Tintometer -Group. Parameter, Ranges, Reagents
|
|
- Norman Cameron
- 6 years ago
- Views:
Transcription
1 Parameter, Ranges and Reagents for Spectrophotometer Spectrophotometer for water and waste water testing nm 66 Regularly updated information:
2 Parameter, Ranges, Reagents Test λ a) / nm Method Cuvette Range Display Alkalinity-m 615 Acid/Indicator 1, 2 24 mm ø mg/l CaCO 3 Alkalinity-p 551 Acid/Indicator 1, 2 24 mm ø mg/l CaCO 3 Aluminium VARIO 530 Eriochrome cyanine R 2 24 mm ø mg/l Al Aluminium 535 Eriochrome cyanine R 2 24 mm ø mg/l Al Ammonia 676 Indophenole blue 1, 2 24 mm ø mg/l N Ammonia VARIO 655 Salicylate 2 24 mm ø mg/l N Ammonia VARIO LR 655 Salicylate 2 16 mm ø mg/l N Ammonia VARIO HR 655 Salicylate 2 16 mm ø 1-50 mg/l N Arsenic (III, IV) 507 Silberdiethyldithiocarbamate 1 20 mm o mg/l As Boron 430 Azomethine 3 24 mm ø mg/l B 5 10 mm o mg/l Br 50 mm o mg/l Bromine 510 DPD 24 mm ø mg/l Bromine 510 DPD 5 24 mm ø mg/l Br Cadmium (Cd 2+ ) 525 Cadion 16 mm ø mg/l Cd 82 MSDS (Material Safety Data Sheets): 1 Deutsche Einheitsverfahren zur Wasser-, Abwasser- und Schlamm- Untersuchung 2 Standard Methods for the Examination of Water and Wastewater, 18th Edition; Photometrische Analysenverfahren, Schwedt, Wissenschaftliche Verlagsgesellschaft mbh, Stuttgart; Photometrische Analyse, Lange/Vejdelek, Verlag Chemie; Colorimetric Chemical Analytical Methods, 9th Edition, Lovibond o Rectangular cell, ø Round vial # including stirring rod, 10 cm Regularly updated information: General Catalogue March 2008
3 Reagent Form of reagent/quantity Order-No. ALKA-M-PHOTOMETER Tablet / ALKA-P-PHOTOMETER Tablet / VARIO Aluminum ECR/F20 Powder Pack / 100 VARIO Aluminum Hexamine/F20 Powder Pack / 100 VARIO Aluminum Masking Reagt. Liquid reagent / 25 ml Set ALUMINIUM No. 1 Tablette / ALUMINIUM No. 2 Tablette / Combi pack # each ALUMINIUM No.1 / No.2 each AMMONIA No. 1 Tablet / AMMONIA No. 2 Tablet / Combi pack # each AMMONIA No.1 / No.2 each VARIO Ammonia Salicylate F10 Powder Pack / VARIO Ammonia Cyanurate F10 Powder Pack / Set, each VARIO Ammonia Salicylate F5 Powder Pack / 100 VARIO Ammonia Cyanurate F5 Powder Pack / 100 VARIO Am Diluent Reagent Low Range Tube test / 50 Bottle, 100 ml Set VARIO Ammonia Salicylate F5 Powder Pack / 100 VARIO Ammonia Cyanurate F5 Powder Pack / 100 VARIO Am Diluent Reagent High Range Tube test / 50 Bottle, 100 ml Set for chemicals see manual, reagents at specialized chemistry dealer BORON No. 1 Tablet / BORON No. 2 Tablet / Combi pack # each BORON No.1 / No.2 each DPD No. 1 Tablet / DPD No. 1 HIGH CALCIUM f) Tablet / Photometry DPD 1 Buffer-Solution Liquid reagent / 15 ml DPD 1 Reagent-Solution Liquid reagent / 15 ml Spectroquant Tube test / a) Wavelength, b) Determination of free, combined and total is possible. c) User must re-calibrate the photometer with each new batch of SPADNS-reagent. Therefore the Fluoride-standard is needed d) Determination of total chromium, Cr(VI) and Cr(III) is possible e) Please order from your Merck local dealer. Spectroquant is a Merck KGaA Trademark. f) alternative reagent, used instead of DPD No.1 where turbidity in the water sample caused by high concentration of calcium and/or high conductivity g) additionally required for determination of chlorine dioxide / ozone in the presence of chlorine h) additionally required for samples with hardness values above 300 mg/l CaCO 3 * Reactor necessary for COD (150 C), TOC (120 C), total -chromium, -nitrogen, -phosphate (100 C) RT Reagent test: Includes complete set of chemicals necessary for this method TT Tube test: Includes vials and reagents 83 General Catalogue March 2008
4 Parameter, Ranges, Reagents Test λ a) / nm Method Cuvette Range Display Chlorine b) 510 DPD 1, 2 10 mm o mg/l 50 mm o mg/l 24 mm ø mg/l Cl 2 Chlorine b) 510 DPD 1, 2 24 mm ø mg/l Cl 2 Chlorine VARIO b) 510 DPD 1, 2 24 mm ø mg/l Cl 2 Chlorine HR 470 Potassium iodide 5 16 mm ø mg/l Cl 2 Chlorine Dioxide 510 DPD 1,2 50 mm o mg/l ClO 2 24 mm ø mg/l Chlorine Dioxide 510 DPD 1,2 24 mm ø mg/l ClO 2 Chloride 450 Silver nitrate/turbidity 24 mm ø mg/l Cl Chloride 455 Iron (III)-thiocyanate 4 24 mm ø 5-60 mg/l Cl Chromium d)* 542 1,5-Diphenylcarbohydrazide 1,2 50 mm o mg/l Cr 16 mm ø mg/l COD vario LR* 420 Dichromate/H 2 SO mm ø mg/l COD (ISO 15705: ) COD vario MR* 620 Dichromate/H 2 SO mm ø mg/l COD (ISO 15705: ) COD vario HR* 620 Dichromate/H 2 SO mm ø mg/l COD Copper b) 559 Biquinoline 4 50 mm o mg/l Cu 24 mm ø mg/l Copper VARIO 560 Bicinchoninate 24 mm ø mg/l Cu Cyanide 585 Pyridine-barbituric acid 1 50 mm o mg/l CN 24 mm ø mg/l DEHA 562 PPST 3 24 mm ø mg/l DEHA 84 MSDS (Material Safety Data Sheets): 1 Deutsche Einheitsverfahren zur Wasser-, Abwasser- und Schlamm- Untersuchung 2 Standard Methods for the Examination of Water and Wastewater, 18th Edition; Photometrische Analysenverfahren, Schwedt, Wissenschaftliche Verlagsgesellschaft mbh, Stuttgart; Photometrische Analyse, Lange/Vejdelek, Verlag Chemie; Colorimetric Chemical Analytical Methods, 9th Edition, Lovibond o Rectangular cell, ø Round vial # including stirring rod, 10 cm Regularly updated information: General Catalogue March 2008
