SRW01. Smart Relay. Motors Automation Energy Coatings USASRW09. g Modular concept. g Network communication. g Built in motor protection
|
|
- Gordon Manning
- 6 years ago
- Views:
Transcription
1 Motors Automation Enery Coatins SRW01 Smart Relay Modular concept Network communication Built in motor protection State of the art tech USASRW09
2 Smart Relays - SRW01 Series The SRW01 is a low-voltae electric motor manaement system with state-of-the-art technoloy and network communication capabilities. Additionally, its modular concept allows to be used in various applications. Versatility The SRW01 supports the followin communication networks protocols: DeviceNet, Modbus-RTU, and ProfiBus-DP. The communication modules can be easily exchaned due to plu-and-play capabilities. A HMI also can be used for quick system monitorin and relay parameterization. Additionally, the SRW01 provides a USB port for relay monitorin and prorammin throuh PC when usin WLP software. The SRW01 includes a thermal memory circuit in order to maintain a motor thermal imae, even if power supply is removed. Flexibility The SRW01 modular concept allows easy functionality expansions. The control unit can also be mechanically assembled with the control measurement unit or separately (up to 2 meters), allowin system interation versatility. The relay offers pre-prorammed operatin modes that perform various types of standard startin or monitorin conditions. Its friendly parameterization mode allows users to proram the relay accordin to their needs ASK-4WEG
3 Modular Desin The SRW01 incorporates a main control unit (SRW01-UC) and a current measurement unit (SRW01-UMC) to provide flexible assembly options. The SRW01-UC and SRW01-UMC are electrically connected usin the SRW01-CB flat cable. The interface with the relay may be performed in three ways: Via Fieldbus (ModBus, DeviceNet, Profibus) Via Keypad (SRW01-IHM) Via software WLP (USB) Throuh Fieldbus, the user can operate, monitor, and confiure the SRW01 remotely, via PLC or supervisory system. Data is subject to chane without notice. WEG Automation - Products and Solutions 3
4 Characteristics The SRW01 relay has a Vac / Vdc supply voltae rane, with I0 either 24 Vdc or 110 Vac makin system interation flexible. The reduced size of SRW01-UC, with a width of 45mm and heiht of 100mm, make it a compact product Reset ProfiBus - DP network connection Mini USB port Connection for HMI and accessories ModBus, DeviceNet or ProfiBus - DP connection Communication module The SRW01-UC control unit provides LED indicators for input and output activations, status, operation mode, power supply status, failure and alarm status. The mountin of the control unit can be done either by 35mm DIN rail or onto back panel mountin. Communication protocols: DeviceNet, Modbus, and Profibus are defined usin proper protocol installed in the communication drawer. The plu and play concept automatically reconizes and confiures the SRW01 for safe operation avoidin manual error connections ASK-4WEG
5 Current Measurin Units The current measurin unit SRW01-UMC shall be chosen accordin to motor rated current from 0.25A throuh 840A Width (mm) Current (A) Power connection Cable throuh UMC Width (mm) Current (A) Power connection Cable throuh UMC Width (mm) Current (A) Power connection Busbar Width (mm) Current (A) Power connection Cable throuh UMC or busbar SRW01-CB connection cable The SRW01-CB connects the controls units SRW01-UC to the current measurin unit SRW01-UMC allowin the two units to be separated assembled up to 2 meters. Data is subject to chane without notice. WEG Automation - Products and Solutions 5
6 Functions The SRW01 protection, monitorin and operatin functions enhance system protection, reliability, and precision. The operatin modes are auto-adjustable, meanin that the user selects the operatin mode and the relay search for proper parameters automatically. This feature ensures quick and safe parameterization. All operatin modes allow motor monitorin. Its friendly parameterization mode allows users to access all diital inputs and outputs, thus increasin flexibility to cover many applications. Protection Operatin Modes Overload protection (adjustable trippin class 5-45). Thermal protection via PTC. Phase loss protection. Protection aainst current umbalance between phases. Protection aainst overcurrent and locked rotor. Protection aainst undercurrent. Internal round fault protection. Protection aainst out of rane frequency. Monitorin Diital input and output activation. RMS current of each phase and averae in amperes or % of In adjusted current. Motor frequency Number of activation per failute type. Number of start ups. Motor runnin hours. Relay runnin hours. Phase umbalance levels. Internal round fault current. Transparent operation - Diital input and output can be confiured accordin to application needs. Operation as overload relay similar to an overload relay. Direct starter - direct-on-line starter for sinle and three phase motors Reversin starter - reversin starter for three phase motors. Star-Delta starter - star-delta starter for three phase motors. Dahlander starter- starter for Dahlander three phase motors. Two windins starter - starter for two windins three phase motors. PLC mode similar to the runnin of a PLC. In this mode the SRW01 UMC is not used ASK-4WEG
