5/2 Product overview. 5/3 Distribution board components. 5/9 Built-in components. 5/17 Mounting components 5. Siemens ET B1 10/2009
|
|
- Jodie Preston
- 5 years ago
- Views:
Transcription
1 Siemens AG 9 BETA Protecting SR Busbar Systems /2 Product overview /3 Distribution board components /9 Built-in components /17 Mounting components Siemens ET B1 10/9
2 BETA Protecting SR Busbar Systems Siemens AG 9 Product overview Overview Devices Page Field of application Standards Used in Distribution board components /3 Busbars, busbar supports and covers for touch protection. Non-residential buildings Residential buildings Industry -- Built-in components /9 3-pole NEOZED bus-mounting bases or DIAZED bus-mounting bases, NEOZED bus-mounting switch disconnectors, LV HRC fuse switch disconnectors and device adapters. -- Mounting components /17 Bases, blanking covers, cover profiles for busbars, edges, slotted partitions, end covers for busbar supports, supports for blanking covers /2 Siemens ET B1 10/9
3 Siemens AG 9 BETA Protecting SR Busbar Systems Distribution board components Overview The use of busbar systems with their versatile rail-adaptable connection, switching and installation devices is an ideal and cost-effective electrotechnical enhancement of modern distribution boards due to their small footprint, compact design and quick assembly contacts. Mounting is implemented on longitudinal stays. The busbar spacing is mm I201_ $ Longitudinal stays % Busbar supports, three-phase & Cu busbars ( Terminals ) Support for blanking covers * Blanking cover + Supports, Touch protection cover - Busbar supports, single-phase Benefits Only a few distribution board components are required to ensure the integration of busbars in the distribution board. This saves time and space. The touch protection cover is sealable as standard and is quick and easy to attach to the supports thanks to the use of quick-release locking technology. Technical specifications Infeed, connection modules, three-phase SH3 38 SH3 3 8US BA00 8US AA00 Busbar center-to-center clearance mm Current carrying capacity of the terminal points A The specified current carrying capacities reflect the thermal load capability of the terminal points under favorable conditions (with the largest conductors it is possible to connect). This does not invalidate the assignment of conductor cross-sections and current carrying capacities as defined in national and international specifications. Tightening torques Nm Clamping space W H: mm Conductors that can be used mm Cu, re, rm, f, f+ae (reduction of the maximum conductor crosssections may be required) Cu, Al (connections with aluminum conductors are not maintenance free), rm, sm, f (70) Cu, rm, f, f+ae (reduction of the maximum conductor cross-sections may be required), la. Cu Cu, rm, f, f+ae (reduction of the maximum conductor cross-sections may be required), la. Cu 6/ Siemens ET B1 10/9 /3
4 BETA Protecting SR Busbar Systems Siemens AG 9 Distribution board components Selection and ordering data Dimensions DT Order No. Price PU PS*/ P. unit PG Weight approx. mm Unit(s) Unit(s) kg Longitudinal stays For mounting the assembly kits in unequipped distribution boards, two longitudinal stays are required for each assembly kit width 1 set = 2 stays Height 0 A 8GK4 81-4KK00 1 set 1 set A 8GK4 81-KK00 1 set 1 set A 8GK4 81-6KK00 1 set 1 set A 8GK4 81-7KK00 1 set 1 set A 8GK4 81-8KK00 1 set 1 set A 8GK4 82-8KK00 1 set 1 set Busbar supports For busbars with Busbar thickness of or 10 mm and busbar heights of 12, 1, 20, 2 or 30 mm, For mounting on longitudinal stays, with fixing screws Three-phase A 8GK KK N/PE busbar supports For flat copper profiles For /10 mm busbars A SH Cu busbars Cu cross-section 12 mm, current intensity 20 A 20 mm, current intensity 320 A 30 mm, current intensity 40 A mm, current intensity 630 A Length 20 A 8GK KK A 8GK KK A 8GK KK A 8GK KK A 8GK KK A 8GK KK A 8GK KK A 8GK KK A 8GK KK A 8GK KK A 8GK9 73-0KK A 8GK9 73-0KK A 8GK9 73-0KK A 8GK9 73-0KK A 8GK9 73-0KK A 8GK KK A 8GK KK A 8GK KK A 8GK KK A 8GK KK Cover profiles for busbars Busbar thickness mm Width 12 mm 1000 A 8US CA Width 1, 20, 2, 30 mm 1000 A 8US AA Busbar thickness 10 mm Width 12, 1, 20, 2, 30 mm 1000 A 8US BA /4 Siemens ET B1 10/9 * You can order this quantity or a multiple thereof.
5 Siemens AG 9 BETA Protecting SR Busbar Systems Distribution board components Infeeds, connection modules, three-phase For /10 mm busbars with cover With screwless terminals, mm long, 20 mm wide Conductor crosssection DT Order No. Price PU PS*/ P. unit PG Weight approx. mm 2 Unit(s) Unit(s) kg A SH With screw terminals mm long, 4 mm wide A 8US BA mm long, 81 mm wide A 8US AA (Shown without cover in the illustration, but cover included in delivery) C SH US AA00 Dimensions Conductor cross-section Tightening torques DT Order No. Price PU PS*/ P. unit PG Weight approx. mm 2 Nm Unit(s) Unit(s) kg Terminals for circular conductors Busbar thickness mm } 8US AA } 8US AB } 8US AD } 8US AC Busbar thickness 10 mm } 8US BA } 8US BB } 8US BD } 8US BC Terminals for one busbar Busbar thickness mm Width 12 mm A 8JH A 8JH A 8JH A 8JH A 8JK * You can order this quantity or a multiple thereof. Siemens ET B1 10/9 /
6 BETA Protecting SR Busbar Systems Siemens AG 9 Distribution board components Dimensions Conductor cross-section Tightening torques DT Order No. Price PU PS*/ P. unit PG Weight approx. mm 2 Nm Unit(s) Unit(s) kg Extension terminals For 12 x mm busbars (Busbar not included in the scope of delivery) (1 set = 2 units) 6.0 A 8JK set 10 sets Terminals for circular conductors 20 mm mm to 30 mm 10 mm A 8US BB Connection modules For 32-mm cover level with A 3NP BC box terminal mm 2 Dimensions (H x W) DT Order No. Price PU PS*/ P. unit PG Weight approx. mm mm Unit(s) Unit(s) kg Assembly kits Comprising touch protection cover and 4 supports Cutout width For three-phase busbar systems 216 mm A 8GK KK mm A 8GK KK mm A 8GK KK mm A 8GK KK mm A 8GK KK mm A 8GK KK Supports for blanking covers For blanking cover, for busbar mounting B SH / (2 units required for each section of blanking cover) Blanking covers Mounting on SH3 36 support for blanking covers Length Height 1000 mm 202 mm A SH /6 Siemens ET B1 10/9 * You can order this quantity or a multiple thereof.
