PC Vision Wiring Guide

Size: px
Start display at page:

Download "PC Vision Wiring Guide"

Transcription

1 PC Vision Wiring Guide TTL TTL OPTO OPTO +V S T S T S+ S- T+ T- S+ S- T+ B- +V POWER OUTPUT +V POWER OUTPUT STRB/TRIG STRB/TRIG STROBE TRIGGER O STROBE TRIGGER A/B A/B A/B A/B +V A B A B A+ A- B+ B- A+ A- B+ B- TTL I/O LVDS LVDS CHASSIS J P G P April

2 PC Vision Wiring Guide About this Manual The PC Vision Wiring Guide is a supplemental document that provides illustrated examples of how to solve common wiring problems when using Cognex PC Vision products. Unless otherwise stated, all of the products and accessories described in this document are supported by both VisionPro and CVL. For detailed information, including pin-out tables, electrical and mechanical characteristics, environmental requirements, certification information, and detailed circuit diagrams, refer to the hardware manuals for the products included on the product DVD and installed on your PC by default. You can also obtain this documentation from Cognex s support web site ( and through the links in this document. The wiring configurations shown in this document are examples of how you can connect Cognex equipment to common devices such as photoelectric sensors, PLC input and output modules, and stack lights. There are many additional methods that you can use to connect this equipment to these and other devices; consult the reference documentation for detailed information. Copyright Cognex Corporation All Rights Reserved Table of Contents MVS-8 and MVS-86 I/O Products FireWire and GigE Vision Cameras Point Grey Research Flea Trigger and Strobe 6 Basler scout (FireWire) Trigger and Strobe 8 Basler scout and pilot (GigE Vision) Trigger and Strobe Basler ace (GigE Vision) Trigger and Strobe Basler runner (GigE Vision) Line Scan General-Purpose I/O Modules General-Purpose Digital I/O (PCI Bus Adapter) 6 General-Purpose Digital I/O (USB Adapter) 8 MVS-8 I/O MVS-8 Opto-Isolated Wiring MVS-8 TTL Wiring MVS-86 I/O MVS-86 Opto-Isolated Trigger and Strobe (Area Scan) MVS-86 TTL Trigger and Strobe (Area Scan) 6 MVS-86 Opto-Isolated General-Purpose I/O 8 MVS-86 Single LVDS Encoder (Line Scan) MVS-86 Dual LVDS Encoder (Line Scan) MVS-86 Single/Dual TTL Encoder (Line Scan) Table of Contents

3 MVS-8 and MVS-86 I/O Products MVS-8 and MVS-86 I/O Products I/O Kit/ Product ID Provides Includes OUT OUT OUT OUT 6 MVS-8 I/O Modules, s, and Accessories 6 bidirectional TTL lines Breakout box +V TTL TTL S T S OPTO T STRB/TRIG STRB/TRIG A/B A S+ B A TTL I/O B S- STROBE A/B T+ OPTO T- TRIGGER O S+ A+ A- B+ S- STROBE A/B T+ B- TRIGGER A/B B- LVDS A+ A- B+ B- B B B B B B B6 B7 G NC NC NC NC LVDS IO-TTL-8 +V +V POWER OUTPUT +V POWER OUTPUT PN TTL I/O Kit Component Part Number T S T S T S T S G NC NC NC NC CHASSIS J 8-7-R INPUTS TO OUTPUTS FROM -89-R Breakout box 8-7-R -+ IN -+ IN -+ IN -+ IN -+ IN -+ IN -+ IN 6 -+ IN 7 INPUTS TO -+ OUT -+ OUT -+ OUT -+ OUT -+ OUT -+ OUT -+ OUT 6 -+ OUT 7 GROUND OUTPUTS FROM 8 bidirectional TTL lines opto-isolated inputs opto-isolated outputs Breakout box -+ IN -+ IN -+ IN -+ IN -+ IN -+ IN -+ IN 6 -+ IN 7 IO-OPTO-TTL-8 8 opto-isolated inputs 8 opto-isolated outputs -+ OUT -+ OUT -+ OUT -+ OUT -+ OUT -+ OUT -+ OUT 6 -+ OUT 7 TTL plus Opto I/O Kit IO-OPTO-8-9-R GROUND Opto I/O Kit Y-cable -99-R -camera breakout cable ( ) --R Connect four cameras to MVS-8 series --R -camera breakout cable with power --R Connect four cameras to MVS-8 series --R -camera breakout cable -96-R Connect two cameras to MVS-8Le -96-R MVS-86 I/O Modules, s, and Accessories Product ID CIO-86-TTL Provides Includes Component Part Number OUT OUT OUT OUT 6 I/O Kit/ TTL Option I/O Module TTL or opto-isolated trigger inputs or TTL encoder inputs Breakout box +V +V POWER OUTPUT +V POWER OUTPUT +V TTL TTL S T S OPTO T S+ A/B A S- STROBE STRB/TRIG STRB/TRIG A/B B A A+ B T+ OPTO T- TRIGGER O S+ S- STROBE A/B TTL I/O A- B+ T+ B- TRIGGER A/B B- A+ LVDS A- B R B- LVDS CHASSIS J OUT OUT OUT OUT 6 --R LVDS Option I/O Module CIO-86-LVDS TTL or opto-isolated trigger inputs TTL or opto-isolated strobe outputs LVDS encoder input Breakout box +V +V POWER OUTPUT +V POWER OUTPUT +V TTL TTL S T S OPTO T S+ A/B A S- STROBE STRB/TRIG STRB/TRIG A/B B A T+ OPTO T- TRIGGER O S+ S- STROBE A/B A+ B TTL I/O A- B+ T+ B- TRIGGER A/B B- A+ LVDS A- B R B- LVDS CHASSIS J OUT OUT OUT OUT 6-9-R Dual-LVDS Option I/O Module CIO-86-DLVDS or LVDS encoder inputs Breakout box +V +V POWER OUTPUT +V POWER OUTPUT +V TTL TTL S T S OPTO T STRB/TRIG STRB/TRIG A/B A S+ A B S- STROBE A/B B TTL I/O T+ OPTO T- TRIGGER O S+ A- B+ S- STROBE A/B A+ T+ B- TRIGGER A/B B- LVDS A+ A- B R B- LVDS CHASSIS J Dual-LVDS Trigger Kit General Purpose I/O Camera Link s CIO-86-DLVDSTRG CIO-86-GPIO TTL triggers for use with Dual-LVDS encoder inputs (use with CIO-86-DLVDS) 8 8 TTL trigger inputs TTL strobe outputs opto-isolated input lines opto-isolated output lines -8-R /faceplate --R Wiring block 9- Extension cable 8- Wiring blocks 9- Extension cables 8- s/faceplates --R CCB-86-MS-nn (nn = or ) Non-PoCL high-flex mini-to-standard connectors ( and ) CCB-86-MS-nn (nn = or ) 8- ( ) 8- ( ) Non-PoCL high-flex standard-to-standard connectors ( and ) 8- ( ) 8- ( ) CCL-POCL-M- PoCL-compatible high-flex cable, mini-to-standard connectors ( ) CCL-POCL-M-

4 Point Grey Research Flea Trigger and Strobe The Point Grey Research Flea is a FireWire-B camera providing trigger and strobe support. The camera provides general-purpose I/O lines, but these are not available through Cognex I/O programming interface. Refer to the camera documentation for information on using these lines. A Cognex FireWire-B interface card is recommended. You can use a FireWire-A card (CFA- IC) with B-to-A adapter (CFA-B-ADPTR), but you will be limited to FireWire-A speed. The CFA-IC and CFB-IC-PCI adapters use the PCI bus. You can also use the CFB-ICE adapter that uses the PCIe bus and provides two backward-compatible FireWire-B ports and one FireWire-A port. The wiring diagram on the right includes a FireWire-B hub (CFB-HUB) that supports the use of multiple cameras on one adapter camera port. Additional hubs can be cascaded for supporting more cameras. Hubs are also used for extending the distance between a camera and the adapter. Most single camera systems will use the CFB-CBL- cable, connecting the adapter and camera with no hub. The trigger and strobe I/O (CFB-IO-CBL-FLEA) provides access to trigger and strobe connections. Note that all four I/O lines are green; the lines are identified by numeric flags attached to the individual wires. A -foot version of the cable (CFB-IO-CBL-FLEA-) is also available. All trigger and strobe lines use TTL-level signals. Pin Wire Color Signal Green Trigger Green Strobe Green General I/O Green General I/O FLEA Camera Trigger Ground Strobe FireWire-B Hub (CFB-HUB) FireWire 9B Adapter (CFB-IC-PCI) CFB-IO-CBL-FLEA cable CFB-CBL- cable FLEA Camera + VDC - Point Grey Research Flea Trigger and Strobe Black Ground 6 Black Ground 7 White External camera power (8- A) 8 Red Power for external devices (. VDC, max ma) See VisionPro or CVL documentation topics on FireWire acquisition. See the FireWire Cameras manual supplied with VisionPro. See the CCF (Camera Configuration File) for this camera for additional information. Source + See the Cognex FireWire white paper available at : See the Camera hardware manual at: + VDC - Strobe Trigger 6 7

