1 BC-PRO O& &T Man nual With Rem mote Station Mine Moni itoring Manual Part Number September 22, 2009 AMERICAN MINE RESEARCH, INC P.O. BOX 234, ROCKY GAP, VA

2 PH FAX TABLE OF CONTENTS TITLE PAGE Table of Content.2 Introduction..3 General..3 Operation Details 4 Equipment & Instrumentation.5 Equipment Operation.5 Fault Logic...6 Operator Interface.7 Main Screen 7 Roller Screens 8 Dust Control Screen.8 Input Screen..9 Analog Screens.10 System Screen 11 Roller Configure Screens.12 System Configure Screen 13 Analog Configure Screens. 14 Speed Sensor Mounting Troubleshooting..17 General..17 Communication..18 PanelView...19 PLC 19 Block Diagrams 21 2

3 General Operation The BC PRO BELT CONTROL PRO serves as a belt starter control unit and a MC 4000 monitoring system remote. The belt starter function combines many of the belt head inputs and outputs in one unit to simplify installation and troubleshooting. When the BELT CONTROL PRO is connected to the monitoring system communication line, all information about the status of the belt head that is available at the BELT CONTROL PRO is sent to the monitor system master station as well. The front panel mounted PanelView display provides the user interface to gather the status and to perform the configuration of the BELT CONTROL PRO. In general, the interface allows the user to calibrate and configure the BELT CONTROL PRO to match the belt head system installation. It also allows the user to determine whether the belt is running or stopped, is it sequence, slip, pull cord, etc? The BELT CONTROL PRO operates from 120 VAC and has a re chargeable battery back up for the atmosphere monitoring system. The atmosphere monitoring system will operate for 8 hours during power off conditions to provide information to the monitor system master station and power to sensors connected to it. Inductive type proximity sensors provide speed inputs to perform belt sequence, under speed, true slip, and dust suppression at the belt head. Because the BELT CONTROL PRO is microprocessor based, very quick and accurate calculations are made to determine that the belt head system is performing within the configured limits. All speeds sensor inputs are used to generate belt system roller speeds and theses are used to configure the belt head system. These roller speeds may be viewed on the PanelView display from the main screen. The BELT CONTROL PRO is used as to monitor system remote, belt roller system speeds are also sent to the monitor system master station. The true slip function, when compared to the normal belt head slip, is far superior because it is very precise and it protects the belt during startup. The normal belt head slip function is nothing more than under speed switch. It is very inaccurate and it is bypassed during belt startup. True slip is performed by monitoring the belt drive roller speed and comparing it to the belt roller speed. The ratio of the belt speed to drive roller speed if fixed and has been calculated by the BELT MASTER during configuration of the unit. Even during startup, if the present belt speed is less than the calculated belt speed value as determined from the drive roller speed and the preset percentage slip, the belt is slipping and the belt is stopped. Belt under speed is determined by using the drive roller speed sensor input instead of the belt roller speed sensor input. The BELT CONTROL PRO uses the sequence speed sensor input to monitor the receiving belt speed and stops the dumping belt if the receiving belt is not moving fast enough. A speed sensor is also mounted to the dumping belt trough roller to determine that the belt is loaded with material. This speed sensor input is used by the BELT CONTROL PRO to operate the dust suppression system. Variation from perfect belt head operation is allowed and the deviation percentages for belt slip, drive roller under speed, sequence belt under speed, and dust suppression roller speed is entered via the front PanelView display. 3

4 Operation Details The conventional belt starter control switches located on the BELT CONTROL PRO front panel provide the primary means for controlling the belt. The locking type emergency STOP switch interrupts the belt start control circuit to insure the belt will stop when it is pushed. The BELT CONTROL PRO also monitors the STOP switch to de energize the belt start relay, terminate the present control sequence, and initialize the BELT CONTROL PRO for the next start sequence. When the BELT CONTROL PRO stops the belt for any reason the belt may not restarted until the STOP time has expired. This is necessary to allow fluid coupling drives to drain. When the AUTO/OFF/MANUAL switch is placed to the OFF position, the same events occur as described above for the STOP switch. Note: During operation of the BELT CONTROL PRO, the BELT DRIVE STATUS MENU may be used to display the belt drive status at reason for belt stoppage. When the AUTO/OFF/MANUAL switch is placed to the AUTO position, the BELT CONTROL PRO checks the sequence belt for proper speed and begins the PRESTART period. During the PRESTART period, the BELT CONTROL PRO activates the audible/ visual alarm to warn personnel that the belt will start at the end of the PRESTART period. At the end of the PRESTART period, the audible/visual alarm is deactivated. Next begins the START period of the belt start sequence if all other start conditions are satisfied. During the START period, the BELT CONTROL PRO begins monitoring the belt for true slip. At the end of the start period (or as soon as the drive roller has reached normal running speed), the BELT CONTROL PRO begins monitoring the drive roller for under speed. When the AUTO/OFF/ MANUAL switch is placed to the MANUAL position, the BELT MASTER ignores the sequence belt condition and the belt is ready to begin the PRESTART period of the belt start sequence, if all other start conditions are satisfied. At the end of the PRESTART period of the belt start sequence, if all other start conditions are satisfied the same as in AUTO, audible/visual alarm is de activated, the belt starts, and the BELT MASTER begins monitoring the belt for true slip. The belt is still monitored for true slip and under speed as described above for the AUTO switch position. Note: The length of the prestart, start periods and stop periods are user defined and are a part of the BELT MASTER configuration. Note: If the sequence speed sensor does read as required for AUTO! In MANUAL, the belt will stop to prevent false operation of belt system conditions. The JOG button (See Figure 8) is a PanelView touch button that will start the belt after the PRESTART period by ignoring the sequence belt condition and all other status inputs except the remote and deluge switches. The belt is still monitored for true slip and under speed as described above for the MANUAL switch position. Note: The JOG button must be pushed continuously to perform the JOG function and JOG belt function can be performed only with the AUTO/OFF/MANUAL switch in the MANUAL position. 4

5 Equipment and Instrumentation Motor 1 Motor 2 Speed Sensor 1 Drive Roller RPM Speed Speed Sensor 2 Belt Roller RPM Speed Speed Sensor 3 Sequence Roller RPM Speed Speed Sensor 4 Dust Roller RPM Speed Equipment Operation The BC PRO uses Allen Bradley MicroLogix 1100 PLC and AMR LS 3040 speed sensors. Belt speed is monitored by two speed sensors (Drive Roller and Belt Roller). The speed sensors are used to detect a slip condition when the belt is starting or under load. The Sequence Roller speed sensor monitors belt speed of the next sequencing belt. If the next sequencing belt stops the BC PRO will stop the belt drive and prevent a GOB or boney pile on the sequencing belt that would cause the sequencing belt not to start. The Dust Roller RPM speed sensor is part of the dust suppression system of the belt drive. If the belt is under load and the Dust Roller speed sensor is reading the preset RPM, then the BC PRO will set an output relay that will start a set of water sprayers. The BC PRO has 18 digital inputs. Four are reserved for internal monitoring of Auto, Manual, CB PRO faults, and belt status open/closed. Two are for monitoring Remote Line and Deluge. Four are for belt rollers (Drive, Belt, Sequence, & Dust). Two are spill switches (Head & Tail). 1 is Fluid Coupling Over Temperature, Belt Misalignment, and GOB switch. Lastly are three unassigned or configurable channels. The BC PRO has four analog inputs. All four are unassigned or configurable channels. The BC PRO has six digital outputs. All six are reserved for internal CB PRO reset, Horn, Dust suppression, Belt status and Start commands 1 & 2. 5

