Manual No: Revision: G. Mag Probe. Assembly Manual
|
|
- Dayna Evans
- 6 years ago
- Views:
Transcription
1 Manual No: Revision: G Mag Probe Assembly Manual
2 Notice Veeder-Root makes no warranty of any kind with regard to this publication, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Veeder-Root shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this publication. Veeder-Root reserves the right to change system options or features, or the information contained in this publication. This publication contains proprietary information which is protected by copyright. All rights reserved. No part of this publication may be photocopied, reproduced, or translated to another language without the prior written consent of Veeder-Root. DAMAGE CLAIMS / LOST EQUIPMENT Thoroughly examine all components and units as soon as they are received. If any cartons are damaged or missing, write a complete and detailed description of the damage or shortage on the face of the freight bill. The carrier's agent must verify the inspection and sign the description. Refuse only the damaged product, not the entire shipment. VEEDER-ROOT S PREFERRED CARRIER 1. Contact VR Customer Service at with the specific part numbers and quantities that were missing or received damaged. 2. Fax signed Bill of Lading (BOL) to VR Customer Service at VR will file the claim with the carrier and replace the damaged/missing product at no charge to the customer. Customer Service will work with production facility to have the replacement product shipped as soon as possible. CUSTOMER S PREFERRED CARRIER 1. It is the customer s responsibility to file a claim with their carrier. 2. Customer may submit a replacement purchase order. Customer is responsible for all charges and freight associated with replacement order. Customer Service will work with production facility to have the replacement product shipped as soon as possible. 3. If lost equipment is delivered at a later date and is not needed, VR will allow a Return to Stock without a restocking fee. 4. VR will NOT be responsible for any compensation when a customer chooses their own carrier. RETURN SHIPPING For the parts return procedure, please follow the appropriate instructions in the "General Returned Goods Policy" and "Parts Return" pages in the "Policies and Literature" section of the Veeder-Root North American Environmental Products price list. Veeder-Root All rights reserved.
3 Table of Contents Introduction Contractor Certification Requirements...1 Related Manuals...1 Mag Probe Installation Kits Standard Mag Probe Installation Kit ( XXX)...2 Low Level Mag Probe Installation Kit...2 Assembling Mag Probe Components Attaching Mag Probe Canister Spacer Rings...4 Assembling Floats onto Mag Probe Shaft...4 Attaching Cable Connector to Probe Canister...5 Figures Figure 1. Standard Mag Probe Installation Kit... 3 Figure 2. Low Level Mag Probe Installation Kit... 3 Figure 3. Installing Mag Probe Canister Spacer Rings... 4 Figure 4. Mag Probe float installation... 5 iii
4 Introduction This manual describes how to identify and assemble the components of Standard Magnetostrictive Probes - Form Number 8473 and Low Level Magnetostrictive Probes - Form Number 8493 (available selected areas only). Instructions are included for assembling floats onto the probe shaft, attaching spacer rings to the probe canister, and attaching the probe s cable to the canister. For guidelines on site preparation, instructions on installing the Mag Probe into a tank, and instructions on connecting wiring from the Mag Probe to the console, refer to the Veeder-Root Site Preparation and Installation Manual. Some of the installation kit components, such as epoxy packs, will be needed when installing the Mag Probe into the tank. Do not discard any unused parts. Contractor Certification Requirements Veeder-Root requires the following minimum training certifications for contractors who will install and setup the equipment discussed in this manual: Level 1 Contractors holding valid Level 1 Certification are approved to perform wiring and conduit routing, equipment mounting, probe and sensor installation, tank and line preparation, and line leak detector installation. Level 2/3 Contractors holding valid Level 2 or 3 Certifications are approved to perform installation checkout, startup, programming and operations training, troubleshooting and servicing for all Veeder-Root Tank Monitoring Systems, including Line Leak Detection and associated accessories. Warranty Registrations may only be submitted by selected Distributors. Related Manuals TLS-3XX Series Consoles Site Prep and Installation Manual 1
5 Mag Probe Installation Kits Standard Mag Probe Installation Kit ( XXX) Standard (8473) Mag Probes are shipped with the installation kit listed in Table 1 and shown in Figure 1. Table 1.- Standard Probe Installation Kit Contents Quantity Description Part Numbers 1 Cable X 1 2-inch* Product Float inch* Water Float X 1 4-inch* Product Float inch* Water Float X 1 Boot inch* OD Probe Canister Spacer Rings inch* OD Probe Canister Spacer Rings Cable Seal Kit (CSK) *Note: Depending on your order, this kit is shipped with either 2 or 4 floats and 3 or 4 spacer rings. Low Level Mag Probe Installation Kit Low Level (8493) Mag Probes are shipped with the installation kit listed in Table 2 and shown in Figure 2. Table 2.- Low Level Mag Probe Installation Kit Quantity Description Part Number 1 Cable, 5 feet long (standard size) inch* Product Float inch* Water Float X 1 3-inch* Product Float inch* Water Float X 1 Boot inch* OD Probe Canister Spacer Rings inch* OD Probe Canister Spacer Rings Cable Seal Kit (CSK) *Note: Depending on your order, this kit is shipped with either 2 or 4 floats and 3 or 4 spacer rings. 2
