Replacement of the University of Missouri Research Reactor (MURR) Cooling Towers
|
|
- Amie Wood
- 6 years ago
- Views:
Transcription
1 Replacement of the University of Missouri Research Reactor (MURR) Cooling Towers Les Foyto, Associate Director John Fruits, Reactor Manager Carl Herbold, Assistant Reactor Manager
2 Overview MURR Facility Cooling Tower History Tower Design Project Background and Timeline The Big Snag The Big Lag Lessons Learned Q & A
3 History of MURR Located in Columbia, Missouri October 13, 1966 Facility established initial criticality and licensed to operate at 5 MWs July 18, 1974 Facility uprated to 10 MWs September 1, 1977 Facility starts a 10 MW, 150-hour-per-week operating schedule September 1, 2006 Facility submits 20-year license renewal application to the NRC
4 Key Reactor Parameters MURR is a pressurized, reflected, heterogeneous, open pool-type, which is light-water moderated and cooled Maximum thermal power 10 MW Peak flux in center test hole 6.0E14 n/cm 2 -s Core 8 fuel assemblies (775 grams of U-235/assembly) Control blades 5 total: 4 boral shim-safety, 1 SS regulating Reflectors beryllium and graphite Forced primary coolant flow rate 3,750 gpm (237 lps) Forced pool coolant flow rate 1,200 gpm (76 lps) Primary coolant temps 120 F (49 C) inlet, 136 F (58 C) outlet Primary coolant system pressure 85 psia (586 kpa) Pool coolant temps 100 F (38 C) inlet, 106 F (41 C) outlet Beamports three 4-inch (10 cm), three 6-inch (15 cm)
5
6 Reactor Core Assembly 3-D View 2-D View
7 Funding for the Project Amount ~$84K Source Global Threat Reduction Initiative (GTRI) Reactor Conversion Program through a Work Order from Argonne National Laboratory This funding is part of the HEU/LEU fuel conversion project: Funded temporary cooling tower tie-ins Funded thermal-hydraulic study for new cooling towers ~$1.29 mil Funded purchase of new cooling tower Funded demolition of old cooling tower and installation of the new cooling tower Funded installation, rent and removal of temporary cooling towers Funded installation of data acquisition system
8 Previous Cooling Tower History 1964/65 Original 2 Cell Cooling Tower Installed 1973/74 3rd Cell added for 10 MW Power Uprate Cooling Tower Refurbished Cooling Tower Refurbished 2004/05 Cooling Tower Electrical Upgrades 7
9 Project Background Activity GTRI lays groundwork via thermal design study and replacement cost estimate NEUP provides catalyst, which GTRI prepared us for University Campus Facilities provides project management, contracts designer and general contractor GTRI provides temporary tower connections University Procurement purchases new cooling towers University Procurement leases temporary towers
10 Tower Design
11 Tower Design
12 Tower Design Three cells Original Wood frame, induced-draft, cross-flow, PVC fill Concrete basin/sump Two-speed 40 HP fans Cools 4688 gpm (296 lps) From 104 deg-f (40 C) To 87 deg-f (31 C) At 77 deg-f (25 C) wet-bulb temperature Three cells Current Stainless Steel frame, induceddraft, cross-flow, PVC fill Elevated Stainless Steel basin Two-speed 40 HP fans Cools 5400 gpm (341 lps) From 115 deg-f (46 C) To 86 deg-f (30 C) At 80 deg-f (27 C) wet-bulb temperature
13
14 Date Activity Project Timeline 09/26/11 Commenced installation of temporary cooling towers 10/10/11 Placed temporary cooling towers on service 10/19/11 Commenced demolition of old cooling tower 10/24/11 Commenced Installation of new cooling tower 12/30/11 New cooling tower essentially complete 01/02/12 Placed new cooling tower on service 01/17/12 Commenced removal of temporary cooling towers 01/18/12 Temporary cooling towers removed
15
16
17
18
19
20
21
22
23
24 The Big Snag Week of October 10 th, 2011 Monday Thursday Friday-Sunday Placed temporary cooling towers on service Noted excess and growing volume of water in basement sump Noted excess water makeup on temporary cooling towers Secured temporary booster pumps to minimize losses DIG, DIG, DIG
25
26
27 The Big Lag Noted decrease in performance of the two parallel primary heat exchangers Frequent backflushing did not resolve or improve thermal performance **Reactor power was reduced for a period of weeks**
28 9/2006 8/2006 7/2007 9/2007 8/2007 7/2007 6/2008 7/2008 6/2008 5/2008 4/2009 6/2009 5/2009 4/2009 3/2010 5/2010 4/2010 3/2010 2/2011 4/2011 3/2011 2/2011 1/2012 2/2012 1/2012 0/2012 9/2013 Log Mean Temperature Difference The Big Lag 100% 90% Mechanical Cleaning on 503A 80% 70% 60% 50% 40% 30% 20% 10% 0% Installation of Temporary Towers 503B 503A 503 Average Plate Replacement on 503B
29 The Big Lag Roughly 240 lb (110 kg) of calcium scale was removed HX was reassembled and retested in 36 hours
30 Lessons Learned Don t replace your cooling tower
31 Lessons Learned Don t replace your cooling tower The one part of your system you have the least access to will be the part that breaks
32 Lessons Learned Don t replace your cooling tower The one part of your system you have the least access to will be the part that breaks Significant operational impacts from proper chemistry control
33 Lessons Learned Don t replace your cooling tower The one part of your system you have the least access to will be the part that breaks Significant impact to proper chemistry control Clear and knowledgeable communication on leased equipment
