Fieldbus Connectivity

Size: px
Start display at page:

Download "Fieldbus Connectivity"

Transcription

1

2 Fieldbus Connectivity busstop Overview Connector Specifications Pre-molded Fieldbus Cables Part Number Keys FOUNDATION Fieldbus Overview Cable and Cordsets Junctions (Bricks) Device Glands Terminating Resistors Tees and Adapters Surge Suppressor, Power Conditioner and Lokfast Guard Receptacles Field Wireables and Accessories PROFIBUS -PA Overview Cable and Cordsets Junctions (Bricks) Device Glands Terminating Resistors Tees and Adapters Surge Suppressor and Lokfast Guard Receptacles Field Wireables and Accessories HART Overview Cable and Cordsets Junctions Device Glands Tees and Adapters Receptacles Field Wireables and Accessories Installations Index of Components Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

3 A Worldwide Fieldbus Solution InterlinkBT BT - A Banner-TURCK Bus Products Company is a joint venture between two renowned sensor companies, TURCK, Inc. and Banner Engineering, to focus specifically on bus products. The experience and advanced bus technologies of these companies are now combined, resulting in the industry s broadest, most complete line of stations, junctions, cordsets and components for device-level networks. is the industry s bus I/O specialist and leading supplier of top-quality bus products. Most importantly, is your best solution to connect input/output devices to open buses. InterlinkBT BT S Fieldbus Connectivity Catalog This catalog covers high quality on-the-machine and at-the-process FOUNDATION fieldbus H1, PROFIBUS -PA and HART interconnect products. The product offering emphasizes materials for diverse applications where aggressive environments are often the norm. Cable has the products for interconnecting all your devices on a network segment. By simply plugging components together these products allow for quick installations of new plant layouts and easy alterations to existing installations. InterlinkBT s junction blocks are rugged and can be mounted in aggressive environments. Spur or drop count can vary from 4 to 8 with the choice of minifast or eurofast connector sizes. cable exceeds ISA SP50.02 specifications for impedance and attenuation. Pre-molded cordsets are available with either minifast or eurofast connector sizes. The easy-to-use terminating resistor simply screws into the end of the Home Run cable. You can reliably use fieldbus products in the harshest of environments Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

4 Connectors t all the I/O in a fieldbus system can be connectorized, but when it can it is extremely effective. A few minutes of layout and bill-of-material planning can replace hours of costly wire installation. In addition, product replacement is greatly facilitated by using industrial grade quick disconnect plug-and-play receptacles. 1 uses two industrial standardized connectors. The generic names for them are Mini and Micro or Euro. In one variation or another these two standardized connectors are produced by the thousands. Rough estimates put the Mini style at over 10,000 per day and the Euro at over 25,000 per day. They are used in every industry that requires rugged economic plug-and-play connectorization. Both were standardized by DIN (German Industrial Standards) in their early design. Today they are recognized standards throughout the world. The sheer volume means that the build processes for these two standards are understood, tooled, automated and economical. The volume and breadth of applications means that broad selections of off-the-shelf products are available. There are three materials for coupling nuts; stainless steel, nylon and nickel-plated brass. The mating pin and sleeves are gold-plated brass. The body is made of polyurethane and is injection molded to the cable jacket to provide strain relief and to seal the connections from the atmosphere. The Mini s pin and sleeve are rated at 9 amps and the Micro is rated at 4 amps. The designated ground pin of the Mini family is longer than the other pins, resulting in a make-first/break-last ground. This feature is not explicitly required for IS or NI applications, but is a sound engineering choice. All the pins of the Euro make and break at the same time during insertion and removal. Junction Boxes The junction boxes shown in this catalog are passive hubs. Although no conditioning or monitoring takes place, some junctions have short circuit protection. This protects the power on the trunk and allows use in Class 1, Div 2 locations. The boxes are made from two different materials; copper-free die-cast aluminum with a powder coated enamel finish or polyurethane overmold. Both housings are available with either 316 stainless steel or nickel plated brass connectors. The junction boxes are rated NEMA 1, 3, 4, 4X, 12, 13 and IEC IP67. These ratings are conditional, requiring the cordset or cap to be installed. Although the die cast housing is rated 4X (salt-water spray test) we highly recommend the polyurethane or fiberglass housing for aggressive environments Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

5 Occupants on the Bus Active Hub - a multiple port repeater or amplifier that lengthens the branching ability of a bus. Barrier Box - limits current/voltage to an area. Brick - fully connectorized passive junction. Bridge - there are two types; one is a double-sided node that connects two segments together that are the same protocol but different transmission speeds, the other is a smart repeater that only repeats the data between two bus segments when the source and destination address are in different segments. The bridge must be programmed to know what the addresses are and their respective segments. Bus Junction - generic name for a passive hub. Busline - any group of wires that carries data from node-to-node. Dropline - a reduced branch (spur) from a trunkline. Gateway - a special node on two different buses that serves as a signal and data translator between the buses. LAS (Link Active Scheduler) - controls communication on the bus. Creates a token circulation list (Live List) that defines access on the bus. Devices may only communicate when given access by the LAS unit. Multiple devices may have LAS capabilities but only one can communicate at a time. de - an addressable device on the bus. Power Conditioner - device used to condition the power to be for a bus segment. Allows power and data to exist on the same wires. Repeater - a product that strengthens a signal, while adding up to a half-bit wait state and producing a fresh signal without distortions. It also links two portions of the same bus together. A repeater is used when a signal is weak or distorted. Router - a higher level bridge for connection of wide area networks. Simple Device - anything that does not have LAS capabilities. System Tee ee - a field wireable tee. Tee ee - a product that creates a branch or drop from a bus. Terminating resistor - a resistor that is put at the beginning and end of the main busline to stabilize and minimize reflections. Trunk line - the main busline. To Control Highway Fieldbus I/O Host 24V 24V Main Trunk Cable Main Trunk Cable Spurs Terminator BRPS-49-M213 JTBS-49SC-M633 Pressure Transmitter Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

6 Bus Topology Topology is a term that applies to buses. It describes how the data lines connect the nodes together. The first bus goes back to the original telegraph - two data lines hanging on wooden poles going from telegraph station to telegraph station. 1 Bus - the simple straight-line topology is called a bus. Another term used is Daisy Chain, where the trunk simply runs from device to device. Branch - a common bus can have branches, and sometimes the branches can have branches. Another term used to describe the branches is drops or spurs, as in FOUNDATION fieldbus. Depending on the bus the branches may be restricted to just a few centimeters or a free-form topology with restrictions only on the cumulative distance of all data lines. Star - the bus lines radiate from a single point. A junction (either passive or active) looks like a star. FOUNDATION fieldbus also refers to this as a chicken foot topology with many branches connected in a relatively small area Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

7 Bus Types There are several different bus types utilizing the following technologies: Client / Server - upload/download information, setpoint changes, alarm management, remote diagnostics and one to one communications. Media Access - this is the right-of-way for talking on the bus. There are three main types: Master Control - one super node controls all transmission, sequence and time. Remaining nodes do not talk unless told to by the master. Token Passing - this is a message shift method that is incremented in a manner that allows each node a chance to talk during each cycle. CSMA - an access method allowing each node to speak, provided that it has something to say and no other node is talking on the line. Message Collision Avoidance - when two people talk simultaneously there is a verbal collision. A few humans can talk and listen to someone else at the same time but nodes cannot. Both token passing and master control do not have that problem. A field node can only access the bus when it is its turn to talk or when it has been told to talk. CSMA-type buses do have this problem. The problem goes away when they are operated as a master-to-slave. When operating in the native CSMA access method two nodes could start talking simultaneously. Two major ways have been developed to handle a potential collision: CD - collision detection - all senders must also be receivers. If two nodes start talking at the same time they will hear a collision. Both stop talking, wait a random length of time, then look for a clear line to start talking again. BA - bitwise arbitration - all senders must also be receivers. The busline must be of a specific length or less so that all nodes hear the bit at the same time (actually the first node and the last node can be approximately 1/6 bit apart). Messaging - there are three major types in the run mode, but many more during start-up and initialization. Solicited - a response to another node or a response when it is the node s predetermined time to speak (token passing). Unsolicited - a response to a change-of-state at the node. Explicit - a command order. It may command an output be turned On or Off. It may command any node to report its diagnostic status or identity itself in full detail. One last distinction must be made for the output nodes. How do they get the information so they know what to do? Although there is an overlap with the terms used for messaging, there are important differences: Explicit Message - this is a command from another node. Limited Peer-to-Peer - exclusive one-to-one relationship between the input node and the output node. This could also be called exclusive peer-to-peer. Unlimited Peer-to-Peer - similar to limited peer-to-peer, but the output node may get information from several input nodes. Publisher / Subscriber - scheduled distribution of data to nodes on the subscriber list Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

8 minifast Connector - 7/8-16UNF thread -100% electrically tested -Meets: SAE H Current Rating: 9A -Voltage Rating: 300V -Protection: NEMA 1,3,4,6P IEC IP67 -NEMA 4X with stainless steel coupling nuts -Temperature: -30ºC to +85ºC -Oscillation: 65mm (2.5in.) to 125mm (5in.) -Pull Strength: 100 lbs - 5 to 12.5 cycles/sec. for 2 million cycles Connector Specifications eurofast Connector -M12 x 1 thread -100% electrically tested -Meets: IEC Current Rating: 4A -Voltage Rating: 300V -Protection: NEMA 1,3,4,6P and IEC IP67 -NEMA 4X with stainless steel coupling nuts -Temperature: -30ºC to +85ºC -Vibration: 10 to 500 Hz and 0/35mm or 5g -Pull Strength: 50 lbs 1 multifast Connector - M23 x 1 thread -100% electrically tested -Current Rating: 4A -Voltage Rating: 300V -Protection: NEMA 1,3,4,6P IEC IP67 -Temperature: -30ºC to +85ºC 3000 Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

9 Pre-molded Fieldbus Cables Pre-molded fieldbus cables ensure simple and secure wiring of the connected fieldbus components. Time-consuming wiring of individual components and bus communication problems due to wiring errors or incomplete shielding are eliminated. Molded polyurethane insulation provides IP67 protection. Standard lengths of pre-molded cordsets and bulk cable are listed below. Consult the factory for other lengths. Standard d Cable Lengths Cordsets Bulk Cable meters feet meters feet Other lengths available upon request. Unit Conversions: 1 meter = 3.28 feet 1 meter = inches Tolerances: +50/-0 mm or +4% of length which ever is greater Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

10 eurofast Part Number Keys Cordsets R S C V 49 x *M 1 R W = Straight = Right Angle Length in Meters (*) Standard 0.3, 0.5, 1, 1.5, 2...(see page 8) Consult factory for other lengths Gender S K = Male Connector = Female Connector Cable Type (x) 48 x (see page 51) 49 x (see page 17) H4 x (see page 79) Designator for eurofast Coupling Nut Material V (Blank) = Stainless Steel = Nickel-Plated Brass Receptacles F S F V 49 x *M Designator for eurofast Length in Meters (*) Standard 0.3, 0.5, 1, 1.5, 2...(see page 8) Consult factory for other lengths Gender S K = Male Connector = Female Connector Cable Type (x) 48 x (see page 51) 49 x (see page 17) H4 x (see page 79) Designator for Receptacles Coupling Nut Material V (Blank) = Stainless Steel = Nickel-Plated Brass 3000 Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

11 minifast Part Number Keys Cordsets W K M 4 9 x *M R W = Straight = Right Angle Length in Meters (*) Standard 0.3, 0.5, 1, 1.5, 2...(see page 8) Consult factory for other lengths Gender S = Male Connector K = Female Connector Cable Type (x) 48 x (see page 51) 49 x (see page 17) H4 x (see page 79) Coupling Nut Material M V (Blank) = Nickel-Plated Brass = Stainless Steel = PA 6.6 (Nylon) Receptacles R K F V 4 9 x *M R = Straight Length in Meters (*) Standard 0.3, 0.5, 1, 1.5, 2...(see page 8) Consult factory for other lengths Gender S = Male Connector K = Female Connector Designator for Receptacles Cable Type (x) 48 x (see page 51) 49 x (see page 17) H4 x (see page 79) Coupling Nut Material V P = Stainless Steel = Nickel-Plated Brass Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

12 Junction Tee ee Part Number Key J T B S 4 9 SC M Connector Material 3 4 = Stainless Steel = Nickel-Plated Brass JT = Junction Tee JB = Junction Box Housing 1 = Aluminum (JBBS only) 2 = Fiberglass (JBBS only) 3 = Polyurethane (JTBS only) 4 = Hytrel (JTBS only) Number of Ports 4 = 4 ports 6 = 6 ports 8 = 8 ports Bus System 48 = PROFIBUS -PA 49 = FOUNDATION fieldbus Connector Type M = minifast E = eurofast Protection SC (Blank) = Short Circuit = ne 3000 Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

13 For HART Systems Only HAR ART Junction Box Part Number Key V B M 4 0 H C S V 1 2 Housing VBM - Metal Housing eurofast Connectors 4MB12 - Nylon Housing or eurofast 8MB12 Connectors JTBS - Polyurethane Housing minifast Connectors Number of Ports 40-4 ports 60-6 ports 70-7 ports 80-8 ports HAR ART Topology H - HART Point-to-Point HM - HART Multidrop Home Run Connector CS12 - multifast 12-pin CSV12* - multifast 12-pin CSV19* - multifast 19-pin CS19 - multifast 19-pin RS - minifast 5-pin RSV* - minifast 5-pin with *stainless steel coupling nut Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

14 1 FOUNDA OUNDATION TION TION fieldbus Cables and Accessories Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

15 FOUNDA OUNDATION TION fieldbus Overview FOUNDATION fieldbus is a communication protocol and defined physical method to interconnect smart devices such as temperature transmitters, pressure transmitters and valve actuators. The physical layer conforms to ISA SP50.02 and IEC standards for fieldbuses. In comparison to 4-20 ma loops that only allow for one device connection per twisted pair, fieldbus technology enables many smart devices to share one communication medium. The digital communication signal is superimposed onto a DC carrier. This greatly reduces the amount of terminations needed to connect all the field devices to a host system. It also allows greater flexibility for future additions of I/O points. A FOUNDATION fieldbus device is addressable and has capabilities to store and transmit data. The devices can store values, track changes and use pre-set alarms to trigger. Based on pre-defined tag names, host systems can read transmitter values such as temperature and pressure or set values of a valve actuator. The digital signal encoding is done using Manchester BiPhase-L and error checking is done with the CRC method. FOUNDATION fieldbus has two types of devices; a Basic Device (BD) and a Link Active Scheduler (LAS). A Basic Device is designed to read inputs, track values and set outputs if programmed to do so. A LAS device performs the same features as a BD, however it goes one step further by handling network communication timing between all the active devices on the network. The LAS essentially creates a time table so that all devices can get a chance to transmit/receive data on the bandwidth. A fieldbus segment can have many Basic Devices but must have at least one Link Active Scheduler. At least two LAS devices are recommended on the network to provide redundancy. If there is more than one LAS on the network, the one that powers-up first gets the LAS designation and the other LAS unit switches to BD mode of operation. General Layout Topologies In essence, all devices on a fieldbus segment are connected in parallel. See Figure e 1 for an example. All transmitters connected to the fieldbus segment listen to all communication signals, however the protocol determines the rules as to which devices respond to the messages. For the purpose of this guide only the physical layout will be discussed in detail. The general layout is either a star (chicken foot) or daisy chain. 93.3FM Figure 1 Parallel Wiring Diagram Figure 1 - Parallel Wiring Diagram Communication Signal The FOUNDATION fieldbus H1 communication signal is a square waveform superimposed on a DC carrier. The frequency of the signal is 31.25Khz. Although they do not have to, most devices derive their supply power from the fieldbus communications cable. The fieldbus specification states that devices must not be polarity sensitive. It is good electrical practice though to have all devices wired with the same polarities. The voltage range allowed for proper operation is 9-32 VDC. A typical fieldbus device will consume 20 ma of current Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

16 Star Topology Method A star topology has a central connection point for all terminations. This layout works well when there are many devices in a localized area. For instance, the control room may be located about 300 meters away from a cracker tower. This tower may have five or six temperature transmitters. All of these devices need to be connected to the fieldbus segment. The best design would be to connect them all to a junction brick and then run a home run cable from the junction brick back to the control room. See Figure 2 for a pictorial example. The Home Run cable is considered the main trunk line for communication. Each device that is connected to the junction brick is called a spur. In other industrial networks spurs are called drops off the trunk line. 2 Figure 2 - Star Topology Example Daisy Chain Configuration In a daisy chain configuration each device would require a tee so that the Home Run cable would be able to go to each device. From a design standpoint, the Daisy Chain method is easiest to do when the exact cable tracks are known. Pre-made cordsets can then be purchased, making the network easy to assemble. See Figure e 3 for an example drawing. A fieldbus transmitter is connected to each of the tanks in the field. The Home Run cable essentially is routed to each device in series. Figure 3 - Daisy Chain Layout Transmitters In many fieldbus installations it makes sense to mix both Star and Daisy Chain topology layouts. The key to the wiring design is to make layouts valid per the fieldbus specifications. One of the benefits to fieldbus is reduced wiring of devices, leading to faster start-up times Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

