R&S VSE Vector Signal Explorer Release Notes Firmware Version V1.40

Size: px
Start display at page:

Download "R&S VSE Vector Signal Explorer Release Notes Firmware Version V1.40"

Transcription

1 R&S VSE Vector Signal Explorer Release Notes Firmware Version V1.40 These Release Notes are for following models of the R&S VSE Vector Signal Explorer: R&S VSE, order no Rohde & Schwarz GmbH & Co. KG Muehldorfstr. 15, Munich, Germany Phone: Fax: Internet: Subject to change. R&S is a registered trademark of Rohde & Schwarz GmbH & Co. KG. Trade names are trademarks of the owners. The following abbreviations are used throughout this document: R&S VSE is abbreviated as R&S VSE. Release Notes Test and Measurement PAD-T-M: /02.00/CI/1/EN/

2 New Functions Table of Contents New Functions Modified Functions Improvement Known Issues Modifications to the Documentation Software Installation Installing the Software on your PC Installing Software Options Software options included in base software Other Firmware Options within the VSESetup.exe File Enabling Options by Entering Option Key Codes Customer Support Release Notes

3 1 1.1 New Functions The following table lists the new functions and indicates the version in which the new function was introduced: New Functions in Software V1.40: Version Function V1.40 Support for FSW-B2001 V1.40 Support for VSE-K96 OFDM VSA V1.40 Analog Baseband Support with RTO1000 and RTO2000 series V1.40 Support of external and IF-Power Trigger for FSW-B1200 V1.40 Update of R&S Visa to Version V1.40 Support for 20GHz sampling rate when using RTO in Waveform mode V1.40 VSE-K70: Start of the current result range within the capture buffer can now be queried with sample precision by [SENSe:]DDEMod:SEARch:MBURst:STARt:SAMPles? VSE-K70: All eye diagrams support two horizontal and two vertical display lines, which allow a manual measurement of the eye size (Limits -> Vertical/Horizontal Line ). VSE-K70: Predefined display configurations are offered for e.g. PSK/QAM signals and FSK signals (File -> Preset-> Predefined Display ) V1.40 K6: Increased pulse analysis limit to 200,000 pulses V1.40 K100/104: The parameter Channel Estimation can now be set to Off, which deactivates the equalizing filter. New Functions in Software V1.30: Version Function V1.30 Support for VSE-K60 Transient Analysis V1.30 Support for RTO2064 V1.30 IQ Analyzer: Added SEM Measurement V1.30 IQ Analyzer: Support for Low Noise Mode and 200 MHz Filter of FSW when using corresponding FSW with Firmware 2.50 or higher and the corresponding hardware options. V1.30 Added Drag and Drop for I/Q Files. Drag any supported file onto the Channel Information or the channel in the Measurement Group setup dialog in order to load the file for analysis V 1.30 New file dialogs with folder tree. V1.30 Remote trace query and IQ trace query now support 64 bit (more precise) or 16 bit (faster). Select the format with the commands FORMat REAL,64 or FORMat REAL,16 prio to querying the trace data. V1.30 Supports Limit Line Import and Export using CSV (comma separated) files. V1.30 OBW measurement supports the readings Centroid and Offset Frequency V1.30 Support of open source acknowledgement information pages. V1.30 K6: Added support for the TRACe:IQ command V1.30 K6: Supports Pulse I and Q result range trace display K6: Supports Pulse I and Q amplitude values in the Pulse Results and Pulse Statistics table displays V1.30 K6: Supports measurement results for pulse envelope model. V1.30 K6: Supports configuration to highlight data points in the trend display. Release Notes

4 Version Function V1.30 K70: Support of Shaped Offset QPSK modulation added. This includes the new modulation Shaped Offset QPSK, the new transmit filter Shaped Offset QPSK TG and the new digital standard SOQPSK-TG K70: Support of 16FSK and 32FSKmodulation K70: A symbol rate error can now also be estimated and compensated for MSK, QPSK and SOQPSK modulations V1.30 K70: New SCPI command to query length of a found burst: CALCulate:DDEM:BURSt:LENGth? V1.30 K70: Supports /2-BPSK and /2-DBPSK modulation V1.30 K70: Supports six additional predefined standards for Bluetooth (2-DH1/DH3/DH5 and 3-DH1/DH3/DH5) K70: Supports two additional predefined standards for DOCSIS 3.0 Downlink (J83B) K70: Bit errors are highlighted in the symbol table. Their position can be queried with TRACe:DATA? MSTR. K70: The position of incorrect pattern symbols can now be queried with TRACe:DATA? PSTR. K70: User Patterns can now be imported from the symbol table. K70: Lower limit for Alpha/BT of the transmit and measurement filter is now 0.03 for Gauss, GMSK, RC and RRC filters V1.30 K70: Supports an oversampling of 64 and 128 V1.30 K70: Supports dbmv and dbµv as units V1.30 K91: Support of new FSW-B320 option (order no ) K91: New SCPI command to change the position of the splitter between result windows. (LAYout:SPLitter) V1.30 K91/N/AC: Spectrum Flatness Result Configuration supports the trace units dbm and db. V1.30 K91N/AC: Tracking results from Preamble+Payload or Payload can be used for Preamble Channel Estimation V1.30 K100 and K104: New results Mean, Peak, Crest, 10%, 1%, 0.1% and 0.01% for CCDF-EVM V1.30 K100: Supports following new result displays: UE-specific RS Weights Magnitude and UE-specific RS Weights Phase Cell ID RS Weights Magnitude and Cell IR RS Weights Phase CSI RS Weights Magnitude and CSI RS Weights Phase Beamforming Allocation Summary V1.30 K100 and K104 Downlink: New results Mean, Peak, Crest, 10%, 1%, 0.1% and 0.01% for CCDF-EVM K100/102/104 Downlink: Supports measuring of up to 2 component carriers in EVM measurements with one sweep. This feature requires K102. K100/102/104 Downlink: Added new Softkey Auto LTE Config detecting automatically the Signal bandwidth and MIMO mode in EVM measurement. This functionality only works for signals with a valid PBCH and requires K102. K100/102/104 Downlink: Supports new LTE-Advanced test models with 256QAM allocations. This feature requires K102. K100/102/104 Downlink: Supports 1024QAM demodulation in Detection Mode Predefined. This feature requires the K102 option. K100/102/104 Downlink: Readout of EVM, Power and Allocation ID by SCPI in the diagrams EVM vs Symbol x Carrier, Power vs Symbol x Carrier and Allocation ID vs Symbol x Carrier K100/102/104 Downlink: Implementation of SCPI query command MMEM:LOAD:TMOD:DL? V1.30 K100/102/104 Uplink: Supports Subwindow Coupling. This functionality requires FSW-K102. K100/102/104 Uplink: Supports Single Subframe Mode which analyzes only one subframe for performing high speed measurements K100/102/104 Uplink: Supports PUSCH and PUCCH identities different from the cell Identity K100/102/104 Uplink: Supports n_pucch Auto for PUCCH K100/104 Uplink: Support of 256QAM demodulation. This feature requires the K102 option Release Notes

