Bulletin 2707 DTAM Plus Operator Interface Product Data
|
|
- Noreen Richard
- 5 years ago
- Views:
Transcription
1 A B Product Data Overview The DTAM Plus devices offer a highly functional operator interface to both Allen-Bradley PLC and SLC processors. This proven interface provides operators with the convenience and flexibility needed to monitor and manipulate process data from the plant floor. Connect the DTAM Plus to the SLC family of processors via DH8 network or point-to-point modes. You can also communicate remote I/O via a -SN subscanner. The PLC- family of processors can communicate via remote I/O or DF through Channel 0 RS-/RS-. Just a few features and benefits: 8K or 0K Memory Option Supports approximately 0 or screens of data. Screens display data table information, show alarm conditions and prompt an operator through a series of tasks. Monitors Continuous Changes in Process Data Alarm screens allow the operator to monitor critical areas of the data table, comparing actual data to preset limits. When an alarm condition occurs the operator is prompted to take immediate action. Recipe Function Allows an operator to modify blocks of data quickly. Data can be downloaded to a maximum of 0 non-sequential register addresses per screen. Multiple screens can be linked as part of one recipe. Available with an LCD or VFD Display Both display types feature a line x 0 character display window providing high reliability and superior readability in all light conditions. ASCII Input Capability Allows ASCII data input, such as bar code data, through the optional RS- printer port. Ability to Write the Screen Number back to the PLC Allows the PLC to know at all times where the user is in the menu structure.
2 DTAM Plus Options Various options are available when ordering the DTAM Plus. For example, the DTAM Plus is available with 8K or 0K memory, with backlit LCD (Liquid Crystal Display) or VFD (Vacuum Fluorescent Display) window, two power supply options, and a standard printer port and real time clock on 0K memory units. The table below lists the different variations of the DTAM Plus, as well as accessory items: RS-8 / RS- Versions Catalog Number 0-L8P 0-L8P 0-L0P 0-L0P 0-V0P 0-V0P 0-V0PN Description ➀ LCD Display, 8K Memory, P Power Supply LCD Display, 8K Memory, P Power Supply LCD Display, 0K Memory, Printer Port, Real Time Clock, P Power Supply LCD Display, 0K Memory, Printer Port, Real Time Clock, P Power Supply VFD Display, 0K Memory, Printer Port, Real Time Clock, P Power Supply VFD Display, 0K Memory, Printer Port, Real Time Clock, P Power Supply VFD Display, 0K Memory, Printer Port, Real Time Clock, P Power Supply NEMA Type X Rating (Indoor Use Only) ➀ See Specifications for voltage ranges of P and P Power Supplies. Remote I/O Versions Catalog Number 0-L8PR 0-L8PR 0-L0PR 0-L0PR 0-V0PR 0-V0PR 0-V0PNR Description ➀ LCD Display, 8K Memory, P Power Supply ➁ LCD Display, 8K Memory, P Power Supply ➁ LCD Display, 0K Memory, Printer Port, Real Time Clock, P Power Supply ➂ LCD Display, 0K Memory, Printer Port, Real Time Clock, P Power Supply ➂ VFD Display, 0K Memory, Printer Port, Real Time Clock, P Power Supply ➂ VFD Display, 0K Memory, Printer Port, Real Time Clock, P Power Supply ➂ VFD Display, 0K Memory, Printer Port, Real Time Clock, P Power Supply NEMA Type X Rating (Indoor Use Only) ➂ ➀ See Specifications for voltage ranges of P and P Power Supplies. ➁ Has selectable RS-8 / RS- port for uploading and downloading application files or firmware upgrades. ➂ Printer port is also used for uploading and downloading application files or firmware upgrades. Accessories Catalog Number 0-NC 0-NC 0-NC 0-NC 0-NC 0-NC6 0-NP Cable, DH8 Network Interface Description Cable, RS-C Program Upload/Download Cable, DF RS-C Interface Cable, DF RS- Interface Cable, RS-8 Upload/Download Cable, Bar Code Interface, connects to Allen-Bradley bar code scanners (Catalog No. -G-D, -G6-D) Offline Software Development Package
3 Offline Software Development Package (Catalog No. 0-NP) Use the Offline Software Development Package (Catalog No. 0-NP) to create application screens for the DTAM Plus or DTAM Micro. Use this software to: create data display, bar graph, data entry and alarm screens create menu and submenu screens setup monitoring of data table addresses define printer forms upgrade operating systems (firmware) set configuration parameters for both DTAM Plus or DTAM Micro operator interfaces This software package is available on a / inch (0K) disk and runs on IBM AT or a compatible system with a minimum of 60K RAM. Application screens are developed in a flow chart manner and then linked by the user to facilitate a logical flow of data displays or operator prompts. Easy to understand menu prompts guide the user through the programming steps. For more details on the Offline Programming Software, refer to Publication User-created application programs are easily downloaded to the communications port of the DTAM Plus using RS-8 or RS-. Programs can also be downloaded via the printer port on 0K memory units. Programs are downloaded with the applicable operating system for proper operation with the SLC processor (AB DH8), the 6-BAS module (AB BASIC), -SN Subscanner (Remote I/O) or a PLC (PLC- DF) or (Remote I/O).
4 Hardware Features The DTAM Plus is housed in an aluminum case designed for flush mounting in harsh industrial environments. Gasketing is provided to meet NEMA Type requirements (indoor use only). The NEMA Type X version has a type 6 stainless steel front plate. The front panel of the DTAM Plus is a sealed unit with a line x 0 character display window, LED indicators, and tactile feedback keys. (The VFD version has keys). LED Indicator LED Indicator Display Window MAIN MENU PREV MENU PREV NEXT LED Indicator F Y N 6 EXP 8 9 CE +/ 0 Communication Port Optional Printer Port LCD or VFD Display The line x 0 character display of the DTAM Plus uses either a high contrast Liquid Crystal Display (LCD) with LED backlighting or a Vacuum Fluorescent Display (VFD) to provide high reliability and superior readability in all light conditions. On LCD displays both the contrast and backlight levels are keypad adjustable. Only the brightness is adjustable on the VFD displays. Dimensions - See Page 6.
