RM5 HD configuration software Operating Manual
|
|
- Jodie Floyd
- 5 years ago
- Views:
Transcription
1 Multiconfig RM5 HD configuration software EN Operating Manual Cod. DMOGE0001.0EN Rev
2 GUIDE TO THE SYMBOLS IN THIS MANUAL The following symbols have been included in this manual to facilitate its consultation. Important information Read carefully before use Caution!
3 Contents Contents Introduction Product description Warnings Download and Installation of Multiconfig Software Download Installation Multiconfig Software Connection to a PC Starting the Multiconfig Software Status Tab Test Tab Coins Tab Sorting Tab Tuning Tab Channels Tab Clone File Save File Firmware Update Appendix Test Box EN 1. Introduction This instructions and its annexes provide all the necessary information for a correct configuration of the product and all its components, as well as for its correct use and maintenance. The information contained in this manual can be modified without prior notice and do not constitute a commitment on behalf of Comesterogroup. The latest version of this manual is always available online ( The information contained in this manual has been collected and verified with the utmost care; however Comesterogroup has no liability arising from its use. Unless otherwise stated, any reference to companies, names, dates, and addresses is purely coincidental and has the sole purpose to illustrate the use of the product. The reproduction of any part of this manual without prior authorisation by Comesterogroup is prohibited. 3
4 Operating Manual Multiconfig for RM5 HD 2. Product description MultiConfig software is a software package developed by Comesterogroup to allow a complete configuration of the RM5 HD s settings and all the parameters and operation modes. Configurating the RM5 HD coin mechanism means setting the operation mode most suited to the user s requirements. Configuration allows, for example, carrying out operations such as self-learning or some operating parameters. 3. Warnings Read this manual carefully before use. The indications and information contained in this manual are essential for a correct use of the product. Pay attention to the electrical connections. Faults and malfunctions deriving from non-compliance with the instructions contained in this manual are not covered by guarantee. In this document, symbols are used to highlight important aspects that must be carefully observed. 4. Download and Installation of Multiconfig Software 4.1 Download 1. If you don t have the Multiconfig software at your disposal, you can easily download it from the RM5 HD s support page on Comesterogroup website. 4 Figure 1
5 2. Clicking the link the RM5 HD s support page will be displayed. Here you can download any tools or software you need. To download any Software or Firmware driver you must log in as registered user, if you have not already registered this is a very quick process. Just click on Subscribe and follow the on-screen instructions. Click on Login to insert your login details, or click on Subscribe to create a new account EN Figure 2 3. After logging in, the screen will change slightly. Your name will be displayed in the top left hand corner of the screen near the flag of your language. 4. Click on Support tab (Figure 3) Then click on Multiconfig in the Software, Firmware Drivers and Setting area (Figure 4). Click on Support Figure 3 5
6 Operating Manual Multiconfig for RM5 HD Figure 4 5. After clicking this link, a file download dialog box will appear. Click on Save to save the file. Figure 5 6. You can save the file anywhere that is convenient, as long as you can remember where it is when you want to install the software. 6
7 Press drop down menu to choose location Click on Save Figure 6 7. After choosing a location where to save the file, a file transfer dialog box will appear showing the progress of the file download : EN Figure 7 If you have no internet access, you can ask for support calling the Comestero Group Call Center at the following telephone number : /
8 Operating Manual Multiconfig for RM5 HD 4.2 Installation 1. Installing the Multiconfig software is very easy. Find the Multiconfig zipped file you downloaded earlier, extract the installation file from the zipped file and double click the extracted file (named setup.exe) this will start the installation process. 2. Click on Next button. Figure 8 8 Figure 9 3. Select RM5 HD option and click on Next button.
9 EN Figure Select the Language you need and then click on Next button. Figure You can choose where you would like to install the software, or just accept the default location (as shown here below ). Then click on Next button. 9
10 Operating Manual Multiconfig for RM5 HD Figure Select I Agree and then click on Next button. Figure Select Next button to confirm the installation. 10
11 EN Figure 14 Figure Once the installation is complete, you will have a new program group called Multiconfig 2 in the Windows Start Menu, similar to the one shown below. 11
12 Operating Manual Multiconfig for RM5 HD Figure 16 5 Multiconfig Software Before starting up Multiconfig software, connect the RM5 HD to your PC by means of the cctalk connector. 5.1 Connection to a PC RM5 HD can be connected to a PC by means of a cctalk connector (see table below in order to choose the correct cable you need). This connection allows to configure RM5 HD in all its functions by means of the Multiconfig program. 1. Connect the cctalk cable to the coin validator CCTALK port. 12
13 CCTALK port cctalk Cable Code Cable Length (in cm) AGCAVOCCPC80 80 AGCAVOCCPC AGCAVOCCPC/C Power supply unit +12Vdc 500 ma Figure 17 The cctalk cable is provided with serial connector. If you haven t any serial port on your PC, use a common serial to USB adapter. (Cod. CAVOUSB/SERIALE). The cctalk cable is splitted in two. To connect the RM5 HD to power, you need an external power supply unit 12Vdc - 500mA. EN 5.2 Starting the Multiconfig Software 1. You can run the Multiconfig software by clicking the Multiconfig 2 menu entry or the icon Multiconfig 2 on your desktop. Figure 18 13
14 Operating Manual Multiconfig for RM5 HD 1. The initial program screen looks like this: Figure Make sure that the RM5 HD is powered up and the cctalk cable is connected before going any further. All of the program options can be accessed from the menu bar at the top of the screen. The function of each icon underneath the menu bar, is indicated by a tooltip indicator. 3. If you need to change language, select Tools -> Language. Now you can choose your language. Click on Tools -> select Language -> choose the desired language Figure Once the language has been selected, a message asking to close and restart software, will be displayed: Figure Once Multiconfig software has been restarted the chosen language is active. Now you can start the configuration session clicking on File, then New or the toolbar icon. 14
