Modular I/O Solutions Designed for Open Network Systems

Size: px
Start display at page:

Download "Modular I/O Solutions Designed for Open Network Systems"

Transcription

1 M-SYSTEM WARRANTY. What is covered. M-System Co., Ltd. ( M-System ) warrants, only to the original purchaser of new M-System products purchased directly from M- System, or from M-System s authorized distributors or resellers, for its own use not for resale, that the M-System products shall be free from defects in materials and workmanship and shall conform to the specifications set forth in the product catalogue applicable to the M-System products for the Warranty Period (see Paragraph below for the Warranty Period of each product). THE ABOVE WARRANTY IS THE ONLY WARRANTY APPLICABLE TO THE M-SYSTEM PRODUCTS AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIM- ITED TO, ALL IMPLIED WARRANTIES OF MERANTABILITY OR OF FITNESS FOR A PARTICULAR PURPOSE.. What is not covered. This warranty does not cover any M-System product which has been: () modified, altered or subjected to abuse, misuse, negligence or accident; () improperly installed or installed in conjunction with any equipment for which it was not designed; or () damaged or destroyed by disasters such as fire, flood, lightning or earthquake. In no event shall M-System be liable for any special, incidental, consequential or other damages, costs or expenses (including, but not limited to, loss of time, loss of profits, inconvenience or loss of use of any equipment). External Dimensions mm (inch) Exact dimensions differ from each type. Refer to the data sheets for detail. R Series 0 (.9) 0 (.) 0 (.09) (.) M TERMINALS T T T T T T T (.) 7 (.89) (.0) (.) FOR WALL MOUNT. 8 (.) (.0) dia. MTG HOLES CJC SENSOR (model: CJM) 0 (.7). (.9) [ (.)] mm wide Modular Solutions Designed for Open Network Systems REMOTE Supports DCS/ systems by expanding their flexibility and capabilities. Stand-alone distributed communicating with popular HMI software Broad offering; DC mv, V & ma, temperature, discrete signals and other sensor inputs are supported. Four product series are available to suit various applications. REMOTE. Remedies. If a defective product is returned to M-System in accordance with the procedures described below, M-System will, at its sole option and expense, either: () repair the defective product; () replace the defective product; or () refund the purchase price for the defective product paid by the purchaser. Except as otherwise provided by applicable state law, these remedies constitute the purchaser s sole and exclusive remedies and M-System s sole and exclusive obligation under this warranty.. Warranty Procedure. If the purchaser discovers a failure of the M-System products to conform to the terms of this warranty within the Warranty Period, the purchaser must promptly (and, in any event not more than 0 days after the discovery of such failure) notify the relevant party as described below either by telephone or in writing at the below address to obtain an Authorized Return (AR) number and return the defective product to the relevant party. The designated AR number should be marked on the outside of the return package and on all correspondence related to the defective product. The purchaser shall return, at purchaser s expense, defective products only upon receiving an AR number. In order to avoid processing delays, the purchaser must include: copies of the original purchase order and sales invoice; the purchaser s name, address and phone number; the model and serial numbers of the returned product; and a detailed description of the alleged defect.. Warranty Period. Signal Conditioner: months from the date of purchase. M-Rester: months from the date of purchase. Valve Actuator: 8 months from the date of shipment from M-System or months from the date of its installation, whichever comes first. Other Products: months from the date of purchase. 0 (.) (.0). (.). (.) 90 (.) (.) A (.) A 0 (.8) 0 (.7) 0 (.79). (.0).7 (.) [ (.0)] mm wide. (.9) MODEL R-BS0 R-BS0 R-BS0 R-BS08 R-BS0 R-BS R-BS R-BS 90 (.). (.) (.9) A (.0 ) (. ) 8 (. ) ( 8.8 ) 80 (.0) (.) 9 (.) 8 (7.) [ (.0)]. (.9) mm wide M-SYSTEM CO., LTD. --, Minamitsumori, Nishinari-ku, Osaka 7-00 JAPAN Phone: (0) 9-80 Fax: (0) info@m-system.co.jp subject to change without notice. R7 Series BASE MODULE, INPUT (.) MODEL A 7 (.) R-BS0, 0 R-BS08, 09 R-BS 7 (.8 ) ( 9.09 ) 79 (.9 ) (.) 8 (.7) mm wide --, Minamitsumori, Nishinari-ku, Osaka 7-00 JAPAN Tel: +8()9-80 Fax: +8()9-80 URL: info@m-system.co.jp 0 (.97) 7 7 M TERMINALS for NETWORK, POWER (.). (.) 8 M TERMINALS. (.9) Your local representative is : EXTENSION MODULE. (.) 9 (.70) 7 (.) (.) 8 (.7) mm wide 0 (.97) (.9) Visit us at and are registered trademarks M-System Co., Ltd., registered in Japan, the United States, and other countries.. (.) 8 M TERMINALS EC-Z Rev. August 00

2 Hot Swappable, Fully Isolated Remote M-System s Remote is designed to support DCS/ systems by expanding their flexibility and capabilities in addition to providing all full channel-to-channel isolation. The Remote communicates directly to the and DCS via industry standard open-protocol networks. M-System s Remote also can be used as stand-alone distributed communicating with popular HMI software such as Citect, Intellution and Wonderware. The Remote can be located remotely in the field, or within an instrumentation cabinet such as test stands. The flexibility and scalability of M-System s Remote supports future system upgrades with full isolation between powercommunication- and between analog channels. Economical non-isolated analog modules are also selectable. Isolated analog modules provide high-performance signal conversion/conditioning and complete three-way plus channel-to-channel isolation. This ensures you a highly dependable system. Applications include: signal concentrator, data collection in flow and level monitoring, injection molding monitoring and control, test stands and prototyping, glass furnace temperature control, assembly line discrete ON/OFF, paint booth environment reporting, pharmaceutical processes. Broad Offering: Scalable and Flexible M-System, a specialist in signal conditioning, offers not only -0 ma / - V or discrete modules, but also temperature and other sensor inputs such as strain gauge, AC signals, pulse signals, etc. These modules can be mixed and mounted at any position on a backplane base. -position, 8-position and -position bases with single/dual channel analog modules are available for the. The is furthermore scalable from -position base, with - to -channel analog modules available. You can then take a minimum required number of modules and combine them to meet your specific system requirements. Redundant Communications: Reliable and Flexible Both R and supports optional redundant communications for mission critical applications. Dual network communication modules are optional. Additionally network interface modules can be placed without removing power. If you choose two different network protocols for the network modules, the remote s can be directly monitored by two different manufacturers systems. Reduce Downtime, Quick Installation All R and modules are field configurable via DIP Switches or via Configurator. DIP Switches configure the type, range and sensor failure modes (upscale or downscale). Communication module settings include baud rate and node address. Module replacement can be performed without programming or removing power. Simply remove the failed unit and replace with a good unit with the same DIP-Switch settings. No additional programming is required. Redundant Power for High Reliability Dual power supplies for the R and allow support for two different power sources. For example: the primary power can be supplied by 0 V or 0 VAC mains power while the secondary power module is connected to backup power from a UPS VDC system. Lower Total System Cost With its flexible and easy-to-use features, M-System s Remote ensures the toal cost reduction not only of hardware price but also of the time and additional resources such as specialized knowledge. Modular Solutions Designed for Open Network Systems Interface for Small Scale SCADA Interface for Large Scale SCADA Interface for LAN Ethernet Ethernet Gateway / Protocol Converter Field Network (Modbus, etc) Open Field Network (Modbus, etc) Open Field Network /DCS R Series R Series R Series R Series Remote Can Replace in -Based SCADA Systems System expansion can be done easiiy by directly connecting Remote and via a Field Network. The cost per channel is lower than using a. Easy system implementation without needing ladder programming M-System s wide variety of modules including programmable universal inputs are sure to meet your system requirements. Communication Module Field Network One Way Open Field Network (Modbus, etc) Network Module INTRODUCING REMOTE and other SCADA software R Series Better Way Remote Replacement for and DCS Appropriate type & numbers of modules can be chosen according to project needs. Minimization of total wiring cost through field network connectivity & remote distribution eliminating expensive point to point wires. M-System has a wide variety of modules including DC, T/C,, Potentiometer and more. CPU Panel Cable Signal Conditioner One Way Field Site A Power CPU Dual Redundant Power Supply (option) Panel Communication Module INTRODUCING REMOTE Field Network Dual Redundant Communication (option) Better Way Field Site B Signal Conditioner Power CPU Power Field Site C Field Site A Field Site B Field Site C

