Technical Publication

Size: px
Start display at page:

Download "Technical Publication"

Transcription

1 Installation Guidelines HELIAX FiberFeed Direct Solution: Direct Connect Bird Resistant Solution Related Support and Learning Opportunities Offered by the CommScope Infrastructure Academy The insights and expertise contained in this manual represent just one small part of CommScope's global learning initiative. Few industries are evolving as quickly as wireless communications. Every technological innovation impacts what happens in the field. Our customers look to the CommScope Infrastructure Academy to make sure their technicians and installers are well trained, well-prepared, and well-educated to take advantage of opportunities as they evolve. To access a course, go to course #0 Field Engineering Services (FES) Support services, such as our Field Engineering Services (FES) Group gives CommScope customers access to technical support where and when it is needed the most in the field. The FES team is staffed by an expert team of technicians who, in turn, are supported by some of the brightest and most experienced product line managers. Section : Direct Breakout Components / Accessories Section : Color Coding Section : Hoisting Considerations Section : DCM-U Mounting Section : All-in-One Cleaner / Inspecting Section :General Specifications Fibre Tails Section : DFJ-SB Fibre Tail Installation Section : DFJ-SB Fibre Tail Installation Section : DFJ-SB Fibre Tail Installation Section 0: Excess Cable Management Section : MPO Installation / Wiring Section : Jacketing Removal Procedure / Reel Packaging Section : Installation Check List For more information, Contact Customer Service Center Australia Tel 0 00 or Toll Free on 00 0 United States and Mexico or --- International: +--- For the most current, up-to-date information on all our products and product information please visit our ecatalog section at Visit for complete specifications on all the products listed Bulletin # 0 Rev. J

2 Section : HELIAX FiberFeed Direct Components Supports up to RRU's (Fibre and Power tails to RRU shown for clarity) RRU Fibre tail Power tail Power conductors Mounting Kit Included Part Number: DCM-U (additional components may be required based on installation configuration) Separate Fibre and power conductors Direct Breakout canisters Minimum Distance 0. m (. ft) Maximum hanger spacing 0. m ( ft) -. m ( ft) Hybrid FiberFeed Cable Equipment cabinet / shelter Accessories! Cable Series FDH0, 0, 0 FDH0, 0 Part Number A- A- Description Standard Hanger Standard Hanger WARNING: CommScope Hybrid FiberFeed cables require the use of approved installation accessories. FDH0 Bird proof Tails / Power conductors FA--STH FA--STH Standard Hanger Standard Hanger with grommet FDH0, 0, 0 FDH0, 0 FDH0 DFJ-SB B-C -C -C FA-BPB-NOK Hoisting Grip (lace-up) Mounting bracket All Angle Adapter, compact / in tapped hole All FA-0-HC Cable entry seal, - mm (0. -. in) entry panel port size in Visit for complete specifications on all the products listed Bulletin # 0 Rev. J

3 Technical Publication Section : Color Coding Fibre End RRU End Color End Color RED GREEN RED BLUE YELLOW WHITE GREEN BLACK RED (X) GREEN (X) BLUE BLUE (X) Power End Label Color End Conductor Color Label Color RED w/ stripe RED w/ stripe RED GREEN w/ Violet stripe GREEN w/ Violet stripe GREEN BLUE w/ Green stripe BLUE w/ Green stripe BLUE RED (X) w/ Brown stripe RED (X) w/ Brown stripe RED (X) GREEN (X) w/ Yellow stripe GREEN (X) w/ Yellow stripe GREEN (X) BLUE (X) w/ White stripe BLUE (X) w/ White stripe BLUE (X) RED (X) w/ stripe RED (X) w/ No stripe RED (X) GREEN (X) w/ No stripe GREEN (X) w/ stripe GREEN (X) BLUE (X) w/ Gray stripe BLUE (X) w/ Gray stripe BLUE (X) End BBU Visit for complete specifications on all the products listed Bulletin # 0 Rev. J

4 Section : Hoisting Considerations In general this cable will handle similarly to coaxial cable, and similar installation techniques apply. All cables are individually serialized, be sure to write down the cable serial number for future reference. Leave the protective sock around the Fibre tails and power conductors during hoisting and securing the cable. Be sure that the Direct breakout is not damaged by attachment of a hoisting grip or during the hoisting process. Attach a hoisting grip on the jacketed cable no less than. m ( ft) below the Fibre breakout point. Prevent the Fibre tails and power conductors from undue movement during hoisting by securing the protective sock with tie ropes every m ( ft) to the hoisting line. During hoisting ensure that there is a free path and that the cable, and especially the end of the pulling sock will not be snagged on tower members or other obstacles. Installation temperature range is -0 C to +0 C (0 F to + F). Minimum cable bend radii can be found on-line in our ecatalog section at Maximum cable tensile load can be found on-line in our ecatalog section at CommScope Lace-Up Hoisting Grip B-C required for 0, 0, and 0 installations. CommScope Lace-Up Hoisting Grip -C required for 0 and 0 installations. CommScope Lace-Up Hoisting Grip -C required for 0 installations. Hoisting Grip should be anchored to the support structure after the hangers are installed. During final connections to RRU, do not bend the Fibre ends tighter than 0 mm (. in) bend radius or you take the risk of breaking the glass Fibres.! Hybrid Fibre Cables weigh more than traditional coaxial cables. Be sure to follow proper hoisting and attachment procedures. Hoisting Recommendations Direct Breakout -Fibre ODC compatible connectors (D) (D) Grip Location Reminder: Plan grip location by measuring distance (D) from ODC compatible connector to tower support member. Visit for complete specifications on all the products listed Bulletin # 0 Rev. J

5 Hoisting Considerations Tie back ropes m ( ft) Steel cable or rope hoist line! Required Apply provided Tie Wrap to the base of the hoisting grip before applying tension to the line. Maximum 0 m (00 ft) between hoisting grips Clevis Hoisting grip Visit for complete specifications on all the products listed Bulletin # 0 Rev. J

6 Section : DCM-U Mounting To Canister Side View Top View Additional Hose Clamp (based on pipe dia.) Angle adapter (UA-) Hardware Insert (UAAI) Stand Off Hose Clamp To Structure Angle Adapter and Hose Clamp Angle Adapter Pipe mount side view Steel support side view Visit for complete specifications on all the products listed Bulletin # 0 Rev. J

7 Section : All in one cleaner Device designed for cleaning the ferrule end faces of Fibre connectors Open guide cap, insert connector into guide, push the outer shell to start cleaning the connector interface, a "click" sound indicates end of a cleaning process, repeat, close cap immediately after use. Caution: Be careful not to slant connector while inserting into the Guide cap. Do not overly exert force during insertion as this may cause damage to both the connector and the cleaner. Connector Cap Guide Part Number: FCCT - L (shown) Push Cleaner X Part Number Description FCCT MPO MPO Connectors FCCT ODC ODC compatible connector FCCT L DLC Connectors Inspecting There are basic principles that are critical to achieving an efficient Fibre optic connection:. Perfect Core Alignment. Physical Contact. Pristine Connector Interface Scan to view video Today s connector design and production techniques have eliminated most of the challenges to achieving core alignment and physical contact. What remains challenging is maintaining a pristine end-face. As a result, CONTAMINATION is the # reason for troubleshooting optical networks. Implementing the process of cleaning and inspecting before mating can reduce the time spent troubleshooting, optimize signal performance and prevent damage. Clean Inspect Is It Clean? Clean No Yes Connect! Abrasive particles (i.e. rock dust) can cause permanent damage to the interface. If interface is scratched it cannot be repaired, it would need to be replaced. Visit for complete specifications on all the products listed Bulletin # 0 Rev. J