5 Communications - RS-8 / RS- Versions RS-8 / Port Power Connector RS-8 / Port with Printer Port Power Connector RS-8 / RS- Connector (9 Pin Female) Printer Port RS- Connector (9 Pin Male) Communication Port RS-8 / RS- Connector (9 Pin Female) The configurable communications port of the DTAM Plus supports RS-8 or RS-C. RS-8 communications permit the DTAM Plus to communicate with SLC processors over the Allen-Bradley DH8 network, existing as one of the available nodes. RS-8 also supports point-to-point DH8 communication to either an SLC 00 processor, or to the 6-BAS Module. Communication via the 6-BAS module provides direct backplane communication and faster data throughput. RS-C communications are used to communicate point-to-point DF to Channel 0 of the PLC- processors. RS-C communications can also be used to download/upload DTAM Plus application programs, or for using the DTAM Plus in TERMINAL mode. The DTAM Plus supports the following parameters for RS-8 and RS-C communications: RS-8 and RS-C Communications Parameters Options Baud Rate 00, 00, 00, 800, 9600, 900, 800 Data Bits or 8 Parity Odd, Even, None The DTAM Plus supports RS- with a PLC- (DF protocol) when the communications port is set to RS-8. DF Communications Parameters Options Protocol DF Full-Duplex Error Detect CRC Baud Rate 00, 00, 00, 800, 9600, 900 (Default-9600) Parity None or Even (Default = Even) Control Line Operation No Handshaking Stop Bits
6 Communications - Remote I/O Versions Remote I/O With Printer Port Remote I/O With RS-8 / RS- Communication Port Power Connector Power Connector Printer Port RS- Connector (9 Pin Male) Remote I/O Connector (Terminal Block) Remote I/O Connector (Terminal Block) RS-8 / RS- Connector (9 Pin Female) Remote I/O versions of the DTAM Plus support direct links to a PLC scanner or subscanner module. The DTAM Plus appears to the PLC as a standard I/O rack. Remote I/O Communications Parameters Options Baud Rate.6K,.K, 0.K Rack Size /, /, /, Full Remote I/O with Printer Port (0K Units only) On Remote I/O versions with a printer port, application files are downloaded and uploaded through the RS- printer port. Upgrades to the operating system are also made through the printer port. Remote I/O with Communications Port (8K Units only) Remote I/O versions without a printer port have a selectable RS-8 / RS- communications port. This communications port is only for the transfer of application files and upgrading the operating system. You cannot use this port to connect to a host controller. 6
7 8K or 0K Memory The DTAM Plus can be ordered with 8K or 0K memory. The 8K version stores up to approximately 0 screens. The 0K version stores up to approximately screens. Printer Port An RS-C printer port is standard on 0K memory units. This port is used to output data to a printer. Real Time Clock A real time clock is also standard on 0K memory units. The real time clock allows for time stamping of data on production reports, alarm print-outs, and operator screens. In addition, the real time clock can be synchronized with clocks in the SLC /0 or PLC- processors, or can be used create a phantom clock in the SLC /0 and /0 processors. LED Indicators The front panel of the DTAM Plus has LED indicators. Table defines the name, color and function of each LED. Table LED Indicators Indicator Color Function Run Green Lights during operation of the DTAM Plus. This indicator should always be on during DTAM Plus operation. Alarm Red Blinks when an alarm message is triggered and continues to blink until the alarm is acknowledged. Function Yellow Lights when a Function key operation is in progress. DIP Switches The DTAM Plus uses DIP switches to select various settings. The DIP switches are located under a removable plastic cover on the back of the unit. Table lists the default DIP switch settings. Table Default DIP Switch Settings DIP Switch Function Setting SW- Upload/Download Enable On SW- Communications Port Selection On SW- Master Security Enable Off SW- Function Key Enable On SW- Terminal Mode Enable Off SW-6 COMM Upload/Download Enable Off
8 Membrane Keypad The DTAM Plus uses a sealed membrane, tactile feedback keypad. Figure shows the keypad layout. Figure Keypad Layout (LCD Version) MAIN MENU PREV MENU PREV NEXT F Y N 6 EXP 8 9 CE +/ 0 The keys on the DTAM Plus keypad are color coded. Each color grouping of keys denotes a common type of operation that you can perform with these keys. Key Color Blue Dark Grey Light Grey Function Movement/Operator Response Display/Format Control Numeric Entry Function Key The Function key (F) accesses a menu of options allowing you to set features and operating parameters of the DTAM Plus. Function Key Menu C-Port (Communications Port) P-Port (Printer Port) CLK/CAL (Clock/Calendar) Reset Special 6 Term (Terminal) Test 8 Other 8 The User Manual for the provides complete details on the Function Key Menu.
9 Special Function Features The following modes are accessed using the Special option from the Function Key Menu. Mode Places the processor in either RUN mode or PROGRAM mode. Clear Fault Clears all processor faults in the PLC or SLC. Memory Transfer Enables the Memory Transfer feature. To use this function, the processor must be in PROGRAM mode, and the applicable memory module must be installed. Point/Access Display (P/AD) Allows user to display and/or modify data files in processors. The file type determines whether the data is Read Only or Read/Write. The tables below list access for each file type in SLC and PLC platforms: SLC File Types PLC File Types Default File File Type Data Access File Type Identifier Number Output Read Only Output O 0 (fixed) Input Read Only Input I (fixed) Status Read/Write Status S (fixed) Binary Read/Write Binary B Timer Read/Write Timer T Counter Read/Write Counter C Control Read/Write Control R 6 Integer Read/Write Integer N ASCII ➀ Read Floating Point F 8 ASCII String ➀ Read ASCII A 9 Floating Point ➀ Read/Write BCD D 0 Block Transfer BT ➀ Not used by SLC 00/0/0 processors Message MG PID PD SFC SC ASCII String ST Refer to the DTAM Plus User Manual, publication for additional information on the P/AD functions. 9
