ABB Group - Bob van Evelingen. March 26, 2009 Slide Series. 600-Series. Transmiss. ABB Group - Bob van Evelingen. March 26, 2009 Slide 5
|
|
- Edgar Fisher
- 5 years ago
- Views:
Transcription
1 Arc Protection REA101 REA 101 A01 REA101 REA101 Open Close Bob van Evelingen Seminar / Maart-April 2009 Protection & Testing Relays, Breakers, Busbars, Transformers, Batteries Close March 26, 2009 Slide 1 March 26, 2009 Slide 4 Working Place? REA 101 A Series RE_ REX REF-REM RET54x REF542plus 600-Series 2 I t Transmiss. REF610 REJ603 REF601 REF615 New 670-series RED615 REA101 (Arc) Combiflex SPACOM March 26, 2009 Slide 2 March 26, 2009 Slide 5 SPAJ-SPAM-SPAU Arc Protection REA 101 A01 Sub-Station Automation IEC A02 Trip-Time = 2 8 ms Inter-bay signals using IEC and GOOSE GPS time source Network control center MicroSCADA Pro DCS I> REF615 Monitoring, control, settings Interlocking, shared external signals Time synchronization Station bus IEC Tubes of Polycarbonate Busbar Protection REF542plus March 26, 2009 Slide 3 March 26, 2009 Slide 6 1
2 Feeder Protection REF 615 A03 Line Differential RED 615 A04 March 26, 2009 Slide 7 March 26, 2009 Slide 10 Arc protection REF 615 A03 New ABB-Relays 600-series A05 3. IED A ms GOOSE IED B IEC communication between devices in substations (including GOOSE messaging) GOOSE = Generic Object Oriented Substation Event Power Supply March 26, 2009 Slide 8 March 26, 2009 Slide 11 Line Differential RED 615 A04 Self-Powered Relay REJ 603 A06 20km Relay Power Supply March 26, 2009 Slide 9 March 26, 2009 Slide 12 2
3 Self-Powered Relay REJ 603 A06 3-Phase Testing FREJA300/306 P02 Relay 3* 0-15A 3* 0-35A Test by SVERKER or FREJA March 26, 2009 Slide 13 March 26, 2009 Slide 16 Self-Powered Relay REJ 603 A06 3-Phase Testing (6 currents) FREJA306 P03 Relay March 26, 2009 Slide 14 March 26, 2009 Slide 17 1-Phase Testing SVERKER P01 Testing Relays SVERKER & FREJA P03 I Protection Relays (all manufacturers) Aux. Supply Seminar: Testen Relais Dinsdag 2 juni 2009, ABB I> U Phase angle Control Trip March 26, 2009 Slide 15 March 26, 2009 Slide 18 3
4 Transformer Differential SVERKER & FREJA P03 The relay Terminal is connected directly to main CTs. Auxiliary CTs are simulated numerically by the relay itself. March 26, 2009 Slide 19 March 26, 2009 Slide 22 Transmission Protection 670-series A series A07 Busbar Differential Generator Line Distance Protection, Monitoring and Control March 26, 2009 Slide 20 March 26, 2009 Slide 23 Training & Workshops Training P18 Local & International Combiflex A08 Workshops: Protective Relays Breaker Analyzing Transformer Monitoring Combiflex March 26, 2009 Slide 21 March 26, 2009 Slide 24 4
5 Combiflex / RTXP A08 Protection & Control REF542plus A09 V4 -Display V5 -Display March 26, 2009 Slide 25 March 26, 2009 Slide 28 Protection & Control REF542plus A09 March 26, 2009 Slide 26 March 26, 2009 Slide 29 Protection & Control REF542plus A09 March 26, 2009 Slide 27 March 26, 2009 Slide 30 5
6 Protection & Control REF542plus A09 Transf. & Machine Terminal RET54x / REG54x A11 RET54x Transformer protection with integrated voltage regulator REM54x March 26, 2009 Slide 31 March 26, 2009 Slide Series RE_ REX REF-REM RET54x REF542plus 600-Series Transmiss. REF610 REJ603 REF601 REF series RED615 REX521 A10 REX 521 is a multi-function relay designed for protecting feeders and motors REA101 (Arc) Combiflex SPACOM March 26, 2009 Slide 32 SPAJ-SPAM-SPAU March 26, 2009 Slide 35 Transformer Terminal RET 541/3/5 A14 Monitoring Transformers Transformers P05 Protection & Control Voltage regulator for 4 parallel transf. Differential for 2-Winding CORE Tap-changer Test On-Line Monitoring Gasses & Moisture SFRA Test March 26, 2009 Slide 33 March 26, 2009 Slide 36 6
7 SFRA Transformer Test IDAX P06 DualGround technology TM DCM P09 (S)FRA= (Sweep) Frequency Response Analysis Off-line test A transformer winding is a complex RLC circuit The Impedance of this RLC circuit is measured as function of frequency Changes can be compared over time or between test objects Safe area Both sides grounded (3-phases) March 26, 2009 Slide 37 March 26, 2009 Slide 40 Testing Breakers TM1800 P07 DualGround technology TM DCM P09 Earthing Switch Earthing Switch March 26, 2009 Slide 38 March 26, 2009 Slide 41 Testing Breakers TM1800 P07 One Side Grounded TM DCM P09 Motion Phase L3 Phase L2 Phase L1 0 Time March 26, 2009 Slide 39 March 26, 2009 Slide 42 7
