1 Haas Technical Documentation Wireless Intuitive Probe System - WIPS - Troubleshooting Guide Scan code to get the latest version of this document Translation Available Basics of WIPS 1. OMP40-2 work probe: A spindle-mounted wireless probe that communicates with an optical interface. 2. Work probe stylus: The part of the work probe that touches parts during measurement. 3. Tool probe stylus: The part of the tool probe that tools touch during measurement. Tools touch the top and side of the stylus when the probe measures tool length and diameter. 4. OTS tool probe: The OTS is a battery-powered, wireless probe. 5. OMI-2H Optical Machine Interface:The wireless interface for the OMP40-2 work probe. The OMI-2H uses infrared light to communicate with the CNC control and switch the probe on or off. 6. OMI cable: This cable connects the OMI to the CNC control. Work probes for Wireless Intuitive Probe System (WIPS) do not work in the wired probe systems (VQCPS). The work probes can be differentiated by: 1. The VQCPS work probe (P/N ) has a square Haas logo. 2. The WIPS work probe (P/N ) has a round Haas logo. For installation instructions for both the work probe and tool probe refer to: Wireless Intuitive Probe System (WIPS) - Installation Powering on the Work Probe and Tool Probe: Probe Operation: Power on the Work Probe Power on the Tool Probe Copyright 2018 by Haas Automation, Inc. No unauthorized reproduction Last Published On January 02, /11

2 Probe Operation: Power on the Work Probe Power on the Tool Probe M59 P1133; Classic Haas Control (CHC) M59 P1134; G04 P1.0; Push [CYCLE START]. M59 P1134; Push [CYCLE START]. M59 P2; Next Generation Contol (NGC) M59 P3; G04 P1.0; Push [CYCLE START]. M59 P3; Push [CYCLE START]. Copyright 2018 by Haas Automation, Inc. No unauthorized reproduction Last Published On January 02, /11

3 Probe Operation: Power on the Work Probe Power on the Tool Probe The LEDs on the work probe flash green when the probe is powered on and ready for use. When the probe stylus is touched, a beep sound is made by the CNC control. The LEDs on the work probe flash red each time the stylus is touched. When the stylus on the tool probe is touched, the CNC control makes a "beep" sound. The tool probe does not have any LEDs. Troubleshooting Symptoms: Symptom Possible Cause Corrective Action Alarm 1101 PROBE STARTUP FAILURE. Alarm 1092 PROBE OPEN. Alarm 1093 PROBE FAIL. Incorrect measurements. The probe does not give repeatable location results. Bad batteries. The settings in the work probe are not correct. Interference from the work lights. The settings in the work probe are not correct. The surface of the part was not found. The probe is not calibrated. The probe stylus is loose. The probe stylus is not concentric to the spindle centerline (runout). The WIPS programs or macro variables are corrupted. Replace the batteries. Correct the settings. Adjust the work lights. Correct the settings. Edit the program. Calibrate the probe. Check the probe stylus. Adjust the probe stylus to eliminate runout. Load the latest Renishaw macro programs. Make sure to overwrite the current macro programs. Batteries Corrective Action: Battery replacement is always the first step in probe troubleshooting. Replace both batteries at the same time. Test the batteries before you install them. The batteries in the probes have a life span of about (8) months, and must be replaced regularly. If the batteries are low, the work probe's green and blue LEDs may flash. If the batteries are completely dead, the red LED may constantly be on. Do not rely on a multimeter for testing the batteries. The lithium batteries in the probe may read 3.6 Volts from a multimeter, even though they are low. Write the date on newly installed batteries for future reference. Note: Do not touch the stylus during battery replacement. If the stylus is touched, the probe may power on in the setting mode. Settings can be accidentally changed in this mode. Interference Copyright 2018 by Haas Automation, Inc. No unauthorized reproduction Last Published On January 02, /11

4 Interference Corrective Action: Turn the work lights off to begin troubleshooting. Make sure the work lights inside the machine are not aimed at the probe or the OMI-2H. Bright lights can interfere with the work probe. Make sure no bright lights are aimed at the machine. Surface Not Found Corrective Action: Edit the program to start the probe closer to the part. Copyright 2018 by Haas Automation, Inc. No unauthorized reproduction Last Published On January 02, /11

5 Calibration Corrective Action: The probes need to be calibrated any time a stylus has been replaced, the tool probe has been moved, or if the CNC control generates alarms during probe routines. Follow the procedure to calibrate the tool probe and the work probe. Refer to: CHC: Wireless Intuitive Probe System (WIPS) - Calibration. NGC: Next Generation Control - Probe Calibration (VPS) The probes must be calibrated in this order: 1. Tool probe 2. Work probe length 3. Work probe diameter OMP 40-2 Work Probe Settings Probe Settings Basics The probe settings are in these (4) groups: 1. Switch-Off Method 2. Enhanced Trigger Filter 3. Optical Transmission Method/Probe Identification 4. Optical Power The sequence that probe flashes tells you the current probe settings. Note: The LEDs flash in different colors and different lengths of time. The sequence that the LED flashes tells you the probe settings. The LEDs flashes a short or a long time. In the tables that follow, a small colored circle shows that the LED flashes a short time. A rectangle shows that the LED flashes a long time. To see what the current probe settings are, do the following: Remove the batteries from the probe for a minimum of 5 seconds. Install the batteries. Important: Do not touch the probe stylus after re-inserting batteries - this is how probe settings are changed. Only touch it later if necessary to change the settings. After you replace the batteries, the probe LED flashes in a specific sequence. Look at the probe LEDs. Record the sequence that the LED flashes. Refer to Renishaw - Probe - OMP Settings for the meaning of the sequence. If you would like to change the probe settings, do the following: Copyright 2018 by Haas Automation, Inc. No unauthorized reproduction Last Published On January 02, /11