5 Reagent Form of reagent/quantity Order-No. DPD No. 1 Tablet / DPD No. 1 HIGH CALCIUM f) Tablet / DPD No. 3 Tablet / Combi pack # each DPD No.1 / No.3 each DPD 1 Buffer-Solution Liquid reagent / 15 ml DPD 1 Reagent-Solution Liquid reagent / 15 ml DPD 3 Solution Liquid reagent / 15 ml VARIO Chlorine FREE-DPD/F10 Powder Pack / VARIO Chlorine TOTAL-DPD/F10 Powder Pack / CHLORINE HR (PI) Tablet / ACIDIFYING GP Tablet / Combi pack # each CHLORINE HR (KI)/ACIDIFYING GP each DPD No. 1 Tablet / DPD No. 1 HIGH CALCIUM f) Tablet / GLYCINE (additionally for ClO 2 in presence of chlorine) Tablet / 100 Combi pack # each DPD No.1 / GLYCINE each DPD 1 Buffer-Solution Liquid reagent / 15 ml DPD 1 Reagent-Solution Liquid reagent / 15 ml CHLORIDE T1 Tablet / CHLORIDE T2 Tablet / RT (Chlorid-51 / Chlorid-52) Reagent test (Liquid reagent) approx tests "PERSULF. RTG FOR CR", Powder Pack / Chromium Hexavalent Powder Pack / COD VARIO mg/l Tube test / Photometry COD VARIO mg/l Tube test / COD VARIO mg/l Tube test / COPPER No. 1 Tablet / COPPER No. 2 Tablet / Combi pack # each COPPER No.1 / No.2 each VARIO Cu 1 F10 Powder Pack / RT (Cyanid-11 / Cyanid-12 / Reagent test (Powder, Cyanid-13) Liquid reagent) / 200 Tests DEHA Solution Liquid reagent / 100 ml DEHA Tablet / a) Wavelength, b) Determination of free, combined and total is possible. c) User must re-calibrate the photometer with each new batch of SPADNS-reagent. Therefore the Fluoride-standard is needed d) Determination of total chromium, Cr(VI) and Cr(III) is possible e) Please order from your Merck local dealer. Spectroquant is a Merck KGaA Trademark. f) alternative reagent, used instead of DPD No.1 where turbidity in the water sample caused by high concentration of calcium and/or high conductivity g) additionally required for determination of chlorine dioxide / ozone in the presence of chlorine h) additionally required for samples with hardness values above 300 mg/l CaCO 3 * Reactor necessary for COD (150 C), TOC (120 C), total -chromium, -nitrogen, -phosphate (100 C) RT Reagent test: Includes complete set of chemicals necessary for this method TT Tube test: Includes vials and reagents 85 General Catalogue March 2008
6 Parameter, Ranges, Reagents Test λ a) / nm Method Cuvette Range Display DEHA 562 PPST 3 24 mm ø mg/l DEHA Fluoride 580 SPADNS 2 24 mm ø mg/l F Formaldehyde 585 H 2 SO 4 /Chromotropic acid 10 mm o 1-5 mg/l 50 mm o mg/l Formaldehyde 575 H 2 SO 4 /Chromotropic acid 16 mm ø mg/l HCHO Hardness-total 571 Metallphthalein 3 24 mm ø 2-50 mg/l CaCO 3 Hardness-total HR 571 Metallphthalein 3 24 mm ø mg/l CaCO 3 Hazen (Pt-Co units, APHA) 455 Direct reading 2 50 mm o mg Pt/l Pt-Co units Hydrazine 455 Dimethylaminobenzaldehyde 3 24 mm ø mg/l N 2 H 4 HCHO Hydrazine 455 Dimethylaminobenzaldehyde 3 24 mm ø mg/l N 2 H 4 Hydrogenperoxide 510 DPD/Catalyst 5 50 mm o mg/l H 2 O 2 24 mm ø mg/l Iodine 510 DPD 5 24 mm ø mg/l I Iron (ferrous Fe 2+, ferric Fe 3+ ) soluble Iron (ferrous Fe 2+ ) soluble Iron VARIO (ferrous Fe 2+, (ferric Fe 3+ ) soluble 562 PPST 3 10 mm o mg/l 50 mm o mg/l 24 mm ø mg/l 562 PPST 3 10 mm o mg/l 50 mm o mg/l 24 mm ø mg/l 510 1, 10- Phenantroline 1, 2 24 mm ø mg/l Fe Iron, total 590 TPTZ 24 mm ø mg/l Fe Lead (Pb 2+ ) (2-Pyridylazo)-resorcin 10 mm o mg/l Pb Lead (Pb 2+ ) (2-Pyridylazo)-resorcin 16 mm ø mg/l Pb Manganese 450 Formaldoxime 1 24 mm ø mg/l Mn Fe Fe Manganese VARIO LR 558 PAN 24 mm ø mg/l Mn Manganese VARIO HR 525 Periodate oxidation 2 24 mm ø mg/l Mn 86 MSDS (Material Safety Data Sheets): 1 Deutsche Einheitsverfahren zur Wasser-, Abwasser- und Schlamm- Untersuchung 2 Standard Methods for the Examination of Water and Wastewater, 18th Edition; Photometrische Analysenverfahren, Schwedt, Wissenschaftliche Verlagsgesellschaft mbh, Stuttgart; Photometrische Analyse, Lange/Vejdelek, Verlag Chemie; Colorimetric Chemical Analytical Methods, 9th Edition, Lovibond o Rectangular cell, ø Round vial # including stirring rod, 10 cm Regularly updated information: General Catalogue March 2008
7 Reagent Form of reagent/quantity Order-No. OXYSCAV 1 RGT Powder Pack / 200 VARIO DEHA 2 RGT Solution / 100 ml Set SPADNS-Reagent Liquid reagent / 250 ml Fluoride-Standard c) Liquid / 30 ml Spectroquant e) Reagent test / approx Tests Spectroquant e) Tube test / HARDCHECK P Tablet / HARDCHECK P Tablet / Hydrazine Test Powder Powder / 30 g Spoon VARIO Hydra 2 Liquid reagent / 100 ml HYDROGENPEROXIDE LR Tablet / Photometry DPD No. 1 Tablet / IRON LR Tablet / IRON (II) LR Tablet / VARIO Ferro F10 Powder Pack / Vario Iron TPTZ F10 Powder Pack / Spectroquant e) Reagent test / 50 Tests Spectroquant e) Tube test / MANGANESE LR 1 Tablet / MANGANESE LR 2 Tablet / Combi pack # each MANGANESE LR 1 / LR 2 each VARIO Ascorbic Acid Powder Pack / 100 VARIO Alkaline-Cyanide Liquid reagent / 50 ml VARIO PAN Indicator Liquid reagent / 50 ml VARIO Rochelle Salt Solution h) 30 ml Set VARIO Manganese Citrate Buffer F10 Powder Pack / 100 VARIO Sodiumperiodate F10 Powder Pack / 100 Set a) Wavelength, b) Determination of free, combined and total is possible. c) User must re-calibrate the photometer with each new batch of SPADNS-reagent. Therefore the Fluoride-standard is needed d) Determination of total chromium, Cr(VI) and Cr(III) is possible e) Please order from your Merck local dealer. Spectroquant is a Merck KGaA Trademark. f) alternative reagent, used instead of DPD No.1 where turbidity in the water sample caused by high concentration of calcium and/or high conductivity g) additionally required for determination of chlorine dioxide / ozone in the presence of chlorine h) additionally required for samples with hardness values above 300 mg/l CaCO 3 * Reactor necessary for COD (150 C), TOC (120 C), total -chromium, -nitrogen, -phosphate (100 C) RT Reagent test: Includes complete set of chemicals necessary for this method TT Tube test: Includes vials and reagents 87 General Catalogue March 2008
