROFIBUS Fieldbus Connector 634
750-960 PROFIBUS Fieldbus Connector 634 54 mm> < < 45mm < 36,7mm < 372 mm < 54 mm < 36 mm / 142 in < 5-6 mm / 022 in < 10 mm / 0394 in The fieldbus connector links a PROFIBUS
More informationILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description
Inline Block IO Module for PROFIBUS With 32 Digital Outputs AUTOMATIONWORX Data Sheet 6889_en_04 Description PHOENIX CONTACT - 03/2007 & & ' ) The ILB PB 24 DO32 module is designed for use within a PROFIBUS
More informationPSM-ME-RS232/TTY-P Interface converter for RS-232 to TTY transmission systems
Interface converter for RS- to transmission systems. Short Description The rail-mountable and compact interface converters have been designed especially for industrial use in the switch cabinet or switch
More informationItem No.: /
mounting adapter also for DIN 35 rail; % protected against mismating; Plate thickness 06x12 mm; Male connector; with snap-in mounting foot; 4-pole; pin spacing 35 mm / 0138 in; with 209-137 mounting adapter
More informationPAS 300, PROFIBUS Slave Interface Module
Catalog 08 PROFIBUS-Components 27 PAS 300, PROFIBUS Slave Interface Module PROFIBUS PROFIBUS slave interfaces PROFIBUS slave module The PROFIBUS slave interface module PAS 300 from the Systeme Helmholz
More informationMULTI CONNECTION SYSTEM Product Overview
MULTI CONNECTION SYSTEM Product Overview MCS MULTI CONNECTION SYSTEM Product Overview Sorted by Pin Spacing 2.5 mm MICRO* mm, 3.81 mm MINI 100% Mismating Protection mm MINI HD* mm MINI SL screw 714 Series
More informationSystem Cables for Mitsubishi Melsec Q FLK 50/EZ-DR/D37SUB/... CABLE-D37-M2,5/4x14/...
System Cables for Mitsubishi Melsec Q FLK 50/EZ-DR/D37SUB/... CABLE-D37-M2,5/4x4/.... Short Description These system cables are specifically designed for Mitsubishi I/O cards with a male connector. Connecting
More informationMale connector; 6-pole; pin spacing 3.5 mm / in; 100% protected against mismating
Male connector; 6-pole; pin spacing 35 mm / 0138 in; % protected against mismating Item Male connector; 6-pole; pin spacing 35 mm / 0138 in; % protected against mismating Marking Business data Supplier
More informationRedundancy Module QUINT-DIODE/40
Redundancy Module QUT DIODE provides: 00% decoupling of power supplies connected in parallel Can be installed in potentially explosive areas Load currents up to 60 A supported Easy assembly by snapping
More informationPHOENIX CONTACT - 07/2006
Buffer module with maintenance-free capacitor-based power storage device INTERFACE Data sheet 102035_03_en PHOENIX CONTACT - 07/2006 Description Short-term mains interruptions are bridged by QUINT BUFFER,
More informationSUNCLIX Connection technology for photovoltaics
SUNCLIX Connection technology for photovoltaics Connection technology for photovoltaics Are you looking for innovative and reliable connection technology for your PV modules, inverters or the complete
More informationPSR-SCP- 24DC/URM4/4X1/2X2/B PSR-SPP- 24DC/URM4/4X1/2X2/B
Safety Relay as a Contact Extension Block INTERFACE Data Sheet PHOENIX CONTACT - 05/2006 Description The PSR-...- 24DC/URM4/4X1/2X2/B safety relay can be used as a contact extension block in safety circuits
More informationHan-Brid. Contents Han-Brid Features Han-Brid Data interfaces Han-Brid Overview Han-Brid Cu
Contents Page Features... 19.02 Data interfaces... 19.03 Overview... 19.04 Cu... 19.06 F.O.... 19.08 Quintax 3 A... 19.10 RJ45 C... 19.12 USB / FireWire... 19.14 Han 4 A SC... 19.16 Hoods/Housings... 19.18
More informationComplete the Installation SKINTOP MS-SC. Color Code: Approvals: Nominal Outer Diameter
BUS UNITRONIC BUS PB For PROFIBUS-DP/FMS/FIP bus systems; stationary applications; 150 Ω UNITRONIC BUS PB UNITRONIC BUS PB FC UNITRONIC BUS PROFIBUS cables are designed for automation networks requiring
