Sensorsoft. Sensorsoft Power Sensor User Manual. Model SP6400J. Manual P/N Rev 5 October 24, 2014
|
|
- Blake Ball
- 5 years ago
- Views:
Transcription
1 Sensorsoft Sensorsoft Power Sensor User Manual Model SP6400J Manual P/N Rev 5 October 24, 2014 Copyright Sensorsoft Corporation, All rights reserved. Sensorsoft and Soft Power Sensor are trademarks of Sensorsoft Corporation.
2
3 Table of Contents Overview... 4 About this Manual... 4 Installing the Sensorsoft Power Sensor... 5 Choosing a Location for Installation... 5 Connecting the Sensorsoft Power Sensor to a serial port... 5 SP6400J Sensorsoft Power Sensor Specifications... 6 Making communication cables for J-Suffix Sensorsoft Devices... 7 Writing programs for the Sensorsoft Power Sensor Sending commands to the Sensorsoft Power Sensor Receiving responses from the Sensorsoft Power Sensor Reading the Sensorsoft ID Record Getting Help Limited Warranty Technical Support Day Money Back Guarantee Returns... 15
4 Overview The SP6400J Sensorsoft Power Sensor is an RS232 compatible serial device based on the Sensorsoft Device Protocol. The SP6400J is intended for applications where the customer needs to be immediately informed of the loss or availability of AC power source. The SP6400J detects the loss or availability of AC power source using an AC-DC power adapter connected to its 2.1 mm power detector jack. The SP6400J provides a boolean state output indicating POWER FAIL or POWER OK. The SP6400J monitors the voltage level on its 2.1 mm power detector jack using a threshold comparator. Using an external AC-DC power adapter, the SP6400J, can detect a power failure when AC line voltage drops to 50 percent of the normal line voltage. See specifications in this document for appropriate AC-DC power adapters to use with this device. Sensorsoft Devices offer the following features and benefits over other RS232 serial devices: Powered from the serial port (no external power or battery required) CRC error detection (detects transmission errors and improves reliability) Virtually unlimited cable lengths (1000 ft) Plug and go operation (little or no user configuration required) About this Manual The Sensorsoft Power Sensor may also be referred to as a Soft Power Sensor, Power Sensor, Sensorsoft device or SSD (Sensorsoft Soft Device) throughout this manual. When other sections of this manual are referenced, italics are used. 4
5 Installing the Sensorsoft Power Sensor Installation of the Sensorsoft Power Sensor is composed of the following: Choosing a Location for Installation Connecting the Sensorsoft Power Sensor to a serial port Starting the Sensorsoft software. Please refer to the specific software manual that applies to your installation. Choosing a Location for Installation Locate the Power Sensor within 6 feet (2 m) of the AC power source you are monitoring. Please also keep the following points in mind: The Power Sensor can only be powered from the serial port through its RJ45 modular connector. The 2.1 mm power jack is for AC power detection only. The computer or device server where you connect the Power Sensor must always be backed up by a UPS (Uninterruptible Power Supply) in order for it to detect AC power loss. Connecting the Sensorsoft Power Sensor to a serial port Use the appropriate C200X cable to connect the Power Sensor to your computer or device server. Please refer to the Sensorsoft price list for the available types of cables. Plug the AC plug of the AC-DC power adapter into the AC power source outlet that you wish to monitor. Plug DC plug (2.1 mm) of the AC-DC power adapter into the power jack of the Power Sensor. If you intend to make your own custom cable for a J-Suffix Sensorsoft device, please refer to Making communication cables for J-Suffix Sensorsoft Devices. If you are connecting the Power Sensor to a device server please be sure to configure the port as follows: 1200 bps, 8 bits, no parity, 1 stop bit Turn off autobaud Flow control set to none Non-telnet binary (raw) transfer mode Assert RTS and DTR always Refer to your device server documentation for more details on the above. Note the physical port number where you plugged the cable into your computer or device server. If the Power Sensor is being plugged into a Windows based computer that has only one COM port, the port number is usually COM1. 5
6 SP6400J Sensorsoft Power Sensor Specifications Detection Capabilities: Can detect availability or loss of AC power source with boolean state output (PWR_FAIL/PWR_OK). Maximum measurement rate: one reading every second Housing Dimensions: 8 cm (3.1") x 4 cm (1.6") x 2 cm (0.8") Housing Material: injection molded ABS thermoplastic Housing Colour: light gray Communications connector: 8 position modular jack, (accepts 8 position plug RJ45) Power source: Port-powered (RTS and DTR, both asserted) Power supply current drain: < 10 ma Power detector connector: 2.1 mm power jack, accepts plug from AC-DC power adapters such as P/N PA6109, PA6209 or similar. The minimum voltage on this jack must be 7.8 volts DC for a PWR_OK reading. A voltage below this would give a PWR_FAIL reading. Power detector method: threshold voltage comparator Operating temperature range: 0 º C to +60 º C (32 º F to +140 º F) Communications Interface: RS232C using TX,RX,RTS,DTR and GND. One device per serial port. Maximum communications cable length: 305 m (1000 ft.) using recommended cable type. Low capacitance shielded cable or UTP is recommended. Communications Protocol: Sensorsoft Device Protocol, Version 2.0 Error control: 16 bit CRC (cyclic redundancy checking) for detection of communication errors between the device and host computer. 6
7 Making communication cables for J-Suffix Sensorsoft Devices In some applications it is not possible to use pre-assembled cables. When installing the Sensorsoft Power Sensor at a remote location it may be necessary to run cables through walls, ceiling or conduits where connectors would get jammed. In this situation it makes sense to run the cables and then terminate them, on-site, using hand tools. Further, if your host serial port is of the DCE type (some multi-port serial cards) it will be necessary to make your own cables. The following details will assist you in doing that. A properly made cable will allow your Sensorsoft device to operate reliably over long cable lengths up to 305 m (1000 ft) long. The Sensorsoft device modular jack connector uses the same UTP wire map as 10-BASE-T and ISDN. It is therefore possible to use this type of cabling system for Sensorsoft devices. PIN-OUT OF THE MODULAR 8 POSITION JACK/PLUG ON A SENSORSOFT DEVICE Note: Terminal No. 1 is the terminal to the extreme left as you face the cable opening, latch tab down. Terminal Function UTP wire color (solid-tracer) 1 ST Receive Data white-green 2 Ground green 3 ST Transmit Data white-orange 4 Power +V blue 5 Ground white-blue 6 Ground orange 7 Power +V white-brown 8 Ground brown The following are suggested specialized tools and parts needed to make good quality cables: Hand Tools: AMP Crimping Tool P/N or , for modular plugs AMP 8 position modular die set P/N AMP Crimping Tool P/N or , for subminiature D pin or socket contacts AMP PROCRIMPER P/N , for subminiature D pin or socket contacts AMP Insertion/Extraction Tool P/N , for subminiature D connector contacts Materials: Berk-Tek UTP (Unshielded Twisted Pair) round stranded cable, P/N TP (4 pair, 8-#24 AWG wires, category 4 or better, 75 C) AMP 8 position modular plug for round stranded wire cables, P/N (CAT4) AMP 8 position modular plug for round stranded wire cables, P/N (CAT5) AMP DB-9 receptacle subminiature D connector (crimp-snap-in), P/N or -3 AMP DB-25 receptacle subminiature D connector (crimp-snap-in), P/N or AMP socket crimp contact for subminiature D connectors, P/N AMP pin crimp contact for subminiature D connectors, P/N
8 Cable P/N C pin Serial Port to Sensorsoft Device DB-9F to RJ45 modular plug 9 pin Port Sensorsoft Device 3 TX white-green RX 1 2 RX white-orange TX 3 4 DTR white-brown POWER +V 7 7 RTS blue POWER +V 4 5 SIGNAL GND green GND 2 P/N C2000 is for use with PC s and most other devices which have a 9 position serial port. F indicates female/socket type connector. Cable P/N C2001 and C2002 DTE Serial Port to Sensorsoft Device DB-25 to RJ45 modular plug DTE Port Sensorsoft Device 2 TX white-green RX 1 3 RX white-orange TX 3 20 DTR white-brown POWER +V 7 4 RTS blue POWER +V 4 7 SIGNAL GND green GND 2 P/N C2002 is for use with Sun SPARCstation or SPARCserver serial ports A or B. The DTE end of this cable uses a DB-25M connector. P/N C2001 is for use with PC s that have a DB-25 connector. The DTE end of this cable uses a DB-25F connector. M indicates male/pin type connector. F indicates female/socket type connector. 8
9 Cable P/N C2012 DCE Serial Port to Sensorsoft Device DB-25M to RJ45 modular plug DCE Port Sensorsoft Device 3 TX white-green RX 1 2 RX white-orange TX 3 6 DSR white-brown POWER +V 7 5 CTS blue POWER +V 4 7 SIGNAL GND green GND 2 P/N C2012 is for use with some multiport cards and terminal servers that have a DCE pin-out. M indicates male/pin type connector. 9
10 Writing programs for the Sensorsoft Power Sensor The following describes how to write your own programs for the Sensorsoft Power Sensor. This Sensorsoft device uses a binary, packet-formatted, master-slave protocol. All data is represented in the little endian format - least significant byte is first and the most significant byte is last. Your host computer (master) must send commands to and receive responses back from the Sensorsoft device (slave). Use the following parameters when programming the serial port where the Sensorsoft device is connected: Bit rate: 1200 bps Bits: 8 Parity: none Stop bits: 1 Flow control: none Null discard: do not strip NULL bytes In order to make use of the port powered feature of the Sensorsoft device you must enable serial port lines DTR and RTS when the port is opened. A delay of 1-2 seconds is required after opening the serial port before any commands are sent to the Sensorsoft device. This delay allows the Sensorsoft device to power-up correctly before it receives any commands and prevents incorrect readings. You should also be aware that the Sensorsoft device has an inter-packet retry time-out delay. This delay is one (1) second and is encoded into the Sensorsoft device s firmware. If your program sends a command to the Sensorsoft device and it receives no response, your program must wait at least one (1) second before re-sending that command. Possible reasons that a Sensorsoft device may ignore your commands can be due to data transmission (CRC) errors or improper power-up delay during hot plugging. Sending commands to the Sensorsoft Power Sensor Each command packet your host sends to the Sensorsoft Power Sensor must be in the following format: <CMD-byte> <PACKETlength-bytes> <ADDRESS-bytes> <ARGUMENT-byte> <CRC-bytes> CMD-byte A single byte command indicating the desired action the Sensorsoft Power Sensor device should carry out. PACKETlength-bytes Two bytes indicating the total length of the packet from start to finish (includes CRC bytes). ADDRESS-bytes The six-byte (48-bit) address of the device you are sending the command to. For RS232 Sensorsoft Devices this is always decimal 1. 10
11 ARGUMENT-byte The number of the Sensorsoft Power Sensor's internal register you want to read or write. This byte must be 01h (register 1) to read the Boolean state of the sensor. This byte is not required for the status command. CRC-bytes A two byte (16 bit) Cyclic Redundancy Check that is calculated on the entire packet from the CMD byte to the last ARGUMENT byte or ADDRESS byte. Send the following bytes to request a status reading: Hex C1 0B Send the following bytes to request the Boolean state of the sensor: Hex C5 0C E 49 Note: In the above examples the last two bytes are CRC bytes that were pre-calculated. 11
12 Receiving responses from the Sensorsoft Power Sensor Each response packet the Sensorsoft Power Sensor returns is in the following format: <RESPONSE-byte> <PACKETlength-bytes> <DATA-byte(s)> <CRC-bytes> RESPONSE-byte A single byte response code indicating the type of response. Valid codes are 90 hex or 94 hex. PACKETlength-bytes Two bytes indicating the total length of the packet from start to finish (includes CRC bytes). DATA-byte(s) Most responses return additional data in the form of byte(s). In response to a command to read the sensor's Boolean state, one byte is returned for DATA-byte(s). Receiving a 00h byte in this placeholder indicates a POWER OK condition while a 01h indicates a POWER FAIL condition. In response to a status command, one byte is returned for DATA-byte(s). See SENSORSOFT DEVICE STATUS BYTE FORMAT chart. CRC-bytes A two byte (16 bit) Cyclic Redundancy Check. This placeholder is filled with CRC bytes calculated by the Sensorsoft device on the entire packet from the RESPONSE byte to the last DATA-byte. These bytes allow the host to verify the integrity of the response packet. You may choose to use or ignore these bytes depending on your programming skill or application. The Sensorsoft device returns a normal RESPONSE-byte (90 hex) in acknowledgement that the previous host command was received and executed without errors. The Sensorsoft device only acknowledges correctly received commands that have no CRC errors. If the Sensorsoft device detects a CRC error in a received command packet, it does not respond to the command. It is considered the job of the