SY210NT V5. Networking Muti-Doors Controller Installation Manual V0110

Size: px
Start display at page:

Download "SY210NT V5. Networking Muti-Doors Controller Installation Manual V0110"

Transcription

1 SY210NT V5 Networking Muti-s Installation Manual V0110 WARNING: This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer. The entire manual should be carefully read. SYRIS Technology Corp. 21F-2, NO.12, Sec1, Taijunggang Rd, Taichung, Taiwan (403) Tel: Fax:

2 SECTION 1: INTRODUCTION TO SY210NT V PRODUCT OVERVIEW ABOUT THIS MANUAL New in this Version Fast Setting Index Sheet and Card Record Sheet FEATURES SPECIFICATIONS...4 SECTION 2: SY210NT WIRE & QUICK INSTALLING REQUIRED EQUIPMT SELECTING A MOUNTING LOCATION TYPICAL MOUNTING DIAGRAM INSTALLING SY210NT INSTALLING THE READER WIRING DIAGRAM5 2.6 CONNECTING DOOR LOCK WIRING DIAGRAM CONNECTING BUTTON TO DOOR OP CONNECTING THE DOOR DETECTION CONNECTING POWER SUPPLY...5 SECTION 3: SY210NT V5 SETTING INTRODUCTION SETTING MU LOGIN SETTING MU LOGOUT SHOW VERSION SY210NT FACTORY DEFAULTS...6 SECTION 4: SY210NT V5 SETTINGS SYSTEM FUNCTIONS Functions Module System Utility CARD MANAGEMT Add Card Edit Card Delete Card Show Card All Card APB Setting FINGERPRINT MANAGEMT Add Fingerprint Delete Fingerprint Delete All Fingerprint... 7 SECTION 5: SET UP SY210NT V5 STEP BY STEP CONTROLLER FUNCTION Set ID Same Card Time Invalid Lock Baud Rate Setting DI Setting Elevator Mode Set Max Card READER MODULE SETTING Module Auto Detect Reader Module ID Setting MDWIE-2 ID Setting DOOR FUNCTION SETTING Relay Push Button APB Setting MASTER CARD FUNCTION SETTING PIN Setting Add Card Delete Card SYSTEM UTILITY Date Setting Time Setting System Reboot Data Backup / Restore System Initial CARD MANAGEMT Add Card Add Card By Serial Add Card By No Edit Card Card Condition Setting (Valid / Invalid) Card PIN Setting Card APB Setting

3 Single Card Delete Delete All Card Cards Browse All Card APB Setting FINGERPRINT MANAGEMT Add Fingerprint Delete Fingerprint Delete All Fingerprint RESETTING THE SY210NT UNIT TO FACTORY DEFAULTS...10 APPDIX 1:QUICK REFERCE PROGRAMMING TABLE 11 APPDIX 2:PROGRAMMING WORKSHEET...12 APPDIX 3:CARD INFORMATION RECORD SHEET13 APPDIX 4: SY210NT V5 CARD CAPACITY AND I/O DATA LIST 14 APPDIX 5:USING THE SY210NT SYSTEM...15 Q1: How to setting reader ID? What Reader ID and are relate?...15 Q2: How to add the card?...16 Q3: How to setting the push button from controller? 16 Q4: How to Connect HID Readers of Wiegand interface with?...17 Q5: How to use MDDIDO Module Connecting the Exit Detector or Exit Button?...18 APPDIX 6: GERAL WIRING DIAGRAM

4 Section 1: Introduction to SY210NT V5 MDNET-1 Module The functions are same as MDNET Product Overview 4. Printer Module Networking Multi-s can control 4 doors, link 8 card readers (4 IN, 4 can connect to the following printers directly or reports printing via OUT), use 63,000 cards and 210,000 I/O data record at most. (Reference printer module. appendix 4) 1. Impact Printers 2. Ink Jet Printer 3. Laser Printers SY210NT V5 Network Multi-s provides perfect functions and stable & reliable quality. * The controller can supply 63,000 people to use at most. * Single controller can manage 4 doors In/Out at the same time. * Regional Anti-Pass Back (APB) function will be activated without PC on-line. * The local APB will be activated in LAN. * The motherboard produced by the SMD technology. The quality is stable and reliable. Easy Setting All setting can be set by using controller keypad and LCD monitor(16x2 Char). You can make choice of purchase of expansion module that divides into two types: internal and external. Internal module of controller include: 1. MDNET-2 Ethernet Converter Ethernet Communication Converter used to convert RS485 series signal Fast Setting Index Sheet and Card Record Sheet into TCP/IP package. According to different network application types, the User can find out a setting location by referring the Quick Reference Programming module provides two types:server mode & Client mode. Table, appendix 1. The module will wait for the signal from network and it will send decode User can print and record Card Information by using appendix 3.. signal to HOST CPU through series communication port under Server mode. The module will re-package the signal and resend on network while MDDIDO Module divides MDDIDO-16 channel (16 voltage free input, 16 relay output) and MDDIDO-1S 2 channel (4 voltage free input, 2 relay output). System extendibility:user can use MIDDO module expansion of system when first program insufficient for user need; MDDIDO Module is easy to expansion; e.g. Add controller, Readers or DIDO Modules etc. 3. MDWIE-1 (Wigand Module install inside of the ) MDWIE-1 Wigand Module has 2 S/N. Each number represents a channel, is similar to RS485 Reader; First W26Reader use first Serial NO. Reader ID setting( ID=1, Firs door; ID=2;Second door..). When expand the MDWIE-1 Module to transform the RS485 interface into the Wiegand interface, user can connect with each kind of devices of Wiegand interface About this Manual This Installation Manual provides installation and setting instructions for SY210NT V5. Please read this manual carefully before installing or setting the SY210NT New in this Version The subject matters of the manual are focus on update of SY210NT V5: 1.Increase the number of user:the number of user can up to 63,000. I/O records can up to 21,000. (Reference appendix 4) 2.The time of door open by hand is longer:the time can be set as 9999 seconds or above. 3.Backup SD Card:The types of backup are Manual /Automatic. The backup / restore set can up to 10 sets. 4. Invalid password entering event handle:user can set times or lock time while error password input (1~999 sec). 1.3 Features received reply from the CPU HOST. And then the command cycle will be 1. Internal extension Module optional: done. User can add MDNET-2 network module to expand network function interface. (a) (b) 10/100M Ethernet Converter(MDNET-2). 4CH Wigand Signal Input Module(MDWIE-2). (c) SD Card module (MDSD-2 applies SD Card whose memory size of 2. MDPOE-1 Ethernet Power supplier module (Power over 256MB 512MB 1GB). Ethernet) (d) POE Power over Ethernet Module (MDPOE-1,Client). Power over Ethernet is called PoE that is the technology about power 2. The controller can be run with the software: SYW95A-V V2 V3 SYW95A supply. PoE can transmit electrical power over standard twisted-pair cable in -V2-NET and SY-SOFT-95A. an Ethernet network. We can supply power from HUB by using this 3. User can adjust the number of cards and record capacity of I/O data according to technology without connect other power source. need. 3. MDWIE-2 (Wiegand Signal Input Module) After installing 4 CH Wigand signal input module (MDWIE-2), user can connect four readers that include reader fingerprint etc. All devices as mention have Wiegand interface. 4. Promote number of User/Card and I/O data record:if using the new version of SY-SOFT-95A, the card/user capacity can increase to 21,000; High-capacity Device can promote number of User/Card to 63,000 and promote I/O data records to 210,000 at most. The whole speed of CPU promotes to 100 MIPS. (Reference 4. SD Card appendix 4). User can choose the SD CARD module to increase IO records or backup 5. After installing SD Card Module and SD Card, user can backup all data from the the controller data. The slot of SD CARD(MDSD-2) can compatible with the capacity of SD CARD include 256MB 512MB and 1GB. External Device of : controller. 6. Fast update firmware:support to update the firmware on-line through RS485 or Ethernet. 1. Reader 7. While Ethernet network module is added, the communication styles to HOST-PC are polling and auto-transmission. Both of the polling and auto-transmission can The Reader includes SYRDS1 Proximity Card Reader SYRDS5 Proximity run at the same time. The system provides not only efficient transmission but also Card Reader SYRDL5 Mini Proximity Reader SYRDT5 LCD Proximity Card Reader and SYRDF5/F6 Fingerprint Reader. System extendibility:link 8 readers at most. The types of Reader divide into 125K (EM) 13.56M (Mifare). response event immediately. While more and more doors in system, the excellent functions will be presented. 8. The system will send commands to related controller and modules to active fire control and fire alarm automatically through Ethernet converter. The functions also 2. MDDIDO Module can be handled through client PC. 1.4 Specifications Number of Cards 3,500 ~ 63,000; Number of Readers 8 (4 IN, 4 OUT); I/O Records 21,000~3500 (Reference appendix 4); Control s 4 ; Output 4 relay; Input 8 points; LCD Display 16 2 LCD; Indicator 8 LED; Reader Technology SYRIS RS485 format; User PIN 4 digital codes; Communication ports RS485 2,Optional 10M/100M Ethernet; / b WiFi Baud Rate Default 19,200bps, 4,800 9,600 19,200 38,400 57, ,200