7 WLP Software The WLP is the SRW01 confiuration software for Windows environment with user friendly interface that enables system parameterization, prorammi, controllin and monitorin. The WLP software enables the user to confiure the relay, edit parameters and proram in LADDER. Throuh the WLP confiuration assistants the user has a uided routine that enables relay confiuration. When necessary, the relay can be prorammed in LADDER usin mathematical and control blocks. The LADDER proram has a 64 Kbyte memory and can use the relay diital inputs and outputs. Communication between software and relay can be performed throuh USB port or ModBus network. The WLP software is free and supplied with the product. It can be also obtained from the website Confiuration Assistants These routines have been especially created to assist relay confiuration. They help the user to confiure the relay in an easy self explanatory manner. Confiuration Assistant: Control Confiuration. Monitorin Dialoues These dialoues have been especially created to monitor the relay. They monitor exclusive relay information. Monitorin dialoues: Dianostic. Data is subject to chane without notice. WEG Automation - Products and Solutions 7
8 Applications The main function of the SRW01 is to protect and control electric motors in their most diverse industrial applications. Due to its reduced size and modular desin, the relay is frequently used when space for its assembly is a determinin point, e.. in Intellient Motor Control Centers. Its hih reliability and precision make the SRW01 suitable for the touhest industrial applications. The on-line monitorin options, failure dianosis and failure statistics allow preventive maintenance to be more effective, thus reducin the number of downtimes. It offers wide application for continuous process plants in the followin market sements: Chemical and Petrochemical Pulp and Paper Minin and Cement Food and Beverae Metal and Fabrication Plastics and rubber Automotive Ceramics Textile Refrieration Other sements Benefits Greater reliability for the protection system Operator safety in operation, supervision and maintenance. System modularity and easy expansion. Reduction in control wirin. Reduction in motor control hardware. Remote monitorin, supervision and control via fieldbus network, computer (WLP) or Human-Machine Interface. Remot reset of the relay Quick and precise defect identification. Automation in defect records and statistics ASK-4WEG
9 Technical Characteristics Assembly position Any Deree of protection (IEC 60529) UC - Control Unit IP20 Current measurement: - without connection bus bar IP20 - with connection busbar IP00 Human Machine Interface (HMI) IP20 Acceptable ambient temperature: - Operation ºC ( F) - Strorae and transport ºC ( F) UC - Control Unit Insulation Rated Voltae Ui 300V Supply Rated Voltae Us Vac/Vdc a 50/60Hz Operatin rane 0.90Us Us Consumption 13W Number of diital inputs 4 optically insulated inputs Number of diital outputs 4 relay outputs Motor protection via PTC: - TRIP value > 3.9kΩ - Rearm value < 1.6kΩ Terminals (connectors) - Torque Nm ( lb-in) Conductor diameter: Riid and no end sleeve 1 x ( mm 2 ); 2 x ( mm 2 ) Flexible with/without terminals 1 x ( mm 2 ); 2 x ( mm 2 ) RESET button Error or failure reset System TRIP or alarm reset - Protections Current Measurin Unit (UMC) Current ranes Aac Deree of insulation Ui 690Vac Operatin rated voltae Ue - IEC Vac - UL Vac Impulse voltae Uimp 6kV Motor rated frequency Up to 99Hz Application Sinle phase and three phase Diameter for cables: SRW01-UMC1, SRW01-UMC2, SRW01-UMC3 8mm SRW01-UMC4 15mm SRW01-UMC5 Busbar SRW01-UMC6 31mm or busbar Diital inputs Number of diital inputs 4 optically insulated inputs Source for diital inputs 24Vdc internal source (insulated) Diital inputs current 11mA to 24Vdc Insulation 3kV Diital outputs Number of diital outputs 4 relay outputs Contact roupin 2 SPST 2 SPST commom shared Contact voltae rane Vac/Vdc Lowest operatin power 1W or 1 VA Operatin capacity per relay contact: CONTROLS AC-15 (IEC ) DC-13 (IEC ) External protection aainst short circuit Mechanical life Electrical life (AC-15): Electrical life (DC-13): 6 A / 24 Vac 6 A / 120 Vca 3 Aac / 230 Vca 2 A / 24 Vdc 0.55 A / 60 Vdc 0.25 A / 125 Vdc 6 A L/G fuse operations operations (0.5 A/250 Vac) operations (1.5 A/250 Vac) operations (0.5 A/250 Vdc) operations (1.5 A/250 Vdc) Data is subject to chane without notice. WEG Automation - Products and Solutions 9
10 Dimensions (mm) SRW01-UC - Control Unit SRW01-UMC - Current Measurin Unit UMC 1- UMC 2- UMC ASK-4WEG Data is subject to chane without notice.