6 Mag Probe Installation Kits Low Level Mag Probe Installation Kit These two wires connect in the J-box to the two field wires from the Console Locking tabs (3) Product float Top view Probe cable connector (attaches to threaded connector on the top of probe canister) Side view 4-inch spacer ring Locking Water float (optional) 4-Inch Floats Note: your Mag Probe installation kit will contain 2-inch or 4-inch floats as per your order. Cable Boot Wire nuts Tie wrap Cord Grip Nut Bushing 1/2"-14 NPSL threads Body Note: watch orientation of bevels and tapers when assembling these cord grip components..4" Product float Epoxy sealant 1/2"-14 NPT threads Cord Grip Fitting.6" probes\pbinkit1.eps Cable Seal Kit Water float (optional) 2-Inch Floats Figure 1. Standard Mag Probe Installation Kit These two wires connect in the J-box to the two field wires from the console Tie wrap (CSK) Locking tabs (3) Product float Product float Wire nuts (CSK) Top view Probe cable connector (attaches to threaded connector on the top of probe canister) Note: your Mag Probe installation kit will contain 3-inch or 4-inch rings as per your order. Side view 3-inch spacer ring Water float (optional) Water float (optional) Cord Grip Nut Bushing 1/2"-14 NPSL threads Body 1/2"-14 NPT threads Cable Cord Grip Fitting (CSK) Note: watch orientation of bevels and tapers when assembling these cord grip components..4".6" Epoxy sealant (CSK) Locking tabs (3) Top view Side view 4-inch spacer ring 3-Inch Floats Boot Locking tabs (3) 2-Inch Floats Note: your Mag Probe installation kit will contain 2-inch or 3-inch floats as per your order. probes\pbinkit2.eps Figure 2. Low Level Mag Probe Installation Kit 3
7 Assembling Mag Probe Components Attaching Mag Probe Canister Spacer Rings 1. Open the Mag Probe shipping carton so that you have access to the probe. Also open the installation kit. 2. Following the instructions in Figure 3, install the proper spacer rings (3 or 4 ) onto the probe canister (although outwardly different, both the 3 and 4 rings are attached in the same way onto the canister). Top spacer ring (locking tabs up) Locking tab (3) Cut (3) After aligning spacer ring locking tabs over cuts, slide the ring down until its tabs rest on the bottom of the cuts. Twist spacer ring in either direction until locking tabs seat in notches. Notch (3) Up Canister Before sliding floats and boots over probe shaft, slide spacer ring over bottom of canister until locking tabs snap into groove. Bottom spacer ring (locking tabs down) Probe shaft Figure 3. Installing Mag Probe Canister Spacer Rings Assembling Floats onto Mag Probe Shaft The Product floats, Water Floats (if ordered), and Boots from Mag Probe Installation Kits are assembled on 8473/ 8493 probe shafts in the exact sequence and orientation shown in Figure 4. Note: Failure to snap the boot locking tabs into the locking indents on the probe shaft could cause the boot and float(s) to fall into the tank. Water floats must installed, if ordered, for the Mag Probe to operate correctly. Handle the Mag Probe carefully. Striking or dropping the probe will result in loss of calibration and could cause permanent damage. 4
8 Assembling Mag Probe Components Attaching Cable Connector to Probe Canister 8473 MAG PROBE FLOAT OPTIONS Up 4-Inch Floats - OR - Product float - shaft first. 2-Inch Floats Product float - shaft first. Boot tab locking indents Water float - (Optional) shaft second. Water float - (Optional) shaft second. Bottom of probe shaft Boot - Boot MAG PROBE FLOAT OPTIONS 3-Inch Floats - OR - 2-Inch Floats - OR - LPG 2-Inch Float Product float - shaft first. Product float - shaft first. Magnet down Up Boot tab locking indents Bottom of probe shaft Water float - (Optional) shaft second. Boot - Water float - (Optional) shaft second. Boot - Boot - probes\comboflt.eps Figure 4. Mag Probe float installation Attaching Cable Connector to Probe Canister Attach the connector end of the Mag Probe cable to the threaded connector on top of the probe canister and tighten down the integral nut. This completes the Mag Probe assembly. Save the remaining kit components. They will be needed to install the Mag Probe into the tank (reference the console Site Prep and Installation manual). 5
9 For technical support, sales or other assistance, please visit:
Manual No: Revision: E. Mag Plus Probe. Assembly Guide
Manual No: 577013-744 Revision: E Mag Plus Probe Assembly Guide Notice Veeder-Root makes no warranty of any kind with regard to this publication, including, but not limited to, the implied warranties of
More informationTLS-3XX Series Consoles
Manual No: 0-0 Revision: A TLS-XX Series Consoles Display Replacement Guide Notice Veeder-Root makes no warranty of any kind with regard to this publication, including, but not limited to, the implied
More informationManual No: Revision: D. Mag Retrofit Probe. Installation Guide
Manual No: 577013-791 Revision: D Mag Retrofit Probe Installation Guide Notice Veeder-Root makes no warranty of any kind with regard to this publication, including, but not limited to, the implied warranties
More informationVapor Monitor Interface Module
Manual No: 577013-951 Revision: A Vapor Monitor Interface Module Installation Guide Notice Veeder-Root makes no warranty of any kind with regard to this publication, including, but not limited to, the
More informationManual No: Revision: A. TLS-4XX Consoles. Upgrade Installation Instructions
Manual No: 577013-961 Revision: A TLS-4XX Consoles Upgrade Installation Instructions Notice Veeder-Root makes no warranty of any kind with regard to this publication, including, but not limited to, the
More informationManual No: Revision: F. Relay Output Modules. Installation Guide
Manual No: 576013-614 Revision: F Relay Output Modules Installation Guide Notice Veeder-Root makes no warranty of any kind with regard to this publication, including, but not limited to, the implied warranties
More informationIFSF Interface Module
Manual No: 577013-607 Revision: C IFSF Interface Module Installation Guide Notice Veeder-Root makes no warranty of any kind with regard to this publication, including, but not limited to, the implied warranties
More informationINSTALLATION and QUICK HELP FOR TLS CONSOLE INTERFACE TO THE VEEDER-ROOT EMR4 DATALINK USING AN XTEND 900 MHZ WIRELESS MODEM Rev.