5 Version Function K100/102/104: Supports measuring of up to 2 component carriers in EVM measurements with one sweep. This feature requires V1.30 K106 Uplink: Support of NPRACH analysis K106 Downlink and Uplink: New measurement Spectrum Emission Mask 1.2 Modified Functions The following table lists the modified functions and indicates the version in which the modification was carried out: Modified functions of Software V1.40: Version Function 1.40 VSE-K70: FSK Ref Deviation can now be set to 60 * Symbol Rate (15 * Symbol Rate before) VSE-K70: The maximum number of Display Points/Sym for all result windows is now limited to 32 (exceptions: Result Summary and Capture Buffer Displays) Modified functions of Software V1.30: Version Function V1.30 Spectrum Emission Mask: For the file 802_11ad_2160MHz_60GHz_band.XML in subfolder WLAN\802_11ad\ the VBW is changed to 300 khz according to the change in the WLAN802.11ad standard. V1.30 Scrolling in result tables is now possible by swiping inside the table in addition to using the scroll bars. V1.30 The query answer string of *OPT? is now always terminated with a comma to simply string comparison. V1.30 Remote Control: The length of the Error Queue has been changed from 5 to 16 entries. Now, after 16 errors, the error queue is full and the last error will be "Queue Overflow". It is possible to clear the error queue, e.g. with *CLS, or to read the errors with SYST:ERR? and empty the queue entry by entry. V1.30 K7: Maximum FM scaling setting increased from 100 to 250 MHz/div V1.30 K70: The error message Pattern not found is replaced by Pattern symbols incorrect or Pattern waveform not found depending on the actual issue. K70: If the symbol table format is binary, the leading zeros are no longer suppressed when the values are queried with TRAC:DATA? STR. K70: Changed behavior upon manual refresh, if the statistic count exceeds the number of possible evaluations within the current capture buffer. V1.30 K70: Switching the symbol table between hexadecimal, decimal, octal and binary, can now also be done via Remote Control (CALC:FORM). When reading the symbol table via remote control this setting is taken into account if the command TRAC:DATA? STR is used. Release Notes

6 1.3 Improvement The following tables list the improvements and indicate since which version the issue could be observed: Improvements of Software V1.40: since Function 1.10 VSE-K70: File input can now be selected by INP:SEL FIQ Improvements of Software V1.31: since Function CMA-K305 and CMA-K310 were not recognized correctly. This issue is solved. Improvements of Software V1.30: since Function I/Q Analyzer: In spectrum displays the trace copy function did not work. This issue is solved. Creating and then loading a Save Set while not in Multiview Mode would lead to missing windows. This issue is solved The marker entry field was not continuously updated while dragging a marker symbol via the touchscreen. This issue is solved. The remote command for setting the trace ascii export format :FORMat:DEXPort:FORMat CSV DAT is now working. K6: Fixed an issue where exporting the Result Range could export more than the selected Result Range length. K6: Exporting the Pulse Results table would lockup the firmware if a K6S license was not present. This issue is solved. K6: Fixed an issue with the ASCII trace export of the Result Range Spectrum display. K6: The first time a file is loaded after creating a Pulse channel, the measurement does not run until the user toggles between Instrument and File. This issue is resolved. K70: Improved accuracy of recursive calculation of standard deviation for result summary. For small sweep counts, this results in slightly higher values. K70: The graph of the equalizer Impulse Response Phase measurement was corrected. All other measurements with active equalizer are not affected. K70: Improved burst search algorithm robustness K70: Improved average measurement signal processing algorithms for I/Q bandwidths <= 80 MHz. K70: Improved demodulation stability for non-msk modulations in combination with a GMSK filter with a roll-off of <=0.6 and a Gauss filter with a roll-off of <= 0.4. (This change might slightly reduce the measurement speed for the abovementioned scenarios.) K70: Measurement filter for Shaped Offset QPSK modulation is now applied correctly. K70: Known Data files for 512QAM, 1024QAM, 2048QAM and 4096QAM modulations could not be loaded. This issue is solved. K70: TRAC:DATA? is now supported if the result type is Real/Imag. K70: If a known data file is used, the reference signal in the I/Q constellation diagram now displays the reference signal based on the settings made for fine synchronization. K70: User-defined standards now support user-defined modulations. K91: the remote command SENSe:DEMod:FORMat:AUTO 1 did not work correctly. K91: The marker readout now matches the set amplitude unit. Release Notes

7 since Function K101/K104: Added missing remote command[:sense{1 2}][:LTE] [:CC{1...5}]:PREamble:SELect <numeric_values> ALL which selects the preamble to be analyzed. Release Notes

8 1.4 Known Issues The following table lists the known issues and indicates since which version the issue could be observed: since V 1.05 V 1.10 Function IQ Vector display can slow down VSE when choosing a long record length K6: The following commands are not available: [SENSe:]FREQuency:CENTer:STEP V1.10 Saving and Recalling Matlab Files (*.mat) only supports ASCII compatible File names unless activated in windows. In order to allow Unicode characters in file names, make sure to enable support for 8.3 file names on the drive(s) the file is being read from or exported to. For more information please refer to this MSDN: V1.40 K96: The CP indicator lines in the Impulse Response don't get updated if "FFT Shift relative to Cyclic Prefix Length" is different from 0.5. The following table lists known issues with supported instruments and additional Software: Function VSE-K100/104: Using the current FSV or FSW Firmware the Frame Start Offset calculation has an accuracy of less than +/- 100ns with the current FSV and FSW Firmware K72: Using the current FSV or FSW Firmware the Trigger to Frame calculation has an accuracy of less than +/- 100ns Instrument / Software FSV FSW FSV FSW FW/SW Version all all The Auto Level doesn t finish when connected with an RTO. The Reference Level Setting doesn t work reliable The VSE Software will stop working at random when visa packages from different vendors are installed in parallel on the PC. Removing the ambiguity solves this issue. Using the R&S Visa (V ) can cause the R&S VSE to stop measuring IQ data. The issue was observed using the Waveform Mode of the RTO (default in VSE-K6) or with high traffic on the LAN connection. RTO FW 2.6x.x FW 2.7x.x, FW 3.4.x.x Any VISA R&S VISA Modifications to the Documentation Release Notes

9 Software Installation 2 Software Installation The software installation file for the R&S VSE is one file including the main version number e.g. VSESetup_V1.30.exe. It will be referred to as VSESetup.exe later in the text. The file can be found on the Rohde & Schwarz web page. The R&S VSE can only be installed on the 64 Bit Version of Windows 7 or Windows Installing the Software on your PC Performing the installation on your PC: The R&S VSE needs some additional software components to run properly. The following components are needed: Microsoft.NET Framework Version 4.0 VISA (Virtual Instrument Software Architecture) Install Microsoft.NET Framework The R&S VSE installer will try to install the.net 4.0 from the internet. Install VISA It is necessary to install VISA (Virtual Instrument Software Architecture) to access instruments connected to the PC via IEEE or LAN bus. Please use the R&S VISA. Please visit to get the latest. Installing VSE Please save the VSE Installer on your hard disc in order to install the Software Release Notes