15 Figure 22 Click icon New on the toolbar icon EN Figure Then Connect New Device pop up will be displayed. Figure If you are a beginner click on OK button and let the program auto detect the device. Then go to step If you are an expert user, follow the instruction below (Figure 25 and Figure 26). 15
16 Operating Manual Multiconfig for RM5 HD - From Select Device press on dropdown menu and select RM5-HD Professional. Figure 25 - From Select Connection press on drop-down menu and select your connection number. - Press OK to start the Multiconfig device data reading. Figure 26 16
17 9. The software, after few seconds, recognizes the device and then detects its configuration. The following screen will be displayed: EN Figure The configuration screen shows the following six tabs : - Status : allows to view the status of your coin validator and set some important configuration parameters. - Test : allows you to perform a series of tests to verify the correct operation of the coin mechanism. - Coins : contains information about coins which the coin validator is enabled to identify. - Sorting : allows to set sorter parameters. - Tuning : allows to make Self Prog, Calibration, Verify and to recognize coins and tokens different from those set by default. - Channels : allows to see for each channel, the minimum and maximum acceptable values for each parameter. Figure 28 In the lower part you can find five buttons: Clone, Read, Reset, Write, Cancel. 17
18 Operating Manual Multiconfig for RM5 HD Figure 29 Some of these buttons will be shown in detail later in this manual. 5.3 Status Tab Press the Write button to write any changes directly onboard the coin validator. In the event you don t press the Write button your changes will not be set onboard the coin validator. The Status tab will be displayed as follows: Figure 30 18
19 Other options you can select Coins On String Option Mode EN Figure 31 The options you can set from now on depend on the operating mode. The first selection regards the operating mode of the coin validator. In the Options Mode area you can select : cctalk: the coin validator works with cctalk protocol. Validator: the coin validator works in validator mode. Totalizer: the coin validator works in totalizer mode. This selection can be made only using the configuration via MultiConfig software. In Options area you can also find a list of options you may select. You can t change the other 10 options, because these are factory setting. Low Inhibit: this selection regards only the options Validator. It allows the coin validator to be inhibited with a low voltage signal (typically 0 Volt or GND). Hole coins : enables the identification of coins with hole. Accept multiple channel: allows the coin validator to accept two (or more) different sets of parameter values for the same coin (see Channels Tab paragraph). Manage fakes: the coin validator can learn to recognize a fake coin. C.O.S./Fraud alarms : if the coin validator works with cctalk protocol, this option allows you to receive a code alarm message in the event a wire is detected from the coin validator. You can set the time interval in Alarm(s) interval box on the right of the screen. 19
20 Operating Manual Multiconfig for RM5 HD Fraud Block : the coin validator can be locked for a time in case the sensors detect coin return. Spain pin mapping : pin-out change (only if coin validator is set as a Validator ). The second selection regards the Coin On String area. Here you can select : Inhibit time (s) : you can set the time interval (in seconds) when coin validator remains locked. Alarm Interval (s) : you can set the time interval (in seconds) when coin validator send an alarm message (3 seconds is the default time interval). 5.4 Test Tab The Test tab will be displayed as follows: Figure 32 Idle values Events and counter Test mode Outputs Time interval Test Solenoids and Opto states Self Check Figure 33 This tab allows to perform a series of tests to verify the correct operation of the coin mechanism. 20
21 Idle Values : allows to compare the sensor values of the coin validator with the reference values in a state of rest. Test Outputs : selecting one of the options on Test Outputs Mode you can choose to send a pulse ( Pulse ) or a status signal ( Latch ) from one or both outputs of the coin validator to verify that it works correct. In order to use this function, you have to connect to RM5 HD the Test box (Cod. RM/TESTER/SA). See on Chapter 9 to find further details. Test Solenoids: clicking on Test Solenoids you can make a check of the solenoid of the Coin acceptance channels. Opto states: clicking on Read Optos you can perform the signal s test sent from each of the two optical sensors, placed along the path of the coin validator. In this way you can check the possible presence of coins stuck in correspondence of their position. If you have coins stuck in one of the two positions, the colour of the related circle changes from green to red. Checksum: not used for RM5 HD. Self Check: clicking on Test you can perform a check of the operations. If the test goes successfully the colour of the circle is green and the OK message is displayed. Events and Counters: clicking on Update buttons you can load the information about last five occurred events and the accounting of the loaded coins (Inserted, Accepted, Rejected, Fakes). In this way you can know the causes of the possible faults and also request an automatic update of events and accounting for a set time interval. 5.5 Coins Tab The Coins tab will be displayed as follows: EN Figure 34 21
22 Operating Manual Multiconfig for RM5 HD Set the amount for each row only if you have chosen in Status Tab Totalizer as option mode Save Coins IDs and Load Coins IDs Coin ID Figure 35 This tab contains information about coins which the coin validator is enabled to identify. To enable or disable one denomination you can tick off or not the check mark in the appropriate box. Value Column : allows to set the amount of each coin. Fill the values in this column only If you have chosen Totalizer as Option mode in Status tab. if you have chosen cctalk or Validator option in Status tab, don t complete this column. Coin ID : allows to set the coin ID for each coin. For example EU050A means : EU = EURO 050 = COIN CURRENCY A = COIN EDITION Press this button to save in a.txt file the complete dataset Press this button to load the.txt file of the dataset to import. In the event you have already a dataset file and you want to load it onboard the RM5 HD proceed as follow. 22
23 1- Click Load Coins IDs button. EN Figure Select the file to load onboard the Coin Validator and click on Open. OPEN Figure 37 23
24 Operating Manual Multiconfig for RM5 HD 3- Click on Write button. 5.6 Sorting Tab Figure 38 The Sorting tab will be displayed as follows: 24 Figure 39 This tab contains information to set the coins sorter.