17 Fieldbus Cable Specifications The specifications for fieldbus H1 physical media are defined by IEC and the ISA-S50.02 Part 2 Physical Layer Standards. The same standard is also listed in the FOUNDATION fieldbus specifications under Kbps Physical Layer Profile FF There are essentially four types of cable designations for fieldbus. Type A cable is the most preferred for new installations because it allows for the most versatile lengths. The other types of cable are for installations where cable already exists from 4-20 ma systems. See Table 1. Type Cable Description Conductor Size Maximum Length Type A Shielded, Twisted Pair # 18 Awg 1900 m (6232 ft) Type B Shielded, Multi Twisted Pair # 22 Awg 1200 m (3936 ft) Type C Unshielded, Multi Twisted Pair # 26 Awg 400 m (1312 ft) Type D Shielded, Untwisted Pair # 16 Awg 200 m (656 ft) Table 1 - Fieldbus Cable Specifications offers cables with both two conductors and three conductors, with the third conductor available for a centralized ground of devices if needed. cables meet or exceed the specifications of ANSI/ISA-SP , the fieldbus standard for use in industrial control systems. The maximum spur length is determined by the number of devices in the segment. Cable Trunk Number of Devices Maximum Spur Length 0 m (0 ft) 30 m (98 ft) 1900 m m (197 ft) 90 m (295 ft) 120 m (394 ft) Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

18 FOUNDA OUNDATION TION fieldbus - Cable Specifications Our cable meets the requirements of ISA/SP50 and FOUNDATION fieldbus requirements for Type A cable. Cables are available in 3-wire versions with a device ground or 2-wire versions. 1 2 Cable Specifications Type A Cable - Temperature range: -40 to 105 C (-40 to +221F) 11 - Governed by: ISA SP50.02 specification - Sunlight resistant - PLTC and ITC rated (CSA FT4) - Impedence[Z 0 at f r (31.25 khz)] = 100Ω ± 20% - Maximum attenuation at 1.25 f r (39 khz) = 3.0 db/km - Maximum capacitive unbalance to shield = 2 nf/km - Maximum DC resistance (per conductor) = 24 Ω/km - Maximum propagation delay variance f r to 1.25 f r = 1.7 µs/km - Conductor cross-sectional area (wire size) = nominal 0.8 mm 2 (#18 AWG) or 1.2 mm 2 (#16 AWG) - Minimum shield coverage shall be 90% Type Approvals AWG Color Code Data Pair DCR (/1000 ft) Insulation Device Ground AWG Color Code Outer Jacket Material Color minal O.D. Shields Type Drain Wire Bulk Cable Part. Ref C 300V NEC ITC PLTC CEC [CMG] 2/18 AWG Blue/Brn 6.5 Ohms PE 18 AWG Green/Yellow PVC Yellow 7.9mm (.310 in) Foil 20 AWG RB50693-*M 1 490B 105 C 300V NEC ITC PLTC CEC [CMG] 2/18 AWG Blue/Brn 6.5 Ohms PE 18 AWG Green/Yellow PVC Blue 7.9mm (.310 in) Foil 20 AWG RB50783-*M 1 492A 105 C 300V NEC ITC PLTC/CM CEC[CMG HLBCD] 2/18 AWG Blue/Brn 6.5 Ohms PE 18 AWG Green/Yellow Armor/PVC Yellow 12.7mm (0.5 in) Foil 18 AWG RB50874-*M BA 105 C 300V NEC ITC PLTC/CM CEC[CMG HLBCD] 2/18 AWG Blue/Brn 6.5 Ohms PE 18 AWG Green/Yellow Armor/PVC Blue 12.7mm (0.5 in) Foil 18 AWG RB50803-*M C 300V NEC ITC PLTC CEC [CMG] 2/18 AWG Blue/Brn 6.5 Ohms PE ne PVC Yellow 7.9mm (.310 in) Foil/Braid 20 AWG RB50784-*M 1 493B 105 C 300V NEC ITC PLTC CEC [CMG] 2/18 AWG Blue/Brn 6.5 Ohms PE ne PVC Blue 7.9mm (.310 in) Foil/Braid 20 AWG RB50786-*M 1 493O 105 C 300V NEC ITC PLTC CEC [CMG] 2/18 AWG Blue/Brn 6.5 Ohms PE ne PVC Orange 7.9mm (.310 in.) Foil/TC Braid 20 AWG RB50785-*M C 300V NEC ITC PLTC CEC [CMG] 2/16 AWG Blue/Brn 4.3 Ohms PE ne PVC Yellow 8.5mm (.335 in.) Foil 20 AWG RB50891-*M Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

19 FOUNDA OUNDATION TION fieldbus - Cable and Cordsets Try Cordset Builder Online! minifast eurofast Pin (Male) Socket (Female) Pin (Male) RSV WSV RKV WKV RSCV Bare RSV 49 x -*M WSV 49 x -*M RKV 49 x -*M WKV 49 x -*M RSCV 49 x -*M minifast eurofast Socket (Female) Pin (Male) Socket (Female) Pin (Male) RSV WSV RKV WKV RSCV WSCV RKCV WKCV RSV RSV 49 x -*M Indicates cable type. * Indicates length in meters. Consult factory for availability of armorfast with eurofast connectors. armorfast cable only - straight only. For nickel-plated brass coupling nut: RSV...to RSM... RSCV...to RSC... Bulk cable, see page 8 for standard lengths. Example RSV WSV 49 x -*M RSV RKV 49 x -*M RSV WKV 49 x -*M RSV RSCV 49 x -*M WSV WSV 49 x -*M WSV RKV 49 x -*M WSV WKV 49 x -*M WSV RSCV 49 x -*M RKV RKV 49 x -*M RKV WKV 49 x -*M RKV RSCV 49 x -*M WKV WKV 49 x -*M WSV RSCV 490-1M 1 METER WKV RSCV 49 x -*M RSCV RSCV 49 x -*M Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

20 FOUNDA OUNDATION TION fieldbus - Cable and Cordsets eurofast minifast eurofast bulkhead Pin (Male) Socket (Female) Pin (Male) Socket (Female) Pin (Male) Socket (Female) 2 WSCV RKCV WKCV RSFPV RKFPV FSFDV FKFDV WSCV 49 x -*M RKCV 49 x -*M WKCV 49 x -*M RSFPV 49 x -*M RKFPV 49 x -*M FSFDV 49 x -*M FKFDV 49 x -*M RSV WSCV 49 x -*M RSV RKCV 49 x -*M RSV WKCV 49 x -*M RSV RSFPV 49 x -*M RSV RKFPV 49 x -*M RSV FSFDV 49 x -*M RSV FKFDV 49 x -*M WSV WSCV 49 x -*M WSV RKCV 49 x -*M WSV WKCV 49 x -*M WSV RSFPV 49 x -*M WSV RKFPV 49 x -*M WSV FSFDV 49 x -*M WSV FKFDV 49 x -*M RKV WSCV 49 x -*M RKV RKCV 49 x -*M RKV WKCV 49 x -*M RKV RSFPV 49 x -*M RKV RKFPV 49 x -*M RKV FSFDV 49 x -*M RKV FKFDV 49 x -*M WKV WSCV 49 x -*M WKV RKCV 49 x -*M WKV WKCV 49 x -*M WKV RSFPV 49 x -*M WKV RKFPV 49 x -*M WKV FSFDV 49 x -*M WKV FKFDV 49 x -*M RSCV WSCV 49 x -*M RSCV RKCV 49 x -*M RSCV WKCV 49 x -*M RSCV RSFPV 49 x -*M RSCV RKFPV 49 x -*M RSCV FSFDV 49 x -*M RSCV FKFDV 49 x -*M WSCV WSCV 49 x -*M WSCV RKCV 49 x -*M WSCV WKCV 49 x -*M WSCV RSFPV 49 x -*M WSCV RKFPV 49 x -*M WSCV FSFDV 49 x -*M WSCV FKFDV 49 x -*M RKCV RKCV 49 x -*M RKCV WKCV 49 x -*M RKCV RSFPV 49 x -*M RKCV RKFPV 49 x -*M RKCV FSFDV 49 x -*M RKCV FKFDV 49 x -*M WKCV WKCV 49 x -*M WKCV RSFPV 49 x -*M WKCV RKFPV 49 x -*M WKCV FSFDV 49 x -*M WKCV FKFDV 49 x -*M 3000 Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

21 minifast Cordset and Receptacle Connector Dimensions and Pinouts RSV-* RKV-* WSV-* -* WKV-* RSFPV-* -* RKFPV-* -* Mounting Installation Male 1. Blue (-Voltage) 2. Brown (+ Voltage) 3. Bare (Shield Drain Wire) 4. Green/Yellow (Ground) Female Pinouts according to CENELEC EN numbering convention. Bracket dimensions are in [inches] Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

22 eurofast Cordset and Receptacle Connector Dimensions and Pinouts RSCV-* RKCV-* 2 WSCV-* -* WKCV-* FSFDV-* -* FKFDV-* -* Mounting Installation Male Female 1. Blue (-Voltage) 2. Brown (+ Voltage) 3. Bare (Shield Drain Wire) 4. Green/Yellow (Ground) 3000 Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

23 Marine Cable - Specifications InterlinkBT offers a full line of connectors approved by DNV and ABS. New FOUNDATION fieldbus cables that are UL1309 and CSA approved. Highly flame retardant, IEEE 1202/FT4 and IEC Category A Meets cold bend at -55 C (-67 F) Meets cold impact at -50 C (-58 F) Excellent moisture and oil resistance Excellent cut through and abrasion resistance Sunlight resistant Type 4910 UL1309 Approvals IEEE 1202/FT4 IEEE IEEE x 90 AWG Color Code 2/18 AWG Blue/Brn Data Pair DCR (/1000 ft) Insulation 6.5 Ohms XL PE Device Ground AWG Color Code 18 AWG Green/Yellow Outer Jacket Material Color minal O.D. TPE / Black 8.9mm (.350 in) Shield/Armor Type Drain Wire Foil 20 AWG Bulk Cable Part. RB51047-*M 4911 UL1309 IEEE 1202/FT4 IEEE IEEE x 90 2/18 AWG Blue/Brn 6.5 Ohms XL PE 18 AWG Green/Yellow TPE / Black 12.7mm (.500 in) TC Braid 20 AWG RB51048-*M Drilling Muds Water Based Synthetic Based Diesel Based Mineral Oil Based extremelife-130 cables have been extensively tested in various drilling muds/fluids. The extremelife-130 cables, with their exclusive arcticlife jacket materials, were compared with the industry standard neoprene cables. All tested cables passed the tensile strength and elogation tests. The extremelife-130 cables proved to be much more stable in size through the tests when compared to the neoprene jacketed cables Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

24 eurofast Heavy Duty Cordsets To meet the needs of the most demanding applications, use the heavy duty cordset. The long, heavy coupling nut completely supports the molded plug body to provide superior strength. 2 Extensive field and lab testing of the RKG style exceed SAE H requirements - right angle pull force tested to over 200 lbs! RSGV-* -* RKGV-* -* * For nickel-plated brass coupling nut RSGV... to RSG... RKGV... to RKG... Male 1. Blue (-Voltage) 2. Brown (+ Voltage) 3. Bare (Shield Drain Wire) 4. Green/Yellow (Ground) Female 3000 Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

25 Short Circuit minifast Junction Tee SC models only Description The FOUNDATION fieldbus junction tee is available with short circuit protection and is FM approved for Cl 1, Div 2 hazardous locations. Mechanically rugged, the new overmolded design provides unparalleled corrosive resistance. JTBS-49SC-M633 4-Pin Male P1 4-Pin Female S0-S6 Dimensions MOUNTING SCREW 1/4 (2) NOT INCLUDED Short Circuit Protection (only available with SC models) Electrical Short Circuit Protection: 55mA (Isc) Voltage Open Circuit: 35VDC Current Consumption: 5mA Specifications Diagnostic LED Indication: Green LED - Bus Power; P1 and S0 only Red LED - Short Circuit Indication Cl 1, Div 2; Groups A-D see drawing N T6, Ta = 70 C Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

26 Quick Selection Guide Part Number Number of Ports Connector Size Overmold Material Connector Material Short Circuit Protected 2 JTBS-49-M433 4 mini polyurethane stainless steel JTBS-49-M434 4 mini polyurethane nickel-plated brass JTBS-49-M633 6 mini polyurethane stainless steel JTBS-49-M634 6 mini polyurethane nickel-plated brass JTBS-49SC-M433 4 mini polyurethane stainless steel Yes JTBS-49SC-M434 4 mini polyurethane nickel-plated brass Yes JTBS-49SC-M633 6 mini polyurethane stainless steel Yes JTBS-49SC-M634 6 mini polyurethane nickel-plated brass Yes JTBS-49-E433 4 euro polyurethane stainless steel JTBS-49-E434 4 euro polyurethane nickel-plated brass JTBS-49-E633 6 euro polyurethane stainless steel JTBS-49-E634 6 euro polyurethane nickel-plated brass JTBS-49SC-E433 4 euro polyurethane stainless steel Yes JTBS-49SC-E434 4 euro polyurethane nickel-plated brass Yes JTBS-49SC-E633 6 euro polyurethane stainless steel Yes JTBS-49SC-E634 6 euro polyurethane nickel-plated brass Yes JTBS-49SC-IE433 4 idc polyurethane stainless steel Yes JTBS-49SC-IM633 6 idc/mini polyurethane nickel-plated brass Yes JTBS-49SC-IE633 6 idc/euro polyurethane stainless steel Yes JTBS-49SC-IM433 4 idc/mini polyurethane nickel-plated brass Yes 3000 Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

27 Fieldwireable Junction Tee JTBS-49SC-I633 JTBS-49SC-IM633 JTBS-49SC-IE633 Description The FOUNDATION fieldbus fieldwireable junction tee is available with short circuit protection and is FM approved for Cl 1, Div 2 hazardous locations. Mechanically rugged, the new overmolded design provides unparalleled corrosive resistance. JTBS-49SC-I633 Dimensions MOUNTING SCREW 1/4 (2) NOT INCLUDED Electrical Short Circuit Protection: 55mA (Isc) Voltage Open Circuit: 35VDC Current Consumption: 5mA Specifications Diagnostic LED Indication: Green LED - Bus Power Red LED - Short Circuit Indication Pending Cl 1, Div 2; Groups A-D see drawing N T6, Ta = 70 C Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

28 Field Wireable Junction Tee Assembly Consult factory for availability. 2 Description Includes termination kit for each port. 1. Trim cable jacket 15-20mm 2. Place nut and seal onto cable. Seal should rest on cable jacket 3. Insert conductors in carrier 4. Trim conductors flush 5. Insert keyed carrier into port 6. Tighten back nut Connector Assembly Carrier Seal Nut Termination kit Pinouts 1. Blue (-Voltage) 2. Brown (+ Voltage) 3. Bare (Shield Drain Wire) 4. Green/Yellow (Ground) Trim Length 15-20mm 3000 Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

29 minifast Passive Multiport Junctions (Bricks) SC models only Description The junction box is available with short circuit protection and is FM Approved for Cl 1, Div 2 hazardous locations. The rugged, fully encapsulated die-cast aluminum enclosure is available with stainless steel connectors. JBBS-49-M813 JBBS-49-M613 JBBS-49-M413* Dimensions / Part Number * JBBS-49SC-M413 overall dimensions 7.3mm X 2.52mm Short Circuit Protection (only available with SC models) Applications Electrical Short Circuit Protection: 55mA(Isc) Voltage Open Circuit: 35VDC Current Consumption: 5mA Diagnostic LED Indication: Green LED - Bus Power Red LED - Short Circuit Indication Cl 1, Div 2; Groups A-D see drawing N T6, Ta = 70 degrees C For nickel-plated brass receptacles change part number to -Mxx4. Example: JBBS-49-M413 to JBBS-49-M414 For fiberglass housing change part number to -Mx2x. Example: JBBS-49-M613 to JBBS-49-M Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