host to time-out and re-transmit that command packet. When an internal problem occurs inside the Sensorsoft device it sends out an abnormal response byte (94 hex) in response to any command from the host. If the host receives this response byte, it must immediately read and interpret the Sensorsoft device s status to determine the problem. See SENSORSOFT DEVICE STATUS BYTE FORMAT chart. The generator polynomial used for the CRC is hexadecimal The following references provide information for readers who wish to use the CRC capability; Calculating CRC s by Bits and Bytes, Greg Morse, Byte Magazine, September 1986, Pg Implementing CRC's, Jack Crenshaw, Embedded Systems Programming Magazine, January 1992, Pg Technical Aspects of Data Communication, John McNamara, Digital Equipment Press 1982, Pg Data and Computer Communications, 2nd edition, William Stallings, Macmillan Publishing, Pg The modem reference: the complete guide to selection, installation, and applications, 2nd edition, Michael A Banks, Brady Publishing 1991, Pg
13 SENSORSOFT DEVICE STATUS BYTE FORMAT BIT NAME DESCRIPTION 0 Low power supply Voltage is unacceptable for reliable operation 1 IRQ enable N/A 2 IRQ pending N/A 3 Power-up Sensor just powered-up 4 Tamper N/A 5 NV option N/A 6 EEPROM fail N/A 7 Future use N/A A logic one condition on any of these bits indicates the condition is set or active. Otherwise they are reset to logic zero. It is a good practice for the host to check the status of the Sensorsoft device on a regular basis in case a bit changes state. If bit 0 is set, this indicates that the Sensorsoft device power supply voltage is too low. When bit 3 is set, this indicates that the Sensorsoft device has just powered-up. This bit gets reset after the status is read. Bits 1,2,4,5,6 and 7 can be ignored; they are not used in the SP6400J. Reading the Sensorsoft ID Record Every Sensorsoft Device (SSD) accepts an identification (ID) command, whose response can be used to uniquely identify the type of SSD currently connected. Specifically, the model number and description can be extracted from the SSD s ID response, allowing application software to determine the specific model of the SSD connected and to configure itself appropriately. The format of the ID command is identical to the format of all other commands, described earlier. Send the following bytes to the SSD to request the ID: Hex <C3h> <0Bh> <00h> <01h> <00h> <00h> <00h> <00h> <00h> <20h> <5Eh> The ID response contains four variable-length null-terminated strings. The sequence of four strings begins at the 10 th byte in the response packet. To read the SSD s description, count to the 10 th byte in the ID response and extract the following ASCII null-terminated string. Following this is the manufacturer s name; also a null-terminated string. 13
14 The third null-terminated string is the SSD s model number. The model number can be used to uniquely identify the type of SSD, so that your software can configure itself appropriately for different models of SSDs. The fourth and final null-terminated string is the SSD s firmware version. Structure of the ID response packet Byte Description of field 1 Response byte 2-3 Packet length 4-9 Not used 10 Device name or description (null-terminated) ~ Manufacturer (null-terminated) ~ Model Number (null-terminated) ~ Firmware Version (null-terminated) ~ Record Terminator (FFh) ~ CRC bytes (2) Sample ID response packet from a SP6400J Sensorsoft Power Sensor Byte Contents 1 <90h> 2 <46h> 3 <00h> 4-9 <01h> <00h> <00h> <01h> <03h> <07h> 10 Sensorsoft (TM) Power Sensor <00h> ~ Sensorsoft Corp. <00h> ~ SP6400 <00h> ~ 1.02 <00h> ~ <FFh> ~ <09Dh> <017h> 14
15 Getting Help Limited Warranty Sensorsoft Corporation warranties Sensorsoft products to be free from manufacturing defects for a period of two years. This includes parts and labor. All shipping and brokerage fees are your responsibility when returning a Sensorsoft product for warranty claims. The following will void the warranty and 30 day money back guarantee: signs of water or chemical damage cracks to the housing signs of tampering or reverse engineering Technical Support If in the unlikely event you should have problems installing or using your Sensorsoft product and the previous sections of this manual have failed to provide a solution, we offer technical support to help you overcome your difficulties (see web site address below). No-charge installation and configuration support is provided for 90 days, after that there is a per-incident fee. Sensorsoft Corporation does not provide free support to those wishing to write their own software; this is available on a charge-per-incident basis only. Please contact us for current rates. World Wide Web: support@sensorsoft.com 30 Day Money Back Guarantee If for any reason you want to return a Sensorsoft product for a refund, you can do so within 30 days (calendar days) of your purchase. The refund does not include shipping or brokerage fees you may have incurred or paid. Returns If returning a product or item, please keep in mind the follow guidelines: Contact Sensorsoft for an RMA number (Return Material Authorization). Provide a detailed explanation or reason for returning the product. Return shipments that bear no RMA number (on the outside of the package) or are not prepaid for shipping/clearing charges, will be refused. 15
Sensorsoft. Sensorsoft Relay User Manual. Model SR6171J. Manual P/N Rev 2 March 27, 2003
Sensorsoft Sensorsoft Relay User Manual Model SR6171J Manual P/N 071-0058 Rev 2 March 27, 2003 Copyright 1999-2003 Sensorsoft Corporation, All rights reserved. Sensorsoft and Soft Relay are trademarks
More informationSensorsoft. Sensorsoft Humidity Meter User Manual. Models SM6204J and SM6204C. Manual P/N Rev 5 March 27, 2003
Sensorsoft Sensorsoft Humidity Meter User Manual Models SM6204J and SM6204C Manual P/N 071-0030 Rev 5 March 27, 2003 Copyright 1999-2003 Sensorsoft Corporation, All rights reserved. Sensorsoft and Soft
More informationSensorsoft Thermometer User Manual
Sensorsoft Thermometer User Manual Models ST6105J, ST6105C and ST6154J Manual P/N 071-0014 Rev 12 March 12, 2017 Copyright 1999-2017 Sensorsoft Corporation, All rights reserved. Sensorsoft and Soft Thermometer
More informationRemote Watchman Device Server User Manual
Remote Watchman Device Server User Manual Software Version 4.0 Manual P/N 071-0043 Rev 8 September 29, 2016 Copyright 2000-2016 Sensorsoft Corporation, All rights reserved. Sensorsoft, SCOM and Remote
More informationAB300-Series Automated Filter Wheels
AB300-Series Automated Filter Wheels User Manual 1049478 August 2006 1. Introduction 1.1 Mission Statement Our mission is to provide our customers with reliable products, on time, and at a fair price.