3 R7 NEW PRODUCT Compact all-in-one package Multi-channel, Mixed Signal Remote Wide selection of modules and network modules. Cost Lower Fieldbus Smaller Space Great flexibilities in number and type of signals: DC current/voltage, temperature, strain gauge, AC current/voltage, AC power, etc. Economical DC input module can handle fullyisolated points up to non-isolated points. Hot-swappable modules Dual redundant communication networks and power supplies 00 Vac isolation Palm-top size compact module can handle analog or discrete signals. The,network and power input modules are in one packege. Extension module Additional Functions Higher Integrity 7 types of open network protocols thr. analog channels per module thr. modules per node Typical Signals,, DC voltage/current, two-wire transmitter, potentiometer, strain gauge, AC power, PT/CT, pulse & discrete. Typical Output Signals DC voltage/current, totalized pulse & discrete LONWORKS discrete input or output module can be attachea to the base module. Analog and discrete signals can be mixed by combining a discrete module with an analog module. 00 Vac isolation for analog modules Fully isolated between, network and power input. Channel-to-channel isolation is also provided. Compact, Mixed Signal Remote Free combination of modules, network modules and power modules. Cost Lower R Series Fieldbus Additional Functions Smaller Higher Space Integrity Single analog module can handle fully-isolated points. Hot-swappable modules Dual redundant communication networks and power supplies 00 Vac isolation Space-saving DIN terminal block or heavy-duty screw terminal block selectable for types of open network protocols thr. analog channels per module thr. modules per node Typical Signals,, DC voltage/current, two-wire transmitter, potentiometer, CT, totalized pulse & discrete. Typical Output Signals DC voltage/current, totalized pulse & discrete Compact Size BASE MODULE Dry contact input, points NPN transistor output, points PNP transistor output, points DC voltage / ma input, points input, points input, poins DC voltage output, points DC current output, points Network Modbus DeviceNet CC-Link R7M-DA R7M-DCA R7M-DCB R7M-SV R7M-TS R7M-RS R7M-YV R7M-YS R7D-DA R7D-DCA R7D-DCB R7D-SV R7D-TS R7D-RS R7D-YV R7D-YS R7C-DA R7C-DCA R7C-DCB R7C-SV R7C-TS R7C-RS R7C-YV R7C-YS Compact, Multi-point Remote Economical all-in-one module for Modbus, CC-Link and DeviceNet Cost Lower Fieldbus Smaller Space 8/-point TC/DC input (isolated/non-isolated), 8- point /potentiometer input, -point discrete, -point totalized counter input modules Alarm contact output types of open network protocols 8 thr. analog channels per module EXTENSION MODULE Dry contact input, points NPN transistor output, points PNP transistor output, points Network Modbus DeviceNet CC-Link R7M-EA R7M-ECA R7M-ECB R7D-EA R7D-ECA R7D-ECB R7C-EA R7C-ECA R7C-ECB CC-Link discrete output modules (s R7C-DCA and DCB) can be extended only with the discrete output module (s R7C-ECA or DCB). Additional Functions Higher Integrity Typical Signals,, DC voltage, potentiometer, totalized pulse & discrete. Typical Output Signals Discrete Compact Size

4 R Multi-channel, Mixed Signal Remote Wide selection of modules and network modules. Great flexibilities in number and type of signals: DC current/voltage, temperature, strain gauge, AC current/voltage, AC power, etc. Economical DC input module can handle fully-isolated points up to non-isolated points. Hot-swappable modules and power supplies Dual redundant communication networks 00 Vac isolation MINIMUM SYSTEM CONFIGURATOR SOFTWARE RCON ON-LINE DOWNLOAD CABLE MCN-CON BASE mm / 8.8 in. (8-position base) 0 mm.7 in. 0 mm. in. MODULES POWER MODULE(S) NETWORK MODULE(S) The Power Supply Module is located at the right end, with Network Module inserted at its left. Network Module with incorporated power supply is available for small systems. Multiple modules can be mounted; No. at the extreme left end, No. and following modules to its right. M screw terminal block is used for modules. The removable terminal block is convenient for maintenance. Network Module and Power Supply Module in one housing. One module plus one Network Module with power supply is the minimum unit: Space-saving and economical solution. POWER MODULES R-PS R-PS NETWORK MODULES R-NE R-NM R-ND R-ND R-ND R-NP R-NC R-NC R-NC R-NL R-NL R-NF BASES R-BS R-BSW Rating 0V 70mA 0V.0A (double width) Capacity Modbus/TCP (Ethernet) Modbus Analog ch. DeviceNet Analog ch. Analog ch. PROFIBUS-DP CC-Link LONWORKS T-Link Same Protocol Ver. ; Analog ch. Ver. ; Analog ch. Ver. Network to Positions to Positions, free address Different Protocols Dual network communication modules are optional for mission critical applications. If you choose two different network protocols for the network modules, the remote s can be directly monitored by two different manufacturers systems. ANALOG INPUT MODULES Output R-TS (isolated) : K, E, J, T, B, R, S, C, N, U, L, P R-YV (isolated) Output: ±0V, ±V, ±V, 0 0V, 0 V, V, 0 V Accuracy: ±.0 C Accuracy: ±0.0% (±0.% for R-YV8) R-TS8 8 (isolated) Conversion rate: 0 ms or s R-YV8 8 (isolated) Response time: Max. 0. s (0 90%) R-RS (isolated) : Pt00, Pt000*, Pt0, Ni00, Ni000*, Output: 0mA Ni08.*, Cu0, Cu0 (*R-RS only) 8 (isolated) Accuracy: ±0.% R-RS8 Accuracy: ±.0 C Conversion rate: 0 ms or s DC Current R-YS (isolated) Response time: Max. 0. s (0 90%) : Pt00, -0 to +00 C Accuracy: ±0. C R-RS8A 8 (isolated) Resolution: 0.0 C Conversion rate: 0 ms or s : Open collector Rated load: Vdc R-SV, B (isolated) Pulse R-A : ±0V, ±V, ±V, 0 0V, 0 V, V, 0 V Max. frequency: 00Hz R-SV8, 8B 8 (isolated) Wide span input: ±0V, ±V, 0 0V, 0 V (R-SVxB) Totalized count: to 0000 R-SV8N 8 (non-isolated) : ±0V, ±V, 0 0V, 0 V, V R-SVN (non-isolated) ALARM MODULES R-SVA (isolated) : ±00mV, ±0mV, 0 00mV, 0 0mV, DC Millivolt 0 0mV R-SV8A 8 (isolated) (isolated) : ±0mA, 0 0mA, 0mA (0Ω) R-SS R-AT R-SS8 8 (isolated) : ±0mA, 0 0mA, 0mA (0Ω) R-AR DC Current R-SS8N 8 (non-isolated) : 0mA (0Ω) R-AV Setpoint range: -.00 to +.00% Deadband range: 0.00 to 00.00% R-SSN (non-isolated) : ±0mA, 0 0mA, 0mA (Ω) DC Current R-AS -0mA R-DS (isolated) : 0mA Supply output: 8V (Max. ma) -0mA with Excitation R-AD with Excitation R-DS8N 8 (non-isolated) : 0mA Supply output: V (Min. 00mA) R-MS (isolated) : 00Ω to 0kΩ Potentiometer R-MS8 8 (isolated) : 00Ω to 00kΩ DISCRETE MODULES Strain Gauge R-LC (isolated) : 0.0.0mV/V, 0.0.0mV/V CT R-CT (isolated) : 0 Aac, 0 Aac (RMS sensing) -point Dry Contact R-DA : Dry contact R-CTA, B (isolated) Clamp-on current sensor input CLSA: Sensing: Vdc AC Current 0 80Aac, 0 0Aac, 0 00Aac, 0 00Aac (R-CTxA) -point Contact with External Exc. R-DAA (external exc. for R-DAA) CLSB: 0 0Aac, 0 00Aac, 0 00Aac, 0 00Aac, R-CT8A, 8B 8 (isolated) 0 00Aac (R-CTxB) -point AC Contact R-DAB : 00 0Vac AC Voltage Watt Multi Power Pulse Totalized Pulse Encoder R-PT R-WT R-WTA R-WTB R-WT R-WTA R-WTB R-PA R-PAA R-PA R-PA (isolated) (isolated) system (isolated) (isolated) (isolated) : 0 0Vac, 0 0Vac System configuration: -phase/-wire, single-phase/- or -wire VT/CT input: 0Vac or 0Vac, A or A VT/Clamp-on current sensor input: 0Vac or 0Vac, 80A or 0A (R-WTA) / 0A or 00A (R-WTB) System configuration: -phase/-wire, single-phase/- or -wire VT/CT input: 0Vac or 0Vac, A or A VT/Clamp-on current sensor input: 0Vac or 0Vac, 80A or 0A (R-WTA) / 0A or 00A (R-WTB) Measurands: Active power / reactive power / power factor / frequency / active energy / reactive energy : Voltage pulse or open collector Max. frequency: 00kHz Totalized count: to : Dry contact Sensing: Max. V (internal or external) Max. frequency: 00Hz Totalized count: to 0000 : RS- line driver Max. frequency: 00kHz ANALOG OUTPUT MODULES -point Dry Contact -point Dry Contact -point Relay Output -point Open Collector Output -point Open Collector Output -point Open Collector Output -point Triac Output BCD CODE MODULES R-DAA R-DAA R-DC R-DCA R-DCA R-DCA R-DCB : Dry contact Ext. excitatlion: Vdc Output: Relay contact Rated load: 0Vac/0Vdc 0.A Output: Open collector Rated load: Vdc Output: Triac Rated load: 00 0Vac : BCD code, 7 digits ( channels/digit) BCD Code R-BAA Ext. excitation: Vdc Output: Open collector BCD Code Output R-BCA Rated Load: Vdc

