HYDRO. «f. Formation Pressure Worksheet. Well no 7228/9-1 Pressure. RKB-MSL 23.5 m Rig Ross Rigg. Witnessed/ by Dons/Eide. Page. 2 of 3. Date

Size: px
Start display at page:

Download "HYDRO. «f. Formation Pressure Worksheet. Well no 7228/9-1 Pressure. RKB-MSL 23.5 m Rig Ross Rigg. Witnessed/ by Dons/Eide. Page. 2 of 3. Date"

Transcription

1 «f. HYDRO Formation Pressure Worksheet Well no / Pressure units Bar A RKBMSL. m Rig Ross Rigg Witnessed/ by Dons/Eide ge of Run no./ Test no. Depth (MD) mrkb IHP FP FHP Permability remarks B/ Good B/ Fair B/... Fair B/ Fair B/ Fair B/ Good B/ Mistest B/A Very good B/.0... Very good B/..0. Nil B/ Moderate B/ Moderate B/.0. «? Very poor B/.. Moderate? B/ Moderate? B/.0.0 Retracted too soon B/ Very poor B/ 0.0. B/ Very poor B/.0.. B/0.0.. B/ 0... B/.0. Seal f ailture B/... B/.0.. B/.0.. B/.0... Poor B/.0..0 B/

2 CO. HYDRO Formation Pressure Worksheet Well no / Pressure units Bar A RKBMSL. m Rig Ross Rigg Witnessed/ by Dons/Eide ge of Run no./ Test no. Depth (MD) mrkb IHP FP FHP Permability remarks B/ Seal failture B/ Seal failture Segreated sample B/.... Moderate pretest

3 Formation Fluid Sampling wen NO.: / : Pretest No.: + Sample depth: 0, m Witnesses: Dons/Eide Run No.: A Sample No.: A st Chamber nd Chamber rd Chamber Chamber volume (gals./litres) GAL =, Gal =, I Chamber No. RFS0 Filling time (mins) min min Shut in pressure (BAR)/T C,0/.0/, / Chamber pressure (surface BAR)/T C No Pressure/* Sealed / / Gas volume (SCF/Sm ) 0 cm Oil volume (litres) 0* Oil gravity (AAPI/gm/cc) Water/Filtrate (litres) 0! Water/Filtrate PPM C K + = Water filtrate ph/pf/ca ++PPM, / 0 / 0 / / / / filtrate PPM C" 000 / / / / filtrate ph/pf/ca^ K + = 000,/0,/00 Gas composition C C C IC NC HS CO PPM 0,0,0, 0, 0 0,0 None * Remarks: Chokes used: x 0,00" 0 min filling time for gal. Draw down pressure:, bar on gal, bar on gal * No pressure on surface when opening gal chamber. Only 0 cc gass collected in ballon in front of water when draining gal. * Possible micron thick film of "oil" floating on water, but may well be contamination. * Good smell of "rotten eggs" from gal water, but no H S registered on H S meter. Water resistivity measured by Schlumberger to 0.0 ohmm < > C

4 Depth (m RKB) Res.press. (bars) Res.temp. ( C) Resistiv. ohmm (at 0 C) Density (/cc) Content of Cations and Anions (mg/l) Sodium Potassium : Calcium : Magnesium : Strontium : Barium Iron Chloride : Sulfate RFT run no. A Depth (m RKB) 0.0 Res.press. (bars).0 Res.temp. Resistiv. ohmm Density ( C) (at 0 C) (g/cc) Content of Cations and Anions (mg/l) Sodium : 0.0 Potassium : 00.0 Calcium :.0 Magnesium : 0 Strontium :.0 Barium Iron :. 0.0 Chloride : 0.0 Sulfate : 00.0 Bicarbonate : 0.0 RFT run no. B Formation water analysis, RFT run no. A and B HYDRO

5 Depth (m RKB) Res.press. (bars) Res.temp. ( C) Gas/water ratio Gas gravity (SrrvVSm ) {air= ) Fraction N CO C C C ic nc ic nc C C C C C0 Weight () Mole () Gas analysis, RFT run no. B HYDRO

6 TABLE B0 0 ((( Norsk Well Data Dai : / Contractor: : "Mid depth y ra P R O M U D " f r o m u d System table P, r o p e r t i e s BORE otherwise from table. / Mid. depth m,md Dens. (SG) PV cp YP GEL 0 GEL 0 PH psi HP/HT Clinn/out mg/ 0/ 0/ 0/ 0/ 0/ 0000/ 0000/ / 000/ 000/ 000/ 000/ 000/ 000/ 000/ 000/ 000/ 000/ 000/ Alk Pf ilini Pra ty Mf Ca++ inn/out mg/ 0/ 0/ 0/ 0/ 0/ 0/ 0/ 00/ 00/ 0/ 0/ 0/ Oil Sol H0 V.G so 0 me 00 rpra :er 00 0 at F 0 0 Type CMC CMC CMC PAC POLYMER POLYMER KCL/ POLYMER

7 fi ((( Norsk Well Data Daily mud System : / Contractor: PROMUD : "Mid depth" from table P, ropert BORE otherwise i e s from table / Mid. depth m,md Dens. (SG) PV cp YP GEL 0 GEL 0 ph psi HP/HT Clinn/out mg/ 0000/ 000/ 000/ / / / / /00 000/ / 000/ 0000/ 00/ 000/ 000/ 000/ 00/ 000/ 000/ 000/ 000/ 000/ 000/ 000/ 000/ 000/ 000/ 000/ 000/ 000/ 000/ 000/ 000/ 000/ 000/ 000/ 000/ 000/ 000/ 000/ 00/ 000/ 000/ Alki Pf ilinii Pm y Mf Ca++ inn/out mg/ 0/ 00/ 00/ 0/ 0/ 0/ 0/ 0/ 0/ 00/ 00/ 0/ 00/ 00/ 0/ 00/ 00/ 00/ 00/ 00/ 0/ 0/ 0/ 0/ 0/ 0/ 00/ 00/ 0/ 0/ 0/ 00/ 0/ 00/ 0/ 0/ 0/ 0/ 0/ 0/ 0/ 0/ 0/ Oil Sol H0 V.G me er at 00 0 \ * r. F 0 Type KCL/PAC/PAH

