Electro-Mechanical Counters

Size: px
Start display at page:

Download "Electro-Mechanical Counters"

Transcription

1 Electro-Mechanical Counters measuring monitoring analysing Input: pulse counter Display: 5, 6, 7 and 8 digits plastic Panel mounted : 4.5 V DC ; V DC ; 4 V DC ; 5 V AC ; 0 V AC KOBOLD offices exist in the following countries: ARGENTINA, AUSTRIA, BELGIUM, BRAZIL, CANADA, CHINA, FRANCE, GERMANY, GREAT BRITAIN, ITALY, MEXICO, NETHERLANDS, PERU, POLAND, SWITZERLAND, USA, VENEZUELA KOBOLD Messring GmbH Nordring -4 D-6579 Hofheim/Ts. (069) 99-0 Fax (069) 98 info.de@kobold.com Internet: : ZMZ- ZMZ- ZMZ-5 ZMZ-9 7

2 Micro Count Totalizer The KOBOLD 7-digit micro count totalizer consists of an electromagnetic drive and a mechanical digit roller system. The electrical pulses applied cause the digit rollers to increment. This counter features compact construction, high impact resistance and very low power consumption. Calorimeters Water meters Current meters Vending machines and games Copiers Coin-operated machines Washing systems Alarm systems Medical systems Max. counting frequency: 0 s - except 5 s - (4 V DC version) Min. pulse duration: 50 ms except 0 ms (4 V DC version) Min. pulse interval: 50 ms except 0 ms (4 V DC version) Maximum display: x 4 mm optical None Ambient temperature: -0 to +60 C > 50 x 0 6 pulses x 5 mm, polycarbonate Panel cut-out: 0 x mm Electrical connection: 50 mm stranded wire : 4.5 / V DC -0% +0% 4 V DC ; 5 / 0 V AC ±0% Max. power consumption: Approx. 50 mw at 4.5 / V DC Approx. 50 mw at 4 V DC Approx. 0.8 VA for AC versions Approx. 8 g IP 65 at front x9.9. R max max Ordering details (example: ZMZ-S70 0) ZMZ-S70 Micro count totalizer 0=0 V AC Housing x 5 mm =4 V DC Panel mounted 7-digit display 5= V DC Without manual reset 9=4.5 V DC 8

3 Mini Pulse Counter The KOBOLD 5-digit mini pulse counter consists of an electromagnetic drive and a mechanical digit roller system. The electrical pulses applied cause the digit rollers to increment. This counter features low power consumption and a long service life and is thus well suited for use in battery-powered devices and electronic circuits. Battery driven devices Vending machines Fee/toll collection Max. counting frequency: 0 s - Min. pulse duration: 50 ms Min. pulse interval: 50 ms Maximum display: x 4 mm Manual reset Ambient temperature: -0 to +50 C Counting mechanismaxis: Non-rusting > 50 x 0 6 Impulse 4 x mm Black plastic Panel cut-out:.5 x 0.5 mm Electrical connection: 50 mm stranded wire : / 4 V DC ; 5 / 0 V AC ±0% Max. power consumption: Approx. 0.5 W for DC versions Approx VA at 5 V AC Approx..5 VA at 0 V AC Approximately 48 g IP 65 at front x 6 Ordering details (example: ZMZ-S5 0) ZMZ-S5 Mini Pulse Counter 0=0 V AC Housing 4 x mm =4 V DC Panel mounted 5-digit display 5= V DC With manual reset 9

4 Robust panel-mounted counter with tension-bracket mounting system The robust KOBOLD panel-mounted counter with tensionbracket mounting system is comprised of an electromagnetic drive and a mechanical digit roller system. The electrical pulses applied cause the digit rollers to increment. This counter is available in two model series: 6-digit count totalizer with manual reset 8-digit count totalizer without manual reset Piece counting in production Event counting Timing x Ordering details (example: ZMZ-R6 0) 5x Max. counting frequency: Min. pulse duration: Min. pulse interval: Pulse ratio: 5 s - (DC version) 8 s - (AC version) 4 ms (DC version). ms (AC version) 6 ms (DC version). ms (AC version) : (DC version) : (AC version) Display: 6-digit with manual reset or 8-digit without manual reset x 4 mm (ZMZ-R8) x 4.5 mm (ZMZ-R6) Ambient temperature: -0 to +55 C (AC version) -0 to +60 C (DC version) Permissible acceleration: (universal mounting) g to 0 Hz 6 g to 5 Hz 0 g 0-00 Hz Counting mechanismaxis: Non-rusting Approximately 00 x 0 6 pulses x 8 mm, black plastic Panel cut-out: 50 x 5 mm Electrical connection: Silver-plated pin connectors Ø.5 mm with pin plug : 4 V DC ; 0 V AC ±0% Test voltage: 000 V DC r.m.s., as per VDE 045 Max. power consumption: Approx. W (DC version) Approx..9 VA (AC version) Approx. 8 g (ZMZ-R80) Approx. 8 g (ZMZ-R6) IP 55 at front ZMZ-R6 ZMZ-R80 Sturdy panel-mounted counter Housing 4 x mm 6-digit display with manual reset Sturdy panel-mounted counter Housing 4 x mm 8-digit display without manual reset 0=0 V AC =4 V DC 40

