SY210NT V5. Networking Muti-Doors Controller Installation Manual V0110
|
|
- Dominic Strickland
- 6 years ago
- Views:
Transcription
1 SY210NT V5 Networking Muti-s Installation Manual V0110 WARNING: This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer. The entire manual should be carefully read. SYRIS Technology Corp. 21F-2, NO.12, Sec1, Taijunggang Rd, Taichung, Taiwan (403) Tel: Fax:
2 SECTION 1: INTRODUCTION TO SY210NT V PRODUCT OVERVIEW ABOUT THIS MANUAL New in this Version Fast Setting Index Sheet and Card Record Sheet FEATURES SPECIFICATIONS...4 SECTION 2: SY210NT WIRE & QUICK INSTALLING REQUIRED EQUIPMT SELECTING A MOUNTING LOCATION TYPICAL MOUNTING DIAGRAM INSTALLING SY210NT INSTALLING THE READER WIRING DIAGRAM5 2.6 CONNECTING DOOR LOCK WIRING DIAGRAM CONNECTING BUTTON TO DOOR OP CONNECTING THE DOOR DETECTION CONNECTING POWER SUPPLY...5 SECTION 3: SY210NT V5 SETTING INTRODUCTION SETTING MU LOGIN SETTING MU LOGOUT SHOW VERSION SY210NT FACTORY DEFAULTS...6 SECTION 4: SY210NT V5 SETTINGS SYSTEM FUNCTIONS Functions Module System Utility CARD MANAGEMT Add Card Edit Card Delete Card Show Card All Card APB Setting FINGERPRINT MANAGEMT Add Fingerprint Delete Fingerprint Delete All Fingerprint... 7 SECTION 5: SET UP SY210NT V5 STEP BY STEP CONTROLLER FUNCTION Set ID Same Card Time Invalid Lock Baud Rate Setting DI Setting Elevator Mode Set Max Card READER MODULE SETTING Module Auto Detect Reader Module ID Setting MDWIE-2 ID Setting DOOR FUNCTION SETTING Relay Push Button APB Setting MASTER CARD FUNCTION SETTING PIN Setting Add Card Delete Card SYSTEM UTILITY Date Setting Time Setting System Reboot Data Backup / Restore System Initial CARD MANAGEMT Add Card Add Card By Serial Add Card By No Edit Card Card Condition Setting (Valid / Invalid) Card PIN Setting Card APB Setting
3 Single Card Delete Delete All Card Cards Browse All Card APB Setting FINGERPRINT MANAGEMT Add Fingerprint Delete Fingerprint Delete All Fingerprint RESETTING THE SY210NT UNIT TO FACTORY DEFAULTS...10 APPDIX 1:QUICK REFERCE PROGRAMMING TABLE 11 APPDIX 2:PROGRAMMING WORKSHEET...12 APPDIX 3:CARD INFORMATION RECORD SHEET13 APPDIX 4: SY210NT V5 CARD CAPACITY AND I/O DATA LIST 14 APPDIX 5:USING THE SY210NT SYSTEM...15 Q1: How to setting reader ID? What Reader ID and are relate?...15 Q2: How to add the card?...16 Q3: How to setting the push button from controller? 16 Q4: How to Connect HID Readers of Wiegand interface with?...17 Q5: How to use MDDIDO Module Connecting the Exit Detector or Exit Button?...18 APPDIX 6: GERAL WIRING DIAGRAM
4 Section 1: Introduction to SY210NT V5 MDNET-1 Module The functions are same as MDNET Product Overview 4. Printer Module Networking Multi-s can control 4 doors, link 8 card readers (4 IN, 4 can connect to the following printers directly or reports printing via OUT), use 63,000 cards and 210,000 I/O data record at most. (Reference printer module. appendix 4) 1. Impact Printers 2. Ink Jet Printer 3. Laser Printers SY210NT V5 Network Multi-s provides perfect functions and stable & reliable quality. * The controller can supply 63,000 people to use at most. * Single controller can manage 4 doors In/Out at the same time. * Regional Anti-Pass Back (APB) function will be activated without PC on-line. * The local APB will be activated in LAN. * The motherboard produced by the SMD technology. The quality is stable and reliable. Easy Setting All setting can be set by using controller keypad and LCD monitor(16x2 Char). You can make choice of purchase of expansion module that divides into two types: internal and external. Internal module of controller include: 1. MDNET-2 Ethernet Converter Ethernet Communication Converter used to convert RS485 series signal Fast Setting Index Sheet and Card Record Sheet into TCP/IP package. According to different network application types, the User can find out a setting location by referring the Quick Reference Programming module provides two types:server mode & Client mode. Table, appendix 1. The module will wait for the signal from network and it will send decode User can print and record Card Information by using appendix 3.. signal to HOST CPU through series communication port under Server mode. The module will re-package the signal and resend on network while MDDIDO Module divides MDDIDO-16 channel (16 voltage free input, 16 relay output) and MDDIDO-1S 2 channel (4 voltage free input, 2 relay output). System extendibility:user can use MIDDO module expansion of system when first program insufficient for user need; MDDIDO Module is easy to expansion; e.g. Add controller, Readers or DIDO Modules etc. 3. MDWIE-1 (Wigand Module install inside of the ) MDWIE-1 Wigand Module has 2 S/N. Each number represents a channel, is similar to RS485 Reader; First W26Reader use first Serial NO. Reader ID setting( ID=1, Firs door; ID=2;Second door..). When expand the MDWIE-1 Module to transform the RS485 interface into the Wiegand interface, user can connect with each kind of devices of Wiegand interface About this Manual This Installation Manual provides installation and setting instructions for SY210NT V5. Please read this manual carefully before installing or setting the SY210NT New in this Version The subject matters of the manual are focus on update of SY210NT V5: 1.Increase the number of user:the number of user can up to 63,000. I/O records can up to 21,000. (Reference appendix 4) 2.The time of door open by hand is longer:the time can be set as 9999 seconds or above. 3.Backup SD Card:The types of backup are Manual /Automatic. The backup / restore set can up to 10 sets. 4. Invalid password entering event handle:user can set times or lock time while error password input (1~999 sec). 1.3 Features received reply from the CPU HOST. And then the command cycle will be 1. Internal extension Module optional: done. User can add MDNET-2 network module to expand network function interface. (a) (b) 10/100M Ethernet Converter(MDNET-2). 4CH Wigand Signal Input Module(MDWIE-2). (c) SD Card module (MDSD-2 applies SD Card whose memory size of 2. MDPOE-1 Ethernet Power supplier module (Power over 256MB 512MB 1GB). Ethernet) (d) POE Power over Ethernet Module (MDPOE-1,Client). Power over Ethernet is called PoE that is the technology about power 2. The controller can be run with the software: SYW95A-V V2 V3 SYW95A supply. PoE can transmit electrical power over standard twisted-pair cable in -V2-NET and SY-SOFT-95A. an Ethernet network. We can supply power from HUB by using this 3. User can adjust the number of cards and record capacity of I/O data according to technology without connect other power source. need. 3. MDWIE-2 (Wiegand Signal Input Module) After installing 4 CH Wigand signal input module (MDWIE-2), user can connect four readers that include reader fingerprint etc. All devices as mention have Wiegand interface. 4. Promote number of User/Card and I/O data record:if using the new version of SY-SOFT-95A, the card/user capacity can increase to 21,000; High-capacity Device can promote number of User/Card to 63,000 and promote I/O data records to 210,000 at most. The whole speed of CPU promotes to 100 MIPS. (Reference 4. SD Card appendix 4). User can choose the SD CARD module to increase IO records or backup 5. After installing SD Card Module and SD Card, user can backup all data from the the controller data. The slot of SD CARD(MDSD-2) can compatible with the capacity of SD CARD include 256MB 512MB and 1GB. External Device of : controller. 