5 R Compact, Mixed Signal Remote Free combination of modules, network modules and power modules. Single analog module can handle fully-isolated points. Hot-swappable modules Dual redundant communication networks and power supplies Space-saving DIN terminal block or heavy-duty screw terminal block selectable for 00 Vac isolation 8-POSITION BASE -POSITION BASE M. Screws Terminal Cover POWER MODULE NETWORK MODULE MODULES M. SCREW TERMINAL BLOCK modules are also available with a heavy-duty screw terminal block. The large terminal cover is easy for maintenance. Six -mm leadwires can be housed without needing to be squeezed into it. BASE POWER MODULE(S) The Power Supply Module is located at the left end, followed by slots for Network Modules, and then, 8 or slots for s. If you only need single communication, the th or 9th module can be added to the - or 8-position base. The slanted terminals are easily accessible even with high-density wiring. NETWORK MODULE(S) mm / 9. in. (8 modules) Re-Transmitted Output DC 0mA Re-Transmitted Output Network Re-Transmitted to 0 madc output is optional for local monitoring or recording. MODULES Mains 0/0 VAC UPS VDC Add another power module for a backup power source. 90 mm. in. 90 mm. in. POWER MODULES R-PSR R-PSK R-PSL R-NE R-NM R-ND R-ND R-NP R-NP R-NC R-NC R-NF BASES R-BS0 R-BS0* R-BS08 R-BS09* R-BS Same Protocol Vdc 00 0Vac 00 0Vac NETWORK MODULES Rating Network Modbus/TCP (Ethernet) Modbus DeviceNet DeviceNet, max. analog ch. PROFIBUS-DP PROFIBUS-DP, max. analog ch. CC-Link CC-Link, max. analog ch. T-Link Capacity modules modules 8 modules 9 modules modules *Single Network Module Different Protocols Dual network communication modules are optional for mission critical applications. If you choose two different network protocols for the network modules, the remote s can be directly monitored by two different manufacturers systems. ANALOG INPUT MODULES DC Current -0mA with Excitation CT Totalized Pulse R-TS R-TS RT-TS RT-TS R-RS RT-RS R-RS RT-RS R-SV R-SV R-SS R-SS R-DS R-DS RT-SV RT-SV RT-SS RT-SS RT-DS RT-DS RT-CT RT-CT R-PA RT-PA : K, E, J, T, B, R, S, C, N, U, L, P Accuracy: ±0. C Response time: Max. 0. s (0 90%) : Pt00, Pt000, Pt0 and Ni00, Ni08., Cu0, Cu0 Accuracy: ±0. C Response time: Max. 0. s (0 90%) : -0 +0V, V, etc. Accuracy: ±0.0% Response time: Max. 0. s (0 90%) : ±0mA, ±0mA, ±ma, 0 0mA, 0 0mA, 0mA, 0 ma, Accuracy: ±0.% Response time: Max. 0. s (0 90%) : 0mA Accuracy: ±0.0% Response time: Max. 0. s (0 90%) Supply output: 8V (max. ma) : 0 Aac Accuracy: ±0.%(at 00% input) Response time: Max. 0. s (0 90%) : Dry contact; Common negative Sensing: Max. V Max. frequency: 00Hz Response time: Max. 0. s ANALOG INPUT MODULES with RE-TRANSMITTED OUTPUT R-TSA R-RSA R-SVA DC Current R-SSA -0mA with Excitation R-DSA : K, E, J, T, B, R, S, C, N, U, L, P Output: 0mA : Pt00, Pt000, Pt0, Ni00, Ni08., Cu0, Cu0 Output: 0mA : ±0V, ±V, ±V, 0 0V, 0 V, V, 0 V Output: 0mA : ±0mA, ±0mA, ±ma, 0 0mA, 0 0mA, 0mA, 0 ma Output: 0mA : 0mA Supply output: 8V (max. ma) Output: 0mA ANALOG OUTPUT MODULES Output -0mA R-YV R-YV RT-YV RT-YV R-YS RT-YS R-YS RT-YS Totalized Pulse R- RT- DISCRETE INPUT MODULES Di Points R-DA RT-DA Di Points R-DA (Connector) DISCRETE OUTPUT MODULES Output Do Points R-DC RT-DC Do Points R-DC (Connector) ON-LINE DOWNLOAD Output: -0 +0V, V, etc. Accuracy: ±0.0% (-0 +0V) Response time: Max. 0. s (0 90%) Output: 0mA Accuracy: ±0.% Response time: Max. 0. s (0 90%) Output: Photo MOSFET relay; Each ch. independent Rated load: Vac/dc 0mA Max. frequency: 00 Hz Response time: Max. 0. s : Dry contact; Common per chs Sensing: V (V external supply selectable) Response time: Max. 0. s : Dry contact; Common negative Sensing: V (V external supply selectable) Response time: Max. 0. s Relay output: Common per chs Rated load: 0Vac/0Vdc 0.A Response time: Max. 0. s Open collector output: Common negative Rated load: 0V/0mA Response time: Max. 0. s CONFIGURATOR SOFTWARE RCON CABLE MCN-CON