8 DualGround technology TM DCM P09 Breaker Analyzing TM DCM P09 CABA Software Breaker Testing March 26, 2009 Slide 43 March 26, 2009 Slide 46 DualGround technology TM DCM P09 DualGround technology TM DCM P09 TM TM1800 March 26, 2009 Slide 44 March 26, 2009 Slide 47 Testing Breakers TM DCM P09 Testing Breakers Breaker Test P08 EGIL Testing Breakers B10E Testing Coils and Spring Charge Motor March 26, 2009 Slide 45 March 26, 2009 Slide 48 8
9 Programma Products Micro-Ohmmeter Mjölner200/600 P10 G Micro Ohm Overgangsweerstand HV-Breaker Analyzer Schakelaarsnelheidsmeting CONTROL ROOM DualGround Aarding tijdens test Gasses & Moisture Continu meting Gas & Vocht Primary Primair Doorstromen Protection Relays Testen Relais Capacity Batteries Test Accu Capaciteit MV-Breaker Analyzer Schakelaarsnelheidsmeting March 26, 2009 Slide 49 March 26, 2009 Slide 52 Programma Products Programma P04 Primary Current Testing ODEN AT P12 ODEN AT AC-output Current CSU20A Phase Angle PAM360E Relay 400V Type: max 3 min. max 1 sec. 2000A 7000A AT 1S 6V AT 2S 6V *) 4000A 13kA AT 3S 6V *) 4000A 13kA AT 1X 6V *) 2000A 7000A AT 2X 6V *) 4000A 13kA AT 3X 6V *) 4000A 13kA AT 1H 3,6V *) 2600A 11kA AT 2H 3,6V *) 5300A 21kA AT 3H 3,6V *) 7700A 21,9kA *) different output voltages *) verschillende uitgangsspaningen Timer TM200 CT-Test MAGNUS BALTO ADC The TOTAL SYSTEM has to operate correctly March 26, 2009 Slide 50 Programma Products: March 26, 2009 Slide 53 Micro-Ohmmeter Mjölner200/600 P10 Testing DC-Breakers BALTO P11 8,8kg I> MOM=25-40kg A DC A DC Test object: Breakers, Busbars, March 26, 2009 Slide 51 March 26, 2009 Slide 54 9
10 Preventive Maintenance SPACOM A Series Easy Replacement of Power Supply RE_ REX REF-REM RET54x REF542plus 600-Series REF610 REJ603 REF601 REF615 REA101 (Arc) Transmiss. 670-series RED615 Combiflex SPACOM March 26, 2009 Slide 55 SPAJ-SPAM-SPAU March 26, 2009 Slide 58 Preventive Maintenance SPACOM A21 Retrofit Relays REJ 603 A06 More than SPACOM units have been delivered worldwide, since 1984 For ALL Equipment: Life time electrolytic capacitor: 8-12 years March 26, 2009 Slide 56 March 26, 2009 Slide 59 Preventive Maintenance SPACOM A21 Retrofit Relays REF 615 A03 15 cm Incl. wiring March 26, 2009 Slide 57 March 26, 2009 Slide 60 10
11 Retrofit Relays 610/615-series A03 Burn-off Contacts TM DRM P22 15 cm Incl. wiring March 26, 2009 Slide 61 March 26, 2009 Slide 64 Maintenance Breakers TM1800 P07 Burn-off Contacts TM DRM P22 High & Medium Voltage March 26, 2009 Slide 62 March 26, 2009 Slide 65 Testing Vacuum Breaker VIDAR P21 Burn-off Contacts TM DRM P22 DC-Voltage Vacuum Breaker 5ms DC-Test = 1,7x Un AC March 26, 2009 Slide 63 March 26, 2009 Slide 66 11
12 Burn-off Contacts TM DRM P22 Testing Capacity Batteries TORKEL 840 P24 VOLTAGE DROP ALARM STOP TORKEL Win Installation Charger=off TXL for Higher Loads R - + I or Ah = - + Constant March 26, 2009 Slide 67 March 26, 2009 Slide 70 Dynamic Resistance TM DRM P22 Protection & Testing Battery DRM Voltage Current TM1800 or TM1600 DRM Trig + Relay The TOTAL SYSTEM has to operate correctly TORKEL FREJA SVERKER ODEN MJÖLNER March 26, 2009 Slide 68 March 26, 2009 Slide 71 Testing Capacity Batteries TORKEL 840 P23 automation March 26, 2009 Slide 69 March 26, 2009 Slide 72 12
Relion 615 series Transformer Protection and Control RET615 Ver. 2.0 Technical Presentation
Relion 615 series Transformer Protection and Control RET615 Ver. 2.0 Technical Presentation Distribution Automation May 13, 2010 1MRS756901 A Slide 1 Content RET615 Technical Presentation highlights May
More informationMJÖLNER 200 Micro-ohmmeter
Fully automatic testing Micro processor controlled Safe test DualGround and Remote control True DC ripple free current Lightweight suitcase withstands the impact of water, dust or sand Built in thermal
More informationSubstation Automation based on IEC Claes Rytoft ABB Power Systems
Substation Automation based on IEC 61850 Claes Rytoft ABB Power Systems BayNetworks Development of SA SA conventional MMI / Control Board NCC SA with interbay bus NCC SA with interbay & process bus NCC
More informationElectrical Integration with Smart Communication
Electrical Integration with Smart Communication New possibilities with Industrial Ethernet ABB Group September 24, 2009 Slide 1 Unified Integration Approach MES and Business Systems Knowledge Portals as
