2/2005. ABB Technology SOLUTIONS. The corporate technical magazine of the ABB Group in South Africa and the sub-saharan Africa region

Size: px
Start display at page:

Download "2/2005. ABB Technology SOLUTIONS. The corporate technical magazine of the ABB Group in South Africa and the sub-saharan Africa region"

Transcription

1 ABB Technology SOLUTIONS The corporate technical magazine of the ABB Group in South Africa and the sub-saharan Africa region

2 IN THIS ISSUE 4 Frequency Response Analysis of a Power Transformer Power transformers are designed to withstand mechanical forces that arise from the shipping or transportation, as well as subsequent in-service events. Possible damage may lead to core and winding movement. At ABB Powertech Transformers the Sweep Frequency Response Method is used to detect mechanical damage. 12 To measure is to know ABB was awarded the condition monitoring contract at the Eskom Kendal Power Station in May ABB is responsible for ensuring availability of plant and reducing maintenance costs through using condition monitoring tools such as vibration and oil analysis on the turbine auxiliary plant, boiler, coal, and ash plants. 7 P3: Pulp Production Planning The on-line planning of pulp & paper production is a precise and sophisticated process. To achieve a product of the desired composition, texture and quality, the right mix of chemicals must be applied under the right conditions. Even slight deviations can adversely affect the output. ABB s pulp and paper online production optimiser helps meet these objectives. Material flows between subprocesses are simulated and forecasts computed from the present state. Mill behaviour can be optimised and operating decisions supported by a powerful tool Protection Modelling Interoperability according to IEC means the capability of two or more intelligent electronic devices (IEDs) from one, or several vendors to exchange information and to use it in the performance of their functions and for correct co-operation. Projects and Products ABB is the technology leader in two crucial areas of industry: electrical power and automation technologies. In this new section of ABB Technology Solutions we look at some of the latest developments at ABB. Delegation from Poland visits mining operations in South Africa. TECHNOLOGY SOLUTIONS is published by ABB South Africa. info@za.abb.com Address: ABB Park, 3 Eglin Road, Sunninghill Postal: Pvt Bag X37, Sunninghill, 2157 Telephone: Facsimile: Managing Editor: Chesney Bradshaw chesney.bradshaw@za.abb.com Editorial Panel: Richard Becker richard.becker@za.abb.com Ntaga Mojapelo ntaga.mojapelo@za.abb.com Shivani Chetram shivani.chetram@za.abb.com Jacqueline Burn jacqueline.burn@za.abb.com Mark Chan Yan mark.chanyan@za.abb.com Andrew Williamson andrew.williamson@za.abb.com This publication was designed, compiled and produced on behalf of ABB South Africa by M&M Publications (Pty) Ltd. PO Box 1644, Saxonwold 2132 Johannesburg, South Africa. Whilst the compilation and production of ABB Technology Solutions is done with great care and attention and every effort is made to prevent mistakes, neither ABB in Southern Africa nor its principles or subsidiaries, nor M&M Publications (Pty) Ltd. accept responsibility for any errors or the consequences thereof. 2

3 NEWS BRIEFS & EDITORIAL Key Assets Products, People One of the key focus areas for ABB in South Africa is to deliver world class engineered solutions to its customers, by integrating our products into systems. ABB achieves this goal at a remarkably high level of quality by being a technology-driven company with two class-leading assets its products and its people. The product portfolio is especially noteworthy for its range. We cover almost every electrical component used by utility and industrial customers, from extra high voltage switchgear and transformers, right down to panel lights and wiring terminals; from advanced process optimisation software to industrial robots. This range of products is complimented by comprehensive application know-how in most areas required by our utility and industrial customers. To facilitate this delivery of engineered solutions, we have a dedicated department that focuses on providing these systems in each of the core divisions of Power Technologies and Automation Technologies. Over time ABB has built a very versatile group of engineering and project management resources, both in terms of the range of application areas; as well as the aspects of the projects in which we become involved. These ranges are comprehensive: Johan de Villiers GM: Process and Manufacturing Automation The application areas include - the manufacturing of switchgear, machines and transformers; power station control systems; building of substations; substation automation; power system communications; electrical network control; robotics; pulp and paper mills; metal processing; mining and minerals processing; cement production and the construction of petrochemical plants. Our projects involvement can include: consulting; sales; tendering; design; engineering; programming; manufacturing; testing; installation; commissioning; training and service. Therefore, to win business and then sustain it across this breadth of activity, requires the South African operation and our engineers who can achieve world-leading performances, on every project we deliver. To help us achieve this goal, we have developed an engineering career path guide which succeeds in attracting and retaining top people in the fields of automation and power technology systems. This guide doesn t only help to recognise good engineers, it focuses on keeping them doing excellent engineering work for as long as possible. It is driven by an objective mechanism of recognition and reward and helps to ensure that we deploy these vital resources in the best possible way in the whole organisation. The guide provides a complete career path starting with junior and trainee engineers through to project and design engineers and ultimately to senior project engineers, technical specialists and fully-rounded broad spectrum consultants. It comes back to the start: one cannot lead the market in our high-technology environment without impeccable products and people. ABB South Africa succeeds by constantly ensuring those vital cornerstones. Readership Survey Winners: Jackets are on their way to the first three lucky readers who completed and returned the survey carried in ABB TS 1/2005. They are: Chris Hockaday, Principal Engineer, Mintek Patrick Taylor, Special Projects Manager, Petro SA Michael Mabija, Electrical Manager, Nampak Corrugated Cape You can still win a jacket! Our ABB Technology Solutions Reader Survey 2005 continues and you can still win a jacket over the next few weeks. Just click your way through the ABB website ( to the readership survey, open the document on screen and send it in. Do it now! Another THREE jackets have been made available, and will go to the three names drawn from all those who complete the survey and send it in. Good Luck!! 3

4 TRANSFORMERS Frequency Response Analysis of a Power Transformer Power transformers are designed to withstand mechanical forces that arise from the shipping or transportation of transformers, as well as subsequent in-service events. Possible damage may lead to core and winding movement. To detect these movements the frequency response analysis (FRA) method is used. FRA measures the frequency response of passive elements (RLC) of apparatus. In transformers the FRA measures the impedance of the windings over a wide range of frequencies and compares the results of these measurements with a reference set. The main advantage of the FRA method is its ability to detect faults, especially mechanical damage to the windings that cannot always be detected by other means. Two different FRA techniques exist: the Sweep Frequency Response Method (SFRA) and the Low Voltage Impulse method (LVI). The Sweep Frequency Response Method injects a wide range of frequencies by making a frequency sweep using a sinusoidal signal. The signal is generated using a network analyser, which is also used to measure the voltage and to manipulate the results. The Low Voltage Impulse (LVI) method injects the wide range of frequencies required as a voltage impulse into one terminal. The voltage at another terminal, or current passing through the winding connected to the terminal, or any of the other windings is measured. It is possible to measure several voltages and currents simultaneously. The signals are filtered, sampled and stored in the time domain. They are then transferred to the frequency domain and the transfer function is calculated [1]. Measurement technique The most commonly used circuit for FRA measurement is shown in figure 1. Figure 1a shows the FRA instrument where S is the injected signal; R and M are the reference and the measured signals respectively. For a single-phase transformer, the test will be performed in three different configurations as indicated by 1, 2 and 3 at the transformer terminals. The first measurement is performed between the high voltage winding and its neutral, the second between the low voltage winding and its neutral, and the third is the inter-winding (HV-LV). In a three phase situation, nine tests will be performed i.e. six per phase and three inter-winding. S R M a Figure 1: FRA measurement in a single-phase transformer. The Sweep Frequency Response Analysis At ABB Powertech Transformers, the SFRA method is used. The method is applied on new power transformers to make signatures, or fingerprints. At a later stage when the transformer has been in service and has been through a number of faults, these signatures are used as a base for comparison. Comparisons could be made with individual phases, or with sister units. SFRA is also done on units that have been in service for some time in order to detect any displacements within the active part. SFRA measurement was performed on a 500 MVA, 400/132/22kV autotransformer. The connection diagram is shown in figure 2. The number of tests to be conducted for an autotransformer with a tertiary winding is 15 (See table 1). Since the HV winding has a tapchanger, two sets of tests are conducted with the tapchanger at different positions for each test set. This is done in order to check whether the problem is on the tapped section of the winding, or not. 1 H V 2 3 b L V 4

5 TRANSFORMERS Test # Measure A11- a2 B11- b2 C11- c2 a2- YN b2- YN c2- YN 3A2-3C2 3B2-3A2 3C2-3B2 A11-3A2 B11-3B2 C11-3C2 a2-3a2 b2-3b2 c2-3c2 Per Phase Per Phase Per Phase Inter-winding Inter-winding Table 1: Tests required for a three-phase autotransformer with tertiary winding. HV LV A11 B11 C11 YN a 2 b 2 c 2 3A2 3B2 3C2 region above 3 khz. Now the attenuation and the phase shift of the high frequency sine wave passing through the winding are determined by the inductive and capacitive nature of the network. However, the inductive characteristics are determined by the leakage flux coupling. In this region the winding response becomes less dependent on the magnetic circuit; hence the traces of the three phases converge and become similar. At very high frequencies (over 100 khz), the sinusoidal signal mostly travels outside the winding and reflect the other elements in a transformer (e.g. leads, support insulation etc). The magnitude and the phase of the transfer function in that frequency region are influenced by the inductive/capacitive/ resistive nature of these elements. TV Figure 2: Winding connection diagram of an autotransformer with a tertiary winding. Results interpretation Results are displayed as plots of magnitude and phase of the transfer function. The results can be displayed either in linear, or log scale. Figure 3 shows the magnitude response (in log scale) for the SFRA test conducted on the transformer as specified above. Figure 3 compares traces of the individual phases, i.e. LV to Star neutral for each phase. The Per-phase measurement The per-phase measurement targets the individual phase of a given winding. At low frequencies, the influence of capacitance is negligible and the winding behaves as an inductor. The magnetic circuit of the core determines the inductive characteristics. The phase angle is around 90 degrees, indicating the inductive nature of the total impedance. The magnetic flux coupled with the outer phases, a2-yn (white trace) and c2-yn (blue) in Figure 3 shows that outer windings face a different reluctance than the flux coupled with the middle phase, b2-yn (red trace). According to [3], the middle phase trace should differ from the traces of the outer phases, which correlate very closely with each other. As the frequency increases, the capacitive effects start to dominate and the phase angle quickly approaches +90 degrees in the Figure 3: Per-phase measurement, magnitude comparison of the three phases. Inter-winding measurements The Inter-winding measurements target the space between two windings in a given phase. Since the other transformer terminals are left floating during this measurement, the effects of the magnetic circuits are excluded. The response is more capacitive from the low frequencies up to the higher frequencies. Comparing with sister units At the moment SFRA is designed in such a way that the data is based only on a subjective comparison of traces. For the initial measurement, the traces are analysed for changes between responses of the three phases of the same transformer and changes between responses of transformers of the same design [3]. The response of this transformer was compared with the response of similar transformers. 5

