SLOT DIFFUSERS ALS SERIES SLOT DIFFUSER ALS37. The Airvector exclusive UNIFLEX pattern and volume controller Deflector-damper
|
|
- Holly French
- 6 years ago
- Views:
Transcription
1 SLO DIFFUSERS ALS SERIES SLO DIFFUSER For, and Installation Series ALS Architectural Linear Slot Diffusers are designed for installation in the ceiling, sidewall or sill and are recommended for supplying heated, ventilated or cooled air and for returning or exhausting room air. Air pattern directional changes through are effected by the integral "Uniflex" combination pattern and volume controller, permitting pattern adjustment to meet changing requirements. heir reliable performance assures confident use of cooling temperature differentials up to F at predicted low air motion FPM in the zone of occupancy. Series ALS Diffusers perform efficiently with air loadings of to CFM per square feet of floor area or to air changes per hour (based on ft. ceiling height) at a sound level range of to. When installed in the ceiling, Series ALS Diffusers provide a horizontal air path that is adjustable through in each slot opening. One to ten slot ALS Diffusers can be adjusted to provide oneway or twoway air patterns by directing the controller as required to either side. Vertical downward air pattern can be adjusted from all slots. A combination horizontal pattern and vertical down pattern can be effected from a two (or more) slot diffuser. Series ALS diffusers are fabricated of highquality aluminum extrusions. he pattern controller is coated dull black to accent the slot opening. Components are mechanically interlocked together for a blemishfree appearance. Keyways and splice plates facilitate sections over to form continuous lengths. Ninety degree mitered corner sections are furnished in one piece. ALS FEAURES HREE SLO SIZES, /", /" and ". ONE O EIGH slots wide for air volume of 0 CFM per foot. EXRUDED ALUMINUM construction: mechanical assembly. White powder paint finishstandard. OVERLAPPING OR BAR MARGINS. ACCESSORIES Mitered Corner Sections AVAILABLE BUS in continuous lengths with keyway splices. Factory cut or field cut lengths for precise installation. "UNIFLEX" ADJUSABLE PAERN AND VOLUME CONROLLER provides positive positioning, constant static pressure, constant outlet area. Concealed mounting brackets fit in a hemmed duct collar to positively hold the diffuser in ceiling and sidewall installations. Series ALS diffusers used for return or exhaust air are identical to supply sections except the pattern controller is removed to increase air capacity. Spacer Slide Air duct he Airvector exclusive UNIFLEX pattern and volume controller Deflectordamper Margin Rev.
2 ARCHIECURAL SYLES ALS SERIES SLO DIFFUSER HOW O ORDER ALS SERIES ALS E GK /W LISED SIZES AVAILABLE Any fractional inch increment of length " to " One to ten slots Lengths longer than " will be furnished in multiple sections for field butting. Custom Paint Lengths over 0" will be furnished in multiple sections SYLE DEAILS MARGIN ONLY MARGIN, DAMPER AND PAERN CONROLLER Return MODEL SERIES Slot Diffuser Slot Return / Slot Diffuser / Slot Return / Slot Diffuser / Slot Return MARGIN SYLE Bar LayIn ALS ALS ALS ALS ALS ALS E FASENING No Fastening Screw Fastening Concealed Mounting Frame Gasket LENGH (IHES) FINISH (OPIONAL) Standard is White (/W) See chart for more NUMBER OF SLOS GK Series ALS products include a /" tolerance for thermal expansion based on +0 degree F temperature differential. For every + degree F differential above +0 degree F, reduce required listed length by /" per feet of length. FASENING MEHOD No Fastening Screw Concealed DIMENSIONAL DAA LENGH Surface mounting Nominal + /" E B + /" Duct opening B Overall neck size N/A with Nominal /" bar mounting (N/A with ) /" SLO /" SLO " SLO."." X Y X Y X Y 0." Y X /" /" /" /" /" " W Overall width /" SLO /" SLO " SLO SLOS B /" /" /" /" /" /" /" /" W /" /" /" /" /" /" /" /" SLOS B /" /" /" /" /" " /" /" W /" /" /" /" /" /" /" /" SLOS B /" /" /" /" /" /" /" /" W /" /" /" /" /" /" /" /" Rev.
3 ENGINEERING PERFORMAE DAA ALS " SLO SUPPLY DIFFUSER ABLE SUPPLY AIR CFM per Foot in Direction of Min. P S In. H O Outlet Velocity () FPM hrow () in Feet Minimum Height in F V / / /' SILL ' V / / ' SIDEWALL V / ' / CEILING ONE WAY V CEILING WO WAY ' and slots not available Rev.
4 ENGINEERING PERFORMAE DAA ALS " SLO SUPPLY DIFFUSER NOES: a. able based on ft. diffuser length. For longer lengths, correct throw and per able. b. For way ceiling throw, proportion (CFM) and number of slots in each direction of and select from way data, able. c. When using continuous diffuser lengths with alternating active and inactive sections, a reduction in throw can be obtained by omitting the factors contained in able. d. P S constant for horizontal way, way and vertical pattern adjustment. e. air temperature effect on horizontal throw is shown in able. Vertical throw at varying supply air temperatures is shown in able. f. erminal velocities (V ) at the minimum and maximum hrow () positions are rated at FPM and 0 FPM respectively with corresponding room velocities ( ) of 0 FPM and FPM. ABLE CONINUOUS DIFFUSER LENGH FACORS ABLE SUPPLY AIR EMPERAURE FACORS Modify able by factors for diffuser lengths above ft. Diffuser Length ' ' ' ' ' 0' hrow () No Change x. x Multiply hrow in able (or factor in able if used) by listed F x.0 x. x. ABLE VERICAL DOWNHROW and emperature Factors. m (') MAX.. m (') MIN. Multiply hrow in able (or factor in able if used) by listed 0 + C Case Case Case + F Cooling Ventilating Heating x.0 x.0 x.0 x.0 x.0 x.0 Horizontal AIR MEASUREMEN Vertical Return Air ABLE SUPPLY DIFFUSERS AREAS Per Ft. of Length 00 VELOMEER JE FOR VELOCIY " A N Area A K constant for horizontal way, way and vertical pattern. CFM = A K x length in feet x Rev.
