Server Support Matrix ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for Oracle Solaris

Size: px
Start display at page:

Download "Server Support Matrix ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for Oracle Solaris"

Transcription

1

2

3 Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000 model 700, 800, 900, 1100, 1200, 2100, or 2200 Disk storage system to a server running Solaris OS and using Sun Fibre Channel cards via a Fibre Channel interface. This document should be used in conjunction with any other applicable user manuals, such as those for the ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000 model 700, 800, 900, 1100, 1200, 2100, or 2200 Disk storage system, server, OS used, Fibre Channel cards, drivers, etc. Note that this manual refers the following documents. Server Support Matrix ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for Oracle Solaris Also, note that in this document the ETERNUS2000 models 100 and 200, ETERNUS4000 models 300, 400, 500, and 600, and ETERNUS8000 models 700, 800, 900, 1100, 1200, 2100, and 2200 Disk storage systems are collectively referred to as ETERNUS Disk storage systems. Fifth Edition December 2010 The Contents and Structure of this Manual This document is composed of the following five chapters and an appendix. Chapter 1 Workflow This describes the workflow required to establish a connection between a server with Sun Fibre Channel cards and an ETERNUS Disk storage system. Chapter 2 Installing the Fibre Channel Card Driver This describes how to install the Fibre Channel card driver. Chapter 3 Setting Up the Server This describes how to set up the server for different connection topologies. Chapter 4 Logical Unit Recognition This describes how to make the server recognize the ETERNUS Disk storage system LUNs (logical units). Chapter 5 Required Driver Parameters This describes how to set up the Sun Fibre Channel card driver for use with Emulex OEM Fibre Channel cards. 3

4 Preface An appendix contains the various management tables that are used in "Chapter 3 Setting Up the Server". Safe Use of this Product Using this manual This manual contains important information to ensure the safe use of this product. Be sure to thoroughly read and understand its contents before using the product. After reading, store this manual in a safe place for future reference. FUJITSU has made every effort to ensure the safety of the users and other personnel, and to prevent property damage. When using this product, carefully follow the instructions described in this manual. Acknowledgments Oracle and Java are registered trademarks of Oracle and/or its affiliates. All SPARC trademarks are used under license and are trademarks or registered trademarks of SPARC International, Inc. in the United States and other countries. Emulex is a trademark of Emulex Corp. QLogic is a trademark of QLogic Corp. The company names, product names and service names mentioned in this document are registered trademarks or trademarks of their respective companies. Naming Conventions Product names Oracle Solaris might be described as Solaris, Solaris Operating System, or Solaris OS. Other names "Channel Adapter" (CA) refers to the Fibre Channel interface module used in the ETERNUS Disk storage systems to connect to the server. "Fibre Channel card" refers to the Fibre Channel interface module normally used by the server. A "Host Bus Adapter" (HBA) or "Channel Adapter" (CA) may be used instead, depending on the server. Italics are used to show variables such as values and characters that appear in command parameters and output examples. 4

5 Contents Chapter 1 Workflow...6 Chapter 2 Installing the Fibre Channel Card Driver...8 Chapter 3 Setting Up the Server Sun Driver For QLogic OEM Fibre Channel Cards Creating a WWN Instance Management Table for the Server Setting the Configuration File (/etc/system) Sun Driver For Emulex OEM Fibre Channel Cards Creating a WWN Instance Management Table for the Server Setting the Configuration File (/kernel/drv/emlxs.conf) Setting the Configuration File (/etc/system) Chapter 4 Logical Unit Recognition For FC-AL Connection For Fabric Connection Chapter 5 Required Driver Parameters Emulex OEM Fibre Channel Card Setup /kernel/drv/emlxs.conf Parameter List /kernel/drv/emlxs.conf Example Appendix A Management Table Template...29 A.1 WWN Instance Management Table for the Server

