diffusers F24 PERFORMANCE DATA PERFORMANCE DATA ML-37 / ½" SLOT SPACING WIDTH / SUPPLY WITH CONTINUOUS PLENUM Throw correction multiplier for length

Size: px
Start display at page:

Download "diffusers F24 PERFORMANCE DATA PERFORMANCE DATA ML-37 / ½" SLOT SPACING WIDTH / SUPPLY WITH CONTINUOUS PLENUM Throw correction multiplier for length"

Transcription

1 ML-37 / ½" SLOT SPACING WIDTH / SUPPLY WITH CONTINUOUS PLENUM 5-Slot 6-Slot 7-Slot 8-Slot Airflow, cfm/ft NC (Noise Criteria) Horizontal Vertical Airflow, cfm/ft NC (Noise Criteria) Horizontal Vertical Airflow, cfm/ft NC (Noise Criteria) Horizontal Vertical Airflow, cfm/ft NC (Noise Criteria) Horizontal Vertical Airflow, cfm/ft NC (Noise Criteria) Horizontal Vertical Airflow, cfm/ft NC (Noise Criteria) Horizontal Vertical Airflow, cfm/ft NC (Noise Criteria) Horizontal Vertical Airflow, cfm/ft NC (Noise Criteria) Horizontal Vertical NC corrections for various diffuser lengths Length Supply Return Throw correction multiplier for length Length Throw Correction Performance notes appear at end of performance data

2 ML-38, -TZ / ¾" SLOT SPACING WIDTH / SUPPLY WITH CONTINUOUS PLENUM 5-Slot 6-Slot 7-Slot 8-Slot Airflow, cfm/ft NC (Noise Criteria) Horizontal Vertical Airflow, cfm/ft NC (Noise Criteria) Horizontal Vertical Airflow, cfm/ft NC (Noise Criteria) Horizontal Vertical Airflow, cfm/ft NC (Noise Criteria) Horizontal Vertical Airflow, cfm/ft NC (Noise Criteria) Horizontal Vertical Airflow, cfm/ft NC (Noise Criteria) Horizontal Vertical Airflow, cfm/ft NC (Noise Criteria) Horizontal Vertical Airflow, cfm/ft NC (Noise Criteria) Horizontal Vertical NC corrections for various diffuser lengths Length Supply Return Throw correction multiplier for length Length Throw Correction Performance notes appear at end of performance data 25

3 26 ML-39 / 1" SLOT SPACING WIDTH / SUPPLY WITH CONTINUOUS PLENUM Airflow, cfm/ft NC (Noise Criteria) Horizontal Vertical Airflow, cfm/ft NC (Noise Criteria) Horizontal Vertical Airflow, cfm/ft NC (Noise Criteria) Horizontal Vertical Airflow, cfm/ft NC (Noise Criteria) Horizontal Vertical Airflow, cfm/ft Slot NC (Noise Criteria) Horizontal Vertical Airflow, cfm/ft Slot NC (Noise Criteria) Horizontal Vertical Airflow, cfm/ft Slot NC (Noise Criteria) Horizontal Vertical Airflow, cfm/ft Slot NC (Noise Criteria) Horizontal Vertical NC corrections for various diffuser lengths Throw correction multiplier for length Length Supply Return Data obtained from tests conducted in accordance with ANSI/ ASHRAE Standard Actual performance, with flexible duct inlet, may vary in the field. See the engineering section of this catalog for additional information. Horizontal throw values given are for terminal velocities of 150, 100 and 50 fpm Throw values given are for isothermal conditions, and are based on 4-foot active section. or other lengths, see the Throw Correction Table. Pressure is given in inches of WG for ML only Vertical throw values are given for terminal velocities of 50 fpm or divided throw, use the cfm-per-foot value for the number of slots in each direction. or sound, use the NC values for cfm-perfoot for the total number of slots. Length Throw Correction Each NC value represents the noise criteria curve which will not be exceeded by the sound pressure in any of the octave bands, 2nd through 7th, with a room absorption of 10 db, re watts or vertical throw, deduct 11 NC Dash (-) in space denotes an NC value of less than 10 NC is based on 4-foot lengths; for other lengths use the NC correction table Throws listed are for the 1-way pattern. or divided airflow, select the airflow in each direction according to the number of slots aimed in that direction, with the total airflow apportioned between slots. or an explanation of catalog throw data, see the Engineering Guidelines section of the catalog. Data obtained using plenums with duct velocities less than 800 fpm. See model MP (pages 34-45) for data with Titus plenums. or continuous lengths it is recommended that maximum active lengths are no longer than 10 feet

4 ML-40 / 1½" SLOT SPACING WIDTH / SUPPLY WITH CONTINUOUS PLENUM Number of Total Pressure Airflow, cfm/ft NC (Noise Criteria) Horizontal Vertical Airflow, cfm/ft NC (Noise Criteria) Horizontal Vertical Airflow, cfm/ft NC (Noise Criteria) Horizontal Vertical Airflow, cfm/ft NC (Noise Criteria) Horizontal Vertical Throw correction table for lengths ML-40 length (ft) Correction factor NC correction table for lengths ML-40 length (ft) Correction factor Data obtained from tests conducted in accordance with ANSI/ ASHRAE Standard Actual performance, with flexible duct inlet, may vary in the field. Refer to the engineering section of the catalog for additional information. Throw values given are for isothermal conditions, and are based on 6-foot active section. or other lengths, see the Throw Correction Table. Horizontal throw values given are for terminal velocities of 150, 100 and 50 fpm Vertical throw values given are for terminal velocity of 50 fpm Throws listed are for the 1-way pattern or divided throw, use the cfm-per-foot value for the number of slots in each direction. or sound, use the NC values for cfm-perfoot for the total number of slots. Pressure is given in inches of water gauge (WG) Each NC value represents the noise criteria curve which will not be exceeded by the sound pressure in any of the octave bands, 2nd through 7th, with a room absorption of 10 db, re watts or vertical throw, deduct 11 NC Dash (-) in space denotes an NC value of less than 10 NC is based on 6-foot lengths. or other lengths use the NC correction table above. Data was obtained using plenums with duct velocities less than 800 fpm. See model MP (pages 34-45) for data with Titus plenums. or continuous lengths, a one foot blankoff should be used in between every 6 foot active section. A two foot blankoff should be used in between 10 foot active sections. Active sections should not exceed 10 feet without a blankoff. or continuous lengths it is recommended that maximum active lengths are no longer than 10 feet 27