10 Software Installation 2.2 Installing Software Options Software options included in base software The K7 application software package is included in the base software. Therefore, it does not have a separate item in the installer to be selected Other Firmware Options within the VSESetup.exe File The R&S VSE-K70 and other application software packages have their own installation item and are therefore added to the selection list during the software update. Ensure that the checkboxes are checked if installation is requested. The R&S VSE V1.40 is compatible to the following options: VSE-K6 VSE-K10 VSE-K60 VSE-K70 VSE-K72 VSE-K91 V1.40 V1.40 V1.40 V1.40 V1.40 V1.40 VSE-K96 VSE-K100 VSE-K102 VSE-K104 VSE-K106 V1.40 V1.40 V1.40 V1.40 V Enabling Options by Entering Option Key Codes This section can be skipped if the option key was entered once. To activate application software packages, you must enter a license key for validation. If a XML-file with an option key was sent to you see the install description below. The license key is in the device certificate or delivered as a part of the software package. The process is performed in the following steps: 1. Go to the "Help" menu 2. Press the "License" menu item. 3. Press the "Install Option" Button A dialog box is displayed. 4. Enter the option key number. 5. Press "ENTER". After a successful validation the message "Option Key valid" is displayed. If the validation failed, the option software is not installed. 6. Restart the software. Release Notes

11 Software Installation Installation of options via XML-file 1. Go to the "Help" menu. 2. Press the "License" menu item. 3. Press the button "Install Option by XML" button. A file browser is displayed. 4. Select the path to the XML file (e.g. network drive or USB stick). 5. Press "Select". After a successful validation the message "Option Key valid" is displayed. If the validation failed, the option software is not installed. 6. Reboot the device. Release Notes

12 Customer Support 3 Customer Support Technical support where and when you need it For quick, expert help with any Rohde & Schwarz equipment, contact one of our Customer Support Centers. A team of highly qualified engineers provides telephone support and will work with you to find a solution to your query on any aspect of the operation, programming or applications of Rohde & Schwarz equipment. Up-to-date information and upgrades To keep your software up-to-date and to be informed about new application notes related to your software, please send an to the Customer Support Center stating your software and your wish. We will take care that you will get the right information. Europe, Africa, Middle East Phone customersupport@rohde-schwarz.com North America Phone TEST-RSA ( ) customer.support@rsa.rohde-schwarz.com Latin America Phone customersupport.la@rohde-schwarz.com Asia/Pacific Phone customersupport.asia@rohde-schwarz.com China Phone / customersupport.china@rohde-schwarz.com Release Notes

R&S ESW Test Receiver Release Notes Firmware Version V1.40 SP1

R&S ESW Test Receiver Release Notes Firmware Version V1.40 SP1 R&S ESW Test Receiver Release Notes Firmware Version V1.40 SP1 These Release Notes are for following models of the R&S ESW EMI Test Receiver: R&S ESW8, order no. 1328.4100.08 R&S ESW26, order no. 1328.4100.26

More information

R&S ESR EMI Test Receiver Release Notes Firmware Version V3.36 SP2

R&S ESR EMI Test Receiver Release Notes Firmware Version V3.36 SP2 R&S ESR EMI Test Receiver Release Notes Firmware Version V3.36 SP2 These Release Notes are for following models of the R&S EMI Test Receiver: R&S ESR3, order no. 1316.3003K03 R&S ESR7, order no. 1316.3003K07

More information

R&S RTC1002 Digital Oscilloscope Release Notes Firmware Version

R&S RTC1002 Digital Oscilloscope Release Notes Firmware Version R&S RTC1002 Digital Oscilloscope Release Notes Firmware Version 06.100 These Release Notes describe the following models and options of the R&S Digital Oscilloscope: R&S RTC1002 Digital Oscilloscope, order

More information

R&S DSA DOCSIS Signal Analyzer Release Notes Firmware Version 2.2.1

R&S DSA DOCSIS Signal Analyzer Release Notes Firmware Version 2.2.1 R&S DSA DOCSIS Signal Analyzer Release Notes Firmware Version 2.2.1 Rohde & Schwarz GmbH & Co. KG Muehldorfstr. 15, 81671 Munich, Germany Phone: +49 89 41 29-0 Fax: +49 89 41 29 12 164 E-mail: mailto:info@rohde-schwarz.com

More information

R&S RTA4000 Digital Oscilloscope Release Notes Firmware Version

R&S RTA4000 Digital Oscilloscope Release Notes Firmware Version Digital Oscilloscope Release Notes Firmware Version 01.100 These Release Notes describe the following models and options of the R&S Digital Oscilloscope: R&S RTA4004, Digital Oscilloscope order no. 1335.7700K04

More information

R&S GNSS Test Automation Release Notes Software Version 1.3.2

R&S GNSS Test Automation Release Notes Software Version 1.3.2 R&S GNSS Test Automation Release Notes Software Version 1.3.2 2018 Rohde & Schwarz GmbH & Co. KG Muehldorfstr. 15, 81671 Munich, Germany Phone: +49 89 41 29-0 Fax: +49 89 41 29 12-164 E-mail: mailto:info@rohde-schwarz.com

More information

R&S Spectrum Rider FPH Release Notes Firmware Version V1.50

R&S Spectrum Rider FPH Release Notes Firmware Version V1.50 R&S Spectrum Rider FPH Release Notes Firmware Version V1.50 2017 Rohde & Schwarz GmbH & Co. KG Muehldorfstr. 15, 81671 Munich, Germany Phone: +49 89 41 29-0 Fax: +49 89 41 29 12-164 E-mail: mailto:info@rohde-schwarz.com

More information

R&S Spectrum Rider FPH Release Notes Firmware Version V1.40

R&S Spectrum Rider FPH Release Notes Firmware Version V1.40 R&S Spectrum Rider FPH Release Notes Firmware Version V1.40 2017 Rohde & Schwarz GmbH & Co. KG Muehldorfstr. 15, 81671 Munich, Germany Phone: +49 89 41 29-0 Fax: +49 89 41 29 12-164 E-mail: mailto:info@rohde-schwarz.com

More information

R&S CMW Bluetooth Release Notes Software Version V3.2.70

R&S CMW Bluetooth Release Notes Software Version V3.2.70 R&S CMW Bluetooth Release Notes Software 2014 Rohde & Schwarz GmbH & Co. KG Muehldorfstr. 15, 81671 Munich, Germany Phone: +49 89 41 29-0 Fax: +49 89 41 29 12-164 E-mail: mailto:info@rohde-schwarz.com

More information

R&S ESU EMI Test Receiver. Release Notes. Firmware Version V5.74 SP1. Only an ESU with Windows 7 Operating System is supported

R&S ESU EMI Test Receiver. Release Notes. Firmware Version V5.74 SP1. Only an ESU with Windows 7 Operating System is supported Release Notes Test and Measurement PAD-T-M: 3574.3288.02/02.00/CI/1/EN R&S ESU EMI Test Receiver Release Notes Firmware Version V5.74 SP1 These Release Notes are for following models of the R&S EMI Test

