SmartWire Darwin communication system Connect don t wire

Size: px
Start display at page:

Download "SmartWire Darwin communication system Connect don t wire"

Transcription

1 Darwin Technology The easy way to connect SmartWire Darwin communication system Connect don t wire For the manufacturer of machinery and installations, nothing is more important than finding the balance between maximum functionality and optimal costs. Designed for further development, is a communication system for industrial control equipment in control panels and in the periphery: from control, protection and switching to actuation, operation and monitoring. A technology that will win you profits, now and in the future. greatly reduces wiring expenses and helps save costs: from design through construction and commissioning, up to expansions. relies on the proven Eaton Moeller industrial control equipment and enables these devices to communicate. Planning and engineering efficiently Connecting error-free Fast commissioning Convenient operation Maintenance with direct diagnostics Simple expansion Steuern Schützen Schalten Bedienen & Beobachten Antreiben Information about is available in the Online Manual on SmartWire Darwin: System (AWB7-7de) SmartWire Darwin: Gateways (AWB7-de) SmartWire Darwin: Stations (AWB7-de) SmartWire Darwin products in this catalogue: Chap. - SmartWire Darwin - the complete range Chap. - RMQ-Titan pilot devices, RMQ connections Chap. - contactors, contactor modules Chap. 7 - motor-protective circuit-breaker Chap. 9 - soft starter, DS7 Chap. 7 - NZM circuit-breaker to 00 A, interface module 00 CA08000Z-EN

2 communication system (SWD) System Description / System overview / SWD Gateways, I/O modules, power feed modules Ordering / SWD connections at RMQ-Titan pilot devices System overview Ordering /8 /0 SWD modules to connect contactors and motor starters. System overview / Ordering / SWD-capable Soft starter DS7 System overview / Ordering / SWD interface module for NZM circuit-breakers System overview / Ordering / SWD accessories Ordering /7 Engineering Power-/current consumption of the SWD stations /9 Technical data SWD gateways, Powerfeed modules /0 SWD I/O modules / SWD connections at RMQ-Titan pilot devices / SWD modules to connect contactors, motor starters and circuit breaker NZM. / SWD accessories /8 Dimensions SWD modules and RMQ connections /0 Accessories /

3 / Darwin Technology System System Description. Secures your know-how. significantly cuts your wiring requirements and helps you save costs across the entire value chain from design through construction, programming, commissioning to extending your system. Utilizing Eaton s industrial switchgear, is based on tried-and-tested technology. makes Eaton industrial switchgear communications-enabled. Your user program remains intact Incorporating the gateway in the Eaton PLC program is also easy. Only the PLC configuration needs to be modified the user program remains unchanged making the transition any PLC to, including PLC programming quick and easy. Your software expertise is safe! in the STEP 7 PLC configuration in the easysoft-codesys PLC configuration 00 CA08000Z-EN

4 Darwin Technology System / Planning and ordering help (SWD?Assist) Easy generation of applications with the System Integrated function for the generation of ordering lists Integrated plausibility check Online functionality Simple preliminary commissioning of inputs and outputs and function testing Easy diagnostics of slaves Download Free download under Planning a string is quick and easy with the SWD-Assist software System 00 CA08000Z-EN

5 / Darwin Technology System System overview Darwin Technolo gy SWD-Ass ist ller.net/da rwin V.0 0 Planning tool product rangefor the SmartWire-Dar win CA08000Z-EN 0

6 Darwin Technology Gateways, I/O modules, power feed modules / Sub-D data plug, 9 pole contactor module 9 powerfeed module 7 RMQ-Titan surface mounting enclosure gateways blade terminal 8 pole ribbon cable, 8 pole input/output modules device plug 8 pole connection for NZM NZM circuit-breakers 8 7 DILM contactors 0 contactor module with Manual-0-Automatic switch Motor protective circuit breakers MSC motor starters PKE modules PKE motor starters with electronic motor protection DS7 soft starter with PKE electronic motor protection LED elements, front fixing RMQ-Titan mounting adapter for front mounting 8 9 RMQ-Titan indicator light 0 function elements for front fixing operating elements control panel cable adapter for flat to round cable plug connectors card for function elements, base fixing LED elements for base fixing Function elements for base fixing adapter for flat/round cable for top-hat rail mounting network termination for 8 pole ribbon cable DS7 soft starters planning and ordering aid, SWD-Assist round cable, 8 pole Features gateway input/output module Power feeder module Planning and ordering help (SWD-Assist) Connection of to fieldbus. Supports the PROFIBUS-DP and CANopen fieldbuses. Provides of the supply voltage for the slaves. Supplies the control voltage for the motor starters or contactors. Configuration button for automatic addressing of the SmartWire- Darwin slaves. Support of up to 99 SmartWire- Darwin slaves. Connection of the SmartWire- Darwin ribbon cable via blade terminal. Connection to ribbon cable via device plug. Integration of other switching devices without integrated Smart- Wire-Darwin technology. Variant with 8 digital inputs, or digital inputs and non-isolated transistor outputs, or digital inputs and relay outputs 0 V AC. diagnostics LED for signalling of the communication status of the module. Connection to ribbon cable via blade terminal. Provides of the supply voltage for the slaves. Control voltage feeder for the motor starters and contactors. Formation of emergency-stop groups. Easy generation of applications with the system. Integrated function for the generation of ordering lists. Integrated plausibility check. Online functionality Simple preliminary commissioning of inputs and outputs and function testing. Easy diagnostics of SmartWire- Darwin slaves. Free download under Gateways, I/O modules, power feed modules 00 CA08000Z-EN

7 / Darwin Technology Gateways, I/O modules, power feed modules Ordering HPL000EN Description Part no. Article no. Price See price list Std. pack SWD gateways Gateway to the connection to the fieldbus and for supplying the (SWD) slaves and switchgear. Connection to PROFIBUS-DP as slave. Automatic baud rate detection from 9. kbit/s to Mbit/s. Address range -. 9 pole SUB-D socket. Connection of up to 8 SWD slaves. Connection to CANopen as slave. Automatic baud rate detection from 0 kbit/s to Mbit/s. Address range -. 9 pole SUB-D plug. Connection of up to 99 SWD slaves. SWD I/O modules slaves for the connection of digital I/O signals. Digital module with 8 digital inputs V DC Digital module with digital inputs V DC and transistor outputs V DC/0. A Digital module with digital inputs V DC and relay outputs 0 V AC EUC-SWD-DP 08 EUC-SWD-CAN 07 EUE-SWD-8DX 8 EUE-SWD-DD 8 EUE-SWD-DR 8 off off off SWD powerfeed module For additional control voltage supply of the motor starters and contactors. For the formation of emergency-stop groups for the motor starters and contactors. EUC-SWD-PF- 09 off For the supply of other SWD slaves. For additional control voltage supply of the motor starters and contactors. For the formation of emergency-stop groups for the motor starters and contactors. EUC-SWD-PF- 80 off Information relevant for export to North America NA Certification Request filed for UL and CSA UL/CSA approval applied for 00 CA08000Z-EN

8 Darwin Technology Notes /7 Notes 00 CA08000Z-EN

9 Darwin Technology SWD-Assist V.00 product range /8 Darwin Technology SWD RMQ connections SWD RMQ connections Planning tool for the CA08000Z-EN

10 Darwin Technology SWD RMQ connections /9 RMQ-Titan, -way selector switch Chapter RMQ-Titan, M contact elements for front mounting Chapter RMQ-Titan, M contact elements with base fixing Chapter RMQ-Titan, insert labels Chapter 0 RMQ-Titan, label with label mount for -way selector switch and joystick Chapter SWD device plug Page /7 Link for SWD PCB Page / RMQ-Titan, label mount for double actuator pushbuttons Chapter SWD front mounting adapter for M-SWD-K Page / RMQ-Titan, front mounting adapter with three mounting locations Page / SWD function element with positions for front mounting Features SWD LED element for front mounting Features SWD function element with positions for front mounting Features SWD function element with positions and LED for front mounting Features SWD function element with positions and LED for front mounting Features SWD ribbon cable Page /7 SWD-Assist, Planning and ordering help Features RMQ-Titan, surface mounting enclosure Chapter SWD PCB for surface mounting enclosure Features Cable gland for SWD round cable Chapter SWD bulkhead plug/socket RJ with prefabricated signal cables Features SWD socket/plug for round cable Features SWD round cable Page / SWD function element with positions and LED for base fixing Features SWD function element with positions for base fixing Features SWD function element with positions and LED for base fixing Features SWD function element with positions for base fixing Features SWD LED element for base fixing Features RMQ-Titan, bezels Chapter RMQ-Titan, double actuators Chapter RMQ-Titan, indicator light Chapter RMQ-Titan, key-operated actuator Chapter RMQ-Titan, selector switch actuator Chapter RMQ-Titan, button plates/ button lenses Chapter RMQ-Titan, pushbutton actuators Chapter RMQ-Titan, label mounts Chapter RMQ-Titan, emergency stop pushbuttons (for safety circuits use only standard contacts M) Chapter RMQ-Titan, joystick Chapter Link for SWD device plugs Features 0 RMQ-Titan, -way pushbutton Chapter 0 Features SWD-RMQ connection for front fixing Page /0 Link for device plug Page / SWD RMQ connection for base fixing Page /0 Planning and ordering help (SWD Assist) Adaptation with standard adapter M-A or M-SWD-A for -way selector switch/pushbutton and joystick. Combination with standard pilot devices of the RMQ-Titan M serie. Types with one or two change over contacts and with/without integrated LED element. LED elements in four colors. diagnostics LED for signalling of the communication status of the function element. Connection to ribbon cable with device plug.. Connection to device plug. Suitable for bridging adapted external device plugs (e.g. as placeholders). Surface mounting enclosure with PCB Page / Connection of function elements for base fixing. Type with,,, and slots. Bridging of free slots with link for base fixing. Integrated connectable network terminator. For use with SWD PCB, RMQ-Titan surface mounting enclosure and RMQ-Titan M control circuit devices. Types with one or two change over contacts and with/without integrated LED element. LED elements in four colors. diagnostics LED for signalling of the communication status of the function element. Housing bushing socket Page /8 Use for RMQ-Titan M surface mounting enclosure or control panel. Type plug/socket. Prefabricated signal cable with ferrules for connection to PCB for surface mounting enclosure. Easy generation of applications with the system. Integrated function for the generation of ordering lists. Integrated plausibility check. Online functionality: Simple preliminary commissioning of inputs and outputs and function testing. Easy diagnostics of SmartWire- Darwin slaves. Free download under SWD RMQ connections 00 CA08000Z-EN