5 230, , ,600 1,843,200 (Over 115,200, must use MDNET-2); ID & 01-99; Holidays 366 days; Expand Reader & Module SYRIS series module; Anti Pass-Back Level 3 or Group Anti Pass-Back; Speaker Output Built-in (max 0.2W); Time Zone 60 time zones; Timer 0-32 Timer; Group (Application set) 64 Application Set; Software SY-SOFT-95A / SYW95A-NET-V2 / SYW95A-V3 & V2 & V832.11; Keypad 16key keypad; Humidity 10% to 95% (Non-condensing); Operating Temperature --20 to 70 ; Power Supply 8V to 24V DC / 0.3W to 3W; Dimensions(mm) 135W 175H 45D () / 122W 117H 25D (Control Board); Ethernet TCP/IP Module Optional MDNET-2; SD Card Module Optional MDNSD-2 & SD Card 256M 512M 1G; Wiegand Module Optional MDWIE-2; Power Supply Module Over Ethernet Optional MDPOE-1; Section 2: SY210NT Wire & Quick Installing 2.1 Required Equipment Power supply 12V / DC(required); and Reader connection RS485 twisted pairs; and Computer connection SYLINK-F via USB or RS232; Relay connection Relay connects with electromagnetic lock. 2.2 Selecting a Mounting Location Select a mounting location for the unit using the following guidelines: Next to the door that is being supervised; To avoid setting controller in huge noise areas; It is recommended that setting up location should be visible for flashing card to access easily. The height of setting location should between 45 to 50 inches to the floor. 2.3 Typical Mounting Diagram 2.6 Connecting Lock Wiring Diagram Open by power supply failure wiring diagram +12V Normal Close (NC) Common (COM) Normal Open (NO) + - Electric Deadbolt Electric Strikes Open by start power supply wiring diagram Electronic Lock wiring diagram 2.7 Connecting button to Open 2.4 Installing SY210NT 1. Separate the controller and its back panel by pulling the upper side; 2. Use the back panel to mark the screw holes position on the wall; 3. Screw back panel on the wall by using four (4) screws (provided); 4. Put back controller to the back panel; 2.8 Connecting the detection 2.5 Installing the Reader Wiring Diagram 2.9 Connecting power supply +V+VM

6 2.10 General Wiring Diagram Section 4: SY210NT V5 Settings 4.1 System Functions Functions ID Set ID when s are serious connection (EX:First controller ID: 0001 ; Second controller ID:0002). <Setting> Same Card Time The period means flashing one card twice or continuous. <Setting> Section 3: SY210NT V5 Setting Introduction Enlarge 3.1 Setting Menu MU 3.2 Setting Menu Logout MU input password. success. or MU 3.3 Show Version MU Logout yyyy/mm/dd (Thu) hh:mm:ss Using choice to logout. Show time expresses successfully. or MU SY210NT4V S/N:XXXXXXXX Using choice to version information. 3.4 SY210NT Factory Defaults Description Factory Default 1234 ID Same card PIN lock ID:[0001] [0000] sec [3] 次 Invalid Lock While user input invalid password over setting times, the system will lock down. User can't input when system lucked. <Setting> Comm. Baud rate Communication Baud rate (4A/4R). Default is e.8.1. <Setting> DI Setting The NO/NC settings of DI are in control and module. <Setting> Elevator Mode Enable elevator function to control elevator. <Setting> Card Volume Set the max number of card. <Setting> Module Auto Detect Module The system will search new added module by setting the function enabled. <Setting> Module ID Setting Set up module ID by input serial number. <Setting> MDWIE-2 ID Setting Set up reader channel ID.<Setting> Relay Set up the parameters of door open relay. <Setting> Push Button ( Open) Set up the parameters of push button that is used for door open. <Setting> APB Setting Set up the level of APB (0~3).<Setting> Lock time Comm. Baud rate Elevator mode [060]sec e.8.1 [4A] e.8.1 [4R] [NO] Setting Setting. Change password in unpredictable period is recommended. <Setting> Max card Relay Push button ID:[1~4] CH:[1~4] Times 05 sec No APB setting [0] System Utility Backup 60 Day(Optional MDNSD-2 & SD Card) Add Card Add Card. <Setting> Delete Card Delete Card. <Setting> System Utility Date Setting Set date according to user request. <Setting> Time Setting Set time according to user request. <Setting> System Reboot Reboot system. <Setting> 6 Data Backup / Restore

7 Backup/Restore data to system (SD Card required). <Setting> System Initial Set system to default factory setting. <Setting> 4.2 Card Management Add Card Auto Add Card By Serial Add the card automatically by serial (flash card continuously). <Setting> Add Card By Card No. Add the card by card number.(set card ID first then flash card) <Setting> Edit Card Edit Card Status Set the card as enabled or disabled. <Setting> Edit Card PIN Edit the card PIN (4 digital codes). <Setting> Edit Card APB Set APB of card as enabled or disabled. <Setting> Delete Card Delete Card by Card Number Delete car by card number. <Setting> Delete All Cards <Setting> Delete all cards in controller Show Card After flashing the card, system will show card information. <Setting> All Card APB Setting All card APB condition setting. <Setting> 4.3 Fingerprint Management Add Fingerprint Add fingerprint. <Setting> Delete Fingerprint Delete single fingerprint. <Setting> Delete All Fingerprint Delete all fingerprints. <Setting> Section 5: Set up SY210NT V5 Step by Step 5.1 Function MU or MU Set ID [ _ ] System input password success or MU Same card time Same card time 000 sec Invalid Lock System input setting value. or MU Baud Rate Setting System PIN lock Error number [3] Lock time [060] sec input setting value. input setting value. or MU DI Setting System Comm. Baud rate Baud rate(4a) [19200,e,8,1] Baud rate(4r) [19200,e,8,1] Using choice rate, Using choice rate, or MU Elevator Mode System DI Setting ID [ 0 ] DI setting NO/NC:[ ] ID:0 is controller ID:1-8 is MDDIDO input setting value. 0=NO, 1=NC or MU Elevator mode Elevator mode [ No ] Set Max Card System Using choice YES / NO. or MU Max card Max card [ ] Record clear! [ No ] Card:[ ] Record:[ ] input setting value. Using choice YES / NO (Chooses YES only then to be able to change the setting value). Card:Max card number Record:Max I/O data. NOTE:If the user determines the change controller max card, then must first the data backup. After Record clear! [YES], IO data completely will delete 5.2 Reader Module Setting MU System [ _ ] input password Same Card Time ID ID 0001 input ID. or MU System Module success. System 7

8 5.2.1 Module Auto Detect System Module or MU Module Auto detect Auto detect Waiting. Find module:[ 02 ]! Reader Module ID Setting System Module auto detect display. Found two modules. or MU MDWIE-2 ID Setting System Module Module ID setting ID setting [ SYRDS1/S5/L5 ] S/N [ _ ] Module ID [ 0 ] Using choice module. input serial number. input module ID. or MU MDWIE-2 ID setting MDWIE-2 CH-ID [ ] MDWIE-2 ID setting 5.3 Function Setting MU Using choice Reader Channel ID and input Channel ID. or MU Relay System [ 1~4 ] [ _ ] System No :[ 1 ]. input password. success. setting door. or MU Push Button System [ 1~4 ] Relay Relay ID:[ 0 ] CH:[ 01 ] Time [ 005 ] sec input ID and CH. input time. or MU APB Setting System [ 1~4 ] Push button Push button ID:[ 0 ] CH:[ 01 ] input ID and CH. or MU APB setting APB setting Level: [ 0 ] setting level 0~ Card Function Setting MU or MU PIN Setting System [ _ ] input password. success. 按鍵顯示畫面備註 or MU Add Card System PIN setting No:[ 1 ] PIN setting [ _ ] input number (1-3). input password. or MU Delete Card System Add card No:[ 1 ] Punch card input number (1-3). Please punch the card. or MU 5.5 System Utility MU Delete card No:[ 1 ] input number (1-3). or MU Date Setting System System utility [ _ ] System System utility input password. success. or MU Time Setting System System utility System utility Date setting Date setting [ 07 / 08 / 15 ] setting date. (YY/MM/DD). 按鍵顯示畫面備註 or MU System Reboot System System utility System utility Time setting Time setting [15:00:37 ] setting time.(hh:mm:ss) or MU System utility Reboot 8