More informationUSER MANUAL MODEL 2017P MODEL 2017P60. RS-232 to 20mA and. RS-232 to 60mA Current Loop Converters
USER MANUAL MODEL 2017P RS-232 to 20mA and MODEL 2017P60 RS-232 to 60mA Current Loop Converters 07M2017P-E Doc# 073051UE Revised 5/7/96 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 1.0
More informationSC532A 9-PIN PERIPHERAL TO RS232 INTERFACE INSTRUCTION MANUAL
SC532A 9-PIN PERIPHERAL TO RS232 INTERFACE INSTRUCTION MANUAL REVISION: 7/02 COPYRIGHT (c) 1998-2002 CAMPBELL SCIENTIFIC, INC. This is a blank page. Warranty and Assistance The SC532A 9-PIN PERIPHERAL
More informationIC-485S /IC-485SI. If anything is damaged or missing, contact your dealer.
User Manual IC-485S /IC-485SI Read this guide thoroughly and follow the installation and operation procedures carefully in order to prevent any damage to the units and/or any devices that connect to them.
More informationFCC Information. RoHS This product is RoHS compliant. SJ/T The following contains information that relates to China.
FCC Information This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
More informationUSER S MANUAL. PH232Ex1. #1 RS-232 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH232Ex1-UM-001 IPEX. (IP Electronix)
USER S MANUAL PH232Ex1 Doc No: PH232Ex1-UM-001 #1 RS-232 Serial Port to Ethernet, Terminal Server/Client IPEX (IP Electronix) Contents 1. INTRODUCTION... 3 2. SPECIFICATIONS... 3 3. PACKAGE CHECKLIST...
More informationAn ISO-9001 Certified Company
USER MANUAL MODEL 1002 and 1002S Asynchronous 2-Wire / Coax Short Range Modem An ISO-9001 Certified Company Part #07M1002-C Doc. #050011UC Revised 4/28/98 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT
More informationThe Analyst. RS422/RS232 Tester. (Standard Model) User Manual
12843 Foothill Blvd., Suite D Sylmar, CA 91342 818 898 3380 voice 818 898 3360 fax www.dnfcontrolscom The Analyst RS422/RS232 Tester (Standard Model) User Manual Manual Revision 102506 Table of Contents
More informationFlex Series User Guide
User Programmable Current 4..20mA Digital RS485 Dual & Single Axis Up to 360º 2016 Flex Series User Guide Sensor Installation, Wiring, Flexware App Instructions Page 1 of 33 Page 2 of 33 Table of Contents
More informationUSER MANUAL. MODEL 1225 ParaLink TM Parallel Short Range Modem. SALES OFFICE (301) TECHNICAL SUPPORT (301)
USER MANUAL MODEL 1225 ParaLink TM Parallel Short Range Modem C E R T I F I E D An ISO-9001 Certified Company Part #07M1225-B Doc. #104011UB Revised 9/12/97 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT
More informationICP PANEL-TEC PEX3000 II
ICP PANEL-TEC PEX3000 II MODBUS PORT EXPANDER INSTALLATION AND OPERATION GUIDE REVISION HISTORY Revision Date Author Comments 000 29 Aug 2008 Keira Majors Initial release. 001 16 Sep 2008 David Walker
More informationDual-Link DVI over 2CAT6 Extender
Dual-Link DVI over 2CAT6 Extender EXT-DVI-2CAT6DL User Manual Technical Support: Telephone (818) 772-9100 (800) 545-6900 Fax (818) 772-9120 Technical Support Hours: 8:00 AM to 5:00 PM (PST) Monday thru
More informationTABLE OF CONTENTS. Communication Functions
TABLE OF CONTENTS Chapter 1: Chapter 2: Chapter 3: Chapter 4: General Features....................................................... 1-1 Functions......................................................
More informationKramer Electronics, Ltd. USER MANUAL. Model: TP Channel UXGA/Audio/RS-232 to CAT 5 Transmitter
Kramer Electronics, Ltd. USER MANUAL Model: TP-185 8 Channel UXGA/Audio/RS-232 to CAT 5 Transmitter Contents Contents 1 Introduction 1 2 Getting Started 1 2.1 Quick Start 2 3 Overview 3 3.1 Shielded Twisted
More informationVADDIO /CANON BU-SERIES PTZ CAMERAS
Camera and Electronic Products for Integrators Installation and User Guide VADDIO /CANON BU-SERIES PTZ CAMERAS Canon BU-45H Outdoor & BU-50H Indoor PTZ Cameras including Vaddio accessories for easy integration
More informationWiFi to RS-232 adapter user manual
WiFi to RS-232 adapter user manual WiFi to RS-232 adapter Package Contents: WiFi RS-232 adapter x 1 A4 User manual x 1 Mini USB Cable x 1 White Box Dimension: 11 x 6 x 5 (cm) Total Package Weight: 126
More informationQuick Start Installation Guide
apc/l Quick Start Installation Guide Version A2 Document Part Number UM-201 May 2010 OVERVIEW The apc/l is an intelligent access control and alarm monitoring control panel which serves as a basic building
More informationUSER MANUAL MODEL Bidirectional (IEEE-1284) Line Driver/Converter
USER MANUAL MODEL 2030 Bidirectional (IEEE-1284) Line Driver/Converter An ISO-9001 Certified Company Part # 07M2030-B Doc. #102121U, Rev. C Revised 1/22/08 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT
More informationThe Analyst RS422/RS232 Tester. With. VTR, Monitor, and Data Logging Option (LOG2) User Manual
12843 Foothill Blvd. Suite C Sylmar, California 91342 V: 818.898.3380 F: 818.898.3360 sales@dnfcontrols.com The Analyst RS422/RS232 Tester With VTR, Monitor, and Data Logging Option (LOG2) User Manual
More informationHDMI (HDBaseT) Matrix Switcher Series Ed.B July 2013 Elpro Video Labs
HDMI (HDBaseT) Matrix Switcher Series Ed.B July 2013 Elpro Video Labs ITEM NO.: 4 x 4 HDMI + HDBaseT Matrix Switcher With the latest and more affordable HDBaseT technology extend HDMI sources up to 100M
More informationI/O Interface DNA300
DNA300 OPERATIONS MANUAL 1 Ring Communications, Inc. Crisis Alert System I/O Interface DNA300 2 DNA300 OPERATIONS MANUAL 2006/06/13 DNA300 OPERATIONS MANUAL 3 Contents INTRODUCTION... 5 INSTALLATION...
