Technical Publication

Size: px
Start display at page:

Download "Technical Publication"

Transcription

1 Discrete Solution: 12 Fiber Trunk / 4 and 8 Conductor Power Trunk Installation Related Support and Learning Opportunities Offered by the CommScope Infrastructure Academy The insights and expertise contained in this manual represent just one small part of CommScope s global learning initiative. Few industries are evolving as quickly as wireless communications. Every technological innovation impacts what happens in the field. Our customers look to the CommScope Infrastructure Academy to make sure their technicians and installers are well trained, well-prepared, and well-educated to take advantage of opportunities as they evolve. To access a course, go to course #6107 Field Engineering Services (FES) Support services, such as our Field Engineering Services (FES) Group gives CommScope customers access to technical support where and when it is needed the most in the field. The FES team is staffed by an expert team of technicians who, in turn, are supported by some of the brightest and most experienced product line managers. With all of this knowledge and support the FES offers our customers access to hands-on, specialized training classes. Section 1: General Specifications: Fiber and Power Trunk Section 2: Accessories Section 3: Hoisting Considerations Section 4: Power Trunk Installation / Power Trunk Preparation Section 5: Enclosure Wiring Section 6: Fiber Trunk Installation / SiteRise Section 7: Fiber Trunk Installation / Base of Structure Section 8: General Specifications RRU to Direct breakout Tails Section 9: MPO Cassette Mapping / Jacketing Removal for External Grounding Wire Installation...15 Section 10: Breakout Procedure / LC Connector Cleaning Section 11: All in One Cleaners / Inspecting Section 12: Installation Check List / Fiber Troubleshooting Customer Service Center United States and Mexico or International: For the most current, up-to-date information on all our products and product information please visit our ecatalog section at 1

2 General Specifications: Fiber Trunk Cables Cable Type Brand Total Fiber Quantity Shielding Type Fiber Type Construction Type Dimensions Cable Weight Diameter Over Jacket Breakout Length, Fiber, end 1 Breakout Length, Fiber, end 2 Physical Specifications Minimum Bend Radius, loaded Minimum Bend Radius, unloaded Tensile Load, long term, maximum Tensile Load, short term, maximum DFT-12SMOL-xxM HELIAX FiberFeed 12 Corrugated aluminum Single mode fiber Discrete Breakout.82 kg/m.55 lb/ft 23.4 mm 0.92 in 550 mm 22 in 700 mm 28 in 11.1 cm 4.4 in 7.4 cm 2.9 in 334 N 75 lbf 1112 N 250 lbf General Specifications: Power Trunk Cables Cable Type Brand Center Conductor Gauge Conductors, quantity Shielding Type Construction Type DPT-412-APE-xxM HELIAX FiberFeed 12 AWG 4 Corrugated aluminum Discrete Breakout DPT-410-APE-xxM HELIAX FiberFeed 10 AWG 4 Corrugated aluminum Discrete Breakout DPT-408-APE-xxM HELIAX FiberFeed 8 AWG 4 Corrugated aluminum Discrete Breakout Dimensions Cable Weight Diameter Over Jacket.30 kg/m 0.20 lb/ft mm in.39 kg/m 0.26 lb/ft mm in.53 kg/m 0.35 lb/ft mm in Electrical Specifications Conductor dc Resistance Conductor dc Resistance Note 5.43 ohms/km 1.65 ohms/kft Maximum value based on a standard condition of 20 C (68 F) 3.41 ohms/km 1.04 ohms/kft Maximum value based on a standard condition of 20 C (68 F) 2.14 ohms/km 0.65 ohms/kft Maximum value based on a standard condition of 20 C (68 F) Environmental Specifications Operating Temperature -40 C to +80 C (-40 F to +176 F) -40 C to +80 C (-40 F to +176 F) -40 C to +80 C (-40 F to +176 F) 2

3 Accessories Enclosure PART NUMBER FE L-R4 DESCRIPTION Fiber and power cable connection enclosure. Manages two 4-core power trunks 12 AWG up to 8 AWG, one 12 fiber trunk cable and up to 4 hybrid tails. Weatherproof to IP67 Hanger PART NUMBER DESCRIPTION SHK F-10 Hanger and grommet kit for DPT-408-APE cable, kit of 10 SHK F-10 Hanger and grommet kit for DPT-410-APE cable, kit of 10 SHK F-10 Hanger and grommet kit for DPT-412-APE cable, kit of 10 SHC Single plastic clamp and grommet for 408 series power cable, mate to SHK series kits, kit of 12 SHC Single plastic clamp and grommet for 410 series power cable, mate to SHK series kits, kit of 11 SHC Single plastic clamp and grommet for 412 series power cable, mate to SHK series kits, kit of 10 MPO Fiber Management PART NUMBER DESCRIPTION FJ-2SM-LCPC-1M-6 Bend Insensitive Single mode Single mode patch cord with DLC connectors, 1M, pack of 6 FA-MPOC-M-12SMLC MPO cassette, 6 DLC connectors front, 12 fiber MPO connector on rear, 1 per fiber trunk FA-MPOP-1RU MPO cassette panel mount, provides connection stability, holds up to 3 cassettes Other PART NUMBER DESCRIPTION Hoisting grip for power trunk, 408 series power LUGH-38 Hoisting grip, 412 series power cable and fiber trunk cable Hosting grip, 410 series power cable UG B4-T Universal grounding kit GK-SUNV-1M Universal grounding kit, fiber trunk FCCT-MPO MPO interface cleaner FCCT-L DLC & LC interface cleaner FA-FWS-E250 Fiber weather shroud DLCLB-SM-HC3 Power terminal jumper, 2 piece pack 3

4 Hoisting Considerations In general power cable will handle similarly to coaxial cable, and similar installation techniques apply. All cables are individually serialized, be sure to write down the cable serial number for future reference. Prevent the power conductors from undue movement during hoisting by securing with tie ropes every 1 m (3 ft) to the hoisting line. During hoisting ensure that there is a free path and that the cable, and especially the end of the cable so it will not be snagged on tower members or other obstacles. Installation temperature range is -30 C to +70 C (-22 F to +158 F). Minimum cable bend radii can be found on-line in our ecatalog section at Maximum cable tensile load can be found on-line in our ecatalog section at CommScope Lace-Up Hoisting Grip required for power and fiber trunk installations. Hoisting Grip should be anchored to the support structure after the hangers are installed.! Power Cables weigh more than traditional coaxial cables. Be sure to follow proper hoisting and attachment procedures. Hoisting Recommendations Fiber Enclosure Box (D) (D) Grip Location Reminder: Plan grip location by measuring distance (D) from Fiber Enclosure Box to tower support member. 4

5 Tie back ropes 1 M (3 ft) Minimum leader 5.3 M (17 ft) Steel cable or rope hoist line! Required Apply provided Tie Wrap to the base of the hoisting grip before applying tension to the line. Maximum 60 M (200 ft) between hoisting grips Clevis Hoisting grip 5

6 Power Trunk Installation 1 2 After SiteRise is installed hoist power trunk using appropriate hoisting grip. Loop the top of the hoisting grip over the tower structure and shackle together. During SiteRise installation remove fiber reel covering the enclosure box and support out of the way. Complete routing of the power trunk to the enclosure box. SiteRise! DO NOT DROP REEL. Damage to fiber can occur at support hanger. Power trunk Hoisting rope Shackle 6

