1 By billion new middle class consumers will add $8T to consumer spending Increased Demand on Industrial Production GLOBAL POPULATION TRENDS INCREASE DEMAND FOR Manufacturing Resources Infrastructure EMERGING MARKET CONSUMERISM 30% 100% More Water More Vehicles 80% More Steel 50% More Energy RESOURCE PRODUCTIVITY INVESTMENT $1T Annually Source: McKinsey Copyright 2014 Rockwell Automation, Inc. All Rights Reserved. 1
2 Connected Enterprise Delivers Optimized for Rapid Value Creation Supply Chain Integration Collaborative, Demand Driven Compliant and Sustainable $ Faster Time to Market COMPANY CONFIDENTIAL - Internal Use Only Lower Total Cost of Ownership Improved Asset Utilization Enterprise Risk Management Copyright 2012 Rockwell Automation, Inc. All rights reserved.
3 <14% PRODUCTION In the U.S. have tied their facilities to the enterprise network. SOURCE: Industry Week Copyright 2014 Rockwell Automation, Inc. All Rights Reserved.
4 Energy Information Architecture FT EnergyMetrix Server FT VantagePoint Server Other Business Servers Engineering Workstations Manager Workstations Wide Area Network Local Area Network 3 rd Party Power Monitors OPC Server 4-20ma Discrete A-B Power Monitors 3 rd Party PLCs A-B PLCs & Sensors Water, Air, Gas, Electricity Steam, Instrument Air, Process Air, Fuel, Nitrogen and Effluent Measurements PUBLIC INFORMATION 4 Copyright 2013 Rockwell Automation, Inc. All Rights Reserved.
5 PUBLIC INFORMATION Copyright 2013 Rockwell Automation, Inc. All Rights Reserved. 5 Not Just Electricity 4-20ma Discrete Logix controllers can also collect energy data from digital or analog outputs of a variety of energy meters or transmitters such as water, air, gas, steam, electric, steam and other fuels
6 PUBLIC INFORMATION Copyright 2013 Rockwell Automation, Inc. All Rights Reserved. Why Manage Industrial Energy? The Industrial sector consumes more energy than any other. Total Energy Consumption by Sector Top Market Pressures Source: US Energy Information Agency: Aberdeen Group Report 2011 Rockwell Automation is an Industry Leader in helping customers optimize their production operations to reduce cost
7 PUBLIC INFORMATION Copyright 2013 Rockwell Automation, Inc. All Rights Reserved. Energy Trends in the Industrial Space Past Operations pays the bill every month Energy as overhead Energy programs come secondary to production Metering for billing only Amortized across all BU s Present Internal team addresses pricing & low hanging fruit Use consultants for domain areas Expressed as $/Square Foot Metering and automated control of major equipment Broken down by dept/shifts Future Realtime models determine optimum production and purchasing Expressed as $/SKU or BTU/unit Metering and control plant-wide Energy as Cost of Goods Sold (BOM) to determine true margins of each product $0.03/GAL $7.23/sqft $0.05/mL 0.23 BTU/UNIT $0.0012/SKU
8 PUBLIC INFORMATION Copyright 2013 Rockwell Automation, Inc. All Rights Reserved. The IT Floor? Most Factory Automation is Left Unprotected And Can Represent as Much as 30% Of A Plant s Unplanned Downtime There is More Micro-processing Power on the Factory Floor Than in the Average IT Room
9 PUBLIC INFORMATION Copyright 2013 Rockwell Automation, Inc. All Rights Reserved. 9 Understanding Energy Reduce Consumption Power-down equipment when not in use Install more energy-efficient equipment Repair/Replace broken equipment Reduce Demand Stagger startups Perform startups during off-peak hours Reduce frequency of startups Correct Power Factor Install capacitor banks to balance load Reduce operation of inductive loads Reduce Downtime Optimize preventative maintenance Diagnose power quality issues impacting equipment health and grid stability
10 PUBLIC INFORMATION Copyright 2013 Rockwell Automation, Inc. All Rights Reserved. Impact on Common Industrial Components Relays Drop Out Controllers Drop Out 00 Source: IEEE Std
11 Energy Management - is a Closed loop Process Adjust Control + Monitor Analyze Control PUBLIC INFORMATION Electrical Systems Distribution Monitoring Load Profiling Power Quality Mechanical Systems HVAC Pumps Motors Energy Costs Monthly Bills Price Forecasts Utility Tariffs Time of Use Demand Charges Rate Options Poor Power Factor Process Efficiencies Cost Allocation Energy Per Unit Solution Options Energy Strategy Energy Sources Solution ROI Demand Demand Management System Emergency Load Shedding Peak Shaving Consumption Boiler/Chiller Control/Optimization Efficient Motors & Gears Variable Frequency Drives Procurement On-Site Generation Real Time Purchasing Load Shaping Copyright 2013 Rockwell Automation, Inc. All Rights Reserved.
12 PUBLIC INFORMATION Copyright 2013 Rockwell Automation, Inc. All Rights Reserved. 12 Rockwell Automation Power Quality Monitoring I-Sense PowerMonitor 5000 Information I-Grid FactoryTalk Energy Metrix Interruption UPS Portfolio Sag DySC Dynamic Sag Corrector Portfolio Surge / Noise Surge Filters Rockwell Automation has a portfolio of products to identify and mitigate power quality events
13 PUBLIC INFORMATION Copyright 2014 Rockwell Automation, Inc. All Rights Reserved. 13 Intelligent Motor Control portfolio Energy information at the device level Scalable energy monitoring capabilities Monitor power consumption across the network Correlate energy consumption with operational data to track equipment performance LV E300 Overload Relay Full Voltage starters --Fixed speed - Intelligent overload relays Soft starters -Reduced voltage -Fixed speed Variable Frequency Drives - Variable speed Motor Control Centers -Single assembly for multiple starters
14 Copyright 2012 Rockwell Automation, Inc. All rights reserved. 14 Can your overload relay reduce your electric bill? The energy consumed by electric motors in a manufacturing facility is one of the main contributors to the total electrical cost for manufacturers. However, many manufacturers do not realize that these same electronic overload relays provide some form of power based diagnostic information that can provide a manufacturing facility with insightful information about how to efficiently use electrical energy and lower their overall electric costs
15 Copyright 2012 Rockwell Automation, Inc. All rights reserved. 15 Can your overload relay reduce your electric bill? If network based electronic overload relays already exist in a facility, they can also be used to monitor energy usage at the individual motor loads. Using a historical data collection system, users can monitor current usage (at a minimum) for the respective electric motor that the overload is protecting.