9 System Reboot [ No ] Data Backup / Restore System System utility (The use in optional SD Card Module) Uses the SD card backup data Using choice YES / NO. or MU System utility Backup / Restore Backup / Restore [ Manual Backup ] 2007/06/22 16:19 [ YES ] Manual backup [ Waiting xxxx ] Manual backup Uses the SD card restore data Using choice Backup or Restore. Using choice YES / NO. Start a backup display. Backup success. or MU System Initial System System utility System utility Backup / Restore Backup / Restore [ Manual Restore ] Restore from [ Manual Backup ] 2007/06/22 16:19 [ YES ] Restore [ Waiting xxxx ] System Reboot Using choice Manual Backup or Restore. Using choice Manual Backup / Auto Backup. Using choice YES / NO. Start a restore display. After restore success system automatic reboot. or MU 5.6 Card Management System utility Initial Initial [ YES ] System Reboot Using choice YES / NO After system reboot resetting system unit to factory defaults. Punch card Please punch the card. (can punch card continuously) NOTE:The manual serial number increases the card commonly used in to increase some specific serial number the card. If punch card continuously, the number will from input number starts to increase. EX:Input number 1000,when punch second card can jump Edit Card Card Condition Setting (Valid / Invalid) Card or MU Card PIN Setting Edit card Card No.:[00001] Edit card Status Status [ Enable ] Card Card No.:[00001] input number. Using choice Status APB or PIN Using choice Enable or Disable Card APB Setting Edit card PIN PIN [ YES ] PIN PIN:[ 0000 ] Card Card No.:[00001] Using choice Status APB or PIN Using choice YES / NO input password Single Card Delete Card Edit card APB APB [ Disable ] Using choice Status APB or PIN Using choice Enable or Disable or MU Delete card MU [ _ ] input password. success Delete All Card Delete card By no. Delete card No.:[00001] Using choice By no. or All. input number. or MU Card Card Delete cards Add Card Add Card By Serial Card or MU or MU Add Card By No. Add Card Add Card By serial Punch card Using choice By serial or By No. Please punch the card. (can punch card continuously) or MU Add Card Cards Browse Card Delete card All Delete All [ Yes ] Delete All Using choice By no. or All. Using choice YES / NO. Delete all card success. or MU Show card ID Punch card Please punch the card B Show data of the card. or MU Add Card By No. Add Card No.:[01000] Using choice By serial or By No. input number All Card APB Setting Card 9

10 MU or MU All card APB setting APB setting [ Enable ] Using choice Enable Disable or Reset 5.7 Fingerprint Management Connection Fingerprint Reader uses. MU or MU [ _ ] Fingerprint Fingerprint ID:[ 1 ] input password. success. input fingerprint ID Add Fingerprint Fingerprint Fingerprint ID:[ X ] or MU Fingerprint Add Fingerprint No:[ 0001 ] Fingerprint Add Fingerprint No:[ 0002 ] input fingerprint number. After the bi bi voice press the fingerprint to press on the fingerprint sensor. The bright OK green light expresses successfully. Add fingerprint or use CLR exit Delete Fingerprint Fingerprint Fingerprint ID:[ X ] or MU Fingerprint Delete Fingerprint No:[ 0001 ] Fingerprint Delete Delete All Fingerprint Fingerprint Fingerprint ID:[ X ] input fingerprint number. After serge the long sound, deletes successfully. or MU Fingerprint Delete all Delete all [ Yes ] Delete all Waiting Delete all Using choice YES / NO. Fingerprint deleting. Delete all fingerprint success. 5.8 Resetting the SY210NT Unit to Factory Defaults Please refer to

11 Appendix 1:Quick Reference Programming Table Quick Reference Programming Table 1. System ID 2. Same card Time 3. PIN Lock 4. Comm. Baud rate 5. DI setting 6. Elevator mode 7. Max card 2. Module 1. Auto detect 2. ID setting Relay 2. Push button 3. APB setting PIN setting 2. Add card 3. Delete card 5. System Utility 1. Date setting 2. Time setting 3. Reboot 4. Backup / Restore 5. System Initial 2. Card 3. Fingerprint 1. Add card 1. By serial 2. By no. 2. Edit card 1. Status 2. PIN 3. APB 3. Delete card 1. By no. 2. All 4. Show card ID 5. All card APB setting 1. Fingerprint Add 2. Fingerprint Delete 3. Fingerprint Delete all 11

12 Appendix 2:Programming Worksheet Installation Information 1. Set Name: Programming Worksheet 2. Device Title: 3. Device ID: 4. Installs Company: 5. Reader Number: 6. Tel.: Device Setting Information Item Default Setting Value 1234 Same Card Time 0 PIN Lock Error Number 3 PIN Lock Time 60 sec sec Baud Rate (4A) 19200,e,8,1,,, Reader Baud Rate(4R) 19200,e,8,1,,, Elevator Mode No Max Card Relay ID: CH: ID:_-_-_-_ CH: Relay Time 005 sec / / / sec Push Button ID: CH: ID:_-_-_-_ CH: APB Setting Level:0 / 0/ 0/ 0 Level: / / / SD Card Backup Data Time yyyy / mm / dd / / 12

13 Appendix 3:Card Information Record Sheet Cardholder Name Card Number Auxiliary Card PIN 13

14 Appendix 4: SY210NT V5 Card Capacity and I/O Data List SY210NT V5 Card Capacity and I/O Data List 1. Normal(SSB,TSB) 1. High-capacity (SSA,TSA) 2.High-capacity (SSA-L,TSA-L) Card Capacity I/O DATA Card Capacity I/O DATA Card Capacity I/O DATA

15 Appendix 5:Using the SY210NT System Q1: How to setting reader ID? What Reader ID and are relate? MU A1:SY210NT-V5 series oneself have no inside set up to read card system, [1234 ] input password. After expansion installs Reader can use reader card function. ID and OK The Setup lamp signal is bright Setup, success. Reader ID are setting [1] by factory default, so after setting Reader ID *2 System expansion installs Reader, Otherwise can deliver failure because ID duplicates. Reader module ID setting *1 Module MU [1234 ] input password. Module Auto detect Auto detect Waiting ID: xx Find Module :[01] OK automatic detects display. Found one module. OK The Setup lamp signal is bright Setup, success. CLR*4 2007/12/30 (Sun) 17:52:53 Setting success. *2 System Note 4: can automatic detects Modules and connected. In normal condition, if installed two devices,then system demonstrate Find Module:[02] OK. *1 Module Module Auto detect *1 Module ID Setting ID Setting [ SYRDS1 / S5 / L5 ] Reader module ID setting Using choice module. (Note 1) module ID setting (Note 3) S / N [ ] Input serial number. (Note 2) CLR*3 Module ID [1] Module ID Setting 2007/12/30 (Sun) 17:52:53 Input Module ID. Presses the key confirmation ID setting. Setting success. Reader ID setting step by step: Note 1:The module can differentiate as follows. READER DIDO PRINT SYRDK5 SYRDF5/F6 SYRDT5 Proximity Card Reader. Have SYRDS1, SYRDS5, SYRDL5 and MDWIE. Extend Module. Have MDDIDO-1S and MDDIDO-16. Printer Module. Keypad Proximity Reader. Fingerprint Reader. LCD Proximity Card Reader. Note 2:User can find the serial number on the packing box or serial number label at the back of device. Note 3:Readers ID alignment rule as follows, External Reader: ID: 1 ID: 2 ID: 3 ID: 4 Internal Reader: ID: 5 ID: 6 ID: 7 ID: 8 automatic detects Readers and Modules. After setting Readers ID has to can take effect with connected. The setting step by step as follows: 15