6 Fault Logic The BC PRO is programmed with fault logic so that if any of the faults listed below occur, both CB PROs will shut off. The fault must be reset to restart the belt again: CB PRO faults. Deluge opened. GOB switch tripped. Belt Misalignment switch tripped. Other faults after being cleared will restart belt: Remote switch open Fluid Coupling Over Temperature Any of the three (3) spare digital channels, if enabled. 6

7 Operator Interface (PanelView550) The BC PRO uses an Allen Brady PanelView550 Touch Screen operator interface. This interface gives the operator the capability to reset faults and calibrate speed rollers. This section describes how to use the PanelView The Main screen shows common details for belt status (See Figure 1) Figure 1 Main Screen 1. Roller details use graphical needle gauges to show RPMs of roller and a status area for belt OK or LOW. 2. Reset button is for resetting faults that can be reset by BC PRO (other faults would be CB PRO or Ground Faults) 3. Quick Reference Buttons are used to GoTo a general detail screen for the Digital or Analog channels. 4. Belt Status shows the current status of the belts. 5. Selected Screen indicates the screen that will be displayed if the GoTo screen button is touched. 6. Scroll Up & Down Buttons allow you to scroll through all of the root screens. 7

8 The Roller Screens show the time delay and calibration set points (See Figure 2) Figure 2 Drive Roller Details The Dust Control Screen shows the time on/off delay, calibration set points, and a button for turning the controls On or Off (See Figure 3) Figure 3 Dust Control Details 1. Time On Delay shows the time that the dust suppression system will be delayed before it will turn On and the Time Off Delay shows the delay timee that the system will continue to run after the signal to shut off is received. 8

9 2. Control Button allows you to turn on or shut off the dust suppression system. The Inputs Screen shows digital status of the PLC inputs (See Figure 4) Figure 4 PLC Input Details 1. CB Open shows Open or Closed 2. Spill Tail shows Ok or Faulted 3. CB Fault shows Ok or Faulted 4. Deluge shows Ok or Fire 5. Remote showss Ok or Open 9

10 The Analog Screens show the details of the analog channel (1 4) and the channels can be custom named (See Figure 5) Figure 5 Analog Screen 1. The Calibration Set Point is the scaled high set pointt of the channel. 2. The Alarm Type is set to Alarm Only or Kill Belt Enabled. This allows you to shut off the belts if a high limit alarm is critical to belt operation. 3. The High Alarm Set Point & Alarming On or Off shows the high limit set point. This limit is activated by the Alarming On or Alarming Off function. 4. The Low Alarm Set Point & Alarming On or Off shows the low limit set point. This limit is activated by the Alarming On or Alarming Off function. 5. The Time is located in the middle of the high and low Alarming On/Off display and is the time delay for both set points before the alarms or kill belt takes affect. 10

11 The System Screen is for manual jogging the belt, accessing system configuration screens, factory setting screen, and allows you to clean the screen (See Figure 6) Figure 6 System Screen 1. The Jog Button is used to manually jog the belt: The selector switch on the front of the BC PRhave jogged the must be set to Manual. Touch and continue to touchh the Jog Button until you belt to the desired location. 2. The Configuration Screen Button takes you to the Allen Bradley default PanelView system configuration screen. This allows you to change factory settings such as IP address, etc (Seee PanelView 550 Manual). 3. The Clean Screen Button opens a blank screen with only one small button thatt will return you to the System Screen. This allows you to clean the screen without touching unwanted buttons. 4. The System Screen has a Selected Screen option thatt is not found on other screens (below Status). By scrolling through the select screens with the up and down arrows you will find the new screen called Main CNFG. If selected, this will take you to the main details configuration screen of the BC PRO. You can then edit (enable, disable, etc.) the inputs and outputs. Upon selecting the Main CNFG, you will be prompted to enter the password (9281). This will display the Main CNFG screen. From thiss screen you will be able to go to all digital and analog channel input or output screens. Note that the Selected Screens has changed to reflect the configuration screens, for example; Inputs is now Inputs CNFG. To return to regular operation screens selectt the Main RTN screen. 11

12 The Roller Configure screens allow you to change the percent deadband, time delay, enable/disable, and calibrate the roller (Seee Figure 7). Figure 7 Roller Configure 1. The Percent Deadband Button is used to change the deadband percentage is the precent which the roller speed is considered out of range and the time delay starts counting. Percent Deadband can be set from 1 to 50 percent. Example of percent deadband: If set to 5% and the roller is calibrated to 100 RPM, the processor will nott see a problem unless the RPM is below 95 RPM because 5% of 100 RPM is 95 RPM. 2. The Calibration Button is used to calibrate the speedd sensor at maximum RPM. To calibrate, operate the belt and once the belt is up to max RPM and touch the Calibration Button. The value for the max speed is recorded and automatically scaled for percent deadband. 3. The Time Delay Button is used to set the time delay before a faultt condition is detected. This value can be set from 1 to 120 seconds. 4. The Enable Button is used to enable or disable the roller. 12

13 The System Configure screen is used to set the horn time, hold time, and motor start type (See Figure 8). Figure 8 System Configure The Hold Time Button is used to adjust the holding time after the last motor starter starts till the BC For the standard BC PRO to CB PRO application, the motor starts must be set to momentary (Moment) start. Other starter systems may need to be setup for maintained close (Latch) start. PRO starts examining the rollers, digital, analog, etc. for faults before shutting off the belts. The Motor 1 & 2 Buttons are used to set the type of motor starts that are required to start the motors. The Horn Time Button is used to set the amount of time thee horn will sound before the belts will start. The time can be set between 5 and 360 seconds. 13

14 The Analog Configuration Screens allow you to change the analog channel name and units, alarm time delay, alarm only or kill belt, set alarm high or low limits, and calibrate the analog channel. These screens also have a help button for calibration problems (See Figure 9). Figure 9 Analog Configuration Screen 14

15 Speed Sensor Mounting It is recommended that a welded key stock target (See Figure 10) be added to the rollers to be monitored. Targets consisting of chisel notches are not recommended because they do not present a well defined target for the speed sensor. The drawing below shows a bottom roller with a single target being used to monitor belt speed and sequence. However, a single target may be added to one of the outside rollers of the top roller assembly with the same results. It is important that the belt always be in contact with the roller when monitoring belt speed and sequence. Select a roller near the end of the receiving belt to monitor sequencee and a roller near the endd of the dumping belt to monitor belt speed. Monitoring the drive roller is accomplished by adding a single target to the side of the drive roller. The dust suppression sensor target should be addedd to the top roller assembly trough roller. The belt should be in contact with the roller when the belt is loaded and the belt should move away from the roller when the belt is empty. Figure 10 Key Stock Mounting Details The speed sensors can be mounted to the roller structures using the AMR supplied angle iron and tie should be perpendicular to the roller surface and spaced 1/ /8 to 1/4 inch from the roller target. Insure that the sensor does not come in contact with the belt or wraps. Weld the angle iron to the structure such that the sensor does not vibrate. The sensor end roller. 15

