AT-VLS-104DE. Manual. ATAL B.V. Ampèrestraat NL-1446 TR PURMEREND. Postbus 783 NL-1440 AT PURMEREND T (+31) F (+31)

Size: px
Start display at page:

Download "AT-VLS-104DE. Manual. ATAL B.V. Ampèrestraat NL-1446 TR PURMEREND. Postbus 783 NL-1440 AT PURMEREND T (+31) F (+31)"

Transcription

1 AT-VLS-104DE Manual ATAL B.V. Ampèrestraat NL-1446 TR PURMEREND Postbus 783 NL-1440 AT PURMEREND T (+31) F (+31) E info@atal.nl I

2 Inhoud Manual General description Regulator mounting and connection Preparation to operation Procedure of instrument connection Dimensions Installation Installation procedure Operation checking Visual check Communication check via a LAN Description of device function and setting Relay outputs Carbon dioxide concentration measurement Actual regulator preset measurement part Value assigned to output relay When close output relay Regulator setting change part of measurement unit Setting with PC and TSensor software Setting with using regulator keys Extended setting mode Restore to Factory default measurement part Regulator configuration Ethernet interface Alarms Ethernet interface Analogue values Factory default Ethernet interface Communication protocols Modbus protocol SMTP SNMPv SNTP Syslog protocol SOAP What to do when Error States of the device Readings on LCD display Preventive maintenance and calibration Technical specification Technical parameters Common parameters AT-VLS-104DE - CO 2 regulator AT-VLS-101DE - CO 2 regulator AT-VLS-102DE temperature, relative humidity and CO 2 regulator AT-VLS-106DE temperature, relative humidity and CO 2 regulator Relative humidity and temperature restriction Value computed from measured relative humidity and temperature Operating conditions End of operation Technical support and service Appendix A

3 General safety rules The following summary is designed to prevent injury hazards or device damage. Operate the instrument in accordance with this manual to prevent electric trauma. Service should be performed by a qualified person only. Use a safety ac/dc adapter. Use only an adapter with the power voltage recommended by its manufacturer and which is approved by proper standards. Check that the adapter has undamaged cables and cover. Connect and disconnect correctly. Do not connect and disconnect cables if the device is under electric voltage. Do not use the instrument without the cover. Do not use the instrument, if it does not work correctly. If the instrument seems not to work correctly, have it checked by a qualified service person. Do not use the instrument in an explosive environment. Read instruction manual before the first device connection, please.. 3

4 1. General description The regulators are designed for online measurement of temperature ( C or F), relative humidity and carbon dioxide concentration of air. Measured temperature and relative humidity are recomputed to following humidity expression: dew point temperature, absolute humidity, specific humidity, mixing ratio and specific enthalpy. The regulators are designed to be operated in a chemically non-aggressive environment. 104DE DE - - Type Temperature Humidity CO 2 Computed value AT-VLS- AT-VLS- AT-VLS- 102DE AT-VLS- 106DE The device is equipped with two relay outputs for alarming or controlling of external devices. It is possible to assign any input value to each relay, to set comparing limit, delay, hysteresis and acoustic alarm or change its status by far control with using of Modbus communication protocol. The device is communicating through Ethernet interface. The device is internally separated into two units. The first unit provides measurement and controlling of output relays there is possible to change these parameters directly through device s keys or TSensor software. The second unit provides all Ethernet services, its configuration is possible through Telnet terminal or TSensor software (this setting is impossible to change through device s keys). Measured and calculated values are available from Ethernet interface or are displayed on LCD. If there are two values displayed at one LCD line, they are periodically switched between both readings with period of 4 seconds. Display can be switched OFF totally. On the left LCD side there are placed three LEDs for CO 2 zone level indication. The following formats are supported: WWW pages with user-design possibility Modbus protocol SNMPv1 protocol SOAP The instrument may send a warning message to several defined points if the measured value gets out of adjusted limits. There are the following possible ways to deliver the warning report: to send an to maximum of three addresses to send a SNMP trap to maximum of three IP addresses to display an alarm state on the device WWW page to send a message to Syslog server Alarm limits may be set via TSensor software, Modbus, Telnet or a SNMPv1 protocol. The alarm state may be read via the device WWW pages, Modbus or the SNMPv1 protocol. The value assign to each relay is possible through TSensor software or through device s keys. If Power over Ethernet is needed, it is necessary to use some PoE Splitter. Tested is e.g. D-Link DWL- P50. Regulator itself does NOT support PoE internally! Regulator supports Internet protocol version 4 (IPv6 is NOT supported)

5 2. Regulator mounting and connection Regulators are designed for wall mounting. Device must be mounted on the plane surface to prevent its deformation. Mounting holes and connection terminals are accessible after demounting of four screws in the corners of the box and removing the lid. There is recommended to use screws with half round head with cross-recessed screw ST 3.9 (DIN 7981). External probe for measuring the concentration of CO2 unpack and connect to the device. Lace the lead-in cable with outer diameter of 3 to 6.5 mm through the glands at the case wall and connect them according schematic below. Terminals are selfclamping and can be opened by a suitable screwdriver. For the opening, insert the screwdriver to smaller terminal hole and lever by him. Do not forget to tighten glands and case lid with inserted packing after cables connecting. Insert attached plug into unused cable glands too. Do not connect the regulator under voltage. It is not recommended to use the device AT-VLS- 102DE and external RH+T probe of AT-VLS-106DE regulator for long time under condensation conditions. It could be the cause of water steam condensation inside the sensor s cover into water phase. This liquid phase stays inside sensor s cover and can t escape from the cover easily. It can dramatically increase response time to relative humidity change. If water condensation occurs for longer time it can cause sensor damage. Similar effect can occur under water aerosol conditions. The communication cable must be placed as far as possible from potential interference sources. Electrical system (wiring) may be done only by a worker with required qualification by rules in operation. 3. Preparation to operation To provide all Hx5xx regulator functions it is necessary to make its setting through PC to satisfy your requirements. Requested parts necessary for operation: ac/dc adapter 9-30V, 200mA or PoE splitter RJ-45 LAN connection free IP address in your network Contact network administrator to get free IP address. Warning! Reliability of warning messages reception ( , trap) depends on current accessibility of required network services. It is recommended to protect device from unauthorized access to device settings and cables connection. 5

6 3.1. Procedure of instrument connection The cables, power adapter or PoE splitter connect in order as shown in the pictures. After power supply connection, make regulator configuration. AC/DC power adapter PoE splitter 6

7 4. Dimensions AT-VLS-101DE AT-VLS-102DE 7

8 AT-VLS-104DE 8

9 AT-VLS-106DE 9

10 5. Installation It is necessary to assign a new suitable IP address to the device at the first connection to it in order to prevent collisions with already existing network IP addresses, and make the address conform to the local habits. If installing several new devices, connect them to the network one after another! If a suitable IP address is not known, contact your network administrator and ask him for the following: IP address of regulator IP address of gateway Network mask The IP gate address and the network mask need not be specified if the device will be operated only in a local network. If you set the IP address to one which is already used in the network the device will NOT work correctly and collisions in the network will appear. It is possible to set the IP address by DHCP server. Device setting from the manufacturer: IP address: Gateway: not set Value assigned to Relay1 and Relay2: none Password for setting through keys (PASS): 0000 Password for setting via TSensor: none Value shown at first LCD line: temperature / CO2 - by device type Value shown at second LCD line: relative humidity / dew point temp. - by device type Temperature unit: C Computed value preset: dew point temperature Relay response for error: stay unchanged at previous condition Acoustic alarm: off LED indication of CO 2 concentration: up to 1000 ppm lights green LED, between 1000 and 1200 ppm lights yellow LED and over 1200 ppm lights red LED altitude: 300 m above see level at the installation site 5.1. Installation procedure run TSensor software (default regulator IP address is ) or use command line at PC with command telnet Telnet provides to set all Ethernet services. For setting of measurement and controlling of output relays use keys see chapter Regulator setting change part of measurement unit at page 13. assign new regulator IP address make your own regulator setting by your requirements (alarm settings, used units, and trap sending...) and save settings 6. Operation checking 6.1. Visual check When power source is on, there are actually measured values shown on LCD (if the LCD has not been switched off). When Ethernet cable is connected, there is one light on its connector lighting. 10

