POWER UNITS AND VARIOUS DEVICE

Size: px
Start display at page:

Download "POWER UNITS AND VARIOUS DEVICE"

Transcription

1 SECTI 5A (REV.D) POWER UNITS AND VARIOUS DEVICE Download from Technical Manuals area. SYSTEM POWER UNIT Ref. 08/0 SECTI CTENTS POWER PROTECTI DEVICE 30Vac 4000VA Ref. 33/85 9 DISTRIBUTOR Ref. 08/5 3 SECURITY TRANSFORMER Ref. 9000/30 3 VIDEO SWITCH 4 IN - OUT Ref. 038/69 4 ADDITIAL POWER SUPPLY Ref. 789/ 5 POWER FILTER 30Vac 4000VA Ref. 33/86 9 E AND TWO FAMILY VIDEO KIT 0 MULTIPOLAR WIRE FOR GO! SYSTEMS Ref. 08/90 MULTIPOLAR WIRE FOR CALING MODULES Ref. 08/94 Vdc VOLTAGE ADAPTER FOR SECDARY CAMERA Ref. 840/44 5 CALL REPEATER AUXILIARY RELAY Ref. 788/ 6 SUPPLEMENTARY POWER UNIT Vdc 5Vdc Ref. 090/850 6 LOCK RELEASE TIMER Ref. 03/8 7 RS3 - RS485 INTERFACE Ref. 08/53 7 Some products may be described in the New section. GO! - Technical manual sec.5a

2 3 4 SYSTEM POWER UNIT Ref. 08/0 SYSTEM POWER UNIT Ref. 08/0 75 mm V D E 90 mm 96 mm mm (0 DIN modules) Dedicated GO! system video power unit. Main features include: System power. Data distribution to 5 pairs of terminals. Connection of up to 5 bus lines. Power to apartment stations, one-user video distributors and video or door phone door units. Power to name cards on panel (the number of name cards depends on the system configuration, see System installation and activation ). The risers are identical from a functional point of view so that inputs or outputs can be connected to any one. TECHNICAL SPECIFICATI SYSTEM POWER UNIT Ref. 08/0 TECHNICAL SPECIFICATI - INSTALLATI AND CFIGURATI INSTALLATI AND CFIGURATI The casing is suitable for fitting on DIN bar and wall by means of screws and bolts; in all cases, the power unit must be installed in a dry place where it is sheltered from the elements, respecting the safety standards. Fit the line terminal inside the power unit to simulate the missing spines if not all five spines are used. Line 0 must always be connected. Each dip switch (from to 4) must be switched to the position if the corresponding line is not connected: TC IMPORTANT: Observe the instructions contained in section Installation and activation the system for wiring and maximum distances. 4 3 Power supply: 30Vac ±0% 50Hz 7VA Temperature: -5 C +45 C Humidity: 95% max a 30 C 0 terminals for power and 0 spine bus terminals for power and spine bus terminals for power and spine bus 3 terminals for power and 3 spine bus 4 terminals for power and 4 spine bus sec.5a GO! - Technical manual

3 DISTRIBUTOR Ref. 08/5 TECHNICAL SPECIFICATI SECURITY TRANSFORMER Ref. 9000/30 TECHNICAL SPECIFICATI Ref. 08/5 Ref. 9000/30 DISTRIBUTOR Ref. 08/5 SECURITY TRANSFORMER Ref. 9000/30 V D E mm 4 mm 08/5 PATENTED (IN/OUT) (DER) 39 mm The one-user distributor can be used to distribute the system column bus signal to the indoor station which are therefore connected as extensions. The device has one input (system power unit signal), one passing output (for distribution of signal to other distributors) and one output for connecting indoor station (extensions to video door phones, door phones or special decoding). Up to 3 distributors can be connected in series using the distributor passing output to make systems with 3 apartment stations. TECHNICAL SPECIFICATI 58 mm 83 mm Sch. 9000/30 PRI 54 mm (3 DIN modules) The Urmet Domus Ref. 9000/30 transformer is used to power button module and repertory module name cards at Vac if the maximum load of the system exceeds the capacity of the Ref. 08/0 power unit (see System installation and activation ). DISTRIBUTOR SECURITY TRANSFORMER Temperature: C Uptake: 8 ma IN OUT DER Input signal (input) Output signal (passing) Output signal to extension Important: A jumper which must be removed only if one of the two outputs is disconnected is present on the distributor. The video distributor is provided with the video door phone brackets and has the following codes according to the video door phone model: Utopia Ref. 703/70 Imago Ref. 707/70 Atlantico Ref. 70/70 Signo Ref. 740/70 Artico/Arco Ref. 705/70 Suitable for DIN bar fitting, the device was designed and made in compliance with the laws in force concerning isolation and safety transformers being protected from direct and indirect contact as required by the electrical system standards in force. It carries IMQ marking and respective certifications. The transformer can be used to power up to 8 load units. TECHNICAL SPECIFICATI Power supply: 30Vca 50/60Hz 8VA Secondary: Vca Peak load:,a Protection: With PTC Dissipated power after average working hour:,8w 08/5 PATENTED (IN/OUT) IN/OUT IN/OUT 08/5 PATENTED (DER) (IN/OUT) (DER) IN/OUT 08/5 PATENTED (IN/OUT) (DER) DER DER DER All branches are connected: JUMPER Extension branch cut-off: JUMPER REMOVED Cut-off to column passing output: JUMPER REMOVED Disconnect for 60 to reset after a short-circuit. GO! - Technical manual sec.5a 3

4 VIDEO SWITCH 4 IN - OUT Ref. 038/69 VIDEO SWITCH 4 IN - OUT Ref. 038/69 The Ref. 038/69 video switch can be used to control the auto-on function for one main video door unit camera: The user can select auto-on function on the master door unit (ID=) and switch onto the other cameras connected to the device by pressing the auto-on button on the apartment station. The device is not reset at the end of the display cycle. If a new cycle is started, the camera following the last camera in the previous cycle will be displayed. In addition to the 4 control signals, the device is equipped for this purpose with an input terminal (T) which can be connected to a button for switching the 4 inputs in turn onto the output independently with respect to the control signals (RE, RF, RG and RH). The number of inputs which can be switched in turn by pressing button T can be programmed by means of specific jumpers (from to 4 inputs). A jumper must be connected between RES and 0V terminals if button T is not used. TECHNICAL SPECIFICATI Power voltage (+V, 0V): Uptake: Dimensions (L x W x H): Maximum distance between button contacts and terminals (T, RES, 0V): VIDEO SWITCH 4 IN - OUT Ref. 038/69 TECHNICAL SPECIFICATI 6 5Vcc 0mA 8 x 4 x 5mm R Camera power input (positive) +V Device power input (positive) 0V Device power input (ground) I Coax video signal input - video door phone unit V5 Video signal ground input (sheath) - video door phone unit TC Camera power output - video door phone unit RE Video relay control input - video door phone unit I Coax video signal input - video door phone unit V5 Video signal ground input (sheath) - video door phone unit TC Camera power output - video door phone unit RF Video relay control input - video door phone unit I3 Coax video signal input - video door phone unit 3 V5 Video signal ground input (sheath) - video door phone unit 3 TC3 Camera power output - video door phone unit 3 RG Video relay control input - video door phone unit 3 I4 Coax video signal input - video door phone unit 4 V5 Video signal ground input (sheath) - video door phone unit 4 TC4 Camera power output - video door phone unit 4 RH Video relay control input - video door phone unit 4 I5 Coax video signal input (for cascade connection; de-energised passing through U terminal) V5 Video signal ground input (sheath) U Coax video signal output V5 Video signal ground output (sheath) T Button input 0V Button ground RES Reset input Set the jumper on the device to the position shown in the table according to the number of cameras used: NR. OF JP JP JP3 FUNCTI CAMERAS - - Video signal switch I I Video signal switch I I I (*) Video signal switch I I I3 I4 (*) Factory presetting. 300m 4 sec.5a GO! - Technical manual