16 PUBLIC INFORMATION Copyright 2013 Rockwell Automation, Inc. All Rights Reserved. 16 i-sense Voltage Monitoring Easy to use and install Connected to cloud-based power grid monitoring network Accessible from anywhere, on any device Near instant notifications via SMS or No software to install or configure Corroboration notifications: transmission event or local distribution Simple, permanent voltage sag detection and monitoring
17 PUBLIC INFORMATION Copyright 2013 Rockwell Automation, Inc. All Rights Reserved. Energy Intelligence Aligning energy usage with production data Energy and production data Context Information Decision IMPROVED decision making Production Software People
18 Copyright 2012 Rockwell Automation, Inc. All rights reserved. 18 DySC (Dynamic Sag Corrector) DySC (pronounced Disk ) Battery-free UPS Up to 5 seconds of ride through U.S. and International voltages available Scalable solution MiniDySC (single-phase; 2-50 Amp) ProDySC (3-phase; A) MegaDySC (3-phase; Amp)
19 Copyright 2013 Rockwell Automation, Inc. All Rights Reserved. Effective Energy Management You Can t Manage What You Don t Measure Turbine Refrigerator Mixer Chiller Boiler 1. Know what you are using, (who s using it), and what that usage is over time. 2. Understand why you are using it. 3. Understand how energy consumption is contributing to your costs (e.g. peak demand).
20 Copyright 2013 Rockwell Automation, Inc. All Rights Reserved. 20 Energy Intelligence Product Overview Trend Excel Reports Demand vs. consumption charts 48hr dashboard Dashboard Customized examples Tabular reports Demand charts Actionable Information Real time access to Power Meters Demand and consumption reporting Advanced billing capabilities Power Quality reporting and analyses
21 PUBLIC INFORMATION Copyright 2013 Rockwell Automation, Inc. All Rights Reserved. 21 How to Differentiate Power Monitors Measurement Capacity Consumption / Demand Power Factor Power Quality: Sag/Swell Detection, Harmonics, Transients Waveform Capture Accuracy Accuracy as a percentage; Revenue Grade Accuracy Networking / Communication EtherNet/IP, ControlNet, DeviceNet, Serial Internal Data Logging Capacity Record activity without external data logging software
22 PUBLIC INFORMATION Copyright 2013 Rockwell Automation, Inc. All Rights Reserved. 22 How to Differentiate Power Monitors Embedded Inputs / Outputs Status Inputs: Log data from external meters via pulse inputs Relay Outputs: Direct control over connected devices KYZ Outputs: Standardized pulse output for electrical metering Setpoint Control Activate outputs based on internal metering setpoints Example: Turn off Relay 1 if power consumption exceeds 3 kwh CIP Energy Support CIP Energy: Common Industrial Protocol for Energy Data
23 PUBLIC INFORMATION Copyright 2013 Rockwell Automation, Inc. All Rights Reserved. 23 PowerMonitor 1000 Metering Consumption (kwh) Demand (kw)* Power Factor (%)* Communication EtherNet/IP Serial * Optional Key Features Embedded web page for real-time data and configuration DIN-rail mounted Diagnostic utility for incorrect wiring Two status inputs for external metering (Water, Air, Gas, etc.) Integrated display for configuration Sub-Process Meter
24 PUBLIC INFORMATION Copyright 2013 Rockwell Automation, Inc. All Rights Reserved. 24 PowerMonitor 500 Metering Consumption (kwh) Demand (kw) Power Factor (%) Communication EtherNet/IP Serial Key Features Door mounted Large backlit display for real-time monitoring Fully configurable by touchkeys and display Configurable alarming Integration with FactoryTalk EnergyMetrix Integrated analog or digital outputs (optional) At-Process Meter
25 PUBLIC INFORMATION Copyright 2013 Rockwell Automation, Inc. All Rights Reserved. 25 PowerMonitor 5000 Metering Consumption (kwh) Demand (kw) Power Factor (%) Sag/Swell, Flicker Harmonics (n=127) Waveform Capture Communication EtherNet/IP Key Features Logix Add-On Profile (v22) Virtual correction of wiring errors Revenue Grade Accuracy (Class 0.2) IEEE 1588 Time Synchronization CIP Energy Support Status Inputs / Relay Outputs ControlFLASH Upgradable Feed Meter
26 PUBLIC INFORMATION Copyright 2014 Rockwell Automation, Inc. All Rights Reserved. What can we help you achieve? Gain accurate visibility of energy consumption of your assets Compare energy efficiency across plants and assets with normalized data Analyze energy usage trends compared to historical patterns and forecasts Trigger alerts from unexpected deviations Prioritize actions and investments based on financial and operational parameters Rockwell Automation is an industry leader in helping customers optimize their production operations to reduce costs
27 PUBLIC INFORMATION Copyright 2014 Rockwell Automation, Inc. All Rights Reserved. 27 What can Rockwell Automation services do for you? Site surveys and site power analyses The basic objectives of surveys and site power analyses are as follows: Determine the soundness of the premises wiring and grounding system supplying the equipment. Determine the quality of the ac voltage supplying the equipment. Determine the sources and impact of power system disturbances on equipment performance. Analyze the survey data to identify cost-effective improvements or corrections, both immediate and future. The key is to understand and define the problem before attempting to solve it. The following are some of the parameters that need to be defined: When did the problem start? What type of equipment is experiencing problems? What types of equipment malfunctions or failures are occurring (e.g., data loss, lock-ups, component damage)? When do the problems occur (e.g., time of day, day of week, particular system operation)? Are coincident problems occurring at the same time (e.g., lights flicker and motor slowdown)?
