Illinois and Northwest Indiana Metering Equipment

Size: px
Start display at page:

Download "Illinois and Northwest Indiana Metering Equipment"

Transcription

1 Illinois and Northwest Indiana Metering Equipment Technical Focus TD00000E Servicing : Ameren UE, Commonwealth Edison, Ameren IP (Illinois Power Utility), Northern Indiana and Public Service (NIPSCO)

2 Illinois and Northwest Indiana Metering Equipment Contents Description Page Meter Socket Catalog Number Logic Catalog Numbering System Product Selection by Utility Ameren UE (Union Electric & Central Illinois Public). Commonwealth Edison.. 6 Technical Data Knockout Drawings Product Selection by Utility Ameren IP (Illinois Power Utility)... 0 Northern Indiana Public Service Company NIPSCO.. Description Page Meter Packs Product Description..... Product Selection Main Tenant Circuit Breakers Product Description..... Product Selection Dimensions and Knockouts Accessories Meter Packs Technical Data Knockout Drawings EATON CORPORATION Cutler-Hammer Illinois and Northwest Indiana Metering Equipment Technical Focus TD00000E Copyright 007

3 Meter Socket Catalog Number Logic Catalog Numbering System TABLE. RS GROUP ING SYSTEM UT RS 0 B CH Standard Prefix (See Prefix Guide) See Product Group Designators Ampere Rating = 00 Amperes = 00 Amperes = 0 Amperes Service Design 0 = Overhead = Combination Overhead/ Underground = Underground, Side Wired = Combination, Overhead/ Underground, Side Wired Maximum Conductor (Line & Load) 0 = /8" Stud Connectors = #/0 Connectors = #0 kcmil Connectors = #0 kcmil Connectors Cutler-Hammer Standard Suffixes A = Solid Top B = Small Hub Opening C = Small Hub Closure Plate L = -/" Hub M = -/" Hub N = " Hub P = -/" Hub T = Large Hub Opening U = Large Hub Cover Plate V = -/" Large Hub Q = " Large Hub R = -/" Large Hub S = " Large Hub Z = Large to Small Hub Adapter Mounted NOTE: 00 CH catalog numbers are specialty sockets for individual utilities and do not follow typical catalog numbering system. RS Group = Residential Service, Single Position. Note: Some sockets that are built for specific utilities have their own unique catalog numbers. These can be found on the utility selection pages. METER SOCKET PREFIX GUIDE A = Aluminum enclosure B = Barrel lock provision, for an exposed INNER-TITE or Brooks barrel lock; unit includes an internal lock receiver bracket. F = Barrel lock with guard provision, for a lock guard INNER-TITE or Brooks barrel lock; unit includes an internal lock receiver bracket. G = Grounded fifth terminal (9 o clock position) H = bypass I = Inhibitor installed in wire connectors M = Temporary meter cover (waxed cardboard) N = No sealing ring (applies only to ring style sockets) R = Ring style socket S = Aluminum screw type sealing ring (applies only to ring style sockets) T = Grounding connector (# # Cu) for Tri-Plex ground TT = Two () grounding connectors (# # Cu) for Quad-Plex ground U = UL (Underwriters Laboratories) labeled Z = /6 Hex head connector screw in place of slotted (00 amperes only) Note: The U prefix is always used first followed by other prefixes required in alphabetical order. EATON CORPORATION Cutler-Hammer Illinois and Northwest Indiana Metering Equipment Technical Focus TD00000E July 007

4 Catalog Numbering System TABLE. R-6R AND H-6H GROUP ING SYSTEM UT R B CH Standard Prefix (See Prefix Guide on Page ) See Product Group Designators Ampere Rating = 00 Amperes = 00 Amperes Service Design 0 = Overhead = Combination Overhead/ Underground = Underground, Side Wired = Combination Overhead/ Underground, Side Wired = End Feed Maximum Conductor (Line & Load) 0 = /8" Stud Connectors = #/0 Connectors = #0 kcmil Connectors = #0 kcmil Connectors = #00 kcmil Connectors 6 = # kcmil Connectors 7 = #70 kcmil Connectors 8 = Dual #0 kcmil Connectors 9 = Dual #00 kcmil Connectors Cutler-Hammer Standard Suffixes A = Solid Top B = Small Hub Opening C = Small Hub Closure Plate L = -/" Hub M = -/" Hub N = " Hub P = -/" Hub T = Large Hub Opening U = Large Hub Cover Plate V = -/" Large Hub Q = " Large Hub R = -/" Large Hub S = " Large Hub Z = Large to Small Hub Adapter Mounted NOTE: 00 CH catalog numbers are specialty sockets for individual utilities and do not follow typical catalog numbering system. R-6R Group = Residential Service, Multiple Position. H-6H Group = Commercial or Residential Service, Multiple Position. EATON CORPORATION Cutler-Hammer Illinois and Northwest Indiana Metering Equipment Technical Focus TD00000E Copyright 007

5 Meter Socket Catalog Number Logic Catalog Numbering System TABLE. H GROUP ING SYSTEM UT H 0 B CH Standard Prefix (See Prefix Guide on Page ) See Product Group Designators Jaw Quantity = Terminal = Terminal 7 = 7 Terminal Ampere Rating = 00 Amperes = 0 Amperes Service Design 0 = Overhead = Combination Overhead/ Underground = Underground, Side Wired = Combination, Overhead/ Underground, Side Wired Maximum Conductor (Line & Load) 0 = /8 Stud Connectors = #/0 Connectors = #0 kcmil Connectors = #0 kcmil Connectors = #00 kcmil Connectors 6 = # kcmil Connectors 7 = #70 kcmil Connectors 8 = Dual #0 kcmil Connectors 9 = Dual #0 kcmil Connectors Cutler-Hammer Standard Suffixes A = Solid Top B = Small Hub Opening C = Small Hub Closure Plate L = -/" Hub M = -/" Hub N = " Hub P = -/" Hub T = Large Hub Opening U = Large Hub Cover Plate V = -/" Large Hub Q = " Large Hub R = -/" Large Hub S = " Large Hub Z = Large to Small Hub Adapter Mounted NOTE: 00 CH catalog numbers are specialty sockets for individual utilities and do not follow typical catalog numbering system. H Group = Commercial or Residential Service, Single Position (lever bypass). EATON CORPORATION Cutler-Hammer Illinois and Northwest Indiana Metering Equipment Technical Focus TD00000E July 007

6 Product Selection by Utility Ameren UE (Union Electric) 00 Ampere Single-Position Meter Socket (UTRS0BCH) 0 Ampere Lever Bypass Meter Socket (0097CH) 00 Ampere Lever Bypass Meter Socket (UTH7TCH) 00 Ampere Multi-Position Meter Socket (UTRTCH) TABLE. AMEREN UE APPROVED METER SOCKETS DIMENSIONS IN INCHES CUTLER- HAMMER CATALOG NUMBER DIMENSIONS CONNECTIONS CONCENTRIC KNOCKOUTS (SEE PAGE 8) H W D LINE LOAD 00 Ampere Single-Position Residential UTRS0BCH A, Terminal, SM Hub Open, OH/UG #8 /0 #8 / Ampere Single-Position Residential UTRS0BCH UTRSBCH UTRSACH 00 A, Terminal, SM Hub Open, OH 00 A, Terminal, SM Hub Open, OH/UG 00 A, Terminal, Solid Top, UG, Offset Ground connection. Lever bypass. Note: 00 CH catalog numbers are specialty sockets for individual utilities and do not follow typical catalog numbering system. TABLE. CUTLER-HAMMER METER SOCKET ACCESSORIES #8 0 kcmil #8 0 kcmil #8 0 kcmil #8 0 kcmil #8 0 kcmil #8 0 kcmil 0 Ampere Commercial Residential w/ Lever Bypass 0097CH 0 A, Terminal, LG Hub Cover Plate, OH/UG Dual Dual 00 Ampere Single-Position Commercial w/ Lever Bypass UTHB or TCH UTH7B or TCH 00 A, Terminal, SM or LG Hub Open, OH/UG A, 7 Terminal, SM or LG Hub Open, OH/UG Ampere Multi-Position Sockets Residential UTRBCH UTRBCH UTRBCH UTRBCH UT6RBCH 00 A, Position, SM Hub Open, OH/UG, Ctr Fed 00 A, Position, SM Hub Open, OH/UG, Ctr Fed 00 A, Position, SM Hub Open, OH/UG, Ctr Fed 00 A, Position, SM Hub Open, OH/UG, Ctr Fed 00 A, 6 Position, SM Hub Open, OH/UG, Ctr Fed 00 Ampere Multi-Position Sockets Residential UTRTCH UTRTCH UTRTCH UTR9TTCH UT6R9TTCH 00 A, Position, LG Hub Open, OH/UG, Ctr Fed 00 A, Position, LG Hub Open, OH/UG, Ctr Fed 00 A, Position, LG Hub Open, OH/UG, Ctr Fed 00 A, Position, LG Hub Open, OH/UG, Ctr Fed 00 A, 6 Position, LG Hub Open, OH/UG, Ctr Fed #6 0 kcmil #6 0 kcmil #6 0 kcmil #6 0 kcmil /0 00 kcmil /0 00 kcmil /0 00 kcmil #8 /0 #8 /0 #8 /0 #8 /0 #8 /0 #8 0 kcmil #8 0 kcmil #8 0 kcmil #8 0 kcmil #8 0 kcmil CUTLER-HAMMER CUTLER-HAMMER ARP0000CH ARP0000CH ARP0000CH ARP00006CH ARP00007CH.00-Inch Hub Small Opening.-Inch Hub Small Opening -Inch Hub Small Opening.00-Inch Hub Small Opening -Inch Hub Small Opening ARP00008CH ARP0006CHB ARP000CHAP ARP000CHJ ARP0009CH Small Hub Closure Plate Aluminum Large Hub Closure Plate Hub Adapter Plate Large to Small Replacement Plug-in Fifth Terminal (R and RS Models Only) Replacement Block Assembly for 00 A Sockets /0 Maximum ARP0007CH ARP0008CH ARP0009CH ARP000CH ARP0000CHB.00-Inch Hub Large Opening -Inch Hub Large Opening -Inch Hub Large Opening.00-Inch Hub Large Opening Small Hub Closure Plate ARP0008CH ARP00CH ARP009CH ARP007CH ARP009CH Replacement Block Assembly for 00 A Sockets 0 Maximum Replacement Block Assembly for 0 A Sockets 0 Maximum # kcmil Lug Dual Lug Lug EATON CORPORATION Cutler-Hammer Illinois and Northwest Indiana Metering Equipment Technical Focus TD00000E Copyright 007