8 Section : General Specifications Fibre Tails The terminated Fibre ends however are fragile and must be protection during installation. Leave the packaging around the Fibre ends in place until ready to make final connect of the jumper at the RRU or BBU. DO NOT BEND THE Fibre ENDS TIGHTER THAN 0 mm (. in) BEND RADIUS ELSE THERE IS A RISK OF BREAKING THE GLASS FibreS. Attach the main cable securely to the structure or equipment using hangers to prevent strain on connections from movement in wind or snow/ice conditions. Ensure the Fibre and power connections and seated firmly in the RRU. Installation temperature range is -0 C to +0 C (0 F to + F). All tails are individually serialized, for immediate access to test results visit General Specifications Brand Fibre Type Jacket Color Interface: End Interface: End Dimensions Cable Weight Diametre Over Bird Proofing Physical Specifications Minimum Bend Radius, loaded Minimum Bend Radius, unloaded Tensile Load, long term, maximum Tensile Load, short term, maximum HELIAX FiberFeed Bend insensitive single mode Fibre (G..A) DLC ODC compatible (IP). kg/km. lb/kft mm. in cm. in cm. in N lbf 0 N 0 lbf Huawei PART NUMBER DFJ-SB-xxM DESCRIPTION SM Fibre, breakout for Huawei RRU Nokia PART NUMBER DFJ-SB-xxM DESCRIPTION SM Fibre, breakout for Nokia Port RRU Nokia PART NUMBER DFJ-SB-xxM DESCRIPTION SM Fibre, breakout for Nokia Port RRU Visit for complete specifications on all the products listed Bulletin # 0 Rev. J

9 Section : Fibre Tail Installation DFJ-SB Tighten the ODC compatible connectors to N m (. in lb). Slide protective sleeve over the connectors and onto the protective sleeve. mm (. in) Tighten both ends of the protective sleeve. Place gland nut on edge of RRU. Connect the Fibre to the RRU then tighten the RRU clamp on corrugated sleeve over Fibre subunit. + - Corrugated sleeve Gland Nut Visit for complete specifications on all the products listed Bulletin # 0 Rev. J

10 Power Tail Installation to RRU After the trunk cable is mounted measure distance X to determine the length of the bird resistant sleeve and power conductor. Remove bird resistant connector by loosening the gland nut. Open the safety clip with a screwdriver. Pull the connector off the bird resistant sleeve. Push the safety clip back into the connector. X Cut bird resistant sleeve at X. Be careful not to cut the power conductor inside of the bird resistant sleeve. Dispose of excess bird resistant sleeve. a For RRUs,, 0 and cut the power conductor to 00 mm (. in). Dispose of excess power conductor. b For RRUs and cut the power conductor to mm (. in). Dispose of excess power conductor. 00 mm (. in) mm (. in) X Remove the jacketing to expose the blue/ black conductors. a For RRUs,, 0 and slide mm conduit inside of power tail bird resistant sleeve. Replace bird resistant connector by sliding connector over cable while twisting clockwise. Tighten the gland nut on the power cable. Visit for complete specifications on all the products listed Bulletin # 0 Rev. J 0

11 b For RRUs and remove mm of length from the mm conduit Place tape at end of conduit then slide the conduit inside of power tail bird resistant sleeve. Replace to build up thickness with for bird resistant connector by sliding connector over cable while twisting proper clamp seal clockwise. Tighten the gland nut on the power cable. X! Feed power conductor into power box. Prep cable to dimensions listed on cover. Wire RRU and close lid. Cable gland needs to be flush with the bottom of the power box. Close door, install locking screws. RRU If jumper breakouts require staggering, install additional provided piece of bird resistant sleeve to cover both jumpers between the RRU and lower grommet. Close door, install locking screws. RRU Additional bird resistant sleeve ( mm dia. 0 mm length) Power Fibre Visit for complete specifications on all the products listed Bulletin # 0 Rev. J

12 Technical Publication Section : Fibre Tail Installation DFJ-SB Slide protective sleeve of trunk Fibre tail. Tighten the ODC compatible connectors to N m (. in lb). Slide protective sleeve over the ODC compatible connectors and tighten both ends. Remove top plate of the mounting bracket and mount to the RRU mounting plate. The screw and nut are fixed to the bracket. Fibre Ports Mounting bracket RRU Part Number: FA-BPB-NOK Mounting hardware RRU Mount Connect DLC connectors and install the weather seal boots. Visit for complete specifications on all the products listed Bulletin # 0 Rev. J

13 Slide bird resistant sleeve to cover Fibre boot. Reinstall top plate of the mounting bracket Tighten protective sleeves to the jumper sleeves. Power Tail Installation to RRU After the trunk cable is mounted measure distance X to determine the length of the bird proofing and power conductor. Remove bird resistant connector by loosening the gland nut. Open the safety clip with a screwdriver. Pull the connector off the bird resistant sleeve. Push the safety clip back into the connector. X Visit for complete specifications on all the products listed Bulletin # 0 Rev. J

14 Cut bird resistant sleeve at X. Be careful not to cut the power conductor inside of the bird proofing. Dispose of excess bird resistant sleeve. Cut the power conductor to 0 mm (. in). Dispose of excess power conductor. 0 mm (. in) X Replace bird resistant connector by sliding connector over cable while twisting clockwise. Tighten the gland nut on the power cable. Slide the protective sleeve and power weatherproofing boot over power cable. Connect the power conductors to the RRU and slide the power weatherproofing boot into place. Connect the power conductors to the RRU and slide the power weatherproofing boot into place. Slide the protective sleeve over the power weatherproofing boot. Connect aluminum bracket to the RRU with screw provided. + GND Visit for complete specifications on all the products listed Bulletin # 0 Rev. J

15 Section : Fibre Tail Installation DFJ-SB Tighten the ODC compatible connectors to N m (. in lb). Slide protective sleeve over the connectors and onto the protective sleeve. mm (. in) Tighten both ends of the protective sleeve. Route Fibre to RRU, connect and lock gland on the RRU entry plate before installing cover. Entry plat will sit on the threaded portion of the gland nut. Visit for complete specifications on all the products listed Bulletin # 0 Rev. J

16 Power Tail Installation to RRU After the trunk cable is mounted measure distance X to determine the length of the bird resistant sleeve and power conductor. Remove bird resistant connector by loosening the gland nut. Open the safety clip with a screwdriver. Pull the connector off the bird resistant sleeve. Push the safety clip back into the connector. X Cut bird resistant sleeve at X. Be careful not to cut the power conductor inside of the bird proofing. Dispose of excess bird proofing. Replace bird resistant connector by sliding connector over cable while twisting clockwise. Tighten the gland nut on the power cable. X Route power to RRU, Connect and lock gland on the RRU entry plate before installing cover. Entry plate will sit on the threaded portion of the gland nut. + GND Fibre Power Visit for complete specifications on all the products listed Bulletin # 0 Rev. J