5 Rail-Mounted Micro Count Totalizer The KOBOLD 7-digit micro count totalizer is comprised of an electromagnetic drive and a mechanical digit roller system. The electrical pulses applied cause the digit rollers to increment. This counter features high impact resistance and very low power consumption. Integration in switching and distribution cabinets Max. counting frequency: 0 s - except 5 s - (4 V DC version) Min. pulse duration: 50 ms except 0 ms (4 V DC version) Min. pulse interval: 50 ms except 0 ms (4 V DC version) Maximum display: x 4 mm optical None Ambient temperature: -0 to +60 C > 50 x 0 6 pulses x 5 mm Black polycarbonate Mounting: Rail mount as per DIN and surface-mounted Electrical connection: Terminals : V DC -0 % +0% 4 V DC ; 5/0 V AC ±0% Max. power consumption: Approx. 50 mw at V DC Approx. 50 mw at 4 V DC Approx. 0.8 VA for AC versions Approximately 55 g IP 50 at front Ø Ordering details (example: ZMZ-9S70 0) ZMZ-9S70 Micro count totalizer 0=0 V AC Surface-mounted and =4 V DC Rail-mounted 7-digit display 8= V DC without manual reset 4

6 preset counter with stationary presets The KOBOLD model ZMZ-5V is a 5-digit preset counter with stationery presets. The preset target counter reading is continuously visible and can be set during counting. A floating changeover contact switches when the target value is reached. It remains switched until a button is pushed to manually set it to "0. Production piece counting Automation x Pin sockets Ø.5 mm, silver-plated Pin connector Ø.5 mm, silver-plated Panel cut-out Max. counting frequency: Min. pulse duration: Min. pulse interval: Pulse ratio: 8 s - (AC versions) 5 s - (4 V DC version) 7.7 ms (AC versions) 4 ms (4 V DC version) 7.7 ms (AC versions) 6 ms (4 V DC version) : (AC versions) : (4 V DC version) Maximum display: Display: (counter) Yellow on black background (preset value) 4.5 mm high (counter) 4 mm high (preset value) Manual reset to zero position Ambient temperature: -0 to +55 C (AC versions) -0 to +60 C (DC version) x mm, black plastic Mounting: Panel mounting Switching contact: microswitch, changeover contact Max. switching capacity: 50 V AC, A 4 V DC, A 60 V DC, 0.7 A 5 V DC, 0.4 A 0 V DC, 0. A (resistive load) Electrical connection: Silver-plated pins with pin sockets (counter) and silver-plated flat blade connectors 0.8 x.8 mm : 4 V DC ; 5 / 0 V AC ±0% Test voltage: 000 V AC r.m.s., as per VDE 045 Max. power consumption: Approx. W at 4 V DC Approx..0 VA for AC versions Approximately 0 g Ordering details (example: ZMZ-5V5 0) ZMZ-5V5 preset counter 0=0 V AC Housing x mm =4 V DC 5-digit display with manual reset 4

Electronic Stopwatches

Electronic Stopwatches measuring monitoring analysing 1/100 min; 1/1 s; 1/100 s Power supply: battery Housing material: ABS ; Summary / Split / Lap; Time of day; Memory; Dual measurement; Countdown; Alarm beeper KOBOLD offices

More information

Turbine Wheel Flow Meter/ Monitor for Liquids

Turbine Wheel Flow Meter/ Monitor for Liquids Turbine Wheel Flow Meter/ Monitor for Liquids measuring monitoring analysing Measuring range: -0 L/min water Measuring accuracy: ±.5% f.s. pmax: 00 bar, tmax: 80 C Viscosity range: low viscous Connection:

More information

Preset counters, electromechanical

Preset counters, electromechanical The electromechanical preset counters (with manual reset) boast a robust construction. They are ideal for use in harsh industrial environments as stand-alone counters or as plugin variants in combination

More information

Viscosity-Compensated Flow Meters and Switches

Viscosity-Compensated Flow Meters and Switches Viscosity-Compensated Meters and Switches for Viscous Liquids measuring monitoring analysing Range: Oil 0.01-0.07 to 8-80 L/min Basic accuracy: ±4% f. s. pmax 350 bar, tmax 100 C Viscosity range: 1...540

More information

DTE. Digital Thermometer. battery powered. measuring. monitoring. analysing. O O Universal Pt100 or thermocouple sensors Battery powered

DTE. Digital Thermometer. battery powered. measuring. monitoring. analysing. O O Universal Pt100 or thermocouple sensors Battery powered Digital Thermometer battery powered measuring monitoring analysing DTE O O Universal Pt100 or thermocouple sensors OO Battery powered O O Direct mount, panel mount, or surface mount O O Clear 6 digit alphanumeric

More information

DTE. Digital Thermometer. battery powered. Battery powered. 100 mm stainless steel case (IP 65) Configured C or F. High accuracy MAX / MIN

DTE. Digital Thermometer. battery powered. Battery powered. 100 mm stainless steel case (IP 65) Configured C or F. High accuracy MAX / MIN Digital Thermometer battery powered measuring monitoring analysing DTE Battery powered 100 mm stainless steel case (IP 65) O O Direct, panel, or surface O O Clear 6 digit alphanumeric LCD display Configured

More information

Pulse counters, electromechanical

Pulse counters, electromechanical B 6 / B 8 The standard totalizers B 6 (with manual reset) and B 6, B 8 (without reset) offer a robust construction. They are ideal for use in harsh industrial environments as individual counters or as

More information

DRS. OEM Turbine Flow Sensor. for Liquids

DRS. OEM Turbine Flow Sensor. for Liquids OEM Turbine Flow Sensor for Liquids measuring monitoring analyzing DRS Flow Range 0.6...0.5 GPM Accuracy ±.5% of Full Scale PPO Plastic, Brass, or Stainless Steel Construction Pulse, -0 ma, or Switching

More information

Operating Instructions for Low Volume Rotating Vane Flow Meter. Model: DPL-1P... DPL-1V... DPL-1E...