7 Power Trunk Preparation 3 Prepare power conductor end by removing 0.5 m of jacketing and outer shielding exposing power conductors. Remove.05 m of jacketing from the end for grounding inside of the enclosure..05 m (1.97 in).5 m (19.69 in) Follow steps below for splitting of the cable. a Mark cutback length b Notch Armor using flush cutter in-line with Kevlar strings c Place Rip Cord in Notches' d Pull Rip Cord Parallel to Cable (while supporting breakout) e Stop at Length Marker f Separate Armor 7

8 g Cut Armor Using Side Cutter h Remove Water Blocking Tape NOTE: Step can be expedited by using a sewing seam ripper that can be purchased at local hobby stores Scan to view video Click here for video i Remove Excess Rip Cord j Remove 0.5 m of jacketing from the end of the cable NOTE: remove any remaining adhesive with low grit emery cloth. Seam Ripper Cable Splitter tool Part Number: FA-RCRT-PD Enclosure Wiring 4 Open the enclosure box and wire power cable as required. Black conductors to black terminals, Color conductors to blue terminals. Place ground wire on exposed outer conductor and fasten with clamp. See page 7-8 for specific wire locations. Cable must enter straight in the enclosure box for proper weather sealing of the gland. 8

9 Wiring Diagram / 4 conductor power trunk! Seal the fiber box lid with provided screws (Qty 4) to the torque value range: /-0 Kgf.cm Terminal Blocks: Torque value range: Nm ( inlbs) A B C D A B C D Top Bottom Side view 1 2 Tail Connections A 1 2 B 1 1 D C Top view Top Bottom Side view 1 2 A 3 4 B Trunk Connections 5 6 D C Terrminals jumpers Push or Screw style 4 conductor power trunk Power Trunk 1 Power Trunk 2 Fiber Trunk Fiber Tails D (bottom) Fiber Tails C (top) Fiber Tails A (bottom) Fiber Tails B (top) Dome Nut Torque value range: 6 +/-.5Nm (53 +/- 4 inlbs) 9

10 Wiring Diagram / 2 x 4 conductor and 8 conductor power trunk A B C D A B Qty: 2 four conductor power trunks 8 conductor power trunk Power trunk 1 Power trunk 2 10

11 Fiber Trunk Installation / SiteRise lowering 5 Hanger Fiber trunk Fiber trunk reel Fiber/Power Enclosure box Power trunk After power trunk is wired to the enclosure box prepare the Fiber trunk reel for lowering. 6 7 Hoisting grip Bridal ropes with loop in the middle mm (16 in) Tag line ropes Push a pipe with a hole at each end through the Fiber trunk reel. Install bridal and tag line ropes to pipe. Install and attach hoisting grip to tower before lowering fiber. 11

12 8 Pules Fiber Power Support fiber and power trunks to tower with the maximum hanger spacing of 0.9 m (3 ft) m (4 ft) Hoist line rope Tag line ropes Attached hoisting line and slowly lower reel inside of the tower using the tag lines to control the reel. 12

13 Fiber Trunk Installation / Base of Structure 1 2 Hoist fiber trunk using hoisting grip LUGH-38. Loop the top of the hoisting grip over the tower structure next to pre-installed power cable and shackle to the structure. Complete routing of the fiber trunk to the enclosure box. Shackle Fiber trunk Power Fiber Fiber Power Hoisting rope Support fiber and power trunks to tower with the maximum hanger spacing of 0.9 m (3 ft) m (4 ft) 13

14 General Specifications RRU to Direct breakout Tails In general Hybrid cables will handle similarly to a coaxial cable. The terminated fiber ends however are fragile and must be protection during installation. Leave the packaging around the fiber ends in place until ready to make final connect of the jumper at the RRU or BBU. DO NOT BEND THE FIBER ENDS TIGHTER THAN 30 mm (1.2 in) BEND RADIUS ELSE THERE IS A RISK OF BREAKING THE GLASS FIBERS. Attach the main cable securely to the structure or equipment using hangers to prevent strain on connections from movement in wind or snow/ice conditions. Ensure the DLC fiber connector is seated firmly in RRU. Ensure the weatherproof boots for both fiber and power connections are seated firmly in the RRU. Installation temperature range is -22 F to 158 F (-30 C to 70 C). All fiber tails are individually serialized, for immediate access to test results visit General Specifications: Brand Fiber Type Jacket Color Dimensions Cable Weight Diameter Over Jacket Physical Specifications Minimum Bend Radius, loaded Minimum Bend Radius, unloaded Tensile Load, long term, maximum Tensile Load, short term, maximum HELIAX FiberFeed Bend insensitive single mode fiber (G.657.A2) Black 19.4 kg/m 1.3 lb/ft mm.51 in mm 10.2 in mm 5.1 in 467 N 105 lbf 1557 N 350 lbf Huawei PART NUMBER RFA212-2SH2-xxM RFA212-4SH2-xxM DESCRIPTION 2 SM fiber, top breakout 36cm, two fiber cables with DLC, flush cut power cord. Bottom breakout for junction box 4 SM fiber, top breakout 36cm, four fiber cables with DLC, flush cut power cord. Bottom breakout for junction box Ericsson PART NUMBER RFA212-2S15-xxM RFA212-4S15-xxM DESCRIPTION 2 SM fiber, top breakout universal for RRUs, two fiber cables with DLC, flush cut power cord. Bottom breakout for junction box 4 SM fiber, top breakout universal for RRUs, four fiber cables with DLC, flush cut power cord. Bottom breakout for junction box Nokia PART NUMBER RFA212-2S36-xxM RFA212-4S36-xxM DESCRIPTION 2 SM fiber, top breakout with angle DLC with boots for RRUs FXDB 900Mhz and FXEB 1800 Mhz, Bottom breakout for junction box 4 SM fiber, top breakout with angle DLC with boots for RRUs FXDB 900Mhz and FXEB 1800 Mhz, Bottom breakout for junction box ZTE PART NUMBER RFA212-2S09-xxM RFA212-4S09-xxM DESCRIPTION 2 SM fiber, top breakout 36cm, two fiber cables with DLC, flush cut power cord. Bottom breakout for junction box 4 SM fiber, top breakout 36cm, four fiber cables with DLC, flush cut power cord. Bottom breakout for junction box 14

15 MPO Cassette Mapping RRU 1 RRU 2 Key Up RRU 3 RRU 4 Key Up RRU 5 RRU 6 Key Up Jacketing Removal for external Grounding Wire Installation 1. Score the jacketing 360º 2. For Power trunk measure 2 (51 mm) and repeat - for fiber trunk measure 1/4 (6.35 mm) 3. Identify where the aluminum shielding overlaps, this will feel like a flat spot in the cable 4. With a knife flat on the cable remove a section of jacketing between score marks 5. Lift edge of jacketing with knife tip 6. Grab lifted edge of jacketing with a pair of pliers and roll on the cable 7. With a piece of emery cloth Remove a min 40% coating to expose aluminum for electrical contact Scan to view video Click here for video 15