16 Figure 11 Top & Bottom Roller Assembly 16

17 Troubleshooting BC PRO 1) Insure that 120 VAC is supplied to the Remote Unit TB3-1&2, the AC Power ON switch is ON and the AC lamp is ON. 2) Insure that the voltage output measured across both batteries is greater than 22 VDC and the DC Power ON switch is ON 3) Verify that the DC Power ON lamp turns ON when the Power ON Reset switch is momentarily pressed. If the DC Power ON lamp comes ON and then turns OFF when the Power ON Reset switch is released, place the Kill Enable/Disable switch to Disable and repeat step 4 again. 4) If the DC Power ON lamp stays ON, the Master Station has commanded the Remote power OFF and placing the Kill switch to Disable bypasses the Master Station command to Kill power to the Remote. Be sure to place the Kill Enable/Disable switch to Enable once the Master Station has commanded the Remote power to ON. 5) After the DC Power ON lamp comes ON and stays ON, verify the following conditions: a) The SixNet Media Converter power ON LED is ON; b) The voltage measured across both batteries is either increasing (which means the batteries are being charged) or the battery voltage is greater than 27 VDC (which means the batteries are fully charged). This confirms the Power Supply PC board battery changing circuitry is functional. c) Measure 24 VDC between pins 1 and 2 of J4 on the Gateway PC board. This confirms the Power Supply PC board 24 VDC power supply circuitry is functional. d) The Gateway Ethernet Interface Module Activity LED should blink every 10 seconds even though there may not be an Ethernet connection. e) Confirm the presence of 24 VDC at pins 1 and 2 of each Gateway PC board OUT port connectors. If the voltage is not present at all of the port connectors, remove the plug from that port to eliminate the possibility of a cable short and measure the port pins again. NOTE: The Gateway PC board will remove power from the OUT port if the DS1 (POWER) switch is ON and the current draw is greater than 400 milliamps. If the voltage is still not available at the port, either the power has been commanded OFF from the Master Station or the port power control IC has failed. In the event the Gateway does remove 24 VDC from the output port, it will notify the Master Station. 17

18 6) Sixnet Media Converter Confirm 24 VDC is connected to P1 and (-) of the Sixnet module power connector and the Power LED is ON. Confirm that the Outby Tx/Rx and the Inby Tx/Rx fiber optic cables are connected to the module fiber ports. If there is ethernet activity on the fiber cable, the port ACT LEDs should blink. Confirm that one of the Sixnet Media Converter module RJ45 ethernet ports is connected to the Ethernet Gateway PC board. The activity LED associated with that RJ45 port should blink in unison with the fiber port activity LED. 7) Ethernet Gateway PCBoard Insure that the Gateway PC board is installed properly according to the Installation (Section 3) of this manual. Insure that the Gateway PC board has 24 VDC at connector J4-1 and J4-2. Confirm the presence of 24 VDC at pins 1 and 2 of each Gateway PC board OUT port connectors. If the voltage is not present at all of the port connectors, remove the plug from that port to eliminate the possibility of a cable short and measure the port pins again. NOTE: The Gateway PC board will remove power from the OUT port if the DS1 (POWER) switch is ON and the current draw is greater than 400 milliamperes. If the voltage is still not available at the port, either the power has been commanded OFF from the Master Station or the port power control IC has failed. In the event the Gateway does remove 24 VDC from the output port, it will notify the Master Station. Verify the Ethernet cable is connected, the processor LNK (green LED) is ON and the processor ACT (yellow LED) is blinking. When the Gateway receives Modbus TCP/IP requests it sends a request to the three output ports causing the TX LEDs to blink. If a sensor or remote connected to the Output Port responds to the request for data, the corresponding RX LED will blink and the TXIN LED will blink. If a sensor or remote fails to respond to request, move the port output cable to another port to test if the port has failed. The Gateway PC board monitors each OUT port COMM (+) and COMM ( ) line for abnormal (wires shorted to each other or wire/s shorted to 24 VDC or to GND) conditions. If a short condition exits, the Gateway PC board will disable communication to that port until the short condition is removed. The Gateway PC board will notify the Master Station that communications with the port has been disabled. If a sensor or remote fails to respond to request, move the port output cable to another port. 18

19 8) Using the Master Station If a particular branch of the monitoring system is experiencing communications problems, use the Analog, Digital and Control data returned from the Gateway to determine the problem source. Observe the Control Channel Status and insure the Port is enabled and Power is ON. Use the Digital Channel Status to observe the Port Short and Port Open states. Use the Digital Channels Status to confirm AC Power ON and Battery Status. Use the Analog Channels Data to verify the Power Supply voltage is between 15 VDC and 28 VDC. Use the Analog Channels Data to verify the Port Bias voltage is between 0.15 VDC and 0.45 VDC. Use the Analog Channels Data to verify the Port Level voltage is greater than 0.5 VDC. Use the Analog Channels Data to verify the Port Draw current is consistent with the devices being powered from the port. Use the Analog Channels Data to verify the Port Errors is not excessive. 9) PanelView 550 Terminal does not power up. o Improper connection to power source. o Incorrect input voltage level. No communications with MicroLogix. o Communications (COMM) fault. o PLC is not in run mode. No communications with PLC but COMM LED is active. o PanelView is trying to communicate with a PLC at a different address. 10) MicroLogix PLC Controller Status LED Indicators o Power Off = No input power, or power error condition Green = Power On o Run Off = Not executing the user program Green = Executing the user program o Fault Off = No fault detected Red Flashing = Application fault detected Red = Controller hardware faulted o Force Off = No forces installed (normal) Amber = Forces installed 19

20 11) Expansion I/O Modules Module Status LED State o On = Proper Operation o Off = Module Fault Cycle power. If condition persists, replace the module. More detail about troubleshooting the BC-PRO can be found in the Master Manual (Part # ) 20

21 21

22 22

23 23

PS-4100 POWER SUPPLY MANUAL

PS-4100 POWER SUPPLY MANUAL PS-4100 POWER SUPPLY MANUAL Manual Part Number 180-0573 December 7, 2006 TABLE OF CONTENTS TITLE PAGE Table of Contents... 2 List Of Figures... 3 1. Introduction... 4 1.0. General... 4 1.1. Features...

More information

MC CO MODBUS ADDRESSABLE SENSOR

MC CO MODBUS ADDRESSABLE SENSOR MC-4210 - CO MODBUS ADDRESSABLE SENSOR Manual Part Number 180-0545A March 31, 2003 PAGE 1 TABLE OF CONTENTS TITLE PAGE Table of Contents...2 List Of Figures...4 1. Introduction...5 1.0. General...5 1.1.

More information

Model HM-535 Power Supply Installation and Service Instructions

Model HM-535 Power Supply Installation and Service Instructions Model HM-535 Power Supply Installation and Service Instructions 430-535 0104 2004 Heritage MedCall, Inc SENTRY INSTALLATION & SERVICE INSTRUCTIONS POWER SUPPLY UNIT Model HM-535 IMPORTANT SAFETY INSTRUCTIONS

More information

QUICK START. ATEQ F620 Version 1.0. Reference: MR-28300A-U. (Photo no contractual)

QUICK START. ATEQ F620 Version 1.0. Reference: MR-28300A-U. (Photo no contractual) QUICK START ATEQ F620 Version 1.0 (Photo no contractual) Reference: MR-28300A-U REVISIONS OF THE ATEQ F620 USER MANUAL Due to continuing improvements, the information contained in this user manual, the

More information

G9SX-GS. Safety Guard Switching Unit. A Safety Measure for Hazardous Operations That Does Not Lower Productivity. Auto Switching Function

G9SX-GS. Safety Guard Switching Unit. A Safety Measure for Hazardous Operations That Does Not Lower Productivity. Auto Switching Function Safety Guard Switching Unit CSM DS_E_6_1 A Safety Measure for Hazardous Operations That Does Not Lower Productivity Two functions support two types of application: Auto switching: For applications where

More information

QCPort Cover Control Trouble Shooting Guide

QCPort Cover Control Trouble Shooting Guide QCPort Cover Control Trouble Shooting Guide Technical Document Feb. 2006 Page 1 of 14 QCPort Cover Control Description Door Defeater Address/Options Bucket Latch Breaker Actuator Hasp Lock Keypad Overlay

More information

Sidewinder Pumps Inc. AC Timer/Controller

Sidewinder Pumps Inc. AC Timer/Controller Sidewinder Pumps Inc. AC Timer/Controller Page 1 of 12 Rev 032417 Table of Contents 1. Warnings-------------------------------------------------------------------------------------------------- 3 1.1.