More informationPB IL 24 BK DIO 16/16
PROFIBUS-DP/V1 Bus Coupler Station With 16 Digital Inputs and 16 Digital Outputs Data Sheet 643701 07/2003 $ "! % * This data sheet is only valid in association with the "Configuring and Installing the
More informationMale connector; with fixing flanges; 6-pole; pin spacing 5.08 mm / 0.2 in; for screw or similar mounting types; for parallel or perpendicular mounting
Male connector; with fixing flanges; 6-pole; pin spacing 508 mm / 02 in; for screw or similar mounting types; for parallel or perpendicular mounting Item No: 231-636/019-000 Male connector; with fixing
More informationPSR-SCP- 24DC/SSM/2X1 PSR-SPP- 24DC/SSM/2X1
PSR-SCP- DC/SSM/2X1 PSR-SPP- DC/SSM/2X1 Safety Relay With Downtime Monitoring INTERFACE Data Sheet PHOENIX CONTACT - 05/2006 Description The PSR-...- DC/SSM/2X1 safety relay can be used in safety circuits
More informationonlinecomponents.com
Repeater for RS-485 2-Wire Systems INTERFACE Data Sheet 102964_C01_en 1 Description The PSI-REP-RS485W2 DIN-rail mountable, modular RS-485 repeater is designed to meet the high requirements associated
More informationLED Connection Technology For LED Drivers, Modules and Lights
LED Connection Technology For LED Drivers, Modules and Lights SMD PCB TERMINAL BLOCKS for LED Modules and Drivers 2059 Series For the Smallest Sizes Conductor range: 26 20 AWG (0.14 0.5 mm 2 )*, solid
More informationMINI MCR-SL-CVS NC
Constant voltage source Data sheet 105264_en_01 PHOENIX CONTACT 2013-04-03 1 Description Configurable constant voltage source for generating highprecision constant voltages. The voltage supply is also
More informationRAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description
I/O extension module, eight digital transistor outputs Data sheet 105364_en_00 PHOENIX CONTACT 2013-03-26 1 Description The I/O extension module can be used in conjunction with Radioline wireless modules
More informationThis data sheet is only valid in association with the IL SYS INST UM E user manual.
Inline analog input terminal, 4 inputs for connecting voltage signals Data sheet 8081_en_01_C01 PHOENIX CONTACT 2015-04-14 1 Description The terminal is designed for use within an Inline station. It is
More informationExtract from the online catalog
Please note that the data given here has been taken from the online catalog. For comprehensive information and data, please refer to the user documentation at http://www.download.phoenixcontact.com. The
More informationVersaMax IP Input Module
Module is used to accept digital input signals. Module Specifications Housing dimensions (width x height x depth) Connection style Operating temperature Storage temperature Operating/storage humidity 60mm
More informationExtract from the online catalog
Please note that the data given here has been taken from the online catalog. For comprehensive information and data, please refer to the user documentation at http://www.download.phoenixcontact.com. The
More informationMINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description
Repeater power supply, active Data sheet 09_en_0 PHOENIX CONTACT 0--0 Description The. mm wide... repeater power supply supplies transmitters in the field and electrically isolates the input signal from
More informationMINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description
Configurable signal duplicator Data sheet 102382_en_03 PHOENIX CONTACT 2012-05-02 1 Description The MINI MCR-SL-UI-2I(-SP)(-NC) configurable signal duplicator is used to electrically isolate, condition,
More informationERbic. Bus Interface Connector System Catalog E /06 Edition 4
ERbic Bus Interface Connector System www.erni.com Catalog E 074441 01/06 Edition 4 www.erni.com 1 www.erni.com 2 Katalog Catalog D E 074441 074440 01/06 Ausgabe Edition 4 3 www.erni.com Table of Contents