More informationSerial to Ethernet Converter HL-SE02P-V1. User s Manual V3.606
Serial to Ethernet Converter HL-SE02P-V1 User s Manual V3.606 UContents Table Welcome... 2 Package Contents. 2 Feature. 2 Application 3 Specification. 4 Hardware Guide 5 Ping Assignments. 6 Factory Default
More informationRS232/RS485/RS422 to TCP/IP Converter ITEM NO.: RS007
RS232/RS485/RS422 to TCP/IP Converter ITEM NO.: RS007 RS007 is a universal data converter which support serial RS232, RS422 and RS485 to the TCP / IP intelligent communication converter, it offers RS485/RS422
More informationSP x4 DVI over Single CAT5 Distribution Amplifier. User Manual. Made in Taiwan
SP-1014 1x4 DVI over Single CAT5 Distribution Amplifier User Manual Made in Taiwan Safety and Notice The SP-1014 1x4 DVI over Single CAT5 Distribution Amplifier has been tested for conformance to safety
More informationConnector and Cable Specifications
APPENDIX B This appendix describes the pinouts and cabling requirements for the interfaces and cables used on the Cisco ubr925 cable access router. All connectors for these interfaces are on the rear-panel,
More informationTM600 Real time flow totalizer and transmitter
TM600 Real time flow totalizer and transmitter Installation and user guide Rev 1 Auper Electronic Controls Inc All rights reserved 2013 GENERAL INFORMATION FCC INFORMATION This device complies with Part
More informationUC-2000 Installation Manual Unicorn Computers Technology Limited
UC2000 Installation Manual Copyright 2003. All rights reserved. Table of Contents Specifications 2 Enclosure for the UC2000 Controller 3 Unicorn Access Control System Configuration 4 UC2000 Controller
More informationSecured Series: Hub Plus Kit Single Door Controller Package Installation Manual
Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual This package is designed to simplify the connections to our Secured Series Hub Plus Controller. This will translate into
More informationConettix ITS-D6686-INTL
Conettix ITS-D6686-INTL EN Installation Guide Ethernet Network Adapter Conettix ITS-D6686-INTL Installation Guide Contents Contents 1.0 Introduction... 3 1.1 Network Interface... 3 1.2 Serial Interface...
More informationINTELLIS. Modbus Direct Network Monitor
INTELLIS Modbus Direct Network Monitor System Installation and Operation Manual Phone: (201) 794-7650 Fax: (201)794-0913 Chapter 1 Modbus Protocol Revision History Revision 1.0 30 April, 2002 Initial Version
More informationDual Serial Shield User Manual
Dual Serial Shield User Manual PN: 2050 Berkshire Products, Inc. Phone: 770-271-0088 http://www.bkp-store.com/ Rev: 1.00 Copyright 2013 Table of Contents 1 Introduction... 2 1.1 XB compatibility... 2 2
More informationBluetooth TO Serial CONVERTER E-P132-B
Bluetooth TO Serial CONVERTER E-P132-B 1 Table of Contents Introduction..3 Package checklist...4 Product Specification...5 Product Panel Views Description...6 Product Views. 6 DC-In Power Outlet 6 Antenna
More informationAppendix A Cable Pinouts
Appendix A Cable Pinouts This appendix lists the cables and connector pinout assignments for the cables used with the ERX-7xx models and ERX-14xx models. Topic Page SRP I/O Module 163 CT1 and CE1 I/O Modules
More informationUSER MANUAL. S3MBW HDMI Multi-format Extender Over CAT5e/CAT6. Back View. Front View. Covid Part Numbers
Front View Back View Covid Part Numbers Black Anodized: S3MBW-200-BA Clear Anodized: S3MBW-200-CA Antique White: S3MBW-200-AW Black PC: S3MBW-200-BL White PC: S3MBW-200-WH Table of Contents Introduction...2
More information2001 by NEC America. All Rights Reserved. Printed in U.S.A.
These instructions are customized for the CNet Modem V.90 k bps modem (P/N D) contained in the i Modem Kit P/N 9, i Modem Kit P/N 90B, and the i and 0i Modem Kit P/N 9. The modem connected to the system
More informationBluetooth to RS-232 Converter. RT-132B Bluetooth Adaptor Operation Manual
Bluetooth to RS-232 Converter RT-132B Bluetooth Adaptor Operation Manual First Edition, Nov 2007 Table of Contents 1. Introduction.. 2 2. Package checklist.. 3 3. Product Specification... 4 4. Product
More informationLantech LSC-1102B SERIAL TO TCPIP CONVERTER. User Manual
Lantech LSC-1102B SERIAL TO TCPIP CONVERTER User Manual V1.0 Sep 2016 Table of Contents 1. Introduction 3 Overview 4 Product Specifications 8 2. Description & Installation 10 Product Panel Views 10 LED
More informationC-Bus Pascal Automation Controller
C-Bus Pascal Automation Controller Installation Instructions 5500PACA Copyright Clipsal Integrated Systems Pty Ltd 2005. All rights reserved. This material is copyright under Australian and international
More informationCable Pinouts. SRP I/O Module
Cable Pinouts A This appendix lists the cables and connector pinout assignments for the cables used with the ERX-7xx models and ERX-14xx models. Topic Page SRP I/O Module A-1 CT1 and CE1 I/O Modules A-4
More informationActive RFID Reader User Manual
1. Package Contents: Active RFID Reader x 1 Battery power line with connector x 1 User manual x 1 USB Cable x 1 0dBi Dipole Antenna x 1 Active RFID Reader User Manual IP Address White box: Dimension: 10
More informationEtherSeries. EtherSeries CR-2. CR-2-Opto. User s Guide. Revised October 7, 2013 Firmware Version 1.X
EtherSeries EtherSeries CR-2 & CR-2-Opto User s Guide Revised October 7, 2013 Firmware Version 1.X TABLE OF CONTENTS SECTION 1 - DESCRIPTION... 2 SECTION 2 - SPECIFICATIONS... 4 SECTION 3 - INSTALLATION...
