Manual for Connection and Operation of G I A 1 0 N. Version: 3.0

Size: px
Start display at page:

Download "Manual for Connection and Operation of G I A 1 0 N. Version: 3.0"

Transcription

1 GIAN - Manual for connection and operation Version:. Page Manual for Connection and Operation of G I A N Version:. In accordance with EN- and EN- for unresetricted use in housing an industrial areas We reserve the right to make technical changes GREISINGER electronic Hans-Sachs-Straße D- Regenstauf Telefax ()

2 GIAN - Manual for connection and operation Version:. Page I N D E X. Safety regulations... page. Introduction... page. Electric connection... page. Terminal assignment... page. Connection data... page. Wiring of input signal... page.. Wiring of a to ma measuring transducer in -wire technology... page.. Wiring of a () to ma measuring transducer in -wire technology... page.. Wiring of a to () Volt measuring transducer in -wire technology... page.. Wiring of a to () Volt measuring transducer in -wire technology... page.. Wiring of a Pt or KTY- temperature sensor... page.. Wiring of a frequency signal... page.. Wiring of a count signal... page. Wiring of switching outputs... page. Wiring of several compact indicators... page. Input configuration... page. Selection of input signals... page. Standard signals to ma, to ma, to Volt and to Volt... page. Temperature sensor KTY- and Pt... page. Frequency measuring... page. Upwards/downwards counter... page. Output configuration... page. Setting of output function... page. Two-level controller, three-level controller... page. Min./max. alarm... page. Two-level controller with min./max. alarm... page. RS Interface... page. Interface configuration... page. Data transfer format... page. Data transfer processing protocol... page. Description of characters used... page. Functional code... page. Data format... page. Availability... page. GIAN - digital display only... page. Digital display mode... page. Digital display mode... page. Malfunction codes... page. Specification... page. Examples... page. Two-level humidity controller with min./max. alarm... page GREISINGER electronic Hans-Sachs-Straße D- Regenstauf Telefax ()

3 GIAN - Manual for connection and operation Version:. Page. Safety Regulations In order to exclude any risk whatsoever for the operator the following points have to be observed : a) Immediately switch off the unit in case of visible damage or obvious malfunctions. b) Make it a rule to always disconnect voltage source and unit befor opening it up. The entire unit and its connection have to be fingerproof after installation. c) Standard regulations for operation and safety for electrical, light and heavy current equipment have to be observed, with particular attention having to be paid to national safety regulations (e.g. VDE ). d) When connecting the unit to other units (e.g. PC) the interconnection has to be designed most thoroughly as internal connections in third-party units (e.g. connection GND with protective earth) may lead to undesired voltage potentials. Attention: When running electric devices, parts of these will always be highly energised. Unless the warnings are observed serious personal injuries or damage to property may result. Skilled personnel only should be allowed to work with this unit. For trouble-free and safe operation of the unit please ensure professional transport, storage, installation and connection as well as proper operation and maintenance. Skilled personal are persons familiar with installation, connection, commissioning, and operation of the product and have professional qualification relating to their job. For example: Trainig or instruction and/or qualification to switch on/off, isolate, ground and mark electric circuits and devices/systems. Training or instruction according to the state of the art of safety technology to maintain and operate safety equipment. First-aid trainig. GREISINGER electronic Hans-Sachs-Straße D- Regenstauf Telefax ()

4 GIAN - Manual for connection and operation Version:. Page. Introduction Our compact indicator GIA N is a microprocessor controlled display, supervision and control unit for universal applications. There are connections for four standard signals ( to ma to ma, to Volt and to Volt), two temperature sensors (KTY- and Pt), frequency measuring and counter functions. In addition, two switching outputs are available, which can be configurated as two-level controller, three-level controller, two-level controller with min./max. alarm, common or individual min./max. alarm. Furthermore, the unit is equipped with a standard RS interface, thus allowing communication with a host computer. When leaving our factory the compact indicator has been subjected to various inspection tests and is completely calibrated. Before it can actually be used, the compact indicator will have to be configurated for customer's application. Please proceed as follows: button button button To remove front plate: turn carefully with screw driver V V- / Dig. GND Output Output Freq. / Counter ma - ma / V / KTY / Pt...V / KTY / Pt...V A B RS RS GIA N connect compact indicator completely (see chapter 'Electric connection'). remove red front plate (see sketch). switch on supply voltage and wait for segment test to be completed. adjust compact indicator to the input signal required proceeding as per chapter 'Input configuration'. set compact indicator outputs according to the directions given in chapter 'Output configuration'. red front plate to be snapped back on GREISINGER electronic Hans-Sachs-Straße D- Regenstauf Telefax ()

5 GIAN - Manual for connection and operation Version:. Page. Electric connection Wiring and commissioning of the unit must be carried out by trained personnel. Wrong wiring may lead to the destruction of the GIAN, in which case we cannot assume any warranty... Terminal assignment.. Connection data Supply voltage Input ma Input -V Input -V Switching output a. Frequency/counter input Supply voltage Uv (- V DC) Supply voltage -Uv / GND Switching output Switching output Frequency input / counter input Input ma Input GND Input -V Input -V A B RS interface between terminals and a., a. and and and and min V ma V V <.V typ. max V V ma ma V V >.V Limitations min V V ma -.V -V -. max V V ma ma V V V V V- / Dig. GND Output Output Freq. / Counter ma - ma / V / KTY / Pt...V / KTY / Pt...V A B RS RS Notes DC voltage DC voltage GIA N Before connection of the unit, please make sure that the permissible voltage and current values will not be exceeded.. Wiring of input signal.. Wiring of a to ma measuring transducer in -wire technoloy - VDC Mains supply: - VDC Uv -Uv -ma transmitter for transmitter Uv -Uv -ma transmitter with individual transmitter supply without individual transmitter supply GREISINGER electronic GmbH Hans-Sachs-Straße D- Regenstauf Telefax ()

6 GIAN - Manual for connection and operation Version:. Page... Wiring of a () to ma measuring transducer in -wire technology - VDC - VDC Uv ()-ma Sig. transmitter -Uv for transmitter Uv Sig. -Uv ()-ma transmitter with individual transmitter supply without individual transmitter supply... Wiring of a to () Volt measuring transducer in -wire technology Uv Sig. -Uv - VDC -()V transmitter V V for transmitter V V Uv Sig. -Uv - VDC -()V transmitter... Wiring of a to () Volt measuring transducer in -wire technology with individual transmitter supply - VDC Uv Sig -()V Sig- transmitter Uv Sig -()V Sig- transmitter -Uv V V for transmitter with individual transmitter supply without individual transmitter supply... Wiring of a Pt or KTY- temperature sensor V V -Uv - VDC Pin, of the GIA are internal connected. => -Uv and Sig- get connected! without individual transmitter supply - VDC - VDC Pt colou rless red Attention: observe polarity KTY- Pt temperature sensor KTY- temperature sensor GREISINGER electronic GmbH Hans-Sachs-Straße D- Regenstauf Telefax ()

7 GIAN - Manual for connection and operation Version:. Page... Wiring of a frequency signal - VDC - VDC Uv frequency Sig. generator GND Uv Sig. GND frequency generator for transm itter with individual frequency generator supply without individual frequency generator supply RV... Wiring of a counter signal Uv Sig. GND - VDC transducer e.g. flow transducer: Vision; GH, etc. please check if reverse-connect protection is required Connection of a transducer with open collector output resetting button - VDC Uv pulse Sig. generator GND GIAN nr. Uv Sig. GND - VDC pulse generator Manual resetting with external button - VDC GIAN nr. k at -V k at -V resetting button Uv Sig. GND pulse generator Cascading of GIAN Automatic resetting via output, additionally manual resetting with external button GREISINGER electronic GmbH Hans-Sachs-Straße D- Regenstauf Telefax ()

8 GIAN - Manual for connection and operation Version:. Page.. Wiring of switching outputs Both switching outputs of the GIAN are designed as open collector transistor outputs. In the active mode the signal (switching output on) existing at the switching output will be switched reversely to the negative pole of the supply voltage (connection ). If an output is configurated for alarm, it will be 'on' as long as in idle state (no alarm). In case of an alarm condition being fulfilled, the output transistor will 'open'. Please note that the max. permissible voltage of Volt and the max. switching current of ma must not be exceeded (not even for a short time). Especially when switching inductive loads (e.g. relays, coils etc,) protective arrangements to limit voltage peaks have to be taken. When switching large capacitive loads the making current will have to be limited to the permissible amperage by connecting a series resistor or a current limiter. The same applies to incandescent lamps, whose making current is also quite high due to their low cold resistance. Relay Relay - VDC Voltage limitation with freewheeling diode (e.g. N) Connection of relay - - VDC Connection of audible piezo alarm and lamp k - VDC Uin semiconductor relay. Wiring of several GIAN Input and outputs of the GIAN as well as the RS interface are not electrically isolated. If several GIAN will be interconnected you have to make sure to avoid accidental energization. Make sure to observe the following points : Connection of a semiconductor relay If several GIAN are supplied by one supply voltage source, the sensors, measuring transducers etc. have to be electrically isolated. If the sensors, measuring transducers etc. cannot be electrically isolated, the GIAN will have to be operated with electrically isolated supply voltage sources. Please note, that an electric connection may also be created via the media to be measured (e.g. ph-electrode and conductivity electrode in liquid). If the GIAN units are connected via the RS interface, the sensors, measuring transducers etc. will have to be electrically isolated. If the compact indicators are supplied from one voltage source, the accidental energization (-Uv to -Uv) must not exceed Volt. GREISINGER electronic GmbH Hans-Sachs-Straße D- Regenstauf Telefax ()