INTRODUCTION This Installation and Quick Help Guide contains the necessary information to connect a wireless modem to a TLS-300, TLS-350, TLS4, or TLS-450PLUS console and obtain the tank information in
More informationXTEND 900 MHZ WIRELESS MODEM For use with VEEDER-ROOT EMR4 DATALINK INSTALLATION INSTRUCTIONS Manual , Rev. A
INTRODUCTION This installation guide contains the necessary information to connect the wireless modems to the EMR4 Interconnect Box and the office computer for running the EMR4 DataLink program. For specific
More informationTLS-450 To TLS-450PLUS Console
Manual No: 770-08 Revision: A TLS-0 To TLS-0PLUS Console Upgrade Instructions Notice Veeder-Root makes no warranty of any kind with regard to this publication, including, but not limited to, the implied
More informationTLS-350 Series Consoles
Manual No: 576013-637 Revision: M TLS-350 Series Consoles Board and Software Replacement Notice Veeder-Root makes no warranty of any kind with regard to this publication, including, but not limited to,
More informationTLS-450/TLS-450PLUS Consoles
Manual No: 577013-934 Revision: E TLS-450/TLS-450PLUS Consoles Site Prep Certification Manual Notice Veeder-Root makes no warranty of any kind with regard to this publication, including, but not limited
More informationInstalling the A4504A PMC Bridge Adapter and A4509A Expansion Adapter. HP Part No. A Edition E1197 Printed in U.S.A.
Installing the A4504A PMC Bridge Adapter and A4509A Expansion Adapter HP Part No. A4504-90601 Edition E1197 Printed in U.S.A. Hewlett-Packard Co. 1997 Printing History First Printing: November 1997 UNIX
More informationTLS-4XX Setup and Operation
Manual No: 577013-940 Revision: D TLS-4XX Setup and Operation Screens Manual Notice Veeder-Root makes no warranty of any kind with regard to this publication, including, but not limited to, the implied
More informationPit Transition with 24" Fan Installation and Operators Instruction Manual
Pit Transition with 4" Fan Installation and Operators Instruction Manual z Fan and Fan Framing Dimensions Shutter Fan " [8. cm] 6" [9.4 cm] 6-/4" [9. cm] Cone Fan " [5. cm] 4-/6" [88.4 cm] 75-/" [9.8 cm]
More informationTLS4/8601 Series Consoles
Manual No: 577014-043 Revision: C TLS4/8601 Series Consoles Software/Hardware Upgrade & Replacement Manual Notice Veeder-Root makes no warranty of any kind with regard to this publication, including, but
More informationINSTALLATION INSTRUCTIONS YAMAHA Speaker Adapter Accessory Model: PAC-Y2
INSTALLATION INSTRUCTIONS YAMAHA Speaker Adapter Accessory BEFORE YOU BEGIN CAUTION! The instructions provided in this document outline the installation of the PAC-Y2 Lateral Shift Accessory to specific
More informationPressurized Line Leak Controller Module. For Veeder-Root TLS-350/350R Systems
Installation Manual Pressurized Line Leak Controller Module For Veeder-Root TLS-350/350R Systems Manual Number 576013-499, Revision C Notice Veeder-Root makes no warranty of any kind with regard to this
More informationRack Power Distribution Unit AP7530, AP7540
Rack Power Distribution Unit AP7530, AP7540 Description This booklet provides information on installing and operating the singlephase Rack Power Distribution Units (PDUs) AP7530 and AP7540. AP7530 AP7540
More informationManual No: Revision: D. TLS-XB Expansion Box. Site Prep and Installation Manual
Manual No: 577014-033 Revision: D TLS-XB Expansion Box Site Prep and Installation Manual Notice Veeder-Root makes no warranty of any kind with regard to this publication, including, but not limited to,
More informationKeysight Technologies N9020B MXA Signal Analyzer
Keysight Technologies N9020B MXA Signal Analyzer Analog Baseband IQ Inputs (Option BBA) Upgrade Kit Notice: This document contains references to Agilent. Please note that Agilent s Test and Measurement
More informationInstalling the A4505A PCI Module Upgrade. HP Part No. A Edition E0297 Printed in U.S.A.