16 Q2: How to add the card? A2: Add Cards Q3: How to setting the push button from controller? A3: DI1 is push button of 1 MU [1234 ] OK *3 Card Please punch the card. (Has not used) Please punch the card. (Has used) CLR Add Card Add Card By Serial Punch Card Punch Card [0001] Punch Card Card Use Add Card By Serial input password. The Setup lamp signal is bright Setup, success. Automatic add cards by serial. Please punch the card. (Has not used) The first input card 0001 starts to sort. Punch card continuously then number automatic increasing. If the card has already used system would appear a message Card Use. MU *2 *2 [1234 ] OK System input password. The Setup lamp signal is bright Setup, success. No : [1] [1] Expresses the 1. *1 Push button Push button ID : [0] CH : [01] Push button Push button setting. DI setting ID:[0] Indicate to be in use controller inner part, CH:[01] Indicate to be in use channel 01. Presses the key to confirmation. CLR*3 2007/12/30 (Sun) 17:52:53 Setting success. 16

17 Q4: How to Connect HID Readers of Wiegand interface with? A4:Connect Wiegand Module wiring diagram. SY210 4R+ 12V (Yellow Wire) NC1 (Brown Wire) COM1 (Orange Wire) NO1 (Yellow Wire) NC2 (Green Wire) COM2 (Blue Wire) NO2 (Violet Wire) +12VDC EM Lock EM Lock BLACK GRE D1 WHITE D0 BLACK GRE D1 WHITE D0 (Green Wire) (Black Wire) (Red Wire) 4R+ 4R- 4R- 12V (Yellow Wire) ID #1 ID #5 ID #2 ID #3 BLACK GRE D1 WHITE D0 BLACK GRE WHITE D1 D0 HID HID HID HID (Green Wire) (Black Wire) (Red Wire) M4 M2 M3 M5 DI1 (Brown Wire) DI2 (Orange Wire) DI3 (Yellow Wire) DI4 (Green Wire) (Black Wire) 4A- (Blue Wire) 4A+ (Violet Wire) 4R- (Gray Wire) 4R+ (White Wire) (Black Wire) Magnetic sensors ( sensors) ********Note******* (4A-) and (4A+) are used to connect to other controller or converter ******************* 17

18 Q5: How to use MDDIDO Module Connecting the Exit Detector or Exit Button? A5: Connecting the Exit Detector or Exit Button wiring diagram The Appliance of MDDIDO-1S with SY210NT controller SY210NT-V5 M4 M2 NC1 COM1 NO1 NC2 COM2 NO2 4A- 4A+ 4R- 4R+ + 12VDC (Brown Wire) (Orange Wire) (Yellow Wire) (Green Wire) (Blue Wire) (Violet Wire) (Blue Wire) (Violet Wire) (Gray Wire) (White Wire) (Black Wire) EM Lock EM Lock ********Note******** (4A-) and (4A+) are used to connect to other controller or converter ******************** M3 DI1 DI2 DI3 DI4 (Brown Wire) (Orange Wire) (Yellow Wire) (Green Wire) (Black Wire) Magnetic sensors ( sensors) M5 4R+ (Yellow Wire) 4R- (Green Wire) (Black Wire) 12V (Red Wire) (Brown Wire) (Orange Wire) (Yellow Wire) (Green Wire) (Black Wire) DI1 DI2 DI3 DI4 Exit Buttons (Brown Wire) (Orange Wire) (Yellow Wire) (Green Wire) (Blue Wire) (Violet Wire) COM1 NO1 COM2 NO2 4R+ (Yellow Wire) 4R- (Green Wire) (Black Wire) 12V (Red Wire) (Brown Wire) DI1 (Orange Wire) DI2 (Yellow Wire) DI3 (Green Wire) DI4 (Black Wire) Break glass switches Normal Close ( NC ) Common ( COM ) Normal Open ( NO ) Relay DO Feature 10A 28VDC / 5A 250VAC (Brown Wire) (Orange Wire) (Yellow Wire) (Green Wire) (Blue Wire) (Violet Wire) COM1 NO1 COM2 NO2 18

19 MU *2 [1234 ] OK System input password. The Setup lamp signal is bright Setup, success. *2 No : [1] [1] Expresses the 1. *1 CLR*3 Push button Push button ID : [1] CH : [01] Push button 2007/12/30 (Sun) 17:52:53 Push button setting. DI setting ID:[0] Indicate to be in use expansion module1, CH:[01] Indicate to be in use channel 01. Presses the key to confirmation. Setting success. 19

20 Appendix 6: General Wiring Diagram SY210NT-V5 SERI AL CONTROLLER WIRING DIAGRAM 控制器接線圖 Relay Relay Max : 7A 30VDC / 7A 250VAC Normal Close ( NC ) Common ( COM ) Normal Open ( NO ) DO Feature External Speak 外接喇叭 RELAY 3 RELAY 4 M15 (Brown Wire 棕色 ) (Orange Wire 橙色 ) (Yellow Wire 黃色 ) (Green Wire 綠色 ) (Blue Wire 藍色 ) (Violet Wire 紫色 ) (Brown Wire 棕色 ) (Orange Wire 橙色 ) (Yellow Wire 黃色 ) (Green Wire 綠色 ) (Blue Wire 藍色 ) (Violet Wire 紫色 ) NC 3 COM 3 NO 3 NC 4 COM 4 NO 4 NC 1 COM 1 NO 1 NC 2 COM 2 NO 2 LCD DISPLAY 顯示器 Keyboard and LED 鍵盤及燈號 2007/01/01 (Mon) *** 09:05:37 *** POE Power Over Ethernet 網路供電模組 POE RELAY 1 RELAY 2 MDNET-2 Ethernet Module 乙太網路模組 MDNET-2 Wiegand Module 維根模組 DI5 DI6 DI7 DI8 Wiegand (Blue Wire 藍色 ) (Violet Wire 紫色 ) (Gray Wire 灰色 ) (White Wire 白色 ) (Black Wire 黑色 ) (Brown Wire 棕色 ) (Orange Wire 橙色 ) (Yellow Wire 黃色 ) (Green Wire 綠色 ) (Black Wire 黑色 ) DI1 DI2 DI3 DI4 4R+ 4A- 4R- 4R+ 4A- 4A+ 4R- 4A+ Connect to SYLINK and other s 連結 SYLINK 與其它控制器 Reader +12Vdc Reade r +12Vdc DIDO Printer Modul e +12Vdc Digital Input 輸入接點 Can be: sensor Push button or other NC/NO output sensor (Black Wire 黑色 ) (Green Wire 綠色 ) BATTERY 備用電池 SD Module SD 記憶卡模組 (White Wire 白色 ) (Red Wire 紅色 ) (Red Wire 紅色 ) 8 ~ 20 Vdc 直流 (Black Wire 黑色 ) (Black Wire 黑色 ) 接地 DC Power Input 直流電源 Tamper SW. 反破壞開關 20

SY120SA Basic Operation Manual

SY120SA Basic Operation Manual SY120SA Basic Operation Manual V3.22 Content 1.Login/Logout Procedure & Longin Password alter... Page 1 2.Add Card Operation Procedure..Page 2 3.Delete Card Operation Procedure...Page 2 4.Modify Card Operation

More information

SYRIS SY110SA. Operating Manual. Ver:1.60

SYRIS SY110SA. Operating Manual. Ver:1.60 SYRIS SY110SA Operating Manual Ver:1.60 Apr.15.2006 Table of content TABLE OF CONTENT...2 INTRODUCTION...- 1 - Ⅰ. DO DEFAULT CONTRAST TABLE...- 1 - Ⅱ. DI DEFAULT CONTRAST TABLE...- 1 - Ⅲ. OPERATION...-

More information

GV-AS Controller. Installation Guide

GV-AS Controller. Installation Guide GV-AS Controller Installation Guide Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. 2011 GeoVision, Inc. All rights reserved.