Operating Instructions for Low Volume Rotating Vane Flow Meter. Model: DPL-1P... DPL-1V... DPL-1E... Operating Instructions for Low Volume Rotating Vane Flow Meter Model: DPL-1P... DPL-1V... DPL-1E... 1. Contents 1. Contents... 2 2. Note... 3 3. Instrument Inspection... 3 4. Regulation Use... 3 5. Operating

More information

Operating Instructions for Low Volume Rotating Vane Flow Meter. Model: DPL-1P... DPL-1V... DPL-1E...

Operating Instructions for Low Volume Rotating Vane Flow Meter. Model: DPL-1P... DPL-1V... DPL-1E... Operating Instructions for Low Volume Rotating Vane Flow Meter Model: DPL-1P... DPL-1V... DPL-1E... 1. Contents 1. Contents... 2 2. Note... 3 3. Instrument Inspection... 3 4. Regulation Use... 3 5. Operating

More information

Compact Vortex Flow Meter for Low Viscosity Liquids

Compact Vortex Flow Meter for Low Viscosity Liquids Compact Vortex Flow Meter for Low Viscosity Liquids measuring monitoring analysing Range: 0.5- to 0-00 L/min Accuracy: ±.5% F.S. pmax 0 bar; tmax 80 C Connections: G...G, NPT... NPT Connection material:

More information

APM-1. Transmitter/Controller. for ph-value, Redox, Standard signals and Temperature

APM-1. Transmitter/Controller. for ph-value, Redox, Standard signals and Temperature Transmitter/Controller for ph-value, Redox, Standard signals and Temperature measuring monitoring analysing APM-1 Compact-Line Measuring range: ph: -2... 16 Redox: -1500... +1500 mv Temperature: Pt100

More information

modlink msdd Front panel interfaces

modlink msdd Front panel interfaces Tight and with full visibility The connecting mechanism of the Modlink MSDD with integrated locking mechanism allows the components to be used under protection class IP65. This protection class prevents

More information

Time Counters mini "h", DC Version

Time Counters mini h, DC Version Type 633-DC Time Counters mini "h", DC Version Type 633.0 Type 633.7 Type 633.8 High shock resistance Miniature dimensions Electrical connections in standard grid Suitable for PCB mounting Machine-solderable

More information

PolluTherm. calculator hous. 2 from hous. 1 until X X X X X* X* M-Bus- M-Bus and 2 2PM pulse inputs X X X X

PolluTherm. calculator hous. 2 from hous. 1 until X X X X X* X* M-Bus- M-Bus and 2 2PM pulse inputs X X X X 1. Use of the option modules There are two different housings with which these same plug-in units can be used namely: Calculator housing 1 (PolluTherm, PolluStat E and PolluFlow 2010) indicated by a lid

More information

Operating Instructions for Differential Pressure Sensor. Model: PMP

Operating Instructions for Differential Pressure Sensor. Model: PMP Operating Instructions for Differential Pressure Sensor Model: PMP 1. Contents 1. Contents... 2 2. Note... 3 3. Instrument Inspection... 3 4. Regulation Use... 3 5. Operating Principle... 4 6. Mechanical

More information

Operating Instructions for Rotating Vane Flow Meter. Model: DRH-...

Operating Instructions for Rotating Vane Flow Meter. Model: DRH-... Operating Instructions for Rotating Vane Flow Meter Model: DRH-... 1. Contents 1. Contents... 2 2. Note... 3 3. Regulation Use... 3 4. Operating principles... 3 5. Instrument inspection... 4 6. Mechanical

More information

Electronic time relays ATI, BTI, SDT and MTI

Electronic time relays ATI, BTI, SDT and MTI MAKING MODERN LIVING POSSIBLE Technical brochure Electronic time relays ATI, BTI, SDT and MTI With their robust design and many built-in functions, electronic timers ATI, BTI, SDT and MTI are ideal for

More information

Electronic SD1, AS 8, ASR 14, ASR 20

Electronic SD1, AS 8, ASR 14, ASR 20 Electronic SD1, AS 8, ASR 14, ASR 20 2 Electronic SD1, AS 8, ASR 14, ASR 20 Contents Page List of contents..................................................... 3 Function and characteristics.........................

More information

Operating Instructions for Digital Thermometers. Model: DTM

Operating Instructions for Digital Thermometers. Model: DTM Operating Instructions for Digital Thermometers Model: 1. Contents 1. Contents... 2 2. Note... 3 3. Instrument Inspection... 3 4. Regulation Use... 3 5. Operating Principle... 4 6. Mechanical Connection...