11 /0 Darwin Technology SWD RMQ connections HPL000EN Ordering Number of contacts Circuit symbol Contact travel diagram in connection with front element Configuration Color LED Part no. Article no. Price See price list Std. pack Function elements Front fixing change over contact without LED M-SWD-K 9 0 off change over contacts without LED M-SWD-K 9 0 off Base fixing change over contact without LED M-SWD-KC 99 0 off change over contacts without LED M-SWD-KC 99 0 off Front fixing change over contact M-SWD-KLED-W 97 0 off M-SWD-KLED-B 97 M-SWD-KLED-G 97 M-SWD-KLED-R 97 change over contacts M-SWD-KLED-W off M-SWD-KLED-B 979 M-SWD-KLED-G 980 M-SWD-KLED-R 98 Base fixing change over contact M-SWD-KLEDC-W 00 0 off M-SWD-KLEDC-B 00 M-SWD-KLEDC-G 00 M-SWD-KLEDC-R 00 change over contacts M-SWD-KLEDC-W off M-SWD-KLEDC-B 00 M-SWD-KLEDC-G 0 M-SWD-KLEDC-R 0 Notes SWD function elements can be combined with RMQ-Titan operating elements M... Chapter Control circuit devices Information relevant for export to North America 00 CA08000Z-EN NA Certification Request filed for UL and CSA UL/CSA approval applied for

12 HPL00EN Darwin Technology SWD contactor modules, SWD PKE module / Configuration Color LED Part no. Article no. Price See price list Std. pack Information relevant for export to North America LED elements Front fixing M-SWD-LED-W 9 M-SWD-LED-B 97 0 off NA Certification Request filed for UL and CSA 0 off UL/CSA approval applied for. M-SWD-LED-G 98 0 off M-SWD-LED-R 99 0 off Base fixing M-SWD-LEDC-W 997 M-SWD-LEDC-B off NA Certification Request filed for UL and CSA 0 off UL/CSA approval applied for. M-SWD-LEDC-G off M-SWD-LEDC-R off Fixing adapters Front fixing For function element M-SWD-K or LED element M-SWD-LED In addition or contact elements M-K.. possible. Sequence number on fixing adapter. M-A 7 M-A-GVP 7 0 off UL/CSA certification not required 00 off UL/CSA certification not required For function elements M-SWD-K... For use with M-WR, -WRJ, -D in conjunction with M-(SWD)-K Printed circuit boards M-SWD-A 0 PCBs for surface mounting enclosure M-I.. for mounting base function elements M-SWD...K. Integrated, connectable SWD network terminator Number of mounting locations: M-SWD-I-LP0 990 IN Link ON OUT OFF Bridging of open mounting locations on M-SWD-I...-LP0 PCB Base fixing M-SWD-I-LP0 99 M-SWD-I-LP0 99 M-SWD-I-LP0 99 M-SWD-I-LP0 99 M-SWD-SEL off NA Certification Request filed for UL and CSA UL/CSA approval applied for. off NA Certification Request filed for UL off and CSA UL/CSA approval applied for. off off off off NA Certification Request filed for UL and CSA UL/CSA approval applied for. Notes SWD LED elements can be combined with RMQ-Titan indication elements M... Chapter "Control circuit devices" SWD contactor modules, SWD PKE module 00 CA08000Z-EN

13 Darwin Technology / Darwin Technology SWD contactor modules, SWD PKE module System overview SWD-Assist V.00 Planning tool for the product range MSC-DEA networkable PKEbased motor starters up to 7kW Features Network terminator Page /7 MSC-R reversing starters based on PKZM0 up to kw Chapter 8 9 Modules SWD PKE modules Features MSC-D DOL starters based on PKZM0 up to 7 kw Chapter 8 MSC-R reversing starters based on PKZM0 up to 7 kw Chapter 8 SWD ribbon cable Page /7 Planning and ordering help, SWD assist Features MSC-DEA networkable PKEbased motor starters up to kw Features MSC-D DOL starters based on PKZM0 up to kw Chapter SWD device plug Page /7 Power feeder module Features SWD input/output module with relay outputs Features 0 SWD contactor module with manual/auto functionality Features SWD contactor module Features Link for device plug Page /7 00 CA08000Z-EN

14 Darwin Technology SWD contactor modules, SWD PKE module / SWD contactor modules, SWD PKE module Features MSC-DEA networkable PKE-based motor starter Chapter 8 Plug & play-capable motor starter combi-nation up to kw, consisting of PKE basic unit, contactor DILM and PKE trip block PKE-XTUA. Exchangeable trip blocks for cover of current ranges. Wide-range overload protection ratio :. Adjustable time-lag classes (CLASS, 0,, 0) for different tripping characteristics. Networkable via SWD PKE module. Powerfeed module Page / Provision of supply voltage. Provision of V DC supply voltage for activating the contactors. Formation of emergency-stop groups. SWD PKE module Page / Pluggable onto contactors in the xstart range. Suitable for motor starters MSC-DEA- ( V DC) or DILM(C)7 -DILM(C) in combination with PKE/ and trip block PKE-XTUA- Use of the standard switchgear of the xstart range. Use of the standard accessories in the xstart range. Integrated mechanical contactor switching state indication. Integrated contactor switching state scanning. Transmission of PKE-specific data (switch position PKE, relative motor current, thermal motor image, trip indications (overload, short-circuit, ), type PKE trip block, set value of overload release and time-lag class). Communication cable (PKE-COM) for connection to PKE trip block included as standard. Contactor actuation. Selectable ZMR functionality (contactor opening on overload). SWD diagnostics LED for signalling the communication status of the modules and signalling of the switch command via. Manual/Auto functionality for automatic or manual switching on of the connected contactor. Connection to ribbon cable via device plug. SWD contactor module Page / Pluggable onto contactors in the xstart range. Suitable for contactors DILM7 DILM8 (VDC), DILMC7 DILMC ( VDC), DILA DILMP0 DILMP ( VDC RDC) or motor starter MSC- ( VDC). Use of the standard switchgear of the xstart range. Use of the standard accessories in the xstart range. Suitable for contactor combinations with PKZ or with Z overload relays. Integrated switch position scanning. Integrated mechanical switch position indication. Contactor actuation. SWD diagnostics LED for signalling the communication status of the modules and signalling of the switch command via. Two digital inputs for scanning floating contacts, such as motor-protective circuit-breaker auxiliary contacts. For DIL-SWD--00 built-in Manual/ Auto functionality for automatic or manual switching on of the connected contactor. Connection to ribbon cable via device plug. SWD input/output modules Page / Digital module with four V DC digital inputs and two relay outputs for actuating contactors DILM0-DILM7. Connection to through device plug. Link for device plug Page /7 Connection to device plug. Suitable for the bridging of already adapted device plugs (e.g. as a placeholder). Planning and ordering help (SWD assist) Easy generation of applications with the system. Integrated function for the generation of ordering lists. Integrated plausibility check. Online functionality. Simple preliminary commissioning of inputs and outputs and function testing. Simple diagnostics of SmartWire- Darwin slaves. Free download under Safety engineering Emergency-stop disconnection to IEC/EN 9-, switching category ; EN ISO 89- PL d; IEC 0 SIL Central switch off of the control voltage at the gateway or power feeder module. Combination with safety-related switchgears possible. Design note The number of motor starters or DILM contactors that can be connected is dependent upon the power consumption of the magnet systems per SmartWire Darwin line. To increase the number of modules that can be connected power feeder modules can be used. V DC DILM(C)7, DILA DILM(C)9 DILM(C), DILMP0 Pick-up power [W] Holding power [W] DILM(C) DILM(C)7 DILM(C) DILM(C), DILMP DILM8, DILMP 00 CA08000Z-EN

15 / Darwin Technology SWD contactor modules, SWD PKE module HPL00EN SWD contactor modules, SWD PKE module Ordering Description For use with Part no. Article no. Price See price list Std. pack SWD contactor modules ) module for surface-mounting on contactors. Per contactor module. Two digital inputs for floating contacts. electrical interlock for the surface mounting of reversing starters. Messages: contactor switch status, status of the digital inputs and. Commands: contactor actuation DILM(C)7 - DILM(C) DILM8 DILA MSC-D(E)-...(VDC) DIL-SWD off Two digital inputs for floating contacts. electrical interlock for the surface mounting of reversing starters. -0-A switch for manual or automatic operation. Messages: contactor switch status, status of the digital inputs and, switch position -0-A switch. Commands: contactor actuation DILM(C)7 - DILM(C) DILM8 DILA MSC-D(E)-...(VDC) DIL-SWD off SWD PKE module )) module for connection of motor starter combination, model extended V DC (MSC-DEA- ) up to kw. One module per contactor and PKE. Surface-mounting to contactors. Interface for connection of PKE trip block PKE-XTUA- Connecting cable between module and trip block PKE-XTUA- included as standard. electrical interlock for the surface mounting of reversing starters. -0-A switch for manual or automatic operation. Selectable overload relay function (ZMR) for disconnecting the contactor on overload. Messages: - Switch position contactor/pke/-0-a switch - Motor current in % - Thermal motor image in % - Trip-indicating auxiliary contact (overload, short-circuit,...) - Set value of overload release - Set value of time lag (CLASS), type of trip block Commands: contactor actuation, activation of overload relay function (ZMR) DILM(C)7 - DILM(C) MSC-DEA PKE-SWD- 89 off Notes ) Take into account the max. current consumption of the contactor coils per line. A connections must not be bridged. Wiring sets DILM -XRL and PKZM0-XRM cannot be used. Connection terminals for electrical interlocking are not suitable for safety technology. ) Additional SWD contactor module required fir actuation of reversing starter. Information relevant for export to North America NA Certification Request filed for UL and CSA UL/CSA approval applied for 00 CA08000Z-EN

