Meter Breakers. Technical Data. Contents
|
|
- Alaina Snow
- 5 years ago
- Views:
Transcription
1 Technical Data Effective: October Page ew Information Meter reakers Contents Description Page Residential Meter reakers Residential Meter reakers Product Selection , ox Styles Typical Diagrams Dimensions and Knockouts Type Residential 00 mpere and 00 mpere House Panels Product Selection Typical Diagrams Dimensions and Knockouts Type R Residential 00 mpere and 00 mpere House Panels Product Selection Typical R Diagrams , Dimensions and Knockouts Meter reaker Family TD.F.0.T.E
2 Technical Data Page Effective: October Meter reakers Residential Meter reakers Residential Meter reakers Product Description meter breaker is service entrance equipment that consists of a single meter socket and loadcenter (circuit breaker distribution section) or meter socket and main breaker combined in one enclosure. Sometimes called Combos, ll-in-ones, Meter Centers or Meter Mains these units are increasing in popularity as the socket and loadcenter or main breaker are located in one location, thus providing the contractor with a labor and material savings when installing. pplication Description In addition to residential installations, meter breakers are equally applicable for rural service entrance, mobile homes, and construction site temporary power. Meter breakers are most often sold in the Western, Southwestern and Southeastern United States. The popularity of meter breakers is continuing to increase as more utilities deregulate and pass the responsibility of supplying watt-hour meter sockets on to the electrical contractor. pplication Considerations We have the meter breaker to meet your application. Cutler-Hammer offers: on-euserc. EUSERC/West Coast (Electrical Utility Service Equipment Requirements Committee). House Panels. Commercial Safety Sockets. on-euserc The Cutler-Hammer line of on-euserc meter breakers is designed for customers served by utilities that are not members of EUSERC. EUSERC/West Coast The Cutler-Hammer line of EUSERC approved devices adheres to the agreed upon standards. EUSERC utilities are predominately located in the Western United States, but some Eastern and Midwestern utilities are also members. These units can also be used in many on-euserc areas. House Panels Meter breaker device rated at pplied in EUSERC and on-euserc areas. Commercial Safety Sockets pplied in EUSERC and on-euserc service areas and used in commercial applications. Standards and Certifications UL Specification. UL File umber E. EIC-EEI-EM Standards (MSJ-). Meet EUSERC Utility requirements where noted. Documented Seismic Qualified UC and CC Title. Product Specifications Ratings single-phase, -wire, 0/0V C. 0 through ampere main breaker and main lug types.,000 amperes rms symmetrical short circuit rating. Features, enefits and Functions oth R and type branch circuit breaker styles available. Meets latest EC wire bending space requirements. Slotted sealing screws at hub with sealing provision provided. Surface units are supplied with mounting tabs. Semi-flush units are supplied with stucco flange. Meter socket ring landing will accept locking security rings. Overhead or underground service. Fifth jaw can be installed in the o clock or o clock position. Semi-flush with nail flange or surface mounting. Meter mounting and underground pull sections are utility sealable. Units are rated a minimum of,000 IC; some units are,000 IC. umerous units supplied with center keyhole for ease of mounting. TD.F.0.T.E
3 Meter reakers Technical Data Effective: October Page Product Selection Table. Combination Service Entrance Devices (on-euserc) mpere Rating ypass Service IC Jaws Distribution Main ranch reaker Type Style Meter Mains (no distribution section included) 0 0 OH k k k See Page for box details. Provision for main is provided. WM style devices accept Main reaker style R, -Pole. Panels are specifically designed for the Georgia Power Service Territory, but may be used in any service territory that has the same design requirements. When a provision for main is provided, order one of the main breakers listed in Table. ll panels are dual labeled to accept Types W or CSR Main reakers. MCK lug kit is needed for load side cable connection for Meter Mains. Please order separately. Single cover design. Copper bus. Units come with feed-through lugs. One-piece cover on utility side Florida approved. Per installed main breaker rating. Table. Main reaker Selection Chart less Meter Mains (no distribution section included) 0 Horn Horn k k k Style ll-in-ones (includes distribution section) 0 0 k k k k k Will accept maximum four -pole, two -pole, or two quad breakers / / / / less ll-in-ones (includes distribution section) Horn Horn Horn Horn Horn Horn Horn Horn Horn Maximum mpere Rating 0 k k k k k k / / / / / / / / / Pole Pole / / Pole / Pole 0/0 0/0 0/0 0/0 Provision CSR0 CSR Provision CSR CSR0 CSR CSR Provision Provision Provision Refer to Distribution Refer to Distribution CSR0 CSR0 W CSR CSR W W Provision Provision Provision Provision Provision CSR0 CSR Main Lugs Main Lugs Provision Provision Main Lugs CSR Main Lugs W Provision Provision Provision Catalog umber,000 IC,000 IC W W0 W Load Side Lug Kit for W and CSR reakers. WH WH0 WH When a provision for main is provided, order one of the main breakers listed in Table. ll panels are dual labeled to accept Types W or CSR Main reakers. R R R R R R R R R R R R R R R R CSR CSR0 CSR MCK Catalog umber WMR M0TSCR MTSCR MPTSCR CMTS M0TSC MTS MTSC MPTS MPSD MPTSD ox Dimension WMSC WMSCR CMLTS CM0TS CM0S MTS CMTS CMS MTS MTSCU MPTS MPTSCU MPSTD MPTSD MPTSCUD CMTS CMTSD CMLTS CMLTSD CMPTS CMPTSD MLTS CMTS MLTSD MTS MPTS MPSD MPTSD Information Pages Knockout / Refer to drawing -00 / TD.F.0.T.E