More information

MODBUS TCP MODULE INSTRUCTIONS. for use with WSIQ2/WSE

MODBUS TCP MODULE INSTRUCTIONS. for use with WSIQ2/WSE INSTRUCTIONS MODBUS TCP MODULE for use with WSIQ2/WSE WorldWide Electric Corporation Phone: 1-800-808-2131 Fax: 1-800-711-1616 www.worldwideelectric.net Product Compatibility This communications module

More information

INSTRUCTION MANUAL STATION CONTROLLER SC1000 MOTOR PROTECTION ELECTRONICS, INC.

INSTRUCTION MANUAL STATION CONTROLLER SC1000 MOTOR PROTECTION ELECTRONICS, INC. INSTRUCTION MANUAL STATION CONTROLLER SC1000 MOTOR PROTECTION ELECTRONICS, INC. 2464 Vulcan Road, Apopka, Florida 32703 Phone: (407) 299-3825 Fax: (407) 294-9435 Revision Date: 9-11-08 Applications: Simplex,

More information

SMART SHOT CONTROLLER FLUID USERS GUIDE

SMART SHOT CONTROLLER FLUID USERS GUIDE SMART SHOT CONTROLLER FLUID USERS GUIDE Pg. 2 SMART SHOT CONTROLLER FEATURES 3 SMART SHOT CONTROLLER FEATURES 3 SMART SHOT CONTROLLER CONFIGURATIONS 4 FLOAT/SENSOR WIRING 5 TOP AND BOTTOM FLOAT/SENSOR

More information

INTRINSICALLY SAFE DUPLEXER PROTECTION. ELECTRONICS, INC Vulcan Road Apopka, Florida MOTOR INSTRUCTION MANUAL

INTRINSICALLY SAFE DUPLEXER PROTECTION. ELECTRONICS, INC Vulcan Road Apopka, Florida MOTOR INSTRUCTION MANUAL INTRINSICALLY SAFE DUPLEXER INSTRUCTION MANUAL MOTOR PROTECTION ELECTRONICS, INC. 2464 Vulcan Road Apopka, Florida 32703 Phone: Website: (407) 299-3825 www.mpelectronics.com Operating Program Revision:

More information

MSR Level Control Relay Module Operating Instructions for Level Control Relay Module Model: MSR

MSR Level Control Relay Module Operating Instructions for Level Control Relay Module Model: MSR Operating Instructions for Level Control Relay Module Model: MSR MSR Operation Instructions Rev. Apr 07 Page 1/8 1. Note Please read and take note of these operating instructions before unpacking and commissioning.

More information

Vision Fitness TF20-TF40-T40 Frame with Classic / Elegant / Touch Console Service Manual

Vision Fitness TF20-TF40-T40 Frame with Classic / Elegant / Touch Console Service Manual Vision Fitness TF20-TF40-T40 Frame with Classic / Elegant / Touch Console Service Manual 1 TABLE OF CONTENTS CHAPTER 1: SERIAL NUMBER LOCATION 1.1 Serial Number Location - TF20 Frame.....3 1.2 Serial Number

More information

Abstract. GLV User Manual 1

Abstract. GLV User Manual 1 GLV User Manual 1 Abstract This user manual is a high level document that explains all operational procedures and techniques needed to operate the GLV system in a safe and effective manner. Anyone operating

More information

Allen-Bradley PLCs. 100 Programmable Controller Processor Unit -Catalog Nos LPI01, -LP102, -LP103, -LP104 SLC TM. The Unit

Allen-Bradley PLCs. 100 Programmable Controller Processor Unit -Catalog Nos LPI01, -LP102, -LP103, -LP104 SLC TM. The Unit PRODUCT DATA SLC TM 100 Programmable Controller Processor Unit -Catalog Nos. 1745-LPI01, -LP102, -LP103, -LP104 The SLC 100 programmab/e Contro"er The SLC 100 Programmable Controller is easy to program,

More information

SC2000 MOTOR PROTECTION ELECTRONICS, INC. INSTRUCTION MANUAL. Phone: (407) Fax: (407) Vulcan Road Apopka, Florida 32703

SC2000 MOTOR PROTECTION ELECTRONICS, INC. INSTRUCTION MANUAL. Phone: (407) Fax: (407) Vulcan Road Apopka, Florida 32703 SC2000 INSTRUCTION MANUAL MOTOR PROTECTION ELECTRONICS, INC. 2464 Vulcan Road Apopka, Florida 32703 Phone: (407) 299-3825 Fax: (407) 294-9435 Operating Program Revision: 10 Revision Date: 1-9-12 STATION

More information

Installation and Operation Manual Back-UPS BR900G-RS

Installation and Operation Manual Back-UPS BR900G-RS Installation and Operation Manual Back-UPS BR900G-RS Inventory Safety bu001a This unit is intended for indoor use only. Do not operate this unit in direct sunlight, in contact with fluids, or where there

More information

SECTION SOLID-STATE REDUCED VOLTAGE STARTERS

SECTION SOLID-STATE REDUCED VOLTAGE STARTERS SECTION 26 29 13.16 PART 1 - GENERAL 1.1 THE REQUIREMENT A. General: The CONTRACTOR shall provide solid-state reduced voltage motor starters, complete and operable, in accordance with the Contract Documents.

More information

Installation and Operation Back-UPS Pro 900

Installation and Operation Back-UPS Pro 900 Us er Documentation Installation and Operation Back-UPS Pro 900 Inventory bu001a User Documentation (2) Safety and General Information Inspect the package contents upon receipt. Notify the carrier and

More information

HGM9580 Bus Tie Bus Parallel Unit USER MANUAL. Smartgen Technology

HGM9580 Bus Tie Bus Parallel Unit USER MANUAL. Smartgen Technology HGM9580 Bus Tie Bus Parallel Unit USER MANUAL Smartgen Technology This manual is suitable for HGM9580 bus tie bus parallel unit only. Clarification of notation used within this publication. SIGN INSTRUCTION

More information

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS MAINTENANCE MANUAL EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS SPECIFICATIONS*... 2 INTRODUCTION... 3 DESCRIPTION...

