35 Copper Spun Driers Kap Kit Two Way Heat Pump Driers Suitable for HFC, CFC and HCFC.

Size: px
Start display at page:

Download "35 Copper Spun Driers Kap Kit Two Way Heat Pump Driers Suitable for HFC, CFC and HCFC."

Transcription

1 Copper Spun Driers Suitable for HFC, CFC and HCFC. C440 MSCD-5-3 3/16 x 2.5mm C441 MSCD /16 x 2.5 C442 MSCD /4 x 2.5 C443 MSCD-20 1/4 x 2.5 C444 MSCD-30 1/4 x 2.5 C448 MSCD-20S 1/4 x 1/4 Kap Kit One piece Drier and Capillary enabling quick and easy replacement. Code Model Application C450 KK1L-25 LBP 0.15 kw C451 KK1H-25 HBP 0.15 C452 KK2L-25 LBP 0.37 kw C453 KK2H-25 HBP 0.37 Two Way Heat Pump Driers The Catch-All Heat Pump Driers internal construction allows reversible refrigerant flow while providing effective filtration and contaminant retention. External check valves are not required. C120 HPC-103F 3/8 flare C121 HPC-104F 1/2 C126 HPC -103S 3/8 solder C127 HPC -104S 1/2 35

2 Sporlan Driers Catch-All Filter Driers remove Moisture, Fine Particles and Acid. C460 C 032 1/4 flare C461 C 052 1/4 C462 C 082 1/4 C465 C 053 3/8 C466 C 083 3/8 C467 C 163 3/8 C468 C 303 3/8 C471 C 084 1/2 C472 C 164 1/2 C473 C 304 1/2 C476 C 165 5/8 C477 C 305 5/8 C480 C 032S 1/4 Solder C481 C 052S 1/4 C482 C 082S 1/4 C485 C 053S 3/8 C486 C 086S 3/8 C488 C 163S 3/8 C490 C 084S 1/2 C491 C 164S 1/2 Burnout Driers Eliminator Burnout driers type DAS are used in the suction line to clean up refrigeration and air conditioning systems after a compressor motor burn out. The solid core is composed of 70% activated alumina and 30% molecular sieves. The DAS drier absorbs both moisture and harmful acids thereby protecting the new compressor against premature failure. C050 DAS 083VV 3/8 flare C051 DAS 084VV 1/2 C052 DAS 164VV 1/2 C053 DAS 165VV 5/8 C055 DAS 083sVV 3/8 solder C056 DAS 084sVV 1/2 C059 DAS 164sVV 1/2 C060 DAS 165sVV 5/8 C063 DAS 305sVV 5/8 C064 DAS 306sVV 3/4 C065 DAS 307sVV 7/8 C069 DAS 417sVV 7/8 C070 DAS 419SVV 1-1/8 C072 DAS 609sVV 1-1/8 36 Sales Office:

3 Danfoss Driers Danfoss DCL driers are suitable for use with HFC s, HCFC s and CFC s. The drier has a solid core containing 80% 3A molecular sieves and 20% activated alumina for acid absorption and is therefore suited for service work. Flare connections - DCL C301 DCL 032 1/4 flare C302 DCL 052 1/4 C303 DCL 082 1/4 C304 DCL 162 1/4 C306 DCL 053 3/8 flare C307 DCL 083 3/8 C308 DCL 163 3/8 C309 DCL 303 3/8 C311 DCL 084 1/2 flare C312 DCL 164 1/2 C313 DCL 304 1/2 C315 DCL 165 5/8 flare C316 DCL 305 5/8 C318 DCL 306 3/4 flare Solder connections - DCL C320 DCL 032S 1/4 solder C321 DCL 052S 1/4 C325 DCL 053S 3/8 solder C326 DCL 083S 3/8 C327 DCL 163S 3/8 C330 DCL 084S 1/2 solder C331 DCL 164S 1/2 C332 DCL 304S 1/2 C334 DCL 165S 5/8 solder C335 DCL 305S 5/8 C336 DCL 306S 3/4 solder C337 DCL 307S 7/8 solder C338 DCL 607S 7/8 37

4 Danfoss Driers Danfoss DML driers are suitable for use with HFC s, HCFC s and CFC s. The drier has a solid core containing 100% 3A molecular sieves. Flare connections - DCL C251 DML 032 1/4 flare C252 DML 052 1/4 C253 DML 082 1/4 C254 DML 162 1/4 C256 DML 053 3/8 flare C257 DML 083 3/8 C258 DML 163 3/8 C259 DML 303 3/8 C261 DML 084 1/2 flare C262 DML 164 1/2 C263 DML 304 1/2 C265 DML 165 5/8 flare C266 DML 305 5/8 C267 DML 306 3/4 flare Solder connections - DML C270 DML 032S 1/4 solder C271 DML 052S 1/4 C274 DML 053S 3/8 solder C275 DML 083S 3/8 C276 DML 163S 3/8 C278 DML 084S 1/2 solder C279 DML 164S 1/2 C280 DML 304S 1/2 C282 DML 165S 5/8 solder C283 DML 305S 5/8 C285 DML 306S 3/4 solder C287 DML 307S 7/8 solder C288 DML 607S 7/8 38 Sales Office:

5 Drier Shells Drier Shells can be used in either the Liquid or Suction Line. For capacities please see overleaf. Drier shells are supplied WITHOUT Cores. Please order separately. Code Model No of Cores 5/8 Connections C600 DCR x 48 Core 7/8 Connections C602 DCR x 48 Core C603 DCR x /8 Connections C605 DCR x 48 Core C606 DCR x /8 Connections C609 DCR x 48 Core C610 DCR x 48 C611 DCR x /8 Connections C615 DCR x 48 Core C616 DCR x 48 C618 DCR x /8 Connections C621 DCR x 48 Core C622 DCR x 48 C623 DCR x 48 C624 DCR x 48 Drier Cores 48-DC Solid core consisting of 3A molecular sieves compatible with R22, R134a R404A and R507. Also compatible with most blends. Activated aluminium oxide for acid absorption. 48-DM Solid core with 100% 3A molecular sieves compatible with R134a, R404A and R407C. 48-DA Solid core with high acid absorption and standard water absorption. Compatible with R22, R134a, R404A and R F Strainer. For use in suction or liquid lines. Compatible with all fluorinated refrigerants. Code Model Style Danfoss C DN High Moisture Capacity C DU Extra High Moisture Capacity C DA Decontamination C F Strainer Alternative C H High Moisture Capacity C SC Decontamination C H High Moisture Capacity 39