4 Technical Data Page Effective: October Meter reakers Table. Combination Service Entrance Devices (EUSERC) mpere Rating ypass Service IC Jaws Distribution Style Meter Mains (no distribution section included) 0 0 k k k k See Page for box details. Interrupting rating is dependent on the main breaker that is installed. Semi flush flange, not full stucco flange Units come with feed-through lugs. Unit has copper bus. When a provision for main is provided, order one of the main breakers listed in Table. ll panels are dual labeled to accept Types W or CSR Main reakers. Use WM0SMK if second main kit is needed. Table. Main reaker Selection Chart / / / / Style ll-in-ones (includes distribution section) Maximum mpere Rating 0 OH OH OH OH OH OH OH k k k k k k k k k k k k k k k k k k k k k k k k k k / / / / / / / / 0/0 / / / / Pole Pole Pole Pole 0/0 0/0 0/0 / 0 0/0 / 0/0 / Main MLO MLO W0 CSR0 W CSR MLO MLO Provision R0 R0 0X R0 R R R R X CSR0 CSR0 W0 W0 W0 W CSR W Provision Provision Main Lug Main Lug Main Lug Main Lug W W Provision CSR W CSR W W W CSR ranch reaker Type R R When a provision for main is provided, order one of the main breakers listed in Table. ll panels are dual labeled to accept Types W or CSR Main reakers. R R R R R R R R R R R R R R R R R R R R R R R Catalog umber,000 IC,000 IC W W0 W Load Side Lug Kit for W and CSR reakers. WH WH0 WH Catalog umber ox Information Pages Surface Flush Dimension Knockout MELTS CMELTS ME0TS CME0TS METS CMETS MELTS CMELTS MEPTS ME0TS ME0S CME0S ME0TS METS METS MES MES CMES CME0TS CME0S ME0S ME0TS ME0TS METS CMETS METS MEPTSCU MEPTS CMELTS CMELS MELTS MELS METS MES MEPTS CMES ME00TS CMETS WM0S WM0SL WMS CMES CSR CSR0 CSR MCK MELTF CMELTF ME0TF CME0TF METF CMETF MELTF CMELTF / ME0TF ME0F CME0F ME0TF METF METF MEF MEF CMEF CME0TF CME0F ME0F ME0TF ME0TF METF CMETF METF / / / CMELF / MELF METF MEF MEPTF CMEF ME00TF CMETF WM0 / WMF CMEF TD.F.0.T.E
5 Meter reakers Technical Data Effective: October Page ox Styles C D E Figure. Five Different Styles (Shapes) of Product Table. ox Dimensions ox umber Dimensions in Inches Height Width Depth -/ (.) -/ (0.) -/ (0.) -/ (.) -/ (.) -/ (.) -/ (0.) -/ (0.) -/ (.) Table. Meter reaker Parts Description -/ (.) -/ (0.) -/ (.) -/ (0.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (0.) -/ (.) -/ (.) -/ (.) (.) -/ (.) th Jaw Kits Compact and Standard Styles (M & CM) WM Style Manual ypass Kits Style Units Only (M) Horn ypass Kits less Style Units Only (M & CM) (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) Catalog umber ox Style C C C C D E MMJKOP WMJ MMPM MMPH Table. Wire Size Chart Main Wire Size Range Cu/l 0ºC or ºC for Terminals R0 R0 R0 R0 R0 R0 W W0 W WH WH0 WH CSR CSR0 CSR Main Lugs Main Lugs MCK # kcmil # /0 kcmil # /0 kcmil # /0 kcmil # /0 kcmil # /0 kcmil # 00 kcmil # 00 kcmil # 00 kcmil # 00 kcmil # 00 kcmil # 00 kcmil #/0 0 kcmil #/0 0 kcmil #/0 0 kcmil # 00 kcmil Table. Wire Size is Determined by the Circuit reaker Installed in the Enclosure. Maximum Wire Size and mpere Rating is Determined as Follows: Wire/pplication luminum Standard luminum Service Entrance Copper Standard and Service Entrance Maximum Wire Size 0 kcmil 0 kcmil 0 kcmil mpere Rating Table. Hub Selection Chart Hub Size Dimensions in Inches (mm) (.) -/ (.) -/ (.) (0.) -/ (.) (.) Catalog umber DS0H DSH DS0H DSH DS0H DS00H TD.F.0.T.E
6 Meter reakers Technical Data Effective: October Page Typical Diagrams (Residential Meter reakers) onded eutral onded eutral 0 Type CSR #- WG #- WG #-/0 WG #-0 WG Figure. Catalog umbers CMES, CMEF, CME0S and CME0F #- WG #-/0 WG #-0 WG Figure. Catalog umbers CMS, CME0S, CME0F, CMES, CMEF, CMES, CMEF, CM0S and CMS onded eutral onded eutral #- WG #-/0 WG #-0 WG Figure. Catalog umbers CMELS and CMELF TD.F.0.T.E
7 Meter reakers Technical Data Effective: October Page Typical Diagrams (Residential Meter reakers) Install Maximum Type CSR ➀ onded eutral onded eutral onded eutral #-/0 WG #- WG #-0 WG Figure. Catalog umbers CMTS, CME0TF, CME0TS, CMETF and CMETS Factory installed MCK Kit for C/ load lugs. #-/0 WG #- WG #-/0 WG #-0 WG Figure. Catalog umbers CMELTS, CMELTF and CMLTS #- WG #-/0 WG #-0 WG Figure. Catalog umbers CMELTS and CMELTF Type CSR Maximum Main #-/0 WG #- WG #-/0 WG #-0 WG #-00 WG onded eutral 0 #- WG #-/0 WG #-/0 WG #-0 WG Figure. Catalog umbers CMETS, CMETF, CMTS, CM0TS, CME0TS and CME0TF Figure. Catalog umbers ME0TS, ME0TF, METS and METF TD.F.0.T.E
8 Technical Data Page Effective: October Meter reakers Typical Diagrams (Residential Meter reakers) onded eutral onded eutral onded eutral onded eutral 0 Disconnect Type W, WH or CSR #- WG #-/0 WG #-0 WG #- WG #-/0 WG #-0 WG #- WG #-/0 WG #-0 WG Figure. Catalog umbers ME0S, ME0F, MES and MEF Figure. Catalog umbers ME0S, ME0F, MES and MEF Figure. Catalog umbers MELS and MELF #- WG #-/0 WG #-0 WG Figure. Catalog umbers MES and MEF TD.F.0.T.E
9 Meter reakers Technical Data Effective: October Page Typical Diagrams (Residential Meter reakers) Maximum Type W, WH or CSR Maximum Type W, WH or CSR eutral MCK Kit for C/ Load Lugs L L onded eutral onded eutral #-/0 WG #- WG #-/0 WG #-0 WG Figure. Catalog umbers MELTS and MELTF #-/0 WG #- WG #-/0 WG #-0 WG Figure. Catalog umbers ME0TS, ME0TF, METS, METF and MTS #-/0 WG #-/0 WG #-0 WG Figure. Catalog umbers MEPTS, METS, METF, ME0TS and ME0TF Maximum Type W, WH or CSR eutral #-/0 WG #- WG #-/0 WG #-0 WG Figure. Catalog umbers MELTS and MELTF #-/0 WG #- WG #-/0 WG #-0 WG Figure. Catalog umbers METS, METF, ME0TS and ME0TF TD.F.0.T.E
10 Technical Data Page Effective: October Meter reakers Typical Diagrams (Residential Meter reakers) onded eutral onded eutral Maximum Type W, WH or CSR onded eutral #- WG #-0 kcmil #-/0 WG #-00 kcmil #-00 kcmil Figure. Catalog umbers MTSCU, MEPTS and MEPTSCU #- WG #-0 kcmil #-/0 WG #-00 kcmil Figure. Catalog umber MELTS #- WG #-0 kcmil #-/0 WG #-00 kcmil Figure. Catalog umber CMELTS onded eutral Maximum Service Disconnect Type W, WH or CSR #- WG #-0 kcmil #-/0 WG Figure 0. Catalog umbers MPTSD, MEPTS, MEPTF, METS, METF TD.F.0.T.E