5 ENGINEERING PERFORMAE DAA ALS " SLO REURN ABLE REURN AIR CFM PER FOO OF LENGH A K Area Application NonDucted 0 " P S " P S.0" P S." P S." P S." P S CFM CFM CFM CFM CFM CFM Capacity based on diffuser without pattern controller. When pattern controller is used CFM capacities are reduced by % at listed P S, and A K. Rev.
6 ENGINEERING PERFORMAE DAA ALS /" SUPPLY SLO DIFFUSER ABLE SUPPLY AIR CFM per Foot in Direction of 0 Min. P S In. H O < Outlet Velocity () FPM hrow () in Feet Minimum Height in F / < < < < < < < /' SILL V ' / < V / < < SIDEWALL ' V / / ' CEILING ONE WAY < V ' / CEILING WO WAY and slots not available / Outlet Velocity () FPM otal Pressure (P ) Inches H O SYMBOLS V erminal Velocity in FPM Room Velocity in FPM Outlet Velocity in FPM A K Outlet area in Sq. Feet A N Neck Area in Sq. Ft. P S Static Pressure H O Re db Room attenuation hrow in feet at X and Y emperature Differential Rev.
7 ENGINEERING PERFORMAE DAA ALS /" SLO SUPPLY DIFFUSER NOES: a. able based on ft. diffuser length. For longer lengths, correct throw and per able. b. For way ceiling throw, proportion (CFM) and number of slots in each direction of and select from way data, able. c. When using continuous diffuser lengths with alternating active and inactive sections, a reduction in throw can be obtained by omitting the factors contained in able. d. P S constant for horizontal way, way and vertical pattern adjustment. e. air temperature effect on horizontal throw is shown in able. Vertical throw at varying supply air temperatures is shown in able. f. erminal velocities (V ) at the minimum and maximum hrow () positions are rated at FPM and 0 FPM respectively with corresponding room velocities ( ) of 0 fpm and FPM. ABLE CONINUOUS DIFFUSER LENGH FACORS ABLE SUPPLY AIR EMPERAURE FACORS Modify able by factors for diffuser lengths above ft. Diffuser Length ' ' ' ' ' 0' hrow () No Change x. x Multiply hrow in able (or factor in able if used) by listed 0 x.0 x. x. ABLE VERICAL DOWNHROW and emperature Factors. m (') MAX.. m (') MIN. Multiply hrow in able (or factor in able if used) by listed 0 C Case Case Cooling Ventilating Heating x.0 x.0 x.0 Horizontal AIR MEASUREMEN Vertical Return Air Case x.0 x.0 x.0 ABLE SUPPLY DIFFUSERS AREAS Per Ft. of Length 00 VELOMEER JE FOR VELOCIY " A N Area A K Area A K constant for horizontal way, way and vertical pattern. CFM = A K x length in feet x Rev.
8 ENGINEERING PERFORMAE DAA ALS /" SLO REURN ABLE REURN AIR CFM Per Foot of Length A K Area Application NonDucted 0 " P S " P S.0" P S." P S." P S." P S CFM CFM CFM CFM CFM CFM Capacity based on diffuser without pattern controller. When pattern controller is used CFM capacities are reduced by % at listed P S, and A K. Rev.
9 ENGINEERING PERFORMAE DAA ALS /" SUPPLY SLO DIFFUSER ABLE SUPPLY AIR CFM per Foot in Direction of Min. P S In. H O.0 Outlet Velocity () FPM hrow () in Feet Minimum Height in F / <.0 < < V 0.0 < < < /' SILL ' 0.0 <.0 00 / < < V / < ' < / / < < < < SIDEWALL V < < < CEILING ONE WAY ' / / < < CEILING WO WAY V ' < < < Outlet Velocity () FPM otal Pressure (P ) Inches H O SYMBOLS V erminal Velocity in FPM Room Velocity in FPM Outlet Velocity in FPM A K Outlet area in Sq. Feet A N Neck Area in Sq. Ft. P S Static Pressure H O Re db Room attenuation hrow in feet at X and Y emperature Differential Rev. and slots not available
10 ENGINEERING PERFORMAE DAA ALS /" SLO SUPPLY DIFFUSER NOES: a. able based on ft. diffuser length. For longer lengths, correct throw and per able. b. For way ceiling throw, proportion (CFM) and number of slots in each direction of and select from way data, able. c. When using continuous diffuser lengths with alternating active and inactive sections, a reduction in throw can be obtained by omitting the factors contained in able. d. P S constant for horizontal way, way and vertical pattern adjustment. e. air temperature effect on horizontal throw is shown in able. Vertical throw at varying supply air temperatures is shown in able. f. erminal velocities (V ) at the minimum and maximum hrow () positions are rated at FPM and 0 FPM respectively with corresponding room velocities ( ) of 0 fpm and FPM. ABLE CONINUOUS DIFFUSER LENGH FACORS ABLE SUPPLY AIR EMPERAURE FACORS Modify able by factors for diffuser lengths above ft. Diffuser Length ' ' ' ' ' 0' hrow () No Change x. x Multiply hrow in able (or factor in able if used) by listed 0 x.0 x. x. ABLE VERICAL DOWNHROW and emperature Factors. m (') MAX.. m (') MIN. Multiply hrow in able (or factor in able if used) by listed 0 C Case Case Cooling Ventilating Heating x.0 x.0 x.0 Horizontal AIR MEASUREMEN Vertical Return Air Case x.0 x.0 x.0 ABLE SUPPLY DIFFUSERS AREAS Per Ft. of Length 00 VELOMEER JE FOR VELOCIY " A N Area A K Area A K constant for horizontal way, way and vertical pattern. CFM = A K x length in feet x Rev.