8 Parameter, Ranges, Reagents Test λ a) / nm Method Cuvette Range Display Molybdate 366 Thioglycolate 4 24 mm ø 1-30 mg/l MoO 4 Molybdate VARIO 420 Mercaptoacetic acid 24 mm ø mg/l MoO 4 Nickel 443 Dimethylglyoxime 2, 3 50 mm o mg/l Ni 24 mm ø mg/l Nitrate VARIO 410 Chromotropic acid 16 mm ø 1-30 mg/l N Nitrate 340 2,6-Dimethylphenole 2,3 16 mm ø mg/l N Nitrite 545 NED 2,3 24 mm ø mg/l N Nitrite 545 Sulfanilic acid, Naphthyl-amine 1 16 mm ø mg/l mg/l N Nitrite VARIO 507 Diazotation 24 mm ø mg/l N Nitrogen-total* 340 2,6-Dimethylphenole 2,3 16 mm ø mg/l mg/l N Nitrogen VARIO, total LR * 410 Persulphate digestion method 16 mm ø mg/l N Nitrogen VARIO, total HR * 410 Persulphate digestion method 16 mm ø mg/l N Ozone 510 DPD/Glycine 5 50 mm o mg/l O 3 24 mm ø mg/l 88 MSDS (Material Safety Data Sheets): 1 Deutsche Einheitsverfahren zur Wasser-, Abwasser- und Schlamm- Untersuchung 2 Standard Methods for the Examination of Water and Wastewater, 18th Edition; Photometrische Analysenverfahren, Schwedt, Wissenschaftliche Verlagsgesellschaft mbh, Stuttgart; Photometrische Analyse, Lange/Vejdelek, Verlag Chemie; Colorimetric Chemical Analytical Methods, 9th Edition, Lovibond o Rectangular cell, ø Round vial # including stirring rod, 10 cm Regularly updated information: General Catalogue March 2008
9 Reagent Form of reagent/quantity Order-No. MOLYBDATE HR No. 1 Tablet / MOLYBDATE HR No. 2 Tablet / Combi pack # each MOLYBDATE No.1 HR / No.2 HR each VARIO Molybdenum HR1 F10 Powder Pack / 100 VARIO Molybdenum HR2 F10 Powder Pack / 100 VARIO Molybdenum HR3 F10 Powder Pack / 100 Set RT (Nickel-51, Nickel-52) Reagent test (Powder, Liquid reagent) / 50 Tests VARIO Nitrate Chromotropic Powder Pack / 50 VARIO Nitra X Reagent tube Reaktionsküvette / 50 Bottle 100 ml Set TT (Nitrat-111) Tube test (Liquid reagent) / NITRITE LR Tablet / TT (Nitrit-101) Tube test (Powder) / Photometry VARIO Nitri 3 Powder Pack / TT (Digestion reagent, Tube test (Powder, Compensation- reagent, Nitrat-111) Liquid reagent) / VARIO TN HYDROX. LR tubes Digestion tubes / 50 VARIO PERSULFATE reagent Powder Pack / 50 VARIO TN reagent A Powder Pack / 50 VARIO TN reagent B Powder Pack / 50 VARIO TN ACID LR/HR tubes Reaktion tubes / 50 Bottle 100 ml Set VARIO TN HYDROX. HR tubes Digestion tubes / 50 VARIO PERSULFATE reagent Powder Pack / 50 VARIO TN reagent A Powder Pack / 50 VARIO TN reagent B Powder Pack / 50 VARIO TN ACID LR/HR tubes Reaktion tubes / 50 Bottle 100 ml Set DPD No. 1 Tablet / DPD No. 1 HIGH CALCIUM f) Tablet / DPD No. 3 Tablet / Combi pack # each DPD No.1 / No.3 each DPD GLYCINE g) Tablet / a) Wavelength, b) Determination of free, combined and total is possible. c) User must re-calibrate the photometer with each new batch of SPADNS-reagent. Therefore the Fluoride-standard is needed d) Determination of total chromium, Cr(VI) and Cr(III) is possible e) Please order from your Merck local dealer. Spectroquant is a Merck KGaA Trademark. f) alternative reagent, used instead of DPD No.1 where turbidity in the water sample caused by high concentration of calcium and/or high conductivity g) additionally required for determination of chlorine dioxide / ozone in the presence of chlorine h) additionally required for samples with hardness values above 300 mg/l CaCO 3 * Reactor necessary for COD (150 C), TOC (120 C), total -chromium, -nitrogen, -phosphate (100 C) RT Reagent test: Includes complete set of chemicals necessary for this method TT Tube test: Includes vials and reagents 89 General Catalogue March 2008
10 Parameter, Ranges, Reagents Test λ a) / nm Method Cuvette Range Display Phenols Aminoantipyrine 2 24 mm ø mg/l C 6 H 5 OH Phosphate-total (PMB)* 690 Phosphate-total (PMB)* 690 Phosphomolybdic acid/ 16 mm ø mg/l P Ascorbic acid mg/l PO 4 Phosphomolybdic acid/ 16 mm ø mg/l P Ascorbic acid mg/l PO 4 Phosphate LR-ortho 710 Ammonia molybdate 2, 3 24 mm ø mg/l PO 4 Phosphate HR, ortho 470 Vanadomolybdate 2 24 mm ø 1-80 mg/l PO 4 Phosphate VARIO, ortho 890 Ascorbic acid 2 24 mm ø mg/l PO 4 Phosphate VARIO, ortho 890 Ascorbic acid 2 16 mm ø mg/l PO 4 Phosphate-ortho (VM) 438 Vanadomolybdate 2 16 mm ø 3-60 mg/l PO 4 Acid digestion 16 mm ø acid hydrolyzable: Phosphate VARIO* Ascorbic acid mg/l P =^ P acid hydrolyzable mg/l PO 4 P and total Acid-/Persulphate digestion 16 mm ø total: Ascorbic acid mg/l P =^ P mg/l PO 4 P Phosphate VARIO, total* 660 Acid-/Persulphate digestion 16 mm ø mg/l P =^ P Ascorbic acid mg/l PO 4 P ph value 558 Phenol red 5 24 mm ø ph ph value 558 Phenol red 5 24 mm ø ph Potassium 730 Tetraphenylborate, Turbidity 4 24 mm ø 1-10 mg/l K Silica 820 Silicomolybdate 1,2 24 mm ø mg/l SiO 2 90 MSDS (Material Safety Data Sheets): 1 Deutsche Einheitsverfahren zur Wasser-, Abwasser- und Schlamm- Untersuchung 2 Standard Methods for the Examination of Water and Wastewater, 18th Edition; Photometrische Analysenverfahren, Schwedt, Wissenschaftliche Verlagsgesellschaft mbh, Stuttgart; Photometrische Analyse, Lange/Vejdelek, Verlag Chemie; Colorimetric Chemical Analytical Methods, 9th Edition, Lovibond o Rectangular cell, ø Round vial # including stirring rod, 10 cm Regularly updated information: General Catalogue March 2008
11 Reagent Form of reagent/quantity Order-No. PHENOLE No. 1 Tablet / PHENOLE No. 2 Tablet / TT (Phosphat-101, Tube test (Powder, Phosphat- 102, Phosphat-103) Liquid -reagent) / 24 TT (Phosphat-101, Tube test (Powder, Phosphat-102, Phosphat-103) Liquid -reagent) / PHOSPHATE No. 1 LR Tablet / PHOSPHATE No. 2 LR Tablet / Combi pack # each PHOSPHATE No.1 LR / No.2 LR each PHOSPHATE No. 1 HR Tablette / PHOSPHATE No. 2 HR Tablette / Combi pack # each PHOSPHATE No.1 HR / No.2 HR each VARIO PHOS3 F10 Powder Pack / VARIO Diluent Vial Tubes / 50 VARIO PHOS3 F10 Powder Pack / 50 Bottle 100 ml Set TT Tube test / Tubes Acid reagent / 50 VARIO Phosphate RGT, 10 ml Powder Pack / 50 Bottle 100 ml 1N NaOH Bottle / 100 ml 1.54N NaOH Bottle / 100 ml VARIO POTASSIUM PERSULFATE Powder Pack / 50 Set Tubes Acid reagent / 50 VARIO Phosphate RGT, 10 ml Powder Pack / 50 Bottle 100 ml 1.54N NaOH Bottle / 100 ml VARIO POTASSIUM PERSULFATE Powder Pack / 50 Set PHENOLRED/PHOTOMETER Tablet / PHENOLRED Solution Liquid reagent / 15 ml POTASSIUM T Tablette / SILICA No. 1 Tablet / SILICA No. 2 Tablet / Combi pack # each SILICA No.1 / No.2 each SILICA PR (in presence of phosphate) Tablet / Photometry