17 Section 0: Excess Cable Management If length of cable installed needs to be adjusted you can split the cable at the BBU end using the process below and then coiling the excess Fibre subunits in a storage box. Patch Panel Kits are available to manage any excess Fibre length in the breakouts at the BBU. Mark cutback length Notch Armor using flush cutter in-line with Kevlar strings Place Rip Cord in Notches Pull Rip Cord Parallel to Cable (while supporting breakout) Excess Fibre storage Box Part Number: FE--E Patch Panel Kit Part Number: HFF-SMPK-SS- Stop at Length Marker Separate Armor Cable Splitter tool Part Number: FA-RCRT-PD Cut Armor Using Side Cutter Remove Water Blocking Tape NOTE: Step can be expedited by using a sewing seam ripper that can be purchased at local hobby stores Seam Ripper 0 Remove Excess Rip Cord Apply Electrical Tape to Protect Breakout NOTE: Remember to slide identifier labels down the power conductors before trimming the cable to its final length Scan to view video Visit for complete specifications on all the products listed Bulletin # 0 Rev. J

18 * * * Technical Publication Section : MPO Installation / Wiring Front View Back View A B C D E F G H J K L M Cable Cable Cable Expansion slots Subunits can enter from bottom (as shown) or top Mount the rack with provided installation instructions. Remove the slot covers from A - F. G - M are expansion slots Carefully coil excess Fibre subunit inside of the rack. (Rack will accommodate 0 Metres of excess Fibre) Feed the Fibre subunit thru the slot marked A and the Fibre subunit thru the slot marked B. X A B C D E F G H J K L M 0- Part Number: 0DM-LC-SM 0-0- A B C D E F G H J K L M 0-0- Remove the dust caps from the MPO connectors and clean with an all-in-one cleaner (FCCT-MPO). Remove the dust caps from the Fibre cassettes and clean with an all-in-one cleaner (FCCT-MPO). 0- Connect the MPO connectors to the base of the Fibre cassettes. The Beta label should be on the bottom as shown. A B C D E F G H J K L M A B C D E F G H J K L M 0-0- Carefully install the cassettes into the slots making sure the Beta label is still on the bottom. A B C D E F G H J K L M Repeat steps - for Cables and using slots C - F. Note: Do not install in a rainy or windy environment without additional shielding of the exposed MPO s. The exposure of the exposed MPO to the outdoor environment should be minimized even under ideal conditions. Visit for complete specifications on all the products listed Bulletin # 0 Rev. J

19 0-0- Technical Publication Cable Wiring Fibre Cable Wiring Fibre Cable Wiring Fibre BBU End Patch Panel RRU End Trunk BBU End Patch Panel RRU End Trunk BBU End Patch Panel RRU End Trunk 0- A 0- C 0- E 0- A B C D E F G H J K L M B 0- D 0- F Power Power Power BBU End Patch Panel Pair RRU End Trunk BBU End Patch Panel Pair RRU End Trunk BBU End Patch Panel Pair * A B C D E F G H J K RRU End Trunk Pair Pair Pair Pair Pair Pair Pair Pair Pair Pair Pair Pair Pair Pair Pair Visit for complete specifications on all the products listed Bulletin # 0 Rev. J

20 Section : Jacketing Removal Procedure. Score the jacketing 0º. Measure mm ( in) and repeat. Identify where the aluminum shielding overlaps, this will feel like a flat spot in the cable. Remove a section of jacketing between score marks. Lift edge of jacketing. Grab lifted edge of jacketing with a pair of pliers and roll on the cable. Remove excess adhesive with a piece of emery cloth Scan to view video Reel Packaging After shipment arrives take extra care when removing the over packing. Remove reel from box or cut strap holding the reel to the shipping pallet. Take care not to damage the assembly as you roll the reel to installation location. Excessive nicks and cuts in the outer jacketing can cause failure. Place reel on stands to lift off the ground so the reel can spin freely while still being controlled by hand. Lift the shrink wrap away from the cable before cutting. Cable is transported on a double flange reel so both ends may be accessed for pre-testing if required. Place reel on jack stands Carefully remove shrink wrap Visit for complete specifications on all the products listed Bulletin # 0 Rev. J 0

21 Installation Check List Tails are properly supported to prevent strain on Fibre during severe weather Bend radius minimums haven't been exceeded CommScope approved installation accessories are used Maximum hanger spacing of 0. m ( ft) -. m ( ft) is maintained Visually inspected end face for residual dirt and damage Avoid migration of contaminations from one connector to another Check continuity by using LED or lazer light source from one end face and look for light from other end to identify any broken Fibre (Do not look directly at cable with lazer source) Fibre Connections are engaged and the sectors are consistent with requirements Cable serial number has been documented in the closeout paperwork and a copy has been left on-site CommScope 00 CommScope Place SE P.O. Box, Hickory, NC 0-0 () -00 (00) -0 Customer Service hours North America: (toll free) Any country: acicustomersupportcenter@commscope.com Notice: CommScope disclaims any liability or responsibility for the results of improper or unsafe installation, inspection, maintenance, or removal practices. Aviso: CommScope no acepta ninguna obligación ni responsabilidad como resultado de prácticas incorrectas o peligrosas de instalación, inspección, mantenimiento o retiro. Avis : CommScope décline toute responsabilité pour les conséquences de procédures d installation, d inspection, d entretien ou de retrait incorrectes ou dangereuses. Hinweis: CommScope lehnt jede Haftung oder Verantwortung für Schäden ab, die aufgrund unsachgemäßer Installation, Überprüfung, Wartung oder Demontage auftreten. Atenção: A CommScope abdica do direito de toda responsabilidade pelos resultados de práticas inadequadas e sem segurança de instalação, inspeção, manutenção ou remoção. Avvertenza: CommScope declina eventuali responsabilità derivanti dell esecuzione di procedure di installazione, ispezione, manutenzione e smontaggio improprie o poco sicure. 0 CommScope Visit for complete specifications on all the products listed Bulletin # 0 Rev. J

Technical Publication

Technical Publication Discrete Solution: 12 Fiber Trunk / 4 and 8 Conductor Power Trunk Installation Related Support and Learning Opportunities Offered by the CommScope Infrastructure Academy The insights and expertise contained

More information

Technical Publication

Technical Publication Installation Guidelines HELIAX FiberFeed Solutions Hybrid Cables: HFT1206-2SV2 Low Inductance HFT06-8SV2 Low Inductance HFT10/12 Jumpers Related Support and Learning Opportunities Offered by the CommScope

More information

Technical Publication

Technical Publication Installation Guidelines HELIAX FiberFeed 6 and 12 RRU Solution: Pendant Configuration Related Support and Learning Opportunities Offered by the CommScope Infrastructure Academy The insights and expertise

More information

Pre-Testing and Configuring of. RET Antenna Systems. Prior to Installation. Overview

Pre-Testing and Configuring of. RET Antenna Systems. Prior to Installation. Overview Pre-Testing and Configuring of RET Antenna Systems Prior to Installation Overview Bulletin 653260 Revision B July 2014 CommScope Customer Service 24 hours 1100 CommScope Place SE P.O. Box 339, Hickory,

More information

MASTERLINE Ultimate Hybrid High Voltage 4/12 (MLUH HV 4/12) blunt cut at BTS side