9 GIAN - Manual for connection and operation Version:. Page. Input configuration. Selection of input signal Commission digital display and wait for segment test to be completed. Press button (e.g. using small screw driver). INP ('INPUT') will be displayed. button button button Select input signal by pressing button or button (left-hand respectively centre button). Display Input signal to ma Also refer to chapter. to ma. to Volt. to Volt. KTY- temperature sensor. Pt - temperature sensor. frequency. upwards counter. downwards counter. digital display mode (only selectable by interface) digital display mode (only selectable by interface).. Acknowledge signal selected by pressing button. Display shows INP again. Depending on the input signal selected, additional inputs will be required. Please proceed as per the instructions given in chapter. for to ma, to ma, to Volt or to Volt; chapter. for KTY or Pt; chapter. for frequency and chapter. for upwards or downwards counter. GREISINGER electronic GmbH Hans-Sachs-Straße D- Regenstauf Telefax ()

10 GIAN - Manual for connection and operation Version:. Page.. Standard signals to ma, to ma, to Volt and to Volt This chapter describes the GIAN configuration for standard signals. The following instructions are based on the assumption that an input signal, ie to ma, to ma, to Volt or to Volt has been selected according to the directions given in chapter.. The display shows INP. Press button, display shows dp (decimal point). Select desired place for decimal point by pressing buttons and button button button Display Number of places after decimal point Example Acknowledge position of decimal point by pressing button. Display shows dp again. After pressing button again, the display will show the input signal set ( to, to, to or to ) with the left-hand figure flashing. or or or Use buttons and to enter the value to be displayed for an input signal of ma, ma or respectively Volt. Rolling function: Buttons and are equipped with a rolling function for entering values. Short pressing of the buttons increases (button ) respectively decreases (button ) value by one digit. After pressing of the buttons (>s) for an extended time the values start counting up or downwards, with the counting speed being increased after s. Acknowledge value displayed by pressing button. The display will show the input signal again. Switch over to next parameter by pressing button once again. The display will continue showing the input signal selected with both right-hand figures flashing. or or or Via buttons and you may now enter the value to be displayed on the GIAN for either one of the following input signals: ma, Volt or Volt. Acknowledge value set by pressing button. The display will show the input signal again. GREISINGER electronic GmbH Hans-Sachs-Straße D- Regenstauf Telefax ()

11 GIAN - Manual for connection and operation Version:. Page Press button once again. The display will show LI (Limit). Use buttons and to select desired measuring range limitation. Display Measuring range limitation Application The measuring range limits ard approx. % over/under the standard signal set. Measuring range is exactly limited to the desired standard signal. Standard setting Acknowledge selection by pressing button. The display will show LI again. Press button once again. The display will show FILt (Filter). Select desired input filter, or with buttons and. In case signals above/below the standard signal range result in errorneous display values: Examples rel. humidity > % ph-value < ph Display Filter range Delay in display Notes off on on approx.. seconds approx.. seconds If no valid measuring values can be found, an "average value" of the latest measuring series will be displayed. If no valid measuring values can be found the fault message FE will be displayed. Acknowledge by pressing button once again. The display will show FILt again. Press button once again. The display will show nr (Number). Use buttons and to enter the address numbers for accessing the GIAN in a data communication network. For more detailed information please refer to chapter 'RS-interface'. If you do not intend to use the RS interface, please disregard and skip both this point and the following one. Acknowledge your input by pressing button. The display will show nr again. You have now completed setting up and adjusting of your GIAN to your measuring transducer. Please proceed to the next step of commissioning, i.e. configuration of the GIAN outputs as described in chapter. GREISINGER electronic GmbH Hans-Sachs-Straße D- Regenstauf Telefax ()

12 GIAN - Manual for connection and operation Version:. Page. Temperature sensor KTY- and Pt This chapter describes the configuration of the GIAN for direct connection of a temperature sensor type KTY- or Pt. The following instructions are based on the assumption that you have selected input signal KTY or Pt as described in chapter.. The display should show INP. Press button, the display will show OFFS (Offset). Set offset value (zero offset) with buttons and. We recommend that the offset value be set to. respectively. button button button The offset value offers the possibility of correcting display faults resulting from very long and thin connecting lines respectively sensor tolerances. The value input here will be subtracted from the measuring result (offset of characteristic curve parallel to zero value). Acknowledge offset value by pressing button. The display will show OFFS again. Press button once again. The display will show FILt (Filter). Select desired input filter, or with buttons and. Display Filter state Delay in display Notes off on approx.. seconds If no valid measuring values can be found, an "average value" of the latest measuring series will be displayed. on approx.. seconds If no valid measuring values can be found the fault message FE will be displayed. Acknowledge by pressing button once again. The display will show FILt again. Press button once again. The display will show nr (Number). Use buttons and to enter the address numbers for accessing the GIAN in a data communication network. For more detailed information please refer to chapter 'RS-interface' If you do not intend to use the RS interface, please disregard and skip both this point and the following one. Acknowledge your input by pressing button. The display will show nr again. You have now completed setting up and adjusting of your GIAN to your measuring transducer. Please proceed to the next step of commissioning, i.e. configuration of the GIAN outputs as described in chapter. GREISINGER electronic GmbH Hans-Sachs-Straße D- Regenstauf Telefax ()

13 GIAN - Manual for connection and operation Version:. Page. Frequency measuring This chapter describes the configuration of the GIAN when used for frequency measuring. The following instructions are based on the assumption that you have selected input signal 'frequency' as described in chapter.. The display should show INP. Press button, the display will show dp (decimal point). Select position of decimal point as desired by pressing buttons and. button button button Display Number of places after decimal point Example Acknowledge position of decimal point by pressing button. The display will show dp again. Press button, the display will show Fr.An., with Fr (frequency) flashing. Enter highest frequency value to be measured by pressing buttons and. Rolling function: Buttons and are equipped with a rolling function for entering values. Short pressing of the buttons increases (button ) respectively decreases (button ) value by one digit. After pressing of the buttons for an extended time (>s) the values start counting up or downwards, with the counting speed being increased after s. Acknowledge input with button. The display will show Fr.An. again. Press button once again. The display continues showing Fr. An., with An (Anzeige=display) flashing. Use buttons and to enter value to be displayed on the GIAN for the highest possible frequency set before. Acknowledge value to be displayed by pressing button. The display will show Fr.An. again. Press button once again. The display will show LI (Limit). Select desired limitation of measuring range by pressing buttons and. GREISINGER electronic GmbH Hans-Sachs-Straße D- Regenstauf Telefax ()

14 GIAN - Manual for connection and operation Version:. Page Display Measuring range limitation Frequencies up to khz will be measuredl Frequencies exceeding the highest possible frequency set will result in erroneous displays. Application Standard setting In case signals exceed the highest frequency this will result in erroneous display values: Examples: rel. humidity > % Acknowledge selection by pressing button. The display will show LI again. Press button once again, the display will show FILt (Filter). Select desired input filter, or by pressing buttons and. Display Filter state Delay in display Notes off on approx.. seconds If no valid measuring values can be found, an "average value" of the latest measuring series will be displayed. on approx.. seconds If no valid measuring values can be found the fault message FE will be displayed. Acknowledge by pressing button once again. The display will show FILt again. Press button once again. The display will show nr. Use buttons and to enter the address numbers for accessing the GIAN in a data communication network. For more detailed information please refer to chapter 'RS-interface'. If you do not intend to use the RS interface, please disregard and skip both this point and the following one. Acknowledge your input by pressing button. The display will show nr again. You have now completed adjusting of your GIAN to the measuring transducer. Please proceed to the next step of commissioning, i.e. configuration of the GIAN outputs as described in chapter. GREISINGER electronic GmbH Hans-Sachs-Straße D- Regenstauf Telefax ()

15 GIAN - Manual for connection and operation Version:. Page. Upwards/downwards counter This chapter describes the configuration of the GIAN when used as counter. The following instructions are based on the assumption that you have selected input signal 'upwards counter' (Co.uP) or 'downwards counter' (Co.dn) as described in chapter.. The display should show INP. Press button, the display will show dp (decimal point). Select position of decimal point as desired by pressing buttons and. button button button Display Number of places after decimal point Example Acknowledge position of decimal point by pressing button. The display will show dp again. Press button, the display will show SCAL (scaler). Set desired scaler value ( to ) by pressing buttons and. Rolling function: Buttons and are equipped with a rolling function for entering values. Short pressing of the buttons increases (button ) respectively decreases (button ) value by one digit. After pressing of the buttons for an extended time (>s) the values start counting up or downwards, with the counting speed being increased after s. The pulses received at the input will be divided by the scaler value before being evaluated by the GIAN. The GIAN is able to process a maximum number of pulses directly. By entering a corresponding scaler value pulse frequencies of up to pulses (= pulse/s *) can be displayed. The GIAN counter ranges from to pulses. By means of the scaler this range can be extended to up to pulses (*). Coarse scaling of the GIAN is also facilitated by the scaler value. Example: A flow sensor emits pulses per litre. By entering a scaler value of one pulse per litre will be transferred to the GIAN for evaluation. If possible, we recommend setting a scaler value above, as this will render the compact indicator unit more insensitive to high frequency interference signals. Acknowledge scaler value by pressing button. The display will show SCAL again. GREISINGER electronic GmbH Hans-Sachs-Straße D- Regenstauf Telefax ()