7 Siemens AG 9 BETA Protecting SR Busbar Systems Dimensional drawings 8GK9 busbar support N/PE busbar support Connection module Distribution board components A , SECTION: A-A 20 4 Nm 1 6, 49, 36, A 20 NSE0_0168a 49, 8GK KK03 SH3 40 SH 38 I2_14000a I2_13999a Connection module Connection module Connection module I2_0710a US AA00 shown closed 8US AA00 shown open 8US BA00 I2_06439b 32 NSE0_0198 More information Material properties Busbar supports and busbar-mounting fuse bases (see "Built-in components" from page /9) are manufactured from glass-fiber reinforced, thermoplastic polyester (RAL 703, light gray). The material ensures excellent mechanical, chemical and electrical properties. Furthermore, the material has an extremely low flammability and meets the requirements of UL 94 V0. This satisfies the load requirements of the busbar supports at rated operational voltage 00 V and rated currents at A to 630 A, as well as the rated short-circuit strength 0 ka. Ambient temperatures When dimensioning the busbars based on rated currents, the ambient temperature and the Cu busbar temperature must also be taken into account. The location of the busbar system and its ability to dissipate heat through convection also play a key role in this calculation. Because conditions can vary for each distribution board, the values in the following table serve as a guideline only. However, they must be applied to the entire busbar length. Continuous currents depending on the Cu power rail dimensions and Cu busbar temperatures at 3 C ambient temperature Cu busbar dimensions H D Continuous current for open busbar run Ambient temperature 3 C Continuous current of fuse link Operational class gl/gg mm mm A A As far as other types of upstream protective devices are concerned, please observe the permissible continuous current of the busbar. Siemens ET B1 10/9 /7
8 BETA Protecting SR Busbar Systems Siemens AG 9 Distribution board components Dynamic rated short-circuit strength The electrodynamic load of the busbars depends on the level of short-circuit current, the length of the busbar section through which the current flows, the support spacing of the busbar supports and, of course, on the distance between the busbars themselves. This is because, for example, if an NH fuse system is connected upstream to the busbars in the protective device, the let-through current i D is the maximum current to flow through this protective device. The value i D depends on the maximum system short-circuit current and the current-limiting action of the protective device used. The permissible let-through values of the protective equipment are specified by the manufacturers in the form of a current limitation diagram as a function of the socalled prospective short-circuit current (r.m.s. value of the possible rated short-circuit current for the system). You will find the current-limiting characteristics for the fuse links in the catalog add-on ET B1 AO 8 BETA Low-Voltage Circuit Protection, Characteristic Curves for Catalog ET B1. For busbar supports with busbars of 12 mm to 20 mm, the distance between the holders of the support spacing should be adapted to suit the bars in the distribution board and should not exceed 20 mm if possible. When using busbars of 2 mm, 30 mm, mm to mm, the distance can also be up to 00 mm. In the case of larger distances, subcarriers must be fitted as increased support spacing reduces the dynamic stability. It is essential to ensure that the permissible current carrying capacity of the individual busbars is not exceeded. A center infeed is required in the limit range. However, the infeed can also be carried out at both ends of the busbar. Diagram of the dynamic short-circuit strength of the busbars 80 D [ka] x 12x n 20 A 30 n A i D : Let-through values (ka) of the LV HRC fuse links, operational class gl/gg with rated current A to 630 A for a prospective short-circuit current I p =120kA. Planning dimensions Distance between busbar support in mm I2_07483a 30x10 30x 20x10 12x10 Let-through current of the fuse links Operating class gl/gg n 630 A n 00 A Busbar dimension mm n 400 A n 31 A Width mm MW NEOZED bus-mounting bases D02 Covers Covers, extra wide Covers, double width DIAZED bus-mounting bases DII Covers Covers, double width DIAZED bus-mounting bases DIII Covers Covers, double width NEOZED bus-mounting switch disconnectors LV HRC fuse switch disconnectors size Number of built-in components that can be mounted Height Width Cutout width D02/63 A SH 241 D02/63 A SH 242 D02/63 A SH 243 DII/2 A SH2 042 DIII/63 A SH2 242 SG7 230 busmounting switch disconnectors D02 mm mm mm (27 mm wide) (36 mm wide) (4 mm wide) (42 mm wide) (7 mm wide) (26.8 mm wide) /8 Siemens ET B1 10/9
9 Siemens AG 9 BETA Protecting SR Busbar Systems Overview Rail-adaptable built-in components, such as NEOZED and DIAZED bus-mounting bases, adapters for modular installation devices, LV HRC fuse switch disconnectors and NEOZED busmounting fuse switch disconnectors are made of glass-fiber reinforced, thermoplastic polyester. The material ensures required mechanical, chemical and electrical properties. Efficient power distribution up to 630 A. There are many ways for users to mount the SR busbar system: 1. Mounting in distribution boards The busbar supports are mounted on longitudinal stays. Once the built-in components have been mounted and connected, the touch protection cover (front cover) protects against accidental contact with live parts. 