6 40 Sales Office:

7 Drier Shell Capacities These capacities are based on normal refrigeration systems, for systems with long pipe runs or systems in adverse conditions use a larger drier Recommended Liquid Line Capacity in kw given in accordance with ARI evaporating temperature = -15ºC condensing temperature = +30ºC and pressure drop across the filter drier = 0.07 bar. Core Type 48DN Core Type 48-DU R404A R407C R404A R407C Model R22 R134a R507 R410 R134a R507 R410 DCR DCR DCR DCR DCR DCR DCR DCR DCR DCR DCR DCR DCR DCR DCR Suction Line Capacity in kw given in accordance with ARI evaporating temperature = +4.4ºC, condensing temperature = +32.2ºC and pressure drop across the filter drier = 0.21 bar R22, R407C, R410A R134a, R507 R404A Model -20ºC +4.4ºC -20ºC +4.4ºC -40ºC -20ºC +4.4ºC DCR DCR DCR DCR DCR DCR DCR DCR DCR DCR DCR DCR DCR DCR DCR

8 Danfoss Sight Glasses SGN sight glasses are fitted with an indicator, which changes colour to show the moisture content in the refrigerant. The sight glass will also indicate a lack of sub cooling or a shortage of refrigerant in the system. C350 SGN 6 1/4 flare C351 SGN 6MF 1/4 m x f C352 SGN 6S 1/4 solder C353 SGN10 3/8 flare C354 SGN10MF 3/8 m x f C355 SGN10S 3/8 solder C356 SGN12 1/2 flare C357 SGN12MF 1/2 m x f C358 SGN12S 1/2 solder C359 SGN16 5/8 flare C360 SGN16MF 5/8 m x f C361 SGN16S 5/8 solder C362 SGN19 3/4 flare C363 SGN19MF 3/4 m x f C364 SGN19S 3/4 solder C365 SGN22S 7/8 solder Sporlan Sight Glasses SA sight glasses are fitted with an indicator, which changes colour to show the moisture content in the refrigerant. The See-All indicator may turn brown if the system is circulating an excess amount of oil. The sight glass can remain in the system as the flow of Refrigerant will return the See-All to normal when the oil returns to the crankcase. C214 SA-17S 7/8 Solder C215 SA-19S 1-1/8 Solder C216 SA /8 Solder C217 SA /8 Solder C218 SA /8 Solder 42 Sales Office:

ELIMINATOR Hermetic burn-out filter drier Type DAS

ELIMINATOR Hermetic burn-out filter drier Type DAS Data sheet ELIMINATOR Hermetic burn-out filter drier DAS ELIMINATOR Hermetic burn-out filter driers type DAS are used in the suction line to clean up refrigeration and air conditioning systems after a

More information

AIR COOLED HEAT PUMPS WITH SCREW COMPRESSORS AND AXIAL FANS

AIR COOLED HEAT PUMPS WITH SCREW COMPRESSORS AND AXIAL FANS PAH 2802 T K AIR R-407C R-134a Series PAH... T K from 205 to 778 kw - 2 circuits The air cooled heat pumps of PAH.T series are designed for outdoor installation and are particularly suitable for industrial

More information

Electrically operated expansion valves, type ETS REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Electrically operated expansion valves, type ETS REFRIGERATION AND AIR CONDITIONING. Technical leaflet Electrically operated expansion valves, type ETS REFRIGERATION AND AIR CONDITIONING Technical leaflet Contents Page Introduction........................................................................................3

More information

LINE UP LINE UP (RT) ( RCUP75AUZ / 50Hz ) Products Series RCUP-AUZ

LINE UP LINE UP (RT) ( RCUP75AUZ / 50Hz ) Products Series RCUP-AUZ Hitachi screw chiller unit widely used for air conditioning and industrial purposes Newly released, equipped with a new screw compressor realizing drastic energy saving and great functionality ( RCUP75AUZ

More information

STANDARD MODELS MT 3/4 HP + LT 2.5 HP MT 1.0 HP + LT 2.5 HP. Other models available upon request

STANDARD MODELS MT 3/4 HP + LT 2.5 HP MT 1.0 HP + LT 2.5 HP. Other models available upon request PRODUCT DATA & SPECIFICATIONS Bulletin B40-BC-PDS Part # 1106712 PRODUCT SUPPORT web: b-rp.ca/bc email: multicompcu@b-rp.ca call: 1-844-893-3222 x524 scan: BC Combination Condensing Units Cooler/Freezer

More information

AIR COOLED CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS

AIR COOLED CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS RAH 913 K AIR R-407C R-134a Series RAH... from 307 to 1879 kw - from 1 to 4 circuits The air cooled chillers of RAH series are extremely compact units so to reduce the installation spaces and weights.

More information

glide glider kw R134a air cooled liquid chillers AND free cooling chillers FREE COOLING SHELL A C CLASS E C Energy Class RCGROUP SpA

glide glider kw R134a air cooled liquid chillers AND free cooling chillers FREE COOLING SHELL A C CLASS E C Energy Class RCGROUP SpA 99 glide air cooled liquid chillers ND free cooling chillers glider 178 1328 Energy Class More efficient + B C D E F G Less efficient R134a CLSS SHELL C E C FREE COOLING 100 air cooled liquid chiller and

More information

CHAPTER 3 WATERCOOLED & CONDENSERLESS LIQUID CHILLERS AND HEAT PUMPS FOR COMMERCIAL & INDUSTRIAL APPLICATION. REMOTE CONDENSERS

CHAPTER 3 WATERCOOLED & CONDENSERLESS LIQUID CHILLERS AND HEAT PUMPS FOR COMMERCIAL & INDUSTRIAL APPLICATION. REMOTE CONDENSERS CHAPTER WATERCOOLED & CONDENSERLESS LIQUID CHILLERS AND HEAT PUMPS FOR COMMERCIAL & INDUSTRIAL APPLICATION. REMOTE CONDENSERS Unit Page CWW/K 8-9 CWW/K 8-P 0-P 0 - CWW/K 8 0 - MEA/K - MEA/K 8-P 0-P - RCA/K

More information

Optyma Slim Pack Just mount, braze and plug

Optyma Slim Pack Just mount, braze and plug Optyma Slim Pack Just mount, braze and plug R0A/R07, Ra, R07A, R07F - 0Hz http://cc.danfoss.com Content The cost effective outdoor solution... Features and cooling capacity... Main product features...

