1 Representatives Meeting June 7, 2017 Oil insulated instrument transformers Reimund Gross Product Manager High-Voltage ITs
2 Outdoor instrument transformers Current transformers kv Inductive VT kv Combined transformers kv Capacitive VT kv / page 2 /
3 Current transformers Oil-paper insulated kv Head type with two head sizes, up to 72 kv also tank type available Simple primary winding changeover Explosion tested housing JOF 123 JOF 420 G / page 3 /
4 Inductive voltage transformers Oil-paper insulated kv Working at low induction With open delta winding and damping unit Ferro resonance can be minimized Generously-sized terminal box EOF 123 EOF / page 4 /
5 Combined instrument transformers Oil-paper insulated kv Combines all advantages of current and voltage transformers Guaranteed accuracy over entire service life New member of Oil Family: EJOF G / page 5 /
6 Capacitive voltage transformers Oil-paper insulated kv Ferro-resonance-free Custom made design Various features available / page 6 /
7 Combined Transformer cross section Bellows cover with oil expansion indicator Lifting lugs CT part with iron cores, secondary windings and high voltage insulation Expansion bellows Housing with drainage area Primary terminal Primary reconnection Bushings VT part primary winding and high voltage insulation Terminal box with rating plate Secondary windings Iron core of VT Main earth terminal Oil drain valve / page 7 /
8 Composite vs. Porcelain insulator Composite Important improve of the explosion security Considerable better behaviour under rain and heavy pollution Hydrophobicity / page 8 /
9 Composite Insulator - Hydrophobicity New 21 years in industrial environment / page 9 /
10 Composite vs. Porcelain insulator Composite Porcelain Important improve of the explosion security Considerable better behaviour under rain and heavy pollution Hydrophobicity Easier handling due to lower weight and less fragility Reduce over all weight of the instrument transformer Less risks of damages during transport and installation Less risks of vandalism long term experience reliable Use of single shed or alternating shed design Use of porcelain type C130 (aluminium oxide) Cementing up to 245kV in house / page 10 /
11 Secondary terminals Screw terminals Woertz Spring-type terminals Wago Tobjob Bolt terminals M10 Pfiffner design Other terminals on request e. g. Phoenix, Weidmüller, Conexel most customer requirements can be fulfilled / page 11 /
12 Primary reconnection Pfiffner Instrument transformers kV are equipped with an easy primary reconnection. Access only from one side necessary (P2). One single pad to modify the ratio. / page 12 /
13 Primary reconnection Pfiffner Instrument transformers kV are equipped with an easy primary reconnection. Access only from one side necessary (P2). One single pad to modify the ratio. Clear schematic diagram for connection incl. max. torque for screws. Reduces risks of wrong connection to an absolute minimum. 300 A 600 A 1200 A / page 13 /
14 Primary reconnection /1 Number of primary turns: 1 : 2 : 4 Number of secondary turns: / page 14 /
15 Primary reconnection Special primary reconnection for higher currents (> 3000 A) Special, expensive parts (copper parts, flex parts) / page 15 /
16 Example of ratios Ratio Number of primary turns Number of secondary turns /1 1 : 2 : 4 1) /1 2 : 4 : 8 1) /1 1 : 2 2) /1 1 : 2 1) /1 3 : 6 1) /1 1 : 6 1) /1 1 : 4 : 8 1) 800 1) : Standard primary reconnection (double or triple ratio) max. Icth = 3000 A (on highest ratio) 2) : High current reconnection (only double ratio) max. Icth = 4500 A (on highest ratio standard head) max. Icth = 5000 A (on highest ratio G head) / page 16 /
17 Secondary tapping /1 P1 P2 1S1 1S2 1S3 2S1 2S2 2S3 3S1 3S2 3S3 4S1 4S2 4S3 5S1 5S2 5S3 Number of primary turns: 1 Number of secondary turns: / page 17 /
18 Unbalance CT for MSCDN application MSCDN : Mechanical Switched Capacitor with Damping Network Current ratio 1:1 A / 5:5 A / 10:1 A or similar Usually 1 or 2 Protection Cores (ex: 10 VA 5P10) Ratio Number of primary turns Number of secondary turns 1/ / page 18 /