11 ENGINEERING PERFORMAE DAA ALS /" SLO REURN ABLE REURN AIR CFM Per Foot of Length A K Area Application NonDucted 0 " P S " P S.0" P S." P S." P S." P S CFM CFM CFM CFM CFM CFM Capacity based on diffuser without pattern controller. When pattern controller is used CFM capacities are reduced by % at listed P S, and A K. HOW O SPECIFY ARCHIECURAL LINEAR SLO DIFFUSERS Diffuser and mounting of linear slot diffuser with uniflex pattern and volume controller, series ALS. Constructed from powder coater extruded aluminum with degree mitered corners, manufactured by Airvector. Return and mounting of linear slot return, series ALS. Constructed from powder coater extruded aluminum with degree mitered corners, manufactured by Airvector. Rev.
PERFORMANCE DATA SCD. SCD 12 in. x 12 in. Face Size. SCD 20 in. x 20 in. Face Size. Square Cone Diffuser
12 in. x 12 in. Face 4 Neck Velocity (fpm) 400 00 00 00 00 900 00 1200 1400 0 Velocity Pressure (in. w.g.)..01.022.031.040.00.02.090.122..013.021.030.041.04.0.04.121.1.21 Flow Rate (cfm) 3 44 2 1 0 4 122
More informationDRI. VARIZON Displacement unit with adjustable spread pattern
VARIZON Displacement unit with adjustable spread pattern Quick facts Adjustable spread pattern and affected area Suitable for all types of rooms Cleanable Air volume measuring point Very simple to install
More informationSlot diffusers, Round duct diffusers IMP Klima 04 Slot diffusers Round duct diffusers 176
B 0 LD- F 9. φ D H H a 8.5 5 5 A E 7 LD- F 8 8.5 9. 5 5 A 7 E LD-/ LD-/ LD- O/ LD- O/ LD- O/ LD- O/.5.5.5.5 LD-/ LD-/ LD-/ LD-/ LD-/ LD-/ 7.5 7.5 07 LD- O/ LD- O/ LD- O/ LD- O/ 5.5 5.5 5.5 5.5 9.5 87.5
More informationAdjustable swirl diffuser PDZA TECHNICAL DATA
Adjustable swirl diffuser PDZA TECHNICAL DATA Adjustable swirl diffuser PDZA Adjustable ceiling swirl diffuser PDZA is intended for commercial and industrial buildings with a large room volume and high
More informationFloormaster DVQA, quarter-cylindrical terminals
Floormaster DVQA are quarter-cylindrical supply air terminals for positioning on the floor in a corner. The terminals are designed for displacement air handling in accordance with the Floormaster system
More informationGTH. Rectangular double deflection grille QUICK FACTS
Rectangular double deflection grille QUICK FACTS For supply air Adjustable air deflectors Cleanable Installed using mounting frames FHB / FHA or commissioning box TRG Standard colour White RAL 900 -- alternative
More informationDKC. VARIZON Displacement unit with adjustable spread pattern
VARIZON Displacement unit with adjustable spread pattern Quick facts Adjustable spread pattern and affected area Suitable for all types of room which require large airflows Simple installation Cleanable
More informationIBIS. Duct diffuser with discs for supply air QUICK FACTS
Duct diffuser with discs for supply air QUICK FACTS 0 flexible distribution pattern Suspended installation Easy installation Modular length: 00 mm Standard colour White RAL 900 -- alternative standard
More informationdiffusers F24 PERFORMANCE DATA PERFORMANCE DATA ML-37 / ½" SLOT SPACING WIDTH / SUPPLY WITH CONTINUOUS PLENUM Throw correction multiplier for length
ML-37 / ½" SLOT SPACING WIDTH / SUPPLY WITH CONTINUOUS PLENUM 5-Slot 6-Slot 7-Slot 8-Slot Airflow, cfm/ft. 5 10 16 21 26 31 36 42 47 NC (Noise Criteria) - - 20 27 32 37 40 44 46 Horizontal 1-1-6 3-6-12
More informationBAR GRILLE TYPE: A-600
Tel: Sales 0 I Web: www.grada.co.uk TYPE: A00 Installation dimensions AC00 AA00* / AD00 + GR00 0. (+0)(L+0)* / (+0)(L+0) (0)(L0) 0* () (L) ( L) AB00* / AE00 + GR00 (+0)(L+0)* / (+0)(L+0) (0)(L0) 0* ( L)
More informationIBISTM. Duct diffuser with discs for supply air
TM Duct diffuser with discs for supply air Quick facts 0 flexible distribution pattern High induction capacity Suspended installation Easy installation Modular length: 00 mm Available in alternative colours
More informationLOCAL EXTRACTORS. The ideal extractor for industrial environments. Pure advantage
The ideal extractor for industrial environments. New technology in combination with new materials and a focus on design gives Movex PR many new and important advantages: - Unique ease of maneuverability.