6. Fast update firmware:support to update the firmware on-line through RS485 or Ethernet. 1. Reader 7. While Ethernet network module is added, the communication styles to HOST-PC are polling and auto-transmission. Both of the polling and auto-transmission can The Reader includes SYRDS1 Proximity Card Reader SYRDS5 Proximity run at the same time. The system provides not only efficient transmission but also Card Reader SYRDL5 Mini Proximity Reader SYRDT5 LCD Proximity Card Reader and SYRDF5/F6 Fingerprint Reader. System extendibility:link 8 readers at most. The types of Reader divide into 125K (EM) 13.56M (Mifare). response event immediately. While more and more doors in system, the excellent functions will be presented. 8. The system will send commands to related controller and modules to active fire control and fire alarm automatically through Ethernet converter. The functions also 2. MDDIDO Module can be handled through client PC. 1.4 Specifications Number of Cards 3,500 ~ 63,000; Number of Readers 8 (4 IN, 4 OUT); I/O Records 21,000~3500 (Reference appendix 4); Control s 4 ; Output 4 relay; Input 8 points; LCD Display 16 2 LCD; Indicator 8 LED; Reader Technology SYRIS RS485 format; User PIN 4 digital codes; Communication ports RS485 2,Optional 10M/100M Ethernet; / b WiFi Baud Rate Default 19,200bps, 4,800 9,600 19,200 38,400 57, ,200
5 230, , ,600 1,843,200 (Over 115,200, must use MDNET-2); ID & 01-99; Holidays 366 days; Expand Reader & Module SYRIS series module; Anti Pass-Back Level 3 or Group Anti Pass-Back; Speaker Output Built-in (max 0.2W); Time Zone 60 time zones; Timer 0-32 Timer; Group (Application set) 64 Application Set; Software SY-SOFT-95A / SYW95A-NET-V2 / SYW95A-V3 & V2 & V832.11; Keypad 16key keypad; Humidity 10% to 95% (Non-condensing); Operating Temperature --20 to 70 ; Power Supply 8V to 24V DC / 0.3W to 3W; Dimensions(mm) 135W 175H 45D () / 122W 117H 25D (Control Board); Ethernet TCP/IP Module Optional MDNET-2; SD Card Module Optional MDNSD-2 & SD Card 256M 512M 1G; Wiegand Module Optional MDWIE-2; Power Supply Module Over Ethernet Optional MDPOE-1; Section 2: SY210NT Wire & Quick Installing 2.1 Required Equipment Power supply 12V / DC(required); and Reader connection RS485 twisted pairs; and Computer connection SYLINK-F via USB or RS232; Relay connection Relay connects with electromagnetic lock. 2.2 Selecting a Mounting Location Select a mounting location for the unit using the following guidelines: Next to the door that is being supervised; To avoid setting controller in huge noise areas; It is recommended that setting up location should be visible for flashing card to access easily. The height of setting location should between 45 to 50 inches to the floor. 2.3 Typical Mounting Diagram 2.6 Connecting Lock Wiring Diagram Open by power supply failure wiring diagram +12V Normal Close (NC) Common (COM) Normal Open (NO) + - Electric Deadbolt Electric Strikes Open by start power supply wiring diagram Electronic Lock wiring diagram 2.7 Connecting button to Open 2.4 Installing SY210NT 1. Separate the controller and its back panel by pulling the upper side; 2. Use the back panel to mark the screw holes position on the wall; 3. Screw back panel on the wall by using four (4) screws (provided); 4. Put back controller to the back panel; 2.8 Connecting the detection 2.5 Installing the Reader Wiring Diagram 2.9 Connecting power supply +V+VM
6 2.10 General Wiring Diagram Section 4: SY210NT V5 Settings 4.1 System Functions Functions ID Set ID when s are serious connection (EX:First controller ID: 0001 ; Second controller ID:0002). <Setting> Same Card Time The period means flashing one card twice or continuous. <Setting> Section 3: SY210NT V5 Setting Introduction Enlarge 3.1 Setting Menu MU 3.2 Setting Menu Logout MU input password. success. or MU 3.3 Show Version MU Logout yyyy/mm/dd (Thu) hh:mm:ss Using choice to logout. Show time expresses successfully. or MU SY210NT4V S/N:XXXXXXXX Using choice to version information. 3.4 SY210NT Factory Defaults Description Factory Default 1234 ID Same card PIN lock ID:[0001] [0000] sec [3] 次 Invalid Lock While user input invalid password over setting times, the system will lock down. User can't input when system lucked. <Setting> Comm. Baud rate Communication Baud rate (4A/4R). Default is e.8.1. <Setting> DI Setting The NO/NC settings of DI are in control and module. <Setting> Elevator Mode Enable elevator function to control elevator. <Setting> Card Volume Set the max number of card. <Setting> Module Auto Detect Module The system will search new added module by setting the function enabled. <Setting> Module ID Setting Set up module ID by input serial number. <Setting> MDWIE-2 ID Setting Set up reader channel ID.<Setting> Relay Set up the parameters of door open relay. <Setting> Push Button ( Open) Set up the parameters of push button that is used for door open. <Setting> APB Setting Set up the level of APB (0~3).<Setting> Lock time Comm. Baud rate Elevator mode [060]sec e.8.1 [4A] e.8.1 [4R] [NO] Setting Setting. Change password in unpredictable period is recommended. <Setting> Max card Relay Push button ID:[1~4] CH:[1~4] Times 05 sec No APB setting [0] System Utility Backup 60 Day(Optional MDNSD-2 & SD Card) Add Card Add Card. <Setting> Delete Card Delete Card. <Setting> System Utility Date Setting Set date according to user request. <Setting> Time Setting Set time according to user request. <Setting> System Reboot Reboot system. <Setting> 6 Data Backup / Restore
7 Backup/Restore data to system (SD Card required). <Setting> System Initial Set system to default factory setting. <Setting> 4.2 Card Management Add Card Auto Add Card By Serial Add the card automatically by serial (flash card continuously). <Setting> Add Card By Card No. Add the card by card number.(set card ID first then flash card) <Setting> Edit Card Edit Card Status Set the card as enabled or disabled. <Setting> Edit Card PIN Edit the card PIN (4 digital codes). <Setting> Edit Card APB Set APB of card as enabled or disabled. <Setting> Delete Card Delete Card by Card Number Delete car by card number. <Setting> Delete All Cards <Setting> Delete all cards in controller Show Card After flashing the card, system will show card information. <Setting> All Card APB Setting All card APB condition setting. <Setting> 4.3 Fingerprint Management Add Fingerprint Add fingerprint. <Setting> Delete Fingerprint Delete single fingerprint. <Setting> Delete All Fingerprint Delete all fingerprints. <Setting> Section 5: Set up SY210NT V5 Step by Step 5.1 Function MU or MU Set ID [ _ ] System input password success or MU Same card time Same card time 000 sec Invalid Lock System input setting value. or MU Baud Rate Setting System PIN lock Error number [3] Lock time [060] sec input setting value. input setting value. or MU DI Setting System Comm. Baud rate Baud rate(4a) [19200,e,8,1] Baud rate(4r) [19200,e,8,1] Using choice rate, Using choice rate, or MU Elevator Mode System DI Setting ID [ 0 ] DI setting NO/NC:[ ] ID:0 is controller ID:1-8 is MDDIDO input setting value. 0=NO, 1=NC or MU Elevator mode Elevator mode [ No ] Set Max Card System Using choice YES / NO. or MU Max card Max card [ ] Record clear! [ No ] Card:[ ] Record:[ ] input setting value. Using choice YES / NO (Chooses YES only then to be able to change the setting value). Card:Max card number Record:Max I/O data. NOTE:If the user determines the change controller max card, then must first the data backup. After Record clear! [YES], IO data completely will delete 5.2 Reader Module Setting MU System [ _ ] input password Same Card Time ID ID 0001 input ID. or MU System Module success. System 7