More information07. har-link Interface Connectors
. Interface Connectors The highest data rates in combination with perfect shielding characterize the connector. This way data can be passed on optimally within the control cabinet. The locking mechanism
More informationMINI MCR-SL-PT100-UI-200
Configurable temperature transducer for PT00 INTERFACE Data sheet 078_en_0 PHOENIX CONTACT 00-0-5 Description The MINI MCR-SL-PT00-UI-00... is a configurable -way isolated temperature transducer. It is
More informationVL BPC 100. Valueline configurable box PC. Data sheet 3063_en_E. 1 Description. 2 Features
Valueline configurable box PC Data sheet 0_en_E Description PHOENIX CONTACT 0-07- Features The VL BPC 000 is a configurable box PC that can be mounted either directly on a wall or on a DIN rail. The VL
More informationonlinecomponents.com
Converter for RS-422/485 4-Wire/INTERBUS PSI-MOS-RS422/... This data sheet applies to the following items: PSI-MOS-RS422/ 660 E Order No. 27 08 34 2 PSI-MOS-RS422/ 660 T Order No. 27 08 38 4 PSI-MOS-RS422/
More informationMINI MCR-SL-UI-2I(-SP)(-NC)
Data Sheet 03/2005 Product Description Features Configurable signal duplicator MINI MCR-SL-UI-2I(-SP)(-NC) is used to electrically isolate, condition, amplify, and filter analog standard signals. On the
More informationAccessories Bus Terminals
Accessories s Connectors Lightbus Z1000 Z1010 Z1020 standard connector for 1,000 µm plastic fibre standard connector for 200 µm PCS fibre coupling for Z1000 PROFIBUS ZB3100 ZB3101 ZB3102 ZS1031-3000 ZS1031-3500
More informationMINI MCR-SL-PT100-UI(-SP)(-NC)
Configurable Temperature Transducer for PT100 Data Sheet 04/2005 Functions MINI MCR-SL-PT100-UI(-SP)(-NC) is a configurable 3-way isolated temperature measuring transducer. It is suitable for the connection
More informationRAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description
I/O extension module with 8 digital inputs or 2 pulse inputs INTERFACE Data sheet 0483_en_00 PHOENIX CONTACT 203-04-05 Description The I/O extension module can be used in conjunction with Radioline wireless
More informationPHOENIX CONTACT - 05/2007
Ex Universal Module Carrier (Motherboard) for Accommodating 3-Wire Measuring Transducers, Intrinsically Safe, for a Maximum of 8 PI Ex Modules INTERFACE Data Sheet 103030_00_en PHOENIX CONTACT - 05/2007
More informationHan PCB termination. Han-Fast Lock PCB adapter for Han DD PCB adapter for Han DDD module
Han termination Contents Page Han-Fast Lock... 20.11 adapter for Han DD... 20.13 adapter for Han DDD module... 20.16 adapter for Han 40 A Axial module... 20.18 adapter for Han E... 20.20 adapter for Han
More informationTOPJOB S Sensor/Actuator Terminal Blocks Pluggable Signal Level with Push-in CAGE CLAMP Reliability
TOPJOB S Sensor/Actuator Terminal Blocks Pluggable Signal Level with Push-in CAGE CLAMP Reliability TOPJOB S SEND THE RIGHT SIGNALS For the very first time, sensor/actuator wiring is pluggable between
More information7XV5103 RS485 Bus Systems up to 115 kbit/s (not suitable for PROFIBUS)
7XV5103 RS485 Bus Systems up to 115 kbit/s (not suitable for PROFIBUS) LSP2895.tif LSP2396-afp.tif RS485 bus cable system Fig. /2 7XV5103 cable and connector modules/adapters Description The RS485 bus
More informationILBIB24DO16-DSUB. Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors
Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors AUTOMATIONWORX Data Sheet 7119_en_02 PHOENIX CONTACT - 03/2007 Description The ILB IB 24 DO16-DSUB module
More information07. har-link INTERFACE CONNECTORS
. INTERFACE CONNECTORS The highest data rates in combination with perfect shielding characterize the connector. This way data can be passed on optimally within the control cabinet. The locking mechanism
