1 NVGate V9.00 RELEASE NOTE Teamwork 1

2 Summary Teamwork... 1 Summary... 2 Introduction... 3 Overview... 3 Connections... 4 Connection dialog... 4 Visibility of analyzers... 5 Connection to the analyzer... 5 Ethernet IP management... 5 DHCP server from the analyzer... 6 Firmware update... 6 Change analyzer name... 6 Connect to multiple analyzers at a time (Teamwork only)... 7 Impact test... 9 Damping ratio marker... 9 Component, Node and Direction on trace labels Table format on Excel reports Automatic reports Print All Results Considerations for All windows and All results(x) automatic report Batch measurement Data selection Signals management Run Up/Down Waterfalls Oversampled waterfall collections Miscellaneous Link all cursors in one click Input Label reduction Input Label reduction Toolkit Fixed issues

3 Introduction The 9 th main version of NVGate is available since January This major release of the OROS 3- Series analyzer s software platform supports the latest Teamwork instrument generation and features improvements regarding IP connection, hard drive management, impact test, run up/down waterfall and other ergonomics. The present release note describes the content of V9.00 and the first bundle V9.10, with operating details. Overview NVGate V9.00 is compatible with all OROS OR36/38 V3 Teamwork series analyzers whatever their date of release and version. Depending on the hardware options and version, some instrument features may or may not be available. This software release offers different improvements concerning: Connections Simple and easy connection to the analyzer Connection thru the network Change IP addresses DHCP server from the analyzer Firmware update Manage analyzers identifiers Connect to multiple analyzers (Teamwork only) Software environment management Impact test Damping ratio on peak and max markers Component, Node and Direction on trace labels Orientation of marker-table on Excel reports Reports Automatic print all results Batch reports Signals manager Enriched recordings properties Managed distributed signals Selectable project for downloaded recordings Run Up/Down waterfalls Miscellaneous Toolkit Colormap colored floor Tach centered on block center Oversampled waterfall collections Windows 8 and 8.1 compatibility Windows XP compatibility warning Spare units Inputs label displayed only if different from Input x One click to link all cursors MatDrive with MATLAB V14 Printing commands Grouped sequences of commands 3

4 Connections NVGate V9.00 features a dialog box dedicated to the connection and update of the analyzer(s). This dialog is displayed in place of the choice between connected and office mode. Connection dialog This dialog gathers in a unique list the office mode and the list of visible analyzers for connected mode. It is possible to select one or multiple analyzers 1 or the office mode Model(s) selection List of visible analyzers and office Details and modification of the highlighted analyzer Connection issue notification The dialog contains multiple area and commands. Model list area showss the available analyzer and the office mode. Details area shows the information related to the highlighted analyzer. Analyzer may be highlighted by clicking on the corresponding row out of the selection chek box. Issue notification. This area appears at the bottom of the Model list when an issue block the start of NVGate (Start button is disabled) Refresh button rescans the network and updates model column. Resync button relaunches the clock synchronization between analyzers for cascade purposes. Start button launches NVGate with the selected model; Office, analyzers multiple Teamwork Connected, Multiple 1 Teamwork instruments only 4

5 Visibility of analyzers Visible analyzers are the OROS 3-Series (V1, V2 and now V3 2 ) connected on the same network as the PC. The connection between the PC and the visible analyzer(s) must be on the same logical network (i.e.: A company LAN with network switches or cascade of Teamwork analyzers). Analyzers already running an NVGate session are not visible in this dialog. Analyzers with the same IP address are visible in this dialog. IP must be changed to different ones to allow starting NVGate on multiple analyzers. Name Chain, and Status columns are updated periodically. NB: Internet Routers are supported by Teamwork analyzers (V3) only by specifying the analyzer IP address in the command line of NVGate. Connection to the analyzer To connect to your analyzer, select the corresponding check box in the Model column. To start NVGate with the Office mode (Running on the PC with a dongle or the analyzer as a dongle) select the Office model. Just like previous NVGate versions: The Office model is automatically selected if there is no visible analyzer. In the presence of visible analyzers, NVGate will select the first connected one in the list according to the following priority: 1. Firmware compatibility 2. IP compatibility 3. Discovery date The Start button will remain disabled until the following criteria are fulfilled: At least one model is selected If it is one or plural connected one o The corresponding model firmware are up to date. o The IP address of the selected models are compatible with the PC one NB: it is not possible to mix Office and Connected models Ethernet IP management IP address management has been dramatically improved with NVGate V9.0. This is particularly true by the visibility of all connected analyzers whatever the firmware version, IP addresses compatibility and duplication. Both PC IP@ and highlighted analyzer are visible in the detail area. You can change the analyzer IP settings by clicking on the analyzer IP link. 2 Teamwork (V3 analyzer) are not compatible with Windows XP 5

6 You can update the analyzer IP manually but the most substantial and easy way to solve IP address conflicts is to use the Generate Automatically button. This method will take in account all IP addresses in the logical network to avoid any conflict; even the ones not visible from this dialog. DHCP server from the analyzer This feature allows the analyzer to provide the PC IP address. This is available from V3 Teamwork analyzers only. When a V3 analyzer is set as a DHCP server, it will update your PC IP address when this one is set as Get automatically IP address. This configuration allows immediate connection of PC configured for company network. The DHCP server of the analyzer is Non authoritative, this means that when the analyzer is connected to a local network it will not act when an Authoritative one exists. Firmware update The firmware can be updated on demand. The Connection dialog detects the not-up-to-date firmware. Simply click in the firmware link: Not up-to-date to enter the firmware update process. A monitoring window is opened during the update. At the end if the update is successful, the window background goes to green. In case of unsuccessful, it goes to red. Change analyzer name While using multiple analyzers together, it is useful to set easily the identification of each chassis. Click on the Name Link to update the highlighted analyzer identifiers. Long name is used to identify the system in the software installation and properties dialogs Short name are used in NVGate settings and trace/result management. 6

7 Connect to multiple analyzers at a time (Teamwork only) NVGate V9.00 allows running multiple Teamwork instruments from a unique NVGate instance at a time. This allows cascaded or distributed configuration of OR36/38 V3. The same program (NVGate.exe) and connection dialog is used. After launching NVGate you get the visible analyzer list in the connection dialog. Chain 1 Synch Ethernet switch Chain 2 The Chain column shows the possible analyzers combination. The first digit is for the chain Id. The second one is for the analyzer position in the said chain. A chain is defined by a group of consecutive daisy-chained analyzers with a clock synchronization line in between. A unique analyzer is considered as a chain. The Status column shows the synchronization status. Synchronized means the analyzers sampling clocks are in phase (< 20 khz). It is possible to start NVGate before the synchronization process is finished; NVGate interface will wait for the achievement. Single chain analyzers are automatically synchronized. If the synchronization cannot achieve (ex. cabling change) you can restart the process with the ReSync button 7

8 While launched on multiple Teamwork analyzers, the NVGate interface remains exactly the same as with one analyzer. All input identifiers are enhanced with their hosting systems short name. This is passed on to the results, legends, marker tables, etc.. Plug-ins availability NVGate V9.10 running on multiple analyzers supports the following ASB items: Full front-end: Universal inputs, Ext. Synch, DC, Out, CAN 3, ICP, TEDS Recorder up to 256 channels FFT1 to 4 up to 256 channels per FFT FFTDiag tools Events/Triggers Filters Time windows Next bundles will provide additional plug-in in cascaded modes: Tachometers, Waterfall, 1/Octave, Synchronous order and Time domain analysis. 3 CAN bus is supported on Master analyzer only 8