25 Before proceeding to set the sorter, select in the Status tab which kind of sorter you want to use: Select in the drop down menu which kind of sorter you want to use Figure 40 EN - In the event you have set cctalk as your Option mode, you don t have to do anything in the sorter tab, because the sorter choice is made by the machine that pilots the coin validator. - In the event you have set Validator or Totalizer as your Option mode, in column Sort 1 you have to set the output sorter number you want to use for each coin. Input the output sorter number channel you want to use for each coin. Figure 41 25
26 Operating Manual Multiconfig for RM5 HD Sorting Tab Coins Tab Figure 42 Figure 43 The Coin column numbers shown in the Sorting tab and the Coin column numbers shown in the Coins tab are the same. 5.7 Tuning Tab The Tuning tab allows to make Self Prog, Calibration, Verify and to recognize coins and tokens different from those set by default. Self Prog is the quick and simple procedure with which the coin validator, by the insertion of 15 samples, learns parameters to recognize a new token or a new coin different from those set by default. Self Prog. Select the channel you want to use and press Start Figure 44 Calibration is a complex procedure to identify parameters for coins or tokens and requires the insertion of a much greater number of samples, typically or more. 26
27 Calibration Select the channel and press Start To start the calibration proceed as follows: Figure In Options set the channel where to program the token or coins and press Start. 2. Insert coins or tokens. Please insert the coins or the tokens three times placing the coin validator in the following ways: normal position (perpendicular), inclined forward and inclined back. At the end push Stop button. EN Figure The following window is displayed. Push OK to confirm. 27
28 Operating Manual Multiconfig for RM5 HD Figure Click on Write to transfer the changes to the coin validator. Figure 48 Verify is the procedure to check if the calibration has been done. Select Verify to check the calibration Press Start to start the calibration check Figure 49 28
29 5.8 Channels Tab The Channels tab will be displayed as follows: EN Figure 50 This tab contains a table in which rows represent channels and columns represents measurement parameters. The boxes show for each channel the minimum and maximum acceptable values for each parameter. In the white column Coin you can find reference codes of coins as stated in the Coins Tab. In the green column En. you can enable the reading of the coin by means of a check mark. In the red column Fake, you can set the calibration channel as fake coin through a tick mark, in order to handle the recognition of fakes. In the lower part you can find the following buttons : Figure 51 Clicking on Reset Channel button, you can reset the single channel. Clicking on Reset All button, you can reset all the channels. At the end of this operation the coin validator will be blank. 29
30 Operating Manual Multiconfig for RM5 HD Clicking Check Overload button, you can ask to the coin validator to check if there are similar parameter values for different coins or tokens. In this case, when two channels have an Overlapping, a message of warning is sent. Copy Channel: allows to copy the values from a single channel to another one. At the end of the operations, by means of Save Channels button, you can save the changes in a file. Furthermore you can also import data from a saved file, using Load Channels button. Press this button to load a.csv file containing only the numbers of channels and measurement parameters. 6. Clone File To save all the coin validator s configuration and tuning you made on multiconfig software, proceed as follows (this operation save all Multiconfig s tabs): 1- In the Status tab click on Clone button Clone button Figure The following window will be displayed. Click the A button. Figure Select the file you want to export into the RM5 HD. Then click on Open button. 30
31 OPEN Figure The following screen will be displayed. Click on Clone From File button to export. EN Figure When the export is ended, the following window will be displayed. Click on Back button. Figure 56 31
32 Operating Manual Multiconfig for RM5 HD 7. Save File To save a file, proceed as follows : 1- In the Status tab, click on Clone button. Clone button Figure The following screen will be displayed. Click on the A button. Figure 58 32
33 3- Choose where to save the file and name it. Then click on Open button. Press drop down menu to choose location OPEN Figure The following screen will be displayed. Click on Clone to File button to save the file. EN Figure Click on OK button. Now the file is saved. Figure 61 33
34 Operating Manual Multiconfig for RM5 HD 8. Firmware Update This procedure explains how to update the RM5HD firmware. 1- Go in the Multiconfig initial screen. 2- Select Tools and then Firmware Update. Click on Tools -> select Firmware Update Figure The warning message Your device could be damaged permanently. Disconnect any device BEFORE proceeding with the update will be displayed. Figure Press on YES button. 5- Then Connect New Device popup will be displayed. See chapter 5 for details. 6- Find the location where you saved the firmware file. Then select the new firmware file and click on Open button. Figure 64 34
35 7- Turn OFF and turn ON the RM5 HD disconnecting and connecting the cctalk cable. Then press OK. Figure The firmware Updating will start immediately. EN Figure At the end of this procedure the following message will be displayed: Figure Press on OK button. Now your firmware is updated 9. Appendix 9.1 Test Box This procedure explains how to use a Test box (Cod. RM/TESTER/SA) to test the RM5 HD s channels. 1- If you haven t already connected the coin validator to a Pc, see paragraph 5.1 to know how to do. Otherwise go on with the procedure. 2- Connect the Test Box to coin validator s SEP port with the flat cable provided and the cctalk cable to CCTALK port. 35
36 Operating Manual Multiconfig for RM5 HD SEP port cctalk cable Flat cable Figure Select Test tab in Multiconfig software and then select which channel you want to check. Select the channel(s) you want to check Figure 69 36