6 Chapter 1 Workflow This manual is used when performing the setup procedure described in "Installing the Driver and Setting Up the Server" and "Logical Unit Recognition" of the "ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for Oracle Solaris". Workflow Fiber Channel Card Driver Installation Refer Install the driver. Download the proper driver from the Oracle web-site as required. - "Chapter 2 Installing the Fibre Channel Card Driver" (page 8) - Used for driver installation Driver (downloaded from the Oracle web-site) Various Management Table Creation Refer Enter necessary information in "WWN Instance Management Table for the Server". - "Chapter 3 Setting Up the Server" (page 9) - "Appendix A Management Table Template" (page 29) Fiber Channel Card Driver Setup Refer Set the driver parameters by editing the configuration file. - "Chapter 3 Setting Up the Server" (page 9) - "Chapter 5 Required Driver Parameters" (page 23) - Check the Sun driver notes "ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for Oracle Solaris" 6

7 Chapter 1 Workflow > Logical Unit (LUN) Recognition Make the server recognize the ETERNUS Disk storage system logical units using the ssd driver. Refer - "Chapter 4 Logical Unit Recognition" (page 20) After completing all the required procedures in this manual, proceed to "Setting the Multipaths" in "ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for Oracle Solaris". 7

8 Chapter 2 Installing the Fibre Channel Card Driver Install the Fibre Channel card driver. Required procedure varies depending on the Solaris OS version. Refer to the following Oracle web-site for installation procedures. Solaris 10 OS Driver installation is not necessary because the OS-bundled driver is used. Solaris 9 OS or Solaris 8 OS Download and install the appropriate driver from the Oracle web-site. 8

9 Chapter 3 Setting Up the Server The server setup will vary according to how the ETERNUS Disk storage systems and server are to be connected. There are two possible connection topologies: FC-AL connection and Fabric connection. Edit the server's configuration file to match the chosen topology. Configuration files may also differ depending on which Fibre Channel cards are to be used. Check the Fibre Channel card product ID in the following table and follow the procedure detailed in the indicated section ("3.1 Sun Driver For QLogic OEM Fibre Channel Cards" (page 10) or "3.2 Sun Driver For Emulex OEM Fibre Channel Cards" (page 15)). Procedure Supplier Fibre Channel card product ID "3.1 Sun Driver For QLogic OEM Fibre Channel Cards" (page 10) Fujitsu Sun SE0X7F22X SE0X7F21X XSPFC212A XSPFC211A XSPFC202A XSPFC201A X6799A X6768A X6767A X6727A SG-XPCIE2FC-QF8-Z SG-XPCIE1FC-QF8-Z SG-XPCIE2FC-QF4 SG-XPCIE1FC-QF4 SG-XPCI2FC-QF4 SG-XPCI1FC-QF4 SG-XPCI2FC-QF2-Z SG-XPCI2FC-QF2 SG-XPCI1FC-QF2 SG-XPCI1FC-QL2 9

10 Chapter 3 Setting Up the Server > 3.1 Sun Driver For QLogic OEM Fibre Channel Cards Procedure Supplier Fibre Channel card product ID "3.2 Sun Driver For Emulex OEM Fibre Channel Cards" (page 15) Fujitsu Sun XSEFC402AF XSEFC401AF XSEFC402A XSEFC401A SG-XPCIE2FC-EM8-Z SG-XPCIE1FC-EM8-Z SG-XPCI2FC-EM4-Z SG-XPCI1FC-EM4-Z SG-XPCE2FC-EM4 SG-XPCE1FC-EM4 SG-XPCI2FC-EM2 SG-XPCI1FC-EM2 3.1 Sun Driver For QLogic OEM Fibre Channel Cards When connecting using QLogic OEM Fibre Channel cards with a Sun Fibre Channel card driver, the configuration file will need to be edited as follows. The "command queue depth" setting must be adjusted for both FC-AL connection and Fabric connection. The "command queue depth" setting is specified in the configuration file (/etc/system). For FC-AL connection Instance name data of the Fibre Channel card is necessary. Refer to the following to set. "3.1.1 Creating a WWN Instance Management Table for the Server" (page 11) "3.1.2 Setting the Configuration File (/etc/system)" (page 13) For Fabric connection The Fibre Channel card Instance name, target WWN, and target ID information are necessary. Check each item and enter them in the list. Edit the configuration file according to those information and make settings. Refer to the following to set. "3.1.1 Creating a WWN Instance Management Table for the Server" (page 11) "3.1.2 Setting the Configuration File (/etc/system)" (page 13) 10