8 5.2.1 Module Auto Detect System Module or MU Module Auto detect Auto detect Waiting. Find module:[ 02 ]! Reader Module ID Setting System Module auto detect display. Found two modules. or MU MDWIE-2 ID Setting System Module Module ID setting ID setting [ SYRDS1/S5/L5 ] S/N [ _ ] Module ID [ 0 ] Using choice module. input serial number. input module ID. or MU MDWIE-2 ID setting MDWIE-2 CH-ID [ ] MDWIE-2 ID setting 5.3 Function Setting MU Using choice Reader Channel ID and input Channel ID. or MU Relay System [ 1~4 ] [ _ ] System No :[ 1 ]. input password. success. setting door. or MU Push Button System [ 1~4 ] Relay Relay ID:[ 0 ] CH:[ 01 ] Time [ 005 ] sec input ID and CH. input time. or MU APB Setting System [ 1~4 ] Push button Push button ID:[ 0 ] CH:[ 01 ] input ID and CH. or MU APB setting APB setting Level: [ 0 ] setting level 0~ Card Function Setting MU or MU PIN Setting System [ _ ] input password. success. 按鍵顯示畫面備註 or MU Add Card System PIN setting No:[ 1 ] PIN setting [ _ ] input number (1-3). input password. or MU Delete Card System Add card No:[ 1 ] Punch card input number (1-3). Please punch the card. or MU 5.5 System Utility MU Delete card No:[ 1 ] input number (1-3). or MU Date Setting System System utility [ _ ] System System utility input password. success. or MU Time Setting System System utility System utility Date setting Date setting [ 07 / 08 / 15 ] setting date. (YY/MM/DD). 按鍵顯示畫面備註 or MU System Reboot System System utility System utility Time setting Time setting [15:00:37 ] setting time.(hh:mm:ss) or MU System utility Reboot 8
9 System Reboot [ No ] Data Backup / Restore System System utility (The use in optional SD Card Module) Uses the SD card backup data Using choice YES / NO. or MU System utility Backup / Restore Backup / Restore [ Manual Backup ] 2007/06/22 16:19 [ YES ] Manual backup [ Waiting xxxx ] Manual backup Uses the SD card restore data Using choice Backup or Restore. Using choice YES / NO. Start a backup display. Backup success. or MU System Initial System System utility System utility Backup / Restore Backup / Restore [ Manual Restore ] Restore from [ Manual Backup ] 2007/06/22 16:19 [ YES ] Restore [ Waiting xxxx ] System Reboot Using choice Manual Backup or Restore. Using choice Manual Backup / Auto Backup. Using choice YES / NO. Start a restore display. After restore success system automatic reboot. or MU 5.6 Card Management System utility Initial Initial [ YES ] System Reboot Using choice YES / NO After system reboot resetting system unit to factory defaults. Punch card Please punch the card. (can punch card continuously) NOTE:The manual serial number increases the card commonly used in to increase some specific serial number the card. If punch card continuously, the number will from input number starts to increase. EX:Input number 1000,when punch second card can jump Edit Card Card Condition Setting (Valid / Invalid) Card or MU Card PIN Setting Edit card Card No.:[00001] Edit card Status Status [ Enable ] Card Card No.:[00001] input number. Using choice Status APB or PIN Using choice Enable or Disable Card APB Setting Edit card PIN PIN [ YES ] PIN PIN:[ 0000 ] Card Card No.:[00001] Using choice Status APB or PIN Using choice YES / NO input password Single Card Delete Card Edit card APB APB [ Disable ] Using choice Status APB or PIN Using choice Enable or Disable or MU Delete card MU [ _ ] input password. success Delete All Card Delete card By no. Delete card No.:[00001] Using choice By no. or All. input number. or MU Card Card Delete cards Add Card Add Card By Serial Card or MU or MU Add Card By No. Add Card Add Card By serial Punch card Using choice By serial or By No. Please punch the card. (can punch card continuously) or MU Add Card Cards Browse Card Delete card All Delete All [ Yes ] Delete All Using choice By no. or All. Using choice YES / NO. Delete all card success. or MU Show card ID Punch card Please punch the card B Show data of the card. or MU Add Card By No. Add Card No.:[01000] Using choice By serial or By No. input number All Card APB Setting Card 9
10 MU or MU All card APB setting APB setting [ Enable ] Using choice Enable Disable or Reset 5.7 Fingerprint Management Connection Fingerprint Reader uses. MU or MU [ _ ] Fingerprint Fingerprint ID:[ 1 ] input password. success. input fingerprint ID Add Fingerprint Fingerprint Fingerprint ID:[ X ] or MU Fingerprint Add Fingerprint No:[ 0001 ] Fingerprint Add Fingerprint No:[ 0002 ] input fingerprint number. After the bi bi voice press the fingerprint to press on the fingerprint sensor. The bright OK green light expresses successfully. Add fingerprint or use CLR exit Delete Fingerprint Fingerprint Fingerprint ID:[ X ] or MU Fingerprint Delete Fingerprint No:[ 0001 ] Fingerprint Delete Delete All Fingerprint Fingerprint Fingerprint ID:[ X ] input fingerprint number. After serge the long sound, deletes successfully. or MU Fingerprint Delete all Delete all [ Yes ] Delete all Waiting Delete all Using choice YES / NO. Fingerprint deleting. Delete all fingerprint success. 5.8 Resetting the SY210NT Unit to Factory Defaults Please refer to
11 Appendix 1:Quick Reference Programming Table Quick Reference Programming Table 1. System ID 2. Same card Time 3. PIN Lock 4. Comm. Baud rate 5. DI setting 6. Elevator mode 7. Max card 2. Module 1. Auto detect 2. ID setting Relay 2. Push button 3. APB setting PIN setting 2. Add card 3. Delete card 5. System Utility 1. Date setting 2. Time setting 3. Reboot 4. Backup / Restore 5. System Initial 2. Card 3. Fingerprint 1. Add card 1. By serial 2. By no. 2. Edit card 1. Status 2. PIN 3. APB 3. Delete card 1. By no. 2. All 4. Show card ID 5. All card APB setting 1. Fingerprint Add 2. Fingerprint Delete 3. Fingerprint Delete all 11
12 Appendix 2:Programming Worksheet Installation Information 1. Set Name: Programming Worksheet 2. Device Title: 3. Device ID: 4. Installs Company: 5. Reader Number: 6. Tel.: Device Setting Information Item Default Setting Value 1234 Same Card Time 0 PIN Lock Error Number 3 PIN Lock Time 60 sec sec Baud Rate (4A) 19200,e,8,1,,, Reader Baud Rate(4R) 19200,e,8,1,,, Elevator Mode No Max Card Relay ID: CH: ID:_-_-_-_ CH: Relay Time 005 sec / / / sec Push Button ID: CH: ID:_-_-_-_ CH: APB Setting Level:0 / 0/ 0/ 0 Level: / / / SD Card Backup Data Time yyyy / mm / dd / / 12
13 Appendix 3:Card Information Record Sheet Cardholder Name Card Number Auxiliary Card PIN 13
14 Appendix 4: SY210NT V5 Card Capacity and I/O Data List SY210NT V5 Card Capacity and I/O Data List 1. Normal(SSB,TSB) 1. High-capacity (SSA,TSA) 2.High-capacity (SSA-L,TSA-L) Card Capacity I/O DATA Card Capacity I/O DATA Card Capacity I/O DATA