7 Product Selection by Utility Commonwealth Edison 00 Ampere Single-Position Meter Socket (00766CH) Instrument Rated Meter Socket Terminal (USTHACH) 00 Ampere Single-Position Meter Socket (0098CH) 00 Ampere Multi-Position Meter Socket (008960CH) TABLE 6. COMMONWEALTH EDISON APPROVED METER SOCKETS DIMENSIONS IN INCHES CUTLER- HAMMER CATALOG BY- DIMENSIONS CONNECTIONS NUMBER TERMINALS HUB PASS TH JAW H W D LINE LOAD 00 & 00 Ampere Overhead Single Meter Sockets Single-Phase V 00766CH CH /00 A, Ground Connector Included 00 A, Ground Connector Included SM Opening SM Opening Hub sold separately. See Page 8, Table 8. For BR breakers, see Page, Table 9. " pedestal raceway 0088CH, 8" raceway extension 00968CH. Field kit ordered separately. Field reversible incoming lugs for OH or UG applications. One kit per socket. Note: 00 CH catalog numbers are specialty sockets for individual utilities and do not follow typical catalog numbering system. Lever ARP000CHJ #8 0 kcmil #8 0 kcmil #8 0 kcmil #8 0 kcmil 0 Ampere Overhead/Underground Single Meter Sockets Single-Phase V 00767CH 0 A, OH/UG, Ground Connector Included LG Opening Lever ARP006CH /8" Stud /8" Stud 00 Ampere Overhead Single Meter Socket -Phase V CH 00 A, Ground Connector Included 7 LG Opening Lever & 00 Ampere Overhead Combination Meter Breaker Single Sockets Single-Phase 0 V CH 00908CH 0098CH 0098CH 00 A with Provision for BR00 Main Breaker 00 A with BR Type Main Breaker Installed 00 A with CC Type Main Breaker Installed 00 A with CC Type Main Breaker Installed with Circuit BR Provision 00 Ampere Multi-Position Horizontal Meter Sockets 00969CH 00969CH 00969CH CH CH Gang OH/UG Gang OH/UG Gang OH/UG Gang OH/UG 6 Gang OH/UG 00 Ampere Multi-Position Horizontal Meter Sockets 0088CH Gang with Raceway Pedestal Opening 0088CH Gang with Raceway Pedestal Opening 0088CH Gang with Raceway Pedestal Opening 00979CH Gang with Raceway Pedestal Opening 0096CH 6 Gang with Raceway Pedestal Opening 00 Ampere Multiple Horizontal Sockets 00898CH 00899CH CH 0099CH 00996CH Gang Gang Gang Gang 6 Gang SM Opening SM Opening SM Opening SM Opening SM Cover Plate () SM Cover Plate () SM Cover Plate () SM Cover Plate () SM Cover Plate () LG Cover Plate LG Cover Plate LG Cover Plate LG Cover Plate () LG Cover Plate () LG Cover Plate LG Cover Plate LG Cover Plate LG Cover Plate LG Cover Plate ARP000CHJ ARP000CHJ ARP000CHJ ARP000CHJ ARP000CHJ ARP000CHJ ARP000CHJ ARP000CHJ ARP000CHJ ARP000CHJ ARP000CHJ ARP000CHJ ARP000CHJ ARP000CHJ ARP000CHJ #8 /0 #8 /0 #6 0 kcmil #6 0 kcmil #6 0 kcmil #6 0 kcmil #6 0 kcmil /0 00 kcmil /0 00 kcmil /0 00 kcmil /0 00 kcmil /0 00 kcmil /0 00 kcmil /0 00 kcmil /0 00 kcmil #8 /0 #8 /0 #8 /0 #8 /0 #8 /0 #8 /0 #8 /0 #8 0 kcmil #8 0 kcmil #8 0 kcmil #8 0 kcmil #8 0 kcmil #8 0 kcmil #8 0 kcmil #8 0 kcmil #8 0 kcmil #8 0 kcmil 6 EATON CORPORATION Cutler-Hammer Illinois and Northwest Indiana Metering Equipment Technical Focus TD00000E July 007

8 00 Ampere Single-Position Pedestal Meter Socket (00688CH) 00 Ampere Two-Position Pedestal Meter Socket (0096CH) 00 Ampere Meter Breaker Pedestal (009078CH) 0 Ampere Meter Breaker Pedestal (00887CH) TABLE 6. COMMONWEALTH EDISON APPROVED METER SOCKETS DIMENSIONS IN INCHES (CONTINUED) CUTLER- HAMMER CATALOG BY- DIMENSIONS CONNECTIONS NUMBER TERMINALS HUB PASS TH JAW H W D LINE LOAD Pedestals 00688CH CH CH 0096CH CH CH 00888CH 0090CH 00906CH 00/00 Ampere Pedestal 8" Pedestal Extension 0" Pedestal Extension -Position 00 Ampere Meter Sockets (Vertical) 8" Pedestal Extension 0" Pedestal Extension 0 Ampere Pedestal 8" Pedestal Extension 0" Pedestal Extension Hub sold separately. Field kit ordered separately. Solid Top ARP008CH /0 Compression #6 0 kcmil Solid Top /0 Compression Solid Top Lever /8" Studs Dual 0098CH -Phase 0 Ampere Pedestal 7 Solid Top Lever Meter Breaker Combo Pedestals 00886CH 0090CH 0090CH CH 0090CH 0090CH 00887CH 0090CH 0090CH 00 Ampere Pedestal with Breaker (BWH Type Disconnect Installed kaic) Circuit BR Provision 8" Pedestal Extension 0" Pedestal Extension 00 Ampere Pedestal with Breaker (BR Type Disconnect Installed 0 kaic) 8" Pedestal Extension 0" Pedestal Extension 0 Ampere with 00 A CC Type Breakers 8" Pedestal Extension 0" Pedestal Extension Instrument Rated Meter Sockets USTH6A9CH 6 Terminal Transformer Rated Socket Single-Phase, -Wire USTH8A9CH 8 Terminal Transformer Rated Socket -Phase, -Wire USTHACH Terminal Transformer Rated Socket -Phase, -Wire Solid Top Solid Top Solid Top Lever /8" Stud 6 8 Solid Top Solid Top Solid Top Note: 00 CH catalog numbers are specialty sockets for individual utilities and do not follow typical catalog numbering system EATON CORPORATION Cutler-Hammer Illinois and Northwest Indiana Metering Equipment Technical Focus TD00000E Copyright 007 7

9 Product Selection by Utility Commonwealth Edison (Continued) TABLE 7. CONCENTRIC KNOCKOUTS FOR COMMONWEALTH EDISON PAGE 6 AND 7, TABLE 6 CUTLER-HAMMER CONCENTRIC KNOCKOUTS CUTLER-HAMMER CONCENTRIC KNOCKOUTS 00 & 00 Ampere Overhead Single Meter Sockets Single-Phase V 00 Ampere Multiple Horizontal Sockets 00766CH CH 0 Ampere Overhead/Underground Single Meter Sockets Single-Phase V 00767CH 00 A Overhead Single Meter Socket -Phase V CH 00 & 00 Ampere Overhead Combination Meter Breaker Single Sockets Single-Phase 0 V CH 00908CH 0098CH 0098CH 00 Ampere Multi-Position Horizontal Meter Sockets 00969CH 00969CH 00969CH CH CH 00 Ampere Multi-Position Horizontal Meter Sockets 0088CH 0088CH 0088CH 00979CH 0096CH CH 00899CH CH 0099CH 00996CH Pedestals 00688CH CH CH 0096CH CH CH 00888CH 0090CH 00906CH 0098CH Meter Breaker Combo Pedestals 00886CH 0090CH 0090CH CH 0090CH 0090CH 00887CH 0090CH 0090CH Instrument Rated Meter Sockets USTH6A9CH USTH8A9CH USTHACH TABLE 8. CUTLER-HAMMER METER SOCKET ACCESSORIES CUTLER-HAMMER CUTLER-HAMMER ARP0000CH ARP0000CH ARP0000CH ARP00006CH ARP00007CH.00-Inch Hub Small Opening.-Inch Hub Small Opening -Inch Hub Small Opening.00-Inch Hub Small Opening -Inch Hub Small Opening ARP0006CHB ARP000CHAP ARP000CHJ ARP0009CH ARP0008CH Large Hub Closure Plate Hub Adapter Plate Large to Small Replacement Plug-in Fifth Terminal (R and RS Models Only) Replacement Block Assembly for 00 A Sockets /0 Maximum Replacement Block Assembly for 00 A Sockets 0 Maximum ARP0007CH ARP0008CH ARP0009CH ARP000CH ARP0000CHB ARP00008CH.00-Inch Hub Large Opening -Inch Hub Large Opening -Inch Hub Large Opening.00-Inch Hub Large Opening Small Hub Closure Plate Small Hub Closure Plate Aluminum ARP00CH ARP009CH ARP007CH ARP009CH CH CH Replacement Block Assembly for 0 A Sockets 0 Maximum # kcmil Lug Dual Lug Lug 8.00-Inch Pedestal Extension (8.00" H 8.97" W.9" D) 0.00-Inch Pedestal Extension (0.00" H 8.97" W.9" D) Note: See Page for BR and BWH type breaker offering. Note: 00 CH catalog numbers are specialty sockets for individual utilities and do not follow typical catalog numbering system. 8 EATON CORPORATION Cutler-Hammer Illinois and Northwest Indiana Metering Equipment Technical Focus TD00000E July 007