6 TRANSFORMERS The second transformer was also a 500MVA, 400/132/22 kv of the same design as the previous one. Two traces were compared, A11-a2 T1, the first 500 MVA transformer and A11-a2 T2 is the second transformer. It can be seen from figure 4 that the two traces correlate very closely with each other. In some areas one trace is on top of the other. This then gives some kind of surety to the customer, that the transformers were designed the same way. It also proves that the manufacturing processes and the assembly were done almost exactly the same way. Figure 4: Comparison of two 500 MVA sister units. Conclusion FRA can be used to detect winding and core displacement in a transformer. It is important to have a fingerprint of the FRA response of a new transformer. This serves as a base for comparison in future when the transformer has seen a number of faults. Transformers of the same design (sister units) should have the same response. References [1] Tenbohlen S, Ryder S.A, Making Frequency Response Analysis Measurement: A comparison of the Swept Frequency and Low Voltage Impulse Methods, XIII International Symposium on High Voltage Engineering, Netherlands [2] Rahman M, Hashim H, Ghosh P.S, Frequency Response Analysis of power transformer, Electrical Eng. Department, Univeriti Tenaga Nasional, aupec03/papers/057%20hashim%20full%20paper.pdf. [3]. Doble Engineering, SFRA user guide, Sweep Frequency Response Analysis, Document 72A , Rev. B, 06/02. Contact Max Chauke ABB Powertech Transformers Tel: max.chauke@za.abb.com 6

7 P3: PULP PRODUCTION PLANNING On-line planning of pulp & paper production Pulp and paper making is a precise and sophisticated process. To achieve a product of the desired composition, texture and quality, the right mix of chemicals must be applied under the right conditions. Even slight deviations can adversely affect the output. The plant s advanced control system must maintain the desired quality under normal operating conditions. Additionally, it must react to disturbances. It must also permit individual sub-systems to be throttled to save energy at times when it is expensive and allow them to be closed down for maintenance all while keeping output as close to the desired level as possible. ABB s Pulp and Paper online production optimiser helps meet these objectives. Material flows between sub-processes are simulated and forecasts computed from the present state. Mill behaviour can be optimised and operating decisions supported by a powerful tool.

8 PULP & PAPER TECHNOLOGY Background Integrated pulp and paper mills are complex systems. The workflow consists of many interdependent sub-processes. Disturbances at one of the stages can quickly propagate to other steps and lead to considerable production losses, quality deviations and wastage of material. It often takes more than eight hours before the result of a control action has taken full effect in the production process well into the next crew s shift. Furthermore, the operation and supervision of the different process sections are divided between different control rooms and hence different operators. Production changes and disturbances directly affect income. It is difficult for operating crews to consider all variables involved in this complex system simultaneously. Predicting the effects of change and taking the necessary actions require appropriate support. The challenge The increased recirculation of process streams due to environmental constraints in the pulp mill processes makes the recovery cycle increasingly sensitive to disturbances. These lead to slow oscillations in the chemical composition at different points in the production cycle, in turn causing quality deviations, reduced yield and increasing consumption of chemicals. Pulp and paper mills consume considerable heat and electric power and therefore energy management presents considerable potential for savings. Depending on the location of the production bottleneck, energy costs can be optimised by better use of buffer tank volumes: sections with great heat demand can be operated at reduced load during periods with high electricity prices and buffers refilled when prices are low. Pulp and paper mills consume considerable heat and electric power and hence energy management presents considerable potential for savings. Previous improvement schemes have attempted to minimise losses and quality deviations by identifying ideal operation conditions. However, the cost of reaching these conditions is not considered. To be truly useful, an optimisation must consider processes dynamically. Only in this way can it be used to evaluate remedial actions against disturbances, or for operation strategy changes. Such a tool must optimise mill operations by balancing supply and demand between sub-systems. Every sub-system has to be fed with material, and sufficient supply must be available for the sub-system to produce as required. The system must be as robust as possible towards disturbances, or partial closures for maintenance (for example through buffering) and provide a common operating strategy for the whole mill. The system minimises: Deviation from the production plan. Cost of make-up chemicals. Deviation from preferred liquor composition. Production loss through disturbances. Energy costs. It supports decision-making in real time through: Identification of production bottlenecks. Identification of faulty measurements. Generic process diagram of pulp and papermaking process. 8

9 PULP & PAPER TECHNOLOGY Preparation of the mill for maintenance stops. Better decision support for mill management. On-line production optimisation. Pilot project Pulp & Paper On-Line Production Optimiser is an Industrial IT application for real time optimisation. A pilot installation is in progress at Billerud s Gruvön Mill 2, a large integrated pulp and paper plant in Sweden. This mill typically produces metric tons of paper annually. It consists of six paper machines, three fibre lines and a coating machine. The pulp mill is supervised from five control rooms. It produces sack and kraft paper, containerboard and market pulp. The mill has recently invested in a new recovery boiler and evaporation plant to raise capacity and eliminate production constraints. To ensure that the anticipated increase in production capacity is achieved, the company is implementing an on-line production optimiser and expects it to boost production and reduce consumption of chemicals to a value of several millions of US dollars annually. The goals were to minimise the following: Variation in active production chemicals composition. Cost of make-up chemicals. Production losses due to disturbances. Variation in amount of active production chemicals in storage. Variation of the distribution of active production chemicals in the system. Billerud s Gruvön Mill. These goals were met by estimating the state of process variables based on mass balance modelling, and searching for the set of control variables to meet the objectives at minimal operational cost. Implementation Modelling The dynamic mass balance of the complete mill is modelled. The modeling is based on descriptions of all components in the system. These components are categorised into object type groups such as: streams, production units, measurements and calculated properties. Production unit examples are digester, pulp tank, black liquor tank, lime kiln and paper machine. Measurement examples are flow, tank level, sulfidity, effective alkali, reduction efficiency, black liquor density and alkali charge. Streams are connectors between the process units and described by the total flow and by the concentrations of the different components that are relevant for each stream. Measurements are connected to either production units or to streams. The pilot mill system with production units, streams and measurements has the following sizes: 25 Production units. 38 Buffer tanks. Approx. 250 streams or pipes. Approx. 250 measurements or observations. Approx variables. Multiple mill functions are considered in the optimisation. Each production unit consists of equations describing the time dependent relationships between all incoming and outgoing streams and manipulated variables connected to the unit. These relationships may be 9

10 PULP & PAPER TECHNOLOGY State estimation: To determine the current state, the sum of all measurement noises (uncertainties) is minimised. The noise levels at the optimum provide excellent information for sensor, or process diagnostics. Noise values are tracked in the database and are used to identify faulty sensors or model refinements. Optimisation: The productionplanning problem is formulated similarly to a model predictive control problem. The optimisation criteria consist of different terms, quadratic and linear, and include terms to enable the following functions: Customised trend describing issue in focus. Minimisation of deviation from set-point trajectories of any variable. One example is the paper machine production plan with its production rates and recipes. These set-points are automatically imported from the scheduling system. The paper machine is often re-scheduled at two-hour intervals. Other common examples are tank level set-points and preferred concentrations of active production chemicals. Limiting the number of changes of the manipulated variables. Too many adjustments of manipulated control variables, as for example production rate in lime kiln, are to be avoided. Minimisation of costs (such as make-up chemical cost). Web-based graphical display with some common properties published on the customer intranet. Maximising revenues from main products and byproducts. One example of byproduct may be power production supplied to the grid. considered as a gigantic dynamic mass balance for the complete mill and are represented by a system of differential and algebraic non-linear equations. When these are discretised in time, the corresponding number of variables to be optimised can approach To be able to couple the process model to the measurements, a model of each sensor or lab measurement is required. The measurements are related to the state by using methods that consider both uncertainty of the models and the observations. The optimisation criterion is minimised subject to the following constraints: Process model. Sensor model. Upper and lower bounds on variables.a maintenance stop is introduced in the optimisation by adjusting the upper bound of the production rate during the stop time for a production object, eg, digester. 10

