1 DPS Telecom Your Partners in Telecom Management Networks Operation Guide LR24 Relay Card Table of Contents Overview...1 Table of Contents...1 Typical Relay Applications...2 Shipping List....2 Installation...2 Local Display...3 Fuse & Indicators....3 Configuration Software...3 Edit Expansion Ports...3 Hardware Connections...5 Output Diagrams...6 T/MonXM Programming...6 Test Procedure...6 Specifications...7 Options and Model Numbers...7 Overview DPS s LR24 Relay Card is a plug-in expansion card that fits in the KDA 864 Remote Telemetry Unit. The LR24 Relay Card gives the KDA the ability to operate an additional 24 Control Points with latching relay contacts. Addition of the LR24 Relay Card to the KDA gives it a total of 32 Control Points. Fig.1-LR24Relay Card fits in KDA Expansion Slot Downloadable Configuration The Relay Card can be configured for point description and latching or momentary operation. All configuration data for the LR24 Relay Card is entered via the same downloading software used to program the host KDA. Downloading can be done locally at the KDA s front panel connector or remotely via a dial-up modem. Configuration data is held in non-volatile memory to survive loss-of-power. Magnetic-Latching Relays Because they are magnetic-latching, the relays maintain their positions upon loss of power. A second set of contacts on each relay is used to report position to the front panel LEDs and back to the host T/MonXM or IAM, giving a true indication of operation. Relay position is reported as alarm status points 1-24, respectively on the same address and display assigned to the LR-24 control points. Connectorized Rear Panel The KDA is available in a connectorized model to simplify and speed installation. Connectorized KDA s can be ordered with a 50 pin Amphenol connector installed for the LR24 Relay Card. A connectorized version can also be ordered with a universal expansion card panel consisting of 8 DB9 connectors the will interface all currently available expansion cards. (See the KDA manual for ordering information.) Connectorization is a factory upgrade only. KDA Smarts Since the relay card is an expansion card for the KDA, it inherits all of the powerful features of the host KDA. For example, if the KDA is set to have alternate path, (dial up modem in case of dedicated path failure), then the relay card will have the same capabilities. NOTE: Since the Relay Card communicates through the KDA, the relay status will be reported to the interrogating master using the same protocol as the KDA. Software Version Notice The relay card requires T/KDA version 2.1 or later for configuration. T/MonXM software version 2.2f or later is required to operate the relays. D-PC A-00 1 OG-LR24-010

2 T/MonXM FA MODE A B Local and Remote Monitoring The same program and computer used for configuration may also be used for local monitoring and operation of the control points, allowing on-site testing of all relays. Remote monitoring and operation may likewise be performed via dial-up access. T/Mon Compatibility The relay card is compatible with T/MonXM WorkStation alarm master or the IAM (Intelligent Alarm Mediator). The software in these high level master stations allows you to: 1. Operate Control Points manually, 2. Send derived control commands based on alarms present, 3. Maintain point operation history, 4. Have multiple users access the system. Typical Relay Applications The relay outputs are A form (Normally Open) contacts. Any device that can be activated by a contact closure Fig. 3 shows a typical relay application to T/MonXM via dedicated line with dial back up. Shipping List Verify that the following were included with the Relay Card: LR24 Relay Card Operation Guide (This Manual) Spare Fuse Registration Card* T/KDA Software* *Normally the relay card is shipped installed in the host KDA. These items are then included with the = Installation Unpack the Relay Card. Fill out and mail the pre-posted registration card. LR24 RELAY CARD DPS INC. Mount Host KDA. See NOTE 1. Connect relay outputs, fuse alarm, power and LAN lines at back of KDA host per Hardware Connections section in this Operation Guide. See NOTE 2. Remove fuse from relay card before plugging in card. If the Relay Card is not already plugged into the KDA host, do so at this time. Install fuse after plugging in card. FA MODE A B Fig.2-LR24Operates a Variety of Devices can be controlled by the LR24. (See contact ratings under Specifications.) Fig. 2 shows a number of the possible devices that can be controlled by the relay card. KDA 864 DPS INC. DPS INC. Perform KDA checkout and software configuration. When configuring the KDA in the Edit Expansion Ports screen, enter the parameters for the relay card per the instructions in the Edit Expansion Ports section of this Operation Guide. Test the KDA per the KDA Manual. Test the Relay Card per the Test Procedure section of this Operation Guide. NOTE 1: If the Relay Card is shipped as part of the Host KDA the fuse alarm, power and LAN lines will be installed at the factory. The relay card will be plugged into the expansion slot on the host KDA and the entire unit will be tested at the factory. T/KDA LR24 RELAY CARD DPS INC. 24 ADDITIONAL CONTROL OUTPUTS VIAJ3ONBACKOFKDA Fig. 3 - Alternate Path Application NOTE 2: If a relay card is being added to a connectorized KDA that is not equipped with either the 50 pin Amphenol connector (J16) or the universal expansion card panel (8 DB9 connectors), the chassis will have to be returned to the factory for upgrading. Contact DPS customer support to make arrangements. 2 D-PC A-00

3 Local Display LR24 RELAY CARD The relay card comes with 8 LED s on the front panel. these show the status of all relays as indicated in the Display Function Table. The LED s automatically step through the points on a rotational basis. Display Function Table Label Display Function A Green LEDs 1-6 show relays 1-6. A Red LEDs 1-6 show relays B Green LEDs 1-6 show relays B Red LEDs 1-6 show relays Off Relay not operated. 1-6 Red Relay Operated. FA Off Fuse OK FA Red Fuse Blown Button Mode Fuse & Indicators FA MODE A B Fig.4-LR24Front Panel Button Function Table Function The Mode button has no function on the current version of the Relay Card. The front panel contains an easily accessible fuse. This fuse is independent of the fuse on the main KDA unit. The relay card has two different ways of reporting a blown fuse. The first is a red LED on the front panel which turns on KDA-J2 KDA-J3 X DPS INC. when the fuse is blown to allow the local personnel to quickly isolate the unit. The second method of notification is relay contact closure that can be wired into a local alarm device to notify on site personnel that the fuse is blown. NOTE:It is recommended that the expansion card fuse alarm be paralleled to the host KDA s fuse alarm. If either fuse fails, the local alarm will sound. The polling master will generate a communications failure alarm when the host or the expansion card fail to respond to polling. Refer to the connector pin layout drawings and tables for the fuse alarm output pin numbers. Fig. 5 shows how the fuse alarm is wired to the KDA. On a connectorized KDA the wiring is factory installed. Configuration Software The relay card is configured using T/KDA, which is a non-copy protected software that is supplied with each KDA or Relay card. This software is DOS based and can be used to create, maintain, download and upload provisioning data along with monitoring and controlling relay status. The configuration downloaded to the relay card is stored in non volatile memory (nvram) so the information will not be lost in the case of a power outage. T/KDA version 2.0d or later is required to support the LR24 Relay Card. NOTE 3: If the relay card is being added to an existing KDA with T/KDA software earlier than version 2.0d, contact DPS customer support to arrange a firmware upgrade for the KDA. It may be necessary to return the KDA board to the factory for the upgrade. Edit Expansion Ports Overall directions for the use of T/KDA software are found in the KDA manual. Follow those directions with the exception of the Edit Expansion Ports section. Use the following directions to define the expansion port for the relay card: The Edit Expansion Ports option is used when the KDA Expansion Slot is equipped with a TBOS, Analog or Relay Card. Satellite KDA s may not be equipped with an expansion card at the present time. The current version of T/KDA supports both the 4 and 8 Port TBOS cards as well as the analog and relay card. Important: All configuration data must be saved by using the F8 key in order for them to become effective. Using the F10 key will exit without saving. X Fig. 5 - Fuse Alarm Wiring D-PC A-00 3 OG-LR24-010