30 Quick Selection Guide Part Number Number of Ports Connector Size Housing Material Connector Material Short Circuit Protected 2 JBBS-49-M813 8 mini aluminum stainless steel JBBS-49-M613 6 mini aluminum stainless steel JBBS-49-M413 4 mini aluminum stainless steel JBBS-49-M814 8 mini aluminum nickel-plated brass JBBS-49-M614 6 mini aluminum nickel-plated brass JBBS-49-M414 4 mini aluminum nickel-plated brass JBBS-49-M823 8 mini fiberglass stainless steel JBBS-49-M623 6 mini fiberglass stainless steel JBBS-49-M423 4 mini fiberglass stainless steel JBBS-49-M824 8 mini fiberglass nickel-plated brass JBBS-49-M624 6 mini fiberglass nickel-plated brass JBBS-49-M424 4 mini fiberglass nickel-plated brass JBBS-49SC-M813 8 mini aluminum stainless steel Yes JBBS-49SC-M613 6 mini aluminum stainless steel Yes JBBS-49SC-M413 4 mini aluminum stainless steel Yes 3000 Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

31 eurofast Passive Multiport Junctions (Bricks) SC models only Description Rugged, fully encapsulated die-cast aluminum brick with eurofast connectors. JBBS-49-E813 JBBS-49-E613 JBBS-49-E413* Dimensions / Part Number * JBBS-49SC-E413 overall dimensions 7.3mm X 2.52mm Short Circuit Protection (only available with SC models) Applications Electrical Short Circuit Protection: 55mA(Isc) Voltage Open Circuit: 35VDC Current Consumption: 5mA Diagnostic LED Indication: Green LED - Bus Power Red LED - Short Circuit Indication Cl 1, Div 2; Groups A-D see drawing N T6, Ta = 70 degrees C For nickel-plated brass receptacles change part number to -Exx4. Example: JBBS-49-E413 to JBBS-49-E414 For fiberglass housing change part number to -Ex2x. Example: JBBS-49-E613 to JBBS-49-E Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

32 Quick Selection Guide Part Number Number of Ports JBBS-49-E813 8 Connector Size euro Housing Material aluminum Connector Material stainless steel Short Circuit Protected 2 JBBS-49-E613 6 euro aluminum stainless steel JBBS-49-E413 4 euro aluminum stainless steel JBBS-49-E814 8 euro aluminum nickel-plated brass JBBS-49-E614 6 euro aluminum nickel-plated brass JBBS-49-E414 4 euro aluminum nickel-plated brass JBBS-49-E823 8 euro fiberglass stainless steel JBBS-49-E623 6 euro fiberglass stainless steel JBBS-49-E423 4 euro fiberglass stainless steel JBBS-49-E824 8 euro fiberglass nickel-plated brass JBBS-49-E624 6 euro fiberglass nickel-plated brass JBBS-49-E424 4 euro fiberglass nickel-plated brass JBBS-49SC-E813 8 euro aluminum stainless steel JBBS-49SC-E613 6 euro aluminum stainless steel JBBS-49SC-E413 4 euro aluminum stainless steel 3000 Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

33 Device Gland Receptacles - 3 wire Selection Guide eurofast minifast 1/2 - NPT FSV 49-*M / 14.5 RSFV 49-*M / /4 - NPT FSV 49-*M / RSFV 49-*M / M20 FSV 49-*M / M20 RSFV 49-*M / M20 * For female receptacles change part number to (FKV, RKFV...). FSV 49-*M / 14.5 RSFV 49-*M / 14.5 FSV 49-*M / RSFV 49-*M / FSV 49-*M / M20 RSFV 49-*M / M20 minifast 1. Blue (-Voltage) 2. Brown (+ Voltage) 3. N/C 4. Green/Yellow (Ground) eurofast Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

34 Device Gland Receptacles - 2 wire Selection Guide eurofast minifast 1/2 - NPT FSV 49T-*M / 14.5 RSFV 49T-*M / /4 - NPT FSV 49T-*M / RSFV 49T-*M / FSV 49T-*M / 14.5 M20 FSV 49T-*M / M20 * Indicates length in meters. For female receptacles change part number to (FKV, RKFV...). RSFV 49T-*M / 14.5 RSFV 49T-*M / M20 2 FSV 49T-*M / RSFV 49T-*M / FSV 49T-*M / M20 RSFV 49T-*M / M20 minifast 1. Blue (-Voltage) 2. Brown (+Voltage) 3. N/C 4. N/C eurofast 3000 Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

35 Terminating Resistors Terminate at the beginning and end of each segment. minifast Terminating Resistor internal resistor and capacitor male connector 1µF 100Ω RSV 49-TR eurofast Terminating Resistor internal resistor and capacitor male connector 1µF 100Ω RSEV 49-TR For nickel-plated brass change: RSEV 49-TR to RSE 49-TR RSV 49-TR to RSM 49-TR Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

36 Conduit Adapter minifast eurofast Schematic 1-port 2-port BCA 49-M223 BCA 49-M123 BCA 49-E223 BCA 49-E123 trunk drop drop trunk drop Change part number from BCA 49-M223 to BCA 49/P- M223 to fit on PVC coated conduit adapter. 2 Description The conduit adapter attaches to a standard conduit body for transition to minifast or eurofast connectors. Gasket and mounting hardware included (8-32 x 1/2 ) Pinout Dimensions 1. Blue (-Voltage) 2. Brown (+ Voltage) 3. Bare (Shield Drain Wire) 4. Green/Yellow (Ground) CROUSE - HINDS Hub Size = 3/4 Shape Style Part Number C Form 8 Mark 9 C28 C29 Conduit Bodies LB Form 8 Mark 9 LB28 LB29 LL Form 8 Mark 9 LL28 LL29 LR Form 8 Mark 9 LR28 LR29 Conduit connectors for use with armorfast cable O-Z Gedney JMC /2NPT 3000 Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

37 FOUNDA OUNDATION TION TION fieldbus Tees Part Number RSV 2RKV 49 Dimensions Description minifast tee data, ground, shield stainless steel coupling nuts RSV FKV RKV 49 minifast to eurofast drop data, ground, shield stainless steel coupling nuts For nickel-plated brass coupling nuts: Change part number (RSV 2RKV... RSM 2RKM...) For nickel-plated brass coupling nuts: Change part number (RSCV 2RKCV... RSC 2RKC...) Part Number RSCV 2RKCV 49 Dimensions Description eurofast tee stainless steel coupling nuts Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

38 Field Wireable Tee Description The Field Wireable Tee is a hybrid connection offering system-wide plug-and-play convenience. This allows an extremely rapid changeover to a connectorized network, often in less than 15 minutes. The Field Wireable IP67 Tee SPTTM13-A49 features standardized minifast connectors for the drop connection and field wireable terminals on the trunk connections. This provides the best of both worlds, reliable connections on the short lengths and ease of installation planning on the long trunk runs. 2 SPTT1-A49 SPTTM13-A49 Dimensions Wir ire Table Specifications Pin Designation Color 1 V - Blue 2 V + Brown 3 Shield Bare 4 Ground Green/Yellow 3000 Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

39 Gender Changers and Elbow Connectors Part Number RSV RSV 49 Dimensions Description minifast Male Gender Changer female cordset to male receptacle RKV RKV 49 minifast Female Gender Changer male cordset to female receptacle WSV RKV 49 minifast Elbow right angle male to female connector RSM 49-FK 4.5* minifast to eurofast Adapter minifast male to eurofast female connector nickel-plated brass housing For nickel-plated brass coupling nuts: Change part number (RSV RSV...RSM RSM...) * = Consult factory for availability Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

40 Surge Suppressor Description This surge suppressor protects the data communication lines (V+ and V-) rather than just the shield. The unique multi-stage design provides superior surge protection. The surge suppressor absorbs the front end of the transient, responding in less than a nanosecond, then diverts the surge energy to ground. Once the surge has been dissipated the suppressor automatically resets and waits for the next surge. The minifast connectors provide IEC IP67 protection in the rugged polyurethane overmolded body. The surge suppressor is available with stainless steel coupling nuts and a ground stud. RSV RKV 49 SS 2 Dimensions Specifications Electrical Maximum Operating Voltage: 27 Volts Maximum Operating Current: 200mA Clamping Action Turn-On: 28.5 Volts Maximum Clamping at 2 ka: (8 X 20 µsec): 44 Volts Maximum Surge Voltage: 20 kv Maximum Surge Current: 2.5kA Current Leakage/Line At Operating Voltage: 5µA Capacitance/Line At Operating Voltage: 500pF Response Time: Less than 1 nanosecond Mechanical Ground Stud: Stainless Steel Operating Temperature: -40 C to +85 C 3000 Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

41 Power Supply Conditioner Description The Power Supply Conditioner meets the needs of redundant power supplies for FOUNDATION fieldbus. This product has primary and secondary power inputs to supply two Fieldbus H1 segments. Standard 24VDC power feeds into supplies A and B. It also takes care of filtering the fieldbus signal from the power source. LED s indicate which Power Supply is primary and secondary. Diagnostics provide the status of each power supply, indicating either READY or ACTIVE. The status is also provided through relay outputs for further monitoring. Internal switches turn on/off terminators per segment. BRPC-49-M213 4-Pin Euro = Monitor Dimensions 5-Pin Mini = Supply A & B 4-Pin Mini = Segment 1 & 2 Specifications Electrical Supply Voltage (Supply A & B): VDC Supply Surge Protection (Supply A & B): >36 VDC Supply Redundancy (Supply A & B): Supply A is Primary. If Supply A Voltage drops below 11 V, Supply B becomes Active Supply A becomes Active once Voltage >11V Output Voltage (Segment 1 & 2): Input Voltage - 3 Volts Output Current (Segment 1 & 2): <1A Short Circuit Protection (Segment 1 & 2): >1A to Infinite Diagnostic Power LED Indications: Green - Active / Red - Power Segment LED Indications: Green - Active Supply Monitor Contacts (Supply A & B): Solid State, AC/DC <400 V, <70 ma when supply Voltage >11V, Contact Is Closed Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

42 Lokfast Guard minifast eurofast Standard SHLD, MINI SHLD, EURO Field Wireable SHLD, MINI FW SHLD, EURO FW SHLD, MINI (10/bag) 2 Description The JTBS-49SC series short circuit brick is classified as nonincendive equipment. This means that it is considered nonarcing under normal operating conditions. In a fieldbus system the trunk does not need to be serviced under normal operating conditions. The trunk connections (P1 and S0) are to be locked with a Lokfast Guard to mechanically prevent separation. Assembly/ Disassembly Specifications Mechanical Dimensions: 43mm X D/A X 39mm Material: Nylon 6 Environmental: Sun Resistant, UV Stable Operating Temperature: -30ºC to 100ºC Flammability: UL94 (5=V-0; 4=V-1; 3=V-2; 1=HB) 3000 Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

43 Bulkhead Feed-Thru Receptacles panel mount minifast Bulkhead Receptacle straight male/female feed thru RSFV RKF 49/22 eurofast Bulkhead Receptacle straight male/female feed thru FKV FSV 49/M12 For nickel-plated brass coupling nuts change part number to: RSFV RKFV 49/22 to RSF RKF 49/22 or FKV FSV 49/M12 to FKM FS 49/M Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

44 Panel Mount Receptacles - minifast, eurofast Selection Guide Female Male Leads minifast eurofast RKFV 49 - *M RSFV 49 - *M FKV 49 - *M FSV 49 - *M Cable minifast eurofast * Indicates length in meters. RKFV *M RSFV *M FKV *M FSV *M 2 RKFV 49 RSFV 49 FKV 49 FSV 49 Part numbers on diagrams represent solder cups only. Female 1. Blue (-Voltage) 2. Brown (+ Voltage) 3. Bare (Shield Drain Wire) 4. Green/Yellow (Ground) eurofast 3000 Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

45 Field Wireable Connectors - minifast Selection Guide Aluminum x Stainless Steel x Female B /9 BV /9 Male BS /9 BSV /9 Accepts 6-8 mm (0.236 to ) cable x - coupling nut material housing material - nylon B /9 BS /9 BV /9 BSV /9 Male 1. Blue (-Voltage) 2. Brown (+ Voltage) 3. Bare (Shield Drain Wire) 4. Green/Yellow (Ground) Female Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

46 Field Wireable Connectors - eurofast Selection Guide Straight Right Angle Female B8141-0/PG9 B8241-0/PG9 Male BS8141-0/PG9 BS8241-0/PG9 Accepts 4-8 mm (0.157 to ) cable 2 B8141-0/PG9 B8241-0/PG9 BS8141-0/PG9 BS8241-0/PG9 Female eurofast Rating: 3 A, 36 VDC 1. Blue (-Voltage) 2. Brown (+ Voltage) 3. Bare (Shield Drain Wire) 4. Green/Yellow (Ground) Male eurofast Rating: 3 A, 36 VDC 3000 Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

47 Closure Caps Closure caps are for unused ports on the junction box. Dimensions RKMV BC Description minifast closure cap mates to male receptacles Stainless steel IP67 rated RSMV BC minifast closure cap mates to female receptacles Stainless steel IP67 rated RSFK-BC (10/BAG) minifast Closure Cap mates to female receptacles nylon VZ-3 (8/BAG) eurofast Closure Cap mates to female receptacles nylon Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

48 PROFIBUS -PA Cables and Accessories Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

49 PROFIBUS -PA PROFIBUS -PA (Process Automation) uses synchronous transfer mode technology, as defined in IEC , to communicate between field devices and the RS 485 backbone of PROFIBUS -DP. A segment coupler, or gateway is installed to bridge PROFIBUS -DP with PROFIBUS -PA. Otherwise, the protocols are identical, allowing transparent communication between general purpose automation systems and decentralized field devices. PROFIBUS -PA is a master-slave bus. Transmitters used in the process industry are typically slave devices or passive stations which only communicate at the request of the master. General Layout Topologies The topology for PROFIBUS -DP is a linear bus. Branching can be accomplished with repeaters or, in the case of PROFIBUS -PA, this can be accomplished with the segment couplers. The PROFIBUS -PA topology follows the physical layer as defined in ISA SP daisy chain or star topologies are allowed Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

50 Star Topology Method A star topology has a central connection point to all terminations. This layout works well when there are many devices in a localized area. For instance, the control room may be located about 300 meters away from a cracker tower. This tower may have five or six temperature transmitters. All of these devices need to be connected to the fieldbus segment. The best design would be to connect them all to a junction brick and then run a Home Run cable from the junction brick back to the control room. See Figure 4 for a pictorial example. The Home Run cable is considered the main trunk line of communication. Each device that is connected to the junction brick is called a spur. In other industrial networks spurs are called drops off the trunk line. Figure 4 - Star Topology Example 3 Daisy Chain Configuration Another layout design is to daisy chain all the devices. Each device would require a tee so that the Home Run cable would be able to go to each device. From a design standpoint, the Daisy Chain method is easiest to do when the exact cable tracks are known. Pre-made cordsets can then be purchased and the network is easy to assemble. See Figure e 5 for an example drawing. A fieldbus transmitter is connected to each of the tanks in the field. The Home Run cable essentially is routed to each device in series. Figure 5 - Daisy Chain Layout Transmitters In many fieldbus installations it makes sense to mix both Star and Daisy Chain topology layouts. Remember that one of the benefits to fieldbus is reduced wiring of devices, leading to faster start-up times Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

51 Fieldbus Cable Specifications The specifications for PROFIBUS -PA physical media are defined by IEC and the ISA-S50.02 Part 2 Physical Layer Standards. There are essentially four types of cable designations for fieldbus. Type A cable is the most preferred for new installations because it allows for the most versatile lengths. The other types of cable are for installations where cable already exists from 4-20 ma systems. See Table 1. Type Cable Description Conductor Size Maximum Length Type A Shielded, Twisted Pair # 18 Awg 1900 m (6232 ft) Type B Shielded, Multi Twisted Pair # 22 Awg 1200 m (3936 ft) Type C Unshielded, Multi Twisted Pair # 26 Awg 400 m (1312 ft) Type D Shielded, Untwisted Pair # 16 Awg 200 m (656 ft) Table 1 Fieldbus Cable Specifications offers cables with both two conductors and three conductors, with the third conductor available for a centralized ground of devices if needed. cables meet or exceed the specifications of ANSI/ISA-SP , the fieldbus standard for use in industrial control systems. The maximum spur length is determined by the number of devices in the segment. Cable Trunk Number of Devices Maximum Spur Length 0 m (0 ft) 30 m (98 ft) 1900 m m (197 ft) 90 m (295 ft) 120 m (394 ft) Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