More informationTRAINING GUIDE LEVEL 3 MODBUS WRITE IMPORT COMMAND
OleumTechTM TRAINING GUIDE LEVEL 3 MODBUS WRITE IMPORT COMMAND MUST BE FAMILIAR WITH LEVEL 1 TRAINING MATERIALS BEFORE MOVING FORWARD Doc ID# 80-6010-001b TABLE OF CONTENTS 1. WHAT IS NEW WRITE IMPORT
More informationMulti-Port Controller
Multi-Port Controller TABLE OF CONTENTS SECTION 1 DESCRIPTION... SECTION - SPECIFICATIONS... SECTION - INSTALLATION... SECTION - FRONT PANEL CONTROLS AND INDICATORS...9 SECTION - NETWORK MANAGEMENT PORT...10
More informationQuick Start Installation Guide
istar Pro Quick Start Installation Guide Version B0 Part Number UM-069 January 2005 OVERVIEW This guide defines all of the commonly used connection methods to the istar Pro. It outlines how to wire readers
More informationVP Process Inc. Model: VP-EC-RDU Modbus RTU LCD Display
VP Process Inc. Model: Modbus RTU LCD Display User Manual Ver: 2.0 Aug. 2017 P a g e 1 Standard Features Low Power (12-24 VDC) 2.1 x 5mm Barrel Plug, RJ45 and Terminal Block Input On-Board Local Temperature
More informationConettix ITS-D6686-UL PRELIMINARY. Installation Guide. Ethernet Network Adapter
Conettix ITS-D6686-UL EN Installation Guide Ethernet Network Adapter Conettix ITS-D6686-UL Installation Guide Contents Contents 1.0 Introduction... 3 1.1 Network Interface... 3 1.2 Serial Interface...
More informationConettix ITS-D6686-UL
Conettix ITS-D6686-UL EN Installation Guide Ethernet Network Adapter Conettix ITS-D6686-UL Installation Guide Contents Contents 1.0 Introduction... 3 1.1 Network Interface... 3 1.2 Serial Interface...
More informationUSER MANUAL. MODEL 1003 and 1003S Asynchronous, 2-Wire, Carrier Sense Short Range Modem
USER MANUAL MODEL 1003 and 1003S Asynchronous, 2-Wire, Carrier Sense Short Range Modem An ISO-9001 Certified Company Part #07M1003-B Doc. #050021UB Revised 4/28/98 SALES OFFICE (301) 975-1000 TECHNICAL
More informationZM24x Quick-Connect Industrial Modem. User s Manual
ZM24x Quick-Connect Industrial Modem User s Manual Version 1.1 2004 ZYPEX, Inc. All Rights Reserved 1 ZM24x Quick-Connect Industrial Modem Since the equipment explained in this manual has a variety of
More informationUser Manual rev: Made in Taiwan
SP-1014 1x4 DVI Splitter over Single Cat.X with HDCP Support User Manual rev: 111209 Made in Taiwan The SP-1014 1x4 DVI Splitter over Single Cat.X with HDCP Support has been tested for conformance to safety
More informationIndustrial Serial Device Server
1. Quick Start Guide This quick start guide describes how to install and use the Industrial Serial Device Server. Capable of operating at temperature extremes of -10 C to +60 C, this is the Serial Device
More information45SD Series Bus Expansion Cards For use with Q45X Series Photoelectric Sensors on SDS Bus Networks
45SD Series Bus Expansion Cards For use with Series Photoelectric Sensors on SDS Bus Networks Banner model 45SD plug-in bus cards enable a Banner Series sensor to establish a logical relationship between
More informationUSER MANUAL. DV-HXT-1 HDMI to CAT5e /6 EXTENDERS LIT1375A
USER MANUAL DV-HXT-1 HDMI to CAT5e /6 EXTENDERS 244 Bergen Boulevard, Woodland Park, NJ 07424 Tel 973-785-4347 FAX 973-785-3318 Web: www.fsrinc.com LIT1375A 2 Proprietary Information All information in
More informationHDMI (HDBaseT) Matrix Switcher Series
HDMI (HDBaseT) Matrix Switcher Series ITEM NO.: HE04M 4 x 4 HDMI + HDBaseT Matrix Switcher With the latest and more affordable HDBaseT technology extend HDMI sources up to 100M at 1080p or 1920x1200. HE04M
More informationIntegrity Instruments
Integrity Instruments P.O. Box 451 Order Phone 800-450-2001 Pine River Minnesota Fax Phone 218-587-3414 56474 USA Tech Phone 218-587-3120 http://www.integrityusa.com 485-25A High Speed RTS Enabled RS-232
More informationDraper Low Voltage, Remote Control, Serial and Network Wiring Guide
Draper Low Voltage, Remote Control, Serial and Network Wiring Guide Copyright 2007 Draper Inc. Form LV-RC-Serial-Network_Wiring07 Print ed in U.S.A. Draper Low Voltage, Remote Control, Serial and Network
More informationMX200 SERIES Modbus Card 50P GE Zenith Controls. Operation and Maintenance Manual 50R-2200B 12/00
g MX200 SERIES Modbus Card 50P-1105 GE Zenith Controls 50R-2200B 12/00 Operation and Maintenance Manual Table of Contents Overview...01 Page LED Indicator...02 Installation...03 Installing the Network
More informationUSER MANUAL. MODEL 2011 High Speed Asynchronous to Synchronous Converter
USER MANUAL MODEL 011 High Speed Asynchronous to Synchronous Converter Part# 07M011-A Doc# 0601UA Revised 03/16/94 SALES ICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 http://www.patton.com 1.0 WARRANTY
More information-C5RS-LC RS232 EXTENDER
XTENDEX Series ST-C5RS-LC RS232 EXTENDER Installation and Operation Manual ST-C5RS-LC RS232 Extender Man249 Rev. 10/30/17 TRADEMARK XTENDEX is a registered trademark of Network Technologies Inc in the
More informationI/O SIGNAL CONDITIONER
Technical Data Sheet No. TD9809M Rev. F Date of Issue: December 9, 2009 OPERATING MANUAL I/O SIGNAL CONDITIONER CAUTION: THIS PRODUCT DOES NOT PROVIDE GALVANIC ISOLATION. DO NOT ATTEMPT USE OF THIS PRODUCT
More information+ (5~27 VDC) GND. Bluetooth V4.1 BLE RS-232 Serial Adapter. Model: BLE-232B. 1. Package content: BLE RS-232 adapter
Bluetooth V4.1 BLE RS-232 Serial Adapter 1. Package content: BLE RS-232 adapter Model: BLE-232B Package Contents: BLE RS-232 adapter x 1 Screw x2, Screw nut x 2 A4 User manual x 1 Mini USB Cable x 1 White
More informationUSB 2.0 LR Extender. EXT-USB2.0-LR User Manual.