16 HPL00EN Soft starters System overview Darwin Technology Soft starters / DS7 smartwire-darwin soft starters SWD ribbon cable SWD device plug Short description The DS7- -D soft starters are designed for connection to. These two-phase-controlled soft starters control three-phase motors for applications with normal operating frequency in the to 00 A rating range (. to 0 kw at 00 V mains voltage). Due to Eaton s special control method the true running behavior of a DS7 can be compared with that of three-phase soft starters. provides a direct connection to the DS7 without control signal wiring. Through the PLC transmits all control signals directly to the soft starter. The device data are available for processing in the master controller without any additional requirements. The connection with is fast, easy, inexpensive and convenient. Note: For further details see section Soft starters Ordering Rated Assigned motor rating operational current of the soft starter 00 V 80 V 0 V I e P P P A kw HP HP Part no. Article no. Price See price list Std. pack Information relevant for export to North America Soft starters Soft starters for three-phase loads, mains supply voltage 0 80 V AC (0/0 Hz) Rated control circuit voltage U c : V DC. DS7-DSX00N0-D 9 7 DS7-DSX007N0-D 9 9 DS7-DSX009N0-D DS7-DSX0N0-D DS7-DSX0N0-D 98 DS7-DSX0N0-D DS7-DSX0N0-D 90 off Product Standards IEC/EN 097--; GB 08.; UL 08; CSA-C. No 0-M9; CSA-C. No -0 CE marking NA Certification Request filed for UL and CSA Suitable for Branch circuits Max. Voltage Rating 80 V Degree of Protection IP0; UL/CSA Part no. 0 0 DS7-DSX0N0-D DS7-DSX0N0-D DS7-DSX070N0-D DS7-DSX08N0-D DS7-DSX00N0-D DS7-DSXN0-D DS7-DSX0N0-D DS7-DSX00N0-D CA08000Z-EN

17 / Darwin Technology SWD interface for NZM circuit-breakers HPL00EN SWD interface for NZM circuit-breakers System overview NZM circuit-breakers Connection cable from NZM to NZMX-SWD-70 NZM interface for Smart-Wire-Darwin SWD ribbon cable SWD device plug Short description The NZM interface module implements the data connection between circuitbreakers NZM// with electronic release and. It transmits the following digital status data: On-Off-Tripped Load warnings Reason for last trip Actual currents, the switch type and the current settings of the rotary coding switches. The switch can also be operated with a remote operator. Note: For further details see section NZM circuit-breakers. Ordering Description Part no. Article no. Price See price list Std. pack Notes NZM interface to The module implements the data connection between the NZM// with electronic release and the. The following data is transmitted: Digital status data (ON/OFF/TRIPPED) Load warnings Reason for last trip The actual currents The switch type The current settings of the rotary coding switches The switch can also be operated with a remote operator. Two digital inputs for the switch status Two transistor outputs for remote operation Retentive memory for energy data (kwh) Energy data is transmitted through digital input (S 0 ) from an external energy measuring module NZN...-XMC-SO. NZM-XSWD-70 0 off A connection cable to the circuit-breaker is included as standard. 00 CA08000Z-EN

18 HPL007EN Darwin Technology Accessories /7 Accessories Description Part no. Article no. Price See price list Std. pack Information relevant for export to North America Ribbon cable, 8 pole For laying the network inside the control panel. Length: 00 m SWD-8SF SWD-8S SWD-8SF Device plug Device plug for connecting slaves Length: m Prefabricated with blade terminals SWD-8MF. Length: m Prefabricated with blade terminals SWD-8MF. Length: 0 m Prefabricated with blade terminals SWD-8MF. SWD-00LF8-0 SWD-LF8--S 07 SWD-LF8--S 08 SWD-0LF8--S 09 SWD-8SF- 0 off NA Certification Request filed for UL and CSA off UL/CSA approval applied for off off 0 off NA Certification Request filed for UL and CSA UL/CSA approval applied for Link Bridging open mounting locations for device plugs Link for device plug SWD-8SF- SWD-SEL8-0 0 off NA Certification Request filed for UL and CSA UL/CSA approval applied for Blade terminal 8 pole blade terminal for connection to gateway, power feeder module, coupling, network termination SWD-8MF 0 0 off NA Certification Request filed for UL and CSA UL/CSA approval applied for Coupler SWD-8SFF- Coupling for 8 pole blade terminal SWD-8SFF- 0 off NA Certification Request filed for UL and CSA UL/CSA approval applied for + V Network terminator SWD-RC8-0 Network terminator for 8 pole ribbon cable SWD-RC off NA Certification Request filed for UL and CSA UL/CSA approval applied for + V Cable adapter V Cable adapter for flat cable (plug) to round cable (terminal) SWD-8FRF-0 77 off NA Certification Request filed for UL and CSA UL/CSA approval applied for Switch cabinet bushing Transition from SWD ribbon cable to round cable, can be plugged-in on both sides. Additional control voltage feeder for the motor starters and contactors. Suitable for wall thickness up to mm. Protection type IP7, drill hole 8. mm. Connection of ribbon cable with blade terminal SWD-8MF 8 pole Connection round cable via socket. Connection round cable via plug. SWD-SFL SWD-SML8-0 8 off NA Certification Request filed for UL and CSA off UL/CSA approval applied for 00 CA08000Z-EN

19 /8 Darwin Technology Accessories HPL008EN Description Part no. Article no. Price See price list Std. pack Information relevant for export to North America Round cable, 8 pole For laying the network outside of the control panel. Length: 0 m, HK-SO-LiYY, 8 mm diameter SWD-0LR8-00 off NA Certification Request filed for UL and CSA UL/CSA approval applied for Housing bushing socket Enclosure bushing for installation in surface mounting enclosure M-I... 8 pole socket/plug, IP7, for connection to SWD-S(M,F) prefabricated cables for connection to PCB M-SWD-I... 8 pole socket, M0 SWD-SF8-0 0 off NA Certification Request filed for UL and CSA UL/CSA approval applied for 8 pole plug, M0 SWD-SM8-0 0 off Connectors for SWD round cables 8 pole socket, straight SWD-SF pole plug, straight SWD-SM pole socket, 90 angled SWD-SF8-7W 0 off NA Certification Request filed for UL and CSA UL/CSA approval applied for off off 8 pole plug, 90 angled SWD-SM8-7W 0 off Tools for plugs Pliers for device plugs SWD-CRP- 0 off UL/CSA certification not required Pliers for blade terminal SWD-CRP- 99 off Insert for toggle lever press of device plugs SWD-CRPAD- 700 off Insert for toggle lever press of blade terminal SWD-CRPAD- 70 off 00 CA08000Z-EN

20 Power consumption/current consumption V SWD control voltage U AUX DIL-SWD-- PKE-SWD- Darwin Technology Current consumption SWD slaves /9 HPL009EN Current consumption SWD slaves Engineering Current consumption V SWD supply voltage Part no. Article no. Current consumption Notes ma M-SWD-K M-SWD-K M-SWD-LED-W M-SWD-LED-B M-SWD-LED-G M-SWD-LED-R M-SWD-KLED-W M-SWD-KLED-B M-SWD-KLED-G M-SWD-KLED-R M-SWD-KLED-W M-SWD-KLED-B M-SWD-KLED-G M-SWD-KLED-R M-SWD-KC M-SWD-KC M-SWD-LEDC-W M-SWD-LEDC-B M-SWD-LEDC-G M-SWD-LEDC-R M-SWD-KLEDC-W M-SWD-KLEDC-B M-SWD-KLEDC-G M-SWD-KLEDC-R M-SWD-KLEDC-W M-SWD-KLEDC-B M-SWD-KLEDC-G M-SWD-KLEDC-R DIL-SWD DIL-SWD PKE-SWD EUE-SWD-8DX 8 - EUE-SWD-DD 8 - EUE-SWD-DR 8 - NZM-XSWD M-SWD-I-LP With terminating resistor switched on M-SWD-I-LP M-SWD-I-LP M-SWD-I-LP M-SWD-I-LP SWD-RC Pick-up power for DILM(C) 7-9, DILA W for DILM(C) -, DILMP0 W.. for DILM(C) 7-8, DILMP- W Pick-up current for DILM(C) 7-9, DILA ma for DILM(C) -, DILMP0 ma for DILM(C) 7-8, DILMP- ma Sealing power for DILM(C) 7-9, DILA W for DILM(C) -, DILMP0 W.. for DILM(C) 7-8, DILMP- W Sealing current for DILM(C) 7-9, DILA ma for DILM(C) -, DILMP0 ma for DILM(C) 7-8, DILMP- ma SWD gateways, power feeder modules 00 CA08000Z-EN