52 PROFIBUS -PA - Cable Specifications Our cable meets requirements of ISA/SP50 and PROFIBUS -PA Type A cable. All cables are rated -40ºC to 105ºC and are sunlight resistant. Available in 3-wire versions with a device ground or 2-wire versions. 1 Cable Specifications Type A Cable - Designed for harsh environments - Temperature range of -40 to 105 C (-40 to +221F) 11 - Governed by: ISA SP50.02 specification - Sunlight resistant per test - PLTC and ITC rated (CSA FT4) - Impedence[Z 0 at f r (31.25 khz)] = 100Ω ± 20% - Maximum attenuation at 1.25 f r (39 khz) = 3.0 db/km - Maximum capacitive unbalance to shield = 2 nf/km - Maximum DC resistance (per conductor) = 24 Ω/km - Maximum propagation delay variance f r to 1.25 f r = 1.7 µs/km - Conductor cross-sectional area (wire size) = nominal 0.8 mm 2 (#18 AWG) - Minimum shield coverage shall be 90% 33 Data Pair Device Ground Outer Jacket Shield Type Approvals AWG Color Code DCR (/1000 ft) Insulation AWG Color Code Material Color minal O.D. Type Drain Wire Bulk Cable Part. Ref C 300V N EC ITC PLTC C EC [CMG] 2/18 AWG Blue/Brn 6.5 Ohms PE ne PVC Orange 7.9mm (.310 in.) Foil/Braid 20 AWG RB50785-*M B 105 C 300V N EC ITC PLTC C EC [CMG] 2/18 AWG Blue/Brn 6.5 Ohms PE ne PVC Blue 7.9mm (.310 in.) Foil/Braid 20 AWG RB50786-*M A 105 C 300V N EC ITC PLTC/CM C EC [CMG HLBCD] 2/18 AWG Blue/Brn 6.5 Ohms PE 18 AWG Green/Yellow Armor/PVC Orange 12.7mm (0.5 in.) Foil 18 AWG RB50929-*M B 82BA 105 C 300V N EC ITC PLTC C EC [CMG] 2/18 AWG Blue/Brn 6.5 Ohms PE 18 AWG Green/Yellow Armor/PVC Blue 12.7mm (0.5 in.) Foil 18 AWG RB50952-*M B 83BK 105 C 300V N EC ITC PLTC C EC [CMG] 2/18 AWG Blue/Brn 6.5 Ohms PE ne PVC Black 7.9mm (.310 in.) Foil/Braid 20 AWG RB50860-*M Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

53 PROFIBUS -PA - Cables and Cor ordsets Try Cordset Builder Online! minifast eurofast Pin (Male) Socket (Female) Pin (Male) RSV WSV RKV WKV RSCV Bare RSV 48 x - *M WSV 48 x -*M RKV 48 x -*M WKV 48 x -*M RSCV 48 x -*M minifast eurofast Socket (Female) Pin (Male) Socket (Female) Pin (Male) RSV WSV RKV WKV RSCV WSCV RKCV WKCV RSV RSV 48 x -*M Indicates cable type * Indicates length in meters Consult factory for availability of armorfast with eurofast connectors. armorfast cable only For nickel-plated brass coupling nut: RSV...to RSM... RSCV...to RSC... Bulk cable, see page 8 for standard lengths RSV WSV 48 x -*M RSV RKV 48 x -*M RSV WKV 48 x -*M WSV WSV 48 x -*M WSV RKV 48 x -*M WSV WKV 48 x -*M RKV RKV 48 x -*M RKV WKV 48 x -*M WKV WKV 48 x -*M RSV RSCV 48 x -*M WSV RSCV 48 x -*M RKV RSCV 48 x -*M WKV RSCV 48 x -*M RSCV RSCV 48 x -*M WSV RSCV 482-*M Example 1 METER Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

54 PROFIBUS -PA - Cables and Cor ordsets eurofast minifast bulkhead eurofast bulkhead Pin (Male) Socket (Female) Pin (Male) Socket (Female) Pin (Male) Socket (Female) WSCV RKCV WKCV RSFPV RKFPV FSFDV FKFDV WSCV 48 x -*M RKCV 48 x -*M WKCV 48 x -*M RSFPV 48 x -*M RKFPV 48 x -*M FSFDV 48 x -*M FKFDV 48 x -*M RSV WSCV 48 x -*M RSV RKCV 48 x -*M RSV WKCV 48 x -*M RSV RSFPV 48 x -*M RSV RKFPV 48 x -*M RSV FSFDV 48 x -*M RSV FKFDV 48 x -*M WSV WSCV 48 x -*M WSV RKCV 48 x -*M WSV WKCV 48 x -*M WSV RSFPV 48 x -*M WSV RKFPV 48 x -*M WSV FSFDV 48 x -*M WSV FKFDV 48 x -*M RKV WSCV 48 x -*M RKV RKCV 48 x -*M RKV WKCV 48 x -*M RKV RSFPV 48 x -*M RKV RKFPV 48 x -*M RKV FSFDV 48 x -*M RKV FKFDV 48 x -*M 3 WKV WSCV 48 x -*M WKV RKCV 48 x -*M WKV WKCV 48 x -*M WKV RSFPV 48 x -*M WKV RKFPV 48 x -*M WKV FSFDV 48 x -*M WKV FKFDV 48 x -*M RSCV WSCV 48 x -*M RSCV RKCV 48 x -*M RSCV WKCV 48 x -*M RSCV RSFPV 48 x -*M RSCV RKFPV 48 x -*M RSCV FSFDV 48 x -*M RSCV FKFDV 48 x -*M WSCV WSCV 48 x -*M WSCV RKCV 48 x -*M WSCV WKCV 48 x -*M WSCV RSFPV 48 x -*M WSCV RKFPV 48 x -*M WSCV FSFDV 48 x -*M WSCV FKFDV 48 x -*M RKCV RKCV 48 x -*M RKCV WKCV 48 x -*M RKCV RSFPV 48 x -*M RKCV RKFPV 48 x -*M RKCV FSFDV 48 x -*M RKCV FKFDV 48 x -*M WKCV WKCV 48 x -*M WKCV RSFPV 48 x -*M WKCV RKFPV 48 x -*M WKCV FSFDV 48 x -*M WKCV FKFDV 48 x -*M 3000 Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

55 minifast Cor ordset and Receptacle Connector Dimensions and Pinouts RSV-* RKV-* WSV-* -* WKV-* RSFPV-* -* RKFPV-* -* Mounting Installation Male 1. Brown (+ Voltage) 2. N/C 3. Blue (- Voltage) 4. Bare (Shield Drain Wire) Female Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

56 eurofast Cor ordset and Receptacle Connector Dimensions and Pinouts RSCV-* RKCV-* WSCV-* -* WKCV-* -* 3 FSFDV-* -* FKFDV-* -* Mounting Installation Male Female 1. Brown (+ Voltage) 2. N/C 3. Blue (- Voltage) 4. Bare (Shield Drain Wire) 3000 Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

57 Short Circuit minifast Junction Tee SC models only Description The PROFIBUS -PA junction tee is available with short circuit protection. Mechanically rugged, the new overmolded design provides unparalleled corrosive resistance. JTBS-48SC-M633 4-Pin Male P1 4-Pin Female Dimensions S0-S6 MOUNTING SCREW 1/4 (2) NOT INCLUDED Short Circuit Protection (only available with SC models) Specifications Electrical Short Circuit Protection: 55mA(Isc) Voltage Open Circuit: 35VDC Current Consumption: 5mA Diagnostic LED Indication: Green LED - Bus Power Red LED - Short Circuit Indication Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

58 Quick Selection Guide Part Number Number of ports Connector size Overmold material Connector material Short Circuit Protected JTBS-48-M433 4 mini polyurethane stainless steel JTBS-48-M434 4 mini polyurethane nickel-plated brass JTBS-48-M633 6 mini polyurethane stainless steel JTBS-48-M634 6 mini polyurethane nickel-plated brass JTBS-48SC-M433 4 mini JTBS-48SC-M434 4 mini polyurethane polyurethane stainless steel nickel-plated brass Yes Yes 3 JTBS-48SC-M633 6 mini polyurethane stainless steel Yes JTBS-48SC-M634 6 mini polyurethane nickel-plated brass Yes JTBS-48-E433 4 euro polyurethane stainless steel JTBS-48-E434 4 euro polyurethane nickel-plated brass JTBS-48-E633 6 euro polyurethane stainless steel JTBS-48-E634 6 euro polyurethane nickel-plated brass JTBS-48SC-E433 4 euro polyurethane stainless steel Yes JTBS-48SC-E434 4 euro polyurethane nickel-plated brass Yes JTBS-48SC-E633 6 euro polyurethane stainless steel Yes JTBS-48SC-E634 6 euro polyurethane nickel-plated brass Yes 3000 Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

59 minifast Passive Multiport Junctions (Bricks) SC models only Description Keyed for PROFIBUS -PA Systems Rugged, fully encapsulated die-cast aluminum enclosures Bus-In/Bus-Out eliminate need for splitter tee Provide common ground for all devices Stainless steel receptacles JBBS-48-M813 JBBS-48-M613 JBBS-48-M413 Dimensions / Part Number Short Circuit Protection (only available with SC models) Applications Electrical Short Circuit Protection: 55mA(Isc) Voltage Open Circuit: 35VDC Current Consumption: 5mA Diagnostic LED Indication: Green LED - Bus Power Red LED - Short Circuit Indication For nickel-plated brass receptacles change part number to -Mxx4. Example: JBBS-48-M413 to JBBS-48-M414 For fiberglass housing change part number to -Mx2x. Example: JBBS-48-M613 to JBBS-48-M Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

60 Quick Selection Guide Part Number Number of ports Connector size Housing material Connector material Short Circuit Protected JBBS-48-M813 8 mini aluminum stainless steel JBBS-48-M613 6 mini aluminum stainless steel JBBS-48-M413 4 mini aluminum stainless steel JBBS-48-M814 8 mini aluminum nickel-plated brass JBBS-48-M614 6 mini aluminum nickel-plated brass 3 JBBS-48-M414 4 mini aluminum nickel-plated brass JBBS-48-M823 8 mini fiberglass stainless steel JBBS-48-M623 6 mini fiberglass stainless steel JBBS-48-M423 4 mini fiberglass stainless steel JBBS-48-M824 8 mini fiberglass nickel-plated brass JBBS-48-M624 6 mini fiberglass nickel-plated brass JBBS-48-M424 4 mini fiberglass nickel-plated brass JBBS-48SC-M813 8 mini aluminum stainless steel Yes JBBS-48SC-M613 6 mini aluminum stainless steel Yes JBBS-48SC-M413 4 mini aluminum stainless steel Yes 3000 Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

61 eurofast Passive Multiport Junctions (Bricks) Description Keyed for PROFIBUS -PA Systems Rugged, fully encapsulated die-cast aluminum enclosures Bus-In/Bus-Out eliminate need for splitter tee Provide common ground for all devices Stainless steel receptacles JBBS-48-E813 JBBS-48-E613 JBBS-48-E413 Dimensions / Part Number Applications 8, 6, and 4-Port Junction Bricks bus-in / bus-out straight throughports spurs with eurofast connectors For nickel-plated brass receptacles change part number to -Exx4. Example: JBBS-48-E413 to JBBS-48-E414 For fiberglass housing change part number to -Ex2x. Example: JBBS-48-E613 to JBBS-48-E Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

62 Quick Selection Guide Part Number Number of ports Connector size Housing material Connector material Short Circuit Protected JBBS-48-E813 8 euro aluminum stainless steel JBBS-48-E613 6 euro aluminum stainless steel JBBS-48-E413 4 euro aluminum stainless steel JBBS-48-E814 8 euro aluminum nickel-plated brass JBBS-48-E614 6 euro JBBS-48-E414 4 euro aluminum aluminum nickel-plated brass nickel-plated brass 3 JBBS-48-E823 8 euro fiberglass stainless steel JBBS-48-E623 6 euro fiberglass stainless steel JBBS-48-E423 4 euro fiberglass stainless steel JBBS-48-E824 8 euro fiberglass nickel-plated brass JBBS-48-E624 6 euro fiberglass nickel-plated brass JBBS-48-E424 4 euro fiberglass nickel-plated brass 3000 Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

63 Device Gland Receptacles - 2 wire Selection Guide eurofast minifast 1/2 - NPT FSV 48T-*M / 14.5 RSFV 48T-*M / /4 - NPT FSV 48T-*M / RSFV 48T-*M / M20 FSV 48T-*M / M20 RSFV 48T-*M / M20 * Indicates length in meters. For female receptacles change part number to (FKV, RKFV...). FSV 48T-*M / 14.5 RSFV 48T-*M / 14.5 FSV 48T-*M / RSFV 48T-*M / FSV 48T-*M / M20 RSFV 48T-*M / M20 minifast 1. Brown (+ Voltage) 2. N/C 3. Blue (- Voltage) 4. N/C eurofast Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

64 Terminating Resistors terminate at the beginning and end of each segment minifast Terminating Resistor internal resistor and capacitor male connector 1µF 100Ω 3 RSV 48-TR eurofast Terminating Resistor internal resistor and capacitor male connector 1µF 100Ω RSEV 48-TR For nickel-plated brass change: RSEV 48-TR to RSE 48-TR RSV 48-TR to RSM 48-TR 3000 Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

65 Terminating Resistors - Ex terminate at the beginning and end of each segment minifast Terminating Resistor internal resistor and capacitor male connector 1µF 100Ω RSV 48-TR-Ex eurofast Terminating Resistor internal resistor and capacitor male connector 1µF 100Ω RSEV 48-TR-Ex For nickel-plated brass change: RSEV 48-TR-Ex to RSE 48-TR-Ex RSV 48-TR-Ex to RSM 48-TR-Ex Ex Approval BVS 99.E.2044X Entity Parameters: Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free: U 0 : I 0 : P 0 : T a : 16.2V 500mA 1.8W -40ºC...+70ºC (EEx ia IIC T4) -40ºC...+70ºC (EEx ia IIC T6)

66 Conduit Adapter minifast eurofast Schematic 1-port 2-port BCA 48-M223 BCA 48-M123 BCA 48-E223 BCA 48-E123 trunk drop trunk drop drop Description The conduit adapter attaches to a standard conduit body for transition to minifast or eurofast connectors. Gasket and mounting hardware included (8-32 x 1/2 ) Pinout Dimensions 1. Brown (+ Voltage) 2. N/C 3. Blue (- Voltage) 4. Bare (Shield Drain Wire) 3 CROUSE - HINDS Hub Size = 3/4 Shape Style Part Number C Form 8 Mark 9 C28 C29 Conduit Bodies LB Form 8 Mark 9 LB28 LB29 LL Form 8 Mark 9 LL28 LL29 LR Form 8 Mark 9 LR28 LR29 Conduit connectors for use with armorfast cable O-Z Gedney JMC /2NPT 3000 Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

67 PROFIBUS -PA Tees Part Number RSV 2RKV 48 Dimensions Description minifast tee data, ground, shield stainless steel coupling nuts RSV FKV RKV 48 minifast to eurofast drop data, ground, shield stainless steel coupling nuts For nickel-plated brass coupling nuts: Change part number (RSV 2RKV... RSM 2RKM...) For nickel-plated brass coupling nuts: Change part number (RSCV 2RKCV... RSC 2RKC...) Part Number RSCV 2RKCV 48 Dimensions Description eurofast tee stainless steel coupling nuts Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

68 Field Wireable Tee Description The Field Wireable Tee is a hybrid connection offering system-wide plug-and-play convenience. This allows an extremely rapid changeover to a connectorized network, often in less than 15 minutes. The Field Wireable IP67 SPTTM13-A48 tee features standardized minifast connectors for the drop connection and field wireable terminals on the trunk connections. This provides the best of both worlds, reliable connections on the short lengths and ease of installation planning on the long trunk runs. SPTT1-A48 SPTTM13-A48 3 Dimensions Wir ire Table Specifications Pin 1 Designation PA+ Color Brown 2 N/C -- 3 PA- Blue 4 Shield Drain 3000 Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

69 Gender Changers and Elbow Connectors Part Number RSV RSV 48 Dimensions Description minifast Male Gender Changer female cordset to male receptacle RKV RKV 48 minifast Female Gender Changer male cordset to female receptacle WSV RKV 48 minifast Elbow right angle male to female connector RSM 48-FK 4.5* minifast to eurofast Adapter minifast male to eurofast female connector nickel-plated brass housing For nickel-plated brass coupling nuts: Change part number (RSV RSV...RSM RSM...) Consult factory for availability of stainless steel Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

