Single Loop Controller YS1000 Series

Size: px
Start display at page:

Download "Single Loop Controller YS1000 Series"

Transcription

1 Single Loop Controller YS Series Single Loop Controller Bulletin B8A-EN

2 Adding value for the customer We are continuing to offer the YS, embodying the quality and reliability we have cultivated over the decades. Incredibly easy to read display TFT LCD makes it even easier to read. Even wider viewing angle (at least. times wider than our previous model) LED back light for brighter performance (at least. times brighter than our previous model) Greater contrast (at least times greater than our previous model) High reliability Dual CPU and manual control ensure high reliability. Improved maintainability Easy to upgrade The Next Evolution of the YS Series Loop Controller 3 Years of Reliable Control! The new YS Series of single-loop controllers is the successor to the Yokogawa YS and YS8 single loop controllers. The YS Series offers improved connectivity with supervisory systems and incorporates new, enhanced features that help operators work more effciently. The YS will work effciently in petrochemical, chemical, power, pulp and paper, boiler and combustion control applications. A YS beyond... With the YSS setting software, you can convert your SLPC and YS7 programs with YS7 programs. YS and YS8 compatible models also available. with 7 x mm cutout FM/CSA certification planned Envision a plant... YS Series is a core building block of Yokogawa's VigilantPlant solutions that promise to bring operational excellence. 3

3 Easy to use Functions that support process operations Color LCD that s easy to see and easier to use. Meter display Event Display TREND Display ALARM Display Digital values displayed side-by-side with an intuitive analog meter makes the YS the perfect replacement for YS8 or obsolete moving coil controllers. Displays when events are occurring. messages can be displayed in English, Chinese, Japanese and other languages. Your selection of up to analog inputs or outputs can be displayed as trends. Color LCD alarm display makes it easy to identify and review alarm activity. Single-loop controller LOOP Display Loops color-coded for easy identification DUAL Display Ideal for -element control such as cascade or selector control Uses a TFT LCD + LED back light display Maintains good visibility, even on panels subject to direct morning and evening sunlight. Note: Avoid constant exposure to sunlight as this can shorten the lifespan of the LCD display. Designed with a lightweight, compact case YS mm,. kg YS 3 mm, 3. kg YS8 8 mm, kg YS8 YS YS Provides for greater freedom of instrumentation design Compact, lightweight design allows the use of smaller and less expensive panel. Moreover, it allows attachment to doors which was previously difficult.

4 Reduction of engineering costs YS Configuration and Programming Software Your Choice of Programming Style: Graphical or Text Based New Graphic Programming Tool Original Text Based Programming Supports on-line module monitoring function Program capacity Supports Blocks YS7 Backwards compatible with existing programs. Conversion software for existing YS7 user programs is available. Program capacity Supports steps.. times of the previous YS7. SLPC Backwards compatible with existing programs. Conversion tool for importing programs from YS8 SLPC ROM is available. Programming is easier with our intuitive function block programming. The online module monitoring function allows you to confirm the performance while programming. Backwards compatible with existing YS7 users programs. Increased programming capacity allows you to create more sophisitated control schemes. Three connection modes Full set of computation functions Connection modes: USB, Ethernet or RS8 When connecting via RS8 or Ethernet, a communication option is required on the main unit. Configuration and Programming Software YSS Ethernet communications Dedicated USB cable RS8 communication Supports parameter setting for all YS models Support for YS7 custom programming. - Calculations done using Engineering units and Floating point math. - Includes over one-hundred computation modules for exponents, logarithms, temperature/pressure correction, and other operations. - Function blocks (sub-programs) can be saved and reused. Password protection function Passwords can be assigned to user programs to prevent unauthorized access to proprietary programs. A password on the main unit prevents unexpected changes in the engineering parameters. Calibration tool Following the YSS s online calibration instructions makes calibration easy. Calibration records and data can be saved on the YS, allowing you to load or print past calibration data as needed.

5 High reliability Improved process up time Control output backup function The control output backup function comes standard with YS series controllers (YS7 and YS) and the Manual Station for MV Setting (YS3). Dual CPU Battery free memory backup Nonvolatile memory is used for memory backup. Service life is improved because no batteries, backup capacitors, or other components are used. Improved basic control performance Display signal Display CPU Display CPU's process at normal condition Main CPU's process at normal condition Back-up process at fail Main CPU The YS series achieves higher performance than previous models (YS series). I/O accuracy Voltage input accuracy: ±.% ±.% Voltage output accuracy: ±.3% ±.% Current output accuracy: ±.% ±.% Internal data resolution of the I/O signal: / / Internal computation resolution of PID and other computations: / /3 MV operation Key operation Control Circuit D/A converter A/D converter MV MV Output Circuit Hard Manual MV AC/DC power supply resists powerline fluctuations. The AC/DC (V/V) power supply powers the instrument to provide consistent performance.also accepts DC power regardless of polarity (specify V power supply when ordering). With dual-cpu construction (main CPU and display CPU), manual control capability and display continues even if an abnormality occurs on one of the CPUs. If controller self-diagnostics detects a control circuit failure, the controller can suspend analog/digital output, switch to manual mode and allow manual control by operator. Functions Failure area Control with Hard manual Manual operation with front keys Main CPU fail Display CPU fail Display for and Control algorithm stop stop All CPU and Control Circuit stop Controller online replacement function (portable manual station) Use the YS portable manual station when exchanging or performing maintenance on a controller. You can switch to the spare controller without interrupting the control output. Manual operation Hard manual Front Panel YS7, YS Controller YS Portable manual station Manual operation is possible even if all CPUs and control circuits are in a fail state. Replace the display while retaining output. The display unit is replaced by Yokogawa service personnel. Recommended LCD replacement period: 8 years Hard manual operation wheel Independent manual override is built into the control circuits, ensuring that control output can continue even when a control circuit including the CPU experiences a problem. Brightness (%). Slow to deteriorate New YS Previous model. Year * Test data of our company

6 Powerful and Flexible System connectivity functions Ethernet support The instrument can be easily connected to DAQWORX, SMARTDAC+ general-purpose SCADA, and OPC servers via Ethernet (Modbus/TCP). Measured data from the YS can be recorded on the GX. Note: The GX requires the communication channel function option (/MC). Ethernet (Modbus/TCP) Ethernet (Modbus/TCP) Expandable I/O Additional I/O can be added by selecting the YS7 basic model (with Expandable I/O). The total number of input/outputs points with the main unit and Expandable I/O are 8 analog inputs, analog outputs, and DI/DO. External AI: 3 inputs External AO: outputs External DI: points External DO: points GX/GX Note: An interface for the additional Expandable I/O cannot be added after delivery. If there is a possibility that extra input/outputs will be needed, we recommend that you start with the basic model (with expansion I/O). with PLC Connections are enabled using the FA-M3 s UT link module and the RS8 communication function. No programming is necessary to exchange data between the instrument and the FA-M3. RS8 FA-M3 with CENTUM As with previous models, communication with Yokogawa s DCS (CENTUM) is supported. This is ideal for DCS backup in chemical plants and other applications requiring extreamly high reliability. Applicable Models: YS7, YS, YS3, and YS3 CENTUM VP HIS FCS FCU Control bus ALR Please specify the communication options /A3 (RS-8 communication) to directly communicate with the CENTUM. YS7 YS7 YS7 The YS can also be connected to PLCs of various manufacturers via the Modbus communication protocol. Note: Direct communication with CENTUM. RS8 YS7 YS YS3 YS3 Peer-to-peer communication function A sample of System Construction With peer-to-peer communication, up to 3 YS7 can be connected interchangeably. Four of the connected instruments can each output points of analog data and points of status data. This makes data exchange and I/O sharing possible since all instruments under peer-to-peer communications can read all data ( analog and status data). This is optimal for multi-loop control as such with boiler instrumentation. I/O sharing Data sharing RS8 Field instruments Inter-lock system YS3 Upper system YS7 Note: Does not support the YS series peer-to-peer communication network (YS-net). YS Maximum no. of connections : 3 No. of receiving units : 3 No. of transmitting units : Transmitted data : analog and status data per transmitting YS7 interval : ms average (not synchronized to the control computation interval) YS3 YS3 Field wiring Signal in the panel 7

