SmartVFD Frame 8 Wiring Diagrams and Dimensional Drawings
|
|
- Darrell Leonard
- 6 years ago
- Views:
Transcription
1 Smart Frame 8 Wiring Diagrams and Dimensional Drawings Smart Frame Size Vac: HP 08/0 Vac: HP SPECIFICATION DATA CONTENTS Smart Frame 8 Wiring Diagrams... Frame 8, Fused Disconnect Wiring Diagram... Frame 8, Contactor Wiring Diagram... Frame 8, Contactor Wiring Diagram... 4 Frame 8, Contactor Auto-bypass Wiring Diagram... 5 Smart Frame 8 Dimensional Diagrams... 6 Frame 8 NEMA : Disconnect Only and Contactor Dimensional Drawing... 6 Frame 8 NEMA: Contactor & Contactor with Auto-Bypass Dimensional Drawing... 7 Frame 8: NEMAR, Disconnect only, Contactor, Contactor and Contactor with Auto-Bypass Drawing... 8 Put Bar Code Here
2 SMART FRAME 8 WIRING DIAGRAMS AND DIMENSIONAL DRAWINGS A B VREF: REFERANCE OUTPUT AI+: AI, OR /AI-: AI COMMON AI+: AI, OR /AI-: AI COMMON 4V OUT: 4V AUXILLARY : I/O GROUND DIN: DIGITAL INPUT DIN: DIGITAL INPUT DIN: DIGITAL INPUT CM: COMMON FOR DI - DI 4V OUT: 4V AUXILLARY : I/O GROUND DIN4: DIGITAL INPUT 4 DIN5: DIGITAL INPUT 5 DIN6: DIGITAL INPUT 6 CM: COMMON FOR DI4 - DI6 AO+: ANALOG SIGNAL +OUT AO-/: ANALOG OUTPUT COMMON +4VIN: 4V AUXILLARY INPUT RS485: NEGATIVE RS485: POSITIVE RO/ N.C. RO/ CM RO/ N.O. RO/ N.C. RO/ CM RO/ N.O. RO/ CM RO/ N.O. RELAY OUTPUT RELAY OUTPUT RELAY OUTPUT W V U SMART U V W ALL PANELS SHIPPED WITH DEFAULT PROGRAMMING PARAMETERS. SET DIP SWITCHES AS NEEDED. TS, FAN STANDARD ON ALL NEMA R PANELS. FAN ON 0HP, 40HP, AND 00HP AT 480V. HEATER IS OPTIONAL ON ALL NEMA R PANELS. TRANSFORMER ONLY REQUIRED ON R MODELS. DISCONNECT PANEL HAS FUSED MAIN DISCONNECT. DRIVE ONLY PANEL HAS WIRE TERMINALS. ON DRIVE ONLY PANEL, CUSTOMER IS RESPONSIBLE FOR BRANCH CIRCUIT AND SHORT CIRCUIT PROTECTION. ALL WIRING: USE COPPER WIRE ONLY SUITABLE FOR MIN. 75 DEG. C, FIELD WIRING, NEC CLASS. MOTOR AND FEEDER WIRE SIZE MUST BE IN ACCORDANCE WITH NEC. FIELD WIRE WIRE INSIDE C/PNL OPTION DIP SWITCHES ON RS485 A0 AI AI LOCATED BEHIND COVER, RIGHT SIDE OF KEYPAD M46 Fig.. Frame 8, Fused Disconnect Wiring Diagram
3 SMART FRAME 8 WIRING DIAGRAMS AND DIMENSIONAL DRAWINGS A B VREF: REFERANCE OUTPUT AI+: AI, OR /AI-: AI COMMON AI+: AI, OR /AI-: AI COMMON 4V OUT: 4V AUXILLARY : I/O GROUND DIN: DIGITAL INPUT DIN: DIGITAL INPUT DIN: DIGITAL INPUT CM: COMMON FOR DI - DI 4V OUT: 4V AUXILLARY : I/O GROUND DIN4: DIGITAL INPUT 4 DIN5: DIGITAL INPUT 5 DIN6: DIGITAL INPUT 6 CM: COMMON FOR DI4 - DI6 AO+: ANALOG SIGNAL +OUT AO-/: ANALOG OUTPUT COMMON +4VIN: 4V AUXILLARY INPUT RS485: NEGATIVE RS485: POSITIVE RO/ N.C. RO/ CM RO/ N.O. RO/ N.C. RO/ CM RO/ N.O. RO/ CM RO/ N.O. RELAY OUTPUT RELAY OUTPUT RELAY OUTPUT W V U SMART U V W ALL PANELS SHIPPED WITH DEFAULT PROGRAMMING PARAMETERS. SET DIP SWITCHES AS NEEDED. IF CUSTOMER SAFETY INTERLOCK IS USED, REMOVE J. TS, FAN STANDARD ON ALL NEMA R PANELS. FAN ON 5HP AND LARGER AT 480V. HEATER IS OPTIONAL ON ALL NEMA R PANELS. ALL WIRING: USE COPPER WIRE ONLY SUITABLE FOR MIN. 75 DEG. C, FIELD WIRING, NEC CLASS. MOTOR AND FEEDER WIRE SIZE MUST BE IN ACCORDANCE WITH NEC. FIELD WIRE WIRE INSIDE C/PNL OPTION DIP SWITCHES ON RS485 A0 AI AI LOCATED BEHIND COVER, RIGHT SIDE OF KEYPAD M45 Fig.. Frame 8, Contactor Wiring Diagram
4 SMART FRAME 8 WIRING DIAGRAMS AND DIMENSIONAL DRAWINGS L L /.4 /.4 SHIELD ALL WIRING: USE COPPER WIRE ONLY SUITABLE FOR MIN. 75 DEG. C, FIELD WIRING, NEC CLASS. MOTOR AND FEEDER WIRE SIZE MUST BE IN ACCORDANCE WITH NEC. FIELD WIRE WIRE INSIDE C/PNL OPTION LOCATED BEHIND COVER, RIGHT SIDE OF KEYPAD. AI 0-0 VDC OR 4-0 ma SHD AT FIELD END USE CONDUCTOR SHD, TWISTED PAIR WIRE AI 0-0 VDC OR 4-0 ma SPEED REFERENCE NOTE : ALL PANELS SHIPPED WITH DEFAULT PROGRAMMING PARAMETERS. SET DIP SWITCHES AS NEEDED, SEE DETAIL B NOTE : IF CUSTOMER SAFETY INTERLOCK IS USED, REMOVE J. NOTE : TS, FAN STD ON ALL NEMR PNLS. FAN, ON 5HP & 480V. HEATER IS OPTIONAL ON ALL NEMA R PNLS. AI AI TEST AO START COMMAND ON RS485 ST SEL SW POSITION DIC DOC A B DIP SWITCHES DETAIL B +0VREF: REFERENCE OUTPUT AI+: AI, OR /AI-: AI COMMON AI+: AI, OR /AI-: AI COMMON 4V OUT: 4V AUXILIARY : I/O GROUND DIN: DIGITAL INPUT DIN: DIGITAL INPUT DIN: DIGITAL INPUT CM: COMMON FOR DI - DI 4V OUT: 4V AUXILIARY : I/O GROUND DIN4: DIGITAL INPUT 4 DIN5: DIGITAL