MASTERLINE Ultimate Hybrid High Voltage 4/12 (MLUH HV 4/12) blunt cut at BTS side INSTALLATION MANUAL HUBER+SUHNER AG Fiber Optics MASTERLINE Ultimate Hybrid High Voltage 4/12 (MLU HV 4/12) blunt cut at BTS side DOC-0000803885 Rev A June 18, 2018 Page 1 of 12 (MLUH HV 4/12) blunt cut

More information

G12/G12x USER S MANUAL

G12/G12x USER S MANUAL G12/G12x USER S MANUAL TABLE OF CONTENTS SECTION 1 SLIDE CONFIGURATION SECTION 2 SLIDE CONFIGURATION ACCESSORIES SECTION 3 TABLETOP CONFIGURATION SECTION 4 TABLETOP CONFIGURATION ACCESSORIES SECTION 5

More information

TABLE OF CONTENTS SECTION 1 TABLETOP CONFIGURATION SECTION 2 TABLETOP CONFIGURATION ACCESSORIES SECTION 3 SLIDE CONFIGURATION

TABLE OF CONTENTS SECTION 1 TABLETOP CONFIGURATION SECTION 2 TABLETOP CONFIGURATION ACCESSORIES SECTION 3 SLIDE CONFIGURATION S6 USER S MANUAL TABLE OF CONTENTS SECTION 1 TABLETOP CONFIGURATION SECTION 2 TABLETOP CONFIGURATION ACCESSORIES SECTION 3 SLIDE CONFIGURATION SECTION 4 SLIDE CONFIGURATION ACCESSORIES SECTION 5 RACK MOUNT

More information

TECHKNOW, INC. Kiosk Order Confirmation System INSTALLATION MANUAL. Revision Date: July 11, 2012 Part # Version 3.2

TECHKNOW, INC. Kiosk Order Confirmation System INSTALLATION MANUAL. Revision Date: July 11, 2012 Part # Version 3.2 document Page 1 of 18 TECHKNOW, INC Kiosk Order Confirmation System INSTALLATION MANUAL Revision Date: July 11, 2012 Part # Version 3.2 Techknow, Inc. 393 Mayfield Road Duncan, SC 29334 www.gotechknow.com

More information

NASDAQ: TESS. Verizon Wireless. Commscope Hybrid BOM

NASDAQ: TESS. Verizon Wireless. Commscope Hybrid BOM NASDAQ: TESS Verizon Wireless Commscope Hybrid BOM VZW HELIAX FiberFeed Trunk Cables FiberFeed trunk cable assemblies are factory constructed specifically for the devices listed in the Commscope guide

More information

WEB Revision T, May 2016 CommScope Actuators

WEB Revision T, May 2016 CommScope Actuators Revision T, May 2016 CommScope Actuators ATM200-002, ATM200-A20, E-ATM300 This bulletin covers installation procedures for our CommScope line of actuators. Please refer to system configuration diagrams

More information

Gateway Profile 4 service guide

Gateway Profile 4 service guide Gateway Profile 4 service guide Customizing Troubleshooting Contents Replacing Components in Your Gateway Profile 4.................. 1 About this guide.....................................................

More information

Product Classification. General Specifications. Construction Materials. Dimensions. Environmental Specifications. General Specifications

Product Classification. General Specifications. Construction Materials. Dimensions. Environmental Specifications. General Specifications Product Classification Portfolio FD2606-24S55-250250 HELIAX FiberFeed Pendant, 2.0, 3 x 12: Six 6 AWG conductors, 24 single mode fibers. Top breakout: 6 HQLC connector outputs. Bottom breakout: blunt cut

More information

HD Flex Zero RU Cassette Holder and Bracket

HD Flex Zero RU Cassette Holder and Bracket HD Flex Zero RU Cassette Holder and Bracket Part Numbers: FLEX-0RUBR**, FLEX0RUCH** Panduit Corp. 2016 INSTALLATION INSTRUCTIONS The Zero RU Cassette Holder and Bracket are designed to mount on the side

More information

Outdoor PTZ. Mounting on the Ceiling Using Pendant Mount. Installation Guide. For Models: I93, I94, I95, I96, KCM /12/03

Outdoor PTZ. Mounting on the Ceiling Using Pendant Mount. Installation Guide. For Models: I93, I94, I95, I96, KCM /12/03 Outdoor PTZ Mounting on the Ceiling Using Pendant Mount For Models: I93, I94, I95, I96, KCM-8211 2013/12/03 Table of Contents Mounting Solutions... 3 Straight Tube Installation Procedures... 4 Step 1:

More information

Mounting on the Ceiling Using Flush Mount (Face Down)

Mounting on the Ceiling Using Flush Mount (Face Down) Mounting on the Ceiling Using Flush Mount (Face Down) Installation Guide 2014/02/14 Table of Contents Safety Information... 3 Installation Procedures... 5 Step 1: Drill a Hole on the Ceiling... 5 Step

More information

MCH WIRE HARNESS WITH QUICK DISCONNECT REPLACEMENT Initial Release 1/31/2013

MCH WIRE HARNESS WITH QUICK DISCONNECT REPLACEMENT Initial Release 1/31/2013 1. Table of Contents 1. Table of Contents Page 1 2. Remove Failed MCH-103.2 Page 1 3. Install MCH-103.2 to MCH-102NW Page 2 4. Install NC3FX-HD to MCH-103.2 Page 3 5. Install MCH-103.2 Battery Terminal

More information

Rack Installation Instructions

Rack Installation Instructions Rack Installation Instructions Review the documentation that comes with your rack cabinet for safety and cabling information. Before installing your server in a rack cabinet, review the following guidelines:

More information

ONE SD-LAN Wall Mount Splitter Housing (1LAN-SPLT C)

ONE SD-LAN Wall Mount Splitter Housing (1LAN-SPLT C) CMA-477-AEN 1 General Figure 1 STANDARD RECOMMENDED PROCEDURE 000-000-AEN ISSUE 1 MARCH 2018 I Page 1 2 Carton Contents Installation instruction Wall Mount Splitter housing Cable installation hardware

More information

LARGE S URGE-PROTECTOR S HELTER

LARGE S URGE-PROTECTOR S HELTER LARGE S URGE-PROTECTOR S HELTER The weather-resistant Large Surge-Protector Shelter (simply referred to as the shelter in this manual) provides protection from the elements for Surge Protectors (not included)

More information

Dell Inspiron N5110 Service Manual

Dell Inspiron N5110 Service Manual Dell Inspiron N5110 Service Manual Regulatory model: P17F Regulatory type: P17F001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer.