5 Basler scout (FireWire) Trigger and Strobe The Basler scout FireWire-B camera provides trigger and strobe support. The camera provides general-purpose I/O lines, but these are not available through Cognex I/O programming interface. Refer to the camera documentation for information on using these lines. The standard I/O cable (CFB-IO-CBL-SCOUT) is intended for use in lowvoltage TTL (V) and CMOS (.V) environments only. Use the V cable (CFB-IO-CBL-BAS-V) with V equipment such as PLCs and relays. A Cognex FireWire-B interface card is recommended. You can use a FireWire-A card (CFA- IC) with B-to-A adapter (CFA-B-ADPTR), but you will be limited to FireWire-A speed. The CFA-IC and CFB-IC-PCI adapters use the PCI bus. You can also use the CFB-ICE adapter that uses the PCIe bus and provides two backward-compatible FireWire-B ports and one FireWire-A port. You can use a FireWire-B hub (CFB-HUB) that splits one input line into multiple output lines for supporting multiple cameras on one adapter camera port. Additional hubs can be cascaded for supporting several cameras or for extending the distance between a camera and the adapter. See page 7 for an example wiring diagram showing a FireWire-B hub and two FireWire-B cameras. Most single camera systems will use the CFB-CBL- cable as shown in the diagram on the right, connecting the adapter and camera with no hub. The trigger and strobe I/O (CFB-IO-CBL-SCOUT or CFB-IO-CBL-BAS-V) provides access to trigger and strobe connections. All trigger and strobe lines are opto-isolated. Both cables have the same wire colors, as listed in the following table. Pin Wire Color Signal White NC Green NC Blue Input (Trigger) Red Input Grey Input Ground 6 Black Output (Strobe) 7 Purple Output 8 Brown NC 9 Yellow NC Pink Output Power Grey/Pink Output Red/Blue Output Input Source Input Output PWR Output FireWire 9B Adapter (CFB-IC-PCI) CFB-CBL- cable scout Camera I/O cable: CFB-IO-CBL-SCOUT (TTL/CMOS) CFB-IO-CBL-BAS-V (PLCs) Basler scout (FireWire) Trigger and Strobe See VisionPro or CVL documentation topics on FireWire acquisition. See the FireWire Cameras manual supplied with VisionPro. See the CCF (Camera Configuration File) for this camera for additional information. See the Cognex FireWire white paper available at: See the camera hardware manual: + VDC - + VDC Trigger Strobe

6 Network Interface Card (NIC) (CGE-NIC) The Basler scout and pilot GigE Vision cameras provide trigger and strobe support. The cameras provide general-purpose I/O lines, but these are not available through Cognex I/O programming interface. Refer to the camera documentation for information on using these lines. Basler V power supply Ethernet cable (CGE-CBL-/) Y-cable (CGE-IO-CBL-BAS-Y) You must use the Cognex GigE Vision Configuration Tool to configure these cameras before using them. Ethernet switch (CGE-SWITCH) I/O cable: CFB-IO-CBL-SCOUT (TTL/CMOS) CFB-IO-CBL-BAS-V (PLCs) The standard I/O cable (CGE-IO-CBL-BAS-M) is intended for use in lowvoltage TTL (V) and CMOS (.V) environments only. Use the V cable (CGE-IO-CBL-BAS-V) with V equipment such as PLCs and relays. Camera Camera power and ground are supplied through pins on the -pin Hirose connector. If you provide power through the flying lead cable, make sure to use all four leads to avoid excessive voltage drop. If you are using the Basler power supply, which is equipped with a Hirose connector, you must use the Y-cable (CGE-IO-CBL-BAS-Y) in addition to the I/O cable (CGE-IO-CBL-BAS-M or CGE-IO-CBL-BAS-V) to connect trigger and strobe lines. Both types of wiring are shown on the next page. Refer to the camera documentation for specific power requirements. Camera r we Po To connect GigE Vision cameras to your PC you must use a dedicated network interface card (NIC) that is separate from the NIC your PC uses for network traffic. A Cognex-supplied NIC (CGE-NIC-, CGE-NIC, or CGE-NIC-) is recommended. O DI The wiring diagram on the right shows how to use a network switch (CGE-SWITCH) to connect multiple cameras. You can use additional switches, bridges, and routers to connect more cameras. You can also use a multi-port NIC. This NIC must be separate from the NIC your PC uses for network traffic. Camera Camera PWR Input Input The trigger and strobe I/O (CGE-IO-CBL-BAS-M or CGE-IO-CBL-BAS-V) provides access to trigger and strobe connections as well as power. All trigger and strobe lines are opto-isolated. Both cables have the same wire colors, as listed in the following table. Source Pin Signal Camera Input Power Ground. Pins and are connected inside the camera. White Green Camera Input Power Ground. Pins and are connected inside the camera. Blue Input (+ to + VDC) (Trigger) Red Input (+ to + VDC) + I/O Input Ground I/O Output (Strobe) Output PWR Input - Grey Black VDC 6 Output Input + VDC Wire Color Basler scout and pilot (GigE Vision) Trigger and Strobe Basler scout and pilot (GigE Vision) Trigger and Strobe I/O Output Camera Input Power, + to + VDC. Pins 8 and 9 are connected inside the camera. 9 Yellow Camera Input Power, + to + VDC. Pins 8 and 9 are connected inside the camera. Pink I/O Output Power (+ to + VDC) Grey/Pink I/O Output Red/Blue I/O Output Source + + VDC - Purple Brown + VDC See VisionPro or CVL documentation topics on GigE Vision acquisition. See the GigE Vision manual supplied with VisionPro. See the camera hardware manual: Trigger Strobe

7 Basler ace (GigE Vision) Trigger and Strobe The Basler ace GigE Vision cameras provide trigger and strobe support. You must use the Cognex GigE Vision Configuration Tool to configure these cameras before using them. The standard I/O cable (CGE-IO-CBL-ACE-M) is intended for use in lowvoltage TTL (V) and CMOS (.V) environments only. Use the V cable (CGE-IO-CBL-ACE-V) with V equipment such as PLCs and relays. Camera power and ground may be supplied in two ways: through the RJ- Ethernet connector using the Power over Ethernet (PoE) standard or through pins and 6 on the 6-pin Hirose connector. If power is supplied through both sources, the camera will draw from the Hirose connector only. If you use the Basler power supply (CGE-PWR-ACE), you will not have access to the camera trigger and strobe lines. To connect GigE Vision cameras to your PC, you must use a dedicated network interface card (NIC) that is separate from the NIC your PC uses for network traffic. A Cognex-supplied NIC (CGE-NIC-, CGE-NIC, or CGE-NIC) is recommended. You can use a stand-alone PoE injector (CGE-POE-INJ-ACE) to provide power over the Ethernet connection, or you can use a PoE-enabled NIC (CGE-POE-NIC) to provide power to the camera. Alternately, you can use an integrated PoE injector/switch (CGE-POE-SWITCH8) to power multiple cameras over Ethernet. The wiring diagram on the right shows two externally powered cameras connected to a non- PoE network switch (CGE-SWITCH) as well as a third camera powered over Ethernet using a PoE injector (CGE-POE-INJ-ACE). Camera Network Interface Cards (NIC) (CGE-NIC) Basler power supply (CGE-PWR-ACE) Ethernet cable (CGE-CBL-/) Ethernet switch (CGE-SWITCH) V I/O (CGE-IO-CBL-ACE-V) PoE injector (CGE-POE-INJ-ACE) Standard I/O (CGE-IO-CBL-ACE-M) Camera Basler ace (GigE Vision) Trigger and Strobe The trigger and strobe I/O (CGE-IO-CBL-ACE-M or CGE-IO-CBL-ACE-V) provides access to trigger and strobe connections as well as power. All trigger and strobe lines are opto-isolated. Input I/O The lead colors for the standard (CGE-IO-CBL-ACE-M) and V (CGE-IO- CBL-ACE-V) cables are different. The table below lists the lead colors for both cables. Camera Source + Pin Wire Color Signal CGE-IO-CBL-ACE-M CGE-IO-CBL-ACE-V Brown Brown Camera Input Power (+ VDC) Input Camera I/O Output VDC Pink Green Input (+ to + VDC) (Trigger) Green Pink not connected Camera PWR Yellow Yellow Output Grey Grey I/O Ground 6 White White Camera Input Power Ground Source Consult your Basler camera documentation for changes to output line management between early production and later production versions of firmware. For more information, see your VisionPro or CVL documentation and your camera hardware manual at + VDC - + VDC - 7 Ω + Trigger Strobe