16 Breakout Procedure After the trunk cable has been installed and you are ready to make the final connection to the OVP box follow these steps for the removal of fiber protection tube. 1 Remove electrical tape from the trunk cable and corrugated protection tube 2 While holding the protection tube straight pull the tube away from cable. 3 After you have pulled the fiber and power conductors into the OVP box remove electrical tape from the trunk cable and remove clear tube for access to all optical connectors. LC Connectors Cleaning Clean exposed connector ferrule by lightly moistening lint-free wipe with fiber optic cleaning solution (or >91% isopropyl alcohol), and by applying medium pressure, first wipe against wet area and then onto dry area to clean potential residue from end face. Clean connector ferrule inside adapter by inserting lightly moistened cleaning stick with fiber optic cleaning solution (or >91% isopropyl alcohol) inside the adapter until contact is made with connector on opposite end. Rotate cleaning stick with medium pressure in one circular motion as it is pulled away from the adapter. Repeat process using dry cleaning stick. Caution: Signal strength will be affected if end and sides of ferrule are not thoroughly cleaned. Discard cleaning sticks after each use. Do not turn cleaning sticks back and forth pressing against connector end face. This may cause scratches if large contamination is present. Always inspect connector end face for contamination after each cleaning. Clean Sides of Ferrule Clean Tip of Ferrule Clean adapter by inserting adapter cleaning stick (or fiber adapter sleeve brush) moistened with fiber optic cleaning solution (or >91% isopropyl alcohol) inside the adapter and gently pull out with twisting motion. Repeat process with a dry cleaning stick. Caution: Do not try to clean adapter with a standard pipe cleaner. The sleeve inner diameter of LC adapters is too small. Do not try to clean the adapter with cleaning stick if a connector is mounted in one side. Discard cleaning sticks after each use. Adapter Brush 16

17 All in One Cleaners Designed for cleaning the ferrule end faces of connectors Open guide cap, insert connector into guide, push the outer shell to start cleaning the connector interface, a "click" sound indicates end of a cleaning process, repeat, close cap immediately after use. Caution: Be careful not to slant the connector while inserting into the Guide cap. Do not overly exert force during insertion as this may cause damage to both the connector and the cleaner. Connector Cap Guide Part Number: FCCT - L (shown) Push Cleaner X2 Part Number FCCT MPO FCCT L Description MPO Connectors DLC & LC Connectors Inspecting There are 3 basic principles that are critical to achieving an efficient fiber optic connection: 1. Perfect Core Alignment 2. Physical Contact 3. Pristine Connector Interface Scan to view video Today s connector design and production techniques have eliminated most of the challenges to achieving core alignment and physical contact. What remains challenging is maintaining a pristine end-face. As a result, CONTAMINATION is the #1 reason for troubleshooting optical networks. Implementing the process of cleaning and inspecting before mating can reduce the time spent troubleshooting, optimize signal performance and prevent damage. Clean Inspect Is It Clean? Clean No Yes Connect! Abrasive particles (i.e. rock dust) can cause permanent damage to the interface. If interface is scratched it cannot be repaired, it would need to be replaced. 17

18 Installation Check List Double check all connections keeping sectors consistent Double check all electrical terminals are tightened Double check all Enclosure compression fittings Proper external grounding of enclosure with 6 AWG (min) to 2 AWG (max) cables Double check all outdoor RRU connections (fiber, power and connectors) are properly seated Properly support all jumpers to prevent strain on fiber during severe weather Cable serial numbers have been documented in the closeout paperwork and a copy has been left on-site Fiber Troubleshooting Clean First! Clean optical end face with appropriate all in one cleaner. Clean all connector end faces Visually inspect end face for residual dirt and damage Avoid migration of contaminations from one connector to another Check continuity by using LED or lazer light source from one end face and look for light from other end to identify any broken fiber (Do not look directly at cable with lazer source) Check end face again for cleanliness before attachment. If needed, clean again Scan QR code to visit Webtrak online for fast, easy access to test data or download the ctrak app from CommScope 1100 CommScope Place SE P.O. Box 339, Hickory, NC (828) (800) Customer Service 24 hours North America: (toll free) Any country: acicustomersupportcenter@commscope.com Notice: CommScope disclaims any liability or responsibility for the results of improper or unsafe installation, inspection, maintenance, or removal practices. Aviso: CommScope no acepta ninguna obligación ni responsabilidad como resultado de prácticas incorrectas o peligrosas de instalación, inspección, mantenimiento o retiro. Avis : CommScope décline toute responsabilité pour les conséquences de procédures d installation, d inspection, d entretien ou de retrait incorrectes ou dangereuses. Hinweis: CommScope lehnt jede Haftung oder Verantwortung für Schäden ab, die aufgrund unsachgemäßer Installation, Überprüfung, Wartung oder Demontage auftreten. Atenção: A CommScope abdica do direito de toda responsabilidade pelos resultados de práticas inadequadas e sem segurança de instalação, inspeção, manutenção ou remoção. Avvertenza: CommScope declina eventuali responsabilità derivanti dell esecuzione di procedure di installazione, ispezione, manutenzione e smontaggio improprie o poco sicure CommScope 18

Technical Publication

Technical Publication Installation Guidelines HELIAX FiberFeed Direct Solution: Direct Connect Bird Resistant Solution Related Support and Learning Opportunities Offered by the CommScope Infrastructure Academy The insights

More information

Technical Publication

Technical Publication Installation Guidelines HELIAX FiberFeed Solutions Hybrid Cables: HFT1206-2SV2 Low Inductance HFT06-8SV2 Low Inductance HFT10/12 Jumpers Related Support and Learning Opportunities Offered by the CommScope

More information

Technical Publication

Technical Publication Installation Guidelines HELIAX FiberFeed 6 and 12 RRU Solution: Pendant Configuration Related Support and Learning Opportunities Offered by the CommScope Infrastructure Academy The insights and expertise

More information

Pre-Testing and Configuring of. RET Antenna Systems. Prior to Installation. Overview

Pre-Testing and Configuring of. RET Antenna Systems. Prior to Installation. Overview Pre-Testing and Configuring of RET Antenna Systems Prior to Installation Overview Bulletin 653260 Revision B July 2014 CommScope Customer Service 24 hours 1100 CommScope Place SE P.O. Box 339, Hickory,

More information

Product Classification. General Specifications. Construction Materials. Dimensions. Environmental Specifications. General Specifications

Product Classification. General Specifications. Construction Materials. Dimensions. Environmental Specifications. General Specifications Product Classification Portfolio FD2606-24S55-250250 HELIAX FiberFeed Pendant, 2.0, 3 x 12: Six 6 AWG conductors, 24 single mode fibers. Top breakout: 6 HQLC connector outputs. Bottom breakout: blunt cut

More information

NASDAQ: TESS. Verizon Wireless. Commscope Hybrid BOM

NASDAQ: TESS. Verizon Wireless. Commscope Hybrid BOM NASDAQ: TESS Verizon Wireless Commscope Hybrid BOM VZW HELIAX FiberFeed Trunk Cables FiberFeed trunk cable assemblies are factory constructed specifically for the devices listed in the Commscope guide

More information

MASTERLINE Ultimate Hybrid High Voltage 4/12 (MLUH HV 4/12) blunt cut at BTS side

MASTERLINE Ultimate Hybrid High Voltage 4/12 (MLUH HV 4/12) blunt cut at BTS side INSTALLATION MANUAL HUBER+SUHNER AG Fiber Optics MASTERLINE Ultimate Hybrid High Voltage 4/12 (MLU HV 4/12) blunt cut at BTS side DOC-0000803885 Rev A June 18, 2018 Page 1 of 12 (MLUH HV 4/12) blunt cut

More information

Crimplok ST* and SC Non-Adhesive Fiber Optic Single & Multi-mode Connectors

Crimplok ST* and SC Non-Adhesive Fiber Optic Single & Multi-mode Connectors Crimplok ST* and SC Non-Adhesive Fiber Optic Single & Multi-mode Connectors Instructions July 2002 78-8073-7660-9-F 1 Contents 1.0 Warnings and Recommendations... 3 2.0 Tool Kit Contents... 4 3.0 Termination...