28 PUBLIC INFORMATION Copyright 2014 Rockwell Automation, Inc. All Rights Reserved. 28 What can Rockwell Automation services do for you? Site surveys and site power analyses (cont.) What are the possible problem sources at site (e.g., arc welders, air conditioning, copy machines)? What is the proximity to the equipment? Is there any existing or recently installed protection for equipment [e.g., transient voltage surge suppressor (TVSS) or isolation transformer]? Has the addition of protection or power conditioning equipment alleviated the problem or made it worse? Are there any possible environmental concerns [e.g., lightning, electrostatic discharge (ESD), and radio-frequency interference/electromagnetic interference (RFI/EMI)]? Are there any recent changes to the premises wiring distribution system (e.g., ground scheme, additional electrical service entrances, and equipment relocation)? Are there any recent changes to the electric utility s distribution system?
29 POWER SYSTEM STUDY QUESTIONNAIRE PUBLIC INFORMATION Copyright 2014 Rockwell Automation, Inc. All Rights Reserved. 29 This form requests details needed for a proposal. Provide as much details as possible to help us with an accurate estimation. Date of walk-through: RA Project Contact/Phone: Company Name: Company Address: Plant Electrical Contact: Contact Phone: Distributor: Distributor Phone: Distributor Name: Distributor Please provide at least one of the following two (2) options 1. Are one-line drawings available? YES NO (Circle one) What is the estimated percent accuracy of the drawings? (If one-lines are less than 70% accurate or not available this questionnaire will also be required.) (While on site, obtain electronic files if available. If paper copies only get photocopy or photograp.) (i.e % accurate) 2. If ACCURATE one lines are not available the following data is required: A Data Collection Transformer Nameplate Data Main/Utility Transformer Transformer 1 Transformer 2 Transformer 3 Transformer 4 Secondary Voltage kva Rating ( Continue on another sheet if required. ) Indicate operation characteristics: (i.e. 24hrs./7day, 8 hr/5 day, etc.) Indicate # of weeks of extended shutdown for the past 12 months: B Utility /Building Service Information i)is there a substation on-site? YES NO (If YES please list specifics on a separate sheet.) ii) Utility Entry Switch(es) (Specify which XFMR each switch is fed from) Amperage of Switch(es) iii)are there capacitor banks on-site? YES NO How many? iv) Alternate modes of operation (type/qty.): Co-gen: Bus-tie: Other: C Remainder of Facility i) Switchgear (SWGR) # of switches/gear SWGR (cont'd) # of switches/gear
30 PUBLIC INFORMATION Copyright 2014 Rockwell Automation, Inc. All Rights Reserved. 30 Utility Information Request Maximum Minimum Maximum Minimum Primary Utility Source 3P 3P SLG SLG Side Transformer Source Voltage Fault Fault 3P Fault Fault SLG Protective Size & Utility Company Name Description (KV) Current Current X/R Current Current X/R Device %Z (SAMPLE) ABC Energy Sample Road Meter # kA 10.7kA kA 7.2kA A cut-out S&C, SMC-4, E-rated 300kVA Delta-Wye 1.6%Z Utility Company Contact Information Name Address Phone
31 PUBLIC INFORMATION Copyright 2014 Rockwell Automation, Inc. All Rights Reserved. 31 Industrial Plant Services Our Goal is to partner with industrial facilities and consultants to provide a full range of electrical consulting services with uptime and maintainability in mind. Our Staff is comprised of registered engineers, designers, drafters, and technicians. Our experience allows us to better understand our customer s needs and provide a structured approach to project engineering and electrical services. Power Studies Power System Coordination Arc Flash solutions Power Quality monitoring and reports Load flow analysis Power factor correction Ground System testing Transient motor starting (TMS) Device evaluation Power one line development
32 Questions? PUBLIC INFORMATION Copyright 2013 Rockwell Automation, Inc. All Rights Reserved. 32
L19 - Combining the Latest Rockwell Automation Hardware and Software for Improved Energy Management
L19 - Combining the Latest Rockwell Automation Hardware and Software for Improved Energy Management PUBLIC INFORMATION Rev 5058-CO900E 2 Sustainable Production Inputs Add this flow to next slide Materials
More informationPower Quality. The Overlooked Productivity Variable
Power Quality The Overlooked Productivity Variable Up to 70 percent of unexplained downtime is caused by power quality problems. Chances are that your facility is affected Have you experienced unexplained
More informationT66 Central Utility Building (CUB) Control System Reliability, Optimization & Demand Management
T66 Central Utility Building (CUB) Control System Reliability, Optimization & Demand Management Name Doug Demian Title Application Engineer Date November 7 & 8, 2012 Rev 5058-CO900C Copyright 2012 Rockwell
More informationTech Byte 25: UPS Systems - Key To Ensuring Business Continuity - Part 1
I don t need a UPS system, I have a generator This is one of the most common misconceptions that business owners or managers have when evaluating power protection for the critical elements of their business.