9 Impact test The impact/bump test operation the following functions: Damping ratio marker continues to be improved with NVGate and 3-Series analyzers with A damping calculation is now available with the peak and max markers. Calculation method The calculation is based on the Half-power-band-width method, where DR is the damping ratio: ω = peak _ ω R = peakfrequency 1 amplitude ) 2 ω DR = 2ω R Operations The calculation of the damping factor is activated through the marker properties or preferences. When it is activated an additional column is added in the corresponding marker table. The marker table can be saved in an MS Office document or simply copied and pasted. Warning, using nonhomogeneous weighting windows (i.e.: equivalent noise bandwidths are not the same) on FRF channels leads to incorrect peak interpolation and damping results. 9

10 Component, Node and Direction on trace labels In order to simplify the trace identifications in applications that manage many measurement points (structural dynamics, Roving impact hammer) the content of the front-end identification settings are inserted in the trace labels. The trace labels display the Component, Node and Direction when the corresponding setting is different from its default value: Component = None Node = 0 Direction = Scalar This applies individually, setting by setting and is independent for each channel. Table format on Excel reports Adding marker or inputs tables in an Excel report is a popular function of the NVGate report mode. It is now possible to define how the NVGate table will be arranged in the Excel sheet. In the following examples we have 3 FRFs (1 hammer, 1 tri-axis accelerometer) per measurement point. We measure the highest peak amplitude, frequency and damping ratio on all FRFs at each measurement point. 10

11 The table format is governed by attributes in the NVGate Tag in the report file. After the drag & drop of the table in the report file, you can insert the following attributes 4 Flattened table The first arrangement allows transposing the table in one unique line. This is useful with the autoeach acquisition. increment function when you are using multi-line table (ex: multiple traces) for Regular report will provide this: By adding the TableStyle=Flat to the NVGate tag: [NVGate MarkerTable FRFs FRF "MarkerType=Peaks" "TableStyle=Flat"]Table[/] The result is changed as follow: Select columns This arrangement allows selecting which columns to be printed in the report. For example if you do not need the interpolation information add the "TableColumns= " to the NVGate tag: [NVGate MarkerTable FRFs FRF "MarkerType=Peaks" "TableStyle=Flat" "TableColumns=1,2,4,5,7,8,9 ]Table[/] Assuming the column 3 and 6 are for the interpolation indicator, the table will look at: 4 To be inserted between quotes inside the tag brackets. 11

12 Automatic reports With NVGate V9.00 the automatic report functions are included for free. These reporting modes supplement the Print all windows one. On the left side of the report tab, the automatic report functions are made available in the report tab group has been added: Automatic report. It features 2 additional fully automated report generations and a batch function for multiple measurements reports: The All results (single & compare) as well as the Measurements batch. Print All Results These functions allow printing all channel results in a comprehensive report, without requiring the setup of any template. That generates automatically a report with all the acquired and analyzed data. It is useful for multianalysis and multichannel measurements report. Basically all existing results (computed by NVGate / Analyzer) having the same type as the displayed windows will be printed in this format. The user selects the type of result to be printed by displaying at least one of the results in one layout of the current setup. Print all results (single) The function scans each layout to get the plug-in (FFTx, SOAx, OCT ) and the result type (Spectrum, RMS, trigger block ) of the first trace in each window (referencee trace). Then it plots the same result type for each channel of the corresponding plug-in. As an example working with inputs 1 to 8 connected to FFT and recorder with the following layouts: Layout 1 Window 1: Front-end RMS input 1 to 8 Window 2: Recorded signal input 4 and 8 Layout 2 Window 1: FFT Average spectrum input 1 Window 2: FFT Trigger bloc input 1 The All results automatic report will print the following graphs: Layout 1: Window 1 RMS level: Inputs 1 to 8 (8 plots) Layout 1: Window 2 Recorded signal: inputs 1 to 8 (8 plots) Layout 2: Window 1 FFT avg. spectra: inputs 1 to 8 (8 plots) Layout 2: Window 2 FFT Trigger bloc: inputs 1 to 8 (8 plots) The format of the reference trace is applied to each corresponding plot. In the case of cross function the reference trace will be used as the reference for each result (FRF, Coherence, etc.) Print all results (single) = Note: the report format is the same as the All windows one 12

13 Print all results (compare) The compare version of the print all result function allows comparing every measured result with a reference one. It is useful to check variations along a structure or a shaft for example. In this case the reference trace will remain displayed while the other results are plotted within the same graph. This method scans the result exactly as the single version except it shows 2 traces per graph in the report. Print all results (compare) = Considerations for All windows and All results(x) automatic report The report generation is based on the content of the saved workbook. If your workbook has been changed without saving it (CTRL+D or Save project) the content of the report file will reflect the last saved workbook content. The report is based on predefined templates. You may adapt these templates in order to change contents (ex: your company logo, or add specific setting or marker).the original templates are located in the NVGate installation directory \ Template library. Copy the corresponding folder (All windows or All results) from this directory and past it in the NVGate Data\ template library. The pasted file will be taken in account instead of the original ones. The report generated with these methods may be updated form the NVGate GUI: Open the report file, select it from the report\active file group in NVGate and press Refresh button. Batch measurement This function allows printing all the saved results of a set of similar measurements. It fits ideally the process of measurement campaigns, prototype fine tuning loops, machinery evolution or diagnostics and repairs. The batch measurement report is also used to format a set of measurements with the same presentation layouts. The automatic report generation inputs are: A set of saved measurements A reference layouts A Word /Excel template The first operation consists of setting up one measurement in order to adjust the graphs format. Select one measurement and modify/enrich the layouts: graphs, scales, markers, windows/layout name, comments and properties. Click on Home/Start/Edit measurement button and save the edited measurement. Secondly, create a Word template to fit the edited measurement. See the [Reference manual Vol. 3 Reports, Tools & ribbons] for instructions. Third, select the measurements to be printed. Click on the Report/Automatic reports/measurement batch button. The batch report selection dialog is showed (NB: it may take a few second to display if your project manager contains lot of projects/measurements). 13

14 This Dialog is divided in 3 areas, one for each input parameters and one for the output files 1. The selection of measurements to be printed selection. 2. The format do be applied on the processed measurement data (Layouts of a measurement from the Project manager) 3. The Word templatee to used for each generated report 4. The output options; directory and file name. Last, print the reports. By selecting Save layouts in measurements each processed measurement will be updatedd with the format layouts. When these measurements are edited, the graph presentation is then homogeneous and corresponds to the report contents. By selecting Discard layouts from measurements the measurement layout are not modified. Batch measurement = + Data selection The measurements selection is helped by a search engine which filters the project manager measurements according to their properties. The measurement frame reflects the project manager content. It is possible to expand or collapse the projects. The displayed measurements correspond to the following criteria: One of the active properties matches the search text, The measurement is already selected. 14

15 It is then possible to make mixed selection from various criteria. The properties are activated/deactivated (i.e. included in the search process) by selecting it with the button at the right of the search text. It is also possible to mask/show the properties columns by right clicking on the header. The column order can be changed by drag and dropping one column to its new location. Enter the searched text here Click here to sort ascend/descend according to this column Click heree to activate or dethe activate searched columns Right click heree to mask/show the column. The measurements are sorted by column content (alphanumerical sort) by left clicking on the column header. 15