4 Type Card Hot Keys in the Edit Relay Expansion Port Screen Key Description F3 Blank. Leaves this line without an entry F5 Edit Momentary Period (See below) F8 Save F9 Help F10/Esc Exit Momentary Period Fig. 6 - Select LR 24 The first screen after selecting Edit Expansion Ports asks for the type card. Refer to Fig. 6. Use the Tab key to highlight the type card (LR-24) installed in the KDA and <ENTER> to select it. The next screen requires information to be entered for each relay. Description Field Refer to Fig. 7. The cursor will move to the Exp Add 1 field. Enter address from 0 to 255. Press Enter. The cursor will move to the description field for relay 1. Fill in a description and press Enter. The cursor will move to the description field for relay 2. Continue to fill in descriptions for each relay. When completed, the list can be saved by pressing F8. Edit Relay Expansion Port Screen Field Expansion Type Exp Add Description Fig. 7 - Enter Point Descriptions Description Use tab key to select LR-24. Enter address. In the past this has been the host KDA address plus one, but in T/KDA version 2.1 and later ith expansion card address can be totally independent of the base address. NOTE: Use address 0 if the card is not to respond to the polling master at this time. This will allow it to be tested locally. Enter the point description, up to 13 characters. NOTE 4: The description remains in the T/KDA data base for use in Monitor Mode. It is not downloaded to the KDA. Fig. 8 - Set LR 24 Momentary Periods Fress F5 while in the Relay Description screen. Refer to Fig. 8. Momentary time periods can be assigned in four groups, relays 1-6, 7-12, and Time may be between 0.1 and 25.5 seconds, in 0.1 sec increments. NOTE 5: Momentary periods are used when a momentary command is issued to a relay. When a latching command is sent, the momentary period is ignored. Each relay can function as momentary or latching, depending on the command sent. When all relays have been defined exit the Edit Expansion Ports mode by using F8 to save. To exit this mode without saving use F10. Follow the KDA manual directions to download the configurations to the Relay Card. Monitor Mode Fig. 9 - View Relay Status in Monitor Mode The status of the alarm and control points on the KDA can be observed with T/KDA by selecting the monitor mode under Connect Direct or Connect Modem from the main T/KDA menu. The monitor screen will come up, showing 4 D-PC A-00

5 the status of alarm points and the 8 standard control points on the main KDA unit. To see the status of the control points on the LR 24 Relay Card, press F6. The screen is illustrated in Fig. 9. R indicates a released status; L indicates a latched status.the relay descriptions will appear on the line next to the satus of each relay. Hot Keys Available in the Monitor Relay Screen Key F1 F2 F3 F4 F10/Esc Hardware Connections Description Operate relay Release relay Operate relay momentarily Displays protocol analyzer at bottom of screen. Exit the Monitor Relay screen and return to the Alarm Status Screen. J3 J1 J2 D-PC A-XX LR 24 RELAY CARD REAR PANEL CONNECTOR J3 Pin Layout (on Rear of KDA) PIN # DESCRIPTION PIN # DESCRIPTION RLY 1 NORM OPEN RLY 2 NORM OPEN RLY 3 NORM OPEN RLY 4 NORM OPEN RLY 5 NORM OPEN RLY 6 NORM OPEN RLY 7 NORM OPEN RLY 8 NORM OPEN RLY 9 NORM OPEN RLY 10 NORM OPEN RLY 11 NORM OPEN RLY 12 NORM OPEN RLY 13 NORM OPEN RLY 14 NORM OPEN RLY 15 NORM OPEN RLY 16 NORM OPEN RLY 17 NORM OPEN RLY 18 NORM OPEN RLY 19 NORM OPEN RLY 20 NORM OPEN RLY 21 NORM OPEN RLY 22 NORM OPEN RLY 23 NORM OPEN RLY 24 NORM OPEN LAN TX LAN AC FUSE ALARM -BATT RLY 1 COMM RLY 2 COMM RLY 3 COMM RLY 4 COMM RLY 5 COMM RLY 6 COMM RLY 7 COMM RLY 8 COMM RLY 9 COMM RLY 10 COMM RLY 11 COMM RLY 12 COMM RLY 13 COMM RLY 14 COMM RLY 15 COMM RLY 16 COMM RLY 17 COMM RLY 18 COMM RLY 19 COMM RLY 20 COMM RLY 21 COMM RLY 22 COMM RLY 23 COMM RLY 24 COMM LREQ LAN RX FUSE ALARM GND Fig Wire-Wrap Pins on Rear of Standard KDA Standard (non-connectorized) KDA All connections to the relay card are made at wire-wrap connector J3 on the back of the KDA chassis (see Fig. 12 on p. 5 for pin-outs). Power must be independently wired to J3 - it is not supplied from the KDA. NOTE 6: If the host KDA was equipped with the LR24 at the factory, the power connections will already be made. The communications LAN must be jumpered from J2 to J3 per the table below. (See Fig.11) NOTE 7: If the host KDA was equipped with the LR24 at the factory, the LAN connections will already be made. LAN Connections From To J2-36 J3-51 J2-43 J3-52 J2-44 J3-49 Fig Non-Connectorized LR 24 Wiring Relay Card J3 KDA J2 Fig LAN wiring on Non-Connectorized KDA D-PC A-00 5 OG-LR24-010

6 J17 J16 -BATT GND CHASSIS GND Fig Pin Amphenol Connector on Rear of Connectorized KDA Connectorized KDA All connections to the relay card are made at 50-pin Amphenol connector J16 on the back of the chassis (see Fig. 13) or to the 8 DB9 connectors on the universal expansion card panel (see Fig. 14). The pin-outs are listed in the tables that follow. NOTE 8: The expansion card fuse alarm, LAN and power connections are made internally at the factory. J16 50 PIN AMPHENOL to LR-24 Relay Card Pin No. Function Pin No. Function 1 RLY 1 COM 26 RLY 1 N.O. 2 RLY 2 COM 27 RLY 2 N.O. 3 RLY 3 COM 28 RLY 3 N.O. 4 RLY 4 COM 29 RLY 4 N.O. 5 RLY 5 COM 30 RLY 5 N.O. 6 RLY 6 COM 31 RLY 6 N.O. 7 RLY 7 COM 32 RLY 7 N.O. 8 RLY 8 COM 33 RLY 8 N.O. 9 RLY 9 COM 34 RLY 9 N.O. 10 RLY 10 COM 35 RLY 10 N.O. 11 RLY 11 COM 36 RLY 11 N.O. 12 RLY 12 COM 37 RLY 12 N.O. 13 RLY 13 COM 38 RLY 13 N.O. 14 RLY 14 COM 39 RLY 14 N.O. 15 RLY 15 COM 40 RLY 15 N.O. 16 RLY 16 COM 41 RLY 16 N.O. 17 RLY 17 COM 42 RLY 17 N.O. 18 RLY 18 COM 43 RLY 18 N.O. 19 RLY 19 COM 44 RLY 19 N.O. 20 RLY 20 COM 45 RLY 20 N.O. 21 RLY 21 COM 46 RLY 21 N.O. 22 RLY 22 COM 47 RLY 22 N.O. 23 RLY 23 COM 48 RLY 23 N.O. 24 RLY 24 COM 49 RLY 24 N.O. 25 FUSE ALM 50 FUSE ALM Fig Universal Expansion Card Panel Expansion Card Universal Panel Connector Pin-outs Connector Pin No. J3 (on Main KDA) LR-24Relay Card J1 1 3 Relay Relay Relay Relay Relay Relay 17 J2 1 7 Relay Relay Relay Relay Relay Relay 18 J Relay Relay Relay Relay Relay Relay 19 J Relay Relay Relay Relay Relay Relay 20 J Relay Relay Relay Relay Relay Relay 21 J Relay Relay Relay Relay Relay Relay 22 6 D-PC A-00