More information

Operation manual For NG BIOSINGLE Version 1.1

Operation manual For NG BIOSINGLE Version 1.1 Operation manual For NG BIOSINGLE Version 1.1 SMART-I ELECTRONICS SYSTEMS PVT. LTD.(An ISO 9001:2008 certified company) R&D, Training & Customer Support Center: First Floor, Arihant Plaza Phase II, Village-Ovala,

More information

F6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode

F6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode -Fingerprint Access Control/Reader Function Description Enter the Programming Mode - Simplified Instruction Operation (Factory default:1234) Change the Master Code Add Fingerprint User Add Card User Add

More information

Single Door Standalone Access Control User Manual

Single Door Standalone Access Control User Manual Single Door Standalone Access Control User Manual Reading this manual carefully before install and use the device 1. Packing List Name Quantity Remarks Keypad User manual Screw driver Rubber plug Self

More information

GV-Card Reader. User s Manual

GV-Card Reader. User s Manual GV-Card Reader User s Manual Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. READER-B 2016 GeoVision, Inc. All rights

More information

Finger Vein Access Control device Quick Start Guide Version: 1.0 Date: June USB slot. USB slot

Finger Vein Access Control device Quick Start Guide Version: 1.0 Date: June USB slot. USB slot Overview Fingerprint & Finger Vein Device Front Left Side: Finger Vein Device Touch screen Card reader Fingerprint reader Finger vein reader Finger vein sensor: During registration, after finger touches

More information

ACTpro Single Door IP Controller. Operating & Installation Instructions

ACTpro Single Door IP Controller. Operating & Installation Instructions ACTpro 1500 Single Door IP Controller Operating & Installation Instructions 18-00079 Issue 1 This manual refers to the ACTpro 1500 a TCP/IP based control unit supporting up to 32 doors. Access Control

More information

Standalone Keypad Access Control. User Manual. Please read the manual carefully before use this unit

Standalone Keypad Access Control. User Manual. Please read the manual carefully before use this unit Standalone Keypad Access Control User Manual Please read the manual carefully before use this unit 1. Packing List Name Quantity Remarks Keypad 1 User manual 1 Screw driver 1 Φ20mm 60mm,Special for keypad

More information

Standalone Keypad Access Control. User Manual. SS-TS2000 Size:120*80*25 mm

Standalone Keypad Access Control. User Manual. SS-TS2000 Size:120*80*25 mm Standalone Keypad Access Control User Manual SS-TS2000 Size:120*80*25 mm Please read the manual carefully before use this unit 1. Packing List Name Quantity Remarks Keypad 1 User manual 1 Screw driver

More information

GV-AS/EV Controller. User s Manual

GV-AS/EV Controller. User s Manual GV-AS/EV Controller User s Manual Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. AS100.110.120.210.400.410.810-EV48-C

More information

QUICK START GUIDE. 2.4 Inch TFT Terminal Time Attendance & Access Control

QUICK START GUIDE. 2.4 Inch TFT Terminal Time Attendance & Access Control QUICK START GUIDE 2.4 Inch TFT Terminal Time Attendance & Access Control Safety Precautions The following precautions are to keep user safe and prevent any damage. Please read carefully before installation.

More information

W Series. Color Screen Fingerprint & Card Time Attendance and Access Control W 1 W 2

W Series. Color Screen Fingerprint & Card Time Attendance and Access Control W 1 W 2 W Series Color Screen Fingerprint & Card Time Attendance and Access Control W 1 W 2 W1 & W2 Features * Standard 2.8-inch TFT LCD, 512MB Flash, industrial high speed CPU * Touch keypad & touch active sensor

More information

Waterproof. Keypad/Reader/Controller

Waterproof. Keypad/Reader/Controller Waterproof Keypad/Reader/Controller User Manual W1-C W3-C User manual 1. Packing List Name Quantity Remarks Digital Keypad-W1-C/W3-C 1 User manual 1 Screw driver 1 Rubber bungs 4 6*27mm, used for fixing

More information

Quick Start Guide. GV-Video Server. 1 Introduction. Packing List

Quick Start Guide. GV-Video Server. 1 Introduction. Packing List Introduction Quick Start Guide GV-Video Server Welcome to the GV-Video Server Quick Start Guide. In the following sections, you will learn about the basic installations and configurations of the GV-Video

More information

UC-2000 Installation Manual Unicorn Computers Technology Limited

UC-2000 Installation Manual Unicorn Computers Technology Limited UC2000 Installation Manual Copyright 2003. All rights reserved. Table of Contents Specifications 2 Enclosure for the UC2000 Controller 3 Unicorn Access Control System Configuration 4 UC2000 Controller

More information

CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions

CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions Packing List NAME MODEL/SIZE QTY Self tapping screw 0.15 x 1.06 (4mm 27 mm) Rubber plug 0.23 x 1.2 (6mm 30 mm) Star screw driver

More information

AR-721E-V2 (AR-721E-V2-X) AR-701B-X Fit 35mm DIN Rail or Mount directly 16,000 32,000. Connector CN18 Host TCP/IP. Code Pin Description

AR-721E-V2 (AR-721E-V2-X) AR-701B-X Fit 35mm DIN Rail or Mount directly 16,000 32,000. Connector CN18 Host TCP/IP. Code Pin Description SOYAL ACCESS CTROL SYSTEM AR-E-V V0 Contents Product User Guide Panel Mounting Base (AR-E-V-X) Metal Box (AR-E-V-M) Option Option Specification CPU Memory Power Supply Power Consumption Interface / Baud

More information

Access control panel U-Prox IC E (Elevator control)

Access control panel U-Prox IC E (Elevator control) 1.003 Access control panel U-Prox IC E (Elevator control) Installation and programming manual About this document http://u-prox.com This manual covers installation, adjustment and use of U-Prox IC E (hereinafter

More information

CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions

CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions 1. Packing List Qty Name Remarks 1 1 1 2 2 1 Keypad User manual Screwdriver Wall plugs Self-tapping screws Torx screw 0.8 x 2.4

More information

Digital Keypad Introduction

Digital Keypad  Introduction K2 Digital Keypad Introduction The K02 uses the latest microprocessor technology to operate door strikes and security systems that require a momentary (timed) or latching dry contact closure. All programming

More information

GV-AS/EV Controller. User s Manual

GV-AS/EV Controller. User s Manual GV-AS/EV Controller User s Manual Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. ASEV-H 2016 GeoVision, Inc. All rights

More information

Quick Start Guide. GV-CS1320 Camera Access Controller

Quick Start Guide. GV-CS1320 Camera Access Controller Quick Start Guide GV-CS1320 Camera Access Controller Thank you for purchasing GV-CS1320 Camera Access Controller. This guide is designed to assist the new user in getting immediate results from the controllers.

More information

Quick Start Guide. GV-Video Server

Quick Start Guide. GV-Video Server Quick Start Guide GV-Video Server Thank you for purchasing GV-Video Server. This guide is designed to assist the new user in getting immediate results from the GV-Video Server. For advanced information

More information

GV-AS200 Controller. Hardware Installation Guide

GV-AS200 Controller. Hardware Installation Guide GV-AS200 Controller Hardware Installation Guide Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. 2008 GeoVision, Inc.

More information

Instruction Manual. Vogue. Security. Technology. Innovation 2013-V01

Instruction Manual. Vogue. Security. Technology. Innovation 2013-V01 Instruction Manual DH16A-60DTE Model 60 with plastic keypad, stand alone access control DH16A-60DTQE Model 60 with plastic keypad, networked access control 2013-V01 Security Technology Vogue Innovation

More information

CM-110SK Standalone Keypad Installation Instructions

CM-110SK Standalone Keypad Installation Instructions CM-0SK Standalone Keypad Installation Instructions. Packing List Qty Name Remarks 2 2 Keypad User manual Screwdriver Wall plugs Self-tapping screws Torx screw 0.8 x 2.4 Φ(20 mm 60 mm) 0.24 x.2 Φ (6 mm

More information

Quick Start Guide. GV-Video Server

Quick Start Guide. GV-Video Server Quick Start Guide GV-Video Server Thank you for purchasing GV-Video Server. This guide is designed to assist new users in getting immediate results from the GV-Video Server. For advanced information on

More information

Quick Start Guide. ProBio & ProFAC + ZKBioSecurity 3.0

Quick Start Guide. ProBio & ProFAC + ZKBioSecurity 3.0 Quick Start Guide ProBio & ProFAC + ZKBioSecurity 3.0 CONTENT 1 Safety Precautions...2 On Using Face Recognition Device...3 Device Overview...5 Product Dimensions & Installation...6 Power Connection...7

More information

TEC100 USER/INSTALLER MANUAL V2.0 REV. 03/2018

TEC100 USER/INSTALLER MANUAL V2.0 REV. 03/2018 TEC100 USER/INSTALLER MANUAL V2.0 REV. 03/2018 00. CONTT 01. SAFETY INSTRUCTIONS INDEX 01. SAFETY INSTRUCTIONS STANDARDS TO FOLLOW 02. PRODUCT PRODUCT PROFILE TECHNICAL PARAMETERS 03. INSTALLATION PRODUCT

More information

VIDI-AC-2CS Access Controller/ Reader

VIDI-AC-2CS Access Controller/ Reader VIDI-AC-2CS Access Controller/ Reader User Manual CONTENTS INTRODUCTION 2 INSTALLATION.4 STANDALONE MODE 6 CONTROLLER MODE.11 WIEGAND READER MODE.. 13 ADVANCE APPLICATION..14 1 INTRODUCTION The VIDI-AC-2CS