19 Special test: Internal arc Some Markets require Special Test «Internal arc» e.g. France, Canada, Poland, Internal arc is the failure of high voltage insulation inside the instrument transformer short-circuit to ground Arc is vaporizing the oil High and fast increase of internal pressure of IT Housing explodes -> high accident risk for persons in substation Test shall proof a «controlled» bursting of housing without ejection of parts / page 19 /
20 Classification IEC describes internal arc test as special test Possible with oil insulated IT and tested by Pfiffner Possible with oil insulated IT, but not tested by Pfiffner NOT possible with oil insulated IT / page 20 /
21 Special test: Internal arc In general the defined currents are too high, because phase to ground currents are lower than phase to phase currents which define I th Small currents < 20 ka with standard design possible For currents >= 20 karms expensive design with rupture discs and enforced housings necessary Is the customer willing to pay extra for this design? Development for VT stopped due to high cost pressure from Market Don t make active marketing with internal arc test. / page 21 /
22 Internal arc test on JOF 245 G / page 22 /
23 Executed internal arc tests Pfiffner Tests available for JOF (small head) JOF GXP head: EOF : EJOF : 12 ka / 20 ka 31.5 / 40 ka 12 ka 12 ka Tests are Expensive: Laboratory cost and Instr. Transformer which will be destroyed rare number of laboratories which perform internal arc test. IEC standard lets a lot of room for interpretation of test execution Pfiffner proposal: 1. Dielectric routine test on test object must be fulfilled, 2. install arc initiation (wire / nail) 3. Execute internal arc test / page 23 /
24 Conclusion The important developments take place with non-conventional technologies Oil ITs are mainly adapted to requirements of new markets, e.g. RTE France, NG England Some special customer adaptions are opposing standardisation for cost reduction / page 24 /
25 Questions / discussion Thank you for your attention / page 25 /
Central Power Research Institute, Medipally PO, Uppal, Hyderabad, Telangana. Discipline Electrical Testing Issue Date
Last Amended on 31.07.2015 Page 1 of 11 I. SWITCHGEAR EQUIPMENT 1. High Voltage switchgear & control gear and AB switches Ratings upto 1200 kv system Switching Impulse Voltage (Dry & Wet) Power Frequency
More informationPlug and Operate Transformer Technology
Plug and Operate Transformer Technology Deepal Shah PFISTERER deepal.shah@pfisterer.com by and Andre Goessler PFISTERER andre.goessler@pfisterer.com 1 THE POWER CONNECTION We have always worked closely
More informationABB Digital medium-voltage switchgear
NAMIBIA AMEU/AEDU MARCH 2018 ABB Digital medium-voltage switchgear Barry Addinall UniGear Digital Contents 1. Digital switchgear 2. Complexity of Distribution networks 3. New technologies using digital
More informationInstrument Current Transformers
Catalog No. 4B Instrument Current Transformers 600 volt - 15Kv Reliability and Quick Results Reliability and quick response are the reasons you should select a Piedmont Current Transformer or have us build
More informationfor the protection of gas-insulated metal-enclosed switchgear against lightning and switching overvoltages
GAS-INSULATED METAL-ENCLOSED SURGE ARRESTERS (GIS-ARRESTERS) for the protection of gas-insulated metal-enclosed switchgear against lightning and switching overvoltages GIS-Arresters from Siemens GIS arresters
More informationEquipment Strategy for Voltage Transformers Strategy
Equipment Strategy for Voltage Transformers Strategy Current version: 19/06/2018 EXTERNAL USE Page 1 of 6 Table of contents 1. Introduction... 3 1.1 Purpose... 3 1.2 Scope... 3 1.3 References... 3 1.4
More informationPressure switch, Differential pressure switch RT
Data sheet switch, Differential switch RT An RT switch contains a operated single-pole changeover contact, the position of which depends on the in the inlet connection and the set scale value. The RT series
More informationLimit switches for Dial Thermometers and Pressure gauges
JJ Direct limit switches JJ Indirect limit switches JJ Multifunction relays Limit switches for Dial Thermometers and Pressure gauges DS_Limit_switches 08/2015 349 Limit switches Limit switches are optional
More informationElastimold Molded Vacuum Recloser - MVR
Subject: Elastimold Recloser Technical Specification Date: 4/24/12 File: MVR-RS-0412 Page: 1 of 6 1.0 SCOPE Elastimold Molded Vacuum Recloser - MVR 1.1 This specification covers electrical and mechanical