11 PULP & PAPER TECHNOLOGY The ABB On-line optimiser is a very powerful tool for process control and decision support and is expected to contribute to significant improvements in the process industry for years to come. Upper and lower bounds on change of manipulated variables. Changes in the manipulated variables are sometimes bounded by hard constraints to avoid causing overly aggressive trajectories. For example, a digester should not change its production rate at more than a given rate. The production planning should start from the current value of the state estimation. The optimisation results are used as a basis for production planning. Simulation Following the optimisation, a simulation is performed. This provides an indication of the effectiveness of the strategy and predicts how long the process can run before tanks over- or under fill, production goals are missed etc. This simulated trajectory is compared to the original plan. On-line Optimisation The automatically scheduled calculation 3 includes a state estimation, future optimisation and a simulation. This cycle is repeated approximately four times an hour. What-if analysis: Several what-if analyses can be started at any time on historical or future scenarios to evaluate alternative strategies and paths. Solution Output: In the engineering user interface, many aspects of the model can be changed and all property values from measurement, estimation, optimisation or simulation viewed. A customised trend view with many history and future data of given properties is generated in a couple of minutes and the trend configuration can be saved for later use. As soon as a trend view is created, any user can access this on the intranet web. From the web based user interface the most important computation result may be viewed from any PC connected to the mill intranet or internet. It is also possible to perform the most important interaction with the system through this interface, e.g. information of maintenance stop duration and stop time etc. Client expectations Benefits: Increased paper production. Savings in make-up chemicals. More stable quality of active production chemicals. On-line identification of production bottlenecks can be easily viewed by the web based user interface indicating current and future bottlenecks. Improved decision support for production management. When operation decisions are made, one must consider many secondary conditions in the mill, the on-line optimiser provides invaluable alternative scenarios for production. Common operation strategy for all shifts and control rooms. By using the on-line optimiser, operation management can systematically prioritise between different objectives and targets. When the preferred prioritisation is configured in the database and the optimiser s recommendation adopted, it is easier to motivate the operation strategy. More efficient preparation of the mill prior to maintenance stops is desirable. When a maintenance stop is introduced in the prediction horizon, the optimiser automatically considers this constraint to minimise production loss. It is also possible to evaluate a change in maintenance stop time and quantify the consequence of a longer than expected stop. Identification of faulty measurements by using state estimation diagnostic results. This is a brand new product in ABB s portfolio. The on-line production optimiser employs new and advanced methods, capitalising on the impressive evolution in computing power. Large mill systems including the complete chemical balance and energy management coupled with dynamic production rates can now be optimised in real time using a large number of on-line measurements. The optimiser uses general methods, which is why it can easily be applied to other applications, or system types. The on-line production optimiser is also the missing link between advanced process control and Collaborate Production Management system (CPM) to support the planning function for the integrated pulp & paper mills. The ABB Online optimiser is a very powerful tool for process control and decision support and is expected to contribute to significant improvements in the process industry for years to come. Authors Ulf Persson Thomas Lindberg Lars Ledung Per-Olof Sahlin ABB Automation Technologies AB Västerås, Sweden ulf.x.person@se.abb.com Contact Mark Sheldon ABB South Africa Tel: mark.sheldon@za.abb.com 11

12 CONDITION MONITORING To measure is to know ABB was awarded the condition monitoring contract at the Eskom Kendal Power Station in May ABB is responsible for ensuring availability of plant and reducing maintenance costs through using condition monitoring tools such as vibration and oil analysis on the turbine auxiliary plant, the boiler plant, and coal, ash and auxiliary plants. Thermography is used to detect deficiencies on the unit transformers. While Laser Alignment and balancing is utilised to provide a pro-active service to ensure proper alignment and balancing on all rotating equipment. However, during the latter half of 2004 the focus changed to the milling plant due to the number of load losses encountered on this plant. A number of machines were having problems associated to alignment. An alignment specification well below the coupling manufacturer specification was adopted, and this led to decreased failures of motor bearings, gearboxes and pinions and girth gears. During a monthly routine survey a calculated inner race defect was detected on the gearbox input NDE bearing (Figures 1 and 2). It was calculated that the inner race defect should be at 194,6Hz. ABB made the call to replace this bearing. After the bearing was removed ABB inspected the bearing for damage and found a defect as shown in (Figure 4). What is Vibration Analysis? All rotating equipment has its own specific vibration, which is a product of the rotational speed. Therefore, vibration is measured in amplitude at a specific frequency (Hz). The amplitude is measured in either displacement (microns), velocity (mm/s) or acceleration (g s). This will then give you an amplitude at a specific frequency. For example, if one knows the number of teeth on a gear and the rotational speed of that gear you could determine at what frequency your Gearmesh will be in a FFT Spectrum. This calculation can be done for any component of a machine, i.e. bearings, impeller vanes, rotorbars etc. Figure 2: In Figure 2 a once per revolution impacting can be seen which is due to the defect being on the inner race which is turning with the shaft. This impacting occurs when the defect goes into the load zone. Case Studies 1) 1B Mill Figure 1 Figure 3: In fi gure 3 a clear chip mark can be seen on the inner race of the bearing. 12

13 CONDITION MONITORING 2) 2D Mill This gearbox was noted to have a higher than normal gearmesh frequency vibration. This mill was due for a 6000Hr service and it was decided to visually inspect the gears internally for damage. Figure 1 shows this mill compared to an exactly similar machine. Incidentally, when this machine was visually inspected it was found that the cage on the input NDE bearing had also failed. If this cage failed it could have caused significant secondary damage. Figure 3 show the improvement in vibration levels after the gear was rotated 180 degrees so that it meshes on the other tooth profi le. Figure 1 Figure 2 show the Gearmesh frequency vibration with its harmonics. Figure 4 shows the damage on the gear tooth. Figure 5 shows the broken cage. 13

14 CONDITION MONITORING What is thermography? Thermography is the science of making an unseen temperature visible. Thermography is also a dominating method for temperature fault diagnostics and is an integral part of a preventive maintenance programme. Thermography inspection can be performed while the plant is in operation and actual temperatures can be measured without disturbing the production process. It is accepted as the most reliable and effective non-destructing method for testing temperatures. By using thermography we are now able to categorise faults by measuring the temperature of a fault, and subtracting it from the reference temperature and then recommend an action by experienced based standards. Thermography is used today in a wide field of applications for example: electrical, mechanical, civil and medical. What is oil analysis? Oil can be associated with the life blood of a machine. Early detection of machine defects will show very early in the oil analysis. The first indications of wear will show up in the oil, even though there will be no indication in vibration analysis as not enough wear has taken place to generate a vibration associated with a specific component of a machine. Dirt in oil will create wear, thus oil has to be kept as clean as possible. The only way to ensure plant availability is to perform both oil and vibration analysis. Contact ABB Automation Technologies Francois van Eeden Tel: veedenfr@eskom.co.za 14

15 PROTECTION MODELLING Protection modelling Interoperability according to IEC means the capability of two or more intelligent electronic devices (IEDs) from one, or several vendors to exchange information and to use it in the performance of their functions and for correct co-operation. Data transfer for utility networks is historically a one-way procedure, with data flowing from a simple sender to a highly sophisticated receiver, which interprets the data. In most cases an empoyee reads and understands the data with the help of his comprehensive background. An example is the master-slave communication commonly used in the past, for example the information interface of protection devices according to IEC Interoperability is much more than simple data transfer, but provides for information exchange between two, or more devices of similar intelligence. both the station level (e.g. with the operators work place LN IHMI) and the process level (e.g. with the circuit breaker LN XCBR). If the data model of the circuit breaker (LN XCBR) resides in a breaker IED integrated in the switchgear, or in an I/O card of the bay controller IED, depends on the existence of a serial link ( process bus ), or parallel wires between the bay and process level. The receiver has to understand not only the structure (syntax) of the data, but also its meaning, i.e. the semantics in the context of the process and of his tasks. The modelling approach of IEC All functions performed in substations have been split into the smallest entities, which communicate with each other. These entities, or objects called Logical Nodes (LN) contain all function related data and their attributes to be communicated. The LNs have a standardised mnemonic name of four letters. Instances of these LNs may be implemented single or multiple in any IED. The data is accessed by defined services. Logical nodes for common applications are grouped into Logical Devices (LD), maybe one for control and another for protection. All these objects and services are the base of the function model. Figure 1 - Vertical function structure for protection (a,b) and control (c) with (b,c) and without (a) process bus. Since functions are implemented in devices, the function model has to be complemented by a physical device (PD) model, which describes the common properties of the device. The common device properties are described in the LN LPHD (Logical Node for Physical Device). The Logical Nodes classes can be instantiated several times on the device, implementing its functionality. If not mentioned specifically, we refer to LNs in the context of modelling. The data model, including its services, is mapped to a mainstream communication stack consisting of MMS, TCP/IP, and Ethernet; time critical messages directly to the link layer of the Ethernet. The system, including the configuration, is described by the Substation Configuration description Language (SCL) in XML. Modelling functions Vertical function structures Most functions have a vertical structure, for example they reside with their core functionality at bay level, and communicate with Figure 2 - Horizontal function structure for a line protection scheme with distance protection. Horizontal function structure Some logical nodes exist in many instances in one level and communicate horizontally with each other. One example is the distance protection. Its LN class is called PDIS. The class definition contains three types of data, i.e. identification data like naming, status information data like start and operate (trip), and setting data. For modelling a device distance protection, one instance of PDIS per zone shall be implemented, 15

16 PROTECTION MODELLING i.e. PDIS1 for zone 1, PDIS2 for zone 2, etc. The semantics of the different instances may be given in the description attribute of data Name Plate (NamPlt). The instances of PDIS may also communicate with instances on the other side of the line according to the protection scheme applied. Instances of PSCH co-ordinate the start (Str) and operate (Op) of PDIS instances and maybe auxiliary functions like time overcurrent protection (PTOC) according to this scheme. The result of the co-ordination is a trip via PTRC (trip conditioning) to the local circuit breaker (XCBR). Data dependencies The Logical Nodes (LN) defines the data and the related server. To model the data flow, inputs from other LNs can also be described by the Substation Configuration description Language (SCL). Designing devices In this paragraph we will look at the design of a device, by investigating how state-of-the-art functions can be applied to the IEC functional and data model. Here we are not referring to mapping the IEC model of parts 7 to a protocol this is already done in IEC61850 parts 8 and 9 in a standardised way. Further, we limit ourselves to the modelling functions of a device. Functions within the system have been handled above. Application of the device Each IED is a physical device. IEC provides the logical node LPHD for modelling the physical device: Physical (Hardware) health. Communication problems with statistical counters. Power supply health with statistical counters. As all LNs must reside in some logical device (LD), this applies also for above LNs. If you have only one LD, then naturally they reside inside it, otherwise they reside in the specially named logical device LD0, together with a LLN0, which contains common data for all LNs of a LD. In this second case it is recommended to reserve LD0 only for this purpose, and for definition of all communication related data sets and control blocks. This Figure 3 - Typical model of a combined device for protection and control leaves the other LDs completely open for functional modelling, and you do not have to touch them at all for communication and system engineering at the IEC level (see Figure 3). Mapping existing functionality If you have IEDs with an existing functionality and want to map this to IEC 61850, you have to cope with some problems when things do not match: Some general mandatory functionality like LD level Mode functionality does not exist. Some mandatory data points do not exist. Some mandatory data attributes do not exist. Data or data attributes exist, but with other data type or other coding. Services cannot be supported the way specified in IEC The provision of missing, but mandatory features can be provided at the following levels: IED internal programme, firmware or application level. IED communication driver for IEC The selection between these possibilities depends on the generality of the problem in the IED, and on the amount of application configuration effort for a real project. If the conversion is restricted to a certain LN type, then it should be solved near the LN implementation. If it concerns a specific common data class (CDC), or is valid for data objects (DATA) like Mod, which occur in more than one LN, then it is better solved at IED driver level. Example: Modelling an IEC device The following illustrates some of the problems and possible solutions with a mapping of the IEC fault indications (information number IN) of the distance protection function to IEC At the first glance this looks good. All IEC signals belonging to distance protection have been mapped (the missing information numbers IN only belong to transformer differential). One problem emerges for IN 74 and 75: two different binary signals are mapped to one enumeration type signal. Furthermore, we see that a lot of LNs are used for all signals of the same distance protection function. The difference between the distance backup I>> (PIOC1) and other possible independent over current functions (PTOC2, PIOC3), or earth fault functions (PTOC4, PIOC5) can no longer be seen by standardised identifications. However, is this necessary in this case? If yes, grouping by prefix (see later) offers a possible solution. On the other hand, IEC LNs have a lot more mandatory data objects, which should be handled: The mandatory settings can be provided just as static values to be readable via the IEC stack. The needed values can be provided via the IED SCL file. 16