7 TAGTAGTAG MV 3. % ALARM STC-ON C. STC ON. C O C Compatibility Total cost reduction Cases and housing for replacing old models Indispensable for lasting, stable operations at the plant when replacing instrumentation. Case and housing are available for replacement of older-model SLCs by Yokogawa Electric Corp. (the EBS, I, EK, and HOMAC series) allowing you to exchange instruments without modifying existing instrumentation panels. Moreover, front panel design with analog-like meters lets you update to new instruments without losing the familiarity of the old interface. line* YS* YS8* YS8* EK* I,EBS* YS compatible type internal unit Case Housing Case Housing Housing Housing *: Compatibility is established by inserting the YS s internal circuitry of the appropriate compatible type into the existing case. *: Compatibility is established by inserting the entire YS unit of the appropriate compatible type into the existing controller housing. Order the housing separately as needed. YS8 YS Self-tuning (STC) Simplifies tuning when starting up or changing the process unit under control. Setpoint filter (F) Can optimize tracking with changes in set-points. Also can maintain optimum responsiveness to disturbances. Before STC After STC Before STC P = 8% P = 8% P = % I = sec. I = sec. I = sec. MV 8 D = sec. SFA =. MV 8 D = sec. SFA =. P V P V P V Time (min.) Time (min.) Time (min.) SFA : F Parameter MV 8 D = sec. SFA =. At disturbance optimum responsiveness to disturbances. At set-point change without F Set-point change with F optimize tracking with changes in set-points Flexible DI/DO The YS7/YS s six DI/DO terminals can be used for both input and output. Programmable function key With a user program, the program function key (PF key) on the instrument s front panel can be used as an ON/OFF switch for self-tuning, or as a Start button for sequence operation. Direct input function* An optional signal conversion function can be added for channel. Current, voltage pulse, thermocouples, RTDs, mv and potentiometers signals from differential pressure gauges, manometers, and flow meters can be connected directly to the controller. The direct input employs highly noise resistant, isolated inputs. TC mv RTD LOOP C 3. C 7.3 H.MAN C A M Pulse wire transmitter * Options available for suffix code,, of Type. 8

8 Applications Automatic Boiler Control An appropriate distribution of control functionality enables safe and stable automatic boiler control. (Boiler master) Main steam pressure control FF Fx Feed water level control Cascade PRD control FF Residual Chlorine Control With the -loop control function, you can control hypochloric flow control and residual chlorine. Loop : Hypochloric flow control Calculates hypochloric infusion from the flow, infusion rate, concentration, and specific gravity, and controls the flow. Loop : Controls residual chlorine Control is achieved by receiving signals from a residual chlorine analyzer. The infusion rate from loop is corrected by this control output. Steam X Air flow control Fuel flow control Drum level Main steam pressure Main steam flow Feed water X3 X Y Exhaust gas oxygen Fx concentration control Fuel oil Fuel oil flow Air flow Oxygen Exhaust concentration gas Pump Air Residual chlorine analyzer -Cascade Primary Direct (PRD) control: Enables stable level control when the boiler is started. -Cross limiting control calculation: Air and fuel flow are calculated so that air flow always exceeds fuel flow to prevent incomplete combustion and explosion. -Feedforward (FF) control: The main steam pressure and feed water level are controlled quickly in response to changes in the main steam flow. Water Flow Flow Models and Suffix Codes (See General Specification Sheets for the ordereing information in the detail.) Suffix codes can be used to select models with or without manual control. YS7 YS YS3 YS3 YS3 Use Type Model Suffix code option code Description Direct input * 3 Certification /A /A /A3 /A /A /A /A7 /A8 /DF /A3 /A3 /A3 /FM /CSA Programmable Indicating controller Indicating controller Indicator with alarm Manual setter for setting Manual setter for MV setting In case of YS7, YS and YS3: With hard manual unit In case of YS3 and YS3: Always - Without hard manual unit Basic type Basic type with expandable I/O * type for YS (with YS case) CE marking, IP CE marking, IP CE marking type for YS8 internal unit, type for EBS, I, EK and HOMAC type for YS8 ( size for YS8 with YS terminal) type for line (with YS terminal) VAC, VDC VAC mv input Thermocouple input RTD input Potentiometer input Isolator -wire transmitter input (isolated) -wire transmitter input (non-isolated) Frequency input Direct input with Fahrenheit temperature range function * 7 RS-8 communication (PC-link, Modbus, YS protocol, Peer-to-peer) * * DCS-LCS communication * Ethernet communication (Modbus/TCP) * FM nonincendive approved (FM Class I, div ) * (To be approved) CSA safety and nonincendive approved (Class I, Division ) * (To be approved) Model Suffix code option code Description YSS - Setting software for YS series Always Always (with CD Media and proprietary cable) Accessories (sold separately) Product name SHUP standard housing SHUP long housing SHUP EK/HOMAC housing Line pneumatic instrument replace housing Ω terminating resistor Ω shunt resistor Option User programming Expandable I/O Ethernet communication RS8 communication (PC-link, Modbus, YS protocol) RS8 communication (Peer-to-peer) DCS-LCS communication Direct input Model SHUP- SHUP- SHUP- YS YS YS YS7 ( * ) ( * ) ( * 3) Remarks Available for YSxx-x3x (Replace for YS8 Series) Available for YSxx-x3x (Replace for I Series or EBS Series) Available for YSxx-x3x (Replace for EK or HOMAC Series) Available for YSxx-xx (Replace for Line pneumatic instrument) For RS-8 communication For a built-in V transmitter power supply YS ( * ) * Can be added only for basic type (when selecting type or ) * Can be added for basic type (when selecting type or ) or compatible type for YS (when selecting type ""). *3 Can be added only for compatible type for YS (when selecting type, and ). Multiple selections are not possible. * Cannot be combined with type 3 * For basic type with expandable I/O only (when selecting type ). An expansion I/O terminal (model: YS) and expansion I/O cable (model: YS) are included. * /A3 and /A3 cannot be specified together. Please specify the communication options /A3 (RS-8 communication) to directly communicate with the CENTUM CS3/VP. Please specify the communication options /A3 (DCS-LCS communication) to communicate with the CENTUM through the SCIU. *7 This option can be combined only with option code /A or /A3.If option code /DF is specified, Fahrenheit temperature range can be available for direct input range in addition to Centigrade temperature range. In case of specifying Fahrenheit temperature range for direct input, option code /DF is required. When the direct input temperature range may be changed to Fahrenheit temperature range after shipment, also specify option code /DF. ( * 3) YS3 ( * ) ( * 3) YS3 ( * ) ( * 3) YS3 ( * ) ( * 3)