7 Connector Pin No. J3 (on Main KDA) LR-24Relay Card J Relay Relay Relay Relay Relay Relay 23 J Relay Relay Relay Relay Relay Relay 24 points are not defined, control point operation will be reported as undefined alarms. Dial Up KDA Mapping When a relay card is reporting through a host KDA dial-up channel (whether primary or backup) it is defined in the dial-up Networks Menu as a KDA site. The steps for naming the alarm points and specifying parameters will be found under the Dial Up Remotes instructions in the T/MonXM manual. For all other parameters a screen like the one for DCPF will appear. Refer to the Standard Dial Up Remotes Module Section in the T/MonXM Manual. Follow the procedure for defining a KDA as a Dial Up Remote. Fuse Alarm The fuse alarm relay contacts can be wired into a local alarm device to notify on site personnel that the fuse is blown. NOTE:It is recommended that the expansion card fuse alarm be paralleled to the host KDA s fuse alarm. If either host fuse fails, the local alarm will sound. The polling master will generate a communications failure alarm when the host or the expansion card fail to respond. Refer to the connector pin layout drawings and tables for the fuse alarm output pin numbers. Fig. 5 shows how the fuse alarm is wired to the KDA. On a connectorized KDA the wiring is factory installed. Output Diagrams Fig Typical Relay Contact Schematic The illustration in Fig. 15 shows a typical relay output schematic. T/MonXM Programming The Relay Card communicates through the KDA to the interrogating master using the same protocol as the KDA. Dedicated DCPF Alarm Mapping The relay card is defined in T/MonXM just like any other alarm reporting device, with the following specific instructions: 1. The DCPF address may be any available address (T/KDA version 2.1 or later. With previous versions it must be the address of the host KDA plus one.) 2. The relay card uses display 1 of that address. 3. Points 1-24 of the display are used. 4. Control point operation is reported as alarm status points 1-24 of the selected address and display. If these Fig Define LR24 Virtual Address in the Device Definition Screen The LR24 is defined as a seperate device from the host KDA. In the Device Definition Screen type F for a new device and enter the device number in the Name or Number field. This number must match the number defined for the host KDA. Press <Enter>. A KDA Unit Type selection box will appear. Use the Tab key to highlight LR-24 and press <Enter>. The prompt line at the bottom of the screen will ask if it is to be added. Press Y. The rest of the screen like that shown in Fig. 16 will be displayed. Fill in the rest of the fields per the T/MonXM Manual. The virtual address does have to be unique among all other dial up device virtual addresses. (It cannot even be the same as the base or host KDA). In the example shown in Fig. 16 the virtual address chosen is 3. Fig Define RP Channel and Virtual Address in Control Point Definition Screen D-PC A-00 7 OG-LR24-010

8 Make note of the virtual address and complete device definition as for any KDA. The status of control points 1-24 is reported as alarm status points 1-24, respectively, of the same virtual address. Press F1 to enter descriptions and other data for the status report. Archiving and other features of alarm reporting will be valid, if defined. Otherwise, control point operation will generate undefined alarms. Refer to the File Maintenance Section in the T/MonXM Manual. The control points on the LR24 can be defined as site controls, labeled controls or both. In the Control Point Definition Screen for either type of control, the channel (Ch) field must be RP and the address (Add) must be the virtual address. In the example shown in Fig. 17 the channel entry is RP and the virtual address entry is 3, the same as that shown in Fig. 16. Enter all other fields per the instructions in the T/MonXM Manual. Points 1-24 are valid. Test Procedure After completing installation of the relay card in a KDA host test the unit as follows: 1. Exercise all relays. Use a meter or other indicator to verify continuity between the closed relay contacts. 2. Observe the LED indicators on the front panel display. Options and Model Numbers D-PC A-XV LR24 Relay Card -XV Option Numbers: Firmware Option (X): 1 Standard 5 Extended Temperature Range Power Supply Voltage*(V):2 Negative 24 VDC 3 Positive 24 VDC 4 Negative 48 VDC *Power option must match the host KDA s power option. Other KDA Expansion Cards: D-PC A-00 D-PC A-00 D-PC A-00 8 Channel Analog Card 4 Port TBOS Scanner 8 Port TBOS Scanner Specifications Number of Relay outputs: 24 Power Input: -24 VDC Unit: -18 to -36 VDC. 20 VDC. +24 VDC Unit: +18 to +36 VDC. 20 VDC. -48 VDC Unit: -36 to -72 VDC VDC. Fuse: 1/4 Amp Operating Range: 0 to +60 Degrees Celsius. Option X5-30 to +70 Degrees Celsius. Humidity: 0% to 95% non-condensing. Relay Contacts: Initial Contact Resistance...50 milleohms Contact Material Gold-Clad Silver Max. Switching Power 60 W, 125 VA Max. Switching Voltage: VDC, 250 VAC Max. Switching Current:...2A Max. Carrying Current: 3A Electrical Life 30 VDC): 500,000 Operations. DPS Telecom Your Partners in Telecom Management Networks 4955 E. Yale - Fresno, CA Phone (559) / (800) FAX (559) Visit our Web site at dpstele.com - sales@dpstele.com 8 D-PC A-00

DPS INC ASCII MUX. Operation Guide. Table Of Contents. Overview. T/kda

DPS INC ASCII MUX. Operation Guide. Table Of Contents. Overview. T/kda DPS INC Operation Guide "Your Partners in Telemetry Monitoring Systems" ASCII MUX Fig. - ASCII MUX Expands T/MonXM ASCII s up to Eight Times Table Of Contents Overview... Functional Schematic... Typical

More information

DPS INC. TL1 4-Port MUX. Operation Guide TABLE OF CONTENTS. Overview

DPS INC. TL1 4-Port MUX. Operation Guide TABLE OF CONTENTS. Overview DPS INC "Your Partners in Telemetry Monitoring Systems" TABLE OF CONTENTS Overview.... Functional Schematic... Typical MUX Applications... Shipping List... Installation... and SWT Buttons... LED Display

More information

Alarm Distribution Shelf (ADS)

Alarm Distribution Shelf (ADS) DPS Telecom Operation Guide "Your Partners In Telecom Management Networks" Alarm Distribution Shelf (ADS) Overview The ADS permits building and facility owners to collect and distribute alarms to their

More information

KDA 864-TL1. Version 2.1b User s Manual. DPS Telecom. "Your Partners in Network Alarm Management"

