1 0 South Street -, TX acogdoches Phone: -- Fax: -0- Catalog umber Manufacturer Description Weight per unit Product Category Features amperage rating dimensions interrupt rating main circuit breaker umber of Circuits number of spaces used with Voltage Rating Material, Color, and Finish us Material Descriptions Description Long Description Product Type HP000SHL 00 PL, MC W/0 Dist & Prov For Main, Eaton Corp HP000SHL Eaton Corp Eaton Cutler-Hammer Series Housing Panel, 00, 0/0V, RH/WH Secondary Ciruit, luminum us Material, Lever ypass, ema R Enclosure, Underground Feed Type, Kaic Interrupt Rating, Surface Mounting, less Security, Socket.0 (lbs/each) Residential Meter Socket Circu 00 W.centimetreX.0centimetreX.0decimetre kic CSR 0 lb 0 W Type R breakers 0/0 VC LUMIUM Manufacturer Information rand ETO CUTLER-HMMER GTI 00 Manufacturers Part umber HP000SHL sub brand Cutler-Hammer series UPC Taxonomies, Classifications, and Categories Category Description LODCETERS & COVERS Type Housing panel 00 PL, MC W/0 DIST & PROV FOR MI, Eaton Cutler-Hammer series Housing panel, 00, 0/0V, RH/WH Secondary Ciruit, luminum us Material, Lever bypass, EM R Enclosure, Underground Feed Type, kic Interrupt Rating, Surface mounting, less Security, Socket 00 Housing Panel
2 0 South Street -, TX acogdoches Phone: -- Fax: -0- Packaging Carton Weight Per each Uses, Certifications, and Standards pplication Enclosure Mounting standard POWER DISTRIUTIO EM R Surface mounting UL Listed
3 Meter reakers Technical Data Residential Meter reakers Type Residential Type R Residential Supersedes Technical Data TD.F.0.T.E Pages -, dated ugust Contents Page Residential Meter reakers Residential Meter reakers Product Selection , ox Styles Typical Diagrams Dimensions and Knockouts Type Residential 00 mpere and 00 mpere House Panels Product Selection Typical Diagrams Dimensions and Knockouts Type R Residential 00 mpere and 00 mpere House Panels Product Selection Typical R Diagrams , Dimensions and Knockouts TD000E
4 Technical Data Page Effective: pril Meter reakers Residential Meter reakers Residential Meter reakers Product Description meter breaker is service entrance equipment that consists of a single meter socket and loadcenter (circuit breaker distribution section) or meter socket and main breaker combined in one enclosure. Sometimes called Combos, ll-in-ones, Meter Centers or Meter Mains these units are increasing in popularity as the socket and loadcenter or main breaker are located in one location, thus providing the contractor with a labor and material savings when installing. pplication Description In addition to residential installations, meter breakers are equally applicable for rural service entrance, mobile homes, and construction site temporary power. Meter breakers are most often sold in the western, southwestern and southeastern United States. The popularity of meter breakers is continuing to increase as more utilities deregulate and pass the responsibility of supplying watt-hour meter sockets on to the electrical contractor. pplication Considerations We have the meter breaker to meet your application. Cutler-Hammer offers: on-euserc. EUSERC/West Coast (Electrical Utility Service Equipment Requirements Committee). House Panels. Commercial Safety Sockets. on-euserc The Cutler-Hammer line of on-euserc meter breakers is designed for customers served by utilities that are not members of EUSERC. EUSERC/West Coast The Cutler-Hammer line of EUSERC approved devices adheres to the agreed upon standards. EUSERC utilities are predominately located in the western United States, but some eastern and midwestern utilities are also members. These units can also be used in many on-euserc areas. House Panels Meter breaker device rated at pplied in EUSERC and on-euserc areas. Commercial Safety Sockets pplied in EUSERC and on-euserc service areas and used in commercial applications. Standards and Certifications UL Specification (socket). UL File umber E. EIC-EEI-EM Standards (MSJ-). Meet EUSERC Utility requirements where noted. Documented Seismic Qualified UC and CC Title. UL Specification (panel). Product Specifications Ratings single-phase, -wire, 0/0V C. 0 ampere main breaker and main lug types.,000 amperes rms symmetrical short circuit rating. Features, enefits and Functions oth R and type branch circuit breaker styles available. Meets latest EC wire bending space requirements. Slotted sealing screws at hub with sealing provision provided. Surface units are supplied with mounting tabs. Semi-flush units are supplied with stucco flange. Meter socket ring landing will accept locking security rings. Overhead or underground service. Fifth jaw can be installed in the o clock or o clock position. Semi-flush with nail flange or surface mounting. Meter mounting and underground pull sections are utility sealable. Units are rated a minimum of kic; some units are kic. umerous units supplied with center keyhole for ease of mounting. TD000E
5 Meter reakers Technical Data Effective: pril Page Product Selection Table. Combination Service Entrance Devices (on-euserc) mpere Rating ypass Service kic Jaws Distribution Main ranch reaker Type Style Meter Mains (no distribution section included) OH less Meter Mains (no distribution section included) 0 Horn Horn Style ll-in-ones (includes distribution section) 0 0 / / / / Pole Pole less ll-in-ones (includes distribution section) Horn Horn Horn Horn Horn Horn Horn Horn Horn / / / / / / / / / Pole Pole / / Pole / Pole 0/0 0/0 0/0 0/0 Provision CSR0 CSR0 CSR Provision Provision CSR CSR0 CSR CSR Provision Provision Provision Refer to Distribution CSR0 CSR0 W CSR CSR Main Lugs Main Lugs W W Provision Provision Provision Provision Provision CSR0 CSR Main Lugs Main Lugs Provision Provision Main Lugs CSR Main Lugs W Provision Provision Provision Dimensions & Enclosure Shape See Table on Page for box details. Per installed main breaker rating. Provision for main is provided. WM style devices accept Main reaker style R, -Pole. When a provision for main is provided, order one of the main breakers listed in Table. ll panels are dual labeled to accept Types W or CSR Main reakers. MCK lug kit is needed for load side cable connection for Meter Mains. Please order separately. When a provision for main is provided, order one of the main breakers listed in this table. ll panels are dual labeled to accept Types W, WH and CSR Main reakers. Panels are specifically designed for the Georgia Power Service Territory, but may be used in any service territory that has the same design requirements. Copper bus. One-piece cover on utility side, Florida approved. Single cover design. Will accept maximum four -pole, two -pole, or two quad breakers. Refer to drawing -00. Units come with feed-through lugs. R R R R R R R R R R R R R R R R R R Knockout Catalog umber Page Figure Page Figure / / / / WMR M0TSCR CM0TS MTSCR MPTSCR CMPTS CMTS M0TSC MTS MTSC MPTS MPSD MPTSD WMSC WMSCR CMLTS CM0TS CM0S MTS CMTS CMS MELTS MELTF MTS MTSCU MPTS MPTSCU MPSTD MPTSD MPTSCUD CMTS CMTSD CMLTS CMLTSD CMPTS CMPTSD MLTS CMTS MLTSD MTS MPTS MPSD MPTSD Table. Main reaker Selection Chart Maximum mpere Rating 0 -Pole reaker Catalog umbers kic kic kic W W0 W WH WH0 WH CSR CSR0 CSR Load Side Lug Kit for W MCK and CSR reakers When a provision for main is provided, order one of the main breakers listed in this table. ll panels are dual labeled to accept Types W, WH and CSR Main reakers. TD000E