11 Dimensions (mm) SRW01-UMC - current Measurin Unit UMC 5 UMC 6 (with busbar) HMI - Human Machine Interface UMC 6 (without busbar) WEG Automation - Products and Solutions 11
12 Please contact your authorized distributor: USASRW09 WEG Electric Corp Suarload Parkway Duluth, GA Phone: ASK-4WEG web:
SSW07 Soft Starter. Tough. Durable. Quality. Phone: Fax: Web:
Motors Automation Enery Transmission & Distribution Coatins Soft Starter Touh Reliable Durable Quality Soft Starters are static startin devices, desined for the acceleration, deceleration and protection
More informationSRW01 Smart Relay. Motors Automation Energy Transmission & Distribution Coatings
SRW01 Smart Relay Motors Automation Enery Transmission & Distribution Coatins www.we.net Smart Relay SRW01 Sumary Overview 04 Features 06 Modular Desin 07 Benefits 09 Functions 09 Applications 10 Selection
More informationMotors Automation Energy Coatings. CFW11 Drive. g Tough. g Reliable. g Durable. g Quality USACFW1109
Motors Automation Enery Coatins Drive Touh Reliable Durable Quality USA09 www.we.net Vectrue Inverter The WEG series of inverters includes state-of-the-art technoloy for three-phase induction motor control.
More informationMotors Automation Energy Coatings. CFW08 Drive. g Tough. g Reliable. g Durable. g Quality USACFW08
Motors Automation Enery Coatins CFW08 Drive Touh Reliable Durable Quality USACFW08 www.we.net CFW08 Plus, Multipump, and Wash The WEG CFW08 Series of drives features the compact size of a microdrive yet
More informationVariable Frequency Drives
www.we.net WEG's uses state-of-the-art technoloy to control motors up to 600HP. Aimed at increasin customers productivity, the offers the followin innovations: Applications Standard Features Pumps Fans
More informationIMS Control & EPR, We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp
IMS Control & EPR, 2010 01 29 We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp October 27, 2010 1SBC101089D0201 ABB s new control and protection devices Up to 18.5
More informationMotor protection relays
Thermal overload relays for currents between 0.09 and 420A Electronic thermal overload relays for currents between 0.4 and A Electronic thermal overload relays with selectable tripping class: 5--20-30
More informationMotor control and protection Universal Motor Controller UMC100-FBP
Motor control and protection Universal Motor Controller UMC100-FBP Universal motor controllers from ABB the intelligent on-site solution. Large industrial plants often contain several thousand motors in
More informationE1 Plus Electronic Overload Relay
ROCKWELL AUTOMATION PROCUREMENT SPECIFICATION PROCUREMENT SPECIFICATION E1 Plus NOTICE: The specification guidelines in this document are intended to aid in the specification of products. Specific installations
More informationSIMOCODE 3UF Motor Management and Control Devices
Technical specifications General data applicable to the basic units, current measuring modules, current/voltage measuring modules, expansion modules, decoupling module and operator panel Permissible ambient
More informationUniversal Motor Controller UMC22-FBP. Excellent motor protection and control ATEX ABB
Universal Motor Controller UMC-FBP Excellent motor protection and control ATEX ABB FieldBusPlug: the concept ABB s communicative product family comprises a wide range of switching, controlling and automation
More informationPOWER ELECTRONICS / SD700 SERIES SD700 VARIABLE SPEED DRIVES
POWER ELECTRONICS / SD700 SERIES SD700 VARIABLE SPEED DRIVES SD700 SERIES is the core of the family, available from 1.5kW to 2200kW [1], a voltage range from 230VAC to 690VAC and available 6, 12, 18 and
More information29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.
