COMMONLY USED 5.AFETY SENSORS. Photocell (Reflector) CLOSING Direction. Photocell (Reflector) CLOSING Direction OA4RO E.3IC-RIOIC4 EA4X IRB-RET

Size: px
Start display at page:

Download "COMMONLY USED 5.AFETY SENSORS. Photocell (Reflector) CLOSING Direction. Photocell (Reflector) CLOSING Direction OA4RO E.3IC-RIOIC4 EA4X IRB-RET"

Transcription

1 MLY USED 5.AFETY SENSORS OA4RO E.IC-RIOIC4 Direction. Set switch to "LIGHT ". Wire V power to photocell. Wire to photocell N0 Wire to photocell C- 4. Align photocell to reflector 5. Adjust sensitivity I O I = I ICLS NC I ; I EI EI El EI 0 EI 0 ICLS 0K EI 0 EI El === NOTE: DO NOT use 0K Resisitor included with photocell. OK to use VDC NOTE: To meet the UL 5 08 standard, Type B Non-Contact sensor entrapment protection device MUST be MITORED by the gate operator. IMPORTANT: Photocell MUST be in alignment with reflector or fault will occur. EA4X IRB-RET Direction IMPORTANT: Photocell MUST be powered by MATRIX Ill or it will NOT be MITORED. NOTE: To meet the UL 5 08 standard, Type B Non-Contact sensor entrapment protection device MUST be MITORED by the gate operator.. Set DIP-switches. Remove jumpers JP-5 and JP-6. Wire V power to photocell (VRX) 4. Wire Matrix Ill to photocell NC (Energized) Wire Matrix Ill to photocell (Energized) 5. Align photocell to reflector 6. Adjust sensitivity UL 5 08 Standard PR0/00 PRO/F8 PRO Matrix Ill Install Version

2 emx irb-mon Transmitter (TX) direction Thru-Beam Receiver (RX) Photocell (Thru-Beam) Direction Single Gate Operator To and Input To Matrix III Input Transmitter (TX) TX POWER TRANSMITTER BOARD (TX) Green LED Gate Closed Single Operator. Set DIP-switches on receiver.. Install jumper on receiver.. Wire Matrix III power to receiver. 4. Wire to receiver photocell NC. Wire Matrix III to receiver photocell. 5. Wire V Matrix III power to transmitter. 6. Align photocells.. Adjust sensitivity on receiver. TX RX Sensitivity Adjustment: If the photocell does not respond to an obstruction, lower the sensitivity by turning adjustment counter-clockwise. DIP-switches:,, are. Switch 4 is If trouble occurs, try turning switch 4. NOTE: Power must be cycled when switches are changed. Jumper MUST be on Com-NC. NO ComNC NO NC JUMPER IMPORTANT: Photocells MUST be in alignment or fault will occur. Green LED will remain receiver when in proper alignment. Receiver (RX) NC RX NO 4 DIP POWER RECEIVER BOARD (RX) SENSITIVITY EARTH Green LED IMPORTANT: Photocells MUST be powered by Matrix III or they will NOT be MITORED. Jumper UL SENSOR SOR N.C. - Normally Closed - Common NOTE: To meet the UL 5 08 standard, Type B Non-Contact sensor entrapment protection device MUST be MITORED by the gate operator.

3 omron EK-R0K4 wiring for max pro UL5-06 NORMALLY D (NC) Wiring to EK Photocell Direction UL5-08 NORMALLY D (NC) Wiring to EK Photocell Direction UL 08 Label on packaging NOTE: To meet the UL 5 06 standard, Type B Non-Contact sensor entrapment protection device MUST be MITORED by the gate operator. Set switch to LIGHT NOTE: To meet the UL 5 08 standard, Type B Non-Contact sensor entrapment protection device MUST be MITORED by the gate operator. Set switch to LIGHT Min Max SENSITIVITY LIGHT DARK Min Max SENSITIVITY LIGHT DARK. Set switch to LIGHT. Wire V power to photocell. Wire to photocell NO Wire to photocell C- 4. Align photocell to reflector 5. Adjust sensitivity C- NO NC Sensitivity Adjustment: If the photocell does not respond to an obstruction, lower the sensitivity by turning adjustment counter-clockwise. DO NOT connect to NC #. Power. Set switch to LIGHT. Wire V power to photocell. Wire to photocell NO Wire to photocell C 4. Align photocell to reflector 5. Adjust sensitivity Sensitivity Adjustment: If the photocell does not respond to an obstruction, lower the sensitivity by turning adjustment counter-clockwise. DO NOT connect to NC #4. C- NO NC NC N0 C Power C- NO to 40 VAC 4 to 40 VDC N0 C 4 to 40 VAC 4 to 40 VDC UL SENSOR SOR N.C. VDC Out Monitored IMPORTANT: Photocell MUST be powered by Monitored or it will NOT be MITORED. OK to use VDC UL SENSOR SOR N.C. VDC Out Monitored IMPORTANT: Photocell MUST be powered by Monitored or it will NOT be MITORED. OK to use VDC NOTE: DO NOT use 0K Resistor included with photocell. For 0K Resistor EK Photocell wiring see next page

4 omron EK-R0K4 wiring for max pro UL5-08 0K Resistor wiring to EK Photocell Min Max SENSITIVITY Set switch to LIGHT LIGHT DARK Direction. Set switch to LIGHT. Wire V power to photocell. Wire to photocell NC Wire to photocell C- 4. Align photocell to reflector 5. Adjust sensitivity Sensitivity Adjustment: If the photocell does not respond to an obstruction, lower the sensitivity by turning adjustment counter-clockwise. C- NO NC NC N0 C Power C NC 4 to 40 VAC 4 to 40 VDC UL 08 Label on packaging UL SENSOR N.C. OK to use VDC NOTE: To meet the UL 5 08 standard, Type B Non-Contact sensor entrapment protection device MUST be MITORED by the gate operator.