More information

Back-UPS RS 550 Installation & Operation

Back-UPS RS 550 Installation & Operation Back-UPS RS 550 Installation & Operation Inventory Safety Do not install the UPS in direct sunlight, in excessive heat, humidity, or in contact with fluids. bu001a Do not connect a laser printer or hair

More information

Zenith DS9000 Dispensing System

Zenith DS9000 Dispensing System Page Date: 04/2009 Zenith DS9000 Dispensing System Installation & Operation Manual Page 2 Table of Content Introduction... 3 Control Specification... 4 Wiring Diagram... 5 Wiring Instructions... 6 Field

More information

SS2200 Remote Controller

SS2200 Remote Controller SS2200 Remote Controller General Purpose, DC Voltage General The SS2200 Remote Controller is a microprocessor-based programmable controller specifically designed to control single line and dual line centralized

More information

Table of Contents 1. Overview Installation...6

Table of Contents 1. Overview Installation...6 (2003-01-31) Table of Contents 1. Overview...1 1.1. Introduction... 1 1.2. Product Description... 1 1.2.1. Mechanical Actuator Assembly with M2CP Electrical Enclosure... 1 1.2.2. Variable Frequency Controller

More information

CORTEX INDUSTRIAL SYSTEM CONTROLLER Dancer Position Control. Instruction Manual Model CORTEX-C00

CORTEX INDUSTRIAL SYSTEM CONTROLLER Dancer Position Control. Instruction Manual Model CORTEX-C00 CORTEX INDUSTRIAL SYSTEM CONTROLLER Dancer Position Control Instruction Manual Model CORTEX-C00 Table of Contents 1. General Description...2 2. Specifications...4 2.1 Electrical...4 2.2 Physical...5 3.

More information

Innovative Circuit Technology Ltd. Digital Series Power Supply Instruction Manual

Innovative Circuit Technology Ltd. Digital Series Power Supply Instruction Manual Innovative Circuit Technology Ltd. Digital Series Power Supply Instruction Manual 855-317-000 Rev 2.0 Feb 2018 Copyright 2018 Innovative Circuit Technology Ltd. All rights reserved. No part of this publication

More information

Making Hazardous Operations Safe and Productive

Making Hazardous Operations Safe and Productive NEW Safety Guard Switching Unit G9SX-GS Making Hazardous Operations Safe and Productive Making Hazardous Operations Safe and Productive This new addition to the model of Flexible Safety Unit G9SX series

More information

Installation and Operation Back-UPS Pro 900

Installation and Operation Back-UPS Pro 900 software Us er Documentation Installation and Operation Back-UPS Pro 900 Inventory Connect the Battery bu001a User Documentation (2) Safety and General Information Inspect the package contents upon receipt.

More information

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual Document 481200 VGD-100 Vari-Green Drive Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install,

More information

DPS Telecom Your Partners in Telecom Management Networks

DPS Telecom Your Partners in Telecom Management Networks DPS Telecom Your Partners in Telecom Management Networks Operation Guide LR24 Relay Card Table of Contents Overview...1 Table of Contents...1 Typical Relay Applications...2 Shipping List....2 Installation...2

More information

SC2000 MOTOR PROTECTION ELECTRONICS, INC. INSTRUCTION MANUAL. (407) Phone: Website:

SC2000 MOTOR PROTECTION ELECTRONICS, INC. INSTRUCTION MANUAL. (407) Phone: Website: SC2000 INSTRUCTION MANUAL MOTOR PROTECTION ELECTRONICS, INC. 2464 Vulcan Road Apopka, Florida 32703 Phone: Website: (407) 299-3825 www.mpelectronics.com Operating Program Revision: 12 Revision Date: 8-27-14

More information

PLC Fundamentals. Module 2: Hardware and Terminology. Academic Services Unit PREPARED BY. August 2011

PLC Fundamentals. Module 2: Hardware and Terminology. Academic Services Unit PREPARED BY. August 2011 PLC Fundamentals Module 2: Hardware and Terminology PREPARED BY Academic Services Unit August 2011 Applied Technology High Schools, 2011 ATE1212 PLC Fundamentals Module 2: Hardware and Terminology Module

More information

Quick Start Guide TS A

Quick Start Guide TS A Quick Start Guide TS 930 125-630A DANGER HAZARD OF ELECTRICAL SHOCK, EXPLOSION, OR ARC FLASH Read and understand this quick start guide before installing and operating the transfer switch The installer

More information

Contents. Product name and model... 1 Specifications... 1 Appearance and Size... 1 Function Summary and Button Definition... 2 Function Summary...

Contents. Product name and model... 1 Specifications... 1 Appearance and Size... 1 Function Summary and Button Definition... 2 Function Summary... Contents Product name and model... 1 Specifications... 1 Appearance and Size... 1 Function Summary and Button Definition... 2 Function Summary... 2 Button Definition... 2 Assembly... 2 Function Area Distribution...

More information

Installation and Operation Back-UPS BR1000G-IN / BR1500G-IN

Installation and Operation Back-UPS BR1000G-IN / BR1500G-IN Installation and Operation Back-UPS BR1000G-IN / BR1500G-IN Important Safety Information Read the instructions carefully to become familiar with the equipment before trying to install, operate, service

More information

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections Data sheet 3379_en_B 1 Description PHOENIX CONTACT 2015-07-14 2 Features Media converters provide

More information

Bad Start Check all Power and Ground connections.

Bad Start Check all Power and Ground connections. Bad Start Check all Power and Ground connections. 1. Check weld head power & ground connections to the adapter cable or pig-tail adapter. 2. Check power & ground connections at the power supply. 3. Check

More information

MULTISPENSE 900 W/TOUCHSCREEN CONTROLLER MODULE Page 3-1. Table Of Contents. Section Description Page #

MULTISPENSE 900 W/TOUCHSCREEN CONTROLLER MODULE Page 3-1. Table Of Contents. Section Description Page # MULTISPENSE 900 W/TOUCHSCREEN CONTROLLER MODULE Page 3-1 Table Of Contents Section Description Page # 3. Multispense 900 W/Touchscreen Controller Module... 3-2 3.1 Description... 3-2 3.1.1 Front Panel

More information

FG-3000 Digital Force Gauge Operation Manual

FG-3000 Digital Force Gauge Operation Manual FG-3000 Digital Force Gauge Operation Manual Operators should wear protection such as a mask and gloves in case pieces or components break away from the unit under test. Whether the unit is ON or OFF,

More information

Trouble Shooting Leveling Control Box Electric Jacks. Touch Pad LED Probable Cause Solution

Trouble Shooting Leveling Control Box Electric Jacks. Touch Pad LED Probable Cause Solution Trouble Shooting Leveling Control Box 140-1224 Electric Jacks Copyright Power Gear Issued: January 2013 #82-L0524, Rev. OA Touch Pad LED Probable Cause Solution 1. On/Off LED will not light 2. Wait LED

More information

Expansion Unit Catalog Nos , - 152, - 153, - 154, - 156, -E157

Expansion Unit Catalog Nos , - 152, - 153, - 154, - 156, -E157 PRODUCT DA TA SLC 150 110 Expansion Unit Catalog Nos. 1745-151, - 152, - 153, - 154, - 156, -E157 7 : The EXpdnSiQn Unit The SLC 150 expansion unit can be used with either the SLC 150 processor unit or

More information

User Guide Automatic Transfer Switch (ATS)

User Guide Automatic Transfer Switch (ATS) User Guide Automatic Transfer Switch (ATS) V.1.0 Table of Contents 1. Introduction... 2 2. Product Overview... 2 3. Important Safety Warnings... 3 4. Operation Indicators & Status... 3 5. Installation...