16 GIAN - Manual for connection and operation Version:. Page Press button, the display will show "CoAn", with Co (counter) flashing. Use buttons and to set - max. number of pulses to be counted (for upwards counter). - number of pulses as of which to start downwards counting (for downwards counter). A value of has to be set for the required number of pulses from to. Please note: At this point set number of pulses to be transferred to the GIAN after the scaler. In order to calculate overall number of pulses, this value has to be multiplied by the scaler value set. Acknowledge input by pressing button once again. The display will show Co.An again. Press button once again. The display will continue showing Co.An, with An (display) flashing. Use buttons and to enter the value to be displayed by the GIAN for any preselected number of pulses. Acknowledge display value by pressing button. The display will show Co.An again. Press button once again. The display will show LI (Limit). Select desired limitation of measuring range by pressing buttons and. Display Measuring range limitation Frequencies up to khz will be measuredl Frequencies exceeding the highest possible frequency set will result in erroneous displays. Application Standard setting In case signals exceed the highest frequency this will result in erroneous display values: Examples: rel. humidity > % Acknowledge selection by pressing button. The display will show LI again. You have now completed adjusting of your GIAN to the measuring transducer. Please proceed to the next step of commissioning, i.e. configuration of the GIAN outputs as described in chapter. GREISINGER electronic GmbH Hans-Sachs-Straße D- Regenstauf Telefax ()

17 GIAN - Manual for connection and operation Version:. Page. Output configuration The switching outputs of the GIAN must never be configurated prior to the configuration of the input (please refer to chapter ).. Setting of output function Commission GIAN and wait for segment test to be completed. Press button till outp ('Output') will be displayed. Select desired output function by pressing buttons and. button button button Display Description no function, used as display only Function Output Output continue with chapter -level controller digital -level controller common min./max. alarm min. and max. alarm level controller digital -level controller digital -level controller. -level controller with min./max. alarm min. and max. alarm digital -level controller. individual min./max. alarm max. alarm min. alarm. Acknowledge output function selected by pressing button. The display will show outp again. Depending on the output signal selected, the various making/breaking points respectively min./max. alarm limits will have to be entered. Please proceed as per the instructions given in chapter. for -level controller. chapter. for common min./max. alarm. chapter. for -level controller. chapter. for -level controller with min./max. alarm. chapter. for individual min./max. alarm. If you have not selected any function, the configuration of the GIAN is now completed. Press button to switch over to display of measuring value. GREISINGER electronic GmbH Hans-Sachs-Straße D- Regenstauf Telefax ()

18 GIAN - Manual for connection and operation Version:. Page.. -level controller, -level controller This chapter describes the setting of the making points when using the GIAN as digital - level controller or -level controller. The following instructions are based on the assumption that you have selected output function '-level controller' or '-level controller' as described in chapter.. The display should show outp. Press button, the display will show I.on (making point of output ). Use buttons and to set value at which output is to be made. Rolling function: Buttons and are equipped with a rolling button button button function for entering values. Short pressing of the buttons increases (button ) respectively decreases (button ) value by one digit. After pressing of the buttons for an extended time (>s) the values start counting up or downwards, with the counting speed being increased after s. Acknowledge making point set by pressing button. The display will show I.on again. Press button once again, the display will show I.oFF (breaking point of output ). Use buttons and to set value at which output is to be broken. Acknowledge value by pressing button. The display will show I.oFF again. If you have selected the '-level controller' function the configuration of the GIAN is now completed. Press button once again to switch over to display of measuring value. If you have selected the '-level controller' function, please proceed as follows: Press button. The display will show.on (making point of output ). Use buttons and to set making point of output. Acknowledge by pressing button. The display will show.on again. Press button once again. The display will show.off (breaking point of output ). Use buttons and to set breaking point. Acknowledge breaking point by pressing button. The display will show.off again. The configuration of the GIAN is now completed. Press button once again to switch over to display of measuring value. GREISINGER electronic GmbH Hans-Sachs-Straße D- Regenstauf Telefax ()

19 GIAN - Manual for connection and operation Version:. Page.. Min./max. alarm This chapter describes the setting of the making points when using the GIAN for min./max. value monitoring. The following instructions are based on the assumption that you have selected output function 'common min./max. alarm' or 'individual min./max. alarm' as described in chapter.. The display should show outp. Press button, the display will show AL.HI (max. alarm limit). Use buttons and to set max. alarm limit. Rolling function: Buttons and are equipped with a rolling button button button function for entering values. Short pressing of the button increases (button ) respectively decreases (button ) value by one digit. After extended pressing of the buttons (>s) the values start counting up or downwards, with the counting speed being increased after s.. Acknowledge alarm limit set by pressing button. The display will show AL.HI. again. Press button once again. The display will show AL.Lo (min. alarm limit). Use buttons and to set minimum alarm limit. Acknowledge by pressing button. The display will show AL.Lo again. Press button once again. The display will show dela (alarm delay). Use buttons and to set alarm delay. The value displayed corresponds to the delay time in minutes. Acknowledge delay set by pressing button. The display will show dela again. The configuration of the GIAN is now completed. Press button once again to switch over to display of measuring value. GREISINGER electronic GmbH Hans-Sachs-Straße D- Regenstauf Telefax ()

20 GIAN - Manual for connection and operation Version:. Page.. -level controller with min./max. alarm This chapter describes the setting of the making points when using the GIAN as digital - level controller with min./max. alarm. The following instructions are based on the assumption that you have selected output function '-level controller with min./max. alarm' as described in chapter.. The display should show outp. Press button, the display will show.on (making point of output ). Use buttons and to set making point of output. Rolling function: Buttons and are equipped with a rolling function for entering values. Short pressing of the button increases button button button (button ) respectively decreases (button ) value by one digit. After extended pressing of the buttons (>s) the values start counting up or downwards, with the counting speed being increased after s. Acknowledge making point by pressing button. The display will show.on again. Press button once again. The display will show.off (breaking point of output ). Use buttons and to set breaking point of output. Acknowledge breaking point by pressing button. The display will show.off again. Press button. The display will show AL.HI (max. alarm limit). Use buttons and to set max. alarm limit. Acknowledge alarm limit set by pressing button. The display will show AL.HI again. Press button once again. The display will show AL.Lo (minimum alarm limit). Use buttons and to set min. alarm limit Acknowledge by pressing button. The display will show AL.Lo. again Press button once again. The display will show dela (alarm delay). Use buttons and to set alarm delay. The value displayed corresponds to the delay time in minutes. Acknowledge delay set by pressing button. The display will show dela again. The configuration of the GIAN is now completed. Press button once again to switch over to display of measuring value. GREISINGER electronic GmbH Hans-Sachs-Straße D- Regenstauf Telefax ()

21 GIAN - Manual for connection and operation Version:. Page. RS - interface The serial interface of the GIAN allows communication of the unit with a host computer. Data polling and transfer is done in the master/slave mode, ie the GIAN will only transmit data upon request. A separate unit address can be attributed to each GIAN. Addresses to are implemented. The GIAN will only respond if requested to do so by the host, provided the unit number of the request string corresponds to the one set (The GIAN will respond within to ms after the end of the request). This method as well as the fact that the interface operates in the half-duplex mode ensure that up to devices can be called via only one - wire line... Interface configuration Type Transfer mode Connection Connecting cable.. Data transfer format RS half-duplex -pin screw/plug-in connection -pin, twisted baud start bit data bits no parity bit stop bit Communication is entirely achieved by means of printable ASCII code... Data transfer processing protocol Request data from GIAN: Request string to GIAN Byte! Nr. Nr. F F / Response from GIAN # F F $ D D D D / Byte Send data to GIAN: Send sting to GIAN! Nr. Nr. # F F $ D D D D / Byte Response from GIAN # a / if data have been successfully taken over Byte GREISINGER electronic GmbH Hans-Sachs-Straße D- Regenstauf Telefax ()

22 GIAN - Manual for connection and operation Version:. Page.. Description of characters used:! : ASCII code: H his character interrupts a connection, if any is existing, and resets all GIAN connected to their original state thus initialising a check to ensure that the following two characters correspond to their respective unit numbers. Nr. : Permissible area "" to "" and "A" to "F" (corresponding to ASCII code H to H and H to H) As a precaution unit number will be transmitted twice. Data will not be processed by the GIAN unless the unit number transmitted is identical to the one set in the respective GIAN. If numbers are not identical the unit will only check if the data stream contains another "!" character thus indicating a new data circuit. F,F : Permissible range see table Functional codes, specifying the parameter and/or value to be processed. For assignments please refer to table of chapter. 'functional code'. / : ASCII code: FH Indicates the end of a data transfer process. Each data transfer process, either from host to GIAN or from GIAN to host is completed by putting "/". # : ASCII code: H Indicates the beginning of a data transfer process. '#' is issued by the GIAN prior to starting transfer of data to the host. If the character '#' is transferred by the host after issuing of the unit number, the GIAN will know that data are to be transferred from the host to the GIAN (programming of GIAN). $ : ASCII code: H Signals that the data following will be transferred in hexadecimal code. D..D : Permissible range '' to '' and 'A' to 'F'. (corresponding to ASCII code H to H and H to H) Data will be presented in the hexadecimal mode. For more detailed information please refer to chapter. 'Data formats'. a : ASCII code: H transferred as hand-shake signal by the GIAN after successful data input to the memory. GREISINGER electronic GmbH Hans-Sachs-Straße D- Regenstauf Telefax ()

23 GIAN - Manual for connection and operation Version:. Page.. Functional code The value (parameter) to be read respectively re-programmed is specified by two bytes, designed F and F in the data transfer protocol. Table illustrates the assignment of functional code and value (parameter) as well as of the correspondingly vlaid data format. It is vital to ensure that only those functional codes and their permissible data as stated in table are transmitted to the GIAN as otherwise internal settings of the unit could be changed. Parameter resp. value ASCII character ASCII code Data format F F F F Display value H H System state H H Input signal H H Position of decimal point H H Scaler for counter function H H Display value for ma, ma resp. Volt, highes t frequency to be measured, max. number of pulses H H Display value for ma, Volt resp. Volt, display value for max. frequency, display value for max. number of pulses H H Limitation of measuring range H H Filter A H H Unit address B H H Output prompt C H H Making point, switching output D H H Breaking point, switching output E H H Making point, switching output F H H Breaking point, switching output H H Max. alarm limit H H Min. alarm limit H H Alarm delay H H Table GREISINGER electronic GmbH Hans-Sachs-Straße D- Regenstauf Telefax ()