10 DTAM Plus to PLC/SLC Connections The following figures show the flexible connection options between either the DTAM Plus and the SLC 00 or PLC- using various cabling. Figure DTAM Plus SLC 00 Direct Connections DTAM Plus RS-8 Communications Port SLC /0, /0, /0 Programming Port Communications Cable Catalog No. 0-NC Std. DTAM Plus (no printer port) SLC /0, /0, /0 DTAM Plus and SLC are connected to same power source and ground potential Typical Address Assignments DTAM Plus Address 0 SLC XX Address Max Node Address Figure DTAM Plus SLC 00 Network Connections (Greater than Meters) DTAM Plus # DTAM Plus # Printer Communications Cable Catalog No. 0-NC DTAM Plus RS-8 Communications Port Communications Cable Catalog No. 0-NC DTAM Plus RS- Printer Port DH 8 Network Link Couplers Catalog No. -AIC DTAM Plus # SLC /0, /0 Programming Port Communications Cable Catalog No. -C Address 0 Std. DTAM Plus SLC /0 or /0 DTAM Plus and SLC are separated by distances greater than two meters (6.6 feet) DTAM Plus # Address SLC XX Address Max Node Address 0
11 Figure DTAM Plus to PLC- using RS-C/ Communication (Point-to-Point only) PLC- DTAM Plus Operator Interface DTAM Plus RS-C/8 Communications Port Channel 0 Communications Cable Use Catalog No. 0-NC for RS-C Use Catalog No. 0-NC for RS- Figure DTAM Plus Remote I/O Link Connection PLC- Computer Remote I/O Network Remote I/O DL0 RediPANEL PanelView Cabling (Catalog No. 0-CD) Belden 96
12 Figure 6 DTAM Plus Remote I/O SLC Connection SLC /0 DTAM Plus Operator Interface DTAM Plus Remote I/O Port RIO Scanner (Catalog No. -SN) Cabling (Catalog No. 0-CD) Belden 96 Figure DTAM Plus Remote I/O Direct PLC Connection PLC- DTAM Plus Operator Interface DTAM Plus Remote I/O Port Cabling (Catalog No. 0-CD) Belden 96 Figure 8 DTAM Plus to SLC /0 and /0 using RSC/ Communication DTAM Plus Operator Interface DTAM Plus RS-C/8 Communications Port SLC /0, /0 Channel 0 RS C/ Communications Cable Catalog No. -CP (needs male-to-male gender changer) Std. DTAM Plus (no printer port) SLC /0, /0
13 Cabling Diagrams The following figures show the cabling requirements for the different DTAM Plus configurations. Figure 9 shows the cabling between the DTAM Plus and the SLC 00. This cable can be purchased as Catalog No. 0-NC. Figure 9 DTAM Plus to SLC 00 RS-8 Cable Cable (Catalog No. 0-NC) DTAM Plus RS-8 Communication Port SLC 00 Programming Port or Isolated Link Coupler (Cat. No. -AIC) Peripheral Port (8 Pin, RJ Connector, AMP #-9-X) = Male Connector 6 8 DTAM Plus RS-8 = Data Out = Data Out + = Data In = Data In + 6 = Transmit Enable 8 = Ground 9 = Shield SLC 00 Port = Data (CH A) = Data (CH B) = VDC = Gnd RS-8 = Transmit Enable TX-EN 6 = Shield = Gnd RS-8 8 = VDC Figure 0 shows the cabling for the optional printer port of the DTAM Plus. Use this port to send data to a printer or serial device such as a large display. Figure 0 DTAM Plus RS-C Printer Port Cable DTAM Plus RS-C Printer Port RS-C Printer or Serial Device = Female Connector 6 = Male Connector 8 9 DTAM Plus RS-C 9 Pin = Data Out = Signal Ground = Request to Send 8 = Clear to Send RS-C 9 Pin = Data In = Signal Ground = Request to Send 8 = Clear to Send or RS-C Pin ➀ = Data In = Request to Send = Clear to Send = Signal Ground ➀ Use this pinout if printer or serial device has a pin connector.
14 Figure shows the cabling requirements for uploading/downloading data between the serial port of a computer and the RS-C communications or printer port of the DTAM Plus. This cable can be purchased as Catalog No. 0-NC. Figure DTAM Plus RS-C Communications or Printer Port Upload/Download Cable Male Connector when using comm port Female Connector when using printer port Cable (Catalog No. 0-NC) DTAM Plus RS-C ➀ Communications or Printer Port Computer 9 Pin Serial Port (COM, COM) = Female Connector Male Connector when using comm port Female Connector when using printer port DTAM Plus RS-C ➀ Communications or Printer Port Computer Pin Serial Port (COM, COM) 6 DTAM Plus RS-C 9 Pin = Data In = Data Out = Signal Ground RS-C 9 Pin = Data In = Data Out = Signal Ground ➀ The communications port of the DTAM Plus must be set to RS. ➁ Use this pinout if computer has a pin connector. DTAM Plus RS-C 9 Pin = Data In = Data Out = Signal Ground = Female Connector RS-C Pin ➁ = Data Out = Data In = Signal Ground Figure shows the cabling requirements between a PLC- and the DTAM Plus when channel 0 of the PLC- is configured for RS-. This cable can be purchased as Catalog No. 0-NC. Figure DTAM Plus to PLC- RS-C DF Communications Cable Cable (Catalog No. 0-NC) DTAM Plus RS-C ➀ Communications Port PLC- Channel = Male Connector DTAM Plus RS-C 9 Pin = Data In = Data Out = Signal Ground PLC- Channel 0 = Data Out = Data In = Signal Ground = RTS = CTS 6 = DSR 8 = DCD 0 = DTR ➀ The communications port of the DTAM Plus must be set to RS-.
15 Figure shows the cabling requirements between a PLC- and the DTAM Plus when channel 0 of the PLC- is configured for RS-. This cable can be purchased as Catalog No. 0-NC. Figure DTAM Plus to PLC- RS- DF Communications Cable Cable (Catalog No. 0-NC) DTAM Plus RS- ➀ Communication Port PLC- Channel = Male Connector 9 RS-8 = Data Out = Data Out + = Data In = Data In + = Signal Ground RS- = Data Out = Data Out + = Data In 6 = Data In + = Signal Ground 6 = DSR 8 = DCD 0 = DTR = RTS + = CTS + = CTS 9 = RTS ➀The communications port of the DTAM Plus must be set to RS-8. Figure shows the cable required to connect an ASCII device to the DTAM Plus printer port. Use this cable with Allen-Bradley decoded bar code scanners (Catalog No. -G-D, -G6-D). Figure ASCII Input Cable DTAM Plus RS-C Printer Port Cable (Catalog No. 0-NC6) ➀ Bar Code Scanner Pin Serial Cable 6 DTAM Plus RS-C 9 Pin = Data In = Data Out = Signal Ground = Female Connector = Male Connector RS-C Pin = Data Out = Data In = Signal Ground ➀The communications port of the DTAM Plus must be set to RS-.