More information

QUICK START GUIDE Paralleling and Protection Unit PPU 300

QUICK START GUIDE Paralleling and Protection Unit PPU 300 QUICK START GUIDE Paralleling and Protection Unit PPU 300 DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: +45 9614 9614 Fax: +45 9614 9615 info@deif.com www.deif.com Document no.: 4189341107B 1. Introduction

More information

OPERATION MANUAL CT-8 CONTAINER FILLING SYSTEM BY COUNT

OPERATION MANUAL CT-8 CONTAINER FILLING SYSTEM BY COUNT OPERATION MANUAL CT-8 CONTAINER FILLING SYSTEM BY COUNT ES-8004-CT8-MAN 2011 Congratulations, You have just purchased, and are about to use, one of MAC s many engineered quality products. When you buy

More information

SERIES CMT CARBON MONOXIDE GAS TRANSMITTER

SERIES CMT CARBON MONOXIDE GAS TRANSMITTER SERIES CMT CARBON MONOXIDE GAS TRANSMITTER INSTALLATION OPERATION AND MAINTENANCE MANUAL DWYER INTRUMENTS, INC. PO BOX 373, MICHIGAN CITY, IN. 46360 USA PHONE: 800-872-9141 FAX: 219-872-9057 Web: www.dwyer-inst.com

More information

Contents. Product name and model... 1 Specifications... 1 Appearance and Size... 1 Function Summary and Button Definition...2 Function Summary...

Contents. Product name and model... 1 Specifications... 1 Appearance and Size... 1 Function Summary and Button Definition...2 Function Summary... Contents Product name and model... 1 Specifications... 1 Appearance and Size... 1 Function Summary and Button Definition...2 Function Summary... 2 Button Definition...2 Assembly...2 Function Area Distribution...2

More information

Genset Controller Unit Model EMS - GC10. Installation Manual Section

Genset Controller Unit Model EMS - GC10. Installation Manual Section Genset Controller Unit Model EMS - GC10 Installation Manual 00-02-0794 Section 75 2013-01-28 In order to consistently bring you the highest quality, full featured products, we reserve the right to change

More information

Specifications N Termination Voltage Range Current Consumption, Max. Type Number Termination. Voltage Range. Sinking Sensor Current

Specifications N Termination Voltage Range Current Consumption, Max. Type Number Termination. Voltage Range. Sinking Sensor Current Description The N24 Controller is a specialized Motorized Roller Driver Module for NorthAmCon Mech-Rollers. It includes the following features: 6 PNP Auxiliary I/O points to provide enhanced diagnostic

More information

DUAL SWITCH CONTROLLER

DUAL SWITCH CONTROLLER DUAL SWITCH CONTROLLER INSTRUCTION MANUAL IMPORTANT: If the Dual Switch Controller is to be used with a Dielectric 50000 Series Switch, control cable P/N 1100007364 or 11000007365 must be used. See Section

More information

RS-232/422/485 to Copper or Fiber. Ethernet Converter. User s Manual

RS-232/422/485 to Copper or Fiber. Ethernet Converter. User s Manual RS-232/422/485 to Copper or Fiber Ethernet Converter User s Manual Table Of Contents TABLE OF CONTENTS... 1 INTRODUCTION... 3 PRODUCT OVERVIEW... 3 PRODUCT FEATURES... 3 PACKING LIST... 4 LED INDICATORS...

More information

Operating Manual. CS-5000 and CS-5100 Ultrasonic Controls. Coil Technology, Incorporated Wadsworth, Ohio 44281

Operating Manual. CS-5000 and CS-5100 Ultrasonic Controls. Coil Technology, Incorporated Wadsworth, Ohio 44281 coiltek Operating Manual CS-5000 and CS-5100 Ultrasonic Controls Coil Technology, Incorporated Wadsworth, Ohio 44281 Phone: 330-334-1525 Fax: 330-335-4406 Web: www.coiltek.com e-mail: info@coiltek.com

More information

VISTA 12a / 48a TECHNICAL TRAINING. The Best in Security plus Everyday Convenience & Control

VISTA 12a / 48a TECHNICAL TRAINING. The Best in Security plus Everyday Convenience & Control VISTA 12a / 48a TECHNICAL TRAINING The Best in Security plus Everyday Convenience & Control Version #.007 7th June 2005 VISTA 12a / 48a Training Guide Index 1. Vista Family Features....... p. 3 2. Wiring

More information

Installation and Operation Back-UPS Pro BR700G-TW

Installation and Operation Back-UPS Pro BR700G-TW Installation and Operation Back-UPS Pro BR700G-TW Inventory Safety Do not install the UPS in direct sunlight, in excessive heat, humidity, or in contact with fluids. Do not connect a laser printer or hair

More information

Digital Keypad Introduction

Digital Keypad  Introduction K2 Digital Keypad Introduction The K02 uses the latest microprocessor technology to operate door strikes and security systems that require a momentary (timed) or latching dry contact closure. All programming

More information

INTRODUCTION CT87E FEATURES AND CONTROLS

INTRODUCTION CT87E FEATURES AND CONTROLS INTRODUCTION The CT87E is a precision instrument used to monitor and record the presence or absence of voltage, light, or sound level such as what would be produced by an operating electric motor or compressor.

More information

Network Video Recorder Quick Operation Guide

Network Video Recorder Quick Operation Guide Network Video Recorder Quick Operation Guide UD.6L0202B1351A01 TABLE OF CONTENTS NVR Pre-Installation... 2 NVR Installation... 2 Hard Disk Installation... 2 Front Panels... 6 DS-9500NI-ST/RT Front Panel...

More information

Installation and Wiring

Installation and Wiring Wiring 2 2 Plan for Safety Safety Techniques WARNING: Providing a safe operating environment for personnel and equipment is your responsibility and should be your primary goal during system planning and

More information

Industrial Serial Device Server

Industrial Serial Device Server 1. Quick Start Guide This quick start guide describes how to install and use the Industrial Serial Device Server. Capable of operating at temperature extremes of -10 C to +60 C, this is the Serial Device

More information

Torque Control Verifier

Torque Control Verifier Torque Control Verifier Instruction Manual Revision 1.2 September 2002 Please Read and Understand Instructions Before Attempting Installation Torque Control Verifier Contents: Quick Start Introduction

More information

OPERATING INSTRUCTIONS. For the KNOPP TYPE KCTS-8000 CURRENT TRANSFORMER TESTING SYSTEM. Serial Number: Leaflet Number G.

OPERATING INSTRUCTIONS. For the KNOPP TYPE KCTS-8000 CURRENT TRANSFORMER TESTING SYSTEM. Serial Number: Leaflet Number G. OPERATING INSTRUCTIONS For the KNOPP TYPE KCTS-8000 CURRENT TRANSFORMER TESTING SYSTEM Serial Number: Leaflet Number 2 015 G October 2016 Knopp Incorporated 1307 66th Street Emeryville, California 94608

More information

DATRAN XL4 PLUS RTU Quick Start Guide

DATRAN XL4 PLUS RTU Quick Start Guide DOC-QSG-XL4-PLUS-RTU DATRAN XL4 PLUS RTU Quick Start Guide Configuring the XL4 Plus RTU The XL4 Plus RTU is configured using software called QTech Workbench. Connection to your PC is via a USB cable (Type

More information

RangerBOSS Network Ready Constant Monitor Model CM2800

RangerBOSS Network Ready Constant Monitor Model CM2800 RangerBOSS Network Ready Constant Monitor Model CM2800 Instruction Manual Contents 1 Description CM2800 1 Features 1 2 Installation Installation Instructions 2 Installation Diagram 3 3 Operation Wrist

More information

M-5072 Retrofit Kit For M-4272 Digital Motor Bus Transfer System

M-5072 Retrofit Kit For M-4272 Digital Motor Bus Transfer System SYNCHRONIZING M-5072 Retrofit Kit For M-4272 Digital Motor Bus Transfer System Adapts M-4272 Digital Motor Bus Transfer System as a replacement for existing analog motor bus transfer equipment Provides

More information

Revolutionizing control wiring

Revolutionizing control wiring SmartWire-DT Panel Wiring Solutions Revolutionizing control wiring 797-6925 Fax: (215) 221-1201 www.royalelectric.com SmartWire-DT Changing the way panels are wired. Reduce cost throughout the value chain.

