CPX-E-System CPX-E-CEC-...-PN. Description. Function Commissioning Parameterisation [ ]

Size: px
Start display at page:

Download "CPX-E-System CPX-E-CEC-...-PN. Description. Function Commissioning Parameterisation [ ]"

Transcription

1 CPX-E-System CPX-E-CEC-...-PN Description Function Commissioning Parameterisation [ ]

2 CPX-E-CEC-...-PN Original instructions GDCC-CPX-E-CEC-PN-E N PI PROFIBUS PROFINET, Modbus, EtherCAT, Windows, CODESYS, SoftMotion are registered trademarks of the respective trademark owners in certain countries. Symbols used: Note Material damage or loss of function Recommendations, tips, references to other documentation 2 Festo GDCC-CPX-E-CEC-PN-EN

3 CPX-E-CEC-...-PN Table of Contents CPX-E-CEC-...-PN 1 About this document Further applicable documents Target group Product version Product labelling Specified standards Function General remarks Crossover detection (auto MDI/MDI-X) PROFINET IO Device description file Identification & maintenance (I&M) Internal address assignment Product overview Product design LED display components Control components Run/stop switch Connecting components Power supply Network connections Memory card slot [Card] USB interface [USB] Additional functions FTP server Web server Temperature sensor Real-time clock Diagnostics options LED indicators Diagnostics via EtherCAT Diagnostics via web server Parameterisation A Technical data B Terminology Index Festo GDCC-CPX-E-CEC-PN-EN English 3

4 1 About this document 1 About this document This document describes the function and parameterisation of the product stated in the title. Safe use of the product is described in a separate document 1.1 Further applicable documents. 1.1 Further applicable documents Document Description of system CPX-E (CPX-E-SYS) Instructions for use of system CPX-E (CPX-E-SYS) Instructions for use of controller CPX-E-CEC Documentation for the components in the system CPX-E and the connected peripherals Online help for CoDeSys V3 Tab. 1.1 Content Detailed description of the system CPX-E Instructions and important notes on mounting, electrical installation and maintenance tasks for a system CPX-E Instructions and important notes on the use and safe usage of the product Information on use of the components Detailed information on using the product with CoDeSys V3 and the Festo extensions. For all available product documentation Target group This document is intended for qualified specialised personnel. Experience with electrical control systems is required in order to understand this documentation. 1.3 Product version This document refers to the following product versions: Product Programming Version number CPX-E-CEC-C1-PN With CoDeSys V3 Revision 01 and above CPX-E-CEC- M1-PN With CoDeSys V3 and SoftMotion Revision 01 and above Tab. 1.2 The product version can be identified from the product label or with the help of appropriate software from Festo. Appropriate software for identifying the product version can be found in the Festo Support Portal Information on using the software can be found in the integrated Help function. There may be an updated version of this document for these or later product versions. Check whether a corresponding version of this document is available 4 Festo GDCC-CPX-E-CEC-PN-EN English

5 1 About this document 1.4 Product labelling The product label is located on the left-hand side of the module. Scanning the printed Data Matrix Code with an appropriate device opens the Festo Support Portal with the relevant documents for the product. Alternatively, the Product Key (11-character alphanumeric code on the product label) can be entered in the Support Portal search box. 1 Designation 2 Part number/serial number 3 Revision status 4 MAC ID 5 Data Matrix Code 6 Product Key 7 Certifications/warning symbols 8 Terminal allocation Fig Specified standards Version EN 60529: IEC : EN : IEC 61158: EN : IEC 61784: NE 21: IEC 61918: Tab. 1.3 Festo GDCC-CPX-E-CEC-PN-EN English 5

6 2 Function 2.1 General remarks The product is intended for operation as a controller in a system CPX-E and can be programmed with CoDeSys in accordance with IEC Communication with a higher-order controller takes place via PROFINET IO network with real-time protocol (RT). Modbus/TCP and standard Ethernet (TCP/IP) are also supported. Communication with a PC takes place via one of two network connections (Ethernet), which is connected to the controller by an integrated switch. The integrated switch supports both star and line topology and enables the division of the network into segments. With the use of additional switches and routers, the network can be divided into additional segments. This makes it possible to structure the network and achieve greater network expansion Crossover detection (auto MDI/MDI-X) The product supports crossover detection (auto MDI/MDI-X), so both patch cables and crossover cables can optionally be used. When using patch cables and crossover cables in the network, crossover detection must be activated in the higher-order controller. 2.2 PROFINET IO Device description file Configuration in the software for the higher-order PROFINET controller uses a device description file (GSDML file). This contains all the information required to parameterise the system CPX-E via control software (e.g. Siemens STEP 7). The device description file is available on the Festo Support Portal ( Identification & maintenance (I&M) The Identification & maintenance (I&M) function serves as an electronic product label for the controller as PROFINET IO device and offers uniform, manufacturer-independent access to device-specific information online. 6 Festo GDCC-CPX-E-CEC-PN-EN English

7 2.3 Internal address assignment In addition to the controller CPX-E-CEC, a maximum of 10 modules is permitted in one system CPX-E. The address space of a system CPX-E is limited. The controller provides the system CPX-E with a maximum address space of 64 bytes for inputs and 64 bytes for outputs. The internal addresses for the inputs and outputs of the system CPX-E are assigned automatically. Module CPX-E-16DI CPX-E-8DO CPX-E-4AI CPX-E-4AO CPX-E-4IOL CPX-E-1CI Fig. 2.1 Address assignment 2 byte inputs 1 byte outputs 8 byte inputs 8 byte outputs Max. 32 byte inputs and 32 byte outputs 12 byte inputs and 2 byte outputs 2.4 Product overview Product design 1 Network connection PROFINET IO port 1 [XF1] 2 Network connection PROFINET IO port 2 [XF2] 3 Slot cover for an operator unit (not included in scope of delivery) 4 LED display components 5 Ethernet network connection [ETH 1] 6 MicroSD slot [Card] 7 USB interface [USB] 8 EtherCAT master network connection [EC] 9 Ethernet network connection [ETH 2] aj Power supply terminal block U EL/SEN [XD] aa Terminal block lock aa aj 9 8 Fig. 2.2 Festo GDCC-CPX-E-CEC-PN-EN English 7

8 2.5 LED display components 1 Module-specific LED indicators Application [Run] (green) Connection/data traffic [LA ETH 1] [LA ETH 2] [LA EC] (green) 2 System-specific LED indicators Power supply U EL/SEN [PS] (green) Load power supply U OUT [PL] (green) System fault [SF] (red) Force mode [M] (yellow) 3 Network-specific LED indicators Network fault [NF] (red) Reserved [M/P] Connection [XF1] [XF2] (green) Fig Control components Run/stop switch The run/stop switch is situated under the cover Fig DIL switch for run/stop 2 Reserved 1 2 Fig. 2.4 Switch status Run (standard setting) Stop Run Stop Stop Run Tab. 2.1 Functions A project can be started using CoDeSys (run mode active). A CoDeSys boot application can be started. A project cannot be started using CoDeSys. A CoDeSys boot application cannot be started. A project that is running will be stopped. A projected that was stopped using the run/stop switch will be continued. If a program with real-time priority cannot be affected by the run/stop switch: 1. Set run/stop switch to Stop. (The boot application cannot be started.) 2. Restart the controller. 3. Establish connection to the CPX-E-CEC. 4. Delete boot application with Reset device source General help for CoDeSys V3. 8 Festo GDCC-CPX-E-CEC-PN-EN English