2. Installation in industrial control cabinets The demand for comprehensive touch protection has generated new solutions: built-in components, such as busbar fuse bases Built-in components have integrated reach-through guards, enable the implementation of cost-effective overall solutions. Previously two optional solutions were provided, which can now be replaced using new technology: the touch protection over base and the respective edges, or touch protection by means of partitions. Overall, increased efficiency and cost savings for the plant manufacturer. With fuse holders for cylindrical fuses, size and for American fuses class CC, they can also be deployed in the international plant engineering sector. In addition, Siemens offers a wide range of UL-approved components for the design of switchgear assemblies in accordance with UL 08 A. For further information, see chapter BETA Devices Approved to UL Standard in Catalog LV For the ultimate in user safety and convenience, we also offer fuse holders and connection modules 16 mm² with screwless terminals I2_13634a $ NEOZED bus-mounting base, 3-pole % DIAZED bus-mounting base, 3-pole & SR bus-mounting fuse holder, 3-pole ( NEOZED bus-mounting switch disconnector, 3-pole ) Connection module, three-phase * Adapter for modular installation devices acc. to DIN LV HRC fuse switch disconnector Benefits The direct contact of the rail-adaptable switching and installation devices on the Cu busbars reduces distribution panels and mounting times, and Compared to conventional installation, the transfer resistance of the connections helps prevent unnecessary temperature rises. New touch-protected built-in components ensure comprehensive touch protection without the previously required partitions. International implementation due to UL-approved components. Enhanced effectiveness and increased safety due to screwless terminals Siemens ET B1 10/9 /9
10 BETA Protecting SR Busbar Systems Siemens AG 9 Built-in components Technical specifications NEOZED SR bus-mounting bases SG6 202 SG6 206 SG6 207 DIAZED SR bus-mounting bases SF6 014 SF6 01 SF6 018 SF6 020 SF6 214 SF6 21 SF6 218 SF6 220 D01 D02 DII DIII Standards IEC 269-3/DIN VDE Rated voltage V AC/DC 400/ /0 Rated frequency Hz 0 Rated current 16 (with NEOZED retaining springs) Rated conditional short-circuit current ka AC 0 0 ka DC 8 8 For fuse links with power losses per phase W Busbar center-to-center clearance mm 3NW NW HG 3NW HG Standards IEC 269-2, UL 12, CSA C22.2 UL 12, CSA C22.2 Approvals U, CSA UL, CSA Sizes Class CC Rated frequency Hz 0/ Max. rated voltage U e IEC/EN VAC UL/CSA VAC 0 0 Max. rated operational current I e (When several devices are used next to each other, it is essential to comply with the rated load factor according to VDE 06, Part 00/EN 439-1, Table 1. IEC/EN A UL/CSA A Utilization categories IEC/EN AC-22B (00 V) AC-21B (690 V, 30 A) UL/CSA Can only be used as fuse holder Can only be used as fuse holder Rated conditional short-circuit current (Type-tested with fuse links, operational class gl/gg) IEC/EN ka 100 (400 V, 00 V, 690 V) -- UL/CSA ka 0 (0 V) For fuse links with power losses per phase W 3 -- Screwless wire connections IEC/EN mm 2 Cu 1. 6 (f) UL/CSA AWG (str) For standalone operation without lateral modules or for group operation with lateral modules 1) In the case of permanent load over 3 A, we recommend the use of SH 26 lateral modules. Please observe EN 439-1, Table 1. SG NW7 430 Standards IEC IEC Approvals VDE , EN 947-3, IEC IEC IEC VDE , EN 947-3, IEC Sizes D01 D02 10 mm 38 mm Rated frequency Hz 0/ 0/ Rated voltage U e VAC VDC Rated insulation voltage U i V Rated impulse withstand voltage U imp kv 6 6 Rated operational current I e A 63 1) Up to 32 Utilization categories AC-23 A (400 V) AC-20 (Type-tested with 3-poled, switchable version) DC-21 B (48 V) 1 pole DC-20 DC-21 B (110 V) 2 pole Rated conditional short-circuit current ka AC 0 0 (Type-tested with fuse links, operational class gl/gg) ka DC 8 -- Permissible power loss of fuse links per phase W. 3 /10 Siemens ET B1 10/9
11 Siemens AG 9 BETA Protecting SR Busbar Systems Built-in components SG NW7 430 Box terminals for wire connection mm 2 Cu 1. 6 (re) Cu 1. 6 (re) mm 2 Cu (f) Cu (f) mm 2 Cu (f+ae) Cu (f+ae) Alarm switches for the display of switching positions 1 CO 1 CO Cable terminals Bottom Bottom Busbar thickness mm Through combination foot for, 10 mm Through combination foot for, 10 mm Selection and ordering data Size Rated current Rated voltage MW DT Order No. Price PU PS*/ P. unit PG Weight approx. A V Unit(s) Unit(s) kg NEOZED SR bus-mounting bases with touch protection, 3P For /10 mm busbars 27 mm wide D B SG mm wide D B SG NEOZED SR bus-mounting bases, 3P, standard version For /10 mm busbars D A SG / NEOZED SR covers for standard version D02 1. A SH / Extra wide, with clearance for wiring D02 2 B SH / With double width For more clearance for wiring D02 3 C SH / DIAZED SR bus-mounting bases with touch protection, 3P For /10 mm busbars For use with DIAZED SR adapter rings DII B SF DIII V AC/DC (acc. to DIN VDE also 690 V AC/0 V DC) 3.2 B SF For use with DIAZED screw adapters DII B SF DIII V AC/DC (acc. to DIN VDE also 690 V AC/0 V DC) 3.2 B SF For NEOZED screw caps, adapter sleeves and fuse links, see chapter "Low-voltage fuse systems, NEOZED fuse systems". * You can order this quantity or a multiple thereof. Siemens ET B1 10/9 /11
12 BETA Protecting SR Busbar Systems Siemens AG 9 Built-in components Size Rated current Rated voltage MW DT Order No. Price PU PS*/ P. unit PG Weight approx. A V Unit(s) Unit(s) kg DIAZED SR bus-mounting bases, 3P standard version For /10 mm busbars For use with DIAZED adapter rings DII B SF / DIII V AC/DC (acc. to DIN VDE also 690 V AC/0 V DC) 3.2 B SF / For use with DIAZED screw adapters DII B SF / DIII V AC/DC (acc. to DIN VDE also 690 V AC/0 V DC) 3.2 B SF / DIAZED SR covers for standard version DII 2.3 B SH / DIII 3.2 B SH / DIAZED SR adapter rings Only for DIAZED SR bus-mounting bases DII 2 C SH / C SH / C SH / C SH / C SH / C SH / DIII 2 C SH C SH C SH C SH C SH C SH C SH / C SH / C SH / SR bus-mounting fuse holders, 3P For /10 mm busbars With screwless terminals For cylindrical fuses, mm U, s A 3NW For UL fuses, class CC u, s A 3NW HG For UL fuses, class CC u, s with LED signal detectors A 3NW HG NEOZED SR bus-mounting switch disconnectors, 3P For /10 mm busbars D02 63* A SG / *For loads > 3 A, use SH 26 lateral modules SR bus-mounting disconnectors, 3P For cylindrical fuses mm For /10 mm busbars A 3NW / For DIAZED screw caps, screw adapters and fuse links, see chapter "Low-voltage fuse systems, DIAZED fuse systems". /12 Siemens ET B1 10/9 * You can order this quantity or a multiple thereof.