More informationPower Products. Protection and Control IED Manager PCM600 Product Guide
Power Products Protection and Control IED Manager Product Guide Contents 1. Description............................ 3 2. Tool variants........................... 3 3. Connectivity packages...................
More informationTitle System Substation Commissioning Tests. Reference Number PCP 07 - (RIC Standard: EP SP)
Discipline Engineering Standard - NSW Category Electrical Title s Reference Number PCP 07 - (RIC Standard: EP 99 00 00 02 SP) Document Control Status Date Prepared Reviewed Endorsed Approved Mar 05 Standards
More informationLaurent Sowazi, EPMV-DA/ Africa Channel Partner event, 2016 ABB Distribution Automation Making Grids Smarter. ABB November 23, 2016
Laurent Sowazi, EPMV-DA/ Africa Channel Partner event, 2016 ABB Distribution Automation Making Grids Smarter Slide 1 Distribution Automation Footprint Global deliveries Finland (Vaasa) Home market deliveries
More informationRelion 615 series Feeder Protection and Control REF615 Ver. 2.0 Technical Presentation
Relion 615 series Feeder Protection and Control REF615 Ver. 2.0 Technical Presentation Distribution Automation May 13, 2010 1MRS756407 E Slide 1 Content REF615 Technical Presentation highlights May 13,
More informationProtection and Control REX640 Product Presentation
ABB OY DISTRIBUTION SOLUTIONS Protection and Control REX640 Product Presentation 1MRS758996 A Product introduction Protection and Control REX640 All-in-one protection for any power distribution application
More informationSubstation Automation Products. Generator protection REG670/650 Relion 670 and 650 series
Substation Automation Products Generator protection REG670/650 Relion 670 and 650 series A new protection standard for your valuable assets Based on ABB s extensive experience, REG670 and REG650 IEDs (Intelligent
More informationContent REF615 Technical Presentation
Distribution Automation Relion 615 series Feeder Protection and Control Ver. 2.0 Technical Presentation March 30, 2010 1MRS756407 E Slide 1 Content Technical Presentation highlights March 30, 2010 Slide
More informationRelion 615 series Line Differential Protection and Control RED615 Ver. 2.0 Technical Presentation
Relion 615 series Line Differential Protection and Control RED615 Ver. 2.0 Technical Presentation ABB Oy Distribution Automation July 1, 2009 1MRS756504 B Slide 1 Contents RED615 Technical Presentation
More informationLars Frisk, Frantz Kruger, Integrator Partner Seminar 2012 Bay level product news Relion & supporting products
Lars Frisk, Frantz Kruger, Integrator Partner Seminar 2012 Bay level product news Relion & supporting products Bay level product news Relion & Relion supporting products Relion for generation, transmission
More informationBenefits, offering and references
DOC ID: 9AKK107045A9180 DISTRIBUTION SOLUTIONS Digital medium-voltage switchgear Benefits, offering and references Contents Digital switchgear for medium-voltage applications Digital switchgear definition
More informationSubstation Automation Products. High impedance differential busbar protection REB650 Relion 650 series
Substation Automation Products High impedance differential busbar protection REB650 Relion 650 series One IED for a wide range of high impedance differential protection applications ABB introduces a new,
More informationFeeder Protection REF615 Ver Technical Presentation. ABB Oy Distribution Automation. Prashant Ganoo Regional Product Marketing Manager
ABB Oy Distribution Automation Prashant Ganoo Regional Product Marketing Manager Feeder Protection REF615 Ver. 1.1 Technical Presentation 9/26/2008-1 - 1MRS756407 C Self Introduction Prashant Ganoo B.E.(ELECT),
More informationSubstation Automation Products. Transformer protection RET670/650 Relion 670 and 650 series
Substation Automation Products Transformer protection RET670/650 Relion 670 and 650 series For reliable protection and control of all types of power transformers and reactors The RET670/650 IEDs (Intelligent
More informationMJÖLNER 600 Microhmmeter
Microhmmeter A Megger Group Company Microhmmeter The MJÖLNER 600 is designed to measure the resistance of circuit breaker contacts, bus-bar joints, contact elements in bus-bars and other high-current links.