More informationFL MC 2000E (SM40) LC
IEC 61850 fiber optic converter with LC fiber optic connection (1310 nm) to convert 100Base-Tx to single- or multi-mode fiber glass Data sheet 3205_en_C 1 Description PHOENIX CONTACT 2014-04-04 2 Features
More informationMINI MCR-SL-MUX-V8-FLK 16
Multiplexer Data sheet 445_en_4 PHOENIX CONTACT 22-5-2 Description The MINI Analog multiplexer can be used to generate one analog output from up to eight input signals. During cyclical execution, 8, 6,
More informationFACTORY AUTOMATION QUICK START GUIDE IC-KP-*
FACTORY AUTOMATION QUICK START GUIDE IC-KP-* IDENTControl units With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery for Products
More informationFemale connector; 2-pole; pin spacing 5 mm / in; codable; only 1 locking latch; with coding finger; with latch
Female connector; 2-pole; pin spacing 5 mm / 097 in; codable; only locking latch; with coding finger; with latch Item No: 23-02/026-000 Female connector; 2-pole; pin spacing 5 mm / 097 in; codable; only
More informationPowerDRIVE-Box GEL 6505 Interface for controlling up to 5 positioning drives
PowerDRIVE-Box GEL 6505 Interface for controlling up to 5 positioning drives Technical information Version 208-05 GEL 6505A: Box for top hat rail mounting, IP 20 variant General The PowerDRIVE-Box GEL
More informationMINI MCR-SL-PT100-UI. Active resistance thermometer measuring transducer. Data sheet. 1 Description
Active resistance thermometer measuring transducer Data sheet 099_en_06 PHOENIX CONTACT 0-0- Description The 6. mm wide MINI MCR-SL-PT00-UI-... is a configurable, -way isolated temperature measuring transducer.
More informationCLIPLINE complete. The modular terminal block system for all applications
CLIPLINE complete The modular terminal block system for all applications CLIPLINE complete All connection technologies, one system With CLIPLINE complete, the unique modular terminal block system from
More informationIB ST 24 AO 4/EF. INTERBUS-ST analog output module, 4 outputs, 0-10 V, ±10 V, 0-20 ma, 4-20 ma. Data sheet. 1 Description
INTERBUS-ST analog output module, 4 outputs, 0-10 V, ±10 V, 0-20 ma, 4-20 ma Data sheet 105597_en_01 PHOENIX CONTACT 2014-10-24 1 Description The module is designed for use within an ST station. It is
More informationInstaller Connectors Overview Suitable for lighting, power, HVAC & other applications
Installer Connectors Overview Suitable for lighting, power, HVAC & other applications 221 Series Compact Lever Connectors 221 Series - 4mm² 0.2-4mm 2 solid & stranded 0.14-4mm 2 fine-stranded 450 V/4 kv/2
More informationTOPJOB S Sensor/Actuator Terminal Blocks with Push-in CAGE CLAMP Reliability
TOPJOB S Sensor/Actuator Terminal Blocks with Push-in CAGE CLAMP Reliability TOPJOB S SEND THE RIGHT SIGNALS. TOPJOB S Sensor/Actuator Terminal Blocks with Push-in CAGE CLAMP Reliability TWO IN ONE. WITH
More informationUser Manual HMI Linkbox HL01 DP/MPI
User Manual HMI Linkbox HL01 DP/MPI Part Number: 80860.603 Version: 1 Date: 07.05.2005 Valid for: HL01 DP/MPI Version Date Modifications 1 07.05.2005 First edition This manual, including all illustrations
More informationPHOENIX CONTACT Features
Electronic monitoring relay for temperature monitoring Data sheet 107385_en_00 1 Description PHOENIX CONTACT - 2016-05-10 Features Safety and system availability requirements are constantly on the increase
More informationVL BPC MINI. A configurable industrial computer platform. Data sheet 2930_en_F. 1 Description. 2 Features
A configurable industrial computer platform Data sheet 90_en_F Description PHOENIX CONTACT 0-08- Features The VL BPC MINI is an embedded box PC and is part of the Valueline family of industrial computers.