11 Chapter 3 Setting Up the Server > 3.1 Sun Driver For QLogic OEM Fibre Channel Cards Creating a WWN Instance Management Table for the Server Create a "WWN instance management table for the server" with information regarding the Fibre Channel card installed in the server. For each Fibre Channel cards installed in the server, check the physical slot names, WWN, instance names, physical path names, and controller number of the target connected to the Fibre Channel card and enter them in the "WWN instance management table for the server" (provided in "Appendix A Management Table Template" (page 29)). WWN Instance Management Table for the Server Physical slot name WWN Controller number Instance name Physical path name Procedure 1 Check the instance name. "qlc + instance number" is the format used to represent Fibre Channel card instance names. The instance No. that corresponds to the physical path in which the Fibre Channel card is installed is stored in the "/etc/path_to_inst" file at Fibre Channel card driver installation. Extract necessary parts using the "grep" command. grep "qlc" /etc/path_to_inst Example grep "qlc" /etc/path_to_inst "/pci@9,600000/sunw,qlc@1" 0 "qlc" "/pci@9,600000/sunw,qlc@2" 1 "qlc" Physical path name Instance number 2 Enter the results in "Instance name" and "Physical path name" columns of the "WWN instance management table for the server". Example Physical slot name WWN Controller number Instance name Physical path name qlc0 /pci@9,600000/sunw,qlc@1 qlc1 /pci@9,600000/sunw,qlc@2 11

12 Chapter 3 Setting Up the Server > 3.1 Sun Driver For QLogic OEM Fibre Channel Cards 3 Enter the slot number of the Fibre Channel card installed in the server in the "Physical slot number" field of the "WWN instance management table for the server". Use the "/usr/platform/`uname -i`/sbin/prtdiag -v" command to check the installed Fibre Channel card slot number. Example: Excerpt from "/usr/platform/sunw,sparc-enterprise-t5220/sbin/prtdiag -v" output /usr/platform/sunw,sparc-enterprise-t5220/sbin/prtdiag -v ========================= IO Configuration ================================================= Location Type Slot Path Name Model MB/PCIE1 PCIE 1 /pci@9,600000/sunw,qlc@2 SUNW,qlc-pciex1077,2432 QLE2460 MB/PCIE0 PCIE 0 /pci@9,600000/sunw,qlc@1 SUNW,qlc-pciex1077,2432 QLE2460 Physical slot WWN Controller number Instance name Physical path name PCIE 0 qlc0 /pci@9,600000/sunw,qlc@1 PCIE 1 qlc1 /pci@9,600000/sunw,qlc@2 4 Check the WWN for the Fibre Channel card. 4-1 Use the following command to check the display order of the Fibre Channel card physical path names. prtpicl -v -c scsi-fcp grep devfs-path Example prtpicl -v -c scsi-fcp grep devfs-path :devfs-path /pci@9,600000/sunw,qlc@1 :devfs-path /pci@9,600000/sunw,qlc@2 4-2 Use the following command to check the WWN of the Fibre Channel card that corresponds to the physical path name. The result is displayed in the same order as shown in Step 4-1. prtpicl -v -c scsi-fcp grep port-wwn Example prtpicl -v -c scsi-fcp grep port-wwn :port-wwn e0 8b 12 6d 70 :port-wwn e0 8b 16 cf fd 5 Add the results in the "WWN instance management table for the server". Example Physical slot name WWN Controller number Instance name Physical path name PCIE e08b126d70 qlc0 /pci@9,600000/sunw,qlc@1 PCIE e08b16cffd qlc1 /pci@9,600000/sunw,qlc@2 12

13 Chapter 3 Setting Up the Server > 3.1 Sun Driver For QLogic OEM Fibre Channel Cards 6 Check the controller number of the target connected to the Fibre Channel card. Use the following command to check the controller number of the target connected to the Fibre Channel card. The controller number can be checked by searching for the physical path that was confirmed in Step 4-1. cfgadm -v Example cfgadm -v Ap_Id Receptacle Occupant Condition Information When Type Busy Phys_Id c4 connected unconfigured unknown unavailable fc-fabric n /devices/pci@9,600000/sunw,qlc@1/fp@0,0:fc c5 connected unconfigured unknown unavailable fc-fabric n /devices/pci@9,600000/sunw,qlc@2/fp@0,0:fc 7 Add the results in the "WWN instance management table for the server". Physical slot name WWN Controller number Instance name Physical path name PCIE e08b126d70 c4 qlc0 /pci@9,600000/sunw,qlc@1 PCIE e08b16cffd c5 qlc1 /pci@9,600000/sunw,qlc@2 End of procedure This completes the "WWN instance management table for the server" Setting the Configuration File (/etc/system) Procedure 1 Edit the configuration file. Edit the configuration file (/etc/system) and specify the command queue depth. The appropriate command queue depth is determined by the ETERNUS Disk storage system model, as follows: ETERNUS Disk storage system Command queue depth setting ETERNUS ETERNUS ETERNUS The parameter to be specified is determined by the CPU which is installed in the server to be connected. 13