More informationPressure switch, Differential pressure switch RT
Data sheet switch, Differential switch RT An RT switch contains a operated single-pole changeover contact, the position of which depends on the in the inlet connection and the set scale value. The RT series
More informationINSTRUMENT TRANSFORMERS
Low-Voltage and Medium-Voltage INSTRUMENT TRANSFORMERS Including ERCT Products Instrument Transformer Manufacturer ISO-9001:2015 certified German technology transferred Over 40 years of manufacturing and
More informationAnnexure-1 (CC no )
Annexure-1 (CC no. 77627) TECHNICAL SPECIFICATIONS OF EXISTING LIGHTNING ARRESTORS S. No. Description Parameter 1. Type Station class heavy duty zinc oxide gapless 2. Applicable standard IEC-60099-4 /
More informationTitle System Substation Commissioning Tests. Reference Number PCP 07 - (RIC Standard: EP SP)
Discipline Engineering Standard - NSW Category Electrical Title s Reference Number PCP 07 - (RIC Standard: EP 99 00 00 02 SP) Document Control Status Date Prepared Reviewed Endorsed Approved Mar 05 Standards
More informationPower Transmission Division Link between power generation and distribution
Power Transmission Division Link between power generation and distribution Seite 4 High Voltage Substations Schemes, Devices and Types of AIS Installation Content Link between power generation and distribution
More informationCFD, IEC STANDARDS AND TESTING LABORATORIES: JOINING THE PIECES FOR HIGHER QUALITY HV EQUIPMENT. Cognitor Consultancy, Research and Training Ltd.
CFD, IEC STANDARDS AND TESTING LABORATORIES: JOINING THE PIECES FOR HIGHER QUALITY HV EQUIPMENT. Author name: Sergio Feitoza Costa Affiliation: Cognitor Consultancy, Research and Training Ltd. Summary:
More informationSelling PFIFFNER in Mexico. Genaro Pérez
Selling PFIFFNER in Mexico. Genaro Pérez Contents Country & Market Overview México. PFIFFNER Value proposition. Requirements for success Conclusions. www.pfiffner-group.com / page 2 / 12.06.2017 Contents
More informationRapier GX Gas Enclosed Load Break Switch and Sectionaliser up to 38kV with automation or remote control options ENGINEERING BRILLIANT SOLUTIONS
Rapier GX Gas Enclosed Load Break Switch and Sectionaliser up to 38kV with automation or remote control options ENGINEERING BRILLIANT SOLUTIONS RAPIER GX Gas Enclosed Switch Our new RAPIER GX, pole-mounted
More informationPOWER GRIDS. We are bridging the gap. Enabling Digital Substations.
POWER GRIDS We are bridging the gap. Enabling Digital s. 2 A B B D i g i ta l S u b s tat i o n s ABB s Digital provides customers in the utility sector with unmatched control and efficiency. The digital
More informationBenefits, offering and references
DOC ID: 9AKK107045A9180 DISTRIBUTION SOLUTIONS Digital medium-voltage switchgear Benefits, offering and references Contents Digital switchgear for medium-voltage applications Digital switchgear definition
More informationThermostat KP. Data sheet. The KP Thermostats are single-pole, doublethrow (SPDT) temperature-operated electric switches.
Data sheet Thermostat KP The KP Thermostats are single-pole, doublethrow (SPDT) temperature-operated electric switches. They can be connected directly to a single-phase AC motor of up to approx. 2 kw or
More informationSurge Suppressor Capacitors, Single Phase Units, All-Film Technology up to 36 kv
Surge Suppressor Capacitors, Single Phase Units, All-Film Technology up to 36 kv FEATURES Latest technology Dielectric liquid biodegradable High quality materials Damping resistor from 10 to 50 APPLICATIONS
More informationSession Five: IEC61850 Based Process Bus Protection Solution for Remote Located Power Transformers
Session Five: IEC61850 Based Process Bus Protection Solution for Remote Located Power 1. Abstract Dinesh Mithanthaya Design Manager, Horizon Power Higher capacity substation power transformers ( 5MVA),are
More informationDetails of the Han-Terminal block connector Han D AV Han D AV Distributor Han E AV Han ES AV
Contents -Terminal Block Connectors Page Details of the -Terminal block connector........................ 08.02 D................................................... 08.10 D Distributor...........................................
