EW170 Series Woltman Bulk Water Meters DN FOR COLD AND WARM POTABLE WATER APPLICATIONS

Size: px
Start display at page:

Download "EW170 Series Woltman Bulk Water Meters DN FOR COLD AND WARM POTABLE WATER APPLICATIONS"

Transcription

1 EW70 Series Woltman Bulk Water Meters DN50 25 FOR COLD AND WARM POTABLE WATER APPLICATIONS CONTENTS PRODUCT DATA Fig.. EW70xA Series Contents... General... 2 Application... 2 Features... 2 Design... 2 Materials... 2 Approvals... 2 Technical Details... 3 Specifications... 3 Flow Data... 3 Sizing... 3 Function... 3 Mechanical Counter (EW70xA)... 3 Electronic Counter (EW70xB)... 3 Flow Sensor... 3 Power Supply... 3 Interfaces... 4 Installation... 4 Communication and Readout... 4 Communication Options EW70xA... 4 Communication Options EW70xB... 4 Optical interface on front panel... 4 Readout Options... 4 Setup... 4 Identification... 4 Meter Identification in the Field... 4 Front Panel and Type Plate Contents... 5 Dimensions... 6 Ordering Details... 7 Ordering Information... 7 Scope of Delivery... 7 Accessories... 7 Diagrams... 8 Accuracy... 8 Flow Diagram... 8 Fig. 2. EW70xB Series Honeywell All rights reserved EN0H-046GE25 R033

2 GENERAL Application Honeywell EW70 Series Woltman water meters are used for flow measurement of cold or warm water in potable water systems. EW70xA (i.e. EW700A and EW70A) water meters have a mechanical roller counter and can be equipped with up to two reed switches for pulse output. EW70xB (i.e. EW700B and EW70B) water meters have an electronic counter and an M-Bus and ZVEI optical output. Features Suitable for horizontal and vertical installation Calibratable sealed measuring insert Low pressure loss Rugged design for longterm accuracy Integrated outputs as standard Design EW70 Series water meters consist of: Rotatable mechanical or electronic counter. Electronic counter with optical interface Optional pulse or M-Bus output Woltman type mechanical flow sensor Housing with flanges to PN6 Materials Counter housing and lid made of white plastic Counter base and flow sensor housing made of cast iron, painted dark grey Approvals Table. Approvals EW70 Series Size Approval Metrological class EW700A DN50 65 EC type approval B H DN80 25 EC type approval B EW700B DN50 65 National approval B H DN80 25 National approval B Fig. 3. EW70xA main components Fig. 4. EW70xB main components Table 2. EW30 Series main components Number Component Counter lid 2 Roller counter (EW70xA) or seven digit LCD display (EW70xB) 3 Decimal place dials 4 Counter housing 5 Inlet 6 Flow sensor housing 7 Outlet 8 Flow indicator 9 Optical interface 0 Push button EN0H-046GE25 R033 2 Honeywell All rights reserved

3 TECHNICAL DETAILS Specifications Medium Medium temperature Ambient temperature Storage temperature Operating pressure Protection class Measuring process Flow Data Potable water EW700: 0 30 C EW70: 0 90 C 0 55 C 0 55 C max. 6bar EW70xA: IP68 EW70xB: IP54 Mechanical or electronic counter unit with Woltman type mechanical volume measurement Display EW70xA: mechanical counter EW70xB: LCD, 7-digit Units EW70xA: m³ EW70xB: m³/h, l/h, m³, l Metrological class Battery lifetime DN50 65: B H DN80 25: B 0 years (EW70xB only) Table 3. Flow rates EW70 Series DN size Starting l/h Minimum horizontal (Q min) m³/h Minimum vertical (Q min) m³/h Transition horizontal (Q t) m³/h Transition vertical (Q t) m³/h Nominal (Q n) m³/h Permissable continuous load m³/h Maximum short term (Q max) m³/h Dynamic range (Qn/Q min) 40: 50: 80: 00: 60: Flow Δp=00mbar m³/h Sizing EW70 Series water meters should be selected in such a way that permanent system flow rates are between transition flow rate (Qt) and nominal flow rate (Qn). The flow rate may not drop below minimum flow rate (Qmin) and should not exceed permissable continuous load for more than 5 minutes per day Maximum short term flow rate (Qmax) must not be exceeded at any time Function Mechanical Counter (EW70xA) The mechanical counter contains a roller counter for values of whole m³ and dials for tenth, hundredth and thousandth parts of m³. It is flanged to the flow sensor housing. Electronic Counter (EW70xB) The electronic counter (or simply counter ) contains circuits for recording the flow and displaying data. It is flanged to the flow sensor housing. The meter can be read from a single line seven-digit display with units and symbols. A push button provides control of various display loops. All failures and faults are recorded automatically and displayed on the LCD screen. For protection all relevant data is saved in a volatile memory. This memory saves measured values, device parameters and types of error at regular intervals Flow Sensor The Woltman technology of the flow sensor combines high measuring accuracy with long term stability and the capability of measuring high volumes at low pressure drop. The Woltman wheel is connected to the counter by a shaft and a magnetic coupling. Power Supply Lithium battery 3.0V DC with 0 year nominal lifetime (EW70xB only). Interfaces EW70 Series with roller counter Retrofittable with up to two pulse outputs. EW70 Series with electronic counter Equipped with ZVEI optical interface and M-Bus interface on board as standard. For more details on interfaces see chapter Communication and Readout below. Honeywell All rights reserved 3 EN0H-046GE25 R033