More information

AirTest Model CN9000 Series Sensor Controller

AirTest Model CN9000 Series Sensor Controller AirTest Model CN9000 Series Sensor Controller AirTest Model CN9000 Series Sensor Controller THEORY OF OPERATION A basic CN9000 configuration consists of Input/Process/Display combination modules, a 3 relay

More information

Profinet Module. User Manual. Contents

Profinet Module. User Manual. Contents User Manual Contents 1 Important User Information... 2 2 Installation... 3 3 Connection... 4 4 Device Configuration... 5 5 Operation... 7 6 Packet Structures... 8 7 Network Design... 16 8 Specifications...

More information

Press the PEN HOME key to move the pen(s) to the outside of the chart. The pen(s) is automatically raised off the chart.

Press the PEN HOME key to move the pen(s) to the outside of the chart. The pen(s) is automatically raised off the chart. DICKSON GETTING STARTED 7-day chart rotation 0 to 100 o F KT8P0/2/3 & KT856 Remote Sensing Temperature Recorder QUICK START 1. Remove the protective pen cap(s). 2. Connect Probe(s): a. KT8P0/2/3: Make

More information

PHASETRONICS. SCR Power Control Specialists. EP1 Series Power Control Single Phase SCR Amps OPERATION & SERVICE MANUAL

PHASETRONICS. SCR Power Control Specialists. EP1 Series Power Control Single Phase SCR Amps OPERATION & SERVICE MANUAL PHASETRONICS Specialists EP1 Series Power Control Single Phase SCR 10-50 Amps OPERATION & SERVICE MANUAL Phasetronics, Inc. P.O. Box 5988 1600 Sunshine Drive Clearwater, FL 33765 (727)573-1900 FAX(727)573-1803

More information

Answers to Chapter 2 Review Questions. 2. To convert controller signals into external signals that are used to control the machine or process

Answers to Chapter 2 Review Questions. 2. To convert controller signals into external signals that are used to control the machine or process Answers to Chapter 2 Review Questions 1. To accept signals from the machine or process devices and to convert them into signals that can be used by the controller 2. To convert controller signals into

More information

Allen-Bradley Drives

Allen-Bradley Drives Installation Data This document provides information on: important pre installation considerations power supply requirements installing the module installing and connecting the wiring using the module

More information

Compact Genset Controller, CGC 400 What's in the delivery? The first steps Push-buttons and LEDs

Compact Genset Controller, CGC 400 What's in the delivery? The first steps Push-buttons and LEDs QUICK START GUIDE Compact Genset Controller, CGC 400 What's in the delivery? The first steps Push-buttons and LEDs DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: +45 9614 9614 Fax: +45 9614 9615 info@deif.com

More information

ZC Series Zone Monitoring Controllers

ZC Series Zone Monitoring Controllers ZC Series Zone Monitoring Controllers Installation Instructions MANUAL Reset Controllers Model Description Part Number ZC-1 1 Zone Controller 0421 ZC-2 2 Zone Controller 0422 ZC-3 3 Zone Controller 0423

More information

INSTALLATION AND OPERATING INSTRUCTIONS DSST SYSTEM

INSTALLATION AND OPERATING INSTRUCTIONS DSST SYSTEM INSTALLATION AND OPERATING INSTRUCTIONS DSST SYSTEM PROPORTIONAL and NON-PROPORTIONAL TOGGLE SWITCH RADIO REMOTE CONTROL SYSTEM MODEL FHSTP/DSSTP SERIES FHST/DSST SYSTEM DESCRIPTION The DSST Wireless Control

More information

M15S OPERATION MANUAL

M15S OPERATION MANUAL M15S OPERATION MANUAL minikol ITALY www.minikol.com Index 1. Operation overview and general introduction... 1 2. Operation Modes... 2 2.1. Manual mode...2 2.2. Single mode...3 2.2.1. Setting target value...3

More information

MOTION LABORATORIES CHAIN HOIST MOTOR CONTROL SYSTEMS MANUAL. Basic Outline of Operation for Distro Controllers

MOTION LABORATORIES CHAIN HOIST MOTOR CONTROL SYSTEMS MANUAL. Basic Outline of Operation for Distro Controllers MOTION LABORATORIES CHAIN HOIST MOTOR CONTROL SYSTEMS MANUAL Forward The main body of text in this manual concerns four through eight channel portable chain hoist motor control systems with 208-230 VAC

More information

Research Concepts RC2500 Antenna Interface Unit (AIU) Board Set

Research Concepts RC2500 Antenna Interface Unit (AIU) Board Set Research Concepts RC2500 Antenna Interface Unit (AIU) Board Set A board set has been developed that can be incorporated into an AIU for an RC2500 antenna controller. This board set is the basis of RC2500

More information

Master-Touch INSTRUCTION MANUAL. Series 9000MP Multipoint System Series 9600MP System Control Panel Thermal Gas Mass Flowmeters. version 7.

Master-Touch INSTRUCTION MANUAL. Series 9000MP Multipoint System Series 9600MP System Control Panel Thermal Gas Mass Flowmeters. version 7. Master-Touch version 7.x firmware Series 9000MP Multipoint System Series 9600MP System Control Panel Thermal Gas Mass Flowmeters INSTRUCTION MANUAL 80201501 Addendum Rev. C www.epiflow.com Eldridge Products,

More information

DC3IOB Revision User Guide Updated 3/29/10. Overview

DC3IOB Revision User Guide Updated 3/29/10. Overview Revision 080910 User Guide Updated 3/29/10 Overview The is a three axis DC brush motor drive with an integrated PLC. A range of motor drive currents are selectable with jumper blocks. The integrated PLC

More information

BA/BS4S Temperature Sensor Installation & Operating Instructions

BA/BS4S Temperature Sensor Installation & Operating Instructions Product Overview and Identification The BAPI-Stat 4 room temperature sensor features a large format LCD and slider setpoint adjustment. Additional options include button override and communication jack.