More information07. har-link Interface Connectors
. Interface Connectors The highest data rates in combination with perfect shielding characterize the connector. This way data can be passed on optimally within the control cabinet. The locking mechanism
More informationFL MC 10/100BASE-T/FO-660
Extract from the online catalog FL MC 10/100BASE-T/FO-660 Order No.: 2708193 FO converter, for converting 10/100Base-T to polymer and HCS fiber, (660 nm), SCRJ FO connection (PROFINET standard), rail-mountable,
More informationThrough-Board SMD PCB Terminal Block; 0.75 mm² Pin Spacing: 6.5 mm 2070 Series
Volume, Section SMD PCB Terminal Blocks Through-Board SMD PCB Terminal Block; 0.75 mm² 070 Series SMD PCB terminal blocks with Push-in CAGE CLAMP connection for back-side wiring of LED modules Low profile
More informationValueline Industrial PC
A configurable industrial computer platform AUTOMATION Data Sheet 2643_en_F 1 Description PHOENIX CONTACT 2011-07-15 2 Features The Valueline Industrial PC (VL IPC) product line is a configurable industrial
More informationPHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.
Primary-switched power supply for building automation INTERFACE Data sheet 103505_en_02 1 Description PHOENIX CONTACT - 08/2009 Features STEP POWER power supply units for building automation The new STEP
More informationApplications
Han PCB adapter Contents Page Technical characteristics PCB adapter for Han DD... 20.02 Han DD Inserts with PCB adapter... 20.03 Technical characteristics PCB adapter for Han E... 20.04 Han E Inserts with
More informationVL BPC MINI. A configurable industrial computer platform Intel Atom Z510PT CMAT IPC Module Option [I28] AUTOMATION Data Sheet 2930_en_A.
A configurable industrial computer platform Intel Atom Z0PT CMAT IPC Module Option [I8] AUTOMATION Data Sheet 90_en_A Description PHOENIX CONTACT 0-0-0 Features The VL BPC MINI is an embedded box PC and
More informationBus Interface Connector System Versions for Bitbus, CAN -Bus, Interbus -S (field bus) and Profibus
Bus Interface Connector System Versions for Bitbus, CAN -Bus, Interbus -S (field bus) and Profibus S 48 General The ERbic line of universal bus interface connector systems is versatile, compact and easy
More informationSummary of shell housings and accessories Shell housing A Shell housing D EMC housing
Directory chapter 20 Page Summary of shell and accessories........................... 20.02 housing C.......................... 20.04 housing A................................................. 20.08 housing
More informationItem No.: /
Angled female connector; with snap-in mounting foot; 3-pole; pin spacing 5 mm / 097 in; 00% protected against mismating; for panel mounting; Plate thickness 06x2 mm; Fixing holes 35 mm Ø Item Angled female
More informationSTEP-PS/1AC/24DC/1.75
Primary-switched power supply, 1 AC, output current 1.75 A INTERFACE Data Sheet 103506_en_00 1 Description PHOENIX CONTACT - 05/2008 Features STEP POWER power supply units for building automation The new
More informationBKS. Contents Connectors and accessories. Micropulse Transducers
Contents and accessories KS. Connector overview KS. for nalog, Pulse and SSI KS.4 and accessories for CNopen and DeviceNet KS.6 and accessories for PROFIUS-DP interface KS.8 for Profile series KS for nalog,
More informationFL SWITCH SFNB. Five- and Eight-Port Standard Function Ethernet Switch with Narrow Housing. AUTOMATION Data Sheet 2642_en_H.