More information

Upgrade Instructions. P/N Revision A. October Printer Terminal Holder * *

Upgrade Instructions. P/N Revision A. October Printer Terminal Holder * * Upgrade Instructions P/N 96-08-0 Revision A October 000 480 Printer Terminal Holder P/N 96-08-0 Revision A *96080* Instructions This terminal holder connects the INTERMEC R 600 Series and 700 Series Computers

More information

SYSTIMAX 360 PATCHMAX Modular Panel Instructions

SYSTIMAX 360 PATCHMAX Modular Panel Instructions Issue 1, February 2015 SYSTIMAX 360 PATCHMAX Modular Panel Instructions General The SYSTIMAX 360 PATCHMAX modular panel can be used for both EIA-T568A or EIA-T568B wiring applications and is an approved

More information

M204SMB Surface Mount Box Instructions

M204SMB Surface Mount Box Instructions Instruction Sheet 860337070 Issue 7, June 2013 M204SMB Surface Mount Box Instructions General The CommScope M204SMB surface mount box (SMB) is designed for interior surface-mounted applications and can

More information

SYSTIMAX 360 ipatch 96F LC Upgrade Kit

SYSTIMAX 360 ipatch 96F LC Upgrade Kit Issue 5, July 2016 SYSTIMAX 360 ipatch 96F LC Upgrade Kit General ipatch Upgrade Kits adapt previously installed SYSTIMAX InstaPATCH LC and HD shelves to ipatch fiber shelves to enable ipatch system high

More information

Rack Installation Instructions

Rack Installation Instructions Rack Installation Instructions Review the documentation that comes with your rack cabinet for safety and cabling information. Before installing your server in a rack cabinet, review the following guidelines:

More information

A-dec 570L Dental Light on a DCS System INSTALLATION GUIDE

A-dec 570L Dental Light on a DCS System INSTALLATION GUIDE A-dec 570L Dental Light on a DCS System INSTALLATION GUIDE C ONTENTS Choose an Installation Guide...... Before You Begin.............. 3 Disconnect the Light Cable........ 3 Cut the Light Cable............

More information

IBM. Rack Installation Instructions

IBM. Rack Installation Instructions IBM Rack Installation Instructions Review the documentation that comes with your rack cabinet for safety and cabling information. When installing your server in a rack cabinet, consider the following:

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS AFL TITAN RTD Multiport Terminal AFL TRIDENT Hardened Drop TABLE OF CONTENTS GENERAL... 2 SPECIFICATIONS... 2 PACKAGE CONTENTS... 3 REQUIRED TOOLS... 3 ADD-ON COMPONENTS... 3 TERMINAL MOUNTING STRAND...

More information

Description: Detailed procedure on removing old bushing and installing new Brake Bushing Replacement Kit 10447

Description: Detailed procedure on removing old bushing and installing new Brake Bushing Replacement Kit 10447 Procedure: BRAKE BUSHING REPLACEMENT PROCEDURE Product: Document #: Rev: Page: MODEL 7000, 7000A, & 8000 GYRO 078 1 1 of 14 Description: Detailed procedure on removing old bushing and installing new Brake

More information

Dell XPS L702X Service Manual

Dell XPS L702X Service Manual Dell XPS L702X Service Manual Regulatory model: P09E series Regulatory type: P09E002 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer.

More information

with Fiber Management Bar

with Fiber Management Bar Issue 1, June 2014 SYSTIMAX 1100A Angled Fiber Termination Panel with Fiber Management Bar General The SYSTIMAX 1100A angled fiber termination panel is a 19 wide x 1.75 high (483mm x 44mm) 1U panel designed

More information

Vacuum Maintenance Manual (EXCERPT Tim Benedict)

Vacuum Maintenance Manual (EXCERPT Tim Benedict) 1. Position a ladder, scaffold, or work stand, on the right side of Vacuum Skid where the blower motors are installed. 2. Locate the six (6) vacuum hoses connecting the blower motors to the HEPA housings

More information

Mini Wall-mount Building Terminal (WBM)

Mini Wall-mount Building Terminal (WBM) Corning Cable Systems Standard Recommended Procedure (SRP) 003-516 Issue 2, October 2004 Page 1 of 8 Contents Figure 1 WBM 1. General...1 2. Description...2 3. Precautions...2 4. Tools and Materials...3

More information

FL1000 Wall-Mount Box Installation and Operation Guide

FL1000 Wall-Mount Box Installation and Operation Guide FL1000 Wall-Mount Box Installation and Operation Guide ONE DOOR (FL1-B) TWO DOOR (FL1-H) 19706-B FL1000 Wall-Mount Box Content Page INTRODUCTION.............................................................................

More information

Removal and Installation8

Removal and Installation8 8 Screw Types 8-4 Top Cover Assembly 8-5 Left Hand Cover 8-6 Right Hand Cover 8-10 Front Panel Assembly 8-14 Left Rear Cover 8-15 Right Rear Cover 8-16 Extension Cover (60" Model only) 8-17 Media Lever

More information

Dell XPS 14z Owner s Manual

Dell XPS 14z Owner s Manual Dell XPS 14z Owner s Manual Computer model: L412z Regulatory model: P24G series Regulatory type: P24G001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better

More information

Rack Installation Instructions

Rack Installation Instructions Rack Installation Instructions Review the documentation that comes with your rack cabinet for safety and cabling information. When installing your server in a rack cabinet, consider the following: v Two

More information

Pretium Rack-mountable 1U Housing Hardware

Pretium Rack-mountable 1U Housing Hardware revision history Issue Date Reason for Change table of contents STANDARD RECOMMENDED PROCEDURE 003-649 ISSUE 5 JANUARY 2009 PAGE 1 OF 10 Pretium Rack-mountable 1U Housing Hardware p/n 003-649, Issue 5

More information

Zebra XiIII-Series Printer Safety and Quick Reference Guide

Zebra XiIII-Series Printer Safety and Quick Reference Guide Zebra XiIII-Series Printer Safety and Quick Reference Guide GB Contents Specifications...75 Electrical...75 Environmental Range...75 Fuses...75 Warnings...76 Installation...76 Use of Shielded Data Cables...76

More information

Thanks for shopping with Improvements! Lighted Canterbury Christmas Greenery Doorway Arch Item #548443

Thanks for shopping with Improvements! Lighted Canterbury Christmas Greenery Doorway Arch Item #548443 Thanks for shopping with Improvements! Lighted Canterbury Christmas Greenery Doorway Arch Item #548443 IMPORTANT, RETAIN FOR FUTURE REFERENCE: READ CAREFULLY. PARTS LIST: 2 Metal Plate Stands 5 Greenery

More information

Control Box Setup - PRSalpha

Control Box Setup - PRSalpha 888-680-4466 ShopBotTools.com Control Box Setup - PRSalpha Copyright 2016 ShopBot Tools, Inc. page 1 Copyright 2016 ShopBot Tools, Inc. page 2 Parts List: Hooking Up a PRSalpha Gantry Tool Powering the

More information

Fiber Management Tray (FMT) User Manual

Fiber Management Tray (FMT) User Manual Fiber Management Tray (FMT) User Manual Fiber Management Tray Content Page INTRODUCTION............................................................................. 2 ADMONISHMENTS...........................................................................