www.factorymation.com/motorcontrols MOTOR CONTROLS 25 Manual Motor Starters High interrupt capacity Din rail and surface mounting Lockable handle (OFF position) IP20 finger safe terminals Class 10 thermal
More informationMotors Automation Energy Transmission & Distribution Coatings. Profibus DP SRW 01. User s Manual
Motors Automation Energy Transmission & Distribution Coatings Profibus DP SRW 01 User s Manual Profibus DP User s Manual Series: SRW 01 Firmware Version: V6.0X Language: English Document Number: 10000521541
More informationELR W1/ 6-24DC. Extract from the online catalog. Order No.:
Extract from the online catalog ELR W1/ 6-24DC Order No.: 2982090 Illustration shows item ELR W1/ 6-24DC Electronic reversing load relay, for driving DC motors, with light indicator and protection circuit,
More informationRW-E. Overloads. Solid-State Overload Relays. Standard Features
RW-E The new RW_E Solid State Overload relays are developed with cutting edge technology according to the most demanding standards worldwide. With its wide current/mp setting; the RW_E OL Relay can be
More informationDigiplex IV A Matrix Switching Control System for Large CCTV Installations
www.gesecurity.com Overview Diiplex IV A Matrix Switchin Control System for Lare CCTV Installations Diiplex IV is an expandable matrix switchin system that manaes video inputs and monitor outputs. It is
More informationMIC-2 MKII, Multi-instrument DATA SHEET
MIC-2 MKII, Multi-instrument DATA SHEET Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional)
More informationOVERLOAD RELAYS POWER & ACTUATION PROVEN. series
POWER & ACTUATION OVERLOAD RELAYS series Need reliable, accurate overload and phase-loss protection for your motors? c3controls Series Bimetallic Overload Relays provide unmatched protection and can be
More informationEXPANSION PERIPHERAL CVM-R10 C. (Code ) INSTRUCTION MANUAL ( M / 00 A ) (c) CIRCUTOR S.A.
EXPANSION PERIPHERAL CVM-R10 C (Code 7 70 217 ) INSTRUCTION MANUAL ( M 981 170 / 00 A ) (c) CIRCUTOR S.A. ------ CVM-R10 C Peripheral --------------- Pag. 1 CVM-R10C EXPANSION PERIPHERAL 1.- DESCRIPTION
More informationMini Contactors & Overloads
108 Mini s & Overloads GMC-12M Surface or DIN rail mountable UL508 compliant 1/ to 7-1/ 50/60Hz AC and DC versions available Direct-mounting overloads RoHS compliant Auxiliary contacts standard (1 N.0.)
More informationAlberto Carini, LPLS Italy, June 2013 MNS is The Intelligent MCC. ABB Group June 21, 2013 Slide 1
Alberto Carini, LPLS Italy, June 2013 MNS is The Intelligent MCC June 21, 2013 Slide 1 The MCC evolution Traditional MCC Intelligent relays MCC with integrated intelligence June 21, 2013 Slide 2 The intelligent
More informationSIRIUS Motor Management and Control Devices
Overview is a flexible, modular motor management system for motors with constant speeds in the low-voltage performance range. It optimizes the connection between the control system and motor starter, increases
More informationAutomation Molded Case Circuit Breakers IEC Style. Motors Automation Energy Transmission & Distribution Coatings
Automation Molded Case Circuit Breakers IEC Style Motors Automation Enery Transmission & Distribution Coatins www.we.net Molded Case Circuit breakers Molded Case Circuit Breakers Summary Molded Case Circuit
More informationEnclosed Starters. Operation and Protection of Motors up to 75Hp at 460Vac (100A) Motors Automation Energy Coatings USAESW09
Motors Automation Enery Coatins Enclosed Starters Operation and Protection of Motors up to 75Hp at 460Vac (100A) Compact starter Price competitve Hih KAIC ratins Products in stock USAESW09 Combination
More informationSMART RELAY SRW 01 V4.0X
Motors Automation Energy Transmission & Distribution Coatings SMART RELAY SRW 01 V4.0X Profibus DP Communication Manual Profibus DP Communication Manual Series: SRW 01 Firmware Version: V4.0X Language:
More informationwww. ElectricalPartManuals. com l Basler Electric MPS100 MOTOR PROTECTION SYSTEM ADVANTAGES WINDOWS SOFTWARE ADDITIONAL INFORMATION
The Motor Protection System is a microprocessor based digital relay which provides comprehensive motor protection including metering, communications, data recording and diagnostics. ADVANTAGES Extensive
More informationISOMETER isoev425/isoev425hc with coupling device AGH420
with coupling device AGH420 Insulation monitoring device for unearthed DC circuits (IT systems) for charging electric vehicles isoev425_d00126_04_d_xxen/06.2018 with coupling device AGH420 Insulation monitoring
More informationSSW06. Soft Starters. Applications. Standard Features. Pumps Fans Blowers Compressors Crushers Saws Grinders Mixers.
General Information CFW10 CFW100 CFW08 CFW500 CFW700 CFW701 CFW11 EDP11 CFW11M SSW05 SSW07 GPH2 TPH2 The is WEG s third generation Soft Starter line. The keypad, with dual display, has red LED digits which
More informationSENSORLESS VECTOR CONTROL
D SERIES EM16 STANDARD DRIVE SENSORLESS VECTOR CONTROL EM16 STANDARD DRIVE SENSORLESS VECTOR CONTROL 1 2 SERIES 1 2 page 4 page 6 Introduction Fields of application 3 page 7 4 page 8 Designation Product
More informationThe safety control of the next generation
samos pro samos pro compact The safety control of the next generation With the highest power in the smallest space, the safety control samos pro compact sets new standards in the area of machine automation.