More information

Installation Instructions. i-net Access Control Units. Part Code: IA-PCB IA-ACB IA-ACU IA-KIT

Installation Instructions. i-net Access Control Units. Part Code: IA-PCB IA-ACB IA-ACU IA-KIT Installation Instructions i-net Access Control Units Part Code: IA-PCB IA-ACB IA-ACU IA-KIT This device is configured for DHCP. Identity Access software will find this device, go to setup and controller,

More information

ACTpro 1500 Single Door IP Controller

ACTpro 1500 Single Door IP Controller ACTpro 1500 Single Door IP Controller ACTpro 1520 Single Door IP Controller with 12 V DC 2 amp power supply. Operating & Installation Instructions 18-00085 Issue 2 This manual refers to the ACTpro 1500

More information

SF200. Installation Guide & Quick Start Guide. 2 TFT AC Terminal Version: 1.0 Date: June 2014

SF200. Installation Guide & Quick Start Guide. 2 TFT AC Terminal Version: 1.0 Date: June 2014 SF200 Installation Guide & Quick Start Guide 2 TFT AC Terminal Version: 1.0 Date: June 2014 All design and specification declared are subject to change without notice in advance. Contents Safety Precautions

More information

DG-800 Stand-Alone Proximity Reader Instruction Manual

DG-800 Stand-Alone Proximity Reader Instruction Manual DG-800 Stand-Alone Proximity Reader Instruction Manual I. Features 1. Memory volume up to 1000+10 proximity cards/tokens and PINs with the programming time up to 0.5 seconds. 2. Access modes: a. Only Proximity

More information

INSTALLATION INSTRUCTIONS 920P EntryCheck TM

INSTALLATION INSTRUCTIONS 920P EntryCheck TM 801 Avenida Acaso, Camarillo, Ca. 93012 (805) 494-0622 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS 920P EntryCheck TM The EntryCheck 920P Indoor/Outdoor Keypad is a surface-mount

More information

Two-door Access Controller

Two-door Access Controller Two-door Access Controller Quick Start Guide V1.0.0 Preface Overview This document elaborates on structure, installation, interface and wiring of two-door access controller. Symbol Definition The following

More information

W3-M. Metal waterproof standalone access control/reader. User Manual

W3-M. Metal waterproof standalone access control/reader. User Manual W3M Metal waterproof standalone access control/reader User Manual Name Digital Keypad W3M User Manual Screw driver Rubber bungs Selftapping screws Diode 1. Packing List Quantity 1 1 1 4 4 1 Remark 6*27mm,

More information

IPassan Installation guide

IPassan Installation guide IPassan Installation guide 1 Content 1 Overview... 3 1.1 Features... 3 1.2 Hardware... 3 1.2.1 s... 3 1.2.2 Extra modules... 5 1.3 IPassan manager... 7 2 Installation... 7 2.1... 8 2.1.1 Power supply...

More information

INSTALLATION GUIDE. InBio Pro Series Access Control Panels. Date: June, 2016 Version: 1.3

INSTALLATION GUIDE. InBio Pro Series Access Control Panels. Date: June, 2016 Version: 1.3 INSTALLATION GUIDE InBio Pro Series Access Control Panels Date: June, 2016 Version: 1.3 2 What s in the Box 2 Screws & Anchors 2 Screwdriver 4 Diode CONTENT Contents What s in the Box...2 Optional accessories...4

More information

Pegasus Equipments Export Limited. Local Contact:

Pegasus Equipments Export Limited. Local Contact: Pegasus Equipments Export Limited Add: #31G, Haiyige, Scienway Palace Science & Technology Industrial Park Shenzhen, China. Tel: +86 755 2658 3464 +86 755 2658 3596 Fax: +86 755 8611 0167 web: www.pegasusexport.com

More information

User Manual. PCKeypad Wireless Keypad

User Manual. PCKeypad Wireless Keypad User Manual PCKeypad Wireless Keypad Description The PCKeypad is a wireless keypad with a PentaCODE transmitter built-in. It works with all of Elsema s PCR series receivers. The installer has the option

More information

Quick Installation Guide MAC1000/MAC1000SR STANDALONE BIOMETRIC CONTROLLER

Quick Installation Guide MAC1000/MAC1000SR STANDALONE BIOMETRIC CONTROLLER MAC1000/MAC1000SR STANDALONE BIOMETRIC CONTROLLER Table of contents 1 PRODUCT INTRODUCTION... 2 1.1 NAME AND FUNCTION OF EACH PART... 2 1.2 CABLE COLOR TABLE... 4 1.3 CABLE SELECTION... 6 2 IDENTIFYING

More information

EZ-TAG2 Manual_Layout 5 11/12/ :14 Page 1 U S E R M A N UAL

EZ-TAG2 Manual_Layout 5 11/12/ :14 Page 1 U S E R M A N UAL EZ-TAG2 Manual_Layout 5 11/12/2012 09:14 Page 1 USER MANUAL EZ-TAG2 Manual_Layout 5 11/12/2012 09:14 Page 2 Contents EZ-TAG2 and Back Plate 1 x Security Torx Key 4 x Screws and raw plugs 1 x Marking out

More information

GV-RK1352 and GV-R1352 Card Reader

GV-RK1352 and GV-R1352 Card Reader GV-RK1352 and GV-R1352 Card Reader The GV-RK1352 and GV-R1352 are card readers designed to recognize identifications cards. GV-RK1352 comes with keypad, allowing it to also recognize PIN codes. Featured

More information

W3-H Waterproof Keypad/Reader/Controller

W3-H Waterproof Keypad/Reader/Controller W3-H Waterproof Keypad/Reader/Controller User Manual 1. Packing list Name Quantity Digital Keypad W3-H 1 User Manual 1 Screw Driver Rubber Bungs Self Tapping Screws Diode 1 4 4 1 Manager Card 2 Remark

More information

Partizan PAB-FC2. Fingerprint scan time Fingerprint identification time. <0.5 s < % <0.0198% Ingress protection rating

Partizan PAB-FC2. Fingerprint scan time Fingerprint identification time. <0.5 s < % <0.0198% Ingress protection rating 1. Features & Technical Parameters 1.1 Features: Partizan PAB-FC2 Metal vandalproof housing Secure and reliable biometric fingerprint recognition Simple for using, wiring can be done by a user without

More information

AIM- DAC System. DAC844 User Manual. Anviz Global Inc

AIM- DAC System. DAC844 User Manual. Anviz Global Inc DAC844 User Manual 1 Notice and Disclaimer This manual s sole purpose is to assist installers and/or users in the safe and efficient installation and usage of the system and/or product, and/or software

More information

Fingerprint Access Standalone User s Manual

Fingerprint Access Standalone User s Manual Fingerprint Access Standalone User s Manual V1.1.1 1 Table of Contents 1 Overview... 1 2 Device Structure and Installation... 2 2.1 Device Structure... 2 2.2 Device Installation... 3 3 System Structure...

More information

Click Save to return to the main Setup screen.

Click Save to return to the main Setup screen. ON-SITE Setup Guide Thank you for purchasing the ON-SITE. This guide will assist you in the setup of the system. You can call for FREE technical support to get help anytime at 757-258-0910. Please note,

More information

Portals 14 What is a portal? 14 Hardware 15 RS232 to RS USB to RS TCP/IP to RS Add a Serial Portal 16 Add a Network portal 16

Portals 14 What is a portal? 14 Hardware 15 RS232 to RS USB to RS TCP/IP to RS Add a Serial Portal 16 Add a Network portal 16 PROS LITE User Manual Version 2.0.0 www.visual-plus.com Table of Contents Getting Started 5 Starting PROS Lite 5 Create a Portal 5 Adding a control panel 6 Adding a user 7 Upload users to a controller

More information

Fingerprint Access Control F1. User Manual

Fingerprint Access Control F1. User Manual Fingerprint Access Control F1 User Manual 1. Introduction F1 is a metal shell standalone fingerprint access control, using the America Atmel s MCU, with precise electron circuit and good productive technology.