6 Technical Data Page Effective: pril Meter reakers Table. Combination Service Entrance Devices (EUSERC) mpere Rating ypass Service kic Jaws Distribution Style Meter Mains (no distribution section included) 0 0 / / / / Style ll-in-ones (includes distribution section) OH OH OH OH OH OH OH / / / / / / / / 0/0 / / / / Pole Pole Pole Pole 0/0 0/0 0/0 / 0 0 0/0 / 0/0 / Main MLO MLO W0 CSR0 W CSR MLO MLO Provision R0 R0 0X R0 R R R R X CSR0 CSR0 W0 W0 W0 W CSR W Provision Provision Main Lug Main Lug Main Lug Main Lug W W Provision CSR WH CSR WH CSR W W W CSR ranch Dimensions & reaker Type Enclosure Shape R R See Table on Page for box details. Interrupting rating is dependent on the main breaker that is installed. Unit has copper bus. When a provision for main is provided, order one of the main breakers listed in Table. ll panels are dual labeled to accept Types W or CSR Main reakers. Semi-flush flange, not full stucco flange. Units come with feed-through lugs. Includes factory mounted -/ inch hub on bottom endwall. feed only. Use WM0SMK if second main kit is needed. R R R R R R R R R R R R R R R R R R R R R R R R Knockout Catalog umber Page Fig. Page Fig. Surface Flush ,,,,,,,,,,,, 0,, 0,,,,,,,,,,,,,, 0,, 0,, MELTS CMELTS ME0TS CME0TS METS CMETS MELTS CMELTS MEPTS ME0TS ME0S CME0S ME0TS METS METS MES MES CMES CME0TS CME0S ME0S ME0TS ME0TS METS CMETS METS MEPTSCU MEPTS CMELTS CMELS MELTS MELS METS MES MEPTS CMES ME00SH CMESH ME00TS CMETS METS WM0SL METS CMES MELTF CMELTF ME0TF CME0TF METF CMETF MELTF CMELTF / ME0TF ME0F CME0F ME0TF METF METF MEF MEF CMEF CME0TF CME0F ME0F ME0TF ME0TF METF CMETF METF / / / CMELF / MELF METF MEF MEPTF CMEF / / ME00TF CMETF METF / METF CMEF Table. Main reaker Selection Chart Maximum mpere Rating 0 -Pole reaker Catalog umbers kic kic kic W W0 W WH WH0 WH CSR CSR0 CSR Load Side Lug Kit for W MCK and CSR reakers When a provision for main is provided, order one of the main breakers listed in this table. ll panels are dual labeled to accept Types W, WH and CSR Main reakers. TD000E
7 Meter reakers Technical Data Effective: pril Page ox Styles C D E Figure. Five Different Styles (Shapes) of Product Table. ox Dimensions ox umber Dimensions in Inches (mm) Height Width Depth -/ (.) -/ (0.) -/ (0.) -/ (.) -/ (.) -/ (.) Table. Meter reaker Parts Description -/ (0.) -/ (0.) -/ (.) -/ (.) -/ (0.) -/ (.) -/ (0.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (0.) -/ (.) -/ (.) -/ (.) (.) -/ (.) th Jaw Kits Compact and Standard Styles (M & CM) WM Style Manual ypass Kits Style Units Only (M) Horn ypass Kits less Style Units Only (M & CM) (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) (.) -/ (.) -/ (.) -/ (.) -/ (.) -/ (.) Catalog umber MMJKOP WMJ MMPM MMPH ox Style C C C C D E Table. Wire Size Chart Main Wire Size Range Cu/l 0ºC or ºC for Terminals R0 R0 R0 R0 R0 R0 W W0 W WH WH0 WH CSR CSR0 CSR Main Lugs Main Lugs MCK # kcmil # /0 kcmil # /0 kcmil # /0 kcmil # /0 kcmil # /0 kcmil # 00 kcmil # 00 kcmil # 00 kcmil # 00 kcmil # 00 kcmil # 00 kcmil #/0 0 kcmil #/0 0 kcmil #/0 0 kcmil Table. Wire Size is Determined by the Circuit reaker Installed in the Enclosure. Maximum Wire Size and mpere Rating is Determined as Follows: Wire/pplication # 00 kcmil luminum Standard luminum Service Entrance Copper Standard and Service Entrance Maximum Wire Size 0 kcmil 0 kcmil 0 kcmil mpere Rating Table. Hub Selection Chart Hub Size Dimensions in Inches (mm) (.) -/ (.) -/ (.) (0.) -/ (.) (.) Catalog umber DS0H DSH DS0H DSH DS0H DS00H TD000E
8 Technical Data Page Effective: pril Meter reakers Typical Diagrams (Residential Meter reakers) onded eutral onded eutral 0 Service Disconnect Type CSR #- WG #- WG #-/0 WG #-0 WG Figure. Catalog umbers CMES, CMEF, CME0S and CME0F #- WG #-/0 WG #-0 WG Figure. Catalog umbers CMS, CME0S, CME0F, CMES, CMEF, CMES, CMEF and CM0S onded eutral onded eutral #- WG #-/0 WG #-0 WG Figure. Catalog umbers CMELS and CMELF TD000E
9 Meter reakers Technical Data Effective: pril Page Typical Diagrams (Residential Meter reakers) Install Maximum Service Disconnect Type CSR ➀ onded eutral onded eutral onded eutral #-/0 WG #- WG #-0 WG Figure. Catalog umbers CMPTS, CM0TS, CMTS, CME0TF, CME0TS, CMETF and CMETS Factory installed MCK Kit for C/ load lugs. #-/0 WG #- WG #-/0 WG #-0 WG Figure. Catalog umbers CMELTS, CMELTF and CMLTS #- WG #-/0 WG #-0 WG Figure. Catalog umbers CMELTS and CMELTF Service Disconnect Type CSR Maximum Main #-/0 WG #- WG #-/0 WG #-0 WG #-00 WG onded eutral 0 #- WG #-/0 WG #-/0 WG #-0 WG Figure. Catalog umbers CMETS, CMETF, CMTS, CM0TS, CME0TS and CME0TF Figure. Catalog umbers ME0TS, ME0TF, METS and METF TD000E
10 Technical Data Page Effective: pril Meter reakers Typical Diagrams (Residential Meter reakers) onded eutral onded eutral onded eutral onded eutral 0 Disconnect Type W, WH or CSR #- WG #-/0 WG #-0 WG #- WG #-/0 WG #-0 WG #- WG #-/0 WG #-0 WG Figure. Catalog umbers ME0S, ME0F, MES and MEF Figure. Catalog umbers ME0S, ME0F, MES and MEF Figure. Catalog umbers MELS and MELF Service Disconnect #- WG #-/0 WG #-0 WG Figure. Catalog umbers MES and MEF TD000E
11 Meter reakers Technical Data Effective: pril Page Typical Diagrams (Residential Meter reakers) Maximum Service Disconnect Type W, WH or CSR Maximum Service Disconnect Type W, WH or CSR eutral MCK Kit for C/ Load Lugs L L onded eutral onded eutral #-/0 WG #- WG #-/0 WG #-0 WG Figure. Catalog umbers MELTS and MELTF #-/0 WG #- WG #-/0 WG #-0 WG Figure. Catalog umbers ME0TS, ME0TF, METS, METF and MTS #-/0 WG #-/0 WG #-0 WG Figure. Catalog umbers MEPTS, METS, METF, ME0TS and ME0TF Maximum Service Disconnect Type W, WH or CSR eutral #-/0 WG #- WG #-/0 WG #-0 WG Figure. Catalog umbers MELTS and MELTF #-/0 WG #- WG #-/0 WG #-0 WG Figure. Catalog umbers METS, METF, ME0TS and ME0TF TD000E