9 2.7 Connecting components Power supply Port [XD] 1) Signal V DC power supply U EL/SEN V DC power supply U EL/SEN 3 1) Ports XD.0 and XD.1 and ports XD.2 and XD.3, respectively, are connected to each other in the terminal block. Tab Network connections The network connections are designed as RJ45 sockets. Network connections CPX-E-CEC-...-PN function [XF1] PROFINET IO port 1 [XF2] PROFINET IO port 2 [ETH 1] Ethernet interfaces for connecting a programming unit, [ETH 2] PC or operator unit CDPX [EC] EtherCAT master Tab. 2.3 The network connections ETH1 and ETH2 are connected to the controller via a switch. Festo GDCC-CPX-E-CEC-PN-EN English 9

10 2.7.3 Memory card slot [Card] The slot is used to save data and results to a memory card CAMC-M-MS-G32. The data are saved in the directory /mnt/sdcard. The data can be accessed via Sysfile and CAA file CoDeSys libraries. Requirements Maximum memory size: 32 GB Formatting: FAT32 (one partition only) Note Use only memory cards that are sold by Festo as accessories for the product Festo does not provide any warranty for the use of other microsd memory cards. Note Do not use storage media for continuous data recording. The MicroSD slot is only intended for user-monitored operation. Memory cards cannot be used to execute CoDeSys boot projects USB interface [USB] The USB interface (A-coded socket, USB 2.0) is used to save data and results to external storage media. The data are saved in the directory /mnt/usb. The data can be accessed via Sysfile and CAA file CoDeSys libraries. Requirements Maximum memory size: 32 GB Formatting: FAT32 (one partition only) Note Impermissible operating states of the controller result from high current consumption at the USB interface. Use only storage media with current consumption 0.5 A. Note Do not use storage media for continuous data recording. The USB interface is only intended for user-monitored operation. USB storage devices cannot be used to execute CoDeSys boot projects. 10 Festo GDCC-CPX-E-CEC-PN-EN English

11 2.8 Additional functions FTP server The controller provides an FTP server. Data can only be accessed via the directory: /mnt/ftp Web server The integrated web server provides read access to the key parameters and diagnostic functions of the system CPX-E Diagnostics via web server Temperature sensor The controller has a sensor to measure the internal temperature. Reading the current temperature: via CoDeSys using the function block GetTemperature Festo_General_3 library via the web server of the controller Diagnostics via web server menu System --> Information Real-time clock The controller has a real-time clock, which can be set or read with the aid of CoDeSys function blocks: for run-time of CoDeSys projects CoDeSys library SysTimeRtc in online mode with the aid of the PLC shell CoDeSys V3 Festo GDCC-CPX-E-CEC-PN-EN English 11

12 2.9 Diagnostics options The module supports various diagnostics options, depending on the configuration and parameterisation of the system CPX-E. Diagnostics option Description Detailed information LED display components System-specific Module-specific Network-specific Festo Software EtherCAT System status and errors are displayed directly on the module via LED indicators. Information about CoDeSys programs, Ethernet and EtherCAT connections is displayed directly on the module via LED indicators. Status and errors in the PROFINET IO network are displayed directly on the module via LED indicators. Malfunctions or errors are displayed directly on a PC, meaning that diagnostics is also possible from a higher automation level. Diagnostics as part of the EtherCAT function via the network. Detailed module- and channel-related error detection by means of control software. Instructions for use of system CPX-E Description of system CPX-E Online help for software Web servers Diagnostics via web server Tab. 2.4 Further diagnostic options using CoDeSys can be found in the online help for the CPX-E-CEC. 12 Festo GDCC-CPX-E-CEC-PN-EN English

13 2.9.1 LED indicators Module-specific LED indicators This section describes the module-specific LED indicators. The network-specific LED indicators are described in the next section. The system-specific LED indicators are described in the documentation for the system CPX-E 1.1 Further applicable documents. Operation [RUN] LED (green) Meaning Remedy CoDeSys application is running lights up off Tab. 2.5 CoDeSys application is not available or has stopped Ethernet interfaces [ETH1] [ETH2] LED (green) Meaning Remedy Ethernet connection established status Link lights up flashes off Tab. 2.6 Ethernet connection established status Activity No connection or line not connected Check connection. EtherCAT interface [LAEC] LED (green) Meaning Remedy Ethernet connection established status Link lights up flashes off Tab. 2.7 Ethernet connection established status Activity No connection or line not connected Check connection. Festo GDCC-CPX-E-CEC-PN-EN English 13

14 Network-specific LED indicators This section describes the network-specific LED indicators for PROFINET IO. The module-specific LED indicators are described in the previous section. The system-specific LED indicators are described in the documentation for the system CPX-E 1.1 Further applicable documents. Network fault [NF] LED (red) Meaning Remedy Network connection not OK flashes Possible causes: Device name not correct Check device name. No connection to master Switch on master. Incorrect configuration Correct MAC addresses for fieldbus interface. PROFINET IO controller defective Repair controller. Network connection interrupted, short-circuited or disturbed Check network connection. Network connection to PROFINET IO controller off active, no network error Tab. 2.8 Connection status [XF1], [XF2] LED (green) Meaning Remedy PROFINET IO connection established lights up status Link flashes Locating module when both LEDs are flashing at the same intervals e.g. for error finding or during configuration. No connection to the respective port or line Check network connection. off not connected Tab Festo GDCC-CPX-E-CEC-PN-EN English

15 2.9.2 Diagnostics via EtherCAT The availability of diagnostic information via the EtherCAT network depends on the settings of the connected EtherCAT devices. Diagnostics via SDO access Diagnostic information can be requested from lower-order EtherCAT devices using SDO access. Diagnostics via diagnostics history The most recent diagnostic messages from lower-order EtherCAT devices can be displayed via the diagnostics object 0x10F3. An error message referenced with a code is displayed for every event (warning, error, information). A bus node CPX-FB37, for example, provides 20 diagnostic messages. The diagnostic messages are converted via the ESI file and can then be evaluated by the CoDeSys application. Structure of diagnostics object 0x10F3 Index (hex) Sub-index Description Data type Values Access 1) 0x10F3 0 Diagnostics history U8 RO 1 Maximum messages U8 20 RO 2 Newest message U8 RO 3 Newest acknowledged message U8 RW 4 New message available BOOL RO P 5 Flags U16 0x0000 RW 6 70 Sub-index BYTE [23] RO 1) RO = read only; RW = read/write; RO P = read only (PDO mappable) Tab The diagnostic messages for the lower-order EtherCAT device are stored in the diagnostics history. Sample diagnostic message: E F C5 9D The individual values of the diagnostic message are explained below. Values of diagnostic message Name 1) Value from example (hex) Explanation 1 Diag Code E1 CPX-E error number (2 = short circuit) 2) E1 = CPX-E error number E8 = Error code to DS401 2 Flags Number of parameters in the diagnostic message (2) and diagnostics type 2 (error message) 3 Text-ID Reference to ESI file with the clear text of the diagnostic message (<TextId>#x3702) 4 Time Stamp 1F C5 9D Local timestamp (time since controller start) 5 Flags Parameter Type of parameter 1 (UNSIGNED8) 6 Parameter 1 02 CPX module number 7 Flags Parameter Type of parameter 2 (UNSIGNED8) 8 Parameter 2 80 Channel 80 h (channel 128 d ) 1) To ETG ) See Description of system CPX-E Tab Text-IDs 3700 h... 37FF h correspond to CPX error numbers ( ). You can find more information in the Description of system CPX-E 1.1 Further applicable documents. Festo GDCC-CPX-E-CEC-PN-EN English 15