More informationVIREO Ceiling with ALX
Square ceiling air diffuser with nozzles for supply air, with plenum box QUICK FACTS Flush design Suitable for VAV-applications Fast and easy installation Sealing ring, standard for spigot Energy efficient
More informationPerforated diffuser PAKA, PBKA, PCKA, PDKA, PEKA
Perforated diffuser PAKA, PBKA, PCKA, PDKA, PEKA TECHNICAL DATA - 0 page Perforated diffuser PAKA, PBKA, PCKA, PDKA, PEKA Diffusers with perforated panels type PAKA, PBKA, PCKA, PDKA, PEKA can be used
More informationCeiling diffusers - visible
Ceiling diffusers - visible About Lindab Comfort and Design Product overview / symbols Theory Ceiling diffusers Ceiling diffusers - visible Plenum boxes Wall diffusers Nozzles Ventiduct Grilles Displacement
More informationLaboratory Exhaust Systems
Laboratory Exhaust Systems Vektor -H Performance High Plume April 07 Laboratory Exhaust Systems Model Vektor -H Table of Contents Vektor-H Specification Chart.... Plume Height Calculation... Quick Select
More informationLOOK hidden linear diffusers
hidden linear diffusers MADEL The hidden linear diffusers are designed to combine the aesthetics with the technical performance. They can be mounted in false ceilings hiding the frame with filler and leaving
More informationSquare swirl diffuser PZK(A,B), PWK(A,B)
Square swirl diffuser PZK(A,B), PWK(A,B) TECHNICAL DATA - 01 page 4 Square swirl diffuser PZK(A,B), PWK(A,B) PZK(A,B) and PWK(A,B) diffusers assort to swirl devices group. Diffuser s gaps are equipped
More informationAIR CONDITIONING PRODUCTS COMPANY
Quality Products for Air Movement Equipment AIR CONDITIONING PRODUCTS COMPANY all Shutter Backdraft Damper Ceiling Shutter Motorized Damper Fixed Louver Ga le Shutter Drainable Louver Supply Damper Fiberglass
More informationINSTALLATION INSTRUCTIONS
INSTALLATION FORM# 597A-0711 (Replaces 597A- 1004) UNIT FILTER PLENUM CONTROL MOTOR ECONOMIZER FRESH AIR EXHAUST AIR ROOF CURB FLEXIBLE DUCT CON CEN TRIC DIFFUSER BOX INSTALLATION FLUSH MOUNT SYSTEMS Flush
More informationS u p p l y a i r h o o d J S I
Supply air hood JSI PAGE Table of Contents Product description & Product code Functioning principle, Parts Dimensions Positioning, Design Service Exhaust air Pressure loss & sound data Supply air 9 Supply
More informationRegolo Perimeter System Reveal the Texture
Regolo Perimeter System Reveal the Texture ed Technology Nulite s Regolo Perimeter System is modular in design. The slender profile is ideal for highlighting textured walls in corridors, offices, lobbies
More informationVentilation grille. Dimensions
Ventilation grille B0 Dimensions B+/A+ B-/A- Description B0 is a rectangular aluminium grille with fixed horizontal bars. B0 is used for both supply and exhaust air, and is supplied as standard with springs
More informationWebb Core Cleanroom Wall System
Webb Core Cleanroom Wall System PART 1 GENERAL 1.1 WORK INCLUDED A. This Section specifies the requirements necessary to furnish, install and complete a cleanroom wall system (CRW) including, but not limited
More informationFilter Fan Unit LIGHT
Filter Fan Unit LIGHT Type LIGHT EC Technical Concept Technical Concept Filter Fan Unit LIGHT Product Description Filter Fan Units (FFUs) from M+W Products are designed to provide clean air to individual
More informationFALCON High Flow. Circular ceiling air diffuser for supply air QUICK FACTS
Circular ceiling air diffuser for supply air QUICK FACTS Ceiling air diffuser for supply air in rooms with high ceiling Manual operated change of spread direction as standard Motor operated change of spread
More informationLEE DAN COMMUNICATIONS, INC.
THE NAME TO KNOW IN POSTAL SPECIALTIES LEE DAN COMMUNICATIONS, INC. 155 Adams Avenue, Hauppauge NY 11788-3699 YEAR AFTER YEAR, S U G G E S T E D S P E C I F I C A T I O N S OUR REPUTATION IS BASED ON PERFORMANCE
More informationInstallation and Operation Instructions I/CO 2, I/CO 2 -VDC, I/CO 2 -T
Installation and Operation Instructions I/CO 2, I/CO 2 -VDC, I/CO 2 -T READ THESE INSTRUCTIONS BEFORE YOU BEGIN INSTALLATION LOCATION The I/CO 2 transmitter is designed to mount over a standard single
More informationMCFCW-20-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 60,000 BTUH
MCFCW-20-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 60,000 BTUH 1 Chilled and Hot Water Fan Coil High Static 4-Pipe Nominal
More informationShelving. Power Track Light Shelves 2 Shelf Edge 4 Shelf Standards & Brackets 5 Flexis DisplayMaker Shelving 8
Shelving Stylmark s shelving products have clean lines that provide an attractive accent to any area. Constructed of aluminum or stainless steel, these elegant framed shelves are available with or without
More informationMCFCW-08-4LS-1 (4-Pipe) Low Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 24,000 BTUH
MCFCW-08-4LS-1 (4-Pipe) Low Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 24,000 BTUH 1 Chilled and Hot Water Fan Coil Low Static 4-Pipe Nominal Size:
More informationPowers TM Controls RL 243 MP Multi-Purpose Relay
Powers TM Controls Technical Instructions Document No. 155-042P25 RL 243-6 Description The Powers is a pneumatic auxiliary device designed to provide a variety of pneumatic control functions for the typical
More informationMCFCW-06-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 18,000 BTUH
MCFCW-06-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 18,000 BTUH 1 Chilled and Hot Water Fan Coil High Static 4-Pipe Nominal
More informationTechnical Concept. Filter Fan Unit LIGHT. Type LIGHT AC Type LIGHT EC
Technical Concept Filter Fan Unit LIGHT Type LIGHT AC Type LIGHT EC Filter Fan Unit LIGHT Technical Concept Product Description Filter Fan Units (FFUs) from M+W Products are designed to provide clean air
More informationLOCAL EXTRACTORS Pure advantages. The ideal extractor for industrial environments.