More informationSSW06. Soft Starters.
The is WEG s third generation Soft Starter line. The keypad, with dual display, has red LED digits which provide visibility and make programming easier. Integral bypass contacts eliminate heat dissipation
More informationTeSys IEC Contactors and Overload Relays
TeSys IEC Contactors and Overload Relays Making High-Fault Short-Circuit Current Ratings Simple Schneider Electric is an industry leader in IEC contactors and overload relays, and is recognized as the
More informationBulletin 825-P Modular Protection System
Bulletin 825-P Modular Protection System Bulletin 825-P 120/240V AC and 24/48V DC Control Power Suitable for low- and medium-voltage applications Modular design with pluggable options Voltage input card
More informationWEG Contactors - CWM and CWME Series
Inside (877) 789 Fax () 87 WEG Contactors CWM and CWME Series International () 07 The CWM generalpurpose contactor line has been designed taking into consideration industrial duty and reliability in mind.
More informationMIC-2 Multi-instrument DATA SHEET
Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional) Profibus DP (optional) I/O modules
More informationQuantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III
Compact DC Drive Package The delivers a DC drive package that integrates the intelligence of the Mentor II with a space saving design that incorporates many accessories typically required in the North
More informationlow voltage GLOBAL CATALOGUE RANGE Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters
CTLOGUE GLOBL RNGE 2. Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters 2. 2. Product Overview. 2.2 Overload Relay Setting Range 2. - 2.8 Product Specifications 2.9-2. Contactor
More informationPluto AS-i. Safety PLC. Approvals: Control of: Features:
Safety PLC Pluto AS-i Approvals: TÜV Rheinland Control of: Safety products in dynamic and static circuits as well as in AS-i networks Electrically controlled actuators such as contactors, valves, motors
More informationProfinet Module. User Manual. Contents
User Manual Contents 1 Important User Information... 2 2 Installation... 3 3 Connection... 4 4 Device Configuration... 5 5 Operation... 7 6 Packet Structures... 8 7 Network Design... 16 8 Specifications...
More informationXPSMC16ZP safety controller XPS-MC - 24 V DC - 16 input - 32 LEDs signalling
Characteristics safety controller XPS-MC - 24 V DC - 16 input - 32 LEDs signalling Main Range of product Product or component type Safety module name Mar 09, 2017 Preventa Safety automation Configurable
More informationMIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET
& DIN, Multi-instrument DATA SHEET Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional)
More informationElectrical measurement and control Maximum demand control systems
Electrical measurement and control Maximum demand control systems M.6 M. 6 Maximum demand control systems M.6 - Maximum demand control systems Introduction 3 Product selection table 5 DH96 CPP Digital
More information2 Table of Contents 1. TABLE OF CONTENTS. 1. Table of Contents Introduction Wiring Diagram Terminals Review...
TPR-6 Temperature Protection Relay Instruction Manual Ver. June 1 st 2010 2 Table of Contents 1. TABLE OF CONTENTS 1. Table of Contents... 2 2. Introduction... 3 3. Wiring Diagram... 5 4. Terminals Review...