10 Technical Data Knockout Drawings 00887CH CH 00886CH 0096CH 00688CH 00888CH FIGURE. KNOCKOUT DRAWINGS DRAWINGS NOT TO SCALE EATON CORPORATION Cutler-Hammer Illinois and Northwest Indiana Metering Equipment Technical Focus TD00000E Copyright 007 9

11 Product Selection by Utility Ameren IP (Illinois Power Utility) 00 Ampere Single-Position Offset Meter Socket (UHTTRSACH) 0 Ampere Lever Bypass Meter Socket (UTTH0TCH) 00 Ampere Lever Bypass Meter Socket (UTH7TCH) 00 Ampere Multi-Position Meter Socket (UHTTRTCH) TABLE 9. AMEREN IP (ILLINOIS POWER) APPROVED METER SOCKETS DIMENSIONS IN INCHES CUTLER-HAMMER CATALOG NUMBER DIMENSIONS CONNECTIONS CONCENTRIC KNOCKOUTS (SEE PAGE 8) H W D LINE LOAD 00 Ampere Single-Position Residential UHTTRS0BCH A, Terminal, SM Hub Open, OH/UG #8 /0 #8 / Ampere Single-Position Residential UHTTRS0BCH UHTTRSACH UHTTRSBCH 00 A, Terminal, SM Hub Open, OH 00 A, Terminal, Solid Top, UG 00 A, Terminal, SM Hub Open, OH/UG Quad plex ground connection. bypass. Lever bypass. Ground connection #8 0 kcmil #8 0 kcmil #8 0 kcmil #8 0 kcmil #8 0 kcmil #8 0 kcmil 0 Ampere Commercial Residential w/ Lever Bypass UTTH0TCH 0 A, Terminal, LG Hub Open, OH/UG /8" Stud /8" Stud 00 Ampere Single-Position Commercial w/ Lever Bypass UTHB or TCH UTH7B or TCH 00 A, Terminal, SM or LG Hub Open, OH/UG A, 7 Terminal, SM or LG Hub Open, OH/UG Ampere Multi-Position Sockets Residential UHTTRBCH UHTTRBCH UHTTRBCH UHTTRBCH UHTT6RBCH 00 A, Position, SM Hub Open, OH/UG, Ctr Fed 00 A, Position, SM Hub Open, OH/UG, Ctr Fed 00 A, Position, SM Hub Open, OH/UG, Ctr Fed 00 A, Position, SM Hub Open, OH/UG, Ctr Fed 00 A, 6 Position, SM Hub Open, OH/UG, Ctr Fed 00 Ampere Multi-Position Sockets Residential UHTTRTCH UHTTRTCH UHTTRTCH UHTTR9TTCH UHTT6R9TTCH 00 A, Position, LG Hub Open, OH/UG, Ctr Fed 00 A, Position, LG Hub Open, OH/UG, Ctr Fed 00 A, Position, LG Hub Open, OH/UG, Ctr Fed 00 A, Position, LG Hub Open, OH/UG, Ctr Fed 00 A, 6 Position, LG Hub Open, OH/UG, Ctr Fed 00 Ampere Single-Position Sockets Residential & Commercial CH86K CH8K7 00 A, Terminal, LG Closure Plate, OH/UG 00 A, 7 Terminal, LG Closure Plate, OH/UG #6 0 kcmil #6 0 kcmil #6 0 kcmil #6 0 kcmil /0 00 kcmil /0 00 kcmil /0 00 kcmil /8 Stud /8 Stud #8 /0 #8 /0 #8 /0 #8 /0 #8 /0 #8 0 kcmil #8 0 kcmil #8 0 kcmil #8 0 kcmil #8 0 kcmil /8 Stud /8 Stud TABLE 0. CUTLER-HAMMER METER SOCKET ACCESSORIES CUTLER-HAMMER CUTLER-HAMMER ARP0000CH ARP0000CH ARP0000CH ARP00006CH ARP00007CH.00-Inch Hub Small Opening.-Inch Hub Small Opening -Inch Hub Small Opening.00-Inch Hub Small Opening -Inch Hub Small Opening ARP00008CH ARP0006CHB ARP000CHAP ARP000CHJ ARP0009CH Small Hub Closure Plate Aluminum Large Hub Closure Plate Hub Adapter Plate Large to Small Replacement Plug-in Fifth Terminal (R and RS Models Only) Replacement Block Assembly for 00 A Sockets /0 Maximum ARP0007CH ARP0008CH ARP0009CH ARP000CH ARP0000CHB.00-Inch Hub Large Opening -Inch Hub Large Opening -Inch Hub Large Opening.00-Inch Hub Large Opening Small Hub Closure Plate ARP0008CH ARP00CH ARP009CH ARP007CH ARP009CH Replacement Block Assembly for 00 A Sockets 0 Maximum Replacement Block Assembly for 0 A Sockets 0 Maximum # kcmil Lug Dual Lug Lug 0 EATON CORPORATION Cutler-Hammer Illinois and Northwest Indiana Metering Equipment Technical Focus TD00000E July 007

12 Northern Indiana Public Service Company NIPSCO 00 Ampere Single-Position Meter Socket (UHTRSBCH) 00 Ampere Lever Bypass Meter Socket (UTH7TCH) TABLE. NIPSCO APPROVED METER SOCKETS DIMENSIONS IN INCHES CUTLER-HAMMER CATALOG NUMBER Ground connection. bypass. Lever bypass. Anti-inversion clip factory installed. Quad plex ground connection. Note: 00 CH catalog numbers are specialty sockets for individual utilities and do not follow typical catalog numbering system. Note: Please reference Table 0 on Page 0 for Cutler-Hammer Meter Socket Accessories. DIMENSIONS CONNECTIONS CONCENTRIC KNOCKOUTS (SEE PAGE 8) H W D LINE LOAD 00 Ampere Single-Position Residential UHTRS0BCH A, Terminal, SM Hub Open, OH #8 /0 #8 / Ampere Single-Position Residential UHTRS0BCH UHTRSBCH 00766CH 00688CH 00 A, Terminal, SM Hub Open, OH 00 A, Terminal, SM Hub Open, UG 00 A, Terminal, SM Hub Open, OH 00 A, Terminal, Solid Top, UG, Pedestal 0 Ampere Commercial Residential w/ Lever Bypass 0089CH 00767CH A, Terminal, LG Hub Open, OH/UG A, Terminal, LG Hub Open, OH/UG Ampere Single-Position Commercial w/ Lever Bypass UTH0B or TCH UTHB or TCH UTH70B or TCH UTH7B or TCH CH CH 00 A, Terminal, SM or LG Hub Open, OH 00 A, Terminal, SM or LG Hub Open, OH/UG 00 A, 7 Terminal, SM or LG Hub Open, OH 00 A, 7 Terminal, SM or LG Hub Open, OH/UG 00 A, Terminal, SM or LG Hub Open, OH 00 A, 7 Terminal, SM or LG Hub Open, OH/UG Ampere Multi-Position Residential Single-Phase UHTRCCH UHTRCCH UHTRCCH UHTRCCH UHT6RCCH A, Position, SM Hub Closure Plate, OH/UG, End Feed A, Position, SM Hub Closure Plate, OH/UG, End Feed A, Position, SM Hub Closure Plate, OH/UG, End Feed A, Position, SM Hub Closure Plate, OH/UG, End Feed A, 6 Position, SM Hub Closure Plate, OH/UG, End Feed 00 Ampere Multi-Position Residential Single-Phase UHTRTCH UHTRTCH UHTRTCH UHTR9TTCH UHT6R9TTCH 00 A, Position, LG Hub Open, OH/UG, Ctr Fed 00 A, Position, LG Hub Open, OH/UG, Ctr Fed 00 A, Position, LG Hub Open, OH/UG, Ctr Fed 00 A, Position, LG Hub Open, OH/UG, Ctr Fed 00 A, 6 Position, LG Hub Open, OH/UG, Ctr Fed #8 0 kcmil #8 0 kcmil #8 0 kcmil /0 Compression /8" Stud /8" Stud #6 0 kcmil #6 0 kcmil #6 0 kcmil #6 0 kcmil #6 0 kcmil /0 00 kcmil /0 00 kcmil /0 00 kcmil #8 0 kcmil #8 0 kcmil #8 0 kcmil #6 0 kcmil /8" Stud /8" Stud #8 /0 #8 /0 #8 /0 #8 /0 #8 /0 #8 0 kcmil #8 0 kcmil #8 0 kcmil #8 0 kcmil #8 0 kcmil EATON CORPORATION Cutler-Hammer Illinois and Northwest Indiana Metering Equipment Technical Focus TD00000E Copyright 007