Five- and Eight-Port Standard Function Ethernet Switch with Narrow Housing AUTOMATION Data Sheet 2642_en_H 1 Description PHOENIX CONT 2011-07-10 2 Features and Benefits The FL SWITCH SFNB Factoryline switches
More information1-Conductor Female Connector with Levers Pin Spacing: mm MCS MAXI 16
-Conductor Female Connector with evers Pin Spacing: 0.6 mm MCS MAXI 6 Intuitive and tool-free lever actuation Universal connection for all conductor types Push-in termination of solid or ferruled conductors
More informationFL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B
Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections Data sheet 3379_en_B 1 Description PHOENIX CONTACT 2015-07-14 2 Features Media converters provide
More informationModular Connectors 75
75 Plug/Jack Compliant to Enhanced Category 5 standards Connector type Size Series Name Page plug connectors compliant to enhanced category 5 standards 8 TM21P 77 jack connectors for high-speed LAN transmission
More informationIBS ST 24 BK-T INTERBUS-S. Data Sheet. Bus Terminal Module. Product Description
IBS ST 24 BK-T Data Sheet INTERBUS-S Bus Terminal Module Data Sheet Revision A 08/994 Product Description The IBS ST 24 BK-T bus terminal module is the head station for an INTERBUS ST compact station in
More informationCONTA-ELECTRONICS. Interface modules
CONTA-ELECTRONICS allow for a passive mechanical-electrical implementation of standard connectors onto screw or tension-spring PCB terminals. The individual signals of the multi-pole or high-pole connectors
More informationDocumentation KL channel Digital Output Terminal, 24 V DC, 2 x 4 A/1 x 8 A. Version: Date:
Documentation 2 channel Digital Output Terminal, 24 V DC, 2 x 4 A/1 x 8 A Version: Date: 1.0.0 2016-08-12 Table of contents Table of contents 1 Foreword... 4 1.1 Notes on the documentation... 4 1.2 Safety
More informationME PLC Multifunctional housing for complex electronics. Data sheet _en_01. 1 Description
Multifunctional housing for complex electronics Data sheet 105504_en_01 PHOENIX CONTACT 2013-04-08 1 Description The housings of the ME PLC 40... product group consist of a 40-mm wide housing base with
More informationMobileView Junction Box
Installation Instructions MobileView Junction Box (Catalog Number 2727-MRJB2) English The MobileView Junction Box (2727-MRJB2) integrates the following terminals into the control system: MobileView Guard
More informationUninterruptible Power Supply Unit for Universal Use QUINT-DC-UPS/24DC/40
Uninterruptible Power Supply Unit for Universal Use QUINT-DC-UPS/4DC/40. Short Description Uninterruptible Power Supply Units for Buffering Long-Term terruptions Saves space thanks to the compact, uniform
More informationMale header, 100% protected against mismating, (1 x 1) mm straight solder pins Pin spacing 3.5 mm 3.81 mm. light gray <_ 8,5_> 3,5 1x1 <_ 9,3_>
96 Male Headers with Solder Pins; Double-Deck Male Headers with Solder Pins, Pin Spacing 3.5 mm and 3.81 mm 160 V/.5 kv/ 300 V, 10 A U 10 A 300 V, 10 A 160 V/.5 kv/ 300 V, 10 A U 10 A 300 V, 10 A 160 V/.5
More informationPCAN-Repeater DR CAN Repeater for the Decoupling of Bus Segments. User Manual. Document version ( )
PCAN-Repeater DR CAN Repeater for the Decoupling of Bus Segments User Manual Document version 2.0.0 (2018-02-20) Relevant products Product Name Model Part number PCAN-Repeater DR Industry IPEH-004038 PCAN
More information1. Mount the echo and tremolo control switches under the keyboard shelf, in a position convenient for the organist.
CONSOLE CONNECTOR KIT 8101 INSTALLATION INSTRUCTIONS FOR USE WITH: HAMMOND Organ Models A-100, D-100, RT2, RT3 LESLIE Speaker Models 122, 122RV KIT CONTENT Console Connector Assembly 047357 Echo Control
More informationData sheet C6 A modul 90 jack
Illustrations Dimensional drawing Cut-out Page 1/7 See enlarged drawings at the end of document Product specification modular Cat.6 A termination unit RJ45 mounting version: module, 90 cable feed solid,
More informationMINI-PS AC/10-15DC/8
Primary-Switched Power Supply, Narrow Design Data Sheet 08/2004 MINI POWER provides: An extra narrow design, with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a
More informationWINSTA. Full Line Catalog 2008/2009
WINSTA Full Line Catalog 2008/2009 5 Contents FULL LINE CATALOG W4, Volume 1 Rail-Mounted Terminal Block Systems FULL LINE CATALOG W4 Rail-Mounted Terminal Blocks Volume 1 X-COM -SYSTEM Terminal Strips