13 Siemens AG 9 BETA Protecting SR Busbar Systems Built-in components MW DT Order No. Price PU PS*/ P. unit PG Weight approx. A V Unit(s) Unit(s) kg Auxiliary switches for signaling the switching state of the NEOZED bus-mounting switch disconnectors and disconnectors 1 CO 0. C SH 2 1 1/ Lateral modules For greater heat dissipation for loads > 3 A with NEOZED bus-mounting switch disconnectors 0. C SH 26 1 / Reducers For NEOZED fuse links D01 In SR bus-mounting switch disconnectors C SH / SR LV HRC bus-mounting fuse bases, 3P, size 00 For /10 mm busbars With cover, connections at top Terminals up to 70 mm 2 Rated voltage 690 V With saddle-type terminal A 3NH For additional busbar adapters, see Catalog LV 1. For fuse switch disconnectors, see chapter "Low-voltage fuse systems". Number of support rails (3 mm) Rated current Conductor crosssection Adapters L W U n DT Order No. Price PU PS*/ P. unit PG Weight approx. A mm 2 mm mm V Unit(s) Unit(s) kg Device adapters with top terminal A 8US12 0-RM Device adapters with top connecting cables } 8US12 1-DM } 8US12 61-FM Device adapters with Cage Clamp connection } 8US12 1-CM Device holders for lateral mounting on device adapters of the same length } 8US12 0-AM Connecting plates (2 units required for mounting) } 8US AA Lateral modules for widening device adapters and device holders of the same length A 8US BM * You can order this quantity or a multiple thereof. Siemens ET B1 10/9 /13
14 BETA Protecting SR Busbar Systems Siemens AG 9 Built-in components Dimensional drawings NEOZED SR bus-mounting bases D02/63 A (a = 27 mm, t = bar thickness) D02/63 A (a = 27 mm, b = 0 mm) D02/63 A (a = 36 mm, b = 0 mm) I2_07478a I2_13998 a t a b SG6 202 (t = mm) SG6 206 SG6 207 DIAZED SR bus-mounting bases DII/2 A (a = 42 mm) 33, DIII/63 A (a = 7 mm) DII/2 A (a = 42 mm) DIII/63 A (a = 7 mm) I2_07497 I2_07496 I2_ a t 36 43, 66 a t 36 43, 66 a b SF6 014, SF6 01 (t = mm) SF6 214, SF6 21 (t = mm) SF6 018, SF6 020 (b = 70 mm) SF6 218, SF6 220 (b = 70 mm) /14 Siemens ET B1 10/9
15 Siemens AG 9 BETA Protecting SR Busbar Systems Built-in components NEOZED SR covers SR LV HRC bus-mounting fuse bases, 3P D02/63 A I2_ I2_ I2_0711 I2_07479a SH fold SH fold SH fold 3NH4 02 DIAZED SR covers NEOZED SR bus-mounting switch disconnectors/ SR bus-mounting disconnectors DII/2 A DIII/63 A 27, 31, 19,2 I2_0843 I2_ I2_ ,8 SH2 042 (1-fold: a = 42 mm) SH2 242 (1-fold: a = 7 mm) SG NW7 430 SR bus-mounting fuse holders for cylindrical fuses , I2_ NW7 431, 3NW HG, 3NW HG Siemens ET B1 10/9 /1
16 BETA Protecting SR Busbar Systems Siemens AG 9 Built-in components Device adapters 20 L=10 mm 48 NSE0_ (10) NSE0_00442a 8US12 0-RM07 8US12 1-DM07 L=128 mm NSE0_00443a NSE0_ (10) 24 8US12 61-FM08 8US12 1-CM47 Device holders Lateral modules NSE0_00422a NSE0_ US12 0-AM00 13, 41,7 8US BM00 13,7 Schematics Symbols SG NW7 430 /16 Siemens ET B1 10/9
17 Siemens AG 9 BETA Protecting SR Busbar Systems Mounting components Overview The mounting components enable an enclosed design on a mounting plate. The base, the holders for the edges, the edges, the supports for blanking covers with blanking cover and the end covers form a complete enclosure with degree of protection IP I201_ $ End cover % Base & Edge ( Blanking cover ) Holder Benefits The mounting components enable a closed design for the SR busbar system in any switchgear assembly. The touch protection rating to IP20 means that operation is safe, even for non-specialists. Siemens ET B1 10/9 /17
18 BETA Protecting SR Busbar Systems Siemens AG 9 Mounting components Selection and ordering data Length DT Order No. Price PU PS*/ P. unit PG Weight approx. mm Unit(s) Unit(s) kg Bases Height 230 mm, for 3 busbars 1100 B SH mm, for 4 busbars C SH Blanking covers Mounting on SH3 36 supports for blanking 1000 A SH covers, height 202 mm Edges 17 x 36 mm, for 3 busbars 1100 B SH x 36 mm, for 4 busbars C SH US AC00 SH3 34 Partitions For additional touch protection on systems without bases, slotted mm 1100 C SH End covers For covering free busbar ends L1 L3, for 8US AA01 or A 8US AC US AA01 L1 L3 + PE/N, 4P, for A 8US AB US AA00 (1 pack = 2 units, (1 x right, 1 x left)) For SH3 32 holders Height 230 mm (3P) B SH Height 290 mm (4P or 3P + wiring duct), (1 pack = 2 units, (1 x right, 1x left)) C SH / Holders For edges and partitions SH3 28, SH3 30 and SH3 31 B SH Supports for blanking covers For blanking covers, for busbar mounting (2 units required for each section of blanking cover) B SH / Busbar supports For SR busbar system For busbars with a bar thickness of or 10 mm and a busbar height of 12, 1, 20, 2 or 30 mm L1 L3, 3P, with outer mounting A 8US AA L1 L3, 3P, with inner mounting A 8US AA L1 L3 + PE/N, 4P, with inner mounting A 8US AA /18 Siemens ET B1 10/9 * You can order this quantity or a multiple thereof.
19 Siemens AG 9 BETA Protecting SR Busbar Systems Mounting components Dimensional drawings Blanking cover End cover for busbar supports, lateral I2_06697d I2_07491b I2_07492b 7 78, 7 SH3 37 SH3 33 SH , Edge Edge Partition , I2_0704a I2_070a SH3 28 SH3 30 SH3 31 I2_0706b Holder for edges and partitions Support for blanking covers I2_07488b I2_0613c , SH3 32 SH , Siemens ET B1 10/9 /19
20 BETA Protecting SR Busbar Systems Siemens AG 9 Mounting components Busbar support for SR Busbar support for SR Busbar support for SR A SECTION: A-A A SECTION: A-A L1 6, 21 30, , L 2 L A NSE0_0167a 49, 20 A 20 NSE0_0168a 49, PE N 20 I2_07477a US AA01 8US AA01 8US AA00 /20 Siemens ET B1 10/9
SR60 Busbar System 2/1 2/2. General Data. 2/3 Busbar routing. 2/7 Mounting components. 2/13 Accessories
/ SR0 Busbar System General Data / Busbar routing / Mounting components / Accessories / SR0 Busbar System General Data Overview The SR0 busbar system is a modular system for busbars, for installation in
More informationSiemens AG Busbar Systems SENTRON. Configuration. Edition Manual. Answers for infrastructure and cities.