16 In addition to the CPX-specific text-ids, the ESI file also includes EtherCAT-specific text-ids. EtherCAT-specific text-ids from ESI file Text-ID (hex) Clear text (English) Clear text (English) 3800 Ident check failed for configured module Ident check failed for configured module 3801 Ident check skipped PLC has not written to Object 0xF030 Ident check skipped PLC has not written to Object 0xF F Calculate bus cycle time failed (local timer too slow) Calculate bus cycle time failed (local timer too slow) 0011 Sync Manager invalid address Sync Manager invalid address 0012 Sync Manager invalid size Sync Manager invalid size 0013 Sync Manager invalid settings Sync Manager invalid settings Tab The diagnostic message are written to a buffer (80 bytes). 2 operating modes are available for processing diagnostic messages: Overwrite mode: When the number of diagnostic messages reaches 20, old diagnostic messages are overwritten. Acknowledge mode: A diagnostic message must first be acknowledged before it can be overwritten with a new diagnostic message. When the number of unacknowledged diagnostic messages reaches 20, new diagnostic messages will not be saved and will be lost. Specifying operating mode for diagnostic message The operating mode for diagnostic messages can be read and written using diagnostics object 0x10F3 (sub-index 5, bit 4). Operating mode Value of bit 4 Overwrite mode 0 Acknowledge mode 1 Tab Mapping New message available message To simplify diagnostics evaluation, the controller offers the option of having the presence of a new diagnostic message evaluated by the process data. To do this, the object New message available can optionally be mapped to the process data. This is done via diagnostics object 0x10F3 (sub-index 4). Deactivating/activating emergency message The emergency message can be activated and deactivated using the diagnostics object 0x10F3 (sub-index 5, bit 0). Emergency message Value of bit 0 Deactivate 0 Activate 1 Tab Festo GDCC-CPX-E-CEC-PN-EN English

17 Emergency message If there is an error, the system CPX-E will transmit an emergency message which consists of the following: Structure of emergency message Byte 0 Byte 1 Byte 2 Byte 3 Byte 4 Byte 5 Byte 6 Byte 7 Error code 1) Error register Status bits CPX-E module number CPX-E error number Reserved Additional error Index 1001 Index 1002 (Manufacturer status register) 2) information 2) 1) In accordance with DS301/DS401 2) Device-typical error messages Tab Structure of emergency message Error code (byte 1, byte 0) Byte 1 Byte 0 Explanation No error General error Short circuit at the outputs Load dump (wire break) Input voltage too low Output voltage too low Hardware errors (all errors, 128) Tab Structure of emergency message Error register (byte 2) Bit Meaning Explanation 0 Generic error Bit is set for each error 1 Current Short circuit/overload in sensor supply (SCS) Short circuit/overload at outputs (SCO) 2 Voltage Undervoltage at outputs (U OUT ) Load voltage failure at output module or input module 3 4 Communication error Node guard, heart beat, fieldbus-specific only Manufacturer specific Wire break, other error Tab Structure of emergency message Status bits (byte 3) Bit Meaning Explanation 0 Error at valve Module type in which an error has occurred 1 Error at output 2 Error at input 3 Error on analogue or function module 4 Undervoltage Error type 5 Short circuit/overload 6 Wire break 7 Other error Tab Festo GDCC-CPX-E-CEC-PN-EN English 17

18 Structure of emergency message CPX-E module number (byte 4) Bit Meaning Explanation 0 7 CPX-E module number Number of the module with diagnostic message Tab Structure of emergency message CPX-E error number (byte 5) Bit Meaning Explanation 0 7 CPX-E error number CPX-E error number 1) 1) Description of system CPX-E Tab Structure of emergency message Additional error information (byte 7) Bit Meaning Explanation 0 7 Additional error information Tab For example: Node ID with Heart Beat error (which participant has caused the Time out?) Channel number of the first channel with error 18 Festo GDCC-CPX-E-CEC-PN-EN English

19 2.9.3 Diagnostics via web server Note Diagnostics via the web server can affect the real-time response of the CoDeSys application. 1. Connect PC to controller via the network. 2. Adjusts network settings. 3. Open the IP address of the controller in a web browser. IP address of controller: (factory setting) The IP address of the controller can be read from the controller using suitable software CoDeSys scan Festo devices or Festo Field Device Tool (FFT). Fig. 2.5 The following pages are available: CPX Terminal Module configuration of the system CPX-E Module addressing of the system CPX-E CI (communication interface) Execute commands on the CPX-E-CEC System Diagnostics information Information about the controller and current parameters Information about the controller manufacturer CoDeSys Information about the CoDeSys licence for the controller Festo GDCC-CPX-E-CEC-PN-EN English 19

20 3 Parameterisation 3 Parameterisation The behaviour of the system CPX-E can be set using the following parameters: System parameters Diagnostic memory parameters System bus parameters You can find a detailed description of the individual parameters in the Description of system CPX-E and in the descriptions of the corresponding modules 1.1 Further applicable documents. Parameter System parameter (CPX-E) Filter alarm U out /U val Monitoring of SCS Monitoring of SCO Monitoring of undervoltage U out Monitoring of undervoltage U val Monitoring of SCV Analogue process data format Diagnostic memory parameters (trace parameters) Entries saved retentively with Power On Run/stop filter 1 Run/stop filter 2 Error end filter Error number filter Module/channel filter Module number Channel number Error number System bus parameters (CPX-E) Synchronisation 2) Factory setting Tab. 3.1 Description/setting options You can find detailed information in the Description of system CPX-E 1.1 Further applicable documents. SCS = Short circuit/overload in sensor supply SCO = Short circuit/overload at the outputs SCV = Short circuit/overload at the valves Intel format/motorola format You can find detailed information in the Description of system CPX-E 1.1 Further applicable documents. Synchronisation with cycle time of CoDeSys application (MainTask) Online help 1.1 Further applicable documents. Detailed information on parameterisation can be found in the online help for CoDeSys V3. Observe the notes on installing CoDeSys V3 in the instructions 1.1 Further applicable documents. 20 Festo GDCC-CPX-E-CEC-PN-EN English

21 A Technical Data A Technical data General Feature Specification/value General technical data, system CPX-E Description of system CPX-E ( 1.1 Further applicable documents). Dimensions (length x width x height 1) ) [mm] x 75.9 x 82.5 Product weight 2) [g] 288 Mounting position Vertical/horizontal Ambient temperature [ C] ( 5 +50) 3) Storage temperature [ C] Air humidity [%] 0 95 Assigned address space (inputs/outputs) Without diagnostics [bit] / With status bits [bit] 8/ With I/O diagnostics interface [bit] 16/16 Module code/submodule code (CPX-E-specific) CPX-E-CEC-C1-PN 222/100 CPX-E-CEC-M1-PN 222/101 Module identification E-CEC Degree of protection to EN IP20 Protection against electric shock (protection against direct and indirect contact to IEC ) Through the usage of PELV circuits (protective extra-low voltage) Electromagnetic compatibility To EN /-4 and NE 21 CE marking (see declaration of conformity To EU EMC Directive To EC Machinery Directive The device is intended for use in an industrial environment. Measures for interference suppression may be required in residential areas. 1) Including cover ( Fig ), without linking 2) Including linking 3) With horizontal mounting position Tab. A.1 Power supply Feature Specification/value Power supply for electronics/sensors (U EL/SEN ) [V DC] 24 ± 25 % Intrinsic current consumption at nominal operating voltage [ma] 130 Reverse polarity protection 24 V U EL/SEN against 0 V U EL/SEN Yes Mains buffering time [ms] 20 Tab. A.2 Festo GDCC-CPX-E-CEC-PN-EN English 21

22 A Technical Data Network-specific Feature Specification/value Protocols PROFINET IO 1) EtherCAT Modbus/TCP Specification Standards/norms with reference to PROFINET: IEC IEC IEC Transmission rate [Mbps] 100 Crossover detection Auto-MDI/MDI-X Maximum cable length per segment [m] 100 Cable specification Cable type Ethernet twisted pair cable, screened Transmission Category Cat 5 or higher class Cable diameter [mm] 6 8 Wire cross section [mm²] ; 22 AWG 2) 1) Based on the Ethernet protocol IEEE ) Required for maximum connection length between network participants Tab. A.3 22 Festo GDCC-CPX-E-CEC-PN-EN English