More informationEach VariSTAR Type AZU arrester must pass the following production tests: 100% Physical Inspection 100% Leakage Current Test 100% RIV Test
Surge Arresters VariSTAR Type AZU Heavy-duty Distribution Class Under-oil MOV Arrester Electrical Apparatus 235-64 GENERAL The Cooper Power Systems VariSTAR Type AZU under-oil MOV arrester is designed
More informationPowerLogic High Density Metering System 1-Meter Enclosure
PowerLogic High Density Metering System 1-Meter Enclosure Installation Guide 63230-508-211A1 Safety information PowerLogic High Density Metering System 1-Meter Enclosure Important information Read these
More informationMESP TECHNICAL SPECIFICATION FOR 22 kv METAL ENCLOSED SWITCHGEAR
Engineering Specification Electrical Networks TECHNICAL SPECIFICATION FOR 22 kv Version: 2 Issued: 19 th December 2016 Owner: Chief Engineer Approved By: Andrew Russack Head of Engineering - Electrical
More informationRapidus Power Factor Controller
Rapidus Power Factor Controller Moduler design No connector cables No fixing screws State of the art technology Easy mounting on panels connection to system Dynamic Capacitor Monitoring DCM is a supreme
More informationSolid insulated vacuum recloser for power distribution system thru 15kV, 27kV, 38kV Version 3.3
www.entecene.co.kr Solid insulated vacuum recloser for power distribution system thru 15kV, 27kV, 38kV Version 3.3 General features We, ENTEC introduce a Solid Insulated Vacuum Recloser encapsulated with
More informationELG4125: System Protection
ELG4125: System Protection System Protection Any power system is prone to 'faults', (also called short-circuits), which occur mostly as a result of insulation failure and sometimes due to external causes.
More information3a. IEM Indoor Metal Clad Medium Voltage Switchgear 25KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.
3a. IEM Indoor Metal Clad Medium Voltage Switchgear 25KV 16346-1 3a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std. Relays) Part 1 General 1.1 CONDITIONS AND REQUIREMENTS: A. Refer to
More informationMeter Enclosure and Equipment Standards
Meter Enclosure and Equipment Standards (a) (b) General Requirements: CITY OF OCALA UTILITY SERVICES METER ENCLOSURE AND EQUIPMENT STANDARDS: (1) To avoid the costs associated with having to replace unacceptable
More informationENhanced TEChnology. Solid insulated vacuum recloser for power distrbution system thru 15kV, 27kV, 38kV V 3.1
ENhanced TEChnology www.entecene.co.kr Solid insulated vacuum recloser for power distrbution system thru 15kV, 27kV, 38kV V 3.1 General features We, ENTEC introduce a Solid Insulated Vacuum Recloser encapsulated
More informationType SDR reclosers plus controllers and type B-2 recloser bypass switch assembly usa.siemens.com/mediumvoltage
Overhead solutions Type SDR reclosers plus controllers and type B-2 recloser bypass switch assembly usa.siemens.com/mediumvoltage Overhead switching products Brochure Your outdoor overhead distribution
More informationPower supply unit NG3-16ib
Ordering Data Designation Type Item no. Power supply unit NG3-16ib (42 V AC / ) 371 008 31 AX Power supply unit NG3-16ib (230 V AC / ) 371 008 32 AX Power supply unit NG3-16ib (100 V AC / ) 371 008 34
More informationDigital Substation Overview of Technology, Industry
Digital Substation Overview of Technology, Industry Trends and Standardization Efforts 4th International Scientific & Technical Conference Actual Trends in Development of Power System Protection and Automation
More informationHigh Voltage AC Power Capacitors 3-Phase Capacitor Banks
High Voltage AC Power Capacitors 3-Phase Capacitor Banks FEATURES Latest technology High quality materials Low losses design Dielectric liquid biodegradable APPLICATIONS Power factor correction Harmonic
More informationPrepared by: Yvon Filion eng. TransÉnergie, a division of Hydro-Québec
Prepared by: Yvon Filion eng. TransÉnergie, 1 1- Introduction 2- Technical aspects 3- Benefits for the circuit breaker 4- Benefits for the Capacitor units 5- Benefits for the system (power quality issues)
More informationPower supply CP-C 24/5.0
2CDC 271 064 F0004 Features Supply voltage ranges: 85-264 V AC, 100-350 V DC Output voltage adjustable from 22-28 V DC, default setting 24 V DC 0,5 % 5 A output current Open-circuit, overload and continous
More informationDATA SHEET Selectable AC transducer, TAS-331DG
DATA SHEET Selectable AC transducer, TAS-331DG Measures power or reactive power on 3-phase AC networks Class 0.5 (IEC-688) measurement Supply and measuring voltage up to 690 V Easy configuration via PC
More informationHigh Voltage AC Power Capacitors 1-Phase Units
High Voltage AC Power Capacitors 1-Phase Units FEATURES Latest technology High quality materials Low losses design Dielectric liquid biodegradable APPLICATIONS Power factor correction Harmonic filtering