12 Technical Data Page Effective: pril Meter reakers Typical Diagrams (Residential Meter reakers) onded eutral onded eutral Maximum Service Disconnect Type W, WH or CSR onded eutral #- WG #-0 kcmil #-/0 WG #-00 kcmil #-00 kcmil Figure. Catalog umbers MEPTS and MEPTSCU #- WG #-0 kcmil #-/0 WG #-00 kcmil Figure. Catalog umber MELTS #- WG #-0 kcmil #-/0 WG #-00 kcmil Figure. Catalog umber CMELTS onded eutral Maximum Service Disconnect Type W, WH or CSR LIE onded eutral #- WG #-0 kcmil #-/0 WG #- WG #-0 kcmil #-/0 WG Figure 0. Catalog umbers MEPTS, MEPTF, METS and METF Figure. Catalog umbers MELTS and MELTF TD000E
13 Meter reakers Technical Data Effective: pril Page Typical Diagrams (Residential Meter reakers) TH Jaw Factory Installed on CMTSD and CMPTSD Only onded eutral onded eutral th Jaw Factory Installed on CMLTSD Only onded eutral Ground ar Maximum Service Disconnect Type CSR #- WG #-0 kcmil #-/0 WG #-00 kcmil #-00 kcmil #-/0 WG #-0 kcmil #-00 kcmil #- WG #-0 kcmil #-/0 WG #-00 kcmil Figure. Catalog umbers CMPTSD and CMPTS Figure. Catalog umbers MLTS and MLTSD Figure. Catalog umbers CMLTSD and CMLTS th Jaw Factory Installed on CMTSD and CMPTSD Only onded eutral onded eutral Maximum Service Disconnect Type CSR Maximum Service Disconnect Type CSR #- WG #-0 kcmil #-/0 WG #-00 kcmil #-00 kcmil 0 #- WG #-0 kcmil #-/0 WG #-00 kcmil Figure. Catalog umbers CMTS and CMTSD Figure. Catalog umber CMTS TD000E
14 Technical Data Meter reakers Page Effective: pril Typical Diagrams (Residential Meter reakers) Factory Installed Service Disconnect Type CSR Factory Installed Service Disconnect Type W #- WG #-/0 WG # WG-0 kcmil onded eutral #- WG #-/0 WG # WG-0 kcmil onded eutral Figure. Catalog umbers CMESH, CMETS and CMETF Figure 0. Catalog umbers ME00TF, ME00TS and ME00SH TD000E
15 Meter reakers Technical Data Effective: pril Page Typical Diagrams (on-euserc Meter reaker Design) Included in M0TSCR Maximum Service Disconnect Type CSR onded eutral Maximum Service onded eutral Maximum Service Disconnect Type R, or RH Type W, onded eutral #-/0 WG #-0 kcmil #-0 kcmil #-00 kcmil #- WG #-0 kcmil #-/0 WG #-00 kcmil #-00 kcmil Equipment Ground 0 #- WG #-/0 WG #-0 kcmil Figure. Catalog umbers M0TSC, M0TSCR, MTSCR, MPTSCR and MTSC Figure. Catalog umbers MPSTD, MTS, MTSCU, MPTS, MPTSCU, MPTSD and MPTSCUD Figure. Catalog umbers METS, METF, ME0TS and ME0TF onded eutral Maximum Service Disconnect Type W, WH or CSR ➀ onded eutral Maximum Service Disconnect Type W, WH or CSR 0 #-/0 WG #-0 kcmil #-00 kcmil #-00 kcmil 0 0 #- WG #-0 kcmil #-/0 WG Figure. Catalog umbers MPSD, MTS, MPTS and MPTSD Use MCK for C/ Load Lugs. Figure. Catalog umbers MPSD, MTS, MPTS and MPTSD TD000E
16 Technical Data Page Effective: pril Meter reakers Dimensions and Knockouts (Residential Meter reakers) Dimensions in Inches (mm) Keyhole Knockouts on Sides for Stucco Units Only. -/ (.) -/ (.) Top Stucco Top Surface -/ (.) -/ (.) ottom ottom Figure. Knockouts for Stucco and Surface Units Catalog umbers CME0F, CMEF, CMEF, CME0F, CMEF, CMELF, MEF, ME0F, ME0F, MEF, MELF, MELTF and MEF Table. Top Endwall (Surface) Hub Provision Figure. Knockouts for Stucco and Surface Units Catalog umbers CME0S, CMES, CMES, CME0S, CMES, CMELS, MES, ME0S, ME0S, MES, MELS, MELTS, MES, CM0S and CMS Table. ottom Endwall Knockout Size (Dimensions in Inches) Quantity DS0H DSH DS0H DSH DS0H DS00H DS00P (dapter Plate if using DS H hubs only) Use when DS H Type, -/ and -/-inch hubs are needed. /, /, / /, /,, -/, -/, -/, -/,, -/, Table. Top Endwall (Stucco) Knockout Size (Dimensions in Inches) -/, -/,, -/, -/, -/ /, /, /, / / Quantity TD000E
17 Meter reakers Technical Data Effective: pril Page Dimensions and Knockouts (Residential Meter reakers) Dimensions in Inches (mm) Keyhole Knockouts on Sides for Stucco Units Only. -/ (.) -/ (.) Top Stucco Top Surface -/ (.) -/ (.) Figure. Knockouts for Stucco and Surface Units Catalog umbers CMELTF, CMELTF, CMETF, CME0TF, CME0TF, CMETF, MELTF, MELTF, ME0TF, METF, ME0TF, METF, ME0TF, METF, ME0TF and METF Table. Top Endwall (Surface) Hub Provision ottom Figure. Knockouts for Stucco and Surface Units Catalog umbers CM0TS, CMTS, CMELTS, CMLTS, CMELTS, CMETS, CME0TS, CME0TS, CMETS, CMPTS, MELTS, MELTS, ME0TS, METS, ME0TS, METS, ME0TS, METS, MEPTS, ME0TS, METS, CM0TS, CMTS and MTS Table. ottom Endwall Knockout Size (Dimensions in Inches) ottom Quantity DS0H DSH DS0H DSH DS0H DS00H DS00P (dapter Plate) Use when DS H Type, -/ and -/-inch hubs are needed. / /, / /, /,, -/, -/, -/, -/,, -/, Table. Top Endwall (Stucco) Knockout Size (Dimensions in Inches) -/, -/,, -/, -/, -/ /, /, /, / / Quantity TD000E
18 Technical Data Page Effective: pril Meter reakers Dimensions and Knockouts (Residential Meter reakers) Dimensions in Inches (mm) Keyhole Knockouts on Sides for Stucco Units Only. -/ (.) -/ (.) Top Stucco Top Surface -/ (.) -/ (.) ottom ottom Figure 0. Knockouts for Stucco and Surface Units Catalog umbers ME0TF, METF, METF and MEPTF Table. Top Endwall (Surface) Hub Provision Figure. Knockouts for Stucco and Surface Units Catalog umbers ME0TS, METS, MEPTS, MEPTSCU, METS, MEPTS, MELTS, CMELTS, CMPTS, CMPTSD, CMTS, CMTSD, MLTS, MLTSD, CMLTS and CMLTSD Table. ottom Endwall Knockout Size (Dimensions in Inches) Quantity DS0H DSH DS0H DSH DS0H DS00H DS00P (dapter Plate) Use when DS H Type, -/ and -/-inch hubs are needed. / /, / /, /,, -/, -/, -/, -/,, -/, Table. Top Endwall (Stucco) Knockout Size (Dimensions in Inches) -/, -/,, -/, -/, -/ /, /, /, / / Quantity TD000E
19 Meter reakers Technical Data Effective: pril Page Dimensions and Knockouts (Residential Meter reakers) Dimensions in Inches (mm) -/ (.) Top Flush CMETF ME00TF -/ (.) -/ (.) Top Surface Top Surface -/-inch Hub -/ (.) -/ (.) ottom ottom CMETS ME00TS CMESH ME00SH Figure. Knockouts for Stucco and Surface Units Table. Top Endwall (Surface) Table 0. Top Endwall (Stucco) Table. ottom Endwall Hub Provision Knockout Size (Dimensions in Inches) Quantity Knockout Size (Dimensions in Inches) Quantity DS0H DSH DS0H DSH DS0H DS00H DS00P (dapter Plate) Use when DS H Type, -/ and -/-inch hubs are needed. -/, -/,, -/ /, / /, / /, /,, -/, -/, -/,, -/, -/, -/,, -/, TD000E
20 Technical Data Page Effective: pril Meter reakers Dimensions and Knockouts (on-euserc Meter reaker Design) Dimensions in Inches (mm) -/ (.) -/ (.) Top Surface Top Surface (Catalog umbers with SC and SCR Suffix Only) -/ (.) -/ (.) ottom ottom Figure. Knockouts for on-euserc Units Catalog umbers MPTSD, MTS, MPTS, MPTS, MPTSCU, MTS, MPTSD, MTSCU, MTSD, MPTS, MTS, MPTSD, MPSD, MPSTD, MPTSCUD and MPSD Table. Top Endwall (Surface) Hub Provision Figure. Knockouts for on-euserc Units Catalog umbers CMTS, M0TSCR, MTSCR, MPTSCR, M0TSC and MTSC Table. ottom Endwall Knockout Size (Dimensions in Inches) Quantity DS0H DSH DS0H DSH DS0H DS00H DS00P (dapter Plate) Use when DS H Type, -/ and -/-inch hubs are needed. / / /, / /, -/, -/,, -/ -/,, -/, TD000E