KDA 864-TL1. Version 2.1b User s Manual. DPS Telecom. Your Partners in Network Alarm Management KDA 864-TL1 Version 2.1b User s Manual DPS Telecom "Your Partners in Network Alarm Management" 4955 East Yale Avenue Fresno, CA 93727 Tel: (559) 454-1600 - Fax: (559) 454-1688 e-mail: sales@dpstelecom.com

More information

KDA 864 Version 2.1i through 2.1q User s Manual UM DPS Telecom

KDA 864 Version 2.1i through 2.1q User s Manual UM DPS Telecom KDA 864 Version 2.1i through 2.1q User s Manual UM113739 DPS Telecom 4955 East Yale Avenue Fresno, CA 93727 Tel: (559) 454-1600 - Fax: (559) 454-1688 E-mail: sales@dpstele.com Visit our Web Site at http://www.dpstele.com

More information

B Polling Interface

B Polling Interface Your Partners in Network Alarm Management 232-485B Polling Interface USER MANUAL Visit our website at www.dpstelecom.com for the latest PDF manual and FAQs. July 31, 2006 D-OC-UM067.31100 Firmware Version

More information

INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx

INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual PCMNET V 7. xx INTEGRATED SYSTEMS AND CONTROLS, INC. PCMNET Users Manual Revised 2/4/2005 2003-2005 Integrated Systems and Control. Inc. PO Box

More information

General LCD Display (GLD)

General LCD Display (GLD) DPS Telecom Your Partners in Network Alarm Monitoring General LCD Display (GLD) USER MANUAL Visit our website at www.dpstelecom.com for the latest PDF manual and FAQs. June 2, 2010 D-OC-UM106.02100 Version

More information

DKG-210 UNIVERSAL INTERNET GATEWAY UNIT

DKG-210 UNIVERSAL INTERNET GATEWAY UNIT DKG-210 UNIVERSAL INTERNET GATEWAY UNIT AC & DC SUPPLY VERSIONS DESCRIPTION The DKG-210 is designed for internet monitoring and control of industrial devices using different protocols through the RAINBOW

More information

Digital Keypad Introduction

Digital Keypad  Introduction K2 Digital Keypad Introduction The K02 uses the latest microprocessor technology to operate door strikes and security systems that require a momentary (timed) or latching dry contact closure. All programming

More information

Innovative Electronics for a Changing World INDEX

Innovative Electronics for a Changing World INDEX Innovative Electronics for a Changing World INDEX 1. SYSTEM DESCRIPTION 2. BOARD CONNECTIONS terminals and indicators 3. CONNECTION DIAGRAM 4. START UP GUIDE and passwords 5. HOME PAGE 6. STATUS PAGE 7.

More information

Universal Expander Module INSTALLATION MANUAL. Overview. Electrical Specifications

Universal Expander Module INSTALLATION MANUAL. Overview. Electrical Specifications 12 Universal Expander Module. Installation Notes. Revision 1.2 August. 2003. 1 Reporting Reporting with most Contact ID maps will treat the Mini Expander, Exp32 and Exp16 as the same. (With the exception

More information

Model 305e OEM CO 2 concentration sensor

Model 305e OEM CO 2 concentration sensor Model 305e OEM CO 2 concentration sensor preliminary Reference manual DIGITAL CONTROL SYSTEMS 7401 SW Capitol Hwy. Portland, OR 97219 USA 503/246-8110 503/246-6747 (fax) www.dcs-inc.net Scope...3 Introduction...3

More information

Remote Alarm Block 176S

Remote Alarm Block 176S Your Partners in Network Alarm Management Remote Alarm Block 176S USER MANUAL Visit our website at www.dpstelecom.com for the latest PDF manual and FAQs. November 7, 2003 D-OC-UM03B.07200 Firmware Version

More information

KUUMIC OY DATA TRANSFER FALLBACK SWITCH KU113. Technical Reference

KUUMIC OY DATA TRANSFER FALLBACK SWITCH KU113. Technical Reference FALLBACK SWITCH Technical Reference CONTENTS 1. GENERAL...1 1.1. INTRODUCTION...1 1.1.1. Basic functions...1 1.2. TECHNICAL SPECIFICATIONS...3 1.2.1. CONNECTORS...3 1.2.2. LED INDICATORS...5 1.2.3. JUMPERS

More information

ICS Regent. Relay Output Modules. Low Power and High Power (T3446L and T3446H) PD-6017

ICS Regent. Relay Output Modules. Low Power and High Power (T3446L and T3446H) PD-6017 ICS Regent PD-6017 Relay Output Modules Low Power and High Power (T3446L and T3446H) Issue 1, March, 06 Relay output modules provide control of eight user output loads. Two types of relay output modules

More information

PAC BI-DP BIM and 8701-CA-BI Carrier

PAC BI-DP BIM and 8701-CA-BI Carrier June 2013 PAC8000 8507-BI-DP BIM and 8701-CA-BI Carrier PROFIBUS DP Bus Interface Module and Carrier The 8507-BI-DP Bus Interface Module (BIM) provides the communications link between the PAC8000 series

More information

INSTRUCTION MANUAL STATION CONTROLLER SC1000 MOTOR PROTECTION ELECTRONICS, INC.

INSTRUCTION MANUAL STATION CONTROLLER SC1000 MOTOR PROTECTION ELECTRONICS, INC. INSTRUCTION MANUAL STATION CONTROLLER SC1000 MOTOR PROTECTION ELECTRONICS, INC. 2464 Vulcan Road, Apopka, Florida 32703 Phone: (407) 299-3825 Fax: (407) 294-9435 Revision Date: 9-11-08 Applications: Simplex,

More information

SMART SHOT CONTROLLER FLUID USERS GUIDE

SMART SHOT CONTROLLER FLUID USERS GUIDE SMART SHOT CONTROLLER FLUID USERS GUIDE Pg. 2 SMART SHOT CONTROLLER FEATURES 3 SMART SHOT CONTROLLER FEATURES 3 SMART SHOT CONTROLLER CONFIGURATIONS 4 FLOAT/SENSOR WIRING 5 TOP AND BOTTOM FLOAT/SENSOR

More information

Plus-X 600. Installation and Operation Manual

Plus-X 600. Installation and Operation Manual Plus-X 600 Installation and Operation Manual Table of Contents Introduction... 1 Compatibility... 1 Unpacking... 1 Front Panel Indicators... 2 Hardware Configuration... 2 Installation... 4 Software Configuration...

More information

CA-A480-A Elevator Controller. Reference & Installation Manual

CA-A480-A Elevator Controller. Reference & Installation Manual CA-A480-A Elevator Controller Reference & Installation Manual TABLE OF CONTENTS INTRODUCTION.................................................................. 4 Introduction.............................................................................................