24 GIAN - Manual for connection and operation Version:. Page.. Data format General information: The four bytes termed D to D in the data transfer protocol represent the parameter value specified by F and F. The value is represented in hexadecimal printable ASCII characters. The GIAN treats all values as bit words, which means that a range of values from - to and correspondingly a range from H to FFFH can be displayed. The following data bytes contain the bits mentioned above: D equalising Bit to D equalising Bit to D equalising Bit to D equalising Bit to Examples: Value decimal hex ASCII character D D D D ASCII code D D D D H H H H H - FFFFH F F F F H H H H - FH F H H H H FH F H H H H - FFCH F F C H H H H H H H H H Data format : Data format corresponds to the general data format. It is only the range of values that is limited to the display range of - to equalising FH to FH. The decimal point will not be considered. The decimal point position can be called up separately. Data format : This format is used to call up and reset the system state. Data bytes D to D contain information regarding the alarm and fault state of the unit. The assignment is as follows: Data byte D: Bit = : Fault FE active Bit = : Fault FE active Bit = : Fault FE active Data byte D: Bit = : Fault FE active Bit = : Fault FE active Data byte D: Bit = : max. alarm Bit = : min. alarm Bit = : alarm GREISINGER electronic GmbH Hans-Sachs-Straße D- Regenstauf Telefax ()

25 GIAN - Manual for connection and operation Version:. Page Data format : This format is used to call up and program the input signal. The assignment is as follows: : Current input to ma : Current input to ma : Voltage input to Volt : Voltage input to Volt : Resistance input KTY- : Resistance input Pt : Frequency input : Upwards counter : Downwards counter : Digital indicator: mode (only selectable by interface) : Digital indicator: mode (only selectable by interface) Data format : This format is used to call up and/or program the position of the decimal point. The assignment is as follows: : no decimal point : decimal point after digits () : decimal point after digits () : decimal point after digits () Data format : This format is used to call up and program the scaler for the counter function. The scaler can be set to a value between and. Data format corresponds to the general data format. It is only the range of values that is limited to the permissible scaler range of to equalising H to FFH. Data format : This format is used to program the limitation of the measuring range: The assignment is as follows: : extended measuring range limits (LI = ) : narrow measuring range limits (LI = ) Data format : This format is used to call up and program the filter: The assignment is as follows: : filter off (FILt = ) : filter on with "calculation of average value" (FILt = ) : filter on with FE message being active (FILt = ) GREISINGER electronic GmbH Hans-Sachs-Straße D- Regenstauf Telefax ()

26 GIAN - Manual for connection and operation Version:. Page Data format : This format is used to program the unit address. Permissible addresses range from to. Data format corresponds to the general data format. It is only the range of values that is limited to the permissible unit addresses from to equalising H to FH. Data format : This format is used to call up and program the output configuration application: The assignment is as follows: : no output active, unit used as display only : -level controller : common min./max. alarm : -level controller : -level controller with alarm : individual min./max. alarm Data format : This format is used to call up and/or program the alarm delay time. The delay time programme range is to minutes. Data format corresponds to the general data format. It is only the range of values that is limited to the permissible delay time of to minutes equalising H to H. Data format : corresponds to the general data format... Availability The RS interface cannot be used if the compact indicator is configurated as upwards or downwards counters. When used in connection with the frequency measuring function, the following limitations have to be taken into account: Any data exchange whatsoever at the RS input of the GIAN, will interrupt the frequency measuring. The display will continue to show the value measured last. In case of the data exchange lasting for some time, the display will show the fault code FE, thus signalling that frequency measuring has been interrupted. In order to allow frequency measuring and data communication to take place simultaneously, a break of at least s will have to be introduced between two data request/transfer. GREISINGER electronic GmbH Hans-Sachs-Straße D- Regenstauf Telefax ()

27 GIAN - Manual for connection and operation Version:. Page. GIAN - digital display only The GIAN unit is equipped with the "no " and "no " functions. In this mode the GIAN is a display unit only, no measurements are taken. Please note that the "no " and/or "no " functions can only be activated via the RS - interface and cannot be set via the keys located at the unit... Digital display mode : In this mode the value transmitted via the interface is displayed. Please note: The display value and decimal point position will be transmitted separately (see data format and/or )... Digital display mode : This mode can be used to call up the display elements of the GIAN unit directly. In addition a blinking mode can be activated for each of the display elements individually. The segment information is transferred via the two F/F-Codes "" (H, H) and "" (H, H). As the GIAN works with ASCII-Codes only it is possible to transmit segment informations ( bit) per F/F-Code. To control the segments of the display two F/F-Codes are required. First of all send Code "" prior to sending Code "". Sending of "" freezes' the display value. By sending "" the value is made available for the display. Please refer to the opposite table for the segment assignment. In addition to controlling the individual segments the blinking mode can be activated for each of the four -segment displays. Use the F/F-Codes "" to activate and deactivate the blinking mode. By sending of "" the value will be made available for the display simultaneously. F/F code Data byte D D D D D D D Bit a f g e d b c dp segment e segment d segment c segment b segment a segment f segment g segment dp segment e segment d segment c segment b segment a segment f segment g segment dp segment e segment d segment c segment b segment a segment f segment g segment dp segment e step step step F/F code Data byte D Bit Blinking at step (=on) Blinking at step (=on) Blinking at step (=on) D segment d segment c segment b segment a segment f segment g step Blinking at step (=on) segment dp GREISINGER electronic GmbH Hans-Sachs-Straße D- Regenstauf Telefax ()

28 GIAN - Manual for connection and operation Version:. Page. Malfunction codes: FE: FE: FE: A corresponding fault code will be displayed as soon as the GIAN detects an operating state that is not permissible. Fault codes are defined as follows: FE: Measuring range has been exceeded This fault code indicates that the measuring range of the GIAN has been exceeded. Potential causes: Remedies: input signal too high sensor broken (KTY- and Pt) sensor short circuit (() to ma) counter overflow The fault code is reset as soon as the input signal has returned to within the permissible limits. Check sensor, measuring transducer and/or frequency generator. Reset counter. Values below measuring range This fault code indicates that the values of the A/D converter are below the measuring range. Potential causes: Remedies: input signal negative current below ma sensor short circuit (() to ma) sensor broken ( to ma) counter underflow The fault code is reset as soon as the input signal has returned to within the permissible limits. Check sensor, measuring transducer and/or frequency generator. Reset counter. Display range has been exceeded This fault code indicates that the permissible display range of the GIAN has been exceeded. Potential causes: please refer to FE Remedies: Values below display range please refer to FE This fault signal indicates that the values are below the permissible display range of the GIAN. Potential causes: please refer to FE Remedies: please refer to FE GREISINGER electronic GmbH Hans-Sachs-Straße D- Regenstauf Telefax ()

29 GIAN - Manual for connection and operation Version:. Page FE: FE: FE: Measuring signal interfered This signal indicates that the measuring signal at the input of the GIAN is unstable. Potential causes: Remedies: strong EMC interferences defective measuring transducer The fault message will disappear as soon as the measuring values detected by the GIAN are stable again. Check wiring, sensor and/or measuring transducer. Use screened cables if operating in an environment with strong interferences. System fault The GIAN is equipped with a self-diagnosis function for constantly checking essential parts of the GIAN. In case of a defect, the fault message FE is displayed. Potential causes: permissible operating temperature has been exceeded operating temperature below permissible range GIAN defective Remedies: Observe permissible operating temperature Exchange defective GIAN. Frequency measuring not possible Potential causes: continuos data transfer at RS interface Remedies: increase interface idle time between transfer to s at lenst. GREISINGER electronic GmbH Hans-Sachs-Straße D- Regenstauf Telefax ()

30 GIAN - Manual for connection and operation Version:. Page. Specification Sensor inputs: Can be selected via buttons located under the removable front plate or via the standard RS interface. Standard signals: to ma; Ri=Ohm to ma; Ri=Ohm tov; Ri=kOhm to V; Ri=kOhm Resistance input: for temperature measuring (-wire).two characteristic sensor curves are implemented: KTY-: -... C, resolution:, C Pt: -... C, resolution: C Digital zero point offset can be carried out via buttons or interface. Please note: Any temperature sensor with measuring transducer (Pt, NiCr-Ni, etc.) can be connected via standard signal input Frequency input: Measured frequency: bis Hz Resolution: Level: Hz 'LOW' <. Volt 'HIGH' >. Volt Permissible voltage: to V Application: e.g. frequency measurements, flow, flow rate (current values), speed, velocity etc. Counter input: Up- and down-counter up to max. pulses. Display max.. Level: 'LOW' <. Volt 'HIGH' >. Volt Permissible voltage: bis V Switchable scaler (can be programmed from to ). Pulse frequency up to pulses/second, in connection with max. scaler value up to pulses/second. Cascade arrangement of several GIAN possible, thus allowing unlimited extension of counting range ( places per unit). Application: e.g. flow quantity (overall quantity counter), piece counter, pulse counter, sum counter etc. Data Display: for use as a data display (without measuring function). Two display modes are possible. Please note: the data display function can only be activated by RS interface! - Digital display mode ("no "): a numeric value (translate by the interface) ist displayed. - Digital display mode ("no "): all display elements can be accessed directly. Additinally every -segment display can be set to 'flashing'. Accuracy: < ±.% ± sigit Display: Red LED with digits, mm high Range of application: Standard signal inputs: - to digits. Recommended display range: max. digits. KTY-: -. to. C Pt: - to C Scale: (can be adjusted via buttons or interface) Standard signal inputs: Any decimal point can be selected. Display range freely adjustable by entering of start and end values. Resistance input: Two characteristic sensor curves with preset measuring range implemented. Zero point offset can be carried out after entering an offset value. Frequency: Any decimal point can be selected. Freely adjustable gradient by entering the highest possible frequency and the corre Counter input (counter): Any decimal point can be selected. Freely adjustable gradient by entering the number of pulses and the corresponding display value. Switchable scaler ( to ). GREISINGER electronic GmbH Hans-Sachs-Straße D- Regenstauf Telefax ()