9 YS Series Line-up YS7 Programmable Indicating Controller Incorporates A programmable controller in which control and computational functions are combined by the user with the YSS programming tool. Each YS7 can run two PID control calculations simultaneously and output the respective - ma output signals. The YS7 can also be used as a multi-function controller without programming, in the same way as the Model YS. Indicating Controller YS fundamental control functions required for PID control. Necessary functions can be selected in accordance with the user s purpose. The available functions include those necessary for input signal processing, such as square root extraction and linear segment conversion, and feed-forward calculation. Cascade and autoselector control is also possible. Controller mode Control type Control period Additional control function Extended control function Auxiliary control function Analog input Analog output Alarm function Digital signal Retransmission output Input computation Output computation Computation modules Program method Program capacity Security Hardmanual Programmable, Multi-function mode (single-loop, cascade and auto-selector) Basic PID control (built-in nonlinear control function), proportional control (built-in nonlinear control function), sampling PI control, (built-in sampling PI control function), and batch PID control.,. and. sec (programmable mode),. sec (multi-function mode) Adjustable setpoint filter (F), Self-tuning (STC), Non-linear PID control, PID control with reset bias function, output limiter, external cascade-control setpoint signal Input/output compensation, Variable gain, preset PID Feed-forward control, output tracking, preset MV output, / tracking, operation mode change, input filter, Square-root, -line-segment characterizer, ratio to V DC ( channels or 8 channels with with expandable I/O) to ma (or channels), to V DC ( channels or 3 channels with expandable I/O) High/low/high-high/low-low limits, deviation limit, and velocity alarm Six channels (each being common to both input and output),,,, and other analog inputs Square-root with low signal cut off, -line-segment characterizer, first-order lag calculation, scaling of external cascade-control setpoint signal, feed-forward signal calculation Output high/low limiting Four arithmetic operations, square-root, absolute, selector, limiter, ten segmen characterizer, alarm, first-order lag, differentiation, dead time, velocity computations, moving average, timer, program setting, counter, pulse output, temperature/pressure compasations, power, logarithmic, logic computations, comparison, branching, switching, sub-program and register manipulation Function block or text (use YSS configuration and programming software) modules (function block), steps (text) Protection by password Modbus/TCP, RS-8 (modbus, peer-to-peer), and DCS-LCS Yes/No Controller mode Control type Control period Extended control function Auxiliary control function Analog input Analog output Alarm function Digital signal Retransmission output Input computation Output computation Security Hardmanual single-loop, cascade and auto-selector Basic PID control (built-in nonlinear control function), proportional control (built-in nonlinear control function), sampling PI control, (built-in sampling PI control function). sec Adjustable setpoint filter (F), Self-tuning (STC), Non-linear PID control, PID control with reset bias function, output limiter, external cascade-control setpoint signal Feed-forward control, output tracking, preset MV output, / tracking, operation mode change, input filter, Square-root, -line-segment characterizer, ratio to V DC ( channels) to ma ( channel) and to V DC ( channels) High/low/high-high/low-low limits, deviation limit, and velocity alarm Six channels (each being common to both input and output),,,, and other analog inputs Square-root with low signal cut off, -line-segment characterizer, first-order lag calculation, scaling of external cascade-control setpoint signal, feed-forward signal calculation Output high/low limiting Protection by password Modbus/TCP, RS-8 (modbus), and DCS-LCS Yes/No YS3 Indicator with Alarm YS3 Manual Setter for Setting YS3 Manual Setter for MV Setting YS Portable Manual Station Indicating alarm monitor with two inputs for simultaneous monitoring of two loops. High-high, high, low, and low-low alarms can be detected for each of the two inputs, and logical ANDs or ORs of arbitrary alarms can be set. From among these, a total of six alarms can be assigned to alarm output contacts. This manual loader allows an operator to send a setpoint to a remote controller. Its operation mode is switched by the mode keys (C and M) or a status input. A status identification output is provided as standard. This manual loader allows an operator to interrupt a control signal to a final control device and manually control it's operation temporally. Its operation mode is switched by the mode keys (C and M) or a status input. A status identification output is provided as standard. When a YS7, YS or YS3 requires maintenance, the YS Portable Manual Station can be used to output a - ma signal to the final control element. Simply swing up the front panel of the controller, connect this unit to the controller, and replace the internal assembly while keeping the existing manipulated output active. Analog input Digital signal Alarm functions Input computation Security Trend display to V DC ( channels) Six outputs(with one for digital input as backlight off) and one FAIL contact High/low/high-high/low-low limits Square-root with low signal cut off, first-order lag calculation Protection by password, Modbus/TCP, RS-8 (modbus), and DCS-LCS Analog input Analog output Digital signal Alarm functions Input computation Security Trend display to V DC ( channels) to V DC ( channel) Two input, three outputs and one FAIL contact High/low limits Square-root with low signal cut off Protection by password,, MV, and other analog inputs Max. points Modbus/TCP, RS-8 (modbus), and DCS-LCS Analog input Analog output Digital signal Alarm functions Input computation Security Trend display Hardmanual to V DC ( channels) to ma ( channel) and to V DC ( channel) Two input, three outputs and one FAIL contact High/low limits Square-root with low signal cut off Protection by password,, MV, and other analog inputs Max. points Modbus/TCP, RS-8 (modbus), and DCS-LCS Yes/No Input signal Manipulation signal Input/manipulation signal meters Output manipulation I/O connection Models to be backed up to V DC ( channel) to ma DC ( channel) Moving-coil method Range: to % Scaling: equal divisions Manual using the front-panel dials I/Os are coupled with the connector on the case using a dedicated cable. YS7, YS, YS3