More information

FiberExpress Brilliance Connectors

FiberExpress Brilliance Connectors FiberExpress Brilliance Connectors Installation Guide PX105234 Table of Contents Section A - What s New and What You Need to Know 02 Section B - Components and Features 04 Section C - Fiber Preparation

More information

WEB Revision T, May 2016 CommScope Actuators

WEB Revision T, May 2016 CommScope Actuators Revision T, May 2016 CommScope Actuators ATM200-002, ATM200-A20, E-ATM300 This bulletin covers installation procedures for our CommScope line of actuators. Please refer to system configuration diagrams

More information

Cable assembly types. L tot. Total length* L tot end-to-end total (min. 0.5 except receptacles)

Cable assembly types. L tot. Total length* L tot end-to-end total (min. 0.5 except receptacles) CABLE ASSEMBLY TYPES Quantity - Please use one request form per cable assembly type End A Cable assembly types End B Patch cord Receptacle Gas tight receptacle L b Breakout L b Single Fiber Drawings are

More information

Outdoor PTZ. Mounting on the Ceiling Using Pendant Mount. Installation Guide. For Models: I93, I94, I95, I96, KCM /12/03

Outdoor PTZ. Mounting on the Ceiling Using Pendant Mount. Installation Guide. For Models: I93, I94, I95, I96, KCM /12/03 Outdoor PTZ Mounting on the Ceiling Using Pendant Mount For Models: I93, I94, I95, I96, KCM-8211 2013/12/03 Table of Contents Mounting Solutions... 3 Straight Tube Installation Procedures... 4 Step 1:

More information

TECHKNOW, INC. Kiosk Order Confirmation System INSTALLATION MANUAL. Revision Date: July 11, 2012 Part # Version 3.2

TECHKNOW, INC. Kiosk Order Confirmation System INSTALLATION MANUAL. Revision Date: July 11, 2012 Part # Version 3.2 document Page 1 of 18 TECHKNOW, INC Kiosk Order Confirmation System INSTALLATION MANUAL Revision Date: July 11, 2012 Part # Version 3.2 Techknow, Inc. 393 Mayfield Road Duncan, SC 29334 www.gotechknow.com

More information

M204SMB Surface Mount Box Instructions

M204SMB Surface Mount Box Instructions Instruction Sheet 860337070 Issue 7, June 2013 M204SMB Surface Mount Box Instructions General The CommScope M204SMB surface mount box (SMB) is designed for interior surface-mounted applications and can

More information

Optical Fiber Assemblies

Optical Fiber Assemblies Optical Fiber Assemblies Installation and Operation Instructions Overview Ocean Optics offers an extensive line of standard and premium grade optical fibers and accessories including patch cords, bifurcated

More information

OPERATION MANUAL SERIES BORESCOPES INSTRUMENT TECHNOLOGY, INC. POB 381, Westfield, MA Airport Road, Westfield, MA 01085

OPERATION MANUAL SERIES BORESCOPES INSTRUMENT TECHNOLOGY, INC. POB 381, Westfield, MA Airport Road, Westfield, MA 01085 OPERATION MANUAL SERIES 123000 BORESCOPES INSTRUMENT TECHNOLOGY, INC. POB 381, Westfield, MA 01086 33 Airport Road, Westfield, MA 01085 Tel: (413) 562-3606 Fax: (413) 568-9809 Email: iti@scopes.com www.scopes.com

More information

RCC45 ➁ Overview / /

RCC45 ➁ Overview / / RCC45 ➁ Overview 010.2936 More future and modularity Integration of POF and power Guaranteed modularity Long-term investment protection Flexible cabling solution Fast and convenient installation 1 010.2721

More information

ONE SD-LAN Wall Mount Splitter Housing (1LAN-SPLT C)

ONE SD-LAN Wall Mount Splitter Housing (1LAN-SPLT C) CMA-477-AEN 1 General Figure 1 STANDARD RECOMMENDED PROCEDURE 000-000-AEN ISSUE 1 MARCH 2018 I Page 1 2 Carton Contents Installation instruction Wall Mount Splitter housing Cable installation hardware

More information

G12/G12x USER S MANUAL

G12/G12x USER S MANUAL G12/G12x USER S MANUAL TABLE OF CONTENTS SECTION 1 SLIDE CONFIGURATION SECTION 2 SLIDE CONFIGURATION ACCESSORIES SECTION 3 TABLETOP CONFIGURATION SECTION 4 TABLETOP CONFIGURATION ACCESSORIES SECTION 5

More information

The Eye Com 7000 Dual Page Reader Operating and Maintenance Instructions

The Eye Com 7000 Dual Page Reader Operating and Maintenance Instructions A MEDIA INDEPENDENT DOCUMENT MANAGEMENT COMPANY EYE COMMUNICATION SYSTEMS, INC. 455 E. Industrial Drive P.O. Box 620 Hartland, WI 53029 USA (262) 367-1360 or (800) 558-2153 Fax: (262) 367-1362 www.eyecom.com

More information

Pre-polished Connector Insertion Loss and Termination Yield. Achieving High Termination Yields And Low Insertion Loss Values

Pre-polished Connector Insertion Loss and Termination Yield. Achieving High Termination Yields And Low Insertion Loss Values Pre-polished Connector Insertion Loss and Termination Yield Achieving High Termination Yields And Low Insertion Loss Values White Paper 1/2004 Executive Summary Pre-polished connectors offer a quick and

More information

Mini Wall-mount Building Terminal (WBM)

Mini Wall-mount Building Terminal (WBM) Corning Cable Systems Standard Recommended Procedure (SRP) 003-516 Issue 2, October 2004 Page 1 of 8 Contents Figure 1 WBM 1. General...1 2. Description...2 3. Precautions...2 4. Tools and Materials...3

More information

SYSTIMAX 360 ipatch 96F LC Upgrade Kit

SYSTIMAX 360 ipatch 96F LC Upgrade Kit Issue 5, July 2016 SYSTIMAX 360 ipatch 96F LC Upgrade Kit General ipatch Upgrade Kits adapt previously installed SYSTIMAX InstaPATCH LC and HD shelves to ipatch fiber shelves to enable ipatch system high

More information

OPERATION MANUAL SERIES MICRO BORESCOPES INSTRUMENT TECHNOLOGY, INC. POB 381, Westfield, MA Airport Road, Westfield, MA 01085

OPERATION MANUAL SERIES MICRO BORESCOPES INSTRUMENT TECHNOLOGY, INC. POB 381, Westfield, MA Airport Road, Westfield, MA 01085 OPERATION MANUAL SERIES 124000 MICRO BORESCOPES INSTRUMENT TECHNOLOGY, INC. POB 381, Westfield, MA 01086 33 Airport Road, Westfield, MA 01085 Tel: (413) 562-3606 Fax: (413) 568-9809 Email: iti@scopes.com

More information

Gateway Profile 4 service guide

Gateway Profile 4 service guide Gateway Profile 4 service guide Customizing Troubleshooting Contents Replacing Components in Your Gateway Profile 4.................. 1 About this guide.....................................................