16 Cutout Template Below is the panel cutout template for the DTAM Plus..98 inch = 00.0 mm. inch = 96. mm.6 inch =.8 mm.86 inch = 9. mm.88 inch =.8 mm 0. inch =. mm 0.08 inch =.98 mm.98 in. in DTAM PLUS Panel Cutout Template.6 Inch x. Inch.8 mm x 96. mm.88 in dia 6 places.98 in 0.08 in 6 0. in.6 in.86 in
17 DTAM Plus Specifications Display Column and Character Display Technology LCD (0-L versions) VFD (0-V versions) lines x 0 characters Twisted-nematic type with adjustable LED (yellow) backlighting Vacuum Fluorescent Display with viewing distance that exceeds feet (.6 meters) Backlight Settings for LCD Version (via Keypad) Four (0,,66 and 00%) Contrast Ratio 0: Contrast/Brightness Settings (Keypad) LCD (0-L versions) settings VFD (0-V versions) settings Display Size (H x W) LCD (0-L versions).0 x.0 in (. x 6.0 mm) VFD (0-V versions). x.9 in (.0 x 99.0 mm) Character Size (H x W) 0.9 x 0. in (. x.9 mm) Keypad Keypad Type Tactile Feedback Operation Force Operational Life Embossed, sealed membrane Stainless steel dome oz. ± oz. (0 grams ± 8 grams) million cycles Electrical Communications Port Printer Port (0K memory units) Serial Communication Distances RS-8 RS-C RS- RS-8 or RS-C (configurable) RS-C,000 ft (9 meters) maximum with the Link Coupler (Catalog No. -AIC) 0 ft ( meters) maximum 00 ft (6 meters) maximum to a PLC- Remote I/O Communication Distances.6K 0,000 ft (000 meters) maximum.k,000 ft (00 meters) maximum 0.K,00 ft (0 meters) maximum Voltage, Current, Fusing Requirements Power Supply Voltage Current Fuse P - V AC, - 0 Hz or 0-0V DC 00 ma max. amp P 8-6V AC, - 0 Hz or 0-0V DC 0 ma max. / amp Port Isolation Communication Port Printer Port 00V isolation 00V isolation
18 Environmental Ambient Temperature Rating Operating LCD Display 0 to + C ( to F) VFD Display 0 to +60 C ( to 0 F) Storage -0 to +8 C (- to 8 F) Relative Humidity Agency Rating Mechanical Dimensions (Approximate) Height Width Depth RS- / RS 8 Versions Remote I/O Versions Front Panel Size Height Width Weight All except 0-V0PN 0-V0PN LED Indicators RUN LED Alarm LED Function LED to 9%, noncondensing NEMA Type,, (indoor use only) NEMA Type X (0-V0PN version only) UL Listed (File #E09) Factory Mutual Class Division listed Groups A, B, C, D Hazardous Locations UL tested to meet CSA requirements.6 inch (9.0 mm). inch (9. mm).8 inch (. mm).0 inch (0.8 mm) 8. inch (.9 mm) 6. inch (6. mm). lbs (0.9 kg).6 lbs (.09 kg) Green Red Yellow 8
19 A B 9
20 PLC is a registered trademarks of Allen-Bradley Company, Inc. SLC and SLC 00 are trademarks of Allen-Bradley Company, Inc. IBM is a registered trademark of International Business Machines Corporation PC AT, PS/ and PC XT are trademarks of International Business Machines Corporation Publication 0-.0 October 99 Supersedes Publication 0-.0 Dated January 99 Copyright 99 Allen-Bradley Company, Inc. Printed in USA
7-1. Section Seven Operator Interface. (Continued) Operator Interface Overview
Section Seven Operator Interface Operator Interface Overview...................................... 7-3 Message Displays MessageView Interactive Message Display Terminals.................. 7-6 Dataliner
More informationA B A B. (Catalog Number 2707-MVH232, -MVP232) Product Data
A B A B (Catalog Number 2707-MVH22, -MVP22) Product Data 9 9 The MicroView Operator Interface extends the Bulletin 2707 product line, providing an interface with the Allen-Bradley MicroLogix family of
More informationRemote I/O Scanner. Catalog Number 1747-SN. Installation Instructions. Publication
Remote I/O Scanner Catalog Number 1747-SN Installation Instructions 2 Remote I/O Scanner Important User Information Because of the variety of uses for the products described in this publication, those
More information1.6. Counters, Panel Meters, Tachometers and Timers. Contents Description Fusion Integrated Machine Control Standards and Certifications...
.6 Contents Standards and Certifications............... Product Selection....................... Technical Data and Specifications........... Dimensions............................ Learn Online Page V3-T-04
More informationWindows-compatible BASIC Module Interface Software (1747-WINBAS) BASIC Language Modules Catalog Numbers and Specifications
Select SLC 500 I/O s 37 BASIC Language s s and Specifications Attribute 1746-BAS 1746-BAS-T Maximum communication distance RS-232 (300 19200 bps) RS-423 (300 bps) RS-423 (600 bps) RS-423 (1200 bps) RS-423
More informationRemote I/O Scanner. Installation Instructions. (Catalog Number 1747-SN)
Installation Instructions Remote I/O Scanner (Catalog Number 1747-SN) Inside...page Hazardous Location Considerations... 2 Environnements dangereux... 2 Overview... 3 Hardware Features... 4 Required Tools
More informationQuick Start Installation Guide
apc/l Quick Start Installation Guide Version A2 Document Part Number UM-201 May 2010 OVERVIEW The apc/l is an intelligent access control and alarm monitoring control panel which serves as a basic building
More informationMicroView Operator Interface Module
MicroView Operator Interface Module Catalog No. 2707-MVH232, 2707-MVP232 User Manual Important User Information Because of the variety of uses for the products described in this publication, those responsible
More informationAllen-Bradley. Dataliner DL5 Slave Displays (Cat. No D11JS, -D21JS) User Manual
Allen-Bradley Dataliner DL5 Slave Displays (Cat. No. 2706-D11JS, -D21JS) User Manual Important User Information Because of the variety of uses for the products described in this publication, those responsible
More informationPROGRAMMABLE MESSAGE DISPLAYS
PROGRAMMABLE MESSAGE DISPLAYS AVG UTICOR Programmable Message Displays (PMDs), are found in numerous applications throughout all industries. PMDs are extremely versatile products, enabling your PLC or
More informationPanelView Standard Operator Terminals
PanelView Standard Operator Terminals PV300 Micro, PV300, PV550, PV600, PV900, PV1000, PV1400 User Manual Important User Information Because of the variety of uses for the products described in this publication,
More informationInstalling the Panel. Installing the Panel
7 In this section you will be given all of the information you need to install the panel. Before actually installing the OP- panel, it may be helpful to examine the specifications and make sure that the
More informationTABLE OF CONTENTS. Communication Functions
TABLE OF CONTENTS Chapter 1: Chapter 2: Chapter 3: Chapter 4: General Features....................................................... 1-1 Functions......................................................
