Power. Ordering Guide

Size: px
Start display at page:

Download "Power. Ordering Guide"

Transcription

1

2 Table of Contents Overview... 3 Key Benefits... 3 Panels GMT Fuse Panels... 5 Strategic... 5 Standard... 6 GMT Fuse Panel Matrix KLM Fuse Panels... 9 Strategic... 9 Standard... 9 KLM Fuse Panel Matrix TPA Fuse Panels...10 Strategic...10 Standard...10 TPA Fuse Panel Matrix Circuit Breaker Panels...12 Strategic...12 Standard...12 Circuit Breaker Panel Matrix...13 T009-5xx0xxxxxxx Family Configuration Guide Demarcation Panels...15 Strategic...15 Standard...15 Demarcation Panel Matrix...16 Appendix...17 i. GMT Fuses...17 ii. KLM and TPA Fuses...17 iii. TPS and TLS Fuses...18 iv. Asymmetrical Breakers...18 vii. Symmetrical Breakers...19 viii. Instantaneous Trip Circuit Breakers...20 ix. Mid-Trip Circuit Breakers

3 Overview Power requirements can vary from location to location, with distribution to different types of network elements the primary driver. Network architects and engineers require a broad range of options including input amperage ratings, fuse types and amperages, circuit breakers and panel design to find the best fit for their applications. Amphenol Telect power products ensure long-term network performance and optimal protection of active gear. We are a market leader in secondary and tertiary DC power distribution, providing the highest quality and broadest portfolio of products. Over the last 10 years, Amphenol Telect has sold more than 250,000 panels with zero in-service failures. Key Benefits Quality engineered product that will not fail Broad choice of DC power distribution panels with industry-leading density Best-in-industry warranty: five-year standard UL/NEBS tested Exceptional service and support Panels GMT GMT fuse panels accommodate a wide variety of inputs, from 15A up to 100A. Panels support up to 20A fuse positions to handle a wide range of equipment, universal operating voltage (±24/-48 VDC) and special features such as noise filtering or load sharing. They fit any network environment from traditional central offices to customer premise and wireless applications. KLM The KLM fuse panels allow engineers to transition to higher current demands (up to 30A) while maintaining traditional low-current distribution. Most KLM panels are combination KLM/GMT panels that take up just one rack unit of space and support up to 4x4 KLM/GMT distribution per bus. Higher density panels and load-sharing options are available to fit low-current distribution network environments. 3

4 TPA The TPA fuse panel offers industry-leading high-density fuse protection for both high-current and lowcurrent equipment in one space-saving panel. It s ideal for managing power to routers, DSLAMs, optical MUXes and other active equipment. Inputs range from 100A to 350A, allowing their use across the full range of secondary distribution and the lower range of battery distribution. A minimum of 8 total outputs of GMT and TPA per dual feed, provides an excellent balance of capacity and distribution with output ranges from <1A to 50A. Circuit Breaker High Current High-current circuit-breaker panels allows engineers to bring power management closer to network elements. Ranging from 200A to 600A inputs, Amphenol Telect circuit breaker panels provide flexibility for primary and secondary distribution when a full battery distribution frame is not required. Panels can also support TPS and TLS fuses using a TFD fuse holder. This offers even more flexibility and choice for powering network gear. Low Current This factory-configured panel is pre-loaded and ready for deployment. The low-current circuit breaker panel offers the convenience of circuit breakers for traditional power distribution and flexibility with a broad range of factory supporting up to 20A per output to meet many application needs. Its compact 1RU design maximizes rack space. Demarcation Amphenol Telect demarcation circuit-breaker panels provide a demarcation point for large power feeds between primary distribution and network equipment. Panels range from one rack unit supporting four 100A inputs to two rack units supporting up to eight 125A inputs. Almost all panels accommodate both TFD fuse holders and bullet-style circuit breakers. 4

5 1. GMT Fuse Panels Strategic Part 60GMT10 Description DUAL,60A,10/10 GMT,ALARM,+\-24-48VDC GMT05FA GMT10 HPGMT10 HPGMT10FA HPGMT15 HPGMT20 DUAL 5/5 GMT TFA,50A, UNIVERSAL +/-24/48VDC 60A MAX,DUAL 10/10 20A GMT,SCREW CLAMP,R CVR,UNIVERSAL VDC,BAY ALARM, 1 RU,UNIVERSAL MOUNT 100A MAX,DUAL 10/10 20A GMT,STUD/SCREW,R CVR,UNIVERSAL VDC,BAY ALARM,1 RU,UNIVERSAL MOUNT 100A MAX,DUAL 10/10 20A GMT,STUD/SCREW,FRONT CVR,UNIVERSAL VDC,BAY ALARM,2RU,UNIVERSAL MOUNT,TFA 100A MAX,DUAL 15/15 20A GMT,STUD/SCREW,R CVR,UNIVERSAL VDC,BAY ALARM,1RU,UNIVERSAL MOUNT 100A MAX,DUAL 20/20 20A GMT,STUD/SCREW,R CVR,UNIVERSAL VDC,BAY ALARM,1 RU,23" MOUNT ONLY HPGMT10 GMT05FA 5

6 Standard Part Description FUSE PNL,DBL,10,COMP,BLK FUSE PNL,DBL,10,COMP,BLK,FLT CB PANEL:30A,12 FEED,TFA,TELLABS,ROHS TRAD FP 20/20GMT,BAR/BAR,FLSF,AUX ALM,CPR HPGMT02R 0HPGMT03R 0HPGMT05NR 0HPGMT05R 20HPGMT05BNR 20HPGMT05FR 20HPGMT05R 20HPGMT12R-75RC 60GMT20 GMT10-BLK HPGMT10-BLK HPGMT10FA-1RU HPGMT10RC HPGMT15RC HPGMT20RC HPGMT20S HI PWR FP 20/20 GMT,STUD /SCREW,R CVR CP HI PWR FP 15/15 GMT,STUD /SCREW,R CVR CP HI PWR FP 10/10 GMT,STUD /SCREW,FILTER, 19",R CVR HI PWR FP 10/10 GMT,STUD /SCREW,R CVR CP HI PWR FP 10/10 20A GMT, STUD/SCREW,BAY ALM,FILTR HI PWR FP 10/10 20A GMT, STUD/SCREW,FAILSAFE,R CV HI PWR FP 10/10 20A GMT, STUD/SCREW,R CVR HI PWR FP 10/10 20A GMT, FFA, STUD/SCREW,FCVR 7.5",ROHS GMT FUSE PANEL:DUAL,60A,20/20 GMT,ALARM,+\-24-48Vdc 60A MAX,DUAL 10/10 20A GMT,SCREW CLAMP,R CVR,UNIVERSAL VDC,BAY ALARM, 1 RU,UNIVERSAL MOUNT, BLACK 100A MAX,DUAL 10/10 20A GMT,STUD/SCREW,R CVR,UNIVERSAL VDC,BAY ALARM,1 RU,UNIVERSAL MOUNT, BLACK 100A MAX,DUAL 10/10 20A GMT,STUD/SCREW,FRONT CVR,UNIVERSAL VDC,BAY ALARM,1RU,UNIVERSAL MOUNT,TFA 100A MAX,DUAL 10/10 20A GMT,STUD/SCREW,R CVR,UNIVERSAL VDC,BAY ALARM,1 RU,UNIVERSAL MOUNT,ROHS 100A MAX,DUAL 15/15 20A GMT,STUD/SCREW,R CVR,UNIVERSAL VDC,BAY ALARM,1RU,UNIVERSAL MOUNT,ROHS 100A MAX,DUAL 20/20 20A GMT,STUD/SCREW,R CVR,UNIVERSAL VDC,BAY ALARM,1 RU,23" MOUNT ONLY,ROHS 100A MAX,SINGLE 20 20A GMT,STUD/SCREW,R CVR,UNIVERSAL VDC,BAY ALARM,1 RU,UNIVERSAL MOUNT HPGMT05R 6