More information

DPE. Turbine Wheel Flowmeter. for liquids. Measuring ranges: l/min water. Measuring accuracy: ± 2.5 % of full scale

DPE. Turbine Wheel Flowmeter. for liquids. Measuring ranges: l/min water. Measuring accuracy: ± 2.5 % of full scale Turbine Wheel Flowmeter for liquids measuring monitoring analysing DPE Measuring ranges: - 0... 0-70 l/min water Measuring accuracy: ±. % of full scale p max : PN 0, t max : 80 C O O Connection: ½... female

More information

Han R 23. Circular Connector. Certified acc. to DIN EN ISO 9001 in design/ development, production, installation and servicing.

Han R 23. Circular Connector. Certified acc. to DIN EN ISO 9001 in design/ development, production, installation and servicing. Circular Connector Certified acc to DIN EN ISO 9001 in design/ development, production, installation and servicing Data Sheet 0039-4 Circular Connectors Features Size R 23 Outer diameter 26 mm High contact

More information

Operating Instruction for Turbine-wheel Flow Meter. Model: DRS

Operating Instruction for Turbine-wheel Flow Meter. Model: DRS Operating Instruction for Turbine-wheel Flow Meter Model: DRS . Contents. Contents... 2 2. Note... 3 3. Instrument Inspection... 3 4. Regulation Use... 3 5. Operating Principle... 4 6. Mechanical Connection...

More information

DRH. Paddle Wheel Flow Sensor

DRH. Paddle Wheel Flow Sensor Paddle Wheel Flow Sensor measuring monitoring analyzing DRH Compact Size 7 Material Combinations Flow Range: 0.05...0.2 GPM to 0.66...13.2 GPM Frequency, 4-20 ma Transmitters or Compact Electronics Operating

More information

DINALOG A 144 x 36 A1400 Light-Strip Indicator

DINALOG A 144 x 36 A1400 Light-Strip Indicator DINALOG A x 6 A00 Light-Strip Indicator -9-0-0 /.00 Front panel dimensions: x 6 mm Light-strip indicator with 7 high-contrast LEDs Red LED display color Digital display range for portrait format: 999 to

More information

Operating Instruction for Turbine-wheel Flow Meter. Model: DRB-...

Operating Instruction for Turbine-wheel Flow Meter. Model: DRB-... Operating Instruction for Turbine-wheel Flow Meter Model: -... 1. Contents 1. Contents... 2 2. Note... 3 3. Instrument Inspection... 3 4. Regulation Use... 3 5. Operating Principle... 4 6. Mechanical Connection...

More information

Temperature Controller E5C4

Temperature Controller E5C4 Temperature Controller 1/16 DIN Sized, Digital-Set Controller Features Easy-to-Read LED Display Proportional-derivative (PD) control or ON/OFF control models Front panel offset adjustment on PD controllers

More information

PSR-SCP- 24DC/URM4/4X1/2X2/B PSR-SPP- 24DC/URM4/4X1/2X2/B

PSR-SCP- 24DC/URM4/4X1/2X2/B PSR-SPP- 24DC/URM4/4X1/2X2/B Safety Relay as a Contact Extension Block INTERFACE Data Sheet PHOENIX CONTACT - 05/2006 Description The PSR-...- 24DC/URM4/4X1/2X2/B safety relay can be used as a contact extension block in safety circuits

More information

Absolute Encoders Multiturn

Absolute Encoders Multiturn The multiturn encoders 6 and 8, with interface and combined optical and magnetic sensor technology, offer a maximum resolution of 5 bits. These encoders are programmable via the Ezturn software. The hollow

More information

Advant OCS. The Compact and Cost Effective Advant Controller. Advant Controller 210. Open Control System

Advant OCS. The Compact and Cost Effective Advant Controller. Advant Controller 210. Open Control System Advant OCS Open Control System Advant Controller 210 The Compact and Cost Effective Advant Controller Advant Controller 210 is a small, cost-effective system belonging to the Advant Controller family.

More information

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005 Product and Applications Description Application Programs The application programs of the dimmer UP 525/01 consist of two elements: the actuating and the sensor program element. The tasks actuating program

More information

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs Product and Applications Description Example of Operation dimmer UP 525/11 load circuit AC 230 V L1 N The dimmer UP 525/11 is a dimming actuator for mounting in box mounts (a.o. 60 mm Ø, 60 mm depth).

More information

Safety controller unit B1 /

Safety controller unit B1 / Version 1.0 Safety controller unit 470111B1 / For 2 to 16 safety sensors 470115B1 PL d in acc. with EN ISO 13849-1 / SIL CL 2 in acc. with EN IEC 62061 Two safety outputs and external contactor monitoring

More information

Data sheet. CI-TI TM Contactors and Motor Starters Timers ATI, BTI, MTI 520B1307

Data sheet. CI-TI TM Contactors and Motor Starters Timers ATI, BTI, MTI 520B1307 CI-TI TM Contactors and Motor Starters August 2002 DKACT.PD.C00.J2.02 520B1307 Introduction or - star-delta start Multi function electronic timers featuring: - ON delay - OFF delay - single pulse pause

More information

812/ 814/ 815 digital timers

812/ 814/ 815 digital timers 8/ 84/ 85 digital timers 8 84 85 Relay output digital timer Multirange Multivoltage or relay outputs Reset function on panel (imers 85) Data saved in the event of a break in supply (imer 85) Access to

More information

Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3.

Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3. Data Sheet T 6493 EN TROVIS 6400 Automation System TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and

More information

Product and functional description

Product and functional description Product and functional description The RS 525/23 Universal Dimmer is a KNX device with one dimmer output. The device is installed in an AP 118 Control Module Box or an AP 641 Room Control Box. The bus

More information

DATA SHEET. Advanced Energy Meter, AEM 380 & AEM 305

DATA SHEET. Advanced Energy Meter, AEM 380 & AEM 305 DATA SHEET Advanced Energy Meter, AEM 380 & AEM 305 Easy installation MID-approved 5 optional communication interfaces Phase error detection Low power consumption Two tariffs Two-pulse output DEIF A/S

More information

Model 720 Electromechanical Hour Meter

Model 720 Electromechanical Hour Meter Model 720 Electromechanical Hour Meter A 5 figure (reset) or 6 figure (non-reset), AC hour meter encased in a rugged steel housing and designed to mil-spec environmental requirements. The non-reset models

More information

Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates

Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates 1 883 1883P01 1883P02 QFM4160 AQF4150 Symaro Duct Sensors for relative humidity and temperature with calibration certificates QFM41 Operating voltage AC 24 V / DC 1353 Signal output DC 010 V / 420 ma for

More information

RoHS. Shock / vibration resistant. Short circuit proof. Flexible. . XXXX e. . XXXX e

RoHS. Shock / vibration resistant. Short circuit proof. Flexible. . XXXX e. . XXXX e The Sendix multiturn encoders 5862 and 5882, with SSI or RS485 interface and combined optical and magnetic sensor technology, offer a maximum resolution of 25 bits. These encoders are programmable via

More information

02/11/2015

02/11/2015 35 mm - 1 Relay 8A OUR1 Part number 88867105 Multi-function or mono-function Multi-range Multi-voltage Relay output 1 or 2 : 8 A - 250 V (10 A UL) LED status indicator Option of connecting an external

More information

Electronic Preset Counter with 2 Presets and Print interface. NE213 Prog Features

Electronic Preset Counter with 2 Presets and Print interface. NE213 Prog Features Electronic Preset Counter with 2 Presets and Print interface NE21 Prog. 09 Features Order designation Order no. Interface RS22 Models Connection Functions LED-preset counter with 2 presets Batch counter

More information

PSR-SCP- 24DC/SSM/2X1 PSR-SPP- 24DC/SSM/2X1

PSR-SCP- 24DC/SSM/2X1 PSR-SPP- 24DC/SSM/2X1 PSR-SCP- DC/SSM/2X1 PSR-SPP- DC/SSM/2X1 Safety Relay With Downtime Monitoring INTERFACE Data Sheet PHOENIX CONTACT - 05/2006 Description The PSR-...- DC/SSM/2X1 safety relay can be used in safety circuits

More information

Cable distribution systems

Cable distribution systems distribution systems Top-quality cable distribution systems Passive distribution systems are an important part of any machine installation, as they replace costly connection cabinets and error-prone wiring.

More information

This document describes the features and functional specifications of the ECONO3 air conditioner controller.

This document describes the features and functional specifications of the ECONO3 air conditioner controller. TITLE : FUNCTIONAL SPECIFICATION FOR ECONO3 COOL REV : 01 DATE : MARCH 13, 2001. 1. INTRODUCTION 1.1 Scope of Document This document describes the features and functional specifications of the ECONO3 air

More information

Electronic timer CT-AHD.22

Electronic timer CT-AHD.22 2CDC 251 093 F0t06 a Rotary switch for the preselection of the time range b Potentiometer with direct reading scale for the fine adjustment of the time delay c U: green LED V control supply voltage applied

More information

Issue 03/2013. The Electronic Load

Issue 03/2013. The Electronic Load Issue 03/2013 ZS Electronic Loads, PL Series Interface overview RS-232 USB / GPIB LAN System bus Analog X Analog isolated / X Standard ption / not available PL506 PL1006 Voltage Current Resistance 3) Model

More information

Classification Enclosure rating Input voltage Type of

Classification Enclosure rating Input voltage Type of Slim Relay G2RV The World's First Industrial Slim Relay Large plug-in terminals for reliable connection. LED indicator and mechanical flag to check operation. Special input type with gold plated contacts.

More information

FP-PS-4. Features. Installation

FP-PS-4. Features. Installation OPERATING INSTRUCTIONS FP-PS-4 FieldPoint Power Supply These operating instructions describe the installation, features, and characteristics of the FP-PS-4. Features The FP-PS-4 is a FieldPoint power supply

More information

Unaffected by Angle, Colour, or Dirt

Unaffected by Angle, Colour, or Dirt Cat No. PZ-C2 Unaffected by Angle, Colour, or Dirt Introducing Multi-reflective Photoelectric Sensors PZ-V Provide Solutions to All the Problems Experienced with Conventional Reflective Types. Conventional

More information

EAO Your Expert Partner for Human Machine Interfaces. EAO Product Information. Series 19

EAO Your Expert Partner for Human Machine Interfaces. EAO Product Information. Series 19 EAO Your Expert Partner for Human Machine Interfaces EAO Product Information Series Switches and Indicators Contents Description... 3 Product Assembly... 4 Devices raised mounting... 5 Accessories...