N new materials and a focus on design gives Movex PR many new and important advantages: - Unique ease of maneuverability. H - Hood designed for maximum capture PR's design is based on Movex's basic principles:
More informationLEE DAN COMMUNICATIONS, INC.
THE NAME TO KNOW IN POSTAL SPECIALTIES LEE DAN COMMUNICATIONS, INC. 55 Adams Avenue, Hauppauge NY 788-3699 YEAR AFTER YEAR, S U G G E S T E D S P E C I F I C A T I O N S OUR REPUTATION IS BASED ON PERFORMANCE
More information1.5 to 5 Tons INDOOR COILS CH35. Horizontal PRODUCT SPECIFICATIONS CH A - 2 F MODEL NUMBER IDENTIFICATION FEATURES
INDOOR COILS PRODUCT SPECIFICATIONS Horizontal Bulletin No. 20667 November 206 Supersedes August 206.5 to 5 Tons MODEL NUMBER IDENTIFICATION CH 35-8 A - 2 F Unit Type CH = Indoor - Horizontal Series Nominal
More informationLDK Slot Diffusers. Description. Throw directions. 2
Slot Diffusers LDK LDK Slot Diffusers Description LDK linear slot diffusers are designed to meet high comfort requirements and modern slot diffuser application standards. LDK slot diffusers, providing
More informationDIRECT DRIVE VANEAXIAL FIXED PITCH FANS
DIRECT DRIVE VANEAXIAL FIXED PITCH FANS BULLETIN 6 DECEMBER 201 Capacities to 100,000 Static pressures to WG Temperatures to 10 F. THE NEW YORK BLOWER COMPANY 660 Quincy Street Willowbrook, IL 602-0 Visit
More informationLEE DAN COMMUNICATIONS, INC.
THE NAME TO KNOW IN POSTAL SPECIALTIES LEE DAN COMMUNICATIONS, INC. 155 Adams Avenue, Hauppauge NY 11788-3699 YEAR AFTER YEAR, S U G G E S T E D S P E C I F I C A T I O N S OUR REPUTATION IS BASED ON PERFORMANCE
More informationNORDgrille Internal grilles
NORDgrille Internal grilles NORDgrille Contents RSP/RSV General grille RPS/RPV General grille RPSL/RPVL Floor grille RSO Transfer air grille RSL Transfer air grille RSM Transfer air grille RSI Exhaust
More informationNozzle diffuser DYVZ / Supply air unit DYVB TECHNICAL DATA
Nozzle diffuser DYVZ / Supply air unit DYVB TECHNICAL DATA Nozzle diffuser DYVZ / Supply air unit DYVB (DYVZ+ATVA) DYVZ DYVB (DYVZ + ATVA) The DYVB is a quiet wall mounted supply air unit that consists
More informationService poles for industrial applications
Service poles for industrial applications Ready to go. The ISS basic profile Our industry service poles bundle power, data and compressed air in a compact and robust manner. This means relocations, for
More informationHVAC Project. Comparison of Revit MEP Automatic Duct Sizing and Equal Friction Method Manual Calculations
346P HVAC Project Comparison of Revit MEP Automatic Duct Sizing and Equal Friction Method Manual Calculations ŀare Name: Date: 10 May 2010 Ben Meinke, Jimmy Principe, Richard Sniff Table of Contents Project
More informationINSTALLATION INSTRUCTIONS
Design and Assembly Envisor components are designed to function as an Equipment Screening System. Modular by Design allows for a more user-friendly installation. This instruction packet is intended to
More informationCEILING SWIRL DIFFUSER MLD
CEILING SWIRL DIFFUSER MLD Proektasi Makriyianni Ano Ilioupoli P.O.BOX: 6 P.C.: 1 Thessaloniki GREECE Tel.: +0 687 FAX: +0 68047 WEB SITE: www.aerogrammi.gr E-MAIL: info@aerogrammi.gr MLD CEILING ROUND
More informationGrille. Min. - max. dimensions
Min. - max. dimensions 1 / 0 00 0 500 2 / 0 00 0 Description is a supply grille made from aluminum with curved adjustable blades, oriented 1-way or 2-way horizontal or vertical both for wall and ceiling
More informationSmartAisle. SmartAisleTM. Energy-efficient use of existing cooling power in data centers to
SmartAisleTM SmartAisle TM Energy-efficient use of existing cooling power in data centers 1.50 to 1.58 1.49 Emerson Network Power Smart Aisle TM The consistent physical separation of cold zones from warm
More informationFeatured Products - RU Marking Standard on Hoffman brand
: Open Frame Racks CHAPTER Open frame racks are versatile solutions for mounting hubs, switches, routers and servers. Easy access to all sides simplifies maintenance and updates. Solidly constructed, Pentair
More informationRUGGED MILITARY GRADE
R4U-20A RUGGED MILITARY GRADE COTS Plus 4U ENCLOSURE Optimized for High Shock / Vibration Environments C6CHASSIS SYSTEMS ENGINEERED TO PERFORM The R4U-20A is designed to survive! Aircraft grade aluminum
More informationML200 Fanless Mini-ITX Enclosure
ML200 Fanless Mini-ITX Enclosure Assembly Guide Version 1.1 PN: ML200 1 Table of Contents I. Product Description... 3 II. Included Parts... 3 III. Basic Chassis Assembly... 5 IV. Installation... 12...