Busbar Systems SENTRON Configuration Manual Edition 2014 Answers for infrastructure and cities. Busbar Systems 2 Introduction 3 General data 8US 40 mm busbar systems 7 Introduction 8 Basic assemblies
More informationBusbar Systems. 10/2 Introduction. 10/3 General data. 40 mm Busbar Systems 10/6 Introduction 10/7 Base assemblies up to 400 A
Siemens AG 20 Busbar Systems /2 Introduction /3 General data 40 mm Busbar Systems /6 Introduction /7 Base assemblies up to 400 A mm Busbar Systems /8 Introduction /9 Base assemblies up to 630 A /13 Base
More informationSR60 Busbar System 2/1. 2/2 Busbar routing. 2/3 Mounting components. 2/6 Accessories
SR60 Busbar System 2 2/2 Busbar routing 2/3 Mounting components 2/6 Accessories 2/1 SR60 Busbar System Busbar routing SR60 Busbar System Dimensions Order No. Price PG Weight PS*/ W x H x D mm mm mm 1 item
More informationSENTRON SIVACON ALPHA
SENTRON SIVACON ALPHA Low-Voltage Power Distribution and Electrical Installation Technology Catalog Extract LV 10 Edition 04/2018 siemens.com/lowvoltage Related catalogs Low-Voltage Power Distribution
More informationSENTRON SIVACON ALPHA
SENTRON SIVACON ALPHA Low-Voltage Power Distribution and Electrical Installation Technology Catalog Extract LV 10 Edition 10/2018 siemens.com/lowvoltage Related catalogs Low-Voltage Power Distribution
More informationMiniature Circuit Breakers for Railway Applications
Siemens AG 00 for Railway Applications BETA Low-Voltage Circuit Protection The miniature circuit breakers are used in fixed railway systems and rolling stock for protecting system components against overcurrent
More informationOvervoltage Protection Devices
Siemens AG 2010 Overvoltage Protection Devices /2 Introduction /3 Lightning Arresters, Type 1 /5 Combination Surge Arresters, Type 1 and Type 2 /7 Surge Arresters, Type 2 /11 Surge Arresters, Type 3 /12
More informationComponents for Distribution Systems
Components for Distribution Systems /2 Introduction Busbar adapter systems /4 General data /7 40 mm system / 60 mm system /12 Accessories /14 Project planning aids Door-coupling rotary mechanisms /23 General
More informationSiemens AG SENTRON 3NJ4, 3NJ5 In-Line Fuse Switch Disconnectors up to 2000 A
Switch Disconnectors Introduction Overview All key product features at a glance Compliant with IEC/EN 60439-1, IEC/EN 6094-3 Voltage levels up to 690 V AC Rated operational current from 160 A to 2000 A
More informationALPHA SIMBOX Small Distribution Boards
ALPHA SIMBOX Small Distribution Boards /2 Introduction /3 Introduction /4 Flush-mounting and hollow-wall distribution boards /5 Surface-mounting and hood-type distribution boards /6 Accessories /7 Dimensional
More informationSiemens AG KD Switch Disconnectors SENTRON. Edition December Answers for infrastructure and cities.
KD Switch Disconnectors SENTRON Edition December 01 Answers for infrastructure and cities. Related catalogs Low-Voltage Power Distribution and LV 10 Electrical Installation Technology SENTRON SIVACON ALPHA
More informationIssued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog
Issued February 2011 DATA SHEET 5SX2 MCB Based on Siemens Industrial Control Catalog General Data Trip characteristics Tripping characteristics acc. to EN 60 898 Tripping characteristic A, -5 Type A characteristic
More informationSiemens AG RA6 Fuseless Compact Starters. Catalog News LV 1 N April 2008 SIRIUS.
3RA Fuseless Compact Starters Catalog News LV 1 N April 2008 SIRIUS www.siemens.com/lowvoltage 3RA Fuseless Compact Starters General data Overview 3RA fuseless compact starters and infeed system for 3RA
More information8WH5 Combination Plug-In Terminals
8WH Combination Plug-In Terminals /2 Introduction / 8WH through-type terminals 1) /7 8WH hybrid through-type terminals with ipo connection /8 8WH9 plugs 1) 1) Also available as a PE version More technical
More informationOvervoltage Protection Devices
Siemens AG 2014 Overvoltage Protection Devices /2 Introduction /3 5SD7 lightning arresters, type 1 /5 5SD7 combination surge arresters, type 1 and type 2 /7 5SD7 combination surge arresters, type 1 / type
More informationApplication Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole) I cs 7,5 ka
DATASHEET - FAZ-C16/1 Miniature circuit breaker (MCB), 16A, 1p, C-Char, AC Part no. FAZ-C16/1 Catalog No. 278561 Eaton Catalog No. FAZ-C16/1 EL-Nummer 0001695154 (Norway) Similar to illustration Delivery
More informationOvervoltage Protection Devices
Overvoltage Protection Devices /2 Introduction /3 5SD7 lightning arresters, type 1 /5 5SD7 combination surge arresters, type 1 and type 2 /7 5SD7 surge arresters, type 2 /10 5SD7 surge arresters, type
More informationOvervoltage Protection Devices
Siemens AG 201 /2 Introduction /3 5SD7 lightning arresters, type 1 /5 5SD7 combination surge arresters, type 1 + type 2 /7 5SD7 combination surge arresters, type 1 / type 2 /9 5SD7 surge arresters, type
More informationDistribution Systems ALPHA. Answers for infrastructure and cities. Edition Catalog LV 51
Distribution Systems ALPHA Catalog LV 51 Edition 2013 Answers for infrastructure and cities. Related catalogs Low-Voltage Power Distribution and LV 10.1 Electrical Installation Technology SENTRON Protection,
More informationFast Bus Busbar System
Busbar System Industrial Controls Product Catalog 2017 Section c o n t e n t s Fast Bus busbar adapter system mm system Page Selection and ordering data Busbar holders /9 Fast Bus adapter shoes /11 Incoming
More informationApplication Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole)
DATASHEET - FAZ-C10/2 Miniature circuit breaker (MCB), 10A, 2p, C-Char, AC Similar to illustration Part no. FAZ-C10/2 Catalog No. 278756 Eaton Catalog No. FAZ-C10/2 EL-Nummer 1695166 (Norway) Delivery
More informationSwitches 6/1. 6/4 Introduction. 6/5 5TE8 control switches. 6/7 5TE4 8 pushbuttons. 6/9 5TE8 On/Off switches. 6/11 5TE1 switch disconnectors
6/4 Introduction 6/5 5TE8 control switches 6/7 5TE4 8 pushbuttons 6/9 5TE8 On/Off switches 4 6/11 5TE1 switch disconnectors 6 6/1 Switch to manual? Wherever electrical systems need to be switched on or
More informationApplication Switchgear for industrial and advanced commercial applications. U e V AC 277/480 Y V DC 60
DATASHEET - FAZ-C5/2-RT Miniature circuit breaker (MCB), 5A, 2p, C-Char, AC Part no. FAZ-C5/2-RT Catalog No. 102203 Eaton Catalog No. FAZ-C5/2-RT EL-Nummer 1691799 (Norway) Similar to illustration Delivery
More informationProtection Equipment
Protection Equipment Price groups 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J, 143, 401 /2 Introduction Motor starter protectors/ circuit breakers SIRIUS 3RV2 motor starter protectors up to 40 A / General data
More informationOvervoltage Protection Devices
Siemens AG 2013 Overvoltage Protection Devices /2 Introduction /3 5SD7 lightning arresters, type 1 /5 5SD7 combination surge arresters, type 1 and type 2 /7 5SD7 surge arresters, type 2 /10 5SD7 surge
More information5SL Miniature Circuit Breakers
5SL Miniature Circuit Breakers BETA Low-Voltage Circuit Protection The new 5SL miniature circuit breaker is intended for use up to ka. The devices have the system features characteristic of all Siemens
More informationControls Solid-State Switching Devices
Siemens AG 27 Controls Solid-State Switching Devices /2 Introduction Solid-State Switching Devices /3 General data Solid-State Relays /6 General data /7 3RF21 solid-state relays, single-phase, 22.5 mm