70 Surge Suppressor Description This surge suppressor protects the data communication lines (V+ and V-) rather than just the shield. The unique multi-stage design provides superior surge protection. The surge suppressor absorbs the front end of the transient, responding in less than a nanosecond, then diverts the surge energy to ground. Once the surge has been dissipated the suppressor automatically resets and waits for the next surge. The minifast connectors provide IP67 protection in the rugged polyurethane overmolded body. The surge suppressor is available with stainless steel coupling nuts and ground stud. RSV RKV 48 SS 3 Dimensions Specifications Electrical Maximum Operating Voltage: 27 Volts Maximum Operating Current: 200mA Clamping Action Turn-On: 28.5 Volts Maximum Clamping at 2 ka: (8 X 20 µsec) : 44 Volts Maximum Surge Voltage: 20 kv Maximum Surge Current: 2.5kA Current Leakage/Line At Operating Voltage: 5µA Capacitance/Line At Operating Voltage: 500pF Response Time: Less than 1 nanosecond Mechanical Ground Stud: Stainless Steel Operating Voltage: 24 Volts Operating Temperature: -40 C to +85 C 3000 Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

71 Lokfast Guard minifast eurofast Standard SHLD, MINI SHLD, EURO Field Wireable SHLD, MINI FW SHLD, EURO FW SHLD, MINI (10/bag) Description The JTBS-48SC series short circuit brick is classified as nonincendive equipment. This means that it is considered nonarcing under normal operating conditions. In a fieldbus system the trunk does not need to be serviced under normal operating conditions. The trunk connections (P1 and S0) are to be locked with a Lokfast Guard to mechanically prevent separation. Assembly/ Disassembly Specifications Mechanical Dimensions: 43mm X D/A X 39mm Material: Nylon 6 Environmental: Sun Resistant, UV Stable Operating Temperature: -30ºC to 100ºC Flammability: UL94 (5=V-0; 4=V-1; 3=V-2; 1=HB) Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

72 Bulkhead Feed-Thru Receptacles panel mount 3 minifast Bulkhead Receptacle straight male/female feed thru RSFV RKF 48/22 eurofast Bulkhead Receptacle straight male/female feed thru FKV FSV 48/M Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

73 Panel Mount Receptacles - minifast, eurofast Selection Guide Female Male leads minifast eurofast RKFV 48 - *M RSFV 48 - *M FKV 48 - *M FSV 48 - *M cable minifast eurofast RKFV *M RSFV *M FKV *M FSV *M RKFV 48 - *M RSFV 48 - *M FKV 48 - *M FSV 48 - *M Female 1. Brown (+ Voltage) 2. N/C 3. Blue (- Voltage) 4. Bare (Shield Drain Wire) eurofast Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

74 Field Wireable Connectors - minifast Selection Guide Aluminum x Stainless Steel x Female B /9 BV /9 Male BS /9 BSV /9 Accepts 6-8 mm (0.236 to ) cable x - coupling nut housing material - nylon B /9 BS /9 3 BV /9 BSV /9 Male 1. Brown (+ Voltage) 2. N/C 3. Blue (- Voltage) 4. Bare (Shield Drain Wire) Female 3000 Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

75 Field Wireable Connectors - eurofast Selection Guide Straight Right Angle Female B8141-0/PG9 B8241-0/PG9 Male BS8141-0/PG9 BS8241-0/PG9 Field wireable connectors for bus lines and drops facilitate field replacement. B8141-0/PG9 B8241-0/PG9 BS8141-0/PG9 BS8241-0/PG9 Female eurofast Rating: 3 A, 36 VDC 1. Brown (+ Voltage) 2. N/C 3. Blue (- Voltage) 4. Bare (Shield Drain Wire) Male eurofast Rating: 3 A, 36 VDC Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

76 Closure Caps Closure caps are for unused ports on the junction box. Dimensions RKMV BC Description minifast closure cap mates to male receptacles Stainless steel IP67 rated RSMV BC minifast closure cap mates to female receptacles Stainless steel IP67 rated 3 RSFK-BC (10/BAG) minifast Closure Cap mates to female receptacles nylon VZ-3 (8/BAG) eurofast Closure Cap mates to female receptacles nylon 3000 Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

77 HART Cables and Accessories Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

78 HART Overview HART (Highway Addressable Remote Transducer) is a protocol which supports two-way digital communication for process measurement and control devices. Although it is not an international standard, it is considered an open protocol, broadly accepted in the process industry. HART devices can store process related information and communicate digitally. It can also be used with traditional 4-20 ma devices. This is beneficial if there is a large existing installed base of 4-20 ma transmitters. HART is a master-slave protocol. This means that when the master calls out the slave s address, the slave responds. The master takes control of the time and operational sequence of the bus. There can be two masters, including a hand-held communicator. Up to 15 slave devices can be connected to one multidrop line (limitations exist for intrinsically safe areas). HART uses the Bell 202 standard frequency shift keying (FSK) for digital communication. The FSK signal is superimposed on the 4 to 20 ma analog measurement signal. The FSK signal does not cause interference with the analog measurement since the average value is zero. The frequency of 1200 hz is used for a logical 1 and 2200 hz is used for a logical 0. General Layout Topologies Field wiring of HART uses twisted pair cable, either screened as a pair in a cable or multiple screens and an overall screen on cable containing multiple pairs. There are two basic structures for wiring a system. The first is point-topoint wiring. This means that every pair that connects to an instrument is returned to the control, completely isolated from the other pairs. This can either be accomplished with twisted pair cable or a bundled multiple pair cable. See ee Figure 6. The second type of structure is multidrop wiring. This can be used when the HART enabled transmitters are operating in digital communication only. The transmitters may be wired with a trunk and drop layout (or a Daisy Chain). See ee Figure 7. Either of these methods greatly reduce wiring and allow for the most flexibility in expansion. 4 Figure 6 - Point-to-Point Example Figure 7 - Multidrop Example 3000 Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

79 HART Cable Specifications The maximum HART cable length is 1500 meters. However, the physical media is limited by a maximum system attenuation of 3 db. This is ensured if there is a resistance-capacitance combination having an RC time-constant value of 65 µf (the circuit resistance R divided by the capacitance C). The system design must consider both resistance of the device and the cable, likewise the capacitance of the device and the cable. In a typical system the host load resistance is 250Ω. HART recommends a maximum capacitance of 5000 pf on slave devices. Devices with higher capacitance must list the capacitance number (CN). This number equals the actual device capacitance divided by 5000 pf. For example, a device with a capacitance of 10,000 pf would have CN = 2. Resistance is measured for both conductors in series. Capacitance is measured from one conductor to all others and the screen. The values for cables are as follows: Cable Type Description Capacitance Pair Resistance H40 H120 H190 HM40 2 X 22 AWG + 20 Device Ground 4 Pair, 2 X 22 AWG + 18 AWG Device Ground 8 Pair, 2 X 22 AWG + 18 AWG Device Ground 2 X 18 AWG + Device Ground 150 pf/m 190 pf/m 260 pf/m 140 pf/m 112Ω/1000 m 112Ω/1000 m 112Ω/1000 m 43Ω/1000 m The maximum cable distance is dependent on the cable type and the total capacitance of the devices. The graph below provides guidelines for cable distances based on the standard cable and assuming a 250Ω load resistor. In the example if the system consisted of 9 devices with an average CN of 2 (i.e. 10,000 pf each) and a host with 5000 pf capacitance, which totals µf (95,000 pf), the maximum cable length would be 900 meters using multidrop structure cable HM40. Maximum Cable Length 250 ohm Load Resistor otal(µf) Device C Total H40 H120 H190 HM Length (meters) HART simulation software to determine maximum lengths can be found at The software H-SIM can be downloaded free of charge Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

80 HART - Cable Specifications A B C D Twisted pair cable, screened as individual pairs as specified in HART Field Communication Protocol Technical Overview. Data Pair Device Ground Outer Jacket Shield 4 Type Approvals AWG Color Code DCR (/1000 ft) Insulation AWG Color Code Material Color minal O.D. Type Drain Wire Network Standard Ref. H C 300V N EC PLTC C EC [CMG] 2/22 AWG Blue/Brn 16.5 Ohms PE 20 AWG Green/Yellow PVC Grey 7.2mm (.285 in.) Foil 22 AWG RB50824-*M A H40 40A 105 C 300V N EC ITC PLTC C EC [CMG] 2/18 AWG Blue/Brn 6.5 Ohms PE 18 AWG Green/Yellow Armor/PVC Grey 7.9mm (.310 in.) Foil 18 AWG RB50939-*M B H C 300V N EC ITC PLTC/CM C EC [CMG HLBCD] 4 Pairs 2/22 AWG 16.5 Ohms PE 18 AWG Green/Yellow PVC Grey 12.7mm (0.5 in.) Foil 18 AWG RB50825-*M D H C 300V N EC ITC PLTC/CM C EC [CMG HLBCD] 8 Pairs 2/22 AWG 16.5 Ohms PE 18 AWG Green/Yellow PVC Grey 12.7mm (0.5 in.) Foil 18 AWG RB50826-*M C HM4 M C 300V N EC PLTC C EC [ CMG] ] 2/18 AWG Blue/Brn 6.5 Ohms PE ne PVC Grey 7.9mm (.310 in.) Foil 20 AWG RB50938-*M A 3000 Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

81 HART - Cables and Cordsets minifast eurofast Pin (Male) Socket (Female) Pin (Male) RSV WSV RKV WKV RSCV Bare RSV H x 4 x - *M WSV H x 4 x - *M RKV H x 4 x - *M WKV H x 4 x - *M RSCV H x 4 x - *M minifast eurofast Socket (Female) Pin (Male) Socket (Female) Pin (Male) RSV WSV RKV WKV RSCV WSCV RKCV WKCV RSV RSV H x 4 x - *M RSV WSV H x 4 x - *M RSV RKV H x 4 x - *M RSV WKV H x 4 x - *M RSV RSCV H x 4 x - *M WSV WSV H x 4 x - *M WSV RKV H x 4 x - *M WSV WKV H x 4 x - *M WSV RSCV H x 4 x - *M RKV RKV H x 4 x - *M RKV WKV H x 4 x - *M RKV RSCV H x 4 x - *M WKV WKV H x 4 x - *M WKV RSCV H x 4 x - *M RSCV RSCV H x 4 x - *M Indicates cable type * Indicates length in meters Consult factory for availability of armorfast with eurofast connectors. Armorfast cable only For nickel-plated brass coupling nut: RSV...to RSM... RSCV...to RSC... Bulk cable, see page 8 for standard lengths. Example WSV RSCV H40-1M 1 METER Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

82 HART - Cables and Cordsets eurofast minifast bulkhead eurofast bulkhead Pin (Male) Socket (Female) Pin (Male) Socket (Female) Pin (Male) Socket (Female) WSCV RKCV WKCV RSFPV RKFPV FSFDV FKFDV WSCV H x 4 x - *M RKCV H x 4 x - *M WKCV H x 4 x - *M RSFPV H x 4 x - *M RKFPV H x 4 x - *M FSFDV H x 4 x - *M FKFDV H x 4 x - *M RSV WSCV H x 4 x - *M RSV RKCV H x 4 x - *M RSV WKCV H x 4 x - *M RSV RSFPV H x 4 x - *M RSV RKFPV H x 4 x - *M RSV FSFDV H x 4 x - *M RSV FKFDV H x 4 x - *M WSV WSCV H x 4 x - *M WSV RKCV H x 4 x - *M WSV WKCV H x 4 x - *M WSV RSFPV H x 4 x - *M WSV RKFPV H x 4 x - *M WSV FSFDV H x 4 x - *M WSV FKFDV H x 4 x - *M RKV WSCV H x 4 x - *M RKV RKCV H x 4 x - *M RKV WKCV H x 4 x - *M RKV RSFPV H x 4 x - *M RKV RKFPV H x 4 x - *M RKV FSFDV H x 4 x - *M RKV FKFDV H x 4 x - *M WKV WSCV H x 4 x - *M WKV RKCV H x 4 x - *M WKV WKCV H x 4 x - *M WKV RSFPV H x 4 x - *M WKV RKFPV H x 4 x - *M WKV FSFDV H x 4 x - *M WKV FKFDV H x 4 x - *M RSCV WSCV H x 4 x - *M RSCV RKCV H x 4 x - *M RSCV WKCV H x 4 x - *M RSCV RSFPV H x 4 x - *M RSCV RKFPV H x 4 x - *M RSCV FSFDV H x 4 x - *M RSCV FKFDV H x 4 x - *M WSCV WSCV H x 4 x - *M WSCV RKCV H x 4 x - *M WSCV WKCV H x 4 x - *M WSCV RSFPV H x 4 x - *M WSCV RKFPV H x 4 x - *M WSCV FSFDV H x 4 x - *M WSCV FKFDV H x 4 x - *M 4 RKCV RKCV H x 4 x - *M RKCV WKCV H x 4 x - *M RKCV RSFPV H x 4 x - *M RKCV RKFPV H x 4 x - *M RKCV FSFDV H x 4 x - *M RKCV FKFDV H x 4 x - *M WKCV WKCV H x 4 x - *M WKCV RSFPV H x 4 x - *M WKCV RKFPV H x 4 x - *M WKCV FSFDV H x 4 x - *M WKCV FKFDV H x 4 x - *M 3000 Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

83 minifast Cordset and Receptacle Connector Dimensions and Pinouts RSV-* RKV-* WSV-* WKV-* RSFPV-* -* RKFPV-* -* Mounting Installation Male Female 1. Blue (-Voltage) 2. Brown (+ Voltage) 3. Bare (Shield Drain Wire) 4. Green/Yellow (Ground) Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

84 eurofast Cordset and Receptacle Connector Dimensions and Pinouts RSCV-* RKCV-* WSCV-* -* WKCV-* -* FSFDV-* -* FKFDV-* -* Mounting Installation 4 Male Female 1. Blue (-Voltage) 2. Brown (+ Voltage) 3. Bare (Shield Drain Wire) 4. Green/Yellow (Ground) 3000 Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

85 HART - Cables and Cordsets multifast Pin (Male) Socket (Female) CSM CSWM CKM CKWM Bare CSM H1 xx -*M CSWM H1 xx -*M CKM H1 xx -*M CKWM H1 xx -*M multifast Socket (Female) Pin (Male) CSM CSWM CKM CSM CSM H1 xx -*M CSM CSWM H1 xx -*M CSM CKM H1 xx -*M CSM CKWM H1 xx -*M CSWM CSWM H1 xx -*M CSWM CKM H1 xx -*M CSWM CKWM H1 xx -*M CKM CKM H1 xx -*M CKM CKWM H1 xx -*M CKWM CKWM H1 xx -*M CKWM Coupling nuts shown are nickel-plated brass. Consult factory for availability of stainless steel. Indicates cable type Indicates length in meters * CSWM CKM H1-1M Bulk cable, see page 8 for standard lengths. Example 1 METER Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

86 multifast Receptacle Connector Dimensions and Pinouts CSM...CKM... CSWM...CKWM... Functional Wiring Diagram for 12-Pin Cordset Functional Wiring Diagram for 19-Pin Cordset NAMUR HART Color NAMUR HART Color J1 J2 J3 J4 V + V - Drain V + V - Drain V + V - Drain V + V - Drain Ground Drain V - V + Drain V - V + Drain V - V + Drain V - V + Drain Ground Drain J1 J2 J3 J4 J5 J6 J7 J8 V + V - Drain V + V - Drain V + V - Drain V + V - Drain V + V - Drain V + V - Drain V + V - Drain V + V - Drain Ground Drain V - V + Drain V - V + Drain V - V + Drain V - V + Drain V - V + Drain V - V + Drain V - V + Drain V - V + Drain Ground Drain 4 Male Female Male Female 12-pin 12-pin 19-pin 19-pin 3000 Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

87 HART Junction Tee Description The HART junction tee provides a rugged connection to all of your fieldbus devices. Mechanically rugged, the new overmolded design provides unparalled corrosive resistance. It is also available with either multifast connectors for point-to-point wiring, or minifast connectors for multidrop installations. JTBS-40H-CS12 P1 12-Pin Male J0-J4 Dimensions MOUNTING SCREW 1/4 (2) NOT INCLUDED JTBS-70H-CS19 P1 19-Pin Male J0-J7 * change RS to RSV for stainless steel connectors change CS to CSV for stainless steel connectors (consult factory for availability) JTBS-60HM-RS4 P1 4-Pin Male J0-J6 Schematic/ Connector Wiring 4-port Wiring 7-port Wiring Multidrop HART Transmitter NAMUR Sensor Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

88 Quick Selection Guide Part Number Number of Ports Home Run Connector (P1) Connector Size (J0-JX) Overmold Material Connector Material Short Circuit Protected JTBS-40H-CSV12* 4 12-pin multi mini polyurethane stainless steel JTBS-40H-CS pin multi mini polyurethane nickel-plated brass JTBS-70H-CSV19* 7 19-pin multi mini polyurethane stainless steel JTBS-70H-CS pin multi mini polyurethane nickel-plated brass JTBS-40HM-RSV4 4 4-pin mini mini polyurethane stainless steel JTBS-40HM-RS4 4 4-pin mini mini polyurethane nickel-plated brass JTBS-60HM-RSV4 6 4-pin mini mini polyurethane stainless steel JTBS-60HM-RS4 6 4-pin mini mini polyurethane nickel-plated brass * Consult factory for availability Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