More information

Quick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport

Quick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport PTX5000 Packet Transport Router Quick Start September 2017 Part Number: 530-066788 Revision 01 This document describes how to install the Juniper Networks PTX5000 Packet Transport Router. Contents Quick

More information

Replacing the PanelMate Power Pro 1785 Series, PanelMate epro 7585x-8 and 7685x-8 Series Backlight Assembly

Replacing the PanelMate Power Pro 1785 Series, PanelMate epro 7585x-8 and 7685x-8 Series Backlight Assembly Replacing the PanelMate Power Pro 1785 Series, PanelMate epro 7585x-8 and 7685x-8 Series Assembly Introduction The Replacement Kit provides a replacement backlight for the PanelMate Power Pro 1785 Series,

More information

SYSTIMAX GS3 and 1100GS6 Evolve Modular Panel Instructions

SYSTIMAX GS3 and 1100GS6 Evolve Modular Panel Instructions 860509967 Issue 6, May 2014 SYSTIMAX 360 1100GS3 and 1100GS6 Evolve Modular Panel Instructions General The SYSTIMAX 360 1100GS3 (Cat6) and 1100GS6 (Cat6A) Evolve modular panels exceed ISO and TIA Performance

More information

FO Trunk Cable. FO Trunk Cable

FO Trunk Cable. FO Trunk Cable 5 FO Trunk Cable www.easylan.de FO Trunk Cable u 2 to 144 fibers u Various cable types u PC and APC polish u Tuned connectors u Gradations as desired u Up to IP67 u etc. 104 05 FO Trunk Cable Contents

More information

- ELV OVERVIEW. InstallationGuide SUPPLIED PARTS RELATED PARTS. Brackets Fixtures. Other. 1 of 9 IG-STR9-ELV

- ELV OVERVIEW. InstallationGuide SUPPLIED PARTS RELATED PARTS. Brackets Fixtures. Other. 1 of 9 IG-STR9-ELV OVERVIEW The STR9 ELV is a long run, low power, linear surface mount LED lighting system designed for exterior architectural lighting applications. This guide contains important information on planning

More information

LANCER / LANCER EVOLUTION (2008 ) REAR VIEW CAMERA MZ380462EX INSTALLATION AND HANDLING INSTRUCTIONS

LANCER / LANCER EVOLUTION (2008 ) REAR VIEW CAMERA MZ380462EX INSTALLATION AND HANDLING INSTRUCTIONS LANCER / LANCER EVOLUTION (2008 ) REAR VIEW CAMERA MZ380462EX INSTALLATION AND HANDLING INSTRUCTIONS Navigation (MMCS) unit Camera Thank you for purchasing the Mitsubishi Genuine Accessory. To install

More information

Installing a Power over Ethernet injector

Installing a Power over Ethernet injector Installing a Power over Ethernet injector AlphaEclipse StreetSmart and RoadStar signs The instructions in this document explain how to install/replace a Power over Ethernet (PoE) injector in a StreetSmart

More information

Universal Keying Adapter 3+

Universal Keying Adapter 3+ Universal Keying Adapter 3+ The Universal Keying Adapter Version 3+ kit will allow you to key nearly any transmitter or transceiver with a straight key, electronic keyer, computer serial or parallel port

More information

Megatouch FORCE Monitor Chassis Board Replacement

Megatouch FORCE Monitor Chassis Board Replacement Megatouch FORCE Monitor Chassis Board Replacement Visit the Merit Industries, Inc. Web site http://www.meritind.com merit industries, inc. PM0337-01 Rev C Table of Contents FORCE Classic Monitor Chassis

More information

IBM Systems. Quick start guide for IBM System p5 505 ( )

IBM Systems. Quick start guide for IBM System p5 505 ( ) IBM Systems Quick start guide for IBM System p5 505 (9115-505) 1 Before you begin This Quick start guide contains an abbreviated set of setup instructions designed to help you quickly unpack and set up

More information

Inspiron 22. Service Manual Series. Regulatory Model: W17B Regulatory Type: W17B001

Inspiron 22. Service Manual Series. Regulatory Model: W17B Regulatory Type: W17B001 Inspiron 22 3000 Series Service Manual Regulatory Model: W17B Regulatory Type: W17B001 Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your

More information

TABLE OF CONTENTS INTRODUCTION 2 BOTS 3 CABLES BULKHEADS 15 MOUNTING BRACKETS 19 ACCESSORIES 23 CUSTOM PROJECTS 25. Cable Types 10.

TABLE OF CONTENTS INTRODUCTION 2 BOTS 3 CABLES BULKHEADS 15 MOUNTING BRACKETS 19 ACCESSORIES 23 CUSTOM PROJECTS 25. Cable Types 10. CATALOGUE TABLE OF CONTENTS INTRODUCTION 2 BOTS 3 CABLES Cable Types 10 Cable Adaptors 13 BULKHEADS 15 MOUNTING BRACKETS 19 ACCESSORIES 23 CUSTOM PROJECTS 25 With fibre optics becoming the absolute foundation

More information

Phase Loss Protection Upgrade. Phase Loss Protection Upgrade. In this bulletin:

Phase Loss Protection Upgrade. Phase Loss Protection Upgrade. In this bulletin: Phase Loss Protection Upgrade In this bulletin: Introduction... 2 Purpose... 2 General... 2 Applicability... 2 HD3070 Phase Loss Protection Upgrade Kit Parts... 2 Preparation... 4 Install the Phase Loss

More information

Upgrading LVDS Cables Instruction Sheet

Upgrading LVDS Cables Instruction Sheet Upgrading LVDS Cables Instruction Sheet INTRODUCTION Use the following instructions to replace the LVDS cables in CP2000-M/MR projectors. The new cables are slightly longer in length and allow for better

More information

Operators Guide. Pozi-Loc Tripods. Vinten Camera Control Solutions

Operators Guide. Pozi-Loc Tripods. Vinten Camera Control Solutions Operators Guide Pozi-Loc Tripods Vinten Camera Control Solutions Vision Pozi-Loc Tripods Publication Part No. 3770-8 Issue 3 Copyright Vinten Broadcast Limited 2005 All rights reserved throughout the world.

More information

NG3 High-Density Fiber Distribution Frame System Termination, Termination/Splice, VAM, and MPO Panels

NG3 High-Density Fiber Distribution Frame System Termination, Termination/Splice, VAM, and MPO Panels NG3 High-Density Fiber Distribution Frame System Termination, Termination/Splice, VAM, and MPO Panels User Manual ADCP-90-297 Issue 9 3/2010 1685349 Rev A Preface COPYRIGHT All Rights Reserved REVISION

More information

Installation Guide. Retrofit Kit for USB Ready Intraoral Systems

Installation Guide. Retrofit Kit for USB Ready Intraoral Systems Installation Guide Retrofit Kit for USB Ready Intraoral Systems Table of Contents Wall-Mount Retrofit Kit... 2 Introduction... 2 Connecting the Articulating and Horizontal Arm Cables... 2 Installing the

More information

E1135C PDU and Pod Upgrade Procedure

E1135C PDU and Pod Upgrade Procedure E4030-90010 Rev. B 12/2003 In this Document... Tools Needed, 2 Contents of the Upgrade Kits, 2 Installation Procedures, 4 Verifying the Power Option of the New PDU, 4 Removing the PDU from the Support

More information

Schneider Automation Modbus Plus Network Installing Clustered Node Devices Publication: 890 USE Rev. 1.0 Part Number:

Schneider Automation Modbus Plus Network Installing Clustered Node Devices Publication: 890 USE Rev. 1.0 Part Number: Schneider Automation Modbus Plus Network Installing Clustered Node Devices Publication: 890 USE 53 00 Rev..0 Part Number: 3000939 Modbus Plus devices must be installed as specified in a network layout

More information

Cable assembly types. L tot. Total length* L tot end-to-end total (min. 0.5 except receptacles)