16 Signals management To accompany the teamwork generation, NVGate signal management has been improved. It is now necessary to provide signal storage devices and used hardware for single and multi-hardware acquisitions. 2 dialog have been changed; the signal properties and the disk manager. Signal properties The properties of recorded signals have been enriched with location and traceability. Analyzer(s) used for record Disk(s) used for record Availability of data for download The analyzer(s) whichh have been used to record the signal are memorized in the column Acquisition Front-end. It is the easy to identify records that may be altered by a faulty input. Same thing regardingg the used (Mobi-) disks. These information are memorized with the measurement itself. They are available even if the analyzer or the disk is not connected. The Signal on disk indicates the presence of record file on the connected disks: Yes/No or a question mark when the disk is not connected. 16

17 Disk manager The disk management has also been adjusted allowing the management of multi-disk measurements. This dialog is accessible through the Home/Disk ribbon group. Both Manage and Download button open it. The dialog shows all records which have at least one file on the active disk(s): On analyzer(s) or on PC USB. The preselection buttons have been synthetized in 3 categories: All / None: for backup or disk cleaning. 17

18 Downloadable: Select records which have corresponding project & measurement in the Project Manager Orphans: Select records which haven t any corresponding project & measurement in the Project Manager NB: Preselection buttons do not select partial records, i.e. one or more disks are not connected. Use manual selection to download an incomplete record. Warning this is a definitive action. It will be impossible to add missing files later. The Target choice allows choosing the download destination: Automatic: add each signal file in the Project/Measurement used for its acquisition. Note that records without Project/Measurement correspondence in the Project manager will be added in the current project. Project: add the signal files in the selected project regardless their original project. 18

19 Run Up/Down Waterfalls The waterfall and profile provide new capabilities that improve readability and accuracy. Tachometer centered on FFT/SOA blocks This allows centering tachometer speed at the center of the FFT/SOA triggerr block(s). It is useful with long trigger blocks (High resolution analyses) to perfectly match the actual data with the order cursor or section. With classical tach: The RPM is collected at the end of the analysis block RPM 3 2 Block 1 Block 2 Block 3 1 Actual order N Cursor at order N This situation leads to an offset in the waterfall calculation of the orders (cursors, sections). For a run up, as the angular speed is over evaluated, the order calculation is lower than the actual ones. With centered tach: The RPM is calculated as the average speed during the block duration to be synchronized with the analyzed data. RPM 3 2 Block 1 Block 2 Block 3 1 Actual order N Cursor at order N 19

20 With the centered tachometer, the orders calculations match more accurately the actual orders in waterfall. The computation of the angular speed takes in account the averaging, triggering and overlap used in the plug-in. The centered speed is calculated as: CT = RPM (End _ of _ analysis ) RPM ( Begin _ of 2 _ analysis ) The RPM centering and averaging is done in the analysis plug-in prior to be connected to the waterfall. To use the centered tach simply add the said tachometer to the corresponding plug-in (FFTn or SOAn). These additional tachometers are available in the waterfall as soon as one of the result of the plug-in is added to the waterfall. 1. Add Tach to the Plug-in, 2. Add plug-in results (Spectra, orders, etc..) to the waterfall, 3. Display the waterfall, 4. Select the Plug-in Tach, as a tachometer and reference Colored floor in 3D displayss The colored 3D displays use palette that define the color of each level. With NVGate V9.10 the bottom of the Y scale remain colored with the lowest defined level. 20

21 This area remain colored even if the corresponding Oversampled waterfall collections level are above the floor of the 3D display The waterfall collects and synchronizes results generated by various calculations (plug-ins, front end, tachometers, monitor). NVGate V9.10 allows collecting the results at very different rates. This is useful while measuring at different spectral resolutions (which influence the result availability rate) or with more frequent references like tachometers. Low speed collection of spectra High speed collection of RPM RPM Spct 1 Spct 2 Spct 3 Spct 4 time Ex: Using a short periodic trigger (ex 100 ms) the waterfall collect a smooth RPM profile and the spectra at lower speed. 21

22 Miscellaneous This first bundle of the V9.00 release brings various additional evolutions such as: Windows compatibility NVGate V9.xx are compatible with the latest MS Windows versions; Windows 8 and Windows 8.1. Note that from now, on PC which have never installed NVGate, the installation directory is: C:/OROS/Programs/NVGate. It is recommend for existing installation (V8.xx or earlier) to move the software (usually in C:/Program Files/OROS/OR3X) to the new one. The teamwork analyzers (OR36/38 V3) are no more compatible with Windows XP. Spare units and physical quantities NVGate Features 4 Spare units to be used when requested physical quantity does not exist in the software. Actually these spare units are physical quantities. It is possible to rename it with NVGate V9.10. The procedure is as follow: Open the file orosunit.ini from the installation directory In the MAGNITUDE DEFINITION section goes to the Spare ones Set corresponding Ids to 0 Add a line QuantityName = new name Start NVGate and create associated units Example to create Dynamic Stifness magnitude: ; --- User free--- ; [Spare1] Id = 38 Ids = <- Set to 0 QuantityName = Dyn. Stiffness <- Add EqDim = m:0 Number = 1 Unit1 = NoUnits TypeUFF = 0 SettingUnit = 1 For using special characters (ex Asian languages) the orosunit.in file must be encoded as UTF-8. Note that the orosunit.ini file is overwritten at each new install of NVGate. Link all cursors in one click Cursors can be linked one by one to follow the same X-coordinate. It is now possible to link/un link from the cursor contextual menu. This apply to the link ad link by reference and concern all the cursors of the current layout. 22

23 Input Label reduction With the introduction of multi-analyzers operations NVGate uses the input number in the chassis (i.e. Input 12) as an identifier independently from the label itself. As the default value for the label is the same as the input identifiers the system will not display it twice when they are identical. If the lable differ, it is displayed: Input = 4, Label = Input 4 shows Input 4 Input = 4, Label = Acc top shows Input 4: Acc top This applies in the infotrace, windows head and result name. Input Label reduction With the introduction of multi-analyzers operations NVGate uses the input number in the chassis Toolkit The toolkit receive new commands and compatibility MatDrive is compatible with Matlab V14 and 64 bits Windows editions A new set of command for report Sequences of grouped commands for recurrent action See the latest version of your toolkit for details 23

24 Fixed issues Ref Designation 6984 Impossible to post-analyze low sampling tracks of a three-bandwidth signal 6884 Wrong Max bandwidth for player with signal recorded in multi bandwidth different from Front End 7001 FFT is visible in Event / Filter connection 6410 Problem for saving results in PA 7847 ERR 0x01000e Error when pasting data during Mask edition 6426 Missing slices in waterfall during post-analysis 7666 Impossible to rerecord full signal 7993 Waterfall do not detect DC input + a FFT (Post analysis) 7443 Install NVGate in program files x86 does not work on all the PCs 7429 Impossible to record DC signals in Time to stop mode 8018 Incorrect windows label with EDIT MEASUREMENT mode 8113 Waterfall trigger disappear when we load a project in connect mode 8085 Waterfall trigger switch when we save and load the project 8144 Unable to save FFT A signal weighting 8236 Incorrect data exported from Waterfall 8201 Setup Waterfall for 32 Spectrum using NVDrive is too long 24