89 eurofast Multibox Aluminum Junctions (Bricks) Description Brick for HART ; point-to-point with Home Run connector. Aluminum enclosure Nickel-plated brass connectors Consult factory for availability of stainless steel. VBM-40H-CS12 VBM-80H-CS19 Dimensions Schematic/ Connector HART Transmitter Wiring 4-port Wiring 8-port NAMUR Sensor Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

90 eurofast Multibox Nylon Junctions (Bricks) Description Brick for HART ; point-to-point with Home Run connector Nylon enclosure Nickel-plated brass connectors Consult factory for availability of stainless steel. 4MB12-40H-CS12 8MB12-40H-CS19 Dimensions Schematic/ Connector Wiring 4-port Wiring 8-port 4 HART Transmitter NAMUR Sensor 3000 Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

91 Device Gland Receptacles - 3 wire Selection Guide eurofast minifast 1/2 - NPT FSV H4-*M / 14.5 RSFV H4-*M / /4 - NPT FSV H4-*M / RSFV H4-*M / M20 FSV H4-*M / M20 RSFV H4-*M / M20 * Indicates length in meters. For female receptacles change part number to (FKV, RKFV...). FSV H4-*M / 14.5 RSFV H4-*M / 14.5 FSV H4-*M / RSFV H4-*M / FSV H4 -*M / M20 RSFV H4-*M / M20 Male minifast Female eurofast 1. Blue (-Voltage) 2. Brown (+ Voltage) 3. N/C 4. Green/Yellow (Ground) Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

92 Conduit Adapter minifast eurofast Schematic 2-port 2-port BCA 4HM-M223 BCA 4H-M223 BCA 4HM-E223 BCA 4H-E223 source trunk drop drop drop drop 1-port BCA 4HM-M123 BCA 4HM-E123 trunk drop Description The conduit adapter attaches to a standard conduit body for transition to minifast or eurofast connectors. Gasket and mounting hardware included (8-32 x 1/2 ) Pinout Dimensions 1. Blue (-Voltage) 2. Brown (+ Voltage) 3. N/C 4. Green/Yellow (Ground) CROUSE - HINDS Hub Size = 3/4 Shape Style Part Number 4 C Form 8 Mark 9 C28 C29 Conduit Bodies LB Form 8 Mark 9 LB28 LB29 LL Form 8 Mark 9 LL28 LL29 LR Form 8 Mark 9 LR28 LR29 Conduit connectors for use with armorfast cable O-Z Gedney JMC /2NPT 3000 Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

93 HART Multidrop Tees Part Number RSV 2RKV HM4 Dimensions Description minifast tee data, ground, shield stainless steel coupling nuts RSV FKV RKV HM4 minifast to eurofast drop data, ground, shield stainless steel coupling nuts For nickel-plated brass coupling nuts: Change part number (RSV 2RKV... RSM 2RKM...) For nickel-plated brass coupling nuts: Change part number (RSCV 2RKCV... RSC 2RKC...) Part Number RSCV 2RKCV H4 Dimensions Description eurofast tee stainless steel coupling nuts Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

94 Field Wireable multidrop Tee Description The Field Wireable Tee is a hybrid connection offering system-wide plug-and-play convenience. This allows an extremely rapid changeover to a connectorized network, often in less than 15 minutes. The Field Wireable IP67 Tee SPTTM13-AHM4 features standardized minifast connectors for the drop connection and field wireable terminals on the trunk connections. This provides the best of both worlds, reliable connections on the short lengths and ease of installation planning on the long trunk runs. SPTT1-AHM4 SPTTM13-AHM4 Dimensions 4 Wir ire Table Specifications Pin 1 Designation V - Color Blue 2 V + Brown 3 Shield Bare 4 Ground Green/Yellow 3000 Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

95 Gender Changers and Elbow Connectors Part Number RSV RSV H4 Dimensions Description minifast Male Gender Changer female cordset to male receptacle RKV RKV H4 minifast Female Gender Changer male cordset to female receptacle WSV RKV H4 minifast Elbow right angle male to female connector RSM H4-FK 4.5 minifast to eurofast Adapter minifast male to eurofast female connector nickel-plated brass housing For nickel-plated brass coupling nuts: Change part number (RSV RSV...RSM RSM...) Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

96 Bulkhead Feed-Thru Receptacles panel mount minifast Bulkhead Receptacle straight male/female feed thru RSFV RKF H4/22 For jam nuts or spare nuts order: LN-SS 1/2-14[10/BAG] or LN-SS12[10/BAG] 4 4 eurofast Bulkhead Receptacle straight male/female feed thru FKV FSV H4/M12 For nickel-plated brass coupling nuts change part number: RSFV RKFV H4/22 to RSF RKF H4/22 or FKV FSV H4/M12 to FKM FS H4/M Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

97 Panel Mount Receptacles - minifast, eurofast Selection Guide Female Male Leads minifast eurofast RKFV H4 - *M RSFV H4 - *M FKV H4 - *M FSV H4 - *M Cable minifast eurofast RKFV H40 - *M RSFV H40 - *M FKV H40 - *M FSV H40 - *M * Indicates length in meters. RKFV H4 - *M RSFV H4 - *M FKV H4 - *M FSV H4 - *M Female minifast Male eurofast 1. Blue (-Voltage) 2. Brown (+ Voltage) 3. Bare (Shield Drain Wire) 4. Green/Yellow (Ground) Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

98 Panel Mount Receptacles - multifast Selection Guide Female Male Leads 12-pin CKF H12 CSF H12 19-pin CKF H19 CSF H19 Cable 12-pin 19-pin CKF H120 CKF H190 CSF H120 CSF H190 CKF.... or CSF See page 85 for functional wiring diagram. Male Female Male Female 12-pin 12-pin 19-pin 19-pin 3000 Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

99 Field Wireable Connectors - minifast Selection Guide Aluminum Stainless Steel Female B /9 BV /9 Male BS /9 BSV /9 Accepts 6-8mm cable ( ) B /9 BS /9 BV /9 BSV /9 Male 1. Blue (-Voltage) 2. Brown (+ Voltage) 3. Bare (Shield Drain Wire) 4. Green/Yellow (Ground) Female Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

100 Field Wireable Connectors - eurofast Selection Guide Straight Right Angle Female B8141-0/PG9 B8241-0/PG9 Male BS8141-0/PG9 BS8241-0/PG9 Accepts 6-8mm cable ( ) B8141-0/PG9 B8241-0/PG9 BS8141-0/PG9 BS8241-0/PG9 4 Housing Material PBT Coupling Nut Material - Female - nylon Male - nickel-plated brass Female eurofast 1. Blue (-Voltage) 2. Brown (+ Voltage) 3. Bare (Shield Drain Wire) 4. Green/Yellow (Ground) Male eurofast 3000 Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

101 Field Wireable Connectors - multifast Selection Guide 12-pin* 19-pin** Female CK 12-0 CKV 19-0 Male CS 12-0 CSV 19-0 * Accepts 4-10mm cable ( ) ** Accepts 5-12mm cable ( ) CK.. CS.. Female contact holder, female threads Male contact holder, female threads See page 85 for functional wiring diagram. Male Female 12-pin 19-pin 12-pin 19-pin 100 InterlinkBT 3000 Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

102 Closure Cap Closure caps are for unused ports on the junction box. Dimensions Description RKMV BC minifast closure cap mates to male receptacles Stainless steel IP67 rated RSMV BC minifast closure cap mates to female receptacles Stainless steel IP67 rated RSFK-BC (10/BAG) minifast Closure Cap mates to female receptacles nylon 4 VZ-3 (8/BAG) eurofast Closure Cap mates to female receptacles nylon 3000 Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

103 Index Symbols 4MB12-40H-CS MB12-40H-CS B B / B , 44 B8141-0/PG9...99, 74, 45 B8241-0/PG9...99, 74, 45 BCA 48-E BCA 48-E BCA 48-M BCA 48-M BCA 49-E BCA 49-E BCA 49-M BCA 49-M BCA 4HM-E BCA 4HM-E BCA 4HM-M BCA 4HM-M BRPC-49-M BS / BS /9...98, 44 BS8141-0/PG9...99, 74, 45 BS8241-0/PG9...99, 74, 45 BSV / BSV /9...98, 44 BV / BV /9...98, 44 C CK CKF H CKF H CKF H CKF H CKV Connector Specifications...7 CS CSF H CSF H CSF H CSF H CSV E eurofast Part Number Keys...9 F FKV 48 - *M...72 FKV *M...72 FKV FKV *M...43 FKV FSV 48/M FKV FSV 49/M FKV FSV H4/M FKV H4 - *M...96 FKV H40 - *M...96 FOUNDATION fieldbus - Cable Specifications...17 FOUNDATION fieldbus - Cable and Cordsets FSV 48 - *M...72 FSV *M...72 FSV 48T-*M / FSV 48T-*M / FSV 48T-*M / M FSV FSV 49-*M / FSV 49-*M / FSV 49-*M / M FSV *M...43 FSV 49T-*M / FSV 49T-*M / FSV 49T-*M / M FSV H4 - *M...96 FSV H4-*M / FSV H4-*M / FSV H4-*M / M FSV H40 - *M...96 H HART - Cable Specifications...79 HART - Cables and Cordsets , 84 J JBBS-48-E JBBS-48-E JBBS-48-E JBBS-48-M JBBS-48-M JBBS-48-M JBBS-49-E JBBS-49-E JBBS-49-E JBBS-49-M InterlinkBT 3000 Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

104 Index JBBS-49-M JBBS-49-M JTBS-40H-CS JTBS-48SC-M JTBS-49-I JTBS-49SC-M JTBS-60HM-RS JTBS-70H-CS JTBS Part Number Key...11 M Marine Cable...22 minifast Part Number Keys...10 P PROFIBUS-PA - Cable Specifications...51 PROFIBUS-PA - Cables and Cordsets R RKFV 48 - *M...72 RKFV *M...72 RKFV RKFV *M...43 RKFV H4 - *M...96 RKFV H40 - *M...96 RKGV-*...23 RKMV BC...101, 75, 46 RKV RKV RKV RKV RKV RKV H RSCV 2RKCV RSCV 2RKCV RSCV 2RKCV H RSEV 48-TR...63 RSEV 48-TR-Ex...64 RSEV 49-TR...34 RSFK-BC (10/BAG)...101, 75, 46 RSFV 48 - *M...72 RSFV *M...72 RSFV 48T-*M / RSFV 48T-*M / RSFV 48T-*M / M RSFV RSFV 49-*M / RSFV 49-*M / RSFV 49-*M / M RSFV *M...43 RSFV 49T-*M / RSFV 49T-*M / RSFV 49T-*M / M RSFV H4 - *M...96 RSFV H4-*M / RSFV H4-*M / RSFV H4-*M / M RSFV H40 - *M...96 RSFV RKF 48/ RSFV RKF 49/ RSFV RKF H4/ RSGV-*...23 RSM 48-FK RSM 49-FK RSM H4-FK RSMV BC...101, 75, 46 RSV 2RKV RSV 2RKV RSV 2RKV HM RSV 48-TR...63 RSV 48-TR-Ex...64 RSV 49-TR...34 RSV FKV RKV RSV FKV RKV RSV FKV RKV HM RSV RKV 48 SS...69 RSV RKV 49 SS...39 RSV RSV RSV RSV RSV RSV H S SHLD, EURO...70, 41 SHLD, EURO FW...70, 41 SHLD, MINI...70, 41 SHLD, MINI FW...70, 41 SPTT1-A SPTT1-A SPTT1-AHM SPTTM13-A SPTTM13-A SPTTM13-AHM V VBM-40H-CS VBM-80H-CS VZ-3 (8/BAG)...101, 75, 46 W WSV RKV WSV RKV WSV RKV H Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

105 Visit us at * Link to support.interlinkbt.com Web eb Site Features: es: What s s New: Products: Search: Tech Support: Calendar: Literature: e: Contacts: About Us: Login: Check the latest articles, literature updates and product releases. Complete listing of network cables and cordsets, interconnection products, accessories, I/O stations and modules, I/O systems and more. Use keywords and phrases to locate specific information. See page 123. Check out the events in your area. Contains a complete listing of catalogs, brochures, tutorials, CAD drawings and electronic news releases from. Download pdf files or register for mail copy. Sales - Find reps and distributors in your area. Partners - Lists affiliates and trade associations. Integrators - Contains business summaries and web site links. Us - Submit requests and comments directly to. Contains company information and opportunities. The login page provides access to the secure area for the sales channel. 122 InterlinkBT 3000 Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

106 Visit us at support.interlinkbt.com * Click Tech Support from interlinkbt.com or visit support.interlinkbt.com Technical Support Web eb Site Features: es: App. tes: CAD Library: Config. Files: Documents: Software: Application tes contain documents for approvals and testing, mapping and configuration and application guidelines. Contains Product CAD Files - search by network and/or part number. EDS and GSD file search. Download catalogs, guides, manuals and wiring diagrams. Lists software that is available for download Campus Drive Minneapolis, MN Phone: (01) (763) Fax: (01) (763) Toll Free:

PA Physical Media Connectivity

PA Physical Media Connectivity PROFIBUS Cordsets Receptacles Terminating resistors Tees Field Wireables P24 P21 P28 P30 P34 Features Cable that meets the requirements of ISA/SP 50 and PROFIBUS-PA requirements for Type A Cable All cables

More information

Seriplex. System throughput time is 0.4 msec for 32 sensors plus 32 actuators (5 msec for 510 I/O)

Seriplex. System throughput time is 0.4 msec for 32 sensors plus 32 actuators (5 msec for 510 I/O) TURCK Network Media Products Seriplex Seriplex is designed to be easy and simple to use where applications demand a very high speed. Response times are less than a millisecond for 128 points. Cable runs

More information

CC-Link. Simple communication programming - configuration software available but not required

CC-Link. Simple communication programming - configuration software available but not required (Control & Communication Link) is a field network system that processes control and information data at high speed while ensuring a deterministic response. Features include: Simple communication programming

More information

PROCESS WIRING. TURCK Inc Campus Drive Minneapolis, MN Application Support: Fax: (763)

PROCESS WIRING. TURCK Inc Campus Drive Minneapolis, MN Application Support: Fax: (763) Process Automation PROCESS WIRING TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-553-0016 Fax: (763) 553-0708 www.turck.com K2 TURCK Process Wiring Products TURCK Process

More information

Data Highway Plus (Blue Hose )

Data Highway Plus (Blue Hose ) TURCK Network Media Products Data Highway Plus (Blue Hose ) The Data Highway Plus (DH+) network is a local area network that is very simple to implement. It is designed to provide simple communication

More information

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA Main Office: (650) Outside Local Area: (800)

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA Main Office: (650) Outside Local Area: (800) Industrial Automation Network Media Introduction.................... A1 Standard Cordset Lengths...................... A7 Part Number Keys.......................... A8 DeviceNet /CANopen.......................

More information

DeviceNet Physical Media Connectivity

DeviceNet Physical Media Connectivity Part Number Keys Cordsets Receptacles Field Wireables M4 M10 M39 M46 DeviceNet Media Features Cables that meet the requirements of the ODVA PLTC rated cable Available in thin, mid, and thick styles 7/8

More information

THE FULL RANGE FOR PROCESS AUTOMATION. This document provided by Barr-Thorp Electric Co., Inc

THE FULL RANGE FOR PROCESS AUTOMATION.  This document provided by Barr-Thorp Electric Co., Inc THE FULL RANGE FOR PROCESS AUTOMATION www.turck.com TURCK Process Automation Networks PROFIBUS -DP Selection Guide AIM Discrete Input Discrete Output Discrete Input & Ouput Page H11 H17 H21 FDP20 Repeater

More information

IDC Field Wireable eurofast & picofast Connectors

IDC Field Wireable eurofast & picofast Connectors Advanced Connection Solutions for Manufacturers Worldwide! IDC Field Wireable eurofast & picofast Connectors picofast Field Wireable IDC Connector eurofast Field Wireable IDC Connector Overview Connection

More information

TURCK Industrial Connectivity Products

TURCK Industrial Connectivity Products TURCK Industrial Connectivity Products General Accessories Liquid Tight Strain Relief Cable Glands Lock Nuts Page R2 - R4 Page R6 Snap-in Labels Strain Relief Cord Grips Page R5 Page R5 Protective Sleeving

More information

1/2 microfast Connectivity

1/2 microfast Connectivity Part Number Keys Cordsets Receptacles Field Wireables Adapters E2 E4 E8 E16 E17 microfast Features y 2 to 6 pin y Up to 4 Amp, 250 Volt rated y IEC IP67 protection y NEMA 6P rated y Low current AC applications

More information

Connectivity Products

Connectivity Products Cable Glands Strain Relief Snap-In Labels Lock Nuts Torque Wrench Protective Sleeves U2 U5 U5 U6 U7 U8 Features NPT and PG thread cable glands in nylon or metal materials Locknuts in multiple thread sizes

More information

Networks/ Fieldbus. Overview Guide.