21 /0 Darwin Technology SWD gateways, power feeder modules Technical data EUC-SWD-DP EUC-SWD-CAN EUC-SWD-PF- EUC-SWD-PF- General Standards IEC/EN - Dimensions (W x H x D) mm x 90 x 7 x 90 x Weight kg Weight g Mounting Top-hat rail IEC/EN 07, mm Mounting position Vertical Ambient mechanical conditions Protection type (IEC/EN 09, EN078, VBG ) IP0 IP0 IP0 IP0 Vibrations (IEC/EN -:008) Constant amplitude. mm Hz Constant acceleration, g Hz Mechanical shock resistance (IEC/EN ) Shocks semi-sinusoidal g/ ms Drop to IEC/EN Drop mm height Free fall, packaged (IEC/EN 008--) m Electromagnetic compatibility (EMC) Overvoltage category II II II II Pollution degree Electrostatic discharge (IEC/EN -:008) Air discharge (Level ) kv Contact discharge (Level ) kv Electromagnetic fields (IEC/EN -:008) MHz V/m GHz V/m -.7 GHz V/m Radio interference suppression () EN 0 Class A Burst (IEC/EN -:008, Level ) Supply cables kv CAN/DP bus cable kv cables kv Surge (IEC/EN -:008, Level ) Supply cables/can/dp bus cable Supply cables 0. kv, CAN/DP bus cable kv 0 Radiated RFI (IEC/EN -:008, Level ) V Ambient climatic conditions Operating ambient temperature (IEC 008-) C Condensation Prevent with suitable measures Storage C Relative humidity, non-condensing (IEC/EN ) % Supply voltage U Aux Rated operating voltage V DC -% +0% Input voltage residual ripple % Protection against polarity reversal Yes Yes Yes Yes Max. current I max A If contactors with a total power consumption > A are connected, a power feeder module EUC-SWD-PF/ has to be used. Short-circuit rating no, external fuse FAZ Z Heat dissipation W Normally Normally Normally Normally Potential isolation No No No No Rated operating voltage of V DC stations V Normally U Aux - 0. Normally U Aux - 0. Normally U Aux - 0. Normally U Aux CA08000Z-EN

22 Darwin Technology SWD gateways, power feeder modules / EUC-SWD-DP EUC-SWD-CAN EUC-SWD-PF- EUC-SWD-PF- Supply voltage U Pow Supply voltage V DC - % + 0 % DC - % + 0 % DC - % + 0 % Input voltage residual ripple % Protection against polarity reversal Yes Yes Yes Rated operational current I A Overload proof Yes Yes Yes Inrush current and length A. A/ ms. A/ ms. A/ ms Heat dissipation at V DC W Potential isolation between U Pow and V No No Yes supply voltage Bridging voltage dips ms Repeat rate s Status indicator LED Yes Yes Yes Provision of supply voltage Rated operational voltage U e V. ± %. ± %. ± % Max. current I max A If SWD modules with a total power consumption > 0.7 A are connected, a power feeder module EUC-SWD-PF has to be used. Short-circuit rating Yes Yes Yes Connection supply voltages Terminal type Push-in terminals Solid mm (AWG - ) Flexible with ferrule mm network Station type master Number of slaves 8 99 Baud rate kbd Address setting Automatic Automatic Status indicator LED master LED: green Configuration LED: red Connections Plug, 8 pole x plug, 8 pole Plug connectors Blade terminal SWD-8MF blade terminals SWD-8MF Fieldbus interface Function PROFIBUS-DP slave CANopen slave Bus protocol PROFIBUS-DP CANopen Baud rate Up to MB Up to MB Baud rate detection Automatic Automatic Station address Address setting DIP switches DIP switches Status indication of fieldbus interface LED Two-colored red/ Two-colored red/ green green Terminal resistor Switchable via plug DIP switches Terminal type fieldbus x SUB-D, 9 pole, socket x SUB-D plug, 9 pole Potential isolation Yes Yes 00 CA08000Z-EN

23 / Darwin Technology SWD input/output modules SWD input/output modules EUE-SWD-8DX EUE-SWD-DD EUE-SWD-DR General Standards IEC/EN - Dimensions (W x H x D) mm x 90 x 0 Weight kg Mounting Top-hat rail IEC/EN 07, mm Mounting position Vertical Ambient mechanical conditions Protection type (IEC/EN 09, EN078, VBG ) IP0 IP0 IP0 Vibrations (IEC/EN -:008) Constant amplitude. mm Hz Constant acceleration, g Hz Mechanical shock resistance (IEC/EN ) Shocks semi-sinusoidal g/ ms Drop to IEC/EN Drop mm height Free fall, packaged (IEC/EN 008--) m Electromagnetic compatibility (EMC) Overvoltage category II II II Pollution degree Electrostatic discharge (IEC/EN -:008) Air discharge (Level ) kv Contact discharge (Level ) kv Electromagnetic fields (IEC/EN -:008) MHz V/m GHz V/m -.7 GHz V/m Radio interference suppression () EN 0 Class A Burst (IEC/EN -:008, Level ) Supply cables kv Signal cables kv cables kv Surge (IEC/EN -:008, Level ) Supply cables 0. kv Radiated RFI (IEC/EN -:008, Level ) V Ambient climatic conditions Operating ambient temperature (IEC 008-) C Condensation Prevent with suitable measures Storage C Relative humidity, non-condensing (IEC/EN ) % network Station type station (slave) Baud rate detection Automatic status LED Green Connection Plug, 8 pole Connection plug: Device plug SWD-8SF- Current consumption ( V SWD supply) Page 9 Connection supply and I/O Terminal type Push-in terminals Solid mm (AWG - ) Flexible with ferrule mm Minimum length 8 mm V DC supply for output supply Rated operational voltage U e V DC - % / +0 % Input voltage residual ripple % Protection against polarity reversal Yes 00 CA08000Z-EN

24 Darwin Technology SWD input/output modules / EUE-SWD-8DX EUE-SWD-DD EUE-SWD-DR Digital inputs Number 8 Input current ma Normally at V DC Voltage level to IEC/EN - Limit value type Low < V DC; High > V DC Input delay High Low typ. < 0. ms Low High typ. < 0. ms status LED Yellow Digital semiconductor outputs Number Output current A Normally 0. at V DC Short-circuit tripping current A Max.. over ms Lamp load R LL W Overload proof Yes, with diagnostics Switching capacity EN utilization category DC- Relay outputs Number Contact type Normally open contact Operations Utilization category AC-, 0 V, A > x 0 Utilization category AC-, 0 V, A > x 0 Utilization category DC-, V, A > x 0 Safe isolation according to V AC 0 Minimum load current ma 00 ma, V DC Response/reset time ms /. Bounce duration ms Normally. Short-circuit protection External A gl/gg Status display outputs LED Yellow Yellow Potential isolation Inputs from Yes Yes Yes Semi-conductor outputs from Yes Semi-conductor outputs from inputs No Relays from Yes Relays from inputs Yes Relays from relays Yes 00 CA08000Z-EN

25 / Darwin Technology SWD RMQ connections Darwin Technology SWD RMQ connections / SWD RMQ connections M-SWD-K M-SWD-KC M-SWD-LED- M-SWD-LEDC- M-SWD-K-LED M-SWD-KLEDC- M-SWD-K M-SWD-KC M-SWD-K-LED M-SWD-KLEDC- General Standards IEC/EN - IEC/EN - IEC/EN - Dimensions (W x H x D) mm x x 9 x x 7 0 x x 0 x x x x x x 7 x x 9 7 x x 7 7 x x 7 x x Weight g Mounting position Any Any Any Any Any Any Any Any Any Any Ambient mechanical conditions Protection type (IEC/EN 09, EN078, VBG ) IP0 IP0 IP0 IP0 IP0 IP0 IP0 IP0 IP0 IP0 Vibrations (IEC/EN -:008) Constant amplitude. mm Hz Constant acceleration, g Hz Mechanical shock resistance (IEC/EN ) Shocks semi-sinusoidal g/ ms Drop to IEC/EN Drop mm height Free fall, packaged (IEC/EN 008--) m Electromagnetic compatibility (EMC) Overvoltage category Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable Pollution degree Electrostatic discharge (IEC/EN -:008) Air discharge (Level ) kv Contact discharge (Level ) kv Electromagnetic fields (IEC/EN -:008) MHz V/m GHz V/m -.7 GHz V/m Radio interference suppression () EN 0 Class A EN 0 Class A EN 0 Class A EN 0 Class A EN 0 Class A EN 0 Class A EN 0 Class A EN 0 Class A EN 0 Class A EN 0 Class A Burst (IEC/EN -:008, Level ) Supply cables kv cables kv Radiated RFI (IEC/EN -:008, Level ) V Ambient climatic conditions Operating ambient temperature (IEC 008-) C Condensation Prevent with suitable measures Prevent with suitable measures Storage C Relative humidity, non-condensing (IEC/EN ) % network Station type station (slave) station (slave) Number Baud rate setting Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic Automatic status LED Green Green Green Green Green Green Green Green Green Green Connections Plug, 8 pole Plug, 8 pole Plug, 8 pole Plug, 8 pole Plug, 8 pole Plug, 8 pole Plug, 8 pole Plug, 8 pole Plug, 8 pole Plug, 8 pole Plug connectors SWD-8SF- M-SWD-I LP SWD-8SF- M-SWD-I LP SWD-8SF- M-SWD-I LP SWD-8SF- M-SWD-I LP SWD-8SF- M-SWD-I LP Number of insertion cycles Current consumption ( V SWD supply) Page 9 Page 9 Function element Contacts changeover contact changeover contact IEC/EN - IEC/EN - changeover contact Lifespan mechanical/electrical Switch operations x 0 x 0 x 0 x 0 x 0 x 0 x 0 x 0 LED display LED No No Yes Yes Yes Yes No No Yes Yes Diagnostics Yes Yes No No Yes Yes Yes Yes Yes Yes Fixing Front fixing Base fixing Front fixing Base fixing Front fixing Base fixing Front fixing Base fixing Front fixing Base fixing IEC/EN - changeover contact IEC/EN - changeover contacts IEC/EN - changeover contacts IEC/EN - changeover contacts IEC/EN - changeover contacts 00 CA08000Z-EN 00 CA08000Z-EN