More information

Integriti 8-32 Zone LAN Expander Module Kit INSTALLATION MANUAL

Integriti 8-32 Zone LAN Expander Module Kit INSTALLATION MANUAL Revision 2.1 July. 2014 1 Integriti 8 32 Zone LAN Expander Module Kit P/N: 996005PCB&K For Rev. B PCB. INSTALLATION MANUAL Overview The Integriti 8 Zone Expander Module provides an additional 8 Zone inputs,

More information

STATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

STATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free Instruction Manual Model 1582-45L Data Switch September 2010, Rev A REMOTE LOCAL SWITCH STATUS SELECT REMOTE LOCAL LOCAL SELECT CHANNEL SELECT POWER MODEL 1582 SWITCH CROSS TECHNOLOGIES, INC. Data, drawings,

More information

POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free Instruction Manual Model 1582-10M Protection Switch January 2009 Rev O ALARMS MENU OUTPUT = CH1 AUTO POWER 1 2 MODEL 1582 SWITCH CROSS TECHNOLOGIES INC. CH1 CH2 REMOTE EXECUTE Data, drawings, and other

More information

MODEL 2310 AL MCS-11 REMOTE ENCODER. FIAL INCORPORATED 710 Center Street Oregon City, OR

MODEL 2310 AL MCS-11 REMOTE ENCODER. FIAL INCORPORATED 710 Center Street Oregon City, OR MODEL 2310 AL MCS-11 REMOTE ENCODER FIAL INCORPORATED 710 Center Street Oregon City, OR 97045 503.607.1940 WWW.FIAL.COM DOCUMENT NUMBER FC2310_AL-040506 COPYRIGHT 2004 BY FIAL INCORPORATED NOTICE OF FCC

More information

INDEX. Network Power Monitor NPM-R10-SNMP. Innovative Electronics for a Changing World. NPM-R10-SNMP Remote Network Power Monitor

INDEX. Network Power Monitor NPM-R10-SNMP. Innovative Electronics for a Changing World. NPM-R10-SNMP Remote Network Power Monitor Innovative Electronics for a Changing World NPM-R10-SNMP Remote Network Power Monitor Optional relay board and GSM module INDEX 1. SYSTEM DESCRIPTION 2. SYSTEM BATTERY CONNECTIONS 3. SERIES CONNECTED BATTERIES

More information

SmartLock Controller INSTALLATION MANUAL

SmartLock Controller INSTALLATION MANUAL SmartLock Controller INSTALLATI MANUAL November 2015 Table of Contents INTRODUCTI... 3 Diodes... 4 Terminal Strips and Cable... 5 SPECIFICATIS... 6 SMARTLOCK CTROLLER LAYOUT... 8 LED Indicators... 9 Mounting...

More information

MODEL 2310 MCS-11 REMOTE ENCODER. FIAL INCORPORATED 710 Center Street Oregon City, OR

MODEL 2310 MCS-11 REMOTE ENCODER. FIAL INCORPORATED 710 Center Street Oregon City, OR MODEL 2310 MCS-11 REMOTE ENCODER FIAL INCORPORATED 710 Center Street Oregon City, OR 97045 503.607.1940 WWW.FIAL.COM COPYRIGHT 2001 BY FIAL INCORPORATED NOTICE OF FCC COMPLIANCE NOTE This equipment has

More information

BA/BS4S Temperature Sensor Installation & Operating Instructions

BA/BS4S Temperature Sensor Installation & Operating Instructions Product Overview and Identification The BAPI-Stat 4 room temperature sensor features a large format LCD and slider setpoint adjustment. Additional options include button override and communication jack.

More information

NETWORK CONCENTRATOR LINK. This equipment must only be installed and serviced by professional qualified personnel.

NETWORK CONCENTRATOR LINK. This equipment must only be installed and serviced by professional qualified personnel. Revised! see Protective Earthing Addendum cback NOTE: This equipment must only be installed and serviced by professional qualified personnel. The Network Concentrator Link is a fully self contained unit

More information

I/O Expansion Module Installation & Reference

I/O Expansion Module Installation & Reference Overview The In-Sight vision sensor supports up to ten discrete inputs and ten discrete outputs. Two inputs and two outputs are built-in to the In-Sight processor. The remaining eight inputs and outputs

More information

CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE

CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE 13050201 (c) Copyright DIP Inc., 1996 DIP Inc. P.O. Box 9550 MORENO VALLEY, CA 92303 714-924-1730 CONTENTS DN502 PRODUCT OVERVIEW 1 DN502 INSTALLATION 1 POWER

More information

GreenEye Monitor Specifications

GreenEye Monitor Specifications Number of Channels Power Monitoring Section 32 (expansion available in the future) Measurement POWER: True (or Real) Power using high speed volt and current sampling VOLTAGE: True RMS Accuracy Sampling

More information

CA111x-series Arming Station

CA111x-series Arming Station GE Security CA111x-series Arming Station Installation and Programming Guide Contents Page Product Overview...1 Removing the Covers...2 Mounting the RAS...3 Tamper Switch...3 DIP Switch Settings...3 Connections...4

More information

PGR-2601 MANUAL DC GROUND-FAULT RELAY

PGR-2601 MANUAL DC GROUND-FAULT RELAY POWR-GARD Ungrounded DC System PGR-2601 SERIES DC Ground-Fault Relay PGR-2601 MANUAL DC GROUND-FAULT RELAY AUGUST 31, 2009 REVISION 1 POWR-GARD DC GROUND-FAULT RELAY PWR TRIP 5 4 3 2 6 - BUS 8 10 15 20

More information

CDN503 HIGH DENSITY I/O ADAPTER USER GUIDE

CDN503 HIGH DENSITY I/O ADAPTER USER GUIDE CDN503 HIGH DENSITY I/O ADAPTER USER GUIDE 13050301 (c) Copyright DIP Inc., 1996 DIP Inc. P.O. Box 9550 MORENO VALLEY, CA 92303 714-924-1730 CONTENTS DN503 PRODUCT OVERVIEW 1 DN503 INSTALLATION 1 POWER

More information

Redundant System Redundant System P9-1-1

Redundant System Redundant System P9-1-1 .. P-- Overview - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - P-- idcs-8830/idcs-8830r - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

More information

CRAGG RAILCHARGER Instruction Manual for 10DTC-12V 20DTC-12V 30DTC-24V 40DTC-12V 60DTC-12V

CRAGG RAILCHARGER Instruction Manual for 10DTC-12V 20DTC-12V 30DTC-24V 40DTC-12V 60DTC-12V CRAGG RAILCHARGER for 10DTC-12V 20DTC-12V 30DTC-24V 40DTC-12V 60DTC-12V Contents 1 Warnings, Cautions, and Notes... 1 2 Description... 2 3 Features... 2 3.1 STANDARD FEATURES... 2 3.2 CHARGER REGULATION...

More information

DIGITAL DISPLAY. for Industry Applications. Series PAXD. Key-Features:

DIGITAL DISPLAY. for Industry Applications. Series PAXD. Key-Features: DIGITAL DISPLAY for Industry Applications Series PAXD Key-Features: Content: Technical Data.2 Technical Drawing...2 Electrical Connection...3 Plug-In Cards...4 Programming & Software...5 Order Code & Accessories...6-5

More information

Quick Start Installation Guide

Quick Start Installation Guide apc/l Quick Start Installation Guide Version A2 Document Part Number UM-201 May 2010 OVERVIEW The apc/l is an intelligent access control and alarm monitoring control panel which serves as a basic building

More information

SPX-7400_SPX-7410_MAN_161028

SPX-7400_SPX-7410_MAN_161028 Suprex Fiber Optic SPX-7400 & SPX-7410 Suprex Reader-Extender Data Sheet SPX-7400 Series EXP-2000 SPX-7400_SPX-7410_MAN_161028 1 Cypress Suprex SPX-7400 & SPX-7410 Overview The Suprex Fiber Optic SPX-7400