4 Installation Calming legs of straight pipe with a minimum length of 3 x DN before and after EW70 Series water meters are required Calming legs of straight pipe with a minimum length of 5 x DN are required before or after elbows All sizes may be installed in any position except upside down Avoid installation at highest point of system or system part as air may be trapped in meter During measurement meter must be completely filled with water Communication and Readout Communication Options EW70xA EW70 Series water meters with mechanical roller counter can be retrofitted with up to two pulse outputs. This is done by attaching one or two reed switches to the counter housing. The pulse value depends on the position where the reed switch is attached: Position has a pulse value of 00 litres/pulse Position 2 has a pulse value of,000 litres/pulse Either position can be used. It is also possible to occupy both positions in which case two reed switches are required. Available reed switches are listed in chapter Accessories further below. Installation of the reed switches is explained in the installation and setup instructions supplied with the product. Communication Options EW70xB EW70 Series water meters with electronic counter have an optical interface on the front panel and an M-Bus interface on board. Optical interface on front panel ZVEI interface, M-Bus protocol, for readout and parametrisation. Required for access to meter: Bluetooth optohead (EWA300799) PC with HydroSet software M-Bus interface Configurable telegram, according to EN3757-3, data reading and parametrization via two wires with polarity reversal protection, auto baud detection (300 and 2400 baud), 2 M-Bus connections with 2 primary adresses. Readout Options Manual readout by visiting meter and reading consumption values off display Optical: by visiting meter and reading consumption values out via optical interface (EW70xB only) Pulse: remote readout by attaching meter to a suitable pulse counting device (EW70xA only) RF: remote readout by attaching meter to a mobile or fixed RF network. Additional items required. M-Bus: remote readout by attaching meter to an M-Bus network Table 4. Readout options EW70 Series EW70xA EW70xB Optical Not possible With BT optohead EWA300799, HydroSet software and suitable PC Pulse With reed switch Not possible EWA63006 or EWA M-Bus RF Setup With reed switch and external M-Bus module EW535M0056 With reed switch and external RF module EW900AGZ00 No field setup at meter required. Identification Meter Identification in the Field Included as standard With external RF module EW900AEZ00 Counter EW70xA (mechanical): white round rotatable counter housing permanently fixed to flow sensor housing. Roller counter, flow indicator and dials for decimal places Type plate attached to side of counter housing EW70xB (electronic): white front panel with LCD display and black Honeywell logo above display Type plate included on front panel Flow sensor Flanged housing painted dark grey with DN size embossed on side EN0H-046GE25 R033 4 Honeywell All rights reserved

5 Front Panel and Type Plate Contents EW70 Series water meters with a mechanical counter have additional typeplates which are attached to the side of the counter housing. There are two typeplates which carry specification, approval and product information and a third label with a barcode of the serial number. EW70 Series water meters with an electronic counter have this information printed onto the counter panel Fig. 5. Top view of mechanical counter Fig. 6. Type plate contents of version with mechanical counter Fig. 7. Top view of electronic counter Table 5. EW30 Series front panel and type plate elements Number Element Number Element Unit 3 Approval mark 2 Unused 4 Production year x unit dial 5 OS Number x unit dial 6 Maximum static pressure in bar 5 Indicates reed switch position pulse value 7 Serial number 0.m³ (00l) 6 Indicates reed switch position 2 pulse value 8 DN size m³ (,000l) 7 0. x unit dial 9 Approval number 8 Differential pressure at nominal flow 20 Dynamic range 9 Internal typename 2 Production year (first two digits) and serial number 0 Nominal flow 22 Interface type Metrological / environmental class 23 Replacement date 2 Maximum media temperature 24 Decimal place indicator Honeywell All rights reserved 5 EN0H-046GE25 R033

6 Dimensions Fig. 8. Dimensions Fig. 9. Dimensions DN Size Length L Height H Table 6. Dimensions EW70 Series Height H Diameter B Diameter D Bolt circle K Screwhole D Weight x 4 0.2kg x 4.2kg x 8 3kg x 8 3kg x 8 22kg NOTE: All dimensions in mm unless stated otherwise EN0H-046GE25 R033 6 Honeywell All rights reserved

7 ORDERING DETAILS Ordering Information Table 7. OS-Nos. (OS=Order Specification) OS-Number Item DN size Flow rate Qn Length for cold water for warm water EW70 Series with 50 5 m³/h 200mm EW700AA5000 EW70AA5000 mechanical counter m³/h 200mm EW700AA5600 EW70AA m³/h 200mm EW700AA6500 EW70AA m³/h 250mm EW700AA7300 EW70AA m³/h 250mm EW700AA800 EW70AA800 EW70 Series with 50 5 m³/h 200mm EW700BM5000 EW70BM5000 electronic counter and M-Bus m³/h 200mm EW700BM5600 EW70BM m³/h 200mm EW700BM6500 EW70BM m³/h 250mm EW700BM7300 EW70BM m³/h 250mm EW700BM800 EW70BM800 Scope of Delivery EW70 Series water meter Installation and setup instructions Accessories Reed switch for pulse output Cable length 2m Cable length 0m EWA63006 EWA External RF module For EW700BM and EW70BM For EW700AA and EW70AA External M-Bus module For EW700AA and EW70AA EW900AEZ00 EW900AGZ00 EW535M0056 Bluetooth optohead For EW700BM and EW70BM EWA Honeywell All rights reserved 7 EN0H-046GE25 R033

8 DIAGRAMS Accuracy Error [%] Flow Diagram Q min B Q t B Q n Q max Fig. 0. Accuracy chart EW70 Series DN Flow rate [m3/h] kg/h Flow rate 0.28 l/sec Fig.. Pressure drop diagram EW70 Series 0 mbar 000 Pa Pressure loss Environmental and Combustion Controls Honeywell GmbH Hardhofweg 7482 MOSBACH GERMANY Phone: +49 (626) 80 Fax: +49 (626) EN0H-046GE25 R033 March 203 (Rev. B) 203 Honeywell International Inc. Subject to change without notice Manufactured for and on behalf of the Environmental and Combustion Controls Division of Honeywell Technologies Sàrl, Z.A. La Pièce 6, 80 Rolle, Switzerland or its Authorized Representative.