6 R Compact, Multi-point Remote Economical all-in-one module for Modbus, CC-Link and DeviceNet 8/-point TC/DC input (isolated/non-isolated), 8-point /potentiometer input, -point discrete, -point totalized counter input modules Alarm contact output FRONT FRONT FRONT -POINT DISCRETE INPUT MODULE (connector type available) RM-A -POINT OPEN COLLECTOR OUTPUT MODULE (screw terminal block type available) RM-D -POINT UNIVERSAL INPUT MODULE RZMS-U9 -POINT DC/TC INPUT MODULE RC-GH REAR -POINT DC/TC INPUT MODULE RD-GH REAR -POINT DC/TC INPUT MODULE RM-GH REAR 8-POINT DC/TC INPUT MODULE, ISOLATED RMS-GH 8-POINT /POT INPUT MODULE RM-J TOTALIZED COUNTER INPUT MODULE RM-P Modbus Type : s or DC voltage, points; type and range is independently configurable for each channel. DC/TC, Points RM-GH Trigger : Dry contact, point DC/TC, 8 points Fully Isolated /POT, 8points Universal, points (isolated) Totalized Pulse, 8 points Discrete, points Discrete Output, points CC-Link, DeviceNet Type CC-Link DC/TC, points DeviceNet DC/TC, points RMS-GH RM-J RZMS-U9 RM-P RM-A RM-D RC-GH RD-GH : s or DC voltage, 8 points; type and range is independently configurable for each channel. Trigger : Dry contact, point Alarm Output: Photo MOSFET relay, point : or potentiometer resistance, 8 points; type and range is independently configurable for each channel. Trigger : Dry contact, point : DC voltage,, or potentiometer, points; type and range is independently configurable for each channel. Trigger : Dry contact, point Alarm Output: Photo MOSFET relay, point Totalized Pulse : Dry contact, points Discrete : Dry contact, 8 points (usable for totalizer) Discrete Output: Open collector, 8 points Trigger : Dry contact, point : Dry contact, points (M screw terminal block or connector) Common: All points Sensing: Approx. V (pull-up resistance kω Output: Open collector, points (M screw terminal block or connector) Common: All points Rated Load: V/0 ma (resistive load) : s or DC voltage, points; type and range is independently configurable for each channel. : s or DC voltage, points; type and range is independently configurable for each channel. CONFIGURATOR SOFTWARE RCON CABLE ON-LINE DOWNLOAD R Series GENERAL Power 00 0Vac, Vdc Dimentions W7 x H x D0mm Weight Approx. 00 g 0 00Ω, 0 00Ω, 0 kω, 0 0 kω Accuracy ±0.% RZMS-U9 Potentiometer (RM-J) ( C) Accuracy (%) JPt 00 (JIS '89) ±0. Pt 00 (JIS '89) ±0. Pt 00 (JIS '97, DIN, IEC7) ±0. Pt 0Ω (JIS '8) ±0. Ni 08.Ω ±0. Pt ±0. GENERAL Power 00 0Vac, Vdc Dimentions W7 x H8 x D.mm Weight Approx. 0g Potentiometer 0 00Ω, 0 00Ω, 0 kω ±0mV, ±mv, ±0mV, ±00mV, ±.0V, ±V, ±V, ±V (Rx-GH) T/C ( C) Accuracy ( C) (PR) ±0.* K ±0. E ±0.7 J ±0.7 T ±.0 B 0 80 ±0.7* R ±0.7* S ±0.7* C 0 +0 ±0.7 N ±0. U ±0. L ±0. P 0 9 ±0. * 00 C or higher / * 700 C or higher (Rx-GH) ±0V, ±V, ±V, ±0.8V, ±0.V, ±0mV, ±0mV T/C Accuracy ±0.% ( C) (PR) K E J T B R S C 0 +0 N U L P 0 9 (RMS-GH) (PR) ±. K ±. E ±0.8 J ±.0 T ±. B 0 80 ±7. R ±.8 S ±. C 0 +0 ±.9 N ±.9 U ±. L ±.0 P 0 9 ±.7 (RMS-GH) Accuracy ±0V ±0.0% (±0mV) T/C ( C) Accuracy ( C) ( C) Pt 00 (JIS '89) Pt 00 (JIS '97, DIN, IEC) Pt Pt Pt Pt Pt Pt 0Ω (JIS '8) JPt 00 (JIS '89) Ni Ni Ni 08.Ω Ni-Fe Cu 0 ( C) MCN-CON

RZXS CONFIGURATOR. (model: RZMSCFG) Users Manual. Contents 1. GENERAL...2

RZXS CONFIGURATOR. (model: RZMSCFG) Users Manual. Contents 1. GENERAL...2 RZXS CONFIGURATOR (model: RZMSCFG) Users Manual Contents 1. GENERAL...2 1.1 FEATURES OF RZMSCFG... 2 1.2 HARDWARE REQUIREMENTS... 3 1.3 REVISION HIST0RY... 3 2. GETTING STARTED...4 2.1 INSTALLING THE RZMSCFG...

More information

MODEL: MSRPAC PC Recorder Series

MODEL: MSRPAC PC Recorder Series Series PC RECORDER SOFTWARE PACKAGE Functions & Features Industrial recorder on Windows based PC MSR128-V6: 128-point analog/discrete & totalizied counter input recording at 0.5 sec. sampling cycle MSR128LS,

More information

Model R5H-RS PC CONFIGURATOR (model: R5HRSCFG)

Model R5H-RS PC CONFIGURATOR (model: R5HRSCFG) Model R5H-RS PC CONFIGURATOR (model: R5HRSCFG) Users Manual Contents 1. GETTING STARTED... 2 1.1 HARDWARE REQUIREMENTS... 2 1.2 INSTALLING THE R5HRSCFG... 2 1.3 STARTING UP THE R5HRSCFG... 2 2. OPERATING

More information

Model M3LR PC CONFIGURATOR (model: M3LRCON)

Model M3LR PC CONFIGURATOR (model: M3LRCON) Model M3LR PC CONFIGURATOR (model: M3LRCON) Users Manual Contents 1. GETTING STARTED... 2 1.1 HARDWARE REQUIREMENTS... 2 1.2 INSTALLING THE M3LRCON... 2 1.3 STARTING UP THE M3LRCON... 2 1.4 M3LR WITH OPTION

More information

MODEL: R3. Remote I/O R3 Series

MODEL: R3. Remote I/O R3 Series Remote I/O R3 Series R3 SERIES GENERAL SPECIFICATIONS Functions & Features Free combination of analog and discrete I/O Various open field bus (DeviceNet, Modbus, etc.) Direct sensor inputs Dual redundancy

More information

Model B6U / B6U-B PC CONFIGURATOR (model: B6UCON)

Model B6U / B6U-B PC CONFIGURATOR (model: B6UCON) Model B6U / B6U-B PC CONFIGURATOR (model: B6UCON) Users Manual Contents 1. GETTING STARTED... 2 1.1 HARDWARE REQUIREMENTS... 2 1.2 INSTALLING THE B6UCON... 2 1.3 STARTING UP THE B6UCON... 2 2. OPERATING

More information

MODEL: MSR2K-V6. PC Recorder Series

MODEL: MSR2K-V6. PC Recorder Series Series MSRpro SOFTWARE PACKAGE Ver.6 Functions & Features Industrial recorder on Windows based PC Stores, computes and plots in high speed multichannel input data of variety Client-server system Total

More information

R1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points)

R1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points) Remote I/O R1M Series THERMOCOUPLE & DC INPUT MODULE (16 points) MODEL MODEL & SUFFIX CODE SELECTION R1MGH2T MODEL Modbus protocol I/O TYPE GH2 : Thermocouple or DC input, 16 points FIELD TERMINAL TYPE

More information

R7X CONFIGURATOR. (model: R7CON) Users Manual , Minamitsumori, Nishinari-ku, Osaka JAPAN Tel: Fax:

R7X CONFIGURATOR. (model: R7CON) Users Manual , Minamitsumori, Nishinari-ku, Osaka JAPAN Tel: Fax: R7X CONFIGURATOR (model: R7CON) Users Manual 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Tel: +81-6-6659-8201 Fax: +81-6-6659-8510 http://www.m-system.co.jp/ E-mail: info@m-system.co.jp R7CON

More information

No.170. R7L Series I/O Type Addition. February 2009 I N S I D E

No.170. R7L Series I/O Type Addition. February 2009 I N S I D E M-System Newsletter February 2009 No.170 The CLIPBOARD is a monthly newsletter from M-System. It introduces to you new products, literature, product applications and other important information we pick

More information

MODEL: 73VR3100. Paperless Recording System

MODEL: 73VR3100. Paperless Recording System Paperless Recording System PAPERLESS RECORDER (Selectable input modules; TFT LCD display) Functions & Features 20 msec. storing rate with the combination of 8 analog and 8 discrete inputs 0.1 sec. storing

More information

R6-NC1 BEFORE USE... POINTS OF CAUTION. INSTRUCTION MANUAL CC-Link INTERFACE MODULE MODEL. (CC-Link Ver.1.10; for 16-point analog signals)

R6-NC1 BEFORE USE... POINTS OF CAUTION. INSTRUCTION MANUAL CC-Link INTERFACE MODULE MODEL. (CC-Link Ver.1.10; for 16-point analog signals) INSTRUCTION MANUAL CC-Link INTERFACE MODULE (CC-Link Ver..; for -point analog signals) MODEL R-NC BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received

More information

Remote I/O Modules EH-RIO2 Series

Remote I/O Modules EH-RIO2 Series Remote I/O Modules EH-RIO2 Series Fieldbus adapter: ProfiNET, EtherCAT, Modubus TCP / RTU, Profibus-DP, DeviceNet Separation of electronics module and terminal block for easy installation and maintenance

More information

DISCONTINUED MODEL Replaced with Model MSRPAC-2005

DISCONTINUED MODEL Replaced with Model MSRPAC-2005 Series PC RECORDER SOFTWARE PACKAGE MODEL MODEL & SUFFIX CODE SELECTION MODEL DISCONTINUED MODEL Replaced with Model MSRPAC-2005 Functions & Features Industrial recorder on Windows based PC MSR128-V3:

More information

500 Business Center Drive Pittsburgh, PA USA CAGE 1BGJ7. SwitchMaster R5000 Series Ultra-Compact Ganged A/B Switching System

500 Business Center Drive Pittsburgh, PA USA CAGE 1BGJ7. SwitchMaster R5000 Series Ultra-Compact Ganged A/B Switching System Market Central www.secureswitch.com 500 Business Center Drive Pittsburgh, PA 15205 USA 412.494.2800 CAGE 1BGJ7 SwitchMaster R5000 Series Ultra-Compact Ganged A/B Switching System July, 2014 COMPLETE 2

More information

LAUREL ELECTRONICS, INC.