6 Remove the batteries [1] from the probe for a minimum of 5 seconds. Move and hold the stylus [2] while installing the batteries. Hold the stylus until the probe completes the LED sequence [3] and flashes Red 5 times. Release the stylus. To change the probe settings you move the stylus in a specified order, refer to the tables below for the orders for different settings: Copyright 2018 by Haas Automation, Inc. No unauthorized reproduction Last Published On January 02, /11

7 The Illustration shows these symbols: The symbols tells you this: This gives this result: A red arrow that points to the right. Move and hold the stylus for less than (4) seconds. Selects the next option within a group. A green arrow that points down. A white arrow that points down. Move and hold the stylus for more than (4) seconds. Do not touch the stylus for (20) seconds or more. Moves from one group to another. Exits the set up. Default OMP40-2 settings are the following: Switch Off Method: Optical Off Enhanced Trigger Filter: Trigger Filter Off Optical Transmission Method/Probe Identification: Modulate Probe 1 Optical Power: Low OMP Macro Variables. 556: (XRAD) Stylus X calibration radius 557: (YRAD) Stylus Y calibration radius 558: (XOFF) X axis stylus offset (run out) 559: (YOFF) Y axis stylus offset (run out) 560: Tool number for the OMP40-2 probe OTS Tool Probe Settings OTS Settings Basics: Copyright 2018 by Haas Automation, Inc. No unauthorized reproduction Last Published On January 02, /11

8 The probe settings are in these (3) groups. 1. Enhanced Trigger Filter 2. Probe Identification 3. Optical Power The LEDs flash in different colors and different lengths of time. The sequence that the LED flashes tells you the probe settings. The LEDs flash a short or a long time. In the tables that follow, a small colored circle shows that the LED flashes a short time. A colored rectangle shows that the LED flashes a long time. To find the current OTS probe settings do the following: Remove and re-install the batteries. After you install the batteries, the probe LED flashes in a special sequence. These LEDs should show the initial factory settings. Note: Do not touch the probe when installing the batteries, this could alter the probe settings. Look at the probe LEDs. Record the sequence of color and length of time that the LED flashes Refer to Renishaw - Probe - OTS - Settings for light sequence meanings. To change the OTS probe settings do the following: Copyright 2018 by Haas Automation, Inc. No unauthorized reproduction Last Published On January 02, /11

9 Remove the batteries [1] from the probe for a minimum of 5 seconds. Move and hold the stylus [2] while installing the batteries. Hold the stylus until the probe completes the LED sequence [3] and flashes Red 5 times. Release the stylus. Follow the below tables to select the values you want for the settings. Default factory settings are shown in the next set of tables: Copyright 2018 by Haas Automation, Inc. No unauthorized reproduction Last Published On January 02, /11

10 The Illustration shows these symbols: The symbols tells you this: This gives this result: A red arrow that points to the right. Move and hold the stylus for less than (4) seconds. Selects the next option within a group. A green arrow that points down. Move and hold the stylus for more than (4) seconds. Moves from one group to another. A white arrow that points down. Default probe settings are the following: Do not touch the stylus for (20) seconds or more. Exits the set up. The default probe settings for these (3) groups are: Enhanced Trigger Filter is set to Off [1]. Probe Identification is set to Probe 2 [2]. Optical Power is set to Low [3]. OTS Macro Variables 582: OTS stylus Z location, non rotating tools 583: OTS stylus Z locations, rotating tools 584: Stylus size for diameter setting 585: X-Axis stylus center location 586: Y-Axis stylus center location 587: Z approach position (This is used in length and diameter probing only). The first fast positioning move to the position where the tool offset is applied (height above stylus). 588: Z clearance position (This is used in length and diameter probing only). The position above the stylus for clearance moves around the stylus (height above stylus). 589: Tools above this diameter rotate (This is used in length and diameter probing only) 590: Maximum cutter diameter size (This is used in length and diameter probing only) 592: Probe orientation. This defines the diameter measuring axis, and the radius offsetting direction for rotating length setting. Copyright 2018 by Haas Automation, Inc. No unauthorized reproduction Last Published On January 02, /11

11 OMI-2H Operation: 1. START SIGNAL (yellow): This LED flashes for one second when the OMI-2H sends a start signal to switch on or switch off the work probe or the tool probe. 2. LOW BATTERY (red): If the OMI-2H detects a low battery from one of the probes, the low battery LED is on. Replace the batteries in the probes. 3. PROBE STATUS (green,red): This bi-color LED is green when the probe is powered on, and red when the probe is triggered. 4. ERROR (red, blue, yellow): Tri-color LED indicates a weak or lost signal from the probe. Red indicates the probe has failed or switched off. Blue indicates a signal from a second probe is being received. Yellow indicates that a weak signal is received. The probe signal could be blocked from a fixture or rotary table. 5. SIGNAL CONDITION (red, blue, yellow): This tri-colored LED indicates the strength of the signal from the probes. Red indicates no signal from the probe. Yellow indicates a weak signal. Green indicates a good signal. 6. ACTIVE PROBE (green): There are (2) LEDs that show which probe is currently active. For more information refer to Optical Machine Interface (OMI) - Lights Information. Copyright 2018 by Haas Automation, Inc. No unauthorized reproduction Last Published On January 02, /11

Use a Probe to Measure a Work Offset Again Before a High-Precision Part

Use a Probe to Measure a Work Offset Again Before a High-Precision Part Haas Technical Documentation Use a Probe to Measure a Work Offset Again Before a High-Precision Part Scan code to get the latest version of this document Translation Available Known and Unknown WIPS Tasks

More information

OTS optical tool setter (AA version)

OTS optical tool setter (AA version) Data sheet H-5514-8205-01-A OTS optical tool setter (AA version) www.renishaw.com/ots The cableless OTS with optical signal transmission allows unrestricted machine motion and ease of installation on CNC

More information

Ballbar QC20-W - Analysis

Ballbar QC20-W - Analysis Haas Technical Documentation Ballbar QC20-W - Analysis Applies to machines built from: January, 2016 Scan code to get the latest version of this document Translation Available Ballbar QC20-W - Analysis