EW773 Series Ultrasonic Hydronic Meters FOR HEATING AND COOLING APPLICATIONS

EW773 Series Ultrasonic Hydronic Meters FOR HEATING AND COOLING APPLICATIONS Design EW7730K1200 qi: 0.015m 3 /h qp: 1.5m 3 /h qs: 3m 3 /h O: 5...130 C DN: 15 IP 54 PN: 16 Typ: 773 77300000 T.sensor: Pt 500 O: 0...180 C O: 3...177K Environm. class: E1 Mechanical class: M1 Metrological

More information

EW500 Series Energy Calculators FOR HEATING AND CHILLED WATER ENERGY METERING

EW500 Series Energy Calculators FOR HEATING AND CHILLED WATER ENERGY METERING EW500 Series Energy Calculators FOR HEATING AND CHILLED WATER ENERGY METERING Application PRODUCT DATA Honeywell EW500 energy calculators are used for energy consumption metering in hydronic heating and

More information

EW773 Series Ultrasonic Hydronic Meters DN FOR HEATING AND COOLING APPLICATIONS

EW773 Series Ultrasonic Hydronic Meters DN FOR HEATING AND COOLING APPLICATIONS EW773 Series Ultrasonic Hydronic Meters DN15 100 FOR HEATING AND COOLING APPLICATIONS CONTENTS PRODUCT DATA Contents... 1 General... 2 Application... 2 Features... 2 Design... 2 Materials... 2 Approvals...

More information

DATASHEET ULTRASONIC COMPACT ENERGY METER MODEL 773

DATASHEET ULTRASONIC COMPACT ENERGY METER MODEL 773 APPLICATION Static compact energy meter using ultrasonic technology Highly accurate recording of all billing data in local and district heating and cooling systems FEATURES 1st. approval in Europe for

More information

SONOMETER TM 500 Ultrasonic compact energy meter

SONOMETER TM 500 Ultrasonic compact energy meter Data sheet SONOMETER TM 500 Ultrasonic compact energy meter Description/Application MID examination certificate No.: DE-13-MI004-PTB011 The SONOMETER 500 is an ultrasonic static compact energy meter designed

More information

RNN5-STD NETWORK NODE FOR AMR SYTEMS

RNN5-STD NETWORK NODE FOR AMR SYTEMS RNN5-STD NETWORK NODE FOR AMR SYTEMS GENERAL PRODUCT DATA CONTENTS Contents... 1 General... 1 Applications... 1 Features... 1 Technical Details... 1 Specifications... 2 CE Norms and Standards... 2 Installation...

More information

ML7421A,B Electric Linear Valve Actuators

ML7421A,B Electric Linear Valve Actuators ML7421A,B Electric Linear alve Actuators FEATURES Quick and easy installation No separate linkage required No adjustments Force-limiting end switches Manual operator Synchronous motor Corrosion-resistant

More information

SonoSelect 10 and SonoSafe 10 energy meters

SonoSelect 10 and SonoSafe 10 energy meters SonoSelect 10 and SonoSafe 10 energy meters Description The Danfoss SonoSelect 10 and SonoSafe 10 are ultrasonic compact energy meters intended for measuring energy consumption in heating applications

More information

N20010, N NON-SPRING RETURN DAMPER ACTUATOR 20/34 Nm (177/300 lb-in) FOR MODULATING CONTROL SPECIFICATIONS GENERAL FEATURES PRODUCT DATA

N20010, N NON-SPRING RETURN DAMPER ACTUATOR 20/34 Nm (177/300 lb-in) FOR MODULATING CONTROL SPECIFICATIONS GENERAL FEATURES PRODUCT DATA N21, N341 NON-SPRING RETURN DAMPER ACTUATOR 2/34 Nm (177/3 lb-in) FOR MODULATING CONTROL SPECIFICATIONS Supply voltage Nominal voltage PRODUCT DATA 24 Vac 2%, 5/6 Hz; 24 Vdc -1...+2% 24 Vac, 5/6 Hz; 24

More information

SonoSelect and SonoSafe energy meters

SonoSelect and SonoSafe energy meters SonoSelect and SonoSafe energy meters Description The Danfoss SonoSelect and SonoSafe are ultrasonic compact energy meters intended for measuring energy consumption in heating applications for billing

More information

PolluTherm. Integrator for measuring heating and cooling energy. Main characteristics. Available design.

PolluTherm. Integrator for measuring heating and cooling energy. Main characteristics. Available design. PolluTherm Integrator for measuring heating and cooling energy Main characteristics Available design Compatible with almost any flow sensor type due to 9 different input pulse values (1 litre to 10,000

More information

Level sensor Stainless steel version Model RLT-1000, for industrial applications

Level sensor Stainless steel version Model RLT-1000, for industrial applications Level measurement Level sensor Stainless steel version Model RLT-1000, for industrial applications WIKA data sheet LM 50.02 Applications Level measurement of liquids in machine building Control and monitoring

More information

PolluTherm. calculator hous. 2 from hous. 1 until X X X X X* X* M-Bus- M-Bus and 2 2PM pulse inputs X X X X

PolluTherm. calculator hous. 2 from hous. 1 until X X X X X* X* M-Bus- M-Bus and 2 2PM pulse inputs X X X X 1. Use of the option modules There are two different housings with which these same plug-in units can be used namely: Calculator housing 1 (PolluTherm, PolluStat E and PolluFlow 2010) indicated by a lid

More information

2 CLASS AMR READY INVONIC H DATA APPLICATION HEAT METERING. approved ULTRASOUND HEAT AND COOLING METERS DN15, DN20, DN25, DN40, DN50

2 CLASS AMR READY INVONIC H DATA APPLICATION HEAT METERING. approved ULTRASOUND HEAT AND COOLING METERS DN15, DN20, DN25, DN40, DN50 SMART THINKING HEAT INVONIC H ULTRASOUND HEAT AND COOLING METERS DN15, DN20, DN25, DN40, DN50 approved 2 CLASS AMR READY INVONIC H is a modern and precise heat and cooling meter utilising an ultrasound

More information

N0524/N1024, N POS/N POS

N0524/N1024, N POS/N POS N0/N0, N00-POS/N00-POS NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR FLOATING / -POSITION CONTROL PRODUCT DATA SPECIFICATIONS Supply voltage N0/N0 Vac/dc -%/+0%, 0/60 Hz N00-POS/N00-POS 0 Vac -%/+0%,

More information

N05010/N10010 NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR MODULATING AND FLOATING / 2-POSITION CONTROL SPECIFICATIONS

N05010/N10010 NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR MODULATING AND FLOATING / 2-POSITION CONTROL SPECIFICATIONS N/N NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR MODULATING AND FLOATING / -POSITION CONTROL SPECIFICATIONS Supply voltage Nominal voltage PRODUCT DATA Vac/dc -%/+%, /6 Hz Vac/dc, /6 Hz All values

More information

LMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0.

LMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0. LMP 08 Separable Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.25 % FSO / 0. % FSO Nominal pressure from 0... mh 2 O up to 0... 250 mh 2 O Output signals 2-wire:

More information

Thermal Mass Flowmeter Sensyflow FMT200-D

Thermal Mass Flowmeter Sensyflow FMT200-D Data Sheet Thermal Mass Flowmeter Sensyflow FMT200-D Direct measurement of mass flow or standard volume flow of compressed air, nitrogen and biogas independent of media pressure and temperature Wide measuring

More information

Diaphragm gas meters with Absolute ENCODER

Diaphragm gas meters with Absolute ENCODER Gas Metering Diaphragm gas meters with Absolute ENCODER Absolute ENCODER index AE5 for diaphragm gas meters BK-G..A Diaphragm gas meters BK-G1.6 to BK-G1 Applications The electronically readable mechanical

More information

RoHS. High shaft load capacity. Shock / vibration resistant

RoHS. High shaft load capacity. Shock / vibration resistant Due to their sturdy bearing construction in Safety-Lock Design, the Sendix 5000 and 5020 offer high resistance against vibration and installation errors. The rugged housing, high protection level of up

More information

SITRANS F flowmeters SITRANS F US. SITRANS FUE950 energy calculator. 4/240 Siemens FI

SITRANS F flowmeters SITRANS F US. SITRANS FUE950 energy calculator. 4/240 Siemens FI s INFOCAL 5 s INFOCAL 5 s INFOCAL 5 Overview Application The SITRANS FUE950 is able to handle 3 kinds of applications, means energy calculation in: District heating applications Chilled water applications

More information

Installation Guide Solid State Meter

Installation Guide Solid State Meter Installation Guide Solid State Meter Document version v0.2 February 2018 1 Where Intelligence Meets Infrastructure TM Contents About this Installation Guide... 3 Transport and storage... 3 Installation

More information

Absolute Encoders Multiturn

Absolute Encoders Multiturn The multiturn encoders 5868 and 5888 with interface and optical sensor technology are ideal for use in all applications with a interface. The encoder supports the isochronous (IRT) mode and is therefore

More information

Static Heat Meter ULTRAHEAT XS 2WR6... UH f. Configuration and composition

Static Heat Meter ULTRAHEAT XS 2WR6... UH f. Configuration and composition UH 504-101f Static Heat Meter ULTRAHEAT XS 2WR6... Configuration and composition Meter for measurement of flow and heat energy in a heat exchanger circuit with water using an ultrasonic principle. Important

More information

Immersion Temperature Sensors

Immersion Temperature Sensors 1 782 1782P01 Symaro Immersion Temperature Sensors QAE2164 QAE2174 Active sensors for acquiring the water temperature in pipes and tanks Operating voltage AC 24 V or DC 13535 V Signal output DC 010 V or

More information

Flow Measurement SITRANS F US Inline

Flow Measurement SITRANS F US Inline s INFOCAL 5 s INFOCAL 5 s INFOCAL 5 Overview Application The SITRANS FUE950 is able to handle kinds of applications, means energy calculation in: District heating applications Chilled water applications

More information

T7270B2009 WIRELESS WALL MODULE

T7270B2009 WIRELESS WALL MODULE T7270B2009 WIRELESS WALL MODULE HONEYWELL EXCEL 5000 OPEN SYSTEM INSTALLATION AND OPERATING INSTRUCTIONS STANDARDS AND NORMS The ZAPP System complies with CE and EN 300 220-1 and EN 301 489-1. IMPORTANT!

More information

AB Axis Industries. Use

AB Axis Industries. Use AB Axis Industries PULSE ADAPTER ENCO PULSE The ENCO PULSE pulse adapter acquires and handles the pulses from consumption meters with pulse output and transmits the data to a network of AMR system. Use

More information

5/2 and 5/3 Directional-control valves, Series TC 15, G 1/4

5/2 and 5/3 Directional-control valves, Series TC 15, G 1/4 5/2 and 5/3 Directional-control valves, Series TC 15, G 1/4 Products 5/2 Directional-control valve, single valve, electrical connection M8 (4 poles) 5/3 Directional-control valve, single valve, electrical

More information

Float switch For industrial applications Model RLS-1000

Float switch For industrial applications Model RLS-1000 Level measurement Float switch For industrial applications Model RLS-000 WIKA data sheet LM 50.0 Applications Level measurement of liquids in machine building Control and monitoring tasks for hydraulic

More information

Solenvis SL80 Pulse to M-Bus Converters

Solenvis SL80 Pulse to M-Bus Converters Solenvis SL80 Pulse to M-Bus Converters The SOLENVIS SL80 series of devices connects meters with contact output to the M-Bus system. This is a simple and flexible solution for reading already installed

More information

Metering systems 0670EN February 2014 Volumetric thermal energy meters for use in a boiler room GE552-1 series

Metering systems 0670EN February 2014 Volumetric thermal energy meters for use in a boiler room GE552-1 series OA 0064/1 Threaded version Flanged version GE552-1 The GE552-1 volumetric meters are used in the boiler room, to measure the heating and conditioning energy. They are strongly recommended for energy balancing

More information

SITRANS F US Inline. SITRANS FUE950 energy calculator 4/269

SITRANS F US Inline. SITRANS FUE950 energy calculator 4/269 s INFOCAL 5 s INFOCAL 5 s INFOCAL 5 Overview Application The SITRANS FUE950 is able to handle 3 kinds of applications, means energy calculation in: District heating applications Chilled water applications