11 6.2. Communication check via a LAN Open a browser of WWW pages and enter the devices IP address into appropriate field. Example: Regulator shows its name, serial number, measured values, alarm status and alarm settings or shows message Access denied in case of web pages are disabled or setting through Telnet is in operation. 7. Description of device function and setting Information from regulator is available directly through LCD or you can read them with one of next communication protocols. For communication through some communication protocol (SNMPv1, Modbus, SOAP) there is necessary to have installed appropriate software supporting appropriate communication protocol on PC. Such software is not included in the delivery! The device is internally separated into two units. The first unit provides measurement and controlling of output relays these parameters are possible to change directly through device s keys or TSensor software. The second unit provides all Ethernet services, its configuration is possible through Telnet terminal or TSensor software (this setting is impossible to change through device s keys) Relay outputs Regulator is equipped with two relay outputs. It is possible to assign any input or computed value or far control to each relay, to set comparing alarm limit, if the relay may close if measured value is higher (Hi) or lower (Lo) than preset limit, delay for while must be preset condition true before relay close its contact and hysteresis for return to open status. Each relay status is indicated with LED diode and shown on LCD with corresponding symbols or. The output relays of device are not able to switch power circuits or higher voltages. In such case we should use suitable type of power relays with coil in accordance to chapter Common parameters. For wiring see Appendix A Carbon dioxide concentration measurement Principle of CO 2 concentration measurement is based on Non-Dispersive Infrared Technology (NDIR). It is maintenance free because of the patented auto calibration feature, compensating for the effects of aging and therefore a guarantee for outstanding long-term stability. If the device is in operation permanently, an auto-adjustment will start automatically after 24 hours operation each. Measured values can be read in SLOW mode (filtered, averaged) or in FAST mode (current values without averaging). SLOW mode has advantages in applications like climate control because of filtering short time peaks. As an example exhaled air from an employee passing the sensor could affect the climate control negatively with a short response time because the control would trigger a change of the ventilation based on this onetime measurement. On the contrary in FAST mode no software filter is used for calculating the output value. This fact adds a noise of typ. ±30ppm which has to be considered in terms of accuracy. Of principle measurement is the measured value of CO 2 concentration depends on the value of air pressure - altitude at the installation site. For this reason, it is suitable for accurate measurement to set the altitude of the installation site by TSensor software. After power up there is internal check in progress and takes about 20 s. During this time LCD display shows (----) instead of CO 2 concentration value. Parameter setting description is into chapter Regulator setting change part of measurement unit at page

12 7.3. Actual regulator preset measurement part It is NOT possible to make any changes of Ethernet services, for their setting see chapter Regulator configuration Ethernet interface at page 19. If output relay alarm condition configuration is made using Modbus protocol, keyboard is blocked for this time. During this configuration is a word bloc shown in the display. It is possible to display actual regulator preset on its LCD display by pressing of key. LCD shows information about Relay1 and then Relay2 setting step by step. Information about Relay1 are indicated with symbol, for Relay2 with symbol (at right top corner of LCD). It is possible to edit parameters after pressing SET key and entering of correct password PASS - see chapter Change of Password for setting through keys (PASS) at page 16. Following examples are for Relay1 setting, similarly are displayed values for Relay2. Pressing of ESC key ends this mode and switch to actual value displaying, the same occur if more than 20 s is not pressed any key Value assigned to output relay None, relay is still off Temperature at C Relative humidity Computed value dew point temperature CO 2 concentration Far condition 0 Far condition 1 FAR0 far condition 0 : after device s power on the relay is open FAR1 far condition 1 : after device s power on the relay is close If far condition is assigned to output relay, then there is possible to change the output relay status by Modbus communication protocol only. See chapter Modbus protocol at page When close output relay High limit HI the relay close when measured value exceeds preset high limit for longer time than preset delay time. Relay goes open when measured value decrease under high limit value minus the hysteresis value. See example. 12

13 High limit HI Delay [s] Hysteresis Low limit Lo the relay close when measured value falls below preset low limit for longer time than preset delay time. Relay goes open when measured value exceeds low limit value plus the hysteresis value. See example. Low limit Lo Delay [s] Hysteresis 7.4. Regulator setting change part of measurement unit Setting with PC and TSensor software User s software TSensor is available free to download at web page. It provides setting of all regulator parameters. Run the TSensor program and follow the program instructions. Regulator includes hardware write protection of internal setting (except of Ethernet setting which is protected by password), new setting is possible to write only while: 13

14 1. during write period press SET key do requested setting in TSensor software, press SET key on regulator and keep it down, then click on the button Save Changes into TSensor software and after end of write release SET key, or 2. jumper placed nearby keys is closed (jumper is accessible after demounting of four screws in the corners of the box and removing the lid, don t confuse with jumper nearby Ethernet connector!). This jumper is suitable e.g. until device adjustment is in process and regulator is placed into calibration box and keys are not accessible. Don t forget to remove (open) jumper after procedure finish (restore write protection) TSensor software supports to make the adjustment of the regulator too. This procedure is described at file Calibration manual.pdf which is installed commonly with the software Setting with using regulator keys If Actual regulator preset is displayed, it is possible to enter into edit mode and edit displayed value by pressing SET key. Then you are asked for valid password PASS. You can edit selected value if right password is entered. During value editing there is range check executed and edited value is still compared with limits for corresponding value (range). If inserted value is higher or lower then edited number is automatically changed to its maximum / minimum value for possible range see chapter Technical parameters at page 26. Value can be changed with using and keys. Edited value is switched in round -9, -8, -7, -2, -1, 0, 1, 2, 8, 9. To edit next number digit press SET key, for moving back to previous digit press ESC key. Edited value is stored by next SET key pressing. It is possible to cancel editing by pressing ESC key if necessary. If valid password is once inserted right, then there is possible to edit next items without asking for password insertion again, till Actual regulator preset is left (till actual measured values are shown). With new entering into edit mode it is necessary to enter Password again. Default password setting is preset from manufacturer to 0000, password change is possible into Extended setting. During edit mode regulator still works and changes are valid immediately after its storing it is not necessary to restart regulator Extended setting mode During regulator operation it is possible to change parameters available through Actual regulator preset only (see chapter Actual regulator preset measurement part at page 12). Rest of regulator parameters are available through Extended setting mode. In this mode regulator does NOT communicate, does NOT do any measurements and does NOT service output relays. To leave this mode press ESC key and open jumper nearby keys. To enter into extended setting mode do following steps: 1. disconnect power supply 2. demount four screws in the corners of the box and remove the lid 3. closed jumper placed nearby keys (don t confuse with jumper nearby Ethernet connector 4. press and keys together and keep them down 5. connect power supply to regulator you should see message SEL on the top line of LCD and on the bottom line you should see number of Firmware version (e.g. 0401) 6. release and keys you are into Extended setting mode now Use and keys to inspect each items. If you want to change some shown item then press SET key, item starts blink. Now you can edit setting with using and keys. To store preset value press SET key. Press ESC key to leave editing (changing) without save last stored value is kept. 14

15 Acoustic alarm assign to Relay1 (Relay2) acoustic indication of Relay1 is OFF close of Relay1 contact starts acoustic indication acoustic indication of Rela 2 is OFF close of Relay2 contact starts acoustic indication Acoustic alarm deactivation activated acoustic alarm is possible to deactivate by pressing ESC key acoustic alarm is still activated for all time and it is impossible to deactivate it Relay response for error Regulator continuously checks its state during operation. In case error of assigned value measurement is found then output relay: stays unchanged (in previous status) Relay1 switch OFF Relay1 switch On stays unchanged (in previous status) Relay2 switch OFF Relay2 switch On password setting 15

16 Change of Password for setting through keys (PASS) This item shows actual password setting. It is possible to change it after SET key pressing. It is number from range to Temperature unit choice It is possible to measure temperature at C or F. There is shown preset unit. It is possible to change it after SET key pressing. preset to C preset to F CO 2 measurement mode selection This item provides to choice if measured value is displayed and read in SLOW or FAST mode. FAST mode provides last measured value without averaging; this means that no software filter is used for calculating the output value. SLOW mode provides value averaged from last 11 FAST measured values. averaged value SLOW mode current value without averaging FAST mode CO 2 zone level indication setup Whole measuring range can be divided into three areas. Each active area there is indicated by green, yellow or red LED depends on actual measured value. It is done by two boundary limits setting. YELL limit sets boundary between green and yellow indication. It means that if actual measured value is lower than YELL limit, there is green LED active. If actual measured value is higher than YELL limit, then there is yellow LED active. Yellow LED lights until actual measured value exceeds RED limit. If actual value is higher than RED limit, red LED is active. If you don t want to use this indication then set YELL limit to 0. YELLOW limit setting RED limit setting 16

17 Show temperature at LCD display This item provides to choice if actual measured temperature may be displayed at LCD display or not. It is possible to change it after SET key pressing. show value on LCD don t show value on LCD Show relative humidity at LCD display This item provides to choice if actual measured relative humidity may be displayed at LCD display or not. It is possible to change it after SET key pressing. show value on LCD don t show value on LCD Show computed value at LCD display This item provides to choice if actual computed value may be displayed at LCD display or not. There is shown the name of computed value on the top LCD line. It is possible to change it after SET key pressing. show value on LCD don t show value on LCD Show CO 2 concentration at LCD display This item provides to choice if CO 2 value may be displayed at LCD display or not. It is possible to change it after SET key pressing. show value on LCD don t show value on LCD 17

18 Computed value selection It shows the actually selected computed value name. It is possible to change it after SET key pressing. There is possible choice one of the following computed values: dew point temperature absolute humidity mixing ratio specific humidity specific enthalpy 7.5. Restore to Factory default measurement part This item provides regulator restoring to factory setting. Press SET key, select YES and confirm it by pressing of SET key. It reset regulator parameters to following values: Value assigned to Relay1 and Relay2: none Password for setting through keys (PASS): 0000 Display: on Temperature unit: C Computed value preset: dew point temperature Relay response for error: stay unchanged at previous condition Acoustic alarm: off restore to factory default 18