13 Meter Packs Product Description Product Selection TABLE. METER PACK ING SYSTEM M P R C T -Phase Trough Opening Meter Pack (MPRRLBT and 0089CH) Eaton s Cutler-Hammer MP units are self-contained (main terminal box included) for installations requiring up to six meter socket positions in a single enclosure. Units are not gangable with any other metering device. Approved by major power companies, UL listed, suitable as service equipment and meets the service and electrical requirements of EUSERC and CECHA. Series rating up to 00 kaic. All ringless cover devices include fifth jaw as standard. Ring type devices do not include fifth jaw as standard. Order MMJK if needed. Bondable neutral. 0/0 Vac, single-phase, -wire metering device. Up to amperes maximum horizontal bus rating. Incoming lugs not included (phase A, phase B, and neutral). Indoor/outdoor construction. Provision for -pole breaker (plug-on type for ampere sockets and bolt-on type for 00 ampere sockets) circuit breakers not included. Underground incoming feed. Aluminum or copper bus. When Ordering:. Determine catalog number of the basic device.. Include Lug Kit for incoming section. See Table 6.. Find quantity and catalog numbers for tenant circuit breakers. (Order one breaker per socket.) See Page.. Select required accessories. See Page 7. TABLE. METER PACKS ALUMINUM BUS SOCKET AMPERE RATING Metering Type MP = Meter Pack NUMBER OF METER SOCKETS BUS AMPERE RATING Ringless Style Meter Socket Covers Ringless Style Covers with Bypass Number of Meters,,, or 6 Blank = Accessory See Table 9. Fifth jaw factory installed at 9 o clock position. Main lugs included. #6 00 kcmil. (Optional lugs are not available.) Ampere Rating = Amperes 0 = 00 Amperes Blank = Accessory Bus Ampere Rating = 00 Amperes = 00 Amperes 6 = Amperes Blank = Accessory MAIN TENANT BREAKER TYPE Plug-on Type BR_ BRH_ BRHH_ Bolt-on Type CC_X CHH_HX CHH_HX CHH_X Plug-on Type Plug-on Type BR_ BRH_ BRHH_ Bolt-on Type CC_X CHH_HX CHH_HX CHH_X Bottom feed only. Line side lugs also included in these units. See Table 8. CECHA approved. Bus Material C = Copper Bus Blank = Aluminum Bus KNOCKOUT OPENINGS MPRRL MPRRL MPRRL MP6RRL MP66RRL MP0RRL MP06RRL MP06RRL MP06RRL MP606RRL Note: See Table 6 for Main Lug Kit Selection. See Table 7 for Wire Sizes. Security or Accessory Code R = Ring RRL = Ringless RRLB = Ringless with Bypass LK = Lug Kit (Accessory) SC = Crimp Lug Landing Pad Kit (Accessory) TROUGH OPENING MPRRLB MPRRLBEXT MPRRLB MPRRLB MP6RRLB MP66RRLB MP0RRLB MP06RRLB MP06RRLB MP06RRLB MP606RRLB MPRRLBT MPRRLBT MP6RRLBT MP66RRLBT MP0RRLBT MP06RRLBT MP06RRLBT MP06RRLBT MP606RRLBT SEMI-FLUSH FLANGE KIT MPSFK MPSFK MPSFK MPSFK MPSFK MPSFK MPSFK MPSFK MPSFK6 MPSFK6 MPSFK MPSFK MPSFK MPSFK MPSFK MPSFK MPSFK MPSFK MPSFK MPSFK6 MPSFK6 Built at Lincoln Flex Center. Trough included. Lugs included. See Table 8 for lug sizes. EATON CORPORATION Cutler-Hammer Illinois and Northwest Indiana Metering Equipment Technical Focus TD00000E July 007

14 Meter Packs TABLE. METER PACKS COPPER BUS SOCKET AMPERE RATING NUMBER OF METER SOCKETS BUS AMPERE RATING MAIN TENANT BREAKER TYPE CATALOG NUMBER SEMI-FLUSH FLANGE KIT Ringless Style Meter Socket Covers Plug-on Type BR_ BRH_ BRHH_ Bolt-on Type CC_X CHH_HX CHH_HX CHH_X MPRRLC MPRRLC MP6RRLC MP66RRLC MP0RRLC MP06RRLC MP06RRLC MP06RRLC MP606RRLC MPSFK MPSFK MPSFK MPSFK MPSFK MPSFK MPSFK MPSFK6 MPSFK6 Ringless Style Covers with Bypass Plug-on Type BR_ BRH_ BRHH_ Bolt-on Type CC_X CHH_HX CHH_HX CHH_X MPRRLBC MPRRLBC MP6RRLBC MP66RRLBC MP0RRLBC MP06RRLBC MP06RRLBC MP06RRLBC MP606RRLBC MPSFK MPSFK MPSFK MPSFK MPSFK MPSFK MPSFK MPSFK6 MPSFK6 See Table 9. Fifth jaw factory installed at 9 o clock position. CECHA approved. TABLE. CECHA APPROVED METER SOCKET ACCESSORIES Pedestal Trough Raceway for Underground Services 6.00-Inch Pedestal Trough Raceway (6.00" H 9.00" W." D) 8.00-Inch Pedestal Extension For use with meter packs with T trough provision. TABLE 6. MAIN LUG KIT SELECTION FIELD INSTALLED KITS FOR EITHER 00 OR AMPERE MAIN BUS LINE LUG AND WIRE SIZES ORDER SEPARATELY AND FIELD INSTALL () #6 kcmil or () /0 0 kcmil () 0 00 kcmil () # 00 kcmil () 70 kcmil Crimp lug landing pad 0 70 kcmil CATALOG NUMBER 0089CH CH LINE LUG KIT ORDER THREE KITS (FOR TWO LINES AND NEUTRAL) MPLK MPLK MPLK MPLK MPSC This lug is not UL listed. This kit comes with three pads for two lines and neutral. Each pad will accept one or two crimp lugs. Cannot be used on MPR, RL and RLB EUSERC underground termination. TABLE 7. WIRE SIZES NEUTRAL AND GROUND LUGS Neutral: ampere meter pack 00 ampere meter pack Equipment Ground Bar: ampere meter pack 00 ampere meter pack WIRE SIZE, AL/CU #6 /0 #/0 00 kcmil # # # /0 Note: Each stack includes a neutral and ground bar. If an extra ground bar is needed, order MMGBK. TABLE 8. METER PACK WITH TROUGH LUGS CATALOG NUMBER Optional Ground Bar #6 /0 MMGBK CATALOG NUMBER () #6-0 kcmil Hole and () /0 kcmil or () /0 0 kcmil Hole MPRRLBT () #6-0 kcmil Hole and () /0 kcmil or () /0 0 kcmil Hole MPRRLBT () 0 00 kcmil Holes () 0 00 kcmil Holes () 0 00 kcmil Holes () 0 00 kcmil Holes () 0 00 kcmil Holes () 0 00 kcmil Holes () 0 00 kcmil Holes MP6RRLBT MP66RRLBT MP0RRLBT MP06RRLBT MP06RRLBT MP06RRLBT MP606RRLBT Note: Lugs are included in meter packs with the trough one lug per phase. EATON CORPORATION Cutler-Hammer Illinois and Northwest Indiana Metering Equipment Technical Focus TD00000E Copyright 007

15 Group Metering Main Tenant and Pedestal Circuit Breakers Product Description MP, MM and MM Main Tenant and Pedestal Circuit Breakers The following Cutler-Hammer breakers are to be used on MP and combination meter breaker units. They are 0/0 Vac field installed. BR00 CC00 BWH00 Product Selection TABLE 9. MP, MM AND MM MAIN TENANT AND PEDESTAL CIRCUIT BREAKERS NUMBER OF POLES MAIN TENANT CIRCUIT BREAKER AMPERE RATING 0,000 AIC,000 AIC,000 AIC,000 AIC 00,000 AIC Plug-on type circuit breakers used with MP, MM and MM ampere modular metering stacks Bolt-on type circuit breakers used with MP, MM and MM 00 ampere modular metering stacks BR60 BR70 BR80 BR90 BR00 BR0 BR CC00X CCX CC0X CC7X CC00X BRH60 BRH70 BRH80 BRH90 BRH00 BRH0 BRH CHH060HX CHH070HX CHH080HX CHH090HX CHH00HX CHHHX CHH0HX CHH7HX CHH00HX BRHH60 BRHH70 BRHH80 BRHH90 BRHH00 BRHH0 BRHH CHH060HX CHH070HX CHH080HX CHH090HX CHH00HX CHHHX CHH0HX CHH7HX CHH00HX CHH060X CHH070X CHH080X CHH090X CHH00X CHHX CHH0X CHH7X CHH00X Note: For the 00887CH, order CC 0 kaic breakers. Omit the X suffix. TABLE 0. MAIN BREAKER SELECTION CHART MAXIMUM AMPERE RATING POLE BREAKER 0 KAIC KAIC BW00 BW BW0 BW00 BWH00 BWH BWH0 BWH00 Load Side Lug Kit for BW Breakers MCBK For use with 00886CH. When a provision for main is provided, order one of the main breakers listed in this table. All panels are dual labeled to accept Types BW and BWH Main Breakers. EATON CORPORATION Cutler-Hammer Illinois and Northwest Indiana Metering Equipment Technical Focus TD00000E July 007

16 Meter Packs Dimensions and Knockouts (in Inches) MP Meter Packs Aluminum and Copper Bus To C L of Wall Mtg. Screw.699 Meter To CL Rail Mtg. Screw CL 7.0 () Knockout for, -/, -/ Conduit Concentric Knockouts ", -/", -/", Knockout Concentric Knockouts -/", ", -/", " Knockout () Knockout for -/,, -/ Conduit Concentric Knockouts /" Knockout , Meter Device.0 Concentric Knockouts -/", ", -/", " Knockout.69.0, 6 Meter Device Concentric Knockouts ", -/", -/", Knockout Concentric Knockouts /" Knockout "Z" "Y""X".0 "W" (6.6) (76.) "W" "X" "Y" "Z" "Z" = CL of /" Ring "Y" = CL of -/" Ring "X" = CL of -/" Ring "W" = CL of " Ring Mtn. for, -/, " C-H Conduit Hubs /", ", -/", " Knockouts /" Knockout.87 ", -/", -/" Knockouts (6 Required) Mtg Holes Places, -/, -/" KO 6 Places Dia. Hub Opening Bottom Endwall Knockouts for Units with "T" Suffix, Meter Device.06 Top View Bottom Endwall Knockouts for Units with "T" Suffix, 6 Meter Device Ampere Meter Packs FIGURE. AMPERE MAXIMUM TENANT BREAKER EATON CORPORATION Cutler-Hammer Illinois and Northwest Indiana Metering Equipment Technical Focus TD00000E Copyright 007

17 Group Metering Meter Packs Dimensions and Knockouts (in Inches) MP Meter Packs Aluminum and Copper Bus Meter Device To C L of Wall Mtg. Screw Meter To CL Rail Mtg. Screw CL () Knock Out For ", -/", -/", " Conduit.. Concentric Knockouts Concentric Knockouts /" Knockout ", -/", -/", " Knockout Concentric Knockouts -/", ", -/", " Knockout "W" "Z" "Y""X".0, & Meter Endwall, Meter Device Typ , 6 Meter Device "Z" = CL of /" Ring "Y" = CL of -/" Ring "X" = CL of -/" Ring "W" = CL of " Ring Concentric Knockouts -/", ", -/", " Knockout.69 Concentric Knockouts ", -/", -/", " Knockout Concentric Knockouts /" Knockout "X" "W" "Y" "Z" Bottom Endwall Knockouts for Units with "T" Suffix,, Meter Device Bottom Endwall Knockouts for Units with "T" Suffix, 6 Meter Device 00 Ampere Meter Packs FIGURE. 00 AMPERE MAXIMUM TENANT BREAKER 6 EATON CORPORATION Cutler-Hammer Illinois and Northwest Indiana Metering Equipment Technical Focus TD00000E July 007