10 Block YS7/YS Arrangements YS7 YS7/YS No. Programmable mode Single-loop mode Cascade mode Selector mode Analog input Analog input Analog input 3 Analog input Analog input Cascade set point input Tracking input Feedforward input output (* ) Cascade set point input Feedforward input output (* ) Cascade set point input Cascade set point input output (* ) 3 Transmitter (V DC) Transmitter (V DC) Transmitter (V DC) Transmitter (V DC) SDA () SDB () SDA () SDB () SDA () SDB () SDA () SDB () 7 8 RDA ()or LCS () RDA ()or LCS () RDA ()or LCS () RDA ()or LCS () RDB ()or LCS () RDB ()or LCS () RDB ()or LCS () RDB ()or LCS () Direct input (*) Analog output (ma DC) Analog output Analog output 3 (ma DC/-V DC) Digital output or Direct input (* ) MV (ma DC) MV high limit alarm Direct input (* ) MV (ma DC) MV Direct input (* ) MV (ma DC) MV Digital input output First loop alarm output First loop alarm output 3 Digital output or low limit alarm Second loop alarm output 3 Digital input output Second loop alarm output 3 Digital output 3 or 33 Digital input Deviation alarm output O/C status output L/R status output 3 Digital output or 3 Digital input 3 C/A M status output C/A M status output C/A M status output 3 Digital output or 37 Digital input C A/M status output C A/M status output C A/M status output 38 3 L Digital output or Digital input Action mode switching input Action mode switching input Action mode switching input N G Ground (GND) Ground (GND) Ground (GND) Ground (GND) *: Only applicable for YS compatible terminal type ( ) YS Series (Basic Type) Block YS3/YS3/YS3 Arrangements No. YS3 YS3 YS output (* ) Cascade set point input output (* ) Cascade input output (* ) 3 Transmitter (V DC) Transmitter (V DC) Transmitter (V DC) SDA () SDB () SDA () SDB () SDA () SDB () 7 8 RDA () RDB () RDA ()or LCS () RDA ()or LCS () RDB ()or LCS () RDB ()or LCS () Direct input (* ) Alarm output Alarm output Alarm output 3 Direct input (* ) high limit alarm output low limit alarm output Direct input (* ) MV (ma DC) MV high limit alarm output low limit alarm output 3 Alarm output C/M status output C/M status output 3 37 Alarm output Input for LCD backlight off Input for LCD backlight off 38 3 L Alarm output or Degital input Action mode switching input Action mode switching input N G Ground (GND) Ground (GND) Ground (GND) YS Expandable I/O Arrangements number Expandable I/O Analog input Analog input 7 Digital input 7 Digital input 8 Digital input Digital input number Expandable I/O Analog input 8 Analog output ( to VDC) Digital output 7 Digital output 8 Digital output Digital output Our product names or brand names mentioned in this manual are the trademarks or registered trademarks of YOKOGAWA Electric Corporation (hereinafter referred to as YOKOGAWA). Microsoft, MS-DOS, and Windows are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries. Ethernet is a registered trademark of XEROX Corporation. We do not use the TM or mark to indicate these trademarks or registered trademarks in this user s manual. All other product names mentioned in this user s manual are trademarks or registered trademarks of their respective companies.

11 7 Dimensions Main Unit Dimensions (YS Basic Type) (YS Basic Type with Expandable I/O) When swung up 7 Note Instrument panel thickness:.3 to mm Clamp bracket 7.8 Expandable I/O cable (YS7 with Expandable I/O). Clamp bracket R MIN. 3 MIN Note Weight: Main unit. kg + Expandable I/O Cable 3 g Note : If a nameplate, etc. is installed within mm above the instrument, the height of the nameplate, etc. must be 3 mm or less from the panel surface. Note : When installing the expandable I/O cable, secure the wiring space of at least mm for a minimum curvature radius of the cable in addition to the mountiing bracket space of 7 mm from the terminal cover face of the main unit. Expandable I/O Dimensions Expandable I/O Cable Dimensions (7) R MxL8 -n. Ground wiring:. mm, green Length: ± mm (when mounted on DIN rail) Weight: g Panel Cutout Width (For single mounting) (For side-by-side mounting) Third angle projection 3 Unit: mm General tolerance: ±(value of tolerance class IT8 based on JIS B -8)/ or more 37 + or more L Panel Cutout Width for Side-by-side Mounting Number of instruments L (mm) to be mounted () 3 ± mm () Weight: 3 g *: When attaching a nameplate or the like to the panel within mm above this instrument, ensure that its thickness is less than 3 mm. *: To ensure adequate ventilation, allow space of at least mm above and below the panel. *3: Front display of YS7 and YS are shown, and they are slightly different from that of YS3 (keytop and front plate and the like). YOKOGAWA CORPORATION OF AMERICA Dart Road, Newnan, Georgia 3, U.S.A. Phone: , Fax: () YOKOGAWA EUROPE B.V. Euroweg, 38 HD Amersfoort, THE NETHERLANDS Phone: (3)-88-, Fax: (3)-88- YOKOGAWA ENGINEERING ASIA PTE. LTD. Bedok South Road, Singapore 7 Phone: ()-33, Fax: ()- YOKOGAWA ELECTRIC CORPORATION Control Instruments Business Division --3 Nakacho, Musashino-shi, Tokyo, 8-87 Japan Phone: (8)---77, Fax: (8) ns@cs.jp.yokogawa.com Represented by : Sign up for our free newsletter Vig-RM-E Printed in Japan, (KP) [Ed : /b] Subject to change without notice. All Rights Reserved, Copyright c, Yokogawa Electric Corporation.

Single Loop Controller YS1000 Series

Single Loop Controller YS1000 Series Single Loop Controller YS Series Single Loop Controller Bulletin B8A-E www.ys.com Easy to use Color LCD display with a wide variety of screens Designed with a lightweight, compact case. Programs using

More information

General Specifications

General Specifications General Specifications GS 33K15C20-50E Model LFS1500 Control Function for Field Control Station (for AFV10, Vnet/IP and FIO) Model LFS1550 Node Expansion Package (for AFV10 ) GENERAL Model LFS1500, Control

More information

Nuclear Solutions. Data Acquisition, Control, and Monitoring Solutions for Nuclear Power. Bulletin 04L70B01-02E-A

Nuclear Solutions. Data Acquisition, Control, and Monitoring Solutions for Nuclear Power. Bulletin 04L70B01-02E-A Nuclear Solutions Data Acquisition, Control, and Monitoring Solutions for Nuclear Power Bulletin 4L7B1-2E-A Newnan, GA Calgary, Canada Houston, TX Mexico City Yokogawa provides proven and highly reliable

More information

Technical Information

Technical Information Technical Information YS1000 Replacement Guide Overview, Model Conversion l tiona Func cement n Enha The contents of this Technical Information are subject to change without notice. Yokogawa Electric Corporation

More information

Compact Controller M CC-M

Compact Controller M CC-M Fuji Instrumentation & Control Fuji Digital Controller Compact Controller M ECNO:1127a FUJI Electric declares a multi-loop controller era The Compact Controller M is a multi-loop controller of a new era

More information

General Specifications

General Specifications General Specifications Model VP6F1250 Generic Subsystem Gateway Package [Release 6] GENERAL is an operation and monitoring station for subsystems that are pre-process and post-process pieces of equipment

More information

General Specifications

General Specifications General Model I/O Module (for N-IO) GS 32P06K30-01EN GENERAL This General (GS) provides the hardware specifications of I/O module (for N-IO) that can be mounted on the Base Plate for N-IO I/O (S2BN1D,

More information

General Specifications

General Specifications General Model I/O Module (for N-IO) GS 32P06K30-01EN GENERAL This General (GS) provides the hardware specifications of I/O module (for N-IO) that can be mounted on the Base Plate for N-IO I/O (S2BN1D,

More information

/8 DIN Universal Process Indicator

/8 DIN Universal Process Indicator Data Sheet SS/_ High visibility LED display the clearest view of your process status.% measurement accuracy precise indication of process measurement Analog and relay outputs as standard alarm and retransmission

More information

Compact data logger offering best-in-class noise resistance and communication function

Compact data logger offering best-in-class noise resistance and communication function T M Portable Data Station XL100 Series Compact data logger offering best-in-class noise resistance and communication function A world s first in measuring instruments! To obtain IPv6 Ready Logo Phase-1

More information

Instruction Manual. Model US1000 Digital Indicating Controller. IM 5D1A01-01E 3rd Edition IM 5D1A01-01E

Instruction Manual. Model US1000 Digital Indicating Controller. IM 5D1A01-01E 3rd Edition IM 5D1A01-01E Instruction Manual Model US1000 Digital Indicating Controller 3rd Edition Introduction This instruction manual describes the general operation of the US1000 Digital Indicating Controller. Intended Readers

More information

Compact Controller M<CC-M>

Compact Controller M<CC-M> Fuji Instrumentation & Control Fuji Digital Controller Compact Controller M ECNO:1127 FUJI Electric declares a multi-loop controller era Compact Controller M is a multi-loop controller of a new era where

More information

YS1000 Series Communication Interface User's Manual

YS1000 Series Communication Interface User's Manual User s Manual YS1000 Series Communication Interface User's Manual Functional Enhancement 2nd Edition Introduction Thank you for purchasing the YS1000 series single-loop controller (hereinafter referred

More information

Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3.

Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3. Data Sheet T 6493 EN TROVIS 6400 Automation System TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and

More information

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS 18 channels for HART / Modbus RTU sensors 2 digital channels 16 math channels 4 relay outputs for alarm or control

More information

SLC RetroPAK Controllers

SLC RetroPAK Controllers SLC RetroPAK Controllers Replaces aging, obsolete Bailey SLC and CLC controllers Highly reliable, high-visibility display Peer-to-peer and Modbus RS-485 communications Data Quality detection on all inputs,

More information

Trident and Trident X2 Digital Process and Temperature Panel Meter

Trident and Trident X2 Digital Process and Temperature Panel Meter Sign In New User ISO 9001:2008 Certified Quality System Home Products Online Tools Videos Downloads About Us Store Contact Policies Trident and Trident X2 Digital Process and Temperature Panel Meter Products

More information

SX90 Process Controller

SX90 Process Controller Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

General Specifications

General Specifications General Specifications GS 33J62F40-01EN Models A2BN3D, A2BN4D, A2BN5D Base Plates (for N-IO) System models: A2ZN3D, A2ZN4DC, A2ZN5DC N-IO I/O Unit GENERAL This General Specifications (GS) describes the

More information

MODCELL 2050R Single Loop Controllers

MODCELL 2050R Single Loop Controllers Isolated universal process and remote set-point input Four internal set-points No jumpers required to define instrument parameters Ratio/bias on process and remote set-point Totalizer Ramp/soak profile

More information

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882 1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882 This manual is intended for use in support of installation, commissioning and configuration of the 1/32-DIN Temperature

More information

SystempaK (Digital/File Type) Dual Input Arithmetic Relay Module Model J-SCM 92/97

SystempaK (Digital/File Type) Dual Input Arithmetic Relay Module Model J-SCM 92/97 No.SS2-2320-0950 (Rev. 1) SystempaK (Digital/File Type) Dual Input Arithmetic Relay Module Model J-SCM 92/97 Introduction The Dual Input Arithmetic Relay Module is an advanced arithmetic module that can

More information

Eurotherm advanced controllers providing solutions for simple to demanding applications...

Eurotherm advanced controllers providing solutions for simple to demanding applications... Eurotherm advanced controllers providing solutions for simple to demanding applications......with unique levels of control and flexibility Eurotherm 2604-2704 Unique Levels of Flexibility Setpoint Programmer

More information

353 RetroPAK Controllers

353 RetroPAK Controllers 353 RetroPAK Controllers Replaces obsolete Moore 352 and Siemens 353 controllers Easy migration for operators and engineers Fits the same panel cut-out Peer-to-peer, Modbus RS-485, and Ethernet Modbus/TCP

More information

LAUREL ELECTRONICS, INC.

LAUREL ELECTRONICS, INC. Description LAUREL ELECTRONICS, INC. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations Features Available for turbine flow meter pulse signals

More information

Operating Instructions 12/2010 MN Z-EN XV-152 MICRO PANEL

Operating Instructions 12/2010 MN Z-EN XV-152 MICRO PANEL Operating Instructions 12/2010 MN04802006Z-EN MICRO PANEL 2 Device description 2.3 Device versions 2.3 Device versions Fig. 1 MICRO PANELs are available in the following versions: Basic device Display

More information

TABLE OF CONTENTS INTRODUCTION. 3. Analog Input Analog Output Digital Input Digital Output OPERATIONAL DESCRIPITON.. 7 PROGRAMMING AND INITIAL SETUP.

TABLE OF CONTENTS INTRODUCTION. 3. Analog Input Analog Output Digital Input Digital Output OPERATIONAL DESCRIPITON.. 7 PROGRAMMING AND INITIAL SETUP. DIVERSIFIED HEAT TRANSFER SERIES 700 STEAM GENERATOR CONTROLLER INSTRUCTION MANUAL VISIT OUR WEBSITE AT SIGMACONTROLS.COM SERIES 700 DHT STEAM GENERATOR MANUAL 042514 2 TABLE OF CONTENTS INTRODUCTION.

More information

5450 NW 33rd Ave, Suite 104 Fort Lauderdale, FL Fruitland Ave Los Angeles, CA UM Channel Monitor.

5450 NW 33rd Ave, Suite 104 Fort Lauderdale, FL Fruitland Ave Los Angeles, CA UM Channel Monitor. 5450 NW 33rd Ave, Suite 104 Fort Lauderdale, FL 33309 3211 Fruitland Ave Los Angeles, CA 90058 UM-600 6-Channel Monitor Version 2 Installation and Operation Manual Rev. G P/N145F-12990 PCO 00007462 (c)

More information

DIGITAL CONTROLLER Multi-Loop. smar

DIGITAL CONTROLLER Multi-Loop. smar DIGITAL CONTROLLER Multi-Loop smar INTRODUCTION The CD600Plus is a powerful stand-alone single-station process controller. It is capable of simultaneously controlling up to 4 loops with up to 8 PIDs and

More information

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current Data sheet SIMATIC S7-1200F, CPU 1215 FC, COMPACT CPU, DC/DC/DC, 2 PROFINET PORT, ONBOARD I/O: 14 DI 24VDC; 10 DO 24V DC 0.5A; 2 AI 0-10V DC, 2 AO 0-20MA DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA

More information

Paperless Recorder VGR-B100. Series

Paperless Recorder VGR-B100. Series Paperless Recorder VGR-B100 Series CE marking RoHS compliant Easy-to-Use! Paperless Recorder with Touch Screen VGR-B100 Easy Operation! Touch Screen Operation User friendly interface through a 5.7 inch

More information

BMS Steam Station Solutions

BMS Steam Station Solutions BMS Steam Station Solutions rtk@circor.com www.circorenergy.com Compact Programmable Controller Touch Screen Operator Panel MP-02 CPU Modem / Router Remote management using a SMARTphone Remote management

More information

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm) 4-20 ma & Relay Output Features 4-20 ma, ± 10 V, TC & RTD Inputs 12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm) 24 VDC @ 200 ma Transmitter Power Supply Options Type

More information

General Specifications

General Specifications General Specifications Models ALR111, ALR121 Serial Communication Modules GS 32Q06K50-31E GENERAL This document describes about Models ALR111 and ALR121 Serial Communication Modules used with a safety