INPUT 5 DIN6: DIGITAL INPUT 6 CM: COMMON FOR DI4 - DI6 AO+: ANALOG SIGNAL +OUT AO-/: ANALOG OUTPUT COMMON +4VIN: 4V AUXILIARY INPUT RS485: NEGATIVE RS485: POSITIVE RO/ N.C. RO/ CM RO/ N.O. RO/ N.C. RO/ CM RO/ N.O. RO/ CM RO/ N.O. SS - FOUR POSITION SEL. SW. DETAIL A SEE NOTE FAN CIRC FAN SEE NOTE RELAY OUTPUT RELAY OUTPUT RELAY OUTPUT TB 8 FAN CIRC FAN SEE NOTE TS TB SEE NOTE BUILT IN T-STAT L T.5 TB HEATER TB HEATER SEE NOTE W L T V X Y X RUN L T U SMART U V W SS SEE DETAIL A LT SEE NOTE.5 DIC X000. A A 6 DOC OL 7 8 T T T DOC.5 L L L 000X G X X RUN L T L T LT L T L T TB T L T OL L T TB T M MOTOR HP RPM AMP 000X A A 4 5 DRIVE OUTPUT DOC TB T 00X0 A A TEST 9 DRIVE INPUT DIC T T T DIS MAIN FUSED DISC. FU, FU, FU, CLASS J, TIME DELAY FFSI TB SEE NOTE J 50V, MIDGET SECONDARY FUSE TB FU6 L L L CUSTOMER SUPPLIED FREEZE/FIRE/SMOKE INTERLOCK CLASS CC PRIMARY FUSE T CONTROL TRANSFORMER CLASS CC PRIMARY FUSE FU5 LINE, PHASE, 60 HZ FU4 L/.40 L/.40 M4045 Fig.. Frame 8, Contactor Wiring Diagram
5 SMART FRAME 8 WIRING DIAGRAMS AND DIMENSIONAL DRAWINGS L L /.4 /.4 SHIELD AI 0-0 VDC OR 4-0 ma SHD AT FIELD END USE CONDUCTOR SHD, TWISTED PAIR WIRE AI 0-0 VDC OR 4-0 ma SPEED REFERENCE ST START COMMAND TB 0 DOC R 0 /.6 4/ A B VREF: REFERENCE OUTPUT AI+: AI, OR /AI-: AI COMMON AI+: AI, OR /AI-: AI COMMON 4V OUT: 4V AUXILIARY : I/O GROUND DIN: DIGITAL INPUT DIN: DIGITAL INPUT DIN: DIGITAL INPUT CM: COMMON FOR DI - DI 4V OUT: 4V AUXILIARY : I/O GROUND DIN4: DIGITAL INPUT 4 DIN5: DIGITAL INPUT 5 DIN6: DIGITAL INPUT 6 CM: COMMON FOR DI4 - DI6 AO+: ANALOG SIGNAL +OUT AO-/: ANALOG OUTPUT COMMON +4VIN: 4V AUXILIARY INPUT RS485: NEGATIVE RS485: POSITIVE RO/ N.C. RO/ CM RO/ N.O. RO/ N.C. RO/ CM RO/ N.O. RO/ CM RO/ N.O. RELAY OUTPUT RELAY OUTPUT RELAY OUTPUT L T.5 W L T V L T U SMART U V W SEE NOTE DIC T T T DOC.5 L L L L T L T L T L T TB T TB T M MOTOR HP RPM AMP L T OL L T TB T T T T DIS MAIN FUSED DISC. FU, FU, FU, CLASS J, TIME DELAY L L L LINE, PHASE, 60 HZ ALL WIRING: USE COPPER WIRE ONLY SUITABLE FOR MIN. 75 DEG. C, FIELD WIRING, NEC CLASS. MOTOR AND FEEDER WIRE SIZE MUST BE IN ACCORDANCE WITH NEC. FIELD WIRE WIRE INSIDE C/PNL OPTION NOTE : ALL PANELS SHIPPED WITH DEFAULT PROGRAMMING PARAMETERS AS FACTURY DEFAULT EXCEPT PARAMETERS M.5..6, WHICH IS SET TO SLOT 0., AND M.5..0 WHICH IS SET TO SLOT A.4. THESE CHANGES ARE FOR ENABLE FOR AUTO CONTROL. SET DIP SWITHCHES SHOWN IN DETAIL B AS REQUIRED. NOTE : IF CUSTOMER SAFETY INTERLOCK IS USED, REMOVE J. NOTE : TS, FAN STD ON ALL NEMR PNLS. FAN, ON 0, 40 & 480V. HEATER IS OPTIONAL ON ALL NEMA R PNLS. NOTE 4: RELAY R, N.O. CONTACT (PG), TERM 4, 5, 6, 7, 9, 0 - AUTO OPTION. REMOVE JUMPER J FOR MANUAL. DIN4 - RUN ENABLE, RO - DRIVE FAULT. LOCATED BEHIND COVER, RIGHT SIDE OF KEYPAD. AI AI AO TEST ON RS485 SEL SW POSITION DIC DOC DIP SWITCHES DETAIL B SS - FOUR POSITION SEL. SW. DETAIL A CUSTOMER REMOTE INDICATION TERMINALS SEE NOTE 4 - AUTO OPTION / TB TB 0 NOTE FAN CIRC FAN SEE NOTE TS TB 8 FAN TB CIRC FAN SEE NOTE TB HEATER TB BUILT IN T-STAT HEATER NOTE SEE NOTE NOTE 4 /. SEE NOTE 4 - AUTO OPTION /. A A TB 6 R TB 7 CONTROL RELAY R CUSTOMER REMOTE CONTACT Y X X SS SEE DETAIL A RUN LT 4 X A A 6 DOC 7 OL X.6 AUTO JUMPER TB X.6 R 4B TB 4 J LT X G X RUN A A 4 DRIVE OUTPUT R 4A 5 DOC 9 00X0 A A DRIVE INPUT TEST DIC SEE NOTE J 50V, MIDGET SECONDARY FUSE CUSTOMER SUPPLIED FREEZE/FIRE/SMOKE INTERLOCK FFSI TB TB FU6 CLASS CC PRIMARY FUSE T CONTROL TRANSFORMER CLASS CC PRIMARY FUSE FU5 FU4 L/.40 L/.40 M4046 Fig. 4. Frame 8, Contactor Auto-bypass Wiring Diagram
6 SMART FRAME 8 WIRING DIAGRAMS AND DIMENSIONAL DRAWINGS H H D D* W W D D* D NOTE: TWO DOES NOT COME WITH A DISCONNECT HANDLE. M87 Frame Size HP and Voltage Configuration Dimensions Weight (approx.) 08/0 460Vac W W H H D D Lb. 8 50HP 00HP Disconnect * depth of CONT only -Contactor * HP 5HP Disconnect Contactor * HP 50HP Disconnect Contactor * Fig. 5. Frame 8 NEMA : Disconnect only and Contactor Dimensional Drawing
7 A G SMART FRAME 8 WIRING DIAGRAMS AND DIMENSIONAL DRAWINGS H W BACK RESET OK LOC REM ON O D D D W STOP START I Bypass Run Run Off Test Bypass W O H M450 Frame Size HP and Voltage Configuration Dimensions Weight (approx.) 08/0 Vac 460Vac W W H H D D Lb. 8 50HP 00HP -Contactor Contactor with Auto-Bypass HP 5HP -Contactor Contactor with Auto-Bypass HP 50HP -Contactor Contactor with Auto-Bypass Fig. 6. Frame 8 NEMA: Contactor and Contactor with Auto-Bypass Dimensional Drawing