More information

R&S AVG Pattern Import Release Notes Firmware Version 02.25

R&S AVG Pattern Import Release Notes Firmware Version 02.25 R&S AVG Pattern Import Release Notes Firmware Version 02.25 2010-2015 Rohde & Schwarz GmbH & Co. KG Muehldorfstr. 15, 81671 Munich, Germany Phone: +49 89 41 29-0 Fax: +49 89 41 29 12-164 E-mail: mailto:info@rohde-schwarz.com

More information

R&S SGT100A RF Source Base Unit Release Notes FW Version

R&S SGT100A RF Source Base Unit Release Notes FW Version R&S SGT100A RF Source Base Unit Release Notes FW Version 3.50.124.71 2017 Rohde & Schwarz GmbH & Co. KG Muehldorfstr. 15, 81671 Munich, Germany Phone: +49 89 41 29-0 Fax: +49 89 41 29 12 164 E-mail: mailto:info@rohde-schwarz.com

More information

R&S RTO and R&S RTE Oscilloscopes Release Notes Firmware Version

R&S RTO and R&S RTE Oscilloscopes Release Notes Firmware Version R&S RTO and R&S RTE Oscilloscopes Release Notes Firmware Version 3.70.1.0 These Release Notes are for following models of the R&S RTO and R&S RTE: R&S RTO 2002, order no. 1329.7002K02, R&S RTO 2004, order

More information

R&S ELEKTRA Release Notes Software Version V2.10

R&S ELEKTRA Release Notes Software Version V2.10 R&S ELEKTRA Release Notes Software V2.10 ELEMI-E 2018 Rohde & Schwarz GmbH & Co. KG Muehldorfstr. 15, 81671 Munich, Germany Phone: +49 89 41 29-0 Fax: +49 89 41 29 12-164 E-mail: mailto:info@rohde-schwarz.com

More information

R&S Pulse Sequencer DFS Software Release Notes Software Version 1.6

R&S Pulse Sequencer DFS Software Release Notes Software Version 1.6 R&S Pulse Sequencer DFS Software Release Notes Software Version 1.6 2018 Rohde & Schwarz GmbH & Co. KG Muehldorfstr. 15, 81671 Munich, Germany Phone: +49 89 41 29-0 Fax: +49 89 41 29 12-164 E-mail: mailto:info@rohde-schwarz.com

More information

R&S RTB2000 Oscilloscope Release Notes Firmware Version

R&S RTB2000 Oscilloscope Release Notes Firmware Version Oscilloscope Release Notes Firmware Version 02.202 These Release Notes describe the following models and options: R&S RTB2004 Oscilloscope, order no. 1333.1005K04 R&S RTB2002 Oscilloscope, order no. 1333.1005K02

More information

R&S Pulse Sequencer DFS Software Release Notes Software Version 1.7

R&S Pulse Sequencer DFS Software Release Notes Software Version 1.7 R&S Pulse Sequencer DFS Software Release Notes Software Version 1.7 2018 Rohde & Schwarz GmbH & Co. KG Muehldorfstr. 15, 81671 Munich, Germany Phone: +49 89 41 29-0 Fax: +49 89 41 29 12-164 E-mail: mailto:info@rohde-schwarz.com

More information

R&S RECAL + Release Notes Software Version 4.01

R&S RECAL + Release Notes Software Version 4.01 R&S RECAL + Release Notes Software Version 4.01 2018 Rohde & Schwarz GmbH & Co. KG Muehldorfstr. 15, 81671 Munich, Germany Phone: +49 89 41 29-0 Fax: +49 89 41 29 12-164 E-mail: mailto:info@rohde-schwarz.com

More information

How to Apply MS17-10 to prevent WannaCrypt Attacks

How to Apply MS17-10 to prevent WannaCrypt Attacks How to Apply MS17-10 to prevent WannaCrypt Attacks Document date: 8.8.2017 This document describes the procedure how to apply the Microsoft patches to R&S devices running Windows XP or Win7 operating systems

More information

R&S SMB100B Release Notes Firmware Version

R&S SMB100B Release Notes Firmware Version R&S SMB100B Release Notes Firmware Version 4.50.074.45 2018 Rohde & Schwarz GmbH & Co. KG Muehldorfstr. 15, 81671 Munich, Germany Phone: +49 89 41 29-0 Fax: +49 89 41 29 12-164 E-mail: mailto:info@rohde-schwarz.com

More information

R&S Broadcast Drive Test Release Notes Software Version 03.13

R&S Broadcast Drive Test Release Notes Software Version 03.13 R&S Broadcast Drive Test Release Notes Software Version 03.13 2015 Rohde & Schwarz GmbH & Co. KG Muehldorfstr. 15, 81671 Munich, Germany Phone: +49 89 41 29-0 Fax: +49 89 41 29 12 164 E-mail: mailto:info@rohde-schwarz.com

More information

How to Apply MS17-10 to prevent WannaCrypt Attacks

How to Apply MS17-10 to prevent WannaCrypt Attacks How to Apply MS17-10 to prevent WannaCrypt Attacks For Video Tester R&S VTC, R&S VTE, R&S VTS and Video Generator R&S DVSG. Document date: 2017-08-03 This document describes the procedure how to apply

More information

R&S FSVA and R&S FSV Signal and Spectrum Analyzer Release Notes Firmware Version V3.40

R&S FSVA and R&S FSV Signal and Spectrum Analyzer Release Notes Firmware Version V3.40 R&S FSVA and R&S FSV Signal and Spectrum Analyzer Release Notes Firmware Version V3.40 These Release Notes are for following models of the R&S FSVA Signal and Spectrum Analyzer: Running operating system

More information

R&S SMA100B Release Notes Firmware Version

R&S SMA100B Release Notes Firmware Version R&S SMA100B Release Notes Firmware Version 4.30.040.33 The Release Note is for the following model of the R&S SMA100B RF and Microwave Signal Generator: R&S SMA100B, order no. 1419.8888K02 2018 Rohde &

More information

R&S FPS Release Notes Firmware Version V1.50

R&S FPS Release Notes Firmware Version V1.50 R&S FPS Release Notes Firmware V1.50 These Release Notes are for following models of the R&S FPS Signal and Spectrum Analyzer: R&S FPS4, order no. 1319.2008K04 R&S FPS7, order no. 1319.2008K07 R&S FPS13,

More information

R&S WinIQSIM2 Simulation Software Release Notes Firmware Version

R&S WinIQSIM2 Simulation Software Release Notes Firmware Version R&S WinIQSIM2 Simulation Software Release Notes Firmware Version 4.00.048.23 2017 Rohde & Schwarz GmbH & Co. KG Muehldorfstr. 15, 81671 Munich, Germany Phone: +49 89 41 29-0 Fax: +49 89 41 29 12 164 E-mail:

More information

Release Notes. R&S FSC Spectrum Analyzer

Release Notes. R&S FSC Spectrum Analyzer Release Notes Revision: 02 R&S FSC Spectrum Analyzer Firmware Release 2.20 These Release Notes describe the following models and options of the R&S FSC Spectrum Analyzer: R&S Spectrum Analyzer FSC3, order