34 Thank You For Your Attention, Any Questions???
Measuring and Managing a Data Center Cooling Shutdown
Measuring and Managing a Data Center Cooling Shutdown Columbia University Information Technology - August 24, 2012 Table of Contents Overview Timeline Cricket Graphs What s being graphed Mechanical Electrical
More informationFLEX Implementation. Roy Harter RLH Global Services. SAMG-D course, IAEA, Vienna, Austria October
FLEX Implementation Roy Harter RLH Global Services rlharter@aol.com SAMG-D course, IAEA, Vienna, Austria 19-23 October 2015 What is FLEX? US Nuclear Industry Response to NRC Mitigating Strategies Order
More informationLABVIEW APPLICATION: ENERGY LABORATORY UPGRADE
Session 3233 LABVIEW APPLICATION: ENERGY LABORATORY UPGRADE J. Howard Arthur Michael R. Sexton Mechanical Engineering Department Virginia Military Institute Lexington, VA 24450 Abstract This paper describes
More informationIndirect Adiabatic and Evaporative Data Centre Cooling
Indirect Adiabatic and Evaporative Data Centre Cooling Developed in response to the broadening of the ASHRAE recommended server inlet temperature envelope in 2008, Excool represents the most advanced
More informationupdate: HPC, Data Center Infrastructure and Machine Learning HPC User Forum, February 28, 2017 Stuttgart
GCS@LRZ update: HPC, Data Center Infrastructure and Machine Learning HPC User Forum, February 28, 2017 Stuttgart Arndt Bode Chairman of the Board, Leibniz-Rechenzentrum of the Bavarian Academy of Sciences
More informationRear Door Heat Exchanger
Vinod Kamath Power and Thermal Engineering Sep 16, 2005 Problem Statement Rack Power loads are high due to increased compute density. The impact is seen in datacenters as high inlet air temperatures to
More informationIndirect Adiabatic and Evaporative Data Center Cooling
Indirect Adiabatic and Evaporative Data Center Cooling Developed in response to the broadening of the ASHRAE recommended server inlet temperature envelope in 2008, Excool represents the most advanced technology
More informationData Center Energy Savings By the numbers
Data Center Energy Savings By the numbers Chris Kurkjian, PE HP Critical Facility Services provided by EYP Mission Critical Facilities 2008 Hewlett-Packard Development Company, L.P. The information contained
More informationHIGH EFFICIENCY Central Chiller
Blending Conveying Drying Process Cooling Heat Transfer Size Reduction HIGH EFFICIENCY Central Chiller Energy Efficient Modular & Expandable Virtually Eliminate Downtime Available in 20-60 ton single units,
More informationChiller Replacement and System Strategy. Colin Berry Account Manager
Chiller Replacement and System Strategy Colin Berry Account Manager Current Situation 4 Existing RTAA chillers All units 23 years old Limited service history One unit MUST be replaced immediately One unit
More informationRadiation Center Strategic Plan Mission, Vision, Goals and Strategies for Activities and Operations
Radiation Center Strategic Plan 2012 Mission, Vision, Goals and Strategies for Activities and Operations July 2012 Radiation Center Strategic Plan 2012 Mission, Vision, Goals and Strategies for Activities
More informationNew Nuclear Technology. NuScale Power Safe. Clean. Economic. Simple Small Modular Reactors. Congressional Briefing February 25, 2013
New Nuclear Technology NuScale Power Safe. Clean. Economic. Simple Small Modular Reactors Congressional Briefing February 25, 2013 Michael S. McGough Chief Commercial Officer NuScale Power, LLC 2012 NuScale
More informationEngine Control Workstation Using Simulink / DSP Platform (COOLECW) SENIOR PROJECT PROPOSAL
Engine Control Workstation Using Simulink / DSP Platform (COOLECW) SENIOR PROJECT PROPOSAL By: Mark Bright and Mike Donaldson Project Advisor: Dr. Gary Dempsey Date: Dec 11, 2008 1 Project Summary Cooling
More informationContents. Rev. 2, 5/12/2016 1
Answers to Frequently Asked Questions for CTI STD-201 Thermal Certification of Cooling Towers, Closed Circuit Coolers and Evaporative Refrigerant Condensers Contents What is CTI STD-201?... 3 To what equipment
More informationSilicon Valley Power Data Center Program Rebate Application