5 RETURN OR PLENUM APPLICATIONS All pressures are in inches of water NC values are based on a room absorption of 10 db, re watts, with a 10-foot active diffuser section (see the table below) Dash ( ) in space denotes NC value less than 10 Data obtained from tests conducted in accordance with ANSI/ASHRAE Standard or continuous lengths it is recommended that maximum active lengths are no longer than 10 feet MLR-37 No. of Negative SP cfm per ft NC cfm per ft NC cfm per ft NC cfm per ft NC cfm per ft NC cfm per ft NC cfm per ft NC cfm per ft NC NC Correction for Various MLR Lengths Length (ft.) MLR MLR-38, -TZ No. of Negative SP cfm per ft NC cfm per ft NC cfm per ft NC cfm per ft NC cfm per ft NC cfm per ft NC cfm per ft NC cfm per ft NC MLR-39 No. of Negative SP cfm per ft NC cfm per ft NC cfm per ft NC cfm per ft NC cfm per ft NC cfm per ft NC cfm per ft NC cfm per ft NC

6 MLR-40 Number of Negative Static Pressure Airflow, cfm/ft NC (Noise Criteria) Airflow, cfm/ft NC (Noise Criteria) Airflow, cfm/ft NC (Noise Criteria) Airflow, cfm/ft NC (Noise Criteria) NC correction table for lengths ML-40 length (ft) Correction factor Data obtained from tests conducted in accordance with ANSI/ ASHRAE Standard Pressure is given in inches of water gauge (WG) NC values are based on a room absorption of 10 db, re watts, with a 10-foot active diffuser section. or other lengths, refer to the NC correction table above. Dash (-) in space denotes an NC value of less than 10 or continuous lengths it is recommended that maximum active lengths are no longer than 10 feet 29

PERFORMANCE DATA SCD. SCD 12 in. x 12 in. Face Size. SCD 20 in. x 20 in. Face Size. Square Cone Diffuser

PERFORMANCE DATA SCD. SCD 12 in. x 12 in. Face Size. SCD 20 in. x 20 in. Face Size. Square Cone Diffuser 12 in. x 12 in. Face 4 Neck Velocity (fpm) 400 00 00 00 00 900 00 1200 1400 0 Velocity Pressure (in. w.g.)..01.022.031.040.00.02.090.122..013.021.030.041.04.0.04.121.1.21 Flow Rate (cfm) 3 44 2 1 0 4 122

More information

FALCON High Flow. Circular ceiling air diffuser for supply air QUICK FACTS

FALCON High Flow. Circular ceiling air diffuser for supply air QUICK FACTS Circular ceiling air diffuser for supply air QUICK FACTS Ceiling air diffuser for supply air in rooms with high ceiling Manual operated change of spread direction as standard Motor operated change of spread

More information

Perforated diffuser PAKA, PBKA, PCKA, PDKA, PEKA

Perforated diffuser PAKA, PBKA, PCKA, PDKA, PEKA Perforated diffuser PAKA, PBKA, PCKA, PDKA, PEKA TECHNICAL DATA - 0 page Perforated diffuser PAKA, PBKA, PCKA, PDKA, PEKA Diffusers with perforated panels type PAKA, PBKA, PCKA, PDKA, PEKA can be used

More information

Laboratory Exhaust Systems

Laboratory Exhaust Systems Laboratory Exhaust Systems Vektor -H Performance High Plume April 07 Laboratory Exhaust Systems Model Vektor -H Table of Contents Vektor-H Specification Chart.... Plume Height Calculation... Quick Select

More information

VIREO Ceiling with ALX

VIREO Ceiling with ALX Square ceiling air diffuser with nozzles for supply air, with plenum box QUICK FACTS Flush design Suitable for VAV-applications Fast and easy installation Sealing ring, standard for spigot Energy efficient

More information

DRI. VARIZON Displacement unit with adjustable spread pattern

DRI. VARIZON Displacement unit with adjustable spread pattern VARIZON Displacement unit with adjustable spread pattern Quick facts Adjustable spread pattern and affected area Suitable for all types of rooms Cleanable Air volume measuring point Very simple to install

More information

Slot diffusers, Round duct diffusers IMP Klima 04 Slot diffusers Round duct diffusers 176

Slot diffusers, Round duct diffusers IMP Klima 04 Slot diffusers Round duct diffusers 176 B 0 LD- F 9. φ D H H a 8.5 5 5 A E 7 LD- F 8 8.5 9. 5 5 A 7 E LD-/ LD-/ LD- O/ LD- O/ LD- O/ LD- O/.5.5.5.5 LD-/ LD-/ LD-/ LD-/ LD-/ LD-/ 7.5 7.5 07 LD- O/ LD- O/ LD- O/ LD- O/ 5.5 5.5 5.5 5.5 9.5 87.5

More information

Nozzle diffuser DYVZ / Supply air unit DYVB TECHNICAL DATA

Nozzle diffuser DYVZ / Supply air unit DYVB TECHNICAL DATA Nozzle diffuser DYVZ / Supply air unit DYVB TECHNICAL DATA Nozzle diffuser DYVZ / Supply air unit DYVB (DYVZ+ATVA) DYVZ DYVB (DYVZ + ATVA) The DYVB is a quiet wall mounted supply air unit that consists