More information

CSS1 Contractor Series Light Sources and CSM1 Contractor Series Optical Power Meters User s Guide

CSS1 Contractor Series Light Sources and CSM1 Contractor Series Optical Power Meters User s Guide CSS1 Contractor Series Light Sources and CSM1 Contractor Series Optical Power Meters User s Guide www.aflglobal.com or (800) 321-5298, (603) 528-7780 Limited Warranty All NOYES test equipment products

More information

OLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide

OLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide OLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide 2004-2009, AFL Telecommunications, all rights reserved. COM4-00-1001 Revision E, 2009-06-16 Specifications

More information

Keysight M8000 Series BER Test Solutions

Keysight M8000 Series BER Test Solutions Keysight M8000 Series BER Test Solutions J-BERT M8020A High-Performance BERT M8030A Multi-Channel BERT M8040A High-Performance BERT M8041A, M8051A, M8061A, M8062A, M8045A, M8046A & M8057A Tips for Preventing

More information

MVPplus Quick Reference Guide

MVPplus Quick Reference Guide MVPplus Quick Reference Guide Use this guide to operate your printer on a daily basis. For more detailed information, refer to the User Guide. Contents External View...........................................................

More information

Instruction Manual R&M Connectors. R&M Fiber Optic Components. System security for future requirements. Version 2.4

Instruction Manual R&M Connectors. R&M Fiber Optic Components. System security for future requirements. Version 2.4 Instruction Manual R&M Connectors R&M Fiber Optic Components System security for future requirements Version 2.4 1/13 R&M Fiber Optic Components... 1 System security for future requirements... 1 1. Foreword...

More information

3M Fibrlok II Angle Fiber Splice 2529-AS 3M Fibrlok 250 µm Angle Fiber Splice 2540-AS

3M Fibrlok II Angle Fiber Splice 2529-AS 3M Fibrlok 250 µm Angle Fiber Splice 2540-AS 3M Fibrlok II Angle Fiber Splice 2529-AS 3M Fibrlok 250 µm Angle Fiber Splice 2540-AS Instructions January 2009 78-8140-1580-2-C Contents 1.0 Summary...3 2.0 Splicing Set-up...4 3.0 Fiber Preparation...4

More information

TABLE OF CONTENTS INTRODUCTION 2 BOTS 3 CABLES BULKHEADS 15 MOUNTING BRACKETS 19 ACCESSORIES 23 CUSTOM PROJECTS 25. Cable Types 10.

TABLE OF CONTENTS INTRODUCTION 2 BOTS 3 CABLES BULKHEADS 15 MOUNTING BRACKETS 19 ACCESSORIES 23 CUSTOM PROJECTS 25. Cable Types 10. CATALOGUE TABLE OF CONTENTS INTRODUCTION 2 BOTS 3 CABLES Cable Types 10 Cable Adaptors 13 BULKHEADS 15 MOUNTING BRACKETS 19 ACCESSORIES 23 CUSTOM PROJECTS 25 With fibre optics becoming the absolute foundation

More information

SignBOX II. Retrofit Guide for (X)WS201 and (X)WD201

SignBOX II. Retrofit Guide for (X)WS201 and (X)WD201 Scope: This procedure is designed to aid in the installation of SloanLED s SignBOX II illumination product and power supply products. Skilled tradespeople familiar with general construction, electrical

More information

UniCam Connector Installation Tool Kits

UniCam Connector Installation Tool Kits features and benefits Terminates single-mode and multimode fibers Convenient carrying case Continuity test set (CTS) Visual feedback signal (TKT-UNICAM-PFC) Pretium Cleaver (FBC-05) SPECIFICATION SHEET

More information

Halo-5 Microdrive. Users Manual. Microdrive used for manually driving tetrodes for electrophysiology recordings

Halo-5 Microdrive. Users Manual. Microdrive used for manually driving tetrodes for electrophysiology recordings Halo-5 Microdrive Users Manual Microdrive used for manually driving tetrodes for electrophysiology recordings Neuralynx, Inc. 105 Commercial Drive, Bozeman, MT 59715 Phone 406.585.4542 Fax 866.585.1743

More information

BreezeMAX Wi² and BreezeACCESS Wi² Quick Installation Guide

BreezeMAX Wi² and BreezeACCESS Wi² Quick Installation Guide This Quick Installation Guide is intended for experienced installers. For more information refer to the relevant sections in the BreezeMAX Wi² and BreezeACCESS Wi² System Manual. Wi² Package Content Check

More information

TABLE OF CONTENTS SECTION 1 TABLETOP CONFIGURATION SECTION 2 TABLETOP CONFIGURATION ACCESSORIES SECTION 3 SLIDE CONFIGURATION

TABLE OF CONTENTS SECTION 1 TABLETOP CONFIGURATION SECTION 2 TABLETOP CONFIGURATION ACCESSORIES SECTION 3 SLIDE CONFIGURATION S6 USER S MANUAL TABLE OF CONTENTS SECTION 1 TABLETOP CONFIGURATION SECTION 2 TABLETOP CONFIGURATION ACCESSORIES SECTION 3 SLIDE CONFIGURATION SECTION 4 SLIDE CONFIGURATION ACCESSORIES SECTION 5 RACK MOUNT

More information

Construction Materials. Dimensions. Environmental Specifications. General Specifications. Mechanical Specifications

Construction Materials. Dimensions. Environmental Specifications. General Specifications. Mechanical Specifications 760184002 TeraSPEED LC to SC, Fiber Patch Cord, 1.6 mm Simplex, Plenum Total Fibers, quantity 1 TeraSPEED, zero water peak singlemode fiber (G.652.D, G.657.A1 or G.652.D, G.657.A1 OS2) Dimensions Cord

More information

Product Classification. Construction Materials. Dimensions. Environmental Specifications. General Specifications. Mechanical Specifications

Product Classification. Construction Materials. Dimensions. Environmental Specifications. General Specifications. Mechanical Specifications 760200527 TeraSPEED FC APC to Unconnectorized, Fiber Patch Cord, 1.6 mm Simplex, Plenum Product Portfolio Brand Product Type CommScope TeraSPEED Fiber test patch cord Regional Availability Asia Australia/New

More information

Upgrade Instructions. P/N Revision A. October Printer Terminal Holder * *

Upgrade Instructions. P/N Revision A. October Printer Terminal Holder * * Upgrade Instructions P/N 96-08-0 Revision A October 000 480 Printer Terminal Holder P/N 96-08-0 Revision A *96080* Instructions This terminal holder connects the INTERMEC R 600 Series and 700 Series Computers

More information

Wall Mounted Building Entrance Enclosure Instructions

Wall Mounted Building Entrance Enclosure Instructions Instruction Sheet 860383587 Issue 8, February 2014 Wall Mounted Building Entrance Enclosure Instructions General The CommScope wall mounted building entrance enclosures are designed to enable field and