14 Chapter 3 Setting Up the Server > 3.1 Sun Driver For QLogic OEM Fibre Channel Cards For SPARC Specify the command queue depth for the "ssd_max_throttle" parameter. Add this parameter if it does not exist. Example: set ssd:ssd_max_throttle = 20 For x86 Specify the command queue depth for the "sd_max_throttle" parameter. Add this parameter if it does not exist. Example: set sd:sd_max_throttle = 20 2 After editing the configuration file, save it. 3 After the setting is complete, check the configuration file for incorrect settings. 4 Reboot the server. /usr/sbin/shutdown -y -g0 -i6 End of procedure 14

15 Chapter 3 Setting Up the Server > 3.2 Sun Driver For Emulex OEM Fibre Channel Cards 3.2 Sun Driver For Emulex OEM Fibre Channel Cards When connecting using an Emulex OEM Fibre Channel card and Sun Fibre Channel card driver, the configuration file will need to be edited as follows. For FC-AL connection and Fabric connection, the "command queue depth" setting must be adjusted. The "command queue depth" setting is specified in the configuration file (/etc/system). For FC-AL connection Instance name data of the Fibre Channel card is necessary. Refer to the following to set. "3.2.1 Creating a WWN Instance Management Table for the Server" (page 15) "3.2.2 Setting the Configuration File (/kernel/drv/emlxs.conf)" (page 18) "3.2.3 Setting the Configuration File (/etc/system)" (page 18) For Fabric connection The Fibre Channel card Instance name, target WWN, and target ID information are necessary. Check each item and enter them in the list. Edit the configuration file according to those information and make settings. Refer to the following to set. "3.2.1 Creating a WWN Instance Management Table for the Server" (page 15) "3.2.2 Setting the Configuration File (/kernel/drv/emlxs.conf)" (page 18) "3.2.3 Setting the Configuration File (/etc/system)" (page 18) Creating a WWN Instance Management Table for the Server Create a "WWN instance management table for the server" with information regarding the Fibre Channel card installed in the server. For each Fibre Channel cards installed in the server, check the physical slot names, WWN, instance names, physical path names, and controller number of the target connected to the Fibre Channel card and enter them in the "WWN instance management table for the server" (provided in "Appendix A Management Table Template" (page 29)). WWN Instance Management Table for the Server Physical slot name WWN Controller number Instance name Physical path name 15

16 Chapter 3 Setting Up the Server > 3.2 Sun Driver For Emulex OEM Fibre Channel Cards Procedure 1 Check the instance name. "emlxs + instance number" is the format used to represent Fibre Channel card instance names. The instance No. that corresponds to the physical path in which the Fibre Channel card is installed is stored in the "/etc/path_to_inst" file at Fibre Channel card driver installation. Extract necessary parts using the "grep" command. grep "emlxs" /etc/path_to_inst "/pci@9,600000/sunw,emlxs@1" 0 "emlxs" "/pci@9,600000/sunw,emlxs@1,1" 1 "emlxs" Physical path name Instance number 2 Enter the results in "Instance name" and "Physical path name" columns of the "WWN instance management table for the server". Physical slot name WWN Controller number Instance name Physical path name emlxs0 /pci@9,600000/sunw,emlxs@1 emlxs1 /pci@9,600000/sunw,emlxs@1,1 3 Enter the slot number of the Fibre Channel card installed in the server in the "Physical slot number" field of the "WWN instance management table for the server". Use the "/usr/platform/`uname -i`/sbin/prtdiag" command to check the installed Fibre Channel card slot number. Example: Excerpt from "/usr/platform/sunw,sparc-enterprise-t5220/sbin/prtdiag" output /usr/platform/sunw,sparc-enterprise-t5220/sbin/prtdiag ========================= IO Configuration ================================================= Location Type Slot Path Name Model MB/PCIE1 PCIE 1 /pci@9,600000/sunw,emlxs@1,1 SUNW,emlxs-pci10df,fd+LP11002-M4 MB/PCIE0 PCIE 0 /pci@9,600000/sunw,emlxs@1 SUNW,emlxs-pci10df,fd+LP11002-M4 Physical slot name WWN Controller number Instance name Physical path name PCIE 0 emlxs0 /pci@9,600000/sunw,emlxs@1 PCIE 1 emlxs1 /pci@9,600000/sunw,emlxs@1,1 16