8 SMART FRAME 8 WIRING DIAGRAMS AND DIMENSIONAL DRAWINGS D EXHAUST SHROUD W I ON -/64 (56) 0 SEE NOTE H Bypass Run A Run G H Off Bypass Test FAN SHROUD D D W -/64 (56) QTY () QUARTER TURN LATCH ON FRAME 4. QTY () QUARTER TURN LATCH ON FRAME 5 AND 6. THREE POINT LATCHING WITH EXTERIOR DOOR HANDLE ON FRAME 7 AND 8. M450 Frame Size HP and Voltage Configuration Dimensions Weight (approx.) 08/0 Vac 460Vac H H W W D D Lb. 8 50HP, 60HP, 75HP 00HP, 5HP, 50HP Disconnect Only HP, 60HP, 75HP 00HP, 5HP, 50HP -Contactor HP, 60HP, 75HP 00HP, 5HP, 50HP -Contactor HP, 60HP, 75HP 00HP, 5HP, 50HP -Contactor with Auto-bypass Fig. 7. Frame 8 NEMAR: Disconnect Only, Contactor, Contactor, and Contactor with Auto- Bypass. By using this Honeywell literature, you agree that Honeywell will have no liability for any damages arising out of your use or modification to, the literature. You will defend and indemnify Honeywell, its affiliates and subsidiaries, from and against any liability, cost, or damages, including attorneys fees, arising out of, or resulting from, any modification to the literature by you. Automation and Control Solutions Honeywell International Inc. 985 Douglas Drive North Golden Valley, MN 554 customer.honeywell.com U.S. Registered Trademark 0 Honeywell International Inc M.S. 0- Printed in United States
SmartVFD Disconnect Panel Assemblies
SmartVFD Panel Assemblies INSTALLATION INSTRUCTIONS APPLICATION Only The SmartVFD Panel Assemblies channel electrical power either through or around the variable frequency drive (VFD). INSTALLATION When
More informationH7625A, H7635A Humidity/Temperature Sensors
H765A, H7635A Humidity/Temperature Sensors WALL-MOUNT MODELS APPLICATION The H765A, H7635A Wall-Mount Humidity/Temperature Sensors are universal Relative Humidity transmitters that can be powered with
More informationSED2 Variable Frequency Drives with Electronic (E) Bypass Options
SED2 Variable Frequency Drives with Electronic (E) Options Description The E- Options are companion packages for the family of SED2 Variable Frequency Drives (s). For information on the family of SED2
More informationH7625B; H7635B,C; H7655B Duct-Mount and Outdoor-Mount Humidity/Temperature Sensors
H765B; H7635B,C; H7655B Duct-Mount and Outdoor-Mount Humidity/Temperature Sensors APPLICATION The H765B, H7635B, H7655B Duct-Mount and H7635C Outdoor-Mount Humidity/Temperature Sensors are universal Relative
More informationSED2 Variable Frequency Drives Conventional Bypass (C-Bypass) Options
Submittal Sheet SED2 Variable Frequency Drives Conventional Bypass (C-Bypass) Options Description The Bypass Options are companion packages for the family of SED2 Variable Frequency Drives. For information
More informationSLATE. Digital I/O Module INSTALLATION INSTRUCTIONS R8001D4001
SLATE Digital I/O Module R8001D4001 INSTALLATION INSTRUCTIONS Scan for more information Application SLATE brings configurable safety and programmable logic together into one single platform. The platform
More informationSED2 VFD NEMA Type 3R Bypass/Air Conditioner
SED2 VFD NEMA Type 3R Bypass/Air Conditioner Description The NEMA Type 3R Bypass with Air Conditioner allows SED2 to be employed in a harsh environment. The SED2 is designed specifically for HVAC applications
More informationBT300 HVAC Drives Electronic Bypass (E-Bypass) Options
BT300 HVAC Drives Electronic Bypass (E-Bypass) Options Description The BT300 Electronic Bypass (E-Bypass) Options are companion packages for the family of BT300 Variable Frequency Drives (VFDs). For information
More informationInstallation Manual Updated May 2017
Code No. LIT-12012114 Installation Manual Updated May 2017 JC-VSD Factory Packaged (FP) Series II drive frames 4 8, Type 1 and 3R Johnson Controls variable speed drives Disclaimer of warranties and limitation
More informationGlobal Field Devices COMMERCIAL HVAC COMPONENTS ENGINEERED FOR SUCCESS. Application And Selection Guide
Global Field Devices COMMERCIAL HVAC COMPONENTS ENGINEERED FOR SUCCESS Application And Selection Guide About valve selection The valve selection section is constructed in one of two ways: For unassembled