11 Meter reakers Technical Data Effective: October Page Typical Diagrams (Residential Meter reakers) TH Jaw Factory Installed on CMTSD and CMPTSD Only onded eutral onded eutral th Jaw Factory Installed on CMLTSD Only onded eutral Ground ar Maximum Type CSR #- WG #-0 kcmil #-/0 WG #-00 kcmil #-00 kcmil #-/0 WG #-0 kcmil #-00 kcmil #- WG #-0 kcmil #-/0 WG #-00 kcmil Figure. Catalog umbers CMPTSD and CMPTS Figure. Catalog umbers MLTS and MLTSD Figure. Catalog umbers CMLTSD and CMLTS th Jaw Factory Installed on CMTSD and CMPTSD Only onded eutral onded eutral Maximum Type CSR Maximum Type CSR #- WG #-0 kcmil #-/0 WG #-00 kcmil #-00 kcmil 0 #- WG #-0 kcmil #-/0 WG #-00 kcmil Figure. Catalog umbers CMTS and CMTSD Figure. Catalog umbers CMTS TD.F.0.T.E
12 Technical Data Page Effective: October Meter reakers Typical Diagrams (Residential Meter reakers) Factory Installed Type CSR Factory Installed Type W #- WG #-/0 WG # WG-0 kcmil onded eutral #- WG #-/0 WG # WG-0 kcmil onded eutral Figure. Catalog umbers CMESH, CMETS and CMETF Figure. Catalog umbers ME00TF, ME00TS and ME00SH TD.F.0.T.E
13 Meter reakers Technical Data Effective: October Page Typical Diagrams (on-euserc Meter reaker Design) Included in M0TSCR Maximum Type CSR onded eutral Maximum Service onded eutral Maximum Type R, or RH Type W, onded eutral #-/0 WG #-0 kcmil #-0 kcmil #-00 kcmil #- WG #-0 kcmil #-/0 WG #-00 kcmil #-00 kcmil Equipment Ground 0 #- WG #-/0 WG #-0 kcmil Figure 0. Catalog umbers M0TSC, M0TSCR, MTSCR, MPTSCR and MTSC Figure. Catalog umbers MPSTD, MTS, MTSCU, MPTS, MPTSCU, MPTSD and MPTSCUD Figure. Catalog umbers METS, METF, ME0TS and ME0TF onded eutral Maximum Type W, WH or CSR ➀ onded eutral Maximum Service Disconnect Type W, WH or CSR 0 #-/0 WG #-0 kcmil #-00 kcmil #-00 kcmil 0 0 #- WG #-0 kcmil #-/0 WG Figure. Catalog umbers MPSD, MTS, MPTS and MPTSD Use MCK for C/ Load Lugs. Figure. Catalog umbers MPSD, MTS, MPTS and MPTSD TD.F.0.T.E
14 Technical Data Page Effective: October Meter reakers Dimensions and Knockouts (Residential Meter reakers) Dimensions in Inches (mm) Keyhole Knockouts on Sides for Stucco Units Only. -/ (.) -/ (.) Top Stucco Top Surface -/ (.) -/ (.) ottom ottom Figure. Knockouts for Stucco and Surface Units Catalog umbers CME0F, CMEF, CMEF, CME0F, CMEF, CMELF, MEF, ME0F, ME0F, MEF, MELF and MEF Figure. Knockouts for Stucco and Surface Units Catalog umbers CME0S, CMES, CMES, CME0S, CMES, CMELS, MES, ME0S, ME0S, MES, MELS, MES, CM0S and CMS Table. Top Endwall (Surface) Hub Provision DS0H DSH DS0H DSH DS0H DS00H DS00P (dapter Plate if using DS H hubs only) Use when DS H Type, -/ and -/-inch hubs are needed. Table. ottom Endwall Knockout Size (Dimensions in Inches) /, /, / /, /,, -/, -/, -/, -/,, -/, Quantity Table. Top Endwall (Stucco) Knockout Size (Dimensions in Inches) -/, -/,, -/, -/, -/ /, /, /, / / Quantity TD.F.0.T.E
15 Meter reakers Technical Data Effective: October Page Dimensions and Knockouts (Residential Meter reakers) Dimensions in Inches (mm) Keyhole Knockouts on Sides for Stucco Units Only. -/ (.) -/ (.) Top Stucco Top Surface -/ (.) -/ (.) ottom Figure. Knockouts for Stucco and Surface Units Catalog umbers CMELTF, CMELTF, CMETF, CME0TF, CME0TF, CMETF, MELTF, MELTF, ME0TF, METF, ME0TF, METF, ME0TF, METF, ME0TF and METF ottom Figure. Knockouts for Stucco and Surface Units Catalog umbers CMTS, CMELTS, CMLTS, CMELTS, CMETS, CME0TS, CME0TS, CMETS, MELTS, MELTS, ME0TS, METS, ME0TS, METS, ME0TS, METS, MEPTS, ME0TS, METS, CM0TS, CMTS and MTS Table. Top Endwall (Surface) Hub Provision DS0H DSH DS0H DSH DS0H DS00H DS00P (dapter Plate) Use when DS H Type, -/ and -/-inch hubs are needed. Table. ottom Endwall Knockout Size (Dimensions in Inches) / /, / /, /,, -/, -/, -/, -/,, -/, Quantity Table. Top Endwall (Stucco) Knockout Size (Dimensions in Inches) -/, -/,, -/, -/, -/ /, /, /, / / Quantity TD.F.0.T.E
16 Technical Data Page Effective: October Meter reakers Dimensions and Knockouts (Residential Meter reakers) Dimensions in Inches (mm) Keyhole Knockouts on Sides for Stucco Units Only. -/ (.) -/ (.) Top Stucco Top Surface -/ (.) -/ (.) ottom ottom Figure. Knockouts for Stucco and Surface Units Catalog umbers ME0TF, METF and MEPTF Figure 0. Knockouts for Stucco and Surface Units Catalog umbers ME0TS, METS, MEPTS, MEPTSCU, MEPTS, MELTS, CMELTS, CMPTS, CMPTSD, CMTS, CMTSD, MLTS, MLTSD, CMLTS and CMLTSD Table. Top Endwall (Surface) Hub Provision DS0H DSH DS0H DSH DS0H DS00H DS00P (dapter Plate) Use when DS H Type, -/ and -/-inch hubs are needed. Table. ottom Endwall Knockout Size (Dimensions in Inches) / /, / /, /,, -/, -/, -/, -/,, -/, Quantity Table. Top Endwall (Stucco) Knockout Size (Dimensions in Inches) -/, -/,, -/, -/, -/ /, /, /, / / Quantity TD.F.0.T.E
17 Meter reakers Technical Data Effective: October Page Dimensions and Knockouts (Residential Meter reakers) Dimensions in Inches (mm) -/ (.) Top Flush CMETF ME00TF -/ (.) -/ (.) Top Surface Top Surface -/-inch Hub -/ (.) -/ (.) ottom CMETS ME00TS ottom CMESH ME00SH Figure. Knockouts for Stucco and Surface Units Table. Top Endwall (Surface) Table 0. Top Endwall (Stucco) Table. ottom Endwall Hub Provision Knockout Size (Dimensions in Inches) Quantity Knockout Size (Dimensions in Inches) Quantity DS0H DSH DS0H DSH DS0H DS00H DS00P (dapter Plate) Use when DS H Type, -/ and -/-inch hubs are needed. -/, -/,, -/ /, / /, / /, /,, -/, -/, -/,, -/, -/, -/,, -/, TD.F.0.T.E
18 Technical Data Page Effective: October Meter reakers Dimensions and Knockouts (on-euserc Meter reaker Design) Dimensions in Inches (mm) -/ (.) -/ (.) Top Surface Top Surface (Catalog umbers with SC and SCR Suffix Only) -/ (.) -/ (.) ottom ottom Figure. Knockouts for on-euserc Units Catalog umbers MTS, MPTS, MPTS, MPTSCU, MTS, MTSCU, MPTS, MTS, MPSD, MPSTD and MPSD Figure. Knockouts for on-euserc Units Catalog umbers M0TSCR, MTSCR, MPTSCR, M0TSC and MTSC Table. Top Endwall (Surface) Hub Provision DS0H DSH DS0H DSH DS0H DS00H DS00P (dapter Plate) Table. ottom Endwall Knockout Size (Dimensions in Inches) / / /, / /, -/, -/,, -/ -/,, -/, Quantity TD.F.0.T.E