Cable assembly types. L tot. Total length* L tot end-to-end total (min. 0.5 except receptacles) CABLE ASSEMBLY TYPES Quantity - Please use one request form per cable assembly type End A Cable assembly types End B Patch cord Receptacle Gas tight receptacle L b Breakout L b Single Fiber Drawings are

More information

Modular plugs, accessories and tooling

Modular plugs, accessories and tooling Modular plugs, accessories and tooling Introducing the new Cat 6A/6 modular plugs, slim-line boots and color clips CommScope modular plug portfolio CommScope offers a vast portfolio of Modular Plugs for

More information

Richter Optica. Instructions for: S6-BL, S6-TS, S6-SPS, S6-ILST Models

Richter Optica. Instructions for: S6-BL, S6-TS, S6-SPS, S6-ILST Models Richter Optica info@richter-optica.com Instructions for: S6-BL, S6-TS, S6-SPS, S6-ILST Models Trinocular port for c-mount adapter Zoom Knob Focusing Holder Clamp Diopter adjustable eyepieces Magnification

More information

INSPECTION TOOL. Inspection Video Camera with Color LCD Monitor. EU Environmental Protection. Model: 8802LE,8803LE. Model: 8802LE,8803LE

INSPECTION TOOL. Inspection Video Camera with Color LCD Monitor. EU Environmental Protection. Model: 8802LE,8803LE. Model: 8802LE,8803LE INSPECTION TOOL Inspection Video Camera with Color LCD Monitor Model: 8802LE,8803LE EU Environmental Protection Waste electrical products should not be disposed of with household waste. Please recycle

More information

SAVE THESE INSTRUCTIONS

SAVE THESE INSTRUCTIONS OUTDOOR HARDWIRE INSTALLATION INSTRUCTIONS Please read and save these instructions. Read carefully before using product. Protect yourself and others by observing all safety information, warnings and cautions.

More information

Replacing the Power Supply

Replacing the Power Supply APPENDIX B This appendix includes information on how to replace the power supply for the Cisco AS550XM universal gateway and contains the following sections: Safety Recommendations, page B-1 Required Tools

More information

MulTI-Touch Projected Capacitive Touch Screen Integration Guide

MulTI-Touch Projected Capacitive Touch Screen Integration Guide MulTI-Touch Projected Capacitive Touch Screen Integration Guide Document Number: 6500493 Rev. 1.1 Pg. 1 The information provided in this document is intended as a guide only and is subject to change without

More information

Transparent Covers for Rail-Mounted Terminal Blocks, Usable with Lead Seals Description and Handling

Transparent Covers for Rail-Mounted Terminal Blocks, Usable with Lead Seals Description and Handling Transparent Covers for Rail-Mounted Terminal Blocks, Usable with Lead Seals Description and Handling 572 Assembly Application Snapping a cover carrier onto the carrier rail. Application examples: cover

More information

Design and Manufacture of Video Pipeline Inspection Systems A Full Service Company

Design and Manufacture of Video Pipeline Inspection Systems A Full Service Company Design and Manufacture of Video Pipeline Inspection Systems A Full Service Company www.rstechserv.com Omni Star LED Pan and Tilt Zoom Color Camera Modell 10-1660 INSTALLATION MANUAL Made in USA IMPORTANT

More information

Installation and User Guide

Installation and User Guide Installation and User Guide VADDIO DOMEVIEW HD INDOOR PENDANT MOUNT DOME ENCLOSURE FOR THE VADDIO HD-20, HD-19 AND HD-18 PTZ CAMERAS Part Number: 998-9100-200 2011 Vaddio - All Rights Reserved DomeVIEW

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS 2015 F-150 8 MyTouch factory display 360º Vision System (Kit # AVMS-3618) DUE TO THE COMPLEXITY OF THIS KIT PROFESSIONAL INSTALLATION IS REQUIRED CALIBRATION KIT IS REQUIRED FOR FINAL PROGRAMMING -Must

More information

Conductor and Cable Marking Description and Handling

Conductor and Cable Marking Description and Handling Conductor and Cable Marking Description and Handling 566 Wire marking The following markers are available: Markers for plotter marking. Markers on roll for thermal transfer printing. Remove the printed

More information

ZC-OH5 TAMPER-RESISTANT INDOOR/OUTDOOR HOUSING INSTRUCTION MANUAL FOR USE WITH GANZ ZC-D5000 SERIES MINIDOME CAMERAS

ZC-OH5 TAMPER-RESISTANT INDOOR/OUTDOOR HOUSING INSTRUCTION MANUAL FOR USE WITH GANZ ZC-D5000 SERIES MINIDOME CAMERAS ZC-OH5 TAMPER-RESISTANT INDOOR/OUTDOOR HOUSING INSTRUCTION MANUAL FOR USE WITH GANZ ZC-D5000 SERIES MINIDOME CAMERAS Please carefully read and observe all instructions and warnings contained in this manual

More information

The Nureva Span ideation system. Installation guide. Single panoramic system

The Nureva Span ideation system. Installation guide. Single panoramic system The Nureva Span ideation system Installation guide Single panoramic system Important SAFETY WARNINGS Prior to the installation of this product, the installation instructions should be completely read and

More information

Wall Mounted Building Entrance Enclosure Instructions

Wall Mounted Building Entrance Enclosure Instructions Instruction Sheet 860383587 Issue 8, February 2014 Wall Mounted Building Entrance Enclosure Instructions General The CommScope wall mounted building entrance enclosures are designed to enable field and

More information

Connect Electricians' tools, consumables and enclosures

Connect Electricians' tools, consumables and enclosures Connect Electricians' tools, consumables and enclosures 220 Tooling and consumables including electricians' hand tools, electrical insulation tapes, cable pulling socks, morse hole saws & accessories

More information

NetCommWireless. Quick Start Guide NTC-30 Series - Outdoor WiFi Router

NetCommWireless. Quick Start Guide NTC-30 Series - Outdoor WiFi Router NetCommWireless Quick Start Guide NTC-30 Series - Outdoor WiFi Router NetCommWireless Let s get this show on the road You must be excited to get started with your Outdoor WiFi Router. If all goes to plan,

More information

Inspiron Service Manual. 2-in-1. Computer Model: Inspiron Regulatory Model: P69G Regulatory Type: P69G001

Inspiron Service Manual. 2-in-1. Computer Model: Inspiron Regulatory Model: P69G Regulatory Type: P69G001 Inspiron 13 5000 2-in-1 Service Manual Computer Model: Inspiron 13-5378 Regulatory Model: P69G Regulatory Type: P69G001 Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps

More information

FRU Installation Notes Virtuo Monitor Glass Replacement

FRU Installation Notes Virtuo Monitor Glass Replacement January 2016 900975-001 Rev 00 FRU Installation Notes Virtuo Monitor Glass Replacement Purpose How to replace the touch screen glass on a Virtuo This document is for these components or categories Expected

More information

TrueNet 1U and 2U Fiber Panel Installation and Cable Routing Instructions

TrueNet 1U and 2U Fiber Panel Installation and Cable Routing Instructions TrueNet 1U and 2U Fiber Panel Installation and Cable Routing Instructions ADCP-92-082 Issue 2 10/2008 1U PANEL 2U PANEL 22049-A Content Page INTRODUCTION.............................................................................