More informationTel: AC Power for Business-Critical Continuity TM
Tel: +852-2690-4118 AC Power for Business-Critical Continuity TM Anticipating Technology Changes Through Adaptive Architecture Today, you need a power infrastructure that can work across your enterprise
More informationPGC 4000v2 POWER GENERATION CONTROLLER
PGC 4000v2 POWER GENERATION CONTROLLER THOMSON POWER SYSTEM PGC 4000v2 OFFERS THE FOLLOWING: Superior control & monitoring system for Thomson Power Systems advanced Series 2400 Switchgear (refer to separate
More informationEquipment Operation & Maintenance
Equipment Operation & Maintenance Many Facilities have: Very complex distribution systems. Many inter-locked backup power systems. Maintaining and troubleshooting the complex distribution system requires
More informationProcess and Power Control
Process and Power Control Insert Photo Here Sergio Gama Rockwell Automation Rockwell Automation Process Solutions User Group (PSUG) November 14-15, 2011 Chicago, IL McCormick Place West Copyright 2011
More informationSeries 2400 Paralleling Switchgear
Series 2400 Paralleling Switchgear SERIES 2400 PARALLELING SWITCHGEAR TYPICAL SERIES 2400 MULTIPLE GENERATOR/UTILITY PARALLELING SWITCHGEAR Intelligent, Configurable Switchgear for Distributed Generation,
More informationLiebert NXr Series 30kVA to 160kVA. AC Power for Business-Critical Continuity TM
Liebert NXr Series 30kVA to 160kVA AC Power for Business-Critical Continuity TM Anticipating Technology Changes Through Adaptive Architecture Today, you need a power infrastructure that can work across
More information3300 kw, Tier 3, Chilled Water, 70,000 ft 2
[Reference Design 22] 3300 kw, Tier 3, Chilled Water, 70,000 ft 2 DESIGN OVERVIEW Data Center IT Capacity 1100 kw per Data Hall 3 Independent Data Halls Design Application Range This design can be applied
More informationModular and Scalable Power Converters in the UPS Industry
A-PDF Split DEMO : Purchase from www.a-pdf.com to remove the watermark Modular and Scalable Power Converters in the Industry Ian Wallace Eaton Corporation, Innovation Center 1 Eaton Overview Eaton Electric
More informationOC IEEE IAS/PES Meeting February 21, 2013
San Diego International Airport: Building For The Future, Through Underground Distribution Automation and SCADA OC IEEE IAS/PES Meeting February 21, 2013 1 Presenter: Randy Denton, PE Under Ground Utility
More informationIntelligent Motor Control Solutions Process Solutions Summit
Intelligent Motor Control Solutions Process Solutions Summit Roger Dorsel Power Control Area Manager 5058-CO900F 2 3 Motor Control Technologies Scalable Low Voltage & Medium Voltage Solutions Across-the-Line
More informationDATA CENTER COLOCATION BUILD VS. BUY
DATA CENTER COLOCATION BUILD VS. BUY Comparing the total cost of ownership of building your own data center vs. buying third-party colocation services Executive Summary As businesses grow, the need for
More informationThe PowerLogic range. Gain energy insight and control
The PowerLogic range Gain energy insight and control The PowerLogic advantage PowerLogic is the world's largest and most advanced range of software and metering products for managing energy, giving suppliers
More informationASCO 7000 SERIES Power Control Systems
ASCO 7000 SERIES Power Control Systems 1 7000 SERIES PCS LINEUP ASCO 7000 SERIES Power Control Systems (PCS) offer the most advanced power management features for mission-critical facilities. Every 7000
More informationTD01 - Enabling Digital Transformation Through The Connected Enterprise
TD01 - Enabling Digital Transformation Through The Connected Enterprise Name Mukund Title Business Manager, Software, Asia Pacific Date January 22, 2018 Copyright 2016 Rockwell Automation, Inc. All Rights
More informationPLT. Breaker-based transfer switch open, closed or soft transition amps. Specification sheet
Specification sheet PLT Breaker-based transfer switch open, closed or soft transition 800 3000 amps Description PLT breaker-based transfer switches are designed for operation and switching of electrical
More informationLowering Lifecycle Costs
Lowering Lifecycle Costs with Intelligent Motor Control Centers Standards Certification Education & Training Publishing Conferences & Exhibits Speakers: Presented and Authored by Jeff M. Miller, PE, ENV
More informationAccelerating High Performance Manufacturing
Copyright 2013 Rockwell Automation, Inc. All Rights Reserved. Accelerating High Performance Manufacturing John Nesi Vice President Market Development Copyright 2013 Rockwell Automation, Inc. All Rights
More informationT87 - Building a Stronger Business with a Connected Workforce
T87 - Building a Stronger Business with a Connected Workforce PUBLIC PUBLIC 2 Agenda The Realities of Manufacturing The Connected Enterprise Building a Connected Workforce Taking Action The Realities of
More informationProven results Unsurpassed interoperability Fast, secure and adaptable network. Only EnergyAxis brings it all together for the Smart Grid
Proven results Unsurpassed interoperability Fast, secure and adaptable network Only EnergyAxis brings it all together for the Smart Grid Outage management & restoration Elster global strength Demand response
More informationCreate a sustainable, high-performance university campus.
Create a sustainable, high-performance university campus. Discover how to maximize efficiency, safety, and productivity with an integrated university infrastructure. Make the most of your energy SM Today
More informationSolve Compliance, Integration & Process Challenges Using Rich Data From Your Instrumentation
Solve Compliance, Integration & Process Challenges Using Rich Data From Your Instrumentation How Digital Mass Flow Controllers & Ethernet-Based Architectures Enhance Biotechnology Systems Solve compliance,
More informationCT233 - Intelligent Motor Control The Connected Enterprise
CT233 - Intelligent Motor Control The Connected Enterprise John Eddington Rockwell Automation Rev 5058-CO900E The Connected Enterprise at A GLANCE 22,000 EMPLOYEES 80+ COUNTRIES $6.62B Fiscal 2015 Sales
More informationDirty Power... A Guide to Surge Suppression & Filtering. Surge & Signal Protection for Business-Critical Continuity. EmersonNetworkPower.