More information

IBISTM. Duct diffuser with discs for supply air

IBISTM. Duct diffuser with discs for supply air TM Duct diffuser with discs for supply air Quick facts 0 flexible distribution pattern High induction capacity Suspended installation Easy installation Modular length: 00 mm Available in alternative colours

More information

IBIS. Duct diffuser with discs for supply air QUICK FACTS

IBIS. Duct diffuser with discs for supply air QUICK FACTS Duct diffuser with discs for supply air QUICK FACTS 0 flexible distribution pattern Suspended installation Easy installation Modular length: 00 mm Standard colour White RAL 900 -- alternative standard

More information

DKC. VARIZON Displacement unit with adjustable spread pattern

DKC. VARIZON Displacement unit with adjustable spread pattern VARIZON Displacement unit with adjustable spread pattern Quick facts Adjustable spread pattern and affected area Suitable for all types of room which require large airflows Simple installation Cleanable

More information

SLOT DIFFUSERS ALS SERIES SLOT DIFFUSER ALS37. The Airvector exclusive UNIFLEX pattern and volume controller Deflector-damper

SLOT DIFFUSERS ALS SERIES SLOT DIFFUSER ALS37. The Airvector exclusive UNIFLEX pattern and volume controller Deflector-damper SLO DIFFUSERS ALS SERIES SLO DIFFUSER For, and Installation Series ALS Architectural Linear Slot Diffusers are designed for installation in the ceiling, sidewall or sill and are recommended for supplying

More information

Square swirl diffuser PZK(A,B), PWK(A,B)

Square swirl diffuser PZK(A,B), PWK(A,B) Square swirl diffuser PZK(A,B), PWK(A,B) TECHNICAL DATA - 01 page 4 Square swirl diffuser PZK(A,B), PWK(A,B) PZK(A,B) and PWK(A,B) diffusers assort to swirl devices group. Diffuser s gaps are equipped

More information

GTH. Rectangular double deflection grille QUICK FACTS

GTH. Rectangular double deflection grille QUICK FACTS Rectangular double deflection grille QUICK FACTS For supply air Adjustable air deflectors Cleanable Installed using mounting frames FHB / FHA or commissioning box TRG Standard colour White RAL 900 -- alternative

More information

Grille. Min. - max. dimensions

Grille. Min. - max. dimensions Min. - max. dimensions 1 / 0 00 0 500 2 / 0 00 0 Description is a supply grille made from aluminum with curved adjustable blades, oriented 1-way or 2-way horizontal or vertical both for wall and ceiling

More information

Floormaster DVQA, quarter-cylindrical terminals

Floormaster DVQA, quarter-cylindrical terminals Floormaster DVQA are quarter-cylindrical supply air terminals for positioning on the floor in a corner. The terminals are designed for displacement air handling in accordance with the Floormaster system

More information

BYPASS TERMINAL UNITS 3400 SERIES

BYPASS TERMINAL UNITS 3400 SERIES 400 SRIS 400 SRIS "DUMP BOX" UNIQU "FLO DIVRTR" VALV Models: 400 Cooling 4R Cooling with ot ater Reheat 4R Cooling with lectric Reheat Model 400 The 400 Series Bypass Terminal Unit is a single duct pressure

More information

Samuel Tepp Engineering Seminar Topics

Samuel Tepp Engineering Seminar Topics Samuel Tepp Associates 11 Leonard Street Metuchen, New Jersey 08840 Contact: Keith Miller, Cell: 201-638-6591, kmiller@samtepp.net Samuel Tepp Engineering Seminar Topics All topics are approved for New

More information

HVAC Project. Comparison of Revit MEP Automatic Duct Sizing and Equal Friction Method Manual Calculations

HVAC Project. Comparison of Revit MEP Automatic Duct Sizing and Equal Friction Method Manual Calculations 346P HVAC Project Comparison of Revit MEP Automatic Duct Sizing and Equal Friction Method Manual Calculations ŀare Name: Date: 10 May 2010 Ben Meinke, Jimmy Principe, Richard Sniff Table of Contents Project

More information

CONTROLLING ROOFTOP UNIT (RTU) NOISE

CONTROLLING ROOFTOP UNIT (RTU) NOISE HUSHCORE Acoustical Products & Systems Technical Discussion General Information Terminology & Definitions Product Types Treatment Strategies Applications/Uses Industrial Architectural HVAC OEM Environmental

More information

State University of Nuevo Leon, Mexico Mechanical & Electrical Engineering School

State University of Nuevo Leon, Mexico Mechanical & Electrical Engineering School State University of Nuevo Leon, Mexico Mechanical & Electrical Engineering School ACOUSTICS LABORATORY SIMULATION OF THE ACOUSTIC WAVE BEHAVIOR OF DUCTS AND PLENUMS USING ANSYS JOSE DE JESUS VILLALOBOS

More information

1450 First Ave. Page 1 of 7 Chippewa Falls, WI (800) or (715) Fax: (715)

1450 First Ave. Page 1 of 7 Chippewa Falls, WI (800) or (715) Fax: (715) 1450 First Ave. Page 1 of 7 Model DA30 User Manual 1450 First Ave. Page 2 of 7 Warranty This product is fully warranted against defective materials and/or workmanship for a period of one year after purchase,

More information

Fundamentals of CFD and Data Center Cooling Amir Radmehr, Ph.D. Innovative Research, Inc.