More informationRE7YA12BU time delay relay for star-delta starter s - 24 V AC DC - 2OC
Characteristics time delay relay for star-delta starter - 0.05..1 s - 24 V AC DC - 2OC Main Range of product Product or component type Contacts type and composition Component name Time delay type Time
More informationMotor Surge Suppressors and Cable Considerations
Motor Surge Suppressors and Cable Considerations Understanding the growing need for motor surge protection in SA Arveen Gobind Pragma Condition Monitoring (Martec) Agenda Introduction Network Motor Surge
More informationRemote Real-Time Measurements of Voltage, Current and Energy
Remote Real-Time Measurements of Voltage, Current and Energy Chris Yakymyshyn Pam Hamilton Michael Brubaker yakymyshyn@fieldmetricsinc.com 727-319-0299 Slide 1 Outline Introduction FieldMetrics (FMI) Products
More informationHID. GE Consumer & Industrial Multilin. High Impedance Differential Module Instruction manual GEK Copyright 2005 GE Multilin
g GE Consumer & Industrial Multilin HID High Impedance Differential Module Instruction manual GEK-113064 Copyright 2005 GE Multilin GE Multilin 215 Anderson Avenue L6E 1B3 Markham, ON -CANADA T (905) 294
More informationSCXI HIGH-VOLTAGE 8 4 MATRIX TERMINAL BLOCK
INSTALLATION GUIDE SCXI -1332 HIGH-VOLTAGE 8 4 MATRIX TERMINAL BLOCK Introduction This guide describes how to install and use the SCXI-1332 terminal block with your SCXI-1127 module. The SCXI-1332 terminal
More informationSMS 4 / SMS 5 safety mat Product information
SMS 4 / SMS 5 safety mat Product information SMS 4 / SMS 5 safety mats Safety mats are used for the protection of man on machinery and plants with hazardous movements. Typical fields of application are,
More informationIt is the job of the protection system equipment to recognize and remove the fault.
Protection 1 (read section 13.0 of text) 1.0 Introduction Faults do not occur that frequently 1/year/100 miles of transmission is typical. Distribution systems may see more than this. However, when they
More informationIdentify and understand the operation of common bus. After this presentation you will be able to: Identify common bus arrangements
Introduction to Bus Protection By Matt Horvath, P.E. November 6, 2018 Electrical Buses Physical and Electrical Junction A bus is a critical element of a power system, as it is the point of convergence
More informationOperating Instructions for Vibrating Level Switches. Model: NVI
Operating Instructions for Vibrating Level Switches Model: NVI 1. Contents 1. Contents... 2 2. Note... 3 3. Instrument Inspection... 3 4. Regulation Use... 3 5. Operating Principle... 4 6. Mechanical Connection...
More informationRE7RB13MW adjustable off-delay timing relay s V AC DC - 2OC
Characteristics adjustable off-delay timing relay - 0.05..1 s - 240 V AC DC - 2OC Main Range of product Product or component type Contacts type and composition Component name Time delay type Time delay
More informationDEIF A/S. MIC Multi-instrument G. Data sheet. Features. Accuracy. Measurements. Installation. Intelligent. Display. Communication DEIF A/S
Multi-instrument 4921210107G Features Measurements All 3-phase AC measurements True RMS Replaces analogue meters Intelligent Suitable for all 3-phase network topologies Replaces transducers Accuracy U,
More information10 Mb/s Single Twisted Pair Ethernet Process Industry Requirements Steffen Graber Pepperl+Fuchs
10 Mb/s Single Twisted Pair Ethernet Process Industry Requirements Steffen Graber Pepperl+Fuchs IEEE802.3 10 Mb/s Single Twisted Pair Ethernet Study Group 9/8/2016 1 Overview Introduction Current bus Infrastructure
More informationSENSOR TECHNOLOGY IN A MEDIUM VOLTAGE SWITCHGEAR FOR THE US MARKET APPLICATIONS
SENSOR TECHNOLOGY IN A MEDIUM VOLTAGE SWITCHGEAR FOR THE US MARKET APPLICATIONS Predrag Milovac Radek Javora Veselin Skendzic IEM USA ABB Czech Republic SEL USA predrag.milovac@iemfg.com radek.javora@cz.abb.com
More informationKMP A3. Air Insulated Medium Voltage Switchgear Powerful. Safe. Highly Available
KMP A3 Air Insulated Medium Voltage Switchgear Powerful. Safe. Highly Available High power switchgear systems For primary applications The name MediPower represents powerful medium voltage energy distribution
More informationRole of Surge Arrestors in Electrical Power Systems
International Journal of Advances in Electrical and Electronics Engineering 1 Available online at www.ijaeee.com & www.sestindia.org/volume-ijaeee/ ISSN: 2319-1112 Role of Surge Arrestors in Electrical
More informationUser manual Technical parameters
User manual Technical parameters thyro System english Thyristor for reactive current compensation 2 KBR GmbH Subject to technical changes Contents Intended use... 4 Safety Notes... 6 Application range...