More informationPGR-4700 MANUAL SENSITIVE GROUND-FAULT RELAY
Tel: +1-800-832-3873 E-mail: techline@littelfuse.com www.littelfuse.com/pgr-4700 PGR-4700 MANUAL SENSITIVE GROUND-FAULT RELAY REVISION 2-B-032218 Copyright 2018 by Littelfuse, Inc. All rights reserved.
More informationE510. Compact Drive IP 20/ NEMA HP (230V) 1-75 HP (460V)
E510 Compact Drive IP 20/ NEMA 1 0.5-40 HP (230V) 1-75 HP (460V) Control Mode Application & Selection Guide The E510 compact AC Drive is an easily configurable product that controls many motor driven applications.
More informationT775S Series 2000 Expansion Module
T775S Series 000 Expansion Module INSTALLATION INSTRUTIONS PRODUT DESRIPTION The T775S008 Relay Expansion Module is a four relay device for use with the T775L007 and T775P00 Series 000 Electronic Stand-Alone
More informationN20010-SER. NON-SPRING RETURN DAMPER ACTUATOR 20 Nm (177 lb-in) FOR ADJUSTABLE MODULATING CONTROL SPECIFICATIONS GENERAL FEATURES PRODUCT DATA
N20010-SER NON-SPRING RETURN DAMPER ACTUATOR 20 Nm (177 lb-in) FOR ADJUSTABLE MODULATING CONTROL GENERAL These direct-coupled damper actuators provide adjustable modulating control for: air dampers, VAV
More informationSED2 VFD NEMA Type 3R and 3R Harsh Environment (3RHE) Bypass Operating Instructions
SED2 VFD NEMA Type 3R and 3R Harsh Environment (3RHE) Bypass Operating Instructions Item Number 125-3377, Rev. FA SED2 VFD NEMA Type 3R and Type 3R Harsh Environment (3RHE) Bypass Operating Instructions
More informationSmartVFD HVAC and BYPASS
SmartVFD HVAC and BYPASS The Smart Choice for Energy Savings. Saving Energy the Smart Way Buildings consume more than 70 percent of the electricity produced in North America and roughly half of that is
More informationStandard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter
Standard Options Model 4100 Position Indicating Meter A percent-of-full-travel meter is supplied with a trim potentiometer resistor, terminal block and connectors. A potentiometer is required in the actuator
More informationVariable Frequency Drives
Variable Frequency Drives SmartVFD Selection Guide The Smart Choice for Smart Buildings SmartVFD Saving Energy the Smart Way Buildings consume more than 70% of the electricity produced in North America
More informationBaltimore Aircoil Company
Baltimore Aircoil Company VFD Startup Guide TABLE OF CONTENTS: A. Verifying Power and Control Wiring...1 B. Setting the VFD Parameters...2 C. Reentering Startup Wizard After Initial Setup...5 D. Starting
More informationT7350 Keypad Configuration
Setup Using Keypad T7350 Keypad Configuration QUICK GUIDE NOTE: Refer to Fig. 1 and Table 2 for keypad description and details. A combination of key presses are required to use the Installer Setup feature:
More informationPGR-6101 MANUAL GROUND-FAULT & INSULATION MONITOR
Tel: +1-800-832-3873 E-mail: techline@littelfuse.com www.littelfuse.com PGR-6101 MANUAL GROUND-FAULT & INSULATION MONITOR Revision 0-C-041918 Copyright 2018 by Littelfuse, Inc. All rights reserved. Document
More informationWiring Diagrams UNITS WITH STARTING SERIAL NUMBER 3507Q
AQUASNAP 30RB060-390 Air-Cooled Liquid Chillers with COMFORTLINK Controls 60 Hz Wiring Diagrams UNITS WITH STARTING SERIAL NUMBER 3507Q INDEX* POWER SCHEMATICS 30RB Unit Size Voltage Figure Number Label
More informationP216 Series Condenser Fan Speed Controller
P216 Series Condenser Fan Speed Controller Installation Instructions P216xxx-x Part No. 24-85895-18, Rev. D Issued 27 August 2015 Applications Refer to the QuickLIT website for the most up-to-date version
More informationWiring Diagrams DIAGRAM INDEX. POWER SCHEMATICS Unit 30GXN,R Voltage Figure Number
30GXN,R Sizes 080-528 Air-Cooled Chillers with ComfortLink Controls 50/60 Hz Wiring Diagrams DIAGRAM INDEX POWER SCHEMATICS Unit 30GXN,R Voltage Figure Number Label Diagram No. 30GX 080-178* ALL 1 505429
More informationCTR21, CTR22, CTR23, and CTR24 Wall Modules
CTR21, CTR22, CTR23, and CTR24 Wall Modules FEATURES SPECIFICATION DATA The CTR21, CTR22, CTR23, and CTR24 family of wall modules include: Models with setpoint adjustment. Models with occupied/unoccupied
More informationT7560A,B,C Digital Wall Module