a) Wavelength, b) Determination of free, combined and total is possible. c) User must re-calibrate the photometer with each new batch of SPADNS-reagent. Therefore the Fluoride-standard is needed d) Determination of total chromium, Cr(VI) and Cr(III) is possible e) Please order from your Merck local dealer. Spectroquant is a Merck KGaA Trademark. f) alternative reagent, used instead of DPD No.1 where turbidity in the water sample caused by high concentration of calcium and/or high conductivity g) additionally required for determination of chlorine dioxide / ozone in the presence of chlorine h) additionally required for samples with hardness values above 300 mg/l CaCO 3 * Reactor necessary for COD (150 C), TOC (120 C), total -chromium, -nitrogen, -phosphate (100 C) RT Reagent test: Includes complete set of chemicals necessary for this method TT Tube test: Includes vials and reagents 91 General Catalogue March 2008
12 Parameter, Ranges, Reagents Test λ a) / nm Method Cuvette Range Display Silica LR VARIO 815 Heteropoly blue 2 24 mm ø mg/l SiO 2 Silicia HR VARIO 452 Silicomolybdate 24 mm ø mg/l SiO 2 Spectral Absorption-coefficient Direct Reading 1 50 mm o 0-50 m ISO 7887:1994 Sulphate VARIO 450 Barium sulphate, Turbidity 2 24 mm ø mg/l SO 4 Sulphide 668 DPD/Catalyst 3,4 24 mm ø mg/l S Sulphite LR 405 DTNB 10 mm o mg/l 24 mm ø mg/l SO 3 Surfactants (anionic) 653 Methylene blue 1 16 mm ø mg/l MBAS TOC* 596 H 2 SO 4 / Indicator 16 mm ø mg/l TOC Turbidity 860 Attenuated Radiation Method 50 mm o NTU Urea 610 Urease / Indophenole 24 mm ø mg/l Urea Zinc 616 Zincon 3 24 mm ø mg/l Zn 92 MSDS (Material Safety Data Sheets): 1 Deutsche Einheitsverfahren zur Wasser-, Abwasser- und Schlamm- Untersuchung 2 Standard Methods for the Examination of Water and Wastewater, 18th Edition; Photometrische Analysenverfahren, Schwedt, Wissenschaftliche Verlagsgesellschaft mbh, Stuttgart; Photometrische Analyse, Lange/Vejdelek, Verlag Chemie; Colorimetric Chemical Analytical Methods, 9th Edition, Lovibond o Rectangular cell, ø Round vial # including stirring rod, 10 cm Regularly updated information: General Catalogue March 2008
13 Reagent Form of reagent/quantity Order-No. VARIO Amino Acid F10 Powder Pack / 100 VARIO Citric Acid F10 Powder Pack / 100 VARIO Molybdate 3 Reagent solution Liquid reagent / 50 ml Set VARIO Silica HR Molybdate F10 Powder Pack / 100 VARIO Silica HR Acid Rgt F10 Powder Pack / 100 VARIO Silica HR Citric Acid F10 Powder Pack / 100 Set VARIO Sulpha 4 Powder Pack / SULFIDE No. 1 Tablet / SULFIDE No. 2 Tablet / SULFITE LR Tablet / Photometry Spectroquant e) Tube test / Spectroquant e) Tube test / Aluminium screwcaps (6 pc.) UREA Reagent 1 Liquid reagent / 15 ml UREA Reagent 2 Liquid reagent / 10 ml AMMONIA No. 1 Tablet / AMMONIA No. 2 Tablet / Combi pack # each AMMONIA No.1 / No.2 each COPPER/ZINC LR Tablet / EDTA (in case of zinc in presence of chlorine) Tablet / DECHLOR Tablet / a) Wavelength, b) Determination of free, combined and total is possible. c) User must re-calibrate the photometer with each new batch of SPADNS-reagent. Therefore the Fluoride-standard is needed d) Determination of total chromium, Cr(VI) and Cr(III) is possible e) Please order from your Merck local dealer. Spectroquant is a Merck KGaA Trademark. f) alternative reagent, used instead of DPD No.1 where turbidity in the water sample caused by high concentration of calcium and/or high conductivity g) additionally required for determination of chlorine dioxide / ozone in the presence of chlorine h) additionally required for samples with hardness values above 300 mg/l CaCO 3 * Reactor necessary for COD (150 C), TOC (120 C), total -chromium, -nitrogen, -phosphate (100 C) RT Reagent test: Includes complete set of chemicals necessary for this method TT Tube test: Includes vials and reagents 93 General Catalogue March 2008
Parameter, Ranges and Reagents
Parameter, Ranges and Reagents MultiDirect Photometer Tintometer -Group Parameter, Ranges, Reagents Test λ a) / nm Method Range Display Alkalinity-m (total) 610 Acid/Indicator 1, 2 5-200 mg/l CaCO 3 Alkalinity-p
More informationAvailable tests for the photometer AL 450 (MultiDirect) most recent amendment
20 Acid demand ph 4.3 610 Acid / Indicator 1, 2 0.1-4 mmol/l ALKA-M-PHOTOMETER 4513210BT 30 Alkalinity-m (total) 610 Acid / Indicator 1, 2 5-200 mg/l CaCO 3 ALKA-M-PHOTOMETER 4513210BT 31 Alkalinity-m
More informationApplications of Reagents
Applications of Reagents Parameter Reagent Application Acid capacity Ks4.3 ALKA-M-PHOTOMETER Acid concentration Alkalinity-m Alkalinity-p ACID CONCENTRATION ALKA-M-PHOTOMETER ALKA-P-PHOTOMETER Aluminium
More informationReagents also compatible in Hach
Reagents also compatible in Hach VARIO Powder Packs (PP) and Reagents Test Range Reagent Liquid Reagent Tube Tests Powder Pack VARIO Aluminium Reagent, Set F20 Aluminium 0 0.22 mg/l Al VARIO Aluminium
More informationReagents also compatible in
Reagents also compatible in VARIO Powder Packs (PP) and Reagents for Photometry Test Range Reagent Liquid Reagent Tube Tests Powder Pack VARIO Aluminium Reagent, Set F20 Aluminium 0 0.22 mg/l Al VARIO
More informationMD 600 Multi-Parameter Colorimeter
MD 600 Multi-Parameter Colorimeter Specifications Display Interfaces Optics Wavelength Accuracy Backlit graphic-display Infrared interface for test data transfer 1, RJ45 socket for Internet updates 2 LEDs,
More informationInstruments and Reagents for Water Analysis. General Catalog. Volume 104
General Catalog Instruments and Reagents for Water Analysis sales@novatech-usa.com www.novatech-usa.com Tel: (866) 433-6682 Fax: (866) 433-6684 Tel: (281) 359-8538 Fax: (281) 359-0084 www.lovibond.com
More informationAccurate and reliable water testing. 1 JENCOLOR Sensor - ALL Parameters (visible wavelength range) Fast Bluetooth - Connection.