31 GIAN - Manual for connection and operation Version:. Page Filter: Digital filter, can be selected via buttons or interface. = no interference rejection (approx. to measurements/second). = interference rejection filter active (approx.. seconds delay). = interference filter active (same as but fault code FE displayed in addition in case of continuous measuring interference) Switching outputs: individual transistor switching outputs (GND switching). Switching current: ma Switching voltage: V DC Response time: < sec. after display change Possible configurations: Display -level controller Common min./max. alarm -level controller with min./max. alarm -level controller Individual min./max. alarm generator Counter with preselector switch Alarm delay: Range from to minutes can be set. Limitation of set-point value: Automatic with regard to the display range set. Supervisory function: Broken sensor and sensor short-circuit Values above/below permissible range Self-diagnosis integrated Hardware-Watchdog. Segment test: Automatic whenever unit is switched on. Data storage: All values programmed will be stored for at least years even without current supply (EEPROM). Interface: Standard RS interface. Up to units can be connected in a network via this -wire interface (Units no. to can be directly addressed via front-side keys or via interface). Connection to interface RS: via interface converter GRS or via any commercial interface adaptor RS to RS. Please note: In case of counter input no interface required. Supply voltage: to V DC Current consumption: Max. ma at V DC (without interface!) Electromagnetic compatibility: In accordance with EN- and EN- for unrestricted use in housing and industrial areas. Additional error: <% Unit tested with Filter = Housing: Glass-fibre reinforced Noryl. Dimensions: x mm. Mounting depths: approx. mm Panel mounting: With stainless steel spring clip. Panel thickness from to approx. mm. Panel cutout:.. x. mm (h x w) Electric connection: Standard connection by means of screw-type/plug-in terminals: -pin for interface and -pin for all remaining connections. Wire dia from. to. mm. IP-rating: IP with optional O-rings for front side IP upon request. Special accessories: GNR : Power pack with switching relay GRS : interface converter GSOFT: Software package for PC ( channel) GSOFTM: Software package for PC ( channels) GREISINGER electronic GmbH Hans-Sachs-Straße D- Regenstauf Telefax ()

GIR 230 TC Version 1.1

GIR 230 TC Version 1.1 E33.0.12.6C-02 Manual for connection and operation of the GIR 230 TC Page 1 of 14 Manual for connection and operation of GIR 230 TC Version 1.1 E33.0.12.6C-02 Manual for connection and operation of the

More information

GIR 230 FR Version 1.1

GIR 230 FR Version 1.1 E33.0.02.6C-02 Manual for connection and operation of GIR 230 FR page 1 of 20 Manual for connection and operation of GIR 230 FR Version 1.1 E33.0.02.6C-02 Manual for connection and operation of GIR 230

More information

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26 H20.0.34.6C-05 EASYBus-Sensor module for temperature from version V3.2 Operating Manual EBT 2R Content 1 INTENDED USE 2 2 GENERAL ADVICE 2 3 SAFETY INSTRUCTIONS 2 4 DISPOSAL NOTES 2 5 ASSIGNMENT 3 6 DIMENSION

More information

GIA 20 EB / PK as of version 2.5

GIA 20 EB / PK as of version 2.5 E31.0.21.6C-01 Manual for connection and operation of the GIA 20 EB / PK page 1 of 20 Manual for connection and operation of GIA 20 EB / PK as of version 2. GREISINGER electronic GmbH D - 3128 Regenstauf,

More information

GREISINGER electronic GmbH. D Regenstauf, Hans-Sachs-Straße 26. T-Logg 120 W -... T-Logg 120 K -...

GREISINGER electronic GmbH. D Regenstauf, Hans-Sachs-Straße 26. T-Logg 120 W -... T-Logg 120 K -... E39.0.1X.6C-01 Data logger for standard signals as of version 1.0 Operating Instruction T-Logg 120... T-Logg 120 W -... T-Logg 120 K -... GREISINGER electronic GmbH D - 93128 Regenstauf, Hans-Sachs-Straße

More information

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26 H20.0.24.6C1-07 EASYBus-Sensor module for humidity temperature with option: selectable humidity display from version V3.2 Operating Manual EBHT 2R / UNI Content 1 INTENDED USE 2 2 GENERAL ADVICE 2 3 SAFETY

More information

GREISINGER electronic GmbH. D Regenstauf, Hans-Sachs-Straße 26. T-Logg 100. T-Logg 100 E

GREISINGER electronic GmbH. D Regenstauf, Hans-Sachs-Straße 26. T-Logg 100. T-Logg 100 E E39.0.0X.6C-03 Data logger for temperature as of version V1.3 Operating Manual T-Logg 100 T-Logg 100 T-Logg 100 E GREISINGER electronic GmbH D - 93128 Regenstauf, Hans-Sachs-Straße 26 +49 (0) 9402 / 9383-0

More information

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26 E39.0.31.6C-02 Data logger for humidity temperature as of version V1.0 Operating Manual T-Logg 160 GREISINGER electronic GmbH D - 93128 Regenstauf, Hans-Sachs-Straße 26 +49 (0) 9402 / 9383-0 +49 (0) 9402

More information

DS 96/48 PK. Digital indicator. Manual 42/33-90 EN Rev. 00 DIM

DS 96/48 PK. Digital indicator. Manual 42/33-90 EN Rev. 00 DIM DS 96/48 PK Digital indicator Manual 42/33-90 EN Rev. 00 A1 A2 DIM E DS 96/48 PK Digital Indicator Manual Document No. 42/33-90 EN Edition 06.01 Revision 00 Manufacturer: ABB Automation Products GmbH Höseler

More information

Controller. Applications. Characteristics. Extruder machines Heating control systems Facility engineering Wide range of instrumentation

Controller. Applications. Characteristics. Extruder machines Heating control systems Facility engineering Wide range of instrumentation GHM GROUP CORPORATE GHM Messtechnik GmbH Schloßstr. 6 88453 Erolzheim GERMANY Phone +49 7354 937233-76 Fax +49 7354 937233-88 Controller Characteristics System Output Case 2-point-controller, 3-point-controller,

More information

Operating Manual Digital Quick Response Thermometer GMH 3210 For Thermocouple Probes Type J, K, N, S, T from Version 1.0

Operating Manual Digital Quick Response Thermometer GMH 3210 For Thermocouple Probes Type J, K, N, S, T from Version 1.0 H54.0.01.6C-02 Operating Manual Digital Quick Response Thermometer GMH 3210 For Thermocouple Probes Type J, K, N, S, T from Version 1.0 1 IN GENERAL... 1 1.1 SAFETY INSTRUCTIONS... 1 1.2 HOW TO OPERATE

More information

Operating instructions. Standstill monitor A / / 2011

Operating instructions. Standstill monitor A / / 2011 Operating instructions Standstill monitor A300 UK 1 2 3 4 5 6 7 8 7390337 / 01 02 / 2011 1 2 3 4 5 6 7 8 switchpoint min max pulse/min power Made in Germany ifm electronic gmbh D 45127 Essen func. I II

More information

USER MANUAL VIBRATION CONTROL RMA-POWER-BOX 107/230

USER MANUAL VIBRATION CONTROL RMA-POWER-BOX 107/230 USER MANUAL VIBRATION CONTROL Version 2.2 1 IMPORTANT NOTES Electrical danger within the meaning of this documentation or the warning labels on the product itself respectively means that death, serious

More information

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH Industriefunkuhren Technical Manual Signal Converter for DIN Rail Mounting Series 4800xx-yy ENGLISH Version: 01.01-19.07.2007 2 / 23 Signal Converter 4800 - V01.01 INPORTANT NOTES Downloading Technical

More information

signo 727 SSI operating instructions

signo 727 SSI operating instructions operating instructions signo 727 SSI Position-Indicator with/without limit values and SSI input from absolute encoder 1. Safety instructions This instrument has been built and tested in accordance with

More information

signo 727 SSI Operating Instructions Position-Indicator with/without limit values and SSI input from absolute encoder

signo 727 SSI Operating Instructions Position-Indicator with/without limit values and SSI input from absolute encoder Operating Instructions signo 727 SSI Position-Indicator with/without limit values and SSI input from absolute encoder Contents 1. Safety instructions 1 2. Mounting of the position indicator 2 2.1 Mounting

More information

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Rhino Buffer Module PSM24-BFM600S. Operating Instructions Rhino Buffer Module PSM24-BFM600S Operating Instructions RHINO BUFFER MODULE PSM24-BFM600S Description The PSM24-BFM600S Buffer Module will hold the output voltage of a 24 VDC power supply after brownouts

More information

531K. Process Display Temperature display for Pt100 and Ni100 RTD's. Installation and Operating Manual

531K. Process Display Temperature display for Pt100 and Ni100 RTD's. Installation and Operating Manual 531K Process Display Temperature display for Pt100 and Ni100 RTD's Installation and Operating Manual 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com