LAUREL ELECTRONICS, INC. Description LAUREL ELECTRONICS, INC. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations Features Available for turbine flow meter pulse signals

More information

Veeder-Root brand Series C628 Rate Meter (C628-4XXX)

Veeder-Root brand Series C628 Rate Meter (C628-4XXX) Introduction Your Veeder-Root brand C628 Rate Meter is one model in a family of 1/8 DIN units which offers breakthrough display technology as well as easy-to-program single-line parameters. Designed to

More information

Power Transducers. Measuring most electrical parameters

Power Transducers. Measuring most electrical parameters Measuring most electrical parameters Wide range of power measuring transducers including AC volts, AC current, power factor, watts, vars and phase angles measurements. Multi power monitor has output options

More information

MODEL: R1M-P4. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

MODEL: R1M-P4. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.) PC Recorders Series PC RECORDER (4 totalized counter inputs, 8 contact inputs and outputs) Functions & Features Industrial recorder on PC Totalized counter inputs Counts stored in E 2 PROM Easy system

More information

LAUREL. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations ELECTRONICS, INC.

LAUREL. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations ELECTRONICS, INC. Description LAUREL ELECTRONICS, INC. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations Features Available for turbine flow meter pulse signals

More information

DISCONTINUED MODEL Replaced with Model MSRPAC-2006

DISCONTINUED MODEL Replaced with Model MSRPAC-2006 Series PC RECORDER SOFTWARE PACKAGE MODEL MSRPAC-2005 MODEL & SUFFIX CODE SELECTION MODEL MSRPAC-2005 DISCONTINUED MODEL Replaced with Model MSRPAC-2006 Functions & Features Industrial recorder on Windows

More information

MODEL: R3-NE1. Remote I/O R3 Series. ETHERNET INTERFACE MODULE (Modbus/TCP) 27.5 (1.08)

MODEL: R3-NE1. Remote I/O R3 Series. ETHERNET INTERFACE MODULE (Modbus/TCP) 27.5 (1.08) MODEL: R-NE Remote I/O R Series ETHERNET INTERFACE MODULE (Modbus/TCP) 7. (.8) 9 (.9) (.) mm (inch) MODEL: R-NE-[][] ORDERING INFORMATION Code number: R-NE-[][] Specify a code from below for each [] and

More information

M3S Series Super-space-saving Signal Conditioners. PC CONFIGURATOR SOFTWARE Model: M3SCFG. Users Manual

M3S Series Super-space-saving Signal Conditioners. PC CONFIGURATOR SOFTWARE Model: M3SCFG. Users Manual M3S Series Super-space-saving Signal Conditioners PC CONFIGURATOR SOFTWARE Model: M3SCFG Users Manual 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Tel: +81-6-6659-8201 Fax: +81-6-6659-8510

More information

R1M-GH BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PC RECORDER MODEL. (thermocouple or DC input, 16 points)

R1M-GH BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PC RECORDER MODEL. (thermocouple or DC input, 16 points) INSTRUCTION MANUAL PC RECORDER (thermocouple or DC input, points) MODEL RM-GH BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below.

More information

MTS-2000 USER S MANUAL

MTS-2000 USER S MANUAL MTS-2000 USER S MANUAL USER s MANUAL - March 2010 MTS-2000 METER TEST SYSTEM Pay special attention to the warnings and safety instructions that accompany the above symbol wherever it is found within this

More information

MODEL: R1M-GH. PC Recorders R1M Series

MODEL: R1M-GH. PC Recorders R1M Series PC Recorders Series PC RECORDER (thermocouple or DC input, 16 points) Functions & Features Industrial recorder on PC 16-point thermocouple or DC inputs Easy system expansion via Modbus RTU Recorded data

More information

Max. I/O units. consumption

Max. I/O units. consumption CJ2-Series CPU Units Modular PLC H236 Fast and Powerful CPUs for Any Task All CPU s support IEC61131-3 Structured text, Sequential Function Charts and ladder library helps to reduce your programming effort,

More information

MODEL: R1M-A1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

MODEL: R1M-A1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.) PC Recorders R1M Series PC RECORDER (contact input, 32 points) Functions & Features Industrial recorder on PC 32-point dry contact inputs Easy system expansion via Modbus RTU Recorded data exportable to

More information

Drawings. Model UT35A Digital Indicating Controller (UT35A-NNN-xx-xx/x) SD 05P01D41-05EN. External Dimensions. Panel Cutout Dimensions.

Drawings. Model UT35A Digital Indicating Controller (UT35A-NNN-xx-xx/x) SD 05P01D41-05EN. External Dimensions. Panel Cutout Dimensions. Drawings SD PD-EN Model A Digital Indicating Controller (A-NNN-xx-xx/x) [Style: S] External Dimensions Unit: mm (approx. inch) 96 (.78) (.) 6 (.6) Bracket Terminal cover (.79) 96 (.78) 9.6 (.6) 9.6 (.7).

More information

Piccola Smart Box Member of Modul MAS family

Piccola Smart Box Member of Modul MAS family Piccola Smart Box Member of Modul MAS family Pag. 1 of 6 Piccola Smart Box Rev.1.1 All Rights Reserved. No part of this document may be photocopied, reproduced, stored in a retrieval system, or transmitted,

More information

MODEL: R3-NFL1. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.) Remote I/O R3 Series

MODEL: R3-NFL1. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.) Remote I/O R3 Series Remote I/O R3 Series FL-net INTERFACE MODULE (OPCN-2, Ver.2. supported) Functions & Features FL-net (OPCN-2), Ethernet based, controller level network, compatible remote I/O 1 Mbps/1 Mbps cyclic transmission

More information

APPLICATION. Data acquisition Remote I/O I/O extension DESCRIPTION CONSTRUCTION

APPLICATION. Data acquisition Remote I/O I/O extension DESCRIPTION CONSTRUCTION RM 200 Modular I/O system open MODBUS Ethernet Plug-in I/O modules Suitable for CANopen/PROFIBUS-DP/MODBUS/Ethernet Modules for numerous sensors and signals 2, 4 or 8 channels, depending on module version

More information

Series S628 AC Volts/Amps (S628-3XXX) Veeder-Root brand. Technical Manual

Series S628 AC Volts/Amps (S628-3XXX) Veeder-Root brand. Technical Manual Introduction Your Veeder-Root brand S628 AC Volts/Amps is one model in a family of 1/8 DIN units which offers breakthrough display technology as well as easy-to-program single-line parameters. Designed

More information

LAUREL ELECTRONICS, INC.

LAUREL ELECTRONICS, INC. LAUREL ELECTRONICS, INC. Laureate RTD Temperature Panel Meter / Controller Features Factory calibrated for 100Ω platinum, 10Ω copper & 120Ω nickel RTDs 2, 3 or 4-wire connection with lead resistance compensation

More information

Digital Lighting Systems, Inc.

Digital Lighting Systems, Inc. Digital Lighting Systems, Inc. Four Channel Dry Contacts Relays Switch Pack DMX512 compatible USER'S MANUAL -UM User's Manual - Page 1 GENERAL DESCRIPTION The is a 4-channel DMX-512 compatible electro-mechanical

More information

R3-NE1 ETHERNET INTERFACE MODULE MODEL. Remote I/O R3 Series. (Modbus/TCP)

R3-NE1 ETHERNET INTERFACE MODULE MODEL. Remote I/O R3 Series. (Modbus/TCP) Remote I/O R Series ETHERNET INTERFACE MODULE (Modbus/TCP) MODEL R-NE MODEL & SUFFIX CODE SELECTION R NE MODEL POWER INPUT K : V AC L : V AC R : V DC N : No power supply * *. Choose N (no power supply)

More information

STATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

STATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free Instruction Manual Model 1582-45L Data Switch September 2010, Rev A REMOTE LOCAL SWITCH STATUS SELECT REMOTE LOCAL LOCAL SELECT CHANNEL SELECT POWER MODEL 1582 SWITCH CROSS TECHNOLOGIES, INC. Data, drawings,

More information

LAUREL. Laureate Dual-Channel Pulse Input Totalizer With Two Independently Scalable Input Channels & Presets ELECTRONICS, INC. Features.