Contact Information Tax Status (check one) Sole Proprietor Contact Name Phone Corporation Partnership Company Email address Government Not-For-Profit Customer/Facility Information Company Name SVP Account
More informationComprehensive Energy Management & Utility Master Plan
Comprehensive Energy Management & Utility Master Plan OVERVIEW University of Utah & Health Science Campus Overview Campus Transformation Value Drivers and Challenges Integrated Energy Planning Approach
More informationSaving Water and Operating Costs at NREL s HPC Data Center
Saving Water and Operating Costs at NREL s HPC Data Center Thomas P. Carter, P.E. Johnson Controls Thomas.P.Carter@jci.com David Sickinger National Renewable Energy Laboratory David.Sickinger@nrel.gov
More informationChiller Plant Optimization: A Case Study
Presentation of Chiller Plant Optimization: A Case Study Presented by Michael S. Conway The site Large pharmaceutical client 5 MW cogen 88,000 PPH of boiler capability 8,200 tons of chiller capability
More informationThis standard sets forth a program. will certify that all models of a line of water cooling towers offered for sale by a specific
STD-201 CERTIFICATION PURPOSE This standard sets forth a program whereby the Cooling Technology Institute will certify that all models of a line of water cooling towers offered for sale by a specific manufacturer
More informationResolution 1 F (1 C) single point; degrees C or Calibration single or dual point Calibration F
RMS Rainwater Harvesting Series 100 Controller Specifications Measurement Performance Contacting Conductivity ph Range 0-10,000 µs/cm Range -2 to 16 ph units Resolution 1 µs/cm Resolution 0.01 ph units
More informationFilter Fan Unit LIGHT
Filter Fan Unit LIGHT Type LIGHT EC Technical Concept Technical Concept Filter Fan Unit LIGHT Product Description Filter Fan Units (FFUs) from M+W Products are designed to provide clean air to individual
More informationM. Middleton, R.E. Williams, Bryan Eyers and Dan Khan NIST Center for Neutron Research TRTR 2016 August 25, 2016
Lessons Learned using a PLC for Process Control M. Middleton, R.E. Williams, Bryan Eyers and Dan Khan NIST Center for Neutron Research TRTR 2016 August 25, 2016 Lessons Learned using a PLC for Process
More informationInstallation of a Second CLICIT Irradiation Facility at the Oregon State TRIGA Reactor
Installation of a Second CLICIT Irradiation Facility at the Oregon State TRIGA Reactor Robert Schickler and Steve Reese Oregon State University, 100 Radiation Center Corvallis, OR, 97330 USA Corresponding
More informationTechnical Concept. Filter Fan Unit LIGHT. Type LIGHT AC Type LIGHT EC
Technical Concept Filter Fan Unit LIGHT Type LIGHT AC Type LIGHT EC Filter Fan Unit LIGHT Technical Concept Product Description Filter Fan Units (FFUs) from M+W Products are designed to provide clean air
More informationIT COOLING EVAPORATIVE COOLING SYSTEM. 2 STAGE INDIRECT ADIABATIC COOLING SYSTEM FOR LARGE DATA CENTERS FROM 80 TO 320 kw
IT COOLING EVAPORATIVE COOLING SYSTEM 2 STAGE INDIRECT ADIABATIC COOLING SYSTEM FOR LARGE DATA CENTERS FROM 8 TO 3 kw IT COOLING EVAPORATIVE COOLING SYSTEM ADIABATIC COOLING FOR HIGH EFFICIENCY - Variable
More informationMK SERIES CROSS FLOW COOLING TOWER
The Ultimate Cooling Machine MK SERIES CROSS FLOW COOLING TOWER CERTIFIED PERFORMANCE DURABLE ENERGY & SPACE SAVING MODEL DEFINITION FOR MK2348E-2BI MK 2348 E 2 B I CROSS FLOW TYPE BOX SIZE MOTOR SIZE
More informationAssembly and Maintenance
Assembly and Maintenance Assembly and Maintenance Test Pumps Pressure Test Pumps Tests all types of installations such as heating, compressed air and refrigeration systems, oil installations, fire lines
More informationType. Facts. 441, 442 Full nozzle DIN. Flanged Safety Relief Valves spring loaded. The-Safety-Valve.com. Metric Units LWN E
Type 441, 442 DIN Flanged Safety Relief Valves spring loaded Metric Units Facts The-Safety-Valve.com LWN 468.01-E DIN, ANSI 40 Cap H2 19 Lock nut 18 Adjusting screw with bushing 16 Upper spring plate 12
More informationSputtering Sensor ADVANTAGES
The INFICON is specifically designed for use in any sputtering process. The sensor body and cooling tubes are gold plated beryllium copper for maximum cooling efficiency in the sputtering environment.