Installing the A4505A PCI Module Upgrade HP Part No. A4500-90603 Edition E0297 Printed in U.S.A. Hewlett-Packard Co. 1997 Printing History First Printing: February 1997 UNIX is a registered trademark in
More informationInstalling the A4979A PMC Graphics Card. HP Part No. A Edition E1098 Printed in U.S.A.
Installing the A4979A PMC Graphics Card HP Part No. A4979-90602 Edition E1098 Printed in U.S.A. Hewlett-Packard Co. 1998 Printing History First Printing: July 1998 Latest Printing: October 1998 UNIX is
More informationEnable-IT 828W Weatherproof Professional Grade PoE Extender Unit Quickstart Guide
! Enable-IT 828W Weatherproof Professional Grade PoE Extender Unit Quickstart Guide All Rights Reserved 1997-2017 Enable-IT, Inc. INSTALLING THE 828W WEATHERPROOF POE EXTENDER Installation The Enable-IT
More informationTECHKNOW, INC. Kiosk Order Confirmation System INSTALLATION MANUAL. Revision Date: July 11, 2012 Part # Version 3.2
document Page 1 of 18 TECHKNOW, INC Kiosk Order Confirmation System INSTALLATION MANUAL Revision Date: July 11, 2012 Part # Version 3.2 Techknow, Inc. 393 Mayfield Road Duncan, SC 29334 www.gotechknow.com
More informationCOOPER POWER SERIES. 600 A U-OP visible break connector system operation instructions. Deadbreak Apparatus Connectors MN650022EN
Deadbreak Apparatus Connectors MN650022EN COOPER POWER Effective March 2016 Supersedes S600-14-1 June 2010 SERIES 600 A U-OP visible break connector system operation instructions DISCLAIMER OF WARRANTIES
More informationEnable-IT 821 Ethernet Extender Quickstart Guide Professional Grade Networking
! Enable-IT 821 Ethernet Extender Quickstart Guide Professional Grade Networking All Rights Reserved 1997-2017 Enable-IT, Inc. INSTALLING THE 821 ETHERNET EXTENDER The Enable-IT 821 Ethernet Extenders
More informationSPORTSMAN PRICE LIST
H I G H P E R F O R M A N C E F O R G E D P I S T O N S TM ORDERING PRICE LIST Effective 01/01/2008 Prices Subject to Change without notice. Drop Ships will incur a $15.00 Fee EXPRESS SHELF ORDERS PAYMENT
More informationTSP-LL2 Magnetostrictive Probe
TSP-LL2 Magnetostrictive Probe Installation Franklin Fueling Systems 3760 Marsh Rd. Madison, WI 53718 USA Tel: +1 608 838 8786 800 225 9787 Fax: +1 608 838 6433 www.franklinfueling.com Safety Always lock
More informationLINEAR ACTUATOR CONTROL Use with NEW LEADER 7 manual
MANUAL FOR MODEL LINEAR ACTUATOR CONTROL Use with NEW LEADER 7 manual INSTALLATION OPERATION TROUBLESHOOTING PARTS LIST This unit may have been built with SPECIAL FEATURES. Provide SERIAL NUMBER when ordering
More information4300 WINDFERN RD #100 - HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!
4300 WINDFERN RD #100 - HOUSTON TX 77041-8943 VOICE (713) 973-6905 - FAX (713) 973-9352 web: www.twrlighting.com IMPORTANT!!! PLEASE TAKE THE TIME TO FILL OUT THIS FORM COMPLETELY. FILE IT IN A SAFE PLACE.
More informationInstallation Guide for Flex Tap
Installation Guide for Flex Tap 800-0216-001 Rev. A 9/12 Contents Introduction....1 Key Features....2 About This Guide....3 Unpacking and Inspection....3 Rack Mounting the Flex Tap Panel....3 Loading the
More informationSERVICE MANUAL MODEL SSW-321-X
SSW-321-X-ISSUE 4.0 SERVICE MANUAL FOR MODEL SSW-321-X STAINLESS STEEL WALL TELEPHONE Serving the Telephone Industry Since 1930 Communication Equipment 519 W South Park Street & Engineering Company Okeechobee,
More informationCD-ROM Box Enclosure
CD-ROM Box Enclosure Installation Guide For Models: VP-6020 VP-6028 VP-6022 VP-6029 VP-6023 VP-6048 VP-6024 VP-6049 TM We are your DataBridge http://www.vipower.com Table of Contents 1-1 Introduction...