26 / Darwin Technology SWD DIL module, SWD PKE module, SWD NZM interface SWD DIL module, SWD PKE module, SWD NZM interface DIL-SWD--00 DIL-SWD--00 PKE-SWD- NZM-XSWD-70 General Standards IEC/EN - IEC/EN 097 Dimensions (W x H x D) mm x 8 x 7 x 8 x 7 x 8 x 7 x 90 x 0 Weight kg Mounting on DILM7 DILM8 on DILM7 DILM8 on DILM7 DILM Top-hat rail I EC/EN 07, mm Mounting position as DILM7 DILM8 as DILM7 DILM8 as DILM DILM Vertical Ambient mechanical conditions Protection type (IEC/EN 09, EN078, IP0 IP0 IP0 IP0 VBG ) Vibrations (IEC/EN -:008) Constant amplitude. mm Hz Constant acceleration, g Hz Mechanical shock resistance Shocks (IEC/EN ) semi-sinusoidal g/ ms Drop to IEC/EN Drop mm height Free fall, packaged (IEC/EN 008--) m Electromagnetic compatibility (EMC) Overvoltage category II II II II Pollution degree Electrostatic discharge (IEC/EN -:008) Air discharge (Level ) kv Contact discharge (Level ) kv Electromagnetic fields (IEC/EN -:008) MHz V/m GHz V/m -.7 GHz V/m Radio interference suppression EN 0 Class A EN 0 Class A EN 0 Class A EN 0 Class A () Burst (IEC/EN -:008, Level ) Supply cables kv CAN/DP bus cable kv cables kv Radiated RFI (IEC/EN -:008, Level ) V Ambient climatic conditions Operating ambient temperature (IEC 008-) Condensation C Prevent with suitable measures Prevent with suitable measures Prevent with suitable measures Storage C Relative humidity, non-condensing % (IEC/EN ) network Station type station (slave) station (slave) station (slave) Prevent with suitable measures station (slave) Address setting Automatic Automatic Automatic Automatic Status LED Green/orange Green/orange Green/orange Green Connections Plug, 8 pole Plug, 8 pole Plug, 8 pole Plug, 8 pole Plug connectors Device plug SWD-8SF- Device plug SWD-8SF- Device plug SWD-8SF- Device plug SWD-8SF- Current consumption ( V SWD supply) Page 9 00 CA08000Z-EN

27 Darwin Technology SWD DIL module, SWD PKE module, SWD NZM interface /7 DIL-SWD--00 DIL-SWD--00 PKE-SWD- NZM-XSWD-70 Operation mode Manual/automatic mode No Yes Yes Setting Rotary switch Rotary switch Connection auxiliary contact Number Rated voltage U e V DC Self-supplied Self-supplied Input current at signal, typical ma Potential isolation No No Cable length m.8.8 Terminal type Push-in terminals Push-in terminals Push-in terminals Terminal capacity Solid mm (AWG - ) (AWG - ) (AWG - ) (AWG - ) Flexible with ferrule mm Minimum length 8 mm Minimum length 8 mm Minimum length 8 mm Minimum length 8 mm 00 CA08000Z-EN

28 /8 Darwin Technology Accessories Darwin Technology Accessories /9 Accessories Part no. SWD-RC8-0 SWD-8SF- SWD-8SFF- SWD-SF8-0 SWD-SM8-0 SWD-8FRF-0 SWD-SFL8-0 SWD-SML8-0 General Standards IEC/EN - IEC/EN - IEC/EN - Dimensions (W x H x D) mm 8. x. x 0 x. x x. x 0 x x x x 70 x 90 x x 8 x 0 x 8 x Weight kg Weight g Mounting position Any Any Any Any Any Any Any Any Ambient mechanical conditions Protection type (IEC/EN 09, EN078, VBG ) IP0 IP0 IP0 IP7 IP7 IP0 IP7 IP7 Vibrations (IEC/EN -:008) Constant amplitude. mm Hz Constant acceleration, g Hz Mechanical shock resistance (IEC/EN ) Shocks semi-sinusoidal g/ ms Drop to IEC/EN Drop mm 0 height Free fall, packaged (IEC/EN 008--) m 0. Electromagnetic compatibility (EMC) Overvoltage category II Pollution degree Electrostatic discharge (IEC/EN -:008) Air discharge (Level ) kv Contact discharge (Level ) kv Electromagnetic fields (IEC/EN -:008) MHz V/m GHz V/m -.7 GHz V/m Radio interference suppression () EN 0 Class A Burst (IEC/EN -:008, Level ) cables kv Radiated RFI (IEC/EN -:008, Level ) V Ambient climatic conditions Operating ambient temperature (IEC 008-) C Condensation Prevent with suitable measures Prevent with suitable measures Prevent with suitable measures Prevent with suitable measures Prevent with suitable measures Prevent with suitable measures Prevent with suitable measures Prevent with suitable measures Storage C Relative humidity, non-condensing (IEC/EN ) % Connection options SWD-In Plug, 8 pole Plug connector Plug, 8 pole Plug, 8 pole Plug, 8 pole Plug, 8 pole Plug, 8 pole Number of insertion cycles SWD-Out Socket, 8 pole Plug, 8 pole Socket, 8 pole Push-in terminals Socket, 8 pole Plug, 8 pole Number of insertion cycles Current consumption ( V SWD supply) Page 9 Page 9 IEC/EN - IEC/EN - IEC/EN - IEC/EN - IEC/EN - 00 CA08000Z-EN 00 CA08000Z-EN

29 /0 Darwin Technology SWD RMQ connections SWD RMQ connections Dimensions SWD gateways, input/output module, power feed modules EUC-SWD-DP 90 a EUC-SWD-DP EUC-SWD-CAN EUE-SWD EUC-SWD-PF... 0 SWD contactor modules DIL-SWD--00 DIL-SWD--00 a SWD PKE module PKE-SWD Fixing adapter (front fixing) for -contact/led elements Function elements M-A- M-SWD-A M-SWD-K... M-SWD-LED a a M-A M-SWD-A SWD soft starter DS7 DS7-DSX Dimension Chapter "Soft starter" SWD interface for NZM circuit-breakers Dimensions Chapter " NZM Circuit-breakers" 00 CA08000Z-EN

30 Darwin Technology Accessories / Accessories Device plug Network terminator Coupler SWD-8SF- SWD-RC8-0 SWD-8SFF Housing bushing plug Housing bushing socket SWD-SM8-0 SWD-SF8-0 Ø. M0 x. Ø M0 x. Switch cabinet bushing plug Switch cabinet bushing socket SWD-SM8-0 SWD-SFL M8 x Adapter for blade terminal to round cable Plug connector for SWD round cables, straight SWD-8FRF-0 SWD-SF8-7 SWD-SM o 8. M8 x Plug connector for SWD round cables, angled SWD-SF8-7W SWD-SM8-7W o o 8 o 8. M x 0.7 M x M x CA08000Z-EN

New Products Catalogue SmartWire-Darwin. The easy way to connect. The easy way to connect.

New Products Catalogue SmartWire-Darwin. The easy way to connect. The easy way to connect. Darwin Technology www.moeller.net New Products Catalogue 2009 The easy way to connect. The easy way to connect. . Evolution in the control panel. Controlling Manufacturers of machines and systems strive

More information

Connectivity Solutions

Connectivity Solutions SmartWire-DT.1 System Overview Product Description.................................... Features............................................. System Overview Diagram............................... System

More information

Connectivity Solutions

Connectivity Solutions SmartWire-DT.1 System Overview Product Description.................................... Features............................................. System Overview Diagram............................... System

More information

Connectivity Solutions. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents.

Connectivity Solutions. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents. .1 Connectivity Solutions Contents Description System Components.................... Contactor Modules..................... Pilot Device Modules.................... Technical Data and Specifications..........

More information

9.1. Connectivity Solutions

9.1. Connectivity Solutions .1 Pilot Device Modules Contents Description System Components....................... System Controllers........................ Contactor Modules........................ Pilot Device Modules Product Identification....................