More informationSensitive Earth-fault Relay SPAJ 111 C. Product Guide
Issued: April 1999 Status: Update Version: C/12.04.2006 Data subject to change without notice Features Sensitive low-set neutral overcurrent stage with definite time characteristic High-set neutral overcurrent
More informationNon-conventional instrument transformers Advanced GIS substations with IEC LE process bus
Non-conventional instrument transformers Advanced GIS substations with IEC 61850-9-2LE process bus Content Towards the digital GIS substations Optimized substation design NCIT for gas-insulated switchgears
More informationCircuit Breaker Analyzer & Timer CAT126
Safe and fast testing with BSG (Both Sides Grounded) Timing and motion measurement 12 timing channels (3x4) for main and resistive contacts 6 timing channels for auxiliary inputs 3 transducer input channels
More informationCircuit Breaker Analyzer & Timer CAT126
Robust design for field use Timing and motion measurement 12 timing channels (3x4) for main and resistive contacts 6 timing channels for auxiliary inputs 3 transducer input channels 4 additional analog
More informationSubstation Automation Products. Line differential protection RED670 Relion 670 series
Substation Automation Products Line differential protection RED670 Relion 670 series For maximum reliability of your power system The RED670 IED (Intelligent Electronic Device) is designed for protection,
More informationProgramma Circuit Breaker Testing Accessories
Programma Item Description TM1800 TM1600 EGIL Cat. No. SOFTWARE AND APPLICATION KITS CABA Win Circuit Breaker analysis software CABA Win incl. Ethernet cross-over cable CG-8000X incl. fiber optics and
More informationSubstation Automation Products. Line distance protection REL670/650 Relion 670 and 650 series
Substation Automation Products Line distance protection REL670/650 Relion 670 and 650 series For maximum reliability of your power system REL670 and REL650 line distance protection IEDs (Intelligent Electronic
More informationDRTS 64. The new generation of advanced test equipment for Relays, Energy meters, Transducers and Power quality meters.
The new generation of advanced test equipment for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual
More informationHigh impedance protection relay
High impedance protection relay Page 1 Issued: April 1999 Status: New Data subject to change without notice Features High impedance type differential current earth-fault protection, so called restricted
More informationEarth-fault Relay SPAJ 110 C. Product Guide
Issued: April 1999 Status: Updated Version: C/12.04.2006 Data subject to change without notice Features Low-set neutral overcurrent stage with definite time or inverse time characteristic High-set neutral
More informationInnovation on Medium Voltage Switchgear
Bruno Rivas, Guarulhos - Brazil, April 2015 Jornadas Técnicas de ABB en Chile Innovation on Medium Voltage Switchgear May 13, 2015 Slide 1 Application 13. Mai 2015 Slide 2 PPMV Brazil Factory Unigear Insourcing
More informationABB Digital medium-voltage switchgear
NAMIBIA AMEU/AEDU MARCH 2018 ABB Digital medium-voltage switchgear Barry Addinall UniGear Digital Contents 1. Digital switchgear 2. Complexity of Distribution networks 3. New technologies using digital
More informationCircuit Breaker Analyzer & Timer CAT66
Safe and fast testing with BSG (Both Sides Grounded) Timing and motion measurement 6 timing channels (3x2) for main and resistive contacts 6 timing channels for auxiliary inputs 3 transducer input channels
More informationSubstation Automation Products. Bay control REC670/650 Relion 670 and 650 series
Substation Automation Products Bay control REC670/650 Relion 670 and 650 series For optimized control and reliable operation of your switchyard The REC670 and REC650 Bay control IEDs (Intelligent Electronic