7 GMT Fuse Panel Matrix Part Number Input Rating per Bus Max. Fuse Size VDC Feed Fuses per Bus RU Mounting Specialty 60GMT10 60A 15A ±24/-48 Dual /23 GMT05FA 50A 15A ±24/-48 Dual /23 Total Front Access/Gray GMT10 60A 20A ±24/-48 Dual /23 Bay Alarms HPGMT10 100A 20A ±24/-48 Dual /23 Bay Alarms HPGMT10FA 100A 20A ±24/-48 Dual /23 Total Front Access HPGMT15 100A 20A ±24/-48 Dual /23 Bay Alarms HPGMT20 100A 20A ±24/-48 Dual Bay Alarms A 15A -48 Dual /23 Black A 15A -48 Dual / A 15A -48 Dual / A 10A -24/-48 Dual /23 0HPGMT02R 100A 15A -48 Dual HPGMT03R 100A 15A -48 Dual /23 0HPGMT05NR 75A 15A -48 Dual /23 0HPGMT05R 100A 15A -48 Dual /23 20HPGMT05BNR 75A 20A -48 Dual /23 Noise Filtering/Black Load Sharing/Black Load Sharing/Gray Noise Filtering Bay Alarms/Noise Filtering 20HPGMT05FR 75A 20A -48 Dual /23 Load Sharing 20HPGMT05R 100A 20A -48 Dual /23 20HPGMT12R- 75RC 100A 20A -48 Dual /23 60GMT20 60A 15A ±24/-48 Dual /23 GMT10-BLK 60A 20A ±24/-48 Dual /23 Black HPGMT10-BLK 100A 20A ±24/-48 Dual /23 Bay Alarms/Black 7

8 Part Number Input Rating per Bus Max. Fuse Size VDC Feed Fuses per Bus RU Mounting Specialty HPGMT10FA-1RU 100A 20A ±24/-48 Dual HPGMT10RC 100A 20A ±24/-48 Dual /23 HPGMT15RC 100A 20A ±24/-48 Dual /23 HPGMT20RC 100A 20A ±24/-48 Dual Bay Alarms/Total Front Access Bay Alarms/RoHS 6/6 Bay Alarms/RoHS 6/6 Bay Alarms/RoHS 6/6 HPGMT20S 100A 20A ±24/-48 Single /23 Bay Alarms 8

9 2. KLM Fuse Panels Strategic Part Description FUSE PNL:DUAL,4/4 KLM/GMT,100A,-48/-24/ Standard Part Description N FUSE PNL:DUAL,100A,KLM,-48ALRM,NEBS COMPLIANT H FUSE PNL:DUAL,4/4 KLM/GMT,150A,-48/-24/ RC FUSE PNL:DUAL,4/4 KLM/GMT,100A,-48/-24/+24,ROHS FUSE PNL:100A,5X5,KLM,COMP,WHT,NO GMT FUSE PNL:LOAD SHR,100A,KLM/GMT,-48V FUSE PNL:DUAL KLM/GMT,200A,-48 ALRM RC FUSE PNL:DUAL KLM/GMT,200A,-48 ALRM,ROHS 6/6 KLM Fuse Panel Matrix Part Number Input Rating per Bus A N H RC 100A 150A 100A Max. Fuse Size 30A KLM 30A KLM 10A GMT 30A KLM 30A KLM VDC 9 Feed Fuses per Bus RU Mounting ±24/-48 Dual 4/ /23-48 Dual 4/ /23-48 Dual 4/ /23 Specialty ±24/-48 Dual 4/ /23 RoHS 6/ A 30A KLM ±24/-48 Dual / A A RC 200A 30A KLM 30A KLM 30A KLM ±24/-48 Dual 4/ /23 Load Sharing ±24/-48 Dual 8/ /23 ±24/-48 Dual 8/ /23 RoHS 6/6

10 3. TPA Fuse Panels Strategic Part Description FUSE PNL:DUAL,4/5,TPA/GMT,200A,-48/-24/+24,WHT,1RU J FUSE PNL:DUAL,4/5,TPA/GMT,200A,20A GMT,GRAY DUAL FEED 350A, 8/10 TPA/GMT FUSE ALARM PANEL,+/-24-48VDC FUSE PNL:DUAL 100,4/4,TPA/GMT,-48,WHT,1RU Standard Part Description G FU, PANEL DL 4/5, 200A -48/-24/+24, 1RU,DUAL ALARM L DUAL 200A 4/5 TPA/GMT,-48/-24/+24VDC,25" DEPTH,1RU,WHT,ROHS LR DUAL 200A 4/5 TPA/GMT,-48/-24/+24VDC,25" DEPTH,1RU,W/SIDE RAILS LRC DUAL 200A 4/5 TPA/GMT,-48/-24/+24VDC,25" DEPTH,1RU,WHT,ROHS 6/ RC FUSE PNL:DUAL,4/5,TPA/GMT,200A,-48/-24/+24,WHT,1RU,ROHS 6/ FUSE PNL:DUAL, 4/20, TPA/GMT, 260A, -48/-24/+24, WHT, 2RU FUSE PNL:DUAL,4/5,TPA/GMT,200A,-48/-24/+24,BAY ALM,WHT,1RU H FUSE PNL:DUAL 150,4/4,TPA/GMT,-48,WHT,1RU HRC FUSE PNL:DUAL 150,4/4,TPA/GMT,-48,WHT,1RU,ROHS 6/ FUSE PNL:QUAD 100,4/4,TPA/GMT,-48,WHT,1RU H FUSE PNL:QUAD 130,4/4,TPA/GMT,-48,WHT,1RU RC FUSE PNL:QUAD 100,4/4,TPA/GMT,-48,WHT,1RU,ROHS 6/ (Front and rear view) 10

11 TPA Fuse Panel Matrix Part Number Input Rating per Bus A J 200A* A A * 200A maximum; 160A continuous G L LR LRC RC 200A 200A 200A 200A 200A A A H HRC 150A 150A A H RC 130A 100A Max. Fuse Size 20A GMT VDC Feed Fuses per Bus RU Mounting ±24/-48 Dual 4/ /23 ±24/-48 Dual 4/ /23 ±24/-48 Dual 8/ /23-48 Dual 4/ /23 Specialty Independent 20A GMT ±24/-48 Dual 4/ /23 A/B Power & Fuse Alarms 20A GMT ±24/-48 Dual 4/ /23 25 depth 25 20A GMT ±24/-48 Dual 4/ /23 Depth/Includes Mounting Rails 25 20A GMT ±24/-48 Dual 4/ /23 Depth/RoHS 6/6 ±24/-48 Dual 4/ /23 RoHS 6/6 ±24/-48 Dual 4/ /23 ±24/-48 Dual 4/ /23 Bay Alarms -48 Dual 4/ /23-48 Dual 4/ /23 RoHS 6/6-48 Quad 2/ /23 Quad Feed -48 Quad 2/ /23 Quad Feed -48 Quad 2/ /23 Quad Feed/RoHS 6/6 11