19 Meter reakers Technical Data Effective: October Page Type Residential 00 mpere and 00 mpere House Panels Type Residential 00 mpere and 00 mpere House Panels Product Description House Panel is a service entrance device that consists of a meter socket and a distribution section. The unit is rated at 00 amperes or 00 amperes. pplication Description In addition to residential installations, a house panel could also be used for an apartment/condominium, clubhouse or common area. Verify local utility requirements before sale. Features, enefits and Functions 00 mpere and 00 mpere House Panels Underground feed only. RH type hub provisions on bottom endwall. Meets EUSERC requirements. Plug-on 00 ampere meter socket (0 ampere continuous). EM R Rainproof. Lever bypass socket available on certain catalog numbers. Service entrance equipment and UL listed. Uses branch breakers. Product Selection Table mpere House Panels mpere Rating Security ypass Main reaker (Included) Optional Main reaker (ot Included) Service Type IC Distribution Type Diagram Side Main Lugs and eutral Catalog umber Surface Semi Flush less less less less Lever Lever Lever Lever W W CSR W W CSR CSR Provision CSR CSR CSR CSR W CSR CSR CSR CSR Confirm security type for individual EUSERC utility requirements. Semi Flush Flange kit HPPR. If manual bypass is needed, order bypass kit HPPK. Feed-through lugs included.,000k,000k,000k,000k,000k,000k,000/,000k,000k,000k,000k,000/,000k / / / Landing studs for utility supplied compression lugs. CG0S CG0S CG0SH CG0S CG0S CG0SH CG0SHL CGP00S CG0SHL CG0SHL CG0SHL TD.F.0.T.E
20 Technical Data Page 0 Effective: October Meter reakers Technical Data and Specifications Typical Diagrams (Type Style House Panels) FCTORY ISTLLED DISCOECT (OPTIOL) FCTORY/FIELD ISTLLED 0 MX. DISCOECT TYPE 00 MPS (0 MPS COTIUOUS) FCTORY ISTLLED DISCOECT (OPTIOL) FCTORY/FIELD ISTLLED 0 MX. DISCOECT TYPE FCTORY ISTLLED DISCOECT (OPTIOL) FCTORY/FIELD ISTLLED MX. DISCOECT TYPE W LIE EQUIPMET GROUDIG TERMILS LIE 00 MPS (0 MPS COTIUOUS) EQUIPMET GROUDIG TERMILS LIE 00 MPS (0 MPS COTIUOUS) EQUIPMET GROUDIG TERMILS ODED EUTRL ODED EUTRL ODED EUTRL Figure. Type Diagram Figure. Type Diagram Figure 0. Type Diagram FCTORY ISTLLED DISCOECT (OPTIOL) FCTORY/FIELD ISTLLED MX. DISCOECT TYPE W LIE 00 MPS (0 MPS COTIUOUS) EQUIPMET GROUDIG TERMILS LIE 00 MPS (0 MPS COTIUOUS) FCTORY ISTLLED DISCOECT ODED EUTRL EQUIPMET GROUDIG TERMILS (OPTIOL) FCTORY/FIELD ISTLLED 0 MX. DISCOECT TYPE ODED EUTRL Figure. Type Diagram Figure. Type Diagram Figure. Type Diagram LIE 00 MPS (0 MPS COTIUOUS) FCTORY ISTLLED DISCOECT EQUIPMET GROUDIG TERMILS (OPTIOL) FCTORY/FIELD ISTLLED 0 MX. DISCOECT TYPE LIE FCTORY ISTLLED DISCOECT 00 MPS (0 MPS COTIUOUS) EQUIPMET GROUDIG TERMILS (OPTIOL) FCTORY/FIELD ISTLLED MX. DISCOECT TYPE CSR Type #- WG ODED EUTRL ODED EUTRL #-/0 WG Figure. Type Diagram Figure. Type Diagram # WG - 0 kcmil # WG - 00 kcmil TD.F.0.T.E
21 Meter reakers Technical Data Effective: October Page Dimensions and Knockouts (Type Style House Panels) Dimensions in Inches.00 -/, -/, Knockouts per 0-- ( Required) /, / Knockouts per 0-- ( Required) /, /,, -/ Knockouts per 0- ( Required).0 I.D./I.D. -/, -/,, -/, Knockouts per 0- ( Required).000 ±.0 O.D.. TYP. ±.0 O.D.00 ±.0 -/,, -/, Knockouts Per 0-0. ±.0. ±.0 O.D./O.D.. TYP ±.00 /, / Knockouts Per 0-0 ( required). ±.00. ±.00. ±.0 O.D. -/ (Optional), -/,, -/ Knockouts per 0- ( Required). ±.0 O.D./O.D ±.0 O.D. ±.0. ±.00. ± ±.0 O.D.. ±.00 O.D.. TYP. ±.0 O.D.. TYP. ±.0 O.D.. ± ±.00 TYP..0 ±.00 / (optional), /, -/, -/ Knockouts per 0-0 ( Required). ±.00. ±.00.0 ±.00. ±.00. ±.00. ±.0 O.D.. ±.0 O.D.. ±.00 O.D.. Figure. House Panel Dimensions and Knockouts TD.F.0.T.E
22 Technical Data Page Effective: October Meter reakers Type R Residential 00 mpere and 00 mpere House Panels Type R Residential 00 mpere and 00 mpere House Panels Product Description House Panel is a service entrance device that consists of a meter socket and a distribution section. The unit is rated at 00 amperes or 00 amperes. pplication Description In addition to residential installations, a house panel could also be used for an apartment/condominium, clubhouse or common area. Verify local utility requirements before sale. Features, enefits and Functions 00 mpere and 00 mpere House Panels Underground feed only. RH type hub provisions on bottom endwall. Meets EUSERC requirements. Plug-on 00 ampere meter socket (0 ampere continuous). EM R Rainproof. Lever bypass socket available on certain catalog numbers. Service entrance equipment and UL listed. Uses R branch breakers. Product Selection Table mpere House Panels mpere Rating Security ypass Main reaker (Included) Optional Secondary Main reaker (ot Included) Service Type IC Distribution Type R Diagram Side Main Lugs and eutral Catalog umber Surface Semi Flush less less less less less less less less Lever Lever Lever Lever DK W WH W WH DK W Provision W WH DK W WH WH WH WH WH R R W WH R W W WH W WH RH RH WH WH,000/,000k,000k,000k,000k,000/,000k,000/,000k,000k,000/,000k,000k,000/,000k,000/,000k,000k,000/,000k,000/,000k,000/,000k,000/,000k,000/,000k Confirm security type for individual EUSERC utility requirements. If unit needs to be semi-flush, order accessory item catalog number HPPR to convert all surface mounting devices to semi-flush mounting. Feed-through lugs. olt-on meter socket. Secondary sub-main installed in panel. / /0 0 /0 /0 / /0 /0 /0 0/0 0/0 Landing studs for utility supplied compression lugs. HP0 HP000S HP000SH HP00S HP000SH HP0 HP0S HPP00S HP0S HP0SH HP00 HP00S HP00SH HP0SHL HP000SHL HP0SHL HP000SHL TD.F.0.T.E
23 Meter reakers Technical Data Effective: October Page Typical Diagrams (Type R Style House Panels) FCTORY ISTLLED 00 DISCOECT FCTORY ISTLLED DISCOECT (OPTIOL) FCTORY/FIELD ISTLLED 0 MX. DISCOECT FCTORY ISTLLED 00 DISCOECT 00 MPS (0 MPS COTIUOUS) LIE 00 MPS (0 MPS COTIUOUS) EQUIPMET GROUDIG TERMILS LIE 00 MPS (0 MPS COTIUOUS) 0 EQUIPMET GROUDIG TERMILS 0 LIE ODED EUTRL 0 ODED EUTRL ODED EUTRL Figure. Type R Diagram Figure. Type R Diagram Figure. Type R Diagram FCTORY ISTLLED DISCOECT (OPTIOL) FCTORY/FIELD ISTLLED MX. DISCOECT FCTORY ISTLLED DISCOECT (OPTIOL) FCTORY/FIELD ISTLLED MX. DISCOECT 00 MPS (0 MPS COTIUOUS) FCTORY ISTLLED DISCOECT EQUIPMET GROUDIG TERMILS (OPTIOL) FCTORY/FIELD ISTLLED 0 MX. DISCOECT LIE 00 MPS (0 MPS COTIUOUS) EQUIPMET GROUDIG TERMILS LIE 00 MPS (0 MPS COTIUOUS) EQUIPMET GROUDIG TERMILS LIE ODED EUTRL ODED EUTRL ODED EUTRL Figure. Type R Diagram Figure. Type R Diagram Figure. Type R Diagram Type R #- WG #-/0 WG # WG - 0 kcmil # WG - 00 kcmil TD.F.0.T.E