More information

Data sheet: Wilo-Stratos 40/1-8

Data sheet: Wilo-Stratos 40/1-8 Data sheet: Wilo-Stratos 4/1-8 Pump curves 1 2 v 3 4 DN4 m/s,5 1, 1,5 2, 2,5 DN5 H/m Wilo-Stratos 4/1-8 p/kpa Wilo-Stratos 5/1-8 48 1 /min - 1 V 1~23 V - DN 4 / DN 5 8 8 P 1/W n= const 6 383 1 /min - 8

More information

Data sheet: Wilo-Stratos 50/1-9

Data sheet: Wilo-Stratos 50/1-9 Data sheet: Wilo-Stratos 5/1-9 Pump curves H/m 2 5 1 15 2 1 v 1 2 3 1 41 1 /min-1 V 8 3714 1 /min-9 V 3329 1 /min-8 V 6 4 57 1 /min-6 V 2 4 6 P 1/W n= const 4 8 V 2 H/m 2943 1 /min-7 V 2171 1 /min-5 V

More information

AEW36.2. Pulse Adapter. Building Technologies. Siemeca AMR

AEW36.2. Pulse Adapter. Building Technologies. Siemeca AMR 2 873 Siemeca AMR Pulse Adapter AEW36.2 The AEW36.2 pulse adapter acquires and handles the pulses from 1 or 2 consumption meters with pulse output and transmits the data to a Siemeca AMR network. For setting

More information

Data sheet: Wilo-Stratos 50/1-10

Data sheet: Wilo-Stratos 50/1-10 Data sheet: Wilo-Stratos 5/1-1 Pump curves v,4,8 1,2 1,6 2, 2,4DN 4 m/s,4,8 1,2 DN 5 H/m p/kpa Wilo-Stratos 4/1-1 445 1 /min - 1 V Wilo-Stratos 5/1-1 1 1~23 V - DN 4, DN 5 8 P 1/W n= const 6 314 1 /min

More information

LMP 308i. Separable Stainless Steel Probe Precision. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

LMP 308i. Separable Stainless Steel Probe Precision. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO Separable Stainless Steel Probe Precision Stainless Steel Sensor accuracy according to IEC 60770: 0. % FSO Nominal pressure from 0... mho up to 0... 00 mho Output signals wire:... 0 ma wire: 0... 0 V others

More information

Standard PROFINET IO. RoHS. High shaft load capacity. High protection level. Flexible

Standard PROFINET IO. RoHS. High shaft load capacity. High protection level. Flexible The encoders Sendix 5868 and 5888 with PROFINET interface and optical sensor technology are ideal for use in all applications with PROFINET technology. The encoder supports the isochronous (IRT) mode and

More information

C-Flow Coriolis Mass Flow Meter

C-Flow Coriolis Mass Flow Meter Coriolis Mass Flow Meter Application and Features For fluids (e.g. PU components, paints) and gases of high density Suitable for aggressive and contaminated media Measurement of mass flow, density, temperature

More information

Absolute Encoders Multiturn

Absolute Encoders Multiturn The Sendix multiturn encoders 5868 and 5888 with CANopen or CANlift interface and optical sensor technology are the right encoders for all CANopen or CANlift applications. With a maximum resolution of

More information

Operating Instructions for Turbine Wheel Flow Meter Model: TUR

Operating Instructions for Turbine Wheel Flow Meter Model: TUR Operating Instructions for Turbine Wheel Flow Meter Model: TUR TUR 1. Instructions Please read this Service Manual carefully before unpacking and commissioning the unit. The unit may only be used, maintained

More information

Temperature sensors and accessories for heat and cooling measurement points

Temperature sensors and accessories for heat and cooling measurement points Temperature sensors and accessories for heat and cooling measurement points Applications Temperature sensors are metrological components for heat or cold measuring points. They are used in pairs and measure

More information

AEW Pulse Adapter. Building Technologies

AEW Pulse Adapter. Building Technologies 5 383 Pulse Adapter AEW310.2 The AEW310.2 pulse adapter acquires and handles the pulses from 1 or 2 consumption meters with pulse output and transmits the data to an M-Bus-network. For setting the parameters,

More information

C7110C1001A / C7110D1009A WALL MODULES

C7110C1001A / C7110D1009A WALL MODULES HONEYWELL EXCEL 5000 OPEN SYSTEM GENERAL The C7110C1001A and C7110D1009A are combined CO2 / temperature wall modules designed for applications in indoor ventilation and air conditioning systems. In conjunction

More information

Flow Measurement SITRANS F US Inline

Flow Measurement SITRANS F US Inline s INFOCAL 5 s INFOCAL 5 s INFOCAL 5 Siemens AG 2017 Overview Application The SITRANS FUE950 is able to handle kinds of applications, means energy calculation in: District heating applications Chilled water

More information

Operating Instructions for Low Volume Rotating Vane Flow Meter. Model: DPL-1P... DPL-1V... DPL-1E...

Operating Instructions for Low Volume Rotating Vane Flow Meter. Model: DPL-1P... DPL-1V... DPL-1E... Operating Instructions for Low Volume Rotating Vane Flow Meter Model: DPL-1P... DPL-1V... DPL-1E... 1. Contents 1. Contents... 2 2. Note... 3 3. Instrument Inspection... 3 4. Regulation Use... 3 5. Operating

More information

T7560A,B,C Digital Wall Module

T7560A,B,C Digital Wall Module T7560A,B,C Digital Wall Module HONEYWELL EXCEL 5000 OPEN SYSTEM FEATURES SPECIFICATION DATA Fully compatible with all current Excel 10 and Excel 20 to 800 controllers. Low power consumption. Integral 20kΩ

More information

Flow Measurement SITRANS F US Inline

Flow Measurement SITRANS F US Inline s INFOCAL 5 s INFOCAL 5 s INFOCAL 5 Siemens AG 2016 Overview Application The SITRANS FUE950 is able to handle kinds of applications, means energy calculation in: District heating applications Chilled water

More information

JUMO PINOS L01. Calorimetric flow sensor. Brief description. Special features. Customer benefits. Data Sheet

JUMO PINOS L01. Calorimetric flow sensor. Brief description. Special features. Customer benefits. Data Sheet sales@jumo.co.uk info.us@jumo.net Page 1/9 JUMO PINOS L01 Calorimetric flow sensor Brief description The JUMO PINOS L01 flow sensor serves the measuring and monitoring of flow velocities of water and aqueous