Fundamentals of CFD and Data Center Cooling Amir Radmehr, Ph.D. Innovative Research, Inc. Minneapolis Symposium September 30 th, 2015 Fundamentals of CFD and Data Center Cooling Amir Radmehr, Ph.D. Innovative Research, Inc. radmehr@inres.com Learning Objectives 1. Gain familiarity with Computational

More information

PCI-SIG ENGINEERING CHANGE NOTICE

PCI-SIG ENGINEERING CHANGE NOTICE PCI-SIG ENGINEERING CHANGE NOTICE TITLE: PCIe CEM Thermal Reporting DATE: May 18, 2017 AFFECTED DOCUMENT: PCI Local Bus Specification Revision 3.0 PCI Express Card Electromechanical Specification 3.0 SPONSOR:

More information

Power and Cooling for Ultra-High Density Racks and Blade Servers

Power and Cooling for Ultra-High Density Racks and Blade Servers Power and Cooling for Ultra-High Density Racks and Blade Servers APC White Paper #46 Richard L. Sawyer Director of Data Center Technology American Power Conversion Company 2005 APC corporation What has

More information

Adjustable swirl diffuser PDZA TECHNICAL DATA

Adjustable swirl diffuser PDZA TECHNICAL DATA Adjustable swirl diffuser PDZA TECHNICAL DATA Adjustable swirl diffuser PDZA Adjustable ceiling swirl diffuser PDZA is intended for commercial and industrial buildings with a large room volume and high

More information

IRIS Damper Application Guide

IRIS Damper Application Guide IRIS Damper Application Guide IRIS & IRIS-S S INTRODUCTION The IRIS damper is a brilliantly simple solution for fast and exact measurement, balance and control of airflow. It is ideal for supply and exhaust

More information

LDK Slot Diffusers. Description. Throw directions. 2

LDK Slot Diffusers. Description. Throw directions. 2 Slot Diffusers LDK LDK Slot Diffusers Description LDK linear slot diffusers are designed to meet high comfort requirements and modern slot diffuser application standards. LDK slot diffusers, providing

More information

Air Moving Solutions. axipal adjustable pitch airfoil fans

Air Moving Solutions. axipal adjustable pitch airfoil fans Air Moving Solutions. axipal adjustable pitch airfoil fans ATAD ATAB CATALOG AX210 December 2012 AdjustablePitch Models ATAD ATAB Model ATAD Arrangement 4 - Direct Drive The ATAD Adjustable Pitch Airfoil

More information

1450 First Ave. Page 1 of 9 Chippewa Falls, WI (800) or (715) Fax: (715)

1450 First Ave. Page 1 of 9 Chippewa Falls, WI (800) or (715) Fax: (715) 1450 First Ave. Page 1 of 9 Model DA40V User Manual 1450 First Ave. Page 2 of 9 Warranty This product is fully warranted against defective materials and/or workmanship for a period of one year after purchase,

More information

VRF. Technical Data Book. Slim duct for America (R410A, 60Hz, HP) Model : AM***FNLDCH***

VRF. Technical Data Book. Slim duct for America (R410A, 60Hz, HP) Model : AM***FNLDCH*** VRF Technical Data Book Slim duct for America (R41A, 6Hz, HP) Model : AM***FNLDCH*** History Version Modification Date Remark Ver.1. Release Slim duct for America (R41A, 6Hz, HP) 1.11.4 - Ver.1.1 1.12.28

More information

NORDgrille Internal grilles

NORDgrille Internal grilles NORDgrille Internal grilles NORDgrille Contents RSP/RSV General grille RPS/RPV General grille RPSL/RPVL Floor grille RSO Transfer air grille RSL Transfer air grille RSM Transfer air grille RSI Exhaust

More information

EQUIPMENT ENGINEERING & SPACE PLANNING DATA SYSTEM LEVEL

EQUIPMENT ENGINEERING & SPACE PLANNING DATA SYSTEM LEVEL ESP-001 Form EQUIPMENT ENGINEERING & SPACE PLANNING DATA SYSTEM LEVEL Acoustic Noise Engineering Data Physical Data Equipment System Manufacturer: Date: Product Name: Equip. Functional Description and

More information

Rectangular straight silencer

Rectangular straight silencer silencer DLD Dimensions b a l Description DLD has a conventional design with dimensions that not exceed the corresponding connection dimensions. The silencer can be manufactured in all standard duct sizes.

More information

Your Clean Air Source!

Your Clean Air Source! In-Line Centrifugal Fans Your Clean Air Source! CENTRIFAN IN-LINE CENTRIFUGAL FAN HIGH QUALITY... HIGH EFFICIENCY... VERSATILITY CENTRIFAN IN-LINE CENTRIFUGAL FANS INDEX Centrifan Brochure Index..................

More information

Grilles Type AR. AE for return air 1 / 1.3 / B / 1

Grilles Type AR. AE for return air 1 / 1.3 / B / 1 Grilles Type for return air 1 / 1 / B / 1 Contents Description Construction Cover Page 1 Contents 2 Description 2 Construction 2 Materials Standard Sizes Technical Data Technical Data Type Nomenclature

More information

APPENDIX S HORIZONTAL DIRECTIONAL DRILLING (HDD) ENVIRONMENTAL SOUND LEVEL ASSESSMENT REPORT

APPENDIX S HORIZONTAL DIRECTIONAL DRILLING (HDD) ENVIRONMENTAL SOUND LEVEL ASSESSMENT REPORT ALASKA LNG PROJECT DOCKET NO. CP17- -000 RESOURCE REPORT NO. 9 APPENDIX S HDD ENVIRONMENTAL SOUND LEVEL ASSESSMENT REPORT PUBLIC DOC NO: USAI-PE-SRREG-00-000009-000 DATE: APPENDIX S HORIZONTAL DIRECTIONAL

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION FORM# 597A-0711 (Replaces 597A- 1004) UNIT FILTER PLENUM CONTROL MOTOR ECONOMIZER FRESH AIR EXHAUST AIR ROOF CURB FLEXIBLE DUCT CON CEN TRIC DIFFUSER BOX INSTALLATION FLUSH MOUNT SYSTEMS Flush

More information

Universal Valve Module (UVM) Installation Manual Version: Triatek Universal Valve Module