More informationvacon nx user manual basic i/o boards expander i/o boards adapter i/o boards ac drives
vacon nx ac drives basic i/o boards expander i/o boards adapter i/o boards user manual vacon 2 General information. GENERAL INFORMATION VACON NX range embodies a wide selection of expander and adapter
More informationISOMETER isoev425 with coupling device AGH420
with coupling device AGH420 Insulation monitoring device for unearthed DC circuits (IT systems) for charging electric vehicles Preliminary datasheet isoev425_d00126_02_d_xxde/09.2015 with coupling device
More informationSmartWire-DT Connectivity
SmartWire-DT Connectivity DS7 Soft Start Controllers DC1 Drives XTPE MMPs SL4/SL7 Stacklights 2 SmartWire-DT DS7 Soft Start Controllers Two phase SCR control with patented algorithm Suitable for variable
More informationDigistart. Soft starters for 3 phase induction motors 7.5 to 800kW (18 to 1600A) 200V, 400V, 575V, 690V
Digistart Soft starters for 3 phase induction motors 7.5 to 800kW (18 to 1600A) 200V, 400V, 575V, 690V Digistart Digistart is Control Techniques flexible soft starter range for motor control and protection
More informationPower Xpert C445 Competitive Comparison
Power Xpert C445 Competitive Comparison CPCD Product Line April 2015 Benefit over all competitors Advanced monitoring / control algorithms Motor efficiency, peak demand alarming, motor torque Eaton C445
More informationMULTI 9 System Catalog UL Recognized C60N Supplementary Protectors
UL Recognized C60N Supplementary Protectors B Curve C60N Supplementary Protectors 1 MG24110 MG24125 MG24140 MG24155 15 MG17406 MG17436 MG17461 1.2 MG17402 MG17432 16 MG24118 MG24133 MG24148 MG24163 1.5
More informationPower supply. Interface technology in modular housing DIN rail devices, IM series. Features
Features 2,2 kò,5 W 5 V 5,1 V,3 W 24 VDC 2,5 A GN / L 85...264 VAC 9...375 VDC / N Safety extra-low voltage SELV IEC/ EN 695 Output voltage adjustable 24 28 VDC Nominal current 2.5 A Single/parallel operating
More informationATS Automatic transfer switches Advanced version
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 ATS CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. ELECTRICAL AND MECHANICAL CHARACTERISTICS 2 5. CONFORMITY 4 6. EQUIPMENTS
More informationUniversal Motor Controller UMC22-FBP. High-grade Motor Protection and Control
Universal otor Controller UC-FBP High-grade otor Protection and Control The FieldBusPlug concept This new ABB product family is a communication device range with switching and automation components which
More informationOTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) Areas of Application
Miniature Circuit Breakers Areas of Application Miniature circuit breakers (MCBs) of the N-System primarily protect cables and conductors against overload and short circuit. Thus, they also protect electrical
More informationSentron 3VT circuit breakers Simply Smart: First choice for power distribution
s Sentron 3VT circuit breakers Simply Smart: First choice for power distribution www.siemens.com/industry Sentron 3VT Molded Case Circuit-Breakers - 10-1600Amperes With the standard line of 3VT molded-case
More informationMNS with M10x Intelligent motor management
PRODUCT BROCHURE MNS with M10x Intelligent motor management A reliable, available, simple, safe and powerful MNS solution MNS with M10x Intelligent motor management 2 M N S W I T H M 1 0 X I N T E L L
More informationLowering Lifecycle Costs
Lowering Lifecycle Costs with Intelligent Motor Control Centers Standards Certification Education & Training Publishing Conferences & Exhibits Speakers: Presented and Authored by Jeff M. Miller, PE, ENV
More information1.3. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZS Circuit Breaker. UL 1077 DIN Rail Supplementary Protectors
. Miniature Circuit Breakers and Supplementary Protectors UL 077 DIN Rail Supplementary Protectors WMZS Circuit Breakers Contents Description WMZS Circuit Breaker Standards and Certifications................
More informationXPSMC16Z safety controller XPS-MC - 24 V DC - 16 input - 30 LEDs signalling
Characteristics safety controller XPS-MC - 24 V DC - 16 input - 30 LEDs signalling Main Range of product Product or component type Safety module name Sep 30, 2018 Preventa Safety automation Configurable
More informationTechnical data. Safety parameters: see page 333. DC maximum residual ripple: 10% Supply voltage tolerance: DC consumption: Control circuit
Safety module CS DM-01 Technical data Housing PA 6.6 polyamide housing, self-extinguishing, V0 acc. to UL 94 Protection degree IP40 (housing), IP20 (terminal strip) Dimensions see page 283, design A Two-hand
More informationOverloads. RW Series Catalog Number Sequence. RW Series - Bi-Metallic Thermal Overload Relays. Standard Features 3 - RW 27-1D
Circuit Protection Disconnect Switches Thermal Overload Relays n extended operational service life is one of the main features you can find in RW overload relays. WEG s RW Thermal Overload Relays are designed
More informationNemo SX - Multifunction control module
Via Travaglia 7, 20094 Corsico (MI) - Italia Tel. +39 0244878.1 - Fax +39 024503448 Contents Pages 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection... 1 5.
More informationINTRODUCING THE S V ADJUSTABLE SPEED DRIVE
MOTORS & DRIVES ADJUSTABLE SPEED DRIVES (ASD) GROUP INTRODUCING THE S15 600 V ADJUSTABLE SPEED DRIVE Extreme Performance Micro-Drive - Heavy Duty, Compact, and Durable ASD SUPPORT NEWS: Toshiba s heavy
More informationProgrammable Logic Controllers. and Components for Industrial Automation. altus. evolution in automation.