21 Meter reakers Technical Data Effective: pril Page Type Residential 00 mpere and 00 mpere House Panels Type Residential 00 mpere and 00 mpere House Panels Product Description House Panel is a service entrance device that consists of a meter socket and a distribution section. The unit is rated at 00 amperes or 00 amperes. pplication Description In addition to residential installations, a house panel could also be used for an apartment/condominium, clubhouse or common area. Features, enefits and Functions 00 mpere and 00 mpere House Panels Underground feed only. DS_H type hub provisions on bottom endwall. Style Units meet EUSERC requirements. Plug-on 00 ampere meter socket (0 ampere continuous). EM R rainproof. Lever bypass socket available on certain catalog numbers. Service entrance equipment and UL listed. Uses branch breakers. ox type lug kit available HPLK0. Product Selection Table mpere House Panels mpere Rating Security ypass Main reaker (Included) Optional Main reaker (ot Included) Service Type kic Distribution Diagram Side Catalog umber Page Figure Main Lugs Surface Semi-Flush and eutral less less less less Lever Lever Lever Lever W W CSR CSR W W CSR CSR Provision CSR CSR W CSR CSR CSR CSR CSR Confirm security type for individual EUSERC utility requirements. Semi-Flush Flange kit HPPR. If manual bypass is needed, order bypass kit HPPK. Feed-through lugs included. / / / / / / / / / Landing studs for utility supplied compression lugs. CG0S CG0S CG0SHL CG0SHL CG0S CG0S CG0SH CG0SH CGP00S CG0SHL CG0SHL TD000E
22 Technical Data Page 0 Effective: pril Meter reakers Technical Data and Specifications Typical Diagrams (Type Style House Panels) LIE 00 MPS (0 MPS COTIUOUS) FCTORY ISTLLED DISCOECT ODED EUTRL EQUIPMET GROUDIG TERMILS (OPTIOL) FCTORY/FIELD ISTLLED 0 MX. DISCOECT TYPE Figure. Type Diagram Catalog umber CG0SHL LIE 00 MPS (0 MPS COTIUOUS) FCTORY ISTLLED DISCOECT ODED EUTRL EQUIPMET GROUDIG TERMILS (OPTIOL) FCTORY/FIELD ISTLLED MX. DISCOECT TYPE W Figure. Type Diagram Catalog umbers CG0S, CG0SH and CG0SHL LIE 00 MPS (0 MPS COTIUOUS) FCTORY ISTLLED DISCOECT EQUIPMET GROUDIG TERMILS (OPTIOL) FCTORY/FIELD ISTLLED 0 MX. DISCOECT TYPE FCTORY ISTLLED DISCOECT (OPTIOL) FCTORY/FIELD ISTLLED MX. DISCOECT TYPE W ODED EUTRL LIE 00 MPS (0 MPS COTIUOUS) EQUIPMET GROUDIG TERMILS FCTORY ISTLLED DISCOECT (OPTIOL) FCTORY/FIELD ISTLLED 0 MX. DISCOECT TYPE Figure. Type Diagram Catalog umber CG0S LIE 00 MPS (0 MPS COTIUOUS) EQUIPMET GROUDIG TERMILS ODED EUTRL ODED EUTRL Figure. Type Diagram Catalog umbers CG0S and CG0SH Figure. Type Diagram Catalog umber CG0S FCTORY ISTLLED DISCOECT (OPTIOL) FCTORY/FIELD ISTLLED 0 MX. DISCOECT TYPE FCTORY ISTLLED DISCOECT (OPTIOL) FCTORY/FIELD ISTLLED MX. DISCOECT TYPE CSR LIE 00 MPS (0 MPS COTIUOUS) EQUIPMET GROUDIG TERMILS LIE 00 MPS (0 MPS COTIUOUS) EQUIPMET GROUDIG TERMILS Figure. Type Diagram Catalog umber CGP00S #-ÿwg #-/0ÿWG #ÿ WGÿ Ðÿ 0ÿ kcmil #ÿ WGÿ Ðÿ 00ÿ kcmil ODED EUTRL ODED EUTRL Figure. Type Diagram Catalog umber CG0SHL Figure 0. Type Diagram Catalog umber CG0SHL Figure. Type TD000E
23 Meter reakers Technical Data Effective: pril Page Dimensions and Knockouts (Type Style House Panels) Dimensions in Inches.00 -/, -/, Knockouts per 0-- ( Required) /, / Knockouts per 0-- ( Required) /, /,, -/ Knockouts per 0- ( Required).0 I.D./I.D. -/, -/,, -/, Knockouts per 0- ( Required).000 ±.0 O.D.. TYP. ±.0 O.D.00 ±.0 -/,, -/, Knockouts Per 0-0. ±.0. ±.0 O.D./O.D.. TYP ±.00 /, / Knockouts Per 0-0 ( required). ±.00. ±.00. ±.0 O.D. -/ (Optional), -/,, -/ Knockouts per 0- ( Required). ±.0 O.D./O.D ±.0 O.D. ±.0. ±.00. ± ±.0 O.D.. ±.00 O.D.. TYP. ±.0 O.D.. TYP. ±.0 O.D.. ± ±.00 TYP..0 ±.00 / (optional), /, -/, -/ Knockouts per 0-0 ( Required). ±.00. ±.00.0 ±.00. ±.00. ±.00. ±.0 O.D.. ±.0 O.D.. ±.00 O.D.. Figure. House Panel Dimensions and Knockouts TD000E
24 Technical Data Page Effective: pril Meter reakers Type R Residential 00 mpere and 00 mpere House Panels Type R Residential 00 mpere and 00 mpere House Panels Product Selection Table mpere House Panels mpere Rating Security ypass Main reaker less less less less less less less Manual Manual Manual Lever Lever Manual Manual Manual Manual Lever Lever W W WH WH W W WH WH DK W WH DK Provision W WH WH DK W W DK W WH WH WH Product Description House Panel is a service entrance device that consists of a meter socket and a distribution section. The unit is rated at 00 amperes or 00 amperes. pplication Description In addition to residential installations, a house panel could also be used for an apartment/condominium, clubhouse or common area. Features, enefits and Functions 00 mpere and 00 mpere House Panels Underground feed only. DS_H type hub provisions on bottom endwall. Style Units meet EUSERC requirements. Plug-on 00 ampere meter socket (0 ampere continuous). EM R rainproof. Lever bypass socket available on certain catalog numbers. Service entrance equipment and UL listed. Uses R branch breakers. ox Type lug kit available HPLK0. Confirm security type for individual EUSERC utility requirements. Included in all of the following devices. If unit needs to be semi-flush, order accessory item catalog number HPPR to convert all surface mounting devices to semi-flush mounting. Includes manual bypass and additional ground lug to meet evada Power requirements. Secondary sub-main installed in panel. Feed-through lugs included. olt-on meter socket. Optional Secondary Main reaker (ot Included) R R R R R RH RH W WH W W WH WH W W W WH WH WH Service Type kic Dist. Diagram Side Catalog umber Page Figure Main Lugs Surface Semi-Flush and eutral / / / / / / / / / / / /0 0/0 0/0 0/0 0/0 / /0 0/0 / 0/0 / /0 /0 /0 /0 0/ Lug landings for compression lugs HP00S HP0S HP000SH HP000SH HP0S HP000S HP0SHL HP000SHL HP0 HP00S HP000SH HP0 HPP00S HP0S HP0SH HP000SH HP0 HP0 HP00S HP00 HP00S HP00SH HP0SHL HP000SHL TD000E
25 Meter reakers Technical Data Effective: pril Page Typical Diagrams (Type R Style House Panels) LIE FCTORY ISTLLED 00 DISCOECT 00 MPS (0 MPS COTIUOUS) ODED EUTRL Figure. Type R Diagram Catalog umbers HP0 and HP0 LIE FCTORY ISTLLED DISCOECT 00 MPS (0 MPS COTIUOUS) EQUIPMET GROUDIG TERMILS (OPTIOL) FCTORY/FIELD ISTLLED MX. DISCOECT LIE 00 MPS (0 MPS COTIUOUS) FCTORY ISTLLED DISCOECT EQUIPMET GROUDIG TERMILS (OPTIOL) FCTORY/FIELD ISTLLED MX. DISCOECT ODED EUTRL ODED EUTRL FCTORY ISTLLED DISCOECT (OPTIOL) FCTORY/FIELD ISTLLED 0 MX. DISCOECT Figure. Type R Diagram Catalog umbers HP00S, HP000SH, HP000SH and HP00S Figure 0. Type R Diagram Catalog umbers HP000SH, HP000SH and HP000S LIE 00 MPS (0 MPS COTIUOUS) EQUIPMET GROUDIG TERMILS FCTORY ISTLLED DISCOECT (OPTIOL) FCTORY/FIELD ISTLLED 0 MX. DISCOECT ODED EUTRL Figure. Type R Diagram Catalog umbers HP0S, HP0S and HP0SHL LIE FCTORY ISTLLED 00 DISCOECT 00 MPS (0 MPS COTIUOUS) EQUIPMET GROUDIG TERMILS LIE 00 MPS (0 MPS COTIUOUS) Figure. Type R Diagram Catalog umber HP000SHL ODED EUTRL EQUIPMET GROUDIG TERMILS Figure. Type R Diagram Catalog umber HPP00S #-ÿwg #-/0ÿWG ODED EUTRL #ÿ WGÿ Ðÿ 0ÿ kcmil Figure. Type R Diagram Catalog umber HP00 #ÿ WGÿ Ðÿ 00ÿ kcmil Figure. Type R TD000E