T7560A,B,C Digital Wall Module INSTALLATION INSTRUCTIONS CAUTION: This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the Installation
More informationSmartVFD HVAC232/402 GENERAL FEATURES SPECIFICATIONS. Frequency drives. Mains Connection Input voltage U in : Supply Network Networks:
Frequency drives GENERAL PRODUCT DATA SmartVFD HVAC232/402 Variable speed drives for induction- and permanent magnet motors, with built-in RFI filters. EMC and LVD compliant. SmartVFD HVAC232/402 variable
More informationExpandable Power Systems
Expandable Power Systems Installation Guide Models Include: Maximal11EV 12VDC @ 4A or 24VDC @ 3A. 12VDC @ 4A or 24VDC @ 3A. Maximal33EV 12VDC or 24VDC @ 6A. 12VDC or 24VDC @ 6A. Maximal37EV 24VDC @ 10A.
More informationPGR-6100 MANUAL GROUND-FAULT & INSULATION MONITOR
Tel: +1-800-832-3873 E-mail: techline@littelfuse.com www.littelfuse.com/pgr-6100 PGR-6100 MANUAL GROUND-FAULT & INSULATION MONITOR Revision 2-C-050818 Copyright 2018 Littelfuse All rights reserved. Document
More informationAnalog Output Module Installation Instructions
Description The Analog Output Module is a component of Novar Controls Spectrum Refrigeration Control System. It produces a varying analog voltage signal to control proportional modulating devices. Control
More informationINSTRUCTION SHEET. Eaton Logic Controller ELCB Controllers
2010-12-10 5011699201-PBB1 Eaton Logic Controller ELCB Controllers INSTRUCTION SHEET [Applicable Controllers] ELCB-PB10 ELCB-PB14 ELCB-PB20 ELCB-PB30 ELCB-PB40 IL05001005E 002-1310020-02 Thank you for
More informationUNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN
1 2 8 4 AI6 R R Installation Bulletin UNT1100 Issue Date 0309 UNT1100 Series Introduction The Unitary (UNT) controller (UNT1100 Series) is a digital controller with applications for air handling units,
More informationSubmittal Data Sheet WAGO Node for itm
The WAGO Node integrates ancillary equipment into the Intelligent Touch Manager (itm) DCM601A71 with the use of DI, DO, AI and AO signals. It provides monitoring and control of non-daikin equipment via
More informationPump Data Sheet - Patterson HVAC Pumps Company: Intermountain Hydron Name: Cache County Mountain Crest Date: 09/24/2018
Pump Data Sheet - Patterson HVAC Pumps Company: Intermountain Hydron Name: Cache County Mountain Crest Date: 09/24/2018 Tags: P-8 1800RPM Premium Efficient Motor 460/3/60 Pump and Motor Weight: 183lbs
More informationN20, N34 Series Non-Spring Return Direct Coupled Actuators
N0, N Series Non-Spring Return Direct Coupled Actuators INSTALLATION INSTRUCTIONS APPLICATION N0 and N Series Non-Spring Return Direct Coupled Actuators (DCA) are used within heating, ventilating, and
More information2 Table of Contents 1. TABLE OF CONTENTS. 1. Table of Contents Introduction Wiring Diagram Terminals Review...
TPR-6 Temperature Protection Relay Instruction Manual Ver. June 1 st 2010 2 Table of Contents 1. TABLE OF CONTENTS 1. Table of Contents... 2 2. Introduction... 3 3. Wiring Diagram... 5 4. Terminals Review...
More informationQuantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III
Compact DC Drive Package The delivers a DC drive package that integrates the intelligence of the Mentor II with a space saving design that incorporates many accessories typically required in the North
More informationQuick Start Guide For GVX9000 AF Drives
Quick Start Guide For GVX9000 AF Drives June 2006 New Information 5011646300 00GQ MN04000002E June 2006 Step 1 Wiring Hazardous High Voltage HIGH VOLTAGE! Motor control equipment and electronic controllers
More informationUC-2000 Installation Manual Unicorn Computers Technology Limited
UC2000 Installation Manual Copyright 2003. All rights reserved. Table of Contents Specifications 2 Enclosure for the UC2000 Controller 3 Unicorn Access Control System Configuration 4 UC2000 Controller
More informationINSTRUCTION MANUAL IM253 R0. AquaStart COMBINATION SOFT STARTERS START-UP MANUAL
INSTRUCTION MANUAL IM253 R0 AquaStart COMBINATION SOFT STARTERS START-UP MANUAL INDEX Power Connections...3 Basic Wiring...4 Start-Up By Voltage Ramp...5 Local / Remote Modes...6 Control and Signal Connections...6
More informationFor full product information, visit Use the SpeedSpec code or scan the QR Code for quick access to the specific web page.