More informationDUKE UNIVERSITY CONSTRUCTION STANDARDS
1 00 01 10 Table of Contents DIVISION 00: PROCUREMENT AND CONTRACTING REQUIREMENTS 00 01 10 Table of Contents 06.17.2014 00 21 13 Instructions to Bidders 11.08.2013 00 22 13 Supplementary Instructions
More informationStandard Circulating Pumps
Product review Range: 1 1 3Q [ m³/h] Hz - North America 1 3 1 1 1.x1 1.x x x3 x 1 1 Q [ US gpm] >Single-head pumps: Seal-less circulator with flanged connection. Two speed, manually adjustable to match
More informationLADWP POWER INFRASTRUCTURE PLAN
LADWP 2017-18 POWER INFRASTRUCTURE PLAN Introduction LADWP has built a vast power generation, transmission and distribution system that spans five Western states, and delivers electricity to about 4 million
More informationUPGRADE PROGRAM. V250 Series Pumps vs V301 Series Pumps. Technical Memo
UPGRADE PROGRAM V250 Series Pumps vs V301 Series Pumps Technical Memo INDEX Outline drawings ISO100 3 Outline Drawing CFF6 5 Technical Specification 7 Notes 8 Accessories 8 Controller comparison 9 Outline
More information98 Series Back Pressure. Valve Link. Features. Fisher Controls. August 1993 Bulletin 71.4:98
Series Back Pressure and Type Relief VL000 Valves FIELDVUE Valve Link Fisher Controls August Bulletin.: The Series (figure ) is used for back pressure or relief applications in liquid, gas, air, and steam
More informationExample. Section: PS 709 Examples of Calculations of Reduced Hours of Work Last Revised: February 2017 Last Reviewed: February 2017 Next Review:
Following are three examples of calculations for MCP employees (undefined hours of work) and three examples for MCP office employees. Examples use the data from the table below. For your calculations use
More informationMCFCW-20-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 60,000 BTUH
MCFCW-20-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 60,000 BTUH 1 Chilled and Hot Water Fan Coil High Static 4-Pipe Nominal
More informationCustomer Responsibilities
For Research Use Only. Not for use in diagnostic procedures. Thank you for purchasing the Agilent G5590A BenchCel Workstation. To get you started and to assure a successful and timely installation, please
More informationDigital Realty Data Center Solutions Digital Chicago Datacampus Franklin Park, Illinois Owner: Digital Realty Trust Engineer of Record: ESD Architect
Digital Realty Data Center Solutions Digital Chicago Datacampus Franklin Park, Illinois Owner: Digital Realty Trust Engineer of Record: ESD Architect of Record: SPARCH Project Overview The project is located
More information1/28/2013. ASHRAE Standard ASHRAE Standard Aiming at 50% Energy Savings For ASHRAE Standard 90.