More information

Vector Drive - Troubleshooting Guide

Vector Drive - Troubleshooting Guide Haas Technical Documentation Vector Drive - Troubleshooting Guide Scan code to get the latest version of this document Translation Available The Haas Vector drive is the source of power for the spindle

More information

I/O PCB-AC - Replacement

I/O PCB-AC - Replacement Haas Technical Documentation I/O PCB-AC - Replacement AD0007 Rev G Applies to machines built from: January, 1999 Scan code to get the latest version of this document Translation Available Electrical Cabinet

More information

Vector Drive - Troubleshooting Guide

Vector Drive - Troubleshooting Guide Haas Technical Documentation Vector Drive - Troubleshooting Guide Scan code to get the latest version of this document Translation Available The Haas Vector drive is the source of power for the spindle

More information

Next Generation Control - Robot Integration Aid

Next Generation Control - Robot Integration Aid Haas Technical Documentation Next Generation Control - Robot Integration Aid Scan code to get the latest version of this document Translation Available INTRODUCTION This document is intended to aid in

More information

OMP optical machine probe

OMP optical machine probe Data sheet H-4071-8200-01-A - optical machine probe www.renishaw.com/omp40-2 The compact for CNC machining centres reduces set up times Critical part dimensions are measured and offsets updated to reduce

More information

G47 Text Engraving (Group 00) - Mill. Troubleshooting. How it Works. Haas Technical Documentation. Setting 85 is Too High for Shallow Text Engraving

G47 Text Engraving (Group 00) - Mill. Troubleshooting. How it Works. Haas Technical Documentation. Setting 85 is Too High for Shallow Text Engraving Haas Technical Documentation G47 Text Engraving (Group 00) - Mill Scan code to get the latest version of this document Translation Available Troubleshooting Setting 85 is Too High for Shallow Text Engraving

More information

OMP40-2 optical machine probe

OMP40-2 optical machine probe Data sheet H-4071-8200-03-A optical machine probe www.renishaw.com/omp40-2 The is a compact 3D touch trigger inspection probe with optical signal transmission, used for workpiece set up and inspection

More information

OMP60 - optical machine probe

OMP60 - optical machine probe Data sheet H-2000-2131-03-B OMP60 - optical machine probe www.renishaw.com/omp60 OMP60 probe Optical centre line 9 MI 12 interface unit or MI 12 board OMM OMI / OMI-2 Workpiece Stylus PSU3 power supply

More information

OMP60 - optical machine probe

OMP60 - optical machine probe Data sheet H-2000-2131-02-A OMP60 - optical machine probe The probe transmits through 3 for ease of operation on a vertical or horizontal CNC machining centre. OMP60 probe Optical centre line 9 MI 12 interface

More information

Vector Drive - Troubleshooting Guide

Vector Drive - Troubleshooting Guide Haas Technical Documentation Vector Drive - Troubleshooting Guide Scan code to get the latest version of this document Translation Available The Haas Vector drive is the source of power for the spindle

More information

FSIR-100. User Guide. Wireless IR Commissioning Tool CONTENTS USING THE FSIR-100 COMMISSIONING TOOL BATTERIES

FSIR-100. User Guide. Wireless IR Commissioning Tool CONTENTS USING THE FSIR-100 COMMISSIONING TOOL BATTERIES FSIR-100 Wireless IR Commissioning Tool User Guide CONTENTS Using The FSIR-100 Commissioning Tool... 1 Batteries... 1 Navigation... 2... 2 IR Communication... 2 Screens... 3 Home Menu...3...3...5...5 s...6

More information

WIPS. Operator s Manual Supplement A Revision B December 2018 English Original Instructions

WIPS. Operator s Manual Supplement A Revision B December 2018 English Original Instructions , WIPS Operator s Manual Supplement 96-10002A Revision B December 2018 English Original Instructions Haas Automation Inc. 2800 Sturgis Road Oxnard, CA 93030-8933 U.S.A. HaasCNC.com 2018 Haas Automation,

More information

Digital display for EMCO milling machines

Digital display for EMCO milling machines Digital display for EMCO milling machines Input box 7 8 9 1 X Y Z HELP 4 5 6 1 2 3 0. - ESC 3 CE ENT R + R - 2 REF RST 1... Screen (working window, displays) 2... 5 soft keys (function depends on the respective

More information

527F CNC. Retrofit controller for machines made by Fadal Machining Centers. Installation and set-up manual Calmotion LLC

527F CNC. Retrofit controller for machines made by Fadal Machining Centers. Installation and set-up manual Calmotion LLC 527F CNC Retrofit controller for machines made by Fadal Machining Centers Installation and set-up manual 2008-2018 Calmotion LLC Calmotion LLC 7536 San Fernando Road Sun Valley, CA 91352 www.calmotion.com

More information

QC20-W wireless ballbar system description and specifications

QC20-W wireless ballbar system description and specifications QC20-W wireless ballbar system QC20-W wireless ballbar system description and specifications Hardware Software QC20-W ballbar and ballbar kit QC20-W ballbar The QC20-W ballbar contains a precision linear

More information

Hardinge 5C Gear-Driven Indexer

Hardinge 5C Gear-Driven Indexer Indexer/Rotary Hardinge 5C Gear-Driven Indexer Quotation To: Budgetary Quote Prices Valid for 30 Days Your Hardinge Representative: Al Comstock 607.378.4044 al.comstock@hardinge.com Hardinge Inc. One Hardinge

More information

H C Technical specifications. Probing systems for CNC machine tools

H C Technical specifications. Probing systems for CNC machine tools H-2000-3020-07-C Technical specifications Probing systems for CNC machine tools Introduction The invention of the touch trigger probe in the early 1970s revolutionised the development of the CMM (co-ordinate

More information

RF Remote Control Kit

RF Remote Control Kit RF Remote Control Kit The Rock-Ola RF Remote control operates via radio and therefore does not need to see the jukebox or even be in the same room. There are over 1000 channels available for reliable operation.