Programmable Logic Controllers and Components for Industrial Automation altus www.altus.com.br evolution in automation Segmentation Every automation system features unique characteristics that require
More informationXPSMC16ZPPACK safety controller XPS-MC - 24 V DC - 16 input - 32 LEDs signalling
Characteristics safety controller XPS-MC - 24 V DC - 16 input - 32 LEDs signalling Main Range of product Product or component type Safety module name Sep 11, 2018 Preventa Safety automation Kit configurable
More informationUL 489 Cable-In / Cable-Out Branch Circuit Breaker
Product Overview UL 9 Cable-In / Cable-Out Branch Circuit Breaker PRODUCT OVERVIEW Optimum and Efficient Protection Features Complete range of UL 9 listed DIN rail mounted miniature circuit breakers up
More informationUL 489 DIN Rail Miniature Circuit Breakers
UL 489 DIN Rail Miniature Circuit Breakers Product Overview................................................ 2 Product Selection................................................ 4 Accessories.....................................................
More informationOne relay for safety and process continuity
Motor Management Relay One relay for safety and process continuity Improve safety at each motor control center (MCC) with secure, fast arc-flash detection. Use the enhanced thermal model for more precise
More informationSENTRON 3VL Molded Case Circuit Breakers
Siemens AG SENTRON VL Molded Case Circuit Breakers Switching, Protection, Measuring and Monitoring Devices For the operating range from A to 00 A, the molded case circuit breaker ensures the optimum overload
More informationIssued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog
Issued February 2011 DATA SHEET 5SX2 MCB Based on Siemens Industrial Control Catalog General Data Trip characteristics Tripping characteristics acc. to EN 60 898 Tripping characteristic A, -5 Type A characteristic
More informationPM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features
PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER The PM174 is a compact, multi-function, three-phase AC powermeter and power quality analyzer specially designed to meet the requirements of users ranging
More informationXPSMC16Z safety controller XPS-MC - 24 V DC - 16 input - 30 LEDs signalling
Characteristics safety controller XPS-MC - 24 V DC - 16 input - 30 LEDs signalling Complementary Function of module Synchronisation time between inputs Power consumption Input protection type [Uc] control
More informationSACE Emax 2 Specification guide
SACE Emax 2 Specification guide Specification Number: 26 01 20.17 Product Name: LOW VOLTAGE POWER CIRCUIT BREAKERS PART 1 GENERAL NOTE: ( ) Indicates option or a selection is to be made for quantity or
More information24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD
United States 24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Approvals: IEC 60947-2 Rated
More informationXPSMC32Z safety controller XPS-MC - 24 V DC - 32 input - 46 LEDs signalling
Characteristics safety controller XPS-MC - 24 V DC - 32 input - 46 LEDs signalling Complementary Main Commercial Status Range of product Product or component type Safety module name Commercialised Preventa
More informationRM35TF. Main. Product or component type. Product specific application. Relay monitored parameters 250 V AC 5 A AC
Characteristics multifunction phase control relay RM35-T - range 194..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage
More informationPage 5-3. Page 5-2 Page 5-3
Page -2 Page -3 Page -3 ADXC Two phase control IEC rated starter current Ie 12 to 4A IEC rated motor power.-22kw at 400VAC and 9-37kW at 600VAC UL/CSA ratings 3 to 2HP at 400VAC and 10 to 40HP at 600VAC
More informationMICROFUSION FEATURES OPTIONS CERTIFICATIONS (PENDING) THREE PHASE SCR POWER CONTROLLERS
MICROFUSION THREE PHASE SCR POWER CONTROLLERS FEATURES Auto-Ranging Input Voltage 24-600 VAC, 45-65 Hz AC Output 16, 32, 50, 80 Amps (@ 50 C 6000 ft) Control Features Microprocessor-based controller /
More informationMNS Platform, low voltage systems Rear Access Power Motor Control Center. Alberto Carini, Global Product Manager
MNS Platform, low voltage systems Rear Access Power Motor Control Center Alberto Carini, Global Product Manager MNS Platform, low voltage systems Add Value to our customers Sales After sales Maximum safety;
More informationEthernet/IP Module. User Manual. Contents
User Manual Contents 1 Important User Information... 2 2 Installation... 3 3 Connection... 4 4 Device Configuration... 5 5 Operation... 8 6 Packet Structures... 9 7 Network Design... 18 8 Specifications...
More informationPGR-3200 MANUAL INSULATION MONITOR
Tel: +1-800-832-3873 E-mail: techline@littelfuse.com www.littelfuse.com PGR-3200 MANUAL INSULATION MONITOR REVISION 3-E-040918 Copyright 2018 by Littelfuse, Inc. All rights reserved. Document Number: PM-1025-EN
More informationADXL Series SIMPLE, EFFICIENT AND SAFE MOTOR CONTROL
SOFT STARTERS ADXL Series SIMPLE, EFFICIENT AND SAFE MOTOR CONTROL Simplicity The ADXL series of soft starters is equipped with a backlit LCD icon display and NFC connectivity for quick and easy configuration,
More informationUL 489 DIN Rail Miniature Circuit Breakers
UL 9 DIN Rail Miniature Circuit Breakers Product Overview................................................ Product Selection................................................ Accessories.....................................................