17 PROTECTION MODELLING IEC IEC , -7-3 IN Description LN DATA Attribute Comments to LN or DATA 64 start/pick-up L1 PTRC Str phsa Protection trip conditioning 65 start/pick-up L2 PTRC Str phsb 66 start/pick-up L3 PTRC Str phsc 67 Start N/ pick-up PTRC Str neut 68 general trip PTRC Op general 69 trip L1 PTRC Op phsa 70 trip L2 PTRC Op PhsB 71 trip L3 PTRC Op phsc 72 trip I>> (back-up operation) PIOC1 Op general Instant. Overcurrent 73 fault location X in ohms RFLO FDOhm mag Fault location 74 fault forward/line PTRC Str dirgeneral DATA no Boolean another value in the same attribute 75 fault reverse/busbar PTRC Str dirgeneral 76 teleprotection signal transmitted PSCH ProTx stval Teleprotection scheme 77 teleprotection signal received PSCH ProRx stval 78 zone 1 PDIS1 Op general Distance protection zone2-6 PDIS2 PDIS6 Op general One PDIS instance for each zone 84 general start/pick-up PTRC Str general Protection trip conditioning 85 breaker failure RBRF OpIn general Breaker failure 90 trip I> PTOC2 Op general Time Overcurrent 91 trip I>> PIOC3 Op general Instant. Overcurrent 92 trip IN> PTOC4 Op general Time Overcurrent 93 trip IN>> PIOC5 Op general Instant. Overcurrent The mandatory general data objects Beh, Mod, Health, and NamPlt can be provided as read only values. An exception in our 103-example for Mod is the PSCH, for which beneath a status indication also a control command exists (both IN 17). Furthermore, the protection off command and indication (IN 18) should be mapped to LLN0.Mod. Health can be mirrored from LPHD.PhyHealth, if nothing else is available, and be reduced to the states ok and alarm. An exception here again is the PSCH, where the IN 39 (teleprotection disturbed) can be mapped to PSCH.Health. Mod can be statically on, if not provided specially as described before. Beh then is calculated from Mod and Health as defined in 7-4. NamPlt is also statically provided. The mandatory PTOC Str and PDIS Str can be provided statically, values are then always FALSE. The mandatory RFLO FDkm can be calculated from FDOhm and some additional parameter. IEC has some more commands in control direction. From this e.g. the autoreclosure on/off together with the appropriate status indications (IN 16) should be mapped to the RREC.Mod data object. Above examples illustrate most of the principle problems. The mapping of services is not relevant in this context, but only for a protocol stack mapping. Packing of LNs As we have already seen in the 103 example above, it is sometimes necessary to group LNs according to some common functionality, like the distance protection handled above, or all LNs handling the same primary device like the circuit breaker, or for common management like Protection on/off. For grouping of LNs within an IED the IEC provides the following mechanisms: Logical devices. Logical node (LN) prefixes. Grouping with Logical Devices The logical device allows via its logical node LLN0 common management functions for all contained LNs. This is specifically: The data object Mod, which allows to block or switch off all LNs of the logical device at once. The data object Loc, which shows the local / remote state for all process controls within the LD. Typically an IED contains beneath the LD0 for the physical device separate LDs for protection and control according to Figure 3, and very often, additionally for disturbance upload. If an IED controls switches as well as a transformer, then again this is typically separated into different LDs. Simple IEDs containing e.g. just protection might have only one LD, which then manages all contained LNs. As long as this grouping is function oriented, it is recommended to name the LDs (beneath the mandatory LD0) according to IEC If you make top down design of the SA functionality, then you might also group LNs according to LDs, if you want to 17

18 PROTECTION MODELLING have a common management function for them. These functional LDs are then later allocated to IEDs as needed and as available. After this process the LNs for the physical IEDs are added as needed. Grouping with Logical Node Prefix The prefix allows a functional grouping for engineering or naming purpose within a LD, without any common management functions. This corresponds to what has been called the horizontal function structure above. Seen from the device modelling and engineering these might contain pre-engineered function parts within an IED fulfilling one common purpose. A typical grouping has already been mentioned above: all LNs for distance protection get a common prefix, e.g. 21 according to IEEE / ANSI notation, and the independent backup overcurrent function gets another (or no) prefix to separate it. The prefix can also be used to distinguish and denote different usages of the PTOC related function, e.g. first step or second step overcurrent, earth current protection etc. Related to the 103 example this could give the following groups: Prefix (acc. IEEE/ANSI) Grouped LNs PDIS1, PDIS2, PDIS3, PDIS4, PDIS5, 21_ PDIS6, PIOC1, PTRC, RFLO, PSCH, RBRF 51_ PTOC2, PIOC3 67N_ PTOC4, PIOC5 Table 1 prefixing for protection related LNs. Another typical grouping, which is more control related, is the following: Prefix (acc. IEC 61346) Grouped LNs QA1 (circuit breaker) QB1 (busbar isolator BB1) QB2 (busbar isolator BB2) QE1 (earthing switch) CSWI1, CILO1, XCBR1 CSWI2, CILO2, XSWI2 CSWI3, CILO3, XSWI3 CSWI4, CILO4, XSWI4 Table 2 prefixing for control related LNs. Preconfiguration IEC defines semantics on LN and data object level. However, the detailed functionality of a LN also depends on its binding to the process. A typical example here is the interlocking logic (LN CILO), which looks different for a bus bar disconnector than for an earthing switch or a line disconnector. One way to show a special CILO implementation according to the place of the switch in the single line diagram is to use prefixes, as shown in Table 2 above. Another, more general possibility is to model the appropriate part (e.g. bay) of the plant with links to the LNs in the substation section of an SCL file for this IED. This SCL file then just contains the IED type description, with an empty IED name, as IED section, and the relevant part of the SCL Substation section. Process interface The process interface is modelled in IEC with T, X, Y and Z type logical nodes. These are typically found on process near IEDs, which are often called PISA (Process Interface for Sensors and Actuators), and are connected to protection and control functions via a process bus. If however a protection device is connected directly with cables to the process, then the question arises, if the modelling of the interfaces is necessary at all. There are situations, where the necessity is clear: some interfacing LNs include some basic functionality like monitoring, supervision and command blocking. If the bay level device also provides this functionality, even if in some rudimentary form, then the modelling of the interface is necessary. A typical example is to use TVTR for VT fuse supervision. The rule should be that everything to be visible outside the IED shall be modelled as defined in the standard. This might also open up possibilities not so obvious. An often-used feature is a local/remote switch per bay. This is typically modelled by an LLN0.Loc data object in the control logical device. However, if additional operation directly at the switchgear is possible, and bay level (local) control shall be inhibited, the appropriate Mod or Loc data objects at a LD modelling the switchgear itself, i.e. just containing X and Y type LNs, can be used. Setting groups The standard allows the definition of setting groups and the switching between different setting group value sets. However, there is at most one setting group per LD. So, if a device supports different setting groups, the LNs having data in the same setting group have to be put into the same logical device, and for each setting group there must exist a logical device. Notably it is not possible to have a part of LN data in one setting group, and another part of the same LN in another setting group. In case that an IED has setting groups where the value set activation can be changed online, but value change of parameters within the set is not possible, then an IED can just contain a setting group control block, but identify no parameters as belonging to it. Naturally a setting group might contain changeable parameters as well as hidden parameters, i.e. parameters not visible in the data model. However, the hidden parameters can then not be changed in a standardised way. If a change is not wanted, but the actual value shall nevertheless be documented in a standardised way, this can be done via the SCL file. For parameters outside a setting group this can also be done by only providing read only access to them. Conclusion IEDs with existing functions can be modelled according to IEC with some restrictions, which should not apply for new IEDs. The free allocation, combination and connection of LNs allow to optimise the system architecture and also to implement new functionality. This supports in a standardised way e.g. combined devices for protection and control, which goes beyond IEC The IEC also provides extension rules, which allow also to introduce in a standardised way new LN classes and data for today unforeseen semantic (future proof). This was already explored in the domain of wind-power plants (IEC ). Contact ABB Power Technologies Ross Botha Tel: ross.botha@za.abb.com 18