15 Appendix 5:Using the SY210NT System Q1: How to setting reader ID? What Reader ID and are relate? MU A1:SY210NT-V5 series oneself have no inside set up to read card system, [1234 ] input password. After expansion installs Reader can use reader card function. ID and OK The Setup lamp signal is bright Setup, success. Reader ID are setting [1] by factory default, so after setting Reader ID *2 System expansion installs Reader, Otherwise can deliver failure because ID duplicates. Reader module ID setting *1 Module MU [1234 ] input password. Module Auto detect Auto detect Waiting ID: xx Find Module :[01] OK automatic detects display. Found one module. OK The Setup lamp signal is bright Setup, success. CLR*4 2007/12/30 (Sun) 17:52:53 Setting success. *2 System Note 4: can automatic detects Modules and connected. In normal condition, if installed two devices,then system demonstrate Find Module:[02] OK. *1 Module Module Auto detect *1 Module ID Setting ID Setting [ SYRDS1 / S5 / L5 ] Reader module ID setting Using choice module. (Note 1) module ID setting (Note 3) S / N [ ] Input serial number. (Note 2) CLR*3 Module ID [1] Module ID Setting 2007/12/30 (Sun) 17:52:53 Input Module ID. Presses the key confirmation ID setting. Setting success. Reader ID setting step by step: Note 1:The module can differentiate as follows. READER DIDO PRINT SYRDK5 SYRDF5/F6 SYRDT5 Proximity Card Reader. Have SYRDS1, SYRDS5, SYRDL5 and MDWIE. Extend Module. Have MDDIDO-1S and MDDIDO-16. Printer Module. Keypad Proximity Reader. Fingerprint Reader. LCD Proximity Card Reader. Note 2:User can find the serial number on the packing box or serial number label at the back of device. Note 3:Readers ID alignment rule as follows, External Reader: ID: 1 ID: 2 ID: 3 ID: 4 Internal Reader: ID: 5 ID: 6 ID: 7 ID: 8 automatic detects Readers and Modules. After setting Readers ID has to can take effect with connected. The setting step by step as follows: 15
16 Q2: How to add the card? A2: Add Cards Q3: How to setting the push button from controller? A3: DI1 is push button of 1 MU [1234 ] OK *3 Card Please punch the card. (Has not used) Please punch the card. (Has used) CLR Add Card Add Card By Serial Punch Card Punch Card [0001] Punch Card Card Use Add Card By Serial input password. The Setup lamp signal is bright Setup, success. Automatic add cards by serial. Please punch the card. (Has not used) The first input card 0001 starts to sort. Punch card continuously then number automatic increasing. If the card has already used system would appear a message Card Use. MU *2 *2 [1234 ] OK System input password. The Setup lamp signal is bright Setup, success. No : [1] [1] Expresses the 1. *1 Push button Push button ID : [0] CH : [01] Push button Push button setting. DI setting ID:[0] Indicate to be in use controller inner part, CH:[01] Indicate to be in use channel 01. Presses the key to confirmation. CLR*3 2007/12/30 (Sun) 17:52:53 Setting success. 16
17 Q4: How to Connect HID Readers of Wiegand interface with? A4:Connect Wiegand Module wiring diagram. SY210 4R+ 12V (Yellow Wire) NC1 (Brown Wire) COM1 (Orange Wire) NO1 (Yellow Wire) NC2 (Green Wire) COM2 (Blue Wire) NO2 (Violet Wire) +12VDC EM Lock EM Lock BLACK GRE D1 WHITE D0 BLACK GRE D1 WHITE D0 (Green Wire) (Black Wire) (Red Wire) 4R+ 4R- 4R- 12V (Yellow Wire) ID #1 ID #5 ID #2 ID #3 BLACK GRE D1 WHITE D0 BLACK GRE WHITE D1 D0 HID HID HID HID (Green Wire) (Black Wire) (Red Wire) M4 M2 M3 M5 DI1 (Brown Wire) DI2 (Orange Wire) DI3 (Yellow Wire) DI4 (Green Wire) (Black Wire) 4A- (Blue Wire) 4A+ (Violet Wire) 4R- (Gray Wire) 4R+ (White Wire) (Black Wire) Magnetic sensors ( sensors) ********Note******* (4A-) and (4A+) are used to connect to other controller or converter ******************* 17
18 Q5: How to use MDDIDO Module Connecting the Exit Detector or Exit Button? A5: Connecting the Exit Detector or Exit Button wiring diagram The Appliance of MDDIDO-1S with SY210NT controller SY210NT-V5 M4 M2 NC1 COM1 NO1 NC2 COM2 NO2 4A- 4A+ 4R- 4R+ + 12VDC (Brown Wire) (Orange Wire) (Yellow Wire) (Green Wire) (Blue Wire) (Violet Wire) (Blue Wire) (Violet Wire) (Gray Wire) (White Wire) (Black Wire) EM Lock EM Lock ********Note******** (4A-) and (4A+) are used to connect to other controller or converter ******************** M3 DI1 DI2 DI3 DI4 (Brown Wire) (Orange Wire) (Yellow Wire) (Green Wire) (Black Wire) Magnetic sensors ( sensors) M5 4R+ (Yellow Wire) 4R- (Green Wire) (Black Wire) 12V (Red Wire) (Brown Wire) (Orange Wire) (Yellow Wire) (Green Wire) (Black Wire) DI1 DI2 DI3 DI4 Exit Buttons (Brown Wire) (Orange Wire) (Yellow Wire) (Green Wire) (Blue Wire) (Violet Wire) COM1 NO1 COM2 NO2 4R+ (Yellow Wire) 4R- (Green Wire) (Black Wire) 12V (Red Wire) (Brown Wire) DI1 (Orange Wire) DI2 (Yellow Wire) DI3 (Green Wire) DI4 (Black Wire) Break glass switches Normal Close ( NC ) Common ( COM ) Normal Open ( NO ) Relay DO Feature 10A 28VDC / 5A 250VAC (Brown Wire) (Orange Wire) (Yellow Wire) (Green Wire) (Blue Wire) (Violet Wire) COM1 NO1 COM2 NO2 18
19 MU *2 [1234 ] OK System input password. The Setup lamp signal is bright Setup, success. *2 No : [1] [1] Expresses the 1. *1 CLR*3 Push button Push button ID : [1] CH : [01] Push button 2007/12/30 (Sun) 17:52:53 Push button setting. DI setting ID:[0] Indicate to be in use expansion module1, CH:[01] Indicate to be in use channel 01. Presses the key to confirmation. Setting success. 19
20 Appendix 6: General Wiring Diagram SY210NT-V5 SERI AL CONTROLLER WIRING DIAGRAM 控制器接線圖 Relay Relay Max : 7A 30VDC / 7A 250VAC Normal Close ( NC ) Common ( COM ) Normal Open ( NO ) DO Feature External Speak 外接喇叭 RELAY 3 RELAY 4 M15 (Brown Wire 棕色 ) (Orange Wire 橙色 ) (Yellow Wire 黃色 ) (Green Wire 綠色 ) (Blue Wire 藍色 ) (Violet Wire 紫色 ) (Brown Wire 棕色 ) (Orange Wire 橙色 ) (Yellow Wire 黃色 ) (Green Wire 綠色 ) (Blue Wire 藍色 ) (Violet Wire 紫色 ) NC 3 COM 3 NO 3 NC 4 COM 4 NO 4 NC 1 COM 1 NO 1 NC 2 COM 2 NO 2 LCD DISPLAY 顯示器 Keyboard and LED 鍵盤及燈號 2007/01/01 (Mon) *** 09:05:37 *** POE Power Over Ethernet 網路供電模組 POE RELAY 1 RELAY 2 MDNET-2 Ethernet Module 乙太網路模組 MDNET-2 Wiegand Module 維根模組 DI5 DI6 DI7 DI8 Wiegand (Blue Wire 藍色 ) (Violet Wire 紫色 ) (Gray Wire 灰色 ) (White Wire 白色 ) (Black Wire 黑色 ) (Brown Wire 棕色 ) (Orange Wire 橙色 ) (Yellow Wire 黃色 ) (Green Wire 綠色 ) (Black Wire 黑色 ) DI1 DI2 DI3 DI4 4R+ 4A- 4R- 4R+ 4A- 4A+ 4R- 4A+ Connect to SYLINK and other s 連結 SYLINK 與其它控制器 Reader +12Vdc Reade r +12Vdc DIDO Printer Modul e +12Vdc Digital Input 輸入接點 Can be: sensor Push button or other NC/NO output sensor (Black Wire 黑色 ) (Green Wire 綠色 ) BATTERY 備用電池 SD Module SD 記憶卡模組 (White Wire 白色 ) (Red Wire 紅色 ) (Red Wire 紅色 ) 8 ~ 20 Vdc 直流 (Black Wire 黑色 ) (Black Wire 黑色 ) 接地 DC Power Input 直流電源 Tamper SW. 反破壞開關 20
SY120SA Basic Operation Manual
SY120SA Basic Operation Manual V3.22 Content 1.Login/Logout Procedure & Longin Password alter... Page 1 2.Add Card Operation Procedure..Page 2 3.Delete Card Operation Procedure...Page 2 4.Modify Card Operation
More informationSYRIS SY110SA. Operating Manual. Ver:1.60
SYRIS SY110SA Operating Manual Ver:1.60 Apr.15.2006 Table of content TABLE OF CONTENT...2 INTRODUCTION...- 1 - Ⅰ. DO DEFAULT CONTRAST TABLE...- 1 - Ⅱ. DI DEFAULT CONTRAST TABLE...- 1 - Ⅲ. OPERATION...-
More informationGV-AS Controller. Installation Guide
GV-AS Controller Installation Guide Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. 2011 GeoVision, Inc. All rights reserved.