25 OROS, Leadership through Innovation About Us Now approaching 30-years in business, OROS designs and manufacturing have been renowned for providing the best in noise and vibration analyzers as well as in specific application solutions. Our Philosophy Reliability and efficiency are our ambition everyday. We know you require the same for your measurement instruments: comprehensive solutions providing performance and assurance, designed to fit the challenges of your demanding world. Our Emphasis Continuously paying attention to your needs, OROS collaborates with a network of proven scientific affiliates to offer the latest of the technology, always based on innovation. Worldwide Presence OROS products are marketed in more than 35 countries, through our authorized network of representatives, offices and accredited maintenance centers. Want to know more? OROS headquarters OROS Inc OROS French Sales Office OROS GmbH OROS China www. w.oros.com www. w.oros.com 25

Satellite configuration for Remote / Stand-alone Noise & Vibration Analysis

Satellite configuration for Remote / Stand-alone Noise & Vibration Analysis SmartRouter TM Satellite configuration for Remote / Stand-alone Noise & Vibration Analysis DATASHEET Introduction Vibration measurements and analyses often face the reality of field operation. Far away

More information

Engineering Data Management (EDM) Software

Engineering Data Management (EDM) Software Engineering Data Management (EDM) Software Engineering Data Management (EDM) is an integrated suite of software tools from Crystal Instruments for data management and post processing. It features a single

More information

Modal. The Structural Dynamics Module. Introduction DATASHEET. Applications. Machine. Industries

Modal. The Structural Dynamics Module. Introduction DATASHEET. Applications. Machine. Industries Modal DATASHEET The Structural Dynamics Module Introduction Fig1: Geometry of a turbine shaft Modal analysis is a powerful technique for understanding structures behavior to validate simulation results,

More information

P R O D U C T D A T A

P R O D U C T D A T A P R O D U C T D A T A BK Connect FFT Analysis Applet Type 8490-A-N-SYS BK Connect applets are for customers looking for a point solution that works like they work, providing just what you need in a user-friendly

More information

OROS NVGATE 7 RELEASE NOTE

OROS NVGATE 7 RELEASE NOTE OROS NVGATE 7 RELEASE NOTE F200 953 11 1 SUMMARY Introduction... 3 New features... 3 The Vision TM Interface... 4 Overview... 4 Graphic user interface... 4 Compatibility... 5 Tabs... 6 Measuring with NVGate7...

More information

ME scope Application Note 17 Order Tracked Operational Deflection Shapes using VSI Rotate & ME scope

ME scope Application Note 17 Order Tracked Operational Deflection Shapes using VSI Rotate & ME scope ME scope Application Note 17 Order Tracked Operational Deflection Shapes using VSI Rotate & ME scope Requirements This application note requires the following software, Vold Solutions VSI Rotate Version

More information

PRODUCT DATA. BK Connect Loudness and Overall Analysis Applet Type 8490-D-N-SYS. Uses and Features

PRODUCT DATA. BK Connect Loudness and Overall Analysis Applet Type 8490-D-N-SYS. Uses and Features PRODUCT DATA BK Connect Loudness and Overall Analysis Applet Type 8490-D-N-SYS BK Connect applets are for customers looking for a point solution that works like they work, providing just what you need

More information

Using Tables, Sparklines and Conditional Formatting. Module 5. Adobe Captivate Wednesday, May 11, 2016

Using Tables, Sparklines and Conditional Formatting. Module 5. Adobe Captivate Wednesday, May 11, 2016 Slide 1 - Using Tables, Sparklines and Conditional Formatting Using Tables, Sparklines and Conditional Formatting Module 5 Page 1 of 27 Slide 2 - Lesson Objectives Lesson Objectives Explore the find and

More information

Real-time Vibration Analyzer Software

Real-time Vibration Analyzer Software Real-time Vibration Analyzer Software POWERFUL AND VERSATILE ANALYSIS TOOL The AS-410 Vibration Analyzer software merges the best features of real-time machinery analyzer, dynamic signal analyzer, transient

More information

for Q-CHECKER Text version 15-Feb-16 4:49 PM

for Q-CHECKER Text version 15-Feb-16 4:49 PM Q-MONITOR 5.4.X FOR V5 for Q-CHECKER USERS GUIDE Text version 15-Feb-16 4:49 PM Orientation Symbols used in the manual For better orientation in the manual the following symbols are used: Warning symbol

More information

LMS Pimento The Multichannel Analyzer with Portable Power

LMS Pimento The Multichannel Analyzer with Portable Power LMS Pimento The Multichannel Analyzer with Portable Power LMS INTERNATIONAL Empowering Engineering Innovation LMS Pimento The portable analyzer with professional power Looking for a solution for general

More information

Agilent MassHunter Workstation Software Report Designer Add-in

Agilent MassHunter Workstation Software Report Designer Add-in Agilent MassHunter Workstation Software Report Designer Add-in Quick Start Guide What is the Agilent MassHunter Workstation Software Report Designer Add-in? 2 Report Designer UI elements 3 Getting Started

More information

Engineering Data Management Software. User s Guide. CoCo DSA Mode Spider Real-Time Mode Post Analysis Mode (CoCo VDC Mode not included)

Engineering Data Management Software. User s Guide. CoCo DSA Mode Spider Real-Time Mode Post Analysis Mode (CoCo VDC Mode not included) EDM USER S MANUAL Engineering Data Management Software User s Guide CoCo DSA Mode Spider Real-Time Mode Post Analysis Mode (CoCo VDC Mode not included) Version 1.00 Crystal Instruments Corporation 4699

More information

m+p SO Analyzer Dynamic Signal Acquisition and Analysis

m+p SO Analyzer Dynamic Signal Acquisition and Analysis www.mpihome.com m+p SO Analyzer Dynamic Signal Acquisition and Analysis The m+p SO Analyzer acquires multichannel FFT and time data while displaying the data in real time for general FFT analysis and optional

More information

TraceFinder Analysis Quick Reference Guide

TraceFinder Analysis Quick Reference Guide TraceFinder Analysis Quick Reference Guide This quick reference guide describes the Analysis mode tasks assigned to the Technician role in the Thermo TraceFinder 3.0 analytical software. For detailed descriptions

More information

Text version 15-Aug-12. for Q-CHECKER V4, V5 and V6

Text version 15-Aug-12. for Q-CHECKER V4, V5 and V6 Text version 15-Aug-12 Q-MONITOR V4 for Q-CHECKER V4, V5 and V6 USERS GUIDE Orientation Symbols used in the manual For better orientation in the manual the following symbols are used: Warning symbol Tip

More information

KYOCERA Net Viewer User Guide

KYOCERA Net Viewer User Guide KYOCERA Net Viewer User Guide Legal Notes Unauthorized reproduction of all or part of this guide is prohibited. The information in this guide is subject to change without notice. We cannot be held liable

More information

Instruction manual. testo easyemission Software

Instruction manual. testo easyemission Software Instruction manual testo easyemission Software en 2 General Information General Information This documentation includes important information about the features and application of the product. Please read

More information

KYOCERA Net Viewer 5.3 User Guide

KYOCERA Net Viewer 5.3 User Guide KYOCERA Net Viewer. User Guide Legal Notes Unauthorized reproduction of all or part of this guide is prohibited. The information in this guide is subject to change without notice. We cannot be held liable