Networks/ Fieldbus. Overview Guide. Networks/ Fieldbus Overview Guide www.turck.com TURCK Network Overview Register to receive the TURCK TIMES Our interactive e-newsletter full of exclusive insights, tips and tools to help make your manufacturing

More information

EtherNet Physical Media Connectivity

EtherNet Physical Media Connectivity Part Number Keys Cordsets Receptacles EtherNet/IP Cordsets Field Wireables K3 K6 K13 K16 K24 EtherNet Features CAT 5E rated cables 2 pair and 4 pair cable option 8-pin and 4-pin D-coded connectors M12

More information

TURCK Industrial Connectivity Products

TURCK Industrial Connectivity Products TURCK Industrial Connectivity Products multibox eurofast Junction Boxes, 4-Ports Rugged Plastic Housing with Flush Connectors Available with or without LEDs Quick Disconnect or minifast Connector 4-, 2-Signals

More information

TURCK Industrial Connectivity Products

TURCK Industrial Connectivity Products TURCK Industrial Connectivity Products multibox eurofast Low Profile Junction Boxes Single Output per Port Rugged Plastic Housing Available with or without LEDs M23 Quick Disconnect Integral Home Run Cable

More information

Pile Driver Weld Immune Sensors

Pile Driver Weld Immune Sensors DC... 190 8, 12, 18, and 30 mm Diameter... 190 3- and 4-Wire DC... 192 8, 12, 18, and 30 mm Diameter... 192 AC/DC... 194 12, 18, and 30 mm Diameter... 194 Pile Driver Sensors P+F s weld immune Pile Driver

More information

AC Micro Style Cordsets and Receptacles

AC Micro Style Cordsets and Receptacles AC Micro Style Cordsets and Receptacles Description Rockwell Automation/Allen-Bradley offers a wide variety of connection products for interfacing field devices to I/O, junction boxes, PLCs, etc. Connection

More information

NEW. TURCK Inductive Sensors - Specialty DS20

NEW. TURCK Inductive Sensors - Specialty DS20 TURCK Inductive Sensors - Specialty DS0 Sensor Selection Part Number Material Housing: Sensing Face: Connector: Chrome Plated Brass Field Wireable Connector(S578/S579): PBT Conduit Adapter (S578/S579):

More information

THE FULL RANGE FOR PROCESS AUTOMATION. This document provided by Barr-Thorp Electric Co., Inc

THE FULL RANGE FOR PROCESS AUTOMATION.   This document provided by Barr-Thorp Electric Co., Inc THE FULL RANGE FOR PROCESS AUTOMATION www.turck.com TURCK Process Automation Networks DeviceNet Selection Guide AIM Page FDN20 Page OEM Page Discrete Input J11-J13, J29, J37 Discrete Input & Ouput J59

More information

Industrial Ethernet Cordsets including PROFINET

Industrial Ethernet Cordsets including PROFINET Network Media TURCK offers a complete line of molded industrial networking cordsets to aid network installation, providing easier startup with fewer wiring errors. We are dedicated to providing solutions

More information

Sensor Connectivity Introduction Global Plus Connector Cables Multi-Connector Blocks. Product Selection Guide...

Sensor Connectivity Introduction Global Plus Connector Cables Multi-Connector Blocks. Product Selection Guide... .0 Introduction Product Selection Guide.................................... Product Description....................................... Standards and Certifications................................ Product

More information

07. har-link Interface Connectors

07. har-link Interface Connectors . Interface Connectors The highest data rates in combination with perfect shielding characterize the connector. This way data can be passed on optimally within the control cabinet. The locking mechanism

More information

TURCK Industrial I/O DeviceNet Products

TURCK Industrial I/O DeviceNet Products TURCK Industrial I/O DeviceNet Products F1 TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com Industrial Automation DeviceNet System

More information

Ethernet Media. Technical Data. Cable Spools 2. Cordsets & Patchcords 5. Patchcords & Field Attachables 12

Ethernet Media. Technical Data. Cable Spools 2. Cordsets & Patchcords 5. Patchcords & Field Attachables 12 Technical Data Ethernet Media Bulletin Numbers 585, 585A, 585BP, 585BT, 585BX, 585BZ, 585D, 585J Topic Page Cable Spools Cordsets & Patchcords 5 Patchcords & Field Attachables Cable Spools Unshielded Twisted

More information

Ethernet Media. Technical Data. Cable Spools 2. Cordsets & Patchcords 5. Patchcords & Field Attachables 10

Ethernet Media. Technical Data. Cable Spools 2. Cordsets & Patchcords 5. Patchcords & Field Attachables 10 Technical Data Ethernet Media Bulletin Numbers 585, 585A, 585BP, 585BT, 585BX, 585BZ, 585D, 585J Topic Page Cable Spools Cordsets & Patchcords 5 Patchcords & Field Attachables 0 Cable Spools Unshielded

More information

Accessories Fieldbus Box

Accessories Fieldbus Box Power cables, sensor cables, connection cables and further accessories see the EtherCAT Box chapter from page 514 Pre-assembled cables for fieldbus components include a wide range of cable assemblies.

More information

ArmorConnect Power and Control Media

ArmorConnect Power and Control Media Selection Guide ArmorConnect Power and Control Media Bulletins 280, 888, 889, 898 2 Bulletin 280, 888, 889, 898 Power Media Product Overview Media Description Features Trunk Cable Cordset - Cable with

More information

TURCK Modular Industrial I/O PROFIBUS -DP Products

TURCK Modular Industrial I/O PROFIBUS -DP Products TURCK Modular Industrial I/O PROFIBUS -DP Products Piconet Gateways Rugged, Fully Potted Stations IP 67 Protection Small Footprint Automatic Baud Rate Sensing SDPL-0404D-0003 SDPL-0404D-0004 SDPL-0404D-1003

More information

TURCK Industrial Wiring Solutions

TURCK Industrial Wiring Solutions 4-port, Snap Lock, 10-48 VDC multibox picofast Junction Box, 4-port Snap Lock or Threaded Connections Available with or without LEDs TURCK Industrial Wiring Solutions Quick Disconnect or Integral Home

More information

picofast 4 - Branch Molded Junctions, Standard Wiring

picofast 4 - Branch Molded Junctions, Standard Wiring picofast 4 - Branch Molded Junctions, Standard Wiring Combine 4 Sensors into One Cable Tough Polyurethane Construction For 3-wire DC Sensors or Switches Application Specifications Wiring Diagram Housing

More information

Better all-round. DataVoice Circular connectors STX M12x1 IP67 Connector series for industrial applications. PoE+ 10 GBE. coded.

Better all-round. DataVoice Circular connectors STX M12x1 IP67 Connector series for industrial applications. PoE+ 10 GBE. coded. Better all-round. X coded D coded 10 GBE PoE+ DataVoice Circular connectors STX M12x1 IP67 Connector series for industrial applications STX M12x1 IP67 connector series With the STX M12x1 IP67 connector

More information

Environmentally Sealed

Environmentally Sealed Weather-Pack 16 Metri-Pack 19 AMP Superseal 24 Ampseal 16 27 M12 Network 30 DIN Connectors 31 Schlemmer / Din Conduit Sealed 32 Schlemmer / Din Contact Sealed 34 Ideal for applications requiring protection

More information

Complete the Installation SKINTOP MS-SC. Color Code: Approvals: Nominal Outer Diameter

Complete the Installation SKINTOP MS-SC. Color Code: Approvals: Nominal Outer Diameter BUS UNITRONIC BUS PB For PROFIBUS-DP/FMS/FIP bus systems; stationary applications; 150 Ω UNITRONIC BUS PB UNITRONIC BUS PB FC UNITRONIC BUS PROFIBUS cables are designed for automation networks requiring

More information

Rotary Measurement Technology Absolute Encoders, Singleturn

Rotary Measurement Technology Absolute Encoders, Singleturn -40 to 80 C IP Safety-LockTM High rotational speed Temperature High IP High shaft load capacity Shock/ vibration resistant Magnetic field proof Short-circuit proof Reverse polarity protection Reliable

More information

IP68 Sealed - Mini USB Buccaneer

IP68 Sealed - Mini USB Buccaneer IP68 Sealed - IP68 Over moulded assembly provides IP68 cable seal Coupling ring, screw thread provides secure cable coupling Mini USB connector O ring maintains IP68 seal at connector interface Mini USB

More information

Model 675 DREXELBROOK. Shark Cage Submersible Level Transmitter DATA SHEET. Description. Features. Applications.

Model 675 DREXELBROOK. Shark Cage Submersible Level Transmitter DATA SHEET. Description. Features. Applications. DREXELBROOK DATA SHEET Model 675 Shark Cage Model 675 Shark Cage with 3.5" flush diaphragm pressure via its sensing element, an ion implanted silicon semiconductor chip with integral Wheatstone Bridge

More information

Rotary Position Technology Incremental Encoders

Rotary Position Technology Incremental Encoders -40 to 85 C IP Safety-Lock High rotational speed Temperature High IP High shaft load capacity Shock/vibration resistant Magnetic field proof Short-circuit proof Reverse polarity protection Optical sensor

More information

THE FULL RANGE FOR PROCESS AUTOMATION. This document provided by Barr-Thorp Electric Co., Inc

THE FULL RANGE FOR PROCESS AUTOMATION.   This document provided by Barr-Thorp Electric Co., Inc THE FULL RANGE FOR PROCESS AUTOMATION www.turck.com TURCK Process Automation Networks Ethernet Ethernet I/O Selection Guide BL67 Gateway F5 - F8 AS-i Gateway F9 - F16 Ethernet 8-wire Selection Guide Cables

More information

Flow Measurement SITRANS F US Inline

Flow Measurement SITRANS F US Inline Overview Function Displays and keypad Operation of the SITRANS FUS060 transmitter can be carried out using: Keypad and display unit HART communicator PC/laptop and SIMATIC PDM software via HART communication

More information

Flow Measurement SITRANS F US Inline

Flow Measurement SITRANS F US Inline Overview Function Displays and keypad Operation of the SITRANS FUS060 transmitter can be carried out using: Keypad and display unit HART communicator PC/laptop and SIMATIC PDM software via HART communication

More information

07. har-link INTERFACE CONNECTORS

07. har-link INTERFACE CONNECTORS . INTERFACE CONNECTORS The highest data rates in combination with perfect shielding characterize the connector. This way data can be passed on optimally within the control cabinet. The locking mechanism

More information

TURCK Process Automation IS Interface Technology. Interface Modules. IM Series Cabinet

TURCK Process Automation IS Interface Technology. Interface Modules. IM Series Cabinet Process Automation IS Interface Technology Interface Modules TURCK's IM series of Isolating Intrinsically Safe Barriers is designed to be a simple and safe way to solve the problems associated with the

More information

Telephony Multi-Taps. 9000T-TP Series

Telephony Multi-Taps. 9000T-TP Series 9000T-TP Series The 9000T-TP series 1 GHz twisted-pair power multi-tap taps off part of its input RF and AC, but lets the rest pass through. It divides the tapped-off signal and power into multiple outputs,

More information

Product Data. Model 675 Shark Cage Submersible Level Transmitter ELECTRONIC PRESSURE MEASUREMENT PRODUCTS DESCRIPTION FEATURES APPLICATIONS

Product Data. Model 675 Shark Cage Submersible Level Transmitter ELECTRONIC PRESSURE MEASUREMENT PRODUCTS DESCRIPTION FEATURES APPLICATIONS EPMP - 1 DESCRIPTION The Model 675 is specifically designed for slurry and highly viscous applications where clogging of the sensor area is common. The Model 675 uses a 3.5" flush diaphragm to prevent

More information

Han-Brid. Contents Han-Brid Features Han-Brid Data interfaces Han-Brid Overview Han-Brid Cu

Han-Brid. Contents Han-Brid Features Han-Brid Data interfaces Han-Brid Overview Han-Brid Cu Contents Page Features... 19.02 Data interfaces... 19.03 Overview... 19.04 Cu... 19.06 F.O.... 19.08 Quintax 3 A... 19.10 RJ45 C... 19.12 USB / FireWire... 19.14 Han 4 A SC... 19.16 Hoods/Housings... 19.18

More information

Dual Module VCT. 5. Lexan Enclosure is Water & Corrosion Proof Contaminants will not affect the module as long as terminal strip is not immersed.

Dual Module VCT. 5. Lexan Enclosure is Water & Corrosion Proof Contaminants will not affect the module as long as terminal strip is not immersed. 2 The integrates position sensing, communication electronics, power outputs, auxiliary inputs and wire termination into a fully sealed compact package. The module also integrates a terminal strip directly

More information

µcom-10gb + MAIN FEATURES FEATURES AND BENEFITS MARKETS & APPLICATIONS Harsh Environment 10Gb Ethernet Micro Connectors Amphenol Socapex

µcom-10gb + MAIN FEATURES FEATURES AND BENEFITS MARKETS & APPLICATIONS Harsh Environment 10Gb Ethernet Micro Connectors Amphenol Socapex Harsh Environment 10Gb Ethernet Micro Connectors 15mm µcom-series is a new range of connectors designed to address the latest trends of the industry : miniaturization and high speed, with the highest resistance

More information

FieldLink process networking

FieldLink process networking FieldLink process networking Enclosures Junction module (JM) StoneL s Junction Module (JM) enclosure is an environmetally hardened platform which is suitable for use in the most extreme corrosive and hazardous

More information

400 Series - Mini USB Buccaneer

400 Series - Mini USB Buccaneer IP68 Sealed IP68 rated IP69K, Tested in accordance with DIN 40050/Part 9 IP6k9k USB V2.0 performance Plug and play capability Shielded system Overmoulded cables Screw coupling PCB versions Dust and waterproof

More information

Rotary Measurement Technology Absolute Encoders, Multiturn

Rotary Measurement Technology Absolute Encoders, Multiturn -40 to 80 C IP Mechanical drive Safety-LockTM High rotational speed Temperature High IP High shaft load capacity Shock/ vibration resistant Magnetic field proof Short-circuit proof Reverse polarity protection

More information

Ethernet Series. Etherplug Etherlink V Etherlink V Specifications Ethernet Series

Ethernet Series. Etherplug Etherlink V Etherlink V Specifications Ethernet Series Etherplug... 10-113 Etherlink V3...114-116 Etherlink V1... 117-120 Specifications..121-122 107 Mencom Corporation TEL: 770-534-455 www.mencom.com Etherplug Cordsets PVC & PUR Cable Pole PVC Version of

More information

Ethernet Media. Introduction Quick Selection Ethernet Media. Systems. PannelConnect Connection. Connection. Safety.