More informationSM100. On-Line Switchgear Condition Monitoring
On-Line Switchgear Condition Monitoring On-Line Switchgear Condition Monitoring Introduction Weis is a specialist company with over 40 years of experience in the commissioning, testing & maintenance of
More informationRFD-200 TM. Test a Wide Variety of Relays in their Outdo FEATURES AT A GLANCE. Auxiliary AC/DC Power Supply. RFD-200 S2 Ampere Meters
Ergonomic Design a Make Performance RFD-200 TM Vanguard s Model RFD-200 S2 is a portable relay test set that delivers performance verification testing of electromechanical, electronic, and microprocessorbased
More informationLecture 6 Substation Automation Systems
Lecture 6 Substation Automation Systems 1 Course map 2 Contents of the Lecture Part 1 Substation Automation Components & Architectures Substation Automation Functions Communication within the Substation
More informationFundamentals of Circuit Breaker Maintenance. AVO Training Institute, Inc. 2018
Fundamentals of Circuit Breaker Maintenance 1 AVO Training Institute, Inc. 2018 Moderator n Ron Spataro AVO Training Institute Marketing Manager 2 Q&A n Send us your questions and comments during the presentation
More informationRelion 630 series. Load-shedding controller PML630 High performing load-shedding solution for industrial and utility power networks
Relion 630 series Load-shedding controller PML630 High performing load-shedding solution for industrial and utility power networks Integrated load-shedding and protection solution The PML630 is a freely-configurable
More informationDRTS 33. The new generation of advanced three phase relay test set
The new generation of advanced three phase relay test set Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Local control with color display Simultaneously available:
More informationTesting Instruments Manufactured by
Circuit Breaker Dynamic Contact Resistance Meter HISAC Ultima Circuit Breaker Dynamic Test Set with up to Six Channel Dynamic Contact Resistance Meter 24 Binary Channels (4 Main + 4 PIR per Pole, 3 Poles
More informationDistribution Automation, India Product portfolio
Distribution Automation, India Product portfolio Distribution Automation Product portfolio Main protection for MV / LV switchgear Generator / Generator-Transformer protection for machines < 40 MW Fast
More informationUsing the Bitronics 70 Series to Improve Local Monitoring and Control
Automate a Substation and Preserve the Electromechanical Relay Investment Part Two of Four Using the Bitronics 70 Series to Improve Local Monitoring and Control Paul Grabowski - Bitronics Senior Application
More informationLecture 5 Substation Automation Systems. Course map
Lecture 5 Substation Automation Systems 1 Course map 2 1 Contents of the Lecture Part 1 Substation Automation Components Substation Automation Functions Communication within the Substation (Intro) Part
More informationSPA-ZC 302. Profibus-DPV1/SPA Gateway. Product Guide. spa-zc302_rightco300
Profibus-DPV1/SPA Gateway SPA-ZC 302 Product Guide spa-zc302_rightco300 Issued: 25.11.2003 Status: Updated Version: D/16.05.2008 Data subject to change without notice Features Profibus DP Version 1 connectivity
More informationA Current Based, Communication Assisted High Speed Protection System to Limit Arc Energy. Patrick Robinson Altelec Engineering
A Current Based, Communication Assisted High Speed Protection System to Limit Arc Energy Patrick Robinson Altelec Engineering Captured Arcing Fault Event Arc begins as phase A-C, 8ka peak, dies out then
More informationFeeder protection relay SPAA 121 C. Product Guide
Issued: April 1999 Status: Updated Version: C/06.03.2006 Data subject to change without notice Features Two-phase low-set phase overcurrent unit with definite time or inverse time characteristic Two-phase
More informationGrid Automation Controller COM600 How it fits into the Smart Grid?