8 ((( Norsk Daily mud p r o p e r t i e s System : BORE Well: / Contractor: PROMUD Data: "Mid depth" from table, otherwise from table Mid. depth m,md Dens. (SG) PV cp YP GEL 0 GEL 0 ph psi HP/HT Clinn/out rag/ 000/ 000/ 000/ 000/ 000/ 000/ 000/ 000/ 000/ 000/ 000/ 000/ 000/ 000/ 000/ 000/ 000/ 000/ 000/ 000/ 000/ 000/ 000/ 000/ 000/ 000/ 000/ 000/ 000/ 000/ 000/ 000/ 000/ / 000/ 000/ 000/ 000/ 000/ 000/ 000/ 000/ 000/ /0. Alk< Pf ilinil Pm , Mf Ca++ inn/out mg/ 0/ 0/ 0/ 0/ 0/ 0/ 0/ 0/ 0/ 0/ 0/ 0/ 0/ 0/ 0/ 0/ 0/ 0/ 00/ 00/ 0/ / 00/ 00/ 0/ 00/ 00/ 0/ 0/ 0/ 0/ 0/ 0/0 0/ 0/ 0/ 0/ 0/ 0/ 00/ 00/ 0/ 0/ Oil Sol HO V.G me 00 :er 00 it 00 f «r. F Type

9 ((( Norsk Daily mud p r o p e r t i e s System : BORE Well: / Contractor: PROMUD Data: "Mid depth" from table, otherwise from table. /0. Mid. depth m,md Dens. (SG) PV cp YP GEL 0 GEL 0 PH 00 psi HP/HT Clinn/out mg/ Alkeiliniiy Pf Pin Mf Ca++ inn/out rag/ Oil Sol H0 V.G 00 me per it 00 \ «r. F Type / 000/ 000/ 000/ 000/ 000/ 000/ o o o o o co «o co co co 0/ 0/ KCL/P0LYMER

10 TABLE Bll Norsk Well: / company: PROMUD c o n s u m p t i o n System : BORE /0 Actual used Drilling of hole BARITE BENTONITE CAUSTIC SODA CMC HI VIS KWIC SEAL MICA PAC POLYMER REG POTASSIUM BRINE POTASSIUM CL PROCAP SODA ASH WALLNUT XANTAN POLYMER BACTERIOCIDE Drilling of " BARITE BENTONITE CAUSTIC SODA CMC HI VIS PAC POLYMER REG POTASSIUM BRINE PROCAP SODA ASH BACTERIOCIDE Drilling of /" BARITE BENTONITE CAUSTIC SODA PAC POLYMER REG PAC POLYMER S POTASSIUM BRINE POTASSIUM CL PROCAP SODA ASH XANTAN POLYMER XC POLYMER BACTERIOCIDE Drilling of l/ tf hole hole hole BARITE CAUSTIC SODA LUBRICANT 000

11 M u d c o n s u m p t (((.» System : BORE _ Wa T)fi/Q Norsk company: PROMUD ion PAC POLYMER REG PAC POLYMER S PAC POLYMER SL POTASSIUM BRINE POTASSIUM CL PROCAP SODA ASH SODIUM BICARB SODIUMBICARB THERMOPOL BACTERIOCIDE LIQUID DEFOAMER Drilling of BARITE CAUSTIC SODA PAC POLYMER REG PAC POLYMER S POTASSIUM CL PROCAP PRODEFOAM PROPOL REG SODA ASH SODIUM BICARB SODIUM CHLORIDE THERMOPOL WALLNUT LIQUID DEFOAMER Plug and Abandon /" hole Actual used BACTERIOCIDE 00

French Creek Software, Inc. Quick Start Guide

French Creek Software, Inc. Quick Start Guide French Creek Software, Inc Quick Start Guide Inside This Guide Section 1: Setup - Overview & Install 4 Software Overview System Requirements 5 Installation Section 2: Getting Around - Get to Modeling 7

More information

Geotech Services, X-18, MIDC, Hingna, Nagpur, Maharashtra. Discipline Chemical Testing Issue Date

Geotech Services, X-18, MIDC, Hingna, Nagpur, Maharashtra. Discipline Chemical Testing Issue Date Last Amended on 11.01.2014 Page 1 of 6 I. WATER 1. WATER (For Construction Purpose Only) ph Value IS 3025 (Part 11) : 1983 (Clause 2.0) Suspended Matter IS 3025 (Part 17) : 1984 Organic matter IS 3025

More information

Stackable with all of Tucker Technologies Integra Suite Logging tools 1

Stackable with all of Tucker Technologies Integra Suite Logging tools 1 Industry Leading Coverage: Industry Leading Vertical Resolution: Higher Sample Rates: 84% in a 8 inch Borehole 0.15 Vertical Resolution Up to 500 samples per foot Stackable with all of Tucker Technologies

More information

PARTICIPANT STATISTICS Chemistry Q Chemistry i-stat. Specimen 1 Specimen 2 Specimen 3 Specimen 4 Specimen 5

PARTICIPANT STATISTICS Chemistry Q Chemistry i-stat. Specimen 1 Specimen 2 Specimen 3 Specimen 4 Specimen 5 PARTICIPANT STATISTICS Chemistry Q 20 Chemistry i-stat Name Bicarbonate (Total CO2) - istat 25.0-37.0 P 30.9..0-9.0 C 5.4 0.7 8.0-26.0 P 22. 0.4 24.0-35.0 P 29.4.0 39.0-58.0 P 48.3.7 9 24.0-36.0 P 30..6.0-9.0

More information

PETROPHYSICAL DATA AND OPEN HOLE LOGGING BASICS COPYRIGHT. MWD and LWD Acquisition (Measurement and Logging While Drilling)