Headquarters Surge & Signal Protection 328 Water Street Binghamton, NY 13901 T: 607-724-2484 T: 800-288-6169 F: 607-722-8713 Surge & Signal Protection for Business-Critical Continuity Dirty Power... A
More informationSmall Power Station Surge Protection Analysis and Plan
[Type the document title] Small Power Station Surge Protection Analysis and Plan By ArresterWorks Jonathan Woodworth ArresterWorks Page 1 Contents 1.0 Executive Summary... 3 1.1 Project Overview... 3 1.2
More informationAPRIL 2018 ABB Division Fact Sheets
APRIL 208 ABB Division Fact Sheets ABB financial summary Revenues by division 207 % of total revenues 24% 29% 9% PG EP 28% IA RM Revenues by region 207 % of total revenues 35% Europe Americas AMEA 46%
More information2009 E09PS E09PS E09PS E09PS E09PS E09PS38 IEEE 2009 E09PS39 E09PS40 E09PS41 E09PS42 E09PS43 IEEE 2008 E09PS44
1 CODE IEEE TRANSACTION POWER SYSTEM YEAR E09PS32 E09PS01 E09PS02 E09PS03 E09PS04 E09PS05 E09PS06 E09PS07 E09PS08 E09PS09 E09PS10 E09PS11 E09PS12 E09PS13 E09PS14 E09PS15 E09PS16 E09PS17 E09PS18 E09PS19
More informationQuantum Chargers Enhanced AC Line Transient Immunity
Introduction Quantum Chargers Enhanced AC Line Transient Immunity By: Nasser Kutkut, PhD, DBA Advanced Charging Technologies Inc. This white paper outlines the most common AC power quality disturbances
More informationDocument C0. Use for:
Date: July 27, 2015 Document C0 Use for: Connection of Electric Generation that will operate with an Open Transition (Category 1) between the Ameren System and the Generator or operate with a Synchronized
More informationPQube 3. Power Quality, Energy & Environment Monitoring. New Low-Cost, High-Precision
Power Sensors Ltd New Low-Cost, High-Precision Power Quality, Energy & Environment Monitoring PQube 3 Power Quality Class A Edition 3 Energy Revenue Grade class 0.2/0.2s Accuracy Additional AC, DC, and
More informationGE Enterprise Solutions. Digital Energy
GE Enterprise Solutions Digital Energy g Digital Energy we protect and connect the world s critical equipment to ensure safe, reliable power Our strength lies in the innovative people who deliver solutions
More informationHipulse-U UPS 80kVA - 500kVA Utmost Reliable Power Solution for Critical Business Applications
TM Hipulse-U UPS 80kVA - 500kVA Utmost Reliable Power Solution for Critical Business Applications WE ARE VERTIV Vertiv, formerly Emerson Network Power, designs, builds and services mission critical technologies
More informationIndustrial Facility Wide Protection
Industrial Facility Wide Protection Anywhere in your facility from the service entrance to the most critical production equipment, SolaHD can power your process control applications with our power conversion
More informationEaton s Electrical Sector: Targeting focused growth opportunities
Eaton s Electrical Sector: Targeting focused growth opportunities Revathi Advaithi Chief Operating Officer, Electrical Sector February 24, 2017 Electrical Sector growth today s themes Eaton is well-positioned
More informationSMARTER BUILDING. Give your buildings a new dimension Scalable solutions for energy and asset management
SMARTER BUILDING Give your buildings a new dimension Scalable solutions for energy and asset management 2 Give your buildings a new dimension, ABB s holistic new energy and asset management concept for
More informationPQube 3. Power Quality, Energy & Environment Monitoring. New Low-Cost, High-Precision
New Low-Cost, High-Precision Power Quality, Energy & Environment Monitoring PQube 3 Power Quality Class A Energy Revenue Grade class 0.2s Accuracy Additional AC, DC, and Environment Sensor Channels World
More information7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America
7 Best Practices for Increasing Efficiency, Availability and Capacity XXXX XXXXXXXX Liebert North America Emerson Network Power: The global leader in enabling Business-Critical Continuity Automatic Transfer
More informationBlueprint Data Center
Systems and Applications for Data Center Siemens Industy 1. Overview / Purpose In EM EA the datacenter market is seen as one of the fastest growing of the energy businesses. This blueprint is designed
More informationEnergy Action Plan 2015
Energy Action Plan 2015 Purpose: In support of the Texas A&M University Vision 2020: Creating a Culture of Excellence and Action 2015: Education First Strategic Plan, the Energy Action Plan (EAP) 2015
More informationPower Quality of Commercial Buildings - Advanced
Buildings - Advanced Hartford Steam Boiler One State Street P.O. Box 5024 Hartford, CT 06102-5024 Tel: (800) 472-1866 www.munichre.com/hsb May 2017 Background Power quality is a general term used to describe
More informationEnergy Solutions for Buildings
Energy Solutions for Buildings Making energy safe, reliable, efficient, productive and green Make the most of your energy SM 1 Solutions to enable and sustain energy savings Technology is crucial to make
More informationSECTION SOLID-STATE REDUCED VOLTAGE STARTERS
SECTION 26 29 13.16 PART 1 - GENERAL 1.1 THE REQUIREMENT A. General: The CONTRACTOR shall provide solid-state reduced voltage motor starters, complete and operable, in accordance with the Contract Documents.