19 7.6. Regulator configuration Ethernet interface The Ethernet configuration is performed by TSensor software 1 or Telnet setup. Setting through the Telnet is described in separated document. Access to the Setup can be protected by a password. TSensor program you can find on web or on the installation CD. This program is free for use and supports firmware update. The newest firmware is available at web pages too Alarms Ethernet interface Analogue values It is possible to set an upper limit, lower limit, hysteresis and time delay to each measured value. Figure shows a temperature curve with some specified upper limit (temp_limit_high) and hysteresis. At point 1 temperature exceeds the limit. From that moment a time delay is counted (time_delay) after which an alarm is set. Because at point 2 the temperature dropped below the limit value (temp_limit_high) before the time delay expired, alarm was not set. At point 3 the temperature again exceeded the limit, and because it did not drop below the limit value (temp_limit_high) before the time delay ended, the alarm was set at point 4. At this moment the alarm s and traps are sent, if they are enabled, and the alarm flag is set (the flag is set when the alarm is active and reset when inactive). The state of the flag can be found on the WWW pages or via Modbus or the information console. The alarm lasted to point 5, where the temperature dropped below the limit value given by the adjusted hysteresis (hysteresis). For other measured values the principle of alarm activity is analogical. An alarm report is always sent right after an alarm appears. The device memorizes sent alarm reports of current alarms while the power is connected. In case of power disconnection or a reset of the device (e.g. by modification of configuration) a new alarm evaluation is performed and new alarm reports are sent again, if any. It is possible to set the alarm parameters via telnet, Modbus protocol or a SNMPv1 protocol, TSensor program. Detailed description of setting via these protocols can be found in chapters informing about particular services. 1 In telnet some settings are not allowed (display settings, computed value selection), see chapter

20 7.8. Factory default Ethernet interface This procedure describe how set Ethernet interface of device to factory defaults (new IP address: , mask: ). 1. power off device 2. remove device cover 3. close jumper near the Ethernet interface 4. power on the device 5. wait approximately 15s 6. open jumper (remove shorting link) 7. close device cover 8. Communication protocols 8.1. Modbus protocol The device contains support for the Modbus TCP protocol to communicate with control systems. The port is set to 502. Port 502 enables full access, i.e. both read and write operations are supported. Access to port can be disabled in the Setup. Maximal number of client transaction is set to 1. Supported Modbus commands: Command Code Description Read multiple register(s) 0x03 Reads 16 bit register(s) Write multiple register(s) 0x10 Writes 16 bit register(s) Modbus registers of regulator: Variable Unit Format Address Address [hex] [dec] Status measured temperature C, F Int*10 0x r measured relative humidity (RH) % Int*10 0x r computed value (CV) CV depend Int*10 0x r CO 2 concentration displayed on LCD ppm Int 0x r device serial number Hi - BCD 0x r device serial number Lo - BCD 0x r Relay1 status [0/1] - Int 0x003B 59 r Relay2 status [0/1] - Int 0x003C 60 r far Relay1 control (see below) - Int 0x r/w [0 relay open, 1 relay closed] far Relay2 control (see below) - Int 0x r/w [0 relay open, 1 relay closed] CO 2 concentration FAST mode value ppm Int 0x r CO 2 concentration SLOW mode value ppm Int 0x r status word (described below) - Int 0x r firmware version Hi - BCD 0x r firmware version Lo - BCD 0x r lower limit for temperature C, F Int*10 0x r/w upper limit for temperature C, F Int*10 0x r/w 20

21 Variable Unit Format Address Address [hex] [dec] Status lower limit for humidity % Int*10 0x r/w upper limit for humidity % Int*10 0x r/w lower limit for computed value CV depend Int*10 0x r/w upper limit for computed value CV depend Int*10 0x r/w temperature hysteresis C, F Int*10 0x r/w temperature time delay s uint 0x r/w RH hysteresis % Int*10 0x r/w RH time delay s uint 0x500A r/w computed value hysteresis CV depend Int*10 0x500B r/w computed value time delay s uint 0x500C r/w temperature alarm status - ASCII a) 0x500D r RH alarm status - ASCII a) 0x500E r computed value alarm status - ASCII a) 0x500F r lower CO 2 concentration limit ppm Int 0x r/w upper CO 2 concentration limit ppm Int 0x r/w CO 2 concentration hysteresis ppm Int 0x r/w CO 2 concentration limit status - ASCII a) 0x r CO 2 concentration time delay s uint 0x r/w Relay1 alarm status - ASCII b) 0x r Relay2 alarm status - ASCII b) 0x r Legend: r register is designed for read w register is designed for write Int*10 register is in format of integer*10 Int*X register is in format of integer*10, int*100, int*1000 depend on type BCD register is in format of BCD uint register is at range of ASCII character, where: a) Temperature, RH, computed value, pressure alarm status no no alarm lo value is bigger than specified upper limit hi value is lower than specified lower limit b) Relay alarm status: op no alarm cl relay is closed, alarm is signaled Status word: 16b value return, bite description: Bit0 0/1 jumper open/closed Bit3 0/1 Relay1 open/closed Bit4 0/1 Relay2 open/closed Bit5 0/1 internal acoustic alarm status Far relay control: open/close relay through Modbus protocol. Before using remote relay control option is necessary setup FAR0 or FAR1 to the relay. FAR0 remote relay control, after device reboot relay is open FAR1 remote relay control, after device reboot Output relay alarm condition configuration: 21

22 8.2. SMTP In case of exceeding adjusted limits of measured values the device can send s to maximum of three addresses. It is necessary to set your SMTP server address (IP address, authentication, etc.) for correct function of sending. If limits of several measured values are exceeded a special alarm is sent for each alarm state. Dummy address sensor@[device IP address] is displayed as a sender of the . It is not possible to reply to this address. In the Subject field of the message the sentence Alarm [Description of the device] is displayed or Test message [Description of the device] in the case of sending a test SNMPv1 By means of the SNMPv1 protocol it is possible to find currently measured values, read and set parameters concerning alarms. In case of alarm activation, warning message (a trap) can be sent to specified addresses. By means of the SNMPv1 protocol it is also possible to display history of last 100 measured values. For read and write the device communicates via UDP port 161. Traps are sent via port UDP port 162. Sending of traps can be disabled in the Setup. The following traps sent 0/0 device restart 1/0 testing trap 1/1 SNTP time synchronization error 1/2 Ethernet firmware was uploaded 1/3 1/5 SOAP communication error 1/6 1/8 sending error 1/9 Configuration changed via SNMP or Modbus 6/3 6/55 report on a measured value being outside of the limits or a return of the measured value to the limits For the correct function of the SNMPv1 server it is necessary to store the MIB table Hx5xx.mib and RFC-1213.mib to the MIB client. The path to the device is then: iso.org.dod.internet.private.enterprises.comet.products.hx5xx MIB tables are available on the installation CD in the MIB directory. Password for a read operation is set by the manufacturer to public, password for write is set to private. These passwords may be changed in the setup. History By means of the SNMPv1 protocol it is possible to display history of the last 100 measured values, stored in adjusted time interval. This interval is set by configuration program. If a value has not been measured yet or an error was detected the value is 9999, or -9999, if pressure is measured. The history is erased after each restart of the device. Restart occurred if device configuration is changed via keyboard or TSensor software. 22

23 8.4. WWW The device supports display of measured values, adjusted limits and alarm states on its WWW pages. The address of the WWW pages is identical with its IP address. It is possible to upload self-made web pages to device. Example: The device has an IP address Enter to the browser address field and confirm it with the Enter key. WWW pages have adjustable automatic refresh interval. The manufacturer sets it to 60 seconds. The value can be modified in the setup in a range of s. If the device has WWW pages display disabled screen with message Access denied SNTP The device allows time synchronization with SNTP server. The time synchronization is set to every 8 hours. If the time synchronization failed in next three hours, SNTP trap, and Syslog message will be sent Syslog protocol Device allows send messages to selected Syslog server (UDP protocol, port 514). Events are described below. Event device restart test message alarm occurred SNTP connection error write to device via Modbus, SNMP firmware was changed alarm is down SOAP server communication error sending error Text Device restart Testing message Alarm NTP connection error Settings changed Firmware uploaded Clearing SOAP SOAP Device allows sending SOAP messages with measured values to user defined remote web server in preset time intervals s. If the device cannot establish connection with the web server in the whole delay interval, device sends trap 1/3 1/5. How to configure sending SOAP messages example: SOAP enable: Yes Target web page: my.hosting.nl/soap/server.php SOAP server IP address: Source port: 0 (never set to 80, causes it web server collision) Destination port: 80 (http servers usually listens at this port) Sending interval: 10 23

24 9. What to do when I forgot the IP address of the device Finding the device IP address IP address is set to the value by the manufacturer. If you changed it and forgot the new IP address, run the TSensor program and press the Find button. In a new window all sensors will be show. It is not possible to connect to the device from a LAN In the Find device window is only IP and MAC address displayed The next information is displayed as N/A. This problem will be occurred, when the device IP is set to another LAN. In TSensor program choose Find device/change IP address. Follow the program instruction. The sensor IP address in Find device window is not displayed In TSensor program select Find device/help my device Wasn t found! Follow the program instruction. Finding the MAC address The MAC address is a unique address of a device which is necessary to be known e.g. in case when there are several devices connected to the network. MAC address is on device label. It is not possible to find meter after manual MAC enter In TSensor program select Find device/help my device Wasn t found. In this select Set IP to ARP only. Into device MAC address enter the meters MAC address (e.g A-84-F0-80) and press the Set IP button. Open telnet to the IP address you assigned to the device MAC address by running a telnet command telnet [IP_address_assigned_to_MAC_address] 9999 and confirm with the Enter key. Choose 0 - Global Settings, set the meters IP address, clear the gate IP, no. of net mask set to 0. Pres the Enter key, until you are not back into a menu. Press - 9 Save and Exit. The connection will be closed. Now you can connect to meter by the TSensor program. LCD display is Off check if power supply is connected properly disconnect and connect the power supply - watch the display at the moment of connecting the power. If all LCD segments light for 1 second and go out again, the display is turned off by the software 24