18 Accessories Meter Packs TABLE. ACCESSORIES FOR MP METERING STACKS APPLICATION CATALOG NUMBER Fifth Jaw Kit Bolted onto neutral in the, 6 or 9 o clock position. MMJK Typically used on network metering systems (-phase in/single-phase out) or when specified by utility company. Isolated Fifth Jaw Kit Connects to the neutral with an insolated wire. MMJKOP Bypass Used only on ringless cover stacks, kits can be installed on ampere or 00 ampere sockets. Note: For MPRRL use: MMBPH WCG8HB Meter Bypass Jumper Installed on ampere or 00 ampere sockets. MMBPJ Jumpers are plugged into jaws. Order Lexan cover plate with bypass jumpers to prevent access to meter socket once energized. (Not UL listed.) Lexan Blank Cover Circular cover mounted on ring or ringless devices MMPCP preventing access to meter socket while meter is not in place. Includes plastic tabs which plug into each jaw. Same as MMPCP minus the tabs located in the back to plug into jaws. MMACP This device to be used while meter bypass jumpers are in place (MMBPJ). Blank Meter Socket Cover Used for ampere stacks. Fits bottom socket only. MMBCB Kit replaces existing meter cover preventing access to meter socket. Includes hasp for seal. Used on 00 ampere stacks. Fits bottom socket only. MMBC00B Kit replaces existing meter cover preventing access to meter socket. Includes hasp for seal. Wall Mounting Rail Rails are feet (. m) in length. Bolted on wall for stacks, packs, and mains to be hung. MMWB Fifth Jaw Kit Bypass Kit Lexan Blank Cover Wall Mounting Rail INNER-TITE is a registered trademark of Inner- Tite Corp. Lexan is a registered trademark of General Electric Co., USA. UL is a registered trademark of Underwriters Laboratories Inc. EATON CORPORATION Cutler-Hammer Illinois and Northwest Indiana Metering Equipment Technical Focus TD00000E Copyright 007 7

19 Technical Data Knockout Drawings 00766CH CH CH, UTRTCH and UHTTRTCH 00898CH, UTRTCH and UHTTRTCH UTRSBCH and UHTTRSBCH 0088CH 00767CH, 0089CH and UTTH0TCH 00899CH, UTRTCH and UHTTRTCH UTRSACH and UHTTRSACH UTHTCH and UTH0TCH 0088CH FIGURE. KNOCKOUT DRAWINGS DRAWINGS NOT TO SCALE 8 EATON CORPORATION Cutler-Hammer Illinois and Northwest Indiana Metering Equipment Technical Focus TD00000E July 007

20 Knockout Drawings UTRTCH and UHTTRTCH 0088CH USTHACH UTR9TTCH and UHTTR9TTCH 00979CH 00969CH UT6R9TTCH and UHTT6R9TTCH 0096CH 00969CH 0098CH CH and 00908CH CH FIGURE. KNOCKOUT DRAWINGS DRAWINGS NOT TO SCALE EATON CORPORATION Cutler-Hammer Illinois and Northwest Indiana Metering Equipment Technical Focus TD00000E Copyright 007 9

21 Eaton Corporation Electrical Group 000 Cherrington Parkway Moon Township, PA 08 United States 877-ETN-CARE ( ) Eaton.com 007 Eaton Corporation All Rights Reserved Printed in USA Publication No. TD00000E/ Z9 July 007

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide. .2 Overview Product Selection Guide BR Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Short-Circuit Current Rating 0 kaic: All single- and three-phase loadcenters 70 225 A, 8 to 42

More information

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide. .2 Overview Product Selection Guide BR Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Short-Circuit Current Rating 0 kaic: All single- and three-phase loadcenters 70 225A, 8 to 42

More information

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide. .2 Loadcenters and Circuit Breakers Overview Product Selection Guide BR Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Short-Circuit Current Rating 0 kaic: All single- and three-phase

More information

Square D Meter Centers. A Comprehensive. Selection. Time-Saving, Reliable. Solutions

Square D Meter Centers. A Comprehensive. Selection. Time-Saving, Reliable. Solutions Square D Meter Centers A Comprehensive Selection of Time-Saving, Reliable Solutions VERSATILITY. DESIGN SUPERIORITY. SELECTION. Installation simplicity. The largest selection of meter centers in the industry.

More information

Self Contained - Non-Jaw Clamping Lever Bypass

Self Contained - Non-Jaw Clamping Lever Bypass Self Contained - Non-Jaw Clamping 125 Amp Continuous - 600 VAC Application Single meter position Designed for watt hour meters that meet ANSI C12.10 Overhead or underground feed Surface mount Construction

More information

Self Contained - Non Lever Bypass

Self Contained - Non Lever Bypass Self Contained - Non 125 & 200 Amp Continuous - 600 VAC Application Single meter position Designed for watt hour meters that meet ANSI C12.10 Overhead or underground feed Surface mount Construction Ringless

More information

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.

1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide. .2 Loadcenters and Circuit Breakers Overview Product Selection Guide BR Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Short-Circuit Current Rating 0 kaic: All single- and three-phase

More information

Meter Enclosure and Equipment Standards

Meter Enclosure and Equipment Standards Meter Enclosure and Equipment Standards (a) (b) General Requirements: CITY OF OCALA UTILITY SERVICES METER ENCLOSURE AND EQUIPMENT STANDARDS: (1) To avoid the costs associated with having to replace unacceptable

More information

MARWELL CORPORATION Manufacturer of UL Listed Meter Socket Adapters

MARWELL CORPORATION Manufacturer of UL Listed Meter Socket Adapters Yellow Section Capacitor Sockets and Monitors, Temporary Service Adapters, Quick Set/Gen Set, Temporary Load Center, TSA, Transformer Load Management CAPACITOR CONTROLLER SOCKET Four - Six Jaws Wire Lugs

More information

Residential Renovation Loadcenters and Accessories

Residential Renovation Loadcenters and Accessories Residential Renovation Loadcenters and Accessories Product Focus Replaces existing fuse boxes or loadcenters Industry Exclusive Renovation Loadcenter Quick and Clean Installation Designed specifically

More information

Meter Breakers. Technical Data. Contents

Meter Breakers. Technical Data. Contents Technical Data Effective: October Page ew Information Meter reakers Contents Description Page Residential Meter reakers Residential Meter reakers...................................... Product Selection..............................................,

More information

Section 20 Distribution (Underground)

Section 20 Distribution (Underground) PREVIOUS SEARCH NEXT Section Distribution (Underground) Table of Contents Page Underground Connectors...-2 Padmount Transformer Connectors...-3 Pedestal Connectors...-4 Pedestal Block Connector...-6 Street

More information

Power-Style QED-2, Series 2 Low Voltage Switchboards

Power-Style QED-2, Series 2 Low Voltage Switchboards Power-Style QED-2, Series 2 Low Voltage Switchboards Catalog 2742CT1001 (Addendum to 2742CT9501R12/09) 2010 Class 2742 CONTENTS Description............................................. Page Features...................................................

More information

Circuit Breakers NEED

Circuit Breakers NEED Type BR NEED Product Description The primary function of a circuit breaker is to protect the wire from overheating (referred to as an overload) and fault currents (referred to as short circuits). Circuit

More information

Modular Splicing FAX MODULAR SPLICING. Modular Splicing Kits 305 Cable Adapter Kits 308

Modular Splicing FAX MODULAR SPLICING. Modular Splicing Kits 305 Cable Adapter Kits 308 Modular Splicing Modular Splicing Kits 305 Cable Adapter Kits 308 MODULAR SPLICING 3M Modular Splice Kits form a 5 to 25 kv 600 Amp separable insulated connector system. The system is easy to expand and

More information

Power Mod. Introduction and Contents. Revised 02/18/14

Power Mod. Introduction and Contents. Revised 02/18/14 Introduction and Contents 02/18/14 2 METER Siemens Power Mod is a robust, flexible, and feature-rich line of modular metering designed to exceed today s market demands. Power Mod s exclusive QuickSystem

More information

Cooper B-Line RESIDENTIAL SERVICES

Cooper B-Line RESIDENTIAL SERVICES RESIDENTIAL SERVICES Approved Voltage Optional Voltage w/utility Approval 011 011 5 th Clip 100 Amp Socket Only, Overhead 011F 011F 5 th Clip 100 Amp Meter Socket & Circuit 1M1R 1M1R 5 th Clip Breaker

More information

Free-Stand Universal-Cutout Disconnects Type 12 Modular Free-Stand Disconnects and Accessories

Free-Stand Universal-Cutout Disconnects Type 12 Modular Free-Stand Disconnects and Accessories 763.422.2600 SPEC-00252 N763.422.2211 DISCONNECT FREE-STAND UNIVERSAL-CUTOUT DISCONNECTS TYPE 12 MODULAR FREE-STAND DISCONNECTS AND ACCESSORIES Free-Stand Universal-Cutout Disconnects Type 12 Modular Free-Stand

More information

SECTION PANELBOARDS

SECTION PANELBOARDS SECTION 16450 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for panelboards providing fault interrupting capability and overcurrent protective devices. 1.02 REFERENCE STANDARDS A.

More information

Specifications. S&C Regulator Bypass Switches Type XL (Sequenced) and Type NL (Nonsequenced) Outdoor Distribution (14.