More information

Semi-hermetic Air-cooled Condensing Units

Semi-hermetic Air-cooled Condensing Units Semi-hermetic Air-cooled Condensing Units For Indoor and Outdoor Applications DFA-002-1 R22 R404A R507 R22 DFA Indoor Model Standard Features Bitzer OCTAGON series compressors up to 7 ½ HP. Dual adjustable

More information

MOLLIER DIAGRAM CAN BE IMPROVED!

MOLLIER DIAGRAM CAN BE IMPROVED! MOLLIER DIAGRAM CAN BE IMPROVED! IMPROVED BASIC COOLING CIRCUIT PERFORMANCE EFFICIENCY USING AN ECONOMISER Eng. Jonny Malachi, VP Operations, Mashav Refrigeration and Air Conditioning Engineering Ltd.

More information

IT COOLING EVAPORATIVE COOLING SYSTEM. 2 STAGE INDIRECT ADIABATIC COOLING SYSTEM FOR LARGE DATA CENTERS FROM 80 TO 320 kw

IT COOLING EVAPORATIVE COOLING SYSTEM. 2 STAGE INDIRECT ADIABATIC COOLING SYSTEM FOR LARGE DATA CENTERS FROM 80 TO 320 kw IT COOLING EVAPORATIVE COOLING SYSTEM 2 STAGE INDIRECT ADIABATIC COOLING SYSTEM FOR LARGE DATA CENTERS FROM 8 TO 3 kw IT COOLING EVAPORATIVE COOLING SYSTEM ADIABATIC COOLING FOR HIGH EFFICIENCY - Variable

More information

Electrically operated expansion valves, type ETS 25 and 12½ REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Electrically operated expansion valves, type ETS 25 and 12½ REFRIGERATION AND AIR CONDITIONING. Technical leaflet Electrically operated expansion valves, type ETS 25 and 12½ REFRIGERATION AND AIR CONDITIONING Technical leaflet Contents Page Introduction........................................................................................3

More information

ZTE ZXCR Series DX In-Row Air Conditioning Product Description

ZTE ZXCR Series DX In-Row Air Conditioning Product Description ZTE ZXCR Series DX In-Row Air Conditioning Product Description Requirements & Challenges Due to the rapid development of telecommunication technology, the related IT equipment s power consumption is increase

More information

J&M Fluidics, Inc. Company Product Overview

J&M Fluidics, Inc. Company Product Overview It s All about Building a Better Product for Our Clients! J&M Fluidics, Inc. Company Product Overview J&M Fluidics, Manufacturer of Air & Water-Cooled Process Chillers. Located in Telford, Pennsylvania

More information

Assembly and Maintenance

Assembly and Maintenance Assembly and Maintenance Assembly and Maintenance Test Pumps Pressure Test Pumps Tests all types of installations such as heating, compressed air and refrigeration systems, oil installations, fire lines

More information

HIGH EFFICIENCY 15 and 17 SEER TWO STAGE HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT. Min. Circuit Ampacity

HIGH EFFICIENCY 15 and 17 SEER TWO STAGE HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT. Min. Circuit Ampacity ENVIRONMENTALLY SOUND REFRIGERANT C4H(5, 7) Product Specifications HIGH EFFICIENCY 15 and 17 TWO STAGE HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 2, 3, 4, and 5 TONS SPLIT SYSTEM 208 / 230 Volt,

More information

DUCTED SPLIT SYSTEMS With Scroll compressors

DUCTED SPLIT SYSTEMS With Scroll compressors DUCTED SPLIT SYSTEMS With Scroll compressors 2 Benefits TOTAL COMFORT ON WIDE AREAS The Ducted Blower Split Systems for light commercial applications of DXDXT-M/K series are the ideal solution for keeping

More information

How To Draw Chiller Monsters Werewolves Vampires And Zombies

How To Draw Chiller Monsters Werewolves Vampires And Zombies How To Draw Chiller Monsters Werewolves Vampires And Zombies We have made it easy for you to find a PDF Ebooks without any digging. And by having access to our ebooks online or by storing it on your computer,

More information

AIR COOLED CONDENSERS

AIR COOLED CONDENSERS AIR COOLED CONDENSERS NQAC Quiet Line HNSQAC NQAC Quiet Line kw () Highly efficient external rotor fan motors give optimum performance with low noise levels Multiple fans (on all except smallest models)

More information

CHAPTER 1. Unit CHA/IK/WP CHA/CLK CHA/ML/ST CHA/ML/ST CHA/ML/ST 182-P 302-P 50-51

CHAPTER 1. Unit CHA/IK/WP CHA/CLK CHA/ML/ST CHA/ML/ST CHA/ML/ST 182-P 302-P 50-51 CHAPTER AIRCOOLED LIQUID CHILLERS AND HEAT PUMPS FOR RESIDENTIAL & LIGHT COMMERCIAL APPLICATION Unit Page CHA/IK/WP - CHA/CLK 8 - CHA/ML/ST - CHA/ML/ST 9 8-9 CHA/ML/ST 8-P 0-P 0 - FROM, KW TO KW. CHA/IK/WP

More information

System User Manual. AKC 55 Rack Controller

System User Manual. AKC 55 Rack Controller System User Manual AKC 55 Rack Controller This User s Manual contains installation, start-up, and operating instructions for all parts of the Danfoss AKCESS System. Use the Table of Contents to find the

More information

Hoshizaki America, Inc.