5 ADDITIAL POWER SUPPLY Ref. 789/ TECHNICAL SPECIFICATI - Vdc VOLTAGE ADAPTER FOR SECDARY CAMERA Ref. 840/44 INSTALLATI - TECHNICAL SPECIFICATI - WIRING DIAGRAM Ref. 789/ Ref. 840/44 ADDITIAL POWER SUPPLY Ref. 789/ 75 mm 90 mm 96 mm Sch. 789/ 6 mm (7 DIN modules) Power unit Ref. 789/ is used to power additional surveillance cameras in the main calling station. The power supply unit can be installed on a DIN rail, or can be wall mounted using screws and wall plugs. TECHNICAL SPECIFICATI Power supply: 30Vca ± 0% 50/60Hz 8VA Outputs: R 8Vdc out 0,65A int. RL 8Vdc 0,0A V 8Vdc 0,0A Protection: PTC thermistor (*) Temperature: -5 C +45 C Dissipated power after average working hour: 4,W (*) If the PTC thermistor cuts in as a result of overload, cut off mains voltage for at least 60 to reset the unit. Vdc VOLTAGE ADAPTER FOR SECDARY CAMERA Ref. 840/44 75 mm 36 mm ( DIN modules) Sch. 840/44 03 mm The adapter is used to reduce camera power voltage (8Vdc) supplied with power unit Ref. 789/ at a voltage of Vdc. This device can therefore be used to power surveillance CCTV cameras. The casing is made of self-extinguishing ABS plastic. INSTALLATI The device can be installed on the wall with the racket supplied or on a DIN bar. Lever as shown in the figure to access the connection clips. ADDITIAL POWER SUPPLY Vdc VOLTAGE ADAPTER FOR SECDARY CAMERA RL Continuous voltage output (positive) R Continuous voltage output (earth) R IN Rout switch on input (positive) R OUT Monitor supply output (positive) switch on from R IN V Continuous voltage output (positive) 0 } Power voltage input (30Vca) ~30 The connections are made using screw type terminal strips. The maximum cross-section of the wires accepted by the terminal strips is.5mm. TECHNICAL SPECIFICATI Power supply: 8 Vcc Output: Vcc ±% 0,5A continuous 0,3A intermittent 3W max. WIRING DIAGRAM MAINS~ COAX WIRE POWER SUPPLY Ref.789/ R- OUT ADAPTER Ref.840/44 black/white black TV-Camera TVCC GO! - Technical manual sec.5a 5

6 Ref. 788/ Ref. 090/850 CALL REPEATER AUXILIARY RELAY Ref. 788/ INSTALLATI - WIRING DIAGRAM SUPPLEMENTARY POWER UNIT Vdc 5Vdc Ref. 090/850 TECHNICAL SPECIFICATI - INSTALLATI CALL REPEATER AUXILIARY RELAY Ref. 788/ SUPPLEMENTARY POWER UNIT Vdc 5Vdc Ref. 090/850 CALL REPEATER AUXILIARY RELAY SUPPLEMENTARY POWER UNIT Vdc 5Vdc 60 mm Sch. 788/ CH- 0L C NC NA +L + CH+ 50 mm Device Ref. 788/ can be used for the call repeat function. In all other types of systems, simply connect the call signal: in this case, the device will close the relay contact, repeating the call pattern in time. 5 mm Output contacts for resistive load switchover up to A -4V. INSTALLATI The device can be fastened to the wall or to other devices by means of the two holes on the casing tables (screws not provided). 45 mm 63 mm 69 mm 65 mm (4 DIN modules) The Ref. 090/850 power unit supplies voltage at Vdc or 5Vdc. Remove the jumper between terminals P and P to obtain 5Vdc voltage output. The output voltage will be Vdc if the jumper is not removed. TECHNICAL SPECIFICATI Power supply: 30Vca ±0% 50/60Hz 6W Uptake: max 30mA Output: Vout= Vdc 0,8A (with jumper P - P) default Vout= 5 Vdc 0,8A (without jumper P - P) Protection: Thermoprotector PTC (on secondary) (*) Weight: 300g Temperature: -0 C +40 C Sch. 788/ (*) If the PTC thermal cutout is tripped due to overload, cut off mains voltage for at least 60 to reset the power supply unit. INSTALLATI WIRING DIAGRAM S- S+ SV4-038 The connections are made using screw type terminal strips. The maximum cross-section of the wires accepted by the terminal strips is.5 mm. The casing is made of self-extinguishing ABS plastic. The power unit and circuit breaker may be fitted on DIN bar or on wall with two bolts. CALL REPEATER RELAY Ref.788/ +L + CH- 0L CH+ NC C NA ~ CP 30 0 P P Vout Ref.090/850 POWER SUPPLY LOAD 4V=/A Floor call button POWER ~0 } Mains 30Vac ~30 Vout } Vdc or 5Vdc power output P } Jumper connection to change output voltage P 6 sec.5a GO! - Technical manual

7 LOCK RELEASE TIMER Ref. 03/8 TECHNICAL SPECIFICATI RS3 - RS485 INTERFACE Ref. 08/53 TECHNICAL SPECIFICATI Ref. 03/8 Ref. 08/53 LOCK RELEASE TIMER Ref. 03/8 RS3 - RS485 INTERFACE Ref. 08/53 75 mm 90 mm 7 mm (4 DIN modules) The Ref. 03/8 devices are used to time the powering of an electrical lock. Electrical locks can be: Directly activated by capacitance discharge. Activated by capacitance discharge and 50mA hold current. Safety electrical locks. The device can be fastened to the wall or to other devices by means of the two holes on the casing tables (screws not provided). TECHNICAL SPECIFICATI Voltage on +4: 7Vdc Voltage on +/~: 0 5Vdc/ac Continuous current from AP: 5 70mA Timing range: 30 Sec ±0% Temperature: C Max. resistive commutable charge: 0A with 4Vdc 0A with 0Vac Max. voltage for switching: 40Vac/0Vdc Max. resistive commutable power: 400VA with 40Vca 300W with 0Vdc Maximum load at Vdc: 00mA +4 Voltage input 7Vdc +/~ Voltage input 0 5Vdc or 0 5Vac -/ ~ Common wire -/ ~ Common wire SE Timer adjust input; its activation is possible by connecting it to the voltage common wire AP Door release output NO Contact normally open NC C DISPLAY LED LI on: LED LO on: Contact normally closed This one is common for NC/NO, it is normally connected to the voltage common wire input SE is active the relay output is active JUMPERS AND ARRANGEMENTS AR: Possibility of recycle. AMCR: Possibility of connecting the common wire of the relay. TIME: Potentiometer for programming the delay of the activation of the output relay; the max. delay may be obtained by turning the potentiometer clockwise. With jumper AR to NO position: the timer will operate the relay output when external command SE is received only for the time set on the trimmer, regardless of whether the input signal continues or not. With jumper AR in YES position: timer will operate the relay output for the minimum programmed time: the output will remain active if the input signal SE lasts longer than the programmed time. 99 mm,5 mm D(A) D(B) T(A) T(B) 6 D ( A ) D ( B ) T ( A ) T ( B ) G N D 6 R S48 5 PSM-ME-RS3/RS485-P R S 3 Ord.-Nr.: ,6 mm The Ref. 08/53 interface must be used to connect the GO! call module with repertory Ref. 08/3 or Ref. 08/4 to a remote programming device (modem Ref. 08/5 or PC). 4Vdc/ac power terminals 6 4V 0V RS RS485 D(A) D(B) T(A) T(B) 6 Data reception LED on RS3 (RD) 3 LED power supply 4 RS3 line connector 5 RS485 line terminals 6 Data transmission LED on RS3 (TD) TECHNICAL SPECIFICATI Power supply: 4Vdc/ac +/- 0% Uptake: 85mA Temperature: 0 50 C LOCK RELEASE TIMER RS3 - RS485 INTERFACE GO! - Technical manual sec.5a 7