24 Technical Data Page Effective: October Meter reakers Typical Diagrams (Type R Style House Panels) FCTORY ISTLLED 00 DISCOECT FCTORY ISTLLED DISCOECT (OPTIOL) FCTORY/FIELD ISTLLED 0 MX. DISCOECT LIE 00 MPS (0 MPS COTIUOUS) EQUIPMET GROUDIG TERMILS LIE 00 MPS (0 MPS COTIUOUS) EQUIPMET GROUDIG TERMILS ODED EUTRL ODED EUTRL Figure. Type R Diagram Figure. Type R Diagram Figure. Type R Diagram FCTORY ISTLLED DISCOECT (OPTIOL) FCTORY/FIELD ISTLLED MX. DISCOECT 00 MPS (0 MPS COTIUOUS) LIE EQUIPMET GROUDIG TERMILS FCTORY ISTLLED DISCOECT (OPTIOL) FCTORY/FIELD ISTLLED MX. DISCOECT 0 00 MPS (0 MPS COTIUOUS) EQUIPMET GROUDIG TERMILS 0 LIE ODED EUTRL 0 ODED EUTRL Figure 0. Type R Diagram Figure. Type R Diagram Type R #- WG #-/0 WG # WG - 0 kcmil # WG - 00 kcmil TD.F.0.T.E
25 Meter reakers Technical Data Effective: October Page Dimensions and Knockouts (R Style House Panels) Dimensions in Inches /,, -/, Knockouts / (Optional), /,, -/, -/ ( Required) /, /, Knockouts ( Required) / (Optional), -/,, -/ Knockouts ( Required) Figure. Type R Meter reaker Dimension Drawing Eaton Corporation, ll Rights Reserved TD.F.0.T.E
26 Technical Data Page Effective: October Meter reakers TD.F.0.T.E
27 Meter reakers Technical Data Effective: October Page TD.F.0.T.E
28 Technical Data Page Effective: October Meter reakers TDF0TE TD.F.0.T.E Printed in U.S.. / Z0
HP404040SHL 400A PNL, 200A MCB W/40 Dist & Prov For 200A Main, 2
0 South Street -, TX acogdoches Phone: -- Fax: -0- Catalog umber Manufacturer Description Weight per unit Product Category Features amperage rating dimensions interrupt rating main circuit breaker umber
More informationIllinois and Northwest Indiana Metering Equipment
Illinois and Northwest Indiana Metering Equipment Technical Focus TD00000E Servicing : Ameren UE, Commonwealth Edison, Ameren IP (Illinois Power Utility), Northern Indiana and Public Service (NIPSCO) Illinois
More informationSquare D Meter Centers. A Comprehensive. Selection. Time-Saving, Reliable. Solutions
Square D Meter Centers A Comprehensive Selection of Time-Saving, Reliable Solutions VERSATILITY. DESIGN SUPERIORITY. SELECTION. Installation simplicity. The largest selection of meter centers in the industry.
More information1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.
.2 Loadcenters and Circuit Breakers Overview Product Selection Guide BR Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Short-Circuit Current Rating 0 kaic: All single- and three-phase
More information1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.
.2 Overview Product Selection Guide BR Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Short-Circuit Current Rating 0 kaic: All single- and three-phase loadcenters 70 225 A, 8 to 42
More information1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.
.2 Overview Product Selection Guide BR Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Short-Circuit Current Rating 0 kaic: All single- and three-phase loadcenters 70 225A, 8 to 42
More information1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.
.2 Loadcenters and Circuit Breakers Overview Product Selection Guide BR Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Short-Circuit Current Rating 0 kaic: All single- and three-phase
More informationProduct Selection. Loadcenter Cover U.S. $ Price U.S. $ Size
ebruary 007 Loadcenters & ircuit reakers Type Loadcenters & ircuit reakers Product Selection -15 onvertible Loadcenters M or MLO ase Units and evices 10,000/5,000 mperes Interrupting apacity omplete assembly
More informationSave labor by installing. suppression.
-18 oadcenters & ircuit reakers Type oadcenters & ircuit reakers Type Surge oadcenters ebruary 2007 Product escription Surge Panel The Type Surge oadcenter includes a factory-mounted and wired surge suppressor
More informationSelf Contained - Non-Jaw Clamping Lever Bypass
Self Contained - Non-Jaw Clamping 125 Amp Continuous - 600 VAC Application Single meter position Designed for watt hour meters that meet ANSI C12.10 Overhead or underground feed Surface mount Construction
More informationSelf Contained - Non Lever Bypass
Self Contained - Non 125 & 200 Amp Continuous - 600 VAC Application Single meter position Designed for watt hour meters that meet ANSI C12.10 Overhead or underground feed Surface mount Construction Ringless
More informationCANADIAN CATALOG JANUARY SENTRICITY Loadcentres and Circuit Breakers Raising the standard in residential.
CANADIAN CATALOG JANUARY 208 Loadcentres and Circuit Breakers Raising the standard in residential. 2 S E N T R I C I T Y T M L O A D C E N T R E S A N D C I R C U I T B R E A K E R S - C A N A D I A N
More informationResidential Renovation Loadcenters and Accessories
Residential Renovation Loadcenters and Accessories Product Focus Replaces existing fuse boxes or loadcenters Industry Exclusive Renovation Loadcenter Quick and Clean Installation Designed specifically
More informationC 2 5 D N A A A
Product Family Overview May 007 pplication Description These Cutler-Hammer ampere and horsepower rated devices from Eaton s electrical business are designed for service in applications such as Refrigeration,
More informationMeter Enclosure and Equipment Standards
Meter Enclosure and Equipment Standards (a) (b) General Requirements: CITY OF OCALA UTILITY SERVICES METER ENCLOSURE AND EQUIPMENT STANDARDS: (1) To avoid the costs associated with having to replace unacceptable
More informationThermal-Magnetic / Magnetic Only Molded Case Circuit Breakers Introduction
Thermal-Magnetic / Magnetic Only Molded ase ircuit reakers Introduction Table 8: reakdown of Typical atalog Number L 3 6 050 V 2100 reaker amily Y - mpere rame - 100 mpere rame K - 250 mpere rame L - 400
More informationThis Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount.