More information

3D measurement solutions

3D measurement solutions 3D measurement solutions The Earth was never fl at......nor 2 Dimensional! A fl at Earth was widely accepted as fact by many ancient civilizations. In the 4th Century BC Aristotle was one of the fi rst

More information

E3 CNC Router Troubleshooting Guide

E3 CNC Router Troubleshooting Guide Simple Cost Effective Designs. E3 CNC Router Troubleshooting Guide The purpose of this document is to give those new to CNC routing is a quick reference for the common issues of getting the E3 CNC router

More information

Section 15: Touch Probes

Section 15: Touch Probes Touch Probes Touch Probe - Length Offset The tool setting probe is used with the UTILITY command to establish the length offset. It can also be used for tool breakage detection and setting tool diameter

More information

Other features of parametric programming

Other features of parametric programming Other features of parametric programming As you have seen, this chapter has been working from common CNC features toward the less popular In this discussion, we simply mention CNC features that are equipped

More information

Introduction. Prerequisites. Ballbar - QC20-W - Analysis LAST UPDATED: 12/01/2018

Introduction. Prerequisites. Ballbar - QC20-W - Analysis LAST UPDATED: 12/01/2018 Ballbar - QC20-W - Analysis LAST UPDATED: 12/01/2018 Ballbar - QC20-W - Analysis Introduction This procedure tells you how to do a Renishaw QC20-W ballbar analysis. The QC20-W BallBar uses a Bluetooth

More information

Maincon Control Software (Mill VER18 and Lathe VER11) - Load

Maincon Control Software (Mill VER18 and Lathe VER11) - Load Maincon Control Software (Mill VER18 and Lathe VER11) - Load LAST UPDATED: 09/20/2018 Introduction This procedure tells you how to do these tasks on any CNC machine with a Maincon PCB: Install a new Maincon

More information

LPWWS Smart Wi-Fi Wall Station

LPWWS Smart Wi-Fi Wall Station Manufactured by: GTO Access Systems, LLC (844) 256-3130 www.gtoaccess.com LPWWS Smart Wi-Fi Wall Station Programming / Installation Instructions This Wall Station allows operation of the light and door

More information

Calibration and setup of part probe

Calibration and setup of part probe Calibration and setup of part probe Fundamentals To measure workpiece dimensions, an electronic touchtrigger probe is required that provides a signal change (edge) when deflected with the required repeat

More information

527F CNC. Retrofit controller for machines made by Fadal Machining Centers. Installation and set-up manual Calmotion LLC

527F CNC. Retrofit controller for machines made by Fadal Machining Centers. Installation and set-up manual Calmotion LLC 527F CNC Retrofit controller for machines made by Fadal Machining Centers Installation and set-up manual 2008-2018 Calmotion LLC Calmotion LLC 7536 San Fernando Road Sun Valley, CA 91352 www.calmotion.com

More information

AbraScan Test Strip Reader Digital Reading of Test Strips for the Determination of Cyanotoxins in Contaminated Water Samples

AbraScan Test Strip Reader Digital Reading of Test Strips for the Determination of Cyanotoxins in Contaminated Water Samples AbraScan Test Strip Reader Digital Reading of Test Strips for the Determination of Cyanotoxins in Contaminated Water Samples Product No. 475025 1. General Description The AbraScan RDS-1500 Test Strip Reader

More information

USER INSTRUCTION MANUAL FOR LOADCELL TRANSMITTER MODEL TDC/I/0550 (SOFTWARE: VER2A) INDEX

USER INSTRUCTION MANUAL FOR LOADCELL TRANSMITTER MODEL TDC/I/0550 (SOFTWARE: VER2A) INDEX USER INSTRUCTION MANUAL FOR LOADCELL TRANSMITTER MODEL TDC/I/0550 (SOFTWARE: VER2A) INDEX DOCUMENT NO: TDC 0550 MANUAL - 2 1.0) INTRODUCTION. PAGE 2 1.1) ABOUT THIS MANUAL. PAGE 2 1.2) INTRODUCTION. PAGE

More information

EZ-SPKDVR Covert Speaker Digital Video Recorder

EZ-SPKDVR Covert Speaker Digital Video Recorder EZ-SPKDVR Covert Speaker Digital Video Recorder Product Description The EZ-SPKDVR is a covert hidden video recording system mounted within a set of fullyfunctional PC Speakers. This revolutionary system

More information

The WoBLR, World's Best Level for RVs RVIQ WoBLR App: Instructions

The WoBLR, World's Best Level for RVs RVIQ WoBLR App: Instructions The WoBLR, World's Best Level for RVs RVIQ WoBLR App: Instructions Thank you for choosing the WoBLR Remote RV Level from RV Intelligence. The RVIQ WoBLR App is designed to operate from both Android and

More information

Profile Modeler Profile Modeler ( A SuperControl Product )

Profile Modeler Profile Modeler ( A SuperControl Product ) Profile Modeler ( A SuperControl Product ) - 1 - Index Overview... 3 Terminology... 3 Launching the Application... 4 File Menu... 4 Loading a File:... 4 To Load Multiple Files:... 4 Clearing Loaded Files:...

More information

IXIAN. Reads. Range / Accuracy. Calibration. 1, 2, 3 point remotely through PLC or directly on board.