PETROPHYSICAL DATA AND OPEN HOLE LOGGING BASICS COPYRIGHT. MWD and LWD Acquisition (Measurement and Logging While Drilling) LEARNING OBJECTIVES PETROPHYSICAL DATA AND OPEN HOLE LOGGING BASICS MWD and LWD Acquisition By the end of this lesson, you will be able to: Understand the concept of Measurements While Drilling (MWD) and

More information

Drilling & Completion Summary - Ascending

Drilling & Completion Summary - Ascending API/UWI 42-383-37797-0000 Property Sub 927369-010 Field Name SPRABERRY (TREND AREA) Spud TD 8/15/2012 8/24/2012 Ground Elevation (ft) Original KB Elevation (ft) 2,625.00 2,640.00 PBTD (All) (ftkb) Original

More information

TitrIC Vario pro. Multi parameter analysis by titration and ion chromatography combined

TitrIC Vario pro. Multi parameter analysis by titration and ion chromatography combined TitrIC Vario pro Multi parameter analysis by titration and ion chromatography combined TitrIC Vario pro the dream team for comprehensive ion analysis 02 Comprehensive analysis of ionic components in liquid

More information

USER MANUAL IONPURE IONPURE IP-PRO ONLINE IP-PRO ONLINE. IP-MAN-IP-PRO-OL August Revision 1

USER MANUAL IONPURE IONPURE IP-PRO ONLINE IP-PRO ONLINE. IP-MAN-IP-PRO-OL August Revision 1 10 Technology Drive Lowell, Massachusetts 01851 Tel: (866) 876-3340 Fax: (978) 934-9499 www.ionpure.com IONPURE IP-PRO ONLINE USER MANUAL IP-MAN-IP-PRO-OL August 2017 Revision 1 Page 1 Table of Contents

More information

Level- and temperature sensor Nivotemp NT M-XP

Level- and temperature sensor Nivotemp NT M-XP Level- and temperature sensor Nivotemp NT M-XP Fluidcontrol In hydraulics and lubrication technology the fill level of oil tanks needs to be monitored continuously. Here, modern factory automation requires

More information

Level- and temperature sensor Nivotemp NT 67-XP

Level- and temperature sensor Nivotemp NT 67-XP Level- and temperature sensor Nivotemp NT 67-XP Fluidcontrol In hydraulics and lubrication technology the fill level of oil tanks needs to be monitored continuously. Here, modern factory automation requires

More information

Integrity Objects Schematics User Guide

Integrity Objects Schematics User Guide Alfadata Technologies Corporation Integrity Objects Schematics User Guide Integrity Objects Project Suite 9/7/2011 2:56:00 PM Copyright 2008 Alfadata Technologies Corporation. All Rights Reserved. Page

More information

Electrodes, Cells, Sensors & Accessories Superior sensors. Precise results.

Electrodes, Cells, Sensors & Accessories Superior sensors. Precise results. Electrodes, Cells, Sensors & Accessories Superior sensors. Precise results. Superior Sensors Precise Results Electrochemical analysis is one of the most frequent and demanding tasks in daily lab routines.

More information

Electrodes, Cells, Sensors & Accessories Superior sensors. Precise results.

Electrodes, Cells, Sensors & Accessories Superior sensors. Precise results. Electrodes, Cells, Sensors & Accessories Superior sensors. Precise results. Superior Sensors Precise Results Electrochemical analysis is one of the most frequent and demanding tasks in daily lab routines.

More information

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves Direct solenoid and solenoid pilot operated valves Series 59 Individual mounting Series inline 35 100 Ext. pilot port Accumulator EXH. Pilot valve Function plate From accumulator Pilot exhaust To accumulator

More information

Taylor Valve Technology, Inc

Taylor Valve Technology, Inc MULTI-ORIFICE VALVE MD SERIES PRODUCTION CHOKES Gas Lift Water Injection Enhanced Oil Recovery Throttling Valve High DP Valve Motor Operated Valve Manual and Automated Applications JUL0-TVT-OKC SERIES

More information

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves Direct solenoid and solenoid pilot operated valves Series 55 Individual mounting Series inline 35 Sealed solenoid enclosure Manual operator 100 200 Ext. pilot port Ext. pilot Pilot filter Pilot exh. 55

More information

Nutrient Profile Dalex Livestock Solutions All values except moisture are reported on a dry matter basis.

Nutrient Profile Dalex Livestock Solutions All values except moisture are reported on a dry matter basis. INGREDIENT NUTRIENT ANALYSIS 1 Dry Matter % 95.000 2 Protein % 3 RUP (%CP). - 4 RDP (%CP). - 100.000 5 SOL (%CP). - 211 NPN %SOL (%CP) 6.1-6 NPN % 7 ME CNCPS Mcal/lb 79 NEL Level 1 Mcal/lb 8 NEL CNCPS

More information

Report on Forensic Science Application

Report on Forensic Science Application Report on Forensic Science Application Assignment #4 Vikramaditya Jakkula [10917554] Introduction The goal of the assignment is to develop an ANN system which could classify a piece of glass from a beer

More information

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves Direct solenoid and solenoid pilot operated valves Series 57 Individual mounting Series inline 35 To accumulator Sealed solenoid enclosure 100 200 Ext. pilot port Pilot valve Function plate From accumulator

More information

ELECTROCHEMISTRY. BOECO ELECTRODES The electrodes are not included with the ph meters and have to be ordered separately:

ELECTROCHEMISTRY. BOECO ELECTRODES The electrodes are not included with the ph meters and have to be ordered separately: BOECO PORTABLE PH/ORP/TEMP METER MODEL PT-380 A Simultaneous displays ph or mv and temperature. A Convenient calibration with automatic buffer recognition of European and US buffer sets. Calibration data

More information

ANALYTICAL REPORT. Town of Stettler Box 280 Stettler, AB T0C 2L0. Grant McQuay. Client: Attention:

ANALYTICAL REPORT. Town of Stettler Box 280 Stettler, AB T0C 2L0. Grant McQuay. Client: Attention: ANALYTICAL REPORT Client: Town of Stettler Box 280 Stettler, AB T0C 2L0 KaizenLAB JOB #: DATE RECEIVED: 07-Jul-2016 179357 Attention: Grant McQuay DATE REPORTED: PROJECT ID: 13-Jul-2016 LOCATION: Routine