More information

/8 DIN Motorized Valve Controller

/8 DIN Motorized Valve Controller Data Sheet SS/_5 Boundless motorized valve controller no need for slidewire feedback; improves reliability Two sealed 5A control relays suitable for direct connection to the valve, reducing installation

More information

SX 6000 Paperless Recorder

SX 6000 Paperless Recorder SILVER AUTOMATION INSTRUMENTS HTTP://WWW.SILVERINSTRUMENTS.COM RUNYI GROUP SX 6000 Paperless Recorder Product Overview SX6000 Paperless Recorder color-screen paperless recorder has 16-channel universal

More information

ABB Instrumentation. Specification DataFile COMMANDER 100. the-easy-to use 1. /8 DIN controller with extensive application capabilities

ABB Instrumentation. Specification DataFile COMMANDER 100. the-easy-to use 1. /8 DIN controller with extensive application capabilities COMMANDER Universal Process Controller Specification DataFile PID controller with one shot autotune single loop, heat/cool and ramp/soak as standard Quick code, front face or PC configuration easy commissioning

More information

PXR Series Advanced Self-Tuning Temperature and Process Controllers

PXR Series Advanced Self-Tuning Temperature and Process Controllers PXR Series Advanced Self-Tuning Temperature and Process Controllers Key Features PID Description with fuzzy control of self-tuning 16 Ramp/soak segments Large LED display Auto-tune Timer function Heater

More information

Extruder Controls ExtruVision S

Extruder Controls ExtruVision S Extruder Controls ExtruVision S ExtruVision S - The compact system solution for controlling, visualization, and operating extrusion systems Combination of control panel BA Touch with 5.7'' monitor and

More information

General Specifications

General Specifications General Specifications GS 33J62F40-01EN Models A2BN3D, A2BN4D, A2BN5D Base Plates (for N-IO) System Models: A2ZN3D, A2ZN4DC, A2ZN5DC N-IO I/O Unit GENERAL This General Specifications (GS) covers the specifications

More information

INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx

INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual PCMNET V 7. xx INTEGRATED SYSTEMS AND CONTROLS, INC. PCMNET Users Manual Revised 2/4/2005 2003-2005 Integrated Systems and Control. Inc. PO Box

More information

MULTI-FUNCTION PROCESS CONTROL TEACHING SYSTEM PCT40

MULTI-FUNCTION PROCESS CONTROL TEACHING SYSTEM PCT40 PCT SERIES: PROCESS CONTROL TECHNOLOGY MULTI-FUNCTION PROCESS CONTROL TEACHG SYSTEM PCT40 CAPABILITIES > The basic PCT40 is used under computer control to demonstrate a variety of single control loops.

More information

DIGITAL INDICATING CONTROLLER

DIGITAL INDICATING CONTROLLER DB1000 SERIES DIGITAL INDICATING CONTROLLER The DB1000 series is a 96 96mm digital indicating controller with the indicating accuracy of ±0.1% and the control cycle of approximately 0.1 seconds. Various

More information

technical datasheet technical datasheet MTL660 Displays Loop-powered indicators for hazardous areas

technical datasheet technical datasheet MTL660 Displays Loop-powered indicators for hazardous areas technical datasheet technical datasheet MTL0 Displays Loop-powered indicators for hazardous areas Loop powered -0mA Field and panel mounting Environmental protection to IP7 Easy to configure Number of

More information

MODEL: SC100. Single Loop Controller Series. MULTI-FUNCTION PID CONTROLLER (color LCD with touch-panel) MODEL: SC100 [1]0 [2][3]

MODEL: SC100. Single Loop Controller Series. MULTI-FUNCTION PID CONTROLLER (color LCD with touch-panel) MODEL: SC100 [1]0 [2][3] Single Loop Controller Series MULTI-FUNCTION PID CONTROLLER (color LCD with touch-panel) 44 (5.67) 7 (.83) * mm (inch) *Selectable with option code /4: 400 mm /6: 600 mm Language blank: Japanese /E: English

More information

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current Data sheet SIMATIC S7-1200F, CPU 1214 FC, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 14 DI 24V DC; 10 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY 125 KB General information

More information

General Specifications

General Specifications General Model A2MMM843, A2MDV843 I/O Modules (for N-IO) GS 33J62F20-01EN GENERAL This general specifications (GS) contains hardware specifications of I/O modules (for N-IO) that can be mounted on the base

More information

Explosion-Proof Gauge Pressure Transmitter

Explosion-Proof Gauge Pressure Transmitter Technology Solutions T EK-B AR 3120A Explosion-Proof Gauge Pressure Transmitter PRESSURE www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction The Tek-Bar

More information

LAUREL. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations ELECTRONICS, INC.

LAUREL. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations ELECTRONICS, INC. Description LAUREL ELECTRONICS, INC. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations Features Available for turbine flow meter pulse signals

More information

General information. Display. Supply voltage

General information. Display. Supply voltage Data sheet SIMATIC S7-1200, CPU 1211C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 6 DI 24V DC; 4 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 50 KB General information Product

More information

Saved Data playback Saved data in Memory card can be easily called out and played back on display

Saved Data playback Saved data in Memory card can be easily called out and played back on display Paperless Recorder Type:PHF Long Term Record Data Saving 4years in Compact Flash (In case of using 512MB Compact Flash) Saved Data playback Saved data in Memory card can be easily called out and played

More information

deltadue series DIN rail mounting modules for control and data acquisition

deltadue series DIN rail mounting modules for control and data acquisition DIN EN ISO 9001 : 2000 QA-Nr.: 041002000292 deltadue series DIN rail mounting modules for control and data acquisition S E R I E S Process controllers Temperature controllers Transmitters with alarms I/O

More information

Drawings. Model UT35A Digital Indicating Controller (UT35A-NNN-xx-xx/x) SD 05P01D41-05EN. External Dimensions. Panel Cutout Dimensions.

Drawings. Model UT35A Digital Indicating Controller (UT35A-NNN-xx-xx/x) SD 05P01D41-05EN. External Dimensions. Panel Cutout Dimensions. Drawings SD PD-EN Model A Digital Indicating Controller (A-NNN-xx-xx/x) [Style: S] External Dimensions Unit: mm (approx. inch) 96 (.78) (.) 6 (.6) Bracket Terminal cover (.79) 96 (.78) 9.6 (.6) 9.6 (.7).

More information

MIC-2 MKII, Multi-instrument DATA SHEET

MIC-2 MKII, Multi-instrument DATA SHEET MIC-2 MKII, Multi-instrument DATA SHEET Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional)

More information

MRC 7000 Proven Recording Reliability that Became the Industry Standard!