More information

R&S FSW Signal and Spectrum Analyzer

R&S FSW Signal and Spectrum Analyzer Release Notes Test and Measurement PAD-T-M: 3574.3288.02/02.00/CI/1/EN/ R&S FSW Signal and Spectrum Analyzer Release Notes Firmware Version V2.00 These Release Notes are for following models of the R&S

More information

R&S NRP-Z51/-Z52/-Z55/-Z56/- Z57/-Z58 Thermal Power Sensors Release Notes

R&S NRP-Z51/-Z52/-Z55/-Z56/- Z57/-Z58 Thermal Power Sensors Release Notes R&S NRP-Z51/-Z52/-Z55/-Z56/- Z57/-Z58 Thermal Power Sensors Release Notes 2016 Rohde & Schwarz GmbH & Co. KG 81671 Munich, Germany Printed in Germany Subject to change Data without tolerance limits is

More information

R&S TSMAx Release Notes Firmware Version

R&S TSMAx Release Notes Firmware Version R&S TSMAx Release Notes Firmware Version 03.00.11.00 2019 Rohde & Schwarz GmbH & Co. KG Muehldorfstr. 15, 81671 Munich, Germany Phone: +49 89 41 29-0 Fax: +49 89 41 29 12-164 E-mail: mailto:info@rohde-schwarz.com

More information

R&S TSMA Release Notes Firmware Version

R&S TSMA Release Notes Firmware Version R&S TSMA Release Notes Firmware Version 1.32.04.00 2018 Rohde & Schwarz GmbH & Co. KG Muehldorfstr. 15, 81671 Munich, Germany Phone: +49 89 41 29-0 Fax: +49 89 41 29 12-164 E-mail: mailto:info@rohde-schwarz.com

More information

R&S FPS Release Notes Firmware Version V1.40 SP2

R&S FPS Release Notes Firmware Version V1.40 SP2 R&S FPS Release Notes Firmware V1.40 SP2 These Release Notes are for following models of the R&S FPS Signal and Spectrum Analyzer: R&S FPS4, order no. 1319.2008K04 R&S FPS7, order no. 1319.2008K07 R&S

More information

R&S CMW500 CDMA2000 1XRTT and 1xEV-DO Release Notes Software Version

R&S CMW500 CDMA2000 1XRTT and 1xEV-DO Release Notes Software Version R&S CMW500 CDMA2000 1XRTT and 1xEV-DO Release Notes Software Version 3.2.81 2014 Rohde & Schwarz GmbH & Co. KG Muehldorfstr. 15, 81671 Munich, Germany Phone: +49 89 41 29-0 Fax: +49 89 41 29 12-164 E-mail:

More information

R&S FSW Signal and Spectrum Analyzer Release Notes Firmware Version V2.80

R&S FSW Signal and Spectrum Analyzer Release Notes Firmware Version V2.80 R&S FSW Signal and Spectrum Analyzer Release Notes Firmware Version V2.80 These Release Notes are for following models of the R&S FSW Signal and Spectrum Analyzer: R&S FSW8, order no. 1312.8000K08, R&S

More information

R&S VISA Release Notes Software Version 5.8.6

R&S VISA Release Notes Software Version 5.8.6 R&S VISA Release Notes Software Version 5.8.6 2018 Rohde & Schwarz GmbH & Co. KG Muehldorfstr. 15, 81671 Munich, Germany Phone: +49 89 41 29-0 Fax: +49 89 41 29 12-164 E-mail: mailto:info@rohde-schwarz.com

More information

Release Notes Revision: 01

Release Notes Revision: 01 Release Notes Revision: 01 R&S FSH4/FSH8/FSH13/FSH20 Handheld Spectrum Analyzer Firmware Release 2.81 These Release Notes describe the following models and options of the R&S Handheld Spectrum Analyzer:

More information

Firmware Release V1.83 SP3

Firmware Release V1.83 SP3 Test and Measurement Division Release Notes for R&S ESL EMI Test Receivers with order number: 1300.5001.xx Release Note Revision: 7 Printed in the Federal Republic of Germany Contents History... 3 General

More information

Firmware Version Build 170 SP1

Firmware Version Build 170 SP1 Test and Measurement Release Notes R&S DigIConf Software Release Notes Firmware Version 2.20.360.86 Build 170 SP1 2012 Rohde & Schwarz GmbH & Co. KG 81671 Munich, Germany Printed in Germany Subject to

More information

R&S DigIConf Software Release Notes Firmware Version Build 170 SP1

R&S DigIConf Software Release Notes Firmware Version Build 170 SP1 R&S DigIConf Software Release Notes Firmware Version 2.20.360.86 Build 170 SP1 2012 Rohde & Schwarz GmbH & Co. KG 81671 Munich, Germany Printed in Germany Subject to change Data without tolerance limits

More information

How to deal with the effects of CVE

How to deal with the effects of CVE How to deal with the effects of CVE-2018-0886 Restore Remote Access to R&S instruments V 2.10 Document date: 26.06.2018 This document describes possible ways to access R&S instruments after the security

More information

R&S ETL TV Analyzer Release Notes Firmware Version 3.40

R&S ETL TV Analyzer Release Notes Firmware Version 3.40 R&S ETL TV Analyzer Release Notes Firmware Version 3.40 2018 Rohde & Schwarz GmbH & Co. KG Muehldorfstr. 15, 81671 Munich, Germany Phone: +49 89 41 29-0 Fax: +49 89 41 29 12 164 E-mail: mailto:info@rohde-schwarz.com

More information

R&S AVBrun Sequencer Software. Release Notes. Firmware Version Release Notes. Broadcasting

R&S AVBrun Sequencer Software. Release Notes. Firmware Version Release Notes. Broadcasting Release Notes Broadcasting PAD-T-M: 3574.3288.02/02.00/CI/1/EN/ R&S AVBrun Sequencer Software Release Notes Firmware Version 01.93 2012-2016 Rohde & Schwarz GmbH & Co. KG Muehldorfstr. 15, 81671 Munich,

More information

R&S FSL Spectrum Analyzer Resolving Security Issues When Working in Secure Areas

R&S FSL Spectrum Analyzer Resolving Security Issues When Working in Secure Areas Spectrum Analyzer Resolving Security Issues When Working in Secure Areas Based upon the user s security requirements, this document describes the Rohde&Schwarz options available to address the user s spectrum

More information

R&S NRPV Virtual Power Meter Release Notes Application Version 3.2

R&S NRPV Virtual Power Meter Release Notes Application Version 3.2 R&S NRPV Virtual Power Meter Release Notes Application Version 3.2 2011-2017 Rohde & Schwarz GmbH & Co. KG 81671 Munich, Germany Subject to change Data without tolerance limits is not binding. R&S is a

More information

R&S QuickStep Test Executive Software Flexibility and excellent performance

R&S QuickStep Test Executive Software Flexibility and excellent performance Product Brochure Version 05.00 R&S QuickStep Test Executive Software Flexibility and excellent performance QuickStep_bro_en_3607-2249-12_v0500.indd 1 21.12.2017 16:45:09 R&S QuickStep Test Executive Software