26 Technical Data Page Effective: pril Meter reakers Typical Diagrams (Type R Style House Panels) FCTORY ISTLLED 00 DISCOECT FCTORY ISTLLED DISCOECT (OPTIOL) FCTORY/FIELD ISTLLED MX. DISCOECT LIE 00 MPS (0 MPS COTIUOUS) EQUIPMET GROUDIG TERMILS LIE 00 MPS (0 MPS COTIUOUS) 0 EQUIPMET GROUDIG TERMILS 00 MPS (0 MPS COTIUOUS) FCTORY ISTLLED DISCOECT EQUIPMET GROUDIG TERMILS (OPTIOL) FCTORY/FIELD ISTLLED MX. DISCOECT 0 LIE ODED EUTRL 0 ODED EUTRL ODED EUTRL Figure. Type R Diagram Catalog umbers HP00S and HP00SH Figure. Type R Diagram Catalog umber HP000SHL Figure. Type R Diagram Catalog umbers HP0S, HP0SH and HP0SHL FCTORY ISTLLED 00 DISCOECT FCTORY ISTLLED DISCOECT (OPTIOL) FCTORY/FIELD ISTLLED 0 MX. DISCOECT LIE 00 MPS (0 MPS COTIUOUS) EQUIPMET GROUDIG TERMILS LIE 00 MPS (0 MPS COTIUOUS) EQUIPMET GROUDIG TERMILS #-ÿwg #-/0ÿWG #ÿ WGÿ Ðÿ 0ÿ kcmil #ÿ WGÿ Ðÿ 00ÿ kcmil ODED EUTRL ODED EUTRL Figure. Type R Diagram Catalog umber HP0 Figure. Type R Diagram Catalog umber HP00S Figure. Type R TD000E
27 Meter reakers Technical Data Effective: pril Page Dimensions and Knockouts (R Style House Panels) Dimensions in Inches /,, -/, Knockouts / (Optional), /,, -/, -/ ( Required) /, /, Knockouts ( Required) / (Optional), -/,, -/ Knockouts ( Required) Figure. Type R Meter reaker Dimension Drawing TD000E
28 Technical Data Page Effective: pril Meter reakers This page intentionally left blank. TD000E
29 Meter reakers Technical Data Effective: pril Page This page intentionally left blank. TD000E
30 Technical Data Page Effective: pril Meter reakers Eaton Corporation Cutler-Hammer business unit 00 Cherrington Parkway Moon Township, P - US tel: Eaton Corporation ll Rights Reserved Printed in US Publication o. TD000E pril
Meter Breakers. Technical Data. Contents
Technical Data Effective: October Page ew Information Meter reakers Contents Description Page Residential Meter reakers Residential Meter reakers...................................... Product Selection..............................................,
More informationIllinois and Northwest Indiana Metering Equipment
Illinois and Northwest Indiana Metering Equipment Technical Focus TD00000E Servicing : Ameren UE, Commonwealth Edison, Ameren IP (Illinois Power Utility), Northern Indiana and Public Service (NIPSCO) Illinois
More information1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.
.2 Loadcenters and Circuit Breakers Overview Product Selection Guide BR Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Short-Circuit Current Rating 0 kaic: All single- and three-phase
More informationSquare D Meter Centers. A Comprehensive. Selection. Time-Saving, Reliable. Solutions
Square D Meter Centers A Comprehensive Selection of Time-Saving, Reliable Solutions VERSATILITY. DESIGN SUPERIORITY. SELECTION. Installation simplicity. The largest selection of meter centers in the industry.
More information1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.
.2 Overview Product Selection Guide BR Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Short-Circuit Current Rating 0 kaic: All single- and three-phase loadcenters 70 225 A, 8 to 42
More information1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.
.2 Overview Product Selection Guide BR Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Short-Circuit Current Rating 0 kaic: All single- and three-phase loadcenters 70 225A, 8 to 42
More informationResidential Renovation Loadcenters and Accessories
Residential Renovation Loadcenters and Accessories Product Focus Replaces existing fuse boxes or loadcenters Industry Exclusive Renovation Loadcenter Quick and Clean Installation Designed specifically
More information1.2. Loadcenters and Circuit Breakers. Contents. Overview. Type BR Loadcenters and Circuit Breakers. Product Selection Guide.
.2 Loadcenters and Circuit Breakers Overview Product Selection Guide BR Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Short-Circuit Current Rating 0 kaic: All single- and three-phase
More informationProduct Selection. Loadcenter Cover U.S. $ Price U.S. $ Size
ebruary 007 Loadcenters & ircuit reakers Type Loadcenters & ircuit reakers Product Selection -15 onvertible Loadcenters M or MLO ase Units and evices 10,000/5,000 mperes Interrupting apacity omplete assembly
More informationPower Xpert Branch Circuit Monitor
Technical Data TD150021E Power Xpert ranch ircuit Monitor Introduction The Power Xpert ranch ircuit Monitor (PX M) meter module strip provides SI 12.20 0.5% revenue class branch circuit metering in panelboard
More informationSelf Contained - Non Lever Bypass
Self Contained - Non 125 & 200 Amp Continuous - 600 VAC Application Single meter position Designed for watt hour meters that meet ANSI C12.10 Overhead or underground feed Surface mount Construction Ringless
More informationTaxonomies, Classifications, and Categories Category Description PANELBOARD BRANCH BREAKERS V Molded case circuit breaker
4 South Street 7964-76, TX Nacogdoches Phone: 96-69-794 Fax: 96--468 GHB00 P 0A 77/4V Breaker Eaton Corp Catalog Number Manufacturer Description Weight per unit Product Category Features amperage rating
More informationSave labor by installing. suppression.
-18 oadcenters & ircuit reakers Type oadcenters & ircuit reakers Type Surge oadcenters ebruary 2007 Product escription Surge Panel The Type Surge oadcenter includes a factory-mounted and wired surge suppressor
More informationSelf Contained - Non-Jaw Clamping Lever Bypass
Self Contained - Non-Jaw Clamping 125 Amp Continuous - 600 VAC Application Single meter position Designed for watt hour meters that meet ANSI C12.10 Overhead or underground feed Surface mount Construction
More informationDS185 1G FS Box Switch Cover. Features. Description. Manufacturer Information EATON CROUSE-HINDS SERIES GTIN
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 DS185 1G FS Box Switch Cover Cooper Crouse-Hinds Catalog Number Manufacturer Description Weight per unit Product Category
More informationCANADIAN CATALOG JANUARY SENTRICITY Loadcentres and Circuit Breakers Raising the standard in residential.