8 RS3 - RS485 INTERFACE Ref. 08/53 INSTALLATI AND CFIGURATI The device is ready for installation on DIN bar. Proceed as follows: Connect RS3 line as shown in the following figure: RS3 - RS485 INTERFACE Ref. 08/53 INSTALLATI AND CFIGURATI DIP SWITCHES Lever with a screwdriver on both sides as shown in the figure to access the converter dip switches: D(A) D(B) T(A) T(B) 6 D ( A ) D ( B ) T ( A ) T ( B ) 6 R S PSM-ME-RS3/RS485-P RS 3 Ord.-Nr.: D(A ) D(B) T(A ) T(B ) D ( A ) D(B ) T ( A) T ( B) G N D 6 R S PSM-ME-RS3/RS485-P R S 3 Ord.-Nr.: The device type dip switch must be set according to the device to be used for programming. DCE (up) for centralised remote programming with modem (default). DTE (down) for local centralised programming via PC. Connect the RS3 line between the programming device and the Ref. 08/53 interface as follows: TxD RxD CTS RTS DTR DSR Max. 5m TxD RxD CTS RTS DTR DSR Line terminal (leave in the position) Device type dip switch DTE Ref. 08/53 Programming device 4V 4V } 4Vdc/ac power supply input 0V 0V } Reference earth for power D(A) D(B) T(A) T(B) Data reception line negative (RS485) connect to terminal A of calling modules Data reception line positive (RS485) connect to terminal B of calling modules Data transmission line negative (RS485) connect to terminal A of calling modules Data transmission line positive (RS485) connect to terminal B of calling modules Do not use Do not use A AWG twisted wire must be used to connect the RS485 line. To terminate the RS485 data line, connect a 50Ω resistor between terminals A and B of the last calling module. Transmission parameter dip switch The transmission parameters must be left in the following positions: DIP DIP DIP 3 DIP 4 DIP 5 DIP 6 DIP 7 DIP 8 8 sec.5a GO! - Technical manual

9 POWER PROTECTI DEVICE 30Vac 4000VA Ref. 33/85 INSTALLATI - TECHINCAL SPECIFICATI - WIRING DIAGRAM POWER FILTER 30Vac 4000VA Ref. 33/86 INSTALLATI - TECHINCAL SPECIFICATI Ref. 33/85 Ref. 33/86 POWER PROTECTI DEVICE 30Vac 4000VA Ref. 33/85 POWER FILTER 30Vac 4000VA Ref. 33/86 03 mm 36 mm ( DIN modules) 90 mm This is a voltage surge varistor power line protection device. The device immediately trips to limit amplitude and preserve the devices installed downstream to the device in the presence of voltage surges generated by atmospheric events.install a power line filter 30V 4000VA Ref. 33/86 downstream to the power protection device to ensure better system operation. Level of protection: as per standard IEC and A: class III with Uoc 6 kv. 03 mm 36 mm ( DIN modules) 90 mm This is a two-cell,high-attenuation,one-phase filter for frequencies >0. MHz active on common and differential mode interference. The device is intended to prevent the propagation of external radiofrequency interference on the power mains which could cause faults in the electrical and electronic devices connected to the mains. Install a power line protection device 30V 4000VA Ref. 33/85 upstream to the power filter to ensure better system operation. POWER PROTECTI DEVICE 30Vac 4000VA POWER FILTER 30Vac 4000VA INSTALLATI The device must be fastened on a DIN bar in a closed electrical panel. Check electrical connections before powering the circuit. Locate the phase wire with a power phase finder connected to terminal, IN side. IMPORTANT The device must be protected by fitting appropriate restricted earthfault protection with current flow equal to 8 A and differential switch with opening current equal to 30mA. The protection device must be connected to earth. Device efficacy will be better at lower earth system resistance. For this reason,the system must comply with standards CEI 64-8/ V edition 0/00 booklet 590. Implement specifications in CEI 64-8/4 edition 0/998 booklet 434 on safety. INSTALLATI The device must be fastened on a DIN bar in a closed electrical panel. Check electrical connections before powering the circuit. Locate the phase wire with a power phase finder connected to terminal, IN side. IMPORTANT The device must be protected by fitting appropriate restricted earthfault protection with current flow equal to 8 A and differential switch with opening current equal to 30mA. The power filter device must be connected to earth.filter efficacy will be better at lower earth system resistance. For this reason, the system must comply with standards CEI 64-8/ V edition 0/00 booklet 590.Implement specifications in CEI 64-8/4 edition 0/998 booklet 434 on safety. TECHINCAL SPECIFICATI Power protection with tripping tension 300 Veff. On two self-extinguishing DIN modules. Nominal voltage: Maximum voltage: Maximum current: Working frequency: Temperature range: WIRING DIAGRAM N L EARTH MAIN~ Ref.33/85 PROTECTI IN Ref.33/86 FILTER = PHASE OUT = NEUTRAL EARTH 30Vac 55Vac 0A 50Hz 4000VA -5 C +40 C N L UTILITY TECHINCAL SPECIFICATI One-phase, two-cell, high-attenuation filter for common and differential interference f >0.Mhz. On two self-extinguishing DIN modules. Nominal voltage: 30Vac Maximum voltage: 55Vac Working frequency: 50Hz Attenuation: 60dB frequency MHz Maximum current: 0A 4000VA Temperature range: -5 C +40 C See power line protection wiring diagram Ref. 33/85. GO! - Technical manual sec.5a 9

10 E AND TWO FAMILY VIDEO KIT SINTHESI DOOR UNIT FRT PANEL REPLACEMENT - E-FAMILY KIT PROGRAMMING KIT WITH VIDEO DOOR PHE ANSWERING SERVICE Ref. 78/56 PROGRAMMING E AND TWO FAMILY VIDEO KIT E AND TWO FAMILY VIDEO KIT The video kits can be used to make basic systems for one- and twofamily users. The kits consist of the following devices: Kit Ref. 78/60 Kit Ref. 78/5 Kit Ref. 78/56 Kit Ref. 78/5 Kit Ref. 78/50 Kit Ref. 78/50 Kit Ref. 78/53 Kit Ref. 78/53 Kit Ref. 78/5 DEVICES GO! system power unit Ref. 08/0 Module holder and frame Ref. 45/6 Flush-mounting box Ref. 45/5 Camera and door unit with buttons Mod. Sinthesi Ref. 08/7 button front frame Ref. 745/07 Camera and door unit with buttons Mod. 8 Ref. 08/0 Video distributor Ref. 08/5 Utopia video door phone Ref. 703/ Bracket for video door phone Utopia Ref. 703/8 Atlantico video door phone Ref. 70/ Bracket for video door phone Atlantico Ref. 70/8 Artico video door phone Ref. 705/ Bracket for video door phone Artico Ref. 705/8 Folio video door phone Ref. 706/ Flush-mounting box for Folio video door phone Ref. 706/60 and plasterboard kit Ref. 706/6 Video door phone answering service Ref. 08/88 Atlantico video door phone Ref. 70/40 Bracket for video door phone Signo Ref. 740/8 Signo video door phone Ref. 740/ Refer to the instructions provided with each component described in the various sections of the manual for installation and programming the video kit. SINTHESI DOOR UNIT FRT PANEL REPLACEMENT For one-family kits with Sinthesi door unit, remove the front panel with buttons from the 08/7 camera unit and insert the button panel Ref. 745/07. Ref. 08/7 Ref. 745/07 E-FAMILY KIT PROGRAMMING Change the user code by shifting switch 5 to the on position on the video door phone bracket. Z CODE 345 INT KIT WITH VIDEO DOOR PHE ANSWERING SERVICE Ref. 78/56 PROGRAMMING Simply set the dip switches on the video door phone and on the power supply to configure the Ref. 78/56 kit. Keep the default settings for all the other devices. VIDEO DOOR PHE Set switch 5 to the position. SYSTEM POWER UNIT Set switch to the position. Z INT CODE 0 sec.5a GO! - Technical manual