Accurate and reliable water testing 1 JENCOLOR Sensor - ALL Parameters (visible wavelength range) Fast Bluetooth - Connection Powerful Software Sensor/Optics by Photometer meets Future Photometers for
More informationOPERATOR S MANUAL V-2000 Photometer
OPERATOR S MANUAL V-2000 Photometer CHEMetrics, Inc. 4295 Catlett Road Calverton, Virginia 20138 Toll Free 1-800-356-3072 Phone: 540-788-9026 Fax: 540-788-4856 Web: www.chemetrics.com Sept. 09, Rev. 13
More informationOPERATOR S MANUAL V-2000 Photometer (with 45+ factory calibrations)
OPERATOR S MANUAL V-2000 Photometer (with 45+ factory calibrations) CHEMetrics, Inc. 4295 Catlett Road Midland, Virginia 22728 Toll Free 1-800-356-3072 Phone: 540-788-9026 Fax: 540-788-4856 Web: www.chemetrics.com
More informationWELCOME TO YOUR NEW exact idip. Let us show you around. CONTENTS WELCOME
QUiCK start guide 2 CONTENTS Welcome...2 idip Overview...3 Let s Get Started Install Batteries...4 Download App...4 Home Screen...5 Test Result Screen...5 Select, Fill, Dip, Read Select Customer...6 Turn
More informationANALYTICAL REPORT. Town of Stettler Box 280 Stettler, AB T0C 2L0. Grant McQuay. Client: Attention:
ANALYTICAL REPORT Client: Town of Stettler Box 280 Stettler, AB T0C 2L0 KaizenLAB JOB #: DATE RECEIVED: 07-Jul-2016 179357 Attention: Grant McQuay DATE REPORTED: PROJECT ID: 13-Jul-2016 LOCATION: Routine
More informationCHLORINE DIOXIDE (0 to 5.00 mg/l) Method 10126
CHLORINE DIOXIDE (0 to 5.00 mg/l) Method 10126 DPD Method* Scope and Application: for measuring chlorine dioxide in clean water For water 530 nm 1. Enter the stored program for chlorine dioxide (ClO 2
More informationWater Testing. Commercial Photometers. Commercial Tablet Reagents. Photometer Test Kit Parts & Accessories. Pocket Testers.
Water Testing Commercial Photometers Commercial Tablet Reagents Photometer Test Kit Parts & Accessories Pocket Testers Test Strips Domestic Testing Water Testing Lovibond MD 100 The MD 100 is the latest
More informationexact Strip DPD-1 Comparison on EPA-Compliant Meters Additional Parameters Available for exact EZ Ordering Replacement Strips & Components
exact Strip DPD- Comparison on EPA-Compliant Meters The data compares performance of exact Strip DPD- on two () EPA-Compliant meters (the exact EZ Advanced Photometric System and the Hach DR890, Program
More informationNitrite photometer. mono. Operating Instructions
Nitrite photometer mono Operating Instructions Contents 1. Important Safety Information 1.1 Notes and symbols used in these instructions 1.2 Intended use 1.3 Staff qualifications 1.4 Warning notices in
More informationFrench Creek Software, Inc. Quick Start Guide
French Creek Software, Inc Quick Start Guide Inside This Guide Section 1: Setup - Overview & Install 4 Software Overview System Requirements 5 Installation Section 2: Getting Around - Get to Modeling 7
More informationAdvanced Portable Model AQ4000
Advanced Portable Model AQ4000 INSTRUCTION MANUAL A Thermo Electron business AQUAfast, Auto-ID, Cahn, EZFlash, Ionalyzer, ionplus, KNIpHE, ORION, perphect, PerpHecT, PerpHecTion, phisa, phix, phuture,
More informationSMART PHOTOMETER SYSTEM. with QUICK START GUIDE
SMART PHOTOMETER SYSTEM with QUICK START GUIDE 2 CONTENTS Welcome........................................... 3-4 Warranty (2 years).................................... 4 For Best Accuracy.....................................
More information6.3.1 Reset Service Calibration Zero calibration Turbidity calibration Connectivity...
Content i Content 1 Introduction... 6 1.1 CE mark... 6 1.2 Nameplate... 6 1.3 Explanation of symbols... 6 1.4 Technical description... 7 1.5 Technical details... 7 2 Safety precautions... 8 2.1 Input supply...
More informationSMART PHOTOMETER SYSTEM with QUICK START GUIDE
SMART PHOTOMETER SYSTEM with QUICK START GUIDE 2 CONTENTS Welcome........................................... 3-4 Warranty (2 years).................................... 4 For Best Accuracy.....................................
More informationPalintest. Pooltest 25 Bluetooth. Operation Manual. Palintest. ZI INST 7025B En
Palintest Pooltest 25 Bluetooth Operation Manual ZI INST 7025B En Palintest Palintest Who We Are Palintest aim to be the best global provider of water and environmental analysis equipment that enable critical
More informationSpectrophotometers for the lab
Photometers HACH LANGE photometers consistently break innovation barriers to deliver top performance for both routine laboratory tasks and demanding photometry applications. Our photometers are engineered
More informationActivity concentration for exempt material (Bq/g)
173.436 Exempt material activity concentrations and exempt consignment activity limits for radionuclides. The Table of Exempt material activity concentrations and exempt consignment activity limits for
More informationWHO WATER QUALITY CONTROL Code Commodity Supplier /
WHO WATER QUALITY CONTROL 02-11-00001 Incubator, Stuart high performance (Cat. No. IN 100-45) Patterson Scientific pcs 7 02-11-00002 Incubator Series BE (Cat. No. IN 460-22) Patterson Scientific pcs 3
More informationUser guide. The utterly reliable analytical laboratory
User guide The utterly reliable analytical laboratory How to contact us For all enquiries (quotes for analysis, technical advice, container requirements or collection of samples), email us at ask@envlab.co.uk
More informationTable of Contents. Chapter 1 Introduction General Information... 1 Meter Packing List... 2
Table of Contents Chapter 1 Introduction General Information.................................................. 1 Meter Packing List................................................... 2 Chapter 2 Meter
More informationTaylor Technologies, Inc. 800-TEST KIT ( ) TTi. Colorimeter Series User s Manual
Taylor Technologies, Inc. 800-TEST KIT (837-8548) www.taylortechnologies.com TTi Colorimeter Series User s Manual TTi Colorimeter Series User s Manual TTi Colorimeter Series User s Manual First Edition
More informationSMART Spectro. L Mott OPERATOR S MANUAL. v2.2 Printed MN. Spectrophotometer
SMART Spectro Spectrophotometer OPERATOR S MANUAL L Mott v2.2 Printed-04.08 2000-MN TABLE OF CONTENTS GENERAL INFORMATION Packaging & Delivery 5 General Precautions 5 Safety Precautions 5 Limits of Liability
More informationASTORIA PACIFIC ASTORIA PACIFIC ASTORIA ANALYZERS. Automated Wet-Chemistry Analyzers and Diagnostic Reagents
ASTORIA PACIFIC ASTORIA PACIFIC Automated Wet-Chemistry Analyzers and Diagnostic Reagents ASTORIA ANALYZERS Our Company Astoria-Pacific is committed to providing superior solutions to meet the specific
More informationGeotech Services, X-18, MIDC, Hingna, Nagpur, Maharashtra. Discipline Chemical Testing Issue Date
Last Amended on 11.01.2014 Page 1 of 6 I. WATER 1. WATER (For Construction Purpose Only) ph Value IS 3025 (Part 11) : 1983 (Clause 2.0) Suspended Matter IS 3025 (Part 17) : 1984 Organic matter IS 3025
More informationa ae (Chemi m cal bon o d)
a ae (Chemical bond) å å å a a ooo i o i a ao e e e a ao a a å å å å o æ e и å o e u и 2 ae o æ e и å o e u ( a å o u å o ooo ) æ a ao a a ao e e a a ooo i æ e и a å o e u æ a a o e æ a å a æ o o å å å
More informationInstruction Manual C 102. Multiparameter Turbidity & Ion Specific Meter. This Instrument is in Compliance with the CE Directives.