More informationCUBE Micro Station User Guide
CUBE Micro Station User Guide Models TVS10AC CUBE Micro Station - User Guide 1 of 23 How To Use This Guide This User Guide is a resource to provide you guidelines and best practices as you begin using
More informationMobilcomm 1211 West Sharon Road, Cincinnati, OH 45240
BRICS Princeton Road Hamilton, Ohio 45011 Matt Franke, Bill Vedra Attn: Email: Reference: Motorola XTS1500 Pricing Quote: Issued: Expires: Phone: Fax: 901-16854 10/3/2012 11/15/2012 513-785-1299 Item Product
More information* * Agilent Power Distribution Unit (PDU) Installation Guide
Agilent Power Distribution Unit (PDU) Installation Guide For use with Agilent PDU kits and PDU installation kits for Agilent instrument racks June 2008 Edition 7 E0608 *5000-0039* 5000-0039 Notice The
More information7" Touch Screen Display
7" Touch Screen Display Installation Guide Contents Minimum Requirements...1 Select a Location...1 Initial Setup...2 Unboxing...2 Installation...3 Prepare the Panel...3 Install the Mounting Plate...3 Mount
More information5000 Series Bench Scale Platforms
Service / Installation Manual 5000 Series Bench Scale Platforms 51245 2010-2013 by Fairbanks Scales, Inc. Revision 3 07/13 All rights reserved Amendment Record 5000 SERIES BENCH SCALE PLATFORMS SERVICE
More informationLevelMaster Start-Up Guide
LevelMaster Start-Up Guide MEASUREMENT & CONTROL SYSTEMS Intellectual Property & Copyright Notice 2009 by ABB Inc., ( Owner ), Bartlesville, Oklahoma 74006, U.S.A. All rights reserved. Any and all derivatives
More information36'' & 48'' E-Z Shutter Fan Installation & Operator s Instruction Manual
6'' & 8'' E-Z Shutter Fan Installation & Operator s Instruction Manual MV-8B 8/99 August 999 MVB Chore-Time Warranty 6'' 8'' EZ Shutter Fans Chore-Time Warranty Chore-Time Equipment warrants each new product
More informationAlphaServer DS20 Ultra SCSI Internal StorageWorks Shelf Configuration Guide
AlphaServer DS20 Ultra SCSI Internal StorageWorks Shelf Configuration Guide Order Number: EK-H8253-IN. A01 Compaq Computer Corporation Maynard, Massachusetts First Printing, November 1998 The information
More informationCR Getting Started Guide
CR Getting Started Guide Table of Contents THE CR TESTER... 1 Introduction... 1 Parts List... 1 Add-On Scanner Parts List... 1 SOFTWARE INSTALLATION GUIDE... 3 Requirements for a Station or Network Server...
More informationInstallation Note. Enhanced Memory Upgrade Kit (Option B72) for Agilent ESA-E Series and ESA-L Series Spectrum Analyzers
Installation Note Enhanced Memory Upgrade Kit (Option B72) for Agilent ESA-E Series and ESA-L Series Spectrum Analyzers Part Number E4401-90498 Supersedes: E4401-90332 Printed in USA July 2005 Notice.
More informationCOOPER POWER SERIES. RS-485 digital communications accessory board installation and operation instructions. Voltage Regulators MN225074EN
Voltage Regulators MN225074EN Effective March 2017 Supersedes January 2012 (S225-40-7) RS-485 digital communications accessory board installation and operation instructions COOPER POWER SERIES DISCLAIMER
More informationSAVE THESE INSTRUCTIONS
and Height Mounts Assembly, Installation and Operating Instructions Model Nos. QL, QLA, ARM250, QLM6 and QLAM6 NOTE: Check all parts for shipping damage. In case of shipping damage, DO NOT use. Contact
More informationTower to Rack and Rack to Tower System Conversion Guide
Tower to Rack and Rack to Tower System Conversion Guide HP Workstation zx6000 HP Server rx2600 Manufacturing Part Number : A7857-90017 Edition E0802 Copyright 2002 Hewlett-Packard Company. Legal Notices
More informationCERTIFIED MAIL LABELS TERMS OF USE and PRIVACY POLICY Agreement
CERTIFIED MAIL LABELS TERMS OF USE and PRIVACY POLICY Agreement Welcome to Certified Mail Envelopes and Certified Mail Labels web sites (the Site ) a website, trademark and business name owned and operated
More informationInstallation Instructions
Model: Page: 1 of 6 EEOS130A Sun Machine 450 EL Unit Setup Installation Instructions INSTALLATION MUST BE PERFORMED BY QUALIFIED EQUISERV PERSONNEL ONLY INSTALLATION OVERVIEW: The Installation Instructions
More informationManual No: Revision: B. Software Version 2.0. Inform.NET. Bulk Load File Format
Manual No: 577014-016 Revision: B Software Version 2.0 Inform.NET Bulk Load File Format Notice Veeder-Root makes no warranty of any kind with regard to this publication, including but not limited to, the
More informationWhen any of the following symbols appear, read the associated information carefully. Symbol Meaning Description
Uni-I/O Modules Installation Guide UID-0808THS Uni-I/O is a family of Input/Output modules that are compatible with the UniStream control platform. This guide provides basic installation information for
More informationFA-2448 SIX POSITION Filter Wheel
15 Discovery Way, Acton, MA 01720 Phone: (978)263-3584, Fax: (978)263-5086 Web Site: www.acton-research.com Operating Instructions Acton Research Corporation FA-2448 SIX POSITION Filter Wheel Rev. 3.05.17
More informationPrint Mechanism Maintenance Kit
Print Mechanism Maintenance Kit Installation Instructions This kit includes the parts and documentation necessary to install the print mechanism maintenance kit in the following printers: ZT0 ZT0 ZT0 Read
More information4300 WINDFERN RD #100 HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!