23 B Terminology B Terminology Term/abbreviation Description Device description file Protocol-specific file for configuring the associated device with the aid of the software for the higher-order controller. The file contains all the information required to parameterise the system CPX-E. DIL switch Switches consisting of several switch elements with which settings can be made (dual in-line). ESI EtherCAT slave information GSDML file Device description file for PROFINET (Generic Station Description Markup Language) I/O Input and output I/O diagnostic interface Network-independent diagnostic interface at I/O level, which enables access to the internal data of the system CPX-E. I/O module Collective term for the modules that provide analogue or digital inputs/outputs. Modules CPX-E Collective term for the various modules which can be incorporated in a system CPX-E. PLC Programmable logic controller Status bits Internal status information (common diagnostic messages) of the system CPX-E, provided as input signals via the network. System CPX-E Complete system consisting of modules CPX-E. Tab. B.1 Terms and abbreviations Festo GDCC-CPX-E-CEC-PN-EN English 23

24 CPX-E-CEC-...-PN Index A Abbreviations, 23 Address assignment, 7 Analogue process value representation, 20 C Connection status, 14 Crossover detection (auto MDI/MDI-X), 6 D Device description file, 6 Diagnostic memory parameters, 20 Diagnostics history, 15 Diagnostics options, 12 LED indicators, 13, 14 via EtherCAT, 15 Diagnostics via EtherCAT, 15 Diagnostics history, 15 Emergency message, 17 SDO access, 15 E Emergency message, 17 F Filter alarm, 20 G GSDML file, 6 I Identification & maintenance, 6 L LED indicators, 13 Connection status, 14 Module-specific, 13 Network error, 14 Network-specific, 14 N Network error, 14 P Parameters, 20 Diagnostic memory, 20 System, 20 System bus, 20 S SCO monitoring, 20 SCS monitoring, 20 SCV monitoring, 20 SDO access, 15 Synchronisation, 20 System bus parameters, 20 Synchronisation, 20 System parameters Analogue process value representation, 20 Filter alarm, 20 SCO monitoring, 20 SCS monitoring, 20 SCV monitoring, 20 Undervoltage monitoring, 20 System parameters (CPX-E-specific), 20 T Terminology, 23 U Undervoltage monitoring, 20 W Web servers, Festo GDCC-CPX-E-CEC-PN-EN English

25

26 Copyright: Festo AG & Co. KG Ruiter Straße Esslingen Germany Phone: Fax: Reproduction, distribution or sale of this document or communication of its contents to others without express authorization is prohibited. Offenders will be liable for damages. All rights reserved in the event that a patent, utility model or design patent is registered. service_international@festo.com Internet:

CPX-E-CEC-... Controller. Description Function, Parameterisation [ ]

CPX-E-CEC-... Controller. Description Function, Parameterisation [ ] CPX-E-CEC-... Controller Description Function, Parameterisation 8071235 8071235 2018-09 [8071237] Translation of the original instructions CODESYS, EtherCAT, MODBUS are registered trademarks of the respective

More information

CPX-E-CEC-...-EP. Controller. Description Function, Parameterisation [ ]

CPX-E-CEC-...-EP. Controller. Description Function, Parameterisation [ ] CPX-E-CEC-...-EP Controller Description Function, Parameterisation 8071219 8071219 2018-09 [8071221] Translation of the original instructions CODESYS, EtherCAT, EtherNet/IP, MODBUS are registered trademarks

More information

System CPX-E. Bus module CPX-E-EC. Description. Protocol EtherCAT. Function Parameterisation [ ]

System CPX-E. Bus module CPX-E-EC. Description. Protocol EtherCAT. Function Parameterisation [ ] System CPX-E Bus module CPX-E-EC Description Protocol EtherCAT Function Parameterisation 8071155 2017-07 [8071157] Bus module CPX-E-EC Original instructions CPX-E-EC-E N EtherCAT, TwinCAT are registered

More information

System CPX-E. IO-Link master module CPX-E-4IOL- Description. Protocol IO-Link. Function Parameterisation [ ]

System CPX-E. IO-Link master module CPX-E-4IOL- Description. Protocol IO-Link. Function Parameterisation [ ] System CPX-E IO-Link master module CPX-E-4IOL- Description Protocol IO-Link Function Parameterisation 877 27-7 [879] IO-Link master module CPX-E-4IOL- Original instructions CPX-E-4IOL- -E N IO-Link is

More information

System CPX-E. Bus module CPX-E-PB. Description. Protocol PROFIBUS DP. Function Parameterisation [ ]

System CPX-E. Bus module CPX-E-PB. Description. Protocol PROFIBUS DP. Function Parameterisation [ ] System CPX-E Bus module CPX-E-PB Description Protocol PROFIBUS DP Function Parameterisation 8723 27-7 [8725] Bus module CPX-E-PB Original instructions CPX-E-PB-E N PI PROFIBUS PROFINET is a registered

More information

Automation system CPX-E

Automation system CPX-E Key features Key features The automation system CPX-E is a high-performance control and automation system focusing primarily on motion control functions for handling technology. It comprises individual

More information

Motion Terminal VTEM. Description. Motion App #02. Proportional directional control valve [ ]

Motion Terminal VTEM. Description. Motion App #02. Proportional directional control valve [ ] Motion Terminal VTEM Description Motion App #02 Proportional directional control valve 8071736 2017-12 [8071738] VTEM Translation of the original instructions VTEM-MA02-EN Firefox is a registered trademark

More information

Motion Terminal VTEM. Description. Motion App #04. Model-based proportional pressure regulation [ ]

Motion Terminal VTEM. Description. Motion App #04. Model-based proportional pressure regulation [ ] Motion Terminal VTEM Description Motion App #04 Model-based proportional pressure regulation 8086805 2018-05 [8086807] VTEM Translation of the original instructions VTEM-MA04-E N Firefox is a registered

More information

Compact performance. Brief description. CPV valve terminal with AS-Interface type CPV..-GE- ASI-8E8A-Z M8. English e [ ]

Compact performance. Brief description. CPV valve terminal with AS-Interface type CPV..-GE- ASI-8E8A-Z M8. English e [ ] Compact performance Brief description CPV valve terminal with AS-Interface type CPV..-GE- ASI-8E8A-Z M8 English 8080251 2017-11e [8080244] Translation of the original instructions Documentation on the

More information

Control blocks CPX-CEC- -V3

Control blocks CPX-CEC- -V3 Key features Application Controller The control blocks CPX-CEC- -V3 are modern control systems for CPX terminals that enable programming with CODESYS to IEC 61131-3. Programming in a global language CODESYS

More information

Terminal CPX. Bus node CPX-FB37. Description. Network protocol EtherCAT NH [ ]

Terminal CPX. Bus node CPX-FB37. Description. Network protocol EtherCAT NH [ ] Terminal CPX Bus node CPX-FB37 Description Network protocol EtherCAT 8029675 1406NH [8029664] CPX-FB37 Translation of the original instructions P.BE-CPX-FB37-EN EtherCAT,TwinCAT,CANopen,SPEEDCON,Torx,Windows

More information

Control block CPX-CM-HPP

Control block CPX-CM-HPP Key features New options for controlling drive technology The control block CPX-CM-HPP makes all of Festo s electric drive technology compatible with all industrial communication interfaces. CPX-CM-HPP

More information

Controller CECC-X-M1. Brief description. Controller CECC X M1 CECC X M1 MV CECC X M1 MV S a [ ]

Controller CECC-X-M1. Brief description. Controller CECC X M1 CECC X M1 MV CECC X M1 MV S a [ ] Controller CECC-X-M1 Brief description Controller CECC X M1 CECC X M1 MV CECC X M1 MV S1 8079349 2017-09a [8074647] PI PROFIBUS PROFINET, CANopen, CODESYS, EtherCAT, EtherNet/IP, IO-Link, and MODBUS are

More information

CPX-Terminal. Brief description. CPX analogue I/O modules CPX-4AE CPX-2AA. English e [ ]

CPX-Terminal. Brief description. CPX analogue I/O modules CPX-4AE CPX-2AA. English e [ ] CPX-Terminal Brief description CPX analogue I/O modules CPX-2AE CPX-4AE CPX-2AA English 8080173 2017-11e [8080175] Translation of the original instructions Documentation on the product For all available

More information

Application Note I-Port event/error list

Application Note I-Port event/error list Application Note I-Port event/error list A list of events and errors are transmitted via I-Port -ST-...LKP 100163 Title... I-Port event/error list Version... 1.10 Document no.... 100163 Original...en Author...