Instruction Manual C 102 Multiparameter Turbidity & Ion Specific Meter This Instrument is in Compliance with the CE Directives www.hannainst.com Dear Customer, Thank you for choosing a Hanna Product. Please
More informationApplication of JENCOLOR hyperspectral sensor testing liquits
Application of JENCOLOR hyperspectral sensor testing liquits Dr. Fred Grunert 17.10.2014 Lichtenwalde SENSORSYSTEME 2014 Agenda 1 2 MAZeT Working principle of hyperspectral sensor 3 Working principle of
More informationPalintest. Pooltest 9 Bluetooth. Operation Manual. Palintest ZI INST 7009
Palintest Pooltest 9 Bluetooth Operation Manual ZI INST 7009 Palintest Palintest Who We Are Palintest aim to be the best global provider of water and environmental analysis equipment that enable critical
More informationThe Ultimate Automated Water Analyzer. Ready to go anywhere! Pool Operators Service Technicians Retail Professionals
WaterLink Sp ntouch The Ultimate Automated Water Analyzer Ready to go anywhere! Pool Operators Service Technicians Retail Professionals WaterLink Sp ntouch Every now and then a technology emerges that
More informationTitrIC Vario pro. Multi parameter analysis by titration and ion chromatography combined
TitrIC Vario pro Multi parameter analysis by titration and ion chromatography combined TitrIC Vario pro the dream team for comprehensive ion analysis 02 Comprehensive analysis of ionic components in liquid
More informationConductive Ex leakage detectors of the Leckstar range
Conductive Ex leakage detectors of the Leckstar range with electrode and relay Jola Spezialschalter GmbH & Co. KG Klostergartenstr. 11 67466 Lambrecht (Germany) Tel. +49 6325 188-01 Fax +49 6325 6396 www.jola-info.de
More informationFeed Check Sample No Chicken Starter/Grower, Medicated Association of American Feed Control Officials
Feed Check Sample No. - 200926 Chicken Starter/Grower, Medicated Association of American Feed Control Officials - Pass 1 Results for 207 Labs - - Pass 2 Results for 206 Labs - No. Average No. Average AOAC
More informationThe Ultimate Automated Water Analyzer. Ready to go anywhere! Pool Operators Service Technicians Retail Professionals
WaterLink Sp ntouch The Ultimate Automated Water Analyzer Ready to go anywhere! Pool Operators Service Technicians Retail Professionals WaterLink Sp ntouch Every now and then a technology emerges that
More informationDiving into a new dimension: Quality meets efficiency
Diving into a new dimension: Quality meets efficiency DR 6000 UV-VIS spectrophotometer Combining quality and cost-effectiveness The new DR 6000 UV-VIS spectrophotometer delivers top performance for both
More informationFeed Check Sample No Preconditioning/Receiving Chow, Med Association of American Feed Control Officials
Feed Check Sample No. - 200929 Preconditioning/Receiving Chow, Med Association of American Feed Control Officials - Pass 1 Results for 212 Labs - - Pass 2 Results for 211 Labs - No. Average No. Average
More informationFeed Check Sample No Foundation Cattle Mineral, Medicated Association of American Feed Control Officials
Feed Check Sample No. - 200927 Foundation Cattle Mineral, Medicated Association of American Feed Control Officials - Pass 1 Results for 170 Labs - - Pass 2 Results for 168 Labs - No. Average No. Average
More informationWater Quality Measurement Products
2017 HF scientific Catalog Water Quality Measurement Products Full Line Catalog Table of Contents Terms & Conditions Turbidity OnLine Turbidimeter MTOL Plus... 1 MicroTOL... 1 Accessories & Options...
More informationBCA protein assay kit for low concentrations. For measuring total protein concentration of pure proteins, extracts or lysates.
ab207002 BCA protein assay kit for low concentrations Instructions for use: For measuring total protein concentration of pure proteins, extracts or lysates. This product is for research use only and is
More informationTEST REPORT MATERIAL SUBMITTED IMPORTER COMPANY MODEL NO SUPPLIER REFERENCE BUYER : : : :
TEST REPORT AB-0505-T MATERIAL SUBMITTED IMPORTER COMPANY MODEL NO SUPPLIER REFERENCE BUYER LAB LOCATIONTURKEY LAB NO. (7217)265-0049 SERVICE TYPE Regular DATE IN September 22 th, 2017 DATE OUT October
More informationReplacement Information Item Description List Price Comments Item Part # Replacement Decsription METERS- PORTABLE ph
Replacement Information Item Description Comments Item Part # Replacement Decsription METERS- PORTABLE ph 475660 CHEK-MITE ph-10 ph TESTER Discontinued Replaced w/ EcoSense Model EcoSense ph10 606pH10
More informationTreatment Instructions for WEEE By: Ageus Solutions
Motion Computing Page 1 of 15 Motion Computing LE100 June 18, 200 Brand Owner Identification Motion Computing, Inc. 8601 RR 222, Building II Austin, Texas 830 http://www.motioncomputing.com Identification
More informationFeed Check Sample No Meat and Bone Meal (Pork) Association of American Feed Control Officials
Feed Check Sample No. - 200997 Meat and Bone Meal (Pork) Association of American Feed Control Officials - Pass 1 Results for 193 Labs - - Pass 2 Results for 192 Labs - No. Average No. Average AOAC Method
More informationELECTRONIC CATALOGUE CUSTOMER S AMENDMENTS ISSUE 1 January 2011 Page 1 of 9 pages
A J COPE & SON LTD The Oval London E2 9DU Telephone: +44 (0) 20 7729 2405 Facsimile: +44 (0) 20 7729 2657 ELECTRONIC CATALOGUE CUSTOMER S AMENDMENTS ISSUE 1 January 2011 Page 1 of 9 pages Internet: www.ajcope.co.uk
More informationInorganic Chemicals (IOCs)
Burlington, WA Corporate Laboratory (a) 1620 S Walnut St - Burlington, WA 98233-800.755.9295 360.757.1400 Bellingham, WA Microbiology (b) 805 Orchard Dr Ste 4 - Bellingham, WA 98225-360.715.1212 Portland,
More informationSpring 2016 Summary Report Residential Drinking Water Well Sampling LRI Landfill
Spring 2016 Summary Report Residential Drinking Water Well Sampling LRI Landfill Contents 1. Summary 2. Table 1 Spring 2016 Water Quality Results 3. Table 2 Spring 2016 Water Quality VOC Results 4. Table
More informationSpring 2017 Summary Report Residential Drinking Water Well Sampling LRI Landfill
Spring 2017 Summary Report Residential Drinking Water Well Sampling LRI Landfill Contents 1. Summary 2. Table 1 Spring 2017 Water Quality Results 3. Table 2 Spring 2017 Water Quality VOC Results 4. Table
More informationTEST REPORT : SCENTCO LIMITED. : China : USA, EU, ASIA. : 16-May EN71 Part 3:2013 Migration of Certain Elements Pass
TEST REPORT Page : 1 of 10 APPLICANT ADDRESS : SCENTCO LIMITED : RM 401, 4/F, SUNG KEE IND. BLDH., 18 KWAI TING ROAD, KWAI CHUNG, N.T., HONG KONG SAMPLE DESCRIPTION VENDOR COUNTRY OF ORIGIN COUNTRY OF
More informationLIGHT SOURCE Quartz-iodine lamp 12V-20W.
SPECIFICATIONS THROUGHPUT Up to 180 tests per hour; Up to 300 tests per hour with ISE unit. REAGENT SYSTEM Rotor with 24 positions for 25 ml bottles and 8 positions for 5 ml bottles. All positions can
More informationSupporting Information. Highly Selective and Reversible Chemosensor for Pd 2+ Detected by Fluorescence, Colorimetry and Test Paper.