12 4. Circuit Breaker Panels All circuit breaker panels (except the T009-5xxxxxxxxxx family) will also support TFD holders for TPS or TLS fuses. Strategic Part Description FUSE PNL,DBL,6,COMP,REAR OUTPT,WHT,HC FUSE/BRKR 350CB06 600CB08 600CB10-CL HIGH CURRENT PANEL:DUAL, 350A, 6/5 CB(TFD)/GMT, Alarm, +24/-24/-48Vdc LOAD CENTER: DUAL, 600A, 8/5 CB/GMT, ALARM, +\-24-48VDC LOAD CENTER FRAME: 600CB10-C W/ 1-POLE LOAD STRAPS Standard Part Description RC FUSE PNL,DBL,6,COMP,REAR OUTPT,WHT,HC FUSE/BRKR,ROHS 6/ TFD FUSE PANEL:DUAL, 4/10, TFD/GMT, 350A, -48V 23" BLK, 2RU 350CB06RC DUAL, 350A, 6/5 CB(TFD)/GMT, ALARM, VDC, ROHS 600CB10 DUAL, 600A, 10 CB (TPC/TFD), ALARM, +/-24-48VDC 600CB10-C DUAL, 600A, 10 CB/TFD, HORIZ INPUT, COVER 600CB10-CLRC 600CB10-C W/ 1-POLE LOAD STRAPS,ROHS 600CB10-CRC DUAL, 600A,10 CB/TFD,HORIZ INPUT,COVER,ROHS 600CB10-CXL DUAL, 600A, 10 CB (TPC/TFD), ALARM, +/-24-48VD 600CB10-VL LOAD CENTER FRAME: 600CB10 W/ 1-POLE LOAD STRAPS 600CB10-XL LOAD CENTER FRAME: DUAL, 600A, 10 CB (TPC/TFD), ALARM, +/-24-48VD 600CB12 DUAL FEED 600A, 12CB, ALARM PANEL, +/-24-48VDC, CB12-C DUAL-FEED 600A 12 CB/TFD HORIZ INPUT +/-24/-48 VDC, 23" 600CB12-CL 600CB12-C W/1-POLE LOAD STRAPS +/-24/-48 VDC, 23" 600CB12-VL 600CB12 W/1-POLE LOAD STRAPS +/-24/-48 VDC, 23" T009-5xx0xxxxxxx* DUAL-FEED CB PNL,7/7 * See configuration information below circuit breaker panel product matrix 12

13 Circuit Breaker Panel Matrix Part Number Input Rating per Bus Max. Fuse Size VDC 13 Feed Fuses per Bus RU Mounting A 100A ±24/-48 Dual /23 350CB06 350A* 600CB08 600A See below 100A ±24/-48 Dual 6/ /23 Specialty ±24/-48 Dual 8/ /23 Bay Alarms 600CB10-CL 600A See below ±24/-48 Dual 10/ /23 Horizontal Inputs, Load Straps Included RC 200A 100A ±24/-48 Dual /23 RoHS 6/ TFD 350CB06RC 350A* 350A 100A ±24/-48 Dual 4/ See below ±24/-48 Dual 6/ /23 RoHS 6/6 600CB10 600A See below ±24/-48 Dual 10/ /23 600CB10-C 600A See below ±24/-48 Dual 10/ /23 600CB10-CLRC 600A See below ±24/-48 Dual 10/ /23 600CB10-CRC 600A See below ±24/-48 Dual 10/ /23 600CB10-CXL 600A See below ±24/-48 Dual 10/ /23 600CB10-VL 600A See below ±24/-48 Dual 10/ /23 600CB10-XL 600A See below ±24/-48 Dual 10/ /23 600CB12 600A See below ±24/-48 Dual 12/ CB12-C 600A See below ±24/-48 Dual 12/ Vertical Inputs, No Load Straps Included Horizontal Inputs, No Load Straps Included Horizontal Inputs, Load Straps Included/ RoHS 6/6 Horizontal Inputs, No Load Straps Included/ RoHS 6/6 15 Depth, Horizontal Inputs, No Load Straps Included Vertical Inputs, Load Straps Included 15 Depth, Vertical Inputs, No Load Straps Included Vertical Inputs, No Load Straps Included Horizontal Inputs, No Load Straps Included

14 Part Number Input Rating per Bus Max. Fuse Size VDC Feed Fuses per Bus RU Mounting 600CB12-CL 600A See below ±24/-48 Dual 12/ CB12-VL 600A See below ±24/-48 Dual 12/ T009-5xx0xxxxxxx* 40A or 100A 20A ±24/-48 Dual 7/ /23 Specialty Horizontal Inputs, Load Straps Included Vertical Inputs, Load Straps Included NOTE: All circuit breaker panels (except the T009-5x family) can support TFD fuse holders for TPS/TLS fuses. Maximum fuse sizes are: TPS up to 70A; TLS up to 125A. Single pole breaker maximum is 100A. All panels can support these maximums UNLESS noted above (example, only allows a maximum of 100A so a 125A TLS fuse could not be used). The 600CB08 and all 600CB1x panels will also support TPC fuses. T009-5xx0xxxxxxx Family Configuration Guide T009-5 X X 0 X X X X X X X Breaker positions per side Panel Color/Breaker Orientation 0 = Black enclosure/standard Breaker Installation with Off (O) at Top 3 = White Enclosure/Breakers Installed with On (I) at Top Inputs ( of Connector & Input Circuit Breaker) 0 = Screw-Tight Horizontal Inputs with 50A Thermal Input Breakers (40A inputs) 1 = Compression Inputs with 50A Thermal Input Breakers (40A inputs) 3 = Compression Inputs Without Input Breakers (100A max./side) Circuit breaker values are denoted in part numbers as follows: 0 = Blank 1 = 1A 3 = 3A 5 = 5A A = 10A F = 15A K = 20A 14

15 5. Demarcation Panels Strategic Part Description LINES 100AMP EA,COMP,ALM,CKT BKR Standard Part Description QUAD,100A,4 TPC/TFD,ALARM,+\-24-48VDC B QUAD, 125A, CB/TFD, PWR/FUSE ALARM B-TFD QUAD, 125A, 4 TFD, PWR/FUSE ALARM RC QUAD,100A,4 TPC/TFD,ALARM, VDC,ROHS 6/6 125DM08 EIGHT,125A,TFD/CB, ALARM, +\-24-48Vdc 125DM08-BLK EIGHT,125A,TFD/CB, ALARM, VDC, BLACK 125DM08-BLKRC EIGHT,125A,TFD/CB, ALARM, VDC, BLACK 125DM08-GMT SIX 125A TFD,DUAL 5/5 20A GMT 125DM08-TFD EIGHT,125A,TFD INSTALLED,ALARM,+\-24-48Vdc 125DM08-GMT 15

16 Demarcation Panel Matrix Part Number Input Rating per Bus Max. Fuse Size VDC Feed Fuses per Bus RU Mounting A 100A ±24/-48 Quad /23 Specialty Circuit Breakers only A 100A ±24/-48 Quad / B* 125A 100A CB 125A Fuse ±24/-48 Quad /23 Supports TPC, TPS/TLS Fuses B-TFD 125A 125A Fuse ±24/-48 Quad /23 TFD Holders Pre-installed RC 100A 100A ±24/-48 Quad /23 Supports TPC, TPS/TLS Fuses/RoHS 6/6 125DM08* 125A** 100A CB 125A Fuse ±24/-48 Eight /23 125DM08-BLK* 125A** 100A CB 125A Fuse ±24/-48 Eight /23 Black 125DM08-BLKRC* 125A** 100A CB 125A Fuse ±24/-48 Eight /23 Black/ RoHS 6/6 125DM08-GMT* 125A** 100A CB 125A TLS 20A GMT ±24/-48 Eight See note below 2 19 /23 125DM08-TFD* 125A** * Panels support circuit breakers or TFD holders for TPS/TLS fuses. ** 800A continuous total load for panel. 100A CB 125A Fuse ±24/-48 Eight 2 19 /23 TFD Holders Pre-installed NOTE: 125DM08-GMT is a hybrid demarcation low current fuse panel. It offers six demarcation inputs and dual feeds for 5x5 GMT output positions (see photo on page 14). 16