Hoshizaki America, Inc. Hoshizaki America, Inc. Low-Profile Modular Crescent Cuber Models KML-351MAH KML-351MWH A Superior Degree of Reliability PARTS LIST www.hoshizaki.com Number: 71267 Issued: 5-9-2008 Revised: 10-13-2014

More information

New Design Strategies for Energy Saving. Intelligent free-cooling

New Design Strategies for Energy Saving. Intelligent free-cooling New Design Strategies for Energy Saving Intelligent free-cooling Intelligent New strategies for energy saving When designing mission critical systems for processing applications or highly technological

More information

70% of the chiller value reduces development costs

70% of the chiller value reduces development costs Danfoss Solutions for Chillers Better chillers from the inside out Strict regulations, a competitive marketplace, and the need to optimize system costs compel you to update your chiller designs. Building

More information

Pressure switch KP. Data sheet

Pressure switch KP. Data sheet Data sheet Pressure switch KP KP switchs are for use in refrigeration and air conditioning systems to give protection against excessively low suction or excessively high discharge. KP switches are also

More information

Pressure switch Type KP

Pressure switch Type KP MAKING MODERN LIVING POSSIBLE Data sheet Pressure switch Type KP KP switchs are for use in refrigeration and air conditioning systems to give protection against excessively low suction or excessively high

More information

High Efficient Data Center Cooling

High Efficient Data Center Cooling Nordborg High Efficient Data Center Cooling Copenhagen Center on Energy Efficiency webinar 12. July 2017 Jörg Saar, Danfoss Cooling 1 Danfoss Cooling Contents 1. Short intro to Danfoss Cooling 2. Introduction

More information

Precision Cooling for Business-Critical Continuity. Liebert HPC-S. Designed for the Efficient Cooling of Small Data Centers

Precision Cooling for Business-Critical Continuity. Liebert HPC-S. Designed for the Efficient Cooling of Small Data Centers Precision Cooling for Business-Critical Continuity Liebert HPC-S Designed for the Efficient Cooling of Small Data Centers Liebert HPC-S: Enhanced Efficiency Freecooling Chiller Higher energy costs, limited

More information

R410A D2D_AU019E/

R410A D2D_AU019E/ R41A 2. : AUU18RCLX AUU24RCLX D2D_AU19E/ 27.6.11 2-1. FEATURE MODELS : AUU18RCLX / AOU18RLX AUU24RCLX / AOU24RLX FEATURES Easy maintenance The control box is easily accessible for maintenance work Wide

More information

Kirby NK Heavy Commercial Industrial Unit Cooler. Natural fluids: Glycol water

Kirby NK Heavy Commercial Industrial Unit Cooler. Natural fluids: Glycol water Kirby NK Heavy Commercial Industrial Unit Cooler Natural fluids: Glycol water MT 20kW LT 16kW 110kW 68kW Product Overview > The NK range is designed for industrial refrigeration, storage or deep-freezing

More information

Ecoflair Air Economizers

Ecoflair Air Economizers Ecoflair Air Economizers Cooling to maximize value for the cloud schneider-electric.com/ecoflair Life is On Schneider Electric 1 Ecoflair takes data center efficiency to new heights 2 Imagine cooling your

More information

Slim duct (AMTTTFNLDEH ) Indoor units

Slim duct (AMTTTFNLDEH ) Indoor units Slim duct (AMTTTFNLDEH ) Slim duct. Specifications 1) Technical specifications Model AM22FNLDEH AM28FNLDEH AMFNLDEH AM4FNLDEH AMFNLDEH Power Supply Ø, #, V, Hz 1,2,22-24, 1,2,22-24, 1,2,22-24, 1,2,22-24,

More information

Modeling of Compressors and Expansion Devices With Two-Phase Refrigerant Inlet Conditions

Modeling of Compressors and Expansion Devices With Two-Phase Refrigerant Inlet Conditions Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2006 Modeling of Compressors and Expansion Devices With Two-Phase Refrigerant

More information

Pressure Test Pumps. Test Pump. Electric Test Pump. Assembly and Maintenance Test Pumps

Pressure Test Pumps. Test Pump. Electric Test Pump. Assembly and Maintenance Test Pumps Assembly and Maintenance Test Pumps Pressure Test Pumps Tests all types of installations such as heating, compressed air and refrigeration systems, oil installations, fire lines and small bore pipelines.

More information

Submersible Pumps. Pumping Solution. 50 Hz

Submersible Pumps. Pumping Solution. 50 Hz Submersible Pumps Pumping Solution 0 Hz INTRODUCTION Submersible bore well pumps for (DN 0 mm), (DN 0 mm), (DN 0 mm), (DN 00mm), (DN 0 mm) and (DN 00 mm) wells. Sized for connection to the motor according

More information

Air-Cooled Series R Chiller

Air-Cooled Series R Chiller Air-Cooled Series R Chiller The next generation of Air-Cooled Helical Rotary Chillers ANOTHER RELIABLE SOURCE OF CHILLED WATER FROM TRANE The new industry standard f The next generation of the air-cooled

More information

FX 2 Instruction Manual

FX 2 Instruction Manual FX 2 Instruction Manual Climma Compact Version Annapolis MD USA 301 352 6962 info@veco-na.com Introduction: The FX2-DX digital controller operates onboard air conditioning equipment to provide room temperature

More information

NIR Moisture Analyzer KB-30

NIR Moisture Analyzer KB-30 NIR Moisture Analyzer KB-30 Operation Manual Safety Precautions FPL950701 Improper use of the NIR moisture analyzer in violation of the following safety notes may result in death, injury or damage to property

More information

Min. Circuit Ampacity. Max. Fuse or Breaker. Ship / Operating Weight lbs. (kg) C4H524GKD 2 24,

Min. Circuit Ampacity. Max. Fuse or Breaker. Ship / Operating Weight lbs. (kg) C4H524GKD 2 24, ENVIRONMENTALLY SOUND REFRIGERANT C4H(5, 7) SXT+ Product Specifications HIGH EFFICIENCY 15 and 17 SEER TWO STAGE HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 2, 3, 4, and 5 TONS SPLIT SYSTEM 208

More information

Your Solution For Energy and Cost Savings. McQuay Packaged Chiller Plant

Your Solution For Energy and Cost Savings. McQuay Packaged Chiller Plant Your Solution For Energy and Cost Savings McQuay Packaged Chiller Plant Innovative Solutions for Your Chiller Plant McQuay packaged chiller plants provide energy efficient chillers integrated with pumps,

More information

CONDENSING UNITS UASL- JEC

CONDENSING UNITS UASL- JEC FORM NO. A22-196 3 Supersedes Form No. A22-196 Rev. 2 CONDENSING UNITS Equipped with Comfort Control 2 System Serial communication enabled Increased system reliability and efficiency 32+ on-board diagnostic