More informationFast Bus Fast Bus Busbar System
Fast Bus Busbar System Contents Fast Bus busbar adapter system mm system Page Selection and ordering data Busbar holders /9 Fast Bus adapter shoes /11 Incoming supply terminals /6 Copper busbar /6 Busbar
More information1/2 Introduction. SIMBOX LC 1/7 Introduction 1/8 Flush-mounting and surfacemounting. 1/9 Dimensional drawings
Siemens AG 200 ALPHA SIMBOX Small Distribution Boards /2 Introduction /2 Introduction /3 Flush-mounting and hollow-wall distribution boards /4 Hood-type distribution boards /5 Accessories /6 Dimensional
More informationSwitch Disconnectors, Main and EMERGENCY-STOP Switches
General data Overview Siemens G 2010 1 2 3 NSE0_01931b 4 5 6 7 1 uxiliary switch (3SB for 3K; 3KX for 3KE) 2 IP20 terminal cover (Operator side) 3 3K switch disconnector 4 rcing contacts (only for 3KE)
More informationST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077
MINIATURE CIRCUIT BREAKERS ST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077 The ST 200 M miniature circuit breaker provides supplementary
More information3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017
3RM1 Hybrid Starters Industrial Controls Product Catalog 2017 Section contents 3RM1 Compact - Hybrid Starters Overview /2 General Data /3 Selection and ordering data /4 Accessories /5 - /9 Technical Data
More informationMotor-protective circuit-breaker, 3p, Ir=16-25A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A
DATASHEET - PKZM4-25 Delivery program Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection Part no. PKZM4-25 Catalog No. 222352 Eaton Catalog No. XTPR025DC1NL EL-Nummer 0004355158 (Norway)
More informationALPHA AS NF Universal Modular Distribution Boards
ALPHA AS NF Universal Modular Distribution Boards ALPHA Distribution Boards ALPHA AS universal modular distribution boards provide you with the best framework for currents up to 800 A. The comprehensive
More informationFAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview
FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview Supplementary Protectors / Miniature Circuit Breakers Page System overview 10/003 10/001 Supplementary protectors
More informationCombined RCD/MCB Devices FRBmM, 1+N-pole
Combined RCD/MCB Devices FRBmM, 1+N-pole SG13711 High-quality residual current device / miniature circuit breaker combination, line voltage-independent Contact position indicator red - green Fault current
More informationDisconnect Switches. Safe Switching and Disconnecting
IB105-UK_U1_U4_Pfade.indd 2-3 14.04.2005, 16:51:30 Disconnect Switches Safe Switching and Disconnecting Disconnect Switches from Salzer are hand-operated switchgear for main circuits and are offered as
More information1492-SP Supplementary Protectors
Dual terminals provide wiring/bus bar flexibility and clamp from both sides to improve connection reliability Approval marks are easily visible on dome Terminal design helps prevent wiring misses Scratch-
More informationTeSys IEC Contactors and Overload Relays
TeSys IEC Contactors and Overload Relays Making High-Fault Short-Circuit Current Ratings Simple Schneider Electric is an industry leader in IEC contactors and overload relays, and is recognized as the
More informationALPHA Small Distribution Boards SIMBOX 63/SIMBOX WP
ALPHA Small Distribution Boards SIMBOX 63/SIMBOX WP SIMBOX 63 /4 Introduction /5 Flush mounting distribution boards /6 Hollow-wall distribution boards /7 Surface mounting distribution boards /7 Hood-type
More informationDescription Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA
Delivery program Contactor relay, 3N/O+1N/C, DC current Part no. DILA-31(24VDC) Catalog No. 276379 Eaton Catalog No. XTRE10B31TD EL-Nummer 4130206 (Norway) Product range DILA relays Application Contactor
More informationFor Sales and Support call KMParts.com (866)
Overcurrentswitch,5A,1p,B-Char,AC Partno. FAZ-B5/1 Articleno. 278528 CatalogNo. FAZ-B5/1 Similar to illustration Deliveryprogram Basic function Miniature circuit breakers Number of poles 1 pole Tripping
More informationLoad Feeders and Motor Starters for Use in the Control Cabinet
Load Feeders and Motor Starters for Use in the Control Cabinet Price groups 12W, 14O, 230, 241, 250, 260, 41B, 41D, 41E, 41L, 42C, 42D, 42F, 471, 4N1, 5K1, 5K2, 5N2, 764, 15, 16 /2 Introduction SIRIUS
More informationSiemens AG 2017 SENTRON. 3LD Main Control and EMERGENCY-STOP Switches. Catalog Extract LV 10. Edition 10/2017. siemens.com/switching-devices
Siemens AG 201 SENTRON 3LD Main Control and EMERGENCY-STOP Switches Catalog Extract LV 10 Edition 10/201 siemens.com/switching-devices Siemens AG 201 Related catalogs Low-Voltage Power Distribution and
More informationSafety relay emergency stop/protective door, 24VDC/AC, 4 enabling paths
DATASHEET - ESR5-NO-41-24VAC-DC Safety relay emergency stop/protective door, 24VDC/AC, 4 enabling paths Part no. ESR5-NO-41-24VAC-DC Catalog No. 118701 EL-Nummer (Norway) 0004133317 Delivery program Product
More informationSafety relay emergency stop/protective door, 230VAC, 3 enabling paths
DATASHEET - ESR5-NO-31-230VAC Safety relay emergency stop/protective door, 230VAC, 3 enabling paths Part no. ESR5-NO-31-230VAC Catalog No. 119380 EL-Nummer (Norway) 4133320 Delivery program Product range
More informationSIRCO Load break switches for power distribution from 125 to 5000 A
The solution for Load break switches sirco_456_a_1_cat > Main switchboard > Distribution panel > Emergency breaking > Network coupling > Local safety breaking sirco-ac_001_a_1_cat SIRCO 3 x 250 A direct
More informationUL 489 DIN Rail Miniature Circuit Breakers
UL 489 DIN Rail Miniature Circuit Breakers Product Overview................................................ 2 Product Selection................................................ 4 Accessories.....................................................
More informationMiniaturecircuitbreaker(MCB),16A,3p,B-Char,AC. Application Switchgear for industrial and advanced commercial applications.
Miniaturecircuitbreaker(MCB),16A,3p,B-Char,AC Similar to illustration Partno. FAZ-B16/3 CatalogNo. 278847 EatonCatalogNo. FAZ-B16/3 EL-Nummer 1695123 Deliveryprogram Basic function Miniature circuit-breakers
More informationdv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2
dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Operating Instructions Safety information 1 General 2 Mechanical installation 3 Electrical
More informationApplication Instantaneous release response current 5-10 x In. Switching capacity Switching Capacity 15 ka (IEC/EN ) U e V AC 230/400
Overcurrentswitch,10A,3p,C-Char,AC Partno. FAZ-C10/3 Articleno. 278869 CatalogNo. FAZ-C10/3 Similar to illustration Deliveryprogramme Product range FAZ Application Instantaneous release response current
More informationSafety relay emergency stop/protective door, 24VDC/AC, 3 enabling paths
DATASHEET - ESR5-NO-31-24VAC-DC Delivery program Safety relay emergency stop/protective door, 24VDC/AC, 3 enabling paths Part no. ESR5-NO-31-24VAC-DC Catalog No. 118702 EL-Nummer (Norway) 4133318 Product
More informationUL 489 DIN Rail Miniature Circuit Breakers
UL 9 DIN Rail Miniature Circuit Breakers Product Overview................................................ Product Selection................................................ Accessories.....................................................