Universal Valve Module (UVM) Installation Manual Version: Triatek Universal Valve Module Installation Manual Version: 05.19.16 Triatek Universal Valve Module SUBHEAD TABLE OF CONTENTS Setup Overview...3 Introduction.......4 Overview of Operation.........4 Basic Functionality of the UVM...5

More information

Hardwall & Softwall Cleanrooms

Hardwall & Softwall Cleanrooms Hardwall & Softwall Cleanrooms 1467 Pinewood St * Rahway, NJ 07065 * 732 381-8200 * www.lmairtech.com *Email-- Sales@LMAIRTECH.com Hardwall & Softwall Cleanrooms MDR Series Modular Hardwall Cleanrooms

More information

Fan-Powered VAV Terminal Units

Fan-Powered VAV Terminal Units This article was published in ASHRAE Journal, November 2017. Copyright 2017 ASHRAE. Posted at www.ashrae.org. This article may not be copied and/or distributed electronically or in paper form without permission

More information

Ventilation grille. Dimensions

Ventilation grille. Dimensions Ventilation grille B0 Dimensions B+/A+ B-/A- Description B0 is a rectangular aluminium grille with fixed horizontal bars. B0 is used for both supply and exhaust air, and is supplied as standard with springs

More information

OPEN FACE Industrial East Grand Ave., Pomona, CA Fax:

OPEN FACE Industrial East Grand Ave., Pomona, CA Fax: OPEN FACE Industrial Dry Booths Environmentally Safe Each Industrial Dry Booth is designed to meet or exceed safety and code requirements: NFPA- and IFC, to protect those that work in any industrial spray

More information

Application of TileFlow to Improve Cooling in a Data Center

Application of TileFlow to Improve Cooling in a Data Center Case Study Application of TileFlow to Improve Cooling in a Data Center 3025 Harbor Lane North, Suite 300 Plymouth, MN 55447 USA Copyright 2004 Innovative Research, Inc. 2 Introduction A large insurance

More information

Standard Construction. Options and Accessories

Standard Construction. Options and Accessories SP, SP-L, SP 22 ath and Inline ans SP SP UL/cUL 507-599 - eiling xhaust ans SP-90 and smaller and SP- are UL/cUL Listed for above bathtub/shower with I branch protected circuit. SP- is UL/cUL Listed UL/cUL

More information

FAN POWERED TERMINAL UNITS

FAN POWERED TERMINAL UNITS GENERAL PRODUT OVERVIEW Leading The Industry Providing products that incorporate the desires and requirements of the industry we serve has traditionally been a primary focus at Nailor. We listened in-depth

More information

Swirl diffusers, Variable swirl diffusers Swirl diffusers

Swirl diffusers, Variable swirl diffusers Swirl diffusers Swirl diffuser OD-7 Fixed blades Different installation possibilities Three possible diffuser shapes St R 90 CD OD-7/R OD-7/K OD-7/RC OD-7/K/PM F 9 x9 φd1 C C F x F C φ D2 φ D 1 9 x 9 Size ФD1 ФD2 ФD F

More information

Recapture Capacity for Existing. and Airflow Optimization

Recapture Capacity for Existing. and Airflow Optimization Recapture Capacity for Existing Data Centers Through Cooling and Airflow Optimization Introduction Challenges and Trends Agenda Cooling & Airflow Optimization Takeaways Learning Objectives Recognize opportunities

More information

Clean Room Certification Reports Interpreting and Acting on the Good, the Bad and the Ugly!

Clean Room Certification Reports Interpreting and Acting on the Good, the Bad and the Ugly! Clean Room Certification Reports Interpreting and Acting on the Good, the Bad and the Ugly! Marc Stranz, PharmD, Vice President of Clinical Operations BioScrip, East Greenville, PA Jim Wagner, President

More information

Specification and Design Catalog. Waterside Economizer

Specification and Design Catalog. Waterside Economizer Specification and Design Catalog Waterside Economizer Table of Contents Waterside Economizer Applications.................................................... 4 Application Notes..................................................................

More information

AccuDuct ACCA Manual-D Duct Design

AccuDuct ACCA Manual-D Duct Design AccuDuct ACCA Manual-D Duct Design Software Inside This Manual How to Input Data for Duct Design Calculations. View Design Summaries and Print Reports. Using AccuDuct on a Tablet PC. Import AccuLoad Room

More information

Reducing Data Center Cooling Costs through Airflow Containment

Reducing Data Center Cooling Costs through Airflow Containment FEATURE Reducing Data Center Cooling Costs through Airflow Containment Implementing a containment solution in the data center costs much less than the alternatives of adding air handlers or other supplemental

More information

Ceiling diffusers - visible

Ceiling diffusers - visible Ceiling diffusers - visible About Lindab Comfort and Design Product overview / symbols Theory Ceiling diffusers Ceiling diffusers - visible Plenum boxes Wall diffusers Nozzles Ventiduct Grilles Displacement

More information

Creating an Energy-Efficient, Automated Monitoring System for Temperature and Humidity at a World-Class Data Center

Creating an Energy-Efficient, Automated Monitoring System for Temperature and Humidity at a World-Class Data Center About CyrusOne CyrusOne is a world-renowned enterprise data center provider that offers 40 data centers across the U.S., Europe and Asia with a three million-plus square feet of total net rentable space.