11 E AND TWO FAMILY VIDEO KIT E- AND TWO-FAMILY CNECTI KIT DIAGRAM CNECTI DIAGRAM OF KIT WITH VIDEO DOOR PHE ANSWERING SERVICE E- AND TWO-FAMILY CNECTI KIT DIAGRAM CNECTI DIAGRAM OF KIT WITH VIDEO DOOR PHE ANSWERING SERVICE IN/OUT DER E USER DISTRIBUTOR S- S+ CP Only for one family kit 0 S- S+ CP Floor call button CP S+ S- MMS ~ ~0 Video memory module Ref.08/88 Line~ SV Video door phone Mod.Folio Ref.706/ Transformer E AND TWO FAMILY VIDEO KIT 4 Floor call button 3 Ref.08/0 Video power supply (V.004) 4 3 Ref.08/0 VIDEO POWER SUPPLY 0 ILL 0 30 Line~ (V.004) (VX.008) ~ CAMERA MODULE WITH KEYS AND LOUDSPEAKING UNIT ILL TC Lock release SP PA TST V3 V5 T SE- SE+ EXP TC Lock release SP PA TST V3 V5 T SE- SE+ EXP ELECTRIC LOCK ELECTRIC LOCK GO! - Technical manual sec.5a

12 Ref. 08/90 Ref. 08/94 MULTIPOLAR WIRE FOR GO! SYSTEMS Ref. 08/90 MULTIPOLAR WIRE FOR CALING MODULES Ref. 08/94 MULTIPOLAR WIRE FOR GO! SYSTEMS Ref. 08/90 Use of wire Ref. 08/90 is recommended for connecting the various devices in the system to obtain the best system performance. Features of the wire Ref. 08/90 are: Multipolar wire with twisted pair and flameproof PVC outer sheath. Wire cross-section area equal to mm. Pair impedance: 00 Ohm. The wire is provided in 00 metre reels. MULTIPOLAR WIRE FOR CALING MODULES Ref. 08/94 In systems with more than 3 users in which two power units must be connected to the same calling module, the use of a four-wire cable Ref. 08/94 is recommended. The cable consists of two double wires with the following features: Multipolar wire with twisted pairs and flameproof PVC outer sheath. Wire cross-section area equal to mm. Pair impedance: 00 Ohm. The wire is provided in 00 metre reels. MULTIPOLAR WIRE FOR GO! SYSTEMS MULTIPOLAR WIRE FOR CALING MODULES sec.5a GO! - Technical manual

POWER UNITS RELAY DEVICES VARIOUS DEVICES

POWER UNITS RELAY DEVICES VARIOUS DEVICES SECTION 4 (Rev.E) POWER UNITS RELAY DEVICES VARIOUS DEVICES Download from www.urmet.com Technical Manuals area. INTRODUCTION POWER UNITS FOR DIN BAR ASSEMBLY 2 Ref. 786/11-786/12 DOOR PHONE POWER UNIT

More information

PUSH BUTTON PANEL. SECTION 3A (Rev. B) SECTION CONTENTS. Download from Technical Manuals area. sec.3a

PUSH BUTTON PANEL. SECTION 3A (Rev. B) SECTION CONTENTS. Download from  Technical Manuals area. sec.3a SECTION 3A (Rev. B) Download from www.urmet.com Technical Manuals area. SINTHESI 2 CAMERA MODULE AND DOOR UNIT WITH 2 BUTTONS...2 Features...2 Structure...2 Terminals pins description...3 Technical characteristics...3

More information

PSM-ME-RS232/TTY-P Interface converter for RS-232 to TTY transmission systems

PSM-ME-RS232/TTY-P Interface converter for RS-232 to TTY transmission systems Interface converter for RS- to transmission systems. Short Description The rail-mountable and compact interface converters have been designed especially for industrial use in the switch cabinet or switch

More information

WALL MOUNTED PANEL. SECTION 2G (Rev.E) SECTION CONTENTS. Download from Technical Manuals area. sec.2g SMYLE WALL-MOUNTED PANEL 2

WALL MOUNTED PANEL. SECTION 2G (Rev.E) SECTION CONTENTS. Download from   Technical Manuals area. sec.2g SMYLE WALL-MOUNTED PANEL 2 SECTION G (Rev.E) 8 WALL MOUNTED PANEL 8 Download from www.urmet.com Technical Manuals area. SMYLE WALL-MOUNTED PANEL SECTION CONTENTS SPECIAL MODULES...8 TECHNICAL FEATURES... DOOR UNITS... Door phone

More information

2VOICE. Villas and villa compounds Blocks of flats Renewal Residential compounds

2VOICE. Villas and villa compounds Blocks of flats Renewal Residential compounds VOICE Advice for use: Villas and villa compounds Blocks of flats Renewal Residential compounds Two wires throughout for quick and easy installation Renewal using existing wires Maximum flexibility: from

More information

Converter Box Data Sheet

Converter Box Data Sheet Page 1 from 6 Functions of the converter box The converter box is used to adapt physically two interfaces and to separate them galvanicly. It is configured as follows: Two interface slots can be used to

More information

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO Order Number: 8160.UISO Status: V3; 17.09.2010c G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany 1 TABLE OF CONTENTS PLEASE READ BEFORE USE... 3 DESCRIPTION... 5 UMB ISO CONVERTER ISOCON... 6 CONFIGURATION...

More information

ISOLATED RS-232 TO RS-422/485 CONVERTER

ISOLATED RS-232 TO RS-422/485 CONVERTER QUICK START GUIDE ICD400A ISOLATED RS-232 TO RS-422/485 CONVERTER 24/7 TECHNICAL SUPPORT AT 877.877.2269 OR VISIT BLACKBOX.COM STEP 1 - Specifications Complies with FCC Class B and CE requirements. Withstands

More information

} Power ground. Mod ATLANTICO DOOR PHONES. ATLANTICO DOOR PHONES Mod Mod ATLANTICO DOOR PHONES TECHNICAL SPECIFICATIONS

} Power ground. Mod ATLANTICO DOOR PHONES. ATLANTICO DOOR PHONES Mod Mod ATLANTICO DOOR PHONES TECHNICAL SPECIFICATIONS Electronic call Atlantico door phones model 33 are suitable for use in 4+n and + system types. Characteristics of Atlantico door phones are: Innovative, simple, essential design by Michele De Lucchi. Telephone-like

More information

Surge Protection for Surveillance Systems

Surge Protection for Surveillance Systems Surge Protection for Surveillance Systems 1-in-1 Protection for Network Cameras 2-in-1 Protection for Power and Audio/Video Signals 3-in-1 Protection for Power, Audio/Video and PTZ Control Signals Application:

More information

ME778C-RJ45 MAIN MODULE (FRONT CARD) MAIN MODULE. Line: RJ-45. Line: RJ-45 INTERFACE MODULE (REAR CARD) Serial: 10-Pin RJ.

ME778C-RJ45 MAIN MODULE (FRONT CARD) MAIN MODULE. Line: RJ-45. Line: RJ-45 INTERFACE MODULE (REAR CARD) Serial: 10-Pin RJ. ME778C-RJ45 Line: RJ-45 MAIN MODULE Mini Driver MP Card ME778C-RJ45 Power Line: RJ-45 Unit A -TD -RD -CD -TD Serial: 10-Pin RJ INTERFACE MODULE (REAR CARD) Unit B -RD -CD Serial: 10-Pin RJ LO Z A HI Z

More information

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B. Vision OPLC Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V290-19-C30B and V290-19-T40B. General Description Vision OPLCs are programmable

More information

AUDIO AND VIDEO DOOR ENTRY SYSTEM WITH NEXA CODED PANEL

AUDIO AND VIDEO DOOR ENTRY SYSTEM WITH NEXA CODED PANEL AUDIO AND VIDEO DOOR ENTRY SYSTEM WITH NEXA CODED PANEL 2 INTRODUCTION First and foremost we would like to thank you for purchasing this product. Our commitment to satisfying our customers can be seen

More information

Rhino PSM Power Supplies. Operating Instructions

Rhino PSM Power Supplies. Operating Instructions Rhino PSM Power Supplies Operating Instructions RHINO Power Supplies PSM Series Description The PSM power supplies are built-in units. The mounting position for PSM power supplies must fulfill the requirements