More informationRM4JA32MW current measurement relay RM4-J - range A V AC DC
Characteristics current measurement relay RM4-J - range 0.3..15 A - 24..240 V AC DC Main Range of product Product or component type Relay type Relay name Relay monitored parameters Power consumption in
More informationCATALOG SELECTION / PRODUCT SELECTION
catalog selection / product selection Motor Control Drives CATALOG SELECTION / PRODUCT SELECTION M-Max Machinery Drive Catalog Numbering System MMX AA D F - 0 Base Catalog Number Option Drives Phase =
More informationRM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA 250 V AC
Characteristics phase control relay RM17-T - range 183..484 V AC Complementary Maximum switching voltage Minimum switching current [Us] rated supply voltage Supply voltage limits Control circuit voltage
More informationEMS CX 3 - State and control module for Latching relays and Contactors
87045 LIMOGES Cedex Telephone : 05 55 06 87 87 Fax: 05 55 06 88 88 EMS CX 3 - State and control module Contents Pages 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation -
More informationVariTrans A The specialist for ±10 V and ±20 ma. With calibrated range selection and broad-range power supply.
Universal Isolation Amplifiers The specialist for ±10 V and ±20 ma. With calibrated range selection and broad-range power supply. The Housing At a width of just 12.5 mm, the modular housing with pluggable
More information1. Warnings Introduction Mechanical Installation Electrical Installation Application Examples...
MCD 500 Operating Instructions Contents Contents 1. Warnings... 3 2. Introduction... 4 2.1. Feature List... 4 2.2. Type Code... 5 3. Mechanical Installation... 6 3.1. Mechanical Installation... 6 3.2.
More informationSignal Doublers. VariTrans A 20300
ProLine Interface Technology Signal Doublers Signal doublers with two switchable calibrated outputs in a 6 mm housing, also for applications with high output loads. The Task Isolation and transmission
More informationPositive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous
Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of
More informationSeries CEP9 Electronic Overload Relays
Series CEP9 Electronic Overload Relays Choose Series CEP9 overloads for advanced communication and motor protection The CEP9 Electronic Overload Relay is an advanced electronic overload from Sprecher +
More informationVoltage Transducer UMT516 / MT516
Voltage Transducer UMT516 / MT516 True RMS AC voltage measurements Voltage auto range measurements up to 600V # Wide frequency measurement range 16 400 Hz High accuracy class 0.2 (IEC-688), 0.1 on communication
More informationSupplementary Circuit Protectors Type GSB63
Supplementary Circuit Protectors Type GSB63 l Protection of circuits against short circuit and overload currents l UL1077 supplementary protection l 1,, 3 and 4 pole arrangements l 13 amperage sizes up
More informationQuasar Series Technical Features
Product Description The Quasar Series is a modern imcc (Intelligent Motor Control Center) switchboard line for low voltage and currents up to 3150 A, and in compliance with IEC 60439-1 - TTA compliant
More informationWMS SUPPLEMENTARY PROTECTORS
WMS Supplementary Protectors Overview WMS SUPPLEMENTARY PROTECTORS Product Specification The WMS Supplementary Protector is a dual-rated product for both AC and DC supplies, in accordance with UL 1077
More informationRB60 RANGE. Miniature circuit breakers
RB60 RANGE Miniature circuit breakers POWER 2015 RB60 range Miniature circuit breakers Miniature circuit breakers for circuit protection The miniature circuit breakers RB60 are designed for the protection
More informationSECTION SOLID-STATE REDUCED VOLTAGE STARTERS
SECTION 26 29 13.16 PART 1 - GENERAL 1.1 THE REQUIREMENT A. General: The CONTRACTOR shall provide solid-state reduced voltage motor starters, complete and operable, in accordance with the Contract Documents.
More information1.2. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZ Circuit Breaker. UL 489 DIN Rail Miniature Circuit Breakers
.2 WMZ Circuit Breakers Contents Description WMZ Circuit Breaker Standards and Certifications.............. Selection................ Product Selection....................... Accessories...........................
More informationTeSys T Motor Management System
TeSys T Motor Management System Technical Leaflet For Engineer - 1 - Index Index... 2 Chapter 1. Brief Introduction of TeSys T Motor Management System... 3 1.1 The Offer Provides You...3 1.2 Overview of
More information