37 4- Click on Test Output Lines button. Click on Test Output Lines button Figure 70 EN 5- Then look at your Test box. The Leds relative to the channels you have just selected, will be all Reds. Figure If all Leds are switch on, all channels selected work correctly. Otherwise, if one or more leds ( as shown in Figure 73) are switched off, the select channel doesn t work correctly 7- In the following example (see Figures 72 and Figure 73), we have simulated that channel number 3 (CH3)doesn t work correctly. 37
38 Operating Manual Multiconfig for RM5 HD Figure 72 Figure 73 38
39 39 EN
40 Comesterogroup Italia S.r.l. Via Marie Curie 8, Gessate (MI) Tel : Fax: comestero@comesterogroup.it 40
SECTION 3 NV9 USB MANUAL SET
SECTION 3 NV9 USB MANUAL SET ITL SOFTWARE SUPPORT GUIDE NV9 USB Manual Set Section 3 2 NV9 USB MANUAL SET SECTION 3 3. ITL SOFTWARE SUPPORT GUIDE 3 3.1 Validator Manager Software 3 3.1.1 Preparing for
More informationSR5 Serial Protocol - Issue 1.6
cctalk bus SR5 Serial Protocol - Issue 1.6 This document is the copyright of Money Controls Ltd and may not be reproduced in part or in total by any means, electronic or otherwise, without the written
More informationSMART Coin System QUICK START AND CONFIGURATION GUIDE
SMART Coin System QUICK START AND CONFIGURATION GUIDE SMART Coin System Quick Start and Configuration Guide 2 SMART Coin System Quick Start and Configuration Guide 1 INTRODUCTION 4 2 ASSEMBLY 5 2.1 Detaching
More informationSR5 MechTool TM Manual TSP012.doc Issue 2.1 June 2004
This document is the copyright of Money Controls Ltd and may not be reproduced in part or in total by any means, electronic or otherwise, without the written permission of Money Controls Ltd. Money Controls
More informationElectronic Coin Validator. Operating Manual. Cod. DMGEH EN Rel
RM5 HD Electronic Coin Validator EN Operating Manual Cod. DMGEH00001.3.2EN Rel. 1.3.2 27 10 2015 GUIDE TO THE SYMBOLS IN THIS MANUAL The following symbols have been included in this manual to facilitate
More informationccprogrammer User Manual TSP041.doc Issue 3.3 June 2004
This document is the copyright of Money Controls Ltd and may not be reproduced in part or in total by any means, electronic or otherwise, without the written permission of Money Controls Ltd. Money Controls
More informationQUICK START USER GUIDE. Data Logger Model L452
QUICK START USER GUIDE Data Logger Model L452 Statement of Compliance Chauvin Arnoux, Inc. d.b.a. AEMC Instruments certifies that this instrument has been calibrated using standards and instruments traceable
More informationEU Driver s Hours Rules covered by Digifobpro. Table of contents
EU Driver s Hours Rules covered by Digifobpro Digifobpro provides analysis of Driver Cards both in it s Quick View and Driver Card - Download features ( see Digifobpro Functions page 4). There follows
More informationCLIQ Web Manager. User Manual. The global leader in door opening solutions V 6.1
CLIQ Web Manager User Manual V 6.1 The global leader in door opening solutions Program version: 6.1 Document number: ST-003478 Date published: 2016-03-31 Language: en-gb Table of contents 1 Overview...9
More informationPhoneLink for Outlook User Manual
PhoneLink for Outlook User Manual for use with 8810, 8610/8620, and 6210/6220 ISDN Telephones PhoneLink for Outlook is an add-in for Microsoft Outlook that manages inbound calls to multiple call appearances
More informationRace Studio 2. Race Studio 2 Configuration User s manual. Race Studio Configuration: user s manual 1
Race Studio 2 Race Studio 2 Configuration User s manual Race Studio Configuration: user s manual 1 AIM s.r.l. reserves the right to make changes in the content of this manual without obligation to notify
More information2214 EVENT LOGGER MODULE FOR THE VX2200 SYSTEM
2214 EVENT LOGGER MODULE FOR THE VX2200 SYSTEM CONTENTS PAGE Manual Introduction 3 Product Overview 3 Operation and Connection 3 RS232 Connection 3-4 RS485 Connection 3-4 2214 PCB layout 5 RS485 Bus Terminal
More informationGSM CODELOCK ACCESS CONTROL UNIT
GSM CODELOCK ACCESS CONTROL UNIT EIS ENTRY-LOCK Programming Software v.1.4.20160816 Contents 1 FOR YOUR SAFETY...3 2 INTRODUCTION...4 3 EIS ENTRY-LOCK FEATURES AND APPLICATIONS...5 4 START UP...6 5 LED
More informationRacegun Interface Program -RIP This section covers installation and use of the PC-software for the Racegun grip.
Racegun Interface Program -RIP This section covers installation and use of the PC-software for the Racegun grip. This guide is for the RIP version 1.X please visit www.raceguns.dk for an update if you
More information01 Modular Validators
01 Modular Validators 2 Modular validators A6 X8B X6 5 3,5 5 Telecom Z6 C6 X8 P8 Your Partner for Payment Technologies Your Partner for Payment Technologies Introduction 1. AZKOYEN Medios de Pago is a
More informationBillyOne / OryOne Note Validator
BillyOne / OryOne Note Validator Update Instructions Rev. 1.03 PREPARATORY OPERATIONS: 1. Before installing the software, verify that your PC must have the Framework 3.5 from Microsoft. If not, download
More informationST-HVR8704 ST-HVR8708 ST-HVR8716. Professional Digital Video Recorders QUICK START GUIDE
ST-HVR8704 ST-HVR8708 ST-HVR8716 Professional Digital Video Recorders QUICK START GUIDE 1 Thank you for purchasing this SecurityTronix Hybrid Video Recorder! The documentation for this HVR comes in 2 formats;
More informationPICO LOGGING APPLICATION...
1 Table of contents TABLE OF CONTENTS... 2 ABOUT THIS MANUAL... 3 IMPORTANT NOTES... 3 PICO LOGGING APPLICATION... 5 ABOUT THE PICO LOGGING PC APPLICATION... 5 WHERE TO GET A HOLD OF THE PICO LOGGING APPLICATION...
More informationOperating Manual. Version 7.3.4
Operating Manual Version 7.3.4 March 2011 Index Page 1. Installation instructions 4 1.1 System requirements 4 1.2 Installation procedure 4 1.3 Meitav-tec USB adaptor installation 7 2. Open Maxinet and
More informationWVL2 Wireless Vehicle Link 2 Installation and Setup Manual
WVL2 Wireless Vehicle Link 2 Installation and Setup Manual Chapter 1: Introducing the Wireless Vehicle Link 2...1 WVL2 Components...2 Component Checklist...3 Product Specifications...4 System Requirements...5
More informationNational Grid Short Term Operating Reserve System User Manual. National Grid Short Term Operating Reserve System User Manual
National Grid i Contents 1 Introduction... 1-1 1.1 Abbreviations and Glossary... 1-1 1.2 Purpose... 1-1 1.3 Overview... 1-1 2 STOR System Interface... 2-1 2.1 Screen Layout... 2-1 2.2 Colour Indication...