More informationOperation manual For NG BIOSINGLE Version 1.1
Operation manual For NG BIOSINGLE Version 1.1 SMART-I ELECTRONICS SYSTEMS PVT. LTD.(An ISO 9001:2008 certified company) R&D, Training & Customer Support Center: First Floor, Arihant Plaza Phase II, Village-Ovala,
More informationF6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode
-Fingerprint Access Control/Reader Function Description Enter the Programming Mode - Simplified Instruction Operation (Factory default:1234) Change the Master Code Add Fingerprint User Add Card User Add
More informationSingle Door Standalone Access Control User Manual
Single Door Standalone Access Control User Manual Reading this manual carefully before install and use the device 1. Packing List Name Quantity Remarks Keypad User manual Screw driver Rubber plug Self
More informationGV-Card Reader. User s Manual
GV-Card Reader User s Manual Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. READER-B 2016 GeoVision, Inc. All rights
More informationFinger Vein Access Control device Quick Start Guide Version: 1.0 Date: June USB slot. USB slot
Overview Fingerprint & Finger Vein Device Front Left Side: Finger Vein Device Touch screen Card reader Fingerprint reader Finger vein reader Finger vein sensor: During registration, after finger touches
More informationACTpro Single Door IP Controller. Operating & Installation Instructions
ACTpro 1500 Single Door IP Controller Operating & Installation Instructions 18-00079 Issue 1 This manual refers to the ACTpro 1500 a TCP/IP based control unit supporting up to 32 doors. Access Control
More informationStandalone Keypad Access Control. User Manual. Please read the manual carefully before use this unit
Standalone Keypad Access Control User Manual Please read the manual carefully before use this unit 1. Packing List Name Quantity Remarks Keypad 1 User manual 1 Screw driver 1 Φ20mm 60mm,Special for keypad
More informationStandalone Keypad Access Control. User Manual. SS-TS2000 Size:120*80*25 mm
Standalone Keypad Access Control User Manual SS-TS2000 Size:120*80*25 mm Please read the manual carefully before use this unit 1. Packing List Name Quantity Remarks Keypad 1 User manual 1 Screw driver
More informationGV-AS/EV Controller. User s Manual
GV-AS/EV Controller User s Manual Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. AS100.110.120.210.400.410.810-EV48-C
More informationQUICK START GUIDE. 2.4 Inch TFT Terminal Time Attendance & Access Control
QUICK START GUIDE 2.4 Inch TFT Terminal Time Attendance & Access Control Safety Precautions The following precautions are to keep user safe and prevent any damage. Please read carefully before installation.
More informationW Series. Color Screen Fingerprint & Card Time Attendance and Access Control W 1 W 2
W Series Color Screen Fingerprint & Card Time Attendance and Access Control W 1 W 2 W1 & W2 Features * Standard 2.8-inch TFT LCD, 512MB Flash, industrial high speed CPU * Touch keypad & touch active sensor
More informationWaterproof. Keypad/Reader/Controller
Waterproof Keypad/Reader/Controller User Manual W1-C W3-C User manual 1. Packing List Name Quantity Remarks Digital Keypad-W1-C/W3-C 1 User manual 1 Screw driver 1 Rubber bungs 4 6*27mm, used for fixing
More informationQuick Start Guide. GV-Video Server. 1 Introduction. Packing List
Introduction Quick Start Guide GV-Video Server Welcome to the GV-Video Server Quick Start Guide. In the following sections, you will learn about the basic installations and configurations of the GV-Video
More informationUC-2000 Installation Manual Unicorn Computers Technology Limited
UC2000 Installation Manual Copyright 2003. All rights reserved. Table of Contents Specifications 2 Enclosure for the UC2000 Controller 3 Unicorn Access Control System Configuration 4 UC2000 Controller
More informationCV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions
CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions Packing List NAME MODEL/SIZE QTY Self tapping screw 0.15 x 1.06 (4mm 27 mm) Rubber plug 0.23 x 1.2 (6mm 30 mm) Star screw driver
More informationAR-721E-V2 (AR-721E-V2-X) AR-701B-X Fit 35mm DIN Rail or Mount directly 16,000 32,000. Connector CN18 Host TCP/IP. Code Pin Description
SOYAL ACCESS CTROL SYSTEM AR-E-V V0 Contents Product User Guide Panel Mounting Base (AR-E-V-X) Metal Box (AR-E-V-M) Option Option Specification CPU Memory Power Supply Power Consumption Interface / Baud
More informationAccess control panel U-Prox IC E (Elevator control)
1.003 Access control panel U-Prox IC E (Elevator control) Installation and programming manual About this document http://u-prox.com This manual covers installation, adjustment and use of U-Prox IC E (hereinafter
More informationCV-110SPK Standalone Keypad/Prox Access Control Installation Instructions
CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions 1. Packing List Qty Name Remarks 1 1 1 2 2 1 Keypad User manual Screwdriver Wall plugs Self-tapping screws Torx screw 0.8 x 2.4
More informationDigital Keypad Introduction
K2 Digital Keypad Introduction The K02 uses the latest microprocessor technology to operate door strikes and security systems that require a momentary (timed) or latching dry contact closure. All programming
More informationGV-AS/EV Controller. User s Manual
GV-AS/EV Controller User s Manual Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. ASEV-H 2016 GeoVision, Inc. All rights
More informationQuick Start Guide. GV-CS1320 Camera Access Controller
Quick Start Guide GV-CS1320 Camera Access Controller Thank you for purchasing GV-CS1320 Camera Access Controller. This guide is designed to assist the new user in getting immediate results from the controllers.