More information

RE48ATM12MW on-delay timing relay s..300 h V AC - 2 OC

RE48ATM12MW on-delay timing relay s..300 h V AC - 2 OC Characteristics on-delay timing relay - 0.02 s..300 h - 24..240 V AC - 2 OC Product availability : Stock - Normally stocked in distribution facility Price* : 73.00 USD Main Range of product Product or

More information

Slim Relay G2RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. Relay and Socket Combinations

Slim Relay G2RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. Relay and Socket Combinations Slim Relay G2RV The World's First Industrial Slim Relay Large plug-in terminals for reliable connection. LED indicator and mechanical flag to check operation. Transparent housing enables checking relay

More information

02/11/2015

02/11/2015 DIN Rail Mount 22.5 mm TU2R1 Part number 88865305 Product with 1 relays (88 865 100/103/105/115/125/135/145/155/185/503) : Replaced by the 17,5 mm range For instance : previous part number 88 865 XXX /

More information

VEO. V2ZR V AC/DC Art.Nr.: V2ZR10P V AC/DC Art.Nr.: TECHNICAL DATA

VEO. V2ZR V AC/DC Art.Nr.: V2ZR10P V AC/DC Art.Nr.: TECHNICAL DATA Off-Delay 10 time ranges Supply voltage 24-240V AC/DC 1 change-over contact Width 22,5 mm Control elements Fine adjustment Setting of time range Status indication LED U/t: Supply voltage LED R: Relay status

More information

Room sensors QFA4160 QFA41 D AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

Room sensors QFA4160 QFA41 D AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates 1 859 1859P01 1859P02 1859P04 QFA4160 QFA41 D AQF4150 AQF3153 Symaro Room sensors for relative humidity and temperature with calibration certificates QFA41 Operating voltage AC 24 V / DC 13.5...3 Signal

More information

GS202 Encoder Switch

GS202 Encoder Switch GS202 Encoder Switch 20:2 encoder switch 20 encoder inputs (TTL / RS422 standard) Input signals A, /A, B, /B, Z, /Z on each encoder input 2 x 6 control inputs (HTL / PNP) 2 encoder outputs (TTL / RS422

More information

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING Product and Applications Description Note If the application program is not loaded completely by the ETS, you had better interrupt the 24 V voltage supply of the I/O-module during the loading interval.

More information

Immersion Temperature Sensors

Immersion Temperature Sensors 1 782 1782P01 Symaro Immersion Temperature Sensors QAE2164 QAE2174 Active sensors for acquiring the water temperature in pipes and tanks Operating voltage AC 24 V or DC 13535 V Signal output DC 010 V or

More information

SM9000. Made in Germany

SM9000. Made in Germany Made in Germany Product characteristics Magnetic-inductive flow meter Connector Process connection: G2 flat seal connection to pipe by means of an adapter Function programmable Totaliser function Empty

More information

Cable distribution systems

Cable distribution systems Cable distribution systems Top-quality cable distribution systems Passive distribution systems are an important part of any machine installation, as they replace costly connection cabinets and error-prone

More information

More Precision. wiresensor // Draw-wire displacement sensors

More Precision. wiresensor // Draw-wire displacement sensors More Precision wiresensor // Draw-wire displacement sensors 22 Low-cost draw-wire displacement sensors wiresensor MK88 analog - Robust plastic housing - Customized versions for OEM - Potentiometer, current

More information

VEO. V2UF230V10 Art.Nr.: TECHNICAL DATA

VEO. V2UF230V10 Art.Nr.: TECHNICAL DATA Continous voltage monitoring Mains fluctuation detection Detects voltage drop / short interruptions of at least 10ms Prevents undefined states in switching and control systems Generates reset pulse after

More information

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA Monitoring of phase sequence and phase loss Monitoring of asymmetry Supply voltage 208-480 V AC Supply circuit = measuring circuit 1 change-over contact Width 22,5 mm Control elements Asymmetry Status

More information

Operating Instructions VEGAMET 381

Operating Instructions VEGAMET 381 Operating Instructions VEGAMET 381 in out Contents Contents 1 About this document... 4 1.1 Function... 4 1.2 Target group... 4 1.3 Symbolism used... 4 2 For your safety... 6 2.1 Authorised personnel...

More information

Field Terminal Assembly (FTA)

Field Terminal Assembly (FTA) FTA-C300 Brochure Field Terminal Assembly (FTA) New interfaces for the Honeywell Experion PKS C300 controller Weidmüller s new interfaces and pre-assembled cables allow you to wire up I/O cards from Honeywell

More information

08/07/2015

08/07/2015 DIN Rail Mount 22.5 mm TUR1 Part number 88865105 Product with 1 relays (88 865 100/103/105/115/125/135/145/155/185/503) : Replaced by the 17,5 mm range For instance : previous part number 88 865 XXX /

More information

Operating Instruction for rotating vane flow meter Model: DPM-...