More informationValidator Programming System DA3 Users Manual GA339-2
Validator Programming System DA3 Users Manual GA339-2 Revision History Title: INNOVATIVE TECHNOLOGY LTD DA3 Users Manual Drawing No: GA339 Project: Author: R. Soutter Date: 04/01/2007 Format: MS Word 2000
More informationGSC300 CONFIGURATOR SOFTWARE INTERFACE. Installation and User Manual for the GSC300 Configurator PC Software Interface
GSC300 CONFIGURATOR SOFTWARE INTERFACE Installation and User Manual for the GSC300 Configurator PC Software Interface File: ConfiguratorRev1.5.2.doc Feb.21, 2006 2 READ MANUAL BEFORE INSTALLING UNIT END-USER
More informationDigital Dash I/O Adapter Configuration
Digital Dash I/O Adapter Configuration The I/O Adapter adds ten inputs/outputs to the 7 digital dash. These inputs and outputs can then be configured as gauges or switches, and data logged locally through
More informationChange machine. Operating Manual. Cod. C27-M-DUALP-EN Rev
Dual Coin PRO EN Change machine Operating Manual Cod. C27-M-DUALP-EN Rev. 29 09 2015 GUIDE TO THE SYMBOLS IN THE MANUAL The following symbols are used in this manual in order to facilitate its understanding.
More informationVideo Management Software
Video Management Software User Manual Web: europesecurity.eu Mail: info@europesecurity.eu Tel.: 0541 352 952 User s Manual 2 Contents CHAPTER : XMS CENTRAL USER MANUAL 1 PC REQUIREMENT 3 2 INSTALL 3 3
More informationHART / EtherNet/IP Gateway GT200-HT-EI User Manual V 1.0 REV A SST Automation
HART / EtherNet/IP Gateway GT200-HT-EI V 1.0 REV A SST Automation E-mail: SUPPORT@SSTCOMM.COM WWW.SSTCOMM.COM Catalog 1 Product Overview... 4 1.1 Product Function...4 1.2 Product Features... 4 1.3 Technical
More informationEnter your Appserv username and password to sign in to the Website
Appserv Desktop Access Logging on from a Windows 10 Device Step 1. To sign in to the Appserv Desktop Access website, either enter the following address into the Microsoft Edge browser address bar, or click
More informationTransTech Systems,Inc NE Sky Lane, Suite 130 Aurora, OR Phone: Fax:
TransTech Systems,Inc 12142 NE Sky Lane, Suite 130 Aurora, OR 97002 Phone: 888-843-3643 Fax: 503-682-0166 User Guide Multifeature Reversible Encoder Integration of Smart Card Encoders Evolis Card Printer
More informationUsing TLS3-GD2 Guardlocking Interlock with ArmorBlock Guard I/O and SmartGuard Controller
Safety Application Example Using TLS3-GD2 Guardlocking Interlock with ArmorBlock Guard I/O and SmartGuard Controller Guardlocking with On-machine Components Safety Rating: Category 3, according to EN954-1
More informationHopperOne S11 Std Pulse
HopperOne S11 Std Pulse Operator s manual Rev. 1.02 HopperOne S11 Std Pulse Standard / Reverse Operator s Manual 1. General description Congratulations for your purchase of the Alberici HopperOne S11!
More informationArdac Elite EP Host Manual TSP020.doc Issue 4.2 May 2008
Ardac Elite EP Host Manual TSP020.doc Issue 4.2 May 2008 User Guide Page 1 of 37 Ardac Elite EP User Guide Contents 1 Introduction... 3 2 Getting started... 4 2.1Equipment supplied...4 2.2To power up the
More informationImage Backup and Recovery Procedures For Windows 7
Image Backup and Recovery Procedures For Windows 7 Thank you for purchasing a Fujitsu computer. Fujitsu is committed to bringing you the best computing experience with your new system. It is very important
More informationSchneider Electric License Manager
Schneider Electric License Manager EIO0000001070 11/2012 Schneider Electric License Manager User Manual 12/2012 EIO0000001070.01 www.schneider-electric.com The information provided in this documentation
More informationINSTRUCTION MANUAL ABB Power Quality Link Installation and user guide
INSTRUCTION MANUAL ABB Power Quality Link Installation and user guide Table of contents 1 Introduction... 4 2 Overview... 4 2.1 Introduction to the ABB Power Quality Link software... 4 2.2 Physical layer...
More informationLumina Technical Manual TSP013.doc Issue 4.8 July 2006
This document is the copyright of Money Controls Ltd and may not be reproduced in part or in total by any means, electronic or otherwise, without the written permission of Money Controls Ltd. Money Controls
More information3700 SERIES USER MANUAL
SAFETY GUIDE This manual contains the precautions necessary to ensure your personal safety as well as for protection for the products and the connected equipment. These precautions are highlighted with
More informationUser and installation manual
aquacomputer POWERADJUST 3 User and installation manual poweradjust 3 USB Firmware version 1006 aquasuite version 2016 Current as of October 2016 All information contained in this manual is subject to
More informationPlus-X 300. Installation and Operation Manual
Plus-X 300 Installation and Operation Manual Table of Contents Introduction... 1 Compatibility... 1 Installation... 1 Configuration... 2 Operation... 5 Getting Help... 6 Warranty... 6 Appendix A: Specifications...