R Safety Monitoring Relays For full product information, visit www.sti.com. Use the SpeedSpec code or scan the QR Code for quick access to the specific web page. Dual-Channel Safety Monitoring Relay Power
More informationWhat is Zip? Zip Modules... 6 Zip Network... 6 Zip Master Quick Start... 7
Zip Manual Control systems need connections to the real world -- inputs to measure the environment and outputs to control equipment. Zip is North s measurement and control system. This document relates
More informationDVFP Series Variable Frequency Drive - Product Manual. pg. 1
pg. 1 Set Up Instructions for DVFP Inspect the packaging of the equipment to confirm that nothing was damaged during shipping. Remove the system from the packaging. Make sure everything is included and
More informationPS-4100 POWER SUPPLY MANUAL
PS-4100 POWER SUPPLY MANUAL Manual Part Number 180-0573 December 7, 2006 TABLE OF CONTENTS TITLE PAGE Table of Contents... 2 List Of Figures... 3 1. Introduction... 4 1.0. General... 4 1.1. Features...
More informationMG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD
United States MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD Product Information Features and Specifications For Use With: OEM Panels Approvals: UL
More informationUser s Manual E-Clipse Bypass Configurations (BCR, BDR, VCR, or VDR) for ACH550 Drives (1 400 HP)
User s Manual E-Clipse Bypass Configurations (BCR, BDR, VCR, or VDR) for ACH550 Drives (1 400 HP) ABB ii E-Clipse Configurations for ACH550 Drives ACH550 Drive Manuals GENERAL MANUALS ACH550-UH HVAC User's
More informationPowerFlex 400 AC Drive Guide Specification
PowerFlex 400 AC Drive Guide Specification Adjustable Frequency Drives with Bypass 3.0 50HP @ 208V AC 3.0 350HP @ 480V AC PART 1 GENERAL 1.01 Quality Assurance A. The manufacturer shall have minimum 5
More informationCompact I/O Module XIO-4AO LON ANALOG OUTPUT MODULE
ompact I/O Module XIO-4AO LON ANALOG OUTPUT MODULE INSTALLATION INSTRUTIONS Terminal Blocks: Supply and Bus: 16 AWG (1.5 mm²). (terminal block and strapping plug included with packing). Analog Outputs:
More informationHow to control and monitor up to 16 Motor Insight motor protection relays via an HMi and Modbus serial
Application The purpose of this application example is to demonstrate how to use the HMi electronic operator interface family to control and monitor up to 16 Motor InsightT motor protection relays via
More informationRTK3 Logic Controller User Manual Revised
RTK3 Logic Controller User Manual Revised 6-24-08 1 of 16 svn://software/hardware/rtk3/docs/rtk3_man.doc MRR 6/24/08 9:03 AM Overview The RTK3 is intended to simplify and expedite control wiring. Centroid
More informationover time. Improper wiring practices could result in drive malfunction due to loose terminal connections. Control Circuit Terminal Block Functions Dri
Figure 3.14 Main speed frequency reference. Multi-function programmable Safety input Forward run/stop Reverse run/stop External fault Fault reset Multi-step speed 1 main/aux switch Multi-step speed 2 Jog
More informationSED2 Variable Frequency Drives
Building Technologies SED2 Variable Frequency Drives More standard features Means better control of HVAC applications The global leader in Heating, Ventilation and Air Conditioning (HVAC) products and
More informationXT-9100 Technical Bulletin
System 9100 Technical Manual 636.4 Technical Bulletins Section Technical Bulletin Issue Date 0896 XT-9100 Technical Bulletin XT-9100 Extension Module/XP-910x Expansion Modules Page 3 Introduction 3 SX
More informationUser s Manual. ACS550-PD 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual
User s Manual ACS550-PD 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual 2 ACS550-PD 3R Irrigation Packaged Drive ACS550 Drive Manuals GENERAL MANUALS ACS550-U1 User s Manual (1 200 HP)
More informationSED2 Variable Frequency Drives
SED2 Variable Frequency Drives Startup Procedure and Checklist Document No. 155-718 Table of Contents Prerequisites...1 Preparing for SED2 VFD Startup...1 HVAC Startup Procedure for SED2 with Bypass Option...4
More informationP216. Condenser fan speed controller. Product bulletin. Features
P216 Condenser fan speed controller Product bulletin These controllers are designed for speed variation of single phase motors, especially for fan speed control on air cooled condensers. Head pressure
More informationInstallation and Wiring
Wiring 2 2 Plan for Safety Safety Techniques WARNING: Providing a safe operating environment for personnel and equipment is your responsibility and should be your primary goal during system planning and
More informationF510 Fan & Pump AC Drive
F510 Fan & Pump AC Drive 5-150 HP (230V) n 5-250 HP (460V) Control Mode Application & Selection Guide The F510 Fan and Pump AC Drive is an easily configured and versatile drive product that will control
More informationMulti-instrument Communication, MIC-2 MKII DIN Quick Start Guide
Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide Warnings and legal information Installation and terminals Communication I/O options Alarming Utility software More information Specifications
More informationVersatile Safety Interlock Switch with Guard Door Locking
R Conforms to EN1088, EN60947-5-1, EN292, EN60204-1 UL and C-UL listed, BG approved Versatile Safety Interlock Switch with Guard Door Locking High locking force of 450 pounds locks guard door shut until
More informationINSTALLATION INSTRUCTIONS
LIGHTING CONTROL PANELS 16 AND 24 RELAYS INSTALLATION INSTRUCTIONS INSTALLATION OVERVIEW The installation instructions contained in this document are provided as a guide for proper and reliable installation.