More information

Spare parts manual. SAB Screw compressor unit

Spare parts manual. SAB Screw compressor unit Spare parts manual en SAB 120-151 Screw compressor unit Contents 1. Service parts list SAB 120/151 2 1.1.1 How to use the spare parts list 2 1.1.2 Recommended spare parts 4 1.1.4 General arrangement SAB

More information

Aquaflair. BREC & BREF kW 380V/3ph/60Hz - 460V/3ph/60Hz. Air-cooled chillers and free-cooling chillers with double screw compressors

Aquaflair. BREC & BREF kW 380V/3ph/60Hz - 460V/3ph/60Hz. Air-cooled chillers and free-cooling chillers with double screw compressors Aquaflair Air-cooled chillers and free-cooling chillers with double screw compressors BREC & BREF 350-1200kW 380V/3ph/60Hz - 460V/3ph/60Hz The all-in-one solution for your business need Combining cutting-edge

More information

CTC Low Temperature Process Chillers

CTC Low Temperature Process Chillers INNOVATE DESIGN APPLY CTC Low Temperature Process Chillers 5-500 Tons OUR BUSINESS IS COOLING YOURS TM When commercial grade isn t enough When it comes to process cooling, every application is unique in

More information

Pressure controls, Type KP

Pressure controls, Type KP MAKING MODERN LIVING POSSIBLE Technical brochure Pressure controls, Type KP KP pressure controls are for use in refrigeration and air conditioning systems to give protection against excessively low suction

More information

U-Match Series DC Inverter Service Manual PRODUCT

U-Match Series DC Inverter Service Manual PRODUCT PRODUCT 1 PRODUCT 1 MODELS LIST 1.1 Outdoor Unit Name Product Code Power Supply (V, Ph, Hz) Appearance GUHD24NS3GO CF090W0800 220-240V~ 50/60Hz GUHD36NS3GO CF090W0860 220-240V~ 50/60Hz GUHD42NS3GO CF090W0870

More information

SINGLE. Technical Data Book. Big Duct for EU (R410A, 50Hz, HP) Model : IDU : AC***KNHPKH/EU ODU : AC***KXAPNH/EU

SINGLE. Technical Data Book. Big Duct for EU (R410A, 50Hz, HP) Model : IDU : AC***KNHPKH/EU ODU : AC***KXAPNH/EU SINGLE Technical Data Book Big Duct for EU (R4A, 0Hz, HP) Model : IDU : AC***KNHPKH/EU ODU : AC***KXAPNH/EU History Version Modification Date Remark Ver 1.0 Release SINGLE Big Duct for EU (R4A, 0Hz, HP)

More information

shop online:

shop online: Process systems Liquid ring vacuum pumps Single stage pumps 8 Alpha series single stage liquid ring vacuum pumps 9 AL series single stage liquid ring vacuum pumps 97 Two stage pumps 00 SHR series liquid

More information

Liquid Level Monitoring System LW4/LW5 - Low or High Level Control

Liquid Level Monitoring System LW4/LW5 - Low or High Level Control Liquid Level Monitoring System /LW5 - Low or High Level Control Technical Bulletin and LW5 are self-contained units intended for liquid level monitoring at the sight glass or plugged connection of vessels,

More information

NOTE ON PERFORMANCE TESTING

NOTE ON PERFORMANCE TESTING NOTE ON PERFORMANCE TESTING Performance Profile Sheet(s) are included in a format that can be easily photocopied for each trainee. This examination is designed to measure competency in the tasks taught

More information

IT COOLING AIR CONDITIONERS FOR HIGH DENSITY RACKS AND BLADE SERVERS. RACK COOLING SOLUTIONS FOR HIGH DENSITY RACK MANAGEMENT, FROM 4 TO 75 kw

IT COOLING AIR CONDITIONERS FOR HIGH DENSITY RACKS AND BLADE SERVERS. RACK COOLING SOLUTIONS FOR HIGH DENSITY RACK MANAGEMENT, FROM 4 TO 75 kw IT COOLING AIR CONDITIONERS FOR HIGH DENSITY RACKS AND BLADE SERVERS RACK COOLING SOLUTIONS FOR HIGH DENSITY RACK MANAGEMENT, FROM 4 TO 75 kw IT COOLING AIR CONDITIONERS FOR HIGH DENSITY RACKS AND BLADE

More information

Capacity controller for small CO2 booster refrigeration system AK-PC 772 REFRIGERATION AND AIR CONDITIONING. Manual

Capacity controller for small CO2 booster refrigeration system AK-PC 772 REFRIGERATION AND AIR CONDITIONING. Manual Capacity controller for small CO2 booster refrigeration system AK-PC 772 REFRIGERATION AND AIR CONDITIONING Manual Contents 1. Introduction...3 Application... 3 Principles... 4 2. Design of a controller...7

More information

Capacity controller for small CO2 refrigeration system AK-PC 772A

Capacity controller for small CO2 refrigeration system AK-PC 772A User Guide Capacity controller for small CO2 refrigeration system AK-PC 772A ADAP-KOOL Refrigeration control systems Contents 1. Introduction...3 Application... 3 Principles... 4 2. Design of a controller...7

More information

Aquaflair. Uniflair TRAC, TRAF and TRAH. Air-cooled chillers, free-cooling chillers and heat pumps with scroll compressors.