More informationAdvantages for the MicroLogix 1500 Controller (in addition to MicroLogix 1200 controller features)
MicroLogix Programmable Controllers Overview 13 Advantages for the MicroLogix 1500 Controller (in addition to MicroLogix 1200 controller features) Large memory to solve a variety of applications. 1764-LSP:
More informationOperator Interfaces Introduction & Selection Guide SELECTION GUIDE INTRODUCTION UCT-31P
Introduction & Selection Guide UCT-30 UCT-31 UCT-31P UCT-34 UCT-34P UCT-36 INTRODUCTION Brodersen message displays and operator panels provide the operator with relevant information about e.g. operating
More informationMessage Display Operator Panel. UCT-33/36 Industrial Terminal. Manual 32.00
BRODERSEN Message Displays/Operator Panels Message Display Operator Panel UCT-33/36 Industrial Terminal Manual 32.00 Brodersen Controls A/S. Betonvej 0. DK-4000 Roskilde. Denmark. Tel (+45) 46 74 00 00.
More informationModels: TD3000 Series. Table Displays. 2 by 20 character display USER MANUAL
Models: TD3000 Series Table Displays 2 by 20 character display USER MANUAL i NOTICE The manufacturer of the POS table display makes no representations or warranties, either expressed or implied, by or
More informationSmartMod DC Digital Input Module HE359DIM610 12/24VDC Negative Logic
MAN0842-02 DIM610 PAGE 1 of 6 SmartMod DC Digital Input Module HE359DIM610 12/24VDC Negative Logic 1 SPECIFICATIONS Number of Channels Input Ranges DIM610 12 PLC Update Rate 12/24 VDC Terminal Type DIM610
More informationInstallation and Programming Manual. Niobrara Research & Development Corporation P.O. Box 3418 Joplin, MO USA
DUCM DF1 Manual DUCM DF1 Installation and Programming Manual This manual describes the DUCM application for interfacing DF1 slaves to a Modbus or RNIM serial network. Effective: February 16, 2017 Niobrara
More informationDataliner DL40 Plus Message Displays
Release Note Dataliner DL40 Plus Message Displays The Dataliner DL40 Plus Message Displays, the next generation of Allen-Bradley message displays, directly replace the Dataliner DL40, DL20 and DL10 Series
More informationArtisan Technology Group is your source for quality new and certified-used/pre-owned equipment
Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment FAST SHIPPING AND DELIVERY TENS OF THOUSANDS OF IN-STOCK ITEMS EQUIPMENT DEMOS HUNDREDS OF MANUFACTURERS SUPPORTED
More informationSelect Family: MicroLogix 1100 or 1400 Controller
Select Family: MicroLogix 1100 or 1400 Controller 21 Select Family: MicroLogix 1100 or 1400 Controller Step 1 - Select: controller family - based on memory, I/O, added functionality, programming instructions
More informationMicroLogix 1000 Programmable Controllers
Technical Data MicroLogix 1000 Programmable Controllers Bulletin 1761 2 MicroLogix 1000 Programmable Controllers Table of Contents MicroLogix 1000 System............................................. 3
More informationDo Not Copy. Important User Information For More Information... 3
Installation Instructions DH/RS-C Interface Module (Catalog Number 1-KE) Inside page Important User Information... For More Information... Hazardous Location Considerations... Environnements dangereux...
More informationPROGRAMMABLE MARQUEE DISPLAYS
PROGRAMMABLE MARQUEE DISPLAYS INTRODUCTION: AVG Uticor Marquees can be found in numerous applications throughout all industries. In 1996, a CONTROL ENGINEERING Magazine study named the AVG Uticor brand
More informationSimplified information where and how you want it.
ConsolIdator 4 & 8 Multi-channel controllers Simplified information where and how you want it. ConsoliDator 4 Model PD940 ConsoliDator ConsoliDator 4 Features Four 4-20 Inputs Four 4-20 Outputs ConsoliDator
More informationUSER S MANUAL. PH232Ex1. #1 RS-232 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH232Ex1-UM-001 IPEX. (IP Electronix)
USER S MANUAL PH232Ex1 Doc No: PH232Ex1-UM-001 #1 RS-232 Serial Port to Ethernet, Terminal Server/Client IPEX (IP Electronix) Contents 1. INTRODUCTION... 3 2. SPECIFICATIONS... 3 3. PACKAGE CHECKLIST...
More informationPanelView Plus/VersaView CE Terminals and Display Modules
Installation Instructions PanelView Plus/VersaView CE Terminals and Display Modules (Catalog Numbers 2711P-xxxxxx, 6182H-xxxxxx) English Inside: Overview...2 For More Information...2 Modular Components...3
More informationModels: LD9000 Series. Customer Displays. 2 by 20 character display USER MANUAL
Models: LD9000 Series Customer Displays 2 by 20 character display USER MANUAL i NOTICE The manufacturer of the POS pole display makes no representations or warranties, either expressed or implied, by or
More informationThe ECL Apex 20 is operated by means of either a PC or the ECL Apex Web Panel. Temperature input signals are based on Pt 1000 or 0-10 V.
ECL Apex 20 controller and ECA 20 (ECL Apex Web Panel) Description ECL Apex 20 and ECA 20 ECL Apex 20 The ECL Apex 20 and the ECA 20 (ECL Apex Web Panel) are used in large district heating applications.
More informationWeight ounces Panel Fasteners... Four holes to accept four 16x32 machine screws NEMA Rating... NEMA 1
8 Panel Specifications: In this section, you will be given all of the information you need to install the panel. Before actually installing the OP-9001 panel, it may be helpful to examine the specifications
More informationModel: KB1700. Programmable Keypad. 17 Programmable Keys USER MANUAL
Model: KB1700 Programmable Keypad 17 Programmable Keys USER MANUAL NOTICE The manufacturer of the POS programmable keypad makes no representations or warranties, either expressed or implied, by or with
More informationT1K MODBUS Base Controller Specifications
Base Controller 1 2 In This Chapter.... Base Controller Setting the DIP Switches Setting the Rotary Address Switches Port Pin out and Wiring RJ12 Serial Port Pin out and Wiring 2 2 Base Controller General
More informationData communication and reporting unit
SRIO 500M Data communication and reporting unit User s manual and Technical description SRIO 500M FAULT ON 1 2 SERIAL IF 4 LOCAL 1 2 3 4 5 6 7 8 1 0 0542A 1MRS 750540-MUM EN Issued 1996-10-23 Modified
More informationNote: the wiring of the dead-man buttons has been changed since October 2001.