More informationCLICK TO EDIT MASTER TITLE STYLE. AdvanTEC Solutions CHILLER PLANT HEALTH MANAGER
CLICK TO EDIT MASTER TITLE STYLE AdvanTEC Solutions CHILLER PLANT HEALTH MANAGER GREEN CHILLER PLANT Energy Efficiency Superior system performance Less energy consumption versus similar size building Operation
More informationDCIM Solutions to improve planning and reduce operational cost across IT & Facilities
DCIM Solutions to improve planning and reduce operational cost across IT & Facilities Presented by: Chi Sen, Director, Data Centre Software Solutions, APJ & EMEA Schneider Electric Data Center Solutions
More informationPARALLELING GENERATOR SET SYSTEMS AND DESIGN. Don Dentino Senior Strategy Consultant for Product Definition Caterpillar Inc.
PARALLELING GENERATOR SET SYSTEMS AND DESIGN Don Dentino Senior Strategy Consultant for Product Definition Caterpillar Inc. June 2018 INTRODUCTION The art of paralleling generator sets has evolved over
More informationAPPLICATION BRIEF. Branch Circuit Monitoring: Power Monitoring and Measurement in Production Facilities. Moving Away From a Break-Fix Model for Power
APPLICATION BRIEF Branch Circuit Monitoring: Power Monitoring and Measurement in Production Facilities Moving Away From a Break-Fix Model for Power This application brief will address many of the power
More informationGalaxy VX. From 500 to 1500 kw N+1 Parallel solutions up to 4000 kw 380V / 400V / 415V / 440V. schneider-electric.com/ups
Galaxy VX Highly efficient, scalable, three-phase power protection with flexible operating modes and ECOnversion for large facilities, data centers, and business-critical applications. From 500 to 1500
More informationResidential/Commercial/Industrial
Thank You For Purchasing the BASIC POWER UNIT from the team! 120 Marshalls Creek Road East Stroudsburg, PA 18302 570-872-9666 Residential/Commercial/Industrial IF YOU EXPERIENCE A PROBLEM WITH YOUR PURCHASE,
More informationSE Engineering, PC strives to be a leader in the power system engineering field by providing our customers with the highest level of quality,
SE Engineering, PC strives to be a leader in the power system engineering field by providing our customers with the highest level of quality, integrity, and innovation. Our mission is to offer the safest,
More informationHow Big Data Analytics Helps Hotels Improve Maintenance and Comfort, and Save Energy
How Big Data Analytics Helps Hotels Improve Maintenance and Comfort, and Save Energy Critical facility management drivers are impacting all industries Sustainability Big Data/Cloud Open Building Systems
More informationT48 - Integrating Your Power and Automation Control Systems
T48 - Integrating Your Power and Automation Control Systems PUBLIC Copyright 2018 Rockwell Automation, Inc. All Rights Reserved. 1 Integrated Power & Automation The Evolution of End Client Requirements
More informationEngineered Energy Solutions An Overview. Controls, Automation and Energy Conservation
Engineered Energy Solutions An Overview Controls, Automation and Energy Conservation Engineered Energy Solutions Independent Control System Integration and Engineering Firm specializing in the energy efficient
More informationCommunicating Submeter Data Via BACnet
BACnet Today and the Smart Grid This article was published in ASHRAE Journal, vember 2013. Copyright 2013 ASHRAE. Posted at www.ashrae.org. This article may not be copied and/or distributed electronically
More informationFloBoss TM 107/107E Flow Manager Overview
FloBoss TM 107/107E Flow Manager Overview New Technology New Features and Benefits. 1of 39 Introducing the FloBoss 107 The FloBoss 107 Flow Manager introduces a new technology platform to the FloBoss family
More informationSYRACUSE UNIVERSITY GREEN DATA CENTER NYSERDA MONITORING PLAN BHP ENERGY LLC. February 17, 2010 Revised
SYRACUSE UNIVERSITY GREEN DATA CENTER NYSERDA MONITORING PLAN BHP ENERGY LLC February 17, 2010 Revised SYRACUSE UNIVERSITY GREEN DATA CENTER NYSERDA MONITORING PLAN BACKGROUND INFORMATION Syracuse University
More informationMP-4000 motor protection. Protection, control and diagnostics
MP-4000 motor protection Protection, control and diagnostics Multi-function motor protection Introducing Eaton s MP-4000 motor protection relay Eaton s MP-4000 motor protective relay combines all the features
More informationDriving Proactive Facility Operations with Automated HVAC Diagnostics
Driving Proactive Facility Operations with Automated HVAC Diagnostics Turn HVAC Data into Actionable Information AKA Monitoring Based Commissioning Ongoing Commissioning Automated Fault Detection & Diagnostics
More informationPower Sensing Products
Our power monitoring sensors measure loads and improve performance by providing instantaneous True Power kw or accumulated kwh data. They are simple, reliable and accurate. Digital communications are available
More information84 kw, Tier 3, Direct Expansion, 937 ft 2
[Reference Design 42] 84 kw, Tier 3, Direct Expansion, 937 ft 2 DESIGN OVERVIEW Data Center IT Capacity 84 kw Target Availability Tier 3 Annualized PUE at 100% Load 1.712 Total Racks and Average Density
More informationCalculating Total Power Requirements for Data Centers
Calculating Total Power Requirements for Data Centers White Paper 3 Revision 1 by Victor Avelar > Executive summary Part of data center planning and design is to align the power and cooling requirements
More information9.6 MW, Traditional IT and OCP-compatible, Indirect Air Economizer, m 2
[Reference esign 62] 9.6 MW, Traditional IT and OC-compatible, Indirect Air Economizer, 16970 m 2 ESIGN OVERVIEW ata Center IT Capacity 9.6 MW Target Availability Tier III with 2N power distribution and
More informationGetting Power Peace of Mind with Remote Data Center Monitoring and Management Through EcoStruxure IT
Getting Power Peace of Mind with Remote Data Center Monitoring and Management Through EcoStruxure IT Cavern Technologies - Lenexa, Kansas, US Cavern Technologies relies on Schneider Electric s solution