More information

Building Loads and Dedicated Outdoor Air Systems

Building Loads and Dedicated Outdoor Air Systems AMCA International Building Loads and Dedicated Outdoor Air Systems Dan Int-Hout Chief Engineer, Krueger, Richardson, Tx. Dint-Hout@Krueger-hvac.com KRUEGER EXCELLENCE IN AIR DISTRIBUTION Air System Engineering

More information

HIGH EFFICIENCY 15 and 17 SEER TWO STAGE HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT. Min. Circuit Ampacity

HIGH EFFICIENCY 15 and 17 SEER TWO STAGE HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT. Min. Circuit Ampacity ENVIRONMENTALLY SOUND REFRIGERANT C4H(5, 7) Product Specifications HIGH EFFICIENCY 15 and 17 TWO STAGE HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 2, 3, 4, and 5 TONS SPLIT SYSTEM 208 / 230 Volt,

More information

Filter Fan Unit LIGHT

Filter Fan Unit LIGHT Filter Fan Unit LIGHT Type LIGHT EC Technical Concept Technical Concept Filter Fan Unit LIGHT Product Description Filter Fan Units (FFUs) from M+W Products are designed to provide clean air to individual

More information

High Tech Getting Too Hot? High Density Environments Require A Different Cooling Approach

High Tech Getting Too Hot? High Density Environments Require A Different Cooling Approach High Tech Getting Too Hot? High Density Environments Require A Different Cooling Approach Proper airfl ow and thermal management are the most critical aspects of designing and operating your data center,

More information

Where s the Heat Coming From. Leland Sparks Global Account Technical Consultant Belden

Where s the Heat Coming From. Leland Sparks Global Account Technical Consultant Belden Where s the Heat Coming From Leland Sparks Global Account Technical Consultant Belden What is the greatest DC challenge you face? Air Flow to Heat Load Relation Server Inlet Fans Chips Outlet LOAD Dell

More information

DuctworkPro. User Guide

DuctworkPro. User Guide DuctworkPro for AutoCAD User Guide Version 2.0, March. 2004 Copyright 2004, Randall C. Wilkinson By Randall C. Wilkinson Freeware Version Users: This document describes the Professional Version of Ductwork.

More information

Optimizing Cooling Performance Of a Data Center

Optimizing Cooling Performance Of a Data Center ASHRAE www.ashrae.org. Used with permission from ASHRAE Journal. This article may not be copied nor distributed in either paper or digital form without ASHRAE s permission. For more information about ASHRAE,

More information

itool Installation and User s Manual

itool Installation and User s Manual itool Installation and User s Manual Introduction In this Publication This manual contains instructions on how to install and operate the Tyco Safety Products itool. The itool is a software program designed

More information

DIRECT DRIVE VANEAXIAL FIXED PITCH FANS

DIRECT DRIVE VANEAXIAL FIXED PITCH FANS DIRECT DRIVE VANEAXIAL FIXED PITCH FANS BULLETIN 6 DECEMBER 201 Capacities to 100,000 Static pressures to WG Temperatures to 10 F. THE NEW YORK BLOWER COMPANY 660 Quincy Street Willowbrook, IL 602-0 Visit

More information

Heavy Duty Hot Wire CFM Thermo-Anemometer

Heavy Duty Hot Wire CFM Thermo-Anemometer User's Guide 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extecch 407119 Product Page Heavy Duty Hot Wire CFM Thermo-Anemometer

More information

APC APPLICATION NOTE #114

APC APPLICATION NOTE #114 APPLICATION NOT #4 Using the Rack Air Containment System with the InfraStruXure InRow SC By David Roden Abstract The InfraStruXure InRow SC (ACSC00 and ACSC0) is a self-contained air conditioner for server

More information

CyrusOne Case Study About CyrusOne

CyrusOne Case Study About CyrusOne CyrusOne Case Study About CyrusOne CyrusOne is a world-renowned enterprise data center provider that offers 31 data centers across the U.S., Europe and Asia with a three million-plus square feet of total

More information

HARBEC Inc Ontario, NY

HARBEC Inc Ontario, NY HARBEC Inc Ontario, NY Cleanroom Certification Report PREPARED FOR 369 Route 104 Ontario, NY 14519-8999 Paul Scheible Engineering Manager Main Cleanroom Gown Room Room Design Classification ISO Class 8

More information

Using CFD Analysis to Predict Cooling System Performance in Data Centers Ben Steinberg, P.E. Staff Applications Engineer

Using CFD Analysis to Predict Cooling System Performance in Data Centers Ben Steinberg, P.E. Staff Applications Engineer Using CFD Analysis to Predict Cooling System Performance in Data Centers Ben Steinberg, P.E. Staff Applications Engineer Agenda What is CFD? Applications of CFD Applicability to the Data Center How it

More information

Chapter 3 Practice Test

Chapter 3 Practice Test 1. Complete parts a c for each quadratic function. a. Find the y-intercept, the equation of the axis of symmetry, and the x-coordinate of the vertex. b. Make a table of values that includes the vertex.

More information

Residential air leakage measurement system comparison: Retrotec Blower Door & Minneapolis Blower Door

Residential air leakage measurement system comparison: Retrotec Blower Door & Minneapolis Blower Door Residential air leakage measurement system comparison: Retrotec Blower Door & Minneapolis Blower Door Use this guide to compare features of the two top US manufacturers. Retrotec Model 1000 Blower Door

More information

Environmental Noise Study of. Findlay Creek Public School Findlay Creek Drive, Ottawa, Ontario. R1. Prepared for: N45 Architecture Inc.