More informationUser Manual. Central Monitoring Software for TER-series recorders. CenPro
EN User Manual Central Monitoring Software for TER-series recorders CenPro Contents CENPRO USER MANUAL 1 PC REQUIREMENT 3 2 INSTALL 3 3 UNINSTALL 5 4 BASIC OPERATION 7 4.1 Log In 7 4.2 Screen Layout 8
More informationUser s Guide. Setup+ / Webserver Configuration Tools
User s Guide Setup+ / Webserver Configuration Tools Statements METTLER TOLEDO 2017 No part of this manual may be reproduced or transmitted in any form or by any means, electronic or mechanical, including
More informationHelios PD Large Display Meter Quick Start Guide
MeterView Pro USB Install Thank you for your purchase of the Helios PD2-6000 large display meter. This quick start guide will briefly describe some of the common setup procedures for this meter. This guide
More informationTECHNICAL MANUAL CHEETAH V5 DVI MODULES
TECHNICAL MANUAL CHEETAH V5 DVI MODULES Publication: 81-9059-0611-0, Rev. E September, 2008 Thank You!! for purchasing your new V5 System from QuStream. We appreciate your confidence in our products. QuStream
More informationControlMaster controllers and indicators ConfigPilot
ABB MEASUREMENT & ANALYTICS INSTRUCTION ControlMaster controllers and indicators ConfigPilot Creating, uploading and downloading configurations Measurement made easy 1 Introduction A configuration for
More informationUsbScope.eu Manual. UsbScope.eu Manual. Version channel version
Version 3.1 4 channel version Version 3.1 1 Sept-2011 Table of contents 1 Introduction...3 2 Hardware description...3 2.1 Specifications...3 2.2 PCB layout...4 2.3 Status LED s on 4 channel board...4 3
More informationARES. User s Guide. Aprilia Racing Engine Setup. English version
ARES Aprilia Racing Engine Setup User s Guide English version ARES user s guide 2/59 I. WARNINGS... 6 II. SOFTWARE AND ENGINE CONFIGURATION COMPATIBILITY... 6 III. BEFORE UPDATING ARES TO A NEWER VERSION...
More informationVersion 9.2. Quick Guide. Version 2.0
Version 9.2 Quick Guide Version 2.0 Copyright 1981-2009 Netop Business Solutions A/S. All Rights Reserved. Portions used under license from third parties. Please send any comments to: Netop Business Solutions
More informationDate 18/05/17. Operation and maintenance instructions for driver configurator QSet
Operation and maintenance instructions 28 1. General recommendations The recommendations regarding safe use in this document should be observed at all times. Some hazards can only be associated with the
More informationInstallation and Operation Guide
Installation and Operation Guide CONTENTS EC ))) KEY ))) CONVENIENT SECURITY. YOUR PHONE IS YOUR KEY. 1. Installing ECKey Readers 2 2. Pairing a Phone. 3 3. Triggering the Reader.. 3 4. Bluetooth Modes
More informationMicroprocessor Module Replacement Kit for Multi-Zone Leak Monitors Instruction Manual
621 Hunt Valley Circle New Kensington, PA 15068 3015-5547 Tel: 724-334-5000 Revision 4 Fax: 724-334-5001 May 17, 2013 Microprocessor Module Replacement Kit for Multi-Zone Leak Monitors Instruction Manual
More informationDEPOSITPARTNER INSTALLATION GUIDE Desktop Application
DEPOSITPARTNER INSTALLATION GUIDE Desktop Application SCANNER DRIVER INSTALLATION NOTE: In order for the scanner to work properly, the scanner drivers must be installed before downloading the DepositPartner
More informationNuApps-POE User s Manual
NuApps-POE User s Manual USM V1.1 Foreword Copyright Copyright 2010 Xtramus Technologies, all rights reserved. The information contained in this document is the property of Xtramus Technologies. No part
More informationRapid Test WINDOWS APP User Manual
Rapid Test WINDOWS APP User Manual Version Control Version Number Date Changed by 1 25th August 2016 Nicola Latter 2 15 th September 20016 Nicola Latter 3 27 th October 2016 Nicola Latter 4 8 th December
More informationConfigurator 2.0 Software
Configurator 2.0 Software QUICK REFERENCE MANUAL Super Systems Inc. 7205 Edington Drive Cincinnati, OH 45249 513-772-0060 / 800-666-4330 Fax: 513-772-9466 www.supersystems.com Table of Contents SSi Configurator
More informationRTS ISDN 2002 System. Operator Manual Software Description
RTS ISDN 2002 System Operator Manual Software Description PAGE 1-2 RTS ISDN 2002 System A Publication of EVI Audio GmbH Hirschberger Ring 45 D-94315 Straubing Telephone + 49 9421 706-0 Fax + 49 9421 706-422
More informationDSTHM-2 COMBINED T AND RH DUCT TRANSMITTER. Mounting and operating instructions
Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 4 OPERATIONAL DIAGRAMS 5 WIRING AND
More informationCreone AB Box 148 S Tranås SWEDEN Tel: +46(0) Fax: +46(0) Internet: All data
INSTRUCTION MANUAL Keybox 9000 Basic Keybox 9000 System Keybox 9000 Expansion KeyWin Light Creone AB Box 148 S-573 22 Tranås SWEDEN Tel: +46(0)140-38 61 80 Fax: +46(0)140-38 61 89 E-mail: mailbox@creone.com
More information: DOOR ENTRY UNIT USER MANUAL EIS-LCD. Programming Software
: DOOR ENTRY UNIT EIS-LCD Programming Software v.2.0 2018 Page 1 Contents 1 FOR YOUR SAFETY...5 2 INTRODUCTION...6 3 EIS-LCD, EIS-40 FEATURES AND APPLICATIONS...7 4 START UP...8 5 LED INDICATION...9 6
More informationSC-01 Data Logger Management Program Operator s Manual
SC-01 Data Logger Management Program Operator s Manual Part Number: 71-0138RK Revision: P1 Released: 9/12/07 www.rkiinstruments.com Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by
More informationSOLO NX EXT COMPACT GSM DOOR ENTRY UNIT WITH 1, 2 or 4 CALL BUTTONS
SOLO NX EXT COMPACT GSM DOOR ENTRY UNIT WITH 1, 2 or 4 CALL BUTTONS Contents 1 FOR YOUR SAFETY... 3 2 INTRODUCTION... 4 3 SOLO-NX FEATURES AND APPLICATIONS... 5 4 START UP... 6 5 LED INDICATION... 7 6
More informationPublic Domain Document
Part 2 - Contents 1. Introduction...4 2. Notation...4 2.1 Key...5 3. Command List...6 3.1 Header 255 - Factory set-up and test...6 3.2 Header 254 - Simple poll...6 3.3 Header 253 - Address poll...6 3.4
More informationKingston SecureTraveler User Guide
Kingston SecureTraveler User Guide Thank you for buying a Kingston DataTraveler Hi-Speed certified USB Flash drive. Kingston s DataTraveler products incorporate the latest in Hi-Speed USB 2.0 Flash memory
More informationVisitor Management System Module Settings and Operation Guide
Visitor Management System Module Settings and Operation Guide Visitor Management System Module Settings and Operation Guide. Introduction.. 4 Starting and stopping the Visitor Management System software
More informationGetting Started Guide. Version:
Getting Started Guide Version: 1.2.2. Table of Contents Before You Start... 3 Installing the Remote Deposit application for use with Windows Vista/Windows7... 4 Running Programs in Microsoft Windows Vista/Windows7...