More information

LARGE S URGE-PROTECTOR S HELTER

LARGE S URGE-PROTECTOR S HELTER LARGE S URGE-PROTECTOR S HELTER The weather-resistant Large Surge-Protector Shelter (simply referred to as the shelter in this manual) provides protection from the elements for Surge Protectors (not included)

More information

Compact Series Wallmount Enclosures

Compact Series Wallmount Enclosures Compact Series Page 1 of 5 Overview ARIA s Compact Series are small wallmount enclosures that features patch and splice capabilities. The enclosures also support 12 fiber MPO to LC connector plug and play

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS Wired Remote Controller 7 Day Programmable Ductless Systems KSACN0401AAA (High Wall Models) KSACN0501AAA (Ducted/Cassette Models) INSTALLATION INSTRUCTIONS NOTE: Read the entire instruction manual before

More information

Mounting on the Ceiling Using Flush Mount (Face Down)

Mounting on the Ceiling Using Flush Mount (Face Down) Mounting on the Ceiling Using Flush Mount (Face Down) Installation Guide 2014/02/14 Table of Contents Safety Information... 3 Installation Procedures... 5 Step 1: Drill a Hole on the Ceiling... 5 Step

More information

Richter Optica. Instructions for Model: S-2 Dual Power Stereo Microscope

Richter Optica. Instructions for Model: S-2 Dual Power Stereo Microscope Richter Optica 6122 Innovation Way Carlsbad, California 92009 (800) 942-0528 US TOLL FREE (760) 438-0528 INTERNATIONAL Instructions for Model: S-2 Dual Power Stereo Microscope Eyepieces Post Diopter Adjustment

More information

with Fiber Management Bar

with Fiber Management Bar Issue 1, June 2014 SYSTIMAX 1100A Angled Fiber Termination Panel with Fiber Management Bar General The SYSTIMAX 1100A angled fiber termination panel is a 19 wide x 1.75 high (483mm x 44mm) 1U panel designed

More information

Samsung Galaxy S10 Front-Facing Camera

Samsung Galaxy S10 Front-Facing Camera Samsung Galaxy S10 Front-Facing Camera Replacement This guide shows how to remove and replace the front-facing camera in the Galaxy S10. Written By: Arthur Shi ifixit CC BY-NC-SA www.ifixit.com Page 1

More information

Prisma II Chassis 56-Port Upgrade Technical Bulletin

Prisma II Chassis 56-Port Upgrade Technical Bulletin Prisma II Chassis 56-Port Upgrade Technical Bulletin Overview Audience Introduction This technical bulletin applies to all cable system operators and technicians who use the Prisma II Chassis configured

More information

MONARCH 9416 XL QUICK REFERENCE

MONARCH 9416 XL QUICK REFERENCE MONARCH 9416 XL QUICK REFERENCE This Quick Reference contains ribbon loading, supply loading, and general care, maintenance, and troubleshooting procedures for the 9416 XL Thermal Direct and 9416 XL Thermal

More information

Constructing a Low-Cost Mobile Eye Tracker

Constructing a Low-Cost Mobile Eye Tracker ==== Constructing a Low-Cost Mobile Eye Tracker ==== Section 1: Introduction This is a detailed set of instructions on how to build a low-cost mobile eye-tracking system from off-the-shelf components.

More information

Spec Sheet. OmniReach FTTX Solutions DLX Fiber Optic Connector

Spec Sheet. OmniReach FTTX Solutions DLX Fiber Optic Connector ADC s is a Next Generation hardened fiber optic connector designed to provide a cost-effective solution for connecting Outside Plant (OSP) fiber networks. The DLX connector is a miniature hardened connector

More information

imac Intel 21.5" EMC 2389 Stand Replacement

imac Intel 21.5 EMC 2389 Stand Replacement imac Intel 21.5" EMC 2389 Stand Replacement Replace a broken or cosmetically unappealing stand on the imac 2389 21.5 Written By: Aaron Cooke ifixit CC BY-NC-SA www.ifixit.com Page 1 of 30 INTRODUCTION

More information

User Manual. Revision B

User Manual. Revision B User Manual TM Revision B Copyright 2014 Electronic Theatre Controls, Inc. All Rights reserved. Product information and specifications subject to change. Part Number: 7063M1220 Rev B Released: 2014-07

More information

imac Intel 21.5" EMC 2428 SSD Dual Drive

imac Intel 21.5 EMC 2428 SSD Dual Drive imac Intel 21.5" EMC 2428 SSD Dual Drive Installation Install an SSD in your imac Intel 21.5" EMC 2428. Written By: Dozuki System 2017 guides.crucial.com Page 1 of 33 INTRODUCTION Use this guide to install

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS AFL TITAN RTD Multiport Terminal AFL TRIDENT Hardened Drop TABLE OF CONTENTS GENERAL... 2 SPECIFICATIONS... 2 PACKAGE CONTENTS... 3 REQUIRED TOOLS... 3 ADD-ON COMPONENTS... 3 TERMINAL MOUNTING STRAND...

More information

imac Intel 27" EMC 2639 Hard Drive

imac Intel 27 EMC 2639 Hard Drive imac Intel 27" EMC 2639 Hard Drive Replacement Replace the Hard Drive in your imac Intel 27" EMC 2639. Written By: Walter Galan ifixit CC BY-NC-SA www.ifixit.com Page 1 of 26 INTRODUCTION Replacing the

More information

imac Intel 27" EMC 2546 Adhesive Strips

imac Intel 27 EMC 2546 Adhesive Strips imac Intel 27" EMC 2546 Adhesive Strips Replacement Reattach your display with a set of adhesive foam strips. Written By: Andrew Optimus Goldberg ifixit CC BY-NC-SA www.ifixit.com Page 1 of 18 INTRODUCTION

More information

imac Intel 27" Retina 5K Display CPU Replacement

imac Intel 27 Retina 5K Display CPU Replacement imac Intel 27" Retina 5K Display CPU Replacement Replace or upgrade the CPU in your imac Intel 27" Retina 5K Display. Written By: Sam Lionheart ifixit CC BY-NC-SA www.ifixit.com Page 1 of 36 INTRODUCTION

More information

Star Trac Fitness E-ST 5090 Stepper. Install Guide

Star Trac Fitness E-ST 5090 Stepper. Install Guide Star Trac Fitness E-ST 5090 Stepper Install Guide STAR TRAC E-ST STEPPER Install Guide E-ST 5090 E Series Stepper ASSEMBLY AND SETUP The following parts are included with the base STAR TRAC E-ST STEPPER:

More information

Cabling Solutions Data Center & Local Area Networks

Cabling Solutions Data Center & Local Area Networks Cabling Solutions Data Center & Local Area Networks R&M About us. «R&M is a leading provider of cabling solutions for high quality communication networks.» R&M (Reichle & De-Massari AG) has developed and

More information

Navigator II INstallatIoN MaNUal For static and PaN/tIlt configurations

Navigator II INstallatIoN MaNUal For static and PaN/tIlt configurations Navigator II Installation MANUAL For Static and Pan/Tilt Configurations Document Number: 432-0001-00-12, rev 100 FLIR Systems, Inc., 2008. All rights reserved worldwide. No parts of this manual, in whole

More information

Copyright Black Box Corporation. All rights reserved.