5 EMX WEL-00 Wiring Guide FOR PRO SERIES RECEIVER WEL-00R TRANSMITTER TRANSMITTER WEL-00T WEL-00T WIRE WEL-00R & RELAYS TO MATRIX III 0K SENSOR S EMX WEL-00R INSERT BOTH JUMPERS IN 0K POSITI POWER / SOLAR IN MODULE PORT RESET / MANUAL RELEASE ALARM ID PLUG ERROR ID PLUG EXIT PWR EXIT LOOP CENTER LOOP LOOP PWR SAFETY LOOP FAULTS 4VDC OUTPUT PUT ERROR IN USE MODE A MODE B POWER VOLTAGE E / F TEST SENSE OBD PORT BLACK BOX PROGRAMG PROGRAM SOLAR MODE PRIMARY 6 4 OPERATOR SECDARY REPLACE BACKUP MODE LEAVE ERD SENSITIVITY 4 6 ERD OVER SENSE LOAD MOTI CTROL QUICK LEAVE D TIME MATRIX III SWING / SLIDE STOP GATE SPEED LINK OK ERD OVER LOAD TIMER JOG MAGLOCK DELAY UL ENTRAP S POSITI S MAG LOCK SLIDER LIMIT SWING LIMIT NO NC Jumper JP- 0K Jumper JP- 0K RADIO SIGNAL RADIO FIRE DEPT STRIKE KEYPAD / CARD MANUAL RELEASE PRIMARY/ SECDARY LINK (+) (-) LEFT GATE MATRIX III RIGHT / LEFT RIGHT.5 sec.5 sec UL SENSOR N.C. GATE GATE D STOP GATE DISABLE TAMPER NO TAMPER IN JOG LEFT JOG RIGHT UL SENSOR N.C. WIRE TO NO OF RELAY WIRE TO NO OF RELAY Polarity does NOT matter for power

6 CNECTING RECEIVER (WEL-00R) TO TRANSMITTER (WEL-00T) Connecting is a two step process. First, on the receiver, press and hold the channel assignment switch until the green status LED begins rapidly flashing, then release; this will clear any existing assignment for that particular channel. Hold down the connection switch on the transmitter. If it is not currently connected to a receiver, it will begin flashing rapidly until successfully connecting. Detailed instructions are given below. If there are no existing connections, the receiver s status LED will blink rapidly while it is finding a clean operating frequency (this can last a few seconds) After initialization, the system status LED will flash on/off once every seconds STEPS Set channel to the desired / direction function using the MODE dip switch Install AA Lithium batteries in the WEL-00T (transmitter) The green LED on the transmitter will quickly flash x every two seconds Install a properly terminated edge to the transmitter (8.k or 0k termination) 4 On the receiver, hold down the desired channel assignment switch until all four channel LED s activate and the system status LED begins flashing rapidly, then release the switch. 5 On the transmitter, hold down the connection switch (next to the terminal block) The LED on the transmitter will begin flashing rapidly after ~4 seconds Upon successful connection, the LED will flash once every two seconds If the transmitter fails to connect, it will return to its initial state, with the LED flashing twice every two seconds. If this occurs, repeat step Testing TESTING Without activating the edge, observe the channel status LED, it should be. When the edge is activated, the receiver channel status LED will turn on and the corresponding / direction output will activate. The transmitter status LED will blink once every second when the edge is activated. If the channel does not exhibit this behavior, double check the edge wiring/termination and transmitter batteries.

7 matrix III led troubleshooting ID plug MUST be plugged in PRO PRO F8 PRO Matrix III LED Problem Condition IN ERROR LED is. IN USE LED is. ERROR. IN USE. VOLTAGE 4. REPLACE 5. POWER 6. ERD. SENSE 8. OVERLOAD. MANUAL RELEASE/RESET 0. OBD PORT. PROGRAM. ID PLUG ERROR. SOLAR MODE 4. PRIMARY/SECDARY 5. EXIT LOOP 6. CENTER LOOP. SAFETY LOOP 8. VDC. 4 VDC VOLTAGE (E / F) LEDs, only E is. REPLACE LED is. IN USE and POWER LED are FLASHING PRIMARY Matrix III LINK OK LED is SECDARY Matrix III LINK OK LED is UL Entrap LED is ERD LED is FLASHING PHOTO CLS LED is LED is PHOTO CLS LED is flashing LED is flashing LY LED is LY LED is FLASHING SENSE LED is MANUAL RELEASE/RESET LED is but manual release is not working OBD PORT LED is FLASHING PROGRAM LED is FLASHING F8 POWER / SOLAR IN MODULE PORT RESET / MANUAL RELEASE ALARM 4 5 ID PLUG 6 ERROR ID 4 5 PLUG EXIT PWR EXIT LOOP CENTER LOOP LOOP PWR SAFETY LOOP FAULTS 4VDC OUTPUT PUT ERROR IN USE MODE A MODE B RADIO SIGNAL RADIO POWER VOLTAGE E / F REPLACE TEST SENSE OBD PORT BLACK BOX PROGRAMG PROGRAM SOLAR MODE PRIMARY 6 FIRE DEPT 4 OPERATOR SECDARY OVER LOAD BACKUP MODE LEAVE ERD SENSITIVITY 4 6 ERD SENSE MOTI CTROL STRIKE KEYPAD / CARD MANUAL RELEASE LEAVE D QUICK TIME STOP GATE SPEED LINK OK PRIMARY/ SECDARY LINK (+) (-) MATRIX III SWING / SLIDE LEFT ERD OVER LOAD GATE MATRIX III RIGHT STOP GATE DISABLE 4. GATE SPEED 40. LINK OK 4. MANUAL RELEASE Normal LED 4 / / / 4 0 / 4 / / / 4 0 Table continued on next page TIMER / JOG LEFT MAGLOCK DELAY UL ENTRAP RIGHT.5 sec.5 sec UL SENSOR N.C. TAMPER NO TAMPER IN JOG LEFT JOG RIGHT S POSITI S MAG LOCK SLIDER LIMIT SWING LIMIT GATE GATE D NO NC Solution(s) for Problem Condition 0. TIMER. SLIDER LIMIT. /. QUICK 4. LEFT 5. RIGHT 6. GATE. GATE D 8. MAGLOCK. 0. PHOTO NC. / NC.. 4. LY 0K 5. / 0K 6.. UL ENTRAPMENT 8. GATE TAMPER. GATE DISABLE Plug not plugged in to IN port. AC power is lost, operator is in battery back-up mode. Check if Toroid box AC POWER / SWITCH is. Measure power input DC voltage on Matrix ( 4V/ - -pin black connector), (expected reading 4 VDC if AC on, 5VDC if on battery back-up). Battery is very LOW. Check if AC power / switch is. If so, check AC power. Battery needs to be replaced if TEST fails and REPLACE LED is. Battery not plugged in to port. Check if limit sensors are plugged into PRIMARY MATRIX III SLIDER LIMIT input. Check wiring between PRIMARY RS485 (+,-, gnd) and SECDARY RS485 (+,-, gnd) terminals, connect [(+) to (+)], [(-) to (-)] and [ to ]. Check if limit sensors are plugged into SECDARY Matrix III SLIDER LIMIT input. An entrapment event has occurred, check if an entrapment sensor was triggered (see if PHOTO CLS, LY, or /CLS LEDs are on). An ERD event may have occurred. Check for gate obstruction. ERD sensitivity is too high for application. Re-adjust ERD setting, (see 8 ). Sensor on PHOTO CLS or inputs (photocell or edge) may have detected an obstruction while closing gate. Photocell on PHOTO CLS or inputs is misaligned with reflector. Sensor on PHOTO CLS or CLS LY 0k inputs (photocell or edge) may not be wired properly, (see 5 ). Sensor is NOT a N.C. monitored sensor that is UL5 08 compliant. Sensor might need to be re-learned. Sensor is damaged or malfunctioning. Sensor on LY input (photocell or edge) may have detected an obstruction while cycling gate. Photocell on LY input is misaligned with reflector. Sensor on LY input (photocell or edge) may not be wired properly, (see 5 ). Sensor is NOT a N.C. monitored sensor that is UL5 08 compliant. Sensor on LY is damaged or malfunctioning. Sensor might need to be re-learned. MOST sensitive setting for ERD entrapment detection. Select a less sensitive setting (recommend level 0 thru 6) Connected external device to MANUAL RELEASE input is not working, check wiring. replace device. Up to 8000 event history and error codes are being downloaded to connected flash drive. Up to 5 min. Program button has been pressed and programming mode is active. Press button again to leave programming mode.