More information

R&S FSW Signal and Spectrum Analyzer Release Notes Firmware Version V3.10

R&S FSW Signal and Spectrum Analyzer Release Notes Firmware Version V3.10 R&S FSW Signal and Spectrum Analyzer Release Notes Firmware Version V3.10 These Release Notes are for following models of the R&S FSW Signal and Spectrum Analyzer: R&S FSW8, order no. 1312.8000K08, R&S

More information

R&S FSW Signal and Spectrum Analyzer Release Notes Firmware Version V4.21

R&S FSW Signal and Spectrum Analyzer Release Notes Firmware Version V4.21 R&S FSW Signal and Spectrum Analyzer Release Notes Firmware Version V4.21 These Release Notes are for following models of the R&S FSW Signal and Spectrum Analyzer: R&S FSW8, order no. 1331.5003K08, R&S

More information

R&S FSW Signal and Spectrum Analyzer Release Notes Firmware Version V4.30SP1

R&S FSW Signal and Spectrum Analyzer Release Notes Firmware Version V4.30SP1 R&S FSW Signal and Spectrum Analyzer Release Notes Firmware Version V4.30SP1 These Release Notes are for following models of the R&S FSW Signal and Spectrum Analyzer: R&S FSW8, order no. 1331.5003K08,

More information

Release Notes. Revision: 01. R&S FSH4/FSH8/FSH13/FSH20 Handheld Spectrum Analyzer. Firmware Release 2.40

Release Notes. Revision: 01. R&S FSH4/FSH8/FSH13/FSH20 Handheld Spectrum Analyzer. Firmware Release 2.40 R&S FSH4/FSH8/FSH13/FSH20 Handheld Spectrum Analyzer Release Notes Revision: 01 R&S FSH4/FSH8/FSH13/FSH20 Handheld Spectrum Analyzer Firmware Release 2.40 These Release Notes describe the following models

More information

R&S Power Meter NRP Release Notes Firmware Version

R&S Power Meter NRP Release Notes Firmware Version R&S Power Meter NRP Release Notes Firmware Version 06.03.020 2011 Rohde & Schwarz GmbH & Co. KG 81671 Munich, Germany Printed in Germany Subject to change Data without tolerance limits is not binding.

More information

R&S InstrumentView Spectrum Analyzer Software Manual

R&S InstrumentView Spectrum Analyzer Software Manual R&S InstrumentView Spectrum Analyzer Software Manual (=E:X2) Software Manual 1321.1040.02 04.00 The software manual describes the following: R&S InstrumentView The R&S InstrumentView supports the following

More information

Replacing R&S CMU200 with R&S CMW500 in 2G and 3G Speech Test Applications Application Note

Replacing R&S CMU200 with R&S CMW500 in 2G and 3G Speech Test Applications Application Note Replacing R&S CMU200 with R&S CMW500 in 2G and 3G Speech Test Applications Thomas Lechner, 1GPM 17-Jul-14- Replacing R&S CMU200 with R&S CMW500 in 2G and 3G Speech Test Applications Application Note Products:

More information

R&S MSD Modular System Device Flexible antenna switching and rotator control

R&S MSD Modular System Device Flexible antenna switching and rotator control MSD_bro_en_3606-7082-12_v0300.indd 1 Product Brochure 03.00 Radiomonitoring & Radiolocation Modular System Device Flexible antenna switching and rotator control 28.10.2015 12:46:19 Modular System Device

More information

Firmware Release V2.40

Firmware Release V2.40 Test and Measurement Division Release Notes Firmware Release V2.40 for R&S FSL Spectrum Analyzers with order number: 1300.2502.xx New Features of V2.20: Support for Power Sensors R&S NRP-Z211 and R&S NRP-Z221

More information

BitLocker White Paper Windows 10

BitLocker White Paper Windows 10 BitLocker White Paper Windows 10 This white paper gives detailed instructions how to enable BitLocker on a measurement device. BitLocker White Paper Windows 10 7.2018 1178.8859.02-01 Table of Contents

More information

R&S InstrumentView Software Manual

R&S InstrumentView Software Manual R&S InstrumentView Software Manual (=E:X2) Version 06.00 1321104002 The software manual describes the following: R&S InstrumentView The R&S InstrumentView supports the following product series: R&S FPH

More information

R&S InstrumentView Software Manual

R&S InstrumentView Software Manual R&S InstrumentView Software Manual (=E:X2) Version 07.00 1321104002 The software manual describes the following: The supports the following product series: R&S FPH R&S ZPH R&S FPC R&S FSH4 R&S ZVH R&S

More information

R&S NRP-Z27/-Z37 Power Sensor Module Release Notes Firmware Version 04.18a

R&S NRP-Z27/-Z37 Power Sensor Module Release Notes Firmware Version 04.18a R&S NRP-Z27/-Z37 Power Sensor Module Release Notes Firmware Version 04.18a 2010 Rohde & Schwarz GmbH & Co. KG 81671 Munich, Germany Printed in Germany Subject to change Data without tolerance limits is

More information

Resolving Security Issues When Working with the R&S ESIB in Secure Areas

Resolving Security Issues When Working with the R&S ESIB in Secure Areas Products: R&S EMI Test Receiver ESIB Resolving Security Issues When Working with the R&S ESIB in Secure Areas Based upon the user s requirements, this document describes the Rohde&Schwarz options available

More information

LabVIEW driver history for the R&S HMC8012 Driver Documentation

LabVIEW driver history for the R&S HMC8012 Driver Documentation LabVIEW driver history for the R&S HMC8012 Driver Documentation Products: R&S HMC8012 Driver history for LabVIEW Miloslav Macko July 26, 2017 Table of Contents Table of Contents 1 Supported Instruments...

More information

IEEE Testing Signal Compliance of ZigBee Standard

IEEE Testing Signal Compliance of ZigBee Standard IEEE802.15.4 Testing Signal Compliance of ZigBee Standard Tektronix 1 Agenda: 1: What is ZigBee 2: ZigBee Specification 3: ZigBee Signal Analysis 4: Demonstration for ZigBee analysis 2 What is ZigBee (1)

More information

TD-SCDMA Mobile Station Test Application Firmware R&S FS-K77

TD-SCDMA Mobile Station Test Application Firmware R&S FS-K77 Test and Measurement Division Release Notes TD-SCDMA Mobile Station Test Application R&S FS-K77 Release 4.10 for R&S FSP, FSU, FSQ, FMU, FSUP Analyzer 4.1x New Features: High Dynamic Power vs. Time Measurement

More information

R&S ELEKTRA EMC Test Software Swift and reliable measurement of electromagnetic disturbances

R&S ELEKTRA EMC Test Software Swift and reliable measurement of electromagnetic disturbances R&S ELEKTRA EMC Test Software Swift and reliable measurement of electromagnetic disturbances Product Brochure Version 01.01 R&S ELEKTRA EMC Test Software At a glance The R&S ELEKTRA EMC test software is

More information

TopSec Mobile Secure voice encryption for smartphones and laptops

TopSec Mobile Secure voice encryption for smartphones and laptops Secure Communications Product Brochure 02.00 TopSec Mobile Secure voice encryption for smartphones and laptops TopSec Mobile At a glance The TopSec Mobile is a mobile encryption device for secure worldwide

More information

R&S DVMS DTV Monitoring System Release Notes Firmware Version

R&S DVMS DTV Monitoring System Release Notes Firmware Version R&S DVMS DTV Monitoring System Release Notes Firmware Version 02.72.0 2017 Rohde & Schwarz GmbH & Co. KG Muehldorfstr. 15, 81671 Munich, Germany Phone: +49 89 41 29-0 Fax: +49 89 41 29 12 164 E-mail: mailto:info@rohde-schwarz.com

More information

R&S SMW200A Creating Tutorials and Interactive Examples Application Sheet

R&S SMW200A Creating Tutorials and Interactive Examples Application Sheet Creating Tutorials and Interactive Examples Application Sheet (;ÜT;2) 1178.3611.02 04 Test & Measurement Application Sheet This manual describes firmware version FW 3.20.459.xx and later of the R&S SMW200A.