More information

LCI User Manual mantracourt.com

LCI User Manual mantracourt.com LCI User Manual mantracourt.com LCI Load Cell Junction Box with Fault Monitor Contents Chapter 1 Introduction to the LCI... 2 Chapter 2 Installing the LCI... 3 Chapter 3 Setting up the LCI... 4 Sequence

More information

Electronic Temperature Controller. Instruction Manual Version

Electronic Temperature Controller. Instruction Manual Version Electronic Temperature Controller 701 Instruction Manual Version 1.00.01 Dear Customer, we have made up this operating manual in such a way that all necessary information about the product can be found

More information

Digital Quick-Response Thermometer

Digital Quick-Response Thermometer H56.0.01.6C-06 Digital Quick-Response Thermometer Operating Manual GTH 1170 WEEE-Reg.-Nr. DE93889386 GHM Messtechnik GmbH Standort Greisinger Hans-Sachs-Str. 26 D-93128 Regenstauf +49 (0) 9402 / 9383-0

More information

Non-communicating room controllers

Non-communicating room controllers 3 882 DESIGO RXA Non-communicating room controllers RXA29.1 For fan-coil systems The RXA29.1 room controller are used for temperature control in individual rooms. For 2-pipe or 4-pipe fan-coil systems,

More information

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26 phone: / , fax: / ,

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26 phone: / , fax: / , H55.0.21.6C-02 Operating Manual Precision Barometer from Version 1.0 GPB 3300 GREISINGER electronic GmbH D - 93128 Regenstauf, Hans-Sachs-Straße 26 phone: +49 9402 / 9383-0, fax: +49 9402 / 9383-33, email:

More information

GMH Operating Manual for Digital Quick-Response Thermometer

GMH Operating Manual for Digital Quick-Response Thermometer H58.0.01.6C-02 Operating Manual for Digital Quick-Response Thermometer GMH 1170 WEEE-Reg.-Nr. DE93889386 GHM Messtechnik GmbH Standort Greisinger Hans-Sachs-Str. 26 D-93128 Regenstauf +49 (0) 9402 / 9383-0

More information

LCI Load Cell Junction Box with Fault Monitor

LCI Load Cell Junction Box with Fault Monitor LCI Load Cell Junction Box with Fault Monitor User Manual www.mantracourt.co.uk The LCI Load Cell Failure Alarm Manual Chapter 1 Introduction to the LCI...2 Chapter 2 Installing the LCI...3 Figure 2.1

More information

INSTRUCTION MANUAL TRIP CIRCUIT SUPERVISION RELAY GKAD1

INSTRUCTION MANUAL TRIP CIRCUIT SUPERVISION RELAY GKAD1 INSTRUCTION MANUAL TRIP CIRCUIT SUPERVISION RELAY GKAD1 TOSHIBA Corporation 2004 All Rights Reserved. ( Ver. 1.6 ) Safety Precautions Before using this product, please read this chapter carefully. This

More information

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend Solid State Relays with Failure Detection Function G3PC Refer to Warranty and Application Considerations (page 1), Safety Precautions (page 4), and Technical and Safety Information (page 6). Detects failures

More information

IV-30 Operating Manual for Pulse Distributor Cassette with potential separation

IV-30 Operating Manual for Pulse Distributor Cassette with potential separation IV-30 Operating Manual for Pulse Distributor Cassette with potential separation Edition-/Rev.-Date: 09/08/2006 Document-/Rev.-No.: TR - EAK - BA - GB - 0093-02 Software version: - File name: TR-EAK-BA-GB-0093-02.DOC

More information

Model Number Structure

Model Number Structure Solid State Relays with Failure Detection Function G3PC CSM_G3PC_DS_E_1_1 Refer to Safety Precautions for All Solid State Relays. Detects failures in SSR used for heater temperature control and simultaneously

More information

Operation Manual Profibus DP -Display HE 5120 P with digital I/O's

Operation Manual Profibus DP -Display HE 5120 P with digital I/O's Operation Manual Profibus DP -Display HE 510 P with digital I/O's "HESCH" Schröder GmbH Boschstraße 8 31535 Neustadt Telefon +49 (0) 503 / 9535-0 Telefax +49 (0) 503 / 9535-99 e-mail: info@hesch.de http://www.hesch.de

More information

2-Axis Counter BDD 622

2-Axis Counter BDD 622 2-Axis Counter BDD 622 Technical Description, User's Guide english No. 622-221 D/E. Edition 0701; Subject to modification. www.balluff.com Balluff GmbH Schurwaldstrasse 9 73765 Neuhausen a.d.f. Germany

More information

VersaPoint I/O Module

VersaPoint I/O Module Output 24VDC Positive Logic 0.5A 14 Points Module is used to output 24VDC digital signals. Module Specifications Housing dimensions (width x height x depth) Connection style Operating temperature 48.8mm

More information

Model Number Structure

Model Number Structure Solid State Relays with Failure Detection Function G3PC Detects failures in SSR used for heater temperature control and simultaneously outputs alarm signal. This SSR supports the safe design of heater

More information

Control unit SG-EFS 104/2W. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/2W 24 V=/~

Control unit SG-EFS 104/2W. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/2W 24 V=/~ Innovative by tradition. Control unit SG-EFS 104/2W EN Operating instructions Version 0.9 1005196 SG-EFS 104/2W 24 V=/~ Original instructions Mayser GmbH & Co. KG Örlinger Straße 1 3 89073 Ulm GERMANY

More information

User manual BLCDN-8M12LT-8XSG-PD-8XSGPD

User manual BLCDN-8M12LT-8XSG-PD-8XSGPD User manual BLCDN-8M12LT-8XSG-PD-8XSGPD Edition: 2011-3-15 All brand and product names are trademarks or registered trade marks of the owner concerned. Hans Turck GmbH, Mülheim an der Ruhr All rights reserved,

More information

Universal interface adapter for GMSD / GMxD - sensor

Universal interface adapter for GMSD / GMxD - sensor S56.0.01.6C-09 Universal interface adapter for GMSD / GMxD - sensor Installation and operating manual GDUSB 1000 WEEE-Reg.-Nr. DE93889386 GHM Messtechnik GmbH Standort Greisinger Hans-Sachs-Str. 26 D-93128

More information

PFC-10 Power Factor Controller

PFC-10 Power Factor Controller PFC-10 Power Factor Controller Instruction Manual Ver. 6.0 / 2002 (2-2005 update) Table of Contents Page Subject 3 Starter ion 4-5 Installation Notes 6-7 Terminals Review & Control Wiring 8 Front-panel

More information

SCHMIDT Sensor interface PROFIBUS Instructions for use

SCHMIDT Sensor interface PROFIBUS Instructions for use SCHMIDT Sensor interface PROFIBUS Instructions for use Table of contents 1 Important information... 3 2 Intended use... 4 3 Electrical connection... 4 4 Signalizations... 7 5 Startup... 9 6 Technical data...

More information

Operating instructions. Speed monitor D / / 2014

Operating instructions. Speed monitor D / / 2014 Operating instructions Speed monitor D200 80005257 / 00 05 / 2014 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5 2.2 Target group...5

More information

Electronic SD1, AS 8, ASR 14, ASR 20

Electronic SD1, AS 8, ASR 14, ASR 20 Electronic SD1, AS 8, ASR 14, ASR 20 2 Electronic SD1, AS 8, ASR 14, ASR 20 Contents Page List of contents..................................................... 3 Function and characteristics.........................

More information

Operating Instructions PRO-AB /6.15. Leakage Current Measuring Adapter

Operating Instructions PRO-AB /6.15. Leakage Current Measuring Adapter Operating Instructions PRO-AB Leakage Current Measuring Adapter 3-349-621-15 3/6.15 Table of Contents Page 1 Scope of delivery...2 2 Safety Precautions...2 3 General...3 4 Preparing for Measurement...4

More information

Digital Indicator Solutions

Digital Indicator Solutions Digital Indicator Solutions Loop-Powered Attachable Compact Attachable Loop-Powered Smart Compact System Loop-Powered Compact Smart System Intelligent Smart System "Intelligent" Options Dual & Display

More information

Compact universal controllers

Compact universal controllers 7 867 Compact universal controllers RWF55... The RWF55 is used mainly for controlling the temperature or pressure in oil- or gas-fired heating plants. If the relevant parameters are set, the RWF55 can

More information

Device manual Profibus encoder. RM30xx RN30xx /00 06/2013

Device manual Profibus encoder. RM30xx RN30xx /00 06/2013 Device manual Profibus encoder RM30xx RN30xx 706355/00 06/2013 Contents 1 Preliminary note................................................. 4 1.1 Symbols used...............................................

More information

PRODIS -SSI Digital Process Meter for SSI position sensors. Instruction Manual. Please read carefully before installation and operation!

PRODIS -SSI Digital Process Meter for SSI position sensors. Instruction Manual. Please read carefully before installation and operation! Digital Process Meter for SSI position sensors Please read carefully before installation and operation! Contents Contents Specifications 2 Safety instructions 3 Description 4 Mechanical mounting 4 Operation

More information

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO Order Number: 8160.UISO Status: V3; 17.09.2010c G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany 1 TABLE OF CONTENTS PLEASE READ BEFORE USE... 3 DESCRIPTION... 5 UMB ISO CONVERTER ISOCON... 6 CONFIGURATION...