More information

accurate measurement of compressed air consumption and leakage detection Calibration certificates and continous calibration, OEKD calibration service

accurate measurement of compressed air consumption and leakage detection Calibration certificates and continous calibration, OEKD calibration service Series Flowmeter for compressed air and gases in Industrial Applications The flowmeter of the series, based on the measurement principle of thermal mass flow, is ideally suited for the measurement of flow

More information

Rotary Position Technology Absolute Encoders, Singleturn

Rotary Position Technology Absolute Encoders, Singleturn -20 to 85 C High rotational speed Temperature Shock/vibration resistant Short-circuit proof Reverse polarity protection Optical sensor Magnetic field proof Rugged Highest shock resistance on the market:

More information

Operating Instructions for Low Volume Rotating Vane Flow Meter. Model: DPL-1P... DPL-1V... DPL-1E...

Operating Instructions for Low Volume Rotating Vane Flow Meter. Model: DPL-1P... DPL-1V... DPL-1E... Operating Instructions for Low Volume Rotating Vane Flow Meter Model: DPL-1P... DPL-1V... DPL-1E... 1. Contents 1. Contents... 2 2. Note... 3 3. Instrument Inspection... 3 4. Regulation Use... 3 5. Operating

More information

Entering a Whole New Dimension The ULTRAHEAT XS Heat Meter

Entering a Whole New Dimension The ULTRAHEAT XS Heat Meter Entering a Whole New Dimension The ULTRAHEAT XS Heat Meter Volume measuring unit [ Highest measurement accuracy ULTRAHEAT XS measures flow rate by the ultrasonic dragging principle. Two transducers alternately

More information

Differential pressure sensor For ventilation and air-conditioning Model A2G-50

Differential pressure sensor For ventilation and air-conditioning Model A2G-50 Electronic pressure measurement Differential pressure sensor For ventilation and air-conditioning Model A2G-50 WIKA data sheet PE 88.02 for further approvals see page 5 Applications For measuring differential

More information

QVE3000.0xx QVE3100.0xx. Flow sensor. for liquids in DN10 25 pipes

QVE3000.0xx QVE3100.0xx. Flow sensor. for liquids in DN10 25 pipes s 1 598 Flow sensor for liquids in DN10 25 pipes QVE3000.0xx QVE3100.0xx Vortex flow sensor made from robust red brass Output signal: DC 0 10 V or 4 20 ma Flow range: 1.8 150 l/min Used for temperature

More information

LMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0.

LMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0. LMP 07 Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % / 0. % FSO Nominal pressure from 0... mh O up to 0... 50 mh O Output signals -wire: 4... 0 ma -wire: 0...

More information

Data sheet: Wilo-Stratos 30/1-8

Data sheet: Wilo-Stratos 30/1-8 Data sheet: Wilo-Stratos 3/1-8 Pump curves 7 337 1 /min - 9 V 6 34 1 /min - 8 V 5 271 4 1 /min - 7 V 239 1 /min - 6 V 3 26 1 /min - 5 V 2 173 1 /min - 4 V 14 1 1 /min - 3 V 2 4 6 8,5 1, 1,5 2, 2,5 Q/l/s

More information

LMP 308i. Separable Stainless Steel Probe Precision. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO.

LMP 308i. Separable Stainless Steel Probe Precision. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO. LMP 08i Separable Stainless Steel Probe Precision Stainless Steel Sensor accuracy according to IEC 60770: 0. % FSO Nominal pressure from 0... mh O up to 0... 00 mh O Output signals wire:... 0 ma wire:

More information

T7460A,B,C,D,E,F WALL MODULES

T7460A,B,C,D,E,F WALL MODULES T7460A,B,C,D,E,F WALL MODULES HONEYWELL EXCEL 5000 OPEN SYSTEM SPECIFICATION DATA FEATURES Mountable on 2.36 in. (60 mm) wall outlet box or directly on a wall. Models with setpoint adjustment. Models with

More information

SM9000. Made in Germany

SM9000. Made in Germany Made in Germany Product characteristics Magnetic-inductive flow meter Connector Process connection: G2 flat seal connection to pipe by means of an adapter Function programmable Totaliser function Empty

More information

Rotary Position Technology Incremental Encoders

Rotary Position Technology Incremental Encoders -40 to 85 C IP Safety-Lock High rotational speed Temperature High IP High shaft load capacity Shock/vibration resistant Magnetic field proof Short-circuit proof Reverse polarity protection Optical sensor

More information

Electro-Mechanical Counters

Electro-Mechanical Counters Electro-Mechanical Counters measuring monitoring analysing Input: pulse counter Display: 5, 6, 7 and 8 digits plastic Panel mounted : 4.5 V DC ; V DC ; 4 V DC ; 5 V AC ; 0 V AC KOBOLD offices exist in

More information

SonoMeter 30 Ultrasonic energy meter for heating and cooling applications

SonoMeter 30 Ultrasonic energy meter for heating and cooling applications Installation & User Guide SonoMeter 30 Ultrasonic energy meter for heating and cooling applications www.danfoss.com 2 Danfoss Energy Meters 2016.06 VUIGJ102 1. Installation 1.1. Preparation Only qualified

More information

EE771 Series. Flowmeter for compressed air and gases in Industrial Applications. EE771 Compact. EE771 remote probe

EE771 Series. Flowmeter for compressed air and gases in Industrial Applications. EE771 Compact. EE771 remote probe Series Flowmeter for compressed air and gases in Industrial Applications The flowmeter of the series, based on the measurement principle of thermal mass flow, is ideally suited for the measurement of flow

More information

SERIE 59. Rear clamp. Frontal clamp HIGH RESOLUTION HOLLOW SHAFT INCREMENTAL ENCODER FOR INDUSTRIAL APPLICATIONS

SERIE 59. Rear clamp. Frontal clamp HIGH RESOLUTION HOLLOW SHAFT INCREMENTAL ENCODER FOR INDUSTRIAL APPLICATIONS HIGH RESOLUTION HOLLOW SHAFT INCREMENTAL ENCODER FOR INDUSTRIAL APPLICATIONS Resolution up to 50.000 pulses per turn External diameter 58 mm Hollow shaft from Ø 10 to 14 mm Protection class IP67 according

More information

SonoMeter 30 Ultrasonic energy meter for heating and cooling applications

SonoMeter 30 Ultrasonic energy meter for heating and cooling applications Installation guide SonoMeter 30 Ultrasonic energy meter for heating and cooling applications www.danfoss.com Danfoss A/S DK-6430 Nordborg Denmark CVR nr.: 20 16 57 15 Telephone: +45 7488 2222 Fax: +45

More information

PN DN FIG. 660D-BATT+670D-BATT 661D-BATT+670D-BATT SISTEMI DI MISURA / SYSTEM MEASURE / SYSTEMES DE KAT KAT-06...