More information

The easy way to connect. Product Information. SmartWire-Darwin. The cost-optimised communication system for switchgear

The easy way to connect. Product Information. SmartWire-Darwin. The cost-optimised communication system for switchgear Darwin Technology www.moeller.net/darwin The easy way to connect. Product Information SmartWire-Darwin The cost-optimised communication system for switchgear SmartWire-Darwin. Cost-optimized communication

More information

Solutions from Lean Connectivity to Lean Automation. The easy way to connect. Cost Optimization Clever Communication

Solutions from Lean Connectivity to Lean Automation. The easy way to connect. Cost Optimization Clever Communication Solutions from Lean Connectivity to Lean Automation The easy way to connect. Cost Optimization Clever Communication SmartWire-DT. From Lean Connectivity to Lean Automation. Controlling Lean Connectivity

More information

SmartWire-Darwin Units

SmartWire-Darwin Units User Manual 05/10 MN05006001Z-EN SmartWire-Darwin Units All brand and product names are trademarks or registered trademarks of the owner concerned. Emergency On Call Service Please call your local representative:

More information

Manual. 05/11 MN Z-EN replaces AWB en. SmartWire-DT Units

Manual. 05/11 MN Z-EN replaces AWB en. SmartWire-DT Units Manual 05/11 MN05006001Z-EN replaces AWB2723-1613en SmartWire-DT Units All brand and product names are trademarks or registered trademarks of the owner concerned. Emergency On Call Service Please call

More information

002 Easy Control Relays System Overview

002 Easy Control Relays System Overview 002 Easy Control System Overview 1 1 3 2 4 3 5 7 6 5 8 6 7 9 Easy Control System Overview 003 Basic units 1 AC or DC operated Power supply AC 100 (115) 240 V, 50/60 Hz DC 24 V DC DA 12 V DC 8 or 12 digital

More information

Manual 05/15 MN Z-EN. SmartWire-DT modules

Manual 05/15 MN Z-EN. SmartWire-DT modules Manual 05/15 MN05006001Z-EN SmartWire-DT modules All proprietary names and product designations are brand names or trademarks registered to the relevant title holders. Break-Down Service Please call your

More information

SmartWire-Darwin The System

SmartWire-Darwin The System User Manual 06/10 SmartWire-Darwin The System Controlling Protecting HMI Switching Drives All brand and product names are trademarks or registered trademarks of the owner concerned. Emergency On Call Service

More information

Switching, control, visualization

Switching, control, visualization Eaton Wiring Manual 0/ Page SmartWire-DT communication system - The way to the safe machine -9 Timing relays - EMR measuring and monitoring relays -0 System overview Relay, MFD-Titan - Engineering Relay,

More information

Revolutionizing control wiring

Revolutionizing control wiring SmartWire-DT Panel Wiring Solutions Revolutionizing control wiring 797-6925 Fax: (215) 221-1201 www.royalelectric.com SmartWire-DT Changing the way panels are wired. Reduce cost throughout the value chain.

More information

Go to: 01/001. Contents EASY Control Relay. Page System overview 01/002

Go to:  01/001. Contents EASY Control Relay. Page System overview 01/002 DEL ALT Contents 01/001 ESC OK Page System overview 01/002 Description EASY800 networking 01/006 EASY control relay Basic units 01/007 Expansion units 01/009 Accessories 01/010 Technical data 01/012 Dimensions

More information

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA Delivery program Contactor relay, 3N/O+1N/C, DC current Part no. DILA-31(24VDC) Catalog No. 276379 Eaton Catalog No. XTRE10B31TD EL-Nummer 4130206 (Norway) Product range DILA relays Application Contactor

More information

Solutions from Lean Connectivity to Lean Automation. The easy way to connect. Cost Optimization Clever Communication

Solutions from Lean Connectivity to Lean Automation. The easy way to connect. Cost Optimization Clever Communication Solutions from Lean Connectivity to Lean Automation The easy way to connect. Cost Optimization Clever Communication Lean Solution powered by SmartWire-DT The Lean-Philosophie The requirements of the machine

More information

EasyConnect SmartWire

EasyConnect SmartWire EasyConnect SmartWire Seite - 1 Darwin Evolution in panel building Seite - 2 Darwin Control Drives easyconnect Motor starter MCCB Command and indication Seite - 3 Less wiring by moving the I/O to the contactor

More information

The simplicity of it! Tool-less plug connection without tools!

The simplicity of it! Tool-less plug connection without tools! The simplicity of it! Tool-less plug connection without tools! Using the new xstart motor-starter combinations it is possible to create the best solutions from standard products even more easily and efficiently.

More information

Contact protection relay

Contact protection relay Contact protection relay Ordering details SVR 450 08 F0000 The protects sensitive control contacts from excessive load. It can be used with latching function or without. Bounce time of control contacts

More information

4/0 EASY control relay

4/0 EASY control relay 4/0 DEL ALT ESC OK Contents 4/1 Page System overview 4/2 4/4 EASY800 networking 4/4 4/5 Basic units 4/5 Expansion units 4/9 Multi-function display 4/8 Display/operator unit 4/8 Power supply/cpu modules

More information

Connection System SmartWire Module

Connection System SmartWire Module Connection System SmartWire Module Hardware and Function Description 11/06 AWB1210+1251-1591GB AWe keep power under control. All brand and product names are trademarks or registered trademarks of the owner

More information

SmartWire-DT In panel and on machine wiring solutions. Revolutionizing in-panel control wiring and on-machine connection of sensors and actuators

SmartWire-DT In panel and on machine wiring solutions. Revolutionizing in-panel control wiring and on-machine connection of sensors and actuators SmartWire-DT In panel and on machine wiring solutions Revolutionizing in-panel control wiring and on-machine connection of sensors and actuators SmartWire-DT Changing the way panels... Reduce cost throughout

More information

Reliable Switchgear from One Proven Supplier

Reliable Switchgear from One Proven Supplier Catalogue Industrial Switchgear 2007/2008 Reliable Switchgear from One Proven Supplier Xtra Combinations Xtra Combinations from Moeller offers a range of products and services, enabling the best possible

More information

Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A DATASHEET - PKZM4-25 Delivery program Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection Part no. PKZM4-25 Catalog No. 222352 Eaton Catalog No. XTPR025DC1NL EL-Nummer 0004355158 (Norway)

More information

Safety relay emergency stop/protective door, 24VDC/AC, 4 enabling paths

Safety relay emergency stop/protective door, 24VDC/AC, 4 enabling paths DATASHEET - ESR5-NO-41-24VAC-DC Safety relay emergency stop/protective door, 24VDC/AC, 4 enabling paths Part no. ESR5-NO-41-24VAC-DC Catalog No. 118701 EL-Nummer (Norway) 0004133317 Delivery program Product

More information

Installation / Control Technique

Installation / Control Technique Installation / Control Technique Interface Relay, Interface Relay System Input-Output Interface Relay IK 3070, I_ 3070 0633 IK 3070 Circuit Diagrams IS 3070 According to IEC/EN 61 810-1 Relay, triac or

More information

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview Supplementary Protectors / Miniature Circuit Breakers Page System overview 10/003 10/001 Supplementary protectors

More information

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input Safety + standard I/O in one module Safety relay output with galvanically isolated contact sets, approved up to 230 V IEC 61508 SIL 3, EN ISO 13849-1/PLe Kat 4, EN 62061 SIL 3 Protection category IP20

More information

SITOP in the SIMATIC Design

SITOP in the SIMATIC Design Siemens AG 2017 /2 Introduction /3 1-phase, 24 V DC (for S7-300 and ET 200M) /9 1-phase, 24 V DC (for S7-1200) /11 1-phase, 24 V DC (for S7-1500 and ET 200MP) /14 3-phase, 24 V DC (ET 200pro) Siemens KT

More information

ATV930D22M3 variable speed drive - ATV930-22kW - 200/240V- with braking unit - IP21

ATV930D22M3 variable speed drive - ATV930-22kW - 200/240V- with braking unit - IP21 Characteristics variable speed drive - ATV930-22kW - 200/240V- with braking unit - IP21 Main Range of product Product or component type Device application Device short name Variant Product destination

More information

ATV650U30N4E variable speed drive ATV650-3kW V - IP55 - disconnect switch

ATV650U30N4E variable speed drive ATV650-3kW V - IP55 - disconnect switch Characteristics variable speed drive ATV650-3kW - 380...480V - IP55 - disconnect switch Main Range of product Product or component type Product specific application Device short name Variant Product destination

More information

3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017

3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017 3RM1 Hybrid Starters Industrial Controls Product Catalog 2017 Section contents 3RM1 Compact - Hybrid Starters Overview /2 General Data /3 Selection and ordering data /4 Accessories /5 - /9 Technical Data

More information

XPSMCMCO0000EM Modbus TCPIP diagnostic expansion module with screw term

XPSMCMCO0000EM Modbus TCPIP diagnostic expansion module with screw term Characteristics Modbus TCPIP diagnostic expansion module with screw term Main Range of product Product or component type Device short name [Us] rated supply voltage Complementary Power dissipation in W

More information

OTB1C0DM9LP I/O distributed module OTB - CANopen bus m

OTB1C0DM9LP I/O distributed module OTB - CANopen bus m Characteristics I/O distributed module OTB - CANopen bus - 0..1000 m Main Range of product Product or component type Integrated connection type Bus type Jan 28, 2018 Modicon OTB I/O distributed module

More information

Bulletin 817 Thermistor Protection Relay

Bulletin 817 Thermistor Protection Relay 6 Bulletin 817 Accurate Temperature Monitoring for Critical Applications Automatic, Manual and Remote Reset Status Indicating LEDs DIN Rail or Panel Mounting Guarded Terminals IP20 1 N.O. and 1 N.C. Output

More information

RTU500 series Data Sheet Power Supply CP-E 24/2.5

RTU500 series Data Sheet Power Supply CP-E 24/2.5 Data Sheet Power Supply CP-E 24/2.5 Power Supply CP-E 24/2.5 Application The primary switch mode power supply offers two voltage input ranges. This enables the supply with AC or DC. Furthermore it is equipped

More information

DC561, digital input/output module,

DC561, digital input/output module, Ordering Data DATA SHEET DC561 Digital Input/Output Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1TNE 968 902 R2001 DC561, digital input/output module, 16 configurable inputs/outputs,

More information

ATV930U30M3 variable speed drive - ATV930-3kW - 200/240Vwith braking unit - IP21

ATV930U30M3 variable speed drive - ATV930-3kW - 200/240Vwith braking unit - IP21 Characteristics variable speed drive - ATV930-3kW - 200/240Vwith braking unit - IP21 Main Range of product Product or component type Device application Device short name Variant Product destination Mounting

More information

Safety Technique. SAFEMASTER C Multifunction Safety Module BH 5910

Safety Technique. SAFEMASTER C Multifunction Safety Module BH 5910 Safety Technique SAFEMASTER C Multifunction Safety Module BH 59 47 Block Diagram A+ A S S S4 S S S S4 S S S S4 S S4 S4 S44 S4 PTC Galvanic separation Monitoring logic Monitoring logic Galvanic separation