17 Appendix i. GMT Fuses GMT Fuse Part Number Designation Pin Part Number (color) 18/100A (yellow) 1/4A (violet) 1/2A (red) 3/4A (brown) 1A (gray) 1-1/3A (white) 1-1/2A (yellow/white) 2A (orange) 2-1/2A (orange/white) 3A (blue) 3-1/2A (blue/white) 4A (brown/white) 5A (green) 7-1/2A (black/white) 10A (red/white) 12A (yellow/green) 15A (blue/red) 20A without Safety Cover RC (green/white) 20A with Safety Cover (green/white) Dummy fuse GMT fuse safety cover ii. KLM and TPA Fuses KLM Fuse Part Number TPA Fuse Part Number 1A A A A A A A A A A A A A A A A Dummy KLM fuse Replacement TPA holder

18 iii. TPS and TLS Fuses TPS Fuse Part Number TLS Fuse Part Number 3A A A A A A A A A A A A TPS/TLS Fuse Holder A A A A iv. Asymmetrical Breakers a. (600CBxx family, nrg600bt08-m, nrgbdfb family) Standard Trip Circuit Breakers Item Description Part Number Item Description Part Number Single-Pole 1A Single-Pole 60A A A A A A A A A A Double-Pole 125A A A A A A Triple-Pole 200A A A A A CBXX faceplate 600CBXX- CBK nrgxx faceplate NOTE: Panels ship with faceplates pre-installed. Order faceplate only if lost or broken. 18

19 b. ( , 350CB06, family, 125DM08 family) Standard Trip Circuit Breakers with Faceplates Single-Pole Part Number Single-Pole Part Number 1A A A A A A A A A A A A A A A A c. ( x family) Standard Trip Circuit Breakers with Faceplates Single-Pole Part Number Single-Pole Part Number 1A A A A A A A A A A A A A A A A vii. Symmetrical Breakers (nrg600bt10-x and nrg600bt20s-x only) Standard Trip Circuit Breakers Item Description Part Item Description Part Number Number Single-Pole 5A Single-Pole 80A A A A A A Faceplate A Double-Pole 125A A A A A A Triple-Pole 200A A A A A NOTE: Panels ship with faceplates pre-installed. Order faceplate only if lost or broken. 19

20 viii. Instantaneous Trip Circuit Breakers ( , 350CB06, family, 125DM08 family) Single-Pole Part Number Single-Pole Part Number 20A A A A A A A A A A Faceplate (required) NOTE: Panels do not ship with faceplates. If using Instantaneous Trip Breakers, faceplates must be ordered. ix. Mid-Trip Circuit Breakers (600CBxx family) Single-Pole Part Number Single-Pole Part Number 2.5A A A A A A A A A A A A A A Faceplate (required) 600CBXX-CBK NOTE: Panels ship with faceplates pre-installed. Order faceplate only if lost or broken. 20

NetSure 802 SERIES DC POWER SYSTEM

NetSure 802 SERIES DC POWER SYSTEM NetSure 802 SERIES DC POWER SYSTEM Ordering Guide DRAFT NETSURE 802 SERIES DC POWER SYSTEM ORDERING GUIDE DRAFT Description The modular NetSure 802 power system is made up of an assortment of bays that

More information

9926 Series Branch Rated Circuit Breakers AC Version

9926 Series Branch Rated Circuit Breakers AC Version Branch Rated AC Version Hydraulic Magnetic Single pole and double pole versions 20/240 VAC, 50/60 Hz Up to 25A Just 3 mm wide Mounts on 35mm DIN-rail UL 489 listed, CSA C22.2 No. 5-02, CE VDE Ordering

More information

Power & Communication Cables

Power & Communication Cables Power & Communication Cables CBLSM-M & CBLSM-X series is the main power and communications cable consisting of a 7W main motor connector split out to a pre-wired RS- DB- connector to plug directly into

More information

DC POWER OVERVIEW BROCHURE Powerful Solutions for Critical Data and Telecom Applications

DC POWER OVERVIEW BROCHURE Powerful Solutions for Critical Data and Telecom Applications DC POWER OVERVIEW BROCHURE Powerful Solutions for Critical Data and Telecom Applications DC POWER OVERVIEW BROCHURE NETSURE APPLICATIONS yradio Base Station / Microwave Site ywireless & Wireline Access

More information

Connecting a Cisco Reader Module

Connecting a Cisco Reader Module CHAPTER 3 Overview The optional Cisco Reader Module (Figure 3-1) is similar to the Cisco Physical Access Gateway, providing the same ports for Weigand readers and other input and output devices. The Cisco

More information

Miniature Circuit Breakers and Supplementary Protectors. Contents

Miniature Circuit Breakers and Supplementary Protectors. Contents . Optimum and Efficient Protection for Every Application Product Overview Features Optimum product quality, tested reliability and safety stand for best protection of personnel, installations and plant.

More information

Infinity P2 Power System

Infinity P2 Power System P r o d u c t O v e r v i e w Infinity P2 Power System Dual Voltage, Rack Mounted Power System Configurations to 2000 Amps Dual Voltage power system Primary voltage can be positive or negative 48 and 80

More information

Introduction Circuit Protection

Introduction Circuit Protection Introduction Circuit Protection Weidmuller s DIN-rail mounted circuit breakers are available for use in applications where circuit protection must be able to distinguish between circuit overloads and short

More information

ULTRA-COMPACT 48V, 24V and 12V INTEGRATED DC POWER SYSTEMS

ULTRA-COMPACT 48V, 24V and 12V INTEGRATED DC POWER SYSTEMS ULTRA-COMPACT 48V, 4V and 1V INTEGRATED DC POWER SYSTEMS RU 1 DISTRIBUTION & CONTROLLER SECTION RECTIFIER SECTION LVD7//EEC KEY FEATURES Compact, RU High Fully Integrated System Hot-Swap Rectifier Modules

More information

UL 489 DIN rail branch circuit breakers

UL 489 DIN rail branch circuit breakers UL 9 DI rail branch circuit breakers FAZ-A circuit breakers Product Overview UL 9 DI rail branch circuit breakers FAZ-A circuit breakers PRODUCT OVERVIEW Optimum and efficient protection Optimum product

More information

QuickSpecs HP BladeSystem Breaker Panel

QuickSpecs HP BladeSystem Breaker Panel Overview The HP BladeSystem Breaker Panel is a dual input panel, where each input is rated for 240Amp, -36VDC to -72VDC. There are seven breakers on each input of the panel; where the first three are pre-configured

More information

VM VM

VM VM 2018 VM-5200-16 VM-5200-32 Operator s Manual The Daugherty Companies, Inc. P.O. Box 306 Warren, IN 46792 Ph. 260-375-2415 - Fax 260-375-3800 www.ag-electronics.com Rev 0418.1 NOTES: 2 Introduction Rev

More information

DMX Downlight Driver. LDD-DMX User Manual

DMX Downlight Driver. LDD-DMX User Manual DMX Downlight Driver LDD-DMX 2016 Digilin Australia. Document Rev : 5. 2-4 Nov ember 2016 Product spe cifications are subject to change without no tice. Table Of Contents Safety Notes... 2 Introduction...