More informationSafety relay emergency stop/protective door, 24V-230VDC/AC, 3 enabling paths
DATASHEET - ESR5-NO-31-AC-DC Delivery program Safety relay emergency stop/protective door, 24V-230VDC/AC, 3 enabling paths Part no. ESR5-NO-31-AC-DC Catalog No. 118704 Eaton Catalog No. ESR5-NO-31-AC-DC
More informationSolid-State Switching Devices
Controls Solid-State Switching Devices /2 Introduction Solid-State Switching Devices /3 General data Solid-State Switching Devices for Resistive Loads /5 General data Solid-State Relays /7 General data
More informationVAL-CP-1S-175. Extract from the online catalog. Order No.:
Extract from the online catalog VAL-CP-1S-175 Order No.: 2859479 Pluggable type 2 arrester (surge arrester) for 1-phase current supply networks with separate N and PE (3-conductor system: L1, N, PE), with
More informationMULTI-POLE PHOTOVOLTAIC SYSTEMS. COMPACT and MODULAR Housing
MULTI-POLE Lightning Current and Surge Arresters for PHOTOVOLTAIC SYSTEMS Class I / (B+C) and Class II / (C) COMPACT and MODULAR Housing 44 PV ISPRO BS(R) 12,5 The PV ISPRO BS(R) 12,5 series of over voltage
More informationSENTRON SIVACON ALPHA
SENTRON SIVACON ALPHA Low-Voltage Power Distribution and Electrical Installation Technology Catalog Extract LV 10 Edition 10/2018 siemens.com/lowvoltage Related catalogs Low-Voltage Power Distribution
More informationOVERLOAD RELAYS POWER & ACTUATION PROVEN. series
POWER & ACTUATION OVERLOAD RELAYS series Need reliable, accurate overload and phase-loss protection for your motors? c3controls Series Bimetallic Overload Relays provide unmatched protection and can be
More informationSolid-State Contactors
Solid-state contactors for switching motors The solid-state contactors for switching motors are intended for frequently switching on and off three-phase current operating mechanisms up to 7.5 kw and reversing
More informationVAL-CP-3S-350. Extract from the online catalog. Order No.:
Extract from the online catalog VAL-CP-3S-350 Order No.: 2859521 Commercial data EAN 4017918977610 Pack 1 Pcs. Customs tariff 85363030 Weight/Piece 388.83 g Product key J020 Catalog page information Page
More informationProduct Details. Contents. Features and Mounting Options for SUNNY STRING-MONITOR SSM24-11
Technical Information Product Details Features and Mounting Options for SUNNY STRING-MONITOR SSM24-11 Contents The Sunny String Monitor SSM24 11 is specifically designed for monitoring large PV generators.
More informationQUINT-PS/1AC/24DC/10. Extract from the online catalog. Order No.:
Extract from the online catalog QUINT-PS/1AC/24DC/10 Order No.: 2866763 DIN rail power supply unit 24 V DC/10 A, primary-switched mode, 1- phase. The SFB technology (Selective Fusebreaking Technology)
More informationSITOP in the SIMATIC Design
Siemens AG 2017 /2 Introduction /3 1-phase, 24 V DC (for S7-300 and ET 200M) /9 1-phase, 24 V DC (for S7-1200) /11 1-phase, 24 V DC (for S7-1500 and ET 200MP) /14 3-phase, 24 V DC (ET 200pro) Siemens KT
More information1.3. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZS Circuit Breaker. UL 1077 DIN Rail Supplementary Protectors
. Miniature Circuit Breakers and Supplementary Protectors UL 077 DIN Rail Supplementary Protectors WMZS Circuit Breakers Contents Description WMZS Circuit Breaker Standards and Certifications................
More informationLightning and Surge Arresters
Lightning and Surge Arresters 5/4 Product overview 5/5 Lightning arresters, requirement category I (B) 5/6 Combined arresters, requirement category I (B) and II (C) 5/7 Single-pole surge arrester, requirement
More informationUL 489 Cable-In / Cable-Out Branch Circuit Breaker
Product Overview UL 9 Cable-In / Cable-Out Branch Circuit Breaker PRODUCT OVERVIEW Optimum and Efficient Protection Features Complete range of UL 9 listed DIN rail mounted miniature circuit breakers up
More informationRiLine Compact The smart power distribution system
RiLine Compact The smart power distribution system 2 Power distribution in a confined space Rittal are the leading suppliers of reliable power distribution and backup systems for controlgear. The new RiLine
More informationQUINT-DC-UPS/24DC/10. Extract from the online catalog. Order No.:
Extract from the online catalog QUINT-DC-UPS/24DC/10 Order No.: 2866226 Uninterruptible power supply 24 V DC/10 A, with integrated 1.3 Ah battery module. In the download area, there is a clearly arranged
More informationQUINT-DC-UPS/24DC/40. Extract from the online catalog. Order No.:
Extract from the online catalog QUINT-DC-UPS/24DC/40 Order No.: 2866242 Uninterruptible power supply 24 V/40 A. In the download area, there is a clearly arranged selection table available with load currents
More informationENERGY SAFELY SWITCHED SWITCHGEAR. BUSBAR SYSTEM 60 mm
ENERGY SAFELY SWITCHED SWITCHGEAR BUSBAR SYSTEM 60 mm SWITCHGEAR ENERGY safely switched About Grupa Apator Who we are? Grupa Apator is a dynamic Polish capital group, it currently includes 14 companies
More informationQUINT-PS/ 1AC/24DC/ 5
Extract from the online catalog QUINT-PS/ 1AC/24DC/ 5 Order No.: 2866750 DIN rail power supply unit 24 V DC/5 A, primary switched-mode, 1- phase. The SFB technology (Selective Fuse Breaking Technology)
More information63 to 125 A. Functions. Conformity standards. General characteristics. Changeover switches SIRCO VM1 changeover switches.