Supporting Information Highly Selective and Reversible Chemosensor for Pd 2+ Detected by Fluorescence, Colorimetry and Test Paper Mian Wang, Xiaomei Liu, Huizhe Lu, Hongmei Wang* and Zhaohai Qin* Department
More informationWater Quality Measurement Products
Water Quality Measurement Products 2013 Web Site: www.hfscientific.com Web Site: Process Control Services Pty Ltd A.B.N. 22 054 111 018 Phone: Brisbane - (07) 3299 7881, Melbourne - (03) 9859 0157, Sydney
More informationProduct Name: P&S. Monitor8 Plug&Sense! Waspmotes and Sensors. Reference:
Monitor8 Plug&Sense! Waspmotes and Product Name: IoT Vertical Kits Smart Cities IoT Vertical Kit Smart Parking IoT Vertical Kit Smart Agriculture IoT Vertical Kit Smart Environment IoT Vertical Kit Smart
More informationSOLUTIONS RECERTIFICATION CALIBRATION AND UV/VIS REFERENCE MATERIALS. Photometric and Wavelength Accuracy Reference Material Set
UV/VIS REFERENCE MATERIALS CALIBRATION AND RECERTIFICATION SOLUTIONS Photometric and Wavelength Accuracy Reference Material Set Photometric and Wavelength Accuracy Reference Material Set A set of reference
More information2017 Water Analysis Report
Primary Inorganics Antimony 0.001 0.006 ND ND ND Arsenic 0.002 0.01 ND ND ND Asbestos (MFL) 0.2 7 ND ND ND Barium 0.1 2 ND ND ND Beryllium 0.001 0.004 ND ND ND Cadmium 0.001 0.005 ND ND ND Chromium 0.01
More informationTreatment Instructions for WEEE
Motion Computing Page 1 of 20 TI C TABLET PC. Brand Owner Identification Motion Computing, Inc. 8601 RR 222, Building II Austin, Texas 78730 http://www.motioncomputing.com Product Identification Product
More informationab BCA protein assay kit reducing agent compatible (test tube)
ab207004 BCA protein assay kit reducing agent compatible (test tube) Instructions for use: For measuring total protein concentration of pure proteins, extracts or lysates in the presence of reducing agents.
More informationProtein Quantification Kit (BCA Assay)
Protein Quantification Kit (BCA Assay) Booklet Item NO. KTD3001 Product Name Protein Quantification Kit (BCA Assay) ATTENTION For laboratory research use only. Not for clinical or diagnostic use Version
More informationInstruction Manual. ph 700 ph/mv/ C/ F Bench Meter. Ion 700 ph/mv/ion/ C/ F Bench Meter. Technology Made Easy...
Instruction Manual ph 700 ph/mv/ C/ F Bench Meter Ion 700 ph/mv/ion/ C/ F Bench Meter Technology Made Easy... Part of Thermo Fisher Scientific 68X541701 Rev.4 Apr 2013 TABLE OF CONTENTS 1. INTRODUCTION...
More informationMEMORANDUM SUBJECT: LICENSING AND REGISTRATION OF FERTILIZERS FOR 2007
MEMORANDUM TO: FROM: DISTRIBUTORS AND POTENTIAL DISTRIBUTORS OF FERTILIZER IN KENTUCKY D. L. TERRY, COORDINATOR FERTILIZER REGULATORY PROGRAM DATE: March 14, 2007 SUBJECT: LICENSING AND REGISTRATION OF
More informationWaspmote Plug & Sense. Quick Overview
Waspmote Plug & Sense Quick Overview Index Document version: v7.5-11/2017 Libelium Comunicaciones Distribuidas S.L. INDEX 1. Waspmote Plug & Sense! v15...4 2. Waspmote Plug & Sense!...5 2.1. Features...
More informationGetting Data. This guide will take you step by step, button click by button click, through using S1PXRF and your Tracer
Getting Data You can easily obtain spectra from your Tracer using the S1PXRF software. This enables you to see your spectrum as it is gathered, and do both qualitative and quantitative analysis. This guide
More informationMulti-Parameter Handheld Photometer PPM 150 OPERATING INSTRUCTIONS
Multi-Parameter Handheld Photometer PPM 150 OPERATING INSTRUCTIONS 1 Contents Introduction 5 Technical Data 6 Scope of delivery 7 Things to know 9 Operating the photometer Keyboard 11 Energy-saving function
More informationISO INTERNATIONAL STANDARD. Water quality Digestion for the determination of selected elements in water Part 2: Nitric acid digestion
INTERNATIONAL STANDARD ISO 15587-2 First edition 2002-03-01 Water quality Digestion for the determination of selected elements in water Part 2: Nitric acid digestion Qualité de l'eau Digestion pour la
More informationHI TOTAL ACIDITY MINITITRATOR & ph METER for Water Analysis
Instruction Manual HI 84530 TOTAL ACIDITY MINITITRATOR & ph METER for Water Analysis www.hannainst.com 1 Dear Customer, Thank you for choosing a Hanna Instruments product. Please read this instruction
More informationNutrient Profile Dalex Livestock Solutions All values except moisture are reported on a dry matter basis.
INGREDIENT NUTRIENT ANALYSIS 1 Dry Matter % 95.000 2 Protein % 3 RUP (%CP). - 4 RDP (%CP). - 100.000 5 SOL (%CP). - 211 NPN %SOL (%CP) 6.1-6 NPN % 7 ME CNCPS Mcal/lb 79 NEL Level 1 Mcal/lb 8 NEL CNCPS
More informationPalintest PHOTOMETER 7500 INSTRUMENTS. INST.7500.C Version 3-01/09
Palintest INSTRUMENTS PHOTOMETER 7500 INST.7500.C Version 3-01/09 Your Palintest direct-reading photometer is designed to give long and trouble-free operation. To ensure you get the best out of this photometer,
More informationELECTRONIC CATALOGUE CUSTOMER S AMENDMENTS ISSUE 04 JULY 2010 Page 1 of 4 pages
A J COPE & SON LTD The Oval London E2 9DU Telephone: +44 (0) 20 7729 2405 Facsimile: +44 (0) 20 7729 2657 ELECTRONIC CATALOGUE CUSTOMER S AMENDMENTS ISSUE 04 JULY 2010 Page 1 of 4 pages Internet: www.ajcope.co.uk
More informationLuminous Flux. Emergency operation
50,000 h product life Zone 1 and 21 Frequency 0 50/60Hz 850 C Rated voltage 220 240V +40 C -20 C KRATEX NS HE 600 2000-840 ET GLASS General characteristics LED Luminaire manufactured with high quality
More informationTutorial EN
Tutorial 8.102.8001EN Metrohm AG CH-9101 Herisau Switzerland Phone +41 71 353 85 85 Fax +41 71 353 89 01 info@metrohm.com www.metrohm.com Tutorial 8.102.8001EN 07.2009 ek Teachware Metrohm AG CH-9101
More informationDuriron Corrosion Resistant Piping
Foundry Operations Corrosion Resistant Piping Chemical Compatibility Chart FCD FDATB0016 (Bulletin PF-16b) Corrosion Resistant Piping For nearly 90 years pipe and fittings have provided a durable and reliable
More informationWater Analysis. NANOCOLOR heating blocks MACHEREY-NAGEL. Heating blocks of the future
MACHEREY-NAGEL NANOCOLOR heating blocks Water Analysis Heating blocks of the future n Fast and reliable sample digestions n Touch screen with intuitive user guidance n Lockable protective lids for maximum
More information875 ProcessLab. At-line Analyzer for Process Analysis
875 ProcessLab At-line Analyzer for Process Analysis ProcessLab the innovative solution for routine analysis in production 02 ProcessLab is a robust analytical system for routine analysis in the plant.