25 10. Error States of the device Device continuously checks its state during operation. In case error is found LCD displays corresponding error code: Error 0 - first line of LCD displays Err0. Check sum error of stored setting inside device s memory. This error appears if incorrect writing procedure to device s memory occurred or if damage of calibration data appeared. At this state device does not measure and calculate values. It is a serious error, contact distributor of the device to fix. Error 1 - measured or calculated value (except concentration of CO 2 ) is over upper limit of allowed full scale range. There is a reading Err1 on LCD display. Value read from the device is This state appears in case of: Measured temperature is higher than approximately 600 C (i.e. high non-measurable resistance of temperature sensor, probably opened circuit). Relative humidity is higher than 100%, i.e. damaged humidity sensor, or humidity calculation of humidity is not possible (due to error during temperature measurement). Computed value calculation of the value is not possible (error during measurement of temperature or relative humidity or value is over range). The value of CO 2 concentration 9999 ppm is correct value! Error 2 - there is a reading Err2 on LCD display. Measured or calculated value is below lower limit of allowed full scale range or CO 2 concentration measurement error occurred. Value read from the device is This state appears in case of: Measured temperature is lower than approximately -210 C (i.e. low resistance of temperature sensor, probably short circuit). Relative humidity is lower than 0%, i.e. damaged sensor for measurement of relative humidity, or calculation of humidity is not possible (due to error during temperature measurement). Measured value of CO2 concentration is outside the range 0 to 2000 (10000) ppm Computed value calculation of computed value is not possible (error during measurement of temperature or relative humidity). Error 3 - there is a reading Err3 on LCD display upper line. Error of internal A/D converter appeared (converter does not respond, probably damage of A/D converter). At this state device does not measure temperature and relative humidity and computed values are not calculated. This error does not affect CO 2 concentration measurement. It is a serious error, contact distributor of the device. Error 4 - there is a reading Err4 on LCD display. It is internal device error during CO 2 concentration sensor initialization. Under this condition device does not measure concentration of CO 2. Value read from device is (concentration of CO 2 ). CO 2 sensor is probably damaged. It is a serious error, contact distributor of the device. Error 5, 6 - there is problem with assigned value to output relay, there is some wrong setting (mismatch). This error appears if incorrect writing procedure to device s memory occurred. Error 9 - inserted password is not valid, there is shown for short time message Err9 on LCD display. 25

26 11. Readings on LCD display C, F reading next to this symbol is measured temperature or error state of value %RH reading next to this symbol is measured relative humidity or error state of value CO2 ppm reading next to this symbol is measured concentration of CO 2 or error state of value. Blinking symbol CO2 ppm on LCD indicates internal auto calibration of CO 2 sensor running. It runs automatically each 24 hours and takes about 90 s. C / F DP reading next to this symbol is calculated dew point temperature or error state of value g/m 3 g/kg reading next to this symbol is calculated absolute humidity or error state of value reading next to this symbol is calculated specific humidity or mixing ratio (depends on device setting) or error state of value 3 this symbol is on if jumper is closed If specific enthalpy is selected, there is shown only value (number) without corresponding unit. 12. Preventive maintenance and calibration Pay heed to recommended calibration interval. Do not subject the device to mechanical stress. Recommended calibration intervals: AT-VLS-104DE 5 years (CO 2 ) AT-VLS-101DE 5 years (CO 2 ) AT-VLS-102DE 5 years (CO 2 ), 1 year (relative humidity), 2 years (temperature) AT-VLS-106DE 5 years (CO 2 ), 1 year (relative humidity), 2 years (temperature) 13. Technical specification Technical parameters Common parameters Power voltage: 9 to 30 V DC Power consumption:, Power connector: 1W during normal operation 4W for 50ms with 15 s period coaxial connector, diameter 5,5 x 2,1 mm, (+) internal contact Measuring interval: temperature, relative humidity s concentration of CO s Display switching interval: 4 s (when more than two values are displayed) Communication with computer: Ethernet connection (RJ-45 connector) Relay outputs: Amount: 2 Maximal voltage: 50 V Maximal current: 2A Maximal power: 60 VA Relays contact is not designed for direct control of line voltage! (relay contact parameters: max 220Vdc, 125Vac, 2A, 60 W, 62.5 VA) EMC: EN , EN 55011, EN

27 AT-VLS-104DE - CO 2 regulator Concentration of CO 2 : Accuracy:: ± (100 ppm + 5 % of measuring value) at 25 C (77 F) and 1013 hpa Range: 0 to ppm Temperature dependence: typ. 2 ppm CO 2 / ºC in the range 0 to 50 ºC (32 to 122 F) Long term stability: typ. 20 ppm / year Resolution: 1 ppm Response time: t90 < 195 s in SLOW measurement mode t90 < 75 s in FAST measurement mode AT-VLS-101DE - CO 2 regulator Concentration of CO 2 : Accuracy:: ± (50 ppm + 2 % of measuring value) at 25 C (77 F) and 1013 hpa Range: 0 to ppm Temperature dependence: typ. 2 ppm CO 2 / ºC in the range 0 to 50 ºC (32 to 122 F) Long term stability: typ. 20 ppm / year Resolution: 1 ppm Response time: t90 < 195 s in SLOW measurement mode t90 < 75 s in FAST measurement mode AT-VLS-102DE temperature, relative humidity and CO 2 regulator Temperature: Accuracy: ± 0,4 C (±0,7 F) Range: -30 to +60 C (-22 to 140 F) Resolution: 0,1 C (0,2 F) Relative humidity: Accuracy: ± 2,5 %RH from 5 to 95 %RH at 23 C (73,4 F) Range: 0 to 100 %RH, temperature compensated Resolution: 0,1 %RH Concentration of CO 2 : Accuracy:: ± (50 ppm + 2 % of measuring value) at 25 C (77 F) and 1013 hpa Range: 0 to 2000 ppm Temperature dependence: typ. 2 ppm CO 2 / ºC in the range 0 to 50 ºC (32 to 122 F) Long term stability: typ. 20 ppm / year Resolution: 1 ppm Measuring temperature and humidity range is limited in accordance with the graph below Response time measurement of temperature and relative humidity with stainless steel mesh sensor cover (F5200B) and bronze sensor cover (F selectable option), air flow approximately 1 m/s: temperature: t90 < 6 min (temperature step 20 C (36 F)) relative humidity: t90 < 30 s (humidity step 65 %RH, constant temperature) Response time measurement of CO 2 concentration: t90 < 195 s in SLOW measurement mode t90 < 75 s in FAST measurement mode 27

28 AT-VLS-106DE temperature, relative humidity and CO 2 regulator Temperature: Accuracy: ± 0,4 C (±0,7 F) Range: -30 to +105 C (-22 to 221 F) Resolution: 0,1 C (0,2 F) Relative humidity: Accuracy: ± 2,5 %RH from 5 to 95 %RH at 23 C (73,4 F) Range: 0 to 100 %RH, temperature compensated Resolution: 0,1 %RH Concentration of CO 2 : Accuracy:: ± (100 ppm + 5 % of measuring value) at 25 C (77 F) and 1013 hpa Range: 0 to ppm Temperature dependence: typ. 2 ppm CO 2 / ºC in the range 0 to 50 ºC (32 to 122 F) Long term stability: typ. 20 ppm / year Resolution: 1 ppm Measuring temperature and humidity range is limited in accordance with the graph below Response time measurement of temperature and relative humidity with stainless steel mesh sensor cover (F5200B) and bronze sensor cover (F selectable option), air flow approximately 1 m/s: temperature: t90 < 6 min (temperature step 20 C (36 F)) relative humidity: t90 < 30 s (humidity step 65 %RH, constant temperature) Response time measurement of CO 2 concentration: t90 < 195 s in SLOW measurement mode t90 < 75 s in FAST measurement mode Relative humidity and temperature restriction 28

29 Value computed from measured relative humidity and temperature Dew point temperature Range: -60 to +80 C (-76 to 176 F) Accuracy: ±1,5 C (±2,7 F) at ambient temperature T<25 C (77 F) and relative humidity RH >30%, for more details see graphs below Absolute humidity Range: 0 to 400 g/m 3 Accuracy: ±1,5 g/m 3 at ambient temperature T < 25 C (104 F), for more details see graph below 29