LAUREL. Laureate Dual-Channel Pulse Input Totalizer With Two Independently Scalable Input Channels & Presets ELECTRONICS, INC. Features. Description LAUREL ELECTRONICS, INC. Laureate Dual-Channel Pulse Input Totalizer With Two Independently Scalable Input Channels & Presets Features Frequencies up to 1 MHz Totals stored in non-volatile

More information

V E2B Snap-in I/O Module

V E2B Snap-in I/O Module V200-18-E2B Snap-in I/O Module The V200-18-E2B plugs directly into the back of compatible Unitronics OPLCs, creating a selfcontained PLC unit with a local I/O configuration. Features 16 isolated digital

More information

-Camille Bauer Div. of Absolute Process Instruments, Inc. Phone: Fax: J-1

-Camille Bauer Div. of Absolute Process Instruments, Inc. Phone: Fax: J-1 Solving Your Y Application Challenges! Phone: 800-462-4040 Fax: 800-949-7502 www.apicb.com 1220 American Way Libertyville, IL 60048 USA Copyright Absolute Process Instruments, Inc. 02/03 CBSK2003A J-1

More information

MICRO SERIES PROCESS DISPLAYS LARGE DIGIT MODELS

MICRO SERIES PROCESS DISPLAYS LARGE DIGIT MODELS The MICRO SERIES PROCESS DISPLAYS LARGE DIGIT MODELS Mighty-5 DPM MODELS Micro-P & Mighty-1 Mighty-1 Micro-P ELECTRO-NUMERICS, INC. Introduction The Electro-Numerics family of Digital Panel Meters and

More information

CQM1 I/O Terminal Block Conversion Adapter. Easy and secure replacement by reusing the I/O terminal block wiring.

CQM1 I/O Terminal Block Conversion Adapter. Easy and secure replacement by reusing the I/O terminal block wiring. CQM1 I/O CSM_CJ1W-AT4 DS_E_1_1 Easy and secure replacement by reusing the I/O terminal block wiring You can replace CQM1(H) Series with CJ Series, efficiently using your assets. Time for wiring works and

More information

Options. 24-VDC service power supply. RUN output. No Yes No 24 VDC 70 W NX-PD7001

Options. 24-VDC service power supply. RUN output. No Yes No 24 VDC 70 W NX-PD7001 NX-Series Power Supply Unit CSM_NX-PA_PD_DS_E_2_2 Powerful power supply unit to supply stable power to the NX-series controller. Stable power supply is available from the NX-series CPU Unit to each I/O

More information

LAUREL. Laureate RTD Temperature Panel Meter / Controller ELECTRONICS, INC. Features. Description. Specifications

LAUREL. Laureate RTD Temperature Panel Meter / Controller ELECTRONICS, INC. Features. Description. Specifications LAUREL ELECTRONICS, INC. Laureate RTD Temperature Panel Meter / Controller Features Factory calibrated for 100Ω platinum, 10Ω copper & 120Ω nickel RTDs 2, 3 or 4-wire connection with lead resistance compensation

More information

PIM-Mini Pulsed Current Source Operation Manual

PIM-Mini Pulsed Current Source Operation Manual PIM-Mini Pulsed Current Source Operation Manual Directed Energy, Inc. 1609 Oakridge Dr., Suite 100, Fort Collins, CO 80525 (970) 493-1901 sales@ixyscolorado.com www.ixyscolorado.com Manual Document 7650-0007

More information

PCM-7140 Pulsed Current Source Operation Manual

PCM-7140 Pulsed Current Source Operation Manual PCM-7140 Pulsed Current Source Operation Manual Directed Energy, Inc. 1609 Oakridge Dr., Suite 100, Fort Collins, CO 80525 (970) 493-1901 sales@ixyscolorado.com www.ixyscolorado.com Manual Document 7650-0031

More information

Power Supply Input voltage 20.4VDC to 28.8VDC with less than 10% ripple Max. current consumption See Note 1

Power Supply Input voltage 20.4VDC to 28.8VDC with less than 10% ripple Max. current consumption See Note 1 Vision OPLC V130-33-TR6/V130-J-TR6 Technical Specifications The Unitronics V130-33-TR6/V130-J-TR6 offers the following onboard I/Os: 8 Digital Inputs, configurable via wiring to include 2 Analog (current/voltage)

More information

PMDX-170 Slotted Optical Sensor

PMDX-170 Slotted Optical Sensor PMDX-170 Slotted Optical Sensor User s Manual Date: 20 May 2009 PMDX Web: http://www.pmdx.com 9704-D Gunston Cove Rd Phone: +1 (703) 372-2975 Lorton, VA 22079-2366 USA FAX: +1 (703) 372-2977 PMDX-170_Manual_10.doc

More information

V E1B Snap-in I/O Module

V E1B Snap-in I/O Module V200-18-E1B Snap-in I/O Module The V200-18-E1B plugs directly into the back of compatible Unitronics OPLCs, creating a selfcontained PLC unit with a local I/O configuration. Features 16 isolated digital

More information

Power Supply Input voltage 20.4VDC to 28.8VDC with less than 10% ripple Max. current consumption See Note 1

Power Supply Input voltage 20.4VDC to 28.8VDC with less than 10% ripple Max. current consumption See Note 1 Vision OPLC V130-33-TR20/V130-J-TR20 Technical Specifications The Unitronics V130-33-TR20/V130-J-TR20 offers the following onboard I/Os: 12 Digital Inputs, configurable via wiring to include 2 Analog (current/voltage)

More information

DIGITAL INDICATING CONTROLLER

DIGITAL INDICATING CONTROLLER DB1000 SERIES DIGITAL INDICATING CONTROLLER The DB1000 series is a 96 96mm digital indicating controller with the indicating accuracy of ±0.1% and the control cycle of approximately 0.1 seconds. Various

More information

Photoelectric Sensor

Photoelectric Sensor Photoelectric Sensor Small General-purpose Photoelectric Sensor with Built-in Power Supply Built-in amplifier accepts wide supply voltage range. Slim, space-saving construction measures only 50 x 50 x

More information

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4. Flat Proximity Sensor EK-F CSM_EK-F_DS_E Flat Capacitive Sensor with a Thickness of Only mm Flat Sensor with excellent space efficiency. (Model with built-in Amplifier is only mm thick.) Direct mounting

More information

Photoelectric Sensor

Photoelectric Sensor Photoelectric Sensor Small General-purpose Photoelectric Sensor with Built-in Power Supply Built-in amplifier accepts wide supply voltage range. Slim, space-saving construction measures only 50 x 50 x

More information

C160 Wall-/Pipe Mounted Universal Process Indicator

C160 Wall-/Pipe Mounted Universal Process Indicator Data sheet DS/ EN Rev. I Wall-/Pipe Mounted Universal Process Indicator reliable process indicator, wherever it s needed High visibility LED display the clearest view of your process status 0.1% measurement

More information

TC Type Range Conformity Error. J -210 C to +760 C (-347 F to F) ±0.09 C (±0.16 F) K -244 C to C (-408 F to F) ±0.1 C (±0.

TC Type Range Conformity Error. J -210 C to +760 C (-347 F to F) ±0.09 C (±0.16 F) K -244 C to C (-408 F to F) ±0.1 C (±0. LAUREL ELECTRONICS, INC. Laureate Thermocouple Panel Meter / Controller Features Factory calibrated for thermocouple types J, K, T, E, N, R, S Entire range of each thermocouple in one scale Highly accurate

More information

Wall-/Pipe Mounted Universal Process Indicator

Wall-/Pipe Mounted Universal Process Indicator Data Sheet SS/_8 Wall-/Pipe Mounted Universal Process Indicator High visibility LED display the clearest view of your process status 0.1% measurement accuracy precise indication of process measurement

More information

PWR. Power Module Slots

PWR. Power Module Slots INSTRUCTION MANUAL ETHERNET INTERFACE MODULE (Modbus/TCP) MODEL BEFORE USE... Thank you for choosing M-System. Before use, please check the contents of the package you received as outlined below. If you

More information

BEFORE USE... POINTS OF CAUTION. INSTRUCTION MANUAL PNP TRANSISTOR OUTPUT MODULE, 16 points (MECHATROLINK-I / -II, short circuit protection)

BEFORE USE... POINTS OF CAUTION. INSTRUCTION MANUAL PNP TRANSISTOR OUTPUT MODULE, 16 points (MECHATROLINK-I / -II, short circuit protection) INSTRUCTION MANUAL PNP TRANSISTOR OUTPUT MODULE, 16 points (MECHATROLINK-I / -II, short circuit protection) R7ML-DC16D MODEL R7ML-DC16D BEFORE USE... Thank you for choosing M-System. Before use, please

More information

TABLE OF CONTENTS INTRODUCTION. 3. Analog Input Analog Output Digital Input Digital Output OPERATIONAL DESCRIPITON.. 7 PROGRAMMING AND INITIAL SETUP.