More informationRE7YA12BU. Main. Contacts type and composition Component name Time delay type. 24 V AC/DC at 50/60 Hz V AC/DCat 50/60 Hz
Product datasheet Characteristics RE7YA12BU Main Range of product Product or component type Contacts type and composition Component name Time delay type Time delay range Zelio Time Industrial timing relay
More informationDRAFT. Application Note: Modbus/RS485 Wiring for Conext Core XC Series Inverters. 1.0 Introduction DANGER. 1.1 Related Documents
Application Note: Modbus/RS485 Wiring for Conext Core XC Series Inverters AP-XC-025 Revision B 1.0 Introduction DANGER RISK OF ELECTRIC SHOCK, EXPLOSION, ARC FLASH, AND FIRE This Application Note is in
More informationMACX MCR-EX-SD LP(-SP)
Intrinsically safe solenoid driver for Group IIC gases, loop-powered, current limit 48 ma INTERFACE Data sheet 103468_en_01 PHOENIX CONTACT - 08/2008 1 Description The solenoid driver MACX MCR-EX-SD-24-48-LP(-SP)
More informationMIC-2 Multi-instrument DATA SHEET
Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional) Profibus DP (optional) I/O modules
More informationFundamentals of Circuit Breaker Maintenance. AVO Training Institute, Inc. 2018
Fundamentals of Circuit Breaker Maintenance 1 AVO Training Institute, Inc. 2018 Moderator n Ron Spataro AVO Training Institute Marketing Manager 2 Q&A n Send us your questions and comments during the presentation
More informationPFC Mini TM Power Factor Corrected AC-DC Switchers
21 PFC Mini TM Power Factor Corrected AC-DC Switchers Overview Technical Description The PFC Mini is an extremely low profile switching power supply that combines the advantages of power factor correction,
More informationPHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.
Primary switched power supply, 3-phase, output current: 40 A INTERFACE Data Sheet 102782_01_en PHOENIX CONTACT - 06/2007 Description TRIO POWER is the rail mountable 24 V power supply unit with basic functions.
More informationE-STOP relays, safety gate monitors
Gertebild ][Bildunterschrift Safety relay for monitoring E-STOP pushbuttons and safety gates. Approvals Unit features Gertemerkmale Relay outputs: 2 safety contacts (N/O), instantaneous 1 semiconductor
More informationDesign, Control and Application of Modular Multilevel Converters for HVDC Transmission Systems by Kamran Sharifabadi, Lennart Harnefors, Hans-Peter
1 Design, Control and Application of Modular Multilevel Converters for HVDC Transmission Systems by Kamran Sharifabadi, Lennart Harnefors, Hans-Peter Nee, Staffan Norrga, Remus Teodorescu ISBN-10: 1118851560
More informationRM4LA32M liquid level control relay RM4-L V AC
Characteristics liquid level control relay RM4-L - 220..240 V AC Complementary [Un] rated nominal voltage Operating voltage tolerance Width Output contacts Maximum electrode voltage Maximum electrode current
More informationPower Supply, Primary Switch Mode for Universal Use QUINT-PS AC/48DC/5
Power Supply, Primary Switch Mode for Universal Use -PS-100-240AC/48/5 POWER provides: Preventive function monitoring through professional signaling Global use due to a wide range input A high level of
More informationOn the other side, performing tests is an expensive task, demanding
APPLICATION NOTE CIRCUIT BREAKER TEST WITH BOTH SIDES CONNECTED TO PRACTICAL CASE HISTORY : ISA CBA 1000 & CBA 2000 with BSG 1000 1. THE NECESSITY OF OPERATING SAFELY The HV circuit breaker is the most
More informationHD22 and HD30 Service Parts
HD and HD0 Service Parts This is the list of service parts and wiring diagrams for all versions of these two hotel dispensers. Pay close attention to the voltage and/or cycles to be sure of ordering the
More informationVoltage Regulated Distribution Transformer
Voltage Regulated Distribution Transformer SmartActiveTransformer The economical alternative The economical alternative to grid expansion optimal grid capacity utilisation: the integration of increasingly