30 Specific humidity 2 Accuracy: ±2g/kg at ambient temperature T < 35 C (95 F) Range: 0 to 550 g/kg Mixing ratio 2 Accuracy: ±2g/kg at ambient temperature T < 35 C (95 F) Range: 0 to 995 g/kg Specific enthalpy 2 Accuracy: ± 3kJ/kg at ambient temperature T < 25 C (77 F) Range: 0 to 995 kj/kg 3 The values computed from ambient temperature and relative humidity including their accuracy Operating conditions Operating temperature range: electronics AT-VLS-104DE, AT-VLS-106DE: electronics AT-VLS-101DE, AT-VLS-102DE: measuring end of stem AT-VLS-102DE: CO 2 probe AT-VLS-104DE, AT-VLS-106DE RH+T probe AT-VLS-106DE: -30 to +80 C (-22 to 176 F) -30 to +60 C (-22 to 140 F) -30 to +80 C (-22 to +176 F) -40 to +60 C (-40 to +140 F) -30 to +105 ºC (-22 to +221 ºF) It is recommended to switch off the LCD display at ambient temperatures above 70 C around electronics. Operating humidity range: AT-VLS-104DE, AT-VLS-106DE: 0 to 100 % RH (no condensation) AT-VLS-101DE, AT-VLS-102DE: 5 to 95 % RH (no condensation) Operating barometric pressure range: 850 to 1100 hpa Protection: AT-VLS-104DE IP30 (electronics), IP65 (CO 2 probe) AT-VLS-101DE IP30 (electronics) AT-VLS-102DE IP30 (electronics), IP40 (measuring end of stem) AT-VLS-106DE IP30 (electronics), IP65 (CO 2 probe), IP40 (RH+T probe) Working position: AT-VLS-104DE, AT-VLS-106DE: negligible AT-VLS-101DE: with cable glands upwards AT-VLS-102DE: with sensor cover downwards Not allowed manipulations: It is not allowed to operate the device under conditions other than specified in technical parameters. Devices are not designed for locations with chemically aggressive environment. Temperature and humidity sensors must not be exposed to direct contact with water or other liquids. It is not allowed to remove the sensor cover to avoid any mechanical damage of the sensors. 2 This value depends on the atmospheric pressure. For computing is used constant value stored in device memory. Default value preset by manufacturer is 1013hPa and can be changed by user s software. 3 This maximum is reached under conditions about 70 C/100%RH or 80 C/70%RH 30

31 Storage conditions: temperature: -40 to +60 C (-40 to 140 F) relative humidity: 5 to 95 % RH (no condensation) atmospheric pressure: 700 a 1100 hpa Dimensions: see dimensional drawings Weight: approximately AT-VLS-104DE/1m probe 420 g AT-VLS-104DE/2m probe 450 g AT-VLS-104DE/4m probe 510 g AT-VLS-101DE 330 g AT-VLS-102DE 350 g AT-VLS-106DE/1m probe 500 g AT-VLS-106DE/2m probe 570 g AT-VLS-106DE/4m probe 710 g Material of the case: ABS End of operation Device itself (after its life) is necessary to liquidate ecologically! Technical support and service The adjustment procedure is described at file Calibration manual.pdf. Technical support and service is provided by distributor. For contact see warranty certificate. 14. Appendix A Connection of external power relay Coil data chart of external power relay: nominal voltage : max 50V nominal power: max 60VA current: max 2A 31

T5540. Programmable transmitter of temperature, relative humidity, CO 2 and other derived humidity values with Ethernet connection T6540

T5540. Programmable transmitter of temperature, relative humidity, CO 2 and other derived humidity values with Ethernet connection T6540 CO 2 concentration transmitter with Ethernet connection T5540 Programmable transmitter of temperature, relative humidity, CO 2 and other derived humidity values with Ethernet connection T6540 Instruction

More information

Temperature and humidity regulator H3020 H3021 H3023 H3027. Instruction Manual

Temperature and humidity regulator H3020 H3021 H3023 H3027. Instruction Manual Temperature and humidity regulator H3020 H3021 H3023 H3027 Instruction Manual Table of content 1. GENERAL SAFETY RULES... 3 2. GENERAL DESCRIPTION... 4 3. REGULATOR MOUNTING AND CONNECTION... 4 4. DESCRIPTION

More information

Rack mount environment monitor

Rack mount environment monitor Rack mount environment monitor H3531R H4531R H7531R Monitoring of temperature, humidity, barometric pressure and other derived humidity values with Ethernet interface Instruction Manual Table of content

More information

AT-VLI-102DRS. Manual. ATAL B.V. Ampèrestraat NL-1446 TR PURMEREND. Postbus 783 NL-1440 AT PURMEREND T (+31) F (+31)

AT-VLI-102DRS. Manual. ATAL B.V. Ampèrestraat NL-1446 TR PURMEREND. Postbus 783 NL-1440 AT PURMEREND T (+31) F (+31) AT-VLI-102DRS Manual ATAL B.V. Ampèrestraat 35-37 NL-1446 TR PURMEREND Postbus 783 NL-1440 AT PURMEREND T (+31) 0299 630 610 F (+31) 0299 630 611. E info@atal.nl I www.atal.nl Instruction Manual The transmitters

More information

Intelligent single channel temperature transducer with Ethernet connection P8511

Intelligent single channel temperature transducer with Ethernet connection P8511 Intelligent single channel temperature transducer with Ethernet connection P8511 Intelligent four channel temperature transducer with Ethernet connection P8541 Intelligent temperature meter with Ethernet

More information

Temperature, humidity and pressure regulator. with RS485 serial output H0430 H3430 H3431 H3433 H3437 H4431 H7430 H7431. Instruction Manual

Temperature, humidity and pressure regulator. with RS485 serial output H0430 H3430 H3431 H3433 H3437 H4431 H7430 H7431. Instruction Manual Temperature, humidity and pressure regulator with RS485 serial output H0430 H3430 H3431 H3433 H3437 H4431 H7430 H7431 Instruction Manual 1. GENERAL SAFETY RULES...3 2. GENERAL DESCRIPTION...4 3. REGULATOR

More information

Programmable transmitter of temperature, relative humidity and other derived humidity values with 0 to 10 V outputs Instruction Manual

Programmable transmitter of temperature, relative humidity and other derived humidity values with 0 to 10 V outputs Instruction Manual T0210 TRANSMITTER Programmable transmitter of temperature, relative humidity and other derived humidity values with 0 to 10 V outputs Instruction Manual Instruction manual for use of T0210 transmitter

More information

Intelligent pressure meter with Ethernet connection T2514

Intelligent pressure meter with Ethernet connection T2514 Intelligent pressure meter with Ethernet connection T2514 Intelligent temperature, relative humidity meter with Ethernet connection With calculation of dew point temperature, absolute humidity, specific

More information

Programmable transmitter of temperature, relative humidity and other derived humidity values with RS485 serial output Instruction Manual

Programmable transmitter of temperature, relative humidity and other derived humidity values with RS485 serial output Instruction Manual TRANSMITTER T3413, T3417 Programmable transmitter of temperature, relative humidity and other derived humidity values with RS485 serial output Instruction Manual Instruction Manual for use of temperature

More information

Temperature, humidity and pressure regulator. with RS485 serial output H0430 H3430 H3431 H3433 H3437 H4431 H7430 H7431. Instruction Manual

Temperature, humidity and pressure regulator. with RS485 serial output H0430 H3430 H3431 H3433 H3437 H4431 H7430 H7431. Instruction Manual Temperature, humidity and pressure regulator with RS485 serial output H0430 H3430 H3431 H3433 H3437 H4431 H7430 H7431 Instruction Manual Table of content 1. GENERAL DESCRIPTION... 5 2. REGULATOR MOUNTING

More information

T3311, T3313, T3411 T7310, T7410. Instruction Manual

T3311, T3313, T3411 T7310, T7410. Instruction Manual Programmable transmitter of temperature, relative humidity and other derived humidity values T3311, T3313, T3411 Programmable transmitter of atmospheric pressure, temperature, relative humidity and other

More information

TRANSDUCER T4311, T4411

TRANSDUCER T4311, T4411 TRANSDUCER T4311, T4411 Programmable temperature transducer for RTD Pt1000 sensor with serial output RS232 and RS485 Instruction manual Instruction Manual for use of transducer: T4311 (RS232), T4411 (RS485)

More information

T2314, T2414. Instruction Manual

T2314, T2414. Instruction Manual Atmospheric pressure transmitter T2314, T2414 with RS232 / RS485 serial output Instruction Manual Instruction Manual Device type Pressure Output Galvanic isolated output T2314 RS232 - T2414 RS485 Device

More information

T2314, T2414. Instruction Manual

T2314, T2414. Instruction Manual Atmospheric pressure transmitter T2314, T2414 with RS232 / RS485 serial output Instruction Manual Instruction Manual Device type Pressure Output Galvanic isolated output T2314 RS232 - T2414 RS485 Device

More information

T2214. Instruction Manual

T2214. Instruction Manual Programmable atmospheric pressure transmitter T2214 with 0 to 10 V output Instruction Manual Instruction manual for use of T2214 device Device is designed for measurement of atmospheric pressure at hpa,

More information

Instruction Manual. T3110 T3110L T3110Ex

Instruction Manual. T3110 T3110L T3110Ex www.cometsystem.cz Instruction Manual T3110 T3110L T3110Ex Programmable transmitter of temperature, relative humidity and other calculated humidity values with 4-20 ma outputs Copyright: COMET System,

More information

Programmable temperature transducer from Pt1000 sensor to current loop 4-20 ma Instruction Manual

Programmable temperature transducer from Pt1000 sensor to current loop 4-20 ma Instruction Manual T4111 TRANSDUCER Programmable temperature transducer from Pt1000 sensor to current loop 4-20 ma Instruction Manual Instruction manual for use of T4111 transducer Transducer is designed for temperature

More information

T3319, T3419 T7311, T7411. Instruction Manual

T3319, T3419 T7311, T7411. Instruction Manual Programmable transmitter of temperature, relative humidity and other derived humidity values T3319, T3419 Programmable transmitter of atmospheric pressure, temperature, relative humidity and other derived

More information

Programmable indoor transmitter of temperature T0318, T0418

Programmable indoor transmitter of temperature T0318, T0418 Programmable indoor transmitter of temperature T0318, T0418 Programmable indoor transmitter of temperature, relative humidity and other derived humidity values T3318, T3418 Programmable indoor transmitter