Ethernet Media. Introduction Quick Selection Ethernet Media. Systems. PannelConnect Connection. Connection. Safety. Table of Contents Guide...7-2...7-3 Unshielded Twisted Pair...7-5 Shielded Twisted Pair...7-6 600V Ethernet Cable...7-7 Cordsets & Patchcords RJ45...7-9 M12 Flex-Rated...7-10 M12 Receptacle Flex-Rated...7-12

More information

Rotary Measurement Technology Absolute Encoders, Multiturn

Rotary Measurement Technology Absolute Encoders, Multiturn -40 to 80 C IP Mechanical drive Safety-LockTM High rotational speed Temperature High IP High shaft load capacity Shock/ vibration resistant Magnetic field proof Short-circuit proof Reverse polarity protection

More information

Installation & Operation Manual

Installation & Operation Manual Via Enrico Fermi, 2 I-25015 Desenzano del Garda (BS) - Italy Phone: +39 030 7870787 Fax: +39 030 7870777 www.solexy.net BAF Intrinsically Safe Ethernet Coupler for signals operating in Hazardous Areas

More information

11 PROFIBUS Fieldbus Connector

11 PROFIBUS Fieldbus Connector 750-960 PROFIBUS Fieldbus Connector 634 54 mm> < < 45mm 5 < 36,7mm < 372 mm < 54 mm < 36 mm / 42 in < 5-6 mm / 022 in < 0 mm / 0394 in The fieldbus connector links a PROFIBUS device

More information

BL compact multiprotocol fieldbus station for Industrial Ethernet 8 Analog Inputs for Current or Voltage BLCEN-8M12LT-4AI-VI-4AI-VI

BL compact multiprotocol fieldbus station for Industrial Ethernet 8 Analog Inputs for Current or Voltage BLCEN-8M12LT-4AI-VI-4AI-VI On-machine Compact fieldbus I/O block EtherNet/IP, Modbus TCP, or PROFINET slave Integrated Ethernet Switch 10 Mbps / 100 Mbps supported Two 4-pole M12, D-coded, connectors for fieldbus connection 2 rotary

More information

DIN Molded Cable Assemblies

DIN Molded Cable Assemblies DIN 43650 Telephone (973) 586-500 FAX (973) 596-590 DIN 43650 8mm For Solenoid Valve Applications Black PVC Cable & Connector DUAL JUMPED GROUND PINS Molded cable assemblies can be mounted with cable exiting

More information

WINSTA. Full Line Catalog 2008/2009

WINSTA. Full Line Catalog 2008/2009 WINSTA Full Line Catalog 2008/2009 5 Contents FULL LINE CATALOG W4, Volume 1 Rail-Mounted Terminal Block Systems FULL LINE CATALOG W4 Rail-Mounted Terminal Blocks Volume 1 X-COM -SYSTEM Terminal Strips

More information

Thread length (overall length) material

Thread length (overall length) material Cylindrical Proximity Sensor for Mobile Usage Designed and tested to keep your machines moving IP69k tested and certified for highest water resistance e1 type approval (according to automotive directive

More information

µcom-10gb + Amphenol MAIN FEATURES FEATURES AND BENEFITS MARKETS & APPLICATIONS Harsh Environment 10Gb Ethernet Micro Connectors

µcom-10gb + Amphenol MAIN FEATURES FEATURES AND BENEFITS MARKETS & APPLICATIONS Harsh Environment 10Gb Ethernet Micro Connectors Harsh Environment 10Gb Ethernet Micro Connectors 15mm µcom-series is a new range of connectors designed to address the latest trends of the industry : miniaturization and high speed, with the highest resistance

More information

PROFIBUS Fieldbus Connector 634

PROFIBUS Fieldbus Connector 634 750-960 PROFIBUS Fieldbus Connector 634 54 mm> < < 45mm < 36,7mm < 372 mm < 54 mm < 36 mm / 142 in < 5-6 mm / 022 in < 10 mm / 0394 in The fieldbus connector links a PROFIBUS

More information

On-Machine Modular I/O

On-Machine Modular I/O ON-MACHINE MODULAR I/O On-Machine Modular I/O On-machine (IP67) modular I/O does not require an enclosure, allowing it to be mounted directly on the machine. TURCK on-machine modular I/O offers quick connection

More information

Bulletin 871D Cylinder Position Inductive Style

Bulletin 871D Cylinder Position Inductive Style Bulletin 871D Cylinder Position Inductive Style Description Bulletin 871D cylinder position inductive proximity sensors are self-contained solid state devices. These devices are designed for sensing metal

More information

APPLICATION GUIDE. Interface Modules IM Series.

APPLICATION GUIDE. Interface Modules IM Series. Interface Modules IM Series APPLICATION GUIDE www.turck.com Interface Technology Interface Modules TURCK's IM series of Isolating Intrinsically Safe Barriers is designed to be a simple and safe way to

More information

EPIC Circular Connectors CIRCON M23 Series

EPIC Circular Connectors CIRCON M23 Series The M3 connectors have many inherent features which offer application advantages and provide significant benefits for the customer. These features make it one of the most application friendly connectors

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS www.altroniccontrols.com INSTALLATION INSTRUCTIONS EXACTA 21 MONITORING AND CONTROL SYSTEM CAUTION: The EXACTA 21 CONTROL SYSTEM is CSA CERTIFIED FOR use in Class I, GROUPS C & D, Division 2 hazardous

More information

E2A. Ordering Information. Cylindrical Proximity Sensor. Safe Mounting with Greater Sensing Distance. E2A Cylindrical Proximity Sensor 1

E2A. Ordering Information. Cylindrical Proximity Sensor. Safe Mounting with Greater Sensing Distance. E2A Cylindrical Proximity Sensor 1 Cylindrical Proximity Sensor E2A Safe Mounting with Greater Sensing Distance Ensures a sensing distance approximately 1. to 2 times larger than that of any conventional OMRON Sensor. Problems such as the

More information

07. har-link Interface Connectors

07. har-link Interface Connectors . Interface Connectors The highest data rates in combination with perfect shielding characterize the connector. This way data can be passed on optimally within the control cabinet. The locking mechanism

More information

EN3 SERIES WEATHERTIGHT CONNECTORS NEW PRODUCT BULLETIN 602

EN3 SERIES WEATHERTIGHT CONNECTORS NEW PRODUCT BULLETIN 602 FEATURES & BENEFITS Sealed to IP68 NEMA 250 (6P) Patented grommet & o-ring free design Available in ribbed or winged coupling ring Cable, panel & cable to cable options Gold plated contacts standard Solder,

More information

Operating voltages up to 40 kvdc Operating current up to 30 Amps Advanced contact technology Silver plated and gold plated contacts available High

Operating voltages up to 40 kvdc Operating current up to 30 Amps Advanced contact technology Silver plated and gold plated contacts available High Operating voltages up to 40 kvdc Operating current up to 30 Amps Advanced contact technology Silver plated and contacts available High performance insulation material General characteristics and technical

More information

Amphenol Miniature Cylindrical Proprietary/MIL-C-26482, Series 1

Amphenol Miniature Cylindrical Proprietary/MIL-C-26482, Series 1 Amphenol Miniature Cylindrical Proprietary/ PT PT-SE SP 3 DESIGN CHARACTERISTICS Medium size, widely used cylindrical Operating voltage to 1,000 VAC (RMS) at sea level Environment resistant Quick positive

More information

1993 SPECIFICATIONS CSJ , ETC. & SPECIAL SPECIFICATION ITEM 6132 ARTERIAL TRAFFIC MANAGEMENT SYSTEM

1993 SPECIFICATIONS CSJ , ETC. & SPECIAL SPECIFICATION ITEM 6132 ARTERIAL TRAFFIC MANAGEMENT SYSTEM 1993 SPECIFICATIONS CSJ 1685-05-068, ETC. & 1685-02-042 1.0 DESCRIPTION SPECIAL SPECIFICATION ITEM 6132 ARTERIAL TRAFFIC MANAGEMENT SYSTEM THIS ITEM DESCRIBES THE OPERATION AND INSTALLATION OF AN ARTERIAL

More information

PROFIBUS Repeater PRC P PROFIBUS Converter PCF PF P PROFIBUS Converter PCF PF P20.05

PROFIBUS Repeater PRC P PROFIBUS Converter PCF PF P PROFIBUS Converter PCF PF P20.05 Contents chapter age General information............................... 00 Repeater.......................................... 10 Repeater RC 67-10............................... 10.01 Converter.........................................

More information

Standard Buccaneer - Ethernet

Standard Buccaneer - Ethernet IP6 rated IP69K, Tested in accordance with DIN 40050/Part 9 IP6k9k or compliant PUR / PVC jacket on cable Shielded system or shielded coupler Shroud on RJ45 Screw coupling Rewireable flex connector PCB

More information

RJF RB Ethernet connection system for harsh environment Industrial Ethernet

RJF RB Ethernet connection system for harsh environment Industrial Ethernet RJF RB Ethernet connection system for harsh environment Industrial Ethernet ROHS compliant RJFRB allows you to use an Ethernet Class D / Cat 5e and Class E / Cat 6 connection for 10 BaseT, 100 BaseTX or

More information

Directory chapter 05. D-Sub Filter subminiature D connectors, 2.54 mm pitch

Directory chapter 05. D-Sub Filter subminiature D connectors, 2.54 mm pitch F Directory chapter 05 D-Sub Filter subminiature D connectors, 2.54 mm pitch New Page General information.............................................. 05.02 Technical characteristics..........................................

More information

Thread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm

Thread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm Long Distance Cylindrical. Extra long for increased protection and sensing performance triple proximity sensors for flush mounting requirements. designed and tested for extra long life. Ordering Information

More information

Honeywell Model 700/800 Signal Processor and Viewing Head

Honeywell Model 700/800 Signal Processor and Viewing Head Honeywell Model 700/800 Signal Processor and Viewing Head USER MANUAL Model 700ACSP Universal 85-265 VAC powered, plus 24VDC backup. Model 700DCSP 22-26VDC powered, plus 24VDC backup. The two Model 700

More information

M12 Field Wireable Connectors. M12 CAT.6A Field Wireable Connectors. M12 Field Wireable Connectors for PROFINET

M12 Field Wireable Connectors. M12 CAT.6A Field Wireable Connectors. M12 Field Wireable Connectors for PROFINET M12 Connectors Application Advantage Shielded design ETHERLINE Ethernet Cable, Connectors & Tools M12 Field Wireable Connectors Male Female Temperature Range: Max. 85 C Nominal Voltage: Nominal Current:

More information

SINETAMER. ESPECIFIACIONES EQUIPOS COMERCIALIZADOS POR EDC SUPPLY y RESPALDADOS POR EDCEECA EN VENEZUELA

SINETAMER. ESPECIFIACIONES EQUIPOS COMERCIALIZADOS POR EDC SUPPLY y RESPALDADOS POR EDCEECA EN VENEZUELA SINETAMER. ESPECIFIACIONES EQUIPOS COMERCIALIZADOS POR EDC SUPPLY y RESPALDADOS POR EDCEECA EN VENEZUELA SUPRESOR PRINCIPAL DE 300 KA. ST-SMLA 3N4 TRANSIENT VOLTAGE SURGE SUPPRESSORS. PROTECTION AGAINST

More information

M-Line Series MN Multi-Pin Plugs and Receptacles Vac, Vdc

M-Line Series MN Multi-Pin Plugs and Receptacles Vac, Vdc Applications Designed for the roughest industrial applications, providing reliable, rugged service for power, control and instrumentation. For use in the roughest industrial applications, ranging from:

More information

Brad Nano-Change M8 Sensor/Actuator Connectivity

Brad Nano-Change M8 Sensor/Actuator Connectivity Brad Nano-Change M8 Brad Nano-Change M8 connectivity provides a rugged and space-saving solution to wire a wide range of sensors and actuators from proximity switches to rotary encoders in harsh environments.

More information

FB-6SP and FB-12SP. Block device couplers. Data sheet 3177_en_A. 2 Features. 1 Description

FB-6SP and FB-12SP. Block device couplers. Data sheet 3177_en_A. 2 Features. 1 Description Block device couplers Data sheet 3177_en_A 1 Description PHOENX CONTACT 2015-01-20 2 Features The and block couplers provide an interface between the fieldbus trunk cable and field devices on Foundation

More information

BUS UNITRONIC BUS DeviceNet Gray

BUS UNITRONIC BUS DeviceNet Gray BUS UNITRONIC BUS DeviceNet Gray For DeviceNet bus systems; stationary applications; UNITRONIC UNITRONIC DeviceNet THIN UNITRONIC BUS DeviceNet cables provide reliable data and power transfer between industrial

More information

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882 1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882 This manual is intended for use in support of installation, commissioning and configuration of the 1/32-DIN Temperature

More information

New Product Bulletin. Lumberg Automation EtherNet/IP Modules for Industrial Automation Applications

New Product Bulletin. Lumberg Automation EtherNet/IP Modules for Industrial Automation Applications New Product Bulletin PB 327 Lumberg Automation EtherNet/IP Modules for Industrial Automation Applications These 16 digital I/O channels with universal input/output functionality for direct connections

More information

0.703 dia. [17.86] Cord Connector Contact Arrangements Shown from rear of connector DIMENSIONS ARE FOR REFERENCE ONLY

0.703 dia. [17.86] Cord Connector Contact Arrangements Shown from rear of connector DIMENSIONS ARE FOR REFERENCE ONLY ONLINE CATALOG SWITCHCRAFT, INC. N. Elston Ave. Chicago, IL 00 77 79-700 FAX: 77 79-19 www.switchcraft.com EN MINI WEATHERTIGHT CONNECTOR SERIES EN CORD CONNECTOR 1.8 [9.8] 0. REF 0.70 dia. [17.8] PIN

More information

P522 Signal Processor

P522 Signal Processor P522 Signal Processor INSTALLATI INSTRUCTIS Self-Check Contact Ratings: Max switching power - 60 W 125Vac Max switching voltage - 220VDC, 250Vac Max switching current - 2A DC, AC Analog Flame Signal: User

More information

Controller Area Networks

Controller Area Networks Controller Area Networks Contents CAN Overview PG 44 ISO Box and 9-pin Diagnostic PG 45 J1939/11 Schematics PG 46 J1939/15 Schematics PG 47 43 CAN Overview Controller Area Networks, or CAN are multiplex

More information

5 Fieldbus Technology

5 Fieldbus Technology 5 Fieldbus Technology Ex e / Ex i 10922E00 The s Ex e/ex i connect intrinsically safe Foundation Fieldbus H1 or Profibus PA field devices to a non-intrinsically safe / Ex e trunk. Up to four intrinsically

More information

Discrete I/O 12 Discrete Inputs 8 Relay Outputs CANopen P/N: AXDIO128CO

Discrete I/O 12 Discrete Inputs 8 Relay Outputs CANopen P/N: AXDIO128CO Description: The Discrete I/O Module reads 12 discrete inputs and sets 8 Form C relay outputs while providing a simple interface between a CANopen network and other electronic devices on a machine. The

More information

Ethernet Media. Technical Data. Bulletin Numbers 1585, 1585A, 1585BP, 1585BT, 1585BX, 1585BZ, 1585D, 1585J

Ethernet Media. Technical Data. Bulletin Numbers 1585, 1585A, 1585BP, 1585BT, 1585BX, 1585BZ, 1585D, 1585J Technical Data Ethernet Media Bulletin Numbers 585, 585A, 585BP, 585BT, 585BX, 585BZ, 585D, 585J Topic Page Summary of Changes Introduction Cable Spools Unshielded Twisted Pair Shielded Twisted Pair (Foil

More information

DeviceNet Media System

DeviceNet Media System System Table of Contents General Information Quick Selection Guide...6-...6- Flat System KwikLink Lite...6-6 Cable Spools...6-7 Trunk-Line Connector, Drop-Line Connector, and Flat to Thin Round Converter,

More information

HARTING. Interface Connectors. People Power Partnership

HARTING. Interface Connectors. People Power Partnership 11 5 HARTING Interface Connectors People Power Partnership Directory chapter 00 Modular metric high speed connectors, 2.0 mm pitch Page connector system general information......................... 00.04

More information

Specifications. Description. Degree of Protection. Input Voltage (Relay type) Input Voltage (Solid-State type) Electrical Design Life (Relay type)

Specifications. Description. Degree of Protection. Input Voltage (Relay type) Input Voltage (Solid-State type) Electrical Design Life (Relay type) General Principles 9-10-Safety Logic Power General Purpose 800Z-GF2Q5 Heavy Industrial 800Z-HF1 General Purpose 800Z-GL3Q5B Heavy Industrial 800Z-HL1Y Bulletin 800Z Zero-Force are designed for use by machine

More information

EFP SERIES FLAMEPROOF ELECTRICAL CONNECTORS FOR HAZARDOUS ENVIRONMENTS

EFP SERIES FLAMEPROOF ELECTRICAL CONNECTORS FOR HAZARDOUS ENVIRONMENTS EFP SERIES FLAMEPROOF ELECTRICAL CONNECTORS FOR HAZARDOUS ENVIRONMENTS Table of Contents EFP Introduction 4 Connector Features 5-7 Code Logic 8 Inline Plug w Threaded Entry Metric 9 Inline Plug w Mechanical

More information

Standard Buccaneer - Ethernet

Standard Buccaneer - Ethernet IP6 rated IP69K, Tested in accordance with DIN 40050/Part 9 IP6k9k or compliant PUR / PVC jacket on cable Shielded system or shielded coupler Shroud on RJ45 Screw coupling Rewireable flex connector PCB

More information

CROWN LINE Power Bus Bar Distribution System

CROWN LINE Power Bus Bar Distribution System COWN LINE Power Bus Bar Distribution System COWN LINE Power Bus Bar Distribution System The pluggable bus bar system Currents up to 300 Amps Up to 2 meters in length Pluggable breakers VDE finger proof

More information

DeviceNet Physical Media

DeviceNet Physical Media DeviceNet Physical Media Round Media Round trunk cable is available in bulk spools or as pre-molded cordsets or patchcords in varying lengths. A wide variety of rugged, durable DeviceNet components is

More information