Aquaflair. Uniflair TRAC, TRAF and TRAH. Air-cooled chillers, free-cooling chillers and heat pumps with scroll compressors. Aquaflair Uniflair TRAC, TRAF and TRAH Air-cooled chillers, free-cooling chillers and heat pumps with scroll compressors 120-350kW Uniflair TRA ranges 115-350kW Air-cooled Chillers Cooling, Free cooling

More information

VRF. Technical Data Book. DVM S Eco 8, 9 HP

VRF. Technical Data Book. DVM S Eco 8, 9 HP VRF Technical Data Book DVM S Eco 8, 9 HP Version Modification Date Remark Ver.1.0 Released DVM S Eco 8,9HP TDB.06.26 Ver.1.1 Max pipe length modified(equivalent length) : 0 -> 130m 15.04.07 Nomenclature

More information

McQuay. Water Source Heat Pump Large Vertical. VWG, VWH, VWW Vintage D. Last Manufactured: 1997

McQuay. Water Source Heat Pump Large Vertical. VWG, VWH, VWW Vintage D. Last Manufactured: 1997 Replacement Parts List No. 057103800 Revision D 02/2017 McQuay Water Source Heat Pump Large Vertical VWG, VWH, VWW 07-27 Vintage D Last Manufactured: 1997 To find your Daikin Applied parts distributor,

More information

IntesisBox. v.0.1. User Manual Issue Date: 12/2017 r1.3 EN

IntesisBox. v.0.1. User Manual Issue Date: 12/2017 r1.3 EN IntesisBox HS-RC-MBS-1 v.0.1 Modbus RTU (EIA-485) Interface for Hisense air conditioners. Compatible with commercial line of air conditioners commercialized by Hisense. User Manual Issue Date: 12/2017

More information

14ACX. MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,700 to 58,000 Btuh. 14 AC x MODEL NUMBER IDENTIFICATION

14ACX. MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,700 to 58,000 Btuh. 14 AC x MODEL NUMBER IDENTIFICATION E N G I N E E R I N G D ATA A I R C O N D I T I O N E R S 14ACX MERIT Series R-410A Bulletin 210475 October 2009 Supersedes March 2009 SEER up to 15.5 1.5 to 5 Tons Cooling Capacity - 17,700 to 58,000

More information

KLP. Low Profile Evaporators CONTENTS PRODUCT DATA & INSTALLATION

KLP. Low Profile Evaporators CONTENTS PRODUCT DATA & INSTALLATION PRODUCT DATA & INSTALLATION Bulletin K30-KLP-PDI-16 Part # 1087150 PRODUCT SUPPORT web: k-rp.com/klp email: evaps@k-rp.com call: 1-844-893-3222 x520 scan: KLP Low Profile Evaporators Air, Electric, Hot

More information

H.A. Phillips Inventory Overstock Liquidation List

H.A. Phillips Inventory Overstock Liquidation List H.A. Phillips Inventory Overstock Liquidation List ALL PRICES HAVE BEEN REDUCED All Items subject to verification of stocking. Items are sold as is. Please contact the factory (630-377-0050) for more information.

More information

Premium Precision Soldering station

Premium Precision Soldering station www.jbctools.com English Premium Precision Soldering station Ref. DIR-D 2 www.jbctools.com Packing List The following items should be included: DI Control Unit... 1 unit Ref. DI-1D (120V) DI-2D (230V)

More information

DAIKIN GAS TIGHT JOINT (DGT)

DAIKIN GAS TIGHT JOINT (DGT) LINE UP Model Name Size (mm) DAIKIN GAS TIGHT JOINT (DGT) SPECIFICATIONS BDGTA06 ø 6.4 BDGTA06 ø 9.5 BDGTA12 ø 12.7 BDGTA15 ø 15.9 BDGTA19 ø 19.1 BDGTA22 ø 22.2 BDGTA28 ø 28.6 DAIKIN GAS TIGHT JOINT Applicable

More information

Pressure switch KP. Data sheet

Pressure switch KP. Data sheet Data sheet Pressure switch KP The KP pressure switches can be used as safety switches against too low a suction pressure and / or too high a discharge pressure in refrigeration and air conditioning systems.

More information

Thermal DC-DC Control System TEC Series

Thermal DC-DC Control System TEC Series Thermal DC-DC Control System TEC 54100 Series Thermal DC-DC Control System TEC 54100 Series Bidirectional driving with 150W (24V 8A), 300W (24V 13A), or 800W (40V 20A) output Filtered PWM output with >

More information

Chiller. CG 010 to 130. Remote Air Cooled Condensers Engineering Data Manual. 9.4 to 131 kw

Chiller. CG 010 to 130. Remote Air Cooled Condensers Engineering Data Manual. 9.4 to 131 kw Chiller CG 010 to 130 Remote Air Cooled Condensers Engineering Data Manual 9.4 to 131 kw Specifications Unit identification CG. O. O55. FSC. R407C LN Configuration Refrigerant rpm fans Size Air flow Remote

More information

Aquaflair. BREC/F and BCEC/F kw

Aquaflair. BREC/F and BCEC/F kw Aquaflair Air-cooled chillers and free-cooling chillers with screw or oil-free centrifugal compressors equipped with adiabatic system BREC/F and BCEC/F 350-1350 kw Dualism for evolution: the combination

More information

Product Brochure DENCO Close Control Units Row-DENCO. High Density Cooling for Data Centres

Product Brochure DENCO Close Control Units Row-DENCO. High Density Cooling for Data Centres Product Brochure DENCO Close Control Units Row-DENCO High Density Cooling for Data Centres Data Centre Cooling Through a history in close control, we have developed a broad and deep understanding of how

More information

Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for Single-Phase Motors

Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for Single-Phase Motors European Refrigeration Controls Catalogue Catalogue Section 4 Product Bulletin P215PR/RM Issue August 2016 Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for

More information

Motivair MLC-SC Air-Cooled Scroll Chillers Tons

Motivair MLC-SC Air-Cooled Scroll Chillers Tons INNOVATE DESIGN APPLY www.motivaircorp.com Motivair MLC-SC Air-Cooled Scroll Chillers 100 285 Tons OUR BUSINESS IS COOLING YOURS. When commercial grade isn t enough Businesses who function in today s advanced

More information

SmoothAir Modular Precision Cooling

SmoothAir Modular Precision Cooling TM SmoothAir Modular Precision Cooling ODM/OEM/Customization+ Specialist Support+ Modular Precision Cooling for Smart, Reliable and Green MDC Solution Why Choose Us Products Support Customization Products

More information

Insignia - Icon SPARE PARTS CATALOG LASER MARKING SYSTEMS

Insignia - Icon SPARE PARTS CATALOG LASER MARKING SYSTEMS Insignia - Icon LASER MARKING SYSTEMS 1998-2005 To Order Parts Contact: 1(866) 612-8619 / Fax: (407) 926-3551 or Visit Our Website: TABLE OF CONTENTS Insignia - Icon DESCRIPTION PAGE Insignia Control Cabinet

More information

SECO THERMOSTAT Gas/electric 24 volt, heating, cooling mercury switch, ivory color