8 Basler runner (GigE Vision) Line Scan To connect a Basler runner GigE Vision line scan camera to an encoder or a TTL or optoisolated trigger, use the Basler I/O cable CGE--CBL-RNR-M,with the following pin assignments: Pin Wire Color Signal White I/O Input - Brown I/O Input + Green I/O Input - Yellow I/O Input + 8 Black I/O Input - 9 Violet I/O Input + I/O line assignments are programmable. You can control which I/O pair receive encoder signals and frame triggers. General Notes Cognex recommends the Basler I/O cable (CGE-IO-CBL-RNR-M) for connecting the camera to the encoder and trigger. Reduce the output voltage from the trigger source from V to V to avoid damaging the GigE Vision camera. You must configure the following parameters in order to use a Basler runner GigE Vision line scan camera: ROI parameters to define what will constitute a frame (9 maximum height); Acquisition properties such as TriggerSelector, TriggerMode, and TriggerActivation; I/O properties such as line debounce and termination; While it is possible to perform the camera configuration using CVL or VisionPro, Cognex recommends using the Basler pylon Viewer standalone application supplied with the camera. For more information, see the Basler User s Manual for GigE Vision cameras at: In addition, see the application note here: To set the IP address of the GigE Vision network adapter and GigE Vision camera, use the GigE Vision Configuration Tool, installed with your CVL or VisionPro software. I/O - I/O + I/O - I/O + I/O + A A B B Network Interface Card (NIC) (CGE-NIC) Ethernet cable (CGE-CBL-/) Basler runner GigE Vision Line Scan camera Basler power supply Basler I/O (CGE-IO-CBL-RNR-M) Voltage reduced to V Basler runner (GigE Vision) Line Scan Source - Trigger + VDC - RS Encoder

9 General-Purpose Digital I/O (PCI Bus Adapter) Note: Only supported for VisionPro. The CIO-PCI-PS general-purpose digital I/O kit provides bidirectional I/O lines, configurable using opto-isolated wiring. This kit can be used with any Cognex hardware, GigE Vision cameras, FireWire cameras, or third-party image acquisition devices. The kit includes: A PCI bus adapter card for your PC A m cable An external circuit board providing wiring terminals and supporting standard solid-state relays (SSRs) for opto-isolation. The 8-line version of the I/O module, CIO-PCI-P8S, also includes a DIN rail mounting kit (7-7). The board s lines are divided into four banks: lines -7, 8-, 6-9, and -. All lines within a bank must be configured as input or output lines. The kit is not supplied with solid-state relays. They can be obtained from numerous vendors. Signal Names The lines are referred to in software as lines -, corresponding to the line numbers on the module. In the Communications Explorer, the lines are shown as Bidirectional -. Note: If you are using the 8-line version of the I/O module, CIO-PCI- P8S, then the 8 lines on the I/O module correspond to lines 6- in the Communications Explorer. See topics on I/O line numbering and Communications Explorer in VisionPro online documentation. See the Measurement Computing Hardware Manuals: VDC - CIO-PCI-PS: PCI Interface card (7-6) (8-9) I/O module (7-6) User-supplied: Solid-state relay General-Purpose Digital I/O (PCI Bus Adapter) DC OUT DC IN DC OIN DC OUT 6 7 PLC In PLC Out Stack Light

10 General-Purpose Digital I/O (USB Adapter) Note: Only supported for VisionPro. The CIO-USB-PS Measurement Computing LS/USB device provides bidirectional TTL lines. The device provides V output and ground lines that you can use to perform contact-closure wiring. The device does not provide opto-isolation. The lines are divided into four banks: lines -7, 8-, 6-9, and -. All lines within a bank must be configured as input or output lines. Signal Names Pin assignments are listed below. Pin refers to the number printed on the device, Signal is the signal name used in the Measurement Computing documentation, and Comm. Explorer Name is the name to select in the VisionPro QuickBuild interface: Pins - Pins - Pin Signal Comm. Explorer Name Pin Signal Comm. Explorer Name C Bidirectional 6 A Bidirectional C Bidirectional 7 A Bidirectional C Bidirectional 8 A Bidirectional C Bidirectional 9 A Bidirectional C Bidirectional A Bidirectional 6 C Bidirectional 6 A Bidirectional 7 C6 Bidirectional 7 A6 Bidirectional 6 8 C7 Bidirectional 8 A7 Bidirectional N/C +V N/C B Bidirectional 8 N/C B Bidirectional 9 N/C B Bidirectional B Bidirectional 6 N/C 6 B Bidirectional 7 7 B Bidirectional 8 N/C 8 B6 Bidirectional 9 9 B7 Bidirectional CTR TRUE CIO-USB-PS: I/O module (-R) Two-meter USB cable General-Purpose Digital I/O (USB Adapter) See topics on I/O line numbering and Communications Explorer in VisionPro online documentation. See the Measurement Computing Hardware Manual: FALSE Contact closure input 8 9

11 MVS-8 Opto-Isolated Wiring The MVS-8 provides opto-isolated connections for trigger inputs, strobe outputs, and general-purpose inputs and outputs using the IO-OPTO-8 kit, which comprises an I/O module (8-7-R) and cable (-89-R). Physical line state of Opto I/O module output lines is inverted from other modules. Logical true means no current flow; logical false means current flow. Opto I/O module provides no power for input or output devices. All lines are polarity independent and can be connected to sinking or sourcing devices. Keep in mind that you must specify, in software, which I/O configuration you are using. Signal Names The following table maps module lines to VisionPro software lines and Communications Explorer line names. Inputs Outputs Label Software Line Comm. Explorer Name Label Software Line Comm. Explorer Name IN Input OUT Output IN Input OUT Output IN Input OUT 6 Output 6 INPUTS TO MVS-8 IO-OPTO-8: (-89-R) I/O module (8-7-R) OUTPUTS FROM MVS-8 Opto-Isolated Wiring IN Input OUT 7 Output 7 IN 8 T Input 8 OUT 9 S Output 9 IN T Input OUT S Output IN6 T Input OUT6 S Output IN IN IN IN IN IN IN 6 IN 7 GROUND OUT OUT OUT OUT OUT OUT OUT 6 OUT 7 IN7 T Input OUT7 S Output Lines IN-IN7 reserved as triggers for Camera -; Lines OUT-OUT7 reserved as strobes for cameras -. See MVS-8 Hardware Manual. See topics on I/O line numbering and Communications Explorer in VisionPro online documentation. + VDC - + VDC - Source + DC OUT DC IN Trigger PLC In Strobe

12 MVS-8 TTL Wiring The MVS-8 provides TTL-level connections for triggers, strobes, and bidirectional I/O lines through the MDR- connector on the faceplate. Cognex recommends the use of the TTL I/O Kit (IO-TTL-8), which provides an I/O module and extension cable. The lines designated as trigger and strobe lines can also be used for general-purpose I/O. To use them as triggers and strobes, they must be disabled as input or output lines. Signal Names The following table maps module lines to VisionPro software lines and Communications Explorer line names. The Label name refers to the printed label on the I/O module. Label Software Line Comm. Explorer Name Label Software Line Comm. Explorer Name T 8 TRIGGER B Bidirectional S 9 STROBE B Bidirectional T TRIGGER B Bidirectional MVS-8 IO-TTL-8: (-9-R) I/O module (8-88-) MVS-8 TTL Wiring S STROBE B Bidirectional T TRIGGER B Bidirectional S STROBE B Bidirectional T TRIGGER B6 6 Bidirectional 6 S STROBE B7 7 Bidirectional 7 Pins labeled G are ground; pins labeled NC are not connected. B B B B B B B6 B7 G NC NC NC NC T S T S T S T S G NC NC NC NC PN Combined (Split) TTL and Opto-Isolated Wiring The IO-OPTO-TTL-8 kit provides a combination of TTL and Opto-isolated wiring. This kit is described in detail in the MVS-8 Hardware Manual. TTL wiring and the TTL I/O module are described in detail in the MVS-8 Hardware Manual. See topics on I/O line numbering and Communications Explorer in VisionPro online documentation. + VDC - Source + Trigger Strobe (TTL Controller)

13 MVS-86 Opto-Isolated Trigger and Strobe (Area Scan) Both TTL and Opto-Isolated trigger and strobe wiring are supported through the CIO-86- LVDS and CIO-86-TTL I/O module kits. If you are using an area scan camera, then you can use either CIO-86-LVDS or CIO-86- TTL; the only difference between these kits is which type of encoder they support. Keep in mind that you must specify, in software, which I/O configuration you are using. The I/O module provides both +V and +V power for TTL and Opto-Isolated devices. This power is supplied by the MVS-86 through the Hirose connector. The I/O module provides separate labeled connections for TTL strobe outputs ( and ), TTL trigger inputs ( and ), Opto-isolated strobe outputs ( and ), and Opto-isolated trigger outputs ( and ). Each connection point is clearly labeled on the I/O module. See the MVS-86 Hardware Manual. + VDC +V +V POWER OUTPUT +V POWER OUTPUT +V S+ OPTO T+ TTL TTL OPTO S T S T STRB/TRIG STRB/TRIG A/B A/B A/B A/B A B A B MVS-86 CIO-86-TTL or CIO-86-LVDS: (-9-R for LVDS; - -R for TTL) I/O module (8-88-R) S T S+ S- T+ T- S+ S- T+ B- STROBE TRIGGER O STROBE TRIGGER A+ A- B+ B- A+ A- B+ B- TTL I/O LVDS LVDS CHASSIS J MVS-86 Opto-Isolated Trigger and Strobe (Area Scan) Sink + Trigger Strobe