More informationSECTION PROJECTOR LIFTS AND MOUNTS. A. Refer to Section [ Submittal Procedures] [Insert section number and title].
(Specifier Note: The purpose of this guide specification is to assist the Specifier in correctly specifying AeroLift motorized projector lifts and their installation. The Specifier needs to edit these
More informationYour Clean Air Source!
In-Line Centrifugal Fans Your Clean Air Source! CENTRIFAN IN-LINE CENTRIFUGAL FAN HIGH QUALITY... HIGH EFFICIENCY... VERSATILITY CENTRIFAN IN-LINE CENTRIFUGAL FANS INDEX Centrifan Brochure Index..................
More informationEF-Series EuroFrame Gen 2 Cabinet System
Protecting your technology investment. EF-Series EuroFrame Gen 2 Cabinet System The new generation of EF-Series EuroFrame Cabinet is a reliable and economical cabinet solution that supports rack-mount
More informationIdeal protection for your electrics: häwa cable ducts
Ideal protection for your electrics: häwa cable ducts Well Conceived The häwa group has established itself as an innovative and highly competent supplier to machinery and facility equipment companies in
More informationSwirl diffusers, Variable swirl diffusers Swirl diffusers
Swirl diffuser O-8 Square or round front plate with radial deflector arrangement Plastic deflectors Possible olume control damper in spigot Foam sealing on the flange St RA 900 C VENTIATING GRIES, VENTIATING
More information1700 SERIES WINDOW COLLECTION
ALSIDE NEW CONSTRUCTION 1700 SERIES WINDOW COLLECTION SIZE GUIDE TABLE OF CONTENTS 3 Specifications 4 Quick Spec Guide 5 Single-Hung Model 1700 14 Twin Single-Hung Model 1720 22 Triple Single-Hung Model
More informationVariable Flow Rate Control Unit
VAV Produktdata TEKNISK DOKUMENTATION VENTILATION BG BURCHARTH A/S Variable Flow Rate Control Unit Model BVAV-R: VAV unit that has circular section. BVAV-RS: VAV terminal unit. BVAV-Q: VAV unit that has
More informationMultitronic. Technical data
Multitronic EMC Aluminium enclosure system for MCR technology Integrated guide grooves for PCB s External mounting slots with spring nuts Technical data Material: DIN EN 573 EN AW-AlMgSi Ingress protection:
More informationCatalogue. Swirl 5. Ceiling Swirl Diffuser Fixed Air Pattern.
Catalogue Swirl Ceiling Swirl Diffuser Fixed Air Pattern www.air-diffusion.co.uk sales@air-diffusion.co.uk Content Introduction... Technical Description... Performance Data... Quick Selection Data... Selection
More informationSECTION 5 -- EQUIPMENT LAYOUT & EQUIPMENT ENVIRONMENTS
SECTION 5 -- EQUIPMENT LAYOUT & EQUIPMENT ENVIRONMENTS CONTENTS PAGE 1. GENERAL... 5-1 1.1. Introduction... 5-1 1.2. Equipment Layout Requirements... 5-1 2. EQUIPMENT FRAMES... 5-2 2.1. Introduction...
More informationBrief description. Type overview
echnical data sheet VAV-Compact D3 VAV-Compact controller with integrated pressure sensor, VAV controller and damper actuator for pressure-independent VAV and CAV applications in the comfort zone Control:
More informationJet nozzle, type DW-N2 Swivel jet nozzle, type DW-V2 Twist nozzle, type DW-V2-...-DR
, type DW-N Swivel jet nozzle, type DW-V Twist nozzle, type DW-V-...-DR DS 1 E 0.00/ and twist nozzle Preliminary remarks It is advisable to use nozzles to air-condition large spaces where the supply air
More informationDL-FLEX- CHANNEL FEATURE MATRIX SUGGESTED MOUNTING TECHNIQUES. Type. Project CHANNELS FOR DL-FLEX SERIES MOUNTING CHANNELS. Catalog No.
CHANNEL FEATURE MATRIX ROUGH-IN MEDIUM DEPTH PROFILE SMALL DEPTH PROFILE BASIC CH-RI-11 CH-RI-12 CH-RI-13 CH-RI-14 CH-ME-21 DL-FLEX-UP DL-FLEX-HO DL-FLEX-UP-ULTRA DL-FLEX-HD DL-FLEX-UP-RGB DL-FLEX-UP-CTA
More informationWhat do you want to build today?