TABLE OF CONTENTS INTRODUCTION. 3. Analog Input Analog Output Digital Input Digital Output OPERATIONAL DESCRIPITON.. 7 PROGRAMMING AND INITIAL SETUP. DIVERSIFIED HEAT TRANSFER SERIES 700 STEAM GENERATOR CONTROLLER INSTRUCTION MANUAL VISIT OUR WEBSITE AT SIGMACONTROLS.COM SERIES 700 DHT STEAM GENERATOR MANUAL 042514 2 TABLE OF CONTENTS INTRODUCTION.

More information

SECURE/NONSECURE LED SIGN USER MANUAL

SECURE/NONSECURE LED SIGN USER MANUAL SECURE/NONSECURE LED SIGN USER MANUAL December 2012 Wall Mount Part Number: 51-01198 1U Rack Mount Part Number: 51-01196 500 Business Center Drive, Pittsburgh, PA 15205 Phone: (412) 494-2800, Fax: (412)

More information

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L MONITORED DEVICE

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L MONITORED DEVICE O P E R A T I N G I N S T R U C T I O N S IRB-RET UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L 3 2 5-2 0 1 6 MONITORED DEVICE 4564 Johnston Parkway, Cleveland, Ohio 44128 P. 800 426 9912 F. 216 518 9884

More information

S800 I/O ABB Automation

S800 I/O ABB Automation S800 I/O 3BCNIIT F HW02-S800-V0102 Rev. 02/01 Page 1 S800 I/O S800 I/O 3 : Fieldbus Communication Interface (FCI) I/O Module Module Termination Unit (MTU), Compact or Extended version 3BCNIIT F HW02-S800-V0102

More information

IOX-4. Installation Instructions. AXS-100 I/O Expander 1. INTRODUCTION 2. SPECIFICATIONS 3. MOUNTING DE6314 1

IOX-4. Installation Instructions. AXS-100 I/O Expander 1. INTRODUCTION 2. SPECIFICATIONS 3. MOUNTING DE6314 1 AXS-100 I/O Expander 1. INTRODUCTION The is an input / output expander for the AXS-100 access control panel. It contains eight analog inputs and eight dry contact relays output. Up to four boards may be

More information

INTRINSICALLY SAFE INSTRUMENTATION FOR HAZARDOUS AREAS

INTRINSICALLY SAFE INSTRUMENTATION FOR HAZARDOUS AREAS INTRINSICALLY SAFE INSTRUMENTATION FOR HAZARDOUS AREAS SHORT FORM 2002 SERIES D1000 Intrinsically Safe Galvanic Isolators SERIES D1000, for DIN Rail Mounting, provide the most simple and cost effective

More information

EASON TECHNOLOGY. IO8 & IO24 Break-Out Module

EASON TECHNOLOGY. IO8 & IO24 Break-Out Module EASON TECHNOLOGY IO8 & IO24 Break-Out Module p/n 50-00180-01 Revision1.2 Eason Technology, Inc. 7975 Cameron Dr. Bldg 300 Windsor, CA 95492 Phone (707) 837-0120 FAX (707) 837-2742 http://www.eason.com

More information

Omega and Red Lion team-up!

Omega and Red Lion team-up! Omega and Red Lion team-up! Red Lion History Started in 1972 Sensors and OEM Products Panel Meters started in 1976 Red Lion Today 3 International Sales Offices Over 100,000 Square Feet Full Surface Mount

More information

MODEL: SC100. Single Loop Controller Series. MULTI-FUNCTION PID CONTROLLER (color LCD with touch-panel) MODEL: SC100 [1]0 [2][3]

MODEL: SC100. Single Loop Controller Series. MULTI-FUNCTION PID CONTROLLER (color LCD with touch-panel) MODEL: SC100 [1]0 [2][3] Single Loop Controller Series MULTI-FUNCTION PID CONTROLLER (color LCD with touch-panel) 44 (5.67) 7 (.83) * mm (inch) *Selectable with option code /4: 400 mm /6: 600 mm Language blank: Japanese /E: English

More information

Features various encoder interfaces and controls multiple analog servo drives at high speeds

Features various encoder interfaces and controls multiple analog servo drives at high speeds CK3W Axial Interface Unit CK3W-AX Features various encoder interfaces and controls multiple analog servo drives at high speeds CK3W-AX Features One CK3W-AX Unit controls up to four axes Analog input type

More information

Discrete I/O connected direct onto. Input and Output Function Blocks, including Flexible Function Block (FFB) for logic execution

Discrete I/O connected direct onto. Input and Output Function Blocks, including Flexible Function Block (FFB) for logic execution Discrete I/O connected direct onto Profibus-PA Input and Output Function Blocks, including Flexible Function Block (FFB) for logic execution Power, Control and I/O integrated in the same hardware Mix Profibus

More information

TSD-DA28 2x8 Balanced Line Distribution Amplifier

TSD-DA28 2x8 Balanced Line Distribution Amplifier 2x8 Balanced Line Distribution Amplifier 1 Description The Atlas Sound 2x8 distribution amplifier is designed to provide clean, isolated signal distribution locally or to remote locations. The unit allows

More information

Powered Roller Controller for DeviceNet

Powered Roller Controller for DeviceNet PRC-620-090 TECHNICAL DATA Description The Holjeron Powered Roller Controller for use with DeviceNet has the features needed to handle up to four zones in a material handling system. A Brushless DC Powered

More information

Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3.

Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3. Data Sheet T 6493 EN TROVIS 6400 Automation System TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and

More information

E2EY. A Proximity Sensor for Aluminum, Brass and Other Non-ferrous Metals. Iron Is Not Detected. Aluminum-detecting Proximity Sensor

E2EY. A Proximity Sensor for Aluminum, Brass and Other Non-ferrous Metals. Iron Is Not Detected. Aluminum-detecting Proximity Sensor Aluminum-detecting Proximity Sensor EEY CSM_EEY_DS_E_5_1 A Proximity Sensor for Aluminum, Brass and Other Non-ferrous Metals. Iron Is Not Detected. Non-ferrous metals, such as aluminum and brass, are detected.

More information

G3FM. Model Number Structure. Ordering Information. Solid State Relays. Model Number Legend. List of Models

G3FM. Model Number Structure. Ordering Information. Solid State Relays. Model Number Legend. List of Models Solid State Relays CSM DS_E_5_3 100-μA-max. Leakage Current, No Bleeder Resistor Required Reduces wiring work by 60% when combined with the PFY-08- PU Push-In Plus Socket (according to actual OMRON measurements).

More information

Energy Management Modular Universal Utility Meter and Power Analyzer Type WM24-96

Energy Management Modular Universal Utility Meter and Power Analyzer Type WM24-96 Energy Management Modular Universal Utility Meter and Power Analyzer Type WM24-96 Class 1 (active energy) Class 2 (reactive energy) Accuracy 0.5% RDG (current/voltage) Universal utility meter and power

More information

TC /100Base-T Ethernet Fiber Optic Switch User's Manual. 4 Ethernet 10/100Base-T Auto-Sensing Twisted Pair Ports with RJ-45 Connectors

TC /100Base-T Ethernet Fiber Optic Switch User's Manual. 4 Ethernet 10/100Base-T Auto-Sensing Twisted Pair Ports with RJ-45 Connectors TC3705 10/100Base-T Ethernet Fiber Optic Switch User's Manual 1. Features 4 Ethernet 10/100Base-T Auto-Sensing Twisted Pair Ports with RJ-45 Connectors 1 Fiber Optic 100Base-FX Port MDI/MDIX Auto Detection

More information

73VR3000 PAPERLESS RECORDER MODEL. Paperless Recording System. (selectable input modules) MODEL & SUFFIX CODE SELECTION 73VR3000 R3 TYPE

73VR3000 PAPERLESS RECORDER MODEL. Paperless Recording System. (selectable input modules) MODEL & SUFFIX CODE SELECTION 73VR3000 R3 TYPE Paperless Recording System PAPERLESS RECORDER (selectable input modules) MODEL & SUFFIX CODE SELECTION MODEL 144 (5.67) MODEL LANGUAGE E : English N : Japanese POWER INPUT M2: 100 240V AC R : 24V DC A

More information

-Camille Bauer. Phone: Fax: American Way Libertyville, IL USA. Application Challenges! Sig. Cond.