Copyright Black Box Corporation. All rights reserved. Copyright 1999. Black Box Corporation. All rights reserved. 1000 Park Drive Lawrence, PA 15055-1018 724-746-5500 Fax 724-746-0746 JUNE 1999 FT990A FT991 FT992 FT993 Fiber Optic Inspection Scope CUSTOMER

More information

Written By: Sam Lionheart

Written By: Sam Lionheart iphone 6 Front Panel Replacement Replace the bare front panel of an iphone 6. Written By: Sam Lionheart ifixit CC BY-NC-SA www.ifixit.com Page 1 of 27 INTRODUCTION For an easier repair, use our fix kit

More information

Clean packaging Class M3.5 Standard packaging Class M5.5. The U type is recommended when changing tubing sizes. Packaging

Clean packaging Class M3.5 Standard packaging Class M5.5. The U type is recommended when changing tubing sizes. Packaging eries LQ Options Panel mounting nut LQ U Applicable fitting LQN P Applicable fitting LQ LQ Application For LQ For LQ insert bushing Clean packaging M. tandard packaging M. The U type is recommended when

More information

ENC 125 T/E REFERENCE MANUAL. Acu-Rite Companies Inc.

ENC 125 T/E REFERENCE MANUAL. Acu-Rite Companies Inc. ENC 125 T/E REFERENCE MANUAL Acu-Rite Companies Inc. ENC 125 T/E Page Introduction... 2 Mounting Preparation... 3 Mounting Information... 4 Encoder Dimensions - ENC 125 T (top mount)... 5 Encoder Dimensions

More information

Zebra XiII-Series Printer Quick Reference Guide

Zebra XiII-Series Printer Quick Reference Guide Zebra XiII-Series Printer Quick Reference Guide Contents Media and Ribbon Loading...67 Media Loading...67 Ribbon Loading...70 Operator Controls...72 Front Panel Keys...72 Front Panel Lights...72 Calibration...74

More information

Miniature outside plant plug-and-play solutions. White paper

Miniature outside plant plug-and-play solutions. White paper outside plant plug-and-play solutions White paper A new class of miniature fiber optic connectors provides a plug and play interface between fiber optic cables and consumers in FTTP applications. These

More information

Fiber Optic Prism Switch USER S MANUAL

Fiber Optic Prism Switch USER S MANUAL Fiber Optic Prism Switch USER S MANUAL Warranty Newport Corporation warrants this product to be free from defects in material and workmanship for a period of one year from the date of shipment. If found

More information

OPTICAL CONNECTOR CONTAMINATION

OPTICAL CONNECTOR CONTAMINATION OPTICAL CONNECTOR CONTAMINATION 6 What do the standards say? The test procedures specified by 568-C require tools and procedures for ensuring connector quality. End faces on cords and trunks shall be in

More information

Product Data Sheet. SC Thead-Lock Connector Assembly Instructions. Page 1 of 5 QUALITY FIBER COMPONENTS, EQUIPMENT, & SUPPLIES

Product Data Sheet. SC Thead-Lock Connector Assembly Instructions. Page 1 of 5 QUALITY FIBER COMPONENTS, EQUIPMENT, & SUPPLIES Page 1 of 5 SC Thead-Lock Connector Assembly Instructions Page 2 of 5 A. 2.0mm, 2.5mm & 3.0mm JACKETED CABLE 1. Place jacketed fiber protective boot on cable and slide back. (Figure 1) NOTE: To help avoid

More information

3 Maintenance. Chapter contents

3 Maintenance. Chapter contents 3 Maintenance Chapter contents Life expectancies of consumables..................... 40 User-replaceable parts.............................. 40 Replacing the printer pickup roller................ 41 Replacing

More information

Schneider Automation Modbus Plus Network Installing Clustered Node Devices Publication: 890 USE Rev. 1.0 Part Number:

Schneider Automation Modbus Plus Network Installing Clustered Node Devices Publication: 890 USE Rev. 1.0 Part Number: Schneider Automation Modbus Plus Network Installing Clustered Node Devices Publication: 890 USE 53 00 Rev..0 Part Number: 3000939 Modbus Plus devices must be installed as specified in a network layout

More information

Ag Leader Technology. DirectCommand Installation RoGator Model Years

Ag Leader Technology. DirectCommand Installation RoGator Model Years Note: Indented items indicate parts included in an assembly listed above Part Name/Description Part Number Quantity Direct Command Kit 4100550 1 Dual Lock 2000052-9 1 Dual Lock 2000053-9 1 Hardware Kit

More information

HD Flex Zero RU Cassette Holder and Bracket

HD Flex Zero RU Cassette Holder and Bracket HD Flex Zero RU Cassette Holder and Bracket Part Numbers: FLEX-0RUBR**, FLEX0RUCH** Panduit Corp. 2016 INSTALLATION INSTRUCTIONS The Zero RU Cassette Holder and Bracket are designed to mount on the side

More information

Outdoor FDH Termination Pole-Mount Cabinet With Universal Splitter Chassis User Manual

Outdoor FDH Termination Pole-Mount Cabinet With Universal Splitter Chassis User Manual Outdoor FDH 3000 288 Termination Pole-Mount Cabinet With Universal Splitter Chassis User Manual ADCP-96-184 Issue 1 8/2014 25555-A 300100104431 Rev A Preface COPYRIGHT 2014, Tyco Electronics Corporation

More information

C-pan arm USERS INSTRUCTIONS

C-pan arm USERS INSTRUCTIONS C-pan arm USERS INSTRUCTIONS Designed 1 of 12 and made in Denmark Thanks for purchasing a 9.Solutions product. With great passion, we design our products to be as versatile as possible. We hope that our

More information

FO Trunk Cable. FO Trunk Cable

FO Trunk Cable. FO Trunk Cable 5 FO Trunk Cable www.easylan.de FO Trunk Cable u 2 to 144 fibers u Various cable types u PC and APC polish u Tuned connectors u Gradations as desired u Up to IP67 u etc. 104 05 FO Trunk Cable Contents

More information

INSTALLATION MANUAL. ST-BTWD650IR2812 B or W Weatherproof Day/Night Infrared Color Camera

INSTALLATION MANUAL. ST-BTWD650IR2812 B or W Weatherproof Day/Night Infrared Color Camera INSTALLATION MANUAL ST-BTWD650IR2812 B or W Weatherproof Day/Night Infrared Color Camera PACKAGE CONTENTS This package contains: One ST-BTWD650IR2812 camera with Black or White housing One extension tube

More information

2. REFERENCE DOCUMENTS 90R0047 Safety Guidelines for Handling Equipment 90F0112 Safe Handling and Cleaning Procedures for Serviceable ZOLL Product

2. REFERENCE DOCUMENTS 90R0047 Safety Guidelines for Handling Equipment 90F0112 Safe Handling and Cleaning Procedures for Serviceable ZOLL Product ZOLL Document Number: 90R0008 Page 3 of 11 1. INTRODUCTION This document defines the handling and cleaning process for WCD LifeVest System Hardware returned from the field. This document also defines acceptable

More information

Sheath Removal of 3456-Fiber RocketRibbon Extreme-Density Cable

Sheath Removal of 3456-Fiber RocketRibbon Extreme-Density Cable Sheath Removal of 3456-Fiber RocketRibbon Extreme-Density Cable P/N 004-279-AEN Issue 1 related literature Search www.corning.com/opcomm. Click on Resources/Standard Recommended Procedures. 004-098 Instruction,

More information

SENC 150 REFERENCE MANUAL

SENC 150 REFERENCE MANUAL SENC 50 REFERENCE MANUAL SENC 50 Table of Contents / Warnings Page Introduction / Supplied items... 4 2 Preparing the mounting / Mounting information... 5 3 Encoder dimensions... 8 4 Backup spar dimensions...