CANADIAN CATALOG JANUARY 208 Loadcentres and Circuit Breakers Raising the standard in residential. 2 S E N T R I C I T Y T M L O A D C E N T R E S A N D C I R C U I T B R E A K E R S - C A N A D I A N
More informationPanelFAST. Setting a new standard for immediate product availability with Square D Ready to Install (RTI) Panelboards
PanelFAST Setting a new standard for immediate product availability with Square D Ready to Install (RTI) Panelboards Whether you planned ahead or have an unexpected project, why wait? You should expect
More informationQuicklag Industrial Ground Fault Thermal-Magnetic Circuit Breaker, Single-Pole, 30 Ma Trip Sensitivity, 30A, 10 Kaic, 120V, Bolt-On Mounting
4 South Street 7964-76, TX Nacogdoches Phone: 96-69-794 Fax: 96--468 Catalog Number Manufacturer Description Weight per unit Product Category Features amperage rating interrupt rating Poles Trip Voltage
More informationC 2 5 D N A A A
Product Family Overview May 007 pplication Description These Cutler-Hammer ampere and horsepower rated devices from Eaton s electrical business are designed for service in applications such as Refrigeration,
More information3630P Encl 34X28 Enclosure Panel. Features. Material, Color, and Finish. Dimensions and Weight. Descriptions
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 3630P Encl 34X28 Enclosure Panel Cooper B-Line/Cable Tray Manufacturer Weight per unit Product Category Features Material
More information25DTP4DG Tele Power Pole. Features Made in USA. Material, Color, and Finish. Dimensions and Weight
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 25DTP4DG Tele Power Pole Wiremold/Legrand Catalog Number Manufacturer Description Weight per unit Product Category 25DTP4DG
More informationBulletin 1494H Heavy Duty Safety Switches
ulletin H Heavy uty Safety isconnect Switches Product Overview/Product Selection Fusible and Non-Fusible Type ulletin H Heavy uty Safety Switches switch ratings Type, R, or enclosures V: -phase, -phase,
More informationFree-Stand Universal-Cutout Disconnects Type 12 Modular Free-Stand Disconnects and Accessories
763.422.2600 SPEC-00252 N763.422.2211 DISCONNECT FREE-STAND UNIVERSAL-CUTOUT DISCONNECTS TYPE 12 MODULAR FREE-STAND DISCONNECTS AND ACCESSORIES Free-Stand Universal-Cutout Disconnects Type 12 Modular Free-Stand
More informationMeter Enclosure and Equipment Standards
Meter Enclosure and Equipment Standards (a) (b) General Requirements: CITY OF OCALA UTILITY SERVICES METER ENCLOSURE AND EQUIPMENT STANDARDS: (1) To avoid the costs associated with having to replace unacceptable
More informationSquare D Homeline Load Centers and Circuit Breakers. Engineered for value
Square D Homeline Load Centers and Circuit Breakers Engineered for value TM From the Square D brand you know and trust, Homeline Load Centers are engineered for value, reliability, and innovation. The
More informationThermal-Magnetic / Magnetic Only Molded Case Circuit Breakers Introduction
Thermal-Magnetic / Magnetic Only Molded ase ircuit reakers Introduction Table 8: reakdown of Typical atalog Number L 3 6 050 V 2100 reaker amily Y - mpere rame - 100 mpere rame K - 250 mpere rame L - 400
More informationTaxonomies, Classifications, and Categories Category Description PANELBOARD BRANCH BREAKERS V
4 South Street 7964-76, TX Nacogdoches Phone: 96-69-794 Fax: 96--468 Catalog Number Manufacturer Description Weight per unit Product Category Features amperage rating circuit breaker type dimensions interrupt
More informationCircuit Breakers NEED
Type BR NEED Product Description The primary function of a circuit breaker is to protect the wire from overheating (referred to as an overload) and fault currents (referred to as short circuits). Circuit
More informationTaxonomies, Classifications, and Categories Category Description PANELBOARD BRANCH BREAKERS V
4 South Street 7964-76, TX Nacogdoches Phone: 96-69-794 Fax: 96--468 Catalog Number Manufacturer Description Weight per unit Product Category Features amperage rating circuit breaker type dimensions interrupt
More informationFree-Stand Universal-Cutout Disconnects Type 12 Modular Free-Stand Disconnects and Accessories
763.422.2600 Spec-00252 L763.422.2211 Free-Stand Universal-Cutout s Type 12 Modular Free-Stand s and accessories Free-Stand Universal-Cutout s Type 12 Modular Free-Stand s and Accessories Modular Enclosure,
More information920 Remote Control (RC) Switches
920 Remote Control (RC) Switches ASCO is the global leader in power switching and controls ASCO 920 PRODUCT SPECIFICATIONS SWITCH ONLY (PANELBOARD MOUNTING) 1,2,3 () DIMENSIONS, IN.(MM) WIDTH HEIGHT DEPTH
More information4.3. Switchboards. Contents Description Pow-R-Line Drawout Molded Case Circuit Breaker Switchboards Product Selection...
.3 Product Description Drawout molded case circuit breaker switchboard Front accessible Front connected Through-the-door design drawout mechanism through 600A Insulated case UL 89 breakers up to 200A Visual
More informationMARWELL CORPORATION Manufacturer of UL Listed Meter Socket Adapters
Yellow Section Capacitor Sockets and Monitors, Temporary Service Adapters, Quick Set/Gen Set, Temporary Load Center, TSA, Transformer Load Management CAPACITOR CONTROLLER SOCKET Four - Six Jaws Wire Lugs
More informationI-Line Panelboards. Innovative design, smart bus technology, and simple installation
I-Line Panelboards Innovative design, smart bus technology, and simple installation TM Smart: designed for efficient installation Simple: Efficient Installation Process I-Line Breakers Main Lugs: Fixed-mounted
More informationThis Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount.
This Datasheet for the IC697CHS790 Rack, 9 Slots, Rear Mount. http://www.cimtecautomation.com/parts/p-14771-ic697chs790.aspx Provides the wiring diagrams and installation guidelines for this GE Series
More information7000 SERIES Power Switching Solutions. Closed Transition Transfer Switching. Delayed Transition Transfer Switching
7000 SERIES Power Switching Solutions Fig. 2: Four pole, Closed Transition Switch rated 1000 Amperes in Type 1 enclosure. Closed Transition Switching Closed Transition Switches feature main contacts that
More informationMG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD
United States MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD Product Information Features and Specifications For Use With: OEM Panels Approvals: UL
More informationDual-Feed 80A Auto Low Voltage Disconnect Panel - 80LVD02
Dual-Feed 80A Auto Low Voltage Disconnect Panel - 80LVD02 User Manual 1.1 Overview Telect s 80A, -48 Vdc Low-Voltage Disconnect (LVD) panel is a rack-mounted component with coil-operated contactors. These
More information60103 Circuit Breaker
6003 Circuit Breaker United States MINIATURE CIRCUIT BREAKER, 20/240VAC, 2A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Circuit Breaker Type: Standard
More informationMTA-156 IDC Quad Connectors
MT-156 IDC Quad Connectors MT-156 Product Facts Provides four points of contact Greater current carrying capability than Standard MT-156 Connectors Connector styles include both closed end and feedthru
More informationTaxonomies, Classifications, and Categories Category Description PANELBOARD BRANCH BREAKERS V THERMAL MAGNETIC, COMMON TRIP
3804 South Street 759647263, TX Nacogdoches Phone: 9365697941 Fax: 9365604685 Catalog Number Manufacturer Description Weight per unit Product Category Features Current Rating Interrupting Rating Poles
More informationPower Mod. Introduction and Contents. Revised 02/18/14
Introduction and Contents 02/18/14 2 METER Siemens Power Mod is a robust, flexible, and feature-rich line of modular metering designed to exceed today s market demands. Power Mod s exclusive QuickSystem
More informationSquare D QO Load Centers and Circuit Breakers. The leader for safe, reliable, and innovative solutions
Square D QO Load Centers and Circuit Breakers The leader for safe, reliable, and innovative solutions TM QO Load Centers are built on the Square D reputation for reliability, innovation, and circuit protection
More informationFree-Stand Universal-Cutout Disconnects Free-Stand Type 12 Disconnects
763.422.2600 SPEC-00250 N763.422.2211 DISCONNECT FREE-STAND UNIVERSAL-CUTOUT DISCONNECTS FREE-STAND TYPE 12 DISCONNECTS Free-Stand Universal-Cutout Disconnects Free-Stand Type 12 Disconnects TWO-DOOR WITH
More informationADDENDUM TO IB17555D INSTRUCTIONS FOR INSTALLATION, OPERATION AND MAINTENANCE OF THE CUTLER-HAMMER DIGITRIP 3000 SERIES OF PROTECTIVE RELAYS
ADDENDUM TO IB17555D INSTRUCTIONS FOR INSTALLATION, OPERATION AND MAINTENANCE OF THE CUTLER-HAMMER DIGITRIP 3000 SERIES OF PROTECTIVE RELAYS INSTRUCTION LEAFLET IB17555D_ADDENDUM Effective Date: 11/02
More informationFree-Stand Universal-Cutout Disconnects Type 12 Modular Free-Stand Disconnects and Accessories
Spec-00252 Free-Stand Universal-Cutout Disconnects Type 12 Modular Free-Stand Disconnects and Accessories Modular Disconnect Enclosure, Type 12 INDUSTRY STANDARDS UL 508A Listed; Type 12; File No. E61997
More informationASCO 920 Remote Control (RC) Switches
Maximum reliability and excellent value ASCO 920 Remote Control (RC) Switches ASCO 920 Remote Control Switch in Type Enclosure The ASCO 920 is designed as a feeder disconnect switch for load capacities
More informationTransfer Switches 5.1 Transfer Switch Equipment Product Selection Guide... Product Description... Application Description...