4300 WINDFERN RD #100 HOUSTON TX 77041-8943 VOICE (713) 973-6905 FAX (713) 973-9352 web: www.twrlighting.com IMPORTANT!!! PLEASE TAKE THE TIME TO FILL OUT THIS FORM COMPLETELY. FILE IT IN A SAFE PLACE.
More informationUniversal Tablet Mount Accessory for Flex TechBridge
Assembly Instructions Universal Tablet Mount Accessory for Flex TechBridge Universal Tablet Mount Accessory Universal Tablet Mount Accessory mounted on Flex Arm CONTENTS Important User Information...........................2
More informationInstallation Note. Agilent Technologies ESA-E Series Spectrum Analyzers High Stability Frequency Reference (Option 1D5) Retrofit Kit
Installation Note Agilent Technologies ESA-E Series Spectrum Analyzers High Stability Frequency Reference (Option 1D5) Retrofit Kit Part Number E4401-90484 Printed in USA January 2013 Notice. The information
More informationWhen any of the following symbols appear, read the associated information carefully. Symbol Meaning Description
Uni-COM Modules Installation Guide UAC-01RS2,UAC-02RS2,UAC-02RSC Uni-COM is a family of communication modules that are compatible with the UniStream control platform. This guide provides basic installation
More informationTABLE OF CONTENTS SECTION 1 TABLETOP CONFIGURATION SECTION 2 TABLETOP CONFIGURATION ACCESSORIES SECTION 3 SLIDE CONFIGURATION
S6 USER S MANUAL TABLE OF CONTENTS SECTION 1 TABLETOP CONFIGURATION SECTION 2 TABLETOP CONFIGURATION ACCESSORIES SECTION 3 SLIDE CONFIGURATION SECTION 4 SLIDE CONFIGURATION ACCESSORIES SECTION 5 RACK MOUNT
More informationZonit μats TM Users Guide μats1-lv Version 1.2
Zonit μats TM Users Guide μats1-lv Version 1.2 Table of Contents Product Overview...2 Pre-Installation Considerations...2 Product Features...3 Installation...4 Optional Accessories...4 μats TM Operational
More informationInstruction and Operation Manual. CRMS Contact Resistance Measurement System. Model Number Caution!
Instruction and Operation Manual CRMS Contact Resistance Measurement System Model Number 16574-00 Caution! Be sure to read and become thoroughly familiar with the entire contents of this manual before
More informationDSLR Camera Cage Shoulder Rig Kit (FC-03)
FILMCITY DSLR Camera Cage Shoulder Rig Kit 1 DSLR Camera Cage Shoulder Rig Kit (FC-03) I N S T R U C T I O N M A N U A L All rights reserved. No part of this document may be reproduced, stored in a retrieval
More informationIoline 300/350HF System
Quick Start Guide Ioline 300/350HF System User Notice Trademarks Ioline is a trademark of Ioline Corporation. Other product names, logos, designs, titles, words or phrases mentioned within this publication
More informationMULTI-MOUNT. Assembly Manual
MULTI-MOUNT Assembly Manual CONTENTS Introduction 1.1 Hardware Requirements... 1 1.1.1 Compatible Systems 1.1.2 Supported Drives 1.1.3 Required Tools 1.2 Package Contents... 1 1.3 About This Manual...
More informationMODBUS MANUAL For the AccUView UV Transmission Monitor
MODBUS MANUAL For the AccUView UV Transmission Monitor HF scientific, inc. 3170 Metro Parkway Ft. Myers, FL 33916 Phone: 239-337-2116 Fax: 239-332-7643 E-Mail: info@hfscientific.com Website: www.hfscientific.com
More informationINSTALLATION INSTRUCTIONS. Decorative Display Frame and Optical Filter Kit. 32", 42", and 50"
INSTALLATION INSTRUCTIONS Decorative Display Frame and Optical Filter Kit 32", 42", and 50" 32", 42", and 50" Installation Instructions DISCLAIMER CSAV, Inc., and its affiliated corporations and subsidiaries
More informationOperation Manual MODEL 2TX. 2-wire Isolated ph/orp Transmitter
Operation Manual MODEL 2TX 2-wire Isolated ph/orp Transmitter 0 2TX CONTENTS INITIAL INSPECTION.....2 INTRODUCTION......2 ASSEMBLY...3 PREPARATION....4 CONNECTING THE ELECTRODE...4 CONNECTING THE TEMPERATURE
More informationARC Magnetic Capping Headsets
ARC Magnetic Capping Headsets P-2016-WE ARC Service & Installation Instructions An Altra Industrial Motion Company ARC Installation Procedure Wrench flats Customer Supplied Chuck Knock-out Rod Figure 1
More informationEVO-TM2A EVO-TM2B Touch Screen Monitor
User Manual Revision v1.3 Dec. 2010 EVO-TM2A EVO-TM2B Touch Screen Monitor Copyright 2010 August All Rights Reserved Manual Version 1.3 Part Number: The information contained in this document is subject
More informationAURA SSD FOR MAC PRO. Installation Guide
AURA SSD FOR MAC PRO Installation Guide CONTENTS Introduction... 1 1.1 System Requirements 1.2 Package Contents 1.3 About This Manual Installation... 2 2.1 Preparing the Mac Pro 2.2 Installing the Aura
More informationInstallation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.