UniOP epalm10 The epalm10 is a state-of-the-art handheld HMI device with a graphic display and a keypad. The rugged polyamide enclosure offers a high level of shock and environmental resistance making
More informationUser Manual. Allen-Bradley. PanelView 1000e, 1200e, and 1400e Operator Terminals
Allen-Bradley PanelView 1000e, 1200e, and 1400e Operator Terminals User Manual (Cat. No. 2711E-T10C6, 2711E-K10C6, 2711E-T10C7, 2711E-K10C7, 2711E-T10C15, 2711E-K10C15, 2711E-K12C6, 2711E-K12C6L2, 2711E-T12C6,
More informationIn this chapter... Manual Organization Introduction to the EZText Panel What you need to get started Need HELP? Models PLCs Supported by EZText Panel
Introduction 1 In this chapter... Manual Organization Introduction to the EZText Panel What you need to get started Need HELP? Models PLCs Supported by EZText Panel Accessories and Optional Equipment PLC
More informationModel: LK7000. Programmable Matrix Keyboard. 119 Keys with Built-in Scanner and MSR USER MANUAL
Model: LK7000 Programmable Matrix Keyboard 119 Keys with Built-in Scanner and MSR USER MANUAL NOTICE The manufacturer of the POS programmable keyboard makes no representations or warranties, either expressed
More informationDL2000. User s Guide
DL000 User s Guide Revision.0 April, 00 Equustek Solutions, Inc. Suite 8, 00 W7rd Ave. Vancouver, BC, Canada V6P 6G Toll Free: 888-87-787 http://www.equustek.com Table of Contents.0 DL000 General Operation
More informationConnect to the Future Today with Allen-Bradley s SLC 5/05 Processor with Ethernet
Connect to the Future Today with Allen-Bradley s SLC 5/05 Processor with Ethernet SLC 5/05 Programmable Controllers (Cat. Nos. 1747-L551, -L552, -L553) Product Profile Allen-Bradley s SLC 5/05 Programmable
More informationNote: For BANDIT II, BANDIT III, or VSR-1200 specifications, see the BANDIT II, BANDIT III, and VSR-1200 Document Set. Function
Appendix A Specifications This appendix lists the specifications for the BANDIT family of products. Note: For BANDIT II, BANDIT III, or VSR-1200 specifications, see the BANDIT II, BANDIT III, and VSR-1200
More informationData communication and reporting unit
FAULT SRIO 1000M Data communication and reporting unit User s manual and Technical description SRIO 1000M ON 1 2 SERIAL IF 4 LOCAL 1 2 3 4 5 6 7 8 1 0 0543A 1MRS 750533-MUM EN Issued 1996-10-23 Modified
More informationVorne Industries. 2000S Series Serial Input Alphanumeric Display User's Manual
Vorne Industries 2000S Series Serial Input Alphanumeric Display User's Manual 1445 Industrial Drive Itasca, IL 60143-1849 Telephone (630) 875-3600 Telefax (630) 875-3609 2000S Series Serial Input Alphanumeric
More information24 Input/8 Output AC Block I/O Module
4 Input/8 Output AC Module Cat. No. 79-4A8 Series B Installation Mount the block I/O module in a vertical (recommended) or horizontal position. Allow sufficient room around the block for cooling air to
More informationC-more Micro-Graphic Panel Accessories
8-Button Keypad Bezel The 8-button keypad bezel can be used with both the touch and non-touch Micro-Graphic panels. The keypad includes four directional arrow cursor buttons, and one each of an ESCAPE,
More informationThis Datasheet for the 2711P-T15C4D8. PanelView Plus in. Color Touchscreen Terminal. Standard
This Datasheet for the 2711P-T15C4D8 PanelView Plus 6 1500 15in Color Touchscreen Terminal Standard Communications (Ethernet & RS232) DC Input Power Memory 512 RAM / 512 Nonvolatile http://wwwqualitrolcom/shop/p-16474-2711p-t15c4d8asp
More informationSystem Overview. PanelView Standard Operator Interface Terminals
System Overview PanelView Standard Operator Interface Terminals PanelView Standard Get The View Experience Complete Satisfaction With Allen-Bradley Since 1903, Rockwell Automation s Allen-Bradley has earned
More informationContinuous level measurement Ultrasonic controllers
Siemens AG 0 Overview is a complete ultrasonic level controller for monitoring and control of water distribution and wastewater collection systems, with energy-saving algorithms. Benefits Monitoring and
More informationLevel instruments. Continuous level measurement - Ultrasonic controllers SITRANS LUC500. 5/146 Siemens FI
SITRANS LUC00 Siemens AG 009 Overview SITRANS LUC00 is a complete ultrasonic level controller for monitoring and control of water distribution and wastewater collection systems, with energy-saving algorithms.
More informationProduct Description. Contents. Fusion Series. New Information December 2003
Fusion Series Technical Data New Information December 2003 Durant Fusion Product Description The Durant Fusion from Eaton Electrical is an industrial control unit consisting of a high speed count control
More informationMRUC-20 Modul-R CAN Bus Network
MRUC-20 Modul-R CAN Bus Network BALOGH This manual is based on information available at the time if its publication. Every effort has been made to provide accurate and up-to-date information. This document
More information4 INSTALLATION. Installing the EZTouch Panel requires the following three major steps:
Installing the EZTouch Panel requires the following three major steps: Mounting Connections and Wiring Communications Setup The EZTouch Panel is a front-panel mount unit. Mounting of the unit requires
More informationMiniature Asynchronous 4-Wire High Speed Modems
ME1862A-F ME1863A-F JULY 2003 ME1862A-M ME1863A-M Miniature Asynchronous 4-Wire High Speed Modems CUSTOMER SUPPORT INFORMATION Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500)
More informationAdvant OCS. The Compact and Cost Effective Advant Controller. Advant Controller 210. Open Control System
Advant OCS Open Control System Advant Controller 210 The Compact and Cost Effective Advant Controller Advant Controller 210 is a small, cost-effective system belonging to the Advant Controller family.