More information

9212i INSTALLATION. Stand-Alone Keypad. Instructions

9212i INSTALLATION. Stand-Alone Keypad. Instructions INSTALLATION 9212i Stand-Alone Keypad Instructions Features: 4 Independent Outputs 4 Independent Timers All Outputs Assignable by Code On board 5 Amp Form C Relay 120 Users Remote Triggering Input Keypad

More information

Model 620A Maintenance and Calibration

Model 620A Maintenance and Calibration Model 0A Maintenance and Calibration CAUTION! See Ch Pg, A & B below prior to connecting inputs to TB of the A PCB. Determine Rev. of the A board on the Model 0/0A for correct input connections. Failure

More information

DUAL SWITCH CONTROLLER

DUAL SWITCH CONTROLLER DUAL SWITCH CONTROLLER INSTRUCTION MANUAL IMPORTANT: If the Dual Switch Controller is to be used with a Dielectric 50000 Series Switch, control cable P/N 1100007364 or 11000007365 must be used. See Section

More information

NetGuardian 832A G4 USER MANUAL. February 6, Firmware Version 4.11 D-UM-NETG4

NetGuardian 832A G4 USER MANUAL. February 6, Firmware Version 4.11 D-UM-NETG4 NetGuardian 832A G4 USER MANUAL February 6, 208 D-UM-NETG4 Firmware Version 4. Revision History February 6, 208 Updated Display Map for XBEE sensors August 28, 202 Updated part number for new RoHS ethernet

More information

UC-2000 Installation Manual Unicorn Computers Technology Limited

UC-2000 Installation Manual Unicorn Computers Technology Limited UC2000 Installation Manual Copyright 2003. All rights reserved. Table of Contents Specifications 2 Enclosure for the UC2000 Controller 3 Unicorn Access Control System Configuration 4 UC2000 Controller

More information

POWERWISE INDAC SETUP MANUAL

POWERWISE INDAC SETUP MANUAL POWERWISE INDAC SETUP MANUAL REVISION: 2.2 INDAC & EMONITOR GATEWAY An installation guide for the PowerWise indac. 2013 PowerWise, Inc. This manual may contain proprietary information about the product

More information

CMSA-100 Manual. Cinema Media Server Automation

CMSA-100 Manual. Cinema Media Server Automation CMSA-100 Manual Cinema Media Server Automation 181 Bonetti Drive San Luis Obispo, CA 93401-7397 USA Phone: +1 805 549 0161 Fax: +1 805 549 0163 www.uslinc.com Table of Contents 1. Safety Notice... 3 2.

More information

180 Series Keypad. Handbook. Revision 2.1

180 Series Keypad. Handbook. Revision 2.1 180 Series Keypad Handbook Revision 2.1 Revision History Revision 1.0 Initial release Revision 2.0 Major update with addition of 180-40 Added 180-40 to document and various headings Note regarding unique

More information

Table of Contents 1 ABOUT THIS DOCUMENT GENERAL COPYRIGHT INFORMATION TERMS ABOUT THE GATEWAY PRODUCT FUNCTIO

Table of Contents 1 ABOUT THIS DOCUMENT GENERAL COPYRIGHT INFORMATION TERMS ABOUT THE GATEWAY PRODUCT FUNCTIO DeviceNet/PROFIBUS-DP Adapter - User Manual REV 4.0 SiboTech Automation Co., Ltd. Technical Support: +86-21-5102 8348 E-mail:gt@sibotech.net Table of Contents 1 ABOUT THIS DOCUMENT...2 1.1 GENERAL... 2

More information

INDEX. Network Power Monitor R10 SNMP

INDEX. Network Power Monitor R10 SNMP Innovative Electronics for a Changing World NPM-R10 Remote Network Power Monitor With optional relay board and GSM module INDEX Amended 21 March 2017: Add user defined Password see page 13 Add wire Connection

More information

Simplified information where and how you want it.

Simplified information where and how you want it. ConsolIdator 4 & 8 Multi-channel controllers Simplified information where and how you want it. ConsoliDator 4 Model PD940 ConsoliDator ConsoliDator 4 Features Four 4-20 Inputs Four 4-20 Outputs ConsoliDator

More information

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual This package is designed to simplify the connections to our Secured Series Hub Plus Controller. This will translate into

More information

NX21 USER MANUAL. Telemetry Unit. Version 1.5

NX21 USER MANUAL. Telemetry Unit. Version 1.5 USER MANUAL Version 1.5 Nortech Management Ltd, United Kingdom NOV 2016 www.nortechonline.co.uk Doc Ref D_000344 Publication Notice Copyright Nortech Management Limited (NML). All rights reserved. No part

More information

Used in conjuction with UM

Used in conjuction with UM Your Partners in Network Alarm Management Visit our website at www.dpstelecom.com for the latest PDF manual and FAQs. July 19, 2001 UM00C.30240 Firmware: 2.1-2.5 Used in conjuction with UM006.12201 Revision

More information

Plus-X 300. Installation and Operation Manual

Plus-X 300. Installation and Operation Manual Plus-X 300 Installation and Operation Manual Table of Contents Introduction... 1 Compatibility... 1 Installation... 1 Configuration... 2 Operation... 5 Getting Help... 6 Warranty... 6 Appendix A: Specifications...

More information

HydroLynx Systems, Inc. Model 50386D Decoder Instruction Manual

HydroLynx Systems, Inc. Model 50386D Decoder Instruction Manual HydroLynx Systems, Inc. Model 50386D Decoder Instruction Manual Document No: WD102681-1 Document Revision Date: April, 2011 HydroLynx Systems, Inc. Model 50386D Decoder Receiving and Unpacking Carefully

More information

MCX402DR-BRD I/O expander. Operating Manual

MCX402DR-BRD I/O expander. Operating Manual Roger Access Control System MCX402DR-BRD I/O expander Operating Manual Product version: 1.0 Firmware version: 1.0.2.255 Document version: Rev. B Design and application The MCX402DR-BRD is I/O expander

More information

BENCHMARK MEDIA SYSTEMS, INC.

BENCHMARK MEDIA SYSTEMS, INC. BENCHMARK MEDIA SYSTEMS, INC. RLY-106 Instruction Manual 1.0 Introduction...1 2.0 Input and Output Connections...1 2.1 Connection Alternatives...2 3.0 Relay Ratings...2 4.0 Applications...4 4.1 Audio Signal

More information

Intech Micro 2300-RO4 analogue input station MODBUS RTU slave application supplementary manual.