14 MVS-86 TTL Trigger and Strobe (Area Scan) Both TTL and Opto-Isolated trigger and strobe wiring are supported through the CIO-86- LVDS and CIO-86-TTL I/O module kits. If you are using an area scan camera, then you can use either CIO-86-LVDS or CIO-86- TTL; the only difference between these kits is which type of encoder interface (TTL or LVDS) they support. Keep in mind that you must specify, in software, which I/O configuration you are using. The I/O module provides both +V and +V power for TTL and Opto-Isolated devices. This power is supplied by the MVS-86 through the Hirose connector. The I/O module provides separate labeled connections for TTL strobe outputs ( and ), TTL trigger inputs ( and ), Opto-isolated strobe outputs ( and ), and Opto-isolated trigger outputs ( and ). Each connection point is clearly labeled on the I/O module. See the MVS-86 Hardware Manual. +V +V POWER OUTPUT +V POWER OUTPUT + VDC +V S TTL TTL OPTO OPTO T S T S T STRB/TRIG STRB/TRIG A/B A/B A/B A/B A B A B MVS-86 CIO-86-TTL or CIO-86-LVDS: (-9-R for LVDS; - -R for TTL) I/O module (8-88-R) S+ S- T+ T- S+ S- T+ B- STROBE TRIGGER O STROBE TRIGGER A+ A- B+ B- A+ A- B+ B- TTL I/O LVDS LVDS CHASSIS J MVS-86 TTL Trigger and Strobe (Area Scan) Source + Trigger Strobe (TTL Controller) 6 7

15 MVS-86 Opto-Isolated General-Purpose I/O On the MVS-86, opto-isolated programmable I/O is supported through the CIO-86-GPIO kit. Adjacent pairs of input lines share a common V pin, so if you want to use all the lines, you must wire the MVS-86 as a current sink. In addition to the general-purpose I/O lines, this module also provides access to TTL-level trigger and strobe connections. If you are using the Dual-LVDS configuration, you must use these lines to trigger your cameras, but for other configurations Cognex recommends that you use the appropriate I/O module for access to these lines. The I/O module also provides access to supplemental camera power outputs and both TTL and LVDS encoder inputs. Cognex recommends not using the camera power outputs and using the appropriate I/O module for encoder connections (those connections are shown in blue in the table). Signal Names The following table maps module lines to VisionPro software lines and Communications Explorer line names. The Label name refers to the printed label on the I/O module. Label P/P6 Pin P Block Signal P6 Block Signal OUTPUT + OUTPUT + OUTPUT - OUTPUT - INPUT & + INPUT & + 7 INPUT - INPUT - 9 INPUT - INPUT - 6 ENCODER A+ (8-88-R) STROBE / ENCODER A+ (8-88-R) 7 ENCODER A- (8-88-R) STROBE / ENCODER A- (8-88-R) 8 CAMERA POWER V (NR) CAMERA POWER V (NR) + OUTPUT G P P + INPUT - + OUTPUT - MVS-86 CIO-86-GPIO: Two ribbon cables and faceplate panels (--R) Two DBM cables (8-) Two I/O modules (9-) G P P + OUTPUT - MVS-86 Opto-Isolated General-Purpose I/O 9 7 OUTPUT + OUTPUT OUTPUT - OUTPUT VDC - INPUT & + INPUT 6 & 7 + INPUT - INPUT 6 - INPUT - INPUT 7 - V INPUT FOR OUTPUT LINES - V FOR OUTPUT LINES -7 OUTPUT + OUTPUT OUTPUT - OUTPUT GROUND GROUND 8 CAMERA POWER V (NR) CAMERA POWER V (NR) 9 GROUND GROUND DC IN DC OUT N/C N/C 6 GROUND GROUND 8 OUTPUT + OUTPUT 7 + DC OUT DC OIN OUTPUT - OUTPUT 7 - ENCODER B+ (8-88-R) TRIGGER /ENCODER B+ (8-88-R) ENCODER B- (8-88-R) TRIGGER /ENCODER B- (8-88-R) See the MVS-86 Hardware Manual. PLC Input PLC Output Stack light 8 9

16 MVS-86 Single LVDS Encoder (Line Scan) To connect a single LVDS encoder for use with one or two line scan cameras, use the CIO- 86-LVDS I/O kit. This configuration lets you connect trigger inputs, strobe outputs, and LVDS encoder inputs for a single line scan camera, one line scan and one area scan camera, or two line scan cameras sharing a single LVDS encoder. The MVS-86 clamps encoder inputs to +V. Cognex recommends that you use encoders that output no more than +VDC. Both TTL and opto-isolated trigger and strobe connections are supported. Keep in mind that you must specify, in software, which I/O configuration you are using. See MVS-86 Hardware Manual. See the Cognex Line Scan Acquisition White Paper available at: See the Cognex Technical Bulletin on Selecting Encoders available at: See topics on I/O line numbering and Communications Explorer in VisionPro online documentation. + VDC +V +V POWER OUTPUT +V POWER OUTPUT +V + VDC TTL TTL OPTO OPTO S T S T STRB/TRIG STRB/TRIG MVS-86 CIO-86-LVDS: (-9-R) I/O module (8-88-R) T+ T S+ S- T+ T- S+ S- T+ B- STROBE TRIGGER O STROBE TRIGGER A/B A/B A/B A/B A B A- B+ A- B A A+ B- A+ B+ B- TTL I/O LVDS LVDS CHASSIS J MVS-86 Single LVDS Encoder (Line Scan) A B DC A B Sink Trigger (opto) LVDS Encoder

17 MVS-86 Dual LVDS Encoder (Line Scan) To connect dual LVDS encoders for use with a line scan camera, use the CIO-86-DLVDS I/O kit. This configuration lets you connect LVDS encoder inputs from two LVDS encoders. Unlike the single LVDS or single/dual TTL configurations, the dual LVDS configuration does not allow you to connect any trigger inputs or strobe outputs directly to the I/O module. Instead, use the CIO-86-DLVDS-TRG kit to connect a trigger input or inputs (opto-isolated only). The MVS-86 clamps encoder inputs to +V. Cognex recommends that you use encoders that output no more than +VDC. In addition to providing for trigger inputs, the CIO-86-GPIO kit also provides full access to the general-purpose programmable input and output lines. Keep in mind that you must specify, in software, which I/O configuration you are using. See MVS-86 Hardware Manual. See the Cognex Line Scan Acquisition White Paper available at: See the Cognex Technical Bulletin on Selecting Encoders available at: See topics on I/O line numbering and Communications Explorer in VisionPro online documentation. P Connector Only +V +V POWER OUTPUT +V POWER OUTPUT +V + VDC TTL TTL OPTO OPTO S T S T STRB/TRIG STRB/TRIG A/B A/B A/B A/B A B A B S+ S- T+ T- S+ S- T+ B- STROBE TRIGGER O STROBE TRIGGER A+ A- B+ B- A+ A- B+ B- TTL I/O LVDS LVDS A B DC A B A CHASSIS J MVS-86 CIO-86-DLVDS: Ribbon cable and faceplate (--R) (-8-) I/O module (8-88-R) CIO-86-DLVDS-TRG: DBM cable (8-) I/O module (9-) B A B P G P TRIGGER TRIGGER GROUND MVS-86 Dual LVDS Encoder (Line Scan) Sink Sink Encoder (LVDS) Encoder (LVDS) Trigger (Opto) Trigger (Opto)

18 MVS-86 Single/Dual TTL Encoder (Line Scan) To connect a single or dual TTL encoder for use with a line scan camera or cameras, use the CIO-86-TTL I/O kit. This configuration lets you connect TTL encoder inputs from two TTL encoders. You can also connect TTL or opto-isolated trigger inputs for or line scan cameras. Both TTL and opto-isolated trigger and strobe connections are supported. Keep in mind that you must specify, in software, which I/O configuration you are using. See MVS-86 Hardware Manual. See the Cognex Line Scan Acquisition White Paper available at: See topics on I/O line numbering and Communications Explorer in VisionPro online documentation. +V TTL TTL OPTO OPTO T T S T S T S+ S- T+ T- S+ S- T+ B- +V POWER OUTPUT STRB/TRIG STRB/TRIG STROBE TRIGGER O STROBE TRIGGER +V POWER OUTPUT A/B A/B A/B A/B +V A B A B A+ A- B+ B- A+ A- B+ B- TTL I/O LVDS LVDS CHASSIS J A A MVS-86 CIO-86-TTL: (--R) I/O module (8-88-R) MVS-86 Single/Dual TTL Encoder (Line Scan) B B DC Source Source Encoder (TTL) Encoder (TTL) Trigger (TTL) Trigger (TTL)

19 9-76

0.25m long cable directly out of the sensor. Blue laser line (405nm) for (semi-) transparent, red-hot glowing and organic materials