More information

EPND-4S. Gebruikershandleiding/Manual. ATAL B.V. Ampèrestraat NL-1446 TR PURMEREND. Postbus 783 NL-1440 AT PURMEREND

EPND-4S. Gebruikershandleiding/Manual. ATAL B.V. Ampèrestraat NL-1446 TR PURMEREND. Postbus 783 NL-1440 AT PURMEREND EPND-4S Gebruikershandleiding/Manual ATAL B.V. Ampèrestraat 35-37 NL-1446 TR PURMEREND Postbus 783 NL-1440 AT PURMEREND T (+31) 0299 630 610 F (+31) 0299 630 611 E info@atal.nl I www.atal.nl 1 Content

More information

EPD-TRH-POE. Manual. ATAL B.V. Ampèrestraat NL-1446 TR PURMEREND. Postbus 783 NL-1440 AT PURMEREND T (+31) F (+31)

EPD-TRH-POE. Manual. ATAL B.V. Ampèrestraat NL-1446 TR PURMEREND. Postbus 783 NL-1440 AT PURMEREND T (+31) F (+31) EPD-TRH-POE Manual ATAL B.V. Ampèrestraat 35-37 NL-1446 TR PURMEREND Postbus 783 NL-1440 AT PURMEREND T (+31) 0299 630 610 F (+31) 0299 630 611 E info@atal.nl I www.atal.nl Inhoudsopgave Introduction...

More information

TRANSMITTER T3311, T3411

TRANSMITTER T3311, T3411 TRANSMITTER T3311, T3411 Programmable relative humidity and temperature transmitter with serial output RS232 and RS485 With computing of dew point temperature, absolute humidity, specific humidity, mixing

More information

USER GIDE COMET SYSTEM

USER GIDE COMET SYSTEM COMET SYSTEM www.cometsystem.com Web Sensor T0510 Web Sensor T4511 Web Sensor T3510 Web Sensor T3511 Web Sensor T3511P Web Sensor T7510 Web Sensor T7511 Web Sensor T2514 USER GIDE Copyright: COMET System,

More information

USER GUIDE COMET SYSTEM

USER GUIDE COMET SYSTEM COMET SYSTEM www.cometsystem.com Web Sensor T0610 with PoE Web Sensor T4611 with PoE Web Sensor T3610 with PoE Web Sensor T3611 with PoE Web Sensor T7610 with PoE Web Sensor T7611 with PoE Web Sensor T7613D

More information

Monitoring of temperature, humidity, atm. pressure and CO 2. via Ethernet. with two-state inputs

Monitoring of temperature, humidity, atm. pressure and CO 2. via Ethernet. with two-state inputs Monitoring of, humidity, atm. pressure and via Ethernet Web Sensors of, humidity, atmospheric pressure and with two-state inputs and relay outputs high quality, accurate and stable sensors values computed

More information

Monitoring of temperature, humidity, atm. pressure and CO 2. via Ethernet. with two-state inputs

Monitoring of temperature, humidity, atm. pressure and CO 2. via Ethernet. with two-state inputs Monitoring of temperature, humidity, atm. pressure and CO 2 via Ethernet Web Sensors of temperature, humidity, atmospheric pressure and CO 2 with two-state inputs and relay outputs high quality, accurate

More information

Communication protocols description of. Hx4xx and Hx3xx regulators with RS485 and RS232 communication interface

Communication protocols description of. Hx4xx and Hx3xx regulators with RS485 and RS232 communication interface Communication protocols description of Hx4xx and Hx3xx regulators with RS485 and RS232 communication interface Copyright: COMET System, Ltd. It is prohibited to copy and edit this manual and make any changes

More information

USER GUIDE COMET SYSTEM

USER GUIDE COMET SYSTEM COMET SYSTEM www.cometsystem.cz Web Sensor T0510 Web Sensor T4511 Web Sensor T3510 Web Sensor T3511 Web Sensor T3511P Web Sensor T7510 Web Sensor T7511 Web Sensor T2524 USER GUIDE Copyright: COMET System,

More information

Temperature logger with internal sensor Instruction manual

Temperature logger with internal sensor Instruction manual LOGGER R0110 Temperature logger with internal sensor Instruction manual Manual for use of temperature logger R0110 Logger is designed for measurement and record of temperature from built-in internal temperature

More information

Temperature logger with display Instruction Manual

Temperature logger with display Instruction Manual LOGGER S0110 Temperature logger with display Instruction Manual Instruction manual for use of temperature logger S0110 Logger is designed for measurement and record of temperature from built-in internal

More information

EPND-T-INT-POE. Notice, installation and troubleshooting. ATAL B.V. Ampèrestraat NL-1446 TR PURMEREND. Postbus 783 NL-1440 AT PURMEREND

EPND-T-INT-POE. Notice, installation and troubleshooting. ATAL B.V. Ampèrestraat NL-1446 TR PURMEREND. Postbus 783 NL-1440 AT PURMEREND EPND-T-INT-POE Notice, installation and troubleshooting ATAL B.V. Ampèrestraat 35-37 NL-1446 TR PURMEREND Postbus 783 NL-1440 AT PURMEREND T (+31) 0299 630 610 F (+31) 0299 630 611 E info@atal.nl I www.atal.nl

More information

1. Short description. 2. Features. 3. Technical parameters

1. Short description. 2. Features. 3. Technical parameters 1. Short description TCW122B-RR is a remote relay control module with embedded WEB server for set up. The device has two digital inputs and two relays, with normally open and normally closed contacts.

More information

TEMPERATURE AND HUMIDITY TRANSDUCER P18 TYPE USER S MANUAL

TEMPERATURE AND HUMIDITY TRANSDUCER P18 TYPE USER S MANUAL TEMPERATURE AND HUMIDITY TRANSDUCER P18 TYPE USER S MANUAL 1 2 CONTENTS 1. APPLICATION... 5 2. BASIC REQUIREMENTS, OPERATIONAL SAFETY... 5 3. INSTALLATION... 5 3.1. Assembly...5 3.2. Electrical Connections...7

More information

Dual channel temperature logger with display Instruction Manual

Dual channel temperature logger with display Instruction Manual LOGGER S0122 Dual channel temperature logger with display Instruction Manual ie-log-s0122-05 Instruction manual for use of temperature logger S0122 Logger is designed for measurement and record of ambient

More information

Dual channel temperature logger with two voltage inputs 0-5V Instruction Manual

Dual channel temperature logger with two voltage inputs 0-5V Instruction Manual LOGGER S0541 Dual channel temperature logger with two voltage inputs 0-5V Instruction Manual Instruction Manual for use of S0541 logger Instrument is designed for measurement and record of temperature

More information

sensor, which compensates for ageing effects, is highly insensitive to pollution and offers outstanding long term stability.

sensor, which compensates for ageing effects, is highly insensitive to pollution and offers outstanding long term stability. USER S GUIDE EE800 - HVAC Room Transmitter for CO 2, Temperature and Relative Humidity GENERAL EE800 combines CO 2, temperature (T) and relative humidity (RH) measurement in one device with modern design.

More information

Multi Units Humidity/Temperature Transmitter. HygroViewer Model JW300 User Manual

Multi Units Humidity/Temperature Transmitter. HygroViewer Model JW300 User Manual Multi Units Humidity/Temperature Transmitter HygroViewer Model JW300 User Manual 1. Electrical Wired & Installation The power cord is a one-meter length, 22 AWG, 7 different colors for recognition. Please

More information

SELECTION TABLE OF TEMPERATURE, HUMIDITY, PRESSURE CO TRANSMITTERS Hxxxx

SELECTION TABLE OF TEMPERATURE, HUMIDITY, PRESSURE CO TRANSMITTERS Hxxxx SELECTION TABLE OF TEMPERATURE, HUMIDITY, PRESSURE CO TRANSMITTERS Hxxxx MEASURED VALUE / OUTPUT x Relay x Relay RS485 x Relay RS3 x Relay Ethernet temperature + 3 binary inputs H0430 fig. H4431 fig.1

More information

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26 H20.0.24.6C1-07 EASYBus-Sensor module for humidity temperature with option: selectable humidity display from version V3.2 Operating Manual EBHT 2R / UNI Content 1 INTENDED USE 2 2 GENERAL ADVICE 2 3 SAFETY

More information

COMET SYSTEM. Web Sensor P8510. Web Sensor P8511. Web Sensor P8541 USER GUIDE

COMET SYSTEM.  Web Sensor P8510. Web Sensor P8511. Web Sensor P8541 USER GUIDE COMET SYSTEM www.cometsystem.com Web Sensor P8510 Web Sensor P8511 Web Sensor P8541 USER GUIDE Copyright: COMET System, s.r.o. Is prohibited to copy and make any changes in this manual, without explicit

More information

COMET SYSTEM. Web Sensor P8510. Web Sensor P8511. Web Sensor P8541 USER GUIDE

COMET SYSTEM.   Web Sensor P8510. Web Sensor P8511. Web Sensor P8541 USER GUIDE COMET SYSTEM www.cometsystem.cz Web Sensor P8510 Web Sensor P8511 Web Sensor P8541 USER GUIDE Copyright: COMET System, Ltd. Is prohibited to copy and make any changes in this manual, without explicit agreement

More information

Connector for sensing cable

Connector for sensing cable HWg-WLD MANUAL ETHERNET 10/100 Mbps Status LED Yellow: Power & Mode Green: Link & Activity Connection cable 100 m max POWER input 5V DC supply Use the supplied power adapter SENSOR Connector for sensing