This Datasheet for the IC697CHS790 Rack, 9 Slots, Rear Mount. http://www.cimtecautomation.com/parts/p-14771-ic697chs790.aspx Provides the wiring diagrams and installation guidelines for this GE Series
More information60103 Circuit Breaker
6003 Circuit Breaker United States MINIATURE CIRCUIT BREAKER, 20/240VAC, 2A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Circuit Breaker Type: Standard
More informationMARWELL CORPORATION Manufacturer of UL Listed Meter Socket Adapters
Yellow Section Capacitor Sockets and Monitors, Temporary Service Adapters, Quick Set/Gen Set, Temporary Load Center, TSA, Transformer Load Management CAPACITOR CONTROLLER SOCKET Four - Six Jaws Wire Lugs
More informationPower Xpert Branch Circuit Monitor
Technical Data TD150021E Power Xpert ranch ircuit Monitor Introduction The Power Xpert ranch ircuit Monitor (PX M) meter module strip provides SI 12.20 0.5% revenue class branch circuit metering in panelboard
More informationFree-Stand Universal-Cutout Disconnects Type 12 Modular Free-Stand Disconnects and Accessories
763.422.2600 SPEC-00252 N763.422.2211 DISCONNECT FREE-STAND UNIVERSAL-CUTOUT DISCONNECTS TYPE 12 MODULAR FREE-STAND DISCONNECTS AND ACCESSORIES Free-Stand Universal-Cutout Disconnects Type 12 Modular Free-Stand
More informationPanelFAST. Setting a new standard for immediate product availability with Square D Ready to Install (RTI) Panelboards
PanelFAST Setting a new standard for immediate product availability with Square D Ready to Install (RTI) Panelboards Whether you planned ahead or have an unexpected project, why wait? You should expect
More informationBulletin 1494H Heavy Duty Safety Switches
ulletin H Heavy uty Safety isconnect Switches Product Overview/Product Selection Fusible and Non-Fusible Type ulletin H Heavy uty Safety Switches switch ratings Type, R, or enclosures V: -phase, -phase,
More informationMG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD
United States MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD Product Information Features and Specifications For Use With: OEM Panels Approvals: UL
More informationMTA-156 IDC Quad Connectors
MT-156 IDC Quad Connectors MT-156 Product Facts Provides four points of contact Greater current carrying capability than Standard MT-156 Connectors Connector styles include both closed end and feedthru
More informationFree-Stand Universal-Cutout Disconnects Type 12 Modular Free-Stand Disconnects and Accessories
Spec-00252 Free-Stand Universal-Cutout Disconnects Type 12 Modular Free-Stand Disconnects and Accessories Modular Disconnect Enclosure, Type 12 INDUSTRY STANDARDS UL 508A Listed; Type 12; File No. E61997
More information4.3. Switchboards. Contents Description Pow-R-Line Drawout Molded Case Circuit Breaker Switchboards Product Selection...
.3 Product Description Drawout molded case circuit breaker switchboard Front accessible Front connected Through-the-door design drawout mechanism through 600A Insulated case UL 89 breakers up to 200A Visual
More informationFree-Stand Universal-Cutout Disconnects Type 12 Modular Free-Stand Disconnects and Accessories
763.422.2600 Spec-00252 L763.422.2211 Free-Stand Universal-Cutout s Type 12 Modular Free-Stand s and accessories Free-Stand Universal-Cutout s Type 12 Modular Free-Stand s and Accessories Modular Enclosure,
More informationSwitchboards. Product Overview
Switchboards Product Overview A switchboard distributes large electrical current used by electrical equipment and building requirements. Applications can range from a small office building to a major industrial
More information7000 SERIES Power Switching Solutions. Closed Transition Transfer Switching. Delayed Transition Transfer Switching
7000 SERIES Power Switching Solutions Fig. 2: Four pole, Closed Transition Switch rated 1000 Amperes in Type 1 enclosure. Closed Transition Switching Closed Transition Switches feature main contacts that
More informationThe Leviton Load Center THE FUTURE MADE CURRENT
The Leviton Load Center THE FUTURE MADE CURRENT Raising the Bar Again For over 110 years, Leviton has cultivated a rich tradition of safety and innovation, developing electrical products that set the
More information24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD
United States 24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Approvals: IEC 60947-2 Rated
More informationPower Mod. Introduction and Contents. Revised 02/18/14
Introduction and Contents 02/18/14 2 METER Siemens Power Mod is a robust, flexible, and feature-rich line of modular metering designed to exceed today s market demands. Power Mod s exclusive QuickSystem
More informationPower Series Transfer Switch
Power Frame Type Open and Delayed Transition Power Series Transfer Switch 2000-5000 mps Power Series 1 of 5 utomatic Transfer Switch 2000 5000, up to 600V, 50/60 Hz 3 or 4 poles NEM 1 or 3R Open with Inphase
More informationThe City of Winnipeg Dry Type Transformers up to 600 V Primary Section Bid Opportunity No Page 1 of 2
The City of Winnipeg Dry Type Transformers up to 600 V Primary Section 26121601 Bid Opportunity No. 1196-2014 Page 1 of 2 Part 1 General 1.1 RELATED REQUIREMENTS.1 Section 26 05 01 - Common Work Results
More informationSquare D Homeline Load Centers and Circuit Breakers. Engineered for value
Square D Homeline Load Centers and Circuit Breakers Engineered for value TM From the Square D brand you know and trust, Homeline Load Centers are engineered for value, reliability, and innovation. The
More informationHeavy Duty Terminal Blocks
General Information: are available in two styles Deadfront Type (1100, 1200, 985 and 0987 series) and Barrier Type (1500, 1600 and 1700 series). Ratings and Standards: The voltage ratings of terminal blocks
More informationFree-Stand Universal-Cutout Disconnects Free-Stand Type 12 Disconnects
763.422.2600 SPEC-00250 N763.422.2211 DISCONNECT FREE-STAND UNIVERSAL-CUTOUT DISCONNECTS FREE-STAND TYPE 12 DISCONNECTS Free-Stand Universal-Cutout Disconnects Free-Stand Type 12 Disconnects TWO-DOOR WITH
More informationUS 5,634,357 D 385,7683 Bulletin: A21S4
763.422.2600 Spec-00384 H763.422.2211 Free-Stand Stainless Steel Preferred-Cutout s Stainless Steel Two-Door s Free-Stand Stainless Steel Preferred-Cutout s Stainless Steel Two-Door s Two-Door Stainless
More informationUS 5,634,357 D 385,7683 Bulletin: A28S4
763.422.2600 Spec-00385 J763.422.2211 Free-Stand Stainless Steel Preferred-Cutout s Stainless Steel Heavy Duty s Free-Stand Stainless Steel Preferred-Cutout s Stainless Steel Heavy Duty s Stainless Steel
More informationFree-Stand Stainless Steel Preferred-Cutout Disconnects Stainless Steel Two-Door Disconnects US 5,634,357 D 385,7683 BULLETIN: A21S4
763.422.2600 SPEC-00384 J763.422.2211 DISCONNECT FREE-STAND STAINLESS STEEL PREFERRED-CUTOUT DISCONNECTS STAINLESS STEEL TWO-DOOR DISCONNECTS Free-Stand Stainless Steel Preferred-Cutout Disconnects Stainless
More informationPLC Racks IC697CHS782/783
5 1 PLC Racks IC697CHS782/783 (IC697CHS782/783) datasheet Features Accepts 3rd Party VME modules which require 0.8 spacing. Accepts all IC697 PLC module types. Rear mount rack mounts in a 10 (254 mm) deep
More informationArmorConnect Power and Control Media
Selection Guide ArmorConnect Power and Control Media Bulletins 280, 888, 889, 898 2 Bulletin 280, 888, 889, 898 Power Media Product Overview Media Description Features Trunk Cable Cordset - Cable with
More informationFree-Stand Stainless Steel Preferred-Cutout Disconnects Stainless Steel Heavy Duty Disconnects US 5,634,357 D 385,7683 BULLETIN: A28S4
763.422.2600 SPEC-00385 L763.422.2211 DISCONNECT FREE-STAND STAINLESS STEEL PREFERRED-CUTOUT DISCONNECTS STAINLESS STEEL HEAVY DUTY DISCONNECTS Free-Stand Stainless Steel Preferred-Cutout Disconnects Stainless
More informationCROWN CLIP Series Sockets
OWN LIP Series Sockets Product Facts ompact design High performance OWN BND contacts urrents to 350 mps 1 Mates with solid or laminated blades Supports true hot-plug (current interruption)2 Float-mount
More informationApplication Techniques CENTERLINE 2100 Motor Control Centers