0.25m long cable directly out of the sensor. Blue laser line (405nm) for (semi-) transparent, red-hot glowing and organic materials Options, cables and accessories scancontrol 2x0/29x0 Options*: /SI Integrated sensor ON/OFF /PT Pigtail cable Hardware ON/OFF of the laser line 0.2m long cable directly out of the sensor /3B Class 3B /BL

More information

Connecting a Cisco Reader Module

Connecting a Cisco Reader Module CHAPTER 3 Overview The optional Cisco Reader Module (Figure 3-1) is similar to the Cisco Physical Access Gateway, providing the same ports for Weigand readers and other input and output devices. The Cisco

More information

HAWK MV-4000 Smart Camera

HAWK MV-4000 Smart Camera HAWK MV-4000 Smart Camera Configuration Guide Hardware Required Item Description Part Number HAWK MV-4000 Smart Camera 8XX-XXX0-00X Lens, C-Mount 98-9000XX-0 3 IP67 Lens Cover for HAWK MV-4000, 50 mm or

More information

EPGG001. Fieldbus Gateway RS-232 to PROFINET. Industrial Communication. Technical Data. Part Number

EPGG001. Fieldbus Gateway RS-232 to PROFINET. Industrial Communication. Technical Data. Part Number Fieldbus Gateway RS-232 to PROFINET EPGG001 Part Number Easy handling Gateway from RS-232/422/485 interfaces to PROFINET With two Industrial Ethernet ports Technical Data Electrical Data Supply Voltage

More information

In-Sight 7010C/7200C/7400C

In-Sight 7010C/7200C/7400C The following sections list general specifications for the In-Sight vision system. Vision System Specifications Table 3-1: Vision System Specifications Specifications Minimum Firmware Requirement Job/Program

More information

Automation Interface Requirements for System I/O Interface of a DPC I Welding System

Automation Interface Requirements for System I/O Interface of a DPC I Welding System - 1 - Automation Interface Requirements for System I/O Interface of a DPC I Welding System The DPC I welding system offer several features that are intended to communicate with automation. These features

More information

128MB non-volatile flash memory; unlimited storage via remote network device.

128MB non-volatile flash memory; unlimited storage via remote network device. The following sections list general specifications for the In-Sight Micro vision systems. In-Sight Micro Vision System Specifications Table 3-1: In-Sight Micro Vision System Specifications Specifications

More information

I/O Expansion Module Installation & Reference

I/O Expansion Module Installation & Reference Overview The In-Sight vision sensor supports up to ten discrete inputs and ten discrete outputs. Two inputs and two outputs are built-in to the In-Sight processor. The remaining eight inputs and outputs

More information

Communication Card. Installation Manual

Communication Card. Installation Manual Communication Card Installation Manual Legal Notices The software described in this document is furnished under license, and may be used or copied only in accordance with the terms of such license and

More information

IB080QM65VA3 Part Number

IB080QM65VA3 Part Number Inductive Proximity Switch with increased Switching Distance IB080QM65VA3 Part Number Technical Data Inductive Data Switching Distance 8 mm Correction Factors V2A/CuZn/Al 0,93/0,40/0,36 quasi-flush A/B/C/D

More information

Trigger I/O Board for the LogiComm Gun Driver

Trigger I/O Board for the LogiComm Gun Driver Instruction Sheet Trigger I/O Board for the LogiComm Gun Driver P/N 1084488A WARNING: This trigger I/O board is not directly compatible with the previous versions (P/N s 1069804 and 1069805). Refer to

More information

FEATURES. APPLICATIONS Machine Vision Embedded Instrumentation Motion Control Traffic Monitoring Security

FEATURES. APPLICATIONS Machine Vision Embedded Instrumentation Motion Control Traffic Monitoring Security FEATURES High-performance CMOSIS sensors - Sensitivity: 5.56 V/lux.s - Dynamic range: 60 db - Dark Noise: 8.6 e - - High speed: 95* fps - 8M Pixel: 3360(H) x 2496(V) - Monochrome / Color - Global Shutter

More information

Micro automation platform

Micro automation platform pages / to / pages / and / pages / to / Connection principles Connecting modules with screw terminal blocks The screw connection terminal blocks are fitted with a removable cover ensuring : i The screws

More information

Basler. CMOSIS models with Camera Link and up to 340 fps

Basler. CMOSIS models with Camera Link and up to 340 fps Basler Area Scan Cameras CMOSIS models with Camera Link and up to 340 fps Ground-breaking price starting at 299 euros Gigabit Ethernet interface with PoE Camera Link interface for high throughput with

More information

AG300 Family CTL01-3A-03, AMP01-2A-02

AG300 Family CTL01-3A-03, AMP01-2A-02 AG300 Family CTL01-3A-03, AMP01-2A-02 Hardware User's Manual Page 1 Revision control table Version Description Date 1.0 Initial (based on Hardware Manual of previous hardware versions) April 27, 2016 1.1

More information

Prosilica GT. Description. 5.1 Megapixel machine vision camera with Sony IMX CMOS sensor. Benefits and features:

Prosilica GT. Description. 5.1 Megapixel machine vision camera with Sony IMX CMOS sensor. Benefits and features: Prosilica GT 2460 Versatile temperature range for extreme environments IEEE 1588 PTP Power over Ethernet P-Iris and DC-Iris lens control Description 5.1 Megapixel machine vision camera with Sony IMX CMOS

More information

Basler Accessories. Technical Specification POWER-I/O-PLC+ CABLE, HRS 12P/OPEN, 10M. Order Numbers

Basler Accessories. Technical Specification POWER-I/O-PLC+ CABLE, HRS 12P/OPEN, 10M. Order Numbers DRAFT Basler Accessories Technical Specification POWER-I/O-PLC+ CABLE, HRS 12P/OPEN, 10M Order Numbers 2000034085 Document Number: DG001399 Version: 01 Language: 000 (English) Release Date: 22 September

More information

Cognex MVS-8000 Series. MVS-8600 and MVS-8600e Hardware Manual

Cognex MVS-8000 Series. MVS-8600 and MVS-8600e Hardware Manual Cognex MVS-8000 Series MVS-8600 and MVS-8600e Hardware Manual August 2007 The software described in this document is furnished under license, and may be used or copied only in accordance with the terms

More information

Saab TransponderTech. INSTALLATION GUIDE J4N Junction Box for R4 Navigation System

Saab TransponderTech. INSTALLATION GUIDE J4N Junction Box for R4 Navigation System Saab TransponderTech INSTALLATION GUIDE J4N Junction Box for R4 Navigation System Page i i Copyright The entire contents of this manual and its appendices, including any future updates and modifications,

More information

The DVT Ethernet IO Module (CON-IOE)

The DVT Ethernet IO Module (CON-IOE) The DVT Ethernet IO Module (CON-IOE) Revision 4 (11/11/04) DVT Corporation DVT Corporation Installation of DVT Ethernet IO Module (CON-IOE) Hardware Mechanical Installation: The CON-IOE is designed to

More information

In-Sight. Micro Series I/O Module Installation Manual

In-Sight. Micro Series I/O Module Installation Manual In-Sight Micro Series I/O Module Installation Manual Legal Notices The software described in this document is furnished under license, and may be used or copied only in accordance with the terms of such

More information

In-Sight 7000 Series Vision System FAQs

In-Sight 7000 Series Vision System FAQs In-Sight 7000 Series Vision System FAQs Contents Imager... 4 Q: What is the imager size?... 4 Q: Since the imager is CMOS, how is the image quality of the In-Sight 7000 image sensor?... 4 Q: How is the

More information

POWERWISE INDAC SETUP MANUAL

POWERWISE INDAC SETUP MANUAL POWERWISE INDAC SETUP MANUAL REVISION: 2.2 INDAC & EMONITOR GATEWAY An installation guide for the PowerWise indac. 2013 PowerWise, Inc. This manual may contain proprietary information about the product

More information

Hardware User s Manual. Digital Video Motion Detector DVMD1-X

Hardware User s Manual. Digital Video Motion Detector DVMD1-X Hardware User s Manual Digital Video Motion Detector DVMD1-X Version 010 Revision A July, 2004 2395 Kenwood Drive Boulder, CO 80303 (303) 543-0440 TECHNICAL SPECIFICATIONS VENDOR Radiant Inc. http://www.dvmd.com

More information

YM24PAH2ABF. Contrast Sensor. LASER Technical Data. Photoelectronic Sensors. Part Number

YM24PAH2ABF. Contrast Sensor. LASER Technical Data. Photoelectronic Sensors. Part Number Contrast Sensor YM24PAH2ABF Part Number High switching frequency Small light spot Time delay can be activated LASER Technical Data Optical Data Range 150 mm Adjustable Range 60...150 mm Switching Hysteresis

More information

Y800 Plus Frequency, Rate & Period Meter With dual, independently field-scalable channels

Y800 Plus Frequency, Rate & Period Meter With dual, independently field-scalable channels Y800 Plus Frequency, Rate & Period Meter With dual, independently field-scalable channels Description Features Frequencies from 0.005 Hz to 1 MHz 6-digit resolution at update rates up to 25/s Selectable

More information

Engineering Guideline. pac-carriers Type for Honeywell system Experion Series C I/O

Engineering Guideline. pac-carriers Type for Honeywell system Experion Series C I/O Engineering Guideline pac-carriers Type 995 for Honeywell system Experion Series C I/O pac-carrier Type 995 Engineering Guideline/Honeywell 04..009 pac-carrier Type 995 Integration of conventional process

More information

4 Connection and interface

4 Connection and interface MDrive 23 Motion Control 4 Connection and Interface 4 Connection and interface EXPOSED SIGNALS! DANGER Hazardous voltage levels may be present if using an open frame power supply to power the product.