More information

HWg-STE HWg-STE PoE MANUAL

HWg-STE HWg-STE PoE MANUAL HWg-STE HWg-STE PoE MANUAL HWg-STE connections LED indicators Green: Power & Mode Yellow: Link & Activity SENSORS S1 and S2 ports for connecting temperature or humidity sensors. - Max. distance with 1

More information

Network Management Card. User Manual

Network Management Card. User Manual User Manual 1 Contents Contents 2 Chapter 1 Overview 3 1.1 NMC package contents 4 1.2 NMC CD Resources 4 1.3 Features 4 1.4 NMC Applications 5 Chapter 2 NMC parameters setting via serial COM port 6 2.1

More information

Dual channel temperature logger with two binary inputs and LCD display Instruction Manual

Dual channel temperature logger with two binary inputs and LCD display Instruction Manual LOGGER S0841 Dual channel temperature logger with two binary inputs and LCD display Instruction Manual Instruction Manual for use of S0841 logger Instrument is designed for measurement and record of temperature

More information

Digital thermo-hygro-barometer with external probe Manual for use

Digital thermo-hygro-barometer with external probe Manual for use COMMETER D4141 Digital thermo-hygro-barometer with external probe Manual for use Instruction manual for use of thermo-hygro-barometer COMMETER D4141 Instrument is designed for measurement and data logging

More information

with serial RS485/RS232 output

with serial RS485/RS232 output with serial RS485/RS232 output RS485 programmable sensors of temperature, humidity, atmospheric pressure and CO 2 with two-state inputs and relay outputs industry and interior design high quality, accurate

More information

DSTHM-2 COMBINED T AND RH DUCT TRANSMITTER. Mounting and operating instructions

DSTHM-2 COMBINED T AND RH DUCT TRANSMITTER. Mounting and operating instructions Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 4 OPERATIONAL DIAGRAMS 5 WIRING AND

More information

isma-b-mg-ip User Manual Global Control 5 Sp. z o.o. Poland, Warsaw

isma-b-mg-ip User Manual Global Control 5 Sp. z o.o. Poland, Warsaw isma-b-mg-ip User Manual Global Control 5 Sp. z o.o. Poland, Warsaw www.gc5.pl Table of content 1 Introduction... 4 1.1 Revision history... 5 1.2 Safety rules... 5 1.3 Technical specifications... 6 1.4

More information

Poseidon 4002 MANUAL

Poseidon 4002 MANUAL Poseidon 4002 MANUAL Poseidon 4002 MANUAL POWER input 12VDC supply (jack or terminals) INPUTS Binary inputs 1 6 (for contacts) OUTPUTS Two 50V rated switchover relay contacts ETHERNET 10 or 100/10 Mbps

More information

TOXALERT MODEL AIR 2000

TOXALERT MODEL AIR 2000 TOXALERT MODEL AIR 2000 NOTE: Toxalert s Model GVU-CO 2 Sensor is the same as the Air2000R. Microprocessor-based, Infrared Environmental CO 2 Sensor OPERATOR S MANUAL TOXALERT TM INTERNATIONAL INC. P.O.

More information

with serial RS485/RS232 output

with serial RS485/RS232 output with serial RS485/RS232 output RS485 programmable sensors of temperature, humidity, atmospheric pressure and CO 2 with two-state inputs and relay outputs industry and interior design high quality, accurate

More information

User Manual. Per Port Monitoring Models

User Manual. Per Port Monitoring Models User Manual Per Port Monitoring Models Table of Contents 1. Introduction... 1 2. Package Contents... 2 3. Function... 3 4. Installation... 5 5. Web Interface... 6 1. Introduction The ServerLink Per Port

More information

CDD4 Duct Carbon Dioxide Transmitter

CDD4 Duct Carbon Dioxide Transmitter Drill or punch a 1-1/8 or 1-1/4 hole in the duct at the preferred location and insert the probe into the hole to mark the enclosure mounting holes. Remove the unit and drill the four mounting holes. Clean

More information

TRANSMITTERS. HygroFlex & HygroClip-EX. Applications. Highlights

TRANSMITTERS. HygroFlex & HygroClip-EX. Applications. Highlights HygroFlex & HygroClip-EX HygroFlex series may be used together with the intrinsically safe HygroClip-EX probes. The relative humidity and temperature can be displayed and output as analog signals. Calculated

More information

DXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions

DXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions DUAL DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL

More information

Output signal. 22DTM-16 BACnet DC V, DC V. Electrical data Power supply DC V, ±10%, 0.3 W

Output signal. 22DTM-16 BACnet DC V, DC V. Electrical data Power supply DC V, ±10%, 0.3 W Duct Sensor CO₂ / Humidity / Temperature For combined measurement of CO₂, relative humidity and temperature in the duct. Dual channel CO₂ technology. The measured values are output via BACnet. NEMA 4X

More information

Network Management Card. User Manual

Network Management Card. User Manual User Manual 1 Contents Contents 2 Chapter 1 Overview 3 1.1 NMC package contents 4 1.2 NMC CD Resources 4 1.3 Features 4 1.4 NMC Applications 5 Chapter 2 NMC parameters setting via serial COM port 6 2.1

More information

Page 1 MRK-D-0011, V2.0 Aeroqual SM50 User Guide

Page 1 MRK-D-0011, V2.0 Aeroqual SM50 User Guide Page 1 Table of Contents User Guide Revision History... 3 Description... 4 1. Operating Instructions... 4 1.1. Power... 4 1.2. Warm Up... 4 1.3. Standard Inputs and Outputs... 4 1.4. Using the Relay Output...

More information

EGW1-IA3-MB User s Manual

EGW1-IA3-MB User s Manual www.exemys.com Rev. 0 1 Products are in constant evolution to satisfy our customer needs. For that reason, the specifications and capabilities are subject to change without prior notice. Updated information

More information

USER S GUIDE. EE210 - Humidity and Temperature Transmitter for demanding Climate Control Applications GENERAL

USER S GUIDE. EE210 - Humidity and Temperature Transmitter for demanding Climate Control Applications GENERAL USER S GUIDE EE210 - Humidity and Temperature Transmitter for demanding Climate Control Applications GENERAL The EE210 transmitter, available for wall or duct mounting, is designed for the highly accurate

More information

Operation Manual SuperDry Data Logger (SDDL)

Operation Manual SuperDry Data Logger (SDDL) Operation Manual SuperDry Data Logger (SDDL) 1. Description This device has been equipped with custom-programmable logic module, mounted in it s own housing. The respective module serves to measure the

More information

RXTH DUAL ROOM SENSOR / SWITCH

RXTH DUAL ROOM SENSOR / SWITCH DUAL ROOM SENSOR / SWITCH FOR TEMPERATURE AND RELATIVE HUMIDITY Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE

More information

User manual NANO TEMPERATURE SENSOR

User manual NANO TEMPERATURE SENSOR User manual NANO TEMPERATURE SENSOR Soft >= 1.1 Dear Customer! INVEO s.c. ul. Rzemieślnicza 21 43-340 Kozy tel: +48 33 444 65 87 www.inveo.com.pl info@inveo.com.pl Thank you very much for choosing our

More information

Humidity goes Digital

Humidity goes Digital Industrial Humidity Temperature Transmitter Dew-point and other calculated values Wide range of digital interchangeable probes No need for field calibration PC compatible and RS485 networkable SWISS MADE

More information

Industrial Serial Device Server

Industrial Serial Device Server 1. Quick Start Guide This quick start guide describes how to install and use the Industrial Serial Device Server. Capable of operating at temperature extremes of -10 C to +60 C, this is the Serial Device

More information

smartden IP-WatchDog PING Restarter and Auto-Rebooter

smartden IP-WatchDog PING Restarter and Auto-Rebooter smartden IP-WatchDog PING Restarter and Auto-Rebooter User Manual Date: For firmware version: v1.21 / May 2017-1- Content smartden IP-WatchDog User Manual 1. Features... 3 2. Application examples... 4

More information

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 4 OPERATIONAL DIAGRAM 5 WIRING AND

More information

LAN Interface TCW120B

LAN Interface TCW120B LAN Interface TCW120B 1. Short description TCW120 is a multifunctional device for remote monitoring and management. It is an Ethernet based controller, which is designed to work in IP-based networks and

More information

IMIO100 IMIO105. DDC controllers. Summary

IMIO100 IMIO105. DDC controllers. Summary IMIO100 IMIO105 DDC controllers Summary DDC (Direct digital control) controller IMIO100 and IMIO105 are free programmable process stations with ARM Cortex M4 processor and OS FreeRTOS. They contain one

More information

IP Sensor IPS2222 User manual

IP Sensor IPS2222 User manual IP Sensor IPS2222 User manual Output LED indicators Power input 12VDC adapter 2 Relay outputs LED Indicators 1 wire 2 Dry 2 Analog Green : Power Yellow: Link temperature & humidity contact inputs inputs

More information

HPS-M -2 DIFFERENTIAL PRESSURE TRANSMITTER. Mounting and operating instructions

HPS-M -2 DIFFERENTIAL PRESSURE TRANSMITTER. Mounting and operating instructions DIFFERENTIAL PRESSURE Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 5 OPERATIONAL

More information

Operating instructions. Speed monitor D / / 2014

Operating instructions. Speed monitor D / / 2014 Operating instructions Speed monitor D200 80005257 / 00 05 / 2014 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5 2.2 Target group...5

More information

PTU300 Combined Pressure, Humidity and Temperature Transmitter

PTU300 Combined Pressure, Humidity and Temperature Transmitter PTU300 Combined Pressure, Humidity and Temperature Transmitter For Demanding Applications Features Barometric pressure, humidity, and temperature measurement in one transmitter RS-232C serial interface

More information

Installation of the PCMeasure Movement Sensor (30114)

Installation of the PCMeasure Movement Sensor (30114) 1. Hardware: Installation of the PCMeasure Movement Sensor (30114) Connect the sensor to a serial or parallel port of the PC using one of the PCMeasure adaptors, or directly to the PCMeasure Ethernet Box.