More information

Page : 1 of 40. FIELD OF TESTING : Calibration and Measurement CALIBRATION & MEASUREMENT CAPABILITY (CMC*)

Page : 1 of 40. FIELD OF TESTING : Calibration and Measurement CALIBRATION & MEASUREMENT CAPABILITY (CMC*) Caltek Pte Ltd Certificate No. : LA-2003-0292-C 23 Tagore Lane #04-08/09/10/11 Issue No. : 15 Tagore 23 Warehouse Singapore 787601 Date : 15 November 2017 FIELD OF TESTING : Calibration and Measurement

More information

Activity concentration for exempt material (Bq/g)

Activity concentration for exempt material (Bq/g) 173.436 Exempt material activity concentrations and exempt consignment activity limits for radionuclides. The Table of Exempt material activity concentrations and exempt consignment activity limits for

More information

Level and temperature switch Nivotemp NT-M, NT-MD

Level and temperature switch Nivotemp NT-M, NT-MD Level and temperature switch Nivotemp NT-M, NT-MD Fluidcontrol In hydraulics and lubrication technology the fill level of oil tanks needs to be monitored. Here, modern factory automation requires compatible

More information

ISO INTERNATIONAL STANDARD. Soil quality Determination of ph. Qualité du sol Détermination du ph. Second edition

ISO INTERNATIONAL STANDARD. Soil quality Determination of ph. Qualité du sol Détermination du ph. Second edition INTERNATIONAL STANDARD ISO 10390 Second edition 2005-02-15 Soil quality Determination of ph Qualité du sol Détermination du ph Reference number ISO 10390:2005(E) ISO 2005 ISO 10390:2005(E) PDF disclaimer

More information

Features: Quality Testing and Documentation

Features: Quality Testing and Documentation 1 The Yokogawa Falcon Series Dual Chamber Orifice Assembly YFOM-DC, is suitably designed for on-line retraction and inspection of orifice plates in process full flow and pressure conditions. The orifice

More information

Installation and Operating Instructions for Air-Bubbler Differential Pressure Aquagauge Tank Level Telemetry System.

Installation and Operating Instructions for Air-Bubbler Differential Pressure Aquagauge Tank Level Telemetry System. Installation and Operating Instructions for Air-Bubbler Differential Pressure Aquagauge Tank Level Telemetry System. Liquid depth is measured using a pressure sensor at the top of a column of air extending

More information

200 Series Meters Model 250, 225, 220, 215

200 Series Meters Model 250, 225, 220, 215 Electrochemistry 200 Series Meters Model 250, 225, 220, 215 Advanced features are standard on all Denver Instrument 200 Series Meters. Complete GLP/GMP/ISO documentation. All calibration points are time

More information

In-house based 1on OIML- R kg to 20 kg 10 kg to 20 kg

In-house based 1on OIML- R kg to 20 kg 10 kg to 20 kg MASS BALANCE: Mechanical, Electronic VOLUME DENSITY Condition: On-site charge equipment 500.- but minimum charge 1000.- Analytical balance 0 mg to 200 g readability 0.0001 g 1 mg to 200 g CSIRO 3,000.-

More information

Assembly and Maintenance

Assembly and Maintenance Assembly and Maintenance Assembly and Maintenance Test Pumps Pressure Test Pumps Tests all types of installations such as heating, compressed air and refrigeration systems, oil installations, fire lines

More information

Pipeline engineer competency standards list: onshore sector

Pipeline engineer competency standards list: onshore sector Pipeline engineer competency standards list: onshore sector ID Competency area/competency Gen Des Cons Ops Level General engineering GE001 Engineering degree in a relevant discipline x Core GE002 Pipeline

More information

OVAL FLOWMETER Meter Size: 34,65

OVAL FLOWMETER Meter Size: 34,65 OVAL FLOWMETER Meter Size:, ( Single Case Construction ) with Powerful Magnetic Coupling GENERAL SPECIFICATION GS.No.GBB8--E GENERAL The OVAL flowmeter is a positive displacement type flowmeter comprising

More information

DVM HPHT ULTRA HIGH ACCURACY SIMULTANEOUS DENSITY AND VISCOSITY MEASUREMENT

DVM HPHT ULTRA HIGH ACCURACY SIMULTANEOUS DENSITY AND VISCOSITY MEASUREMENT Single instrument for both measurement to extremely high accuracy Measure reservoir fluid at 30,000 psi and 400 F Less than 0.7 cc fluid sample required for measurement No hardware or software changes

More information

4 AA nickel-etal bybrid cells (min. 2,200 mah) Use only AC Adapter (5 VDC / min. 1 A) supplied for recharging

4 AA nickel-etal bybrid cells (min. 2,200 mah) Use only AC Adapter (5 VDC / min. 1 A) supplied for recharging METERS Microx 4 The Microx 4 is a completely stand-alone, portable fiber optic oxygen meter. It can be used with non-invasive sensors & probes (1 mm fiber), and oxygen microsensors (200 µm fiber) in different

More information

Creating an Environmental Database to Facilitate Groundwater Contamination Analysis. Jimmy Bowden Daniel B. Stephens and Associates

Creating an Environmental Database to Facilitate Groundwater Contamination Analysis. Jimmy Bowden Daniel B. Stephens and Associates Creating an Environmental Database to Facilitate Groundwater Contamination Analysis Jimmy Bowden Daniel B. Stephens and Associates Abstract Assigning responsibility for the cleanup of groundwater contamination

More information

JCT Series. Coolant-Through Holders for Small Parts Machining. Excellent Chip Control and Long Tool Life with High Pressure Coolant

JCT Series. Coolant-Through Holders for Small Parts Machining. Excellent Chip Control and Long Tool Life with High Pressure Coolant JC Series Coolant-hrough Holders for Small Parts Machining Excellent Chip Control and Long ool Life with High Pressure Coolant Capable of Pressure up to 2,900 psi Large Holder Lineup for urning, External

More information

Vacuum Meter Instruction Manual

Vacuum Meter Instruction Manual Vacuum Meter 840064 Instruction Manual TABLE OF CONTENTS 1. INTRODUCTION...2 2. METER DESCRIPTION...3 3. OPERATING INSTRUCTIONS 3-A PRECAUTIONS - READ BEFORE FIRST USE...4 3-B MEASUREMENT PROCEDURE...4

More information

LM903 Fluid Level Detector

LM903 Fluid Level Detector LM903 Fluid Level Detector General Description The LM903 uses the thermal-resistive probe technique to measure the level of nonflammable fluids A low fluid level is indicated by a warning lamp operating

More information

Electromechanical pressure switches

Electromechanical pressure switches Presentation Electromechanical pressure switches For control circuits, types ACW and ADW Presentation Pressure switches type ACW and ADW are switches for control circuits, with an adjustable differential.