comut_004_a_1_cat Changeover switches switches 63 to 125 A switches are manually operated three or four pole switches. They provide, source inversion or switching under load between two low voltage power
More informationIndustrial Controls Product Catalog RA64 / 3RA65 up to 32 A for mounting rail, surface,
Combination Starters Industrial Controls Product Catalog 2017 Section c o n t e n t s Self Protected Motor Starters per UL 508 Type E 3RA6 3RA61 / 3RA62 up to 32 A for mounting rail, surface, comb busbar,
More informationUK 5-HESILA 250. Extract from the online catalog. Order No.:
Extract from the online catalog UK 5-HESILA 250 Order No.: 3004142 The illustration shows version UK 5-HESI Fuse terminal block for cartridge fuse insert, cross section: 0.2-4 mm², AWG: 26-10, width: 8.2
More informationResidual Current Devices. Residual Current Devices FRCmM-NA according to UL1053 & IEC/EN 61008
Residual Current Devices FRCmM-NA according to UL1053 & IEC/EN 61008 Wide range of compact types of RCDs serving as fault-current and additional protection according to UL1053 & IEC/EN 61008 standards,
More informationMonitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064
Monitoring technique VARIMETER Voltage relay MK 9064N, MH 9064 0269462 Your Advantages Preventive maintenance For better productivity Quicker fault locating Precise and reliable Min-, Max. value or window
More informationDatasheet - SRB 402EM-24V
Print - Create PDF - Create EXCEL file 20.04.2011-18:31:35h Datasheet - SRB 402EM-24V Output expanders / SRB 402EM Expander module for contact expansion 4 safety contacts, STOP 0 2 Signalling outputs (Minor
More informationApproved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules.
Motor Protection Circuit Breaker (MPCB) J7MN MPCB system (motor protection CLSS 0) Rotary and switch types Rated operational current = 2, 25, 50 and 00 Switching capacity up to 2.5 = 00 k/400 V Fixed short-circuit
More informationMotor protection relays
Thermal overload relays for currents between 0.09 and 420A Electronic thermal overload relays for currents between 0.4 and A Electronic thermal overload relays with selectable tripping class: 5--20-30
More informationWEG Contactors - CWM and CWME Series
Inside (877) 789 Fax () 87 WEG Contactors CWM and CWME Series International () 07 The CWM generalpurpose contactor line has been designed taking into consideration industrial duty and reliability in mind.
More informationCS8 Industrial Control Relays
CS8 Industrial Control Relays Despite increasing complexity, control systems and installations must become increasingly compact. And the CS8 Miniature Relay System packs maximum performance into minimum
More informationMonitoring Relays. 3UG Monitoring Relays for Electrical and Additional Measurements. Line monitoring 7/61. Overview
Siemens AG 200 Monitoring Relays Line monitoring Overview Solid-state line monitoring relays provide maximum protection for mobile machines and plants or for unstable networks. Network and voltage faults
More informationBasic Efficiency. NH Fuse-Bases 3-pole. NH Fuse-Bases up to 1500 V. NH Fuse-Bases 1-pole. NH Fuse-Bases, SILAS
Basic Efficiency up to 1500 V 1-pole 3-pole, SILAS MM: Bild angeben Content 690 V AC for baseplate, busbar and supporting rail mounting 58 Accessories 60 Technical Data see page 63 NU System The EFEN successfully
More informationComplete UL/CSA Disconnect Switch Kits
Product Selection Complete UL/CSA Disconnect Switch Kits Includes disconnect switch, operating handle with defeater mechanism and operating shaft, NFPA handle, auxiliary contacts, and padlock attachment.
More informationAThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A.
www.moeller.co.uk Mini Panel Board Cost-effective, space-saving board up to 400A Product Catalogue and Selection Guide Mini Panel Board Miniature Circuit Breakers Moulded Case Circuit Breakers XBoard Consumer
More informationMiniature Circuit Breakers and Supplementary Protectors. Contents
. Optimum and Efficient Protection for Every Application Product Overview Features Optimum product quality, tested reliability and safety stand for best protection of personnel, installations and plant.
More informationDetails of the Han-Terminal block connector Han D AV Han D AV Distributor Han E AV Han ES AV
Contents -Terminal Block Connectors Page Details of the -Terminal block connector........................ 08.02 D................................................... 08.10 D Distributor...........................................
More information4 COMBINATION SIRIUS. SIRIUS 3RA6 Compact Starters 4/2. General data
Combination Starters Industrial Controls Product Catalog 2019 Section contents Self Protected Motor Starters per UL 508 Type E RA6 RA61 / RA62 up to 2 A for mounting rail, surface, comb busbar, infeed
More informationUTME 6. Extract from the online catalog. Order No.:
Extract from the online catalog UTME 6 Order No.: 3047400 Test disconnect terminal block, Connection method: Screw connection, Cross section: 0.2 mm² - 10 mm², AWG: 24-8, Width: 8.2 mm, Color: gray, Mounting
More informationLightning and Surge Arresters
/ Lightning and Surge Arresters Product overview /3 Introduction /6 Lightning arresters, requirement category I (B) /8 Combination arresters, requirement category I (B) and II (C) /0 Single-pole surge
More informationThermal-Magnetic Circuit Breaker 2216-S
Thermal-Magnetic Circuit Breaker 226-S Description One and two pole thermal-magnetic circuit breaker in compact design with slide actuator, trip-free mechanism, various trip characteristics and optional
More informationLoad Feeders, Motor Starters and Soft Starters
Load Feeders, Motor Starters and Soft Starters Catalog Technical Information 3RA Fuseless Compact Starters /2 General data /2 - Overview /3 - Benefits 3RA1, 3RA2 Compact Starters /4 3RA1 direct-on-line
More informationClose Protection from Moeller. miniature branch circuit breakers miniature supplementary protectors
Close Protection from Moeller miniature branch circuit breakers miniature supplementary protectors FAZ branch circuit breakers General Information... Selection Tables Trip Characteristic C - Box terminals...
More informationZelio Relay - plug-in relays
Presentation Presentation offer the advantages of compact size and modular design: their slim width ( mm) saves space when mounting on a rail at the back of an enclosure. RSL relays are available in two
More informationSINAMICS. SINAMICS G120P dv/dt filter plus Voltage Peak Limiter. Safety information 1. General. Mechanical installation. Electrical installation 4
Safety information 1 General 2 SINAMICS SINAMICS G120P dv/dt filter plus Voltage Peak Limiter Operating Instructions Mechanical installation 3 Electrical installation 4 Maintenance and servicing 5 Technical
More informationModular switch disconnectors and modular change-over switches
Modular switch disconnectors and modular change-over switches Modular switch disconnectors and modular change-over switches The new generation of modular switch disconnectors is guarantee of reliability
More informationSIVACON 8MC, 8MF Cubicle Systems
SIVACON 8MC, 8MF Cubicle Systems /2 Introduction /3 8MC System Cubicles 1) /4 8MF System Cubicles 1) /5 Accessories Technical Information can be found at www.siemens.com/lowvoltage/support under Product
More informationSafety switches with separate actuator
Safety switches with separate actuator Selection diagram VF KEYD VF KEYD1 VF KEYD VF KEYD VF KEYD5 VF KEYD6 VF KEYD7 VF KEYD8 VF KEYD10 VF KEYD11 ACTUATORS FR FX FK FW 5 6 7 11 1 14 NC NC snap action snap
More information