More information

Motor controllers CMMO-ST

Motor controllers CMMO-ST q/w Worldwide: Superb: Easy: Festo core product range Covers 80% of your automation tasks Always in stock Festo quality at an attractive price Reduces procurement and storing complexity qready for dispatch

More information

Operator units CDPX Key features

Operator units CDPX Key features Key features Properties Festo CDPX panels are high-performance processors combined with widescreen technology. They provide more functions at a higher resolution for the interfaces between man and machine.

More information

Controller CMXH-ST2 Key features

Controller CMXH-ST2 Key features Key features At a glance The controller controls two servo motors which drive an H-shaped rotating toothed belt. The toothed belt moves a slide, whose position is calculated by the controller from the

More information

SK CU4-PNT-C Part number:

SK CU4-PNT-C Part number: SK CU4-PNT-C Part number: 275 271 515 PROFINET IO Internal Bus Interface The bus interface may only be installed and commissioned by qualified electricians. An electrician is a person who, because of their

More information

Terminal CPX. Bus node CPX-FB14. Description. CANopen networkprotocol en 1411d [ ]

Terminal CPX. Bus node CPX-FB14. Description. CANopen networkprotocol en 1411d [ ] Terminal CPX Bus node CPX-FB14 Description CANopen networkprotocol 526410 en 1411d [8041138] Contents and general instructions Original... de Edition... en 1411d Designation... P.BE-FB14-EN Order no....

More information

Modular controllers CECX

Modular controllers CECX Key features At a glance Versatile The controller is functionally designed as a master and motion controller. It is a powerful control unit that can Economical simultaneously execute both comprehensive

More information

Terminal CPX. Electrical interface CPX CTEL 4 M12 5POL. Description. CTEL master module. I-Port a [ ]

Terminal CPX. Electrical interface CPX CTEL 4 M12 5POL. Description. CTEL master module. I-Port a [ ] Terminal CPX Electrical interface CPX CTEL 4 M12 5POL Description CTEL master module I-Port 574601 1411a [8041791] Electrical interface CPX CTEL 4 M12 5POL Translation of the original instructions P.BE-CPX-CTEL-EN

More information

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current Data sheet SIMATIC S7-1200F, CPU 1215 FC, COMPACT CPU, DC/DC/DC, 2 PROFINET PORT, ONBOARD I/O: 14 DI 24VDC; 10 DO 24V DC 0.5A; 2 AI 0-10V DC, 2 AO 0-20MA DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA

More information

SK TU4-CAO-C Part number:

SK TU4-CAO-C Part number: SK TU4-CAO-C Part number: 275 281 151 CANopen External Bus Interface The bus interface may only be installed and commissioned by qualified electricians. An electrician is a person who, because of their

More information

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current Data sheet SIMATIC S7-1200, CPU 1217C, COMPACT CPU, DC/DC/DC, 2 PROFINET PORT ONBOARD I/O: 10 DI 24V DC; 4 DI RS422/485; 6 DO 24V DC; 0,5A; 4 DO RS422/485; 2 AI 0-10V DC, 2 AQ 0-20MA; POWER SUPPLY: DC

More information

Profinet Module. User Manual. Contents

Profinet Module. User Manual. Contents User Manual Contents 1 Important User Information... 2 2 Installation... 3 3 Connection... 4 4 Device Configuration... 5 5 Operation... 7 6 Packet Structures... 8 7 Network Design... 16 8 Specifications...

More information

Terminal CPX. Electrical interface CPX-CTEL-2-M12-5POL-LK. Description Electronics NH [ ]

Terminal CPX. Electrical interface CPX-CTEL-2-M12-5POL-LK. Description Electronics NH [ ] Terminal CPX Electrical interface CPX-CTEL-2-M12-5POL-LK Description Electronics 8034116 1405NH [8034124] Electrical interface CPX-CTEL-2-M12-5POL-LK Translation of the original instructions P.BE-CPX-CTEL-LK-EN

More information

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current Data sheet SIMATIC S7-1200F, CPU 1214 FC, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 14 DI 24V DC; 10 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY 125 KB General information

More information

Controllers CECC Key features

Controllers CECC Key features Key features Application Controller State-of-the-art programming The controllers CECC are modern, compact and versatile controllers that enable programming with CODESYS according to IEC 61131-3. CODESYS

More information

General information. Display. Supply voltage

General information. Display. Supply voltage Data sheet SIMATIC S7-1200, CPU 1211C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 6 DI 24V DC; 4 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 50 KB General information Product

More information

Measuring modules CPX-CMIX

Measuring modules CPX-CMIX Key features At a glance Movement and measurement in one, as an integral component of the valve terminal CPX the modular peripheral system for decentralised automation tasks. The modular design means that

More information

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current Data sheet SIMATIC S7-1200, CPU 1215C, COMPACT CPU, DC/DC/DC, 2 PROFINET PORT, ONBOARD I/O: 14 DI 24V DC; 10 DO 24V DC 0.5A 2 AI 0-10V DC, 2 AO 0-20MA DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA

More information

SK CU4-CAO Part number:

SK CU4-CAO Part number: SK CU4-CAO Part number: 275 271 001 CANopen Internal Bus Interface The bus interface may only be installed and commissioned by qualified electricians. An electrician is a person who, because of their technical

More information

SK TU4-PBR Part number:

SK TU4-PBR Part number: SK TU4-PBR Part number: 275 281 100 PROFIBUS DP External Bus Interface The bus interface may only be installed and commissioned by qualified electricians. An electrician is a person who, because of their

More information

Motor controllers CMMS-ST, for stepper motors

Motor controllers CMMS-ST, for stepper motors Key features Performance characteristics Compactness Motion control Small dimensions Full integration of all components for controller and power section, including RS232 and CANopen interface Integrated

More information

Quick Start Guide PROFINET Switch 4/8-port. Version. 1en.

Quick Start Guide PROFINET Switch 4/8-port. Version. 1en. Quick Start Guide PROFINET Switch 4/8-port Version 1en www.helmholz.de Contents 1. Introduction 3 2. Preparing the PROFINET switch 4 3. Project planning for PROFINET switch 4 4. Setting the port properties

More information

General information. Display. Supply voltage

General information. Display. Supply voltage Data sheet SIMATIC S7-1200, CPU 1212C, COMPACT CPU, DC/DC/RLY, ONBOARD I/O: 8 DI 24V DC; 6 DO RELAY 2A; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 75 KB General information Product

More information

YJKP with Mitsubishi Q series PLC control via Modbus TCP

YJKP with Mitsubishi Q series PLC control via Modbus TCP Application Note YJKP with Mitsubishi Q series PLC control via Modbus TCP This type of document describes the settings of Modbus TCP communication between Mitsubishi Q series PLC and YJKP. YJKP 100162

More information

General information. Display. Supply voltage

General information. Display. Supply voltage Data sheet SIMATIC S7-1200, CPU 1211C, COMPACT CPU, DC/DC/RELAY, ONBOARD I/O: 6 DI 24V DC; 4 DO RELAY 2A; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 50 KB General information

More information

Service unit combinations MSE6, MSE series

Service unit combinations MSE6, MSE series Key features Overview Product description The MSE6-E2M is an intelligent pneumatic service unit for optimising the use of compressed air as an energy medium in industrial automation technology. Equipped

More information

CPX terminal. Bus node CPX-FB38. Electronics description. Network protocol EtherCAT. Description en 1301a [ ]

CPX terminal. Bus node CPX-FB38. Electronics description. Network protocol EtherCAT. Description en 1301a [ ] CPX terminal Bus node CPX-FB38 Electronics description Network protocol EtherCAT Description 562525 en 1301a [8024385] Contents and general safety instructions Original... de Edition... en 1301a Designation...