More informationInstalling Your 1394 Drive Interface Module
Installation Instructions Installing Your Drive Interface Module (Catalog Number -DIM) Introduction This publication provides installation instructions for adding the Drive Interface Module to your system.
More informationIntelligent Devices IDI 1100 Series Technical Manual
Intelligent Devices IDI 1100 Series 4411 Suwanee Dam Road, Suite 510 Suwanee, GA 30024 T: (770) 831-3370 support@intelligentdevicesinc.com Copyright 2011, Intelligent Devices, Inc. All Rights Reserved
More informationCat. No. Cat. No. Keypad Cat. No. PanelView 550 Monochrome Terminals Keypad & Touch Touch 2
Cat. No. Cat. No. Keypad Cat. No. PanelView 550 Monochrome Terminals Keypad 2 3 4 & Touch 2 3 4 Touch 2 DH-485 Communication Ports 1........................................2711-K5A2..........2711-B5A2..........2711-T5A2L1
More informationFlexibility: The GW1000 allow multiple Ethernet/IP and AB Ethernet Application to message Multiple DH+ Nodes.
GW1000-ABEIP Datalink Ethernet IP to DH+ Datalink AB Ethernet to DH+ The DataLink GW1000-ABEIP is a gateway between both Ethernet/IP and AB Ethernet to AB s DH+ Network. The GW1000 interfaces any newer
More informationF1000 User's Manual. (Version: V1.01)
(Version: V1.01) Contents Chapter 1 Overview... 2 Chapter 2 Installation... 3 2.1 Installation guide... 3 2.1.1 Installation position... 3 2.1.2 NEMA4 standard installation... 3 2.1.3 Environment precautions...
More informationPrisma II Platform. Optoelectronics
Optoelectronics Prisma II Platform Description In optical transmission systems, the network platform forms the foundation of the product family. The Prisma II platform provides network operators with the
More informationWiring Section 3-3. NQ-Series communication ports support various types of (serial) communication.
3-3 Wiring NQ-Series models have, besides one power connector, a number of communication ports. Please refer to Table 2.2: Common specifications for NQ-Series and Table 2.3: Specifications per NQ-Series
More informationEQ-DCM User Manual Revision 1.02 Sep 10, 2013
EQ-DCM User Manual www.equustek.com Revision 1.02 Sep 10, 2013 Contents INTRODUCTION...5 ABOUT THIS MANUAL... 5 INTENDED AUDIENCE... 5 HARDWARE SPECIFICATIONS...6 PHYSICAL SPECIFICATIONS... 6 HARDWARE
More informationAbsolute Encoders Multiturn
The multiturn encoders 6 and 8, with interface and combined optical and magnetic sensor technology, offer a maximum resolution of 5 bits. These encoders are programmable via the Ezturn software. The hollow
More informationDPS INC ASCII MUX. Operation Guide. Table Of Contents. Overview. T/kda
DPS INC Operation Guide "Your Partners in Telemetry Monitoring Systems" ASCII MUX Fig. - ASCII MUX Expands T/MonXM ASCII s up to Eight Times Table Of Contents Overview... Functional Schematic... Typical
More informationP3000 PowerMarquee Master Display Hardware User Manual. (Manual Part Number MAN-P )
P3000 PowerMarquee Master Display Hardware User Manual (Manual Part Number ) WARNING! Programmable control devices such as UTICOR s P3000 PowerMarquee Master, must not be used as stand-alone protection
More informationSCADAPack Vision. Operator interface terminal. Vision10 Vision60
SCADAPack Vision Operator interface terminal 1 The SCADAPack Vision is a compact, panel-mounted operator interface terminal for use with SCADAPack controllers or other Modbus PLCs. The compact Vision10
More informationInstallation and Programming Manual
QUCM DF1 Application Manual QUCM DF1 Installation and Programming Manual This Manual describes the QUCM application for interfacing Allen-Bradley DF1 devices to a master of another protocol, including
More informationC-more 3 Micro-Graphic STN Touch Panel
R 3 Micro-Graphic STN Touch Panel This Touch Screen version of the Micro-Graphic panel has a 3.1-inch STN LCD monochrome display. Model EA1-S3ML has five selectable LED-driven backlight colors: Green,
More informationMicroView Programming Software
MicroView Programming Software Catalog No. 2707-NP2 Programming Manual Important User Information Because of the variety of uses for the products described in this publication, those responsible for the
More informationNPort Z2150/Z3150 Series
NPort Z2150/Z3150 Series 1-port RS-232/422/485 to ZigBee converter or ZigBee-to-Ethernet gateway IEEE 802.15.4/ZigBee compliant Network topologies: Mesh/Star/Cluster tree 128-bit AES hardware encryption
More informationNPort IA5000A Series. 1, 2, and 4-port serial device servers for industrial automation. Overview
Serial-to-Ethernet Device Servers NPort IA5000A Series 1, 2, and 4-port serial device servers for industrial automation Enhanced surge protection for LAN/serial/power 2 kv isolation for serial signals
More informationPCL Port RS-232 Interface Card
PCL-858 8-Port RS-232 Interface Card Copyright Notice This documentation and the software included with this product are copyrighted 2001 by Advantech Co., Ltd. All rights are reserved. Advantech Co.,
More informationE Serial Controller
SmartSet Technical Reference Manual Addendum for the E281-2310 Controller 1 E281-2310 Serial Controller The following figure shows the mounting dimensions, jumper locations, and connections for the IntelliTouch
More informationBeagleBone Black USB Expansion RS232 Module Cape Coolgear, Inc. Version 1.1 September 2017 Model Number:
BeagleBone Black USB Expansion RS232 Module Cape Product Manual Coolgear, Inc. Version 1.1 September 2017 Model Number: USB-2COM-BB 2 USB-2COM-BB Product Manual Revision History Revision Date Author Comments
More informationGetting Started. In This Chapter... Introduction OP-1500/OP-1510 Overview Frequently Asked Questions
In This Chapter.... Introduction OP-1500/OP-1510 Overview Frequently Asked Questions 1 2 Introduction The Purpose of this Manual Contents of the Manual This User Manual provides user information on panel
More informationMODCELL 2050R Single Loop Controllers
Isolated universal process and remote set-point input Four internal set-points No jumpers required to define instrument parameters Ratio/bias on process and remote set-point Totalizer Ramp/soak profile
More informationAdvantages for the MicroLogix 1400 Controller
10 MicroLogix Programmable Controllers Overview dvantages for the MicroLogix 1400 Controller Large memory (10 K user program with 10 K user data) to solve a variety of applications. True online editing
More informationMGate 5111 Quick Installation Guide
MGate 5111 Quick Installation Guide Edition 1.0, December 2017 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777 Fax: 1-714-528-6778
More informationEP/2 Installation Instructions
1 2 3 4 7 ENTER 0 5 6 8 9 CLEAR + - LOGIC ONE EP/2 EP/2 Installation Instructions DOC. #569011000 A 7/30/04 PRINTED IN U.S.A. Regulatory Compliance Safety This device has been tested and found to be in
More informationFeatures and Benefits. Certifications
NPort IA5000 Series 1 and 2-port serial device servers for industrial automation Features and Benefits Socket modes: TCP server, TCP client, UDP Patented ADDC (Automatic Data Direction Control) for 2-wire
More informationMagnetically Actuated Safety Interlock Switches
Conforms to EN10, EN292, EN020-1 CSA and BG approved Actual Size Magnetically Actuated Safety Interlock Switches Large selection choose from a large selection of contact configurations housed in plastic,
More informationEtherSeries. EtherSeries CR-2. CR-2-Opto. User s Guide. Revised October 7, 2013 Firmware Version 1.X
EtherSeries EtherSeries CR-2 & CR-2-Opto User s Guide Revised October 7, 2013 Firmware Version 1.X TABLE OF CONTENTS SECTION 1 - DESCRIPTION... 2 SECTION 2 - SPECIFICATIONS... 4 SECTION 3 - INSTALLATION...