Specifications. S&C Regulator Bypass Switches Type XL (Sequenced) and Type NL (Nonsequenced) Outdoor Distribution (14. Type XL (Sequenced) and Type NL (Nonsequenced) Outdoor Distribution (14.4 kv and 25 kv) Specifications Conditions of Sale STANDARD: The seller s standard conditions of sale set forth in Price Sheet 150

More information

Free-Stand Universal-Cutout Disconnects Type 12 Modular Free-Stand Disconnects and Accessories

Free-Stand Universal-Cutout Disconnects Type 12 Modular Free-Stand Disconnects and Accessories Spec-00252 Free-Stand Universal-Cutout Disconnects Type 12 Modular Free-Stand Disconnects and Accessories Modular Disconnect Enclosure, Type 12 INDUSTRY STANDARDS UL 508A Listed; Type 12; File No. E61997

More information

alid portable power cart epcc panel ccts EPCC-60 40" 60A, 120/208V 3PH 24 EPCC " 100A, 120/208V 3PH 24

alid portable power cart epcc  panel ccts EPCC-60 40 60A, 120/208V 3PH 24 EPCC  100A, 120/208V 3PH 24 portable power cart epcc Features/Specifications 12GA Steel construction CSA Type 3R rated Pin & Sleeve inlet connector Pad-lockable door Up to12 receptacles Cut-out in bottom to provide while-in-use Polyurethane,

More information

PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ)

PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ) PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ) Catalog Class 0CT00R/0 0 CONTENTS Description..............................................Page Description.............................................

More information

This Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount.

This Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount. This Datasheet for the IC697CHS790 Rack, 9 Slots, Rear Mount. http://www.cimtecautomation.com/parts/p-14771-ic697chs790.aspx Provides the wiring diagrams and installation guidelines for this GE Series

More information

Free-Stand Universal-Cutout Disconnects Type 12 Modular Free-Stand Disconnects and Accessories

Free-Stand Universal-Cutout Disconnects Type 12 Modular Free-Stand Disconnects and Accessories 763.422.2600 Spec-00252 L763.422.2211 Free-Stand Universal-Cutout s Type 12 Modular Free-Stand s and accessories Free-Stand Universal-Cutout s Type 12 Modular Free-Stand s and Accessories Modular Enclosure,

More information

ISOLATION RELAY RACK ISOLATION KIT 19 RACK MOUNT RELAY RACK ISOLATION KIT, SLOTTED UNEQUAL FLANGE RACK ISOLATION KIT 23 RACK MOUNT

ISOLATION RELAY RACK ISOLATION KIT 19 RACK MOUNT RELAY RACK ISOLATION KIT, SLOTTED UNEQUAL FLANGE RACK ISOLATION KIT 23 RACK MOUNT ISOLATION Info: 9070 = Isolation RELAY RACK ISOLATION KIT 19 RACK MOUNT 9070-1019 19" Rack Mount 23 RACK MOUNT 9070-1023 23" Rack Mount RELAY RACK ISOLATION (KIT) RELAY RACK ISOLATION KIT, SLOTTED 19 RACK

More information

HP404040SHL 400A PNL, 200A MCB W/40 Dist & Prov For 200A Main, 2

HP404040SHL 400A PNL, 200A MCB W/40 Dist & Prov For 200A Main, 2 0 South Street -, TX acogdoches Phone: -- Fax: -0- Catalog umber Manufacturer Description Weight per unit Product Category Features amperage rating dimensions interrupt rating main circuit breaker umber

More information

I-Line Panelboards. Innovative design, smart bus technology, and simple installation

I-Line Panelboards. Innovative design, smart bus technology, and simple installation I-Line Panelboards Innovative design, smart bus technology, and simple installation TM Smart: designed for efficient installation Simple: Efficient Installation Process I-Line Breakers Main Lugs: Fixed-mounted

More information

INTERNATIONAL MODULAR WIRING DEVICES

INTERNATIONAL MODULAR WIRING DEVICES INTERNATIONAL MODULAR WIRING DEVICES International Configurations Inc s product range of Country specific modular wiring devices are designed for Worldwide construction projects, data centers, medical

More information

CANADIAN CATALOG JANUARY SENTRICITY Loadcentres and Circuit Breakers Raising the standard in residential.

CANADIAN CATALOG JANUARY SENTRICITY Loadcentres and Circuit Breakers Raising the standard in residential. CANADIAN CATALOG JANUARY 208 Loadcentres and Circuit Breakers Raising the standard in residential. 2 S E N T R I C I T Y T M L O A D C E N T R E S A N D C I R C U I T B R E A K E R S - C A N A D I A N

More information

SECTION SWITCHBOARDS

SECTION SWITCHBOARDS SECTION 26 24 13 PART 1 - GENERAL 1.1 SUMMARY A. Work Included: 1. Switchboards 2. Commercial Metering Switchboards 3. Non-Utility Power Meters (Microprocessor-Based Metering Equipment) PART 2 - PRODUCTS

More information

PowerLogic High Density Metering System 1-Meter Enclosure

PowerLogic High Density Metering System 1-Meter Enclosure PowerLogic High Density Metering System 1-Meter Enclosure Installation Guide 63230-508-211A1 Safety information PowerLogic High Density Metering System 1-Meter Enclosure Important information Read these

More information

7" Touch Screen Display

7 Touch Screen Display 7" Touch Screen Display Installation Guide Contents Minimum Requirements...1 Select a Location...1 Initial Setup...2 Unboxing...2 Installation...3 Prepare the Panel...3 Install the Mounting Plate...3 Mount

More information

User s Guide. Includes Mounting, Installation, and Product Registration nd Avenue NE Arlington, WA USA (+1)

User s Guide. Includes Mounting, Installation, and Product Registration nd Avenue NE Arlington, WA USA (+1) User s Guide Includes Mounting, Installation, and Product Registration 500 19009 62nd Avenue NE Arlington, WA USA (+1) 360-435-6030 European Sales Office Barcelona, España (+34) 600-843-845 www.outbackpower.com

More information

US Catalog July 2016 SMISSLINE TP

US Catalog July 2016 SMISSLINE TP US Catalog July 2016 SMISSLINE TP SMISSLINE TP modular bus system Table of contents Description 2 Building a SMISSLINE TP assembly for UL 489 and UL 508 based solutions Overview and ordering information

More information

Time delay undervoltage module

Time delay undervoltage module Supersedes December 2010 Power Defense ICCB Series NRX IZMX Instructions apply to: UL489 IEC UL1066/ANSI : PD-NF, Series NRX NF : PD-NF, IZMX16 : Series NRX NF UL489 : PD-RF IEC : PD-RF, IZMX40 120VAC

More information

Power Supply Installation

Power Supply Installation Power Supply Module Overview, on page Installation Guidelines, on page 4 Installing or Replacing an AC Power Supply, on page 6 Installing a DC Power Supply, on page 7 Finding the Power Supply Module Serial

More information

US 5,634,357 D 385,7683 Bulletin: A21S4

US 5,634,357 D 385,7683 Bulletin: A21S4 763.422.2600 Spec-00384 H763.422.2211 Free-Stand Stainless Steel Preferred-Cutout s Stainless Steel Two-Door s Free-Stand Stainless Steel Preferred-Cutout s Stainless Steel Two-Door s Two-Door Stainless

More information

Posi-Lok Plugs and Panels

Posi-Lok Plugs and Panels THE SAFEST ELECTRICAL SYSTEM FOR HIGH AMPERAGE CONNECTIONS, POSI-LOK IS PART OF THE CAM-LOK FAMILY OF CONNECTORS. THE GROUND ALWAYS MAKES FIRST AND BREAKS LAST ALL POSI-LOK SYSTEMS ARE UL LISTED AND CSA

More information

ASCO 920 Remote Control (RC) Switches

ASCO 920 Remote Control (RC) Switches Maximum reliability and excellent value ASCO 920 Remote Control (RC) Switches ASCO 920 Remote Control Switch in Type Enclosure The ASCO 920 is designed as a feeder disconnect switch for load capacities

More information

Ground Power Modules. And Accessories For Healthcare Facilities. Technical Bulletin NAE /

Ground Power Modules. And Accessories For Healthcare Facilities. Technical Bulletin NAE / 2 Ground Power Modules And Accessories For Healthcare Facilities Technical Bulletin NAE2092320 / 10.2011 Ground Power Modules Hospital grade outlet modules Introduction BENDER series GPM ground and power

More information

Free-Stand Stainless Steel Preferred-Cutout Disconnects Stainless Steel Two-Door Disconnects US 5,634,357 D 385,7683 BULLETIN: A21S4

Free-Stand Stainless Steel Preferred-Cutout Disconnects Stainless Steel Two-Door Disconnects US 5,634,357 D 385,7683 BULLETIN: A21S4 763.422.2600 SPEC-00384 J763.422.2211 DISCONNECT FREE-STAND STAINLESS STEEL PREFERRED-CUTOUT DISCONNECTS STAINLESS STEEL TWO-DOOR DISCONNECTS Free-Stand Stainless Steel Preferred-Cutout Disconnects Stainless

More information

MICHIGAN DEPARTMENT OF TRANSPORTATION

MICHIGAN DEPARTMENT OF TRANSPORTATION MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR GROUNDING, BONDING, LIGHTNING PROTECTION AND SURGE PROTECTION FOR INTELLIGENT TRANSPORTATION SYSTEM EQUIPMENT ITS:CLC 1 of 5 APPR:LWB:DBP:07-31-13

More information

Model# CKM18 Model# CKM36 Model# CKM48 WARNING

Model# CKM18 Model# CKM36 Model# CKM48 WARNING Installation Instructions Model# CKM18 Model# CKM36 Model# CKM48 WARNING HAZARDOUS VOLTAGES. DISCONNECT FROM SUPPLY BEFORE REMOVING COVERS. NO USER SERVICEABLE PARTS INSIDE. SERVICE BY QUALIFIED PERSONNEL

More information

920 Remote Control (RC) Switches

920 Remote Control (RC) Switches 920 Remote Control (RC) Switches ASCO is the global leader in power switching and controls ASCO 920 PRODUCT SPECIFICATIONS SWITCH ONLY (PANELBOARD MOUNTING) 1,2,3 () DIMENSIONS, IN.(MM) WIDTH HEIGHT DEPTH

More information

MPS-Lite. A range of Blank and Connectorized panels in 3 standard widths to fit a 2RU / 3.50 vertical space, plus Adapters to accommodate them.