Operating Instruction for rotating vane flow meter Model: DPM-... Operating Instruction for rotating vane flow meter Model: PM-... 1. Note Please read and take note of these operating instructions before unpacking and setting the unit for operation, and follow the instructions

More information

Electronic timer CT-ERD.12

Electronic timer CT-ERD.12 2CDC 251 092 F0t06 a Rotary switch for the preselection of the time range b Potentiometer with direct reading scale for the fine adjustment of the time delay c U: green LED V control supply voltage applied

More information

IST ULTRASTAB Power Supply for high precision transducers

IST ULTRASTAB Power Supply for high precision transducers IST ULTRASTAB Power Supply for high precision transducers High performance 6-channel power supply for multi-channel laboratory measurement applications. Features Current output or ±0 V voltage output (see

More information

Electronic timer CT-EAS ON-delayed and OFF-delayed with 1 c/o contact Data sheet

Electronic timer CT-EAS ON-delayed and OFF-delayed with 1 c/o contact Data sheet 2CDC 251 116 F0004 1 5 2 4 3 6 Characteristics Single-function ON-delay and OFF-delay timer One device includes 10 time ranges, from 0.05 s to 300 h, for the adjustment of the time delay Remote potentiometer

More information

MEASURING AND TESTING INSTRUMENTS

MEASURING AND TESTING INSTRUMENTS MEASURING AND TESTING INSTRUMENTS Whether measuring temperature, current or voltage testing the right measuring tool can facilitate the everyday work. If one wants to perform several measuring tasks at

More information

Operating Instructions for Level Switch for Liquids. Model: RFS

Operating Instructions for Level Switch for Liquids. Model: RFS Operating Instructions for Level Switch for Liquids Model: RFS 1. Contents 1. Contents... 2 2. Note... 3 3. Instrument Inspection... 3 4. Regulation Use... 3 5. Operating Principle... 4 6. Use in Hazardous

More information

Digital Frequency Divider INSTRUCTION MANUAL CONTENTS. 1. Working Principle Installation Setting Up Technical Data 4.

Digital Frequency Divider INSTRUCTION MANUAL CONTENTS. 1. Working Principle Installation Setting Up Technical Data 4. Digital Frequency Divider INSTRUCTION MANUAL CONTENTS 1. Working Principle 2 2. Installation 2 3. Setting Up 3 4. Technical Data 4 Code: 189/1a 1 WORKING PRINCIPLE The DFD has been designed to generate

More information

DATASHEET ULTRASONIC COMPACT ENERGY METER MODEL 773

DATASHEET ULTRASONIC COMPACT ENERGY METER MODEL 773 APPLICATION Static compact energy meter using ultrasonic technology Highly accurate recording of all billing data in local and district heating and cooling systems FEATURES 1st. approval in Europe for

More information

INSTRUCTION MANUAL FOR THE MC-01 CONTROL UNIT

INSTRUCTION MANUAL FOR THE MC-01 CONTROL UNIT 1 INSTRUCTION MANUAL FOR THE MC-01 CONTROL UNIT TABLE OF CONTENTS 1 INSTALLATION... 2 1.1 Mounting... 2 1.2 Mains Connection... 2 1.3 Relay Connection... 3 1.4 Pulse Input Connection... 3 1.5 4-20 ma Output

More information

Miniature PCB Relays A

Miniature PCB Relays A SЕRIES Miniature PCB Relays 8-10 - 12-16 Medical and dentistry Control panels Panels for electrical distribution Toys utomation for blinds, grilles and shutters Door and gate openers Electronic circuit

More information

93 SERIES. Timed socket for 34 series 93.68/93.69

93 SERIES. Timed socket for 34 series 93.68/93.69 93 93 Slim timed sockets for 34 series, 6.2 mm wide Timer adjustment via top mounted rotary knob accessible after assembly Control signal terminal DIP-switch for selection of 4 time scales and 8 functions

More information

Compact Coded Magnetic Safety Interlock Switch and Control Units

Compact Coded Magnetic Safety Interlock Switch and Control Units C Conforms to EN292, EN60204-1, EN954-1, EN1088, EN60947-5-3, EN947-5-3, EN50081, EN50082, EN61000-6-2 UL and C-UL listed, TUV certified Description R US Compact Coded Magnetic Safety Interlock Switch

More information

DATA SHEET. Advanced Power Meter, APM 380 & APM 305

DATA SHEET. Advanced Power Meter, APM 380 & APM 305 DATA SHEET Advanced Power Meter, APM 380 & APM 305 Easy installation Monitors all 3 phases 5 optional communication interfaces Phase error detection Low power consumption Two-pulse output DEIF A/S Frisenborgvej

More information

CLASS 1 DIVISION 2 PRODUCTS

CLASS 1 DIVISION 2 PRODUCTS CLASS 1 DIVISION 2 PRODUCTS CLASS 1 DIVISION 2 PRODUCTS UPDATED PRODUCT INFORMATION Class 1 Division 2 Products Non-Incendive Barriers Two non-incendive barriers are available - one for 24Vdc discrete

More information

Product and functional description

Product and functional description Product and functional description The UP 525/13 Universal Dimmer is a KNX device with one dimmer output. The device is installed in a flushmount wall box (60 mm Ø, depth 60 mm) or an installation box.