More information

EX-RC1 Remote I/O Adapter

EX-RC1 Remote I/O Adapter EX-RC1 Remote I/O Adapter The EX-RC1 interfaces between Unitronics Vision OPLCs and remote I/O Expansion Modules distributed throughout your system. The adapter is connected to a PLC via CANbus. Each adapter

More information

DATA CONNECT ENTERPRISE

DATA CONNECT ENTERPRISE DATA CONNECT ENTERPRISE User s Manual IG202T and IGV23 Modem Document Number 520-01005-001 Rev. A DATA CONNECT Contents Contents... iii Figures... iv Chapter 1 Introduction... 5 Features...6 Applications...7

More information

HID. GE Consumer & Industrial Multilin. High Impedance Differential Module Instruction manual GEK Copyright 2005 GE Multilin

HID. GE Consumer & Industrial Multilin. High Impedance Differential Module Instruction manual GEK Copyright 2005 GE Multilin g GE Consumer & Industrial Multilin HID High Impedance Differential Module Instruction manual GEK-113064 Copyright 2005 GE Multilin GE Multilin 215 Anderson Avenue L6E 1B3 Markham, ON -CANADA T (905) 294

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Vision OPLC V350-35-R34/V350-J-R34 Installation Guide The Unitronics V350-35-R34/V350-J-R34 offers the following onboard I/Os: 22 Digital Inputs, configurable via wiring to include 2 Analog and 3 HSC/Shaft-encoder

More information

ICD105A 1008 page 1/ r001 ICD105A. Industrial RS-232 to RS-422/485 Converter

ICD105A 1008 page 1/ r001 ICD105A. Industrial RS-232 to RS-422/485 Converter ICD105A 1008 page 1/5 7319 r001 ICD105A Industrial RS-232 to RS-422/485 Converter Data Rates up to 115.2 Kbps 10 48 VDC Input Power Range Wide Operating Temperature 3-Way 2000V Optical Isolation Modbus

More information

SED2 Variable Frequency Drives with Electronic (E) Bypass Options

SED2 Variable Frequency Drives with Electronic (E) Bypass Options SED2 Variable Frequency Drives with Electronic (E) Options Description The E- Options are companion packages for the family of SED2 Variable Frequency Drives (s). For information on the family of SED2

More information

EX KVIS RS232/422/485 3-in-1 Serial to USB Adapter (w/ 4KV Isolation, 15KV ESD Surge Protection)

EX KVIS RS232/422/485 3-in-1 Serial to USB Adapter (w/ 4KV Isolation, 15KV ESD Surge Protection) EX-1331-4KVIS RS232/422/485 3-in-1 Serial to USB Adapter (w/ 4KV Isolation, 15KV ESD Surge Protection) 1. Introduction Thank you for purchasing this RS232/422/485 3-in-1 Serial to USB Adapter. It is an

More information

ME758C-RJ45 MAIN MODULE (FRONT CARD) MAIN MODULE. Line: RJ-45 INTERFACE MODULE (REAR CARD) Serial: DB25 RJ45 CONN. INTERFACE MODULE (REAR CARD)

ME758C-RJ45 MAIN MODULE (FRONT CARD) MAIN MODULE. Line: RJ-45 INTERFACE MODULE (REAR CARD) Serial: DB25 RJ45 CONN. INTERFACE MODULE (REAR CARD) ME758C-RJ45 Line: RJ-45 MAIN MODULE Multi- Function LD Card ME758C-RJ45 Power -TD -RD INTERFACE MODULE (REAR CARD) -RTS -CD Serial: DB25 TEST - Remote 511E -ERROR Analog 511 This switch is on the bottom

More information

PGR-6101 MANUAL GROUND-FAULT & INSULATION MONITOR

PGR-6101 MANUAL GROUND-FAULT & INSULATION MONITOR Tel: +1-800-832-3873 E-mail: techline@littelfuse.com www.littelfuse.com PGR-6101 MANUAL GROUND-FAULT & INSULATION MONITOR Revision 0-C-041918 Copyright 2018 by Littelfuse, Inc. All rights reserved. Document

More information

Vision OPLC. General Description. Standard Kit Contents. Installation Guide Vision120. This guide provides basic information for Unitronics Vision120.

Vision OPLC. General Description. Standard Kit Contents. Installation Guide Vision120. This guide provides basic information for Unitronics Vision120. Vision OPLC Installation Guide Vision120 This guide provides basic information for Unitronics Vision120. General Description V120 OPLCs are micro-oplcs, rugged programmable logic controllers that comprise

More information

3710 ACM 3750 PDC 3800 RTU. ISOCOM Communications Card Retrofit Instructions

3710 ACM 3750 PDC 3800 RTU. ISOCOM Communications Card Retrofit Instructions 3710 ACM 3750 PDC 3800 RTU ISOCOM Communications Card Retrofit Instructions Danger During normal operation of this device, hazardous voltages are present which can cause severe injury or death. These

More information

SoundwebTM. Installation Guide

SoundwebTM. Installation Guide 105 SoundwebTM Soundweb TM 9000 Installation Guide Soundweb TM Regulatory Information An example of this equipment has been tested and found to comply with the following European and international Standards

More information

SLX Series. Application Specific Controllers (SLX-ASC-FCU-L, SLX-ASC-HPU-L, SLX-ASC-RTU-L, SLX-ASC-UV-L)

SLX Series. Application Specific Controllers (SLX-ASC-FCU-L, SLX-ASC-HPU-L, SLX-ASC-RTU-L, SLX-ASC-UV-L) SLX Series Document No. 997-1000 Application Specific Controllers (SLX-ASC-FCU-L, SLX-ASC-HPU-L, SLX-ASC-RTU-L, SLX-ASC-UV-L) Free Programmable Controllers (SLX-PC-203, SLX-PC-300, SLX-PC-400, SLX-PC-500

More information

Type MVTT 14 and MVTT 15: Static Digital Time delay relays

Type MVTT 14 and MVTT 15: Static Digital Time delay relays Type MVTT 4 and MVTT 5: Static Digital Time delay relays Features 000/ setting range Time settings easily selected by means of thumbwheel switches Provide time delayed pick-up, or drop-off Compact construction

More information

02/11/2015

02/11/2015 DIN Rail Mount 22.5 mm ETM2 Part number 84874023 Version ETM : Controls temperature of machines using built-in PTC probes Line break or probe short-circuit detection Version ETM2 / ETM22 : Fault latching

More information

Installing Your 1394 Drive Interface Module

Installing Your 1394 Drive Interface Module Installation Instructions Installing Your Drive Interface Module (Catalog Number -DIM) Introduction This publication provides installation instructions for adding the Drive Interface Module to your system.

More information

Koppelmodul (HART--Modem) für SIMATIC PDM Interface (HART modem) for SIMATIC PDM

Koppelmodul (HART--Modem) für SIMATIC PDM Interface (HART modem) for SIMATIC PDM Koppelmodul (HART--Modem) für SIMATIC PDM Interface (HART modem) for SIMATIC PDM 7MF4997--1DA Ausgabe Februar 2002 Edition February 2002 C73000--B7164--C170--2 1 /16 Koppelmodul für SIMATIC PDM Interface

More information

22 Digital Inputs, including 2 Analog, 2 HSC/Shaft-encoder inputs 16 Transistor Outputs

22 Digital Inputs, including 2 Analog, 2 HSC/Shaft-encoder inputs 16 Transistor Outputs Vision PLC+HMI V130-33-T38/V130-J-T38 V350-35-T38/V350-J-T38 V430-J-T38 Installation Guide 22 Digital Inputs, including 2 Analog, 2 HSC/Shaft-encoder inputs 16 Transistor Outputs General Description All

More information

MD9 MULTIDROP INTERFACE INSTRUCTION MANUAL

MD9 MULTIDROP INTERFACE INSTRUCTION MANUAL MD9 MULTIDROP INTERFACE INSTRUCTION MANUAL REVISION: 01/05/03 COPYRIGHT (c) 1987-2003 CAMPBELL SCIENTIFIC, INC. This is a blank page. WARRANTY AND ASSISTANCE The MD9 MULTIDROP INTERFACE is warranted by