More information

P R O D U C T D A T A

P R O D U C T D A T A P R O D U C T D A T A BK Connect Order Analysis Applet Type 8490-B-N-SYS BK Connect applets are for customers looking for a point solution that works like they work, providing just what you need in a user-friendly

More information

TraceFinder Analysis Quick Reference Guide

TraceFinder Analysis Quick Reference Guide TraceFinder Analysis Quick Reference Guide This quick reference guide describes the Analysis mode tasks assigned to the Technician role in Thermo TraceFinder analytical software. For detailed descriptions

More information

Legal Notes. Regarding Trademarks KYOCERA MITA Corporation

Legal Notes. Regarding Trademarks KYOCERA MITA Corporation Legal Notes Unauthorized reproduction of all or part of this guide is prohibited. The information in this guide is subject to change without notice. We cannot be held liable for any problems arising from

More information

Getting Started With Estimating Extended

Getting Started With Estimating Extended Getting Started With Estimating Extended NOTICE This document and the Sage Timberline Office software may be used only in accordance with the accompanying Sage Timberline End User License Agreement. You

More information

Password Memory 7 User s Guide

Password Memory 7 User s Guide C O D E : A E R O T E C H N O L O G I E S Password Memory 7 User s Guide 2007-2018 by code:aero technologies Phone: +1 (321) 285.7447 E-mail: info@codeaero.com Table of Contents How secure is Password

More information

Intellicus Enterprise Reporting and BI Platform

Intellicus Enterprise Reporting and BI Platform Designing Adhoc Reports Intellicus Enterprise Reporting and BI Platform Intellicus Technologies info@intellicus.com www.intellicus.com Designing Adhoc Reports i Copyright 2012 Intellicus Technologies This

More information

Release notes for version 3.1

Release notes for version 3.1 Release notes for version 3.1 - Now includes support for script lines and character names. o When creating an Excel file project, it is possible to specify columns used for script lines and for character

More information

VIBBOX. 32, 48, or 64-Channel Sound & Vibration Solution Expansion to 256 Channels. Key Feature of Each VIBbox: Table 1. Key Features of VIBbox Models

VIBBOX. 32, 48, or 64-Channel Sound & Vibration Solution Expansion to 256 Channels. Key Feature of Each VIBbox: Table 1. Key Features of VIBbox Models VIBBOX 32, 48, or 64-Channel Sound & Vibration Solution Expansion to 256 Channels VIBbox is a high-accuracy, high channel count, dynamic signal analyzer system for sound and vibration applications. Each

More information

ME scope Application Note 18 Simulated Multiple Shaker Burst Random Modal Test

ME scope Application Note 18 Simulated Multiple Shaker Burst Random Modal Test ME scope Application Note 18 Simulated Multiple Shaker Burst Random Modal Test The steps in this Application Note can be duplicated using any Package that includes the VES-4600 Advanced Signal Processing

More information

AMS Suite: Machinery Health Manager 5.2 and 5.3 New Features and Enhancements

AMS Suite: Machinery Health Manager 5.2 and 5.3 New Features and Enhancements S-NSF051509 May 2009 AMS Suite: Machinery Health Manager 5.2 and 5.3 New Features and Enhancements This paper describes the new features in AMS Machinery Manager 5.2 and 5.3. The contents of this publication

More information

AKELA Vector Network Analyzer (VNA) Quick Start Guide

AKELA Vector Network Analyzer (VNA) Quick Start Guide AKELA Vector Network Analyzer (VNA) Quick Start Guide Copyright AKELA, Inc. 2012, all rights reserved http:\\akelainc.com LabVIEW and LabWindows are registered trademarks of National Instruments Incorporated

More information

DataView Release Notes Version Released

DataView Release Notes Version Released DataView Release Notes Version 3.53.0013 Released 9-25-2018 CATEGORY (v 3.53.0013): Simple Logger II Version 1.01.0059 Open button is now active when selecting recordings from the session s list. Corrected

More information

For Microsoft Windows Vista and XP Users Manual

For Microsoft Windows Vista and XP Users Manual With For Microsoft Windows Vista and XP Users Manual Microboards Technology LLC Version 1.02 2 MICROBOARDS TECHNOLOGY, LLC PrintWrite TABLE OF CONTENTS INTRODUCTION...5 WHAT IS VIDEOWRITE?...5 GX-2 DISC

More information

Thermo Xcalibur Getting Started (Quantitative Analysis)

Thermo Xcalibur Getting Started (Quantitative Analysis) Thermo Xcalibur Getting Started (Quantitative Analysis) XCALI-97207 Revision B September 2010 2010 Thermo Fisher Scientific Inc. All rights reserved. Xcalibur, Surveyor, and Accela are registered trademarks

More information

Automation functions and their licensing

Automation functions and their licensing 08/17 Automation functions and their licensing ArtemiS SUITE is a multi-functional software application supporting you efficiently and comprehensively in many areas of sound and vibration analysis. As

More information

P R O D U C T D A T A

P R O D U C T D A T A P R O D U C T D A T A BK Connect FFT, CPB and Overall Analysis Applet Type 8490-C-N-SYS BK Connect applets are for customers looking for a point solution that works like they work, providing just what

More information

Scientific Production Company Doza Configurator Software

Scientific Production Company Doza Configurator Software Scientific Production Company Doza Configurator Software Software User Manual Content 1. Purpose of the Configurator software..... 3 2. Conditions for using the software. 4 2.1 System requirements......

More information

DS-3000 Series Data Station Operation manual for Vibration Analysis

DS-3000 Series Data Station Operation manual for Vibration Analysis DS-3000 Series Data Station Operation manual for Vibration Analysis ONO SOKKI CO., LTD. This instruction manual describes basic operations of the DS-3000 Series Data Station for vibration analysis. As

More information

Product Documentation SAP Business ByDesign August Analytics

Product Documentation SAP Business ByDesign August Analytics Product Documentation PUBLIC Analytics Table Of Contents 1 Analytics.... 5 2 Business Background... 6 2.1 Overview of Analytics... 6 2.2 Overview of Reports in SAP Business ByDesign... 12 2.3 Reports

More information

Remote Manager User s Manual

Remote Manager User s Manual Manual version 1.1 Remote Manager User s Manual Hardware Installation......... 2 Introduction......... 3 Installation......... 3 System Requirements...... 4 Registration Code.... 4 Quick Start....... 4

More information

DS-0322 Tracking Analysis Software Operation manual Basic Operation procedure for Constant-ratio Tracking Analysis

DS-0322 Tracking Analysis Software Operation manual Basic Operation procedure for Constant-ratio Tracking Analysis DS-0322 Tracking Analysis Software Operation manual Basic Operation procedure for Constant-ratio Tracking Analysis ONO SOKKI CO., LTD. There are two types of tracking analysis, i.e., one is "constant ratio

More information

Sample Chapters. To learn more about this book, visit the detail page at: go.microsoft.com/fwlink/?linkid= Copyright 2010 by Curtis Frye

Sample Chapters. To learn more about this book, visit the detail page at: go.microsoft.com/fwlink/?linkid= Copyright 2010 by Curtis Frye Sample Chapters Copyright 2010 by Curtis Frye All rights reserved. To learn more about this book, visit the detail page at: go.microsoft.com/fwlink/?linkid=191751 Chapter at a Glance Analyze data dynamically