More information

More Precision. wiresensor // Draw-wire displacement sensors

More Precision. wiresensor // Draw-wire displacement sensors More Precision wiresensor // Draw-wire displacement sensors 24 Low-cost draw-wire displacement sensors wiresensor MK analog - Robust plastic housing - Customized versions for OEM - Potentiometer, current

More information

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B 3 136 Synco 700 Extension odules for heating controller RH760B RZ782B RZ783B Extension modules for use with the RH760B heating controller to provide additional auxiliary functions Use Heating plants controlled

More information

Product and functional description

Product and functional description Product and functional description The RS 520/23 shutter / blind actuator is a KNX device with one relay output. The device is installed in an AP 118 Control Module Box or an AP 641 Room Control Box. The

More information

Electronic timer CT-VWD Impulse-ON with 1 c/o contact Data sheet

Electronic timer CT-VWD Impulse-ON with 1 c/o contact Data sheet Electronic timer CT-WD 2CDC 251 003 F0003 CT-WD 6 5 1 2 3 4 1 7 selectable time ranges, from 0.05 s to 100 h, for the adjustment of the pulse time 2 Potentiometer with direct reading scale for the fine

More information

animeo IB+ Motor Controller WM 4DC/E

animeo IB+ Motor Controller WM 4DC/E animeo + Motor Controller WM 4DC/E Installation guide The animeo 4 DC/E Motor Controller 220-240 V AC is designed to control motors of the concept 25 motor range (24 V DC) 2006, SOMFY SAS. All rights reserved.

More information

Displays Transducers. Displays and transducers

Displays Transducers. Displays and transducers JJ Displays JJ Transducers Displays and transducers DS_Displays_and_transducers 06/2016 225 Displays and transducers Our electronic devices for flow and volume measurement are suitable for all SIKA flow

More information

Controller module. Brief description. Features. Block structure. Page 1/7. Data Sheet

Controller module. Brief description. Features. Block structure. Page 1/7. Data Sheet JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net

More information

VENTILATION BUTTONS 24 V DC

VENTILATION BUTTONS 24 V DC VENTILATION BUTTONS 24 V DC Ventilation button (with foil push buttons and displys) Application: Ventilation button for connection to the ventilation inputs of SHEV or natural ventilation control units.

More information

Dual Channel Monitor for Measurement of Speed and Ratio with SIL1 requirements Series D224.xx

Dual Channel Monitor for Measurement of Speed and Ratio with SIL1 requirements Series D224.xx D224 Dual Channel Monitor for Measurement of Speed and Ratio with SIL1 requirements Series D224.xx D224 Front View KEY FEATURES SIL1 / IEC 61508:2010 compliant Dual Channel Speed and Ratio Monitor with

More information

IST ULTRASTAB Power Supply for IT/ITN ULTRASTAB transducers

IST ULTRASTAB Power Supply for IT/ITN ULTRASTAB transducers Power Supply for IT/ITN ULTRASTAB transducers High performance 6-channel power supply for multi-channel laboratory measurement applications. Features Current output or ±10 V voltage output Six individual

More information

Assembly. Front view. LED yellow: Relay output I. LED yellow: Relay output II

Assembly. Front view. LED yellow: Relay output I. LED yellow: Relay output II Switch Amplifier, Timer Relay Features 1-channel signal conditioner Universal usage at different power supplies 3-wire PNP/NPN sensor or push-pull input 2 relay contact outputs Adjustable energized/de-energized

More information

Process displays For current and voltage

Process displays For current and voltage Features Voltage input TRMS-AC/DC up to 600 V Current input AC/DC 1 A, 5 A and shunt (precision resistor) 60 or 100 mv With 2 or 4 limits Display range can be linearised Min, Max, Hold functions 4 20 ma

More information

Installation / Control Technique

Installation / Control Technique Installation / Control Technique Interface Relay, Interface Relay System Input-Output Interface Relay IK 3070, I_ 3070 0633 IK 3070 Circuit Diagrams IS 3070 According to IEC/EN 61 810-1 Relay, triac or

More information

Control elements. Fine adjustment. Status indication. 24 V DC typ. 0,25 W / 0,25 VA. 24 V DC typ. 0,03 W / 0,09 VA. 0,15 3 s. 0,5 10 h.

Control elements. Fine adjustment. Status indication. 24 V DC typ. 0,25 W / 0,25 VA. 24 V DC typ. 0,03 W / 0,09 VA. 0,15 3 s. 0,5 10 h. On-Delay 10 time ranges Supply voltage 24-240V AC/DC 1 change-over contact Width 22,5mm Control elements Fine adjustment Setting of time range Status indication LED U/t: Supply voltage LED R: Relay status

More information

Switching relay CT-IRS with 1, 2 or 3 c/o contacts Data sheet

Switching relay CT-IRS with 1, 2 or 3 c/o contacts Data sheet 1SVR 430 221 F7300 2 1 3 Characteristics Switching relay ON-delay approx. 10 ms 1, 2 or 3 c/o contacts Switching relay with gold-plated contacts Width 22.5 mm Approvals e f GOST CCC CT-IRS 1 U/R: green

More information

PointMaster 100. Multipoint Recorder 10/ EN

PointMaster 100. Multipoint Recorder 10/ EN PointMaster 1 Multipoint Recorder 1/41-1.1 EN 6 Measuring channels Last dot visible from the front Measuring channels electrically isolated and ungrounded Connection of process signals / 4...2 ma,...1

More information

Controller module. Brief description. Features. Block structure. Data Sheet Page 1/7

Controller module. Brief description. Features. Block structure. Data Sheet Page 1/7 M. K. Juchheim GmbH & Co UK USA Jumo Instrument Co. Ltd. Jumo Process Control Inc. 36035 Fulda, Germany Temple Bank, Riverway 735 Fox Chase Phone (0661) 6003-0 Harlow, Essex CM20 2TT Coatesville, PA 19320

More information