More informationSLC 500 BASIC and BASIC-T Modules
SLC 500 BASIC and BASIC-T Modules (Catalog Numbers 1746-BAS and 1746-BAS-T) User Manual Important User Information Because of the variety of uses for the products described in this publication, those responsible
More informationMICRO SERIES PROCESS DISPLAYS LARGE DIGIT MODELS
The MICRO SERIES PROCESS DISPLAYS LARGE DIGIT MODELS Mighty-5 DPM MODELS Micro-P & Mighty-1 Mighty-1 Micro-P ELECTRO-NUMERICS, INC. Introduction The Electro-Numerics family of Digital Panel Meters and
More informationPACSystems* RX3i IC695CMM002 and IC695CMM004
May 2010 PACSystems* RX3i IC695CMM002 and IC695CMM004 Serial Communications Modules PACSystems* RX3i Serial Communications modules expand the serial communications capabilities of the RX3i system. Serial
More informationPLC Driver Manual 2800 & 2900
PLC Driver Manual 2800 & 2900 Compact Operator Interface Terminals with PLC communication drivers Quartech Corporation 15943 Angelo Drive Macomb Township, Michigan 48042-4050 Phone: (810) 781-0373 FAX:
More informationPico Accessories. Memory Modules. This section provides information on various accessories.
Pico and Pico GFX-70 Programmable Controllers 15 Table 3 Pico Expansion I/O Module Selection Cat. No. Input Voltage Category Number of Inputs Number of Outputs (Digital) 1760-IA12XOW6I 120 / 240V ac 12
More informationE510. Compact Drive IP 20/ NEMA HP (230V) 1-75 HP (460V)
E510 Compact Drive IP 20/ NEMA 1 0.5-40 HP (230V) 1-75 HP (460V) Control Mode Application & Selection Guide The E510 compact AC Drive is an easily configurable product that controls many motor driven applications.
More informationCisco Prisma II Platform
Cisco Prisma II Platform In optical transmission systems, the network platform forms the foundation of the product family. The Cisco Prisma II platform provides network operators with the unique features
More informationManual Swipe Magnetic Card Reader
R Manual Swipe Magnetic Card Reader Peripheral-type, Compact, Manually Operated Card Reader H Connects to the PC RS-232C port just like any other peripheral H Sits conveniently next to the PC keyboard
More informationAllen-Bradley. User Manual. PLC-5 Backup Communication Module (1785-BCM, 1785-BEM) product icon
Allen-Bradley PLC-5 Backup Communication Module User Manual (1785-BCM, 1785-BEM) product icon Important User Information Because of the variety of uses for this product and because of the differences between
More informationMODEL: R1M-P4. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)
PC Recorders Series PC RECORDER (4 totalized counter inputs, 8 contact inputs and outputs) Functions & Features Industrial recorder on PC Totalized counter inputs Counts stored in E 2 PROM Easy system
More informationDT Desktop Series
5600-8-DT Desktop Series Compact 8-port Serial s Features 8 ports supporting RS-232, RS-422, or RS-485 operation Compact desktop size Auto-detecting 10/ 100 Mbps Ethernet 15 KV ESD surge protection for
More informationAIC+ Advanced Interface Converter. Catalog Number 1761-NET-AIC. User Manual. Allen-Bradley Spares
AIC+ Advanced Interface Converter Catalog Number 1761-NET-AIC User Manual Allen-Bradley Spares Important User Information Solid state equipment has operational characteristics differing from those of electromechanical
More informationRTU560 Connections and Settings DIN Rail RTU 560CIG10
Connections and Settings DIN Rail RTU 560CIG10 Application, characteristics and technical data have to be taken from the hardware data sheet: 560CIG10 1KGT 150 719 Operation The 560CIG10 is a DIN rail
More informationRemote I/O Adapter Module
Installation Instructions Remote I/O Adapter Module (Catalog Number 1747-ASB) Inside...page Hazardous Location Considerations...2 Environnements dangereux...2 1747-ASB Module Overview...3 Required Tools
More informationFeatures and Benefits. Certifications
MPC-2240 Series 24-inch ECDIS color calibrated, fanless panel computers Features and Benefits 24-inch panel computer Color calibrated for ECDIS compliance Intel Core processor: i7 3517UE 1.7 GHz or Celeron
More informationPMD 180 Master Message Displays
PRD. CATEGORY : PROGRAMMABLE MESSAGE DISPLAYS The PMD 180 is a compact and versatile 2- or 4-line programmable message display with 20 or 40 vacuum fluorescent characters per line 0.197" (5 mm) high. The
More informationGW1000 User s Guide. Revision 1.04 Mar 30, 2008
GW1000 User s Guide Revision 1.04 Mar 30, 2008 Website: www.datalink-networks.com Tel : (604) 632-4278 / (866) 709-6390 Table of Contents 1.0 GW1000 General Operation & Applications... 3 2.0 Hardware Specifications...
More informationAD-8923-BCD. Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD
AD-8923-BCD Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD4002137 2010 A&D Company, Limited. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, or translated
More information