More information

Verity Central Quick Reference Manual. Document ID A04

Verity Central Quick Reference Manual. Document ID A04 Verity Central Quick Reference Manual Document ID 6620-003-A04 Welcome to Verity Central. This Quick Reference Manual is intended to be used in tandem with the Verity Central Technical Reference Manual,

More information

DataView Release Notes Version

DataView Release Notes Version DataView Release Notes Version 3.53.0011 Released 1-30-2018 CATEGORY Updates (v 3.53.0011): DataView Core Version 3.53.0011 Fixed on issue with the scroll bar on the events page of a report from a PEL

More information

TROVIS-VIEW 4 Software TROVIS Operating Instructions EB 6661 EN. Electronics from SAMSON

TROVIS-VIEW 4 Software TROVIS Operating Instructions EB 6661 EN. Electronics from SAMSON TROVIS-VIEW 4 Software TROVIS 6661 Operating Instructions Electronics from SAMSON EB 6661 EN Edition January 2015 Definition of signal words DANGER! Hazardous situations which, if not avoided, will result

More information

3.2 Circle Charts Line Charts Gantt Chart Inserting Gantt charts Adjusting the date section...

3.2 Circle Charts Line Charts Gantt Chart Inserting Gantt charts Adjusting the date section... / / / Page 0 Contents Installation, updates & troubleshooting... 1 1.1 System requirements... 2 1.2 Initial installation... 2 1.3 Installation of an update... 2 1.4 Troubleshooting... 2 empower charts...

More information

DT8824 High Stability, High Accuracy, Ethernet Instrument Module

DT8824 High Stability, High Accuracy, Ethernet Instrument Module DT8824 High Stability, High Accuracy, Ethernet Instrument Module The DT8824 Ethernet data acquisition (DAQ) module offers the highest stability and accuracy for measuring analog signals. Every signal input,

More information

PC Software R&S FS300-K1

PC Software R&S FS300-K1 Copyright 0 Copyright Copyright Licence Agreement Rohde & Schwarz grants you the right to install the R&S FS300-K1 software package on one or more PCs of your choice. The licence included in the software

More information

Online Demo Guide. Barracuda PST Enterprise. Introduction (Start of Demo) Logging into the PST Enterprise

Online Demo Guide. Barracuda PST Enterprise. Introduction (Start of Demo) Logging into the PST Enterprise Online Demo Guide Barracuda PST Enterprise This script provides an overview of the main features of PST Enterprise, covering: 1. Logging in to PST Enterprise 2. Client Configuration 3. Global Configuration

More information

ME scope Application Note 42 Multi-Input Multi-Output (MIMO) FRFs

ME scope Application Note 42 Multi-Input Multi-Output (MIMO) FRFs ME scope Application Note 42 Multi-Input Multi-Output (MIMO) FRFs NOTE: This Application Note uses commands in the VES-3600 Advanced Signal Processing Check Help About to verify authorization of these

More information

VR9500. Advantages Ease of Use. Features

VR9500. Advantages Ease of Use. Features Ease of Use system and confi gured a test within minutes of unpacking the box. Additionally, our customer support PC & Windows Integration The integrates seamlessly with your PC and Windows operating system,

More information

m+p VibControl Random Vibration Control

m+p VibControl Random Vibration Control www.mpihome.com m+p VibControl Random Vibration Control m+p VibControl is m+p international s proven software for carrying out a wide variety of vibration tests. The Random control mode is one of the most

More information

Galaxie Photodiode Array Software

Galaxie Photodiode Array Software Varian, Inc. 2700 Mitchell Drive Walnut Creek, CA 94598-1675/USA Galaxie Photodiode Array Software User s Guide Varian, Inc. 2002-2006 03-914950-00:6 Table of Contents Introduction... 3 General... 3 PDA

More information

Manual. empower charts 6.4

Manual. empower charts 6.4 Manual empower charts 6.4 Contents 1 Introduction... 1 2 Installation, updates and troubleshooting... 1 2.1 System requirements... 1 2.2 Initial installation... 1 2.3 Installation of an update... 1 2.4

More information

Vibration Analyzer, Data Collector & Dynamic Balancer

Vibration Analyzer, Data Collector & Dynamic Balancer Vibration Analyzer, Data Collector & Dynamic Balancer The most complete, reliable and productive solution for Vibration Analysis, Route Based Data Collection and Dynamic Balancing DigivibeMX is the most

More information

Vibration Analyzer Version 1.0.2

Vibration Analyzer Version 1.0.2 Vibration Research Corporation 6437 28 th Ave. Hudsonville, MI 49426 support@vibrationresearch.com Phone: (616) 669-3028 Fax: (616) 669-5337 Vibration Analyzer Version 1.0.2 File menu The File menu is

More information

Managing custom montage files Quick montages How custom montage files are applied Markers Adding markers...

Managing custom montage files Quick montages How custom montage files are applied Markers Adding markers... AnyWave Contents What is AnyWave?... 3 AnyWave home directories... 3 Opening a file in AnyWave... 4 Quick re-open a recent file... 4 Viewing the content of a file... 5 Choose what you want to view and

More information

Excel Intermediate

Excel Intermediate Excel 2013 - Intermediate (103-124) Multiple Worksheets Quick Links Manipulating Sheets Pages EX16 EX17 Copying Worksheets Page EX337 Grouping Worksheets Pages EX330 EX332 Multi-Sheet Cell References Page

More information

Xcor MHV Client User Guide

Xcor MHV Client User Guide Xcor MHV Client User Guide MHV CUG v.1.0.2 July 2010 This document details the functionality of the MHV Client software program. It is intended to be a Quick Start guide for using the system, and provides

More information

Using the Spectrum Management Tools

Using the Spectrum Management Tools CHAPTER 4 Revised: June 28, 2007, Using the Trace Window CBT 3.3 interfaces with the Cisco CMTS to provide return path spectrum analysis, which is provided in the following tasks: Trace Window To monitor

More information

Microsoft Excel 2007 Creating a XY Scatter Chart

Microsoft Excel 2007 Creating a XY Scatter Chart Microsoft Excel 2007 Creating a XY Scatter Chart Introduction This document will walk you through the process of creating a XY Scatter Chart using Microsoft Excel 2007 and using the available Excel features

More information

Chapter at a glance. Analyze. Filter. Format. Create. Analyze data dynamically by using PivotTables, page 288

Chapter at a glance. Analyze. Filter. Format. Create. Analyze data dynamically by using PivotTables, page 288 Chapter at a glance Analyze Analyze data dynamically by using PivotTables, page 288 Filter Filter, show, and hide PivotTable data, page 298 Format Format PivotTables, page 313 Create Create dynamic charts

More information

Salt Traxx Operation Operation without a Flash Drive Operation with a Flash Drive

Salt Traxx Operation Operation without a Flash Drive Operation with a Flash Drive Salt Traxx Operation Turn unit on if it is not already on. If the unit has not been calibrated it will display CALIBRATE ME (See Setup). The Start/Stop button is functional and spreading may be performed

More information

ARES. User s Guide. Aprilia Racing Engine Setup. English version

ARES. User s Guide. Aprilia Racing Engine Setup. English version ARES Aprilia Racing Engine Setup User s Guide English version ARES user s guide 2/59 I. WARNINGS... 6 II. SOFTWARE AND ENGINE CONFIGURATION COMPATIBILITY... 6 III. BEFORE UPDATING ARES TO A NEWER VERSION...