RELIABLE. RESPONSIVE. RELIABLE. RESPONSIVE. RELIABLE. RESPONSIVE. RELIABLE. RESPONSIVE. RELIABLE. RESPONSIVE. What do you want to build today? T - S L O T T E D A L U M I N U M E X T R U S I O N S V.3
More informationSwirl diffusers, Variable swirl diffusers Swirl diffusers
Swirl diffuser OD-7 Fixed blades Different installation possibilities Three possible diffuser shapes St R 90 CD OD-7/R OD-7/K OD-7/RC OD-7/K/PM F 9 x9 φd1 C C F x F C φ D2 φ D 1 9 x 9 Size ФD1 ФD2 ФD F
More informationKnurr Miracel Server Rack
Knurr Miracel Server Rack Knurr Server Racks are featured in these Scenarios: Scenario A 1-2 Rack page 8 Scenario C 3-6 Racks page 12 Scenario D 7-10 Racks page 14 Scenario E 10-30 Racks page 16 Scenario
More informationROLLING COUNTER SHUTTERS
500 ROLLING COUNTER SHUTTERS EXCEPTIONAL SECURITY AND AESTHETICS WAYNE DALTON COMMERCIAL DOOR SYSTEMS The Wayne Dalton Rolling Counter Shutter system provides the perfect solution for smaller openings
More informationSeries 575. Vertical Flow Modular Softwall Cleanroom. Series 575 Vertical Flow Modular Softwall Cleanroom
Series 575 Vertical Flow Modular Softwall Cleanroom S O L U T I O N S The Series 575 softwall cleanroom is a cost-effective method of providing quality particulate control in a softwalled enclosure. The
More informationFlatwall. Aesthetic value and functional integration for home automation
Flatwall Aesthetic value and functional integration for home automation 2 MyHOME FLATWALL Index 2-13 General features 14-33 General rules for installation 34-39 Catalogue MyHOME FLATWALL 240-270 2 MyHOME
More informationCATALOG NUMBER PROJECT W2 TRACK AND COMPONENTS
CATALOG NUMBER TYPE PROJECT W2 TRACK AND COMPONENTS Description W2 120V or 277V Track system provides two separate 20 AMP circuits and two neutrals. Each circuit can be independently switched. Fully polarized
More informationAir Gauges are ideally suited to both harsh and controlled environments, as the Air Flow disperses coolants, oil, dust, etc., from the measuring area
Air Gauges are ideally suited to both harsh and controlled environments, as the Air Flow disperses coolants, oil, dust, etc., from the measuring area allowing high magnification measurement right at the
More informationIncorporating V2.2. Product spec >>> > Series CD - Ceiling diffusers
Incorporating V2.2 Product spec >>> > Series CD - Ceiling diffusers Diffusers Ceiling (Louvre faced) Recommended for: Ceiling Supply Overview Excellent diffusion characteristics CD4 tile replacers normally
More informationSealed Enclosure Cooling Air Conditioners
SPECTRACOOL Compact Indoor INDUSTRY STANDARDS UL/cUL Listed; Type 12; File No. SA6453 for N17 UL/cUL Listed; Type 12, 3R, 4, 4X optional; File No. SA6453 and UR/cUR Recognized on select models for N16
More informationIRONRIDGE PRODUCT CATALOG
IRONRIDGE PRODUCT CATALOG Effective March 15, 2011 Product Catalog March 15, 2011 2 What s New: 1. New Products: a. End Caps for XRS and XRL Rails Page 6 b. End Clamps I, J, K, Page 7 and updated sizing
More informationProbably the fastest enclosure in the world
95 9 enclosure system Probably the fastest enclosure in the world Sample configuration tools required no no tools required Vitaro can be assembled within less than 60 seconds. 00:00 00:0 00:08 00: 00:5
More informationFixed Blade External Louvre
Fixed Blade External Louvre Models FBL and FBL 75 Model FBL Aluminium Construction Bird Wire Guard Standard Two Flange Widths 25mm or 44mm Slim 50mm Section Profile Intake or Exhaust Applications Single
More informationBrief description. Type overview
echnical data sheet VAV-Compact D3 VAV-Compact controller with integrated pressure sensor, VAV controller and damper actuator for pressure-independent VAV and CAV applications in the comfort zone Control:
More informationDesign and Installation Challenges: Aisle Containment Systems
Design and Installation Challenges: Aisle Containment Systems 1 We all know the Benefits of Containment 1. Reduces Total Cost of Data Center Ownership 2. Eliminates hot spots 3. Supports higher heat and
More informationHardwall & Softwall Cleanrooms
Hardwall & Softwall Cleanrooms 1467 Pinewood St * Rahway, NJ 07065 * 732 381-8200 * www.lmairtech.com *Email-- Sales@LMAIRTECH.com Hardwall & Softwall Cleanrooms MDR Series Modular Hardwall Cleanrooms
More information1450 First Ave. Page 1 of 7 Chippewa Falls, WI (800) or (715) Fax: (715)
1450 First Ave. Page 1 of 7 Model DA30 User Manual 1450 First Ave. Page 2 of 7 Warranty This product is fully warranted against defective materials and/or workmanship for a period of one year after purchase,
More informationStarnet Access Flooring. Low-Profile Wire Management System
Starnet Access Flooring Low-Profile Wire Management System ASM Easy to install, completely adaptable, low-profile wire management flooring system for new construction and renovation to existing office
More informationDWYER INSTRUMENTS, INC. Series AVUL Air Velocity Transmitter. Specifications - Installation and Operating Instructions.