More information

RD-SR2 ACCESS SECURITY PRODUCTS LTD. Proximity Card Reader with Remote Control. User Manual

RD-SR2 ACCESS SECURITY PRODUCTS LTD. Proximity Card Reader with Remote Control. User Manual RD-SR2 Proximity Card Reader with Remote Control User Manual INTRODUCTION The RD-SR2 is a compact, weather resistant multi-function card reader that can be used as a standalone programmable access control

More information

7612 Programming Instructions

7612 Programming Instructions 7612 Programming Instructions Built-in Proximity reader Read Range 65mm odulation ASK at 125kHz Compatible Cards ALL 26-Bit EM Cards 7612 is a vandal resistant proximity card and keypad access control

More information

IBA-7612 Programming Instructions

IBA-7612 Programming Instructions IBA-7612 Programming Instructions Built-in Proximity reader Read Range 65mm odulation ASK at 125kHz Compatible Cards ALL 26-Bit EM Cards IBA-7612 is a vandal resistant proximity card and keypad access

More information

INSTALLATION INSTRUCTIONS 920 EntryCheck TM

INSTALLATION INSTRUCTIONS 920 EntryCheck TM 801 Avenida Acaso, Camarillo, Ca. 93012 (805) 494-0622 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS 920 EntryCheck TM The EntryCheck 920 Indoor/Outdoor Keypad is a surface-mount

More information

User Manual. Split access control with intelligent secured power supply.

User Manual. Split access control with intelligent secured power supply. User Manual Split access control with intelligent secured power supply. Contents. Introduction, features and specifications. Installation and Wiring Diagram 3. Manager Card Operation 4. User Settings 5.

More information

User Manual. Before using this device, read and follow all instructions for safety

User Manual. Before using this device, read and follow all instructions for safety User Manual Before using this device, read and follow all instructions for safety Copyrightc 2014 KJTECH Co., Ltd. All rights reserved. It is provided for informational purposes only in this manual. All

More information

Wiring Guide. EP.NMiNi 2. Version 1.04 Last Updated:

Wiring Guide. EP.NMiNi 2. Version 1.04 Last Updated: Wiring Guide EP.NMiNi 2 Version 1.04 Last Updated: 31-01-2013 Before you begin Technical Support If you cannot find the answer to your question in this manual or in the Help files, we recommend you contact

More information

C5S120 Installation and Connection Guide

C5S120 Installation and Connection Guide C5S120 Installation and Connection Guide Version: V1.1 1. Cautions Please note the following cautions. Mis-operation may lead to personal injury or equipment failure: 1) Do not energize the system before

More information

Technical Manual Nova: Cabinet Security Management System (CSMS)

Technical Manual Nova: Cabinet Security Management System (CSMS) Technical Manual Nova: Cabinet Security Management System (CSMS) KP_nova_TM_160501_EN 1 Publication May, 2016, Keyprocessor BV Paasheuvelweg 20 1105BJ Amsterdam, The Netherlands www.keyprocessor.com/nova

More information

icam7000s SERIES HARDWARE GUIDE Packing List CONTACTLESS CARD READER RECESS MOUNT (Optional) ISO/ANSI COMPLIANT EASY INSTALLATION What s in the Box

icam7000s SERIES HARDWARE GUIDE Packing List CONTACTLESS CARD READER RECESS MOUNT (Optional) ISO/ANSI COMPLIANT EASY INSTALLATION What s in the Box icam7000s SERIES HARDWARE GUIDE ADVANCED MULTIFACTOR BIOMETRIC IRIS READER VERSION 1.0 icam7000s-t (Titanium Color) icam7000s-b (Black Color) DUAL IRIS ISO/ANSI COMPLIANT FACE CAMERA EASY INSTALLATION

More information

Installation & User Manual

Installation & User Manual Contents Installation Instructions 3 Installation Diagrams 4 System Overview 6 Wiring Diagrams 8 Network Diagrams 9 Operation Instructions Fingerprint Enrollment 12 21 Wi-Enterprise Controller www.transmittersolutionssmart.com

More information

Face & Fingerprint Recognition Product

Face & Fingerprint Recognition Product Realand Bio Co., LTD. Face & Fingerprint Recognition Product Hardware User Manual PRO6. Date: June 2016 Product Specification PC Software Version Cloud Based Version LCD Display 2.8 inch TFT Color Screen

More information

Quick Start Guide. GV-AS / EV Controller

Quick Start Guide. GV-AS / EV Controller Quick Start Guide GV-AS / EV Controller Thank you for purchasing GV-AS / EV Controller (GV-AS100 / AS110 / AS120 / AS210 / AS400 / AS410 / AS810 and GV-EV48). This guide is designed to assist the new user

More information

P4 P5 P6. Security trigger signal 2 Purple Security trigger signal Output 6 Thin Blue Wiegand DAT: 1 Input

P4 P5 P6. Security trigger signal 2 Purple Security trigger signal Output 6 Thin Blue Wiegand DAT: 1 Input SOYAL ACCESS CONTROL SYSTEM AR- (E) / (EF) V Contents AR- (EF):Fingerprint Products User Guide Terminal Cables Tools DO AR- (E) Or MT P P P P P P P P P P P P Water proof Strip Optional Products User Guide

More information

Biometrics Device Access controller Fingerprint & Finger Vein V Connector Table () Cable: P Wire Application Anti-Tamper Switch Wire Color Red Orange

Biometrics Device Access controller Fingerprint & Finger Vein V Connector Table () Cable: P Wire Application Anti-Tamper Switch Wire Color Red Orange SOYAL ACCESS CONTROL SYSTEM AR- (EF-V) / (EV-V) V Contents AR- (EF-V):Fingerprint Products User Guide Terminal Cables Tools Optional P P P AR- (EV-V):Vein P P P AR-RB Products User Guide Terminal Cables

More information

Installation and User Manual

Installation and User Manual S2 Metal Waterproof Access Control Unit Installation and User Manual (Ness Part No. 101-082) 1 Introduction Ness S2 is an advanced, waterproof (IP65 rated) proximity and PIN Access Controller. S2 can support

More information

DOLXFD1000B. Waterproof Access Control/Reader

DOLXFD1000B. Waterproof Access Control/Reader DOLXFD1000B Waterproof Access Control/Reader INTRODUCTION The DOLXFD1000B is a single- entry multi-function Access Controller with integrated keypad and card reader. It is designed and manufactured to

More information

Installation & User Manual V2.08

Installation & User Manual V2.08 YOUR SECURITY IS OUR PRIORITY Other products from GSD Contents Installation Instructions Installation Diagrams System Overview Wiring Diagrams Network Diagrams Operation Instructions Fingerprint Enrollment

More information

PoE IEEE802.3at MIFARE MHz. EM 125 KHz

PoE IEEE802.3at MIFARE MHz. EM 125 KHz ACT-457A 5.7 RISC-based RFID Panel PC Features PoE IEEE802.3at 5.7 TFT touch color screen, full interface display, all operations can be done directly on the touch screen Integrated with RMI Alchemy AU1250

More information

CP150B Vandal & Weather Resistant Keypad Security Systems

CP150B Vandal & Weather Resistant Keypad Security Systems Vandal & Weather Resistant Keypad Security Systems EN Security System CP150B - Vandal & Weather Resistant Keypad The CP150B keypad provides alarm and or access control functionality when used on selected

More information

CRC220 and CRC221 INSTALLATION GUIDE. REF No.: DOC0014 ISSUE: 09

CRC220 and CRC221 INSTALLATION GUIDE. REF No.: DOC0014 ISSUE: 09 CRC220 and CRC221 INSTALLATION GUIDE REF No.: DOC0014 ISSUE: 09 30th July 2015 2 Contents CRC220 & CRC221 INSTALLATION GUIDE 1. Scope 1-1 2. Introduction 2-1 2.1 Features 2-1 2.1.1. PCB Features 2-1 2.1.2.