More informationQuick Start Guide. GV-Video Server
Quick Start Guide GV-Video Server Thank you for purchasing GV-Video Server. This guide is designed to assist the new user in getting immediate results from the GV-Video Server. For advanced information
More informationGV-AS200 Controller. Hardware Installation Guide
GV-AS200 Controller Hardware Installation Guide Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. 2008 GeoVision, Inc.
More informationInstruction Manual. Vogue. Security. Technology. Innovation 2013-V01
Instruction Manual DH16A-60DTE Model 60 with plastic keypad, stand alone access control DH16A-60DTQE Model 60 with plastic keypad, networked access control 2013-V01 Security Technology Vogue Innovation
More informationCM-110SK Standalone Keypad Installation Instructions
CM-0SK Standalone Keypad Installation Instructions. Packing List Qty Name Remarks 2 2 Keypad User manual Screwdriver Wall plugs Self-tapping screws Torx screw 0.8 x 2.4 Φ(20 mm 60 mm) 0.24 x.2 Φ (6 mm
More informationQuick Start Guide. GV-Video Server
Quick Start Guide GV-Video Server Thank you for purchasing GV-Video Server. This guide is designed to assist new users in getting immediate results from the GV-Video Server. For advanced information on
More informationQuick Start Guide. ProBio & ProFAC + ZKBioSecurity 3.0
Quick Start Guide ProBio & ProFAC + ZKBioSecurity 3.0 CONTENT 1 Safety Precautions...2 On Using Face Recognition Device...3 Device Overview...5 Product Dimensions & Installation...6 Power Connection...7
More informationTEC100 USER/INSTALLER MANUAL V2.0 REV. 03/2018
TEC100 USER/INSTALLER MANUAL V2.0 REV. 03/2018 00. CONTT 01. SAFETY INSTRUCTIONS INDEX 01. SAFETY INSTRUCTIONS STANDARDS TO FOLLOW 02. PRODUCT PRODUCT PROFILE TECHNICAL PARAMETERS 03. INSTALLATION PRODUCT
More informationVIDI-AC-2CS Access Controller/ Reader
VIDI-AC-2CS Access Controller/ Reader User Manual CONTENTS INTRODUCTION 2 INSTALLATION.4 STANDALONE MODE 6 CONTROLLER MODE.11 WIEGAND READER MODE.. 13 ADVANCE APPLICATION..14 1 INTRODUCTION The VIDI-AC-2CS
More informationInstallation Instructions. i-net Access Control Units. Part Code: IA-PCB IA-ACB IA-ACU IA-KIT
Installation Instructions i-net Access Control Units Part Code: IA-PCB IA-ACB IA-ACU IA-KIT This device is configured for DHCP. Identity Access software will find this device, go to setup and controller,
More informationACTpro 1500 Single Door IP Controller
ACTpro 1500 Single Door IP Controller ACTpro 1520 Single Door IP Controller with 12 V DC 2 amp power supply. Operating & Installation Instructions 18-00085 Issue 2 This manual refers to the ACTpro 1500
More informationSF200. Installation Guide & Quick Start Guide. 2 TFT AC Terminal Version: 1.0 Date: June 2014
SF200 Installation Guide & Quick Start Guide 2 TFT AC Terminal Version: 1.0 Date: June 2014 All design and specification declared are subject to change without notice in advance. Contents Safety Precautions
More informationDG-800 Stand-Alone Proximity Reader Instruction Manual
DG-800 Stand-Alone Proximity Reader Instruction Manual I. Features 1. Memory volume up to 1000+10 proximity cards/tokens and PINs with the programming time up to 0.5 seconds. 2. Access modes: a. Only Proximity
More informationINSTALLATION INSTRUCTIONS 920P EntryCheck TM
801 Avenida Acaso, Camarillo, Ca. 93012 (805) 494-0622 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS 920P EntryCheck TM The EntryCheck 920P Indoor/Outdoor Keypad is a surface-mount
More informationTwo-door Access Controller
Two-door Access Controller Quick Start Guide V1.0.0 Preface Overview This document elaborates on structure, installation, interface and wiring of two-door access controller. Symbol Definition The following
More informationW3-M. Metal waterproof standalone access control/reader. User Manual
W3M Metal waterproof standalone access control/reader User Manual Name Digital Keypad W3M User Manual Screw driver Rubber bungs Selftapping screws Diode 1. Packing List Quantity 1 1 1 4 4 1 Remark 6*27mm,
More informationIPassan Installation guide
IPassan Installation guide 1 Content 1 Overview... 3 1.1 Features... 3 1.2 Hardware... 3 1.2.1 s... 3 1.2.2 Extra modules... 5 1.3 IPassan manager... 7 2 Installation... 7 2.1... 8 2.1.1 Power supply...
More informationINSTALLATION GUIDE. InBio Pro Series Access Control Panels. Date: June, 2016 Version: 1.3
INSTALLATION GUIDE InBio Pro Series Access Control Panels Date: June, 2016 Version: 1.3 2 What s in the Box 2 Screws & Anchors 2 Screwdriver 4 Diode CONTENT Contents What s in the Box...2 Optional accessories...4
More informationPegasus Equipments Export Limited. Local Contact:
Pegasus Equipments Export Limited Add: #31G, Haiyige, Scienway Palace Science & Technology Industrial Park Shenzhen, China. Tel: +86 755 2658 3464 +86 755 2658 3596 Fax: +86 755 8611 0167 web: www.pegasusexport.com
More informationUser Manual. PCKeypad Wireless Keypad
User Manual PCKeypad Wireless Keypad Description The PCKeypad is a wireless keypad with a PentaCODE transmitter built-in. It works with all of Elsema s PCR series receivers. The installer has the option
More informationQuick Installation Guide MAC1000/MAC1000SR STANDALONE BIOMETRIC CONTROLLER
MAC1000/MAC1000SR STANDALONE BIOMETRIC CONTROLLER Table of contents 1 PRODUCT INTRODUCTION... 2 1.1 NAME AND FUNCTION OF EACH PART... 2 1.2 CABLE COLOR TABLE... 4 1.3 CABLE SELECTION... 6 2 IDENTIFYING
More informationEZ-TAG2 Manual_Layout 5 11/12/ :14 Page 1 U S E R M A N UAL
EZ-TAG2 Manual_Layout 5 11/12/2012 09:14 Page 1 USER MANUAL EZ-TAG2 Manual_Layout 5 11/12/2012 09:14 Page 2 Contents EZ-TAG2 and Back Plate 1 x Security Torx Key 4 x Screws and raw plugs 1 x Marking out
More informationGV-RK1352 and GV-R1352 Card Reader
GV-RK1352 and GV-R1352 Card Reader The GV-RK1352 and GV-R1352 are card readers designed to recognize identifications cards. GV-RK1352 comes with keypad, allowing it to also recognize PIN codes. Featured
More informationW3-H Waterproof Keypad/Reader/Controller
W3-H Waterproof Keypad/Reader/Controller User Manual 1. Packing list Name Quantity Digital Keypad W3-H 1 User Manual 1 Screw Driver Rubber Bungs Self Tapping Screws Diode 1 4 4 1 Manager Card 2 Remark
More informationPartizan PAB-FC2. Fingerprint scan time Fingerprint identification time. <0.5 s < % <0.0198% Ingress protection rating
1. Features & Technical Parameters 1.1 Features: Partizan PAB-FC2 Metal vandalproof housing Secure and reliable biometric fingerprint recognition Simple for using, wiring can be done by a user without
More informationAIM- DAC System. DAC844 User Manual. Anviz Global Inc
DAC844 User Manual 1 Notice and Disclaimer This manual s sole purpose is to assist installers and/or users in the safe and efficient installation and usage of the system and/or product, and/or software
More informationFingerprint Access Standalone User s Manual
Fingerprint Access Standalone User s Manual V1.1.1 1 Table of Contents 1 Overview... 1 2 Device Structure and Installation... 2 2.1 Device Structure... 2 2.2 Device Installation... 3 3 System Structure...