More information

FMP VDC RECTIFIER 42 Amps 2000 Watts

FMP VDC RECTIFIER 42 Amps 2000 Watts FMP20.48 48VDC RECTIFIER 42 Amps 2000 Watts DESCRIPTION The FMP20.48 rectifier incorporates resonant technology to reduce component stresses and provide increased system reliability. The rectifier features

More information

SPECTRUM-2 CONSOLES. TEL: WEB: winsted.com

SPECTRUM-2 CONSOLES. TEL: WEB: winsted.com SPECTRUM-2 CONSOLES TEL: 800.447.2257 WEB: winsted.com EMAIL: info@winsted.com PRODUCT FEATURES AND HIGHLIGHTS Laminate with Safeguard Work Surface Spectrum 2 comes standard with our durable laminated

More information

Ordering Guide Compact Power Systems

Ordering Guide Compact Power Systems Ordering Guide Compact Power Systems V-Series Family 2052286 R1 Information in this document is subject to change without notice and does not represent a commitment on the part of Eltek Valere. No part

More information

E-Series General Specifications

E-Series General Specifications -Series General Specifications Ideally suited for higher amperage applications. Available with front and back mounting, screw terminals, stud terminals and heavy duty box wire connectors for solid wire

More information

8000 Series: Installation Supplement R2-1-12

8000 Series: Installation Supplement R2-1-12 8000 Series: Installation Supplement R2-1-12 Smartscan Incorporated, 33083 Eight Mile Road, Livonia MI 48152 Tel: (248) 477-2900 Fax: (248) 477-7453 Web: www.smartscaninc.com SMARTSCAN INCORPORATED Livonia,

More information

Parallel connection / operations and current share application note

Parallel connection / operations and current share application note Parallel connection / operations and current share application note Overview This document will examine method for active load sharing, basic criteria and performances of such a function on Glary UH and

More information

THIS PAGE LEFT BLANK

THIS PAGE LEFT BLANK SOUND LEVEL LIMITER THIS PAGE LEFT BLANK IMPORTANT Installer and Users please note: These instructions should be read carefully and left with the user of the product for future reference. The must be installed

More information

How do I... If you manage a datacenter, we have a solution for you.

How do I... If you manage a datacenter, we have a solution for you. If you manage a datacenter, we have a solution for you. How do I... Distribute power to all the equipment in the cabinet? Reboot remote servers and network devices? Know when the cabinet temperature is

More information

Safety. Features 1 ID: Make all the connections before you plug in the main power. DMX512 Controllable and RDM Configurable

Safety. Features 1 ID: Make all the connections before you plug in the main power. DMX512 Controllable and RDM Configurable Features DMX512 Controllable and RDM Configurable Designed for driving LED strips through 6 high power 12 and 24 Volts output units available Easy addressing interface (physical switches and RDM) Isolated

More information

CJ series Ergonomic multifunction joysticks

CJ series Ergonomic multifunction joysticks an APEM Group Company CJ series The CJ Series joystick features an ergonomic multifunction handle purposely designed for safety critical hand-operated applications. Available as a one or two axes joystick,

More information

Cisco Prisma II Platform

Cisco Prisma II Platform Cisco Prisma II Platform In optical transmission systems, the network platform forms the foundation of the product family. The Cisco Prisma II platform provides network operators with the unique features

More information

Saab TransponderTech. INSTALLATION GUIDE J4N Junction Box for R4 Navigation System

Saab TransponderTech. INSTALLATION GUIDE J4N Junction Box for R4 Navigation System Saab TransponderTech INSTALLATION GUIDE J4N Junction Box for R4 Navigation System Page i i Copyright The entire contents of this manual and its appendices, including any future updates and modifications,

More information

Modular plugs, accessories and tooling

Modular plugs, accessories and tooling Modular plugs, accessories and tooling Introducing the new Cat 6A/6 modular plugs, slim-line boots and color clips CommScope modular plug portfolio CommScope offers a vast portfolio of Modular Plugs for

More information

Overview. Features CHAPTER

Overview. Features CHAPTER CHAPTER 2 This chapter provides these topics that describe the Catalyst 2955 switch, hereafter referred to as the switch. Features, page 2-1 Front-Panel Description, page 2-3 Rear-Panel Description, page

More information

FMPe30.48G 48VDC RECTIFIER 60 Amps 2900 Watts

FMPe30.48G 48VDC RECTIFIER 60 Amps 2900 Watts FMPe30.48G 48VDC RECTIFIER 60 Amps 2900 Watts DESCRIPTION The FMPe30.48G rectifier incorporates resonant technology to reduce component stresses, providing increased system reliability and a best-in-class

More information

A-100G6 - Basic frame assembly diagram

A-100G6 - Basic frame assembly diagram doepfer System A - 100 Rack system A-100 G A-100G6 - Basic frame assembly diagram Parts: 1 Rail with lip, and with tapped hole strip inserted (with M3 threads). 2 Rail with lip, with three M3 hexagon nuts

More information

Meter Centraliser Alarm Centraliser Unit LM50-TCP (Code M31521) INSTRUCTION MANUAL (M A)

Meter Centraliser Alarm Centraliser Unit LM50-TCP (Code M31521) INSTRUCTION MANUAL (M A) Meter Centraliser Alarm Centraliser Unit LM50-TCP (Code M31521) INSTRUCTION MANUAL (M9813380120-A) 1.- BASIC INSTRUCTIONS 1.1.- Checks on receipt. This manual assists in the installation and handling of

More information

Installation Manual. Integrated System. V-Series Power Family Doc. No , Issue 8 Published 11-Dec-09

Installation Manual. Integrated System. V-Series Power Family Doc. No , Issue 8 Published 11-Dec-09 Installation Manual Integrated System V-Series Power Family Doc. No. 2056560, Issue 8 Published 11-Dec-09 Information in this document is subject to change without notice and does not represent a commitment

More information

ASR 5500 Hardware Platform Overview

ASR 5500 Hardware Platform Overview This chapter describes the hardware components that comprise the ASR 5500 chassis. The ASR 5500 is designed to provide subscriber management services for high-capacity 4G wireless networks. Figure 1: The

More information

IELR Rail-Mount Series Magnetic Circuit Protectors

IELR Rail-Mount Series Magnetic Circuit Protectors IELR Rail-Mount IELR Rail-Mount Series Magnetic Circuit Protectors Introduction 92 Single Pole 93 Specifications 94 Operating Characteristics 95 Delay Curves 96 Approvals & Decision Tables 200 IELR Series

More information

Leviton Products Referenced in the Rockwell Automation ENCOMPASS Program

Leviton Products Referenced in the Rockwell Automation ENCOMPASS Program Leviton Products Referenced in the Rockwell Automation ENCOMPASS Program Power Solutions for Industrial Automation Surge Protection & Power Connection Surge Protection Leviton s network approach to facility-wide

More information

DMK 11A & 11A GPS Owners Manual

DMK 11A & 11A GPS Owners Manual DMK 11A & 11A GPS Owners Manual Table of Contents Section I Description of DMK 11A & 11A-GPS 1.1 Introduction 1.2 Background 1.3 Infrastructure Connection 1.4 Components 1.5 Input Protocols 1.6 Configuration

More information

Prisma II Platform. Optoelectronics

Prisma II Platform. Optoelectronics Optoelectronics Prisma II Platform Description In optical transmission systems, the network platform forms the foundation of the product family. The Prisma II platform provides network operators with the

More information

Cisco CRS 16-Slot Chassis Power Systems

Cisco CRS 16-Slot Chassis Power Systems This chapter includes the following sections: Power specifications are provided in Technical Specifications Power Systems Overview, on page 1 Power Component Information Common to the Two Types of Power

More information

User Manual. JS-ICON 624 PACK Portable Dimmer Pack. JOHNSON SYSTEMS INC. Spring

User Manual. JS-ICON 624 PACK Portable Dimmer Pack. JOHNSON SYSTEMS INC. Spring User Manual JS-ICON 624 PACK Portable Dimmer Pack JOHNSON SYSTEMS INC. Spring 2007 Table of Contents JS-ICON 624 DMX JS-ICON 624 CC 6-2.4kW Dimming Strip JS-ICON 624 ND 6-2.4kW Relay Strip Introduction...3

More information

CS-10H0A413H3 (Master) Key Features. CL-10H0A413H3 (Link)

CS-10H0A413H3 (Master) Key Features. CL-10H0A413H3 (Link) CS-10H0A413H3 (Master) CL-10H0A413H3 (Link) The Server Technology Smart PDU provides local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a per-phase basis while

More information

Alternative Energy. Application Guide. Series and Field of Use. LVD Series. LVD Series. DCDC 1000 Watt. DCDC Series. GMT Series DB5-MG.