More information

GV3000/SE Operator Interface Module (OIM) User Guide Version 2.0 M/N 2RK3000

GV3000/SE Operator Interface Module (OIM) User Guide Version 2.0 M/N 2RK3000 GV3000/SE Operator Interface Module (OIM) User Guide Version 2.0 M/N 2RK3000 Instruction Manual D2-3342-2 The information in this manual is subject to change without notice. Throughout this manual, the

More information

Manual Control Unit GFC 32

Manual Control Unit GFC 32 Manual Control Unit 1400004_EN/05.2017 Index 1. Main features 3 2. Technical features 3 3. Installation guidelines 4 4. Preliminary checks 5 5. Electrical connections 5 6. Settings 6 7. Remote control

More information

MT8050iE series. Installation Instruction (1) (2)

MT8050iE series. Installation Instruction (1) (2) MT8050iE series 3 Installation Instructions Installation Instruction Secure the operator panel in position, using all the fastening holes and the provided brackets and screws: (A) 1 Installation and Startup

More information

Table of Contents. Unpacking and Inspection Setup Loading the Media Mount the Printer on the Wall... 16

Table of Contents. Unpacking and Inspection Setup Loading the Media Mount the Printer on the Wall... 16 WPL25/WHC25 Table of Contents Unpacking and Inspection... 1 Setup... 5 Loading the Media... 6 Mount the Printer on the Wall... 16 LED and Button Functions... 17 Troubleshooting... 18 Unpacking and Inspection

More information

output devices. connected to the controller. data communications link. relay systems. user program. MECH1500Quiz1ReviewVersion2 Name: Class: Date:

output devices. connected to the controller. data communications link. relay systems. user program. MECH1500Quiz1ReviewVersion2 Name: Class: Date: Class: Date: MECH1500Quiz1ReviewVersion2 True/False Indicate whether the statement is true or false. 1. The number and type of I/Os cannot be changed in a fixed PLC. 2. In a PLC system, there is a physical

More information

MULTISPENSE 900 W/TOUCHSCREEN CONTROLLER MODULE Page 3-1. Table Of Contents. Section Description Page #

MULTISPENSE 900 W/TOUCHSCREEN CONTROLLER MODULE Page 3-1. Table Of Contents. Section Description Page # MULTISPENSE 900 W/TOUCHSCREEN CONTROLLER MODULE Page 3-1 Table Of Contents Section Description Page # 3. Multispense 900 W/Touchscreen Controller Module... 3-2 3.1 Description... 3-2 3.1.1 Front Panel

More information

FG-7000 Digital Force Gauge Operation Manual

FG-7000 Digital Force Gauge Operation Manual FG-7000 Digital Force Gauge Operation Manual Operators should wear protection such as a mask and gloves in case pieces or components break away from the unit under test. Whether the unit is ON or OFF,

More information

5.1. Motor Protection and Monitoring. Contents. Product Overview. Monitoring Relays. D64R Series Digital Ground Fault Relays...

5.1. Motor Protection and Monitoring. Contents. Product Overview. Monitoring Relays. D64R Series Digital Ground Fault Relays... .1 Ground Fault Relays and Monitors Contents Description Current.................. Phase................... Voltage.................. Ground Fault Relays and Monitors D64R Series Digital Ground Fault Relays....

More information

DEEP SEA ELECTRONICS PLC

DEEP SEA ELECTRONICS PLC COMPLEX SOLUTIONS MADE SIMPLE. DEEP SEA ELECTRONICS PLC DSE5320 AUTO MAINS FAILURE MODULE OPERATING MANUAL http://bestgenerator.spb.ru/?page_id=6765 Deep Sea Electronics Plc Highfield House Hunmanby North

More information

Ethernet/IP Module. User Manual. Contents

Ethernet/IP Module. User Manual. Contents User Manual Contents 1 Important User Information... 2 2 Installation... 3 3 Connection... 4 4 Device Configuration... 5 5 Operation... 8 6 Packet Structures... 9 7 Network Design... 18 8 Specifications...

More information

TABLE OF CONTENTS 1. OVERVIEW SPECIFICATIONS UNPACKING & INSTALLATION FUNCTION OVERVIEW FUNCTION OVERVIEW...

TABLE OF CONTENTS 1. OVERVIEW SPECIFICATIONS UNPACKING & INSTALLATION FUNCTION OVERVIEW FUNCTION OVERVIEW... TABLE OF CONTENTS 1. OVERVIEW... 3 2. SPECIFICATIONS... 3 2.1 ELECTRICAL...3 2.2 MECHANICAL...4 2.3 VARIABLES AND THEIR LIMITS...4 3. UNPACKING & INSTALLATION... 5 3.1 UNPACKING THE UNIT...5 3.2 MOUNTING

More information

Hardened Web-Smart PoE & High Power PoE Ethernet Switch

Hardened Web-Smart PoE & High Power PoE Ethernet Switch Quick Start Guide This quick start guide describes how to install and use the Hardened Web-Smart PoE (Power over Ethernet) and High Power PoE Ethernet Switch. This is the switch of choice for harsh environments

More information

IS-S0108 Single Switch Solution

IS-S0108 Single Switch Solution IS-S0108 Single Switch Solution IS-S0108 Single Switch Solution Revision D NKK SWITCHES 7850 E. Gelding Drive Scottsdale, AZ 85260 Toll Free 1-877-2BUYNKK (877-228-9655) Phone 480-991-0942 Fax 480-998-1435

More information

Instruction Manual. M Pump Motor Controller. For file reference, please record the following data:

Instruction Manual. M Pump Motor Controller. For file reference, please record the following data: Instruction Manual M Pump Motor Controller For file reference, please record the following data: Model No: Serial No: Installation Date: Installation Location: When ordering replacement parts for your

More information

PLC. Module 3: Hardware and Terminology. IAT Curriculum Unit PREPARED BY. Jan 2010

PLC. Module 3: Hardware and Terminology. IAT Curriculum Unit PREPARED BY. Jan 2010 PLC Module 3: Hardware and Terminology PREPARED BY IAT Curriculum Unit Jan 2010 Institute of Applied Technology, 2010 ATE321 PLC Module 3: Hardware and Terminology Module Objectives Upon successful completion

More information

COMMONLY USED 5.AFETY SENSORS. Photocell (Reflector) CLOSING Direction. Photocell (Reflector) CLOSING Direction OA4RO E.3IC-RIOIC4 EA4X IRB-RET

COMMONLY USED 5.AFETY SENSORS. Photocell (Reflector) CLOSING Direction. Photocell (Reflector) CLOSING Direction OA4RO E.3IC-RIOIC4 EA4X IRB-RET MLY USED 5.AFETY SENSORS 0----- OA4RO E.IC-RIOIC4 Direction. Set switch to "LIGHT ". Wire V power to photocell. Wire to photocell N0 Wire to photocell C- 4. Align photocell to reflector 5. Adjust sensitivity

More information

Series F75 Fail-Safe Module Installation, Operation and Maintenance Instructions

Series F75 Fail-Safe Module Installation, Operation and Maintenance Instructions WCAIM2029 (Part 16022) Series F75 Fail-Safe Module Installation, Operation and Maintenance Instructions CAUTION: Flowserve recommends that all products that must be stored prior to installation be stored

More information

TOSLINE-S20 Active Star Coupler Instruction Manual

TOSLINE-S20 Active Star Coupler Instruction Manual TOSLINE - S20 Active Star Coupler Instruction Manual September, 1995 Toshiba International Corporation UM-TLS20**-E004 Table of Contents 1. Introduction... 2 2. Overview... 3 3. Specifications... 4 3.1

More information

Operation Manual MODEL 2TX. 2-wire Isolated ph/orp Transmitter

Operation Manual MODEL 2TX. 2-wire Isolated ph/orp Transmitter Operation Manual MODEL 2TX 2-wire Isolated ph/orp Transmitter 0 2TX CONTENTS INITIAL INSPECTION.....2 INTRODUCTION......2 ASSEMBLY...3 PREPARATION....4 CONNECTING THE ELECTRODE...4 CONNECTING THE TEMPERATURE

More information

METERING/DISPLAY MANUAL

METERING/DISPLAY MANUAL METERING/DISPLAY MANUAL 175W - 750W SINGLE PHASE Series LV EMERGENCY LIGHTING CENTRAL INVERTER Myers Power Products, Inc. 44 South Commerce Way, Bethlehem, PA 18017 1-800-526-5088 (610) 868-3500 Fax: (610)

More information