More information

CDD Carbon Dioxide Transmitter

CDD Carbon Dioxide Transmitter Introduction The OSA CO2 transmitter uses Infrared Technology to monitor CO2 levels within a range of 0 2000 ppm and outputs a linear 4-20 ma or 0-5/0-10 Vdc signal. The enclosure is designed to operate

More information

Operating and installation instructions Differential pressure monitor

Operating and installation instructions Differential pressure monitor Operating and installation instructions Differential pressure monitor RM-DPC Micro SensorLine Table of contents 1 Safety instructions...3 2 Equipment specification...3 3 Assembly...4 4 Step-by-step installation...4

More information

TEMPERATURE AND ENVIRONMENT MONITORING MONITORE * CONTROL * ALERT * RECORD * ANALYZE

TEMPERATURE AND ENVIRONMENT MONITORING MONITORE * CONTROL * ALERT * RECORD * ANALYZE TEMPERATURE AND ENVIRONMENT MONITORING MONITORE * CONTROL * ALERT * RECORD * ANALYZE A Solution for every need and every budget Offers built-in temperature and humidity sensors and allows external detectors

More information

Operating Instructions for Digital Thermometers. Model: DTM

Operating Instructions for Digital Thermometers. Model: DTM Operating Instructions for Digital Thermometers Model: 1. Contents 1. Contents... 2 2. Note... 3 3. Instrument Inspection... 3 4. Regulation Use... 3 5. Operating Principle... 4 6. Mechanical Connection...

More information

Ethernet controller TCW180B Users manual

Ethernet controller TCW180B Users manual Ethernet controller TCW180B Users manual 1. Short description TCW180B is 8-channel Ethernet relay board, which is designed to work in IP-based networks and managed by WEB interface or SNMP programs. This

More information

Page 1 MRK-D-0011, V1.1 Aeroqual SM50 User Guide

Page 1 MRK-D-0011, V1.1 Aeroqual SM50 User Guide Page 1 Table of Contents 1. Description... 3 2. Operating Instructions... 3 2.1. Power... 3 2.2. Warm Up... 3 2.3. Input and Output signals... 3 2.3.1. ZERO CAL... 4 2.3.2. RESET... 4 2.3.3. SPAN... 4

More information

Transmitters RHT-WM-485-LCD, RHT-DM-485-LCD and RHT-P LCD

Transmitters RHT-WM-485-LCD, RHT-DM-485-LCD and RHT-P LCD Transmitters RHT-WM-485-LCD, RHT-DM-485-LCD and RHT-P10-485-LCD TEMPERATURE AND HUMIDITY TRANSMITTER INSTRUCTIONS MANUAL V1.0x D 1 INTRODUCTION The RHT-WM-485-LCD, RHT-DM-485-LCD and RHT-P10-485-LCD transmitters

More information

EE310. High-End Humidity and Temperature Transmitter for Demanding Process Control. Typical applications. Features EE310 EE310

EE310. High-End Humidity and Temperature Transmitter for Demanding Process Control. Typical applications. Features EE310 EE310 is optimized for reliable measurement in demanding industrial applications. In addition to highly accurate measurement of relative humidity (RH) and temperature (T), the transmitter also calculates parameters

More information

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS PRODUCT DESCRIPTION ARTICLE CODES INTENDED AREA OF USE TECHNICAL DATA STANDARDS OPERATIONAL DIAGRAMS WIRING AND CONNECTIONS

More information

English. Operating manual. Transmitters / regulators HD45 HD46. Keep for future reference. Companies / Brands of GHM

English. Operating manual. Transmitters / regulators HD45 HD46.   Keep for future reference. Companies / Brands of GHM English Operating manual Transmitters / regulators HD45 HD46 Companies / Brands of GHM www.deltaohm.com Keep for future reference. 1. INTRODUCTION The instruments of the HD45 and HD46 series are transmitters,

More information

Modbus Manual Version Modbus Manual for Clean Room Panel CRP5

Modbus Manual Version Modbus Manual for Clean Room Panel CRP5 Page 1 of 42 Modbus Manual Version 1.03 Modbus Manual for Clean Room Panel CRP5 This manual is for persons who will use the Clean Room Panel Modbus protocol. It describes how messages are constructed and

More information

Innovative Electronics for a Changing World INDEX

Innovative Electronics for a Changing World INDEX Innovative Electronics for a Changing World INDEX 1. SYSTEM DESCRIPTION 2. BOARD CONNECTIONS terminals and indicators 3. CONNECTION DIAGRAM 4. START UP GUIDE and passwords 5. HOME PAGE 6. STATUS PAGE 7.

More information

VPort 06EC-2V Series Quick Installation Guide

VPort 06EC-2V Series Quick Installation Guide VPort 06EC-2V Series Quick Installation Guide Moxa IP Camera Edition 1.0, February 2017 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777

More information

3. Technical parameters

3. Technical parameters 1. Short description TCW181B-CM is 8-channel Ethernet relay board, which is designed to work in IP-based networks and managed by WEB interface or SNMP programs. The device can be used stand-alone or as

More information

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26 H20.0.34.6C-05 EASYBus-Sensor module for temperature from version V3.2 Operating Manual EBT 2R Content 1 INTENDED USE 2 2 GENERAL ADVICE 2 3 SAFETY INSTRUCTIONS 2 4 DISPOSAL NOTES 2 5 ASSIGNMENT 3 6 DIMENSION

More information

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies ADC7520 SERIES 1600W Battery Chargers and Power Supplies Wide output adjustment range 0 72VDC Analog control by external 0-5VDC voltage Temp.comp charging, sense as on option Power fail relay alarm Master-Slave

More information

MiG2 CONTROLLERS. 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities

MiG2 CONTROLLERS. 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities MiG2 CONTROLLERS 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities The MiG2 controllers incorporate: 2 Inputs (Configurable as Resistive, 0 10V, 0 20mA or 4 20mA) 2 or 4 Relay Outputs

More information

Modbus Manual Version Modbus Manual for PF4/5

Modbus Manual Version Modbus Manual for PF4/5 Modbus Manual Version 1.1 - Modbus Manual for PF4/5 Seite 2 1. Table of contents 1 Modbus protocol... 3 1.1. Structure of the Modbus protocol... 3 1.1.1 Modbus RTU / TCP... 3 1.2 Modbus Data Format...

More information

RXTP ROOM TEMPERATURE

RXTP ROOM TEMPERATURE ROOM TEMPERATURE CONTROLLER WITH PI CONTROL Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4

More information

In order to minimize the impact of rain, snow, ice and solar radiation on the measurement the EE33-M must be mounted inside a radiation shield.

In order to minimize the impact of rain, snow, ice and solar radiation on the measurement the EE33-M must be mounted inside a radiation shield. Humidity and Temperature Transmitter for High-end Meteorological Applications E33-M is optimized for reliable measurement under demanding weather conditions. Besides accurate measurement of relative humidity

More information

Instruction Manual Environmental Monitoring Unit with Optional POE. Watchdog 15 Series Firmware Version 1

Instruction Manual Environmental Monitoring Unit with Optional POE. Watchdog 15 Series Firmware Version 1 Instruction Manual Environmental Monitoring Unit with Optional POE Watchdog 15 Series Firmware Version 1 Geist 1821 Yolande Ave., Lincoln, NE 68521 800.432.3219 402.474.3400 F: 402.474.4369 www.geistglobal.com

More information

VAT series controller and transmitter. Manual

VAT series controller and transmitter. Manual VAT series controller and transmitter Manual 1. General describe.. 2. Notice for use.. 1 1 3. Panel & connection introduce.. 2 4. Operate introduce.. 5. Application introduce. 6. Communication. 7. Specification..

More information

Switched XPDU. 15A Model. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

Switched XPDU. 15A Model. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved. Switched XPDU 15A Model User & Installation Manual www.xpcc.com 2014. All rights reserved. (Rev 10/02/14) Table of Contents Introduction...4 PDU Package...4 Function...4 Interface...4 Installation...5

More information

RHT-WM-485-LCD Transmitter and RHT-DM-485-LCD Transmitter

RHT-WM-485-LCD Transmitter and RHT-DM-485-LCD Transmitter RHT-WM-485-LCD Transmitter and RHT-DM-485-LCD Transmitter TEMPERATURE AND HUMIDITY TRANSMITTER INSTRUCTIONS MANUAL V1.0x A 1 INTRODUCTION The RHT-WM-485-LCD and RHT-DM-485-LCD transmitters include high

More information

Poseidon MANUAL

Poseidon MANUAL Poseidon2 4002 MANUAL www.hw-group.com 2 Safety information The device complies with regulations and industrial standards in force in the Czech Republic and the European Union. The device has been tested

More information