PN DN FIG. 660D-BATT+670D-BATT 661D-BATT+670D-BATT SISTEMI DI MISURA / SYSTEM MEASURE / SYSTEMES DE KAT KAT-06... 1 2 BATTERY-OPERATED WATER METER MAG 8000 MAG 8000 is a comprehensive meter which intelligent information and high performance measurement as well as the easy to install concept take cost of ownership

More information

SM9000. Magnetic-inductive flow meter. Made in Germany

SM9000. Magnetic-inductive flow meter. Made in Germany Made in Germany Application Application totaliser function; empty pipe detection; for industrial applications Installation connection to pipe by means of an adapter Media conductive liquids; water; hydrous

More information

M-Bus Pulse Collector Twin-Pulse Instruction Manual

M-Bus Pulse Collector Twin-Pulse Instruction Manual M-Bus Pulse Collector Twin-Pulse Instruction Manual Rev. 1 10/13 Maddalena S.p.A. Via G.B. Maddalena 2/4 33040 Povoletto (UD) Italy Tel.: +39 0432/634811 Fax Export Dept.: +39 0432/679820 E-mail: info@maddalena.it

More information

standard, short, preferential, top

standard, short, preferential, top ipf electronic gmbh Kalver Straße 27 standard design short design preferential series top series standard, short, preferential, top norm sensing ranges, increased sensing ranges 1100 1 2 1100 norm sensing

More information

bidirectionally as well as the rotation sense of shafts. With absolute encoders instead, each incremental

bidirectionally as well as the rotation sense of shafts. With absolute encoders instead, each incremental and draw-wire sensors Spot-on and trailblazing technology measure rotation speed, sense, position, angle and length. For this purpose, they convert mechanical motion in electrical signals. There are incremental

More information

Standard CANopen/CANopenLift. RoHS. High protection level. High shaft load capacity. Flexible

Standard CANopen/CANopenLift. RoHS. High protection level. High shaft load capacity. Flexible CANopen/CANopenift The Sendix multiturn encoders 868 and 888 with CANopen or CANopenift interface and optical sensor technology are the right encoders for all CANopen or CANopenift applications. With a

More information

HOBO State Data Logger (UX90-001x) Manual

HOBO State Data Logger (UX90-001x) Manual HOBO State Data Logger (UX90-001x) Manual The HOBO State/Pulse/Event/Runtime data logger records state changes, electronic pulses and mechanical or electrical contact closures from external sensing devices.

More information

Electromotoric actuators

Electromotoric actuators 4 861 ACVATIX Electromotoric actuators for Combi-valve types VPI45.., DN15 32 SSD31.. SSD81.. SSD61.. SSD31.. operating voltage AC 230 V 3-position control signal SSD81.. operating voltage AC 24 V 3-position

More information

Type Approval Certificate

Type Approval Certificate Type Approval Certificate Type Approval Identification: SA 1491 AA3 Issuing Authority: NRCS, Legal Metrology, Type Approval Identification of Instrument: Utility Systems Model WMD in-line electronic pre-payment

More information

Electrical Energy Meter with integrated Serial Modbus interface

Electrical Energy Meter with integrated Serial Modbus interface Electrical Energy Meter with integrated Serial Modbus interface EEM230-D-MO Electrical energy meter with an integrated serial RS485 Modbus interface allow direct reading of all relevant data, such as energy

More information

RoHS. Shock / vibration resistant. Short circuit proof. Flexible. . XXXX e. . XXXX e

RoHS. Shock / vibration resistant. Short circuit proof. Flexible. . XXXX e. . XXXX e The Sendix multiturn encoders 5862 and 5882, with SSI or RS485 interface and combined optical and magnetic sensor technology, offer a maximum resolution of 25 bits. These encoders are programmable via

More information

Induction Flow Meter. AcquaMAG. Installation and Operating Manual

Induction Flow Meter. AcquaMAG. Installation and Operating Manual Induction Flow Meter AcquaMAG Installation and Operating Manual CONTENT 1 INTRODUCTION... 3 2 MOUNTING INSTRUCTIONS... 3 2.1 LOCATION... 3 2.2 ELECTRIC CONNECTION... 6 2.3 ELECTRONICS HOUSING SEALING...

More information

Operating Instruction for Turbine-wheel Flow Meter. Model: DRS

Operating Instruction for Turbine-wheel Flow Meter. Model: DRS Operating Instruction for Turbine-wheel Flow Meter Model: DRS . Contents. Contents... 2 2. Note... 3 3. Instrument Inspection... 3 4. Regulation Use... 3 5. Operating Principle... 4 6. Mechanical Connection...

More information

Old documentation - Only for your information! Product is not available anymore!

Old documentation - Only for your information! Product is not available anymore! Double solenoid valve Control and safety combination valve Servo pressure controller - / 7. Printed in Germany Rösler Druck Edition 0.08 Nr. 09 8 Technical description The DUNGS multiple actuator DMV-SE...