More information

R&S SFC / SFC-U / VT-B600 Compact Modulator / USB Compact Modulator / Broadcast TX Modulator Release Notes Firmware Version 02.96

R&S SFC / SFC-U / VT-B600 Compact Modulator / USB Compact Modulator / Broadcast TX Modulator Release Notes Firmware Version 02.96 R&S SFC / SFC-U / VT-B600 Compact Modulator / USB Compact Modulator / Broadcast TX Modulator Release Notes Firmware Version 02.96 2012-2017 Rohde & Schwarz GmbH & Co. KG Muehldorfstr. 15, 81671 Munich,

More information

R&S ETL TV Analyzer Release Notes Firmware Version 3.51

R&S ETL TV Analyzer Release Notes Firmware Version 3.51 R&S ETL TV Analyzer Release Notes Firmware Version 3.51 2018 Rohde & Schwarz GmbH & Co. KG Muehldorfstr. 15, 81671 Munich, Germany Phone: +49 89 41 29-0 Fax: +49 89 41 29 12 164 E-mail: mailto:info@rohde-schwarz.com

More information

R&S LXI Class C Support V1.21 (XP)

R&S LXI Class C Support V1.21 (XP) Test and Measurement Division Release Notes for R&S LXI Class C Support V1.21 (XP) R&S FSP Spectrum Analyzers R&S FSU Spectrum Analyzers R&S FSG Signal Analyzers R&S FSQ Signal Analyzers Printed in the

More information

Release Note for LTE Measurement

Release Note for LTE Measurement Release Note 3.2.80 for LTE Measurement New Features compared to version 3.2.70: PUCCH / PUSCH / SRS time mask and SRS blanking time mask also for TDD Peak values of the EVM vs subcarrier trace are available

More information

3G FDD BTS/3GPP HSDPA BTS

3G FDD BTS/3GPP HSDPA BTS Test and Measurement Division Release Notes 3G FDD BTS/3GPP HSDPA BTS Application R&S FS-K72/FS-K74 Release 4.17 for R&S FSUP Analyzer 4.17 Release Note Revision: 1 Printed in the Federal Republic of Germany

More information

Release Notes. R&S ES-SCAN EMI Measurement Software

Release Notes. R&S ES-SCAN EMI Measurement Software Release Notes Revision: 09 R&S ES-SCAN EMI Measurement Software Software Release V2.70 These Release Notes describe the following types and options of the R&S ES-SCAN EMI Measurement Software. R&S ES-SCAN,

More information

1xEV-DO Mobile Station Test

1xEV-DO Mobile Station Test Test and Measurement Division Release Notes 1xEV-DO Mobile Station Test Application R&S FS-K85 Release 4.10 for R&S FSP, FSU, FSQ, FMU, FSUP Analyzer 4.1x Release Note Revision: 2 Printed in the Federal

More information

Application Firmware R&S FS-K5 Release for R&S FSP, FSU, FSQ, FMU, FSUP Analyzer Firmware 4.1x

Application Firmware R&S FS-K5 Release for R&S FSP, FSU, FSQ, FMU, FSUP Analyzer Firmware 4.1x Test and Measurement Division Release Notes GSM/EDGE Application Firmware R&S FS-K5 Release 4.10 for R&S FSP, FSU, FSQ, FMU, FSUP Analyzer Firmware 4.1x New Features: Extended Configuration Mode for mixed

More information

TSML-W Radio Network Analyzer

TSML-W Radio Network Analyzer Version 02.00 TSML-W Radio Network Analyzer February 2007 WCDMA PN scanner WCDMA PN scanning (bands I to IX) with BCH (SIB) demodulation Low power consumption Attractive pricing Handy, portable, and compact

More information

Voice Quality Measurements with R&S ROMES. Application Note

Voice Quality Measurements with R&S ROMES. Application Note Voice Quality Measurements with R&S ROMES Application Note 1SP52 Products: R&S ROMES This document introduces Voice Quality Measurements with R&S ROMES and describes the configuration of the drive test

More information

cdma2000/1xev-dv Mobile Station Test

cdma2000/1xev-dv Mobile Station Test Test and Measurement Division Release Notes cdma2000/1xev-dv Mobile Station Test Application R&S FS-K83 Release 4.10 for R&S FSP, FSU, FSQ, FMU, FSUP Analyzer 4.1x Release Note Revision: 2 Printed in the

More information

.NET programming interface for R&S GTSL and R&S EGTSL

.NET programming interface for R&S GTSL and R&S EGTSL Application Note 2.2016 SE001_0e.NET programming interface for R&S GTSL and R&S EGTSL Application Note Products: ı R&S CompactTSVP ı R&S PowerTSVP ı R&S GTSL ı R&S EGTSL This application note describes

More information

Simple Sequencing Tool for SCPI Commands Application Note

Simple Sequencing Tool for SCPI Commands Application Note Simple Sequencing Tool for SCPI Commands Application Note Products: R&S UPV R&S UPV-K1 This document describes an application program for sending a sequence of logged SCPI commands to the firmware of the

More information

N7624B Signal Studio for LTE Technical Overview

N7624B Signal Studio for LTE Technical Overview N7624B Signal Studio for LTE Technical Overview Easily Create Sophisticated LTE Test Waveforms 3GPP Long Term Evolution (LTE) defines improvements to UMTS to provide increased system efficiency, including

More information

Firmware Release 2.4

Firmware Release 2.4 Test and Measurement Division Release Notes Firmware Release 2.4 for R&S UP300/350 Audio Analyzer Contents 1. General Topics... 3 1.1. Firmware Update Overview...3 System Requirements...3 Update file set...3

More information

R&S SMBV100B Release Notes Firmware Version

R&S SMBV100B Release Notes Firmware Version R&S SMBV100B Release Notes Firmware Version 4.50.074.45 2018 Rohde & Schwarz GmbH & Co. KG Muehldorfstr. 15, 81671 Munich, Germany Phone: +49 89 41 29-0 Fax: +49 89 41 29 12-164 E-mail: mailto:info@rohde-schwarz.com

More information

TopSec Product Family Voice encryption at the highest security level

TopSec Product Family Voice encryption at the highest security level Secure Communications Product Brochure 01.01 TopSec Product Family Voice encryption at the highest security level TopSec Product Family At a glance The TopSec product family provides end-to-end voice encryption