More informationMICROFUSION FEATURES OPTIONS CERTIFICATIONS (PENDING) THREE PHASE SCR POWER CONTROLLERS
MICROFUSION THREE PHASE SCR POWER CONTROLLERS FEATURES Auto-Ranging Input Voltage 24-600 VAC, 45-65 Hz AC Output 16, 32, 50, 80 Amps (@ 50 C 6000 ft) Control Features Microprocessor-based controller /
More informationENGINEERING AND SERVICES FIRM THAT SPECIALIZES IN HYDROELECTRIC POWER AND CONTROL SYSTEM DESIGN, OUR TEAM OF PROFESSIONALS HAVE WORKED TOGETHER
smallhydro PRIME ENGINEERING LIMITED IS AN ELECTRICAL ENGINEERING AND SERVICES FIRM THAT SPECIALIZES IN HYDROELECTRIC POWER AND CONTROL SYSTEM DESIGN, IMPLEMENTATION AND MAINTENANCE. OUR TEAM OF PROFESSIONALS
More informationECOWISE EM100 THE MULTI-FUNCTIONAL DEVICE SERVER
ECOWISE EM100 THE MULTI-FUNCTIONAL DEVICE SERVER The Most Application Versatile Smart Device in the Market The Ecowise series EM100 is a multi-functional monitoring & control smart device that embeds advanced
More informationKeeping the Lights On: Machine Monitoring Basics
Keeping the Lights On: Machine Monitoring Basics Predictive Maintenance Helps Reduce Process Downtime As manufacturers continually search for ways to cut costs and increase ROI, machine monitoring and
More informationPower Quality Monitor PowerMonitor 5000 M8
ROCKWELL AUTOMATION PROCUREMENT SPECIFICATION PROCUREMENT SPECIFICATION PowerMonitor 5000 M8 NOTICE: The specification guidelines in this document are intended to aid in the specification of products.
More informationNetworks TN, TT, IT networks 3 and 4-phase networks Up to 4 single-phase networks
Memory 256 MB 8 Tariffs Harmonics Pulse inputs and outputs Measurement accuracy 0.5 UMG 96RM Multifunction power analyser Communication (device-specific) Modbus (RTU) Profibus DP V0 Profinet TCP/IP M-Bus
More informationRockwell Automation ODVA Annual Meeting
Rockwell Automation ODVA Annual Meeting Copyright 2011 Rockwell Automation, Inc. All rights reserved. Topics Industrial Energy Management: Industrial GreenPrint Business Drivers Enabling Solutions Copyright
More informationTM01 - Developing Machines for the Fourth Industrial Revolution
TM01 - Developing Machines for the Fourth Industrial Revolution Bob Hicks OEM Segment Manager PUBLIC Copyright 2018 Rockwell Automation, Inc. All Rights Reserved. 1 Agenda Industry 4.0 and The Connected
More information2000 kw, Tier 3, Chilled Water, Prefabricated, sq. ft.
[Reference Design 64] 2000 kw, Tier 3, Chilled Water, refabricated, 23700 sq. ft. DESIGN OVERVIEW Data Center IT Capacity 2000 kw Target Availability Tier 3 Annualized E at 100% Load 1.64 in Miami, FL
More informationLiebert GXT4 UPS, 5kVA-10kVA Intelligent, Reliable UPS Protection
Liebert GXT4 UPS, 5kVA-10kVA Intelligent, Reliable UPS Protection Liebert GXT4 UPS, 5kVA-10kVA Systems: Best Protection for Critical Network Applications Today s converged networks require increased availability
More informationLiebert GXT MT kva
Liebert GXT MT+ 10-20 kva Liebert GXT MT+ UPS, 10 kva - 20 kva Intelligent, Reliable UPS Protection Liebert GXT MT+ is a true on-line UPS that delivers continuous, high-quality AC power to connected equipment
More informationIXcellerate Moscow One Datacentre - Phase 1 & 2 Overview
Contents 1. Document Purpose... 2 2. Facility Overview... 2 2.1 Technical Space... 2 2.2 Load Density... 2 2.3 Resilience... 2 2.4 Engineering Plant Maintenance & Service Restoration... 3 3. Engineering
More informationDesigned For Reliability Manufactured To Last
512/1024 samples/cycle IEC 62053-22 Class 0.2S Compliant IEC 61000-4-30 Class A Sag/Swell, Transient and Flicker Comprehensive Data Recording PQDIF & COMTRADE Compatible 5.7 Color LCD Display @ 640x480
More informationSmartStruxure Lite Solution Get control. Get efficient. Get value. Integrated small- to medium-sized building management
SmartStruxure Lite Solution Get control. Get efficient. Get value. Integrated small- to medium-sized building management Make the most of your energy SM Studies show that most buildings waste up to half
More informationSmartZone Rack Energy Kits Energy and Environmental Monitoring for Small Data Centers
SmartZone Rack Energy Kits Energy and Environmental Monitoring for Small Data Centers SmartZone Rack Energy Kits Energy and Environmental Monitoring for Small Data Centers SmartZone Rack Energy Kits Features:
More information7000 SERIES Power Switching Solutions. Closed Transition Transfer Switching. Delayed Transition Transfer Switching
7000 SERIES Power Switching Solutions Fig. 2: Four pole, Closed Transition Switch rated 1000 Amperes in Type 1 enclosure. Closed Transition Switching Closed Transition Switches feature main contacts that
More informationPSL. Power Quality & Energy Monitoring. PQube power quality & energy analyzer. Low-Cost, High-Precision
Low-Cost, High-Precision Power Quality & Energy Monitoring PQube power quality & energy analyzer AC and DC Monitoring Lab-Grade Accuracy Modular & Embeddable Plug-and-Play Functionality Direct Remote Communication
More informationUsing Manufacturing Intelligence for Wastewater Pre- Treatment Compliance
Insert Photo Here Using Manufacturing Intelligence for Wastewater Pre- Treatment Compliance Marty Fallon EZSoft, Inc. Rockwell Automation Process Solutions User Group (PSUG) November 14-15, 2011 Chicago,
More informationA drive dedicated to variable speed control for HVAC applications
A drive dedicated to variable speed control for HVAC applications Designed for easy installation in mechanical fan and pump systems with reliable connectivity to building automation networks. VTAC 9 Drive
More informationVLT 2800 DRIVE SPECIFICATIONS
VLT 2800 DRIVE SPECIFICATIONS Drive Input Power Input voltage 3 phase... 200 through 240, or 380 through 460; 3-phase all ratings 200 through 240, 1-phase through 2 HP Input voltage range for full output...