Vision OPLC Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V290-19-C30B and V290-19-T40B. General Description Vision OPLCs are programmable
More informationVIDEO Camera Cage WITH MATTE BOX FC-65-N
VIDEO Camera Cage WITH MATTE BOX FC-65-N I N S T R U C T I O N M A N U A L All rights reserved No part of this document may be reproduced, stored in a retrieval system, or transmitted by any form or by
More informationDosage Delivery System Operation Manual Document: Revision: A Distek, Inc. Operation Manual
Dosage Delivery System Operation Manual Document: 3800-010 Revision: A Operation Manual Dosage Delivery System Operation Manual Document 3800-010 Distek, Inc. 121 North Center Dr. North Brunswick, NJ 08902
More informationi-series Videoconference Fixture
TM i-series Videoconference Fixture Operating Instructions 580 Mayer Street, Building #7, Bridgeville, PA 15017 phone 412.206.0106 fax 412.206.0146 www.brightlines.com 2013 Brightline, L.P. Safety To prevent
More informationInstallation Note. Agilent PSA Series Spectrum Analyzers Secure Memory Erase, Option 117
Installation Note Agilent PSA Series Spectrum Analyzers Secure Memory Erase, Option 117 Part Number E4440-90323 Printed in USA July 2006 Notice. The information contained in this document is subject to
More informationEMD-100 ELECTRIC DISPERSER
EMD-100 ELECTRIC DISPERSER OWNERS MANUAL EMD-100 ELECTRIC DISPERSER Warranty: Our products are guaranteed against defective materials and workmanship. We will repair or replace such items as may prove
More informationWhat s in the box. SUP paddle sensor. Paddle sensor mounting track. Charger. USB cable. In your Motionize SUP kit you will find:
User's Manual 1 What s in the box In your Motionize SUP kit you will find: SUP paddle sensor Paddle sensor mounting track Charger USB cable 2 Android & ios Requirements Android 5 or newer. iphone 5 or
More informationTCD600 OPEN LOOP TENSION CONTROLLER INSTALLATION, OPERATION MANUAL ADDENDUM (NETWORK FEATURE)
TCD600 OPEN LOOP TENSION CONTROLLER INSTALLATION, OPERATION MANUAL ADDENDUM (NETWORK FEATURE) INTRODUCTION Nexen s TCD600 is a LonWorks compatible controller. It has a unique networking feature which enables
More informationAgilent Technologies 11667A DC to 18 GHz Power Splitter
Agilent Technologies 11667A DC to 18 GHz Power Splitter User's and Service Guide REPRODUCTION AND DISTRIBUTION OF THIS TECHNICAL MANUAL IS AUTHORIZED FOR GOVERNMENT PURPOSES. AgilentTechnologies User's
More informationLimit Switch Connectors
CSM_LimitSwitch_Connector_DS_E Connectors (SC Series) Cabtire cables and flexible tubes with various diameters are used to connect machine tools and controllers with Limit Switches. To ensure the watertightness
More informationOilCop Component Wiring Installation Manual
OilCop Component Wiring Installation Manual This info sheet contains important information. READ AND KEEP FOR REFERENCE. 2311 S. Edwards Wichita, KS 67213 TEL: 316-943-5477 FAX: 316-943-4760 TOLL FREE:
More informationParts and Service Manual IMCO
XXTREME ADVANTAGE Gimbal Parts and Service Manual IMCO 510 East Arrow Highway San Dimas, CA 91773 (800) 899-8058 (909) 592-6162 Fax (909) 592-6052 www.imcomarine.com email info@imcomarine.com TABLE OF
More informationMITSUBISHI ELECTRONICS AMERICA, INC.