MRC 7000 Proven Recording Reliability that Became the Industry Standard! Data Sheet Recorder//Profiler DESCRIPTION The MRC7000 Recorder/ is a microprocessor based circular chart instrument capable of measuring, displaying, recording and controlling up to two process variables

More information

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current Data sheet SIMATIC S7-1200, CPU 1215C, COMPACT CPU, DC/DC/DC, 2 PROFINET PORT, ONBOARD I/O: 14 DI 24V DC; 10 DO 24V DC 0.5A 2 AI 0-10V DC, 2 AO 0-20MA DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA

More information

eztrend QXe eztrend QXe Features Typical Applications Description Representative photograph, actual product appearance may vary.

eztrend QXe eztrend QXe Features Typical Applications Description Representative photograph, actual product appearance may vary. Datasheet -- Representative photograph, actual product appearance may vary. Due to regional agency approval requirements, some products may not be available in your area. Please contact your regional Honeywell

More information

Master Panel. Specifications. Document No. TS-2010 February 15, Product Description. Sample Specification

Master Panel. Specifications. Document No. TS-2010 February 15, Product Description. Sample Specification SCC Inc. Master Panel Product Description February 15, 2017 The Master Panel shall provide lead/lag control and time based, automatic rotation of up to eight (8) boilers, when used in conjunction with

More information

Yokogawa YS100 Driver PTC Inc. All Rights Reserved.

Yokogawa YS100 Driver PTC Inc. All Rights Reserved. 2016 PTC Inc. All Rights Reserved. 2 Table of Contents 1 Table of Contents 2 3 Overview 3 Device Setup 4 Modem Setup 4 Data Types Description 6 Address Descriptions 7 YS150 Addressing 7 YS170 Addressing

More information

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current Data sheet SIMATIC S7-1200, CPU 1217C, COMPACT CPU, DC/DC/DC, 2 PROFINET PORT ONBOARD I/O: 10 DI 24V DC; 4 DI RS422/485; 6 DO 24V DC; 0,5A; 4 DO RS422/485; 2 AI 0-10V DC, 2 AQ 0-20MA; POWER SUPPLY: DC

More information

Omega and Red Lion team-up!

Omega and Red Lion team-up! Omega and Red Lion team-up! Red Lion History Started in 1972 Sensors and OEM Products Panel Meters started in 1976 Red Lion Today 3 International Sales Offices Over 100,000 Square Feet Full Surface Mount

More information

Wall-/Pipe Mounted Universal Process Indicator

Wall-/Pipe Mounted Universal Process Indicator Data Sheet SS/_8 Wall-/Pipe Mounted Universal Process Indicator High visibility LED display the clearest view of your process status 0.1% measurement accuracy precise indication of process measurement

More information

Yokogawa YS100 Serial Driver Help Kepware Technologies

Yokogawa YS100 Serial Driver Help Kepware Technologies Yokogawa YS100 Serial Driver Help 2012 Kepware Technologies 2 Table of Contents Table of Contents 2 3 Overview 3 Device Setup 4 Modem Setup 5 Data Types Description 7 Address Descriptions 8 YS150 Addressing

More information

XT-9100 Technical Bulletin

XT-9100 Technical Bulletin System 9100 Technical Manual 636.4 Technical Bulletins Section Technical Bulletin Issue Date 0896 XT-9100 Technical Bulletin XT-9100 Extension Module/XP-910x Expansion Modules Page 3 Introduction 3 SX

More information

General Specifications

General Specifications General Specifications GS 34P02Q02-01E FCN-RTU Low Power Autonomous Controller Functions GENERAL This document describes the system configurations, development/maintenance, software configurations, and

More information

Long Term Record Data Saving. Saved Data playback. Math and totalization. Communication Ethernet (10Base-T) is available. (option) Screen saver

Long Term Record Data Saving. Saved Data playback. Math and totalization. Communication Ethernet (10Base-T) is available. (option) Screen saver Type: PHU Long Term Record Data Saving years in Compact Flash (In case of using 5MB Compact Flash) Saved Data playback Saved data in Memory card can be easily called out and played back on display Math

More information

- SELF-TUNING PID ALGORITHM - INTUITIVE COLOR DISPLAY WITH TEXT MESSAGING - UNIVERSAL PROCESS AND TC/RTD INPUTS - MULTI- FUNCTION RAMP- DWELL/PROCESS

- SELF-TUNING PID ALGORITHM - INTUITIVE COLOR DISPLAY WITH TEXT MESSAGING - UNIVERSAL PROCESS AND TC/RTD INPUTS - MULTI- FUNCTION RAMP- DWELL/PROCESS ELK. ETK COMPACT BASIC CONTROL - SELF-TUNING PID ALGORITHM - INTUITIVE COLOR DISPLAY WITH TEXT MESSAGING - UNIVERSAL PROCESS AND TC/RTD INPUTS - MULTI- FUNCTION RAMP- DWELL/PROCESS TIMER - SOFT START OUTPUT

More information

General Specifications

General Specifications General Specifications GS 32P06P10-01EN Models S2BN4D, S2BN5D Base Plates for Barrier (for N-IO) System Models: S2ZN4D, S2ZN5D N-IO I/O Unit GENERAL This General Specifications (GS) provides the specifications

More information

Self-Powered Wireless Instrumentation

Self-Powered Wireless Instrumentation Self-Powered Wireless Instrumentation Accutech Rapid deploy wireless instrumentation solutions for telemetry and remote SCADA Cost-Effective Solutions for Challenging Applications 03 Knowledge of your

More information

2 Device description. 2 Device description 2.1 Function. 2.1 Function. 2.2 Intended use. 2.3 Device versions

2 Device description. 2 Device description 2.1 Function. 2.1 Function. 2.2 Intended use. 2.3 Device versions 2 Device description 2.1 Function 2 Device description 2.1 Function MICRO PANELs can be used as HMI devices or as integrated HMI/PLC devices. 2.2 Intended use MICRO PANELs are primarily used in machine

More information

DINALOG A 144 x 36 A1400 Light-Strip Indicator

DINALOG A 144 x 36 A1400 Light-Strip Indicator DINALOG A x 6 A00 Light-Strip Indicator -9-0-0 /.00 Front panel dimensions: x 6 mm Light-strip indicator with 7 high-contrast LEDs Red LED display color Digital display range for portrait format: 999 to

More information

MIC-2 Multi-instrument DATA SHEET

MIC-2 Multi-instrument DATA SHEET Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional) Profibus DP (optional) I/O modules

More information

Dual Channel Monitor for Measurement of Speed and Ratio with SIL1 requirements Series D224.xx

Dual Channel Monitor for Measurement of Speed and Ratio with SIL1 requirements Series D224.xx D224 Dual Channel Monitor for Measurement of Speed and Ratio with SIL1 requirements Series D224.xx D224 Front View KEY FEATURES SIL1 / IEC 61508:2010 compliant Dual Channel Speed and Ratio Monitor with

More information

D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors

D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors Ron Boe 5/15/2014 This user guide details the servo drives capabilities and physical interfaces. Users will be able to

More information

VR18 FAQs - Frequently Asked Questions

VR18 FAQs - Frequently Asked Questions VR18 FAQs - Frequently Asked Questions Q1: What is the maximum scale low and scale high values we can set in the recorder for the analog inputs and outputs? Q2: What is the maximum distance between PC

More information

Backplane. System integration. Backplane

Backplane. System integration. Backplane Backplane System integration Backplane Backplanes designed for minimum overall life cycle costs Simple, reliable and professional design Using standard cost-optimised DIN-rail devices Flexible connection

More information

ABB Instrumentation. Specifications. COMMANDER 505 Advanced Process Controller

ABB Instrumentation. Specifications. COMMANDER 505 Advanced Process Controller Specifications COMMANDER 505 Advanced Process Controller Multiple PID control capabilities single loop, feedforward, cascade, feedforward with cascade, ratio, auto/manual station, analog backup, heat/cool