More informationIndustrial IT in a Connected Enterprise
Industrial IT in a Connected Enterprise Eric Eckman Channel Sales Manager, Central US & Central Canada 1 Failure Avoidance instead of Recovery 30+ patents for our time-tested technologies 21,000+ systems
More informationProduct Catalog. senseware.co Tysons Boulevard Floor 5 Tysons VA, 22102
Product Catalog 2018 senseware.co 571.766.6443 1775 Tysons Boulevard Floor 5 Tysons VA, 22102 TABLE OF CONTENTS Senseware Base Hardware..................................... 2 Environmental Sensors......................................
More informationElectronic Submeter with Advanced WiFi Ethernet Capability
SH RK 100S Electronic Submeter with Advanced WiFi Ethernet Capability AGGRESSIVE TECHNOLOGY W NEIndustry Leading Technology High Performance Metering Technology 0.2% Accuracy Class Revenue Certifiable
More informationGENERAL UL th EDITION BID SPEC: SURGE PROTECTIVE DEVICES Prepared by THOR SYSTEMS, INC.
[Refer to Engineering Notes at End of Spec] Section [16XXX] [264XXX] - SURGE PROTECTIVE DEVICES (SPDs) PART 1 - GENERAL 1.1 SCOPE A. This section includes Surge Protective Devices (SPDs) for low-voltage
More informationGeneration Interconnection Impact Study Report. For. Interconnection Customer Q0022
Generation Interconnection Impact Study Report For Interconnection Customer Q0022 Prepared by: PacifiCorp Date: 10/29/2003 Generation Interconnection System Impact Study Report Interconnection Customer
More information200 kw, Tier 3, Chilled Water, 5250 ft 2
[eference Design 4] 200 kw, Tier 3, Chilled Water, 5250 ft 2 DESIGN OVEVIEW Data Center IT Capacity 200 kw Adaptable from 50 kw to 600 kw Target Availability Tier 3 Annualized UE at 100% Load 1.67 in Miami,
More informationData Centre Solutions Expertly Engineered APC Management Software
Data Centre Solutions Expertly Engineered APC Management Software Data Centre Solutions Expertly Engineered A vendor neutral software suite, which provides a unified view and analysis of complex IT physical
More informationwhere we are, where we could be, how we can get there. 12/14/2011
Central Plant Optimization ASHRAE National Capitol Chapter - PES Wednesday, Nov 7, 2011 Dave Klee, LEED AP Director, Optimized Building Solutions Johnson Controls, Inc. 1 1 J o http://www.johnsoncontrols.com/cpo
More informationGridEye FOR A SAFE, EFFICIENT AND CONTROLLED POWER GRID
FOR A SAFE, EFFICIENT AND CONTROLLED POWER GRID SMART GRID VISION To solve today s energy and pollution problems, DEPsys believes that the world should be powered entirely by renewable energy. By applying
More informationThe Allen-Bradley PowerFlex Family of AC Drives
PowerFlex Tomorrow s World-Class AC Drive Technology The Allen-Bradley PowerFlex Family of AC Drives Setting a new standard for powerful performance and flexible control to meet the global needs of virtually
More informationLiebert NX Series. 30kVA to 200kVA. AC Power for Business-Critical Continuity TM
Liebert NX Series 30kVA to 200kVA AC Power for Business-Critical Continuity TM Anticipating Technology Changes Through Adaptive Architecture Today, you need a power infrastructure that can work across
More informationHow Do You Reduce Energy Costs And Prolong The Life Of Your Equipment?
How Do You Reduce Energy Costs And Prolong The Life Of Your Equipment? PowerLogic PM800 series power meters Buildings Industry Data Center DATA CENTER SOLUTIONS For More Information: (866) 787-3271 Sales@PTSdcs.com
More informationVERTIV SERVICE CAPABILITY
VERTIV SERVICE CAPABILITY VERTIV SERVICE CAPABILITY Service Offering Manage the health of your entire critical infrastructure with a service partner who can offer you business continuity. Exactly the level
More informationMedium Voltage Metal-Enclosed Thyristor-Switched Harmonic Filter Banks
66 Carey Road Queensbury, NY 12804 Ph: (518) 792-4776 Fax: (518) 792-5767 www.nepsi.com sales@nepsi.com Medium Voltage Metal-Enclosed Thyristor-Switched Harmonic Filter Banks General NEPSI's activar, Medium
More informationMotor Protection Solutions. Bulletins 193, 592, 809S, 813S, 814S, 817S and 825-P
Motor Protection Solutions Bulletins 193, 592, 809S, 813S, 814S, 817S and 825-P Motor Protection Solution Protection, Warning, Diagnostics and Control MachineAlert Monitoring Relays Bulletins 809S, 813S,
More information