IXIAN. Reads. Range / Accuracy. Calibration. 1, 2, 3 point remotely through PLC or directly on board. V 3.0 Revised 12/13/17 ph IXIAN Transmitter Reads ph Range.001 14.000 Accuracy Calibration Supported probes Temp probe +/ 0.002 1, 2, 3 point remotely through PLC or directly on board Any type & brand

More information

I/O PCB-R - Replacement

I/O PCB-R - Replacement Haas Technical Documentation I/O PCB-R - Replacement AD0008 Rev H Applies to machines built from: January, 1996 to January, 1999 Scan code to get the latest version of this document Translation Available

More information

ProHome IPC App. Operating Manual. easy to operate using the "ProHomeIPC" app from Olympia en

ProHome IPC App. Operating Manual. easy to operate using the ProHomeIPC app from Olympia en ProHome IPC App easy to operate using the "ProHomeIPC" app from Olympia Operating Manual 11.2016 en General Information... 5 Installing the ProHomeIPC App... 5 Connecting the Smartphone/Tablet PC to the

More information

TV WIRELESS HEADPHONES

TV WIRELESS HEADPHONES TV WIRELESS HEADPHONES Item No. 206077 Owner s Manual Thank you for purchasing the Sharper Image TV Wireless Headphones. This updated version has a new design with new features, including a digital audio

More information

AV300 VIDEO MEASURING SYSTEM.

AV300 VIDEO MEASURING SYSTEM. VIDEO MEASURING SYSTEM www.starrett-precision.co.uk Starrett - Total Solution Provider With Starrett Metrology products, the system is only a part of the whole package. From application analysis, system

More information

Installation and user s guide H A OMP40

Installation and user s guide H A OMP40 Installation and user s guide H-2000-5022-05-A OMP40 2001-2006 Renishaw. All rights reserved. This document may not be copied or reproduced in whole or in part, or transferred to any other media or language,

More information

用户手册. KT-LCD6 ebike Special Meter

用户手册. KT-LCD6 ebike Special Meter 用户手册 User Manual KT-LCD6 ebike Special Meter WWW.SZKTDZ.COM Contents Preface... 4 Outlook and Size... 4 Meter Dimension 4 Button Box Dimension.. 4 Main Material and Color.... 5 Wiring Schematic.. 5 Installation

More information

H C Technical specifications. Probing systems for CNC machine tools

H C Technical specifications. Probing systems for CNC machine tools H-2000-3020-08-C Technical specifications Probing systems for CNC machine tools Introduction The invention of the touch trigger probe in the early 1970s revolutionised the development of the CMM (co-ordinate

More information

Next Generation Control - Wireless Network

Next Generation Control - Wireless Network Haas Technical Documentation Next Generation Control - Wireless Network Scan code to get the latest version of this document Translation Available Networking Terms and Responsibilities Networks and operating

More information

Robolab. Table of Contents. St. Mary s School, Panama. Robotics. Ch. 5: Robolab, by: Ernesto E. Angulo J.

Robolab. Table of Contents. St. Mary s School, Panama. Robotics. Ch. 5: Robolab, by: Ernesto E. Angulo J. Robolab 5 Table of Contents Objectives...2 Starting the program...2 Programming...3 Downloading...8 Tools...9 Icons...9 Loops and jumps...11 Multiple tasks...12 Timers...12 Variables...14 Sensors...15

More information

User Manual. Universal CMM Server

User Manual. Universal CMM Server Universal CMM Server 6/5/2016 1. GUI..... 3 1.1. Main screen... 3 1.1.1. Tabs... 4 1.1.1.1. Command... 4 1.1.1.2. Tools... 5 1.1.1.3. Tool Properties... 7 1.1.1.4. Errors tab... 7 1.1.2. Right pane...

More information

Linear, and segmented over up to 1000 points Squareness calibration Matrix compensation over up to 30 x 30 points

Linear, and segmented over up to 1000 points Squareness calibration Matrix compensation over up to 30 x 30 points ND 1404 Axes Encoder inputs* 4 (XYZQ)» 1 V PP or «TTL (other interfaces upon request) Subdivision factor* 10-fold (only for 1 V PP ) Display step 1) Display Functions Error compensation Data interface

More information

Calibration and setup of a tool probe

Calibration and setup of a tool probe Calibration and setup of a tool probe Fundamentals Tool-setting is the process of determining geometric information length, radius and / or diameter of a cutting tool using a tool-setting device. Some

More information

Measuring on Machine Tools Probing Systems and Software

Measuring on Machine Tools Probing Systems and Software Measuring on Machine Tools Probing Systems and Software Your Solution Partner in Machine Tool Probing m&h designs and manufactures precision made, highquality, dependable probe systems for use in machine

More information

Geomet operates in four different levels designed to match your inspection needs. These levels are known as:

Geomet operates in four different levels designed to match your inspection needs. These levels are known as: Helmel Engineering Products, Inc. 6520 Lockport Road Niagara Falls, NY 14305 (800) BEST-CMM (716) 297-8644 (716) 297-9405 fax www.helmel.com www.geomet-cmm-software.com Geomet Version Comparison Chart

More information

2D MANUAL. is a manual 2D vision system with a massive difference.

2D MANUAL. is a manual 2D vision system with a massive difference. vision systems 2D MANUAL is a manual 2D vision system with a massive difference. VuMaster Due to the newly patented Colourmap scale system, the VuMaster does not have a conventional stage or encoders just

More information

Aligning Continuous Casters and Steel Mill Rolls

Aligning Continuous Casters and Steel Mill Rolls Application Notes Aligning Continuous Casters and Steel Mill Rolls System Recommendation Continuous Casters L-740 Ultra-Precision Leveling Laser Steel L-743 Ultra-Precision Triple Scan Alignment System

More information

E3 CNC Router Troubleshooting Guide

E3 CNC Router Troubleshooting Guide Simple Cost Effective Designs. E3 CNC Router Troubleshooting Guide The purpose of this document is to give those new to CNC routing is a quick reference for the common issues of getting the E3 CNC router

More information

Keypad Lock. Operation and Service Manual. Order parts online

Keypad Lock. Operation and Service Manual. Order parts online Keypad Lock Order parts online www.follettice.com Operation and Service Manual 801 Church Lane Easton, PA 18040, USA Toll free (800) 523-9361 (610) 252-7301 Fax (610) 250-0696 www.follettice.com 00163345R00

More information

This presentation is NOT designed to replace the Hofmann installation instruction manual. This presentation is only a reference to assist in the