More informationT7350 PDA Configuration
T7350 PDA Configuration QUICK START GUIDE SETUP 1. Connect PDA to 50000083-001 Thermostat Interface Module (TIM) using PDA serial cable. 2. Ensure the PDA serial cable and the PDA remain connected. 3.
More information4/8/ nd Annual OTCO WW Workshop W/WW Product Overview ACQ550. ABB Slide 1
4/8/2015 52 nd Annual OTCO WW Workshop W/WW Product Overview ACQ550 Slide 1 Drive Basics Why Use Adjustable Speed Drives? Reduced Energy Consumption Improved Process Control / Efficiency Increased Product
More informationPGR-3200 MANUAL INSULATION MONITOR
Tel: +1-800-832-3873 E-mail: techline@littelfuse.com www.littelfuse.com PGR-3200 MANUAL INSULATION MONITOR REVISION 3-E-040918 Copyright 2018 by Littelfuse, Inc. All rights reserved. Document Number: PM-1025-EN
More informationHoneywell. Installation manual. SmartVFD HVAC Variable Frequency Drives for Variable Torque Applications
Honeywell Installation manual SmartVFD HVAC Variable Frequency Drives for Variable Torque Applications 38-00007-03 Honeywell 0 INDEX Document: DPD00323D Version release date: 18.1.18 1. Safety...2 1.1
More informationPGR-4300 MANUAL GENERATOR GROUND-FAULT RELAY
Tel: +1-800-832-3873 E-mail: techline@littelfuse.com www.littelfuse.com PGR-4300 MANUAL GENERATOR GROUND-FAULT RELAY REVISION 3-B-041318 Copyright 2018 by Littelfuse, Inc. All rights reserved. Document
More informationProduct Information SIMATIC S Digital Output Module SM 322; DO 16 UC24/48 V
Product Information SIMATIC S7-300 Digital Output Module SM 322; DO 16 UC24/48 V X 2 as of Version 3 4 New Digital Output Module Available The S7-300 Digital Output Module SM 322; DO 16 UC24/48 V has been
More informationBulletin 194R Fused and Non-Fused Disconnects Product Selection
Product Selection 4th Pole Modules Maximum Hp Ratings Rated 1-Phase (60 Hz) -Phase (60 Hz) DC Current [A] 1V 240V 240V 480V V 12V V Ref. Non-d 0 2 7. 1 A2 194R-0-NN 60 1 0 40 B2 194R-60-NN UL Class CC
More information920 Remote Control (RC) Switches
920 Remote Control (RC) Switches ASCO is the global leader in power switching and controls ASCO 920 PRODUCT SPECIFICATIONS SWITCH ONLY (PANELBOARD MOUNTING) 1,2,3 () DIMENSIONS, IN.(MM) WIDTH HEIGHT DEPTH
More information9/7/2010. Chapter , The McGraw-Hill Companies, Inc. MOTOR SYMBOLS. 2010, The McGraw-Hill Companies, Inc.
Chapter 2 MOTOR SYMBOLS 1 Symbols are used to represent the different components of a motor control system. Symbols sometimes look nothing like the real thing, so we have to learn what the symbols mean.
More informationDESIGN GUIDE FOR INFINITY SYSTEMS
Doc. 6001564 Rev B DESIGN GUIDE FOR INFINITY SYSTEMS WITH STAND ALONE OR MULTI-LINK LINK FIRMWARE TABLE OF CONTENTS 1. CABINET DIMENSIONS...3 2. WIRE CHART...3 A. CABLING TO THE MAIN PROCESSOR BOARD...
More information60103 Circuit Breaker
6003 Circuit Breaker United States MINIATURE CIRCUIT BREAKER, 20/240VAC, 2A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Circuit Breaker Type: Standard
More informationOVERLOAD RELAYS POWER & ACTUATION PROVEN. series
POWER & ACTUATION OVERLOAD RELAYS series Need reliable, accurate overload and phase-loss protection for your motors? c3controls Series Bimetallic Overload Relays provide unmatched protection and can be
More informationHomeWorks Remote Power Feed-Through Panels
power feed-through panels are available in two different sizes, each of which may be either surface-mounted or recess-mounted, in an electrical closet or other equipment room. The number of remote power
More informationJK Series POWER DISTRIBUTION. Solid State Starters Medium Voltage A
POWER DISTRIBUTION JK Series Solid State Starters Medium Voltage 200-400-600-720A SOLID STATE STARTER JKSSS4+ Series The JKSSS Series of motor starter is the result of extensive research and development.
More informationVSD Series Quick Start Guide
Powered by Eaton s Technology Open Drive Bypass Drive NEMA Type 12 NEMA Type 3R IMPORTANT: This guide is intended to provide a quick reference to the VSD Series drive s Application Software features for
More informationMulti-instrument Communication, MIC-2 MKII DIN Quick Start Guide
Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide Warnings and legal information Installation and terminals Communication I/O options Alarming Utility software More information Specifications
More informationSMVector Additional I/O Module Installation and Operation Manual
SMVector Additional I/O Module Installation and Operation Manual About These Instructions This documentation applies to the optional Additional I/O module for the SMVector inverter and should be used in
More informationSORDS ELECTRIC ~ MA7200. Sensorless Vector AC Inverter.
www.sordselectric.com MA7200 Sensorless Vector AC Inverter Features and Benefits Sensorless Vector The MA7200 has precise speed and torque control for the most demanding system performance and simple set-up
More informationSPX 1hr product overview Eaton Corporation. All rights reserved.