17 Chapter 3 Setting Up the Server > 3.2 Sun Driver For Emulex OEM Fibre Channel Cards 4 Check the WWN for the Fibre Channel card. 4-1 Use the following command to check the WWN that corresponds to the Fibre Channel card instance name. prtpicl -v -c scsi-fcp grep devfs-path Example prtpicl -v -c scsi-fcp grep devfs-path :devfs-path /pci@9,600000/sunw,emlxs@1 :devfs-path /pci@9,600000/sunw,emlxs@1,1 :devfs-path /pci@9,600000/sunw,emlxs@2 :devfs-path /pci@9,600000/sunw,emlxs@2,1 4-2 Use the following command to check the WWN of the Fibre Channel card that corresponds to the physical path name. cat /var/adm/messages grep emlxs0 Example cat /var/adm/messages grep emlxs0 Sep 12 09:46:50 sfv890b emlxs: [ID kern.info] [B.125B]emlxs0: NOTICE: 100: Driver attach. (WWPN: C94CDC42 WWNN: C94CDC42) cat /var/adm/messages grep emlxs1 Sep 12 09:47:15 sfv890b emlxs: [ID kern.info] [B.125B]emlxs1: NOTICE: 100: Driver attach. (WWPN: C94CDC43 WWNN: C94CDC43) 5 Add the results in the "WWN instance management table for the server". Physical slot name WWN Controller number Instance name Physical path name C94CDC42 emlxs0 /pci@9,600000/sunw,emlxs@ C94CDC43 emlxs1 /pci@9,600000/ SUNW,emlxs@1,1 6 Check the controller number of the target connected to the Fibre Channel card. Use the following command to check the controller number of the target connected to the Fibre Channel card. cfgadm -v Example cfgadm -v Ap_Id Receptacle Occupant Condition Information When Type Busy Phys_Id c4 connected unconfigured unknown unavailable fc-fabric n /devices/pci@9,600000/sunw,emlxs@1/fp@0,0:fc c5 connected unconfigured unknown unavailable fc-fabric n /devices/pci@9,600000/sunw,emlxs@1,1/fp@0,0:fc 17

18 Chapter 3 Setting Up the Server > 3.2 Sun Driver For Emulex OEM Fibre Channel Cards 7 Add the results in the "WWN instance management table for the server". Physical slot name WWN Controller number Instance name Physical path name C94CDC42 C4 emlxs0 /pci@9,600000/sunw,emlxs@ C94CDC43 C5 emlxs1 /pci@9,600000/ SUNW,emlxs@1,1 End of procedure This completes the "WWN instance management table for the server" Setting the Configuration File (/kernel/drv/emlxs.conf) Set the "topology" and "link speed" by editing the configuration file "/kernel/drv/ emlxs.conf". For setting procedure and parameters, refer to "Chapter 5 Required Driver Parameters" (page 23) Setting the Configuration File (/etc/system) Procedure 1 Edit the configuration file. Edit the configuration file (/etc/system) and specify the command queue depth. The appropriate command queue depth is determined by the ETERNUS Disk storage system model, as follows: ETERNUS Disk storage system Command queue depth setting ETERNUS ETERNUS ETERNUS The parameter to be specified is determined by the CPU which is installed in the server to be connected. For SPARC Specify the command queue depth for the "ssd_max_throttle" parameter. Add this parameter if it does not exist. Example: set ssd:ssd_max_throttle = 20 18