Intech Micro 2300-RO4 analogue input station MODBUS RTU slave application supplementary manual. Intech Micro 2300-RO4 analogue input station MODBUS RTU slave application supplementary manual. MODBUS supplementary manual to the 2300-RO4 Installation Guide. The 2300 series stations are designed to

More information

5450 NW 33rd Ave, Suite 104 Fort Lauderdale, FL Fruitland Ave Los Angeles, CA SST7000 SST7100. Speed Switch / Transmitter

5450 NW 33rd Ave, Suite 104 Fort Lauderdale, FL Fruitland Ave Los Angeles, CA SST7000 SST7100. Speed Switch / Transmitter 5450 NW 33rd Ave, Suite 104 Fort Lauderdale, FL 33309 3211 Fruitland Ave Los Angeles, CA 90058 SST7000 SST7100 Speed Switch / Transmitter Installation and Operation Manual Rev. C P/N145F-13112 PCO 00009270

More information

Innovative Electronics for a Changing World. Charge Smart R1 MPPT 12V/24V Auto detect Mains and Solar Battery charger with Remote Network Monitoring

Innovative Electronics for a Changing World. Charge Smart R1 MPPT 12V/24V Auto detect Mains and Solar Battery charger with Remote Network Monitoring Innovative Electronics for a Changing World Charge Smart R1 MPPT 12V/24V Auto detect Mains and Solar Battery charger with Remote Network Monitoring INDEX 1. SYSTEM DESCRIPTION 2. SYSTEM WIRING 3. SYSTEM

More information

1. Carefully unpack the um260 s shipping carton and check the contents for damage.

1. Carefully unpack the um260 s shipping carton and check the contents for damage. um260 Installation Manual um260 Installation Chapter 4 um260 MICRO MONITOR INSTALLATION This section of the um260 Micro Monitor Installation Manual describes the requirements and procedures for installing

More information

Suprex Fiber Optic. Reader-Extender SPX-7400 SPX Product Manual. Reader-Extender. Manual. SPX-7400 Series EXP Suprex_FiberOptic_MAN_170502

Suprex Fiber Optic. Reader-Extender SPX-7400 SPX Product Manual. Reader-Extender. Manual. SPX-7400 Series EXP Suprex_FiberOptic_MAN_170502 Suprex Fiber Optic Reader-Extender SPX-7400 SPX-7410 Product Manual Reader-Extender Manual SPX-7400 Series EXP-2000 Suprex_FiberOptic_MAN_170502 Cypress Integration Solutions 30+ Years of Access Control

More information

About this Manual. Description

About this Manual. Description About this Manual This manual is a comprehensive guide that contains all of the information necessary to install and operate the Balluff BDD-100 Position Display. Please read this manual completely. For

More information

IntesisBox Modbus Server KILSEN KSA-7xx. User s Manual 08/2013 r1.2 eng

IntesisBox Modbus Server KILSEN KSA-7xx. User s Manual 08/2013 r1.2 eng IntesisBox Modbus Server KILSEN KSA-7xx User s Manual 08/2013 r1.2 eng Intesis Software S.L. 2013 All rights reserved. Information in this document is subject to change without notice. The software described

More information

SmartLock Pro INSTALLATION MANUAL

SmartLock Pro INSTALLATION MANUAL SmartLock Pro INSTALLATI MANUAL July 2010 Cutting edge simplicity Table of Contents INTRODUCTI... 3 Diodes... 3 Power Supply Notice... 3 Terminal Strips and Cable... 4 SPECIFICATIS... 5 SMARTLOCK CTROLLER

More information

Standard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter

Standard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter Standard Options Model 4100 Position Indicating Meter A percent-of-full-travel meter is supplied with a trim potentiometer resistor, terminal block and connectors. A potentiometer is required in the actuator

More information

Analog Output Isolators

Analog Output Isolators TURCK Interface Technology Analog output isolators are for use with conventional 4/20 ma or HART smart "IS" devices are available in 1 and 2 channel versions. These devices are designed to provide a convenient

More information

LASER PLUS OPERATING INSTRUCTIONS

LASER PLUS OPERATING INSTRUCTIONS LASER PLUS OPERATING INSTRUCTIONS Phone: (209) 586-1022 (800) 545-1022 Fax: (209) 586-1026 E-Mail: salessupport@olsontech.com 025-370403 REV X9 www.olsontech.com 12/16/03 TABLE OF CONTENTS SYSTEM OVERVIEW

More information

GF-1. Introduction. 1 Features. +-10G Tilt Compensated dual range aviation G-force meter. Operating Manual English 1.00

GF-1. Introduction. 1 Features. +-10G Tilt Compensated dual range aviation G-force meter. Operating Manual English 1.00 GF-1 +-10G Tilt Compensated dual range aviation G-force meter Operating Manual English 1.00 Introduction The GF-1 is a 2.25 G-force meter capable of measuring G-forces exerted in an aircraft up to +-10G.

More information

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies ADC7520 SERIES 1600W Battery Chargers and Power Supplies Wide output adjustment range 0 72VDC Analog control by external 0-5VDC voltage Temp.comp charging, sense as on option Power fail relay alarm Master-Slave

More information

AS Keypad User Manual

AS Keypad User Manual AS Keypad User Manual Specifications Operating Voltage: 12~24 VAC/DC Current Draw: TBA Input: request-to-exit (for Relay 1) time out reed switch contact (for Relay 1) Output: Relay 1: N.O./N.C./Com. Output

More information

Torque Control Verifier

Torque Control Verifier Torque Control Verifier Instruction Manual Revision 1.2 September 2002 Please Read and Understand Instructions Before Attempting Installation Torque Control Verifier Contents: Quick Start Introduction

More information

Intelligent Devices IDI 6005 Speed Sign Controller Technical Manual

Intelligent Devices IDI 6005 Speed Sign Controller Technical Manual Intelligent Devices IDI 6005 Speed Sign Controller 4411 Suwanee Dam Road, Suite 510 Suwanee, GA 30024 T: (770) 831-3370 support@intelligentdevicesinc.com Copyright 2011, Intelligent Devices, Inc. All Rights

More information

Controller Extension Box

Controller Extension Box Controller Extension Box USER MANUAL Visit our website at www.dpstele.com for the latest PDF manual and FAQs. November 18, 2015 D-UM-CTLEX Revision History November 18, 2015 Specs update November 21, 2012

More information

DAC-P USER MANUAL. Visit our website at for the latest PDF manual and FAQs.

DAC-P USER MANUAL. Visit our website at  for the latest PDF manual and FAQs. Your Partners in Network Alarm Management DAC-P USER MANUAL Visit our website at www.dpstelecom.com for the latest PDF manual and FAQs. February 13, 2003 D-OC-UM032.13200 Firmware Version 1.0D Revision

More information

The Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits.

The Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits. Peripheral Relay The Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits. Up to 16 Cards can be connected to a multi-loop panel

More information

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS MAINTENANCE MANUAL EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS SPECIFICATIONS*... 2 INTRODUCTION... 3 DESCRIPTION...

More information

REQUIREMENTS FOR WIRELESS, WEB-BASED MONITORING EQUIPMENT AND SERVICES FOR PUMP STATION APPLICAITONS

REQUIREMENTS FOR WIRELESS, WEB-BASED MONITORING EQUIPMENT AND SERVICES FOR PUMP STATION APPLICAITONS REQUIREMENTS FOR WIRELESS, WEB-BASED MONITORING EQUIPMENT AND SERVICES FOR PUMP STATION APPLICAITONS MANUFACTURER REQUIREMENTS The Manufacturer of the equipment and provider of related services shall provide

More information

D/E Remote Relay Panel User Guide

D/E Remote Relay Panel User Guide D/E Remote Relay Panel User Guide This manual should remain with the unit. D/E Remote Relay Panel Detailed Specifications...2 Environmental Specs...2 Power Supply Requirements...2 Relay Outputs (8)...2

More information

Table of Contents 1 ABOUT THIS GUIDE CONTACT INFORMATION ANTENNA INSTALLATION... 4

Table of Contents 1 ABOUT THIS GUIDE CONTACT INFORMATION ANTENNA INSTALLATION... 4 Table of Contents 1 ABOUT THIS GUIDE... 3 1.1 CONTACT INFORMATION... 3 2 ANTENNA INSTALLATION... 4 2.1 GENERAL INFORMATION... 4 2.2 SPECIFIC MOUNTING EXAMPLES... 5 2.3 CONNECTOR MOISTURE PROTECTION...