19 ABB South Africa in bid to save national energy ABB in South Africa has signed a voluntary Energy Efficiency Accord, a move that will save the country 12% of energy in the next decade. This agreement was signed as part of Energy Efficiency month, launched by the national Department of Minerals and Energy in May The accord was signed by ABB, together with several South African business organisations and industry associations. This voluntary accord has a strategy that targets a 15% reduction in final energy demand for the industrial sector by 2015, and a 12% improvement in energy-efficiency for the nation as a whole by the same date. As a major business player in this country we see it as our responsibility to contribute towards this effort by promoting and developing energy efficient alternatives, says Clive Govender, Vice President, Sustainability Affairs, ABB South Africa. ABB has started working towards this plan through the implementation of ISO at its sites. Environmental management plans for all our sites have built-in energy efficiency programmes that are monitored regularly, says Govender. We will also assist our customers to meet these targets by supplying them with products and systems that will improve efficiency, productivity and that will help in saving energy. Participation in this initiative is currently voluntary, but will become mandatory when legislated in the next 18 months. ABB wins R57 million order for biggest online utility network in Africa ABB has won a R57 million order for the manufacture, supply, delivery, installation, testing and commissioning of the electrical protection and data communication network for the satellite substations at the City of Tshwane Metropolitan Municipality (CTMM). ABB will provide a data communication network that has the ability to remotely monitor, control and supervise the various components and systems in the electricity distribution network located throughout the Tshwane municipal area. The data communication system will service the 132kV networks, as well as the main 33kV and 11kV satellite substations which cover the areas of Pretoria, Centurion, Mamelodi, Atteridgeville, Soshanguve and Acacia. The contract will be managed by DelportDuPreez (Pty) Ltd, Consulting Engineers on behalf of the CTMM. ABB is pleased to be able to provide the customer with an innovative solution that can be fully integrated with the existing monitoring and communication facilities, says Carlos Poñe, CEO of ABB in South Africa. Some of the devices that the data network will communicate between are control centres, quality of supply recorders, the Supervisory Control and Data Acquisition (SCADA) system, remote energy metering and TCP/IP communication over the extended Wide Area Network (WAN) of the Electricity Department. One of the great strengths of the ABB proposal was the ability to offer an economical teleprotection solution in the form of the TEBIT card (Teleprotection and Binary Unit), says Ndivho Lukhwareni, Strategic Executive Officer of the Electricity Department of the CTMM. ABB hosts mining delegation from Poland ABB s Automation Technologies division recently hosted a group of business people in South Africa from one of the world s largest mining groups, KGHM Polska Miedz SA of Poland. A group of mining managers from KGHM, the world s fourth largest copper producer and second largest silver producer, held discussions with ABB South Africa and ABB Poland s automation heads. They also visited mining operations in South Africa where ABB has excellent references in mine hoists. The combined mining capabilities of both countries emphasised ABB s global portfolio and technology leadership. The visit provided an opportunity to see the differences in technology between Polish and South African mines and to explore future cooperation. The delegation from Poland visiting a South African gold mine. Representatives from KGHM were impressed with the Kopanang mine where ABB is currently working on mine hoists. Kopanang, an Anglogold Ashanti (Pty) Ltd mine, is located in Orkney, Free State. The mine has five hoists in one shaft, which is an unusually high number together. The hoists comprise: 1 mechanically coupled Blair Rock winder, 1 electrically coupled Blair Rock winder and 3 double drum man/material winders. ABB has completed the electrical upgrade of the electrically coupled Blair Rock winder and is currently upgrading one of the double drum man/material winders. The recent upgrade of the Blair winder by ABB included new DCS 600 thyristors, control panels, drivers desks, AHM (Advant Hoist Monitor), and a MCC (motor control centre). ABB Poland is an ABB centre of excellence in power electronics for transforming and rectifying power for railway transportation (used in mines) in applications of up to 3000 V DC. Projects & Products 19

THE MODELING APPROACH OF IEC

THE MODELING APPROACH OF IEC Modeling interoperable protection and control devices for substation automation according to IEC 61850 Klaus-Peter Brand 1, Wolfgang Wimmer 2 Switzerland Summary The standard IEC 61850 Communication Networks

More information

Data Model of the Standard IEC 61850

Data Model of the Standard IEC 61850 Klaus-Peter Brand April 2006 Data Model of the Standard IEC 61850 ABB - 1 - IEC 61850 Data Model Content IEC 61850 The Data Model Refers to IEC 61850-7-y Objects and Logical Nodes Hierarchical Data Model

More information

The Impact of the coming Standard IEC61850 on the Life-cycle of Open Communication Systems in Substations

The Impact of the coming Standard IEC61850 on the Life-cycle of Open Communication Systems in Substations The Impact of the coming Standard IEC61850 on the Life-cycle of Open Communication Systems in Substations Lars Andersson, Klaus-Peter Brand, Wolfgang Wimmer ABB Power Automation Ltd, Switzerland Abstract

More information

IEC meets Industrial IT

IEC meets Industrial IT IEC 61850 meets Industrial IT Lars Andersson, Klaus-Peter Brand, Petra Reinhardt The international electrical engineering community is continuously creating new global standards. These are not only important

More information

Substation Automation Products. Line differential protection RED670 Relion 670 series

Substation Automation Products. Line differential protection RED670 Relion 670 series Substation Automation Products Line differential protection RED670 Relion 670 series For maximum reliability of your power system The RED670 IED (Intelligent Electronic Device) is designed for protection,

More information

/ Charlie Hsu, Sales, PSAC, Power System Division, TWABB, June.2013 IEC The Approach and the Standard. ABB Group July 1, 2013 Slide 1

/ Charlie Hsu, Sales, PSAC, Power System Division, TWABB, June.2013 IEC The Approach and the Standard. ABB Group July 1, 2013 Slide 1 / Charlie Hsu, Sales, PSAC, Power System Division, TWABB, June.2013 IEC 61850 The Approach and the Standard July 1, 2013 Slide 1 Agenda Introduction & revolution The key issues for IEC 61850 Logical Nodes

More information

Benefits, offering and references

Benefits, offering and references DOC ID: 9AKK107045A9180 DISTRIBUTION SOLUTIONS Digital medium-voltage switchgear Benefits, offering and references Contents Digital switchgear for medium-voltage applications Digital switchgear definition

More information

SIPROTEC 5 V7.8 Protection, automation and monitoring for digital substations

SIPROTEC 5 V7.8 Protection, automation and monitoring for digital substations SIPROTEC 5 V7.8 Protection, automation and monitoring for digital substations siemens.com/siprotec5 SIPROTEC 5 Table of content Introduction New functions of V7.8 SIPROTEC 5 - the core of Digital Substation

More information

Application Notes on Generator Protection Schemes

Application Notes on Generator Protection Schemes Application Notes on Generator Protection Schemes Single Line Diagram Examples 1. Introduction The application notes provide selected single line diagrams for the SIPROTEC 4 generator protection device

More information

Substation Automation Products. Transformer protection RET670/650 Relion 670 and 650 series

Substation Automation Products. Transformer protection RET670/650 Relion 670 and 650 series Substation Automation Products Transformer protection RET670/650 Relion 670 and 650 series For reliable protection and control of all types of power transformers and reactors The RET670/650 IEDs (Intelligent

More information

IEC unites low-and medium-voltage

IEC unites low-and medium-voltage 25 PROTECTION AND SAFETY IEC 61850 unites low-and medium-voltage IEC 61850 can be used with ABB s low-voltage (LV) intelligent electronic devices (IEDs) such as medium-voltage (MV) protection relays and

More information

OfprintofarticleinPACWorld,Spring2008

OfprintofarticleinPACWorld,Spring2008 OfprintofarticleinPACWorld,Spring2008 47 identification has non standardized parts. The logical device name as a manufacturer / organisation related structuring is completely free within some syntactical

More information

Factsheet. Power Generation Service Energy efficiency in power generation and water

Factsheet. Power Generation Service Energy efficiency in power generation and water Factsheet Power Generation Service Energy efficiency in power generation and water Opportunity identification Opportunity identification overview The opportunity identification phase of Industrial Energy

More information

IEC OBJECT MODELS OF MULTIFUNCTIONAL PROTECTION RELAYS

IEC OBJECT MODELS OF MULTIFUNCTIONAL PROTECTION RELAYS IEC 61850 OBJECT MODELS OF MULTIFUNCTIONAL PROTECTION RELAYS Alexander Apostolov AREVA T&D Automation Los Angeles, USA alexander.apostolov@areva-td.com Abstract The paper analyzes the functional hierarchy

More information

Deploying Digital Substations: Experience with a Digital Substation Pilot in North America. Harsh Vardhan, R Ramlachan GE Grid Solutions, USA

Deploying Digital Substations: Experience with a Digital Substation Pilot in North America. Harsh Vardhan, R Ramlachan GE Grid Solutions, USA Deploying Digital Substations: Experience with a Digital Substation Pilot in North America Harsh Vardhan, R Ramlachan GE Grid Solutions, USA Wojciech Szela, Edward Gdowik PECO, USA SUMMARY Though IEC 61850

More information

DISCERN SGAM Visio Template User Guide

DISCERN SGAM Visio Template User Guide Distributed Intelligence for Cost-Effective and Reliable Distribution Network Operation DISCERN SGAM Visio Template User Guide Author: OFFIS Date: 22.04.2016 www.discern.eu The research leading to these

More information

Designing a new IEC substation architecture

Designing a new IEC substation architecture Designing a new IEC 61850 substation architecture Gerrit Dogger Senior Product and Application Specialist Cooper Power Systems gerrit.dogger@cybectec.com Garry Tennese Station Integration Specialist Manitoba

More information

POWER GRIDS. We are bridging the gap. Enabling Digital Substations.