More information

AEW36.2. Pulse Adapter. Siemeca AMR

AEW36.2. Pulse Adapter.  Siemeca AMR 2 873 Siemeca AMR Pulse Adapter AEW36.2 The AEW36.2 pulse adapter acquires and handles the pulses from 1 or 2 consumption meters with pulse output and transmits the data to a Siemeca AMR network. For setting

More information

Encoder WDGA 36A CANopen

Encoder WDGA 36A CANopen Encoder WDGA 36A CANopen www.wachendorff-automation.com/wdga36acan Wachendorff Automation... systems and encoders Complete systems Industrial rugged encoders to suit your application Standard range and

More information

T7560A1036 Digital Wall Module

T7560A1036 Digital Wall Module T7560A1036 Digital Wall Module HONEYWELL EXCEL 5000 OPEN SYSTEM BEFORE INSTALLATION All wiring must comply with local electrical codes and ordinances or as specified on installation wiring diagrams. T7560A1036

More information

Absolute Encoders Multiturn

Absolute Encoders Multiturn The multiturn encoders 6 and 8, with interface and combined optical and magnetic sensor technology, offer a maximum resolution of 5 bits. These encoders are programmable via the Ezturn software. The hollow

More information

LS series. Electrical Position Indicators for Quarter Turn Actuators

LS series. Electrical Position Indicators for Quarter Turn Actuators 0 Electrical Position ndicators for Quarter Turn Actuators Construction The GEMÜ electrical position indicators are used to indicate and monitor the position of quarter turn valves. Depending on the version,

More information

Encoder WDGA 58B CANopen

Encoder WDGA 58B CANopen Encoder WDGA 58B CANopen www.wachendorff-automation.com/wdga58bcan Wachendorff Automation... systems and encoders Complete systems Industrial rugged encoders to suit your application Standard range and

More information

EC centrifugal module - RadiPac

EC centrifugal module - RadiPac KG9-AR- ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-7467 Mulfingen Phone +49 8 8- Fax +49 8 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart

More information

Screw-Type Flow Meter SVC

Screw-Type Flow Meter SVC Screw-Type Flow Meter SVC Description Screw-type flow meters belong to the group of positive displacement flow meters. Two measuring spindles (pos. 2) with a screw-shaped profile engage with each other.

More information

ULTRASONIC WATER METER HYDROSONIS

ULTRASONIC WATER METER HYDROSONIS ULTRASONIC WATER METER HYDROSONIS TECHNICAL DESCRIPTION, INSTALLATION AND USER INSTRUCTIONS PESF4V01 Content Page SAFETY ORMATION... 33 3 1. APPLICATION FIELD... 3 2. TECHNICAL DATA.... 5 3. OPERATION

More information

multipulse, multilog Installation and operating manual All that counts. EnergyMetering

multipulse, multilog Installation and operating manual All that counts. EnergyMetering EnergyMetering multipulse, multilog Installation and operating manual Electronic pulse counter module with 3 inputs for connection of meters with pulse outputs All that counts. General information With

More information

M3P..G/A, M3P..F/A Modulating control valves (PN16) for chilled and hot water systems

M3P..G/A, M3P..F/A Modulating control valves (PN16) for chilled and hot water systems MP..G/A, MP..F/A Modulating control valves (PN) for chilled and hot water systems Three-way or straight-through valves with magnetic actuators for modulating control of chilled and hot water systems. Short

More information

FAUN PROFESSIONAL, NEW GENERATION INDICATING CALCULATOR FOR SEPARABLE HEAT METERS

FAUN PROFESSIONAL, NEW GENERATION INDICATING CALCULATOR FOR SEPARABLE HEAT METERS FROM metering to data management HEAT MEASUREMENT FAUN PROFESSIONAL, NEW GENERATION INDICATING CALCULATOR FOR SEPARABLE HEAT METERS HEAT MEASUREMENT from metering to data management Vision Apator Group

More information

multipulse, multilog Installation and operating manual All that counts. EnergyMetering

multipulse, multilog Installation and operating manual All that counts. EnergyMetering EnergyMetering multipulse, multilog Installation and operating manual Electronic pulse counter module with 3 inputs for connection of meters with pulse outputs All that counts. General information With

More information

Insertion Flowmeter for compressed air and gases DN50 - DN700 (2-28 )

Insertion Flowmeter for compressed air and gases DN50 - DN700 (2-28 ) The flow meter is based on the thermal mass flow measurement and is ideal for measuring the flow of compressed air and gases in pipes from DN50 (2 ) to DN700 (28 ). With the, the consumption of compressed

More information

Rotary Position Technology Incremental Encoders

Rotary Position Technology Incremental Encoders -40 to 85 C IP Bearing-Lock High rotational speed Temperature High IP High shaft load capacity Shock/vibration resistant Magnetic field proof Short-circuit protected Reverse polarity protection Optical

More information

Encoder WDGA 58A PROFINET-IO (cov)

Encoder WDGA 58A PROFINET-IO (cov) Encoder WDGA 58A PROFINET-IO (cov) www.wachendorff-automation.com/wdga58apnb Wachendorff Automation... systems and encoders Complete systems Industrial rugged encoders to suit your application Standard

More information

EC centrifugal module - RadiPac

EC centrifugal module - RadiPac KG9-AS8- ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-7 Mulfingen Phone +9 798 8- Fax +9 798 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart

More information

ENCODER. Profibus Multiturn. Series , Key-Features:

ENCODER. Profibus Multiturn. Series , Key-Features: ENCODER Profibus Multiturn Series 8.5868, 8.5888 Key-Features: Content: Order Code Technical Data Profibus Interface Connection Technical Drawing......3...4...4...5 - Solid shaft: maximum diameter 0 mm

More information

N20010-SER. NON-SPRING RETURN DAMPER ACTUATOR 20 Nm (177 lb-in) FOR ADJUSTABLE MODULATING CONTROL SPECIFICATIONS GENERAL FEATURES PRODUCT DATA

N20010-SER. NON-SPRING RETURN DAMPER ACTUATOR 20 Nm (177 lb-in) FOR ADJUSTABLE MODULATING CONTROL SPECIFICATIONS GENERAL FEATURES PRODUCT DATA N20010-SER NON-SPRING RETURN DAMPER ACTUATOR 20 Nm (177 lb-in) FOR ADJUSTABLE MODULATING CONTROL GENERAL These direct-coupled damper actuators provide adjustable modulating control for: air dampers, VAV

More information