ABB Oy Distribution Automation Grid Automation Controller How it fits into the Smart Grid? May 27, 2014 Slide 1 1MRS756763 E Content Technical Presentation May 27, 2014 Slide 2 Description Grid Automation
More informationMEDIUM VOLTAGE PRODUCTS. UniSec Air-insulated medium voltage secondary distribution switchgear Informed choice for safety
MEDIUM VOLTAGE PRODUCTS UniSec Air-insulated medium voltage secondary distribution switchgear Informed choice for safety 2 UNISEC AIR-INSULATED MEDIUM VOLTAGE SECONDARY DISTRIBUTION SWITCHGEAR Operator
More informationApproval...6. Current Revision...7. Introduction... 8 About PJM Manuals... 8 About This Manual... 8 Using This Manual...9
PJM Manual 07: PJM Protection Standards Revision: 3 Effective Date: May 24, 2018 Prepared by System Planning Division Transmission Planning Department PJM 2018 Table of Contents Table of Contents Approval...6
More informationVoltage regulator. SPAU 341 C 1MRS MBG Issued: July 1998 Status: Revised Version: C/ Data subject to change without notice
Issued: July 1998 Status: Revised Version: C/08.10.2003 Data subject to change without notice Features Comprehensive voltage regulation for power transformers with on-load tapchangers in distribution substations
More information1) IED Protection and Control Manager PCM 600 Tool (SEP-601) The following subjects will be studied:
1) IED Protection and Control Manager PCM 600 Tool (SEP-601) PCM 600 Introduction and Overview Application Configuration Tool (CAP 531) Signal Matrix Tool, SMT Graphical Display Editor, GDE Parameter Setting
More informationRMS Product Presentation
RMS Product Presentation THE RELAY SPECIALISTS relay monitoring systems pty ltd www.rmpl.com.au Relay Monitoring Systems Pty Ltd 6 Anzed Court - Melbourne - Australia Manufacturing in Australia Company
More informationDTRV-EP. COMPLEX DIGITAL PROTECTION FOR 120 kv / MEDIUM VOLTAGE TRANSFORMERS. Application field
DTRV-EP COMPLEX DIGITAL PROTECTION FOR 120 kv / MEDIUM VOLTAGE TRANSFORMERS Application field The DTRV type of complex transformer protection is designed to protect 120 kv / medium voltage transformers,
More informationEGIL Circuit breaker analyzer
Suitable for testing timing and travel on all circuit breakers with single interrupter per phase Extremely easy-to-use and reliable Two separate timing channels for measurement of auxiliary contacts Analog
More informationSIPROTEC 5 V7.8 Protection, automation and monitoring for digital substations
SIPROTEC 5 V7.8 Protection, automation and monitoring for digital substations siemens.com/siprotec5 SIPROTEC 5 Table of content Introduction New functions of V7.8 SIPROTEC 5 - the core of Digital Substation
More informationTRF-250A. automatic, 3-phase transformer turns ratio finder
TRF-250A automatic, 3-phase transformer turns ratio finder TRF-250A 3-phase transformer turns ratio finder Product Overview The TRF-250A is the battery-powered version of the TRF- 250. Its battery offers
More informationSensitive definite time or inverse time earth-fault stage for back-up residual earthfault
Issued: April 1999 Status: Updated Version: B/09.11.2001 Data subject to change without notice Features Sensitive restricted earth-fault protection stage for fast, selective earth-fault protection Sensitive
More informationEGIL Circuit breaker analyzer
EGIL Suitable for testing timing and travel on all circuit breakers with single interrupter per phase Extremely easy-to-use and reliable Two separate timing channels for measurement of auxiliary contacts
More informationCircuit Breaker Analyzer & Timer CAT126
Circuit Breaker Analyzer & Timer CAT126 Robust design for field use Timing and motion measurement 12 timing channels (3x4) for main and resistive contacts 6 timing channels for auxiliary inputs 3 transducer
More informationEGIL Circuit breaker analyzer
EGIL Circuit breaker analyzer EGIL Circuit breaker analyzer Suitable for testing timing and travel on all circuit breakers with single interrupter per phase Extremely easy-to-use and reliable Two separate
More informationTHE NEW GENERATION OF ADVANCED TEST EQUIPMENTS FOR RELAYS, ENERGY METERS, TRANSDUCERS AND POWER QUALITY METERS.
D R T S 6 6 THE NEW GENERATION OF ADVANCED TEST EQUIPMENTS FOR RELAYS, ENERGY METERS, TRANSDUCERS AND POWER QUALITY METERS. www.isatest.com DRTS 66 The new generation of advanced test equipments for relays,
More informationHigh Impedance Protection Relay SPAE010, SPAE011. Product Guide
SPAE010, SPAE011 SPAE010, SPAE011 1MRS750383-MBG Issued: April 1999 Status: Updated Version: D/21.03.2006 Data subject to change without notice Features High impedance type differential current earth-fault
More informationELG4125: System Protection
ELG4125: System Protection System Protection Any power system is prone to 'faults', (also called short-circuits), which occur mostly as a result of insulation failure and sometimes due to external causes.