More informationQUINT-PS-3x AC/24DC/10
3-Phase Primary-Switched Power Supply Unit INTERFACE Data Sheet PHOENIX CONTACT - 12/2005 Description QUINT POWER devices are 60...960 W power supply units for universal use. This is ensured by the wide-range
More informationGUIDELINES FOR THE CLASSIFICATION OF GRID DISTURBANCES ABOVE 100 kv
GUIDELINES FOR THE CLASSIFICATION OF GRID DISTURBANCES ABOVE 100 kv 13.04.2017 1 INTRODUCTION... 4 2 PURPOSE OF THE GUIDELINES... 4 3 SCOPE AND LIMITATIONS OF THE STATISTICS... 5 4 DEFINITIONS... 6 4.1
More informationOur Power & Control line of Business offers solutions that safely distribute power to your home or business. Our product range includes Low/Medium
Our Power & Control line of Business offers solutions that safely distribute power to your home or business. Our product range includes Low/Medium Voltage Panels and Enclosures designed and built with
More informationContact expander modules
Gertebild ][Bildunterschrift Kontakterweiterungen Contact expansion module for increasing the number of available contacts Approvals Zulassungen Unit features Gertemerkmale Positive-guided relay outputs:
More informationRedundancy unit CP-A RU
2CDC 271 010 F0t06 Features Decoupling of CP power supply units with 2 inputs, each up to 20 A per input / channel Output up to 40 A True redundancy by 100 % decoupling of two parallel connected power
More informationMIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET
& DIN, Multi-instrument DATA SHEET Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional)
More informationUL TEST REPORT AND PROCEDURE
Issue Date: 2012-02-09 Page 1 of 13 Report Reference # E116994-A76-UL UL TEST REPORT AND PROCEDURE Standard: ANSI/AAMI ES60601-1:2005, 3rd ed. (Medical Electrical Equipment - Part 1: General Requirements
More informationSLIMCON-6 24V DC POWERED ISOLATING SIGNAL CONVERTER
SLIMCON-6 24V DC POWERED ISOLATING SIGNAL CONVERTER Whilst every effort has been taken to ensure the accuracy of this document, we accept no responsibility for damage, injury, loss or expense resulting
More informationPositive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous
Gertebild Bildunterschrift Two-hand control device for safety circuits Approvals Zulassungen Unit features Gertemerkmale Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary
More informationMIC-2 MKII, Multi-instrument DATA SHEET
MIC-2 MKII, Multi-instrument DATA SHEET Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional)
More informationDELTA kv Automated Insulation Power Factor Test Set with PowerDB OnBoard DELTA kv Automated Insulation Power Factor Test Set
DELTA3000 10 kv Automated Insulation Power Factor Test Set with PowerDB OnBoard Integrated PowerDB software package allows for automated control without the use of a laptop Rugged, portable unit for field/shop
More informationSafety wherever needed
Safety wherever needed Low Voltage Surge Arrestors Uninsulated version Isolated version Rope-throwing-off-function MM: Bild angeben Content 280 Technical data see page 281 System The Low Voltage Surge
More informationDigital substations. Introduction, benefits, offerings
Digital substations Introduction, benefits, offerings Outline What is a digital substation? Benefits of digital substations ABB offering for digital substations Substation evolution June 26, 2017 Slide
More informationIndication and Adjustment Product Information VEGADIS 61. Level Switching Pressure
Indication and Adjustment Product Information VEGADIS 61 Level Switching Pressure 2 VEGADIS 61 Contents Contents 1 Product description...4 1.1 Configuration... 4 1.2 Principle of operation... 4 1.3 Adjustment...
More informationMagnetic and Hydraulic-Magnetic Circuit Breaker 8340-F...