8 matrix III led continued Matrix III LED Problem Condition ID PLUG LED is FLASHING and board beeping SOLAR MODE LED is /CLS LED is /CLS LED is FLASHING OVERLOAD LED is EXIT LOOP LED is FLASHING or constantly SAFETY LOOP LED is FLASHING or constantly GATE DISABLE LED is MAG LOCK LED is FLASHING GATE TAMPER LED is FLASHING VDC LED is. 4VDC LED is SLIDER LIMIT LED is / LED is QUICK LED is GATE SPEED LEDs are but gate moves slowly. Normal LED or 4 Solution(s) for Problem Condition Insert ID PLUG module that is tethered to chassis into ID PLUG connector. Operator is being powered by solar panel LY. Sensor on /CLS input (photocell or edge) may have detected an obstruction while opening or closing gate. Photocell on /CLS input is misaligned with reflector. Sensor on /CLS input (photocell or edge) may not be wired properly, (see 5 ). Sensor is NOT a N.C. monitored sensor that is UL5 08 compliant. Sensor on /CLS is damaged or malfunctioning. Sensor might need to be re-learned. Check if gate is binding against catch post or bracket in opened or closed position. Check if gate moves manually with low resistance throughout its full range of motion. Check if chain is installed inline with idle wheels in both and D positions. Loop fault condition: Check if EXIT loop wires are connected into to loop input connector properly. Check if loop detector is inserted properly in Loop Rack slot. Set unique loop detector frequency for each loop detector used. Loop Detector might be defective. Replace defective loop detector. NOTE: RENO loop detector LED s flash as default, but function normally (ignore the flashing). Loop fault condition: check if SAFETY loop wires are connected into to loop input connector properly. Check if SAFETY loops are wired in series. Check if loop detector is inserted properly in Loop Rack slot. Set unique loop detector frequency for each loop detector used. Loop Detector might be defective. Replace defective loop detector. NOTE: RENO loop detector LED s flash as default, but function normally (ignore the flashing). Check if Gate Shut-off switch is, Turn it. If it is, cycle the switch ( then ). Check if the chain is dropped. If so, gate is disabled for safety. Re-install chain and cycle the "Gate Shut-off" switch ( then ) to enable operator. Check if an external device is triggering GATE DISABLE input. Disconnect devices individually to determine possible false triggering of GATE DISABLE. Maglock power is lost. Check if maglock power transformer is wired properly or needs to be replaced. Switch is set to delay but no maglock is connected. Set switch to Gate was manually moved off of its D position causing Tamper Relay to trigger for few seconds. Check for a short in wiring to connected device. DO NOT power external keypads or telephone entry to this port (only use for radio receiver / photocell). Only if factory installed plug is plugged in. Re-install plug into SWING LIMIT connection for swing gate operator. Batteries are turned. Turn toroid box AC POWER switch and batteries automatically turn. Quick Close feature is turned. If this feature is not desired, turn quick close. Check if and Limits have been learned. Refer to Learn Gate Positions (see ). LY Maximum settings will turn LEDs. All other settings, LEDs remain.

Universal Safety Photo Eye UL MONITORED DEVICE

Universal Safety Photo Eye UL MONITORED DEVICE IRB-MON Universal Safety Photo Eye UL325-2016 MONITORED DEVICE Operating Instructions CAUTIONS AND WARNINGS This product is an accessory or part of a system. Always read and follow the manufacturer s instructions

More information

IRB-MON O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY PHOTOEYE U L M O N I T O R E D DEVICE

IRB-MON O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY PHOTOEYE U L M O N I T O R E D DEVICE O P E R A T I N G I N S T R U C T I O N S IRB-MON UNIVERSAL SAFETY PHOTOEYE U L 3 2 5-2 0 1 6 M O N I T O R E D DEVICE 4564 Johnston Parkway, Cleveland, Ohio 44128 P. 800 426 9912 F. 216 518 9884 Sales

More information

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L MONITORED DEVICE

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L MONITORED DEVICE O P E R A T I N G I N S T R U C T I O N S IRB-RET UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L 3 2 5-2 0 1 6 MONITORED DEVICE 4564 Johnston Parkway, Cleveland, Ohio 44128 P. 800 426 9912 F. 216 518 9884

More information

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L M O N I T O R E D DEVICE

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L M O N I T O R E D DEVICE O P E R A T I N G I N S T R U C T I O N S IRB-RET UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L 3 2 5-2 0 1 6 M O N I T O R E D DEVICE 4564 Johnston Parkway, Cleveland, Ohio 44128 P. 800 426 9912 F. 216

More information

IRB-MON UNIVERSAL SAFETY PHOTOEYE OPERATING UL MONITORED DEVICE

IRB-MON UNIVERSAL SAFETY PHOTOEYE OPERATING UL MONITORED DEVICE IRB-MON UNIVERSAL SAFETY PHOTOEYE OPERATING UL325-2016 MONITORED DEVICE 4564 Johnston Parkway, Cleveland, Ohio 44128 P. 800 426 9912 F. 216 518 9884 Sales Inquiries: salessupport@emxinc.com Technical Support:

More information

The Solution. Multi-Input Module IMPORTANT: READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION

The Solution. Multi-Input Module IMPORTANT: READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION The Solution Multi-Input Module INSTALLATION INSTRUCTIONS Model: MIM-62 IMPORTANT: READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION MIM-62 connects up to 6 monitored entrapment protection