Environmental Noise Study of. Findlay Creek Public School Findlay Creek Drive, Ottawa, Ontario. R1. Prepared for: N45 Architecture Inc. Environmental Noise Study of Findlay Creek Public School 3010 Findlay Creek Drive, Ottawa, Ontario. R1 Prepared for: N45 Architecture Inc. Prepared by: Eric Sladic February 5 th, 2015 Contents 1.0 Introduction...1

More information

Model 6812 VOLUME FLOW ANEMOMETER. User Manual. Kanomax USA, Inc. 219 Route 206 PO Box 372. Andover, NJ USA. (800) Fax: (973)

Model 6812 VOLUME FLOW ANEMOMETER. User Manual. Kanomax USA, Inc. 219 Route 206 PO Box 372. Andover, NJ USA. (800) Fax: (973) Kanomax USA, Inc. 219 Route 206 PO Box 372 Andover, New Jersey 07821 USA (800) 247-8887 Fax: (973) 786-7586 Model 6812 VOLUME FLOW ANEMOMETER User Manual www.kanomax-usa.com Copyright 2008, Kanomax USA,

More information

MCFCW-20-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 60,000 BTUH

MCFCW-20-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 60,000 BTUH MCFCW-20-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 60,000 BTUH 1 Chilled and Hot Water Fan Coil High Static 4-Pipe Nominal

More information

Model 6812 VOLUME FLOW ANEMOMETER. User Manual. 219 Route 206 Phone: PO Box 372 Fax: (973)

Model 6812 VOLUME FLOW ANEMOMETER. User Manual. 219 Route 206 Phone: PO Box 372 Fax: (973) Model 6812 VOLUME FLOW ANEMOMETER User Manual Copyright 2008, Kanomax USA, Inc. Page 1 of 29 INTRODUCTION Congratulations on your purchase of a 6812 Digital Anemometer with Volume Calculation! You now

More information

Temperature monitoring and CFD Analysis of Data Centre

Temperature monitoring and CFD Analysis of Data Centre Available online at www.sciencedirect.com Procedia Engineering 56 (2013 ) 551 559 5 th BSME International Conference on Thermal Engineering Temperature monitoring and CFD Analysis of Data Centre N.M.S.

More information

MCFCW-08-4LS-1 (4-Pipe) Low Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 24,000 BTUH

MCFCW-08-4LS-1 (4-Pipe) Low Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 24,000 BTUH MCFCW-08-4LS-1 (4-Pipe) Low Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 24,000 BTUH 1 Chilled and Hot Water Fan Coil Low Static 4-Pipe Nominal Size:

More information

ENCLOSURE HEAT DISSIPATION

ENCLOSURE HEAT DISSIPATION ENCLOSURE HEAT DISSIPATION DATA CENTER SOLUTIONS A White Paper by Great Lakes Case & Cabinet Company www.werackyourworld.com 814.734.7303 Page 2 Introduction Dangerous heat levels inside an enclosure threaten

More information

Approval Block. Prepared by: Signature Date Evan Parnell 08 NOV Reviewed by: Signature Date. Approved by: Signature Date

Approval Block. Prepared by: Signature Date Evan Parnell 08 NOV Reviewed by: Signature Date. Approved by: Signature Date ATS-ATP-3440 Page: 1 of 6 Approval Block Prepared by: Signature Date Evan Parnell 08 NOV 2013 Reviewed by: Signature Date Brian Flynn 08 NOV 2013 Approved by: Signature Date Kristal Jewell 08 NOV 2013

More information

PP-8516 & PP Electronic Static Pressure Controllers and Transmitters for Cental Air Supply Systems General Instructions

PP-8516 & PP Electronic Static Pressure Controllers and Transmitters for Cental Air Supply Systems General Instructions PP-8516 & PP-8616 Electronic Static Pressure Controllers and Transmitters for Cental Air Supply Systems General Instructions Part Number PP-8516 Static Pressure Controller/Transmitter PP-8616 Static Pressure

More information

MCFCW-06-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 18,000 BTUH

MCFCW-06-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 18,000 BTUH MCFCW-06-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 18,000 BTUH 1 Chilled and Hot Water Fan Coil High Static 4-Pipe Nominal

More information

GX7300 SERIES CHASSIS AND CONTROLLERS 20 SLOT, 3U PXI CHASSIS DESCRIPTION FEATURES CONFIGURATION

GX7300 SERIES CHASSIS AND CONTROLLERS 20 SLOT, 3U PXI CHASSIS DESCRIPTION FEATURES CONFIGURATION 20 SLOT, 3U PXI CHASSIS 20 slots supporting a 3U (embedded or remote) PXI controller and 19 3U PXI or ccpi instruments Built-in peripherals (hard disk drive, and a DVD-RW drive) for embedded controller

More information

NetShelter CX Technical Guide

NetShelter CX Technical Guide NetShelter CX Technical Guide A soundproofed Server Room in a Box which allows for IT deployment wherever and whenever it is needed, saving space, cost and deployment time. Model AR4038 & AR4038I >Physical

More information

Minneapolis Blower Door Building Air tightness Testing Systems

Minneapolis Blower Door Building Air tightness Testing Systems DIAGNOSTIC TOOLS TO MEASURE BUILDING PERFORMANCE ENERGY CONSERVATORY The Blower Door Minneapolis Blower Door Building Air tightness Testing Systems Minneapolis Blower Door Blower Door tests are used to

More information

Slim duct (AMTTTFNLDEH ) Indoor units

Slim duct (AMTTTFNLDEH ) Indoor units Slim duct (AMTTTFNLDEH ) Slim duct. Specifications 1) Technical specifications Model AM22FNLDEH AM28FNLDEH AMFNLDEH AM4FNLDEH AMFNLDEH Power Supply Ø, #, V, Hz 1,2,22-24, 1,2,22-24, 1,2,22-24, 1,2,22-24,

More information

1.5 to 5 Tons INDOOR COILS CH35. Horizontal PRODUCT SPECIFICATIONS CH A - 2 F MODEL NUMBER IDENTIFICATION FEATURES

1.5 to 5 Tons INDOOR COILS CH35. Horizontal PRODUCT SPECIFICATIONS CH A - 2 F MODEL NUMBER IDENTIFICATION FEATURES INDOOR COILS PRODUCT SPECIFICATIONS Horizontal Bulletin No. 20667 November 206 Supersedes August 206.5 to 5 Tons MODEL NUMBER IDENTIFICATION CH 35-8 A - 2 F Unit Type CH = Indoor - Horizontal Series Nominal

More information

Min. Circuit Ampacity. Max. Fuse or Breaker. Ship / Operating Weight lbs. (kg) C4H524GKD 2 24,

Min. Circuit Ampacity. Max. Fuse or Breaker. Ship / Operating Weight lbs. (kg) C4H524GKD 2 24, ENVIRONMENTALLY SOUND REFRIGERANT C4H(5, 7) SXT+ Product Specifications HIGH EFFICIENCY 15 and 17 SEER TWO STAGE HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 2, 3, 4, and 5 TONS SPLIT SYSTEM 208

More information

DWYER INSTRUMENTS, INC. Series AVUL Air Velocity Transmitter. Specifications - Installation and Operating Instructions.