MPS-Lite. A range of Blank and Connectorized panels in 3 standard widths to fit a 2RU / 3.50 vertical space, plus Adapters to accommodate them. MPS-Lite A range of Blank and Connectorized panels in 3 standard widths to fit a 2RU / 3.50 vertical space, plus Adapters to accommodate them. A size panel (0.90 x 3.50 ) + more B Size panels (1.80 x 3.50

More information

Application Techniques CENTERLINE 2100 Motor Control Centers

Application Techniques CENTERLINE 2100 Motor Control Centers POWER SYSTEM CONSIDERATIONS FOR PRODUCT SELECTION Application Techniques CENTERLINE 2100 Motor Control Centers Power System Considerations for Product Selection i Power System Considerations for Product

More information

Type NT and Type ZWM Terminal Blocks

Type NT and Type ZWM Terminal Blocks Type NT and Type ZWM Terminal Blocks Unit-pole construction Sliding link to permit testing without disturbing wiring High barriers that prevent shorting between poles Class 1E qualified per IEEE RECOGNIZED

More information

NT-2300 Series Dual Circuit Track System & Accessories

NT-2300 Series Dual Circuit Track System & Accessories ILLUMINATING THE FUTURE...SINCE 1989 NT-2300 Series Dual Circuit Track System & Accessories Type Project Catalog No. Lamp/Wattage PRODUCT DESCRIPTION Low profile, extruded aluminum track with 20-Amp rated

More information

Meter Centers Modular Metering: Residential Modules

Meter Centers Modular Metering: Residential Modules Modular Metering: Residential Modules Residential Meter Modules 125A, 200A - 2 Gang Wiring Diagrams 2 WMM2U WMM2200U METER A11 WMM2U A16 WMM2200U WMM24AB200U WMM24BC200U WMM24CA200U Diagrams also applicable

More information

PLC Racks IC697CHS782/783

PLC Racks IC697CHS782/783 5 1 PLC Racks IC697CHS782/783 (IC697CHS782/783) datasheet Features Accepts 3rd Party VME modules which require 0.8 spacing. Accepts all IC697 PLC module types. Rear mount rack mounts in a 10 (254 mm) deep

More information

Free-Stand Universal-Cutout Disconnects Free-Stand Type 12 Disconnects

Free-Stand Universal-Cutout Disconnects Free-Stand Type 12 Disconnects 763.422.2600 SPEC-00250 N763.422.2211 DISCONNECT FREE-STAND UNIVERSAL-CUTOUT DISCONNECTS FREE-STAND TYPE 12 DISCONNECTS Free-Stand Universal-Cutout Disconnects Free-Stand Type 12 Disconnects TWO-DOOR WITH

More information

Dual-Feed 80A Auto Low Voltage Disconnect Panel - 80LVD02

Dual-Feed 80A Auto Low Voltage Disconnect Panel - 80LVD02 Dual-Feed 80A Auto Low Voltage Disconnect Panel - 80LVD02 User Manual 1.1 Overview Telect s 80A, -48 Vdc Low-Voltage Disconnect (LVD) panel is a rack-mounted component with coil-operated contactors. These

More information

Power Xpert Meter 2000 Gateway Card Kit

Power Xpert Meter 2000 Gateway Card Kit Quick Start Guide IL02601011E Rev. 2 December 2011 PXM 2250 PXM 2260 IQ 250 IQ 260 Power Xpert Meter 2000 Gateway Card Kit Table of Contents Remove the Meter From Service.... 2 Disconnect Power Connections,

More information

Power Xpert Meter 2000 Gateway Card Kit

Power Xpert Meter 2000 Gateway Card Kit Quick Start Guide IL02601011E PXM 2250 PXM 2260 IQ 250 IQ 260 Power Xpert Meter 2000 Gateway Card Kit Table of Contents Remove the Meter From Service... 2 Disconnect Power Connections, CTs, and Modbus....

More information

SINGLE BARREL 1/2 9/16 3/4 7/ /2 1/2 5/8 11/ /8 1 1 /4 1 9 / /4 SINGLE BARREL NEMA TANG DRILLING CTN /8 1 3 /16 CTN 71055

SINGLE BARREL 1/2 9/16 3/4 7/ /2 1/2 5/8 11/ /8 1 1 /4 1 9 / /4 SINGLE BARREL NEMA TANG DRILLING CTN /8 1 3 /16 CTN 71055 PAGE MECHANICAL LUGS ALUMINUM SAL SERIES AL OR CU DIMENSIONS (IN) MAX. MIN. L W H BOLT B SINGLE BARREL 00 00 00 0 00 00 00 00 00 00 000 *A- *A- *A-/0 A-/0 A-0 A-00 A-0 A-00 A-00 A-00 A-000 # STR /0 STR

More information

DMC2. Installation Guide Version 1.0. Area for main photograph. Area for insert photo. W: 46.1mm up to 79 mm H: 46.1mm

DMC2. Installation Guide Version 1.0. Area for main photograph. Area for insert photo. W: 46.1mm up to 79 mm H: 46.1mm Area for main photograph Area for insert photo W: 46.1mm up to 79 mm H: 46.1mm X: 12.6mm absolute on page Y: 132.6mm abs on page This insert has a shadow DMC2 Installation Guide Version 1.0 Contents DMC2

More information

FT & RT Test Switches

FT & RT Test Switches GE Grid Solutions FT & RT Test Switches Key Benefits The FT Switches and FT Test Plugs have all the features necessary for applications involving the measurement of individual currents and voltages to

More information

Basketball Shot Clock Set LX2180 Manual

Basketball Shot Clock Set LX2180 Manual Basketball Shot Clock Set LX2180 Manual 72 Industrial Boulevard Wrightsville, GA 31096 Phone: (800) 445-7843 Fax: (800) 864-0212 www.electro-mech.com LX2180 Revision 5 February 8, 2013 Table of Contents

More information

Series Amp Pad Mount Quick Connect Input and Output Power Panels

Series Amp Pad Mount Quick Connect Input and Output Power Panels Series 300 2000-4000 Amp Pad Mount Quick Connect Input and Output Power Panels DANGER is used in this manual to warn of a hazard situation which, if not avoided, will result in death or serious injury.

More information

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD United States 24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Approvals: IEC 60947-2 Rated

More information

Series Amp Quick Connect Input and Output Power Panels

Series Amp Quick Connect Input and Output Power Panels Series 300 1200-1600 Amp Quick Connect Input and Output Power Panels DANGER is used in this manual to warn of a hazard situation which, if not avoided, will result in death or serious injury. WARNING is

More information

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors B Curve NC100H Supplementary Protectors Rating 1P 2P 3P 4P 80 MG27164 MG27175 MG27186 MG27197 MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors C Curve NC100H Supplementary Protectors

More information

IRONRIDGE PRODUCT CATALOG

IRONRIDGE PRODUCT CATALOG IRONRIDGE PRODUCT CATALOG Effective March 15, 2011 Product Catalog March 15, 2011 2 What s New: 1. New Products: a. End Caps for XRS and XRL Rails Page 6 b. End Clamps I, J, K, Page 7 and updated sizing

More information

Multi Unit Enclosed Meter

Multi Unit Enclosed Meter Contents Description Page Introduction Preliminary comments and safety precautions............................... 2 Warranty and liability information................ 2 Safety precautions..............................

More information

60103 Circuit Breaker

60103 Circuit Breaker 6003 Circuit Breaker United States MINIATURE CIRCUIT BREAKER, 20/240VAC, 2A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Circuit Breaker Type: Standard

More information

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors UL Recognized C60N Supplementary Protectors B Curve C60N Supplementary Protectors 1 MG24110 MG24125 MG24140 MG24155 15 MG17406 MG17436 MG17461 1.2 MG17402 MG17432 16 MG24118 MG24133 MG24148 MG24163 1.5

More information

Installation Guide. Retrofit Kit for USB Ready Intraoral Systems

Installation Guide. Retrofit Kit for USB Ready Intraoral Systems Installation Guide Retrofit Kit for USB Ready Intraoral Systems Table of Contents Wall-Mount Retrofit Kit... 2 Introduction... 2 Connecting the Articulating and Horizontal Arm Cables... 2 Installing the

More information

C5C Cross-Connect System

C5C Cross-Connect System C5C Cross-Connect System I N S T A L L A T I O N I N S T R U C T I O N High-Density Connection Blocks 1.0 General Product Information The C5C cross-connect system is comprised of a high-density connection

More information

Illustrated Parts List. Generator Systems. Reproduction MODEL Not for. 12,000 Watt. Generator Systems

Illustrated Parts List. Generator Systems. Reproduction MODEL Not for. 12,000 Watt. Generator Systems Illustrated Parts List Generator Systems MODEL 12,000 Watt Generator Systems Manual Part No. Revision D Rev. Date: 8/9/2016 Table Of Contents PRODUCT COMPONENTS PAGES Power Group... 4 Alternator... 6

More information

PanelFAST. Setting a new standard for immediate product availability with Square D Ready to Install (RTI) Panelboards

PanelFAST. Setting a new standard for immediate product availability with Square D Ready to Install (RTI) Panelboards PanelFAST Setting a new standard for immediate product availability with Square D Ready to Install (RTI) Panelboards Whether you planned ahead or have an unexpected project, why wait? You should expect

More information

UL 489 DIN rail branch circuit breakers

UL 489 DIN rail branch circuit breakers UL 9 DI rail branch circuit breakers FAZ-A circuit breakers Product Overview UL 9 DI rail branch circuit breakers FAZ-A circuit breakers PRODUCT OVERVIEW Optimum and efficient protection Optimum product

More information

A0 & CB0. Single Row Terminal Blocks. Dimensions- Inches (Millimeters) Specifications CB0

A0 & CB0. Single Row Terminal Blocks. Dimensions- Inches (Millimeters) Specifications CB0 A0 & CB0 Dimensions- Inches (Millimeters) A0 0.12 (3.0) Ø A00110407 0.250 (6.35) Specifications Rating: 10 A, 300 V Center Spacing: 0.25 (6.35 mm) Wire Range: #16-30 AWG Screw Size: M3.0 nickel-plated