More information

PC170 Control Box USER MANUAL 24V DC GEAR MOTOR FOR RESIDENTIAL

PC170 Control Box USER MANUAL 24V DC GEAR MOTOR FOR RESIDENTIAL PC170 Control Box 24V DC GEAR MOTOR FOR RESIDENTIAL USER MANUAL INDEX 1. CONTROL BOX 2. SETTING 2.1 SW1 DIP SWITCH SETTING 2.1.1 SLOWDOWN ADJUSTMENT (DIP 1. SLOW) 2.1.2 OVER-CURRENT ADJUSTMENT (DIP 2.OVER

More information

CB17 CONTROL SYSTEM USER MANUAL

CB17 CONTROL SYSTEM USER MANUAL CB1 CTROL SYSTEM USER MANUAL INDEX 1. CTROL BOX 2. CB1 CTORL PANEL LAYOUT AND WIRE CNECTI INDICATI 3. SYSTEM SET UP PROCEDURE 3.1 TRANSMITTER MEMORIZINGAND ERASING PROCESS 3.2 SYSTEM LEARNING PROCESS 3.3

More information

Tel Fax: Toll free:

Tel Fax: Toll free: ELECTRONIC CONTROL UNIT (cod. 2302B Series) for swing gates automation (Mini Tank Series) C5 Accessories power supply: 24V dc Max 200 ma T1 Trimmer regulation: Operating times Open pause time Leaf delay

More information

180 Series Keypad. Handbook. Revision 2.1

180 Series Keypad. Handbook. Revision 2.1 180 Series Keypad Handbook Revision 2.1 Revision History Revision 1.0 Initial release Revision 2.0 Major update with addition of 180-40 Added 180-40 to document and various headings Note regarding unique

More information

INSTALLATION INSTRUCTIONS 920 EntryCheck TM

INSTALLATION INSTRUCTIONS 920 EntryCheck TM 801 Avenida Acaso, Camarillo, Ca. 93012 (805) 494-0622 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS 920 EntryCheck TM The EntryCheck 920 Indoor/Outdoor Keypad is a surface-mount

More information

AS Keypad User Manual

AS Keypad User Manual AS Keypad User Manual Specifications Operating Voltage: 12~24 VAC/DC Current Draw: TBA Input: request-to-exit (for Relay 1) time out reed switch contact (for Relay 1) Output: Relay 1: N.O./N.C./Com. Output

More information

RFID/Digital Access Control Keypad

RFID/Digital Access Control Keypad R Luminous/ RFID/Digital Access Control Keypad Model:YK-368L-R Germany EMC tested FEATURES AND FUNCTIONS Simple Programming, Easy Operation 3-Operation Mode: ID Card Operation, User Code Operation, ID

More information

MODEL KP-100 ACCESS CONTROL DIGITAL KEYPAD OPERATING INSTRUCTIONS

MODEL KP-100 ACCESS CONTROL DIGITAL KEYPAD OPERATING INSTRUCTIONS MODEL KP-100 ACCESS CONTROL DIGITAL KEYPAD OPERATING INSTRUCTIONS Model KP-100 is a self-contained digital keypad. This keypad is suitable for residential, industrial, and commercial installations. It

More information

OPERATIONS MANUAL. n.form I/O Expander (RACK MOUNT) Document Number: Rev B

OPERATIONS MANUAL. n.form I/O Expander (RACK MOUNT) Document Number: Rev B OPERATIONS MANUAL n.form I/O Expander (RACK MOUNT) Document Number: 200-0009 Rev B table of contents INTRODUCTION FEATURES & CAPABILITIES 1 WIRING General I/O Configuring The System Using The System 4

More information

SOFTWARE VERSION 3.10

SOFTWARE VERSION 3.10 738PEP-03 SOFTWARE VERSION 3.10 HEXA PROGRAMMING: Addresses 000 to 043 and 300 to 527 are programmed using the Hexa Programming method. In this mode, you can enter any hexa-digit from 0-F where keys [1]

More information

INSTALLATION INSTRUCTIONS 921P EntryCheck TM

INSTALLATION INSTRUCTIONS 921P EntryCheck TM 80 Avenida Acaso, Camarillo, Ca. 90 (805) 494-06 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS 9P EntryCheck TM The EntryCheck 9P Indoor/Outdoor Keypad is a surface mount

More information

SmartLock Pro INSTALLATION MANUAL

SmartLock Pro INSTALLATION MANUAL SmartLock Pro INSTALLATI MANUAL July 2010 Cutting edge simplicity Table of Contents INTRODUCTI... 3 Diodes... 3 Power Supply Notice... 3 Terminal Strips and Cable... 4 SPECIFICATIS... 5 SMARTLOCK CTROLLER

More information

SmartLock Controller INSTALLATION MANUAL

SmartLock Controller INSTALLATION MANUAL SmartLock Controller INSTALLATI MANUAL November 2015 Table of Contents INTRODUCTI... 3 Diodes... 4 Terminal Strips and Cable... 5 SPECIFICATIS... 6 SMARTLOCK CTROLLER LAYOUT... 8 LED Indicators... 9 Mounting...

More information

THE BRIDGE. Make any Wiegand device wireless with the Sure-fi Bridge FEATURES. Technology

THE BRIDGE. Make any Wiegand device wireless with the Sure-fi Bridge FEATURES. Technology THE BRIDGE Make any Wiegand device wireless with the Surefi Bridge *Housing options sold separately. Keep your Wiegand system connected. Fix faulty Wiegand systems quickly and easily with our wireless

More information

User Manual. PCKeypad Wireless Keypad

User Manual. PCKeypad Wireless Keypad User Manual PCKeypad Wireless Keypad Description The PCKeypad is a wireless keypad with a PentaCODE transmitter built-in. It works with all of Elsema s PCR series receivers. The installer has the option

More information

User Guide Automatic Transfer Switch (ATS)

User Guide Automatic Transfer Switch (ATS) User Guide Automatic Transfer Switch (ATS) V.1.0 Table of Contents 1. Introduction... 2 2. Product Overview... 2 3. Important Safety Warnings... 3 4. Operation Indicators & Status... 3 5. Installation...

More information

Installation Instructions Installation Guidelines. Product Summary. For the maximum number of bus devices and touchpads per panel see Table 1.