More information

VISION SENSORS VISION SENSORS. Fully embedded vision sensor 3.5 VSC configurator 7 different controls Memorisation of 8 inspections

VISION SENSORS VISION SENSORS. Fully embedded vision sensor 3.5 VSC configurator 7 different controls Memorisation of 8 inspections VISION SENSORS VISION SENSORS Fully embedded vision sensor 3.5 VSC configurator 7 different controls Memorisation of 8 inspections The SVS1 series is the easiest solution for machine vision applications.

More information

GSV-1A4 M12/2 M12/2. Highlights

GSV-1A4 M12/2 M12/2. Highlights GSV-1A4 M12/2 M12/2 Highlights Input sensitivity: 2mV/V; 4mV/V, 2 mv/v, 1mV/V, 0.5mV/V configurable via jumpers Output signals ±10V AND 12mA+-8mA on 15 pin Sub-D Integrated half and quarter bridge completion

More information

Prosilica GT. Description. 5.1 Megapixel CMOS camera for outdoor imaging - GigE Vision. Benefits and features: Options:

Prosilica GT. Description. 5.1 Megapixel CMOS camera for outdoor imaging - GigE Vision. Benefits and features: Options: Prosilica GT 2460 Versatile temperature range for extreme environments IEEE 1588 PTP Power over Ethernet P-Iris and DC-Iris lens control Description 5.1 Megapixel CMOS camera for outdoor imaging - GigE

More information

FVT/FVR20D2I1C4E INSTALLATION AND OPERATION MANUAL

FVT/FVR20D2I1C4E INSTALLATION AND OPERATION MANUAL 2-CHANNEL 10-BIT DIGITALLY ENCODED VIDEO + 2 BI-DIRECTIONAL DATA + AIPHONE INTERCOM + 4 CONTACT CLOSURE + 100MB ETHERNET + REDUNDANT POINT-TO-POINT DUAL SFP OPTICAL PORTS The series utilize 10-bit digital

More information

USB DIO High Voltage and Relay

USB DIO High Voltage and Relay DIO High Voltage and -PDISO, -ERB, and - Series -PDISO Series -ERB Series - Series Overview Measurement Computing DIO high voltage and relay product offerings include the -PDISO Series, -ERB Series, and

More information

Analog Input and Output Options for Syringe Pumps

Analog Input and Output Options for Syringe Pumps Analog Input and Output Options for Syringe Pumps Installation and Operation Instructions Syringe Pumps Technical Bulletin TB03 Overview Teledyne Isco offers several options for external analog control

More information

USBIO24 RL Digital I/O Module

USBIO24 RL Digital I/O Module Ether I/O 24 Digital I/O Module The Ether I/O 24 is an UDP/IP controlled digital Input/Output module. The module features three 8-bit ports with 5V level signal lines. Each of the 24 lines can be independently

More information

Defining the Future in Motion Control

Defining the Future in Motion Control Defining the Future in Motion Control USER S MANUAL 1 DINIO7 user s manual Overview The DINIO7 is a DIN-rail mounted peripheral for the SmartMotor versions 3 and 4 product lines Hereafter, the SmartMotor

More information

Driver/Controller Development Assistance Package For IDEX Health & Science TitanHT TM Driver Board

Driver/Controller Development Assistance Package For IDEX Health & Science TitanHT TM Driver Board Driver/Controller Development Assistance Package For IDEX Health & Science TitanHT TM Driver Board Page 1 of 19 Table of Contents Proprietary Letter... 3 Introduction... 4 Section 1.0 Driver Specifications

More information

INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx

INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual PCMNET V 7. xx INTEGRATED SYSTEMS AND CONTROLS, INC. PCMNET Users Manual Revised 2/4/2005 2003-2005 Integrated Systems and Control. Inc. PO Box

More information

GigE Vision camera featuring the Sony IMX273 CMOS sensor

GigE Vision camera featuring the Sony IMX273 CMOS sensor Manta G-158 Sony IMX273 CMOS sensor Power over Ethernet option Angled head and board level variants Video-iris lens control Description GigE Vision camera featuring the Sony IMX273 CMOS sensor Manta G-158

More information

the Interactive Catalog

the Interactive Catalog Interactive Catalog Supplements Catalog PDFs If you need detailed product information, or help choosing the right product for your application, see our Interactive Catalog Use the Interactive Catalog to

More information

User s Manual Hub444. Motion Control Network Hub

User s Manual Hub444. Motion Control Network Hub 8/23/02 JK User s Manual Motion Control Network Hub Applied Motion Products, Inc. 404 Westridge Drive Watsonville, CA 95076 Tel (831) 761-6555 (800) 525-1609 Fax (831) 761-6544 motors drives controls -2-

More information

The INJ-102GT-24V PoE Injector is an advanced IEEE802.3at compliant device with intelligent detection that provided

The INJ-102GT-24V PoE Injector is an advanced IEEE802.3at compliant device with intelligent detection that provided Industrial 2-port Gigabit High Power PoE Injector, 24V~50V Input Support Features Supports 2x10/100/1000Base-T(X) for power and data Output Fully compliant with IEEE802.3at/802.3af standard Auto protection

More information

lumentouch SPECIFICATION SHEET Client: Project name: Order #: Type: Qty: FEATURES AND BENEFITS PACKAGE CONTENT HOW TO ORDER LTO

lumentouch SPECIFICATION SHEET Client: Project name: Order #: Type: Qty: FEATURES AND BENEFITS PACKAGE CONTENT HOW TO ORDER LTO Client: Project name: Order #: Type: Qty: FEATURES AND BENEFITS Flat wall mounted lighting controller Universal mounting plate compatible with any electrical backbox MINI-USB connection for software programming

More information

PT2060 Monitor. PT2060/91 SIM System Interface Module. Specifications. Electrical. Messtechnik

PT2060 Monitor. PT2060/91 SIM System Interface Module. Specifications. Electrical. Messtechnik PT2060/ System Interface Module ProvibTech s PT2060/ module is a communication and system interface module. This module is used to: module. The two phase reference channels can be used to provide phase

More information

MicroHAWK ID-20 / ID-30 / ID-40

MicroHAWK ID-20 / ID-30 / ID-40 MicroHAWK ID-20 / ID-30 / ID-40 Configuration Guide Hardware Required Item Description Part Number MicroHAWK ID-20, MicroHAWK ID-30, or MicroHAWK ID-40 7ABX-YZZZ-LPPP 2, USB A to Micro B, 6 ft., ID-20

More information

USB1. Encoder Data Acquisition USB Device Page 1 of 6. Description. Features

USB1. Encoder Data Acquisition USB Device Page 1 of 6. Description. Features Description USB1 Page 1 of 6 The USB1 is no longer available for purchase, and has been replaced by our recently released USB4. The USB4 is a redesigned, enhanced version of the USB1, and is already available

More information

More Precision. colorsensor // Colour Sensors, LED Analyzers

More Precision. colorsensor // Colour Sensors, LED Analyzers More Precision colorsensor // Colour Sensors, LED Analyzers 32 Sensor systems for LED testing colorcontrol MFA - Multiple-point colour testing system - Optionally with up to 20 channels - Colour testing

More information

SMARTSCAN INFORMATION

SMARTSCAN INFORMATION SMARTSCAN INFORMATION RY4 SERIES SAFETY RELAYS HANDBOOK Smartscan Ltd, Pywell Road, CORBY, NN17 5XJ, UK, Tel: +44 (0) 1536 401313, Fax: +44 (0) 1536 268954, Email: sales@smartscan.com, www.smartscan.co.uk

More information

Introduction to Class 5 Connectivity

Introduction to Class 5 Connectivity Introduction to Class Connectivity APPENDIX SOFTWARE GEAR HEADS POWER SUPPLIES & SHUNTS IP MODELS & CONNECTIVITY PERIPHERALS CONNECTIVITY LINEAR SYSTEMS MOTOR SPECIFICATIONS OVERVIEW Power: Each SmartMotor

More information

Specifications minilab 1008

Specifications minilab 1008 Specifications minilab 1008 Document Revision 1.3, May, 2004 Copyright 2004, Measurement Computing Corporation Specifications Typical for 25 C unless otherwise specified. Analog Input Section A/D converter

More information

48-Bit Isolated Digital I/O

48-Bit Isolated Digital I/O 48-Bit Isolated Digital I/O NI 6527 24 optically isolated digital inputs (0-28 VDC) 24 isolated, solid-state relay digital outputs (0-60 VDC, 0-30 V rms ) Switch up to 120 ma Digital filtering on inputs