POWER GRIDS. We are bridging the gap. Enabling Digital Substations. POWER GRIDS We are bridging the gap. Enabling Digital s. 2 A B B D i g i ta l S u b s tat i o n s ABB s Digital provides customers in the utility sector with unmatched control and efficiency. The digital

More information

An Artificial Intelligence Based Approach for Bus Bar Differential Protection Faults Analysis in Distribution Systems

An Artificial Intelligence Based Approach for Bus Bar Differential Protection Faults Analysis in Distribution Systems An Artificial Intelligence Based Approach for Bus Bar Differential Protection Faults Analysis in Distribution Systems By Eng. Sameh Moustafa Mohamed Abd Elgowad Elbana A thesis submitted to The Faculty

More information

Grid Automation packaged solutions Optimal automation of medium voltage grids

Grid Automation packaged solutions Optimal automation of medium voltage grids Grid Automation packaged solutions Optimal automation of medium voltage grids Application principles of the Zone concept Grid Automation (GA) packaged solutions The zone concept offers a method to analyze

More information

Substation Automation Products. High impedance differential busbar protection REB650 Relion 650 series

Substation Automation Products. High impedance differential busbar protection REB650 Relion 650 series Substation Automation Products High impedance differential busbar protection REB650 Relion 650 series One IED for a wide range of high impedance differential protection applications ABB introduces a new,

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 61850-5 First edition 2003-07 Communication networks and systems in substations Part 5: Communication requirements for functions and device models IEC 2003 Copyright - all rights

More information

Busbar protection REB 670

Busbar protection REB 670 Gunnar Stranne Busbar protection REB 670 Rio de Janeiro April 23-25, 2006 ABB Power Technologies AB 2 3 4 REB 500 is enabled for use with IEC61850 communication Benefits of REB 670 outstanding features

More information

Electrical Integration with Smart Communication

Electrical Integration with Smart Communication Electrical Integration with Smart Communication New possibilities with Industrial Ethernet ABB Group September 24, 2009 Slide 1 Unified Integration Approach MES and Business Systems Knowledge Portals as

More information

This is a preview - click here to buy the full publication

This is a preview - click here to buy the full publication TECHNICAL REPORT IEC TR 61850-7-500 Edition 1.0 2017-07 colour inside Communication networks and systems for power utility automation Part 7-500: Basic information and communication structure Use of logical

More information

ELECTRICAL SUPPORT SERVICES

ELECTRICAL SUPPORT SERVICES ELECTRICAL SUPPORT SERVICES CONNECTING YOU TO SPECIALIST ELECTRICAL SUPPORT SERVICES Ampcontrol is committed to partnering with you to optimise the electrical equipment you have invested in to ensure its

More information

Non-conventional instrument transformers Advanced GIS substations with IEC LE process bus

Non-conventional instrument transformers Advanced GIS substations with IEC LE process bus Non-conventional instrument transformers Advanced GIS substations with IEC 61850-9-2LE process bus Content Towards the digital GIS substations Optimized substation design NCIT for gas-insulated switchgears

More information

Substation Automation Products. Generator protection REG670/650 Relion 670 and 650 series

Substation Automation Products. Generator protection REG670/650 Relion 670 and 650 series Substation Automation Products Generator protection REG670/650 Relion 670 and 650 series A new protection standard for your valuable assets Based on ABB s extensive experience, REG670 and REG650 IEDs (Intelligent

More information

Verification of Utility Requirements on Modern Numerical Busbar Protection by Dynamic Simulation

Verification of Utility Requirements on Modern Numerical Busbar Protection by Dynamic Simulation 111 Verification of Utility Requirements on Modern Numerical Busbar Protection by Dynamic Simulation Z. Gajić (ABB, Sweden) JP Wang / PW Gong / YS Xu (ABB China) ZX Zhou (CERPI, China) Summary Power utilities

More information

IEC SCL - MORE THAN INTEROPERABLE DATA EXCHANGE BETWEEN ENGINEERING TOOLS

IEC SCL - MORE THAN INTEROPERABLE DATA EXCHANGE BETWEEN ENGINEERING TOOLS IEC 61850 SCL - MORE THAN INTEROPERABLE DATA EXCHANGE BETWEEN ENGINEERING TOOLS Wolfgang Wimmer ABB Baden, Switzerland wolfgang.wimmer@ch.abb.com Abstract The IEC 61850 SCL language for Substation Configuration

More information

ISIO 200. Binary Input/Output (I/O) terminal with IEC interface

ISIO 200. Binary Input/Output (I/O) terminal with IEC interface ISIO 200 Binary Input/Output (I/O) terminal with IEC 61850 interface Compact and easy ISIO 200 Put your Binary I/Os where you need them ISIO 200 is a simple and versatile binary I/O terminal with IEC 61850

More information

Applications and Industry Activities

Applications and Industry Activities Applications and Industry Activities Christoph Brunner Switzerland The Contents of IEC 61850, Edition 1 System Aspects Part 1: Introduction and Overview Part 2: Glossary Part 3: General Requirements Part

More information

Earth-fault Relay SPAJ 110 C. Product Guide

Earth-fault Relay SPAJ 110 C. Product Guide Issued: April 1999 Status: Updated Version: C/12.04.2006 Data subject to change without notice Features Low-set neutral overcurrent stage with definite time or inverse time characteristic High-set neutral

More information

MEDIUM VOLTAGE PRODUCTS. UniSec Air-insulated medium voltage secondary distribution switchgear Informed choice for safety

MEDIUM VOLTAGE PRODUCTS. UniSec Air-insulated medium voltage secondary distribution switchgear Informed choice for safety MEDIUM VOLTAGE PRODUCTS UniSec Air-insulated medium voltage secondary distribution switchgear Informed choice for safety 2 UNISEC AIR-INSULATED MEDIUM VOLTAGE SECONDARY DISTRIBUTION SWITCHGEAR Operator

More information

DTRV-EP. COMPLEX DIGITAL PROTECTION FOR 120 kv / MEDIUM VOLTAGE TRANSFORMERS. Application field

DTRV-EP. COMPLEX DIGITAL PROTECTION FOR 120 kv / MEDIUM VOLTAGE TRANSFORMERS. Application field DTRV-EP COMPLEX DIGITAL PROTECTION FOR 120 kv / MEDIUM VOLTAGE TRANSFORMERS Application field The DTRV type of complex transformer protection is designed to protect 120 kv / medium voltage transformers,

More information

AUTOMATED FAULT AND DISTURBANCE DATA ANALYSIS. Special Report for PS#2. Special Reporter: Mladen Kezunovic * U.S.A.

AUTOMATED FAULT AND DISTURBANCE DATA ANALYSIS. Special Report for PS#2. Special Reporter: Mladen Kezunovic * U.S.A. AUTOMATED FAULT AND DISTURBANCE DATA ANALYSIS Special Report for PS#2 Special Reporter: Mladen Kezunovic * U.S.A. This paper gives a set of questions stimulated by twenty one papers submitted by the authors

More information

TFS 2100 Traveling Wave Fault Location System

TFS 2100 Traveling Wave Fault Location System Traveling Wave Fault Location System The most accurate overhead transmission and distribution line fault locator Accuracy: ±150m typical regardless the line length Unaffected by fault resistance Suitable

More information

Substation Automation Products. Bay control REC670/650 Relion 670 and 650 series

Substation Automation Products. Bay control REC670/650 Relion 670 and 650 series Substation Automation Products Bay control REC670/650 Relion 670 and 650 series For optimized control and reliable operation of your switchyard The REC670 and REC650 Bay control IEDs (Intelligent Electronic

More information

Substation automation products. MicroSCADA Pro for substation automation

Substation automation products. MicroSCADA Pro for substation automation Substation automation products for substation automation Perfect control anywhere, anytime is an investment for today and tomorrow. Start, for instance, with monitoring or gateway functionality and integrate

More information

Automation System Solutions

Automation System Solutions Automation System Solutions Automation Systems for Power Grid, Power Plant and Industries NR Electric Corporation Automation for Power Grid Substation Automation System Conventional Substation Automation

More information

SP Energy Networks Business Plan

SP Energy Networks Business Plan SP Energy Networks 2015 2023 Business Plan Updated March 2014 Annex 132kV Substation Plant Strategy SP Energy Networks 29 March 2014 March 2014 Issue Date Issue No. Document Owner Amendment Details 17th

More information

ELECTRICAL, INSTRUMENTATION & CONTROL SYSTEMS

ELECTRICAL, INSTRUMENTATION & CONTROL SYSTEMS ELECTRICAL, INSTRUMENTATION & CONTROL SYSTEMS Presentation by: RANA NASIR ALI General Manager, Power Plants Projects, at PITCO November 02, 2017 ELECTRICAL PLANT CONCEPT The electrical equipment, depending

More information

Pushing the limits. ABB product development based on the IEC standard

Pushing the limits. ABB product development based on the IEC standard Pushing the limits ABB product development based on the IEC 61850 standard JANNE STARCK, STEVEN A. KUNSMAN Since the publication of the first edition in 2004, the IEC 61850 communication standard has practically

More information

FAQ about Drives Technology

FAQ about Drives Technology FAQ about Drives Technology Power supply systems MICROMASTER 4 SINAMICS G120 ID: 25220071 Warranty, liability and support We do not accept any liability for the information contained in this document.

More information

Sensitive Earth-fault Relay SPAJ 111 C. Product Guide

Sensitive Earth-fault Relay SPAJ 111 C. Product Guide Issued: April 1999 Status: Update Version: C/12.04.2006 Data subject to change without notice Features Sensitive low-set neutral overcurrent stage with definite time characteristic High-set neutral overcurrent

More information

UniGear type ZS1. SSC (Switchgear System Connectivity)

UniGear type ZS1. SSC (Switchgear System Connectivity) UniGear type ZS1 SSC (Switchgear System Connectivity) INDEX UniGear type ZS1 SSC (Switchgear System Connectivity) State of the art of M.V. Switchgear 2 Switchgear System Connectivity 2 Fields of Application

More information

Session Five: IEC61850 Based Process Bus Protection Solution for Remote Located Power Transformers

Session Five: IEC61850 Based Process Bus Protection Solution for Remote Located Power Transformers Session Five: IEC61850 Based Process Bus Protection Solution for Remote Located Power 1. Abstract Dinesh Mithanthaya Design Manager, Horizon Power Higher capacity substation power transformers ( 5MVA),are

More information

New Sensor Technology for Broad Distribution of Vibration Data Collection design maintenance systems inc.

New Sensor Technology for Broad Distribution of Vibration Data Collection design maintenance systems inc. New Sensor Technology for Broad Distribution of Vibration Data Collection Introduction In this overview presentation, we will look at some of the issues in distributing the effort to collect vibration

More information

UltraTEV Plus 2 Make Partial Discharge discovery simple.