More information

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

See instructions to download and install the latest version of LinkBoxMB and the user's manual at Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any

More information

Manual Fiber Optic Interfaces

Manual Fiber Optic Interfaces Manual Fiber Optic Interfaces Type 81210, 81211 61210, 61211 65210, 65211 41210 Release 1.4 Subject to error and alteration 31 06/2007 by Wiesemann & Theis GmbH Subject to error and alteration: Since it

More information

24/48/120 VAC Interface Card Instruction Manual

24/48/120 VAC Interface Card Instruction Manual 24/48/120 VAC Interface Card Instruction Manual Distributed by Ergonomic Partners Sales@ErgonomicPartners.com www.ergonomicpartners.com Tel: (314) 884-8884 April 2012 Part Number: -R2 Copyright 2012 Magnetek

More information

PGR-4700 MANUAL SENSITIVE GROUND-FAULT RELAY

PGR-4700 MANUAL SENSITIVE GROUND-FAULT RELAY Tel: +1-800-832-3873 E-mail: techline@littelfuse.com www.littelfuse.com/pgr-4700 PGR-4700 MANUAL SENSITIVE GROUND-FAULT RELAY REVISION 2-B-032218 Copyright 2018 by Littelfuse, Inc. All rights reserved.

More information

PGR-6100 MANUAL GROUND-FAULT & INSULATION MONITOR

PGR-6100 MANUAL GROUND-FAULT & INSULATION MONITOR Tel: +1-800-832-3873 E-mail: techline@littelfuse.com www.littelfuse.com/pgr-6100 PGR-6100 MANUAL GROUND-FAULT & INSULATION MONITOR Revision 2-C-050818 Copyright 2018 Littelfuse All rights reserved. Document

More information

2U Congestion Alert Rack Insert for UK

2U Congestion Alert Rack Insert for UK 2U Congestion Alert Rack Insert for UK 2U Congestion Alert Rack Insert for UK The 2U congestion alert rack insert comes fully assembled, wired and ready to be installed in a rack. The rack provides communications,

More information

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Rhino Buffer Module PSM24-BFM600S. Operating Instructions Rhino Buffer Module PSM24-BFM600S Operating Instructions RHINO BUFFER MODULE PSM24-BFM600S Description The PSM24-BFM600S Buffer Module will hold the output voltage of a 24 VDC power supply after brownouts

More information

24 Input/8 Output AC Block I/O Module

24 Input/8 Output AC Block I/O Module 4 Input/8 Output AC Module Cat. No. 79-4A8 Series B Installation Mount the block I/O module in a vertical (recommended) or horizontal position. Allow sufficient room around the block for cooling air to

More information

PGR-2601 MANUAL DC GROUND-FAULT RELAY

PGR-2601 MANUAL DC GROUND-FAULT RELAY POWR-GARD Ungrounded DC System PGR-2601 SERIES DC Ground-Fault Relay PGR-2601 MANUAL DC GROUND-FAULT RELAY AUGUST 31, 2009 REVISION 1 POWR-GARD DC GROUND-FAULT RELAY PWR TRIP 5 4 3 2 6 - BUS 8 10 15 20

More information

SED2 Variable Frequency Drives Conventional Bypass (C-Bypass) Options

SED2 Variable Frequency Drives Conventional Bypass (C-Bypass) Options Submittal Sheet SED2 Variable Frequency Drives Conventional Bypass (C-Bypass) Options Description The Bypass Options are companion packages for the family of SED2 Variable Frequency Drives. For information

More information

Vision OPLC V TR6/V350-J-TR6

Vision OPLC V TR6/V350-J-TR6 Vision OPLC V350-35-TR6/V350-J-TR6 Installation Guide The Unitronics V350-35-TR6/V350-J-TR6 offers the following onboard I/Os: 8 Digital Inputs, configurable via wiring to include 2 Analog (current/voltage)

More information

Installing the DX LCD Display

Installing the DX LCD Display DX LCD Display User s Guide 3-1 Chapter 3 Installing the DX LCD Display Introduction Use the DX LCD Display as either a portable device, or permanently mount it in a panel or on the wall. For panel and

More information

Manual Industry Interfaces

Manual Industry Interfaces Manual Industry Interfaces W&T Release. Type 0, 0 0, 00 0, 0 0, 0 Industry Interfaces 0/0 by Wiesemann & Theis GmbH Subject to errors and changes: Since we can make mistakes, none of our statements should

More information

MINI-PS AC/10-15DC/8

MINI-PS AC/10-15DC/8 Primary-Switched Power Supply, Narrow Design Data Sheet 08/2004 MINI POWER provides: An extra narrow design, with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a

More information

ADAM-4510 RS-422/RS-485 Repeater ADAM-4510S Isolated RS-422/485 Repeater ADAM-4520 Isolated RS-422/485 Converter Startup Manual

ADAM-4510 RS-422/RS-485 Repeater ADAM-4510S Isolated RS-422/485 Repeater ADAM-4520 Isolated RS-422/485 Converter Startup Manual ADAM-510 RS-/RS-85 Repeater ADAM-510S Isolated RS-/85 Repeater ADAM-50 Isolated RS-/85 Converter Startup Manual Packing List Before you begin installing your module, please make sure that the following

More information

ICD200A Quick Start Guide. Convert RS-232 data signals to RS-422/485 signals in heavy industrial areas.

ICD200A Quick Start Guide. Convert RS-232 data signals to RS-422/485 signals in heavy industrial areas. Industrial Opto-Isolated RS-232 to RS-422/485 Converter Convert RS-232 data signals to RS-422/485 signals in heavy industrial areas. Rugged IP30-rated metal case for panel mounting. Quick Start Guide Customer

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Vision OPLC V130 COM Modules: V100-17-CAN, V100-17-RS4/X, V100-17-ET2 This guide shows you how to install an additional communication module in a V130 controller. Instructions and technical specifications

More information

ASTAT XB/XBm Remote Operator

ASTAT XB/XBm Remote Operator ASTAT XB/XBm Remote Operator User Manual 1 Introduction 1.1 Important User Information Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery

More information

Installation Manual for D155X Series of 12V Switched Mode Power Supply for Access Control

Installation Manual for D155X Series of 12V Switched Mode Power Supply for Access Control Installation Manual for D155X Series of 12V Switched Mode Power Supply for Access Control D1551A D1551B D1551P D1553B D1553C D1553P D1555B D1555C D1555P D155X Series Part Numbers 1A 12 volts in A box 1A

More information

Series AME25-JZ 25 Watt AC-DC / DC-DC Converter

Series AME25-JZ 25 Watt AC-DC / DC-DC Converter FEATURES: Click on Series name for product info on aimtec.com Series AME-JZ I/O Isolation 000VAC Low Ripple and Noise Operating Temp: -0 C to +70 C Over Voltage Protection Over current Protection Up to

More information

8000 Sports Scoreboards

8000 Sports Scoreboards 8000 Sports Scoreboards Installation manual www.bodet-sport.com Bodet Sport 1 rue du Général de Gaulle 49340 Trémentines I FRANCE Tel: +33 (0) 2 41 71 72 00 Fax: +33 (0) 2 41 71 72 01 Ref: 608080 F Ensure

More information

EXPANSION PERIPHERAL CVM-R10 C. (Code ) INSTRUCTION MANUAL ( M / 00 A ) (c) CIRCUTOR S.A.