More informationWHAT IS A BUS? FUNDAMENTALS OF BUS PROTECTION. Kevin Wright Senior Protection Engineer Sacramento Municipal Utility District
WHAT IS A BUS? FUNDAMENTALS OF BUS PROTECTION Kevin Wright Senior Protection Engineer Sacramento Municipal Utility District 5 WHAT IS A BUS? All connections are at the same voltage. WHAT IS A BUS? All
More informationCT-8000 S3. digital circuit breaker analyzer
CT-8000 S3 digital circuit breaker analyzer CT-8000 S3 digital circuit breaker analyzer Product Overview The CT-8000 S3 is Vanguard's fourth generation EHV circuit breaker analyzer. The CT-8000 S3 is available
More informationSurge Current Generators PG **-****
Surge Current Generators PG **-**** Waveform 8/20 µs Surge current: 40 ka - 100 ka The surge current generators PG **-*** generate standard impulse currents with waveform 8/20 µs according to IEC, EN,
More informationHugo E. Meier, Heidelberg, Germany, June 2014 Integrator Partner Seminar2014 Substation automation trends
Hugo E. Meier, Heidelberg, Germany, June 2014 Integrator Partner Seminar2014 Substation automation trends Substation automation trends Contents Product Portfolio Trends in substation automation Cyber Security
More informationElectrical Test & Measurement Power Product Catalog
Electrical Test & Measurement Power Product Catalog The word Megger is a registered trademark. www.megger.com/us About Megger: You know Megger. Since 1903, the Megger family has provided tools, training
More informationOvercurrent and Arc Protection by Reyrolle Alexander Erokhin. 21, 2017 I Berlin
Overcurrent and Arc Protection by Reyrolle Alexander Erokhin VAR Partner Day September 20-21, 21, 2017 I Berlin Reyrolle Product Range by SIEMENS Challenges We Meet for our Customers Easy-to-use protection
More informationDRTS 66 can test all the following relays
Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual control with color display Simultaneously available: 6 Current and 6 Voltage plus 1 battery simulator outputs
More informationTransformer Protection and Control RET630 Numerical transformer protection in medium voltage networks
GUIDEFORM SPECIFICATION Transformer Protection and Control RET630 Numerical transformer protection in medium voltage networks The freely configurable relay is intended for protection, control, measurement
More informationBusbar protection REB 670
Gunnar Stranne Busbar protection REB 670 Rio de Janeiro April 23-25, 2006 ABB Power Technologies AB 2 3 4 REB 500 is enabled for use with IEC61850 communication Benefits of REB 670 outstanding features
More informationTri-Phase. true 3-phase transformer turns ratio tester
Tri-Phase true 3-phase transformer turns ratio tester Tri-Phase true 3-phase transformer turns ratio tester Product Overview The Tri-Phase can be used as a stand-alone unit or can be computer-controlled.
More informationp. 1 p. 9 p. 26 p. 56 p. 62 p. 68
The Challenges and Opportunities Faced by Utilities using Modern Protection and Control Systems - Paper Unavailable Trends in Protection and Substation Automation Systems and Feed-backs from CIGRE Activities
More informationELECTRICAL, INSTRUMENTATION & CONTROL SYSTEMS
ELECTRICAL, INSTRUMENTATION & CONTROL SYSTEMS Presentation by: RANA NASIR ALI General Manager, Power Plants Projects, at PITCO November 02, 2017 ELECTRICAL PLANT CONCEPT The electrical equipment, depending
More informationDOC Electrical Installation Calculation and Dimensioning
Help ABB SACE A Division of ABB S.p.A., MK-TO, 2011 DOC Electrical Installation Calculation and Dimensioning February 14, 2011 Slide 1 Contents Use cases ABB Software Desktop February 14, 2011 Slide 2
More informationSubstation automation products. MicroSCADA Pro for substation automation
Substation automation products for substation automation Perfect control anywhere, anytime is an investment for today and tomorrow. Start, for instance, with monitoring or gateway functionality and integrate
More informationDGSZV-EP DIGITAL GALVANIC LONGITUDINAL DIFFERENTIAL PROTECTION. Application field
DGSZV-EP DIGITAL GALVANIC LONGITUDINAL DIFFERENTIAL PROTECTION The digital galvanic longitudinal differential protection of type DGSZV-EP is part of device family named EuroProt. This short description
More informationA P P L I C A T I O N
Circuit Breaker timing test set 16 timing channels Motion and speed analyzer Built-in 200 A microohmmeter Up to 4 trip/close coils control Static and dynamic contact resistance measurement Suitable for
More informationDRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters
The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual
More informationPlats för bild på PST2291 med solpanel och en person
PST2200 POWER STATION AND TRANSMISSION LABORATORY PST2200 Power System Simulator with two generators Plats för bild på PST2291 med solpanel och en person PST2291 Solar Power Module General Introduction
More informationSession Five: IEC61850 Based Process Bus Protection Solution for Remote Located Power Transformers
Session Five: IEC61850 Based Process Bus Protection Solution for Remote Located Power 1. Abstract Dinesh Mithanthaya Design Manager, Horizon Power Higher capacity substation power transformers ( 5MVA),are
More informationNumerical motor protection in medium voltage networks Motor Protection and Control REM620