UltraTEV Plus 2 Make Partial Discharge discovery simple. UltraTEV Plus 2 Make Partial Discharge discovery simple www.eatechnology.com The UltraTEV TM Plus 2 brings together techniques and a wealth of experience and insight to make it easier than ever to avoid

More information

Amsterdam 27 September 2017 David MacDonald

Amsterdam 27 September 2017 David MacDonald Operations & Maintenance facilitating condition based and predictive maintenance to support cost-efficient operation and maximum life-cycle of next generation IEC 61850 systems Amsterdam 27 September 2017

More information

IMP/ 001 / 014 Policy for the Protection of Distribution Networks

IMP/ 001 / 014 Policy for the Protection of Distribution Networks Version:- 1.1 Date of Issue:- July 2016 Page 1 of 39 IMP/ 001 / 014 Policy for the Protection of Distribution Networks 1. Purpose The purpose of this document is to detail the network protection philosophy

More information

Grid Automation Controller COM600 How it fits into the Smart Grid?

Grid Automation Controller COM600 How it fits into the Smart Grid? ABB Oy Distribution Automation Grid Automation Controller How it fits into the Smart Grid? May 27, 2014 Slide 1 1MRS756763 E Content Technical Presentation May 27, 2014 Slide 2 Description Grid Automation

More information

RT12-240V/2.4kW Rectifier Specification

RT12-240V/2.4kW Rectifier Specification The RT12-240V/2.4kW is a switched mode rectifier (SMR) module that delivers up to 2.4kW of output power (and up to 11A output current) into a 240V nominal DC system. The RT12 suits AC supply voltages between

More information

ABB static var compensator stabilizes Namibian grid voltage

ABB static var compensator stabilizes Namibian grid voltage Power ABB static var compensator stabilizes Namibian grid voltage factor! Rolf Grünbaum, Mikael Halonen, Staffan Rudin The spectacular dune landscapes of Namibia are a key factor in the country s booming

More information

Applied Research on AC/DC Integrated Power Supply of Substation Lu Zhigang1, a, Lei Bo1, b, Zheng Yongqiang2, c

Applied Research on AC/DC Integrated Power Supply of Substation Lu Zhigang1, a, Lei Bo1, b, Zheng Yongqiang2, c 4th International Conference on Electrical & Electronics Engineering and Computer Science (ICEEECS 2016) Applied Research on AC/DC Integrated Power Supply of Substation Lu Zhigang1, a, Lei Bo1, b, Zheng

More information

ekorrps MULTIFUNCTIONAL PROTECTION UNIT CONFIGURATION AND GENERAL CHARACTERISTICS LIB

ekorrps MULTIFUNCTIONAL PROTECTION UNIT CONFIGURATION AND GENERAL CHARACTERISTICS LIB MO-067-EN Operation Manual MULTIFUNCTIONAL PROTECTION UNIT CONFIGURATION AND GENERAL CHARACTERISTICS LIB Transformer Substations Secondary Distribution Switchgear Primary Distribution Switchgear Protection

More information

PRC Coordination of Protection Systems for Performance During Faults

PRC Coordination of Protection Systems for Performance During Faults PRC-027-1 Coordination of Protection Systems for Performance During Faults A. Introduction 1. Title: Coordination of Protection Systems for Performance During Faults 2. Number: PRC-027-1 3. Purpose: To

More information

Overview and Application

Overview and Application IEC 61850 Overview and Application Who am I? Rich Hunt Market Development Leader GE Grid Solutions Over 25 years in the power systems industry At GE for 10 years (almost) Member of IEEE PSRC, U.S. Representative

More information

Vibration analysis goes mainstream

Vibration analysis goes mainstream Vibration analysis goes mainstream With advances in sensor, recording, and analysis technology, vibration analysis is now within the reach of even small organizations Fast Forward Measuring the vibrations

More information

UPS5000-E (25-75 kva) Series

UPS5000-E (25-75 kva) Series Battery Integrated Uninterruptible Power System UPS5000-E (25-75 kva) Series HUAWEI TECHNOLOGIES CO., LTD. CONTENTS 02 Solution Overview 03 Customer Benefits 09 System Architecture and Key Components 12

More information

Exercise 2. Single Bus Scheme EXERCISE OBJECTIVE DISCUSSION OUTLINE. The single bus scheme DISCUSSION

Exercise 2. Single Bus Scheme EXERCISE OBJECTIVE DISCUSSION OUTLINE. The single bus scheme DISCUSSION Exercise 2 Single Bus Scheme EXERCISE OBJECTIVE When you have completed this exercise, you will be familiar with electric power substations using the single bus scheme with bus section circuit breakers.

More information

Sensitive definite time or inverse time earth-fault stage for back-up residual earthfault

Sensitive definite time or inverse time earth-fault stage for back-up residual earthfault Issued: April 1999 Status: Updated Version: B/09.11.2001 Data subject to change without notice Features Sensitive restricted earth-fault protection stage for fast, selective earth-fault protection Sensitive

More information

Transformer Protection and Control RET630 Numerical transformer protection in medium voltage networks

Transformer Protection and Control RET630 Numerical transformer protection in medium voltage networks GUIDEFORM SPECIFICATION Transformer Protection and Control RET630 Numerical transformer protection in medium voltage networks The freely configurable relay is intended for protection, control, measurement

More information

Implementing the protection and control of future DC Grids

Implementing the protection and control of future DC Grids Implementing the protection and control of future DC Grids Hengxu Ha, Sankara Subramanian Innovation and Technology Department, SAS, Alstom Grid 1. The challenge of the DC Grid protection 1 High speed

More information

ELG4125: System Protection

ELG4125: System Protection ELG4125: System Protection System Protection Any power system is prone to 'faults', (also called short-circuits), which occur mostly as a result of insulation failure and sometimes due to external causes.

More information

Data Migration Plan (40) Fingrid Oyj

Data Migration Plan (40) Fingrid Oyj 1 (40) Fingrid Oyj FI10728943, VAT reg. 2 (40) Table of Contents Definitions... 5 1 Summary... 6 2 Introduction... 7 2.1 Datahub... 7 2.2 Members of the data migration plan... 8 2.3 Datahub's data migration

More information

Substation monitoring and control

Substation monitoring and control Substation monitoring and control Part 3. Substation Automation Author Peter Johansen, www.jomitek.dk In the preceding 2 articles the topics of measurement techniques for voltage and current has been covered.

More information

AN ADVANCED APPROACH TO IDENTIFY INRUSH CURRENT AND HARMONICS USING ARTIFICIAL INTELLIGENCE FOR POWER SYSTEM PROTECTION

AN ADVANCED APPROACH TO IDENTIFY INRUSH CURRENT AND HARMONICS USING ARTIFICIAL INTELLIGENCE FOR POWER SYSTEM PROTECTION AN ADVANCED APPROACH TO IDENTIFY INRUSH CURRENT AND HARMONICS USING ARTIFICIAL INTELLIGENCE FOR POWER SYSTEM PROTECTION Tawheeda Yousouf 1, Raguwinder Kaur 2 1 Electrical engineering, AIET/PTU Jalandhar,

More information

Digital Substation Overview of Technology, Industry

Digital Substation Overview of Technology, Industry Digital Substation Overview of Technology, Industry Trends and Standardization Efforts 4th International Scientific & Technical Conference Actual Trends in Development of Power System Protection and Automation

More information

Integrated monitoring system for power transformers and hydro generators as an asset management and "smart grid" component. Miroslav Poljak, Ph.

Integrated monitoring system for power transformers and hydro generators as an asset management and smart grid component. Miroslav Poljak, Ph. Integrated monitoring system for power transformers and hydro generators as an asset management and "smart grid" component Miroslav Poljak, Ph.D Monitoring - Definition On-line monitoring system (MS) is

More information

Keor HPE UPS. THREE-PHASE UPS from 60 to 300 kw GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Keor HPE UPS. THREE-PHASE UPS from 60 to 300 kw GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES Keor HPE UPS THREE-PHASE UPS from 60 to 300 kw GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES LEGRAND UPS SERVICE continuity ENERGY efficiency SUPERIOR PERFORMANCES Legrand, world

More information

Relion 615 series Transformer Protection and Control RET615 Ver. 2.0 Technical Presentation

Relion 615 series Transformer Protection and Control RET615 Ver. 2.0 Technical Presentation Relion 615 series Transformer Protection and Control RET615 Ver. 2.0 Technical Presentation Distribution Automation May 13, 2010 1MRS756901 A Slide 1 Content RET615 Technical Presentation highlights May

More information

DRS-LA413. Circuit Breaker Failure Relay. Operating Principle DRS-LA413. Operating Principle. Revision: 2 from Dwg.No.: DIL

DRS-LA413. Circuit Breaker Failure Relay. Operating Principle DRS-LA413. Operating Principle. Revision: 2 from Dwg.No.: DIL Circuit Breaker Failure Relay Operating Principle Revision: 2 from 2005-02-25 Edition: 2005-02-25 _CBF-description_eng.doc Page 1 /14 Table of Contents: 1 GENERAL DESCRIPTION 4 2 FUNCTIONAL DESCRIPTION

More information

Communication Gateway COM 610. Product Guide

Communication Gateway COM 610. Product Guide Communication Gateway COM 610 Product Guide Issued: September 2004 Status: Updated Version: D/17.10.2006 Data subject to change without notice Features Protocol conversion gateway for substation automation:

More information

SIPROTEC 5 New features of V7.5

SIPROTEC 5 New features of V7.5 SIPROTEC 5 New features of V7.5 siemens.com/siprotec5 New Features for SIPROTEC 5 Release 7.50 Feeder Protection Ground Fault Detection (Pulse Detection, Harmonic Detection) Automatic Load Shedding Vector

More information

p. 1 p. 9 p. 26 p. 56 p. 62 p. 68

p. 1 p. 9 p. 26 p. 56 p. 62 p. 68 The Challenges and Opportunities Faced by Utilities using Modern Protection and Control Systems - Paper Unavailable Trends in Protection and Substation Automation Systems and Feed-backs from CIGRE Activities

More information

T500 DUALTACH. JAQUET T500 DualTach. 2 channel measurement & monitoring instrument 2 CHANNEL TACHOMETER I N C H A R G E O F S P E E D.