More information

SFC KOENIG Product Catalog

SFC KOENIG Product Catalog SFC KOENIG Product Catalog 8 2016 SFC KOENIG I www.sfckoenig.com The World s Leading Sealing & Flow Control Technology With over 3 billion parts installed and failure rates less than 1 part per million,

More information

Drillingsoftware Casing Design User Manual

Drillingsoftware Casing Design User Manual Drillingsoftware Casing Design User Manual 1. Introduction Working Stress Design (WSD) loads are evaluated throughout the entire length of the casing from the Well Head to the Casing Shoe. True Vertical

More information

FS1023 Datasheet. Liquid Flow Sensor Module. Description. Features. FS1023 Flow Sensor Module. Typical Applications

FS1023 Datasheet. Liquid Flow Sensor Module. Description. Features. FS1023 Flow Sensor Module. Typical Applications Liquid Flow Sensor Module FS1023 Datasheet Description The FS1023 MEMS Liquid Flow Sensor Module measures the flow rate using the thermo-transfer (calorimetric) principle. The FS1023 is designed to measure

More information

Appendix Introduction

Appendix Introduction Appendix Introduction This section describes features of the OLI Studio. The chapter starts with an overview of the OLI Studio Interface, including some calculation objects discussed previously. A.1 Creating

More information

98 Series Back Pressure. Valve Link. Features. Fisher Controls. August 1993 Bulletin 71.4:98

98 Series Back Pressure. Valve Link. Features. Fisher Controls. August 1993 Bulletin 71.4:98 Series Back Pressure and Type Relief VL000 Valves FIELDVUE Valve Link Fisher Controls August Bulletin.: The Series (figure ) is used for back pressure or relief applications in liquid, gas, air, and steam

More information

Figure 2: Water Into Kerosene, Volume Fraction (Left) And Total Density Of Mixture (Right)

Figure 2: Water Into Kerosene, Volume Fraction (Left) And Total Density Of Mixture (Right) Jared Bottlinger MAE598 Project 3 11/16/17 Task 1 a) Figure 1: Volume Fraction Of Water At 0.4s Task 1 b) Figure 2: Water Into Kerosene, Volume Fraction (Left) And Total Density Of Mixture (Right) Task

More information

8-CHANNEL, WET-MATE, OPTICAL CONNECTOR

8-CHANNEL, WET-MATE, OPTICAL CONNECTOR molar`q a^q^pebbq 8-CHANNEL, WET-MATE, OPTICAL CONNECTOR, bulkhead mounted plug (left), flying lead ROV receptacle (right) DESCRIPTION The is a field proven, second generation underwater mateable, high

More information

Z-15GW2277 Z-15GW2277-B

Z-15GW2277 Z-15GW2277-B Basic Switch GENERAL PURPOSE General Purpose Basic Switch High precision basic switch in a variety of styles Wide margins of operating conditions increase the operating speed range Available in general

More information

Variable Area Flowmeter DATASHEET

Variable Area Flowmeter DATASHEET Variable Area Flowmeter DATASHEET JUNHO 0 Data sheet DS/A6/6EN Rev. I Models A600 & A600 Purgemaster SNAP-IN Small Flowmeter Long-term reliable performance flowmeters with low cost-of-ownership High strength

More information

FILTER NAME CONSTRUCTION FEATURES APPLICATIONS ORDER CODE MEMBRANE Body: polycarbonate Filter: PTFE membrane

FILTER NAME CONSTRUCTION FEATURES APPLICATIONS ORDER CODE MEMBRANE Body: polycarbonate Filter: PTFE membrane Filter Caps for Humidity and Dewpoint Transmitters with probe 12 mm (0.47 ) The right choice of appropriate filter cap is essential for best long term performance in the application. For assistance please

More information

Benchtop Multi-parameter Water Quality Meter

Benchtop Multi-parameter Water Quality Meter LMPWM-A Series Benchtop multi-parameter water quality meter LMPWM-A series is comes with different measurement modes for quality and testing of water on different parameters. It measures ph, Conductivity,

More information

Choke Valves SINCE1958. Unique. Precise. Quality. Reliable.

Choke Valves SINCE1958. Unique. Precise. Quality. Reliable. SINCE95 MC SERIES Choke Valves Unique. Precise. Quality. Reliable. MOV Valve Principle of Operation Taylor Valve Technology Multi-Orifice Valve Design Principle Provides Precision Control. The two adjacent

More information

Industrial Parts Catalog 2015

Industrial Parts Catalog 2015 P a g e 1 Industrial Parts Catalog 2015 Call now for your discount rate! If we don t stock it, we can get it! Provide the part number, manufacturer, picture and we will do the rest P a g e 2 Table of Contents

More information

JUMO PINOS L01. Calorimetric flow sensor. Brief description. Special features. Customer benefits. Data Sheet

JUMO PINOS L01. Calorimetric flow sensor. Brief description. Special features. Customer benefits. Data Sheet sales@jumo.co.uk info.us@jumo.net Page 1/9 JUMO PINOS L01 Calorimetric flow sensor Brief description The JUMO PINOS L01 flow sensor serves the measuring and monitoring of flow velocities of water and aqueous

More information

Furnace Camera System Operator s Manual. Version

Furnace Camera System Operator s Manual. Version Furnace Camera System Operator s Manual Version 12-2010 Contents 1. Introduction... 2 2. Description... 2 2.1 Model Nomenclature... 2 2.2 Specifications... 3 2.3 Confirmation of Camera Field of View...