More information

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current Data sheet *** SPARE PART*** SIMATIC S7-1200, CPU 1214C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 14 DI 24V DC; 10 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 50 KB General

More information

FloBoss TM 107/107E Flow Manager Overview

FloBoss TM 107/107E Flow Manager Overview FloBoss TM 107/107E Flow Manager Overview New Technology New Features and Benefits. 1of 39 Introducing the FloBoss 107 The FloBoss 107 Flow Manager introduces a new technology platform to the FloBoss family

More information

General Specifications

General Specifications General Specifications Model VP6E5800 Turbomachinery I/O Module Logic Builder Package [Release 6] General Turbomachinery I/O modules are the modules that built-in with the high-speed interlock blocks,

More information

General information. Display. Supply voltage

General information. Display. Supply voltage Data sheet SIMATIC S7-1200, CPU 1212C, COMPACT CPU, DC/DC/RLY, ONBOARD I/O: 8 DI 24V DC; 6 DO RELAY 2A; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 75 KB General information Product

More information

PENKO Engineering B.V. When Weighing Counts FLEX Multi Channel Extended

PENKO Engineering B.V. When Weighing Counts FLEX Multi Channel Extended SPECIFICATIONS FLEX Multi Channel For each individual weighing channel (channel 1-4) Wiring Full Wheatstone bridge with passive connections (6-wire system) Sense system Passive sense system Excitation

More information

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET & DIN, Multi-instrument DATA SHEET Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional)

More information

Flamma BIOMASS COMBUSTION SYSTEM CONTROLLER. Preliminary Description V.1 Santi Moroño / Jose Caldelas / Juan R. Regueiro / 26/02/ :34

Flamma BIOMASS COMBUSTION SYSTEM CONTROLLER. Preliminary Description V.1 Santi Moroño / Jose Caldelas / Juan R. Regueiro / 26/02/ :34 Flamma BIOMASS COMBUSTION SYSTEM CONTROLLER Preliminary Description V.1 Santi Moroño / Jose Caldelas / Juan R. Regueiro 18-02-2013 / This document presents some preliminary ideas for the development of

More information

General Specifications

General Specifications General Specifications GS 34P02Q02-01E FCN-RTU Low Power Autonomous Controller Functions GENERAL This document describes the system configurations, development/maintenance, software configurations, and

More information

General information. Display. Supply voltage

General information. Display. Supply voltage Data sheet SIMATIC S7-1200, CPU 1211C, COMPACT CPU, DC/DC/RELAY, ONBOARD I/O: 6 DI 24V DC; 4 DO RELAY 2A; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 50 KB General information

More information

Digital Indicator Solutions

Digital Indicator Solutions Digital Indicator Solutions Loop-Powered Attachable Compact Attachable Loop-Powered Smart Compact System Loop-Powered Compact Smart System Intelligent Smart System "Intelligent" Options Dual & Display

More information

100mm Process Indicator Recorder

100mm Process Indicator Recorder Data Sheet SS/_3 100mm Process Indicator Recorder One or two pen continuous line 100mm recorder universal input for thermocouple, RTD, mv, ma and V Clear, 5-digit LED display high visibility, wide viewing

More information

6-Channel Monitor. Installation and Operation Manual

6-Channel Monitor. Installation and Operation Manual 3211 Fruitland Ave Los Angeles, CA 90058 Catalyst Monitor 6-Channel Monitor Version 2 Installation and Operation Manual Rev. H P/N145F-12964 PCO - 00009743 (c) Copyright 2015, Barksdale, Inc. All Rights

More information

INSTRUCTION MANUAL STATION CONTROLLER SC1000 MOTOR PROTECTION ELECTRONICS, INC.

INSTRUCTION MANUAL STATION CONTROLLER SC1000 MOTOR PROTECTION ELECTRONICS, INC. INSTRUCTION MANUAL STATION CONTROLLER SC1000 MOTOR PROTECTION ELECTRONICS, INC. 2464 Vulcan Road, Apopka, Florida 32703 Phone: (407) 299-3825 Fax: (407) 294-9435 Revision Date: 9-11-08 Applications: Simplex,

More information

General information. Engineering with. Supply voltage. Load voltage L+ Input current. Power losses. Memory. Work memory.

General information. Engineering with. Supply voltage. Load voltage L+ Input current. Power losses. Memory. Work memory. Product data sheet SIMATIC S7-300, CPU 314C-2DP COMPACT CPU WITH MPI, 24 DI/16 DO, 4AI, 2AO, 1 PT100, 4 FAST COUNTERS (60 KHZ), INTEGRATED DP INTERFACE, INTEGRATED 24V DC POWER SUPPLY, 64 KBYTE WORKING

More information

General Specifications

General Specifications General Specifications YSS1000 Setting Software GENERAL The YSS1000 setting software (hereinafter referred to as the YSS1000) is package software to configure the functions of the YS1000 series (hereinafter

More information

Redundant System Redundant System P9-1-1

Redundant System Redundant System P9-1-1 .. P-- Overview - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - P-- idcs-8830/idcs-8830r - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

More information

Data sheet CC 03, Commander Compact (603-1CC21)

Data sheet CC 03, Commander Compact (603-1CC21) Data sheet CC 03, Commander Compact (603-1CC21) Technical data Order. Type 603-1CC21 CC 03, Commander Compact General information Note - Features Display: 2 x 20 characters Interface: MP²I User memory:

More information

Controller module. Brief description. Features. Block structure. Page 1/7. Data Sheet

Controller module. Brief description. Features. Block structure. Page 1/7. Data Sheet JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net

More information

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current Data sheet SIMATIC S7-1200, CPU 1214C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 14 DI 24V DC; 10 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 100 KB General information Firmware

More information

MICRO SERIES PROCESS DISPLAYS LARGE DIGIT MODELS

MICRO SERIES PROCESS DISPLAYS LARGE DIGIT MODELS The MICRO SERIES PROCESS DISPLAYS LARGE DIGIT MODELS Mighty-5 DPM MODELS Micro-P & Mighty-1 Mighty-1 Micro-P ELECTRO-NUMERICS, INC. Introduction The Electro-Numerics family of Digital Panel Meters and

More information

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current Data sheet SIMATIC S7-1200, CPU 1215C, COMPACT CPU, DC/DC/DC, 2 PROFINET PORT, ONBOARD I/O: 14 DI 24V DC; 10 DO 24V DC 0.5A 2 AI 0-10V DC, 2 AO 0-20MA DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA

More information

PR Series Paperless Recorders

PR Series Paperless Recorders PR Series Paperless Recorders Head Office: Brainchild Electronic Co., Ltd. 209 Chongyang Road, Nangang Dist., Taipei 11573, Taiwan Tel: +886-2-2786-1299 Fax: +886-2-2786-1395 Website: www.brainchild.com.tw

More information

Y800 Plus Frequency, Rate & Period Meter With dual, independently field-scalable channels

Y800 Plus Frequency, Rate & Period Meter With dual, independently field-scalable channels Y800 Plus Frequency, Rate & Period Meter With dual, independently field-scalable channels Description Features Frequencies from 0.005 Hz to 1 MHz 6-digit resolution at update rates up to 25/s Selectable

More information