-203-203 Stephen V. Skalko, P.E. Chair SSPC 90. Aiming at 50% Energy Savings For 90.-203 ASHRAE Winter Meeting January 28, 203 AIA Objectives for the Session Develop basic understanding of different formats
More informationMCFCW-08-4LS-1 (4-Pipe) Low Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 24,000 BTUH
MCFCW-08-4LS-1 (4-Pipe) Low Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 24,000 BTUH 1 Chilled and Hot Water Fan Coil Low Static 4-Pipe Nominal Size:
More informationFair City Plaza. Task: Diagnose problems, recommend improvements for small municipal district cooling system
Fair City Plaza Task: Diagnose problems, recommend improvements for small municipal district cooling system The Fair City Plaza district cooling system provides chilled water to five buildings in a downtown
More informationArtisan Technology Group is your source for quality new and certified-used/pre-owned equipment
Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment FAST SHIPPING AND DELIVERY TENS OF THOUSANDS OF IN-STOCK ITEMS EQUIPMENT DEMOS HUNDREDS OF MANUFACTURERS SUPPORTED
More informationMCFCW-06-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 18,000 BTUH
MCFCW-06-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 18,000 BTUH 1 Chilled and Hot Water Fan Coil High Static 4-Pipe Nominal
More informationData Center Trends and Challenges
Data Center Trends and Challenges, IBM Fellow Chief Engineer - Data Center Energy Efficiency Customers challenges are driven by the following Increasing IT demand Continued cost pressure Responsive to
More informationLAKEWOOD INSTRUMENTS MODEL 1575e WATER TREATMENT CONTROLLER
LAKEWOOD INSTRUMENTS MODEL 1575e WATER TREATMENT CONTROLLER The Model 1575e uses the latest in microprocessor capability, giving the user a high level of application flexibility. A large illuminated graphics
More informationExcellent location for Data Center Campus in Hanko
Excellent location for Data Center Campus in Hanko CAMPUS LOCATION AND LOGISTICS Ideal Data Center site location Hanko Data Center campus is located in the City of Hanko, Southern Finland The site is ideal
More informationAPC APPLICATION NOTE #126
#16 Selection Procedure for Inow Chilled Water Products By Greg Uhrhan, P.E. and Scott Buell Abstract Proper selection of Inow chilled water cooling systems requires an engineer or technical salesperson
More informationButterfly Control Valve. DMK/6 Series
Butterfly Control Valve DMK/6 Series UL Listed for US and Canada UL 842 and ULc C125 & C842 File # MH 18741 Models DMK 707/6 (3/4 NPT) DMK 710/6 (1 NPT) DMK 712/6 (1 1/4 NPT) DMK 715/6 (1 1/2 NPT) DMK
More informationGP SERIES Packaged Chillers
Blending Conveying Drying Process Cooling Heat Transfer Size Reduction GP SERIES Packaged Chillers Comprehensive Flexible Versatile Compact unitary designs available in a variety of configurations from
More informationNext Generation DCP Optimization using MV VSDs
Next Generation DCP Optimization using MV VSDs Vivek Apte Regional Product Director Johnson Controls - Middle East Cell : +971506243059 IDEA 2016- Dubai 1 Central Plant Optimization Energy and operating
More information+91-8048763833 Janani Enterprises, Coimbatore http://www.industrialcoolingequipments.com/ We are one of the leading Manufacturer, Wholesaler, Trader, Exporter and Importer of a wide range of Cooling Tower,
More informationCase Study: Energy Systems Integration Facility (ESIF)
Case Study: Energy Systems Integration Facility (ESIF) at the U.S. Department of Energy s National Renewable Energy Laboratory (NREL) in Golden, Colorado OFFICE HIGH BAY LABORATORIES DATA CENTER 1 Case
More informationOPTIONS FOR INFORMATION COMMUNICATION TECHNOLOGY (ICT) PROVISION AND SUPPORT CONTRACT
OPTIONS FOR INFORMATION COMMUNICATION TECHNOLOGY (ICT) PROVISION AND SUPPORT CONTRACT 1 PURPOSE OF REPORT 1.1 The Council contracts externally for the provision of ICT services and, with marginally in
More informationVirtual Temperature Cycle Test (TCT) for validation of indirect Charge Air Coolers and Exhaust Gas Recirculation Coolers
Virtual Temperature Cycle Test (TCT) for validation of indirect Charge Air Coolers and Exhaust Gas Recirculation Coolers STAR Global Conference 2014 Vienna, March 17-19 G. Apostolopoulos, R. Stauch, C.