More information

Universal bus node CTEU-CO

Universal bus node CTEU-CO Universal bus node CTEU-CO Manual Functions and maintenance Bus node Type CTEU-CO Fieldbus Protocol CANopen Manual 573 768 en 1101NH [756 466] Installation Original... de Edition... en 1101NH Designation...

More information

CPX-FB36 in Ethernet/IP Mode

CPX-FB36 in Ethernet/IP Mode Application Note CPX-FB36 in Ethernet/IP Mode The application node contains a step by step explanation how to configure and handle a CPX-FB36 in Ethernet/IP mode with a Schneider M340 PLC and Unit Pro

More information

Terminal CPX. Bus node CPX-(M)-FB33/34/35/41. Description. Network protocol PROFINET IO en 1410d [ ]

Terminal CPX. Bus node CPX-(M)-FB33/34/35/41. Description. Network protocol PROFINET IO en 1410d [ ] Terminal CPX Bus node CPX-(M)-FB33/34/35/41 Description Network protocol PROFINET IO 548760 en 1410d [8041494] Contents and general safety instructions Original... de Version... en 1410d Designation...

More information

Application Note Commissioning VTEM connected to Beckoff PLC via CPX-FB38 bus node

Application Note Commissioning VTEM connected to Beckoff PLC via CPX-FB38 bus node Application Note Commissioning VTEM connected to Beckoff PLC via CPX-FB38 bus node Commissioning VTEM connected to Beckoff PLC via CPX-FB38 bus node VTEM 100186 Title... Commissioning VTEM connected to

More information

Controller CMXH. Description STO. Safe Torque Off (STO) [ ]

Controller CMXH. Description STO. Safe Torque Off (STO) [ ] Controller CMXH Description STO Safe Torque Off (STO) 8062612 1603 [8062614] CMXH Translation of the original instructions CMXH-STO-EN Identification of hazards and instructions on how to prevent them:

More information

General information. Configuration control. Display. Control elements. Supply voltage

General information. Configuration control. Display. Control elements. Supply voltage Data sheet SIMATIC S7-1500, CPU 1513-1 PN, CENTRAL PROCESSING UNIT WITH WORKING MEMORY 300 KB FOR PROGRAM AND 1.5 MB FOR DATA, 1. INTERFACE: PROFINET IRT WITH 2 PORT SWITCH, 40 NS BIT-PERFORMANCE, SIMATIC

More information

Fieldbus slave modules w/o I/Os

Fieldbus slave modules w/o I/Os tem SLIO Fieldbus slave modules w/o I/Os tem 500S tem 300S tem 100V Order number Figure Type IM 053CAN, CANopen slave IM 053DN, DeviceNet slave IM 053DP, PROFIBUS-DP slave IM 053EC, EtherCAT slave General

More information

Application Note. Modbus on CMMP-AS- -M3/M0. Connection and configuration of the motor controller CMMP-AS- -M3/M0 within a Modbus/TCP network.

Application Note. Modbus on CMMP-AS- -M3/M0. Connection and configuration of the motor controller CMMP-AS- -M3/M0 within a Modbus/TCP network. Application Note Modbus on CMMP-AS- -M3/M0 Connection and configuration of the motor controller CMMP-AS- -M3/M0 within a Modbus/TCP network. CMMP-AS M0, CMMP-AS M3 20005 Title... Modbus on CMMP-AS- -M3/M0

More information

AS-i Safety Relay Output Module with Diagnostic Slave

AS-i Safety Relay Output Module with Diagnostic Slave AS-i Safety Relay Output Module with Diagnostic Slave User Manual Revision date: 2013-01-30...supports the requirements for AS-i Safety up to SIL3 Subject to modifications without notice. Generally, this

More information

Product type designation

Product type designation Data sheet SIMATIC DP, CPU 1512SP-1 PN FOR ET 200SP, CENTRAL PROCESSING UNIT WITH WORKING MEMORY 200 KB FOR PROGRAM AND 1 MB FOR DATA, 1. INTERFACE, PROFINET IRT WITH 3 PORT SWITCH, 48 NS BIT-PERFORMANCE,

More information

General information. Configuration control. Display. Control elements. Supply voltage. Input current. Power. Power loss

General information. Configuration control. Display. Control elements. Supply voltage. Input current. Power. Power loss Data sheet SIMATIC S7-1500, CPU 1515-2 PN, CENTRAL PROCESSING UNIT WITH WORKING MEMORY 500 KB FOR PROGRAM AND 3 MB FOR DATA, 1. INTERFACE: PROFINET IRT WITH 2 PORT SWITCH, 2. INTERFACE: ETHERNET, 30 NS

More information

MODBUS TCP MODULE INSTRUCTIONS. for use with WSIQ2/WSE

MODBUS TCP MODULE INSTRUCTIONS. for use with WSIQ2/WSE INSTRUCTIONS MODBUS TCP MODULE for use with WSIQ2/WSE WorldWide Electric Corporation Phone: 1-800-808-2131 Fax: 1-800-711-1616 www.worldwideelectric.net Product Compatibility This communications module

More information

General information. Configuration control. Display. Control elements. Supply voltage. Input current. Power. Power loss

General information. Configuration control. Display. Control elements. Supply voltage. Input current. Power. Power loss Data sheet SIMATIC S7-1500, CPU 1511-1 PN, CENTRAL PROCESSING UNIT WITH WORKING MEMORY 150 KB FOR PROGRAM AND 1 MB FOR DATA, 1. INTERFACE: PROFINET IRT WITH 2 PORT SWITCH, 60 NS BIT-PERFORMANCE, SIMATIC

More information

SK CU4-EIP-C Part number:

SK CU4-EIP-C Part number: SK CU4-EIP-C Part number: 275 271 519 EtherNet/IP Internal Bus Interface The bus interface may only be installed and commissioned by qualified electricians. An electrician is a person who, because of their

More information

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current Data sheet SIMATIC S7-1200, CPU 1215C, COMPACT CPU, AC/DC/RELAY, 2 PROFINET PORT, ONBOARD I/O: 14 DI 24V DC; 10 DO RELAY 2A, 2 AI 0-10V DC, 2 AO 0-20MA DC, POWER SUPPLY: AC 85-264 V AC AT 47-63 HZ, PROGRAM/DATA

More information

AS-i Safety Relay Output Module with Diagnostic Slave

AS-i Safety Relay Output Module with Diagnostic Slave AS-i Safety Relay Output Module with Diagnostic Slave User Manual...supports the requirements for AS-i Safety up to SIL3 Revision date: 2016-03-9 Subject to modifications without notice. Generally, this

More information

crio PN Installation Instructions V0.2/ COMSOFT

crio PN Installation Instructions V0.2/ COMSOFT crio PN Installation Instructions V0.2/10.06.2015 COMSOFT crio PN-Installation- V0.2/10.06.2015 i:\icp\project\700391_crio_pn\anwenderdoku\installation\version_0.2\crio_pn_e.doc Revision History Version

More information

Terminal CPX. Bus node CPX-FB40. Description Electronics. Network protocol Ethernet POWERLINK NH [ ]