EXPANSION PERIPHERAL CVM-R10 C. (Code ) INSTRUCTION MANUAL ( M / 00 A ) (c) CIRCUTOR S.A. EXPANSION PERIPHERAL CVM-R10 C (Code 7 70 217 ) INSTRUCTION MANUAL ( M 981 170 / 00 A ) (c) CIRCUTOR S.A. ------ CVM-R10 C Peripheral --------------- Pag. 1 CVM-R10C EXPANSION PERIPHERAL 1.- DESCRIPTION

More information

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any

More information

2C138. Sensitive Earth Fault Relay. Features. Application. Operation

2C138. Sensitive Earth Fault Relay. Features. Application. Operation Technical Bulletin 2C138 Sensitive Earth Fault Relay Features High sensitivity (0.1% of I n ) 2 nd & 3rd harmonic & HF noise suppression - tuned to 50 Hz Optional reset functions Instantaneous (Fast),

More information

1 Description. 2 Specifications. Product Installation Document. Honeywell 12 Clintonville Road Northford, CT

1 Description. 2 Specifications. Product Installation Document. Honeywell 12 Clintonville Road Northford, CT Honeywell 12 Clintonville Road Northford, CT 06472 http://www.honeywellpower.com HP600ULACM4CB HP600ULACM8CB Access Control Power Supply/Charger with Power Distribution Controller PN 52395:A 1/05/06 ECN

More information

Serial/Ethernet Converter

Serial/Ethernet Converter Serial/Ethernet Converter IE-CS-2TX-1RS232/485 IE-CST-2TX-1RS232/485 IE-CS-2TX-2RS232/485 IE-CST-2TX-2RS232/485 Hardware Installation Guide Second Edition, August 2016 1243440000/01/08.16 Please note:

More information

OPTIMISED LUMINAIRE PROTECTION

OPTIMISED LUMINAIRE PROTECTION OPTIMISED LUMINAIRE PROTECTION LUMINAIRE PROTECTION AND POWER ADJUSTMENT This chapter presents inrush current limiters, electronic components to protect luminaires against mains surges, power reduction

More information

See instructions to download and install the latest version of LinkBoxLON and the user's manual at

See instructions to download and install the latest version of LinkBoxLON and the user's manual at Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any

More information

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

See instructions to download and install the latest version of LinkBoxMB and the user's manual at Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any

More information

SINETAMER. ESPECIFIACIONES EQUIPOS COMERCIALIZADOS POR EDC SUPPLY y RESPALDADOS POR EDCEECA EN VENEZUELA

SINETAMER. ESPECIFIACIONES EQUIPOS COMERCIALIZADOS POR EDC SUPPLY y RESPALDADOS POR EDCEECA EN VENEZUELA SINETAMER. ESPECIFIACIONES EQUIPOS COMERCIALIZADOS POR EDC SUPPLY y RESPALDADOS POR EDCEECA EN VENEZUELA SUPRESOR PRINCIPAL DE 300 KA. ST-SMLA 3N4 TRANSIENT VOLTAGE SURGE SUPPRESSORS. PROTECTION AGAINST

More information

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B. Vision OPLC Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V290-19-C30B and V290-19-T40B. General Description Vision OPLCs are programmable

More information

Moxa TCC-100 Series User s Guide

Moxa TCC-100 Series User s Guide Moxa TCC-100 Series User s Guide Eighth Edition, February 2009 www.moxa.com/product 2009 Moxa Inc. All rights reserved. Reproduction without permission is prohibited. Moxa TCC-100 Series User s Guide The

More information

EasySync Ltd. ES-R-2x01-M RS232 to RS422 / RS485 Converter. User Guide. Document Reference No.: ES_ Version draft Issue Date:

EasySync Ltd. ES-R-2x01-M RS232 to RS422 / RS485 Converter. User Guide. Document Reference No.: ES_ Version draft Issue Date: EasySync Ltd ES-R-2x01-M RS232 to RS422 / RS485 Converter User Guide Document Reference No.: ES_000011 Issue Date: 2009-04-10 The ES-R-2001-M and ES-R-2101-M provide a simple method of converting RS232

More information

OHIO SEMITRONICS, INC. AC MULTIFUNCTION PROGRAMMABLE TRANSDUCERS & -1000L

OHIO SEMITRONICS, INC. AC MULTIFUNCTION PROGRAMMABLE TRANSDUCERS & -1000L AC PROGRAMMABLE TRANSDUCERS MODBUS OR LONWORKS DESCRIPTION The DMT-1000 is a programmable transducer with an RS-485 bus interface (MODBUS ). It supervises several variables of a poly-phase electrical power

More information

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

See instructions to download and install the latest version of LinkBoxMB and the user's manual at Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any

More information

MINI MCR-SL-PT100-UI-200

MINI MCR-SL-PT100-UI-200 Configurable temperature transducer for PT00 INTERFACE Data sheet 078_en_0 PHOENIX CONTACT 00-0-5 Description The MINI MCR-SL-PT00-UI-00... is a configurable -way isolated temperature transducer. It is

More information

Miniature Asynchronous 4-Wire High Speed Modems

Miniature Asynchronous 4-Wire High Speed Modems ME1862A-F ME1863A-F JULY 2003 ME1862A-M ME1863A-M Miniature Asynchronous 4-Wire High Speed Modems CUSTOMER SUPPORT INFORMATION Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500)

More information

USER MANUAL MODEL 2017P MODEL 2017P60. RS-232 to 20mA and. RS-232 to 60mA Current Loop Converters

USER MANUAL MODEL 2017P MODEL 2017P60. RS-232 to 20mA and. RS-232 to 60mA Current Loop Converters USER MANUAL MODEL 2017P RS-232 to 20mA and MODEL 2017P60 RS-232 to 60mA Current Loop Converters 07M2017P-E Doc# 073051UE Revised 5/7/96 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 1.0

More information

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064 Monitoring technique VARIMETER Voltage relay MK 9064N, MH 9064 0269462 Your Advantages Preventive maintenance For better productivity Quicker fault locating Precise and reliable Min-, Max. value or window

More information

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

See instructions to download and install the latest version of LinkBoxMB and the user's manual at Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any

More information

Advanced Visual Solutions Ltd

Advanced Visual Solutions Ltd Advanced Visual Solutions Ltd Unit 2, Eastman Way Hemel Hempstead, Hertfordshire HP2 7DU Telephone : ( 01442 ) 252280 Fax : ( 01442 ) 244578 Email : visionservices@btclick.com : Website : www.avsl.com

More information

Product data sheet accessories control and regulation Accessories AIRWIN

Product data sheet accessories control and regulation Accessories AIRWIN Product data sheet accessories control and regulation BO-CT1 Continuous controller Item no. 6100101 Control of humidification performance BO-CT1 Option board 2 binary inputs Item no. 002212 Setpoint switching,

More information

W&T. Universal Fiber Optic Interface Converter W&T. Manual. Universal FO Interface Converter. Model Release 1.0. Subject to error and alteration

W&T. Universal Fiber Optic Interface Converter W&T. Manual. Universal FO Interface Converter. Model Release 1.0. Subject to error and alteration Manual Universal FO Interface Converter Model 81215 Release 1.0 Subject to error and alteration 13 10/2012 by Wiesemann & Theis GmbH Subject to error and alteration: Since it is possible that we make mistakes,

More information

LED55WPG Programmable LED Driver

LED55WPG Programmable LED Driver Dimmable Constant Current Rev 8-9-7 Electrical Specifications Input Voltage Range: Frequency: Power Factor: Inrush Current: Input Current (Max): -77 Vac Nom. (8-35 V Min/Max) 5/6 Hz Nom. (47-63 Hz Min/Max)

More information

CA-A480-A Elevator Controller. Reference & Installation Manual

CA-A480-A Elevator Controller. Reference & Installation Manual CA-A480-A Elevator Controller Reference & Installation Manual TABLE OF CONTENTS INTRODUCTION.................................................................. 4 Introduction.............................................................................................

More information

The PM1000 series is a universal 4 digit LED plug-on display for transmitters with 4-20mA 2 wire output and fitted with DIN43650 connector.