More information

Universal Compact Extruded Cylinders

Universal Compact Extruded Cylinders Universal Compact Extruded Cylinders Clippard s new Compact, Extruded Body Cylinders are available in double acting, double rod, single acting spring return, and single acting spring extended models. Universally

More information

ProfiLine Handhelds. For ph, ISE, Dissolved Oxygen and Conductivity

ProfiLine Handhelds. For ph, ISE, Dissolved Oxygen and Conductivity ProfiLine Handhelds For ph, ISE, Dissolved Oxygen and Conductivity ProfiLine Single Parameter Instruments Data-logging Ground Water Wastewater Surface waters Quality Fishfarming 3110 Series and 3205 :

More information

3/2 5/2 SERIES 362/562

3/2 5/2 SERIES 362/562 Manual and Pilot Operated Spool Valves 6L Stainless Steel and Brass Bodies /4" to " NPT / / 6/6 Features Ideal for valve automation for the oil and gas market Reliable, robust design with high flow performance

More information

Indicating Digital Transmitter for Differential Pressure and Flow. Media 6 with LCD Media 6 with LED

Indicating Digital Transmitter for Differential Pressure and Flow. Media 6 with LCD Media 6 with LED Indicating Digital Transmitter for Differential Pressure and Flow Media 6 with LCD Media 6 with LED Application Microprocessor-controlled transmitter for measuring and indicating the differential pressure

More information

Rosemount 1595 Conditioning Orifice Plate

Rosemount 1595 Conditioning Orifice Plate Reference Manual Rosemount 1595 Conditioning Orifice Plate www.rosemount.com Reference Manual 00809-0100-4828, Rev BA Rosemount 1595 Rosemount 1595 Conditioning Orifice Plate NOTICE Read this manual before

More information

B Signs and Symbols. Language Usage. RIT Score Range: RIT Score Range: RIT Score Range: RIT Score Range:

B Signs and Symbols. Language Usage. RIT Score Range: RIT Score Range: RIT Score Range: RIT Score Range: B Signs and Symbols Appendix B contains NWEA s assessment signs and symbols for the subjects of language usage, mathematics, science concepts and processes, and general science. Within each subject area

More information

The DDM 2909 Automatic Density Meter

The DDM 2909 Automatic Density Meter TECHNICAL BULLETIN 935 For the Most Demanding cglp/gmp Laboratories The DDM 2909 Automatic Density Meter Densitometry Applications The DDM 2909 Density Meter, with high precision Peltier temperature control

More information

Technical Procedure for Inductively Coupled Plasma Mass Spectrometry (ICP-MS) for Gunshot Residue Analysis

Technical Procedure for Inductively Coupled Plasma Mass Spectrometry (ICP-MS) for Gunshot Residue Analysis Technical Procedure for Inductively Coupled Plasma Mass Spectrometry (ICP-MS) for Gunshot Residue Analysis 1.0 Purpose This technical procedure shall be followed for the operation of the Inductively Coupled

More information

Africa Soil Information for taking agronomy to scale

Africa Soil Information for taking agronomy to scale Africa Soil Information for taking agronomy to scale results Johan Leenaars (September 23 rd, 2015) ISRIC brief (e.g. AfSIS) (e.g. GYGA) Africa Soil Information Need for Complete, coherent, detailed, properties,

More information

Electronic Oil Meter OM 20

Electronic Oil Meter OM 20 INSTRUCTION MANUAL S1710, Rev A Electronic Oil Meter OM 20 Congratulations on purchase of this World Class Electronic Oil Meter! Electronic digital meter featuring an oval-gear measurement system. Designed

More information

Assembly. 1 Compact version with valve plug 2 Short tube version with cable 3 Compact version with M12 plug 4 Short tube version with M12 plug

Assembly. 1 Compact version with valve plug 2 Short tube version with cable 3 Compact version with M12 plug 4 Short tube version with M12 plug Vibration Limit Switch Features Limit switch for liquids External function test with test magnet Onsite function check possible thanks to LED indication Large selection of process connections for hassle-free

More information

Level Plus. Liquid-Level Sensors With Temposonics Technology. Accessories Catalog

Level Plus. Liquid-Level Sensors With Temposonics Technology. Accessories Catalog Features Level Plus Liquid-Level Sensors With Temposonics Technology Floats, s and Accessories for Process Level and Tank Gauging Applications Accessories Catalog Variety of styles and sizes to fit most

More information

Tutorial EN

Tutorial EN Tutorial 8.102.8001EN Metrohm AG CH-9101 Herisau Switzerland Phone +41 71 353 85 85 Fax +41 71 353 89 01 info@metrohm.com www.metrohm.com Tutorial 8.102.8001EN 07.2009 ek Teachware Metrohm AG CH-9101

More information

The Vernier Adapter DATA HARVEST. (Product No. 3051)

The Vernier Adapter DATA HARVEST. (Product No. 3051) Smart The Vernier Adapter (Product No. 3051) DATA HARVEST Data Harvest Group Ltd. 1 Eden Court, Leighton Buzzard, Beds, LU7 4FY Tel: 01525 373666 Fax: 01525 851638 e-mail: sales@data-harvest.co.uk www.data-harvest.co.uk

More information

Highly Successful Reservoir Surveillance and Production Enhancement in a North Sea Brown Field Asset

Highly Successful Reservoir Surveillance and Production Enhancement in a North Sea Brown Field Asset Highly Successful Reservoir Surveillance and Production Enhancement in a North Sea Brown Field Asset Thistle Field Summary Thistle Field Northern North Sea oil field. Brent Group reservoir. First production

More information

D2SW-3L1HS D2SW-01L1HS

D2SW-3L1HS D2SW-01L1HS Sealed Snap Action Switch D2SW Watertight Miniature Snap Action Switch High-quality watertight miniature Snap Action switch. Switch Body meets IP67 (IEC 529) requirements Monoblock construction assures