Terminal CPX. Bus node CPX-FB40. Description Electronics. Network protocol Ethernet POWERLINK NH [ ] Terminal CPX Bus node CPX-FB40 Description Electronics Network protocol Ethernet POWERLINK 8028651 1408NH [8028657] Bus node CPX-FB40 Translation of the original instructions P.BE-CPX-FB40-EN Ethernet

More information

SK CU4-ECT-C Part number:

SK CU4-ECT-C Part number: SK CU4-ECT-C Part number: 275 271 517 EtherCAT Internal Bus Interface The bus interface may only be installed and commissioned by qualified electricians. An electrician is a person who, because of their

More information

Supplementary device manual EtherCAT interface in the AS-i controllere A AC1391 AC1392

Supplementary device manual EtherCAT interface in the AS-i controllere A AC1391 AC1392 Supplementary device manual EtherCAT interface in the AS-i controllere A AC1391 AC139 firmware version RTS.x target from 15 for CoDeSys from version.3 English 739071_00_UK 01-0- Contents Revision: 16 December

More information

General information. Configuration control. Control elements. Supply voltage. Input current. Power. Power loss. Memory

General information. Configuration control. Control elements. Supply voltage. Input current. Power. Power loss. Memory Datasheet SIMATIC DP, CPU 1510SP-1 PN FOR ET 200SP, CENTRAL PROCESSING UNIT WITH WORKING MEMORY 100 KB FOR PROGRAM AND 750 KB FOR DATA, 1. INTERFACE, PROFINET IRT WITH 3 PORT SWITCH, 72 NS BIT-PERFORMANCE,

More information

General information. Configuration control. Display. Control elements. Supply voltage

General information. Configuration control. Display. Control elements. Supply voltage Data sheet SIMATIC S7-1500, CPU 1516-3 PN/DP, CENTRAL PROCESSING UNIT WITH WORKING MEMORY 1 MB FOR PROGRAM AND 5 MB FOR DATA, 1. INTERFACE: PROFINET IRT WITH 2 PORT SWITCH, 2. INTERFACE: ETHERNET, 3. INTERFACE:

More information

General information. Configuration control. Display. Control elements. Supply voltage. Input current. Power. Power loss

General information. Configuration control. Display. Control elements. Supply voltage. Input current. Power. Power loss Data sheet SIMATIC S7-1500, CPU 1516-3 PN/DP, CENTRAL PROCESSING UNIT WITH WORKING MEMORY 1 MB FOR PROGRAM AND 5 MB FOR DATA, 1. INTERFACE: PROFINET IRT WITH 2 PORT SWITCH, 2. INTERFACE: ETHERNET, 3. INTERFACE:

More information

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current Data sheet SIMATIC S7-1200, CPU 1215C, COMPACT CPU, DC/DC/DC, 2 PROFINET PORT, ONBOARD I/O: 14 DI 24V DC; 10 DO 24V DC 0.5A 2 AI 0-10V DC, 2 AO 0-20MA DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA

More information

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes Datasheet SIMATIC S7-1200, CPU 1215C, COMPACT CPU, DC/DC/DC, 2 PROFINET PORT, ONBOARD I/O: 14 DI 24V DC; 10 DO 24V DC 0.5A 2 AI 0-10V DC, 2 AO 0-20MA DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY:

More information

Operating Manual FPGA-based High-Speed Micro-PLC

Operating Manual FPGA-based High-Speed Micro-PLC ZX20T Operating Manual FPGA-based High-Speed Micro-PLC Zander GmbH & Co. KG Am Gut Wolf 15 52070 Aachen, Deutschland info@zander-aachen.de www.zander-aachen.de Part No.: E61-335-10 Edition: H03 This document

More information

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections Data sheet 3379_en_B 1 Description PHOENIX CONTACT 2015-07-14 2 Features Media converters provide

More information

General information. Display. Supply voltage. Input current. Encoder supply. Output current. Power loss. Memory

General information. Display. Supply voltage. Input current. Encoder supply. Output current. Power loss. Memory Data sheet SIPLUS S7-1200 CPU 1214C DC/DC/DC -40...+70 DEGREES C WITH CONFORMAL COATING BASED ON 6ES7214-1AG40-0XB0. COMPACT CPU, DC/DC/DC, ONBOARD I/O: 14 DI 24V DC 10 DO 24 V DC 2 AI 0-10V DC, POWER

More information

M-bus web server. Meters and Energy Cost Allocation WTV676-HB6035

M-bus web server. Meters and Energy Cost Allocation WTV676-HB6035 Meters and Energy Cost Allocation M-bus web server WTV676-HB6035 The web server reads out wireless or wired M-bus devices over Ethernet or the Internet using a browser. Power and connection for up to 20

More information

Operator units CDPX Key features

Operator units CDPX Key features Key features Properties Festo CDPX panels are high-performance processors combined with widescreen technology. They provide more functions at a higher resolution for the interfaces between man and machine.

More information

USER MANUAL. Longo programmable controller LPC-2.MC8 Main module. Version 10

USER MANUAL. Longo programmable controller LPC-2.MC8 Main module. Version 10 USER MANUAL Longo programmable controller LPC-2.MC8 Main module Version 10 SMARTEH d.o.o. / Poljubinj 114 / 5220 Tolmin / Slovenia / Tel.: +386(0) 388 44 00 / e-mail: info@smarteh.si / www.smarteh.si Written

More information

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current Data sheet SIMATIC S7-1200, CPU 1211C, COMPACT CPU, DC/DC/RELAY, ONBOARD I/O: 6 DI 24V DC; 4 DO RELAY 2A; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 50 KB General information

More information

SK TU4-IOE-M12-C Part Number

SK TU4-IOE-M12-C Part Number SK TU4-IOE-M2-C Part Number 275 28 256 IO Extension Only qualified electricians are allowed to install and commission the module described below. An electrician is a person who, because of their technical

More information

Servo press kit YJKP - Host interface

Servo press kit YJKP - Host interface Application Note Servo press kit YJKP - Host interface Host interface of the servo press kit YJKP: - Communication possibilities - Workflow - Object directory - Communication protocol - Communication Mobus

More information

General information. Display. Control elements. Supply voltage

General information. Display. Control elements. Supply voltage Data sheet SIMATIC S7-1500F, CPU 1511F-1 PN, CENTRAL PROCESSING UNIT WITH WORKING MEMORY 225 KB FOR PROGRAM AND 1 MB FOR DATA, 1. INTERFACE: PROFINET IRT WITH 2 PORT SWITCH, 60 NS BIT-PERFORMANCE, SIMATIC

More information

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current Data sheet SIMATIC S7-1200, CPU 1214C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 14 DI 24V DC; 10 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 100 KB General information Firmware

More information

User Manual Gateway component for EtherNet/IP

User Manual Gateway component for EtherNet/IP User Manual Gateway component for EtherNet/IP PR100066 1/7/2016 Table of Contents KUNBUS GmbH Table of Contents 1 General Information... 3 1.1 Disclaimer... 3 1.2 Notes Regarding this User Manual... 4

More information

General information. Display. Control elements. Supply voltage

General information. Display. Control elements. Supply voltage Data sheet SIMATIC S7-1500F, CPU 1516F-3 PN/DP, CENTRAL PROCESSING UNIT WITH WORKING MEMORY 1,5 MB FOR PROGRAM AND 5 MB FOR DATA, 1. INTERFACE: PROFINET IRT WITH 2 PORT SWITCH, 2. INTERFACE: ETHERNET,

More information

General information. Supply voltage. Input current. Encoder supply. Power loss. Memory

General information. Supply voltage. Input current. Encoder supply. Power loss. Memory Data sheet SIMATIC S7-1200, CPU 1215C, COMPACT CPU, AC/DC/RELAY, 2 PROFINET PORT, ONBOARD I/O: 14 DI 24V DC; 10 DO RELAY 2A, 2 AI 0-10V DC, 2 AO 0-20MA DC, POWER SUPPLY: AC 85-264 V AC AT 47-63 HZ, PROGRAM/DATA

More information

PROFINET MODULE. Communications module. User Guide. This manual is to be given to the end user en / a. Power. Error. Status.