The PM1000 series is a universal 4 digit LED plug-on display for transmitters with 4-20mA 2 wire output and fitted with DIN43650 connector. PM1000 SERIES PLUG-ON DISPLAY BRIGHT LED DISPLAY INDICATION RANGE -999 TO +9999 FITS TO DIN 43650 CONNECTOR PLUG-ON TO ANY TRANSMITTER WITH 4-20MA OUTPUT EASY TO SCALE ON SITE ROBUST DESIGN SET POINT OPTION

More information

MIC-2 MKII, Multi-instrument DATA SHEET

MIC-2 MKII, Multi-instrument DATA SHEET MIC-2 MKII, Multi-instrument DATA SHEET Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional)

More information

MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE

MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE INSTALLATION INSTRUCTIONS Revision B1 Rapid City, SD, USA, 05/2009 MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE BE SURE POWER IS DISCONNECTED PRIOR TO INSTALLATION! FOLLOW NATIONAL, STATE AND LOCAL CODES.

More information

5.1. Motor Protection and Monitoring. Contents. Product Overview. Monitoring Relays. D64R Series Digital Ground Fault Relays...

5.1. Motor Protection and Monitoring. Contents. Product Overview. Monitoring Relays. D64R Series Digital Ground Fault Relays... .1 Ground Fault Relays and Monitors Contents Description Current.................. Phase................... Voltage.................. Ground Fault Relays and Monitors D64R Series Digital Ground Fault Relays....

More information

General Description V TR34/V130-J-TR34 V TR34/V350-J-TR34 V430J-R34 V R34/V130-J-R34 V R34/V350-J-R34

General Description V TR34/V130-J-TR34 V TR34/V350-J-TR34 V430J-R34 V R34/V130-J-R34 V R34/V350-J-R34 Vision OPLC V130-33-TR34/V130-J-TR34 V350-35-TR34/V350-J-TR34 V430-J-TR34 V130-33-R34/V130-J-R34 V350-35-R34/V350-J-R34 V430-J-R34 Installation Guide 22 Digital Inputs, including 3 HSC/Shaft-encoder Inputs,

More information

CANBUS Connector Rx and Tx LED to indicate that communication is active Closed circuit terminal (Term) LAN serial port connector

CANBUS Connector Rx and Tx LED to indicate that communication is active Closed circuit terminal (Term) LAN serial port connector 4.4 IPEX60D 4.4.1 Description of the connections Connector Description Connector for 24Vac/dc power supply Analogue inputs (Pb1 - Pb5, PbC) Potential free digital inputs (DI1 - DI3, DIC) Additional power

More information

PTC/PT100 board 2.0 Option

PTC/PT100 board 2.0 Option PTC/PT100 board 2.0 Option Instruction Manual - English PTC/PT100 board 2.0 Option Instruction Manual - English Document number: 01-3873-01 Edition: r1 Date of release: 2006-10-30 Copyright Emotron AB

More information

XT-9100 Technical Bulletin

XT-9100 Technical Bulletin System 9100 Technical Manual 636.4 Technical Bulletins Section Technical Bulletin Issue Date 0896 XT-9100 Technical Bulletin XT-9100 Extension Module/XP-910x Expansion Modules Page 3 Introduction 3 SX

More information

MT G (Rev. January 2011)

MT G (Rev. January 2011) INDEX INDEX http://www.urmetdomus.com e-mail:info@urmetdomus.it MT 124-012G (Rev. January 2011) INDEX INDEX This technical manual is released by Urmet Domus ST/UTI II INDEX SYSTEM Sec. 1 CALL MODULE INDEX

More information

PSM-ME-RS485/RS485-P. Repeater for RS wire bus systems. Data sheet. 1 Description

PSM-ME-RS485/RS485-P. Repeater for RS wire bus systems. Data sheet. 1 Description Repeater for RS-485 2-wire bus systems Data sheet 100273_en_06 PHOENIX CONTACT 2016-09-09 1 Description The PSM-ME-RS485/RS485-P RS-485 repeater was developed for the high requirements of fieldbus systems.

More information

Compact Coded Magnetic Safety Interlock Switch and Control Units

Compact Coded Magnetic Safety Interlock Switch and Control Units C Conforms to EN292, EN60204-1, EN954-1, EN1088, EN60947-5-3, EN947-5-3, EN50081, EN50082, EN61000-6-2 UL and C-UL listed, TUV certified Description R US Compact Coded Magnetic Safety Interlock Switch

More information

OPTIMISED LUMINAIRE PROTECTION

OPTIMISED LUMINAIRE PROTECTION OPTIMISED LUMINAIRE PROTECTION LUMINAIRE PROTECTION AND POWER ADJUSTMENT This chapter presents inrush current limiters, electronic components to protect luminaires against mains surges, power reduction

More information

Installation & Configuration manual. InduBox GSM IV

Installation & Configuration manual. InduBox GSM IV Installation & Configuration manual InduBox GSM IV 2008 / 02 / 19 2 ! CAUTION! ELECTRIC SHOCK HAZARD IF COVER REMOVED SERVICE BY QUALIFIED PERSONEL ONLY Document History Date Version Auteur 02/10/2006

More information

Cardax FT Controller 3000

Cardax FT Controller 3000 Installation Note Cardax FT Controller 000 CAUTION This equipment contains components that can be damaged by electrostatic discharge. Ensure both you and the equipment are earthed before beginning any

More information

Junos WebApp Secure 5.0 Hardware Guide

Junos WebApp Secure 5.0 Hardware Guide Junos WebApp Secure 5.0 Hardware Guide Junos WebApp Secure 5.0 Hardware Guide This document contains a specification for the MWS1000 hardware appliance, as well as instructions for installation into a

More information

User Guide. Westermo Teleindustri AB TD-29 DC. FSK-modem Multidrop 2-wire.

User Guide. Westermo Teleindustri AB TD-29 DC. FSK-modem Multidrop 2-wire. User Guide 6611-2002 TD-29 DC Westermo Teleindustri AB FSK-modem Multidrop 2-wire www.westermo.com Legal information The contents of this document are provided as is. Except as required by applicable law,

More information

PSC-AC. PSC AC-series W 1 to 3 Outputs. AC-DC Power supply. Input Voltage ranges. Single output ratings. 2-3 outputs ratings

PSC-AC. PSC AC-series W 1 to 3 Outputs. AC-DC Power supply. Input Voltage ranges. Single output ratings. 2-3 outputs ratings PSC-AC AC-DC Power supply PSC AC-series 100-240W 1 to 3 Outputs Input / Output Wide input voltage ranges. Single outputs from 5 to 48 V. Two to three outputs 5 to 24 V. Operation High efficiency Operating

More information

2100-IS RS232 to RS422\485 Converter.

2100-IS RS232 to RS422\485 Converter. to RS\8 Converter. Converts and Isolates from a computer to RS or RS8 for communication to a field Datalogging system. REGI STERED ISO001 S U P P I L R E 1 TECHNOLOGY & QUALITY AWARD Features. l Audible

More information

H704-42(H)(E), H704-42/1(H)(E)

H704-42(H)(E), H704-42/1(H)(E) POWER MONITORING INSTALLATION GUIDE H704-42(H)(E), H704-42/1(H)(E) Branch Current Monitor DANGER NOTICE Installer's Specifications General: Operating Temp. Range 0 to 60 C (32 to 140 F) (

More information

AGATA C200 UK A/200N TARGHA 200. Installation Manual AGATAKIT C 200 UK

AGATA C200 UK A/200N TARGHA 200. Installation Manual AGATAKIT C 200 UK TARGHA 200 A/200N AGATA C200 UK Installation Manual AGATAKIT C 200 UK 24806770/28-05-2013 AGK200C03UK HPC/1 AGATA C200 UK AG2K200C03UK HPC/2 HA/200 HBP AG3K200C03UK HPC/3 A/200N AGK200C03HNA HPC/1+HNA

More information

STEP-PS/1AC/24DC/1.75

STEP-PS/1AC/24DC/1.75 Primary-switched power supply, 1 AC, output current 1.75 A INTERFACE Data Sheet 103506_en_00 1 Description PHOENIX CONTACT - 05/2008 Features STEP POWER power supply units for building automation The new

More information

MGate 5105-MB-EIP Quick Installation Guide

MGate 5105-MB-EIP Quick Installation Guide MGate 5105-MB-EIP Quick Installation Guide Edition 2.2, March 2019 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777 Fax: 1-714-528-6778

More information