This presentation is NOT designed to replace the Hofmann installation instruction manual. This presentation is only a reference to assist in the This presentation is NOT designed to replace the Hofmann installation instruction manual. This presentation is only a reference to assist in the installation Camera Pods are mounted at each end of the

More information

INSTALLATION AND OPERATING INSTRUCTIONS DSST SYSTEM

INSTALLATION AND OPERATING INSTRUCTIONS DSST SYSTEM INSTALLATION AND OPERATING INSTRUCTIONS DSST SYSTEM PROPORTIONAL and NON-PROPORTIONAL TOGGLE SWITCH RADIO REMOTE CONTROL SYSTEM MODEL FHSTP/DSSTP SERIES FHST/DSST SYSTEM DESCRIPTION The DSST Wireless Control

More information

ATC3 Umbrella Tool Changer. Operator s Manual. Rev. 05-October Centroid Corp. Howard, PA 16841

ATC3 Umbrella Tool Changer. Operator s Manual. Rev. 05-October Centroid Corp. Howard, PA 16841 CENTROID ATC3 Umbrella Tool Changer Operator s Manual Rev. 05-October-2007 2006 Centroid Corp. Howard, PA 16841 D:\Documents\Manuals\ATC3\Umbrella ATC3 Operating Instructions.doc Page 1 of 13 D:\Documents\Manuals\ATC3\Umbrella

More information

TOOL MONITORING ADAPTIVE CONTROL

TOOL MONITORING ADAPTIVE CONTROL Y Z X celerometer / Vibration Senso Coolant Flow Spindle Speed Adaptive Control Tool Connect Smart Light Autocomp Micro Sensor Tools Tool Monitoring TOOL MONITORING ADAPTIVE CONTROL I M P R O V E PERFORMANCE

More information

SSII SUV MANUAL. LAGUNA TOOLS 2072 Alton Parkway Irvine, California Ph:

SSII SUV MANUAL. LAGUNA TOOLS 2072 Alton Parkway Irvine, California Ph: SSII SUV MANUAL LAGUNA TOOLS 2072 Alton Parkway Irvine, California 92606 Ph: 800.234.1976 www.lagunatools.com 2018, Laguna Tools, Inc. LAGUNA and the LAGUNA Logo are the registered trademarks of Laguna

More information

User Manual. PCKeypad Wireless Keypad

User Manual. PCKeypad Wireless Keypad User Manual PCKeypad Wireless Keypad Description The PCKeypad is a wireless keypad with a PentaCODE transmitter built-in. It works with all of Elsema s PCR series receivers. The installer has the option

More information

Torque Control Verifier

Torque Control Verifier Torque Control Verifier Instruction Manual Revision 1.2 September 2002 Please Read and Understand Instructions Before Attempting Installation Torque Control Verifier Contents: Quick Start Introduction

More information

Lesson 4 Introduction To Programming Words

Lesson 4 Introduction To Programming Words Lesson 4 Introduction To Programming Words All CNC words include a letter address and a numerical value. The letter address identifies the word type. The numerical value (number) specifies the value of

More information

Custom Rotary Configuration Setup / Rotary File Load - NGC

Custom Rotary Configuration Setup / Rotary File Load - NGC Custom Rotary Configuration Setup / Rotary File Load - NGC LAST UPDATED: 01/18/2019 Introduction This procedure tells you how to set up a custom rotary configuration. Do this procedure to set up a non-haas

More information

Lesson 1: Creating T- Spline Forms. In Samples section of your Data Panel, browse to: Fusion 101 Training > 03 Sculpt > 03_Sculpting_Introduction.

Lesson 1: Creating T- Spline Forms. In Samples section of your Data Panel, browse to: Fusion 101 Training > 03 Sculpt > 03_Sculpting_Introduction. 3.1: Sculpting Sculpting in Fusion 360 allows for the intuitive freeform creation of organic solid bodies and surfaces by leveraging the T- Splines technology. In the Sculpt Workspace, you can rapidly

More information

Narc Box Owners Manual & Warranty Information

Narc Box Owners Manual & Warranty Information Narc Box Owners Manual & Warranty Information 800-445-3640 Brandon@NarcBox.com General Description The Narc Box is a portable narcotic security system designed to keep controlled substances locked and

More information

Quick Start. i16 w16 i8 w8 i6 i4 w4 i2 w2. 25W max. 42W max. Input 24V AC/DC 12/24V AC/DC 12/24V AC/DC 12/24V AC/DC

Quick Start. i16 w16 i8 w8 i6 i4 w4 i2 w2. 25W max. 42W max. Input 24V AC/DC 12/24V AC/DC 12/24V AC/DC 12/24V AC/DC Quick Start Safety Information: White Light and IR Variants (850nm & 940nm) Caution Risk Group 2. Avoid Exposure / use protection. See Safety Information in FULL Instruction Guide for details. Box Contents:

More information

Partizan PAB-FC2. Fingerprint scan time Fingerprint identification time. <0.5 s < % <0.0198% Ingress protection rating

Partizan PAB-FC2. Fingerprint scan time Fingerprint identification time. <0.5 s < % <0.0198% Ingress protection rating 1. Features & Technical Parameters 1.1 Features: Partizan PAB-FC2 Metal vandalproof housing Secure and reliable biometric fingerprint recognition Simple for using, wiring can be done by a user without

More information

RAINWATCH WIRELESS RECEIVER WIRING

RAINWATCH WIRELESS RECEIVER WIRING RAINWATCH INSTALLATION THIS MANUAL IS DESIGNED TO LEAD YOU STEP BY STEP THROUGH THE PROCEDURES REQUIRED TO TEST, INSTALL AND USE YOUR RAINWATCH. BY FOLLOWING THESE PROCEDURES AND SETTING UP THE SYSTEM

More information

AV300 VIDEO MEASURING SYSTEM.