.1 Transfer Switch Equipment Product Selection Guide.................................... Product Description....................................... Application Description......................................2
More informationPower Switching & Controls for Business-Critical Continuity
Power Switching & Controls for usiness-critical Continuity 4-hour protection no matter when trouble strikes SCO Series 00 Power Transfer Switches for Power Outage Protection Where would you be without
More informationHeavy Duty Terminal Blocks
General Information: are available in two styles Deadfront Type (1100, 1200, 985 and 0987 series) and Barrier Type (1500, 1600 and 1700 series). Ratings and Standards: The voltage ratings of terminal blocks
More information25DTP412 12'5" Tele-Powr Pole. Features Made in USA. Material, Color, and Finish. Dimensions and Weight
25DTP412 12'5" Tele-Powr Pole Wiremold/Legrand Catalog Number 25DTP412 Manufacturer Wiremold/Legrand Description Tele Power Pole, Factory Wired; Shape Rectangular; 2 Compartment(S); 2 Outlet(S); Outlet
More informationArmorConnect Power and Control Media
Selection Guide ArmorConnect Power and Control Media Bulletins 280, 888, 889, 898 2 Bulletin 280, 888, 889, 898 Power Media Product Overview Media Description Features Trunk Cable Cordset - Cable with
More information24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD
United States 24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Approvals: IEC 60947-2 Rated
More informationSwitchboards. Product Overview
Switchboards Product Overview A switchboard distributes large electrical current used by electrical equipment and building requirements. Applications can range from a small office building to a major industrial
More informationThe City of Winnipeg Dry Type Transformers up to 600 V Primary Section Bid Opportunity No Page 1 of 2
The City of Winnipeg Dry Type Transformers up to 600 V Primary Section 26121601 Bid Opportunity No. 1196-2014 Page 1 of 2 Part 1 General 1.1 RELATED REQUIREMENTS.1 Section 26 05 01 - Common Work Results
More informationCaseta Wireless switch, 5A lighting or 3A fan, 120/277V in ivory. 600 W incandescent/halogen/140 W CFL/LED
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 PD5WSDVIV RF Switch Control Lutron Catalog Number PD5WSDVIV Manufacturer Lutron Description Caseta Wireless Switch, 5A
More information10 SEC TIME DELAY (AT 500 PERCENT RATED LOAD), DUAL ELEMENT
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 AllenWatson@elliottelectric.com Catalog Number Manufacturer Description Weight per unit Product Category Features Characteristics
More informationPLC Racks IC697CHS782/783
5 1 PLC Racks IC697CHS782/783 (IC697CHS782/783) datasheet Features Accepts 3rd Party VME modules which require 0.8 spacing. Accepts all IC697 PLC module types. Rear mount rack mounts in a 10 (254 mm) deep
More informationPower Series Transfer Switch
Power Frame Type Open and Delayed Transition Power Series Transfer Switch 2000-5000 mps Power Series 1 of 5 utomatic Transfer Switch 2000 5000, up to 600V, 50/60 Hz 3 or 4 poles NEM 1 or 3R Open with Inphase
More informationSection 20 Distribution (Underground)
PREVIOUS SEARCH NEXT Section Distribution (Underground) Table of Contents Page Underground Connectors...-2 Padmount Transformer Connectors...-3 Pedestal Connectors...-4 Pedestal Block Connector...-6 Street
More informationUS 5,634,357 D 385,7683 Bulletin: A21S4
763.422.2600 Spec-00384 H763.422.2211 Free-Stand Stainless Steel Preferred-Cutout s Stainless Steel Two-Door s Free-Stand Stainless Steel Preferred-Cutout s Stainless Steel Two-Door s Two-Door Stainless
More informationNCH-1000 (Multiple Breaker Types) Installation Instructions
20M1 12345678 NCH-1000 (Multiple Breaker Types) Installation Instructions DOC. #560502100 C 7/30/04 PRINTED IN U.S.A. Regulatory Compliance Safety This device has been tested and found to be in compliance
More informationFree-Stand Stainless Steel Preferred-Cutout Disconnects Stainless Steel Two-Door Disconnects US 5,634,357 D 385,7683 BULLETIN: A21S4
763.422.2600 SPEC-00384 J763.422.2211 DISCONNECT FREE-STAND STAINLESS STEEL PREFERRED-CUTOUT DISCONNECTS STAINLESS STEEL TWO-DOOR DISCONNECTS Free-Stand Stainless Steel Preferred-Cutout Disconnects Stainless
More informationUS 5,634,357 D 385,7683 Bulletin: A28S4
763.422.2600 Spec-00385 J763.422.2211 Free-Stand Stainless Steel Preferred-Cutout s Stainless Steel Heavy Duty s Free-Stand Stainless Steel Preferred-Cutout s Stainless Steel Heavy Duty s Stainless Steel
More informationCROWN CLIP Series Sockets
OWN LIP Series Sockets Product Facts ompact design High performance OWN BND contacts urrents to 350 mps 1 Mates with solid or laminated blades Supports true hot-plug (current interruption)2 Float-mount
More informationThe Leviton Load Center THE FUTURE MADE CURRENT
The Leviton Load Center THE FUTURE MADE CURRENT Raising the Bar Again For over 110 years, Leviton has cultivated a rich tradition of safety and innovation, developing electrical products that set the
More informationFree-Stand Stainless Steel Preferred-Cutout Disconnects Stainless Steel Heavy Duty Disconnects US 5,634,357 D 385,7683 BULLETIN: A28S4
763.422.2600 SPEC-00385 L763.422.2211 DISCONNECT FREE-STAND STAINLESS STEEL PREFERRED-CUTOUT DISCONNECTS STAINLESS STEEL HEAVY DUTY DISCONNECTS Free-Stand Stainless Steel Preferred-Cutout Disconnects Stainless
More informationCHSPMAX CHSP Max 120/240 Ac Power, 2500J
CHSP Max 120/240 Ac Power, 2500J Eaton Corp Catalog Number Manufacturer Eaton Corp Description Surge Protector, Compact; Panel Mounting; Application Ac Power, Cable, Telephone; Used On Breaker Panel, Loadcenter;
More informationApplication Techniques CENTERLINE 2100 Motor Control Centers
POWER SYSTEM CONSIDERATIONS FOR PRODUCT SELECTION Application Techniques CENTERLINE 2100 Motor Control Centers Power System Considerations for Product Selection i Power System Considerations for Product
More informationPow-R-Command 2000 System Overview
Pow-R-Command 2000 System Overview Technical Data TD01412050E Effective January 2009 Contents Advanced Web Service Technology...................... 2 Pow-R-Command 2000 General Overview................
More informationContents. Volume 5 Motor Control and Protection CA E December
Rotary Disconnects.4 Contents Description Page Product Description............................. 677 Standards and Certifications...................... 677 Product Selection..............................