More informationClick Save to return to the main Setup screen.
ON-SITE Setup Guide Thank you for purchasing the ON-SITE. This guide will assist you in the setup of the system. You can call for FREE technical support to get help anytime at 757-258-0910. Please note,
More informationPortals 14 What is a portal? 14 Hardware 15 RS232 to RS USB to RS TCP/IP to RS Add a Serial Portal 16 Add a Network portal 16
PROS LITE User Manual Version 2.0.0 www.visual-plus.com Table of Contents Getting Started 5 Starting PROS Lite 5 Create a Portal 5 Adding a control panel 6 Adding a user 7 Upload users to a controller
More informationFingerprint Access Control F1. User Manual
Fingerprint Access Control F1 User Manual 1. Introduction F1 is a metal shell standalone fingerprint access control, using the America Atmel s MCU, with precise electron circuit and good productive technology.
More informationRD-SR2 ACCESS SECURITY PRODUCTS LTD. Proximity Card Reader with Remote Control. User Manual
RD-SR2 Proximity Card Reader with Remote Control User Manual INTRODUCTION The RD-SR2 is a compact, weather resistant multi-function card reader that can be used as a standalone programmable access control
More information7612 Programming Instructions
7612 Programming Instructions Built-in Proximity reader Read Range 65mm odulation ASK at 125kHz Compatible Cards ALL 26-Bit EM Cards 7612 is a vandal resistant proximity card and keypad access control
More informationIBA-7612 Programming Instructions
IBA-7612 Programming Instructions Built-in Proximity reader Read Range 65mm odulation ASK at 125kHz Compatible Cards ALL 26-Bit EM Cards IBA-7612 is a vandal resistant proximity card and keypad access
More informationINSTALLATION INSTRUCTIONS 920 EntryCheck TM
801 Avenida Acaso, Camarillo, Ca. 93012 (805) 494-0622 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS 920 EntryCheck TM The EntryCheck 920 Indoor/Outdoor Keypad is a surface-mount
More informationUser Manual. Split access control with intelligent secured power supply.
User Manual Split access control with intelligent secured power supply. Contents. Introduction, features and specifications. Installation and Wiring Diagram 3. Manager Card Operation 4. User Settings 5.
More informationUser Manual. Before using this device, read and follow all instructions for safety
User Manual Before using this device, read and follow all instructions for safety Copyrightc 2014 KJTECH Co., Ltd. All rights reserved. It is provided for informational purposes only in this manual. All
More informationWiring Guide. EP.NMiNi 2. Version 1.04 Last Updated:
Wiring Guide EP.NMiNi 2 Version 1.04 Last Updated: 31-01-2013 Before you begin Technical Support If you cannot find the answer to your question in this manual or in the Help files, we recommend you contact
More informationC5S120 Installation and Connection Guide
C5S120 Installation and Connection Guide Version: V1.1 1. Cautions Please note the following cautions. Mis-operation may lead to personal injury or equipment failure: 1) Do not energize the system before
More informationTechnical Manual Nova: Cabinet Security Management System (CSMS)
Technical Manual Nova: Cabinet Security Management System (CSMS) KP_nova_TM_160501_EN 1 Publication May, 2016, Keyprocessor BV Paasheuvelweg 20 1105BJ Amsterdam, The Netherlands www.keyprocessor.com/nova
More informationicam7000s SERIES HARDWARE GUIDE Packing List CONTACTLESS CARD READER RECESS MOUNT (Optional) ISO/ANSI COMPLIANT EASY INSTALLATION What s in the Box
icam7000s SERIES HARDWARE GUIDE ADVANCED MULTIFACTOR BIOMETRIC IRIS READER VERSION 1.0 icam7000s-t (Titanium Color) icam7000s-b (Black Color) DUAL IRIS ISO/ANSI COMPLIANT FACE CAMERA EASY INSTALLATION
More informationInstallation & User Manual
Contents Installation Instructions 3 Installation Diagrams 4 System Overview 6 Wiring Diagrams 8 Network Diagrams 9 Operation Instructions Fingerprint Enrollment 12 21 Wi-Enterprise Controller www.transmittersolutionssmart.com
More informationFace & Fingerprint Recognition Product
Realand Bio Co., LTD. Face & Fingerprint Recognition Product Hardware User Manual PRO6. Date: June 2016 Product Specification PC Software Version Cloud Based Version LCD Display 2.8 inch TFT Color Screen
More informationQuick Start Guide. GV-AS / EV Controller
Quick Start Guide GV-AS / EV Controller Thank you for purchasing GV-AS / EV Controller (GV-AS100 / AS110 / AS120 / AS210 / AS400 / AS410 / AS810 and GV-EV48). This guide is designed to assist the new user
More informationP4 P5 P6. Security trigger signal 2 Purple Security trigger signal Output 6 Thin Blue Wiegand DAT: 1 Input
SOYAL ACCESS CONTROL SYSTEM AR- (E) / (EF) V Contents AR- (EF):Fingerprint Products User Guide Terminal Cables Tools DO AR- (E) Or MT P P P P P P P P P P P P Water proof Strip Optional Products User Guide
More informationBiometrics Device Access controller Fingerprint & Finger Vein V Connector Table () Cable: P Wire Application Anti-Tamper Switch Wire Color Red Orange
SOYAL ACCESS CONTROL SYSTEM AR- (EF-V) / (EV-V) V Contents AR- (EF-V):Fingerprint Products User Guide Terminal Cables Tools Optional P P P AR- (EV-V):Vein P P P AR-RB Products User Guide Terminal Cables
More informationInstallation and User Manual
S2 Metal Waterproof Access Control Unit Installation and User Manual (Ness Part No. 101-082) 1 Introduction Ness S2 is an advanced, waterproof (IP65 rated) proximity and PIN Access Controller. S2 can support
More informationDOLXFD1000B. Waterproof Access Control/Reader
DOLXFD1000B Waterproof Access Control/Reader INTRODUCTION The DOLXFD1000B is a single- entry multi-function Access Controller with integrated keypad and card reader. It is designed and manufactured to
More informationInstallation & User Manual V2.08
YOUR SECURITY IS OUR PRIORITY Other products from GSD Contents Installation Instructions Installation Diagrams System Overview Wiring Diagrams Network Diagrams Operation Instructions Fingerprint Enrollment
More informationPoE IEEE802.3at MIFARE MHz. EM 125 KHz
ACT-457A 5.7 RISC-based RFID Panel PC Features PoE IEEE802.3at 5.7 TFT touch color screen, full interface display, all operations can be done directly on the touch screen Integrated with RMI Alchemy AU1250
More informationCP150B Vandal & Weather Resistant Keypad Security Systems
Vandal & Weather Resistant Keypad Security Systems EN Security System CP150B - Vandal & Weather Resistant Keypad The CP150B keypad provides alarm and or access control functionality when used on selected
More informationCRC220 and CRC221 INSTALLATION GUIDE. REF No.: DOC0014 ISSUE: 09
CRC220 and CRC221 INSTALLATION GUIDE REF No.: DOC0014 ISSUE: 09 30th July 2015 2 Contents CRC220 & CRC221 INSTALLATION GUIDE 1. Scope 1-1 2. Introduction 2-1 2.1 Features 2-1 2.1.1. PCB Features 2-1 2.1.2.