Installation Instructions Installation Guidelines. Product Summary. For the maximum number of bus devices and touchpads per panel see Table 1. Document Number: 466-1632 Rev. B September 2000 Product Summary The ITI SuperBus 2000 2 x 20 LCD (liquid crystal display) Alphanumeric Touchpad gives you complete on-site system programming and operation

More information

212iL Rev. 1.1

212iL Rev. 1.1 212iL 1 International Electronics, Inc. 427 Turnpike Street Canton, Massachusetts 02021 212iL (illuminated Luxury) Keypad Single Unit Keypad- Control Installation Manual Features: 120 User Capability Illuminated

More information

EA500. Installation Instructions Transponder

EA500. Installation Instructions Transponder EA500 EN Installation Instructions Transponder EA500 Installation Instructions 1.0 Overview EN 2 1.0 Overview The EA500 Transponder is the Security Escort module that provides communications between the

More information

INSTALLATION INSTRUCTIONS 920P EntryCheck TM

INSTALLATION INSTRUCTIONS 920P EntryCheck TM 801 Avenida Acaso, Camarillo, Ca. 93012 (805) 494-0622 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS 920P EntryCheck TM The EntryCheck 920P Indoor/Outdoor Keypad is a surface-mount

More information

425D. Control Panel. Instructions. (800)

425D. Control Panel. Instructions. (800) 425D Control Panel Instructions Figure 13. Wiring detail of the 412 operator to the 425D Connecting the Operator(s) If your gate system has one operator, connect the black and white wires from your operator

More information

Connecting a Cisco Reader Module

Connecting a Cisco Reader Module CHAPTER 3 Overview The optional Cisco Reader Module (Figure 3-1) is similar to the Cisco Physical Access Gateway, providing the same ports for Weigand readers and other input and output devices. The Cisco

More information

Eclipse MCi. Variable Speed Drive Controller with Eclipse Operating System (EOS) 3rd Edition. VSD kits suitable for motors ranging from 0.4 to 2.

Eclipse MCi. Variable Speed Drive Controller with Eclipse Operating System (EOS) 3rd Edition. VSD kits suitable for motors ranging from 0.4 to 2. 3rd Edition Variable Speed Drive Controller with Eclipse Operating System (EOS) Eclipse MCi VSD kits suitable for motors ranging from 0.4 to 2.2 kw www.elsema.com Controller with Eclipse Operating System

More information

Quick Start Installation Guide

Quick Start Installation Guide apc/l Quick Start Installation Guide Version A2 Document Part Number UM-201 May 2010 OVERVIEW The apc/l is an intelligent access control and alarm monitoring control panel which serves as a basic building

More information

G2M Control Board Installation and Operations Manual

G2M Control Board Installation and Operations Manual BYAN SYSTEM, INC. 413 LINDEN LUSK, WY 82225 (800) 223-2926 G2M Control Board Installation and Operations Manual Specifications Power supply Motor Power Consumption Electric Lock Output Accessory Power

More information

Quick Start Installation Guide

Quick Start Installation Guide istar Pro Quick Start Installation Guide Version B0 Part Number UM-069 January 2005 OVERVIEW This guide defines all of the commonly used connection methods to the istar Pro. It outlines how to wire readers

More information

Installation & User Manual

Installation & User Manual Contents Installation Instructions 3 Installation Diagrams 4 System Overview 6 Wiring Diagrams 8 Network Diagrams 9 Operation Instructions Fingerprint Enrollment 12 21 Wi-Enterprise Controller www.transmittersolutionssmart.com

More information

900-4RL Option Board. Refer to installation instructions for compatible supply models - PS902, PS904, PS906, and PS914. Note

900-4RL Option Board. Refer to installation instructions for compatible supply models - PS902, PS904, PS906, and PS914. Note *44487080* 44487080 DANGER To avoid risk of electric shock, turn off AC power to power supply before installing or wiring option board. 900- Option Board Installation Instructions 900- Specifications Inputs

More information

Installation & User Manual V2.08

Installation & User Manual V2.08 YOUR SECURITY IS OUR PRIORITY Other products from GSD Contents Installation Instructions Installation Diagrams System Overview Wiring Diagrams Network Diagrams Operation Instructions Fingerprint Enrollment

More information

Beacon Power Supply Operating and Installation Instruction Manual

Beacon Power Supply Operating and Installation Instruction Manual Beacon Power Supply Operating and Installation Instruction Manual Model: BNx000 Page 1 of 27 I. Warnings and Notices I. WARNING - To reduce the risk of fire or electric shock, do not expose this product

More information

9212i INSTALLATION. Stand-Alone Keypad. Instructions

9212i INSTALLATION. Stand-Alone Keypad. Instructions INSTALLATION 9212i Stand-Alone Keypad Instructions Features: 4 Independent Outputs 4 Independent Timers All Outputs Assignable by Code On board 5 Amp Form C Relay 120 Users Remote Triggering Input Keypad

More information

Innovative Electronics for a Changing World. Charge Smart R1 MPPT 12V/24V Auto detect Mains and Solar Battery charger with Remote Network Monitoring

Innovative Electronics for a Changing World. Charge Smart R1 MPPT 12V/24V Auto detect Mains and Solar Battery charger with Remote Network Monitoring Innovative Electronics for a Changing World Charge Smart R1 MPPT 12V/24V Auto detect Mains and Solar Battery charger with Remote Network Monitoring INDEX 1. SYSTEM DESCRIPTION 2. SYSTEM WIRING 3. SYSTEM

More information

721EX Access Controller Installation

721EX Access Controller Installation 721EX Access Controller Installation 721EX Controller Standalone Controller Specifications Max Card Capacity: 3000 What is included in the box B-Id 721EX controller board RS485/Serial converter USB/Serial

More information

SPX-5000 Series. Operations Manual. Suprex Reader Extender - RF Wireless Interface. RPT GHz Repeater. SPX GHz

SPX-5000 Series. Operations Manual. Suprex Reader Extender - RF Wireless Interface. RPT GHz Repeater. SPX GHz SPX-5000 Series Operations Manual Suprex Reader Extender - RF Wireless Interface SPX-5601 2.4GHz RPT-5651 2.4GHz Repeater SPX-5521 900 Mhz IOX-7621 2.4GHz EXP-2000 SPX-6601 2.4GHz SPX-5000_MAN_082112 This

More information

CA-A480-A Elevator Controller. Reference & Installation Manual

CA-A480-A Elevator Controller. Reference & Installation Manual CA-A480-A Elevator Controller Reference & Installation Manual TABLE OF CONTENTS INTRODUCTION.................................................................. 4 Introduction.............................................................................................