19 Chapter 3 Setting Up the Server > 3.2 Sun Driver For Emulex OEM Fibre Channel Cards For x86 Specify the command queue depth for the "sd_max_throttle" parameter. Add this parameter if it does not exist. Example: set sd:sd_max_throttle = 20 2 Save the configuration file. 3 After the setting is complete, check the configuration file for incorrect settings. 4 Reboot the server. /usr/sbin/shutdown -y -g0 -i6 End of procedure 19

20 Chapter 4 Logical Unit Recognition The ssd driver needs to be set to allow the server to recognize the ETERNUS Disk storage systems' logical units. If Sun Fibre Channel cards are used, the logical unit recognition method will depend on the ETERNUS Disk storage systems to server connection topology. There are two possible connection topologies: FC-AL connection and Fabric connection. 4.1 For FC-AL Connection Confirm that the logical units have been correctly recognized by servers. Procedure 1 Use the following command to confirm that the storage system has been correctly recognized. cfgadm -al cfgadm -al Ap_Id Type Receptacle Occupant Condition c4 fc-private connected configured unknown c4::21ff00e000a8ffaf disk connected configured unknown c5 fc-private connected configured unknown c5::25ff00e000a8ffaf disk connected configured unknown ETERNUS Disk storage system CA (WWN:25ff00e000a8ffaf) has been connected to the Fibre Channel card port with controller number "c5". 2 Use the following command to confirm that the storage system and all the logical units have been correctly recognized. format 20

21 Chapter 4 Logical Unit Recognition > 4.2 For Fabric Connection ETERNUS8000 target ID=16, lun=0 and 1 are connected to physical path /pci@9,600000/sunw,qlc@1 format and c4t16d0 and c4t16d1 are assigned to each of these LUNs. Searching for disks...done c4t16d0: configured with capacity of 7.98GB c4t16d1: configured with capacity of 7.98GB c5t16d0: configured with capacity of 7.98GB c5t16d1: configured with capacity of 7.98GB AVAILABLE DISK SELECTIONS: 0. c1t0d0 <SUN36G cyl alt 2 hd 27 sec 107> /pci@8,600000/sunw,qlc@2/fp@0,0/ssd@w cf6851ce,0 1. c4t16d0 <FUJITSU-E cyl 1022 alt 2 hd 64 sec 256> /pci@9,600000/sunw,qlc@1/fp@0,0/ssd@w21ff00e000a8ffaf,0 2. c4t16d1 <FUJITSU-E cyl 1022 alt 2 hd 64 sec 256> /pci@9,600000/sunw,qlc@1/fp@0,0/ssd@w21ff00e000a8ffaf,1 3. c5t16d0 <FUJITSU-E cyl 1022 alt 2 hd 64 sec 256> /pci@9,600000/sunw,qlc@2/fp@0,0/ssd@w25ff00e000a8ffaf,0 4. c5t16d1 <FUJITSU-E cyl 1022 alt 2 hd 64 sec 256> /pci@9,600000/sunw,qlc@2/fp@0,0/ssd@w25ff00e000a8ffaf,1 Specify disk (enter its number): End of procedure 4.2 For Fabric Connection Use the following commands to enable the server to access the logical units. Procedure 1 Use the following command to identify the paths to the ETERNUS Disk storage system that is being connected. cfgadm -al Example cfgadm -al Ap_Id Type Receptacle Occupant Condition c4 fc-fabric connected unconfigured unknown c4::21ff00e000a8ffaf disk connected unconfigured unknown c5 fc-fabric connected unconfigured unknown c5::25ff00e000a8ffaf disk connected unconfigured unknown 2 Use the following command for each path obtained in Step 1. Repeat this step for all paths to be used. cfgadm -c configure path_obtained_in_step1 21