SECO THERMOSTAT Gas/electric 24 volt, heating, cooling mercury switch, ivory color CAUDILL SUPPLY INC. Page 1 SECO THERMOSTAT Gas/electric 24 volt, heating, cooling mercury switch, ivory color AC 3050 SECO HEAT PUMP THERMOSTAT 2 stage heat, 1 stage cool, 24 volt, manual change over,

More information

HIGH EFFICIENCY 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R-410A REFRIGERANT

HIGH EFFICIENCY 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R-410A REFRIGERANT ENVIRONMENTALLY SOUND REFRIGERANT H4A4 DX 1400 Product Specifications HIGH EFFICIENCY 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1-phase, 60 Hz

More information

Future of Cooling High Density Equipment. Steve Madara Vice President and General Manager Liebert Precision Cooling Business Emerson Network Power

Future of Cooling High Density Equipment. Steve Madara Vice President and General Manager Liebert Precision Cooling Business Emerson Network Power Future of Cooling High Density Equipment Steve Madara Vice President and General Manager Liebert Precision Cooling Business Emerson Network Power Agenda Issues facing the Data Center Managing the explosive

More information

Thermostat KP. Data sheet. The KP Thermostats are single-pole, doublethrow (SPDT) temperature-operated electric switches.

Thermostat KP. Data sheet. The KP Thermostats are single-pole, doublethrow (SPDT) temperature-operated electric switches. Data sheet Thermostat KP The KP Thermostats are single-pole, doublethrow (SPDT) temperature-operated electric switches. They can be connected directly to a single-phase AC motor of up to approx. 2 kw or

More information

COOLING SOLUTIONS BY LABTECH INNOVATION INSPIRED

COOLING SOLUTIONS BY LABTECH INNOVATION INSPIRED WATER CHILLERS COOLING SOLUTIONS COOLING SOLUTIONS BY LABTECH Even if water is one of the most precious and scarce resources, it is still largely used as coolant in many laboratories. Most of the water

More information

Product Data. SYNERGY TDA (60 Hz) Two-Speed Electric Air Conditioner. Sizes 036, 048, and 060 FEATURES/BENEFITS

Product Data. SYNERGY TDA (60 Hz) Two-Speed Electric Air Conditioner. Sizes 036, 048, and 060 FEATURES/BENEFITS Product Data SYNERGY 2000 38 TDA (60 Hz) Two-Speed Electric Air Conditioner Sizes 036, 048, and 060 Model 38TDA Air Conditioners incorporate innovative 2-speed compressor technology to provide quiet, efficient

More information

Standard Circulating Pumps

Standard Circulating Pumps Product review Range: 1 1 3Q [ m³/h] Hz - North America 1 3 1 1 1.x1 1.x x x3 x 1 1 Q [ US gpm] >Single-head pumps: Circulating pumps with flanged connection > Applications: Drinking-water circulation

More information

NEOSTAR AXIAL FAN CONDENSER COMMERCIAL AND INDUSTRIAL RANGE HFC. 18 > 1240 kw. NEOSTAR POWER The choice of performance and low space requirement.

NEOSTAR AXIAL FAN CONDENSER COMMERCIAL AND INDUSTRIAL RANGE HFC. 18 > 1240 kw. NEOSTAR POWER The choice of performance and low space requirement. AXIAL FAN CONDENSER COMMERCIAL AND INDUSTRIAL RANGE Hard Discount - Supermarkets - Hypermarkets Refrigerated storage and transit stocking - Dispatch centres Food processing - Canteen kitchens HFC 18 >

More information

IM Installation Manual. Pathfinder Remote Evaporators Air-Cooled Screw Compressor Chillers

IM Installation Manual. Pathfinder Remote Evaporators Air-Cooled Screw Compressor Chillers Installation Manual Pathfinder Remote Evaporators Air-Cooled Screw Compressor Chillers IM 1203-2 Group: Chiller Part Number: IM1203-2 Date: February 2016 Model AWS, C Vintage 170 to 550 Tons (600 to 1930

More information

Jaga-Deco Pro thermostatic valves

Jaga-Deco Pro thermostatic valves Valves Range Jaga-Deco manual valves Jaga-Deco Pro thermostatic valves Jaga-Deco thermostatic valves for single point connection - manual chrome-plated valve for connection to the wall or to the floor

More information

CPC1964BX6. Rapid Turn-On AC Power Switch INTEGRATED CIRCUITS DIVISION. Description. Features. Approvals. Ordering Information.

CPC1964BX6. Rapid Turn-On AC Power Switch INTEGRATED CIRCUITS DIVISION. Description. Features. Approvals. Ordering Information. Rapid Turn-On AC Power Switch Parameter Rating Units AC Operating Voltage - 24 V rms Load Current 1. A rms On-State Voltage Drop 1.4 V P (at = 1.A P Blocking Voltage 6 V P Features Load Current up to 1.A

More information

Precision Cooling for Business-Critical Continuity. Liebert HPC-M. The Data Center FreeCooling Chiller with the Lowest Impact on the Environment

Precision Cooling for Business-Critical Continuity. Liebert HPC-M. The Data Center FreeCooling Chiller with the Lowest Impact on the Environment Precision Cooling for Business-Critical Continuity Liebert HPC-M The Data Center FreeCooling Chiller with the Lowest Impact on the Environment Emerson Network Power, a division of Emerson Electric Co.,

More information

Pressure switch KP. Data sheet

Pressure switch KP. Data sheet Data sheet Pressure switch KP The KP pressure switches can be used as safety switches against too low a suction pressure and / or too high a discharge pressure in refrigeration and air conditioning systems.