More information

Smart HUB - HUB to expand one Master Controller s RS-485 port to 8 RS-485 ports - Use 12VDC power

Smart HUB - HUB to expand one Master Controller s RS-485 port to 8 RS-485 ports - Use 12VDC power Hardware Overview - SmartKey Master Controller - Smart HUB - - RFID Readers Master Controller HUB Features: RFID Readers SmartKey Master Controller - 1MB internal memory (2MB optional), can hold up to

More information

Standalone Access Control

Standalone Access Control Standalone Access Control BELL_A BELL_B D0 D1 D_in(LED) Open (BZ) COM ALARM- Light Green Pink Red Black Green White Brown Yellow Blue Purple Orange Grey Door Bell DC 12V Power Green White Reader Red Black

More information

EZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY

EZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY EZTAG PROXIMITY AND KEYPAD DOOR ENTRY USER MANUAL www.espuk.com EZTAG Manual_Layout.indd 8//06 5:8:0 System Components Proximity and Reader 0 x Proximity Tags x Hex Key x Plastic wall plug x Countersunk

More information

791/793 Easy Entry Keypads

791/793 Easy Entry Keypads 791/793 Easy Entry Keypads Description The DMP 791 and 793 Easy Entry LCD Keypads are the industry s first burglary/fire keypads with integrated access control capability. Each keypad provides three 2-button

More information

XT200 Intelligent Network Router

XT200 Intelligent Network Router XT200 Intelligent Network Router Installation Manual V0103 SYRIS Technology Corporation 12F, NO.12 Sec. 1, Taijunggang Rd. Taichung city, Taiwan(403) TEL: 04-2207-8888 FAX: 04-2207-9999 Email:service@syris.com

More information

INSTALLATION GUIDE 2.4 Inch TFT Terminal Time Attendance & Access Control

INSTALLATION GUIDE 2.4 Inch TFT Terminal Time Attendance & Access Control STALLATION GUIDE.4 Inch TFT Terminal Time Attendance & Access Control Optional accessories Safety Precautions The following precautions are to keep user s safe and prevent any damage. Please read carefully

More information

QUICK START GUIDE. 2.4 Inch Finger Vein Terminal Time Attendance & Access Control

QUICK START GUIDE. 2.4 Inch Finger Vein Terminal Time Attendance & Access Control QUICK START GUIDE 2.4 Inch Finger Vein Terminal Time Attendance & Access Control Version: 1.0 Date: Apr., 2017 1 2.4-Inch TFT LCD USB Storage Device Port Keypad& Card Reader Doorbell & LED Indicator Fingerprint

More information

Specifications: Features:

Specifications: Features: ROFU Features: Applicable card mode EM Card / Key Fob 1 Administrator and 200 Users 200 Proximity Cards / Key fobs Access Modes:Use Bluetooth smartphone or Card / Key fob to access Built-in Tamper alarm

More information

E5 Series. Installation and Setup Guide

E5 Series. Installation and Setup Guide 801 Avenida Acaso, Camarillo, Ca. 90312 (805) 494-0622 Fax: (805) 494-8861 www.sdcsecurity.com E-mail: service@sdcsecurity.com E5 Series Installation and Setup Guide P:\Installation Instructions\Access

More information

EL-ST100 KEYPAD CONTROLLER

EL-ST100 KEYPAD CONTROLLER WIRING DIAGRAM EL-ST100 KEYPAD CONTROLLER WEATHER-PROOF STANDALONE ACCESS CONTROLLER WITH KEYPAD & PROXIMITY TECHNOLOGY Programming and Installation Manual NOTE: www.elock2u.com ICT at work! Version 3.6

More information

ON-LINE PROXIMTY ACCESS CONTROLLER OPERATION MANUAL MODEL: HA3035 VERSION: 2.9x

ON-LINE PROXIMTY ACCESS CONTROLLER OPERATION MANUAL MODEL: HA3035 VERSION: 2.9x ON-LINE PROXIMTY ACCESS CONTROLLER OPERATION MANUAL MODEL: HA05 VERSION: 2.9x HEART ENTERPRISE CO. LTD. HEART ENTERPRISE CO., LTD. 0 Chapter I Introduction. Introduction 5.2 Features 5. Specification 6.

More information

1. Product Specification

1. Product Specification 1. Product Specification Item Specification Voltage 12VDC +10%, Current 1.2A Lock Relay 12VDC/2A Environmental Temperature working:0 ~45 ; storage:-10 ~55 Relative humidity working:40%~90%rh; Card Capacity

More information

Atlas ATLAS INSTALLATION MANUAL SECTIONS INDEX EQUIPMENT / MAIN FUNCTIONS TECHNICAL FEATURES ATLAS: PIN IN/OUT / GENERAL VIEW

Atlas ATLAS INSTALLATION MANUAL SECTIONS INDEX EQUIPMENT / MAIN FUNCTIONS TECHNICAL FEATURES ATLAS: PIN IN/OUT / GENERAL VIEW Atlas INSTALLATION MANUAL SECTIONS INDEX EQUIPMENT / MAIN FUNCTIONS 1 TECHNICAL FEATURES 2 : PIN IN/OUT / GENERAL VIEW 3 : IP ADDRESS CONFIGURATION 4 WARNINGS 5 SETTING TABLES 6 : CONNECTIONS EXAMPLES

More information

Installation guide for PR602LCD type access controller

Installation guide for PR602LCD type access controller Roger Access Control System Installation guide for PR602LCD type access controller Firmware version: 1.18.6 or newer Document version: Rev. K 2016 ROGER sp. z o.o. sp.k. All rights reserved. This document

More information

installation quick guide integrated access control & environmental monitoring

installation quick guide integrated access control & environmental monitoring installation quick guide integrated access control & environmental monitoring Introduction This Installation Quick Guide is suitable for standard wallmountable AX300 controllers. Illustrative technical

More information

REX F-0-9 Standalone or Access Controller

REX F-0-9 Standalone or Access Controller REX F-0-9 Standalone or Access Controller Power supply The controller need s external power supply to operate. The Spider W40 power supply is sufficient to power two controllers and two 12V electric strikes

More information

INSTALLATION SHEET 791 and 793 Easy Entry Keypads

INSTALLATION SHEET 791 and 793 Easy Entry Keypads INSTALLATION SHEET 791 and 793 Easy Entry Keypads Description The DMP 791 and 793 Easy Entry LCD Keypads are the industry s first burglary/fire keypads with integrated access control capability. Each keypad

More information

Building Technologies. Access Control SiPass networked - simple & networkable for everyday use

Building Technologies. Access Control SiPass networked - simple & networkable for everyday use Building Technologies Access Control SiPass networked - simple & networkable for everyday use SiPass networked Innovative access control SiPass networked is part of the SiPass product range for use in

More information

Wiring Guide EP.NMINI. Version 1.02 Last Updated:

Wiring Guide EP.NMINI. Version 1.02 Last Updated: Wiring Guide EP.NMINI Version 1.02 Last Updated: 14-10-2014 1 Note: See http://www.entrypass.net/ for updates, revisions, and download the latest installation manual There are currently 2 version of EntryPass

More information

2000 Series e/em Style Keypad Installation and Programming Manual

2000 Series e/em Style Keypad Installation and Programming Manual 2000 Series e/em Style Keypad Installation and Programming Manual Document Number: 6054022 Revision: 0 Date: 12/21/06 Table of Contents Table of Contents Section 1: Introduction... 6 1 Product Description...6

More information

PW6000 Modular Access Control System PW6000 Intelligent Controllers and Modules

PW6000 Modular Access Control System PW6000 Intelligent Controllers and Modules Modular Access Control System The next generation of the PW-Series family improves on the existing PW technology to offer superior features and benefits. The PW-Series Modular Control System is an advanced

More information

VICON ACCESS CONTROL CONTROLLERS

VICON ACCESS CONTROL CONTROLLERS VICON ACCESS CONTROL CONTROLLERS Also available in white Over-the-Door Controller Master Controller Multi-Door Kit Elevator/IO Controller Product at a Glance The Vicon Access Control (VAX) system consists

More information

T&A Fingerprint machine

T&A Fingerprint machine Installation Guide series 2 V1.0 T&A Fingerprint machine Installation Guide series 2 Content 1. Before Installing... 1 1.1 Notice... 1 1.2 View of Operation Panel... 3 1.3 View of Power and Comm. Port...

More information

Operation Manual. Thank you for selecting Keyking products. Please read this manual thoroughly before use. Models: TC418/419 Standalone Controller

Operation Manual. Thank you for selecting Keyking products. Please read this manual thoroughly before use. Models: TC418/419 Standalone Controller Operation Manual Thank you for selecting Keyking products. Please read this manual thoroughly before use. Models: TC418/419 Standalone Controller KEYKING GROUP Index Chapter 1: Summay...3 1.1 Outline...3

More information

RBR-SB-KTZ001 LAR 2. User Manual

RBR-SB-KTZ001 LAR 2. User Manual RBR-SB-KTZ001 LAR 2 User Manual INTRODUCTION KTZ001 is a compact, waterproof stand-alone programmable access control system that provides proximity entry for up to 2000 users. Read both EM and HID card.

More information

Installation Guide for PR311SE and PR311SE-BK v1.0 Access Controllers Rev. B

Installation Guide for PR311SE and PR311SE-BK v1.0 Access Controllers Rev. B Installation Guide for PR311SE and PR311SE-BK v1.0 Access Controllers Rev. B Introduction This document contains minimum information that is necessary to properly install the device and to perform its

More information