T500 DUALTACH. JAQUET T500 DualTach. 2 channel measurement & monitoring instrument 2 CHANNEL TACHOMETER I N C H A R G E O F S P E E D. 1-08 T500 DUALTACH 2 CHANNEL TACHOMETER JAQUET T500 DualTach 2 channel measurement & monitoring instrument JAQUET T500 DualTach 2 channel measurement and monitoring instrument for demanding machine protection

More information

SACE Emax 2 Specification guide

SACE Emax 2 Specification guide SACE Emax 2 Specification guide Specification Number: 26 01 20.17 Product Name: LOW VOLTAGE POWER CIRCUIT BREAKERS PART 1 GENERAL NOTE: ( ) Indicates option or a selection is to be made for quantity or

More information

ABB SACE A division of ABB S.p.A. L.V. Breakers Via Pescaria 5, Bergamo - Italy Phone: Fax:

ABB SACE A division of ABB S.p.A. L.V. Breakers Via Pescaria 5, Bergamo - Italy Phone: Fax: ABB SACE A division of ABB S.p.A. L.V. Breakers Via Pescaria 5, 24123 Bergamo - Italy Phone: +39 035 395.111 Fax: +39 035 395.306-433 abb.com/lowvoltage Copyright 2017 ABB. All rights reserved. Specifications

More information

Power Quality of Commercial Buildings - Advanced

Power Quality of Commercial Buildings - Advanced Buildings - Advanced Hartford Steam Boiler One State Street P.O. Box 5024 Hartford, CT 06102-5024 Tel: (800) 472-1866 www.munichre.com/hsb May 2017 Background Power quality is a general term used to describe

More information

Voltage regulator. SPAU 341 C 1MRS MBG Issued: July 1998 Status: Revised Version: C/ Data subject to change without notice

Voltage regulator. SPAU 341 C 1MRS MBG Issued: July 1998 Status: Revised Version: C/ Data subject to change without notice Issued: July 1998 Status: Revised Version: C/08.10.2003 Data subject to change without notice Features Comprehensive voltage regulation for power transformers with on-load tapchangers in distribution substations

More information

ABB Surge Arresters Contribution to Power Quality Line Side Protection

ABB Surge Arresters Contribution to Power Quality Line Side Protection James Taylor, Technology Support Manager / Principal Specialist May 2013 ABB Surge Arresters Contribution to Power Quality Line Side Protection May 6, 2013 Slide 1 Availability of electric power supply

More information

MESP TECHNICAL SPECIFICATION FOR A RECTIFIER UNIT CONTROL & PROTECTION SYSTEM FOR USE IN THE 1500V DC TRACTION SYSTEM

MESP TECHNICAL SPECIFICATION FOR A RECTIFIER UNIT CONTROL & PROTECTION SYSTEM FOR USE IN THE 1500V DC TRACTION SYSTEM Engineering Specification Electrical Networks TECHNICAL SPECIFICATION FOR A RECTIFIER UNIT CONTROL & PROTECTION SYSTEM FOR USE IN THE 1500V Version: 1 Issued: March 2014 Owner: Electrical Networks Asset

More information

Protection relays.

Protection relays. Protection relays www.vamp.fi Vamp Ltd Vamp Ltd, with a strong experience of designing devices, is an independent supplier of relays and monitoring equipment. The company has an established reputation

More information

When two become one. JOHAN HANSSON, STEFAN BOLLMEYER The successful. ABB review special report

When two become one. JOHAN HANSSON, STEFAN BOLLMEYER The successful. ABB review special report When two become one IEC 61850 in combination with ABB s award-winning Extended Automation System 800xA is opening doors to new and cost-effective solutions. JOHAN HANSSON, STEFAN BOLLMEYER The successful

More information

Relays - SCADA - Metering

Relays - SCADA - Metering Industrial Ethernet Competence Test Instruments Energy Management Service Complete Solutions Services Quality Protective Relaying Substation Automation, SCADA Relays - SCADA - Metering u Utility SCADA

More information

Enhancing Reliability of Legacy Systems with New Generation Low-Voltage Circuit Breaker Upgrades

Enhancing Reliability of Legacy Systems with New Generation Low-Voltage Circuit Breaker Upgrades Enhancing Reliability of Legacy Systems with New Generation Low-Voltage Circuit Breaker Upgrades May 2012 / 1910DB1202 by Hal Theobald, Product Manager, Schneider Electric Services and Reza Tajali, P.E.,

More information

Power Systems Communications Implementation of IEC61850 in a Substation Environment

Power Systems Communications Implementation of IEC61850 in a Substation Environment Power Systems Communications Implementation of IEC61850 in a Substation Environment 26 October 2009 Reference VEE4700-01 Revision 0 Document Control Document ID: DOCUMENT1 Rev No Date Revision Details

More information

Effective commissioning of bus bar protection systems using a dynamic simulation in the field

Effective commissioning of bus bar protection systems using a dynamic simulation in the field Effective commissioning of bus bar protection systems using a dynamic simulation in the field F Fink *, J Köppel, T Hensler *OMICRON electronics GmbH, Austria, florian.fink@omicron.at, ABB AG, Germany,

More information

Substation Automation Products. Line distance protection REL670/650 Relion 670 and 650 series

Substation Automation Products. Line distance protection REL670/650 Relion 670 and 650 series Substation Automation Products Line distance protection REL670/650 Relion 670 and 650 series For maximum reliability of your power system REL670 and REL650 line distance protection IEDs (Intelligent Electronic

More information

Qualified Active Magnetic Bearing Retrofits for Turbo-expanders

Qualified Active Magnetic Bearing Retrofits for Turbo-expanders WHITE PAPER Qualified Active Magnetic Bearing Retrofits for Turbo-expanders AUTHORS Richard Jayawant, Product Manager, Waukesha Magnetic Bearings Houman Shokraneh, PhD, Director of Engineering, L.A. Turbine

More information

Substation to substation (ss2ss) GOOSE exchange for critical relay operations

Substation to substation (ss2ss) GOOSE exchange for critical relay operations CIGRÉ Canada 21, rue d Artois, F-75008 PARIS (CIGRE-130) Conference on Power Systems http : //www.cigre.org Vancouver, October 17-19, 2010 Substation to substation (ss2ss) GOOSE exchange for critical relay

More information

ABB Automation & Power World: April 18-21, 2011 IEC connectivity, networking and state-of-the-art Relion protection/control technologies

ABB Automation & Power World: April 18-21, 2011 IEC connectivity, networking and state-of-the-art Relion protection/control technologies ABB Automation & Power World: April 18-21, 2011 IEC 61850 connectivity, networking and state-of-the-art Relion protection/control technologies ABB Inc. April 20, 2011 Slide 1 Overview IEC61850 Basics What

More information

Learn IEC Configuration In 30 Minutes

Learn IEC Configuration In 30 Minutes Learn IEC 61850 Configuration In 30 Minutes Wei Huang ABB Inc. Lake Mary, FL, USA Wei.huang@us.abb.com Abstract the myth says IEC 61850 is too complicated to use with a steep learning curve. The traditional

More information

SPECIAL CONSIDERATION OF FEEDER PROTECTION FOR BREAKER-AND-A-HALF CONFIGURA- TIONS. G. Steynberg

SPECIAL CONSIDERATION OF FEEDER PROTECTION FOR BREAKER-AND-A-HALF CONFIGURA- TIONS. G. Steynberg SPECIAL CONSIDERATION OF FEEDER PROTECTION FOR BREAKER-AND-A-HALF CONFIGURA- TIONS G. Steynberg Siemens AG; Energy Sector, Energy Automation, Nuremberg 1. INTRODUCTION The breaker-and-a-half configuration

More information

HID. GE Consumer & Industrial Multilin. High Impedance Differential Module Instruction manual GEK Copyright 2005 GE Multilin

HID. GE Consumer & Industrial Multilin. High Impedance Differential Module Instruction manual GEK Copyright 2005 GE Multilin g GE Consumer & Industrial Multilin HID High Impedance Differential Module Instruction manual GEK-113064 Copyright 2005 GE Multilin GE Multilin 215 Anderson Avenue L6E 1B3 Markham, ON -CANADA T (905) 294

More information

C C CIRCUIT-BREAKERS Moulded-case (MCCB), general. 1. Introduction. 2. General description

C C CIRCUIT-BREAKERS Moulded-case (MCCB), general. 1. Introduction. 2. General description CIRCUIT-BREAKERS C C81-21 CIRCUIT-BREAKERS - Contents 1. Introduction 2. General description 3. Rated voltages 3.1 Rated operational voltage (U e ) 3.2 Rated impulse withstand voltage (U imp ) 3.3 Rated

More information

UTILITIES AND INDUSTRIES OF TODAY: LEADING BY FOLLOWING IEC 61850

UTILITIES AND INDUSTRIES OF TODAY: LEADING BY FOLLOWING IEC 61850 UTILITIES AND INDUSTRIES OF TODAY: LEADING BY FOLLOWING IEC 61850 Clemens Hoga, Gordon Wong Siemens AG Nuremberg, Germany gordon.wong@siemens.com Abstract Substations with protection, control and engineering

More information

Utilization of IEC GOOSE messaging in protection applications in distribution network

Utilization of IEC GOOSE messaging in protection applications in distribution network 9AKK106930A2259 Utilization of IEC 61850 GOOSE messaging in protection applications in distribution network Yogesh Bhamare Head-Product Management, Distribution Automation, ABB Limited, Vadodara, India

More information

Combined Overcurrent and Earth-fault Relay SPAJ 140 C. Product Guide

Combined Overcurrent and Earth-fault Relay SPAJ 140 C. Product Guide Combined Overcurrent and Earth-fault Product Guide Issued: April 1999 Status: Updated Version: C/18.04.2006 Data subject to change without notice Features Three-phase, low-set phase overcurrent unit with

More information