Series AVUL Air Velocity Transmitter Specifications - Installation and Operating Instructions Bulletin P-AVUL 3-49/64 [95.71] 2-43/64 [67.92] 1/2 NPS 3-3/16 [80.81] 1-19/32 [40.59] 31/32 24.58 3-33/64
More informationAir Moving Solutions. axipal adjustable pitch airfoil fans
Air Moving Solutions. axipal adjustable pitch airfoil fans ATAD ATAB CATALOG AX210 December 2012 AdjustablePitch Models ATAD ATAB Model ATAD Arrangement 4 - Direct Drive The ATAD Adjustable Pitch Airfoil
More information1.5 to 5 Tons INDOOR COILS C35. Upflow - Cased and Uncased PRODUCT SPECIFICATIONS C A - 2 F - 1 MODEL NUMBER IDENTIFICATION FEATURES
INDOOR COILS C35 PRODUCT SPECIFICATIONS Upflow - Cased and Uncased Bulletin No. 20666 February 208 Supersedes November 206.5 to 5 Tons MODEL NUMBER IDENTIFICATION Unit Type C = Indoor Coil = Upflow Series
More informationKnürr Synergy The New Product Family For Uniform Equipment In Your Control Room. Knürr Technical Furniture
The New Product Family For Uniform Equipment In Your Control Room Knürr Technical Furniture Knürr Synergy The New Product Family Knürr offers a product family for uniform equipment and furnishing in the
More informationUser Manual. Heavy Duty Hot Wire CFM Thermo-Anemometer. Model
User Manual Heavy Duty Hot Wire CFM Thermo-Anemometer Model 407119 Introduction Congratulations on your purchase of the Extech 407119 Thermo-Anemometer. The 407119 measures air velocity, air volume, and
More informationProducts no longer available
echnical data sheet NV4-MF(-) Modulating linear actuator for -way and 3-way globe valves Actuating force 1000 N Nominal voltage AC/DC 4 V Modulating control DC 0... 10 V Position osition feedback feedbac
More informationGrilles Type AR. AE for return air 1 / 1.3 / B / 1
Grilles Type for return air 1 / 1 / B / 1 Contents Description Construction Cover Page 1 Contents 2 Description 2 Construction 2 Materials Standard Sizes Technical Data Technical Data Type Nomenclature
More informationCreating the Perfect Data Center Environment
Creating the Perfect Data Center Environment A wide range of factory laminated HPL and static dissipative floor coverings are available. The perfect data center environment requires the ability to handle
More informationPCI-SIG ENGINEERING CHANGE NOTICE
PCI-SIG ENGINEERING CHANGE NOTICE TITLE: PCIe CEM Thermal Reporting DATE: May 18, 2017 AFFECTED DOCUMENT: PCI Local Bus Specification Revision 3.0 PCI Express Card Electromechanical Specification 3.0 SPONSOR:
More informationSYSTEM WORLD PRODUCT INFO
SYSTEM WORLD PRODUCT INFO August 208 System case.. System Case Configuration.. Width x depth x height (inches).56 x 0.62 x 3.3 inches Number of System Boxes Material Lid Type Art. No. Empty* ABS Black
More informationWarning. Important. Always follow all local building electrical codes. PECCSUN3672DB46M PECCSUN3672EN46M
INSTALLATION INSTRUCTIONS PECCSUN672 Series Power Exhaust for York - 6 Ton Units Before Starting Installation Warning Severe injury can result from incorrect servicing. Only qualified HVAC service personnel
More informationHIGH EFFICIENCY 15 and 17 SEER TWO STAGE HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT. Min. Circuit Ampacity
ENVIRONMENTALLY SOUND REFRIGERANT C4H(5, 7) Product Specifications HIGH EFFICIENCY 15 and 17 TWO STAGE HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 2, 3, 4, and 5 TONS SPLIT SYSTEM 208 / 230 Volt,
More informationHeavy Duty Hot Wire CFM Thermo-Anemometer
User's Guide 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extecch 407119 Product Page Heavy Duty Hot Wire CFM Thermo-Anemometer
More informationSERIES SS. Air Steel PUBLICATION GRILLES 16 JAN 2015
PUBLICATION GRILLES 16 JAN 2015 - Wide Selection of Designs and Styles - Flexible Size Range - Natural Stainless Steel Finish Introduction Gilberts Series SS Airsteel. With this new Series Gilberts provide
More informationWhere s the Heat Coming From. Leland Sparks Global Account Technical Consultant Belden
Where s the Heat Coming From Leland Sparks Global Account Technical Consultant Belden What is the greatest DC challenge you face? Air Flow to Heat Load Relation Server Inlet Fans Chips Outlet LOAD Dell
More informationROL and ROL-S. climecon.fi
ROL and ROL-S The stylish and silent nozzle duct ROL is designed for rooms requiring large air volumes distributed evenly and without draught. The functional entity is completed by the ROL-S Adjustment
More informationPRESET HOUR METER. FEATURES 1. Preset function equipped in half size (24 48 mm inch). 2. Display has backlight for instant recognition.
PRESE HOUR MEER Hour Meter FEAURES 1. Preset function equipped in half size (24 48 mm.94 1.89 inch). 2. Display has backlight for instant recognition. ime counting iming up Red or (Green) (backlight) 3.
More information1450 First Ave. Page 1 of 9 Chippewa Falls, WI (800) or (715) Fax: (715)
1450 First Ave. Page 1 of 9 Model DA40V User Manual 1450 First Ave. Page 2 of 9 Warranty This product is fully warranted against defective materials and/or workmanship for a period of one year after purchase,
More information