-Camille Bauer. Phone: Fax: American Way Libertyville, IL USA. Application Challenges! Sig. Cond. Solving Your Y Application Challenges! Phone: 800-942-0315 Fax: 800-949-7502 www.apicb.com 1220 American Way Libertyville, IL 60048 USA KINAX Copyright Absolute Process Instruments, Inc. 11/04 215 Loop-Powered

More information

Tornado F-5. Motor Backspin Detect Relay And Probe For F-5 Motor Controller

Tornado F-5. Motor Backspin Detect Relay And Probe For F-5 Motor Controller Tornado F-5 Motor Backspin Detect Relay And Probe For F-5 Motor Controller Tornado F-5 Motor Backspin Detection Relay And Probe Revision 8.1 Change Log: Rev 8.1 Apr 24 2012 JNesbitt@GPS-US.co GPS updates

More information

MODEL: 73VR1100. [3] OPTIONS blank: none /Q: With options (specify the specification) Paperless Recording System

MODEL: 73VR1100. [3] OPTIONS blank: none /Q: With options (specify the specification) Paperless Recording System Paperless Recording System PAPERLESS RECORDER (remote I/O modules) Functions & Features 100 msec. storing rate for the max. of 64 points (1 station) with the R3-NE1 module Graphic image view helps to recognize

More information

R1M-GH BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PC RECORDER MODEL. (thermocouple or DC input, 16 points)

R1M-GH BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PC RECORDER MODEL. (thermocouple or DC input, 16 points) INSTRUCTION MANUAL PC RECORDER (thermocouple or DC input, points) MODEL BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below. If

More information

Veeder-Root brand Series S628 Strain Gauge (S628-6XXX)

Veeder-Root brand Series S628 Strain Gauge (S628-6XXX) Introduction Your Veeder-Root brand S628 Strain Gauge is one model in a family of 1/8 DIN units which offers breakthrough display technology as well as easy-to-program single-line parameters. Designed

More information

iologik 4000 Series (M) Modules

iologik 4000 Series (M) Modules iologik 4000 Series (M) s Remote I/O modules Features and Benefits I/O expansion without a backplane Active communication with MX-AOPC UA Server Supports SNMP v1/v2c Easy configuration with Modular ioadmin

More information

VariTrans P Standard-Signal Isolators

VariTrans P Standard-Signal Isolators VariTrans Standard-Signal Isolators Warranty Defects occurring within 5 years from delivery date shall be remedied free of charge at our works (carriage and insurance paid by sender). The professional

More information

G3NE. Model Number Structure. Solid State Relays. Model Number Legend. Compact, Low-cost, SSR Switching 5 to 20 A

G3NE. Model Number Structure. Solid State Relays. Model Number Legend. Compact, Low-cost, SSR Switching 5 to 20 A Solid State Relays CSM DS_E_4_1 Compact, Low-cost, SSR Switching 5 to 20 A Wide load voltage range: 75 to 264 VAC. Both 100-V and 200-V loads can be handled with the same model. Dedicated, compact aluminum

More information

Power Supply Input voltage 20.4VDC to 28.8VDC with less than 10% ripple Max. current consumption See Note 1

Power Supply Input voltage 20.4VDC to 28.8VDC with less than 10% ripple Max. current consumption See Note 1 Vision OPLC V350-35-TRA22 Technical Specifications The Unitronics V350-35-TRA22 offers the following onboard I/Os: 12 Digital Inputs, configurable via wiring to include 2 Analog, 2 PT100/TC and 1 HSC/Shaftencoder

More information

iopac 8500 Series Rugged modular RTU controllers Overview Programmable Controllers High Sampling Rate Analog Input Prerecord Feature

iopac 8500 Series Rugged modular RTU controllers Overview Programmable Controllers High Sampling Rate Analog Input Prerecord Feature Programmable Controllers iopac 8500 Series Award-winning Product Rugged modular RTU controllers Dedicated ARM (RISC) CPUs for the main system and each I/O module Millisecond timestamp granularity for digital

More information

SIGNAL CONVERTERS ELECTRONIC INSTRUMENTATION FOR INDUSTRY. Small catalogue. Tel. (+34)

SIGNAL CONVERTERS ELECTRONIC INSTRUMENTATION FOR INDUSTRY. Small catalogue.   Tel. (+34) SIGNAL CONVERTERS LARGE displays PANEL METERS ELECTRONIC INSTRUMENTATION FOR INDUSTRY Small catalogue 2013 www.fema.es Tel. (+34) 93.729.6004 info@fema.es SMALL CATALOguE 2013 ELECTRONIC INSTRUMENTATION

More information

M-System s. 17 years of successful sales, 480,000 total units sold! selectable. Mixed Signal. Mixed Signal. Compact, Mixed Signal

M-System s. 17 years of successful sales, 480,000 total units sold! selectable. Mixed Signal. Mixed Signal. Compact, Mixed Signal M-System s 0-0 EC-Z -00 Rev. 000 years of successful sales, 0,000 total units sold! Freely communicates with host devices without needing extra programming. Compliant with major open networks regularly

More information

CJ1W-PTS/PDC/PH41U/AD04U

CJ1W-PTS/PDC/PH41U/AD04U CJ-series Process Analog I/O Unit A Single Unit Handling All Types of Inputs such as Temperature Sensor Inputs and Analog Signal Inputs (e.g., 4 to 20 ma or 1 to 5 V) A Unit supports four input channels,

More information

DLS-E2 TELEMETERING UNIT BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL MODEL. (16 contact inputs & 16 open collector outputs)

DLS-E2 TELEMETERING UNIT BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL MODEL. (16 contact inputs & 16 open collector outputs) INSTRUCTION MANUAL TELEMETERING UNIT ( contact inputs & open collector outputs) MODEL DLS-qE DLS-E BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received

More information

Solid State Relays with Failure Detection Function

Solid State Relays with Failure Detection Function Solid State Relays with Failure Detection Function CSM DS_E_2_1 Refer to Safety Precautions for All Solid State Relays. Detects failures in SSR used for heater temperature control and simultaneously outputs

More information

Energy Management Modular Energy meters Type EM2-96

Energy Management Modular Energy meters Type EM2-96 Energy Management Modular Energy meters Type EM2-96 Product Description µp-based modular energy meter with a built-in configuration key-pad. The energies are both partial and total counted. The housing

More information

TC1880 Series. 4/5/6/8 Channel RS-232 FIBER OPTIC MICRO MUX User's Manual

TC1880 Series. 4/5/6/8 Channel RS-232 FIBER OPTIC MICRO MUX User's Manual Series 4/5/6/8 Channel RS-232 FIBER OPTIC MICRO MUX MODEL: S/N: DATE: Notice! Although every effort has been made to insure that this manual is current and accurate as of date of publication, no guarantee

More information

MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL

MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL VISIT OUR WEBSITE SIGMACONTROLS.COM MYR QLC MANUAL 013114 2 TABLE OF CONTENTS INTRODUCTION 3 Ordering Information Specifications Features WIRING

More information

IO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs

IO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs IO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs The IO-DI8-TO8 and IO-DI8-TO8-L are I/O expansion modules that can be used in conjunction with specific Unitronics OPLC controllers. The

More information

Z-PC Line REMOTE I/O SYSTEM. Cost-effective & easy to manage TCP-IP

Z-PC Line REMOTE I/O SYSTEM. Cost-effective & easy to manage TCP-IP Z-C Line 100% Made & Designed in Italy TC-I Cost-effective & easy to manage w w w. s e n e c a. i t Z-C Line MODBUS I/O SYSTEM Z-C Line is a modular system able to manage from simple to complex applications

More information

Power Supply Input voltage 20.4VDC to 28.8VDC with less than 10% ripple Max. current consumption See Note 1

Power Supply Input voltage 20.4VDC to 28.8VDC with less than 10% ripple Max. current consumption See Note 1 Vision OPLC V130-33-TR34 Technical Specifications The Unitronics V130-33-TR34 offers the following onboard I/Os: 22 Digital Inputs, configurable via wiring to include 2 Analog and 3 HSC/Shaft-encoder Inputs

More information

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel I/O Relay CSM DS_E_4_4 Slim-styled I/O Relay Saves Space in Panel SPST-NO, SPST-NC, and SPDT contact forms available for output (SPST-NO only for input). Ultra-slim housing measuring 29 (W) x 0 (D) x 2

More information