Alternative Energy. Application Guide. Series and Field of Use. LVD Series. LVD Series. DCDC 1000 Watt. DCDC Series. GMT Series DB5-MG. Alternative Energy Series and Field of Use LVD Series Low-Voltage Disconnect (LVD) stops battery damage due to over discharge by disconnecting the battery at an adjustable voltage. DCDC Series Regulated

More information

4 Connection and interface

4 Connection and interface 4 Connection and interface EXPOSED SIGNALS! DANGER Hazardous voltage levels may be present if using an open frame power supply to power the product. Failure to follow these instructions will result in

More information

Telephony Multi-Taps. 9000T-TP Series

Telephony Multi-Taps. 9000T-TP Series 9000T-TP Series The 9000T-TP series 1 GHz twisted-pair power multi-tap taps off part of its input RF and AC, but lets the rest pass through. It divides the tapped-off signal and power into multiple outputs,

More information

Dual-Feed 80A Auto Low Voltage Disconnect Panel - 80LVD02

Dual-Feed 80A Auto Low Voltage Disconnect Panel - 80LVD02 Dual-Feed 80A Auto Low Voltage Disconnect Panel - 80LVD02 User Manual 1.1 Overview Telect s 80A, -48 Vdc Low-Voltage Disconnect (LVD) panel is a rack-mounted component with coil-operated contactors. These

More information

MAXIOM. Data Sheet. Lighting Relay Panel. Overview Leverage the Power of BAS Integration

MAXIOM. Data Sheet. Lighting Relay Panel. Overview Leverage the Power of BAS Integration Data Sheet Lighting Relay Panel Overview Leverage the Power of BAS Integration Exterior with Surface Mount Trim The Series UL Listed, Lighting Control Panel provides the capability to control high voltage

More information

Power Supply Options for Helium-Neon Lasers

Power Supply Options for Helium-Neon Lasers Power Supply Options for Helium-Neon Lasers www.lumentum.com Data Sheet All Lumentum helium-neon power supplies provide a highly regulated constant current output, allowing for excellent optical stability

More information

TABLE OF CONTENT. Ver1.01 Date : BRIEF INTRODUCTION NOTICE ACCERSSORYS HOW TO PLAY METER BOARD...

TABLE OF CONTENT. Ver1.01 Date : BRIEF INTRODUCTION NOTICE ACCERSSORYS HOW TO PLAY METER BOARD... TABLE OF CONTENT Ver1.01 Date :2011-4-8 1. BRIEF INTRODUCTION... 1 2. NOTICE... 1 2-1. SAFTTY INSTRUCTIONS... 1 2-2. OPERATION INSTRUCTION... 1 3. ACCERSSORYS... 1 4. HOW TO PLAY... 2 5. TECHNICAL PARAMETERS...

More information

Who Needs Remote Power Management for Power Distribution, Power Measurement and Power Control of 48 VDC Equipment?

Who Needs Remote Power Management for Power Distribution, Power Measurement and Power Control of 48 VDC Equipment? Who Needs Remote Power Management for Power Distribution, Power Measurement and Power Control of 48 VDC Equipment? A Network Power Management White Paper Who Needs Remote Power Management for Power Distribution,

More information

Conect 121 Upgrade. Copyright 2013 Conqueror Design and Engineering Ltd.

Conect 121 Upgrade. Copyright 2013 Conqueror Design and Engineering Ltd. All rights reserved. Any dispute about the use of this software and/or hardware or of these terms and conditions shall be resolved or arbitrated under English Law. Manuals and accompanying documentation

More information

Series AI25 TM. Encoders. Absolute Encoder With SSI Interface. Data Sheet. ACURO with SSI Interface DESCRIPTION

Series AI25 TM. Encoders. Absolute Encoder With SSI Interface. Data Sheet. ACURO with SSI Interface DESCRIPTION Data Sheet TM Absolute Encoder With SSI Interface TM DESCRIPTION The Dynapar brand ACURO Absolute Encoder offers a modern full-feature design equipped with SSI interface. The AcuroAI25 optical absolute

More information

S-Series DeltaV Controller Interface for PROVOX I/O

S-Series DeltaV Controller Interface for PROVOX I/O DeltaV Distributed Control System Product Data Sheet S-Series DeltaV Controller Interface for PROVOX I/O The S-Series DeltaV Controller Interface for PROVOX I/O. I Provides a fast and easy upgrade for

More information

This Datasheet is for the IC693MDL /24 Volt DC, 0.5A Positive Logic Output, 32 Point.

This Datasheet is for the IC693MDL /24 Volt DC, 0.5A Positive Logic Output, 32 Point. This Datasheet is for the IC693MDL753 12/24 Volt DC, 0.5A Positive Logic Output, 32 Point http://www.qualitrol.com/shop/p-14675-ic693mdl753.aspx Provides the wiring diagrams and installation guidelines

More information

Overvoltage Protection

Overvoltage Protection Overvoltage Protection Weidmuller has a complete line of overvoltage protection devices to effectively stop the harmful effects of electrical overvoltage and electrical noise. There is strong potential

More information

QuickSpecs. HPE Standard Series G2 Basic Power Distribution Units (PDU) Overview. Basic, reliable power distribution for your HPE IT solutions

QuickSpecs. HPE Standard Series G2 Basic Power Distribution Units (PDU) Overview. Basic, reliable power distribution for your HPE IT solutions Overview Basic, reliable power distribution for your HPE IT solutions G2 Basic PDUs are designed to work precisely with HPE Infrastructure and Compute solutions. Designed for use with HPE Standard, Advanced,

More information

OPTICAL HEADEND PLATFORM OTOHP-CH 3RU CHASSIS OTOHP-PS POWER SUPPLY MODULE OTOHP-BP BLANK PANEL INSTRUCTION MANUAL

OPTICAL HEADEND PLATFORM OTOHP-CH 3RU CHASSIS OTOHP-PS POWER SUPPLY MODULE OTOHP-BP BLANK PANEL INSTRUCTION MANUAL OPTICAL HEADEND PLATFORM OTOHP-CH 3RU CHASSIS OTOHP-PS POWER SUPPLY MODULE OTOHP-BP BLANK PANEL INSTRUCTION MANUAL Phone: (209) 586-1022 (800) 545-1022 Fax: (209) 586-1026 OTOHP-CH Rev. X1 E-Mail: salessupport@olsontech.com

More information

Copper. Patch Panels COPPER CONNECTIVITY. pg. 40. Clarity 10G Patch Panels. Clarity. Patch Panels. Special Application. Patch Panels.

Copper. Patch Panels COPPER CONNECTIVITY. pg. 40. Clarity 10G Patch Panels. Clarity. Patch Panels. Special Application. Patch Panels. HIGH PERFORMANCE STRUCTURED CABLING PRODUCTS AND SOLUTIONS COPPER CONNECTIVITY Copper Clarity Special Application Ortronics/Legrand continues to lead the industry in patch panel design by fully supporting

More information

Intel 4-Processor Server System S7000FC4UR Configuration Guide Intel Value and Enterprise Servers

Intel 4-Processor Server System S7000FC4UR Configuration Guide Intel Value and Enterprise Servers Intel 4-Processor Server System S7000FC4UR Configuration Guide Intel Value and Enterprise Servers Rev 1.7 A reference guide to assist customers in ordering components to configure S7000FC4UR 4-Processor

More information

IELR Series

IELR Series IELR Series Rail-Mount Magnetic Circuit Protectors Introduction Poles Specifications Operating Characteristics Delay Curves Approvals Decision Tables 6 62 63 64 65 69 70 IELR Series Rail-Mount Hydraulic

More information

EC07 EC63. Compatible actuators: ERL2 ESD2. How to order EC 07 B. Series. B Installation. method

EC07 EC63. Compatible actuators: ERL2 ESD2. How to order EC 07 B. Series. B Installation. method Controller EC07 EC63 Compatible actuators: ERL ESD Features Compact, light weight and thin (Body width 35mm) Can be set without manual Perfect installation compatibility with actuator PC software available

More information

7I44 MANUAL 8 CHANNEL RS-422 INTERFACE

7I44 MANUAL 8 CHANNEL RS-422 INTERFACE 7I44 MANUAL 8 CHANNEL RS-422 INTERFACE V1.1 This page intentionally almost blank Table of Contents GENERAL.......................................................... 1 DESCRIPTION.................................................