PROFINET MODULE. Communications module. User Guide. This manual is to be given to the end user en / a. Power. Error. Status. 5201 en - 2014.09 / a Stop Ready Run Start Trip Reset Local LCL RMT Power This manual is to be given to the end user Error Status Link 1 TX/RX 1 Link 2 1 2 TX/RX 2 14702.A PROFINET MODULE Communications

More information

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current Data sheet SIMATIC S7-1200, CPU 1211C, COMPACT CPU, AC/DC/RELAY, ONBOARD I/O: 6 DI 24V DC; 4 DO RELAY 2A; 2 AI 0-10V DC, POWER SUPPLY: AC 85-264 V AC AT 47-63 HZ, PROGRAM/DATA MEMORY: 50 KB General information

More information

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current Data sheet SIMATIC S7-1200, CPU 1215C, COMPACT CPU, DC/DC/DC, 2 PROFINET PORT, ONBOARD I/O: 14 DI 24V DC; 10 DO 24V DC 0.5A 2 AI 0-10V DC, 2 AO 0-20MA DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA

More information

CODESYS 3 Programmable Gateway for the BL67 I/O System Multiprotocol Ethernet gateway for PROFINET, EtherNet/IP and Modbus TCP BL67-PG-EN-V3

CODESYS 3 Programmable Gateway for the BL67 I/O System Multiprotocol Ethernet gateway for PROFINET, EtherNet/IP and Modbus TCP BL67-PG-EN-V3 CODESYS V3 programmable acc.to IEC 61131-3 Ethernet and USB programming interface Protection class IP67 Integrated power supply LEDs for display of PLC status, supply voltage, group and bus errors Programmable

More information

Position transmitter SDAT-MHS e [ ]

Position transmitter SDAT-MHS e [ ] Position transmitter SDAT-MHS en Manual 8068247 1612e [8068249] Translation of the original instructions SDAT-MHS This documentation refers to the following version: From Revision R04. Identification of

More information

MGate 5102-PBM-PN Series

MGate 5102-PBM-PN Series MGate 5102-PBM-PN Series 1-port PROFIBUS-to-PROFINET gateways Features and Benefits Protocol conversion between PROFIBUS and PROFINET Supports PROFINET IO device Supports PROFIBUS DP V1 master Automatic

More information

AS-interface modules CESA

AS-interface modules CESA Key features Basic principles and features of the bus system Introduction The AS-interface system permits the transfer of power and data using a single cable. The advanced technology used to connect stations

More information

Ethernet/IP Module. User Manual. Contents

Ethernet/IP Module. User Manual. Contents User Manual Contents 1 Important User Information... 2 2 Installation... 3 3 Connection... 4 4 Device Configuration... 5 5 Operation... 8 6 Packet Structures... 9 7 Network Design... 18 8 Specifications...

More information

Quick Start Guide PN/CAN-Gateway. Version. 1 en. from FW

Quick Start Guide PN/CAN-Gateway. Version. 1 en. from FW Quick Start Guide PN/CAN-Gateway Version 1 en from FW 1.00 www.helmholz.com Content 1. Introduction 3 2. Preparation of the PN/CAN-Gateway 3 3. Plan PN/CAN-Gateway 4 4. Configure PN/CAN-Gateway 5 5. Add

More information

Terminal CPX. Bus node CPX FB36. Description. Network protocol EtherNet/IP Modbus TCP. Industrial Ethernet 2-Port en 1611a [ ]

Terminal CPX. Bus node CPX FB36. Description. Network protocol EtherNet/IP Modbus TCP. Industrial Ethernet 2-Port en 1611a [ ] Terminal CPX Bus node CPX FB36 Description Network protocol EtherNet/IP Modbus TCP Industrial Ethernet 2-Port 8024075 en 1611a [8067476] Contents and general instructions Original... de Version... en

More information

Handbook ASI-PRG-ADR. AS-Interface Addressing Device. Festo AG & Co de 0004a

Handbook ASI-PRG-ADR. AS-Interface Addressing Device. Festo AG & Co de 0004a Handbook ASI-PRG-ADR AS-Interface Addressing Device Festo AG & Co. 360 039 de 0004a AS-Interface is a registered Trademark of the AS-International Association We recognise a duty to make a contribution

More information

SK CU4-PBR-C Part number:

SK CU4-PBR-C Part number: SK CU4-PBR-C Part number: 275 271 500 PROFIBUS DP Internal Bus Interface The bus interface may only be installed and commissioned by qualified electricians. An electrician is a person who, because of their

More information

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current Data sheet SIMATIC S7-1200, CPU 1211C, COMPACT CPU, DC/DC/RELAY, ONBOARD I/O: 6 DI 24V DC; 4 DO RELAY 2A; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 50 KB General information

More information

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory Datasheet SIMATIC S7-1200, CPU 1214C, COMPACT CPU, AC/DC/RLY, ONBOARD I/O: 14 DI 24V DC; 10 DO RELAY 2A; 2 AI 0-10V DC, POWER SUPPLY: AC 85-264 V AC AT 47-63 HZ, PROGRAM/DATA MEMORY: 75 KB Display with

More information

Motor controllers CMMP-AS, for servo motors

Motor controllers CMMP-AS, for servo motors Key features Comparison of motor controllers Motor controller CMMP-AS CMMS-ST for motor type Servo motor Stepper motor Positioning records 255 63 Measuring system Analogue/incremental/absolute Incremental

More information

General information. Display. Control elements. Supply voltage

General information. Display. Control elements. Supply voltage Data sheet SIMATIC S7-1500F, CPU 1513F-1 PN, CENTRAL PROCESSING UNIT WITH WORKING MEMORY 450 KB FOR PROGRAM AND 1.5 MB FOR DATA, 1. INTERFACE: PROFINET IRT WITH 2 PORT SWITCH, 40 NS BIT-PERFORMANCE, SIMATIC

More information

Quick Start Guide NETL ink Ethernet Gateways

Quick Start Guide NETL ink Ethernet Gateways Version en as of FW. Quick Start Guide NETL ink Ethernet Gateways www.helmholz.com Content. Introduction. Checking the Network Situation. Preparing the NETL ink. IP Address Settings on the PG/PC Network

More information

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory Datasheet SIMATIC S7-1200, CPU 1214C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 14 DI 24V DC; 10 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 75 KB Display with display Supply

More information

Type 70906X. Thyristor Power Controller TYA 201, 202 und 203. Interface description EtherCAT for Type , and XT92Z001K000

Type 70906X. Thyristor Power Controller TYA 201, 202 und 203. Interface description EtherCAT for Type , and XT92Z001K000 Type 70906X Thyristor Power Controller TYA 201, 202 und 203 Type 709061/8-01-020 Type 709062/8-01-100 Type 709063/8-01-20 Interface description EtherCAT for Type 709061, 709062 and 709063 7090610XT92Z001K000

More information

CODESYS 3 Programmable Gateway for the BL20 I/O System Multiprotocol Ethernet Gateway for PROFINET, EtherNet/IP and Modbus TCP BL20-PG-EN-V3

CODESYS 3 Programmable Gateway for the BL20 I/O System Multiprotocol Ethernet Gateway for PROFINET, EtherNet/IP and Modbus TCP BL20-PG-EN-V3 Programmable multiprotocol Ethernet gateway for PROFINET, EtherNet/IP and Modbus TCP OPC-Server CODESYS V3 programmable acc.to IEC 61131-3 Ethernet and USB programming interface Protection type IP20 Integrated

More information