More information

R&S RTO-K81, R&S RTP-K81 PCIe Compliance Test Test Procedures

R&S RTO-K81, R&S RTP-K81 PCIe Compliance Test Test Procedures PCIe Compliance Test Test Procedures (=QFñ2) 1333229902 Test Procedures Version 03 This manual describes the PCIe compliance test procedures with the following options: R&S RTO-K81 (1326.0920.02) - PCIe

More information

R&S SMB100A Release Notes Firmware Version

R&S SMB100A Release Notes Firmware Version R&S SMB100A Release Notes Firmware Version 3.20.390.24 2016 Rohde & Schwarz GmbH & Co. KG Muehldorfstr. 15, 81671 Munich, Germany Phone: +49 89 41 29-0 Fax: +49 89 41 29 12-164 E-mail: mailto:info@rohde-schwarz.com

More information

R&S SFQ to R&S SFU SCPI Transcription + Cross-Reference List

R&S SFQ to R&S SFU SCPI Transcription + Cross-Reference List SCPI Broadcast Test System: R&S SFU R&S SFQ to R&S SFU SCPI Transcription + Cross-Reference List Application Note For customers who have already used automated R&S SFQ setups in development and production,

More information

R&S ZN-Z15x Calibration Units User Manual

R&S ZN-Z15x Calibration Units User Manual R&S ZN-Z15x Calibration Units User Manual (=UÉÍ2) Version 02 User Manual 1337596302 This User Manual describes the following R&S ZN-Z15x models: R&S ZN-Z150, N (f), 2 ports, 5 khz to 6 GHz (1335.6710.72)

More information

R&S Browser in the Box Release Notes

R&S Browser in the Box Release Notes R&S Browser in the Box 2017-07-07 2017 Rohde & Schwarz GmbH & Co. KG Muehldorfstr. 15, 81671 Munich, Germany Phone: +49 89 41 29-0 Fax: +49 89 41 29 12-164 E-mail: mailto:info@rohde-schwarz.com Internet:

More information

R&S ScopeSuite Release Notes Software Version 3.6.0

R&S ScopeSuite Release Notes Software Version 3.6.0 R&S Release Notes Software Version 3.6.0 2017 Rohde & Schwarz GmbH & Co. KG Muehldorfstr. 15, 81671 Munich, Germany Phone: +49 89 41 29-0 Fax: +49 89 41 29 12-164 E-mail: mailto:info@rohde-schwarz.com

More information

PC Software R&S FS300-K1

PC Software R&S FS300-K1 Copyright 0 Copyright Copyright Licence Agreement Rohde & Schwarz grants you the right to install the R&S FS300-K1 software package on one or more PCs of your choice. The licence included in the software

More information

R&S FSH4/8/13/20 Spectrum Analyzer Quick Start Guide

R&S FSH4/8/13/20 Spectrum Analyzer Quick Start Guide R&S FSH4/8/13/20 Spectrum Analyzer Quick Start Guide 1309.6269.12 07 Test & Measurement Quick Start Guide The Operating Manual describes the following R&S FSH models and options: R&S FSH4 (1309.6000.04)

More information

AFS: Feb, ESC support to vector X-Series MXG/EXG. 40 MHz analysis BW w/ MPB on mmw EXA Opt DP2 on mmw EXA Windows 7 support (M/EXA)

AFS: Feb, ESC support to vector X-Series MXG/EXG. 40 MHz analysis BW w/ MPB on mmw EXA Opt DP2 on mmw EXA Windows 7 support (M/EXA) Firmware Rev. Firmware Rev. Enhancements on X-Series analyzers AFS: May, 2012 Millimeter EXA introduction 32 and 44 GHz frequency options Optional 32 and 44 GHz internal preamp Option EXM on mmw EXA AFS:

More information

N4010A Wireless Connectivity Test Set Firmware Revision History

N4010A Wireless Connectivity Test Set Firmware Revision History N4010A Wireless Connectivity Test Set Firmware Revision History November 17 th 2009 Revision A.05.03.14 November 12 th 2009 - Maintenance release The latest Firmware Upgrade Utility (version 2.0.16) is

More information

PSA-Manager Version 3 User Manual

PSA-Manager Version 3 User Manual PSA-Manager Version 3 User Manual CONTENTS 1 Introduction...2 2 File Types and Locations...3 3 PSA-Manager Windows...4 4 Viewing Trace Files...7 4.1.1 The Trace Memo sub-window...8 4.1.2 Printing Trace

More information

LabVIEW driver history for the R&S Spectrum Analyzers 2.x Driver Documentation

LabVIEW driver history for the R&S Spectrum Analyzers 2.x Driver Documentation LabVIEW driver history for the R&S Spectrum Analyzers 2.x Driver Documentation Products: R&S FSP R&S FMU R&S FSU R&S FSG R&S FSQ R&S FSL Miloslav Macko March 26, 2018 Table of Contents Table of Contents

More information

Floppy Disk Control of the I/Q Modulation Generator AMIQ

Floppy Disk Control of the I/Q Modulation Generator AMIQ Products: I/Q Modulation Generator AMIQ, WinIQSIM, SMIQ Floppy Disk Control of the I/Q Modulation Generator AMIQ The I/Q Modulation Generator AMIQ is best controlled by the software package WinIQSIM. However,

More information

R&S NGE100 Power Supply Series Reduced to the max

R&S NGE100 Power Supply Series Reduced to the max R&S NGE100 Power Supply Series Reduced to the max year Product Brochure Version 01.01 R&S NGE100 Power Supply Series At a glance The R&S NGE100 power supply series consists of robust, high-performance,

More information

CPRI RF Analyzer and BBU Emulator

CPRI RF Analyzer and BBU Emulator Measurement Guide CPRI RF Analyzer and BBU Emulator for Anritsu RF and Microwave Handheld Instruments CPRI Common Public Radio Interface BBU Base Band Unit Anritsu Company 490 Jarvis Drive Morgan Hill,

More information

Keysight Technologies 89601B/BN-BHJ WLAN n/ac Modulation Analysis 89601B/BN-BHX WLAN ax Modulation Analysis VSA Software

Keysight Technologies 89601B/BN-BHJ WLAN n/ac Modulation Analysis 89601B/BN-BHX WLAN ax Modulation Analysis VSA Software Keysight Technologies 89601B/BN-BHJ WLAN 802.11n/ac Modulation Analysis 89601B/BN-BHX WLAN 802.11ax Modulation Analysis 89600 VSA Software Technical Overview Perform measurements on the latest IEEE 802.11ax

More information

LabWindows/CVI, VXIpnp driver history for the R&S RTM2000 Digital Oscilloscopes

LabWindows/CVI, VXIpnp driver history for the R&S RTM2000 Digital Oscilloscopes Miloslav Macko January 25, 2017 LabWindows/CVI, VXIpnp driver history for the R&S RTM2000 Digital Oscilloscopes Products: R&S RTM20xx Driver history for LabWindows/CVI and VXIplug&play Instrument Driver

More information