More information

ENGINEERED VALUE WORLDWIDE DESIGNING PUMPS INTO INK SUPPLY SYSTEMS

ENGINEERED VALUE WORLDWIDE DESIGNING PUMPS INTO INK SUPPLY SYSTEMS ENGINEERED VALUE WORLDWIDE DESIGNING PUMPS INTO INK SUPPLY SYSTEMS WIR SIND KNF - INTRO WE ARE KNF A LEADER FOR CUSTOMIZED PUMPS AND SYSTEMS OVERVIEW INK SUPPLY SYSTEMS Ink supply to printheads Two main

More information

1.5 to 5 Tons INDOOR COILS C35. Upflow - Cased and Uncased PRODUCT SPECIFICATIONS C A - 2 F - 1 MODEL NUMBER IDENTIFICATION FEATURES

1.5 to 5 Tons INDOOR COILS C35. Upflow - Cased and Uncased PRODUCT SPECIFICATIONS C A - 2 F - 1 MODEL NUMBER IDENTIFICATION FEATURES INDOOR COILS C35 PRODUCT SPECIFICATIONS Upflow - Cased and Uncased Bulletin No. 20666 February 208 Supersedes November 206.5 to 5 Tons MODEL NUMBER IDENTIFICATION Unit Type C = Indoor Coil = Upflow Series

More information

GP SERIES Packaged Chillers

GP SERIES Packaged Chillers Blending Conveying Drying Process Cooling Heat Transfer Size Reduction GP SERIES Packaged Chillers Comprehensive Flexible Versatile Compact unitary designs available in a variety of configurations from

More information

A Data Center Heat Removal System That Saves... 80% Discover Inertech s Award-winning Data Center Heat Removal System

A Data Center Heat Removal System That Saves... 80% Discover Inertech s Award-winning Data Center Heat Removal System A Data Center Heat Removal System That Saves... Infrastructure Power Water up to 40% up to 80% up to 85% Discover Inertech s Award-winning Data Center Heat Removal System A Cool Solution; A Breakthrough

More information

IntesisBox DK-RC-MBS-1 v.0.2

IntesisBox DK-RC-MBS-1 v.0.2 IntesisBox DK-RC-MBS-1 v.0.2 MODBUS RTU (RS-485) Interface for Daikin air conditioners. Compatible with VRV and SKY line air conditioners commercialized by Daikin. User Manual Issue Date: 2011/05/05 Order

More information

TRITIUM COLLECTION SYSTEMS

TRITIUM COLLECTION SYSTEMS F&J SPECIALTY PRODUCTS, INC. The Nucleus of Quality Air Monitoring Programs TRITIUM COLLECTION SYSTEMS 100 120 VAC KH3-200 MRB200H3 MRB200H3-60ML MRB500H3 TCS-3000-BL TCS-5000-BLDC Rev: 13 June 2018 Tel:

More information

SCADA. EDIBON Computer Control System: Computer Control + Data Acquisition + Data Management Cables to. Cable to computer. Control.

SCADA. EDIBON Computer Control System: Computer Control + Data Acquisition + Data Management Cables to. Cable to computer. Control. Technical Equipment Computer led Heat Pump Unit (one condenser (water) and one evaporator (water)) THBLLC Always included in the supply: SCADA. EDIBON Computer System 2 Interface Box 5 Cables and Accessories

More information

IntesisBox DK-RC-MBS-1 v.0.8

IntesisBox DK-RC-MBS-1 v.0.8 IntesisBox DK-RC-MBS-1 v.0.8 MODBUS RTU (RS-485) Interface for Daikin air conditioners. Compatible with VRV and SKY line air conditioners commercialized by Daikin. User Manual Issue Date: 2013/02/26 Order

More information

Efficiency of Data Center cooling

Efficiency of Data Center cooling Efficiency of Data Center cooling Comparison of data room layouts and cooling systems Bohumil Cimbal Product manager for Cooling Systems in CONTEG Company Objective Basic questions between investor and

More information

RTAA CONTROLS UPGRADE

RTAA CONTROLS UPGRADE MCS Total Solutions for all your HVAC/R Control Needs RTAA CONTROLS UPGRADE This brochure describes a standard upgrade package for the RTAA Chiller. Each Control upgrade installation is unique. It may

More information

Models: WA182, WA242. Contents. Cabinet Components. Control Panel. Blower Assembly. BARD MANUFACTURING COMPANY Bryan, Ohio 43506

Models: WA182, WA242. Contents. Cabinet Components. Control Panel. Blower Assembly. BARD MANUFACTURING COMPANY Bryan, Ohio 43506 REPLACEMENT PARTS MANUAL WALL MOUNTED PACKAGE AIR CONDITIONER Models: WA182, WA242 General Notes Ø Ø Revised and/or additional pages may be issued from time to time. A complete and current manual consists

More information

InRow Chilled Water. Up to 70kW. Close-coupled, chilled water cooling for medium to large data centers. Row-Based Cooling.

InRow Chilled Water. Up to 70kW. Close-coupled, chilled water cooling for medium to large data centers. Row-Based Cooling. InRow Chilled Water Close-coupled, chilled water cooling for medium to large data centers Up to 0kW > Row-Based Cooling The InRow Chilled Water product design closely couples the cooling with the IT heat

More information

100% Warm-Water Cooling with CoolMUC-3

100% Warm-Water Cooling with CoolMUC-3 100% Warm-Water Cooling with CoolMUC-3 No chillers, no fans, no problems Axel Auweter MEGWARE CTO Workshop on Energy Efficiency in HPC May 30, 2018, Ljubljana!1 MEGWARE Computer Vertrieb und Service GmbH

More information

Product Data. 25HNA9 Infinityt 19 Series Heat Pump with Puronr Refrigerant 2 To 5 Tons Nominal (Size 24 To 60) INDUSTRY LEADING FEATURES / BENEFITS

Product Data. 25HNA9 Infinityt 19 Series Heat Pump with Puronr Refrigerant 2 To 5 Tons Nominal (Size 24 To 60) INDUSTRY LEADING FEATURES / BENEFITS Infinityt 19 Series Heat Pump with Puronr Refrigerant 2 To 5 Tons Nominal (Size 24 To 60) the environmentally sound refrigerant Carrier s heat pumps with Puronr refrigerant provide a collection of features

More information

MAKING MODERN LIVING POSSIBLE. ADAP-KOOL Drive. A New Drive for Energy Efficiency AKD 102 REFRIGERATION & AIR CONDITIONING DIVISION

MAKING MODERN LIVING POSSIBLE. ADAP-KOOL Drive. A New Drive for Energy Efficiency AKD 102 REFRIGERATION & AIR CONDITIONING DIVISION MAKING MODERN LIVING POSSIBLE REFRIGERATION & AIR CONDITIONING DIVISION ADAP-KOOL Drive A New Drive for Energy Efficiency AKD 102 2 The AKD 102 comes with a common user interface and covers power ratings

More information