More information

Terminal Blocks - Single Row. Series A3000, LP3000 & CB3000 Single Row Terminal Blocks

Terminal Blocks - Single Row. Series A3000, LP3000 & CB3000 Single Row Terminal Blocks Series A3000, LP3000 & CB3000 Single Row Terminal SPECIFICATIONS Rating: A3: 30A, 600V* #12-22 AWG LP3: 30A, 150V #12-22 AWG CB3: 30A, 600V #12-22 AWG Wire Range: #12-22 AWG CU Center Spacing: 0.437 or

More information

Solar Combiner Enclosure

Solar Combiner Enclosure Installation Instructions Solar Combiner Enclosure Catalog Numbers 1000-SB006, 1000-SB012 Topic Page Description 1 Important Safety Instructions 3 Nameplate Data 4 Planning for Installation 4 Install the

More information

SECTION DISCONNECT SWITCHES

SECTION DISCONNECT SWITCHES SECTION 16440 DISCONNECT SWITCHES PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Division 01 Specification

More information

Innovative POWER Solutions

Innovative POWER Solutions Innovative POWER Solutions ISO 9001 : 2008 REGISTERED QUALITY MANAGEMENT SYSTEM PANTROL, INC. INVITES YOU TO REVIEW A SAMPLING OF OUR STANDARD PRODUCTS LINE. FOR SPECIAL APPLICATIONS OR CONFIGURATIONS

More information

Instruction Manual IM E Table of Contents

Instruction Manual IM E Table of Contents Instruction Manual IM01005031E Effective For Mounting External To Table of Contents 1.0 Introduction 2.0 Installation 3.0 Operating Features 4.0 Troubleshooting 5.0 Specifications 6.0 Ordering Guidelines

More information

INSTRUCTION MANUAL RA 59 RACK ADAPTER. 1) This manual is valid for the following Model and associated serial numbers: MODEL SERIAL NO. REV. NO.

INSTRUCTION MANUAL RA 59 RACK ADAPTER. 1) This manual is valid for the following Model and associated serial numbers: MODEL SERIAL NO. REV. NO. INSTRUCTION MANUAL RA 59 RACK ADAPTER KEPCO INC. An ISO 9001 Company. MODEL RA 59 RACK ADAPTER ORDER NO. REV. NO. IMPORTANT NOTES: 1) This manual is valid for the following Model and associated serial

More information

Power Base AI. Power Base AI. Technical Sheets

Power Base AI. Power Base AI. Technical Sheets Power Base AI Power Base AI Technical Sheets odular Electrical System System Overview Haworth s Power Base AI modular electrical system provides a flexible, reconfigurable power distribution infrastructure

More information

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD United States MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD Product Information Features and Specifications For Use With: OEM Panels Approvals: UL

More information

NCH-1000 (Multiple Breaker Types) Installation Instructions

NCH-1000 (Multiple Breaker Types) Installation Instructions 20M1 12345678 NCH-1000 (Multiple Breaker Types) Installation Instructions DOC. #560502100 C 7/30/04 PRINTED IN U.S.A. Regulatory Compliance Safety This device has been tested and found to be in compliance

More information

Free-Stand Type 12 Disconnect Enclosures. Heavy-Duty Free-Stand Disconnect Enclosure, Type 12

Free-Stand Type 12 Disconnect Enclosures. Heavy-Duty Free-Stand Disconnect Enclosure, Type 12 Spec-00251 FPH FX (763) 422-2600 422-2211 Disconnect Free-Stand Universal-Cutout Disconnect Enclosures Heavy-Duty Free-Stand Disconnect Enclosure, Type 12 Industry Standards UL 508A Listed; Type 12; File

More information

Zenith Series DPB Distributed Power Busway

Zenith Series DPB Distributed Power Busway Critical Power from GE Zenith Series DPB Distributed Power Busway Key Solutions for Datacenter Overhead Power Distribution Generation 2 GE Series DPB Gen 2 Bus System Flexible. Robust. Efficient. Specifically

More information

NATIONAL DEVICES. Modular Design Receptacles, Switches, Pilot Lights. (45 mm)... Page 46

NATIONAL DEVICES. Modular Design Receptacles, Switches, Pilot Lights. (45 mm)... Page 46 SECTION C NATIONAL DEVICES Modular Design Receptacles, Switches, Pilot Lights Product Installation Guide... Pages 38, 39 Modular Receptacles ( mm)... Page 40 Modular Devices ( mm)... Page 41 Dimensional

More information

Surge Protection. A complete offering of surge protection products for homes, businesses, schools and light commercial applications.

Surge Protection. A complete offering of surge protection products for homes, businesses, schools and light commercial applications. Eaton Surge Products Surge Protection A complete offering of surge protection products for homes, businesses, schools and light commercial applications. Eaton offers a Complete Line of Surge Protection.

More information

CONGRATULATIONS!! You have given yourself the power & flexibility needed in today s ever-changing exterior environment. Got Lights?

CONGRATULATIONS!! You have given yourself the power & flexibility needed in today s ever-changing exterior environment. Got Lights? CONGRATULATIONS!! FOCUS is pleased to introduce the MST, MAS, MLT & MAL Stainless Steel and Aluminum 12 Volt Weatherproof Transformer Series designed with the customer in mind. Why use a M2000 series transformer?

More information

Haworth Power Technical Sheets January 2018

Haworth Power Technical Sheets January 2018 Haworth Power Technical Sheets January 2018 Includes Accessories This page intentionally left blank. Table of Contents Desk Top Port Power Tap Cord Power Tap Conduit Enchanced Power Module Flip Top Unit

More information

Installation Notes TII Model 341 Protector

Installation Notes TII Model 341 Protector Installation Notes TII Model 341 Protector (ATT-IS PEC 32918) for MERLIN Communications System In Range Out of Building (IROB) Station Installation By Trained Technician Only WARNING: Failure to follow

More information

The City of Winnipeg Dry Type Transformers up to 600 V Primary Section Bid Opportunity No Page 1 of 2

The City of Winnipeg Dry Type Transformers up to 600 V Primary Section Bid Opportunity No Page 1 of 2 The City of Winnipeg Dry Type Transformers up to 600 V Primary Section 26121601 Bid Opportunity No. 1196-2014 Page 1 of 2 Part 1 General 1.1 RELATED REQUIREMENTS.1 Section 26 05 01 - Common Work Results

More information

BCM2 Series Branch Circuit Monitors Quick Setup Guide

BCM2 Series Branch Circuit Monitors Quick Setup Guide BCM2 Series Branch Circuit Monitors Quick Setup Guide Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable

More information

Power-Over-Ethernet Weatherproof 18" x 16" x 8" Enclosure with Equipment Mounting Plate and Cooling Fans

Power-Over-Ethernet Weatherproof 18 x 16 x 8 Enclosure with Equipment Mounting Plate and Cooling Fans Power-Over-Ethernet Weatherproof 18" x 16" x 8" Equipment Mounting Plate and Cooling Fans Applications and Features Applications: Remote Wireless LAN WiFi equipment installations using Power- Over-Ethernet

More information

Ag Leader Technology Insight. Direct Command Installation Spra-Coupe 7000 Series

Ag Leader Technology Insight. Direct Command Installation Spra-Coupe 7000 Series Note: Indented items indicate parts included in an assembly listed above. Part Name / Description Part Number Quantity Direct Command Spra-Coupe 7000 Kit 4100531 1 Liquid Product Control Module 4000394

More information

Effective May 2018 Supersedes October 2017

Effective May 2018 Supersedes October 2017 Technical Data TD280028EN Supersedes October 2017 COOPER POWER SERIES NOVA NX-T Recloser, Form 6 NX-T, and Form 6LS NX-TRecloser Control and Accessories Ordering Guide Eaton provides reliable, economical

More information

SECTION WIRING DEVICES PART 1 - GENERAL. A. Drawings and Division 1 Specification Sections, apply to this Section.

SECTION WIRING DEVICES PART 1 - GENERAL. A. Drawings and Division 1 Specification Sections, apply to this Section. SECTION 16140 WIRING DEVICES 1.01 RELATED DOCUMENTS PART 1 - GENERAL A. Drawings and Division 1 Specification Sections, apply to this Section. 1.02 SUMMARY A. This Section includes receptacles, connectors,

More information

SURFACE CONTROLTrack INSTALLATION INSTRUCTIONS

SURFACE CONTROLTrack INSTALLATION INSTRUCTIONS SURFACE CONTROLTrack INSTALLATION INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS - For use with CONTROLTrack System Only When installing or using this track system, basic safety precautions should always be

More information

ML200 Fanless Mini-ITX Enclosure

ML200 Fanless Mini-ITX Enclosure ML200 Fanless Mini-ITX Enclosure Assembly Guide Version 1.1 PN: ML200 1 Table of Contents I. Product Description... 3 II. Included Parts... 3 III. Basic Chassis Assembly... 5 IV. Installation... 12...

More information

General Description. Product Application. Eaton Innovative Technology Special Applications

General Description. Product Application. Eaton Innovative Technology Special Applications Eaton Innovative Technology Special s Technical Data New Information Page General.............................................. 1 Product.............................................. 1 Dedicated Load

More information

4.3. Switchboards. Contents Description Pow-R-Line Drawout Molded Case Circuit Breaker Switchboards Product Selection...

4.3. Switchboards. Contents Description Pow-R-Line Drawout Molded Case Circuit Breaker Switchboards Product Selection... .3 Product Description Drawout molded case circuit breaker switchboard Front accessible Front connected Through-the-door design drawout mechanism through 600A Insulated case UL 89 breakers up to 200A Visual

More information

GFCI (RCD) RECEPTACLES AND PLUGS 2 Pole 3 Wire Grounding

GFCI (RCD) RECEPTACLES AND PLUGS 2 Pole 3 Wire Grounding GFCI (RCD) RECEPTACLES AND PLUGS 2 Pole 3 Wire Grounding AU1-10R AU1-10P FR1-R EU1-P Cat. No. Drawing Configuration Australian GFCI (RCD) angle plug. trip. 10 ampere 230 volt, 50 Hz. 20 watt maximum. Test

More information