USB 2.0 LR Extender EXT-USB2.0-LR User Manual www.gefen.com ASKING FOR ASSISTANCE Technical Support: Telephone (818) 772-9100 (800) 545-6900 Fax (818) 772-9120 Technical Support Hours: 8:00 AM to 5:00
More informationIntelligent Devices IDI 1100 Series Technical Manual
Intelligent Devices IDI 1100 Series 4411 Suwanee Dam Road, Suite 510 Suwanee, GA 30024 T: (770) 831-3370 support@intelligentdevicesinc.com Copyright 2011, Intelligent Devices, Inc. All Rights Reserved
More informationUser Manual. VGA I DVI-D / HDMI to Single Cat Transmitter Universal Wall Interface. Model Name: UWITX. Total Digital Connectivity Solutions
User Manual Total Digital Connectivity Solutions VGA I DVI-D / HDMI to Single Cat Transmitter Universal Wall Interface Model Name: UWITX Cautions: 1. Digital Extender logo is our own trademark of RTcom
More informationPS232. RS-232 to PS/2 Keyboard Port Adapter Part # SA0009 (Version 4.0) Copyright 2003 L3 Systems, Inc. Redmond
PS232 RS-232 to PS/2 Keyboard Port Adapter Part # SA0009 (Version 4.0) Copyright 2003 L3 Systems, Inc. Redmond Quick Reference Command Description Pg ~H Help Screen Displays short command reference 4 ~V
More informationBluetooth to RS-232&RS422/485. EX-9132B/BI Bluetooth Adapter Operation Manual
Bluetooth to RS-232&RS422/485 EX-9132B/BI Bluetooth Adapter Operation Manual First Edition, Jun 2008 Table of Contents 1. Introduction 2 2. Package checklist 3 3. Product Specification 4 4. Product Panel
More informationCR3000 Copy Reader. Installation Guide
CR3000 Copy Reader Installation Guide CONTENTS CONTENTS 1 CR3000 Installation Guide 1 What you get: 2 Installation Overview 3 Install the Reader 4 Mount the Reader 4 Connect the Reader Cables 5 Connect
More informationEnhanced Mini-Chansim Model VCS-232
Enhanced Mini-Chansim Model VCS-232 Operations Manual ViaSat Inc. 6155 El Camino Real Carlsbad, CA 92009 http://www.viasat.com SAFETY WARNING Always observe standard safety precautions during installation,
More informationUSER MANUAL. VA-1USB-T USB Transmitter. VA-1USB-R USB Receiver MODELS: P/N: Rev 3
KRAMER ELECTRONICS LTD. USER MANUAL MODELS: VA-1USB-T USB Transmitter VA-1USB-R USB Receiver P/N: 2900-300209 Rev 3 Contents 1 Introduction 1 2 Getting Started 2 2.1 Achieving the Best Performance 2 2.2
More informationMS Protocol Converter. User Manual. Firmware version 2.0 ISI. Instrumental Solutions, Inc.
MS1-2150 Protocol Converter User Manual Firmware version 2.0 ISI Instrumental Solutions, Inc. WWW.ISIDEV.NET Introduction The MS1-2150 protocol converter can take readings from 1 or more ModBus registers
More informationEA500. Installation Instructions Transponder
EA500 EN Installation Instructions Transponder EA500 Installation Instructions 1.0 Overview EN 2 1.0 Overview The EA500 Transponder is the Security Escort module that provides communications between the
More informationConettix ITS-D6682-INTL
Conettix ITS-D6682-INTL EN Installation Guide Ethernet Network Adapter Conettix ITS-D6682-INTL Installation Guide Contents Contents 1.0 Introduction... 3 1.1 Network Interface... 3 1.2 Serial Interface...
More informationPACSystems* RX3i IC695CMM002-EG and IC695CMM002CA-EG IC695CMM004-EG, IC695CMM004CA-EG, and IC695CMM004LT-EG
September 2017 PACSystems* RX3i IC695CMM002-EG and IC695CMM002CA-EG IC695CMM004-EG, IC695CMM004CA-EG, and IC695CMM004LT-EG Serial Communications Modules PACSystems* RX3i Serial Communications modules expand
More informationSC32A OPTICALLY ISOLATED RS232 INTERFACE INSTRUCTION MANUAL
SC32A OPTICALLY ISOLATED RS232 INTERFACE INSTRUCTION MANUAL REVISION: 1/93 COPYRIGHT (c) 1987, 1993 CAMPBELL SCIENTIFIC, INC. WARRANTY AND ASSISTANCE The SC32A OPTICALLY ISOLATED RS232 INTERFACE is warranted
More informationData Broadcast Switch
Data Broadcast TABLE OF CONTENTS SECTION 1 - DESCRIPTION... SECTION - SPECIFICATIONS... SECTION - INSTALLATION... SECTION - FRONT PANEL CONTROLS AND INDICATORS... SECTION - INTERFACE SIGNALS AND CABLING...