More informationSingle-Phase Encapsulated
Single-Phase Encapsulated 7 50 VA to 25 kva Applications n For general loads, indoors or out, including lighting, industrial and commercial applications n Units may be banked for 3-Phase operations n For
More informationMetal-enclosed interrupter 5 kv-15 kv usa.siemens.com/siebreak
SIEREK switchgear Metal-enclosed interrupter 5 kv-15 kv usa.siemens.com/siebreak SIEREK Metal-Enclosed Interrupter Switchgear Selection and pplication Guide SIEREK medium-voltage metal-enclosed interrupter
More informationPower Series Transfer Switch
Service Entrance Rated Power Frame Type losed Transition Power Series Transfer Switch 1000-5000 mps Power Series 1 of 5 utomatic Transfer Switch, 100% Service Entrance Rated 1000 5000, up to 600V, 50/60
More informationUL 489 DIN rail branch circuit breakers
UL 9 DI rail branch circuit breakers FAZ-A circuit breakers Product Overview UL 9 DI rail branch circuit breakers FAZ-A circuit breakers PRODUCT OVERVIEW Optimum and efficient protection Optimum product
More informationMiniature Circuit Breakers and Supplementary Protectors. Contents
. Optimum and Efficient Protection for Every Application Product Overview Features Optimum product quality, tested reliability and safety stand for best protection of personnel, installations and plant.
More informationCooper B-Line RESIDENTIAL SERVICES
RESIDENTIAL SERVICES Approved Voltage Optional Voltage w/utility Approval 011 011 5 th Clip 100 Amp Socket Only, Overhead 011F 011F 5 th Clip 100 Amp Meter Socket & Circuit 1M1R 1M1R 5 th Clip Breaker
More informationFT Flexitest Family. Switches, Covers and Test Plugs
FT Flexitest Family Switches, Covers and Test Plugs FT Flexitest Switches Description The flexibility provided by the FT case design evolved into a separate family of molded base test switches for testing
More informationPower Series Transfer Switch
ypass Isolation ontactor Type losed Transition Transfer Switch 100-1200 mps 1 of 5 ypass Isolation Transfer Switch 100 1200, up to 600V, 50/60 Hz 3 or 4 poles NEM 1 or 3R losed Transition UL1008 Listed
More informationIndustrial Control. 50 to 5,000 VA. Applications. Specifications. Standards. Options and Accessories. Features, Functions, Benefits.
Industrial Control 6 50 to 5,000 VA Applications n For commercial and industrial control applications including; control panels, conveyor systems, machine tool equipment, pump systems, and commercial air
More informationClipper Power System Visor Series
Clipper Power System Visor Series Technical Data Supersedes TD.37B.21.T.E pages 1-8 dated October 2001 Description Page Applications.................................................. 2 General Description............................................
More informationIndustrial Control. 50 to 5,000 VA. Applications. Specifications. Standards. Options and Accessories. Features, Functions, Benefits.
Industrial Control 6 50 to 5,000 VA Applications n For commercial and industrial control applications including; control panels, conveyor systems, machine tool equipment, pump systems, and commercial air
More informationPower-Style QED-2, Series 2 Low Voltage Switchboards
Power-Style QED-2, Series 2 Low Voltage Switchboards Catalog 2742CT1001 (Addendum to 2742CT9501R12/09) 2010 Class 2742 CONTENTS Description............................................. Page Features...................................................
More informationZenith Series DPB Distributed Power Busway
Critical Power from GE Zenith Series DPB Distributed Power Busway Key Solutions for Datacenter Overhead Power Distribution Generation 2 GE Series DPB Gen 2 Bus System Flexible. Robust. Efficient. Specifically
More informationBulletin 194R Fused and Non-Fused Disconnects Product Selection
Product Selection 4th Pole Modules Maximum Hp Ratings Rated 1-Phase (60 Hz) -Phase (60 Hz) DC Current [A] 10V 40V 40V 480V V 1V 0V Ref. Cat. No. Non-d 0 7. 1 0 A 194R-0-NN 60 1 0 40 B 194R-60-NN UL Class
More informationInstrument Current Transformers
Catalog No. 4B Instrument Current Transformers 600 volt - 15Kv Reliability and Quick Results Reliability and quick response are the reasons you should select a Piedmont Current Transformer or have us build
More informationSECTION SWITCHBOARDS
SECTION 26 24 13 PART 1 - GENERAL 1.1 SUMMARY A. Work Included: 1. Switchboards 2. Commercial Metering Switchboards 3. Non-Utility Power Meters (Microprocessor-Based Metering Equipment) PART 2 - PRODUCTS
More informationInstallation, Operation, and Service Manual SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET
Technical Publications SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET for ARTIS Q / Q.ZEN / ONE ARTIS ZEEGO / ZEEGO.ZEN ARTIS ZEE MULTIPURPOSE SINGLE PLANE IECAX480V125A Main Disconnect Panel Bevco Engineering
More informationThe Leviton Load Center THE FUTURE MADE CURRENT
The Leviton Load Center THE FUTURE MADE CURRENT Raising the Bar Again For over 110 years, Leviton has cultivated a rich tradition of safety and innovation, developing electrical products that set the
More informationUS CATALOG. SENTRICITY Load Centers and Circuit Breakers Raising the standard in residential.
US CATALOG SENTRICITY Load Centers and Circuit Breakers Raising the standard in residential. 2 SENTRICITY LOAD CENTERS AND CIRCUIT BREAKERS SENTRICITY Residential solution Home has a power like no other.
More informationThe 400, 800, and 2300 Series, from
400, 800, 2300, 2300D Surface Nonmetallic Raceway Systems For Low Voltage and Power pplications 400, 800, 2300, 2300D Series Raceway Systems The 400, 800, and 2300 Series, from The Wiremold Company, is
More informationBulletin 194R Fused and Non-Fused Disconnects Product Selection
Product Selection 4th Pole Modules Maximum Hp Ratings Rated 1-Phase (60 Hz) -Phase (60 Hz) DC Current [A] 1V 240V 240V 480V V 12V V Ref. Non-d 0 2 7. 1 A2 194R-0-NN 60 1 0 40 B2 194R-60-NN UL Class CC
More informationFree-Stand Type 12 Disconnect Enclosures. Heavy-Duty Free-Stand Disconnect Enclosure, Type 12
Spec-00251 FPH FX (763) 422-2600 422-2211 Disconnect Free-Stand Universal-Cutout Disconnect Enclosures Heavy-Duty Free-Stand Disconnect Enclosure, Type 12 Industry Standards UL 508A Listed; Type 12; File
More informationSECTION PANELBOARDS
SECTION 16450 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for panelboards providing fault interrupting capability and overcurrent protective devices. 1.02 REFERENCE STANDARDS A.
More informationCutler-Hammer. January 2001
Cutler-Hammer January 0 Vol.,Ref. 2-2 Product Line Overview January 0 Vol., Ref. No. [068] 2 Product Line Description Cutler-Hammer Molded Case Circuit s are designed to provide circuit protection for
More informationFree-Stand Disconnects and Accessories
763.422.2600 Spec-00067 L763.422.2211 Free-Stand Preferred-Cutout s Free-Stand s and Accessories Free-Stand Preferred-Cutout s Free-Stand s and Accessories Free-Stand Enclosure, Type 1 INDUSTRY STANDARDS
More informationPLT. Breaker-based transfer switch open, closed or soft transition amps. Specification sheet
Specification sheet PLT Breaker-based transfer switch open, closed or soft transition 800 3000 amps Description PLT breaker-based transfer switches are designed for operation and switching of electrical
More informationNon-Fusible Disconnect Switches
UL 98 and IEC, Non-Fused Switches Mersen s non-fusible disconnect switches are listed to UL 98 and bear the CE mark as conformance to IEC 60947-3. They are service entrance devices that are capable of
More informationIPaCS Equipment Overview Modular Panelboard System Integrated Power Center Integrated Power Center
Table of Contents Section 0 Integrated Power and Control Solutions (IPaCS) Equipment IPaCS Equipment Overview 0- Modular Panelboard System 0-3 Integrated Power Center 0-3 Standby Power Connection Solutions
More informationPower Series Transfer Switch
Power Frame Type losed Transition Power Series Transfer Switch 1600-5000 mps Power Series 1 of 5 utomatic Transfer Switch 1600 5000, up to 600V, 50/60 Hz 3 or 4 poles NEM 1 or 3R losed Transition UL1008
More information