More information

Installing the IPS 4345 and IPS 4360

Installing the IPS 4345 and IPS 4360 CHAPTER 4 Installing the IPS 4345 and IPS 4360 Contents This chapter describes the Cisco IPS 4345 and the IPS 4360, and includes the following sections: Installation Notes and Caveats, page 4-1 Product

More information

Translink Controller Installation Manual V1.0

Translink Controller Installation Manual V1.0 Translink Controller Installation Manual V1.0 1 Contents 2 Warning... 3 3 Overview... 3 4 Packaging... 3 5 Physical Installation... 3 6 Wiring... 4 6.1 Power... 4 6.2 Ethernet... 4 6.3 C-Bus... 4 6.3.1

More information

CLS LDV-45. CLS Atmosphere LED-panel CLS LDV-45

CLS LDV-45. CLS Atmosphere LED-panel CLS LDV-45 INTRODUCTION The is a DMX controllable LED dimmer, which has a maximum of 4 regulated voltage DC outputs. Up to a maximum of 5A per channel at 2-24 Volts, with a total maximum current of 0A. Equipped with

More information

Quick Start Installation Guide

Quick Start Installation Guide apc/l Quick Start Installation Guide Version A2 Document Part Number UM-201 May 2010 OVERVIEW The apc/l is an intelligent access control and alarm monitoring control panel which serves as a basic building

More information

Substation Automation Products. Bay control REC670/650 Relion 670 and 650 series

Substation Automation Products. Bay control REC670/650 Relion 670 and 650 series Substation Automation Products Bay control REC670/650 Relion 670 and 650 series For optimized control and reliable operation of your switchyard The REC670 and REC650 Bay control IEDs (Intelligent Electronic

More information

Enhanced Performance, Versatility, High Availability, and Reliability at the Provider Edge

Enhanced Performance, Versatility, High Availability, and Reliability at the Provider Edge Enhanced Performance, Versatility, High Availability, and Reliability at the Provider Edge Cisco 7609-S Router The Cisco 7609-S Router is a high-performance router deployed at the network edge, where performance,

More information

Category 5e Solutions

Category 5e Solutions Introduction... 5.2 Cable... 5.3 Patch Panels... 5.4 Modules... 5.5 Patch Cords... 5.8 Mutos and Consolidation Points... 5.13 Outlets... 5.14 www.adckrone.com AUS 1800 801 298 NZ 0800 657 663 5.1 Introduction

More information

Option X4 Additional Operator Panel AOP-2 Description of option Functional description

Option X4 Additional Operator Panel AOP-2 Description of option Functional description MULTI-LINE 2 DESCRIPTION OF OPTIONS Option X4 Additional Operator Panel AOP-2 Description of option Functional description DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: +45 9614 9614 Fax: +45 9614 9615

More information

Panel Interface Connectors

Panel Interface Connectors PIC... 260-285 Accessories...286-293 259 (PIC) A panel interface connector (PIC) is a device that is mounted to the outside (exterior) of a panel that houses a PLC or computer. The PIC allows the user

More information

Contents Safety precautions Product components Optional accessories Names of each parts Product Dimension Cables and Connectors Power Connection

Contents Safety precautions Product components Optional accessories Names of each parts Product Dimension Cables and Connectors Power Connection Contents Safety precautions Product components Optional accessories Names of each parts Product Dimension Cables and Connectors Power Connection LAN Connection RS485 Connection Relay Connection Digital

More information

Products :: Circuit Protection :: Hydraulic/Magnetic Circuit Breakers

Products :: Circuit Protection :: Hydraulic/Magnetic Circuit Breakers Products :: Circuit Protection :: Hydraulic/Magnetic Circuit Breakers Hydraulic/Magnetic Circuit Breaker B-Series B-Series PDF elibrary The B-Series hydraulic/magnetic circuit breakers are compact and

More information

Data Sheet Miniature Circuit Breaker Comb Bus Bar UL 489 & UL 1077

Data Sheet Miniature Circuit Breaker Comb Bus Bar UL 489 & UL 1077 Data Sheet Miniature Circuit Breaker Comb Bus Bar 489 & na.noark-electric.com NOARK 489/1077 Features 489 Miniature Circuit Breakers Comb Bus Bar: Available for 1, 2 and 3 poles Available in 80 A and 100

More information

Power Supply Options for Helium-Neon Lasers

Power Supply Options for Helium-Neon Lasers Power Supply Options for Helium-Neon Lasers www.lumentum.com Data Sheet All Lumentum helium-neon power supplies provide a highly regulated constant current output, allowing for excellent optical stability

More information

BLU- CIF Interface Board

BLU- CIF Interface Board BLU- CIF Interface Board The BLU-CIF Interface Board simplifies the wiring of all of the BLU products to the BSS Audio London Series Digital Signal Processors. It allows for Cat5e wiring termination, as

More information

Luxline driver. LL-PCB-LUXlinedriver. Lux Lumen bvba Kernenergiestr. 53a 2610 Wilrijk. Luxline driver - page 1 T F

Luxline driver. LL-PCB-LUXlinedriver. Lux Lumen bvba Kernenergiestr. 53a 2610 Wilrijk. Luxline driver - page 1 T F Luxline driver LL-PCB-LUXlinedriver Lux Lumen bvba Kernenergiestr. 53a 2610 Wilrijk 10200 T +32 3 293 35 50 F +32 3 293 35 44 Luxline driver - page 1 Content PCB Layout Placement Connectors Supply Wago

More information

Introduction to Class 5 Connectivity

Introduction to Class 5 Connectivity Introduction to Class Connectivity APPENDIX SOFTWARE GEAR HEADS POWER SUPPLIES & SHUNTS IP MODELS & CONNECTIVITY PERIPHERALS CONNECTIVITY LINEAR SYSTEMS MOTOR SPECIFICATIONS OVERVIEW Power: Each SmartMotor

More information

Westell. Breaker Panel Technical Practice NPDRP1114

Westell. Breaker Panel Technical Practice NPDRP1114 030-000218 REV F 1114-03F June 29, 2017 Westell Breaker Panel Technical Practice NPDRP1114 FEATURES DIN rail panel accepts up to 6 DIN rail devices (one surge and 5 breakers) Specific configuration of

More information

Reference Manual EPM-PS1. PC/104-Plus Power Supply Module DOC. REV. 4/29/2009

Reference Manual EPM-PS1. PC/104-Plus Power Supply Module DOC. REV. 4/29/2009 Reference Manual DOC. REV. 4/29/2009 EPM-PS1 PC/104-Plus Power Supply Module WWW.VERSALOGIC.COM 12100 SW Tualatin Road Tualatin, OR 97062-7341 (503) 747-2261 Fax (971) 224-4708 Contents Copyright 2013

More information

Breaker Panel Technical Practice NPDRP1114

Breaker Panel Technical Practice NPDRP1114 030-000218 REV E 1114-03E January 30, 2013 Westell Breaker Panel Technical Practice NPDRP1114 FEATURES DIN rail panel accepts up to 6 DIN rail devices (one surge and 5 breakers) Specific configuration