More information

ScannerCal Accuracy Verification System for the FlowScanner

ScannerCal Accuracy Verification System for the FlowScanner ScannerCal Product Bulletin ScannerCal Accuracy Verification System for the FlowScanner www.fisher.com Product Bulletin ScannerCal ScannerCal Accuracy Verification System Verify the calibration and accuracy

More information

Spreadsheet definition: Starting a New Excel Worksheet: Navigating Through an Excel Worksheet

Spreadsheet definition: Starting a New Excel Worksheet: Navigating Through an Excel Worksheet Copyright 1 99 Spreadsheet definition: A spreadsheet stores and manipulates data that lends itself to being stored in a table type format (e.g. Accounts, Science Experiments, Mathematical Trends, Statistics,

More information

Agilent ChemStation Plus

Agilent ChemStation Plus Agilent ChemStation Plus Getting Started Guide Agilent Technologies Notices Agilent Technologies, Inc. 2004, 2006-2008 No part of this manual may be reproduced in any form or by any means (including electronic

More information

Rat 2D EPSI Dual Band Variable Flip Angle 13 C Dynamic Spectroscopy

Rat 2D EPSI Dual Band Variable Flip Angle 13 C Dynamic Spectroscopy Rat 2D EPSI Dual Band Variable Flip Angle 13 C Dynamic Spectroscopy In this example you will load a dynamic MRS animal data set acquired on a GE 3T scanner. This data was acquired with an EPSI sequence

More information

Spectramag-6 Six-Channel Spectrum Analyser for Magnetic Field and Vibration Surveys. For innovation in magnetic measuring instruments

Spectramag-6 Six-Channel Spectrum Analyser for Magnetic Field and Vibration Surveys. For innovation in magnetic measuring instruments Spectramag-6 Six-Channel Spectrum Analyser for Magnetic Field and Vibration Surveys For innovation in magnetic measuring instruments Spectramag-6 Six-Channel Spectrum Analyser for Magnetic Field and Vibration

More information

Instruction Manual XLComm Data Acquisition Software For XL Series Meters

Instruction Manual XLComm Data Acquisition Software For XL Series Meters Data Acquisition Software For XL Series Meters (XL 15, 20, 25, 30, 40, 50 and 60 meters) 68X090832 Rev. 0 JAN 07 Preface This manual serves to explain the use of the Acquisition Software. The manual functions

More information

VIBbox 64-Channel Sound & Vibration Solution

VIBbox 64-Channel Sound & Vibration Solution VIBbox 64-Channel Sound & Vibration Solution VIBbox is a high-accuracy, high channel count, dynamic signal analyzer system for sound and vibration applications. VIBbox packages four DT9857E modules in

More information

Information Technology and Media Services. Office Excel. Charts

Information Technology and Media Services. Office Excel. Charts Information Technology and Media Services Office 2010 Excel Charts August 2014 Information Technology and Media Services CONTENTS INTRODUCTION... 1 CHART TYPES... 3 CHOOSING A CHART... 4 CREATING A COLUMN

More information

Customer ( you ) must review these notes prior to installing or operating the Attune NxT Software version ( Attune Software v1.1.0 ).

Customer ( you ) must review these notes prior to installing or operating the Attune NxT Software version ( Attune Software v1.1.0 ). Life Technologies Attune NxT Software version 1.1.0 Release Notes Customer ( you ) must review these notes prior to installing or operating the Attune NxT Software version 1.1.0 ( Attune Software v1.1.0

More information

CoCo-80 Quick Reference

CoCo-80 Quick Reference CoCo-80 Quick Reference Vibration Data Collector Mode 7/24/2012 Crystal Instruments Corporation 2370 Owen Street Santa Clara, CA 95054, USA www.go-ci.com +1 (408)986-8880 Document History Crystal Instruments

More information

WLAN MIERUZZO BASIC SOFTWARE

WLAN MIERUZZO BASIC SOFTWARE DK-5000 Series WLAN MIERUZZO BASIC SOFTWARE USER S MANUAL DK-5005A, DK-5010A, DK-5030A DK-5005B, DK-5010B, DK-5030B DK-5005C, DK-5010C, DK-5030C DK-5005D, DK-5010D, DK-5030D This manual was last revised

More information

IRIS POWER TURBO. Machine Condition Monitoring System for Turbo Generators

IRIS POWER TURBO. Machine Condition Monitoring System for Turbo Generators IRIS POWER TURBO Machine Condition Monitoring System for Turbo Generators PREDICTIVE MAINTENANCE On-line monitoring system installed in power production plants ensures continuous monitoring of exploitation

More information

-Table of Contents- 1. Overview Installation and removal Operation Main menu Trend graph... 13

-Table of Contents- 1. Overview Installation and removal Operation Main menu Trend graph... 13 Thank you for buying Data Analysis Software. In order to use this software correctly and safely and to prevent trouble, please read this manual carefully. Notice 1. No part of this manual can be reproduced

More information

NanoWin. User's Manual - Rel. NW-1.1. Windows 9x and Windows NT 4.0 Data Management Software for NANOVIP Plus and NANOVIP Plus MEM Handheld Analysers

NanoWin. User's Manual - Rel. NW-1.1. Windows 9x and Windows NT 4.0 Data Management Software for NANOVIP Plus and NANOVIP Plus MEM Handheld Analysers NanoWin User's Manual - Windows 9x and Windows NT 4.0 Data Management Software for NANOVIP Plus and NANOVIP Plus MEM Handheld Analysers Page 1 of 35 NanoWin Windows 9x and Windows NT 4.0 Data Management

More information

SAP BusinessObjects Live Office User Guide SAP BusinessObjects Business Intelligence platform 4.1 Support Package 2

SAP BusinessObjects Live Office User Guide SAP BusinessObjects Business Intelligence platform 4.1 Support Package 2 SAP BusinessObjects Live Office User Guide SAP BusinessObjects Business Intelligence platform 4.1 Support Package 2 Copyright 2013 SAP AG or an SAP affiliate company. All rights reserved. No part of this

More information

QUADRA-CHEK 2000 Demo User's Manual. Evaluation Unit

QUADRA-CHEK 2000 Demo User's Manual. Evaluation Unit QUADRA-CHEK 2000 Demo User's Manual Evaluation Unit English (en) 06/2018 Contents Contents 1 Fundamentals...7 2 Software Installation...11 3 Basic Operation... 17 4 Software Configuration...41 5 Quick

More information

MIZ-21C Software Product Bulletin

MIZ-21C Software Product Bulletin Table of Content Table of Content... 2 Purpose of MIZ-21C Software 1.0.6... 3 Downloading and Installing MIZ-21C Software 1.0.6... 3 New Features in MIZ-21C Software 1.0.6... 4 Software Update Reliability...

More information

MAS 90/200 Intelligence Tips and Tricks Booklet Vol. 1

MAS 90/200 Intelligence Tips and Tricks Booklet Vol. 1 MAS 90/200 Intelligence Tips and Tricks Booklet Vol. 1 1 Contents Accessing the Sage MAS Intelligence Reports... 3 Copying, Pasting and Renaming Reports... 4 To create a new report from an existing report...