More information

Operating Instructions Differential Pressure Transducer PS27

Operating Instructions Differential Pressure Transducer PS27 Operating Instructions Differential Pressure Transducer PS27 halstrup-walcher GmbH Stegener Straße 10 79199 Kirchzarten/Germany Phone: +49 (0) 76 61/39 63 0 Fax: +49 (0) 76 61/39 63 99 E-mail: info@halstrup-walcher.com

More information

VersaMax IP I/O Module

VersaMax IP I/O Module Module accepts four digital input signals and provides four digital outputs. It connects to a local bus that is interfaced to a Profibus-DP / PROFINET network by a Profibus Interface Unit (IC677PBI001)

More information

Installation & Operation

Installation & Operation LED Readout Installation & Operation WARRANTY Accurate Technology, Inc. warrants the ProScale Systems against defective parts and workmanship for 1 year commencing from the date of original purchase. Upon

More information

Single-Axis Counter BDD 611

Single-Axis Counter BDD 611 Single-Axis Counter BDD 611 Technical Description, User's Guide english No. 611-150 D/E. Edition 0705; Subject to modification. Replaces edition 0701. www.balluff.com Balluff GmbH Schurwaldstrasse 9 73765

More information

PSR-PC50. SIL 3 coupling relay for safety-related switch on. Data sheet. 1 Description

PSR-PC50. SIL 3 coupling relay for safety-related switch on. Data sheet. 1 Description SIL 3 coupling relay for safety-related switch on Data sheet 105818_en_01 PHOENIX CONTACT 2014-08-18 1 Description The PSR-PC50 SIL coupling relay can be used for power adaptation and electrical isolation

More information

HGM9580 Bus Tie Bus Parallel Unit USER MANUAL. Smartgen Technology

HGM9580 Bus Tie Bus Parallel Unit USER MANUAL. Smartgen Technology HGM9580 Bus Tie Bus Parallel Unit USER MANUAL Smartgen Technology This manual is suitable for HGM9580 bus tie bus parallel unit only. Clarification of notation used within this publication. SIGN INSTRUCTION

More information

SATEL I-LINK 100 MB I/O-converter User Guide, Version 1.1

SATEL I-LINK 100 MB I/O-converter User Guide, Version 1.1 TABLE OF CONTENTS TABLE OF CONTENTS... 1 IMPORTANT NOTICE... 2 PRODUCT CONFORMITY... 3 WARRANTY AND SAFETY INSTRUCTIONS... 4 1 GENERAL... 5 1.1 SATEL I-LINK 100 MODBUS I/O- CONVERTER... 5 2 SPECIFICATIONS...

More information

Operating manual. GTL - Configuration tool. Please keep the manual for future use.

Operating manual. GTL - Configuration tool. Please keep the manual for future use. Operating manual GTL - Configuration tool Please keep the manual for future use. V1.00-01 GREISINGER Electronic GmbH Hans-Sachs-Str. 26 93128 Regenstauf Germany Fon +49(0)9402-9383-0 Fax +49(0)9402-9383-33

More information

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

Rhino Redundancy Module PSM24-REM360S. Operating Instructions Rhino Redundancy Module PSM4-REM360S Operating Instructions RHINO REDUNDANCY MODULE PSM4-REM360S Description With this module and two power supplies of the PSM series (78, 90, 56, 80 and 360 watt models),

More information

NMID. Remote control. SAPIM I/O number. SAPIM I/O number NBRN (RS485) ZM100. Relay, 24 VDC - + UO07 UI11 UI10 UI09 UI08 UI07 UI06 UI05 UI04 UI03 UI02

NMID. Remote control. SAPIM I/O number. SAPIM I/O number NBRN (RS485) ZM100. Relay, 24 VDC - + UO07 UI11 UI10 UI09 UI08 UI07 UI06 UI05 UI04 UI03 UI02 1/8 NRK16/A, NRK16-B/A, (NRK16-T /A, NRK14-T /A, NRK16-WEB/A) Control and interlock devices with pre-programmed system-specific application modules The controllers may be used as stand-alone control and

More information

BNI IOL A027 BNI IOL A027

BNI IOL A027 BNI IOL A027 BNI IOL-771-000-A027 BNI IOL-772-000-A027 IO-Link Version 1.1 Universel IO-Link Interface With undervoltage / broken coil detection User s Guide Inhalt 1 Notes to the user 2 1.1. About this guide 2 1.2.

More information

Intrinsically safe batch controller Batching Master 110i

Intrinsically safe batch controller Batching Master 110i Intrinsically safe batch controller Batching Master 110i Installation Guide BVS 04 AT E 172 Revision 12.2 IBS BatchControl GmbH Im Sträßchen 2-4 Tel.: ++49 2441 9199 801 53925 Kall Fax.: ++49 2441 9199

More information

TB 45 Temperature limiter / monitor

TB 45 Temperature limiter / monitor TB 45 Temperature limiter / monitor Compact design Suitable for heating and refrigeration processes For all thermocouple types and resistive sensors Display & operating functions Communication functions

More information

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26 phone: / , fax: / ,

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26 phone: / , fax: / , H55.0.31.6C-04 Operating Manual Vacuum- / Baro- / Manometer from Version 1.1 GDH 200-14 GREISINGER electronic GmbH D - 93128 Regenstauf, Hans-Sachs-Straße 26 phone: +49 9402 / 9383-0, fax: +49 9402 / 9383-33,

More information

Fast Safe Secure USER MANUAL. Sentinel Z18 Flap Barrier. For more Information: t: e:

Fast Safe Secure USER MANUAL. Sentinel Z18 Flap Barrier. For more Information: t: e: Fast Safe Secure USER MANUAL Sentinel Z18 Flap Barrier For more Information: t: +61 07 3205 1123 e: info@rotech.com.au www.rotech.com.au 6 Table of Contents Summary... 1. Technical Parameter... 2. Function

More information

The Indicator with 3 Limit Contacts

The Indicator with 3 Limit Contacts A 1200 The Indicator with 3 Limit Contacts Format: Installation depth: 96x48 mm (1/8-DIN) 122 mm Description and Operating Manual ELOTECH Industrieelektronik GmbH Verbindungsstrasse 27 D 40723 HILDEN FON

More information

SIMATIC. ET 200S distributed I/O 2AO U ST analog electronic module (6ES7135-4FB01-0AB0) Preface. Properties 1. Parameters 2.

SIMATIC. ET 200S distributed I/O 2AO U ST analog electronic module (6ES7135-4FB01-0AB0) Preface. Properties 1. Parameters 2. SIMATIC ET 200S distributed I/O SIMATIC ET 200S distributed I/O 2AO U ST analog electronic module (6ES7135-4FB01-0AB0) Manual Preface Properties 1 Parameters 2 Diagnostics 3 Analog value representation

More information

UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS EN0I-6041 12/99 PRODUCT SPECIFICATION SHEET OVERVIEW The UDC 1000 and UDC 1500 are microprocessor-based 1/16 DIN and 1/8 DIN controllers

More information

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications 3 834 DESIO RX Individual room controllers for fan-coil systems, chilled ceilings and radiators, with MARK-compatible bus communications RXC20.1 RXC21.1 The RXC20.1 and RXC21.1 controllers are used for

More information

Hygro-/Thermometer. Operating Manual GFTH 95

Hygro-/Thermometer. Operating Manual GFTH 95 H53.0.X1.6C-07 Hygro-/Thermometer Operating Manual GFTH 95 WEEE-Reg.-No. DE93889386 GHM Messtechnik GmbH Standort Greisinger Hans-Sachs-Str. 26 D-93128 Regenstauf +49 (0) 9402 / 9383-0 +49 (0) 9402 / 9383-33

More information

BNI PNT Z015 BNI PNT Z015 BNI PNT Z015 BNI PNT Z015 BNI PNT Z015. IP67 Modules User s Guide

BNI PNT Z015 BNI PNT Z015 BNI PNT Z015 BNI PNT Z015 BNI PNT Z015. IP67 Modules User s Guide BNI PNT-104-105-Z015 BNI PNT-202-105-Z015 BNI PNT-206-105-Z015 BNI PNT-302-105-Z015 BNI PNT-305-105-Z015 IP67 Modules User s Guide Content 1 Notes 3 1.1. About this guide 3 1.2. Structure of the guide

More information

Operating Instructions. For. Level Control Module. Model SSR 1000

Operating Instructions. For. Level Control Module. Model SSR 1000 Operating Instructions For Level Control Module Model SSR 1000 SSR Operation Instructions Rev. 1 Jan 01 Page 1/7 1. Note Please read and take note of these operating instructions before unpacking and commissioning.

More information

UNIVERSAL TRANSDUCER AR594

UNIVERSAL TRANSDUCER AR594 APAR - SALES OFFICE 05-090 Raszyn, ul. Gałczyńskiego 6, Poland Tel. +48 22 101-27-31, +48 22 853-49-30 E-mail: automatyka@apar.pl Website: www.apar.pl USER INSTRUCTION UNIVERSAL TRANSDUCER AR594 Version

More information

Cube67 - Modular I/O station

Cube67 - Modular I/O station Compact modules Cube67 DI16 C 8xM12 Cube67 DI8 C 4xM12 Cube67 DI8 C 8xM8 Digital inputs Art.-No. UL 56602 UL 56612 UL 56622 approx. 50 ma approx. ma Terminator integrated Configuration PIN 2 input/diagnostic

More information

PHOENIX CONTACT - 07/2006

PHOENIX CONTACT - 07/2006 Buffer module with maintenance-free capacitor-based power storage device INTERFACE Data sheet 102035_03_en PHOENIX CONTACT - 07/2006 Description Short-term mains interruptions are bridged by QUINT BUFFER,

More information

InBin-P Pressure switches from 5 Pa Pa

InBin-P Pressure switches from 5 Pa Pa InBin-P Pressure switches from 5 Pa...100 Pa Electrical, binary pressure or differential pressure switches with adjustable switch activation delay 24 VAC/DC supply voltage, potential free switching contact