More information

Table of Contents. Chapter 1 Introduction General Information... 1 Meter Packing List... 2

Table of Contents. Chapter 1 Introduction General Information... 1 Meter Packing List... 2 Table of Contents Chapter 1 Introduction General Information.................................................. 1 Meter Packing List................................................... 2 Chapter 2 Meter

More information

Proximity Sensor Ideal for High Temperatures and Cleaning Processes. Applicable to 120 C

Proximity Sensor Ideal for High Temperatures and Cleaning Processes. Applicable to 120 C Proximity Ideal for High Temperatures and Cleaning Processes EEH CSM_EEH_DS_E Proximity Ideal for the Food and Beverage Industry SUS6L Body, IP69K Protection, Resistant to High Temperatures and Detergents

More information

Refraction of Light. c = m / s. n = c v. The index of refraction is never less than 1. Some common indices of refraction are listed below.

Refraction of Light. c = m / s. n = c v. The index of refraction is never less than 1. Some common indices of refraction are listed below. Refraction of Light The speed of light in a vacuum is c = 3.00 10 8 m / s In air, the speed is only slightly less. In other transparent materials, such as glass and water, the speed is always less than

More information

Optimization of under-relaxation factors. and Courant numbers for the simulation of. sloshing in the oil pan of an automobile

Optimization of under-relaxation factors. and Courant numbers for the simulation of. sloshing in the oil pan of an automobile Optimization of under-relaxation factors and Courant numbers for the simulation of sloshing in the oil pan of an automobile Swathi Satish*, Mani Prithiviraj and Sridhar Hari⁰ *National Institute of Technology,

More information

Office of Oil and Gas Management Oil and Gas Reporting Electronic Unconventional Well Monthly Production Reporting Guide

Office of Oil and Gas Management Oil and Gas Reporting Electronic Unconventional Well Monthly Production Reporting Guide Office of Oil and Gas Management Oil and Gas Reporting Electronic Unconventional Well Monthly May 16, 2018 Version 1.2 Table of Contents Purpose... 2 Applications Support Help Desk Team... 2 Introduction...

More information

TANK CARE. Return Filters RD MATERIALS. Cover & housing: Anodized aluminium alloy. Bypass valve: Polyammide

TANK CARE. Return Filters RD MATERIALS. Cover & housing: Anodized aluminium alloy. Bypass valve: Polyammide TAK CARE Return ilters R MATERIAL Cover & housing: Anodized aluminium alloy ypass valve: Polyammide CLOGGIG IICATOR A differential visual or electrical indicator allows monitoring of the element condition,

More information

B64G - Olympian Plus plug-in system Filter/regulator

B64G - Olympian Plus plug-in system Filter/regulator BG - Olympian Plus plug-in system > > Port size: /... / (ISO G/PTF) > > High efficiency water removal > > Diaphragm and balanced valve design ensure good regulation characteristics > > on-rising adjusting

More information

HI 9828 Multiparameter Water Quality Meter...

HI 9828 Multiparameter Water Quality Meter... HI 9828 Multiparameter Water Quality Meter... Backlit LCD can display up to 12 Measurements at a time Feature Highlights Display up to 12 parameters Graphic LCD with backlight Meter features IP67 and probe

More information

NOTE: Reducing flanges are available in all types and pressures.

NOTE: Reducing flanges are available in all types and pressures. Flanges Types : Weld Flanges, Slip-On Flanges, Weld Flanges, Threaded Flanges, Flanges, Blind Flanges. 1/2" - 24" Class 150, 300, 400, 600, 900, 1500 and 2500 NOTE: Reducing flanges are available in all

More information

Float switch 298. Use. Variants. + Sturdy construction with very few moving parts. + Standard flange with different hole patterns

Float switch 298. Use. Variants. + Sturdy construction with very few moving parts. + Standard flange with different hole patterns Float switch 298 + Sturdy construction with very few moving parts + Standard flange with different hole patterns + Operating temperature -40 C to +85 C + Long lifetime due to wear-free reed contacts +

More information

Multipole and Fieldbus

Multipole and Fieldbus > Series 3 Plug-In valve islands Valve Islands > 016 Series 3 Plug-In valve islands, Multipole and Fieldbus New versions Plug-In system for Series 3 solenoid valves, G1/8 port. Valve functions: x3/, 5/

More information

Spare parts list. Handheld pneumatic pick hammers CP 0222 CHIT, CP 0222 CHIT BS, CP 0222 CHOT BS.

Spare parts list. Handheld pneumatic pick hammers CP 0222 CHIT, CP 0222 CHIT BS, CP 0222 CHOT BS. Spare parts list Handheld pneumatic pick hammers CP 0 CHIT, CP 0 CHIT, CP 0 CHOT www.cp.com CP 0 CHIT, CP 0 CHIT, CP 0 CHOT 9800 00 0 CP 0 CHIT, CP 0 CHIT, CP 0 CHOT Contents Contents General information...............................................................

More information

38 SERIES JUMBO MODULAR

38 SERIES JUMBO MODULAR 8 SERIES JUMBO MODULAR A I R P R E P A R A T I O N S Y S T E M CORPORATION Filter The F8 jumbo filter includes a standard -micron element, quick-disconnect integral plastic bowl with bowl guard, and manual

More information

8-CHANNEL, WET-MATE, OPTICAL CONNECTOR

8-CHANNEL, WET-MATE, OPTICAL CONNECTOR molar`q a^q^pebbq 8-CHANNEL, WET-MATE, OPTICAL CONNECTOR, bulkhead mounted plug (left), flying lead ROV receptacle (right) DESCRIPTION The is a field proven, second generation underwater mateable, high

More information

I3 Consulting Clean rooms for Pharmaceuticals & Medical Device Manufacturing

I3 Consulting Clean rooms for Pharmaceuticals & Medical Device Manufacturing I3 Consulting Clean rooms for Pharmaceuticals & Medical Device Manufacturing Introduction to Clean Rooms A cleanroom is a controlled environment where Pharmaceuticals, APIs, Medical Devices, Food, Cosmetics,