Description Single and multipole magnetic circuit breakers with trip-free mechanism and toggle actuation. A choice of fast magnetic only or hydraulically delayed switching characteristics (S-type MO or
More informationEvaluation of different solutions of faulted phase earthing technique for an earth fault current limitation
24th International Conference & Exhibition on Electricity Distribution (CIRED) 12-15 June 2017 Session 3: Operation, control and protection Evaluation of different solutions of faulted phase earthing technique
More informationCoolback II way Active Mono Amplifier
Coolback II 600 3-way Active Mono Amplifier Features 3-way Mono Digital Crossover 3 High performance Class AB amplifiers Sophisticated Power Supply Automatically On/Off via signal sensing Very Quick Soft
More informationMagnetic and Hydraulic-Magnetic Circuit Breaker 8340-F...
Magnetic and Hydraulic-Magnetic Circuit Breaker 830-F... Description Single and multipole magnetic circuit breakers with trip-free mechanism and toggle actuation. A choice of fast magnetic only or hydraulically
More informationSAFETY PRESSURE MATS GENERAL PRODUCT FEATURES
SAFETY PRESSURE MATS 9 GENERAL PRODUCT FEATURES SCHMERSAL s Series SMS Safety Pressure Mats feature a 100% active area, low actuating force, rugged cable termination, durable unibody construction cable
More informationICF-1150 Series Quick Installation Guide
ICF-1150 Series Quick Installation Guide Fifth Edition, July 2015 2015 Moxa Inc. All rights reserved. P/N: 1802011500014 1802011500014 Overview Introduction ICF-1150 series fiber converters have a multi-interface
More informationFigure 1. Storm Trapper H. E. arrester, external mount. Figure 2. Storm Trapper H.E. arrester, metal enclosed. use in Storm Trapper H.E. arresters.
Surge Arresters Storm Trapper H.E. (High Energy) Low-Voltage Distribution-class MoV Surge Arrester Electrical Apparatus 235-16 GEnErAL Cooper Power Systems Storm Trapper H.E. (High Energy), lowvoltage
More informationRE22R2QTMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O
Characteristics StarDelta Timing Relay 0.05s 300h 24 240V AC/DC 2C/O Main Range of product Product or component type Discrete output type Device short name Nominal output current Zelio Time Modular timing
More informationpower pazifik MV Switchgear Secondary Distribution Networks Fully Gas-Insulated Modular and Compact (RMU) System Up to 36 kv
Manufactured by: MV Switchgear Secondary Distribution Networks Fully Gas-Insulated Modular and Compact (RMU) System Up to 36 kv BO-CGM.3/3 SMART RMU Switchgear in Metro Manila Protection and safety for
More informationCertification Process Household and Similar Equipment
Certification Process Household and Similar Equipment Ordinance No. 371, of December 29, 2009 Objective: Evaluation of household and similar appliances, with a focus on security requirements in order to
More informationLVAC DW-Type Filter Capacitors
LVAC DW-Type Filter Capacitors FEATURES High output and high over-current design Welded rectangular capacitors with or 6 terminals Overpressure monitoring device APPLICATIONS Automatic and individual fixed
More informationTU531, TU532 Terminal Unit
Ordering Data DATA SHEET TU531, TU532 Terminal Unit 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 217 200 R0001 1SAP 217 000 R0001 1SAP 417 000 R0001 TU531, terminal unit, 230 VAC,
More informationFEATURES DESCRIPTION
JUNCTION BOXES FEATURES Allows easy and safe device connections to the fieldbus (Fo u n d at i o n fieldbus TM, PROFIBUS) HART and even for standard instrumentation wiring 4-20 ma; Ideal for coupling sensors,
More informationMTeC - EPT202 Digital thermometer Messko
www.messko.de MTeC - EPT202 Digital thermometer Messko MTeC -EPT202 the all-roundermto ST160 und MTO STF 160 The main functions such as Power, Alarm, Trip, Error and the operating status of the individual
More informationNU-LEC. Loop Automation. Reclosers & Sectionalizers
NU-LEC Loop Automation Reclosers & Sectionalizers 1 NU-LEC LLC NU-LEC LLC is a wholly unit of NU-LEC Industries, Pty, Ltd. Sales and service center for United States, Canada, and the Caribbean. Warehouse
More informationMONITORING ABSTRACT KEYWORDS. TRANSFORMERS MAGAZINE Special Edition: Bushings, 2017
MONITORING The difference between safe and reliable on-line bushing monitoring and false alarms often lays in the quality of the sensor design and the installation procedure ABSTRACT On-line monitoring