More informationSmart HUB - HUB to expand one Master Controller s RS-485 port to 8 RS-485 ports - Use 12VDC power
Hardware Overview - SmartKey Master Controller - Smart HUB - - RFID Readers Master Controller HUB Features: RFID Readers SmartKey Master Controller - 1MB internal memory (2MB optional), can hold up to
More informationStandalone Access Control
Standalone Access Control BELL_A BELL_B D0 D1 D_in(LED) Open (BZ) COM ALARM- Light Green Pink Red Black Green White Brown Yellow Blue Purple Orange Grey Door Bell DC 12V Power Green White Reader Red Black
More informationEZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY
EZTAG PROXIMITY AND KEYPAD DOOR ENTRY USER MANUAL www.espuk.com EZTAG Manual_Layout.indd 8//06 5:8:0 System Components Proximity and Reader 0 x Proximity Tags x Hex Key x Plastic wall plug x Countersunk
More information791/793 Easy Entry Keypads
791/793 Easy Entry Keypads Description The DMP 791 and 793 Easy Entry LCD Keypads are the industry s first burglary/fire keypads with integrated access control capability. Each keypad provides three 2-button
More informationXT200 Intelligent Network Router
XT200 Intelligent Network Router Installation Manual V0103 SYRIS Technology Corporation 12F, NO.12 Sec. 1, Taijunggang Rd. Taichung city, Taiwan(403) TEL: 04-2207-8888 FAX: 04-2207-9999 Email:service@syris.com
More informationINSTALLATION GUIDE 2.4 Inch TFT Terminal Time Attendance & Access Control
STALLATION GUIDE.4 Inch TFT Terminal Time Attendance & Access Control Optional accessories Safety Precautions The following precautions are to keep user s safe and prevent any damage. Please read carefully
More informationQUICK START GUIDE. 2.4 Inch Finger Vein Terminal Time Attendance & Access Control
QUICK START GUIDE 2.4 Inch Finger Vein Terminal Time Attendance & Access Control Version: 1.0 Date: Apr., 2017 1 2.4-Inch TFT LCD USB Storage Device Port Keypad& Card Reader Doorbell & LED Indicator Fingerprint
More informationSpecifications: Features:
ROFU Features: Applicable card mode EM Card / Key Fob 1 Administrator and 200 Users 200 Proximity Cards / Key fobs Access Modes:Use Bluetooth smartphone or Card / Key fob to access Built-in Tamper alarm
More informationE5 Series. Installation and Setup Guide
801 Avenida Acaso, Camarillo, Ca. 90312 (805) 494-0622 Fax: (805) 494-8861 www.sdcsecurity.com E-mail: service@sdcsecurity.com E5 Series Installation and Setup Guide P:\Installation Instructions\Access
More informationEL-ST100 KEYPAD CONTROLLER
WIRING DIAGRAM EL-ST100 KEYPAD CONTROLLER WEATHER-PROOF STANDALONE ACCESS CONTROLLER WITH KEYPAD & PROXIMITY TECHNOLOGY Programming and Installation Manual NOTE: www.elock2u.com ICT at work! Version 3.6
More informationON-LINE PROXIMTY ACCESS CONTROLLER OPERATION MANUAL MODEL: HA3035 VERSION: 2.9x
ON-LINE PROXIMTY ACCESS CONTROLLER OPERATION MANUAL MODEL: HA05 VERSION: 2.9x HEART ENTERPRISE CO. LTD. HEART ENTERPRISE CO., LTD. 0 Chapter I Introduction. Introduction 5.2 Features 5. Specification 6.
More information1. Product Specification
1. Product Specification Item Specification Voltage 12VDC +10%, Current 1.2A Lock Relay 12VDC/2A Environmental Temperature working:0 ~45 ; storage:-10 ~55 Relative humidity working:40%~90%rh; Card Capacity
More informationAtlas ATLAS INSTALLATION MANUAL SECTIONS INDEX EQUIPMENT / MAIN FUNCTIONS TECHNICAL FEATURES ATLAS: PIN IN/OUT / GENERAL VIEW
Atlas INSTALLATION MANUAL SECTIONS INDEX EQUIPMENT / MAIN FUNCTIONS 1 TECHNICAL FEATURES 2 : PIN IN/OUT / GENERAL VIEW 3 : IP ADDRESS CONFIGURATION 4 WARNINGS 5 SETTING TABLES 6 : CONNECTIONS EXAMPLES
More informationInstallation guide for PR602LCD type access controller
Roger Access Control System Installation guide for PR602LCD type access controller Firmware version: 1.18.6 or newer Document version: Rev. K 2016 ROGER sp. z o.o. sp.k. All rights reserved. This document
More informationinstallation quick guide integrated access control & environmental monitoring
installation quick guide integrated access control & environmental monitoring Introduction This Installation Quick Guide is suitable for standard wallmountable AX300 controllers. Illustrative technical
More informationREX F-0-9 Standalone or Access Controller
REX F-0-9 Standalone or Access Controller Power supply The controller need s external power supply to operate. The Spider W40 power supply is sufficient to power two controllers and two 12V electric strikes
More informationINSTALLATION SHEET 791 and 793 Easy Entry Keypads
INSTALLATION SHEET 791 and 793 Easy Entry Keypads Description The DMP 791 and 793 Easy Entry LCD Keypads are the industry s first burglary/fire keypads with integrated access control capability. Each keypad
More informationBuilding Technologies. Access Control SiPass networked - simple & networkable for everyday use
Building Technologies Access Control SiPass networked - simple & networkable for everyday use SiPass networked Innovative access control SiPass networked is part of the SiPass product range for use in
More informationWiring Guide EP.NMINI. Version 1.02 Last Updated:
Wiring Guide EP.NMINI Version 1.02 Last Updated: 14-10-2014 1 Note: See http://www.entrypass.net/ for updates, revisions, and download the latest installation manual There are currently 2 version of EntryPass
More information2000 Series e/em Style Keypad Installation and Programming Manual
2000 Series e/em Style Keypad Installation and Programming Manual Document Number: 6054022 Revision: 0 Date: 12/21/06 Table of Contents Table of Contents Section 1: Introduction... 6 1 Product Description...6
More informationPW6000 Modular Access Control System PW6000 Intelligent Controllers and Modules
Modular Access Control System The next generation of the PW-Series family improves on the existing PW technology to offer superior features and benefits. The PW-Series Modular Control System is an advanced
More informationVICON ACCESS CONTROL CONTROLLERS
VICON ACCESS CONTROL CONTROLLERS Also available in white Over-the-Door Controller Master Controller Multi-Door Kit Elevator/IO Controller Product at a Glance The Vicon Access Control (VAX) system consists
More informationT&A Fingerprint machine
Installation Guide series 2 V1.0 T&A Fingerprint machine Installation Guide series 2 Content 1. Before Installing... 1 1.1 Notice... 1 1.2 View of Operation Panel... 3 1.3 View of Power and Comm. Port...
More informationOperation Manual. Thank you for selecting Keyking products. Please read this manual thoroughly before use. Models: TC418/419 Standalone Controller
Operation Manual Thank you for selecting Keyking products. Please read this manual thoroughly before use. Models: TC418/419 Standalone Controller KEYKING GROUP Index Chapter 1: Summay...3 1.1 Outline...3
More informationRBR-SB-KTZ001 LAR 2. User Manual
RBR-SB-KTZ001 LAR 2 User Manual INTRODUCTION KTZ001 is a compact, waterproof stand-alone programmable access control system that provides proximity entry for up to 2000 users. Read both EM and HID card.
More informationInstallation Guide for PR311SE and PR311SE-BK v1.0 Access Controllers Rev. B
Installation Guide for PR311SE and PR311SE-BK v1.0 Access Controllers Rev. B Introduction This document contains minimum information that is necessary to properly install the device and to perform its
More information