SPX 1hr product overview 2012 Eaton Corporation. All rights reserved. Eaton Product Offering Machinery OEM Drives DE1, DC1, DE1, DA1, M-Max HVAC Drives H-Max 0.25HP 25HP 1HP 250HP General Purpose Industrial
More informationFUSERBLOC UL Fusible disconnect switches UL and CSA from 30 to 800 A
Fuse protection The solution for > Motor on-load disconnect > Protection of industrial cabinet > Electrical distribution ul_004_a Strong points fuser-ul_006_a Function FUSERBLOC UL fusible disconnect switches
More informationac wave 2 supply ( analog device )
ac wave 2 supply ( analog device ) «SPECIFIC PRODUCT SECTION» Instruction and user s manual Release 2.1 00/05 REEL S.r.l. Electronic Power Drives Via Riviera Berica, 42 36024 Ponte di Nanto - Vicenza -
More informationT7560A1036 Digital Wall Module
T7560A1036 Digital Wall Module HONEYWELL EXCEL 5000 OPEN SYSTEM BEFORE INSTALLATION All wiring must comply with local electrical codes and ordinances or as specified on installation wiring diagrams. T7560A1036
More informationZC Series Zone Monitoring Controllers
ZC Series Zone Monitoring Controllers Installation Instructions MANUAL Reset Controllers Model Description Part Number ZC-1 1 Zone Controller 0421 ZC-2 2 Zone Controller 0422 ZC-3 3 Zone Controller 0423
More informationAirTest Model CN9000 Series Sensor Controller
AirTest Model CN9000 Series Sensor Controller AirTest Model CN9000 Series Sensor Controller THEORY OF OPERATION A basic CN9000 configuration consists of Input/Process/Display combination modules, a 3 relay
More informationSED2 Variable Frequency Drives Startup, Operation, and Maintenance Manual
SED2 Variable Frequency Drives Startup, Operation, and Maintenance Manual Item Number 125-3201, Rev. 012 SED2 Variable Frequency Drives Startup, Operation, and Maintenance Manual NOTICE The information
More informationASCO 920 Remote Control (RC) Switches
Maximum reliability and excellent value ASCO 920 Remote Control (RC) Switches ASCO 920 Remote Control Switch in Type Enclosure The ASCO 920 is designed as a feeder disconnect switch for load capacities
More informationSylk I/O Devices APPLICATION FEATURES PRODUCT DATA
Sylk I/O Devices APPLICATION PRODUCT DATA The Sylk IO devices are part of the Spyder family. The three IO devices are designed to seamlessly integrate with Spyder with relay controllers using only Sylk
More informationCFW-09HD LINE DC LINK POWER SUPPLY
CFW-09HD LINE DC LINK POWER SUPPLY CFW-09HD Line Addendum to the CFW-09 Manual Addendum to the CFW-09 Manual CFW-09HD Line I. GENERAL INFORMATION This addendum has information about the CFW-09HD line
More informationSafety Mats & Area Guarding
Safety Mats & Area Guarding MC Controllers MC MC, MC and MC Series Safety Mat Controllers The MC Series safety mat controllers are used in conjunction with a four-wire, normally open, safety mat where
More informationFirmware Manual - EC Series Drives
1 Firmware Manual - EC Series Drives Doc Ver 1.01 Firmware ver: EC series drives For installation details refer to Hardware Manual Safety: Read safety instruction in hardware manual before installation
More informationService Instructions. Conductor 420
Service Instructions Conductor 420 Listed, File No. E195547 Input: 480 VAC, 50/60 HZ. (Operating range 380-480 VAC) 20 AMP MAX OUTPUT W/25 AMP FUSE Output: 0-90% of Input Voltage Table of Contents General
More informationPFC Mini TM Power Factor Corrected AC-DC Switchers
21 PFC Mini TM Power Factor Corrected AC-DC Switchers Overview Technical Description The PFC Mini is an extremely low profile switching power supply that combines the advantages of power factor correction,
More informationDRIVE STARTUP MANUAL Magnetek HPV900-S2 Drive
DRIVE STARTUP MANUAL Magnetek HPV900-S2 Drive PM Installation www.smartrise.us 2601 Fair Oaks Blvd., Sacramento, CA 95864 916.457.5129 Magnetek HPV900S2 Drive EQUIPMENT/SETTINGS VERIFICATION Verify that
More informationEMS467 Monitoring System. Installation and Operations Manual Section 40
EMS467 Monitoring System Installation and Operations Manual 00-02-0672 01-26-10 Section 40 In order to consistently bring you the highest quality, full featured products, we reserve the right to change
More informationBFBP21 Tech Sheet. Customer: Bullfrog Spas. Part Number: X1 825 Incoloy Custom Box Overlay Box Overlay Part Number 46091
BFBP21 Tech Sheet Customer: Bullfrog Spas Part Number: 56342-01-X1 825 Incoloy Custom Box Overlay Box Overlay Part Number 46091 UL System Model: BP21-BFBP21-AS Software Version ID: M100_225 V13.0 Software
More informationZenith DS9000 Dispensing System
Page Date: 04/2009 Zenith DS9000 Dispensing System Installation & Operation Manual Page 2 Table of Content Introduction... 3 Control Specification... 4 Wiring Diagram... 5 Wiring Instructions... 6 Field
More informationSDM-6RO. Expansion Module 6 relay outputs. Manufactured for
Version 1.0 5.02.2014 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have
More informationSDM-8AO. Expansion Module 8 analog outputs. Manufactured for
Version 1.0 16.05.2014 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have
More informationOperating Instructions. For. Level Control Module. Model SSR 1000
Operating Instructions For Level Control Module Model SSR 1000 SSR Operation Instructions Rev. 1 Jan 01 Page 1/7 1. Note Please read and take note of these operating instructions before unpacking and commissioning.
More information