More information

1510A. MTI Instruments, Inc. 325 Washington Avenue Extension, Albany, New York USA Phone: (518) FAX: (518)

1510A. MTI Instruments, Inc. 325 Washington Avenue Extension, Albany, New York USA Phone: (518) FAX: (518) Revision 3.1 August 7, 2014 1510A Precision Signal Source Note: Performing a user calibration with the software package will result in an accuracy of 2% at best. A factory cal is required to achieve the

More information

REMOTE MANAGER (YellowFin d Fixed WiMAX Analzyer) Manual version 1.0

REMOTE MANAGER (YellowFin d Fixed WiMAX Analzyer) Manual version 1.0 REMOTE MANAGER (YellowFin 802.16d Fixed WiMAX Analzyer) Manual version 1.0 Remote Manager User s Manual Introduction......... 2 Installation......... 2 System Requirements........ 3 Registration Code......

More information

IntesisBox MAPS. Configuration & monitoring software of IntesisBox KNX series. User's manual Issue Date: 06/17 r1.0 eng

IntesisBox MAPS. Configuration & monitoring software of IntesisBox KNX series. User's manual Issue Date: 06/17 r1.0 eng IntesisBox MAPS Configuration & monitoring software of IntesisBox KNX series User's manual Issue Date: 06/17 r1.0 eng Intesis Software S.L.U. 2017 All Rights Reserved. Information in this document is subject

More information

Using OPUS to Process Evolved Gas Data (8/12/15 edits highlighted)

Using OPUS to Process Evolved Gas Data (8/12/15 edits highlighted) Using OPUS to Process Evolved Gas Data (8/12/15 edits highlighted) Once FTIR data has been acquired for the gases evolved during your DSC/TGA run, you will process using the OPUS software package. Select

More information

NEST i.4.0 v1.1 datasheet

NEST i.4.0 v1.1 datasheet TDS3224 April 2018 B NEST i.4.0 v1.1 datasheet MONITORING AND DIAGNOSIS OF ROTATING MACHINES Predictive maintenance is a powerful leverage of competitiveness for all industrialists. As its benefits are

More information

NON-SELLABLE PRODUCT DATA

NON-SELLABLE PRODUCT DATA PRODUCT DATA NON-SELLABLE Acoustic Test Consultant with Noise Source Identification Type 7761 with Robot Option BZ-5370 and PULSE Position Detection Option for Acoustic Test Consultant BZ-5611 Acoustic

More information

testo easyheat Configuration and Analysis software Instruction manual

testo easyheat Configuration and Analysis software Instruction manual testo easyheat Configuration and Analysis software Instruction manual en 2 General Information General Information This documentation includes important information about the features and application of

More information

LxT Version October LxT Version December LxT Version January 2014

LxT Version October LxT Version December LxT Version January 2014 SoundTrack LXT & SoundExpert LxT Release History Enhancements and Fixes for SoundTrack LxT and SoundExpert LxT Firmware 1 LxT Version 2302 October 2017 Corrected calculation for Under-Range Value was lower

More information

Manual. User Reference Guide. Analysis Application (EMG) Electromyography Analysis

Manual. User Reference Guide. Analysis Application (EMG) Electromyography Analysis Phone: (888) 765-9735 WWW.MINDWARETECH.COM User Reference Guide Manual Analysis Application Electromyography Analysis (EMG) Copyright 2014 by MindWare Technologies LTD. All Rights Reserved. 1 Phone: (614)

More information

Report Generator for DPOPWR

Report Generator for DPOPWR Online Help Report Generator for DPOPWR Adapted from the Report Generator for DPOPWR Online Help www.tektronix.com Copyright Tektroni x. All rights reserved. Licensed software products are owned by Tektronix

More information

WiFi Advisor Wireless LAN Analyzer Quick Start Guide. October 2015 Revision OCT-2015 Technical Assistance: GO VIAVI /

WiFi Advisor Wireless LAN Analyzer Quick Start Guide. October 2015 Revision OCT-2015 Technical Assistance: GO VIAVI / WiFi Advisor Wireless LAN Analyzer Quick Start Guide October 2015 OCT-2015 Technical Assistance: 1.844.GO VIAVI / 1.844.468.4284 1 Contents 1. WiFi Advisor Wireless LAN Analyzer Overview... 4 2. The WFED-300AC

More information

SaxoTraderPRO Intro guide

SaxoTraderPRO Intro guide SaxoTraderPRO Intro guide Table of Content SETTING UP THE WORKSPACE... page 3 SAVING AND MANAGING WORKSPACES (latest edition).............. page 7 WATCHLIST MANAGEMENT... page 8 OPENING ONE OR MANY CHART

More information

16-Bit A/D Converter (ENOB=14.1) 16-bit D/A. 16-bit D/A. Digital I/O (8/8) Counter/Timer (2)

16-Bit A/D Converter (ENOB=14.1) 16-bit D/A. 16-bit D/A. Digital I/O (8/8) Counter/Timer (2) DT9818 Isolated, Embedded USB Data Acquisition Board The DT9818 is perfect for embedding in a custom application where isolation is required. The DT9818 is a highperformance USB data acquisition (DAQ)

More information

1. Concepts and What s New Concepts What's New in E Getting Started Starting Electra Page Scale

1. Concepts and What s New Concepts What's New in E Getting Started Starting Electra Page Scale 1 1. Concepts and What s New... 6 1.1 Concepts... 6 1.2 What's New in E6... 7 2. Getting Started... 8 2.1 Starting Electra... 8 2.2 Page Scale... 8 2.3 Page Measurement Units... 9 2.4 Stencils and Drawing

More information

ADD A 3-D PIE CHART TO THE WORKBOOK

ADD A 3-D PIE CHART TO THE WORKBOOK ADD A 3-D PIE CHART TO THE WORKBOOK A pie chart is an easy way to show the relationship of items to the whole. In this exercise, you will be creating a Pie Chart that will show the relationship between

More information

SIVIC GUI Overview. SIVIC GUI Layout Overview

SIVIC GUI Overview. SIVIC GUI Layout Overview SIVIC GUI Overview SIVIC GUI Layout Overview At the top of the SIVIC GUI is a row of buttons called the Toolbar. It is a quick interface for loading datasets, controlling how the mouse manipulates the

More information

D A X A D D - I N AMPLICON DATA ACQUISITION EXCEL ADD-IN

D A X A D D - I N AMPLICON DATA ACQUISITION EXCEL ADD-IN D A X A D D - I N AMPLICON DATA ACQUISITION EXCEL ADD-IN This Instruction Manual is supplied with the Data Acquisition Add-in to provide the user with sufficient information to utilise the purchased product

More information

Operating instructions - Cary 100 Bio UV-visible Spectrophotometer

Operating instructions - Cary 100 Bio UV-visible Spectrophotometer Operating instructions - Cary 100 Bio UV-visible Spectrophotometer This document describes how to power up the spectrophotometer, set its measurement parameters, insert one or more of samples for analysis

More information

Noise Explorer is a program for storing, retrieving and converting measurement data from Brüel & Kjær sound level and noise dose meters.

Noise Explorer is a program for storing, retrieving and converting measurement data from Brüel & Kjær sound level and noise dose meters. Tutorial Overview of Noise Explorer Noise Explorer is a program for storing, retrieving and converting measurement data from Brüel & Kjær sound level and noise dose meters. Noise Explorer uses a unique

More information