More information

USER INSTRUCTION MANUAL FOR LOADCELL TRANSMITTER MODEL TDC/I/0550 (SOFTWARE: VER2A) INDEX

USER INSTRUCTION MANUAL FOR LOADCELL TRANSMITTER MODEL TDC/I/0550 (SOFTWARE: VER2A) INDEX USER INSTRUCTION MANUAL FOR LOADCELL TRANSMITTER MODEL TDC/I/0550 (SOFTWARE: VER2A) INDEX DOCUMENT NO: TDC 0550 MANUAL - 2 1.0) INTRODUCTION. PAGE 2 1.1) ABOUT THIS MANUAL. PAGE 2 1.2) INTRODUCTION. PAGE

More information

Transducers for Pt-100/1000, Resistors

Transducers for Pt-100/1000, Resistors Transducers for Pt-100/1000, Resistors Microprocessor-based technology General Description Isolating transducers with digital programming of ranges, for DIN-rails or for printed circuit boards. Modules

More information

SmartWire-DT Modules IP67

SmartWire-DT Modules IP67 Manual 05/15 MN120006EN SmartWire-DT Modules IP67 All proprietary names and product designations are brand names or trademarks registered to the relevant title holders. Break-Down Service Please call your

More information

Solid State Remote Power Controller E /627

Solid State Remote Power Controller E /627 Solid State Remote Power Controller E--623/62 Description The E-T-A Solid State Remote Power Controllers E--623/62 are electronic control modules suitable for inductive loads such as electromagnetic valves

More information

JUMO ecotrans ph 03 Microprocessor transmitter/ switching device for ph/redox voltage and temperature

JUMO ecotrans ph 03 Microprocessor transmitter/ switching device for ph/redox voltage and temperature Page 1/7 JUMO ecotrans 03 Microprocessor transmitter/ switching device for /Redox voltage and temperature with a 2-line LCD for mounting on a 35 mm DIN rail Brief description Depending on the configuration,

More information

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3 Operating Instructions Control Unit SG-EFS 1X4 ZK2/1 8k2 Version 3 1003100 SG-EFS 104 ZK2/1 8k2 24 V=/~ 7500354 SG-EFS 134 ZK2/1 8k2 230 V~ Original instructions GmbH & Co. KG Polymer Electric Örlinger

More information

Device manual Field modules DP AC2630 / AC2631 / AC2634 AC2636 / AC2637 / AC / / 2013

Device manual Field modules DP AC2630 / AC2631 / AC2634 AC2636 / AC2637 / AC / / 2013 Device manual Field modules DP AC2630 / AC2631 / AC2634 AC2636 / AC2637 / AC2638 7390983 / 00 03 / 2013 Contents 1 Preliminary note................................................. 4 2 Safety instructions...............................................

More information

Tachometers TC-4B-V TC-6A-V Electronic cam-operated switching devices FC-21-V... 50

Tachometers TC-4B-V TC-6A-V Electronic cam-operated switching devices FC-21-V... 50 List of content page Counters and indicators DA5-IU-C... 10 DA5-IU-2K-C... 12 DA5-IU-2K-V... 12 KCM-51-C... 14 KCM-51-V... 14 KCM-70-C... 16 KCM-70-V... 16 KCM-70A-C... 18 KCM-70A-V... 18 KCT-6S-C... 20

More information

ecomat 100 type R 360 Use as safety controller

ecomat 100 type R 360 Use as safety controller Supplement to the system manual ecomat 100 type R 360 Use as safety controller Supplement to the system manual ecomat 100 type R 360, April 2000 Warranty This manual was written with the utmost care. However,

More information

Set-up and programming guide

Set-up and programming guide Set-up and programming guide HV 2.015-4.220 software for compatibility to HV 2.1-3.22 V 2012/05A-C01.4 771079512 Manual C01.4 for HV 2.015-4.220 ENGLISH Index 1 Important safety instructions...2 2 General

More information

Expansion Module HZS 541-1S

Expansion Module HZS 541-1S Expansion Module HZS 541-1S 12.10.2015 Page 1 System Description The external HZS 541-1S expansion module provides users of biomass heating systems with additional 230 V AC relay outputs, analog inputs

More information

Operating Instructions for Digital Thermometers. Model: DTM

Operating Instructions for Digital Thermometers. Model: DTM Operating Instructions for Digital Thermometers Model: 1. Contents 1. Contents... 2 2. Note... 3 3. Instrument Inspection... 3 4. Regulation Use... 3 5. Operating Principle... 4 6. Mechanical Connection...

More information

VariTrans P Standard-Signal Isolators

VariTrans P Standard-Signal Isolators VariTrans Standard-Signal Isolators Warranty Defects occurring within 5 years from delivery date shall be remedied free of charge at our works (carriage and insurance paid by sender). The professional

More information

Thread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm

Thread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm Long Distance Cylindrical. Extra long for increased protection and sensing performance triple proximity sensors for flush mounting requirements. designed and tested for extra long life. Ordering Information

More information

english S-5EC Potentiometer 5-step Operating Instructions Keep for reference! L-BAL-E265-GB 1608 Index 002

english S-5EC Potentiometer 5-step Operating Instructions Keep for reference! L-BAL-E265-GB 1608 Index 002 S-5EC english Potentiometer 5-step Operating Instructions Keep for reference! Content 1 General notes............................................ 3 1.1 Structure of the operating instructions....................

More information

INSTRUCTION MANUAL WCS-Interface Module, DeviceNet

INSTRUCTION MANUAL WCS-Interface Module, DeviceNet FACTORY AUTOMATION INSTRUCTION MANUAL WCS-Interface Module, DeviceNet WCS-DG210 Part. No. 202340 / DOCT-1305 / 11. june 2007 1 Working principle............................ 6 2 Installation and commissioning.................

More information

GFK-2415A March Type of sensor connection

GFK-2415A March Type of sensor connection VersaMax IP Expansion Module has four analog differential inputs that can be configured as current or voltage inputs. It connects to a local bus that is interfaced to a Profibus-DP / PROFINET network by

More information

Operating Instructions VEGAMET 381

Operating Instructions VEGAMET 381 Operating Instructions VEGAMET 381 in out Contents Contents 1 About this document... 4 1.1 Function... 4 1.2 Target group... 4 1.3 Symbolism used... 4 2 For your safety... 6 2.1 Authorised personnel...

More information

SD1. Differential Controller. Operating and Installation Instructions F2 72.3

SD1. Differential Controller. Operating and Installation Instructions F2 72.3 SD1 Differential Controller Operating and Installation Instructions F2 72.3 i Please follow the safety information and read these Instructions carefully before putting the system into operation. Safety

More information

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation: DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER The DKM-409 is a precision instrument designed for displaying various AC parameters in 3-phase distribution panels. Thanks to its isolated

More information

BNI IOL Z012. User s Guide

BNI IOL Z012. User s Guide BNI IOL-719-002-Z012 User s Guide Content 1 Notes for the user 3 1.1. Structure of the guide 3 1.2. Typographical Conventions 3 Enumerations 3 Actions 3 Syntax 3 Cross references 3 1.3. Symbols 3 1.4.

More information

DINALOG A 144 x 36 A1400 Light-Strip Indicator

DINALOG A 144 x 36 A1400 Light-Strip Indicator DINALOG A x 6 A00 Light-Strip Indicator -9-0-0 /.00 Front panel dimensions: x 6 mm Light-strip indicator with 7 high-contrast LEDs Red LED display color Digital display range for portrait format: 999 to

More information

Signal conditioning instruments for level switches. Conductive VEGATOR 256C VEGATOR 532 VEGATOR 631. Product Information

Signal conditioning instruments for level switches. Conductive VEGATOR 256C VEGATOR 532 VEGATOR 631. Product Information Signal conditioning instruments for level switches Conductive VEGATOR C VEGATOR VEGATOR Product Information Content Content Product description..........................................................................

More information

The PM1000 series is a universal 4 digit LED plug-on display for transmitters with 4-20mA 2 wire output and fitted with DIN43650 connector.

The PM1000 series is a universal 4 digit LED plug-on display for transmitters with 4-20mA 2 wire output and fitted with DIN43650 connector. PM1000 SERIES PLUG-ON DISPLAY BRIGHT LED DISPLAY INDICATION RANGE -999 TO +9999 FITS TO DIN 43650 CONNECTOR PLUG-ON TO ANY TRANSMITTER WITH 4-20MA OUTPUT EASY TO SCALE ON SITE ROBUST DESIGN SET POINT OPTION

More information

MSR Level Control Relay Module Operating Instructions for Level Control Relay Module Model: MSR

MSR Level Control Relay Module Operating Instructions for Level Control Relay Module Model: MSR Operating Instructions for Level Control Relay Module Model: MSR MSR Operation Instructions Rev. Apr 07 Page 1/8 1. Note Please read and take note of these operating instructions before unpacking and commissioning.

More information

Operating Instructions

Operating Instructions Innovative by tradition. Operating Instructions Control Unit SG-RSV 239 Version 1 1003986 SG-RSV 239/24 24 V= 1005372 SG-RSV 239/36 36 V= 1003271 SG-RSV 239 50-150 V= Mayser GmbH & Co. KG Örlinger Straße

More information

Alarm Unit DG 3200 Control And Monitor Standard Signals

Alarm Unit DG 3200 Control And Monitor Standard Signals Alarm Unit DG 3200 Control And Monitor Standard Signals With the Alarm Unit DG 3200 DRAGO is extending its offer on high-functional and high-reliable components of the interface technique. The Alarm Unit

More information

Instruction Manual. Instrument Amplifier HE 017

Instruction Manual. Instrument Amplifier HE 017 Instruction Manual Instrument Amplifier HE 017 List of contents INSTRUCTION MANUAL: HE 017 Date: 20.4.99 Art.-No.: 320999 S General Safety Instructions.......................................... S 1 General

More information