More informationApplication for registration of a compost, potting soil product, mulch material, substrate, of degradable pots or technical materials
Will be filled automatically: Please fill in this form electronically and send it directly to by using the Send- Button at the end of the form. Sending the forms via letter post is not necessary. Please
More informationANALYTICAL REPORT. Job Number: SDG Number: Valley Central SD - Maybrook Job Description: Orange-Ulster BOCES
ANALYTICAL REPORT SDG Number: Valley Central SD - Maybrook Job Description: For: Attention: Jack DeGraw Meredith W Ruthven Customer Service Manager mruthven@envirotestlaboratories.com NYSDOH ELAP does
More informationHOLIDAY HOME WORK CLASS X ENGLISH
HOLIDAY HOME WORK CLASS X ENGLISH Q1. Prepare a project report on: - Life history and achievements of Shakespeare. (10-12 pages) Q2. Write articles on the following topics: - (i) Conservation of environment
More informationCem Kırt.Büro Malz.ve Gıda Tic. Ltd. Şti.
TEST REPORT Page 1 of 16 REPORT NUMBER : APPLICANT NAME ADDRESS SAMPLE DESCRIPTION : BUYER : TURT180108559 Cem Kırt.Büro Malz.ve Gıda Tic. Ltd. Şti. İstoç, 18 Ada Gönül Plaza K:4 Bağcılar - İstanbul FAX
More informationFALL 2017 SEMI-ANNUAL WATER QUALITY MONITORING REPORT FOR THE HALIFAX MUNICIPAL LANDFILL
FALL 207 SEMI-ANNUAL WATER QUALITY MONITORING REPORT FOR THE HALIFAX MUNICIPAL LAFILL December 2, 207 VTDEC Project NS95-065 Prepared for: Town of Halifax P.O. Box 45 Halifax, Vermont 05358 Prepared by:
More informationHI TOTAL ACIDITY MINITITRATOR & ph METER for Water Analysis
Instruction Manual HI 84430 TOTAL ACIDITY MINITITRATOR & ph METER for Water Analysis www.hannainst.com 1 Dear Customer, Thank you for choosing a Hanna product. This manual will provide you with the necessary
More informationPhotometer-System MD100
Lovibond Water ing Tintometer Group Photometer-System MD100 Phosphat Phosphate Phosphate Fosfato Fosfato Tablet Powder GB Instruction Manual Page 18 31 www.lovibond.com CE-Konformitätserklärung / Declaration
More informationTRACEABILITY and UNCERTAINTY 7
cobas c 01 / c 02 / c 11 / c 701 / c 702 - C.f.a.s. Cat. No. 10 79 0 190 ACP2 Acid phosphatase total 1-naphthyl phosphate Gen. 2 ACP2 Acid phosphatase, non-prostatic 1-naphthyl phosphate (Inhib.:tartrate)
More informationPARTICIPANT STATISTICS Chemistry Q Chemistry i-stat. Specimen 1 Specimen 2 Specimen 3 Specimen 4 Specimen 5
PARTICIPANT STATISTICS Chemistry Q 20 Chemistry i-stat Name Bicarbonate (Total CO2) - istat 25.0-37.0 P 30.9..0-9.0 C 5.4 0.7 8.0-26.0 P 22. 0.4 24.0-35.0 P 29.4.0 39.0-58.0 P 48.3.7 9 24.0-36.0 P 30..6.0-9.0
More informationELECTROCHEMISTRY. BOECO ELECTRODES The electrodes are not included with the ph meters and have to be ordered separately:
BOECO PORTABLE PH/ORP/TEMP METER MODEL PT-380 A Simultaneous displays ph or mv and temperature. A Convenient calibration with automatic buffer recognition of European and US buffer sets. Calibration data
More informationNutrient Profile CNCPS All values except moisture are reported on a dry matter basis.
Moisture % 13.000 0.000 DM % 87.000 100.000 CF % 0.000 0.000 NDF % 15.020 17.270 ADF % 4.240 4.870 ADL % 1.610 1.850 SC % 0.000 0.000 Forage NDF % 0.000 0.000 pendf % 0.935 1.070 NFC % 15.208 17.408 Total
More informationNutrient Profile CNCPS
Moisture % 3.000 0.000 DM % 97.000 100.000 CF % 0.000 0.000 NDF % 0.000 0.000 ADF % 0.000 0.000 ADL % 0.000 0.000 SC % 0.000 0.000 Forage NDF % 0.000 0.000 pendf % 0.000 0.000 NFC % 0.000 0.000 Total CHO
More informationSPRING 2017 SEMI-ANNUAL WATER QUALITY MONITORING REPORT FOR THE HALIFAX MUNICIPAL LANDFILL
SPRING 207 SEMI-ANNUAL WATER QUALITY MONITORING REPORT FOR THE HALIFAX MUNICIPAL LAFILL July 3, 207 VTDEC Project NS95-065 Prepared for: Town of Halifax P.O. Box 45 Halifax, Vermont 05358 Prepared by:
More informationOperating Manual Spectrophotometer XION 500
We reserve the right to make any changes that serve to improve the instrument. Operating Manual Spectrophotometer XION 500 BDA 451 Edition 1/2003 Dear Customer! Congratulations on your purchase of the
More informationNANOCOLOR VIS II and NANOCOLOR UV /VIS II
MACHEREY-NAGEL NANOCOLOR VIS II and NANOCOLOR UV /VIS II Smart photometry Revolutionary user experience 10 inch HD touch screen display Integrated turbidity control (NTU-Check) Intuitive and entirely icon-based
More information2017 Groundwater Quality Survey and Contaminant Trends Study Report
MCD Report 2017-16 2017 Groundwater Quality Survey and Contaminant Trends Study Report MCD staff collects a groundwater sample from a groundwater monitoring well Executive Summary To analyze groundwater
More informationAztec 600 Series Analyzers
User Guide Profibus Supplement IM/AZT6PBS Issue ABB The Company We are an established world force in the design and manufacture of instrumentation for industrial process control, flow measurement, gas
More informationTEST REPORT GUANGMANG TOY FACTORY GUANGMANG TOY FACTORY
No.202, Building A, Jingye Sanjie, Yushu Industrial Park, Guangzhou Economic & Technology Development Zone, Guangzhou, Guangdong, China Telephone :+86 (0) 20 82019555 Fax :+86 (0) 20 82019556 Email :marketing@stu-lab.com
More informationUser guide supplement PROFIBUS IM/AZT6PBS EN Rev. B. Aztec 600 Colorimetric and ion-selective analyzers
User guide supplement PROFIBUS IM/AZT6PBS EN Rev. B Aztec 600 The Company We are an established world force in the design and manufacture of measurement products for industrial process control, flow measurement,
More informationDisposable Glassware CO R N I N G A N D P Y R E X D I S P O S A B L E G L A S SWA R E D I G I TA L ST I R R I N G H OT P L AT E S...
Disposable Glassware and Equipment CO R N I N G A N D P Y R E X D I S P O S A B L E WA R E........................... 128 D I G I TA L ST I R R I N G H OT P L AT E S............. 135 Digital Stirring Hot
More informationAnalyzer. On-line Measuring
Analyzer On-line Measuring Water and wastewater treatment still require analyzers for on-line measuring, justifying their presence next to commonly more reasonable in-situ sensor systems. Especially for
More informationMEDILAB EXPORTS CONSORTIUM
Laboratory Scientific Analytical Instruments and Pharmaceutical Instruments Spectrophotometers Electrochemistry Instruments Flame Photometer Blood testing Instruments Water Analysis Kit Pharmaceutical
More information