More information

Intech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual.

Intech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual. Intech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual. MODBUS supplementary manual to the 2300-A8VI Installation Guide. The 2300 series stations are designed to

More information

GSM Controller BR160SM-2FLOW-4A-A / BR161SM-2FLOW-4A-A Preliminary data

GSM Controller BR160SM-2FLOW-4A-A / BR161SM-2FLOW-4A-A Preliminary data GSM Controller BR160SM-2FLOW-4A-A / BR161SM-2FLOW-4A-A Preliminary data Version for flow (pulses), analog and digital signal monitoring GSM module for SMS remote monitoring and control applications Features

More information

Flomatic Smart Card TM Model FDHC-100 (Digital High-Resolution Controller) Configuration and Operation Manual

Flomatic Smart Card TM Model FDHC-100 (Digital High-Resolution Controller) Configuration and Operation Manual The Flomatic FDHC-100 is a high performance Digital positioner intended to control AC actuators, providing 450 points of resolution with quarter turn actuators ranging from 2 sec to 120 sec and rated for

More information

4170 POS System Installation Guide

4170 POS System Installation Guide 4170 POS System 4170 Installation Guide Thank you for selecting UTC RETAIL s innovative Model 4170 Point of Sale solution! This Installation Guide will help you efficiently install the 4170 POS. The document

More information

Security Management System by Diebold, Inc. LINX System Hardware Installation Guide

Security Management System by Diebold, Inc. LINX System Hardware Installation Guide Security Management System by Diebold, Inc. LINX System Hardware Installation Guide INSTALLATION GUIDE LINX Integrated Security System WSD 2000 Weatherized Status Display Table of Contents Introduction

More information

High Voltage DC Meter

High Voltage DC Meter High Voltage DC Meter Javelin D PD644 0-300 VDC input NEMA 4X, IP65 front Scale in engineering units Sunlight readable LED display 4-20 ma analog output Two form C 3 A relays option RS-485 serial communications

More information

User's Guide. CIO-RELAY08 CIO-RELAY16 CIO-RELAY24 CIO-RELAY32

User's Guide.    CIO-RELAY08 CIO-RELAY16 CIO-RELAY24 CIO-RELAY32 User's Guide http://www.omega.com e-mail: info@omega.com CIO-RELAY CIO-RELAY6 CIO-RELAY CIO-RELAY3 For Your Notes Table of Contents INTRODUCTION.... ACCESSORIES... QUICK START.... Install the InstaCalTM

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS LIGHTING CONTROL PANELS 16 AND 24 RELAYS INSTALLATION INSTRUCTIONS INSTALLATION OVERVIEW The installation instructions contained in this document are provided as a guide for proper and reliable installation.

More information

Table of Contents. 1 Introduction Introduction Front Panel Description Rear Panel Description 3

Table of Contents. 1 Introduction Introduction Front Panel Description Rear Panel Description 3 Chapter Page 1 Introduction 1 1.1 Introduction 1 1.2 Front Panel Description 2 1.3 Rear Panel Description 3 Table of Contents 2 Installation and Operation 4 2.1 Mounting Instructions 4 2.2 Power Connections

More information

Dim levels for each system output may be controlled by any of the following methods:

Dim levels for each system output may be controlled by any of the following methods: Applied Electronics Bravo Series Dimming System Rack-Mount Architectural l SA12/2400A and l SA12/2400E Setup and Operation Instructions 1.0 Scope This document details the setup and operation requirements

More information

ASYNC Sharing Unit TABLE OF CONTENTS SECTION 1 - DESCRIPTION...2 SECTION 2 - SPECIFICATIONS...5 SECTION 3 - INSTALLATION...7

ASYNC Sharing Unit TABLE OF CONTENTS SECTION 1 - DESCRIPTION...2 SECTION 2 - SPECIFICATIONS...5 SECTION 3 - INSTALLATION...7 ASYNC Sharing Unit TABLE OF CONTENTS SECTION 1 - DESCRIPTION... SECTION - SPECIFICATIONS... SECTION - INSTALLATION... SECTION - FRONT PANEL CONTROLS AND INDICATORS...9 SECTION - NETWORK MANAGEMENT PORT...10

More information

TC1900 "QUICK TALK" RS-232 or Fiber Telephone Extender User's Manual

TC1900 QUICK TALK RS-232 or Fiber Telephone Extender User's Manual "QUICK TALK" RS- or Fiber Telephone Extender MODEL: S/N: DATE: Notice! Although every effort has been made to insure that this manual is current and accurate as of date of publication, no guarantee is

More information

MCCB-500 MOLDED-CASE CIRCUIT BREAKER TESTER

MCCB-500 MOLDED-CASE CIRCUIT BREAKER TESTER MCCB-500 MOLDED-CASE CIRCUIT BREAKER TESTER USER S MANUAL Vanguard Instruments Company, Inc. 1520 S. Hellman Ave. Ontario, California 91761, USA TEL: (909) 923-9390 FAX: (909) 923-9391 January 2015 Revision

More information

S125 Multi-Purpose 125 KHz RFID Reader USER MANUAL. 9V/24V DC Operating Voltage, AC (optional) KHz RFID EM4100/2 Cards & Tags

S125 Multi-Purpose 125 KHz RFID Reader USER MANUAL. 9V/24V DC Operating Voltage, AC (optional) KHz RFID EM4100/2 Cards & Tags S125 Multi-Purpose 125 KHz RFID Reader 44 mm USER MANUAL MULTI PURPOSE 84 mm ONLINE & OFFLINE MODE BUILT-IN RELAY 125 KHz RFID EM4100/2 Cards & Tags 9V/24V DC Operating Voltage, AC (optional) 3 Online

More information

PEAKTRONICS DHC-100 FEATURES. Digital High-Resolution Controller

PEAKTRONICS DHC-100 FEATURES. Digital High-Resolution Controller PEAKTRONICS The Peaktronics is a high performance digital positioner intended to control AC actuators, providing 450 points of resolution with quarter turn actuators ranging from sec to 0 sec and rated

More information

Intelligent Devices IDI 1100 Series Technical Manual

Intelligent Devices IDI 1100 Series Technical Manual Intelligent Devices IDI 1100 Series 4411 Suwanee Dam Road, Suite 510 Suwanee, GA 30024 T: (770) 831-3370 support@intelligentdevicesinc.com Copyright 2011, Intelligent Devices, Inc. All Rights Reserved

More information

Stellar Instruments. SC1 Controller & Display System. General User s Manual. Copyright 2013 Stellar Instruments 1

Stellar Instruments. SC1 Controller & Display System. General User s Manual. Copyright 2013 Stellar Instruments 1 Stellar Instruments SC1 Controller & Display System General User s Manual Copyright 2013 Stellar Instruments 1 Contents Section 1 General... 3 Section 2 Base Unit A (Multi-Event Programmable Timer)...

More information

DC3IOB Revision User Guide Updated 3/29/10. Overview

DC3IOB Revision User Guide Updated 3/29/10. Overview Revision 080910 User Guide Updated 3/29/10 Overview The is a three axis DC brush motor drive with an integrated PLC. A range of motor drive currents are selectable with jumper blocks. The integrated PLC

More information