AV300 VIDEO MEASURING SYSTEM. VIDEO MEASURING SYSTEM www.starrett-precision.co.uk 2 Starrett - Total Solution Provider Contents Page With Starrett Metrology products, the system is only a part of the whole package. From application

More information

M7CL StageMix User Guide

M7CL StageMix User Guide Welcome: Thank you for downloading the M7CL StageMix ipad app for the Yamaha M7CL V3 digital mixing console. Via a wireless access point, StageMix can control any variant of M7CL console so long as it

More information

DPS900 SOFTWARE QUICK REFERENCE CARD FOR PILING OPERATORS

DPS900 SOFTWARE QUICK REFERENCE CARD FOR PILING OPERATORS DPS900 SOFTWARE QUICK REFERENCE CARD FOR PILING OPERATORS This document contains information for piling operators on how to use the Trimble DPS900 software. For information for supervisors, please refer

More information

Macro Programming Information

Macro Programming Information Haas Technical Documentation Macro Programming Information Scan code to get the latest version of this document Translation Available Introduction This document tells you how to use macros on the Haas

More information

Installation guide H A. OTS optical tool setter

Installation guide H A. OTS optical tool setter Installation guide H-5514-8504-03-A OTS optical tool setter 2008 2018 Renishaw plc. All rights reserved. This document may not be copied or reproduced in whole or in part, or transferred to any other media

More information

Vision Fitness TF20-TF40-T40 Frame with Classic / Elegant / Touch Console Service Manual

Vision Fitness TF20-TF40-T40 Frame with Classic / Elegant / Touch Console Service Manual Vision Fitness TF20-TF40-T40 Frame with Classic / Elegant / Touch Console Service Manual 1 TABLE OF CONTENTS CHAPTER 1: SERIAL NUMBER LOCATION 1.1 Serial Number Location - TF20 Frame.....3 1.2 Serial Number

More information

LED Dot Matrix Digital Clock. Instructions. Contents. v (5x7-1x6 Module)

LED Dot Matrix Digital Clock. Instructions. Contents. v (5x7-1x6 Module) LED Dot Matrix Digital Clock v1.0.2 (5x7-1x6 Module) Instructions Designer: Yan Zeyuan. China Website: E-mail: yanzeyuan@163.com Contents Attention... 2 Functional Features... 2 Technical Specifications..

More information

Monitor - 15-Inch LCD - Replacement

Monitor - 15-Inch LCD - Replacement Haas Technical Documentation AD0107 Rev F Applies to machines built from: June, 2006 Monitor - 15-Inch LCD - Replacement Scan code to get the latest version of this document Translation Available Monitor

More information

User Manual Wireless Headphone System with Transmitter/Charging Dock HT280

User Manual Wireless Headphone System with Transmitter/Charging Dock HT280 User Manual Wireless Headphone System with Transmitter/Charging Dock HT280 Overview 1 LED indicators 1 Turn on HT280 2 Use HT280 with your TV 2 Check your TVs output options before the set up 2 TVs with

More information

HDS Series Quick Start Guide.

HDS Series Quick Start Guide. Techno-Osai Start Up Sequence HDS Series Quick Turn the Main power switch to the ON Position. 220 volts should have been attached to this switch by an electrician. Power On Button. Computer power ON. The

More information

1 How do I download my PrimeTest 350 to PATGuard 2?... 2 How do I upload my PrimeTest 350 from. 4 How do I upload a logo to my tester for printing?...

1 How do I download my PrimeTest 350 to PATGuard 2?... 2 How do I upload my PrimeTest 350 from. 4 How do I upload a logo to my tester for printing?... Table of Contents Page 1 How do I download my PrimeTest 350 to PATGuard 2?... 2 How do I upload my PrimeTest 350 from PATGuard 2?... 3 How to update the PrimeTest 350 Firmware.... 4 How do I upload a logo

More information

MOVEMENT DETECTOR WITH INBUILT CAMERA USER GUIDE

MOVEMENT DETECTOR WITH INBUILT CAMERA USER GUIDE Easy to install wireless technology MOVEMENT DETECTOR WITH INBUILT CAMERA USER GUIDE www.my-serenity.ch What s in the Box? 1 x Wireless Movement Detector with inbuilt camera (also called PIRCAM or PIR

More information

Brochure. High-accuracy machine tool probes with RENGAGE technology

Brochure. High-accuracy machine tool probes with RENGAGE technology Brochure High-accuracy machine tool probes with RENGAGE technology High-accuracy machine tool probes with RENGAGE technology With unbeatable 3D measurement capability and submicron repeatability, Renishaw

More information

The Nureva Span ideation system. Installation guide. Single panoramic system

The Nureva Span ideation system. Installation guide. Single panoramic system The Nureva Span ideation system Installation guide Single panoramic system Important SAFETY WARNINGS Prior to the installation of this product, the installation instructions should be completely read and

More information

Image Measuring Instrument

Image Measuring Instrument EASY QUICK ACCURATE SAVE Time & Cost Improved efficiency & accuracy L26 All new Image Measuring Instrument Top Series come with new innovative design in structural quality, functionality, and accuracy,

More information

Press the PEN HOME key to move the pen(s) to the outside of the chart. The pen(s) is automatically raised off the chart.