More informationApplications: Page 60. Chemical manufacturing / processing plants Paint manufacturing facilities Bulk truck terminals Refineries
CSA - Class I Div. 1 - Groups C & D CSA - Class I Div. 2 - Groups A, B, C & D CSA - Class II Div. 1 & 2 - Groups E, F & G CSA - Class III UL 844 - Class I Div. 1 - Groups C & D UL 844 - Class I Div. 2
More informationPassive RDHx as a Cost Effective Alternative to CRAH Air Cooling. Jeremiah Stikeleather Applications Engineer
Passive RDHx as a Cost Effective Alternative to CRAH Air Cooling Jeremiah Stikeleather Applications Engineer Passive RDHx as a Cost Effective Alternative to CRAH Air Cooling While CRAH cooling has been
More informationSlide 1. Slide 2. Voisey s Bay Project Update
Slide 1 Slide 2 Voisey s Bay Project Update October 2003 Slide 3 Presentation Overview Project Components Mine and Concentrator Exploration Argentia Hydromet R&D Innovation Centre Expenditure Forecast
More informationICS COOL ENERGY THE TEMPERATURE CONTROL SPECIALISTS
ICS COOL ENERGY THE TEMPERATURE CONTROL SPECIALISTS GLOBAL PRESENCE, LOCAL SERVICE WHERE WE MAKE IT WORK WHO WE MAKE IT WORK FOR ACCREDITATIONS i-chiller -10 C to 30 C 1.7 TO 505kW i-chiller COMPACT
More informationSaving Energy with Free Cooling and How Well It Works
Saving Energy with Free Cooling and How Well It Works Brent Draney HPC Facility Integration Lead Data Center Efficiency Summit 2014-1 - NERSC is the primary computing facility for DOE Office of Science
More informationSafety and Security a Single Entity at the JM-1 SLOWPOKE-2 Reactor Facility
Safety and Security a Single Entity at the JM-1 SLOWPOKE-2 Reactor Facility RONMCCREA CUSHNIE JOHN PRESTON The International Centre for Environmental and nuclear sciences Overview Facility Overview Project
More informationHenderson Mill Road 48 Water Line Issue. Thursday, July 23, 2015 Monday, July 27, 2015
Henderson Mill Road 48 Water Line Issue Thursday, July 23, 2015 Monday, July 27, 2015 Situation A grass cutting crew working in the area hit a fire hydrant on Henderson Mill Road The fire hydrant was directly
More informationDATA CENTER LIQUID COOLING
DATA CENTER LIQUID COOLING EFFICIENT, EFFECTIVE, SUSTAINABLE What is Liquid Cooling? Key Trends & Potential Inhibitors Why are Many Owner/Operators Making the Move? Types of Liquid Cooling Solutions Liquid
More informationCOLOR MEGARAD Cameras
State of the art camera regarding image quality and radiation tolerance with 720 TV-lines horizontal resolution and perfect color reproduction. Special inspection in high radiation areas and spaces. IVVI
More informationStandard Circulating Pumps
Product review Range: 1 1 3Q [ m³/h] Hz - North America 1 3 1 1 1.x1 1.x x x3 x 1 1 Q [ US gpm] >Single-head pumps: Circulating pumps with flanged connection > Applications: Drinking-water circulation
More informationCOOLING SOLUTIONS BY LABTECH INNOVATION INSPIRED
WATER CHILLERS COOLING SOLUTIONS COOLING SOLUTIONS BY LABTECH Even if water is one of the most precious and scarce resources, it is still largely used as coolant in many laboratories. Most of the water
More information4" MULTISTAGE CENTRIFUGAL SUBMERSED PUMPS COMPLETE WITH MOTOR
NOCCHI SCM 4 PLUS Maximum rigidity and resistance to water hammer, Strong resistance to the abrasive action of sand, Excellent hydraulic efficiency SCM 4 PLUS submersible pumps consist of a multi-stage
More informationGENERATOR ADDENDUM TO MAGNOLIA GARDENS ASSISTED LIVING COMPREHENSIVE EMERGENCY MANAGEMENT PLAN
Contact Person: Philip McCollum - Administrator Magnolia Gardens Assisted Living AL Lic# 10314 3800 62 nd Avenue North Pinellas Park, FL 33781 Phone: 727.489.6440 GENERATOR ADDENDUM TO MAGNOLIA GARDENS
More informationSTD-201 CERTIFICATION PURPOSE
STD-201 CERTIFICATION PURPOSE This standard sets forth a program whereby the Cooling Technology Institute will certify that all models of a line of water cooling towers offered for sale by a specific manufacturer
More informationXBR V4 INSTALLATION AND USER GUIDE
XBR V4 INSTALLATION AND USER GUIDE xbr V4 Installation and User Guide Page 1 of 18 Revision History Dash#/Rev Date Author Description 0.1 04/03/2013 Eric Anderson Initial draft 0.2 04/08/2013 Eric Anderson
More informationPerformance Test of Core Protection and Monitoring System with DLL for SMART Simulator Implementation
2014 KNS Spring Meeting in Jeju Performance Test of Core Protection and Monitoring System with DLL for Simulator Implementation BonSeung Koo, DaeHyun Hwang and KeungKoo Kim May 29-30, 2014 Korea Atomic
More informationFOX-50 Heat Flow Meter
FOX-50 Heat Flow Meter Site Preparation Guide Revision A Issued June 2016 Page 1 Table of Contents Table of Contents... 1 Ideal Setup... 2 System Components... 3 Instrument Measurements... 4 Utility Requirements...