More information

Ellard Product Instructions

Ellard Product Instructions Ellard Product Instructions Motor Controller - V3D Maxi Stock Code Description Roundthorne Ind Est Floats Road Wythenshawe Manchester M23 9WB Tel: +44 (0) 161 945 4561 Fax: +44 (0) 161 945 4566 Iss: 1

More information

Secrure door control and I/O expansion. Installation Guide. (ver 1.0)

Secrure door control and I/O expansion. Installation Guide. (ver 1.0) Secrure door control and I/O expansion Installation Guide (ver 1.0) www.supremainc.com Contents Product Contents 3 Front Panel Description 4 Rear Panel Description 5 Connectors for External Interfaces

More information

Connecting a Cisco Output Module

Connecting a Cisco Output Module CHAPTER 5 Overview The optional Cisco Output Module (Figure 5-1) is attached to a Cisco Physical Access Gateway or Cisco Reader Module to provide additional connections for up to 8 outputs, each of which

More information

Wireless Gate Entry Intercom/Keypad

Wireless Gate Entry Intercom/Keypad IMPORTANT: Allow the intercom base unit s battery to charge for 12 hours before using the system for the first time. See page 6 for details. Wireless Gate Entry Intercom/Keypad Instructions for Wireless

More information

QCPort Cover Control Trouble Shooting Guide

QCPort Cover Control Trouble Shooting Guide QCPort Cover Control Trouble Shooting Guide Technical Document Feb. 2006 Page 1 of 14 QCPort Cover Control Description Door Defeater Address/Options Bucket Latch Breaker Actuator Hasp Lock Keypad Overlay

More information

Modules Programming Guide. paradox.com

Modules Programming Guide. paradox.com Keypad Modules Annunciator Module Motion Detector Modules Zone Expansion Modules Access Control Module Voice Assisted Modules Accessory Modules Integration Module Internet Module Modules Programming Guide

More information

Blue Point Engineering

Blue Point Engineering Blue Point Engineering SV203 Interface Overview Overview Sensors Light Sensor Motion Sensor Joystick Computer USB PORT Technical Pointing the Way to Solutions! T http://www.bpesolutions.com Animatronic

More information

Click Save to return to the main Setup screen.

Click Save to return to the main Setup screen. ON-SITE Setup Guide Thank you for purchasing the ON-SITE. This guide will assist you in the setup of the system. You can call for FREE technical support to get help anytime at 757-258-0910. Please note,

More information

Control Panel for Swing Gates. Model: CP-12 / January 2007

Control Panel for Swing Gates. Model: CP-12 / January 2007 Control Panel for Swing Gates Model: CP-12 / January 2007 INDEX Page 1- INTRODUCTION 3 1.1 1.2 Electrical and mechanical specification General Features 2- INSTALLATION AND SETUP 2.1.1 Installation of actuator

More information

Digital Keypad Introduction

Digital Keypad  Introduction K2 Digital Keypad Introduction The K02 uses the latest microprocessor technology to operate door strikes and security systems that require a momentary (timed) or latching dry contact closure. All programming

More information

Suprex Fiber Optic. Reader-Extender SPX-7400 SPX Product Manual. Reader-Extender. Manual. SPX-7400 Series EXP Suprex_FiberOptic_MAN_170502

Suprex Fiber Optic. Reader-Extender SPX-7400 SPX Product Manual. Reader-Extender. Manual. SPX-7400 Series EXP Suprex_FiberOptic_MAN_170502 Suprex Fiber Optic Reader-Extender SPX-7400 SPX-7410 Product Manual Reader-Extender Manual SPX-7400 Series EXP-2000 Suprex_FiberOptic_MAN_170502 Cypress Integration Solutions 30+ Years of Access Control

More information

e-ask electronic Access Security Keyless-entry OEM / Dealer / Installer Cargo Lock / Unlock Version Installation & Instructions (UM04 ~ )

e-ask electronic Access Security Keyless-entry OEM / Dealer / Installer Cargo Lock / Unlock Version Installation & Instructions (UM04 ~ ) e-ask electronic Access Security Keyless-entry OEM / Dealer / Installer Cargo Lock / Unlock Version Installation & Instructions (UM04 ~ 18990-04) Table of Contents Introduction... 1 e-fob Operation and

More information

C5S120 Installation and Connection Guide

C5S120 Installation and Connection Guide C5S120 Installation and Connection Guide Version: V1.1 1. Cautions Please note the following cautions. Mis-operation may lead to personal injury or equipment failure: 1) Do not energize the system before

More information

VISTA 12a / 48a TECHNICAL TRAINING. The Best in Security plus Everyday Convenience & Control

VISTA 12a / 48a TECHNICAL TRAINING. The Best in Security plus Everyday Convenience & Control VISTA 12a / 48a TECHNICAL TRAINING The Best in Security plus Everyday Convenience & Control Version #.007 7th June 2005 VISTA 12a / 48a Training Guide Index 1. Vista Family Features....... p. 3 2. Wiring

More information

FRICK QUANTUM ACUair CONTROL PANEL VERSION 2.1x

FRICK QUANTUM ACUair CONTROL PANEL VERSION 2.1x S90-500 M/JULY 2002 File: SERVICE MANUAL - SECTION 90 Replaces: NOTHING (New Information) Dist: 3, 3a, 3b, 3c FRICK QUANTUM ACUair CONTROL PANEL VERSION 2.1x S90-500 M FRICK QUANTUM ACUair CONTROL PANEL

More information

SPX-7400_SPX-7410_MAN_161028

SPX-7400_SPX-7410_MAN_161028 Suprex Fiber Optic SPX-7400 & SPX-7410 Suprex Reader-Extender Data Sheet SPX-7400 Series EXP-2000 SPX-7400_SPX-7410_MAN_161028 1 Cypress Suprex SPX-7400 & SPX-7410 Overview The Suprex Fiber Optic SPX-7400

More information

DG-800 Stand-Alone Proximity Reader Instruction Manual

DG-800 Stand-Alone Proximity Reader Instruction Manual DG-800 Stand-Alone Proximity Reader Instruction Manual I. Features 1. Memory volume up to 1000+10 proximity cards/tokens and PINs with the programming time up to 0.5 seconds. 2. Access modes: a. Only Proximity

More information

Wireless Key fob, Key pad & Receiver Range

Wireless Key fob, Key pad & Receiver Range Wireless Key fob, Key pad & Receiver Range 4Ch Wireless Receiver 4x Voltage Free relay outputs (NO + NC) 100m Transmission range Multiple user codes 2 Channel wireless control Clear hinge up lid 12V DC

More information

Quick Start Installation Guide

Quick Start Installation Guide RM-DCM-2 Quick Start Installation Guide Version G0 Document Part Number UM-215 May 2010 OVERVIEW The RM-DCM-2 is a UL294 Listed and UL1076 Listed door control module that includes the RM-4E Reader Module

More information

GV-AS200 Controller. Hardware Installation Guide

GV-AS200 Controller. Hardware Installation Guide GV-AS200 Controller Hardware Installation Guide Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. 2008 GeoVision, Inc.