More information

Extending Performance, Versatility, and Reliability at the Provider Edge

Extending Performance, Versatility, and Reliability at the Provider Edge Cisco 7613 Chassis Extending Performance, Versatility, and Reliability at the Provider Edge Cisco 7613 Router The Cisco 7613 Router is a high-performance router designed for deployment at the network edge

More information

Selection Guide. Control Circuit and Load Protection. Allen-Bradley 1489-M2C020

Selection Guide. Control Circuit and Load Protection. Allen-Bradley 1489-M2C020 Selection Guide Control Circuit and Load Protection Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United States and Canada, and certified as Miniature

More information

BLU- CIF2 Interface Board

BLU- CIF2 Interface Board BLU- CIF2 Interface Board The BLU-CIF2 Interface Board simplifies the wiring of all of the BLU products to two BSS Audio London Series Digital Signal Processors. It allows for Cat5e wiring termination,

More information

C-Series. Circuit Breaker

C-Series. Circuit Breaker C-Series Circuit Breaker The C-Series hydraulic/magnetic circuit breakers are ideal for applications that require higher amperage and voltage handling capability in a smaller package. They are available

More information

TrueNet TFP Series Rack Mount Fiber Panels

TrueNet TFP Series Rack Mount Fiber Panels TFP Series Rack Mount Fiber Panels The rack mount TrueNet Fiber Panel (TFP) is an integral part of the TrueNet Fiber product portfolio. The TFP fiber panels can be ordered in one, two and five rack unit

More information

POWERING TECHNOLOGY. Reliably powering your business. Solving your power needs. DC POWER SYSTEMS

POWERING TECHNOLOGY. Reliably powering your business. Solving your power needs. DC POWER SYSTEMS POWERING TECHNOLOGY Reliably powering your business. Solving your power needs. DC POWER SYSTEMS P O W E R I N G T E C H N O L O G Y UNIPOWER Systems today incorporates products from the former Power-One

More information

DECam PFC Power Distribution Chassis (Production Version)

DECam PFC Power Distribution Chassis (Production Version) DECam PFC Power Distribution Chassis (Production Version) Steven Chappa 04 October 2011 (Revised: 24 November 2011) General Description: The chassis described is used for delivering AC and DC power to

More information

This Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount.

This Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount. This Datasheet for the IC697CHS790 Rack, 9 Slots, Rear Mount. http://www.cimtecautomation.com/parts/p-14771-ic697chs790.aspx Provides the wiring diagrams and installation guidelines for this GE Series

More information

Note: the wiring of the dead-man buttons has been changed since October 2001.

Note: the wiring of the dead-man buttons has been changed since October 2001. UniOP epalm10 The epalm10 is a state-of-the-art handheld HMI device with a graphic display and a keypad. The rugged polyamide enclosure offers a high level of shock and environmental resistance making

More information

DL-HDM44A-H2 Quick Install Guide

DL-HDM44A-H2 Quick Install Guide DL-HDM44A-H2 Quick Install Guide This guide is for quick installation only. For complete owners manual go to www.libav.com or use a QR reader to access the manual via QR code below. Scan QR Code with your

More information

CS-12HDE444C8 (Master) Key Features. CL-12HDE444C8 (Link)

CS-12HDE444C8 (Master) Key Features. CL-12HDE444C8 (Link) CS-12HDE444C8 (Master) CL-12HDE444C8 (Link) The Server Technology Smart PDU provides local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a per-phase basis while

More information

RAK-STAR: CAT-5 star distribution unit

RAK-STAR: CAT-5 star distribution unit RAK-STAR: CAT-5 star distribution unit Rako Wired system can be connected by Loop in/loop out wiring scheme or by Home Run scheme. In Home Wiring scheme all Wall Plates and other devices can be wired back

More information

Enhanced Performance, Versatility, High Availability, and Reliability at the Provider Edge.

Enhanced Performance, Versatility, High Availability, and Reliability at the Provider Edge. Data Sheet Cisco 7606-S Router Enhanced Performance, Versatility, High Availability, and Reliability at the Provider Edge. The Cisco 7606-S Router is a compact, high-performance router designed in a 6-slot

More information

IT power distribution Power distribution units (PDU) Basic. Versions available:

IT power distribution Power distribution units (PDU) Basic. Versions available: IT PDU Basic 1 U With its IT PDU Basic 1 U, BACHMANN provides a huge choice of PDUs in a high-quality aluminium profile. With their extremely compact size of just 1 height unit, mm in depth and 1" in width,

More information

Junos WebApp Secure 5.0 Hardware Guide

Junos WebApp Secure 5.0 Hardware Guide Junos WebApp Secure 5.0 Hardware Guide Junos WebApp Secure 5.0 Hardware Guide This document contains a specification for the MWS1000 hardware appliance, as well as instructions for installation into a

More information

Publication version 2.2 November RS485 Slave Intercoms WIRING INFORMATION

Publication version 2.2 November RS485 Slave Intercoms WIRING INFORMATION Publication version 2.2 November 2002 RS485 Slave Intercoms WIRING INFORMATION About this document The purpose of this document is to provide a complete wiring description, of the selected JACQUES product.

More information

Operating Bulletin. Model BB3-232 and BB3-I-232 USB Multi-Drop Box. The Fastest Flow Controller Company in the World!

Operating Bulletin. Model BB3-232 and BB3-I-232 USB Multi-Drop Box. The Fastest Flow Controller Company in the World! Operating Bulletin Model BB3-232 and BB3-I-232 USB Multi-Drop Box The Fastest Flow Controller Company in the World! 1 10/16/2017 Rev.1 DOC-BB3232MAN 2 Introduction Alicat BB3-232 Multi-Drop Box Operating

More information

PERCENT OF RATED CURRENT

PERCENT OF RATED CURRENT A-D Series Time Delay Values PERCENT OF RATED CURRENT NOTES: UL489 C-Series Breakers available with Delay Curves 11, 12, 14, 16, 21, 22, 24, 26, 42, 44, 46. Delay Curves 11,12,14,16,21,22,24,26,42,44,46,52,54,56:

More information

BC-9000 Field Calibration Procedure CF1_FIELDCAL_BC9000 Revised 03/16/2013

BC-9000 Field Calibration Procedure CF1_FIELDCAL_BC9000 Revised 03/16/2013 BC-9000 Field Calibration Procedure CF1_FIELDCAL_BC9000 Revised 03/16/2013 INTRODUCTION: The BC-9000 Battery Charger will recharge12 and 24 volt lead-acid and nickel cadmium batteries. Battery charging

More information

Table of Contents 1 ABOUT THIS GUIDE CONTACT INFORMATION ANTENNA INSTALLATION... 4

Table of Contents 1 ABOUT THIS GUIDE CONTACT INFORMATION ANTENNA INSTALLATION... 4 Table of Contents 1 ABOUT THIS GUIDE... 3 1.1 CONTACT INFORMATION... 3 2 ANTENNA INSTALLATION... 4 2.1 GENERAL INFORMATION... 4 2.2 SPECIFIC MOUNTING EXAMPLES... 5 2.3 CONNECTOR MOISTURE PROTECTION...

More information

Artistic Licence. Rail-Switch II. User Guide. Rail-Switch II User Guide. Version 5-5

Artistic Licence. Rail-Switch II. User Guide. Rail-Switch II User Guide. Version 5-5 Artistic Licence Rail-Switch II User Guide Version 5-5 Please read these instructions before using the product. This product has been designed & manufactured for professional use only. It should only be

More information

ex-s1110-xt Gigabit Ethernet Extenders

ex-s1110-xt Gigabit Ethernet Extenders ex-s1110- Gigabit Ethernet Extenders perle.com/products/10-100-1000-industrial-ethernet-extender.shtml 10/100/1000 Industrial Temperature Copper Extender Extends 10/100/1000Base-T Ethernet up to 10,000

More information