More informationThermal Diffusivity Instruments DLF-2 with EM-1600
Thermal Diffusivity Instruments DLF-2 with EM-1600 Site Preparation Guide Revision A Issued February 2017 Table of Contents Table of Contents... 1 Ideal Setup... 2-3 System Components... 3 Instrument Measurements...
More informationIsotemp. Bath Circulators. Improve the productivity. of your lab with solutions. from Fisher Scientific
Isotemp Bath Circulators Improve the productivity of your lab with solutions from Fisher Scientific I s o t e m p B a t h Isotemp Refrigerated and Heating Bath Circulators Three Controller Choices: Programmable,
More information3D Galaxy II GH-WIU02. English User s Manual
3D Galaxy II GH-WIU02 English User s Manual 3D Galaxy II Liquid Cooling System Caution 1. Before pouring liquid coolant into the tank to test the liquid cooling system, please reconfirm all the tubes have
More informationDMT PERFORMING UNDER PRESSURE DMT. All-Media Pressure Scanner Features. Applications. Description 1/8
Features Low Pass Anti-aliasing Filter per Channel Up to ±0.05% System Accuracy EU Throughput Rates in excess of 100 Hz 10 BaseT Ethernet Interface, TCP & UDP Protocol Pressure Ranges from 5 psi (34 kpa)
More informationSERPENT Cross Section Generation for the RBWR
SERPENT Cross Section Generation for the RBWR Andrew Hall Thomas Downar 9/19/2012 Outline RBWR Motivation and Design Why use Serpent Cross Sections? Modeling the RBWR Generating an Equilibrium Cycle RBWR
More informationThe 5400A Series, Group D, end-of-line flame arrester is designed to prevent the propagation of flames into a storage vessel.
Varec 00A Series The 00A Series, Group D, end-of-line flame arrester is designed to prevent the propagation of flames into a storage vessel. Introduction Varec s have been the industry standard for over
More informationTechnology for Constructing Environmentally Friendly Data Centers and Fujitsu s Approach
Technology for Constructing Environmentally Friendly Data Centers and Fujitsu s Approach Hiroshi Nagazono In recent years, IT devices such as servers have come to have high performance and be highly integrated
More informationWHAT IS THE DIGI-RTU South 59 th Street Omaha, NE bes-tech.net
WHAT IS THE DIGI-RTU The Digi-RTU is a Heating, Ventilation, and Air Conditioning (HVAC) rooftop unit control kit that is both a demand management and energy usage device. It is designed to improve the
More informationBIG BUTTON PHONE WITH ONE TOUCH DIALING AND
FUTURE CALL LLC BIG BUTTON PHONE WITH ONE TOUCH DIALING AND 40db HANDSET VOLUME MODEL: FC-1507 USER MANUAL Please follow instructions for repairing if any otherwise do not alter or repair any parts of
More informationA 101 A B C. Variable flow-control valve, series DXC. Dynamic Flow Networking. Description. Content
101 DX Variable flow-control valve, series DX Pressure independent variable flow-control Dynamic hydronic balancing in full load and part load Integrated flow and temperature measurement Power supply U
More informationClose-coupled cooling
Close-coupled cooling Intelligently controlled high-performance InRow cooling for the IT environment APC TM by Schneider Electric close-coupled cooling products provide a modular, scalable, and predictable
More informationXBR V3 INSTALLATION AND USER GUIDE Rev 03. xbr V3 Installation and User Guide Page 1 of 14. (preliminary)
XBR V3 INSTALLATION AND USER GUIDE xbr V3 Installation and User Guide Page 1 of 14 Revision History Rev Date Author Description 01 07/03/2012 Eric Anderson Initial release 02 09/25/2012 Eric Anderson Clarification
More informationDOE EM Web Refresh Project and LLNL Building 280
STUDENT SUMMER INTERNSHIP TECHNICAL REPORT DOE EM Web Refresh Project and LLNL Building 280 DOE-FIU SCIENCE & TECHNOLOGY WORKFORCE DEVELOPMENT PROGRAM Date submitted: September 14, 2018 Principal Investigators:
More informationWO P-NF-L-M-407c Spec Submittal
WO2-2-10000-2P-NF-L-M-407c Spec Submittal General Specifications WO2-2-10000(801304) Width: IN/CM 136.25/346.07 Height: IN/CM 84.5/214.63 Depth: IN/CM 41.7/105.92 Dry weight: LB/KG 4000/1814.37 Operational
More information9861 Series. High Temperature Mass Flow Controllers/Meters. Overview. Product Description. Thermal Mass Flow
DS-TMF-9861-Series-MFC-eng August, 2018 Data Sheet 9861 Series 9861 Series Mass Flow Controller/Meters Thermal Mass Flow High Temperature Mass Flow Controllers/Meters Overview Originally developed by Unit
More informationAB x 1 HDMI switch with 3D and 4K support
AB7816 4 x 1 HDMI switch with 3D and 4K support EMXXX Product Title from CMS 2 ENGLISH Table of contents 1.0 Introduction... 2 1.1 Packing contents... 2 2.0 Panel description... 3 3.0 Frequently Asked
More informationshop online:
Process systems Liquid ring vacuum pumps Single stage pumps 8 Alpha series single stage liquid ring vacuum pumps 9 AL series single stage liquid ring vacuum pumps 97 Two stage pumps 00 SHR series liquid
More informationOvercoming the Challenges of Server Virtualisation
Overcoming the Challenges of Server Virtualisation Maximise the benefits by optimising power & cooling in the server room Server rooms are unknowingly missing a great portion of their benefit entitlement
More information2013 AWS Worldwide Public Sector Summit Washington, D.C.