More informationRS-232 Connector Pin Assignments
APPENDIXB This appendix lists the connector pin assignments for the CDEs, and includes the following sections: Serial Console-Interface, page B- Ethernet, page B- Cable Pin Assignments, page B- Serial
More informationMODEL : RS2000 TECHNICAL MANUAL
MODEL : RS2000 PORT POWERED RS232 SWIPE READER TECHNICAL MANUAL May, 2000 I FCC This Equipment, RS2000, had been tested and found to comply with the limits for a Class A digital device, pursuant to part
More information+ (5~27 VDC) GND. Bluetooth V4.2 BLE RS-232 Serial Adapter. Model: BLE-232D-E. 1. Package content: BLE RS-232 adapter
1. Package content: BLE RS-232 adapter Bluetooth V4.2 BLE RS-232 Serial Adapter Model: BLE-232D-E Package Contents: BLE RS-232 adapter x 1 A4 User manual x 1 Mini USB Cable x 1 White Box: 11 x 6 x 5 (cm)
More informationHA7E-User Manual ASCII RS232 to 1-Wire Host Adapter
HA7E-User Manual ASCII RS232 to 1-Wire Host Adapter http://www.embeddeddatasystems.com FEATURES ASCII command support for all 1-Wire devices. Powered by RS232 handshake lines. Automatic power up and power
More informationWIE485 and WIE232. Wiegand to RS485 or RS232 bidirectional interface converters for systems with contactless readers
Wiegand to RS485 or RS232 bidirectional interface converters for systems with contactless readers 24. srpna 2016 w w w. p a p o u c h. c o m WIE485 and WIE232 Product Data Sheet Created: 5.10.2010 Last
More informationProliphix EPA-60 Installation Guide
Proliphix EPA-60 Installation Guide Rev 1.2 Page 2 of 5 Installation CAUTION THE EPA-60 SHOULD ONLY BE POWERED WITH THE PROLIPHIX POWER SUPPLY INCLUDED WITH THE EPA-60. DO NOT POWER THE EPA-60 WITH ANY
More informationST-C5VRS-600 VIDEO AND RS232 EXTENDER Installation and Operation Manual
NTI R NETWORK TECHNOLOGIES INCORPORATED XTENDEX TM Series ST-C5VRS-600 VIDEO AND RS232 EXTENDER Installation and Operation Manual Manual 039 Rev. 3/13/03 WARRANTY INFORMATION The warranty period on this
More informationMD9 MULTIDROP INTERFACE INSTRUCTION MANUAL
MD9 MULTIDROP INTERFACE INSTRUCTION MANUAL REVISION: 01/05/03 COPYRIGHT (c) 1987-2003 CAMPBELL SCIENTIFIC, INC. This is a blank page. WARRANTY AND ASSISTANCE The MD9 MULTIDROP INTERFACE is warranted by
More informationCable Specifications. Interface Specifications. Fiber-Optic Specifications APPENDIXB
APPENDIXB This appendix lists the cable specifications for supported modules on the Cisco 7600 series router. The following signal summaries are contained in this appendix: Interface Specifications, page
More informationPIM Presco Interface Module
INTRODUCTION The Interface Module (PIM) can be used to convert commonly used data formats to Nidac, or format data. PIM Interface Module Series 2 Revision B FEATURES Converts from,, Nidac, Clock & Data
More informationACE PLUS CORP. APCON100 series Operation Manual RS-232 to Ethernet Converter
APCON100 series Operation Manual RS-232 to Ethernet Converter Page 1 of 24 APCON100 series Operation Manual Index Chapter 1 Specifications 2 Chapter 2 Introduction 3 Chapter 3 Easy Installation 4 Chapter
More informationNetBiter Serial Server User Manual
User Manual IntelliCom Innovation AB Linjegatan 3D SE-302 50 Halmstad SWEDEN Phone +46 35 18 21 70 Fax +46 35 17 29 09 email info@intellicom.se web www.intellicom.se Revision List Revision Date Author
More informationDGH A3000 Configuration Guide For use with DGH Modules
DGH A3000 Configuration Guide For use with DGH Modules Revision Date: 12/07/05 Version: 1.00 Contact Information: http://www.dghcorp.com Ph: (603) 622-0452 Fax: (603) 622-0487 Mailing Address: DGH Corporation
More informationLGate 120 Installation Guide - Appendix
LGate 120 Installation Guide - Appendix This guide contains information on RS485 and Ethernet connections to the LGate 120 3GY Version 1.1 Table of Contents Important Product Information 3 The LGate 120
More informationWiFi to RS-232 adapter user manual
User Manual V1.2 Date: 2015.01.28 WiFi to RS-232 adapter user manual Package Contents: WiFi RS-232 adapter x 1 WiFi to RS-232 adapter 2 dbi dipole antenna x 1 A4 User manual x 1 USB Cable x 1 Power cable
More informationControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet
General Information ControlKeeper 4 Installation Sheet Model# CK4-120NO- Model# CK4-277NO The ControlKeeper-4 model is shipped in one package and is configured with either a 120V or a 277V transformer.
More informationDocument Name : User Manual for SC10B : RS232 to Bluetooth Converter.
Document Name : User Manual for SC10B : RS232 to Bluetooth Converter. SC10B is Bluetooth V.2.0-certified and is backward compatible with v1.1/1.2 devices. You can connect between your computers (Master)
More informationUSB 2.0 LR 4-Port Extender
USB 2.0 LR 4-Port Extender GTB-USB2.0-4LR User Manual www.gefentoolbox.com ASKING FOR ASSISTANCE Technical Support: Telephone (818) 772-9100 (800) 545-6900 Fax (818) 772-9120 Technical Support Hours:
More informationDATA CONNECT ENTERPRISE
DATA CONNECT ENTERPRISE User s Manual IG202T and IGV23 Modem Document Number 520-01005-001 Rev. A DATA CONNECT Contents Contents... iii Figures... iv Chapter 1 Introduction... 5 Features...6 Applications...7
More informationKramer Electronics, Ltd.
Kramer Electronics, Ltd. Preliminary USER MANUAL Model: FC-50 RS-232 Range Extender Contents Contents 1 Introduction 1 2 Getting Started 1 2.1 Quick Start 2 3 Overview 3 3.1 About the Power Connect Feature
More informationMiniature Asynchronous 4-Wire High Speed Modems
ME1862A-F ME1863A-F JULY 2003 ME1862A-M ME1863A-M Miniature Asynchronous 4-Wire High Speed Modems CUSTOMER SUPPORT INFORMATION Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500)
More information