More information12.3 Pro Dash Quick Start Guide
12.3 Pro Dash Quick Start Guide 553-111 CONTENTS: Package Contents... 3 Mounting... 3 Connections... 4 Main Connector... 4 CAN Extension Harness... 6 USB... 7 GPS Antenna... 7 Cleaning... 7 Touchscreen
More informationFacial & Fingerprint Recognition Product
Facial & Fingerprint Recognition Product Series User Manual Version: 1.1.7 Date: January 2010 About This Manual This document introduces the user interface and menu operations of the Facial & Fingerprint
More informationEnCell Battery Cell Monitor
EnCell Battery Cell Monitor Instruction Manual Model RCM15S12 NERC Compliant YO R U H T PA TO Z O R E W O D N M I T E enchargepowersystems.com sales@enchargepowersystems.com (888) 407.5040 Contents 1 Warnings,
More informationUser s. Guide. Integrated Library System. Acquisitions
User s Guide Integrated Library System Acquisitions VIRTUA ILS INTEGRATED LIBRARY SYSTEM Acquisitions User s Guide Version 43.1 January 2004 Copyright 1999-2004 VTLS Inc. All Rights Reserved. Virtua and
More informationInstallation of Hot Disk v 7.3 and later on a PC with Windows 7, 8 or 10
Installation Instruction for Hot Disk TPS 7 2.1 2017-05-09 1(44) Installation of Hot Disk v 7.3 and later on a PC with Windows 7, 8 or 10 Installation Instruction for Hot Disk TPS 7 2.1 2017-05-09 2(44)
More informationWSDA User Guide
User Guide Version 8500-0029 rev. 006 WSDA -1000 User Guide www.microstrain.com Little Sensors, Big Ideas. 2012 by 459 Hurricane Lane, Suite 102 Williston, VT 05495 Phone 802-862-6629 Fax 802-863-4093
More informationMagnetek Material Handling IMPULSE LINK 4.1 Basic Instruction Manual
Magnetek Material Handling IMPULSE LINK 4.1 Basic Instruction Manual February 2006 Part Number: 140-10350 Copyright 2006 Magnetek Material Handling 2005 MAGNETEK MATERIAL HANDLING All rights reserved.
More informationSOLO KP SOLO KP LCD COMPACT MULTI-APARTMENT GSM DOOR ENTRY UNIT USER MANUAL
SOLO KP SOLO KP LCD COMPACT MULTI-APARTMENT GSM DOOR ENTRY UNIT Contents 1 FOR YOUR SAFETY... 4 2 INTRODUCTION... 5 3 SOLO-KP AND SOLO-KP LCD FEATURES AND APPLICATIONS... 6 4 START UP... 7 5 LED INDICATION...
More information2 Product Overview. 5 User Interface. 14 Logging Data. 17 Viewing Data. 19 Managing Data. 24 Device Settings. 26 Specifications.
TITAN S8 Portable Data Acquisition Logger PRODUCT USER GUIDE To view the full MadgeTech product line, visit our website at madgetech.com. TABLE OF CONTENTS 2 Product Overview 5 User Interface 14 Logging
More informationADVANCED OPERATOR PANEL (AOP)
ADVANCED OPERATOR PANEL (AOP) Operating Instructions Issue 04/02 English Contents 1 Warnings and Notes 3 1.1 Special Key Functions 4 2 Applications Examples 4 2.1 Single drive control using the AOP 4 2.2
More informationDriveWizard Plus Instruction Manual
DriveWizard Plus Instruction Manual To properly use the product, read this manual thoroughly. MANUAL NO. TOEP C730600 20C Table of Contents Safety Symbols and Markings...4 Manual Overview...5 Related Manuals...5
More informationBCOM-USB Device. User Manual.