Washington, D.C. How to Buy the Cloud Brett McMillen, Principal Doug VanDyke, General Manager Changing IT Acquisition Strategies Old World IT Price lock Vendor lock-in Rigid CLIN structure CapEx Budget
More informationREPORT TO THE BUSINESS ADMINISTRATION COMMITTEE
REPORT TO THE BUSINESS ADMINISTRATION COMMITTEE RECOMMENDATION TO AWARD A SOLE SOURCE CONTRACT FOR MAINTENANCE AND TECHNICAL SUPPORT OF THE CENTRAL HEATING AND COOLING PLANT S DISTRIBUTED CONTROL SYSTEM
More informationClosed-Loop Water-Cooled Enclosure GL840ES-3048-CLWCE. High Performance 30kW Closed-Loop Water-Cooled Enclosure COOL THE SERVERS, NOT THE ROOM!
High Performance 30kW Closed-Loop Water-Cooled Enclosure COOL THE SERVERS, NOT THE ROOM! 1 COOL THE SERVERS, NOT THE ROOM! Overcoming Data Center Challenges The Great Lakes Closed-Loop Water-Cooling System,
More informationASHRAE IRELAND HVAC FOR DATA CENTRES. Michael Geraghty Building Services Engineer (DipEng) Company owner and managing director
ASHRAE IRELAND HVAC FOR DATA CENTRES Michael Geraghty Building Services Engineer (DipEng) Company owner and managing director michael@entropic.ie OVERVIEW OF THE MARKET SITUATION IN IRELAND Relative Data
More informationCV activities on LHC complex during the long shutdown
CV activities on LHC complex during the long shutdown Serge Deleval Thanks to M. Nonis, Y. Body, G. Peon, S. Moccia, M. Obrecht Chamonix 2011 Contents Maintenance Upgrade projects UW pumping upgrade Back
More informationMotivair MLC-SC Air-Cooled Scroll Chillers Tons
INNOVATE DESIGN APPLY www.motivaircorp.com Motivair MLC-SC Air-Cooled Scroll Chillers 100 285 Tons OUR BUSINESS IS COOLING YOURS. When commercial grade isn t enough Businesses who function in today s advanced
More informationControl systems for spallation target in China ADS systems
The 15th Intern. Conf. on Accelerator and Large Experimental Physics Control Systems (ICALEPCS15) Control systems for spallation target in China ADS systems Zhiyong He, Qiang Zhao,Wenjuan Cui,Yuxi Luo,
More informationAgenda Date: 8/23/17 Agenda Item: SB CLEAN ENERGY
Agenda Date: 8/23/17 Agenda Item: SB STATE OF NEW JERSEY Trenton, New Jersey 08625-0350 www.nj.gov/bpu/ CLEAN ENERGY IN THE MATTER OF THE CLEAN ENERGY PROGRAM AUTHORIZATION OF COMMERCIAL AND INDUSTRIAL
More informationComputer Controlled Steam Turbine, with SCADA TTVC
Technical Teaching Equipment Computer Controlled Steam Turbine, with SCADA TTVC EDIBON SCADA System Teaching Technique used 2 Control Interface Box 5 Cables and Accessories 6 Manuals 3 Data Acquisition
More informationInstallation Manual. 1.Included Accessories. System Controller SC-201-6M INT. Requests to Installers *SHA8754 C*
System Controller SC-201-6M INT Installation Manual Potential dangers from accidents during installation and use are divided into the following two categories. Closely observe these warnings, they are
More informationGreen IT Project: The Business Case
Green IT Project: The Business Case Indumathi Lnu University at Albany DATE We will discuss Identifying green IT projects Funding green IT projects Building the business case Case study: University at
More information