More information

1 Description. 2 Specifications. Product Installation Document. Honeywell 12 Clintonville Road Northford, CT

1 Description. 2 Specifications. Product Installation Document. Honeywell 12 Clintonville Road Northford, CT Honeywell 12 Clintonville Road Northford, CT 06472 http://www.honeywellpower.com HP600ULACM4CB HP600ULACM8CB Access Control Power Supply/Charger with Power Distribution Controller PN 52395:A 1/05/06 ECN

More information

FVT/FVR20D2I1C4E INSTALLATION AND OPERATION MANUAL

FVT/FVR20D2I1C4E INSTALLATION AND OPERATION MANUAL 2-CHANNEL 10-BIT DIGITALLY ENCODED VIDEO + 2 BI-DIRECTIONAL DATA + AIPHONE INTERCOM + 4 CONTACT CLOSURE + 100MB ETHERNET + REDUNDANT POINT-TO-POINT DUAL SFP OPTICAL PORTS The series utilize 10-bit digital

More information

Suprex RF Series CYPRESS. Operations Manual. Suprex Reader Extender - RF Wireless Interface EXP SPX Mhz SPX-5521_MAN_0316

Suprex RF Series CYPRESS. Operations Manual. Suprex Reader Extender - RF Wireless Interface EXP SPX Mhz SPX-5521_MAN_0316 CYPRESS Suprex RF Series Operations Manual Suprex Reader Extender - RF Wireless Interface EXP-2000 SPX-5521 900 Mhz SPX-5521_MAN_0316 Cypress Suprex SPX-5521 Series Overview This manual covers the operation

More information

ADDENDUM FOR 20, 27, & 28 OPTIONS

ADDENDUM FOR 20, 27, & 28 OPTIONS ADDENDUM FOR 20, OPTIONS GENERAL The 20, 27, and 28 option provides for an alarm contact OR an AC transfer switch on EXELTECH XP Series inverters. The alarm relay monitors the inverter s AC output and

More information

Comfort, the Intelligent Home System. Comfort Fingerprint Reader Interface FPR01

Comfort, the Intelligent Home System. Comfort Fingerprint Reader Interface FPR01 Comfort, the Intelligent Home System Comfort Fingerprint Reader Interface FPR01 Introduction to the Comfort Fingerprint Reader Interface... 1 Specifications... 2 Equipment... 2 Settings... 2 Connections...

More information

A0/A1 Controller Assembly Operation/Installation Manual READ AND FOLLOW ALL SAFETY INSTRUCTIONS

A0/A1 Controller Assembly Operation/Installation Manual READ AND FOLLOW ALL SAFETY INSTRUCTIONS Document Number: 9100-127-2301-99 Release Date: 2/2/15 A0/A1 Controller Assembly Operation/Installation Manual READ AND FOLLOW ALL SAFETY INSTRUCTIONS DO NOT let any supply cords touch hot surfaces higher

More information

Trouble Shooting. Symptoms: Gate Access Control Computer connected to the Facility Computer

Trouble Shooting. Symptoms: Gate Access Control Computer connected to the Facility Computer Trouble Shooting Symptoms: Gate Access Control Computer connected to the Facility Computer "Unable to read from controller (CTS lost)" error message on computer screen Do Power checks Do controller (computer

More information

RACK-220 CHASSIS USER S MANUAL

RACK-220 CHASSIS USER S MANUAL RACK-220 CHASSIS USER S MANUAL 1 Copyright Notice This document and product is copyrighted, Jun 1999, by ICP Electronics Inc. All rights are reserved. No part of this manual may be reproduced, copied,

More information

Wiring Guide. EP.NMiNi 2. Version 1.04 Last Updated:

Wiring Guide. EP.NMiNi 2. Version 1.04 Last Updated: Wiring Guide EP.NMiNi 2 Version 1.04 Last Updated: 31-01-2013 Before you begin Technical Support If you cannot find the answer to your question in this manual or in the Help files, we recommend you contact

More information

Torque Control Verifier

Torque Control Verifier Torque Control Verifier Instruction Manual Revision 1.2 September 2002 Please Read and Understand Instructions Before Attempting Installation Torque Control Verifier Contents: Quick Start Introduction

More information

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS MAINTENANCE MANUAL EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS SPECIFICATIONS*... 2 INTRODUCTION... 3 DESCRIPTION...

More information

Intelligent Devices IDI 1100 Series Technical Manual

Intelligent Devices IDI 1100 Series Technical Manual Intelligent Devices IDI 1100 Series 4411 Suwanee Dam Road, Suite 510 Suwanee, GA 30024 T: (770) 831-3370 support@intelligentdevicesinc.com Copyright 2011, Intelligent Devices, Inc. All Rights Reserved

More information

Suprex RS-485 SPX-7500 Wired Reader-Extender

Suprex RS-485 SPX-7500 Wired Reader-Extender Suprex RS-485 SPX-7500 Wired Reader-Extender Product Manual SPX-7500_MAN_181206 Cypress Integration Solutions 35 Years of Access Control Ingenuity CypressIntegration.com 2018 Cypress Computer Systems 1778

More information

AirTest Model CN9000 Series Sensor Controller

AirTest Model CN9000 Series Sensor Controller AirTest Model CN9000 Series Sensor Controller AirTest Model CN9000 Series Sensor Controller THEORY OF OPERATION A basic CN9000 configuration consists of Input/Process/Display combination modules, a 3 relay

More information

E600 VX01 Installation guide

E600 VX01 Installation guide E600 VX01 Installation guide illuminfx Dimensions 2007 Viso Systems ApS, Denmark All rights reserved. No part of this manual may be reproduced, in any form or by any means, without permission in writing

More information

DVR6828 Full version Video Recording Module For Vehicle

DVR6828 Full version Video Recording Module For Vehicle DVR6828 Full version Video Recording Module For Vehicle Description This digital video recorder is specially designed for vehicle surveillance. It overcomes machine hang and files corruption issues, with

More information

Telephone Line Monitor USER GUIDE

Telephone Line Monitor USER GUIDE Telephone Line Monitor USER GUIDE For Technical Assistance call the Manufacturers direct Ph 800 530 8645 8AM - 5PM West Coast Pacific Time NATCOMM USA LLC Responsible Supplier Code NC OPERATION Our Telephone

More information

PentaTimer Receiver Two Channels, 433MHz Penta Receiver with Time Clock Functions

PentaTimer Receiver Two Channels, 433MHz Penta Receiver with Time Clock Functions PentaTimer Receiver Two Channels, 433MHz Penta Receiver with Time Clock Functions ELSEMA Features Supply voltage 240VAC (also available in 110-120VAC supply for international markets) Din rail mountable

More information

Obsolete. BR Series USB Tech Kit. B l u e R i d g e. T e c h n o l o g i e s. User Guide. Page 1. Hardware and Software Instructions

Obsolete. BR Series USB Tech Kit. B l u e R i d g e. T e c h n o l o g i e s. User Guide. Page 1. Hardware and Software Instructions Hardware and Software Instructions Page 1 Attention Page 2 This section serves as a notice of the immediate or potential dangers involved when working with the equipment described throughout this manual.