Press the PEN HOME key to move the pen(s) to the outside of the chart. The pen(s) is automatically raised off the chart. DICKSON GETTING STARTED 7-day chart rotation 0 to 100 o F KT8P0/2/3 & KT856 Remote Sensing Temperature Recorder QUICK START 1. Remove the protective pen cap(s). 2. Connect Probe(s): a. KT8P0/2/3: Make

More information

Hi-Res 8 Wi-Fi Digital Picture Frame with MP3 player Table of Contents

Hi-Res 8 Wi-Fi Digital Picture Frame with MP3 player Table of Contents Hi-Res 8 Wi-Fi Digital Picture Frame with MP3 player Table of Contents Before Using the Digital Picture Frame...3 Introduction...3 Features and Specs...3 Package contents...4 Digital Picture Frame Layout...5

More information

ZLog Z6R Altitude Data Recording and Monitoring System

ZLog Z6R Altitude Data Recording and Monitoring System ZLog Z6R Altitude Data Recording and Monitoring System 2014-04-28 Page 1 of 24 Introduction ZLog was designed to provide a lightweight, compact device for measuring and recording altitude over time. It

More information

Prof. Steven S. Saliterman Introductory Medical Device Prototyping

Prof. Steven S. Saliterman Introductory Medical Device Prototyping Introductory Medical Device Prototyping Department of Biomedical Engineering, University of Minnesota http://saliterman.umn.edu/ Images courtesy of Haas You must complete safety instruction before using

More information

THIS IS THE CURRENT FF USER GUIDE AS OF PLEASE DO NOT USE ANY PREVIOUSLY DATED VERSIONS

THIS IS THE CURRENT FF USER GUIDE AS OF PLEASE DO NOT USE ANY PREVIOUSLY DATED VERSIONS THIS IS THE CURRENT FF USER GUIDE AS OF 05-04-2012 PLEASE DO NOT USE ANY PREVIOUSLY DATED VERSIONS INTRODUCTION: I compiled this guide from information posted on RCGroups.COM and from GoodLuckBuy.COM where

More information

USER MANUAL. Turbine Blade Tip-to-Casing Cold Clearance. Wireless Measurement Kit CMS Model

USER MANUAL. Turbine Blade Tip-to-Casing Cold Clearance. Wireless Measurement Kit CMS Model USER MANUAL Turbine Blade Tip-to-Casing Cold Clearance Wireless Measurement Kit Model CMS-3400 PHILTEC 1 www.philtec.com Fiber Optic Sensors for the Measurement of Distance, Displacement and Vibration

More information

High Voltage Power Supply (MMPS) - Troubleshooting Guide

High Voltage Power Supply (MMPS) - Troubleshooting Guide High Voltage Power Supply (MMPS) - Troubleshooting Guide LAST UPDATED: 09/19/2018 High Voltage Power Supply (MMPS) - Troubleshooting Guide Overview The High Voltage Power Supply (MMPS - MINIMILL Power

More information

Quick Start Guide. Cyl-Tel & Tank-Tel Liquid Level Gauges. Designed and Built by: Chart Inc th Street NW New Prague, MN USA (800)

Quick Start Guide. Cyl-Tel & Tank-Tel Liquid Level Gauges. Designed and Built by: Chart Inc th Street NW New Prague, MN USA (800) Quick Start Guide Cyl-Tel & Tank-Tel Liquid Level Gauges Designed and Built by: Chart Inc. 407 7th Street NW New Prague, MN 56071 USA (800) 400-4683 Part Number 20664277 Rev. D 2015 Chart Inc. Quick Start

More information

Modern Robotics Inc. Sensor Documentation

Modern Robotics Inc. Sensor Documentation Sensor Documentation Version 1.0.1 September 9, 2016 Contents 1. Document Control... 3 2. Introduction... 4 3. Three-Wire Analog & Digital Sensors... 5 3.1. Program Control Button (45-2002)... 6 3.2. Optical

More information

Wiring Instructions v3

Wiring Instructions v3 Wiring Instructions v3 Gatekeeper h4.1 Technical Support support@gymmastersoftware.com USA: 415 678 1270 Australia: 03 9111 0323 : 03 974 9169 Copyright 2017 Treshna Enterprises. All rights reserved. Table

More information

[Type text] [Type text] [Type text] GearPro Procedure

[Type text] [Type text] [Type text] GearPro Procedure GearPro Procedure Pictured below is the GearPro main screen. In this manual the icons on the top right corner (Chapter 1), far left side (Chapters 2-5), and far right side (Chapters 6&7) will be discussed.

More information

Mill - DXF and IPS Programming

Mill - DXF and IPS Programming Haas Technical Documentation Mill - DXF and IPS Programming Scan code to get the latest version of this document Translation Available INTRODUCTION AutoCAD DXF (Drawing Interchange Format, or Drawing Exchange

More information

T Series BIOS BIOS SETUP UTILITY

T Series BIOS BIOS SETUP UTILITY BIOS SECTION T4010 LifeBook T Series Tablet PC T Series BIOS BIOS SETUP UTILITY The BIOS Setup Utility is a program that sets up the operating environment for your tablet. Your BIOS is set at the factory

More information

广州谐同电子科技有限公司 Guangzhou Electrony Corporation 用户手册. User Manual. S-LCD3 ebike Special Meter

广州谐同电子科技有限公司 Guangzhou Electrony Corporation 用户手册. User Manual. S-LCD3 ebike Special Meter 广州谐同电子科技有限公司 Guangzhou Electrony Corporation 用户手册 User Manual S-LCD3 ebike Special Meter WWW.ELECTRONY.CN Contents Preface... 4 Outlook and Size... 4 MeterDimension 4 Button Box Dimension.. 4 Main Material

More information

Operating Instructions POSITIP 880

Operating Instructions POSITIP 880 Operating Instructions POSITIP 880 English (en) 12/2008 POSITIP 880 Back View Axis ports Edge finder Ground Power button Parallel port Auxiliary Machine Interface connector Serial port Main power input

More information

Getting to know your Cronus device

Getting to know your Cronus device Getting to know your Cronus device 1. INPUT (USB Receptacle Type A) Connector for wired game controllers or wireless receivers. 2. OUTPUT (USB Plug Type A) To connect the Cronus device on game consoles

More information

MobilePro Users Guide Page 1 of 35. MobilePro HPC. User's Guide. Notices Proprietary Notice and Liability Disclaimer Table of Contents

MobilePro Users Guide Page 1 of 35. MobilePro HPC. User's Guide. Notices Proprietary Notice and Liability Disclaimer Table of Contents MobilePro Users Guide Page 1 of 35 MobilePro HPC User's Guide Notices Proprietary Notice and Liability Disclaimer Table of Contents Notices This device complies with Part 15 of the FCC Rules. Operation

More information