More information

GigE Vision camera featuring the Sony IMX287 CMOS sensor

GigE Vision camera featuring the Sony IMX287 CMOS sensor Manta G-040 Sony IMX287 CMOS sensor Power over Ethernet option Angled head and board level variants Video-iris lens control Description GigE Vision camera featuring the Sony IMX287 CMOS sensor Manta G-040

More information

Cognex MVS-8000 Series

Cognex MVS-8000 Series Cognex MVS-8000 Series MVS-8120 Hardware Manual October 2006 Distribué par : 2 rue René Laennec 51500 Taissy France Fax: 03 26 85 19 08, Tel : 03 26 82 49 29 Email : hvssystem@hvssystem.com Site web :

More information

4.8 Expansion Module MAC00-FS1/FS4

4.8 Expansion Module MAC00-FS1/FS4 .8 Expansion Module MAC00-FS/FS MAC00-FS With M connectors MAC00-FS With D sub connectors TT08GB.8. High speed serial RS8 module MAC00-FS and FS Introduction The MAC00-FS and FS are used for high speed

More information

Basler. CMOSIS models with Camera Link and up to 340 fps

Basler. CMOSIS models with Camera Link and up to 340 fps Basler Area Scan Cameras CMOSIS models with Camera Link and up to 340 fps Ground-breaking price starting at 299 euros Gigabit Ethernet interface with PoE Camera Link interface for high throughput with

More information

MDK. Accelnet Module DevKit. Provides Mounting & Connections for Accelnet CANopen Servoamplifiers FEATURES

MDK. Accelnet Module DevKit. Provides Mounting & Connections for Accelnet CANopen Servoamplifiers FEATURES Provides Mounting & Connections for Accelnet CANopen Servoamplifiers FEATURES Works with all Accelnet Models Develop & Debug Accelnet projects then transfer design to oem pc board. Dev Kit Model * Vdc

More information

LAUREL. Laureate Dual-Channel Pulse Input Totalizer With Two Independently Scalable Input Channels & Presets ELECTRONICS, INC. Features.

LAUREL. Laureate Dual-Channel Pulse Input Totalizer With Two Independently Scalable Input Channels & Presets ELECTRONICS, INC. Features. Description LAUREL ELECTRONICS, INC. Laureate Dual-Channel Pulse Input Totalizer With Two Independently Scalable Input Channels & Presets Features Frequencies up to 1 MHz Totals stored in non-volatile

More information

HI SEC Integrated Systems

HI SEC Integrated Systems Service Note 145 HI SEC Integrated Systems Subject: New S-ART 2xx Range Ref. No.: 93014501 Service Note 145 Summary: This Service Note describes a new enhanced range of S-ART s which will replace the existing

More information

Checker is the sensor. CheckMate is the software that runs on your PC. You use CheckMate to set up Checker mm mm 4.

Checker is the sensor. CheckMate is the software that runs on your PC. You use CheckMate to set up Checker mm mm 4. Quick Reference About Checker Checker is the sensor. CheckMate is the software that runs on your PC. You use CheckMate to set up Checker. Minimum PC Requirements Microsoft Windows 2000 or Windows XP 400MHz

More information

System DISTRIBUTEUR C ONSEIL DEPUIS MVS-8000 Series. MVS-8500 and MVS-8500e Hardware Manual

System DISTRIBUTEUR C ONSEIL DEPUIS MVS-8000 Series. MVS-8500 and MVS-8500e Hardware Manual System DISTRIBUTEUR C ONSEIL DEPUIS 1 9 8 5 MVS-8000 Series MVS-8500 and MVS-8500e Hardware Manual October 2009 The software described in this document is furnished under license, and may be used or copied

More information

VISION IMPACT+ OCR HIGHLIGHTS APPLICATIONS. Lot and batch number reading. Dedicated OCR user interface. Expiration date verification

VISION IMPACT+ OCR HIGHLIGHTS APPLICATIONS. Lot and batch number reading. Dedicated OCR user interface. Expiration date verification IMPACT+ OCR IMPACT+ OCR is the new Datalogic innovative solution for robust and effective Optical Character Recognition (e.g. expiration date, lot number) for the Food & Beverage industry. The new Datalogic

More information

GigE Vision Cameras. Key Features. Dimension (Unit : mm) Pin map (H/W Rev 2.0 이상 ) LED Indicator. back Pannel. Download (File name)

GigE Vision Cameras. Key Features. Dimension (Unit : mm) Pin map (H/W Rev 2.0 이상 ) LED Indicator. back Pannel. Download (File name) GigE Vision Cameras Key Features (Unit : mm) Mini-size CCD / CMOS GigE camera Camera standard - GenICam, GigE Vision Trigger input range : +3.3V~24V(Photo coupler) PoE 지원 (2Tap 모델제외 ) Pin map (H/W Rev

More information

LAUREL. Laureate Rate Meter & Totalizer with Functions A+B, A-B, AxB, A/B, A/B-1 ELECTRONICS, INC. Features. Description

LAUREL. Laureate Rate Meter & Totalizer with Functions A+B, A-B, AxB, A/B, A/B-1 ELECTRONICS, INC. Features. Description Description LAUREL ELECTRONICS, INC. Features Laureate Rate Meter & Totalizer with Functions A+B, A-B, AxB, A/B, A/B-1 Arithmetic functions A+B, A-B, AxB, A/B, A/B-1 applied to rate or total for channels

More information

Absolute encoders - SSI

Absolute encoders - SSI Features Encoder multiturn / SSI Optical sensing Resolution: singleturn 14 bit, multiturn 12 bit Compact design Cost-efficient mounting High reliability by self-diagnostics Counting direction input Available

More information

LAUREL ELECTRONICS, INC.

LAUREL ELECTRONICS, INC. Description LAUREL ELECTRONICS, INC. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations Features Available for turbine flow meter pulse signals

More information

Datasheet Giganetix Board Camera GC2591M-BL GC2591C-BL

Datasheet Giganetix Board Camera GC2591M-BL GC2591C-BL Datasheet Giganetix Board Camera GC2591M-BL GC2591C-BL SMARTEK Vision Business Class Products at Economy Prices SMARTEK Vision s board level version of the Giganetix compact camera series provides you

More information

Visionscape Product Information

Visionscape Product Information Visionscape Product Information Visionscape 4.0 Update Visionscape for GigE Machine Vision NOVEMBER 2009 Please use this selling sheet together with the previous Visionscape selling sheet, available on

More information

RMC70 MOTION CONTROLLER STARTUP GUIDE. With wiring diagrams. Motion Control and More

RMC70 MOTION CONTROLLER STARTUP GUIDE. With wiring diagrams. Motion Control and More RMC70 MOTION CONTROLLER STARTUP GUIDE With wiring diagrams Motion Control and More RMC70 Startup Guide Where to Get Help Video Tutorials In RMCTools, on the Help menu, click Video Tutorials. RMCTools Help

More information

LAUREL. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations ELECTRONICS, INC.

LAUREL. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations ELECTRONICS, INC. Description LAUREL ELECTRONICS, INC. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations Features Available for turbine flow meter pulse signals

More information

IEI emerge MicroNode Install and Setup Guide. Contents

IEI emerge MicroNode Install and Setup Guide. Contents IEI emerge MicroNode Install and Setup Guide Contents Connecting power and the network to the MicroNode... 2 Using Power over Ethernet (PoE)... 3 or... 3 Using a 12 VDC power supply... 3 Connecting and

More information

MobileView Junction Box

MobileView Junction Box Installation Instructions MobileView Junction Box (Catalog Number 2727-MRJB2) English The MobileView Junction Box (2727-MRJB2) integrates the following terminals into the control system: MobileView Guard

More information

Basler. CMOSIS models with Camera Link and up to 340 fps

Basler. CMOSIS models with Camera Link and up to 340 fps Basler Area Scan Cameras CMOSIS models with Camera Link and up to 340 fps Ground-breaking price starting at 299 euros Gigabit Ethernet interface with PoE Camera Link interface for high throughput with

More information

Strain gauge Measuring Amplifier GSV-1A8. Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB

Strain gauge Measuring Amplifier GSV-1A8. Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB Strain gauge Measuring Amplifier GSV-1A8 Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB GSV-1A8USB SubD1 (front side) GSV-1A8USB M12 (front side) GSV-1A16USB (rear side) GSV-1A8USB K6D (front side)

More information

MODEL DRIVER Ic Ip VDC

MODEL DRIVER Ic Ip VDC Provides Mounting & Connections for Stepnet Module CANopen Stepping Driver FEATURES Develop & Debug Stepnet projects then transfer design to OEM pc board. MODEL DRIVER Ic Ip VDC -075-01 STM-075-07 5 7

More information

COGNEX Checker 200 Series Reference

COGNEX Checker 200 Series Reference COGNEX Checker 00 Series Reference Checker 00 Series Products and Accessories Dimensions and Features Getting Started Working Distance and Field of View Adjusting Focus Changing Lenses Mounting Checker

More information

IEEE 488/USB BUS INTERFACES

IEEE 488/USB BUS INTERFACES IEEE 488/USB BUS INTERFACES USBParallel Digital Interface Provides 40 user configured digital I/O lines. Inputs TTL/CMOS and contact closures. Drives 48 ma. Automatic event and status change detection.