DWYER INSTRUMENTS, INC. Series AVUL Air Velocity Transmitter. Specifications - Installation and Operating Instructions. Series AVUL Air Velocity Transmitter Specifications - Installation and Operating Instructions Bulletin P-AVUL 3-49/64 [95.71] 2-43/64 [67.92] 1/2 NPS 3-3/16 [80.81] 1-19/32 [40.59] 31/32 24.58 3-33/64

More information

Measure Sounds Reliably

Measure Sounds Reliably Measure Sounds Reliably Sound Level Meter Class1 NL-52 Sound Level Meter Class2 NL-42 Extremely User Friendly Rion s NL-52 and NL-42 sound level meters provide full support for the process. The NL-52 and

More information

ANSYS AIM Tutorial Fluid Flow Through a Transition Duct

ANSYS AIM Tutorial Fluid Flow Through a Transition Duct ANSYS AIM Tutorial Fluid Flow Through a Transition Duct Author(s): Sebastian Vecchi, ANSYS Created using ANSYS AIM 18.1 Problem Specification Start Up Geometry Import Geometry Extracting Volume Suppress

More information

NetShelter CX Performance Guide

NetShelter CX Performance Guide NetShelter CX Performance Guide The Netshelter CX is a soundproofedd Room in a Box which allows for IT deployment wherever and whenever it is needed, saving space, cost and deployment time. Here is one

More information

LOCAL EXTRACTORS. The ideal extractor for industrial environments. Pure advantage

LOCAL EXTRACTORS. The ideal extractor for industrial environments. Pure advantage The ideal extractor for industrial environments. New technology in combination with new materials and a focus on design gives Movex PR many new and important advantages: - Unique ease of maneuverability.

More information

Surface Area and Volume

Surface Area and Volume 15 CHAPTER Surface Area and Volume Worksheet 1 Building Solids Using Unit Cubes How many unit cubes are used to build each solid? This is a unit cube. 1. 2. unit cubes 3. 4. unit cubes unit cubes unit

More information

Moving Containment Inside the Enclosure. Jeff Markle Great Lakes Case & Cabinet

Moving Containment Inside the Enclosure. Jeff Markle Great Lakes Case & Cabinet Moving Containment Inside the Enclosure Presented by Jeff Markle Great Lakes Case & Cabinet Containment Containment : To put constraint upon; to restrain; to confine; to keep within bounds Containment

More information

Installation and Operation Instructions

Installation and Operation Instructions 33ZC ComfortID Test and Balance Tool Software Installation and Operation Instructions Part Number 33ZCBAL-SA INSTALLATION The ComfortID Test and Balance Tool software requires no special installation.

More information

Acoustic Nozzle Design for Fire Protection Application

Acoustic Nozzle Design for Fire Protection Application Acoustic Nozzle Design for Fire Protection Application Melissa A. Loureiro, Alan Elder, Arash Ahmadzadegan Johnson Controls, Cranston, RI, USA Abstract Data centers are relied upon to store and distribute

More information

Model 6813 THERMO-ANEMOMETER. User Manual. Kanomax USA, Inc. 219 Route 206 PO Box 372. Andover, NJ USA. (800) Fax: (973)

Model 6813 THERMO-ANEMOMETER. User Manual. Kanomax USA, Inc. 219 Route 206 PO Box 372. Andover, NJ USA. (800) Fax: (973) Kanomax USA, Inc. 219 Route 206 PO Box 372 Andover, New Jersey 07821 USA (800) 247-8887 Fax: (973) 786-7586 Model 6813 THERMO-ANEMOMETER User Manual www.kanomax-usa.com Copyright 2008, Kanomax USA, Inc

More information

VRF Technical Data Book

VRF Technical Data Book VRF Technical Data Book Wind-Free 4Way Cassette for North America (R4A, HP) Model : AM***NN4DCH/** History Version Modification Date Remark Ver.1. Released VRF Wind-Free 4Way Cassette for north America

More information

oom Pressurization Con

oom Pressurization Con Technical Specification Sheet Rev. 3, December, 1998 Room Pressurization Controllers equipment. This approach to room control includes the following features. Features gure 1. Roo oom Pressurization Con

More information

Slim Ducted type. Contents MMD-AP 4SPH2UL MMD-AP0094SPH2UL MMD-AP0124SPH2UL MMD-AP0154SPH2UL MMD-AP0184SPH2UL

Slim Ducted type. Contents MMD-AP 4SPH2UL MMD-AP0094SPH2UL MMD-AP0124SPH2UL MMD-AP0154SPH2UL MMD-AP0184SPH2UL E5-3I D-AP 4SP2U Slim Ducted type D-AP0074SP2U D-AP0094SP2U D-AP024SP2U D-AP054SP2U D-AP084SP2U Contents. Specifications 2. Dimensions 3. Center of gravity 4. Piping diagram 5. Wiring diagram 6. Electrical

More information

BACnet Terminal Box (VAV) Controller

BACnet Terminal Box (VAV) Controller Technical Specification Sheet May 30, 2012 BACnet Terminal Box (VAV) Controller Figure 1. BACnet Terminal Box Controller. The BACnet Terminal Box Controller (Figure 1) provides high performance Direct

More information