POWER SYSTEM CONSIDERATIONS FOR PRODUCT SELECTION Application Techniques CENTERLINE 2100 Motor Control Centers Power System Considerations for Product Selection i Power System Considerations for Product
More informationPower Series Transfer Switch
Service Entrance Rated Power Frame Type losed Transition Power Series Transfer Switch 1000-5000 mps Power Series 1 of 5 utomatic Transfer Switch, 100% Service Entrance Rated 1000 5000, up to 600V, 50/60
More informationDual-Feed 80A Auto Low Voltage Disconnect Panel - 80LVD02
Dual-Feed 80A Auto Low Voltage Disconnect Panel - 80LVD02 User Manual 1.1 Overview Telect s 80A, -48 Vdc Low-Voltage Disconnect (LVD) panel is a rack-mounted component with coil-operated contactors. These
More informationSingle-Phase Encapsulated
Single-Phase Encapsulated 7 50 VA to 25 kva Applications n For general loads, indoors or out, including lighting, industrial and commercial applications n Units may be banked for 3-Phase operations n For
More informationCircuit Breakers NEED
Type BR NEED Product Description The primary function of a circuit breaker is to protect the wire from overheating (referred to as an overload) and fault currents (referred to as short circuits). Circuit
More informationSection 20 Distribution (Underground)
PREVIOUS SEARCH NEXT Section Distribution (Underground) Table of Contents Page Underground Connectors...-2 Padmount Transformer Connectors...-3 Pedestal Connectors...-4 Pedestal Block Connector...-6 Street
More informationI-Line Panelboards. Innovative design, smart bus technology, and simple installation
I-Line Panelboards Innovative design, smart bus technology, and simple installation TM Smart: designed for efficient installation Simple: Efficient Installation Process I-Line Breakers Main Lugs: Fixed-mounted
More informationFT Flexitest Family. Switches, Covers and Test Plugs
FT Flexitest Family Switches, Covers and Test Plugs FT Flexitest Switches Description The flexibility provided by the FT case design evolved into a separate family of molded base test switches for testing
More information920 Remote Control (RC) Switches
920 Remote Control (RC) Switches ASCO is the global leader in power switching and controls ASCO 920 PRODUCT SPECIFICATIONS SWITCH ONLY (PANELBOARD MOUNTING) 1,2,3 () DIMENSIONS, IN.(MM) WIDTH HEIGHT DEPTH
More informationIPaCS Equipment Overview Modular Panelboard System Integrated Power Center Integrated Power Center
Table of Contents Section 0 Integrated Power and Control Solutions (IPaCS) Equipment IPaCS Equipment Overview 0- Modular Panelboard System 0-3 Integrated Power Center 0-3 Standby Power Connection Solutions
More informationSquare D QO Load Centers and Circuit Breakers. The leader for safe, reliable, and innovative solutions
Square D QO Load Centers and Circuit Breakers The leader for safe, reliable, and innovative solutions TM QO Load Centers are built on the Square D reputation for reliability, innovation, and circuit protection
More informationThe Leviton Load Center THE FUTURE MADE CURRENT
The Leviton Load Center THE FUTURE MADE CURRENT Raising the Bar Again For over 110 years, Leviton has cultivated a rich tradition of safety and innovation, developing electrical products that set the
More informationInstallation, Operation, and Service Manual SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET
Technical Publications SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET for ARTIS Q / Q.ZEN / ONE ARTIS ZEEGO / ZEEGO.ZEN ARTIS ZEE MULTIPURPOSE SINGLE PLANE IECAX480V125A Main Disconnect Panel Bevco Engineering
More informationTransfer Switches 5.1 Transfer Switch Equipment Product Selection Guide... Product Description... Application Description...
.1 Transfer Switch Equipment Product Selection Guide.................................... Product Description....................................... Application Description......................................2
More informationFree-Stand Disconnects and Accessories
763.422.2600 Spec-00067 L763.422.2211 Free-Stand Preferred-Cutout s Free-Stand s and Accessories Free-Stand Preferred-Cutout s Free-Stand s and Accessories Free-Stand Enclosure, Type 1 INDUSTRY STANDARDS
More informationSECTION SWITCHBOARDS
SECTION 26 24 13 PART 1 - GENERAL 1.1 SUMMARY A. Work Included: 1. Switchboards 2. Commercial Metering Switchboards 3. Non-Utility Power Meters (Microprocessor-Based Metering Equipment) PART 2 - PRODUCTS
More informationPowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ)
PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ) Catalog Class 0CT00R/0 0 CONTENTS Description..............................................Page Description.............................................
More informationPower Switching & Controls for Business-Critical Continuity
Power Switching & Controls for usiness-critical Continuity 4-hour protection no matter when trouble strikes SCO Series 00 Power Transfer Switches for Power Outage Protection Where would you be without
More informationContents. Volume 5 Motor Control and Protection CA E December
Rotary Disconnects.4 Contents Description Page Product Description............................. 677 Standards and Certifications...................... 677 Product Selection..............................
More informationASCO 920 Remote Control (RC) Switches
Maximum reliability and excellent value ASCO 920 Remote Control (RC) Switches ASCO 920 Remote Control Switch in Type Enclosure The ASCO 920 is designed as a feeder disconnect switch for load capacities
More informationPower Series Transfer Switch
ypass Isolation ontactor Type losed Transition Transfer Switch 100-1200 mps 1 of 5 ypass Isolation Transfer Switch 100 1200, up to 600V, 50/60 Hz 3 or 4 poles NEM 1 or 3R losed Transition UL1008 Listed
More informationMetal-enclosed interrupter 5 kv-15 kv usa.siemens.com/siebreak
SIEREK switchgear Metal-enclosed interrupter 5 kv-15 kv usa.siemens.com/siebreak SIEREK Metal-Enclosed Interrupter Switchgear Selection and pplication Guide SIEREK medium-voltage metal-enclosed interrupter
More informationFree-Stand Type 12 Disconnect Enclosures. Heavy-Duty Free-Stand Disconnect Enclosure, Type 12
Spec-00251 FPH FX (763) 422-2600 422-2211 Disconnect Free-Stand Universal-Cutout Disconnect Enclosures Heavy-Duty Free-Stand Disconnect Enclosure, Type 12 Industry Standards UL 508A Listed; Type 12; File
More informationPower-Style QED-2, Series 2 Low Voltage Switchboards
Power-Style QED-2, Series 2 Low Voltage Switchboards Catalog 2742CT1001 (Addendum to 2742CT9501R12/09) 2010 Class 2742 CONTENTS Description............................................. Page Features...................................................
More informationPower Series Transfer Switch
Power Frame Type losed Transition Power Series Transfer Switch 1600-5000 mps Power Series 1 of 5 utomatic Transfer Switch 1600 5000, up to 600V, 50/60 Hz 3 or 4 poles NEM 1 or 3R losed Transition UL1008
More informationSIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET
Product Data Sheet Technical Publications SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET for ARTIS Q / Q.ZEN / ZEE BIPLANE IECAX480V225A Main Disconnect Panel Bevco Engineering Company, Inc. CONFIDENTIAL
More informationUS CATALOG. SENTRICITY Load Centers and Circuit Breakers Raising the standard in residential.
US CATALOG SENTRICITY Load Centers and Circuit Breakers Raising the standard in residential. 2 SENTRICITY LOAD CENTERS AND CIRCUIT BREAKERS SENTRICITY Residential solution Home has a power like no other.
More informationIndustrial Control. 50 to 5,000 VA. Applications. Specifications. Standards. Options and Accessories. Features, Functions, Benefits.
Industrial Control 6 50 to 5,000 VA Applications n For commercial and industrial control applications including; control panels, conveyor systems, machine tool equipment, pump systems, and commercial air
More informationIndustrial Control. 50 to 5,000 VA. Applications. Specifications. Standards. Options and Accessories. Features, Functions, Benefits.