More information

Datasheet Giganetix BL Series

Datasheet Giganetix BL Series Datasheet Giganetix BL Series SMARTEK Vision Business Class Products at Economy Prices SMARTEK Vision s latest board level version of the Giganetix camera series provides you with the freedom to create

More information

Manta G-917. Description. 9.2 Megapixel GigE compliant machine vision camera. Benefits and features:

Manta G-917. Description. 9.2 Megapixel GigE compliant machine vision camera. Benefits and features: Manta G-917 Versatile 9.2 Megapixel camera 10.1 fps at full resolution Power over Ethernet option Video-iris lens control Description 9.2 Megapixel GigE compliant machine vision camera Manta G-917 is a

More information

8600 RTU Serial Port Status Cable Assembly for PCM v1.8 25x86 LP Drawings

8600 RTU Serial Port Status Cable Assembly for PCM v1.8 25x86 LP Drawings 8600 RTU Serial Port Status Cable Assembly for PCM-4862 1 v1.8 25x86 LP Drawings 8600 RTU Serial Port Status Cable Assembly for PCA-6135L 2 v1.8 25x86 LP Drawings 2572 RS-232 Status Board Connection 3

More information

MouldFlo Wiring Manual

MouldFlo Wiring Manual MouldFlo Wiring Manual Copyright (C) 2013 Move Innovation ApS http://www.moveinnovation.dk Table of Contents Introduction... 2 MouldFlo I/O (MFIO)... 3 Power Supply Connection... 4 Manifold Connector Ports...

More information

EyeCheck Smart Cameras

EyeCheck Smart Cameras EyeCheck Smart Cameras 2 3 EyeCheck 9xx & 1xxx series Technical data Memory: DDR RAM 128 MB FLASH 128 MB Interfaces: Ethernet (LAN) RS422, RS232 (not EC900, EC910, EC1000, EC1010) EtherNet / IP PROFINET

More information

DMX-K-DRV. Integrated Step Motor Driver + (Basic Controller) Manual

DMX-K-DRV. Integrated Step Motor Driver + (Basic Controller) Manual DMX-K-DRV Integrated Step Motor Driver + (Basic Controller) Manual Table of Contents 1. Introduction... 4 Features... 4 2. Part Numbering Scheme... 5 3. Electrical and Thermal Specifications... 6 Power

More information

Copy Machine Reader. Installation and Setup Guide

Copy Machine Reader. Installation and Setup Guide Copy Machine Reader Installation and Setup Guide CONTENTS 1 COPY MACHINE READER INSTALLATION 1 Overview 1 Reader Specifications 3 CR1120/CR1122 INSTALLATION 3 Copier Interface 3 AC Electrical 3 Communications

More information

Overview. Features CHAPTER

Overview. Features CHAPTER CHAPTER 2 This chapter provides these topics that describe the Catalyst 2955 switch, hereafter referred to as the switch. Features, page 2-1 Front-Panel Description, page 2-3 Rear-Panel Description, page

More information

Cognex MVS-8000 Series

Cognex MVS-8000 Series Cognex MVS-8000 Series MVS-8100D and CDC Cameras Hardware Manual October 2006 Distribué par : 2 rue René Laennec 51500 Taissy France Fax: 03 26 85 19 08, Tel : 03 26 82 49 29 Email : hvssystem@hvssystem.com

More information

GSV-3USBx2 3,5mV/V 4,2V

GSV-3USBx2 3,5mV/V 4,2V x2 3,5mV/V 4,2V Highlights Powered via USB port Sampling rate 10 khz Data rate 1...1000 Hz straingage quarter, half, full bridges Built-in bridge supplement 350 Ohm Optionally also for displacement transducers

More information

Aport-214PG FreeRTOS Programmable Device Server Hardware Guide

Aport-214PG FreeRTOS Programmable Device Server Hardware Guide Aport-214PG FreeRTOS Programmable Device Server Hardware Guide Version: 1.0 2018 APR. Copyright Artila Electronics Co., Ltd. All Rights Reserved Trademarks The Artila logo is a registered trademark of

More information

User Manual PCIE-1172/1174. Reference Manual

User Manual PCIE-1172/1174. Reference Manual User Manual PCIE-1172/1174 Reference Manual Copyright The documentation and the software included with this product are copyrighted 2016 by Advantech Co., Ltd. All rights are reserved. Advantech Co., Ltd.

More information

KRAMER ELECTRONICS LTD. USER MANUAL MODEL: RC-76R/RC-78R Room Controllers. P/N: Rev 5

KRAMER ELECTRONICS LTD. USER MANUAL MODEL: RC-76R/RC-78R Room Controllers. P/N: Rev 5 KRAMER ELECTRONICS LTD. USER MANUAL MODEL: RC-76R/RC-78R Room Controllers P/N: 2900-300253 Rev 5 Contents 1 Introduction 1 2 Getting Started 2 2.1 Achieving the Best Performance 2 2.2 Safety Instructions

More information

PB600/H1 BASIC SYSTEM

PB600/H1 BASIC SYSTEM PB600/H1 Embedded & Industrial PCs INTERNATIONAL PRODUCTS AND CONFIGURATIONS PB600/H1 BASIC SYSTEM PB600/H1 basic configuration Intel Celeron M 1.5GHz 256 MB RAM kit HDD 40GB 2.5" SATA No FDD Power supply

More information

NetLinx NX Integrated Controller NX-3200 (FG )

NetLinx NX Integrated Controller NX-3200 (FG ) DATA SHEET NetLinx NX Integrated Controller NX-3200 (FG2106-03) Overview The NX-3200 / NetLinx NX Integrated Controller is a programmable network appliance specifically designed to control AV and building

More information

Research Concepts RC2500 Antenna Interface Unit (AIU) Board Set

Research Concepts RC2500 Antenna Interface Unit (AIU) Board Set Research Concepts RC2500 Antenna Interface Unit (AIU) Board Set A board set has been developed that can be incorporated into an AIU for an RC2500 antenna controller. This board set is the basis of RC2500

More information

Acuity 1000 Hardware Guide Rev A, July 2001

Acuity 1000 Hardware Guide Rev A, July 2001 Acuity 000 Hardware Guide Rev A, July 200 EM-20396-A Acuity 000 Hardware Guide Rev A, July 200 Copyright 999 RVSI Acuity CiMatrix This manual and the software described in it are copyrighted, with all

More information

4.7 Expansion Module MAC00-FS1/FS4

4.7 Expansion Module MAC00-FS1/FS4 MAC00-FS4 With M12 connectors MAC00-FS1 With D sub connectors TT1068GB 4.7.1 High speed serial RS485 module MAC00-FS1 and FS4 Introduction The MAC00-FS1 and FS4 are used for high speed RS485 communication

More information

Installing Your 1394 Drive Interface Module

Installing Your 1394 Drive Interface Module Installation Instructions Installing Your Drive Interface Module (Catalog Number -DIM) Introduction This publication provides installation instructions for adding the Drive Interface Module to your system.

More information

Industrial 2-port Gigabit High Power Plus PoE++ Injector, 24VDC Input

Industrial 2-port Gigabit High Power Plus PoE++ Injector, 24VDC Input Industrial 2-port Gigabit High Power Plus PoE++ Injector, 24VDC Input Features Supports 2x10/100/1000Base-T(X) for power and data Fully compliant with IEEE802.3at/802.3af standard Auto protection for Over

More information

This document describes the features of the National Instruments IC-317x and contains information about mounting and operating the device.

This document describes the features of the National Instruments IC-317x and contains information about mounting and operating the device. USER MANUAL IC-317x Industrial Controller with Reconfigurable I/O This document describes the features of the National Instruments IC-317x and contains information about mounting and operating the device.

More information

Valve terminal RE-10 with Multi-pin, AS-Interface or bus connection 4 12 valve stations, 300 Nl/min (0.305 Cv)

Valve terminal RE-10 with Multi-pin, AS-Interface or bus connection 4 12 valve stations, 300 Nl/min (0.305 Cv) Type of connection = AS = B1 = B6 Order code RE-10/08-M-1-060 Series Number of stations Multi-pin: 4, 6, 8, 10, 12 Bus versions: 4, 8, 12 Electrical options M-1 = Multi-pin D-Sub plug AS3 = AS-Interface

More information

SK TU4-IOE-M12-C Part Number

SK TU4-IOE-M12-C Part Number SK TU4-IOE-M2-C Part Number 275 28 256 IO Extension Only qualified electricians are allowed to install and commission the module described below. An electrician is a person who, because of their technical

More information

UCBB dual port breakout board user's manual

UCBB dual port breakout board user's manual UCBB dual port breakout board user's manual 1/14 Contents 1 Features 2 Dimensions 3 Connectors 3.1 Screw terminals 3.2 IDC ports 3.3 Powering 3.4 Outputs 3.5 Inputs 4 LED indicators 5 Example connections

More information