More information

Installing the Cisco MDS 9020 Fabric Switch

Installing the Cisco MDS 9020 Fabric Switch CHAPTER 2 This chapter describes how to install the Cisco MDS 9020 Fabric Switch and its components, and it includes the following information: Pre-Installation, page 2-2 Installing the Switch in a Cabinet

More information

Zebra XiII-Series Printer Quick Reference Guide

Zebra XiII-Series Printer Quick Reference Guide Zebra XiII-Series Printer Quick Reference Guide Contents Media and Ribbon Loading...67 Media Loading...67 Ribbon Loading...70 Operator Controls...72 Front Panel Keys...72 Front Panel Lights...72 Calibration...74

More information

BreezeMAX Wi² and BreezeACCESS Wi² Quick Installation Guide

BreezeMAX Wi² and BreezeACCESS Wi² Quick Installation Guide This Quick Installation Guide is intended for experienced installers. For more information refer to the relevant sections in the BreezeMAX Wi² and BreezeACCESS Wi² System Manual. Wi² Package Content Check

More information

Compact Series Wallmount Enclosures

Compact Series Wallmount Enclosures Compact Series Page 1 of 5 Overview ARIA s Compact Series are small wallmount enclosures that features patch and splice capabilities. The enclosures also support 12 fiber MPO to LC connector plug and play

More information

Cutter Option Installation Instructions

Cutter Option Installation Instructions This kit includes the parts and documentation necessary to install the cutter option on the Zebra XiII, XiIII, and XiIIIPlus-Series printers. NOTE: The Cutter Option is not available for the 96XiIII. Adding

More information

Keysight M8000 Series BER Test Solutions

Keysight M8000 Series BER Test Solutions Keysight M8000 Series BER Test Solutions J-BERT M8020A High-Performance BERT M8030A Multi-Channel BERT M8040A High-Performance BERT M8041A, M8051A, M8061A, M8062A, M8045A, M8046A & M8057A Tips for Preventing

More information

Panduit PreConfigured Industrial Distribution Frame (IDF) Installation Instructions Part Numbers ZDF48-RA and ZDF48-EA ZDF48-6RA and ZDF48-6EA

Panduit PreConfigured Industrial Distribution Frame (IDF) Installation Instructions Part Numbers ZDF48-RA and ZDF48-EA ZDF48-6RA and ZDF48-6EA Panduit PreConfigured Industrial Distribution Frame (IDF) Installation Instructions Part Numbers ZDF48-RA and ZDF48-EA ZDF48-6RA and ZDF48-6EA Figure 1: Industrial Distribution Frame (IDF) Equipment Elevation

More information

LED Maintenance Instructions

LED Maintenance Instructions Chapter 5 LED Maintenance Instructions This guide describes the maintenance procedures for the LED portion of your DayStar or TekStar sign. 1.800.237.3928 stewartsigns.com Rev1802 Intentionally Left Blank

More information

DUAL-ARM MONITOR MOUNT For in. ( cm) desktop computer monitors

DUAL-ARM MONITOR MOUNT For in. ( cm) desktop computer monitors LeviTouch DM-502 DUAL-ARM MONITOR MOUNT For 15 27 in. (38.1 68.6 cm) desktop computer monitors User Manual Thank you for choosing Gabor. The Gabor Dual-Arm Desktop Mount can securely support two monitors

More information

Construction Materials. Dimensions. Environmental Specifications. General Specifications. Mechanical Specifications

Construction Materials. Dimensions. Environmental Specifications. General Specifications. Mechanical Specifications 760184002 TeraSPEED LC to SC, Fiber Patch Cord, 1.6 mm Simplex, Plenum Total Fibers, quantity 1 TeraSPEED, zero water peak singlemode fiber (G.652.D, G.657.A1 or G.652.D, G.657.A1 OS2) Dimensions Cord

More information

AMP NETCONNECT* Gen II Vertical Storage Area Management (SAM) System

AMP NETCONNECT* Gen II Vertical Storage Area Management (SAM) System AMP NETCONNECT* Gen II Vertical Storage Area Management (SAM) System Application Specification 114-32037 29 AUG 12 NOTE i All numerical values are in metric units [with U.S. customary units in brackets].

More information

Outdoor FDH Termination Pole-Mount Cabinet With Universal Splitter Chassis User Manual

Outdoor FDH Termination Pole-Mount Cabinet With Universal Splitter Chassis User Manual Outdoor FDH 3000 288 Termination Pole-Mount Cabinet With Universal Splitter Chassis User Manual ADCP-96-184 Issue 1 8/2014 25555-A 300100104431 Rev A Preface COPYRIGHT 2014, Tyco Electronics Corporation

More information

Dell Inspiron XPS and Inspiron 9100 Service Manual

Dell Inspiron XPS and Inspiron 9100 Service Manual Dell Inspiron XPS and Inspiron 9100 Service Manual Dell Inspiron XPS and Inspiron 9100 Service Manual Before You Begin Memory Module, Mini PCI Card, and Devices System Components Subwoofer Bluetooth Card

More information

Product Classification. Construction Materials. Dimensions. Environmental Specifications. General Specifications. Mechanical Specifications

Product Classification. Construction Materials. Dimensions. Environmental Specifications. General Specifications. Mechanical Specifications 760200527 TeraSPEED FC APC to Unconnectorized, Fiber Patch Cord, 1.6 mm Simplex, Plenum Product Portfolio Brand Product Type CommScope TeraSPEED Fiber test patch cord Regional Availability Asia Australia/New

More information

SENC 150 REFERENCE MANUAL

SENC 150 REFERENCE MANUAL SENC 50 REFERENCE MANUAL SENC 50 Table of Contents / Warnings Page Introduction / Supplied items... 4 2 Preparing the mounting / Mounting information... 5 3 Encoder dimensions... 8 4 Backup spar dimensions...

More information

Navigator II INstallatIoN MaNUal For static and PaN/tIlt configurations

Navigator II INstallatIoN MaNUal For static and PaN/tIlt configurations Navigator II Installation MANUAL For Static and Pan/Tilt Configurations Document Number: 432-0001-00-12, rev 100 FLIR Systems, Inc., 2008. All rights reserved worldwide. No parts of this manual, in whole

More information

M215 (M215-60) Safety

M215 (M215-60) Safety M215 QUICK INSTALL GUIDE M215 (M215-60) Safety Important Safety Information This document contains important instructions to use during installation and maintenance of the Enphase M215 Microinverter. To

More information

Parts and Service Manual IMCO

Parts and Service Manual IMCO XXTREME ADVANTAGE Gimbal Parts and Service Manual IMCO 510 East Arrow Highway San Dimas, CA 91773 (800) 899-8058 (909) 592-6162 Fax (909) 592-6052 www.imcomarine.com email info@imcomarine.com TABLE OF

More information

LED Lighting Kit For Elara NanoEdge Fixed Frame. Installation Guide. Attention: Read this guide before assembling your screen.

LED Lighting Kit For Elara NanoEdge Fixed Frame. Installation Guide. Attention: Read this guide before assembling your screen. LED Lighting Kit For Elara NanoEdge Fixed Frame Installation Guide Attention: Read this guide before assembling your screen. INTRODUCTION GETTING STARTED WARNING - Sharp Edges This product may contain

More information