BCOM-USB Device User Manual www.kalkitech.com Version 2.1.2, December 2017 Copyright Notice 2017 Applied Systems Engineering, Inc. All Rights reserved. This user manual is a publication of Applied Systems
More informationAnalog & Digital Output Module Quick Start Guide
Diablo EZReporter Analog & Digital Output Module Quick Start Guide Copyright 2012, Diablo Analytical, Inc. Diablo Analytical EZReporter Software Analog & Digital Output Module Quick Start Guide Copyright
More information: DOOR ENTRY UNIT USER MANUAL EIS-R. Programming Software. v
: DOOR ENTRY UNIT EIS-R Programming Software v.1.4.20161115 Contents 1 FOR YOUR SAFETY...3 2 INTRODUCTION...4 3 EIS-R FEATURES and APPLICATIONS...5 4 START UP...6 5 LED INDICATION...7 6 CONNECTION DIAGRAM...8
More informationBUSINESS LINE COMMPORTAL GUIDE
wowforbusiness.com BUSINESS LINE COMMPORTAL GUIDE WOW! Business BCSE.U.1505.O Business Line CommPortal Guide Table of Contents Getting Started...3 Dashboard...4 Messages and Calls...5 Messages...5 Missed
More informationSoftware Setup Instructions for the Foster Control System used in the Explora Dome Observatories
Software Setup Instructions for the Foster Control System used in the Explora Dome Observatories Contents Pages 3 & 4 The new tic counter system & home position sensor Page 5 Control Boxes Pages 6-8 Down
More informationITALY CUP TECHNICAL SPECIFICATIONS AND USE INSTRUCTIONS OF THE DECONTO CHIPCARD SYSTEM
ITALY CUP TECHNICAL SPECIFICATIONS AND USE INSTRUCTIONS OF THE DECONTO CHIPCARD SYSTEM SGL Italia S.r.l., sole proprietorship, management and coordination by N&W S.p.a., reverses by law the property of
More informationInstruction Sheet WPC 2000 Option 1
Instruction Sheet WPC 2000 Option 1 This document shows you how to install, wire, program, monitor, and troubleshoot WPC 2000 Option 1. Option 1 is compatible with WPC 2000 systems running WPC 2000 version
More informationUsing VPN. Provider Staff
Using VPN Provider Staff 1 Internet Explorer (32-bit) Enter https://vpn.djj.state.fl.us in the address bar You will need to use IE-32bit. 64-bit machines have the IE 64-bit option as well. To check this
More informationSWC1090 configuration software for G.M. International Isolators series D1000 and E1000. Installation and use manual
SWC1090 configuration software for G.M. International Isolators series D1000 and E1000 Installation and use manual ISM0084-2 Installation and use of the SWC1090 calibration software Page 1 of 12 Index
More informationTITAN S8. Portable Data Acquisition Logger. Product User Guide
TITAN S8 Portable Data Acquisition Logger Product User Guide Table of Contents 2 General Features... 3 Device Overview... 3 External Features... 3 Device Orientation... 4 Device Inputs... 5 Sensor Types
More informationGalaxy ACCeSS Lite Downloader
Galaxy ACCeSS Lite Downloader Installation and Operating Instructions Honeywell Security Table of contents Introduction...3 Note for Galaxy 3 series panels V5.0x...3 Installation...4 Set-up...4 Running
More informationREAD ME FIRST Windows 98/ME/2000
READ ME FIRST Windows 98/ME/2000 *DSL Equipment Installation Guide: Alcatel Speed Touch PC *Digital Subscriber Line Part Number: AlcatelPC9x02A Version 1.2-A Table of Contents Follow Steps 1 through 7
More informationRK-LINK TM Version 2.x Instructions
Quick Start Steps Requirements - Windows 95 or Windows NT 4.0 or later, 16MB RAM, 20-30MB Hard Disk, 486 or better processor, Serial COM Port capable of 19.2K Baud. RKAT Module must be installed at the
More informationNortel Communication Server 1000 Using the DMC DECT Manager. Release: 7.0 Document Revision: NN
Release: 7.0 Document Revision: 01.01 www.nortel.com NN43001-142. . Release: 7.0 Publication: NN43001-142 Document release date: 4 June 2010 While the information in this document is believed to be accurate
More informationAMC Manager User's Manual
WA102520XA AMC Manager User's Manual Copyright 2016 silex technology, Inc. All rights reserved. Index 1. Introduction...1 1-1. Introduction...1 Disclaimers...1 Trademarks...1 2. What is AMC Manager?...3
More informationRAIDTech USER S MANUAL. Revised October 3, Features
RAIDTech USER S MANUAL Revised October 3, 2006 Features Simple, hardware-based RAID (levels 0 or 1) On-the-fly data protection: RAID 1 makes backing up as painless as possible. The data is mirrored in
More informationUSB Dog Terminator. User's Manual.
2017 USB Dog Terminator User's Manual www.willem-ua.com USB Dog Terminator. User's Manual. 1 Short description USB DOG Terminator was developed specifically for use in GPU farms and is designed to restart
More information: DOOR ENTRY UNIT USER MANUAL EIS-LCD. Programming Software. v
: DOOR ENTRY UNIT EIS-LCD Programming Software v.1.4.20161115 Page 1 Contents 1 FOR YOUR SAFETY...4 2 INTRODUCTION...5 3 EIS-LCD, EIS-40 FEATURES and APPLICATIONS...6 4 START UP...7 5 LED INDICATION...8
More informationREAD ME FIRST Windows 95/98/Me/2000
READ ME FIRST Windows 95/98/Me/2000 *DSL Equipment Installation Guide: Efficient Networks 5260 *Digital Subscriber Line Part Number: 52609x02 Version 1.2-A Table of Contents Follow Steps 1 through 8 to
More informationContents. 2 Getting Started: Using HOBOware with HOBO Data Loggers
Contents Introduction... 4 An Overview of HOBOware... 5 Installing HOBOware... 6 Before You Begin... 6 License Key... 6 Steps for Windows... 7 Steps for Macintosh... 7 Using the HOBOware Setup Assistant
More informationUsing GuardShield Light Curtains (Safe 4, Micro 400, or 440L), with ArmorBlock Guard I/O and SmartGuard Controller
Safety Application Example Using GuardShield Light Curtains (Safe 4, Micro 400, or 440L), with ArmorBlock Guard I/O and SmartGuard Controller Light Curtain with On-machine Components Safety Rating: Category
More informationCONTROL ROOM SOFTWARE
CONTROL ROOM SOFTWARE Starting QTWatch... Main screen... Control Monitor Screen... Action page... Site Map page... Standard Operations page... Handling calls on Actions... How to log a manual/remote call...
More informationSERIES. ProVu PD6200 Analog Input Rate/Totalizer. Quick Start Guide. MeterView Pro. 233 South Street Hopkinton MA USA
ProVu PD6200 Analog Input Rate/Totalizer MeterView Pro USB Install Thank you for your purchase of the ProVu PD6200 rate/totalizer. This quick start guide will briefly describe some of the common setup
More informationACTpro Single Door IP Controller. Operating & Installation Instructions
ACTpro 1500 Single Door IP Controller Operating & Installation Instructions 18-00079 Issue 1 This manual refers to the ACTpro 1500 a TCP/IP based control unit supporting up to 32 doors. Access Control
More informationField Update Guide. for Raven Viper Pro
Field Update Guide for Raven Viper Pro Introduction The field update kit (P/N 117-0171-467) is designed to allow the Raven Viper Pro to utilize the automatic power down feature without returning the console
More information