More information

XPSMCMDI Input expansion module with screw term

XPSMCMDI Input expansion module with screw term Characteristics 16 Input expansion module with screw term Main Range of product Product or component type Device short name Electrical connection [Us] rated supply voltage Number of inputs Number of outputs

More information

Bulletin 290/291 ArmorStart LT Distributed Motor Controllers Specifications

Bulletin 290/291 ArmorStart LT Distributed Motor Controllers Specifications Power Circuit Control Circuit (External Source) Control Circuit (Internal Source) Short Circuit Current Rating (SCCR) Application Electrical Ratings Three-phase Number of Poles 3 Input Power Terminals

More information

Solid-State Contactors

Solid-State Contactors Solid-state contactors for switching motors The solid-state contactors for switching motors are intended for frequently switching on and off three-phase current operating mechanisms up to 7.5 kw and reversing

More information

XPSMCMMX inputs 2 output pairs expansion module with screw term

XPSMCMMX inputs 2 output pairs expansion module with screw term Characteristics 8 inputs 2 output pairs expansion module with screw term Main Range of product Product or component type Device short name Electrical connection [Us] rated supply voltage Number of inputs

More information

PHOENIX CONTACT - 07/2006

PHOENIX CONTACT - 07/2006 Buffer module with maintenance-free capacitor-based power storage device INTERFACE Data sheet 102035_03_en PHOENIX CONTACT - 07/2006 Description Short-term mains interruptions are bridged by QUINT BUFFER,

More information

TM241C40U controller M IO transistor NPN

TM241C40U controller M IO transistor NPN Characteristics controller M241 40 IO transistor NPN Main Range of product Product or component type [Us] rated supply voltage 15/12/2018 Modicon M241 Logic controller 24 V DC Discrete input number 24

More information

Installation / control / monitoring technique. CANopen PLC IL 5504, IN 5504 minimaster

Installation / control / monitoring technique. CANopen PLC IL 5504, IN 5504 minimaster Installation / control / monitoring technique CANopen PLC IL, IN minimaster 6 Circuit diagram CAN H Rab C CAN L C IL IN C CAN H Rab CAN L C According to IEC/EN 6 -, EN 78 Operation as master - Operation

More information

MOTUS ContactronControl. Less is more.

MOTUS ContactronControl. Less is more. MOTUS ContactronControl. Less is more. Content. MOTUS Less is more. Less wear, longer lifespan. Learn more about MOTUS at our website. 3 Our Company. Page 4. For more than 80 years, Wöhner has stood for

More information

XPSMCMDO Digital output pairs expansion modules with screw term

XPSMCMDO Digital output pairs expansion modules with screw term Characteristics 2 Digital output pairs expansion modules with screw term Main Range of product Product or component type Device short name Electrical connection [Us] rated supply voltage Number of inputs

More information

TM241C24T controller M IO transistor PNP

TM241C24T controller M IO transistor PNP Characteristics controller M241 24 IO transistor PNP Main Range of product Product or component type [Us] rated supply voltage Feb 13, 2018 Modicon M241 Logic controller 24 V DC Discrete input number 14

More information

DC562, digital input/output module,

DC562, digital input/output module, Ordering Data DATA SHEET DC562 Digital Input/Output Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 231 900 R0000 1TNE 968 901 R3101 1TNE 968 901 R3102 1TNE 968 901 R3103 1TNE

More information

OTB1C0DM9LP I/O distributed module OTB - CANopen bus m

OTB1C0DM9LP I/O distributed module OTB - CANopen bus m Characteristics I/O distributed module OTB - CANopen bus - 0..1000 m Complementary Topology Main Range of product Product or component type Integrated connection type Bus type Number of slave 0...63 Bus

More information

MINI-PS AC/10-15DC/8

MINI-PS AC/10-15DC/8 Primary-Switched Power Supply, Narrow Design Data Sheet 08/2004 MINI POWER provides: An extra narrow design, with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a

More information

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output Product datasheet Characteristics XPSMF4000 Preventa safety PLC compact - Safe Ethernet Main Range of product Product or component type Safety module name Safety module application Preventa Safety automation

More information

Installation / control / monitoring technique. CANopen PLC IL 5504, IN 5504 minimaster

Installation / control / monitoring technique. CANopen PLC IL 5504, IN 5504 minimaster Installation / control / monitoring technique CANopen PLC IL, IN minimaster 6 Circuit diagram CAN H Rab CAN H CAN CAN L GND C C CAN L C C Rab M88_a IL IN CAN H CAN H Rab CAN CAN L GND C C Rab CAN L C C

More information

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole) I cs 7,5 ka

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole) I cs 7,5 ka DATASHEET - FAZ-C16/1 Miniature circuit breaker (MCB), 16A, 1p, C-Char, AC Part no. FAZ-C16/1 Catalog No. 278561 Eaton Catalog No. FAZ-C16/1 EL-Nummer 0001695154 (Norway) Similar to illustration Delivery

More information

OTB1C0DM9LP. Main , length of segment <= 185 m , length of segment <= 160 m. 3.4 kohm for I8...I kohm I0...I1 5.7 kohm I6...

OTB1C0DM9LP. Main , length of segment <= 185 m , length of segment <= 160 m. 3.4 kohm for I8...I kohm I0...I1 5.7 kohm I6... Product datasheet Characteristics OTB1C0DM9LP Complementary Topology Number of slave 63 Bus length Number of devices per segment Discrete input voltage Discrete input voltage type Discrete input type Input

More information

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m Characteristics I/O distributed module OTB - Ethernet TCP/IP - 0..100 m Main Range of product Product or component type Integrated connection type Mar 31, 2018 Modicon OTB I/O distributed module Discrete

More information

ATV32HU11M2437 variable speed drive ATV32-1.1kW 200V - 1P - Bluetooth built-in - w heat sink

ATV32HU11M2437 variable speed drive ATV32-1.1kW 200V - 1P - Bluetooth built-in - w heat sink Characteristics variable speed drive ATV32-1.1kW 200V - 1P - Bluetooth built-in - w heat sink Main Range of product Altivar 32 Product or component type Product destination Product specific application

More information

Disconnect Switches. Safe Switching and Disconnecting

Disconnect Switches. Safe Switching and Disconnecting IB105-UK_U1_U4_Pfade.indd 2-3 14.04.2005, 16:51:30 Disconnect Switches Safe Switching and Disconnecting Disconnect Switches from Salzer are hand-operated switchgear for main circuits and are offered as

More information

Lean Line for the Machine

Lean Line for the Machine Touch Panel XV102 Solutions from Lean Connectivity to Lean Automation Lean Line for the Machine Product Information HMI/PLC XV102 with SmartWire-DT 5.7 7 widescreen 3.5 XV102 HMI/PLC Devices with Integrated

More information

Safety relay emergency stop/protective door, 230VAC, 3 enabling paths

Safety relay emergency stop/protective door, 230VAC, 3 enabling paths DATASHEET - ESR5-NO-31-230VAC Safety relay emergency stop/protective door, 230VAC, 3 enabling paths Part no. ESR5-NO-31-230VAC Catalog No. 119380 EL-Nummer (Norway) 4133320 Delivery program Product range

More information

Safety relay emergency stop/protective door, 24V-230VDC/AC, 3 enabling paths

Safety relay emergency stop/protective door, 24V-230VDC/AC, 3 enabling paths DATASHEET - ESR5-NO-31-AC-DC Delivery program Safety relay emergency stop/protective door, 24V-230VDC/AC, 3 enabling paths Part no. ESR5-NO-31-AC-DC Catalog No. 118704 Eaton Catalog No. ESR5-NO-31-AC-DC

More information

Installation / Control / Monitoring Technique

Installation / Control / Monitoring Technique Installation / Control / Monitoring Technique MINIMASTER CANopen PLC IL, IN 6 Your Advantages Compact CAN-operation Graphical programming Qquick and easy installation Various input- / output module digital

More information

XC-CPU-201 XC-CPU-201-XV

XC-CPU-201 XC-CPU-201-XV / XC-CPU- XC-CPU--XV Ethernet integrated The / MBit Ethernet interface of the XC offers the perfect link to IT communication. Whether you need rapid access to programs, high-speed data exchange between

More information

PHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

PHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area. Primary switched power supply, 3-phase, output current: 40 A INTERFACE Data Sheet 102782_01_en PHOENIX CONTACT - 06/2007 Description TRIO POWER is the rail mountable 24 V power supply unit with basic functions.