More information

FLECK 5810 & 5812 XTR2 WATER SOFTENER OR FILTER CONTROL VALVE SERVICE MANUAL

FLECK 5810 & 5812 XTR2 WATER SOFTENER OR FILTER CONTROL VALVE SERVICE MANUAL FLECK 5810 & 5812 XTR2 WATER SOFTENER OR FILTER CONTROL VALVE SERVICE MANUAL 5810 5812 waterpurification.pentair.com TABLE OF CONTENTS OPERATING PARAMETERS... 2 INSTALLATION... 3 START-UP INSTRUCTIONS/FLUSHING

More information

Quick-connect terminals (#110)

Quick-connect terminals (#110) Sealed Subminiature Basic Switch D2SW-P Sealed Basic Switch with Simplified Construction, Mounting Compatible with SS and D2SW Series. Sealed to IEC IP67. Switch rating of 2 at 250 VC possible with a single-leaf

More information

QuickChange NX Liquid Filters

QuickChange NX Liquid Filters MICROCONTMINTION CONTROL QuickChange NX Liquid Filters High-performance, yield-enabling particle protection for aqueous-based chemistries QuickChange NX nondewetting filters deliver a cost-effective solution

More information

RM/92000/M, Short stroke cylinder Magnetic piston, double acting

RM/92000/M, Short stroke cylinder Magnetic piston, double acting > Ø... 00 mm > One third the basic length of a corresponding ISO/VDM model > Fully non-corrodible specification > Standard magnetic piston for full control system versatility > Low friction, long life

More information

WPAN and PSO based Water Quality Monitoring with LabVIEW as data logger

WPAN and PSO based Water Quality Monitoring with LabVIEW as data logger WPAN and PSO based Water Quality Monitoring with LabVIEW as data logger Anita Gehlot #1, Rajesh Singh #2, Rohit Samkaria #3, Sushabhan Choudhury #4 # University of Petroleum and Energy Studies, Dehradun

More information

PLC 24 FERRIC CHLORIDE AND POLYMER SYSTEM SCADA SYSTEM OPERATION MANUAL. Revision 1.0 May 3, 2006

PLC 24 FERRIC CHLORIDE AND POLYMER SYSTEM SCADA SYSTEM OPERATION MANUAL. Revision 1.0 May 3, 2006 PLC 24 FERRIC CHLORIDE AND POLYMER SYSTEM SCADA SYSTEM OPERATION MANUAL Revision 1.0 May 3, 2006 PLC 24 FERRIC CHLORIDE AND POLYMER SYSTEM SCADA SYSTEM OPERATION MANUAL Revision 1.0 May 3, 2006 Table of

More information

JCT Series. Coolant-Through Holders. Excellent Chip Control and Long Tool Life with High Pressure Coolant

JCT Series. Coolant-Through Holders. Excellent Chip Control and Long Tool Life with High Pressure Coolant JCT Series Coolant-Through Holders Excellent Chip Control and Long Tool Life with High Pressure Coolant Large Holder Lineup for Turning, External Grooving, Cut-off and Threading Easy Connection with High

More information

MANOMETER OPERATION MANUAL mbar, differential input. Model : PM-9107

MANOMETER OPERATION MANUAL mbar, differential input. Model : PM-9107 7000 mbar, differential input MANOMETER Model : PM-9107 Your purchase of this MANOMETER marks a step forward for you into the field of precision measurement. Although this MANOMETER is a complex and delicate

More information

User Manual. ExStik EC500. ph/conductivity / TDS / Salinity / Temperature Meter EC500. Additional User Manual Translations available at

User Manual. ExStik EC500. ph/conductivity / TDS / Salinity / Temperature Meter EC500. Additional User Manual Translations available at User Manual ExStik EC500 ph/conductivity / TDS / Salinity / Temperature Meter EC500 Additional User Manual Translations available at www.extech.com Introduction Congratulations on your purchase of the

More information

Level and temperature switch Nivotemp NT-M, NT-MD

Level and temperature switch Nivotemp NT-M, NT-MD Level and temperature switch Nivotemp NT-M, NT-MD Fluidcontrol In hydraulics and lubrication technology the fill level of oil tanks needs to be monitored. Here, modern factory automation requires compatible

More information

Houston Digital Instruments, Inc. Product Catalog

Houston Digital Instruments, Inc. Product Catalog Houston Digital Instruments, Inc. Product Catalog 2000B-Low Cost 2400-Custom Options 3300-Temperature 2100-Stroke Counter (1-4) 2200-Position Indicator 2000P-Parking Meter Issue date: September 29, 2003

More information

Modbus Signal Output Adapter Quick Start Guide

Modbus Signal Output Adapter Quick Start Guide TM Modbus Signal Output Adapter Quick Start Guide Adapter Overview: Mini USB Connector Used to configure adapter settings, provide power to the adapter, and passthrough communication to the attached sonde.

More information

The DDM 2911 Automatic Density Meter

The DDM 2911 Automatic Density Meter TECHNICAL BULLETIN 922 United States Department of Commerce National Institute of Standards and Technology For the Most Demanding cglp/gmp Laboratories The DDM 2911 Automatic Meter NVLAP LAB CODE: 200898-0

More information

RMI and RMP multi-couplings for fast tool change on injection molding and die cast equipment

RMI and RMP multi-couplings for fast tool change on injection molding and die cast equipment RMI-RMP L100.05 us B RMI and RMP multi-couplings for fast tool change on injection molding and die cast equipment STÄUBLI CORPORTION P.O. BOX 189 - DUNCN - S.C. 29334 PHONE 864/433-1980 TOLL-FREE NUMBER

More information

Taylor Valve Technology, Inc

Taylor Valve Technology, Inc MULTI-ORIFICE VALVE Taylor Valve MD SERIES PRODUCTION CHOKES Gas Lift Water Injection Enhanced Oil Recovery Throttling Valve High DP Valve Motor Operated Valve Manual and Automated Applications JAN00-TVT-OKC

More information