Industrial Control 6 50 to 5,000 VA Applications n For commercial and industrial control applications including; control panels, conveyor systems, machine tool equipment, pump systems, and commercial air
More informationNCH-1000 (Multiple Breaker Types) Installation Instructions
20M1 12345678 NCH-1000 (Multiple Breaker Types) Installation Instructions DOC. #560502100 C 7/30/04 PRINTED IN U.S.A. Regulatory Compliance Safety This device has been tested and found to be in compliance
More informationSPOS (Station Point of Sale) 200. SFTP (Station Fare Transaction Processor) 35. CQD (Card Query Device) 35. HCR (Handheld Card Reader) Cradles 120
DESIGN GUIDELINES PRESTO INSTALLATION & CONNECTIVITY PAGE 1 of 4 ELECTRICAL CONNECTIVITY AND WIRING Communications Conduits Conduits designated for Presto equipment data wiring shall be clearly identified
More informationSeries CA7 Contactors
Series Rugged, space saving and modular Sprecher + Schuh s newest contactor for applications up to 6HP Over years of design experience has produced Sprecher + Schuh s seventh generation contactor line.
More informationSurge Protection V1-T2-2 V1-T2-2 V1-T2-3 V1-T2-4. Learn Online
Surge Protection Surge Protection Devices.1 Product Description...................................... Application Description.................................... Standards and Certifications................................
More informationThe 400, 800, and 2300 Series, from
400, 800, 2300, 2300D Surface Nonmetallic Raceway Systems For Low Voltage and Power pplications 400, 800, 2300, 2300D Series Raceway Systems The 400, 800, and 2300 Series, from The Wiremold Company, is
More informationPLT. Breaker-based transfer switch open, closed or soft transition amps. Specification sheet
Specification sheet PLT Breaker-based transfer switch open, closed or soft transition 800 3000 amps Description PLT breaker-based transfer switches are designed for operation and switching of electrical
More informationUL 489 DIN rail branch circuit breakers
UL 9 DI rail branch circuit breakers FAZ-A circuit breakers Product Overview UL 9 DI rail branch circuit breakers FAZ-A circuit breakers PRODUCT OVERVIEW Optimum and efficient protection Optimum product
More informationCS XL XM. EcoSystem Bus Supply
EcoSystem An EcoSystem lighting network containing more than one ballast, module, or driver requires an EcoSystem. This supply powers one or two independent EcoSystem buses with up to 64 ballasts or ballast
More informationCooper B-Line RESIDENTIAL SERVICES
RESIDENTIAL SERVICES Approved Voltage Optional Voltage w/utility Approval 011 011 5 th Clip 100 Amp Socket Only, Overhead 011F 011F 5 th Clip 100 Amp Meter Socket & Circuit 1M1R 1M1R 5 th Clip Breaker
More informationPACSystems RX7i IC698CHS009/119
January 2010 The RX7i rack can be used for all RX7i CPU and I/O configurations, Series 90-70 I/O, and VME modules. Backplane connectors are spaced on 0.8" (20.3mm) centers to accommodate single-width RX7i
More informationMaximum Reliability & Excellent Value. Features. UL Listed Withstand & Close-On Ratings. Series 300 Power Transfer Switches
Series 300 Power Transfer Switches Maximum Reliability & Excellent Value With a Series 300 Transfer Switch, you get a product backed by ASCO Power Technologies, the industry leader responsible for virtually
More informationFUSERBLOC UL Fusible disconnect switches UL and CSA 30 to 800 A
Fuse protection The solution for > Motor load break. > Protection of industrial cabinet. > Electrical distribution. ul_004_a Strong points fuser-ul_006_a Function FUSERBLOC UL fusible disconnect switches
More informationFUSERBLOC UL Fusible disconnect switches UL and CSA from 30 to 800 A
Fuse protection The solution for > Motor on-load disconnect > Protection of industrial cabinet > Electrical distribution ul_004_a Strong points fuser-ul_006_a Function FUSERBLOC UL fusible disconnect switches
More information2.) Cabinet setup and preset data shall, as standard, be fully user programmable on a per cabinet or system wide basis.
A21 DIMMER CABINET SPECIFICATION. GENERAL. A.) Overview. 1.) The dimmer cabinets shall be fully digital, designed specifically for architectural and entertainment lighting applications, and shall consist
More informationSPEEDFAX TM 2011 Murray Electrical Products. Contents 3 MURRAY. Residential L Commercial L Industrial
SPEEFX T 2011 urray Electrical Products Siemens would like to welcome the urray Electrical Products into the Speedfax. The urray Electrical Products catalog and Siemens Speedfax has been combined for our
More informationT-Nuts St. Industrial Profile Systems Fasteners. Technical Data. Application. Ordering Information. Catalog /US T-Nuts
atalog 1816-3/US St Standard T-nuts conveniently roll into profile T-slots at any location. The spring/ball locking feature keeps the T-nut in place in vertical applications. Standard mounting elements
More informationFree-Stand Universal-Cutout Disconnects Free-Stand Type 4 Disconnects
Spec-01054 Free-Stand Universal-Cutout Disconnects Free-Stand Type 4 Disconnects Free-Stand Disconnect with Quick-Release Continuous Hinge, Type 4 APPLICATION Simple, heavy-duty with easy door removal
More informationStandard Product One-Door Enclosures. Free-Stand Universal-Cutout Disconnects Free-Stand Type 12 Disconnects
Spec-00251 Free-Stand Universal-Cutout Disconnects Free-Stand Type 12 Disconnects Heavy-Duty Free-Stand Disconnect Enclosure, Type 12 SPECIFICATIONS 11 gauge steel (.121 inch) Seams continuously welded
More informationMULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors
B Curve NC100H Supplementary Protectors Rating 1P 2P 3P 4P 80 MG27164 MG27175 MG27186 MG27197 MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors C Curve NC100H Supplementary Protectors
More informationMULTI 9 System Catalog UL Recognized C60N Supplementary Protectors
UL Recognized C60N Supplementary Protectors B Curve C60N Supplementary Protectors 1 MG24110 MG24125 MG24140 MG24155 15 MG17406 MG17436 MG17461 1.2 MG17402 MG17432 16 MG24118 MG24133 MG24148 MG24163 1.5
More informationC5C Cross-Connect System
C5C Cross-Connect System I N S T A L L A T I O N I N S T R U C T I O N High-Density Connection Blocks 1.0 General Product Information The C5C cross-connect system is comprised of a high-density connection
More informationNon-Fusible Disconnect Switches
UL 98 and IEC, Non-Fused Switches Mersen s non-fusible disconnect switches are listed to UL 98 and bear the CE mark as conformance to IEC 60947-3. They are service entrance devices that are capable of
More informationType NT and Type ZWM Terminal Blocks
Type NT and Type ZWM Terminal Blocks Unit-pole construction Sliding link to permit testing without disturbing wiring High barriers that prevent shorting between poles Class 1E qualified per IEEE RECOGNIZED
More informationCutler-Hammer. January 2001
Cutler-Hammer January 0 Vol.,Ref. 2-2 Product Line Overview January 0 Vol., Ref. No. [068] 2 Product Line Description Cutler-Hammer Molded Case Circuit s are designed to provide circuit protection for
More informationSECTION PANELBOARDS
SECTION 16450 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for panelboards providing fault interrupting capability and overcurrent protective devices. 1.02 REFERENCE STANDARDS A.
More informationSECTION DISCONNECT SWITCHES
SECTION 16440 DISCONNECT SWITCHES PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Division 01 Specification
More information