8.0 Product Support Mitsubishi Electronics position as an industry leader cannot be maintained by only developing new products. Mitsubishi also constantly strives to enhance product support and customer
More information1. If the impaired node is part of an HA pair, disable automatic giveback from the console of the healthy node:
AFF A200 systems Replacing DIMMs You must replace a DIMM in the controller module when your system registers an increasing number of correctable error correction codes (ECC); failure to do so causes a
More informationQuick Start Guide Ioline StudioJet
Quick Start Guide Ioline StudioJet User Notice Trademarks Ioline StudioJet is a trademark of Ioline Corporation. HP is a trademark of the Hewlett-Packard Company. Other product names, logos, designs, titles,
More informationInstallation Guide. English. HP LaserJet 5, 5M and 5N Printer Duplex Printing Accessory (C3920A)
Installation Guide English HP LaserJet 5, 5M and 5N Printer Duplex Printing Accessory (C3920A) Copyright Hewlett- Packard Company 1996 All Rights Reserved. Reproduction, adaptation, or translation without
More informationAdapter Kit for PanelView 1200/1200e Touch Screen Terminal Cutout
Installation Instructions Adapter Kit for PanelView 1200/1200e Touch Screen Terminal Cutout Catalog Numbers 2711-NR5T, 2711P-RAT12E2 Topic Page About This Publication 1 Important User Information 2 About
More informationZebra XiIII-Series Printer Safety and Quick Reference Guide
Zebra XiIII-Series Printer Safety and Quick Reference Guide GB Contents Specifications...75 Electrical...75 Environmental Range...75 Fuses...75 Warnings...76 Installation...76 Use of Shielded Data Cables...76
More informationZ Series and S4M Ribbon/Head Open Sensor Assembly
Z Series and S4M Installation Instructions This kit includes the parts and documentation necessary to install the ribbon/head open sensor assembly into the following printers: Z Series (Z4M, Z6M, Z4Mplus,
More informationThis guide provides basic information for Unitronics Models 230/260/280/290 (Non-color Screens).
Vision OPLC Installation Guide Models 230/260/280/290 (Non-color Screens) This guide provides basic information for Unitronics Models 230/260/280/290 (Non-color Screens). General Description Vision OPLCs
More informationDSLR Camera Cage Carbon Fiber Shoulder Rig Kit ( FC-02-CF )
FILMCITY DSLR Camera Cage Carbon Fiber Shoulder Rig Kit 1 DSLR Camera Cage Carbon Fiber Shoulder Rig Kit ( FC-02-CF ) I N S T R U C T I O N M A N U A L All rights reserved. No part of this document may
More informationAquaController Apex Probe Module 2
AquaController Apex Probe Module 2 Setup Guide Table of Contents PROBE MODULE 2 INTRODUCTION... 1 FEATURES... 1 PHYSICAL INSTALLATION... 1 Initial Connections... 1 Startup... 2 VERIFY THE INSTALLATION...
More informationModel A4268A FWD SCSI Adapter Installation and Service Guide. Embedded Systems Operation Part No. A Edition E1097
Model A4268A FWD SCSI Adapter Installation and Service Guide Embedded Systems Operation Part No. A4268 90601 Edition E1097 Hewlett Packard Co. 1995, 1997 First Printing: April 1995 Last Printing: October
More informationAmphenol. 608 Series. Amphenol Limited. Design Features. Circular Environmental Connectors Approved to BS9522 F0020 (Pattern 608)
Amphenol 608 Series Circular Environmental Connectors Approved to BS9522 F0020 (Pattern 608) CE30 Design Features Keyway Polarisation. Ni Aluminium Bronze Shells. Threaded Anti Vibration coupling mechanism.
More informationOmnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual
Omnitron Systems Technology, Inc. 1 iconverter 19-Module Managed Power Chassis User s Manual 27 Mauchly, #201, Irvine, CA 92618 Phone: (949) 250-6510; Fax: (949) 250-6514 2 Omnitron Systems Technology,
More informationMK-MANTA III OWNER S MANUAL PARTS LIST & OPERATING INSTRUCTIONS
www.mkdiamond.com MK-MANTA III OWNER S MANUAL PARTS LIST & OPERATING INSTRUCTIONS Revision 202 08.2012 Manual Part# 161117 Caution: Read all safety and operating instructions before using this equipment.
More informationCR87B TEMPERATURE RECORDER
CR87B TEMPERATURE RECORDER Sealed Unit Parts Co., inc. PO Box 21, 2230 Landmark Place, Allenwood, NJ 08720 USA Phone: 732-223-6644 Fax: 732-223-1617 www.supco.com info@supco.com 19204 INTRODUCTION The
More informationV E2B Snap-in I/O Module
i4 Automation Ltd - 01480 395256 V200-18-E2B Snap-in I/O Module The V200-18-E2B plugs directly into the back of compatible Unitronics OPLCs, creating a selfcontained PLC unit with a local I/O configuration.
More informationIt s Under Control. Installation and Operation Guide CPB-1. Control Port Connecting Block V 1.1
Installation and Operation Guide 70-210043-17 V 1.1 Copyright 2008 Remote Technologies Incorporated All rights reserved. 2 DECLARATIONS 117 612 914 DECLARATION OF CONFORMITY (DOC) The Declaration of Conformity
More informationProliphix EPA-60 Installation Guide
Proliphix EPA-60 Installation Guide Rev 1.2 Page 2 of 5 Installation CAUTION THE EPA-60 SHOULD ONLY BE POWERED WITH THE PROLIPHIX POWER SUPPLY INCLUDED WITH THE EPA-60. DO NOT POWER THE EPA-60 WITH ANY
More informationBasketball Shot Clock Set LX2180 Manual
Basketball Shot Clock Set LX2180 Manual 72 Industrial Boulevard Wrightsville, GA 31096 Phone: (800) 445-7843 Fax: (800) 864-0212 www.electro-mech.com LX2180 Revision 5 February 8, 2013 Table of Contents
More information