Guideform Specification 1MRS758530 A Numerical motor protection in medium voltage networks Motor Protection and Control REM620 The configurable motor management relay is intended for protection, control,
More informationDistribution Substations Relaying
Distribution Substations Relaying Trends That Will Affect Your Next Design Court H. Weathers, PE August 2018 1 Trend: Increasing Integration 3 ElectromechanincalRelays & RTUs Limited Status (52a) Few Controls
More informationi-pcgrid Workshop 2014 PG&E Order No. 754 Analysis: Protection
i-pcgrid Workshop 2014 PG&E Order No. 754 Analysis: Protection 1 Process PG&E Order No. 754 Analysis Receive Bus List from Planning that Meet the Criteria in Table A Protection Computes Actual Clearing
More informationPower Products. Station Automation COM600 Product Guide
Power Products Station Automation Product Guide Contents 1............................. 3 2. Application............................ 4 3. Parameter setting....................... 5 4. Event and alarm lists...6
More informationCombined Overcurrent and Earth-fault Relay SPAJ 140 C. Product Guide
Combined Overcurrent and Earth-fault Product Guide Issued: April 1999 Status: Updated Version: C/18.04.2006 Data subject to change without notice Features Three-phase, low-set phase overcurrent unit with
More informationSynchro-check relay. Application
Issued: April 1999 Status: Updated Version: B/08.11.2001 Data subject to change without notice Features Two identical operation stages allowing the closing conditions of two separate circuit breakers to
More informationCircuit Breaker Asset Management using Intelligent Electronic Device (IED) Based Health Monitoring
Circuit Breaker Asset Management using Intelligent Electronic Device (IED) Based Health Monitoring Carey Schneider Mike Skidmore Zak Campbell Jason Byerly Kyle Phillips American Electric Power October
More informationIEC unites low-and medium-voltage
25 PROTECTION AND SAFETY IEC 61850 unites low-and medium-voltage IEC 61850 can be used with ABB s low-voltage (LV) intelligent electronic devices (IEDs) such as medium-voltage (MV) protection relays and
More informationSCADA Training - T&D Automation
SCADA Training - T&D Automation Contact us Today for a FREE quotation to deliver this course at your company?s location. https://www.electricityforum.com/onsite-training-rfq This course covers all the
More informationSYMAP R Plug in Variants FI, MI, 87M, TI Technical data
SYMAP R Plug in Variants FI, MI, 87M, TI Technical data 1 Product overview SYMAP R (Retrofit) is a digital protection relay for use in medium and high-voltage power systems. Because of its integrated protection
More informationCircuit Breaker Analyzer System
Programma TM1600 TM Circuit Breaker Analyzer System Modular Design configure the analyzer to your needs Ideal for timing of breakers with multiple breaks per phase 16 Timing Channels and 6 Analog Channels
More informationMNS Platform, low voltage systems Rear Access Power Motor Control Center. Alberto Carini, Global Product Manager
MNS Platform, low voltage systems Rear Access Power Motor Control Center Alberto Carini, Global Product Manager MNS Platform, low voltage systems Add Value to our customers Sales After sales Maximum safety;
More informationCommission Testing Methods for Protection Systems
Commission Testing Methods for Protection Systems Tom Ernst GE Grid Solutions Ken Sletten Minnesota Power Abstract Commission testing should be designed to assure that the protection system is set and
More informationVerification of Utility Requirements on Modern Numerical Busbar Protection by Dynamic Simulation
111 Verification of Utility Requirements on Modern Numerical Busbar Protection by Dynamic Simulation Z. Gajić (ABB, Sweden) JP Wang / PW Gong / YS Xu (ABB China) ZX Zhou (CERPI, China) Summary Power utilities
More information1S20. Arc Fault Monitor Relay. Features. Introduction. ARC Fault Protection
Technical Bulletin Arc Fault Monitor Relay Features Compact, economic design Simple panel mounting for retrofit applications Two or three arc sensor inputs Two high speed tripping duty arc sense output
More informationThis webinar brought to you by the Relion product family Advanced protection and control IEDs from ABB
This webinar brought to you by the Relion product family Advanced protection and control IEDs from ABB Relion. Thinking beyond the box. Designed to seamlessly consolidate functions, Relion relays are smarter,
More informationJehanpour Ranjkesh, Integrator Partner Seminar 2012 Station level product news Automation Controller COM600
Jehanpour Ranjkesh, Integrator Partner Seminar 2012 Station level product news Automation Controller COM600 Contents COM600 Product Overview Business Overview Product News Overview June 12-14, 2012 Slide
More informationPower Products. Station Automation COM600 Product Guide
Power Products Station Automation Product Guide Contents 1.... 3 2. Application... 4 3. Parameter setting... 5 4. Event and alarm lists...6 5. Disturbance and fault record handling... 6 6. Data historian...
More informationCFW-09HD LINE DC LINK POWER SUPPLY
CFW-09HD LINE DC LINK POWER SUPPLY CFW-09HD Line Addendum to the CFW-09 Manual Addendum to the CFW-09 Manual CFW-09HD Line I. GENERAL INFORMATION This addendum has information about the CFW-09HD line
More information