More information

Quick Guide. Extra Communication Card

Quick Guide. Extra Communication Card Quick Guide Extra Communication Card Uninterruptible Power Supply System Version: 1.0 Table of Contents 1. Product Outlook... 3 2. Product Introduction... 3 2.2. RS232 port... 4 2.3. COMM. Slot... 4 2.4.

More information

Rev Cutler-Hammer Smart Breaker Panel Control Manual

Rev Cutler-Hammer Smart Breaker Panel Control Manual 026-70 Rev 0 6-0-03 Cutler-Hammer Smart Breaker Panel Control Manual 640 Airport Road, Suite 04 Kennesaw, GA 3044 Phone: (770) 425-2724 Fax: (770) 425-939 ALL RIGHTS RESERVED. The information contained

More information

TBox-Radio & WIRC photocell User manual

TBox-Radio & WIRC photocell User manual Kit TBox-Radio & WIRC photocells 1. TBox-Radio 1.1 Appearance Radio antenna 2 x Photocells Jack Inputs Ext GPS antenna (TBox-4x only) 4 Group / ID LEDs Radio Config button 2 inputs LEDs Sync Jack RS232

More information

Quick Installation Manual

Quick Installation Manual Quick Installation Manual Please Note: Full Technical guide is located on the DVD if this is your first time installing a Hartmann Controls Access Control System. It is strongly recommended you review

More information

Access Control System - Installation Guide

Access Control System - Installation Guide ACS Access Control System - Installation Guide The Remotelock ACS is a cloud based access management system that integrates external door controllers with internal stand-alone Wi-Fi locks for a complete

More information

AC-115 Compact Networked Single-Door Controller Hardware Installation and Programming

AC-115 Compact Networked Single-Door Controller Hardware Installation and Programming AC-115 Compact Networked Single- Controller Hardware Installation and Programming Copyright 2013 by Rosslare. All rights reserved. This manual and the information contained herein are proprietary to REL,

More information

Installation and Operation

Installation and Operation Installation and Operation Joystick System Controller WDS-3510CT CONTENTS Contents General Information Function Description..... 3 Scope of Delivery.. 3 Safety Precautions....... 4 Connection and Configuration

More information

Control board for electromechanical gearmotors HERMES

Control board for electromechanical gearmotors HERMES Control board for electromechanical gearmotors HERMES 1 Attention! The present user manual is designed for personnel skilled in installation, not for the final user; the electrician is then due to inform

More information

Installing Sentor. Hardware Installation

Installing Sentor. Hardware Installation Remote base site monitoring and control Installing Sentor Hardware Installation Copyright 2000 Sentor Monitoring Systems Pty Ltd Contents: 1 Introduction... 1 2 Sentor GUI... 2 3 ST3000 Controller... 3

More information

Zartek. CDP-808 Two Button Wireless Intercom Installers Manual

Zartek. CDP-808 Two Button Wireless Intercom Installers Manual Zartek CDP-808 Two Button Wireless Intercom Installers Manual ZA-614 Two Button Gate station including power supply, relay board and external antenna ZA-613 Handsets with charger ZA-613-E Handsets with

More information

Model: EP.L3800. Wiring Guide EP.L3800. Version 1.03 Last Updated:

Model: EP.L3800. Wiring Guide EP.L3800. Version 1.03 Last Updated: Wiring Guide EP.L3800 Version 1.03 Last Updated: 13-10-2014 1 Note: L3800 is the serial enabled lift controller. L3800 will ship with a HIO board in a package which can cater up to 8 floors. It can connect

More information

DC3IOB Revision User Guide Updated 3/29/10. Overview

DC3IOB Revision User Guide Updated 3/29/10. Overview Revision 080910 User Guide Updated 3/29/10 Overview The is a three axis DC brush motor drive with an integrated PLC. A range of motor drive currents are selectable with jumper blocks. The integrated PLC

More information

6222 Two Door Module Technical Operations Manual

6222 Two Door Module Technical Operations Manual 6222 Two Door Module Technical Operations Manual TABLE OF CONTENTS Specifications...3 Overview...4 Operations...5 Custom Access Mode...5 Standard Access Mode...5 Offline Access Mode...5 Offline Memory...5

More information

Connection and Operation (Built-In Controller Package)

Connection and Operation (Built-In Controller Package) Stepping Motors Connection and Operation (Built-In Controller Package) Names and Functions of Parts Motor Connector 1 1 Signal Monitor Display LED Indicators Indication Color Function When Activated OPERATION

More information

Suprex Ethernet SPX-7200 Ethernet Reader-Extender

Suprex Ethernet SPX-7200 Ethernet Reader-Extender Suprex Ethernet SPX-7200 Ethernet Reader-Extender Product Manual 1 SPX-7200_MAN_181206 Cypress Integration Solutions 35 Years of Access Control Ingenuity CypressIntegration.com 2018 Cypress Computer Systems

More information

Modules Programming Guide

Modules Programming Guide Modules Programming Guide Programming Methods The modules can be programmed using the following methods: 1) Through the WinLoad Security Management Software. The modules can be programmed at 19,200 baud

More information

istar Pro Installation Guide

istar Pro Installation Guide istar Pro Installation Guide UM-241 Version A1 October 2010 istar Pro Installation Quick Start Guide System Components The istar Pro hardware components consist of: General Controller Module (GCM) A general

More information

Pro-Star AVW200 Installation and Operation Manual Protel, Inc. ALL RIGHTS RESERVED AVW200HM01.1

Pro-Star AVW200 Installation and Operation Manual Protel, Inc. ALL RIGHTS RESERVED AVW200HM01.1 Pro-Star AVW200 Installation and Operation Manual 2005 Protel, Inc. ALL RIGHTS RESERVED AVW200 Installation and Operation Manual Revision History Revision Date Description of Changes AVW200HM01.0 12/05

More information

HYDROTHUNDER WIRING & CIRCUIT INFORMATION C H A P T E R F I V E

HYDROTHUNDER WIRING & CIRCUIT INFORMATION C H A P T E R F I V E HYDROTHUNDER C H A P T E R F I V E WIRING & CIRCUIT INFORMATION WARNING: Failure to reconnect all ground wires or to replace metal shields and covers with each mounting screw installed and securely tightened

More information

VANDAL RESISTANT BACK-LIT WEATHERPROOF ACCESS CONTROL KEYPAD

VANDAL RESISTANT BACK-LIT WEATHERPROOF ACCESS CONTROL KEYPAD VANDAL RESISTANT BACK-LIT WEATHERPROOF ACCESS CONTROL KEYPAD Post Mount Keypad Programming & Installation Manual 1. Connect Power 12V DC to 24V AC/DC to terminals (+) and (-) Post Mount Keypad Quick Start

More information