More information

DX561 Digital Input/Output Module

DX561 Digital Input/Output Module Ordering Data DATA SHEET DX561 Digital Input/Output Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1TNE 968 902 R2301 1TNE 968 901 R3101 DX561, digital input/output module, 8 DI

More information

ATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW

ATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW Characteristics soft starter for asynchronous motor - ATS01-3 A - 110..480V - 0.55..1.1 KW Complementary Assembly style Function available Power supply voltage limits Main Commercial Status Commercialised

More information

H S11I1A I2A I3A I4A I5A I6A I7A I8A S21I1C I2C I3C I4C I5C I6C I7C I8C 14A I 15A I 16A 13A I 13B 14B 15B 16B M8540

H S11I1A I2A I3A I4A I5A I6A I7A I8A S21I1C I2C I3C I4C I5C I6C I7C I8C 14A I 15A I 16A 13A I 13B 14B 15B 16B M8540 Safety technique Emergencystop monitor BH 5922, BL 5922 safemaster Profibus 34656 BH 5922 BL 5922 Circuit diagrams I3A I4A X2 I3B I4B I3A I4A I5A I6A I7A According to SILClaimed Level (SIL CL) 1 to EN

More information

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area. Primary-switched power supply for building automation INTERFACE Data sheet 103505_en_02 1 Description PHOENIX CONTACT - 08/2009 Features STEP POWER power supply units for building automation The new STEP

More information

ATSU01N209LT soft starter for asynchronous motor - ATSU01-9 A V KW

ATSU01N209LT soft starter for asynchronous motor - ATSU01-9 A V KW Characteristics soft starter for asynchronous motor - ATSU01-9 A - 200..480V - 1.5..4 KW Complementary Assembly style Function available Power supply voltage limits Main Range of product Product or component

More information

SmartWire-DT Gateways

SmartWire-DT Gateways Manual 03/11 MN05013002Z-EN replaces 06/09 AWB2723-1612en SmartWire-DT Gateways All brand and product names are trademarks or registered trademarks of the owner concerned. Emergency On Call Service Please

More information

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name Product data sheet Characteristics XPSMF3542 Preventa safety PLC compact - Profibus DP protocol Main Range of product Product or component type Safety module name Safety module application Nov 13, 2018

More information

SmartWire-DT In-panel and on-machine wiring solutions. Revolutionizing in-panel control wiring and on-machine connection of sensors and actuators

SmartWire-DT In-panel and on-machine wiring solutions. Revolutionizing in-panel control wiring and on-machine connection of sensors and actuators In-panel and on-machine wiring solutions Revolutionizing in-panel control wiring and on-machine connection of sensors and actuators Changing the way panels... Reduce cost throughout the value chain. T

More information

ATV340D75N4E variable speed drive - 75kW- 400V - 3 phases - ATV340 Ethernet

ATV340D75N4E variable speed drive - 75kW- 400V - 3 phases - ATV340 Ethernet Characteristics variable speed drive - 75kW- 400V - 3 phases - ATV340 Ethernet Main Range of product Product or component type Device application Device short name Variant Product destination Mounting

More information

TM241CE24U controller M IO transistor NPN Ethernet

TM241CE24U controller M IO transistor NPN Ethernet Characteristics controller M241 24 IO transistor NPN Ethernet Main Range of product Product or component type [Us] rated supply voltage Mar 09, 2017 Modicon M241 Logic controller 24 V DC Discrete input

More information

PHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

PHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area. Uninterruptible power supply with integrated power supply unit INTERFACE Data sheet 104211_en_00 1 Description PHOENIX CONTACT - 01/2010 Features The MINI-DC-UPS provide an uninterruptible DC voltage both

More information

1.5 Moeller series. RMQ-Titan pilot devices. System overview. M30 Flat Front System overview

1.5 Moeller series. RMQ-Titan pilot devices. System overview. M30 Flat Front System overview RMQ-Titan pilot devices.5 Moeller series M30 Flat Front System overview System overview 2 3 3 4 0 3 4 5 2 0 3 2 2 6 7 3 0 4 8 5 7 6 8 9 38 Command & Signaling CA047003EN October 206 www.eaton.eu Moeller

More information

Power supply CP-C 24/5.0

Power supply CP-C 24/5.0 2CDC 271 064 F0004 Features Supply voltage ranges: 85-264 V AC, 100-350 V DC Output voltage adjustable from 22-28 V DC, default setting 24 V DC 0,5 % 5 A output current Open-circuit, overload and continous

More information

STEP-PS/1AC/24DC/1.75

STEP-PS/1AC/24DC/1.75 Primary-switched power supply, 1 AC, output current 1.75 A INTERFACE Data Sheet 103506_en_00 1 Description PHOENIX CONTACT - 05/2008 Features STEP POWER power supply units for building automation The new

More information

1.3. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZS Circuit Breaker. UL 1077 DIN Rail Supplementary Protectors

1.3. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZS Circuit Breaker. UL 1077 DIN Rail Supplementary Protectors . Miniature Circuit Breakers and Supplementary Protectors UL 077 DIN Rail Supplementary Protectors WMZS Circuit Breakers Contents Description WMZS Circuit Breaker Standards and Certifications................

More information

TM241C40R controller M IO relay

TM241C40R controller M IO relay Characteristics controller M241 40 IO relay Main Range of product Product or component type [Us] rated supply voltage Mar 09, 2017 Modicon M241 Logic controller 100...240 V AC Discrete input number 24

More information

Miniature Circuit Breakers and Supplementary Protectors. Contents

Miniature Circuit Breakers and Supplementary Protectors. Contents . Optimum and Efficient Protection for Every Application Product Overview Features Optimum product quality, tested reliability and safety stand for best protection of personnel, installations and plant.

More information

ATS01N206RT soft starter for asynchronous motor - ATS01-6 A V

ATS01N206RT soft starter for asynchronous motor - ATS01-6 A V Characteristics soft starter for asynchronous motor - ATS01-6 A - 460..480 V Price* : 152.00 GBP Main Range of product Altistart 01 Product or component type Product destination Product specific application

More information

ATV320D11N4B variable speed drive ATV320-11kW V - 3 phase - book

ATV320D11N4B variable speed drive ATV320-11kW V - 3 phase - book Characteristics variable speed drive ATV320-11kW - 380...500V - 3 phase - book Main range of product product or component type product specific application device short name format of the drive product

More information

ATV320D15N4B variable speed drive ATV320-15kW V - 3 phase - book

ATV320D15N4B variable speed drive ATV320-15kW V - 3 phase - book Characteristics variable speed drive ATV320-15kW - 380...500V - 3 phase - book Main Range of product Product or component type Product specific application Device short name Format of the control block

More information

ATV320D15N4B variable speed drive ATV320-15kW V - 3 phase - book

ATV320D15N4B variable speed drive ATV320-15kW V - 3 phase - book Characteristics variable speed drive ATV320-15kW - 380...500V - 3 phase - book Main range of product product or component type product specific application device short name format of the drive product

More information

TM3SAC5RG SAFETY MODULE FOR PLC TM2xx, 1 FUNCTION, CAT3, SPRING TERMINALS

TM3SAC5RG SAFETY MODULE FOR PLC TM2xx, 1 FUNCTION, CAT3, SPRING TERMINALS Characteristics SAFETY MODULE FOR PLC TM2xx, 1 FUNCTION, CAT3, SPRING TERMINALS Main Range of product Product or component type Device short name Safety module application Function of module Jun 29, 2018

More information

TM241CE24T controller M IO transistor PNP Ethernet

TM241CE24T controller M IO transistor PNP Ethernet Characteristics controller M241 24 IO transistor PNP Ethernet Main Range of product Product or component type [Us] rated supply voltage Apr 10, 2018 Modicon M241 Logic controller 24 V DC Discrete input

More information

ATV320U07M2C variable speed drive ATV kW V - 1 phase - compact

ATV320U07M2C variable speed drive ATV kW V - 1 phase - compact Characteristics variable speed drive ATV320-0.75kW - 200...240V - 1 phase - compact Main Range of product Product or component type Product specific application Device short name Format of the drive Product

More information

ABL1REM24025 regulated SMPS - single phase V input - 24 V output - 60 W

ABL1REM24025 regulated SMPS - single phase V input - 24 V output - 60 W Characteristics regulated SMPS - single phase - 100..240 V input - 24 V output - 60 W Main Range of product Product or component type Power supply type Rated power in W Input voltage Output voltage Power

More information

ATV320U30N4B variable speed drive ATV320-3kW V - 3 phase - book

ATV320U30N4B variable speed drive ATV320-3kW V - 3 phase - book Characteristics variable speed drive ATV320-3kW - 380...500V - 3 phase - book Main Range of product Product or component type Product specific application Device short name Format of the control block

More information

TM241CE40T controller M IO transistor PNP Ethernet

TM241CE40T controller M IO transistor PNP Ethernet Characteristics controller M241 40 IO transistor PNP Ethernet Main Range of product Product or component type [Us] rated supply voltage 18 Nov, 2018 Modicon M241 Logic controller 24 V DC Discrete input

More information

SD328AU68S2 motion control stepper motor drive - SD328 - <= 6.8 A

SD328AU68S2 motion control stepper motor drive - SD328 - <= 6.8 A Characteristics motion control stepper motor drive - SD328 -

More information

TM241CE24T controller M IO transistor PNP Ethernet

TM241CE24T controller M IO transistor PNP Ethernet Product data sheet Characteristics TM241CE24T controller M241 24 IO transistor PNP Ethernet Complementary Main Discrete I/O number 24 Number of I/O expansion module Supply voltage limits Inrush current

More information

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D D600S - D600D INSTRUCTI MANUAL SIL Switch/Proximity Detector Repeater Relay, DIN Rail, Models D600S, D600D D600 - SIL Switch/Proximity Detector Repeater Relay G.M. International ISM0- Characteristics General

More information

3.3. Control Relays and Timers

3.3. Control Relays and Timers . Contents Description easy500/700/800..... easy802/806 with SmartWire-DT.................... easyrelay and MFD Expansion Modules..... MFD-Titan Multi-Function s......... easyrelay Communication Modules........

More information

ABL1REM24100 regulated SMPS - single phase V input - 24 V output W

ABL1REM24100 regulated SMPS - single phase V input - 24 V output W Characteristics regulated SMPS - single phase - 100..240 V input - 24 V output - 240 W Complementary Input voltage limits Network frequency limits Inrush current Main Range of product Product or component

More information

Metering module NZM-XMC

Metering module NZM-XMC Metering module NZM-XMC Recording and optimising energy Product Information Metering module NZM-XMC Metering and communication module for energy distribution and motor control centres Recording energy

More information

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m Characteristics I/O distributed module OTB - Modbus non isolated serial link - 0..10 m Complementary Topology Bus length Main Number of devices per segment 0...32 Data format Parity Discrete input voltage

More information