More information

Polarization Microscope. Omano OM349P Series. User Guide

Polarization Microscope. Omano OM349P Series. User Guide Polarization Microscope Omano OM349P Series User Guide Table of Contents Getting Started... 3 Components... 3 Technical Specifications... 5 Setup Instructions... 6 Basic Operation... 7 Changing the Light

More information

Design and Manufacture of Video Pipeline Inspection Systems A Full Service Company

Design and Manufacture of Video Pipeline Inspection Systems A Full Service Company Design and Manufacture of Video Pipeline Inspection Systems A Full Service Company www.rstechserv.com Omni Star LED Pan and Tilt Zoom Color Camera Modell 10-1660 INSTALLATION MANUAL Made in USA IMPORTANT

More information

PEREGRINE SERIES RETROFIT INSTALLATION GUIDE

PEREGRINE SERIES RETROFIT INSTALLATION GUIDE 06.05.17 HanleyLED H100W-PPS524V Spec Sheet SOLUTIONS THAT MAKE SENSE PEREGRINE SERIES RETROFIT INSTALLATION GUIDE Light Up New Markets Your Local Distributor: Grimco US www.grimco.com 800.542.9941 Canada

More information

Transparent Covers for Rail-Mounted Terminal Blocks, Usable with Lead Seals Description and Handling

Transparent Covers for Rail-Mounted Terminal Blocks, Usable with Lead Seals Description and Handling Transparent Covers for Rail-Mounted Terminal Blocks, Usable with Lead Seals Description and Handling 572 Assembly Application Snapping a cover carrier onto the carrier rail. Application examples: cover

More information

Mini-DVI-WP Series WALL PLATE MINIATURE MULTIMODE FIBER OPTIC DVI TRANSMISSION SYSTEM

Mini-DVI-WP Series WALL PLATE MINIATURE MULTIMODE FIBER OPTIC DVI TRANSMISSION SYSTEM Mini-DVI-WP Series WALL PLATE MINIATURE MULTIMODE FIBER OPTIC DVI TRANSMISSION SYSTEM BCI reserves the right to make changes to the products described herein without prior notice or consent. No liability

More information

The world is going through a data explosion and this is largely being driven by the mobile revolution.

The world is going through a data explosion and this is largely being driven by the mobile revolution. The world is going through a data explosion and this is largely being driven by the mobile revolution. Samsung Interconnectivity Solution for Remote Radio Head Samsung s Hybrid Connector Cabling (HCC)

More information

Ultra Low Loss (ULL) LazrSPEED 550 OM4 LC to LC, Fiber Patch Cord, 1.6 mm Duplex, LSZH

Ultra Low Loss (ULL) LazrSPEED 550 OM4 LC to LC, Fiber Patch Cord, 1.6 mm Duplex, LSZH UFXLCLC42 Ultra Low Loss (ULL) LazrSPEED 550 OM4 LC to LC, Fiber Patch Cord, 1.6 mm Duplex, LSZH Product Classification Portfolio SYSTIMAX Brand LazrSPEED SYSTIMAX ULL Product Type Fiber patch cord, duplex

More information

Polymer Coated Fiber Cable (PCF)

Polymer Coated Fiber Cable (PCF) Polymer Coated Fiber Cable (PCF) Panduit has introduced a Polymer Coated Fiber (PCF) to their fiber cable offering available in 50µm and 62.5µm core diameters. Along with this cable having a stronger durability

More information

MCH WIRE HARNESS WITH QUICK DISCONNECT REPLACEMENT Initial Release 1/31/2013

MCH WIRE HARNESS WITH QUICK DISCONNECT REPLACEMENT Initial Release 1/31/2013 1. Table of Contents 1. Table of Contents Page 1 2. Remove Failed MCH-103.2 Page 1 3. Install MCH-103.2 to MCH-102NW Page 2 4. Install NC3FX-HD to MCH-103.2 Page 3 5. Install MCH-103.2 Battery Terminal

More information

VFS 2 Video Fiber Scope User s Guide. Test & Inspection

VFS 2 Video Fiber Scope User s Guide. Test & Inspection VFS 2 Video Fiber Scope User s Guide Test & Inspection VFS 2 Video Fiber Scope User s Guide Test & Inspection 2004-2010, AFL Telecommunications, all rights reserved. VFS2-00-1000 Revision B 2010-07-30

More information

Pretium EDGE HD Solutions A LANscape Pretium Solutions Product

Pretium EDGE HD Solutions A LANscape Pretium Solutions Product Pretium EDGE HD Solutions for Enterprise Data Centers and Storage Area Networks Corning Pretium EDGE HD solutions create a fiber optic tip-to-tip solution for data centers and storage area networks (SANs)

More information

AMP NETCONNECT* Gen II Vertical Storage Area Management (SAM) System

AMP NETCONNECT* Gen II Vertical Storage Area Management (SAM) System AMP NETCONNECT* Gen II Vertical Storage Area Management (SAM) System Application Specification 114-32037 29 AUG 12 NOTE i All numerical values are in metric units [with U.S. customary units in brackets].

More information

Arecont Vision MegaDome 2 Installation Manual (DN Models Only)

Arecont Vision MegaDome 2 Installation Manual (DN Models Only) recont Vision MegaDome 2 Installation Manual (DN Models Only) 0 P age recont Vision MegaDome 2 Installation Manual (DN Models Only) MegaDome 2 Installation Manual (DN Models Only). recont Vision MegaDome

More information

C5C Cross-Connect System

C5C Cross-Connect System C5C Cross-Connect System I N S T A L L A T I O N I N S T R U C T I O N High-Density Connection Blocks 1.0 General Product Information The C5C cross-connect system is comprised of a high-density connection

More information

TABLE OF CONTENTS 1. GENERAL PRECAUTIONS...3

TABLE OF CONTENTS 1. GENERAL PRECAUTIONS...3 OFS EPOXY INSTALLATION FOR FOR ST II+ 640-252-044-04-UNIV Instruction Sheet FIBER OPTIC CONNECTORS Comcode: D05AK0035 (MULTIMODE AND SINGLEMODE) USING UNIVERSAL POLISHING PROCEDURE TABLE OF CONTENTS 1.

More information

Written By: Evan Noronha

Written By: Evan Noronha Replace just the front panel not including the home button assembly, front-facing camera and sensor assembly, or earpiece speaker in an iphone 6s Plus. Written By: Evan Noronha ifixit CC BY-NC-SA www.ifixit.com

More information

Compact Medium SOLARLOK Junction Box. Application Specification

Compact Medium SOLARLOK Junction Box. Application Specification Application Specification 114-106003 10OCT. 2010 Rev. A2 Compact Medium SOLARLOK Junction Box Application Specification CONTENT 1. Introduction...2 2. Supporting Documents...2 2.1 Drawings...3 2.2 Product

More information

Mission Critical Fiber Optic Solutions

Mission Critical Fiber Optic Solutions Mission Critical Fiber Optic Solutions Military Fiber Optics Timbercon manufactures fiber optic products that are used in a variety of military applications requiring rigorous testing and certification

More information