22 Chapter 4 Logical Unit Recognition > 4.2 For Fabric Connection Example cfgadm -c configure c4::21ff00e000a8ffaf cfgadm -c configure c5::25ff00e000a8ffaf 3 Use the following command to confirm that the paths to the ETERNUS Disk storage system are now usable. "Occupant" status changes from "unconfigured" to "configured". cfgadm -al cfgadm -al Ap_Id Type Receptacle Occupant Condition c4 fc-fabric connected configured unknown c4::21ff00e000a8ffaf disk connected configured unknown c5 fc-fabric connected configured unknown c5::25ff00e000a8ffaf disk connected configured unknown ETERNUS Disk storage system CA (WWN:25ff00e000a8ffaf) has been connected to the Fibre Channel card port with controller number "c5". 4 Use the following command to confirm that the storage system and all the logical units have been correctly recognized. format Target ID=250000E000A8FFAF, lun=0 and 1 are connected and c5t250000e000a8ffafd0 and c5t250000e000a8ffafd1 are format assigned to each of these LUNs. Searching for disks...done c4t16d0: configured with capacity of 7.98GB c4t16d1: configured with capacity of 7.98GB c5t16d0: configured with capacity of 7.98GB c5t16d1: configured with capacity of 7.98GB AVAILABLE DISK SELECTIONS: 0. c1t0d0 <SUN36G cyl alt 2 hd 27 sec 107> /pci@8,600000/sunw,qlc@2/fp@0,0/ssd@w cf6851ce,0 1. c4t210000e000a8ffafd0 <FUJITSU-E cyl 1022 alt 2 hd 64 sec 256> /pci@9,600000/sunw,qlc@1/fp@0,0/ssd@w210000e000a8ffaf,0 2. c4t210000e000a8ffafd1 <FUJITSU-E cyl 1022 alt 2 hd 64 sec 256> /pci@9,600000/sunw,qlc@1/fp@0,0/ssd@w210000e000a8ffaf,1 3. c5t250000e000a8ffafd0 <FUJITSU-E cyl 1022 alt 2 hd 64 sec 256> /pci@9,600000/sunw,qlc@2/fp@0,0/ssd@w250000e000a8ffaf,0 4. c5t250000e000a8ffafd1 <FUJITSU-E cyl 1022 alt 2 hd 64 sec 256> /pci@9,600000/sunw,qlc@2/fp@0,0/ssd@w250000e000a8ffaf,1 Specify disk (enter its number): End of procedure 22

23 Chapter 5 Required Driver Parameters 5.1 Emulex OEM Fibre Channel Card Setup If a Sun driver for a Sun Fibre Channel card (Emulex OEM) is used, the parameters of the "/kernel/drv/emlxs.conf" configuration file need to be edited using the "vi" command. Edit the file in accordance with the "5.1.1 /kernel/drv/emlxs.conf Parameter List" (page 24). The old configuration file should always be backed up before editing: Example cp /kernel/drv/emlxs.conf./emlxs.conf.backup Instance names are specified for some item names, but not for others. Confirm the X part of "emlxsx" with the /var/adm/messages file or the /etc/path_to_inst file. The following examples show the two confirmation methods: Example 1 Check with the "/var/adm/messages" file. "emlxs0" shows an instance name and instance number. Aug155:59:27 sfv890a genunix: [ID kern.info] "emlxs0" is /pci@9,600000/fibre-channel@1 Aug 15 15:59:27 sfv890a emlxs: [ID kern.info] [B.03F0]emlxs0: NOTICE: 720: Link up (2Gb,fabric *) Example 2 Check with the "/etc/path_to_inst". "/pci@9,600000" 3 "pcisch" "/pci@9,600000/fibre-channel@1" 0 "emlxs" "/pci@9,600000/fibre-channel@1/fp@0,0" 0 "fp" Instance number Instance name 23

24 Chapter 5 Required Driver Parameters > 5.1 Emulex OEM Fibre Channel Card Setup /kernel/drv/emlxs.conf Parameter List Parameter Value (for FC-AL connection) *1: "emlxsx-link-speed" setting value Value (for Fabric connection) Initial value emlxsx instance name Remarks num-iocbs ub-bufs network-on emlxsx-topology Yes An instance name is specified for each instance. emlxsx-linkspeed 2, 4, or 8 2, 4, or 8 0 Yes An instance name is specified for each instance. (*1) ack cr-delay cr-count assign-alpa 0x00 0x00 0x00 adisc-support pm-support num-nodes Fibre Channel card transfer speed Fabric connection Fibre Channel switch transfer speed FC-AL connection CA transfer speed 8Gbps 4Gbps 2Gbps 8Gbps 4Gbps 8Gbps Gbps Gbps

25 Chapter 5 Required Driver Parameters > 5.1 Emulex OEM Fibre Channel Card Setup /kernel/drv/emlxs.conf Example The following is a Fabric connection example. COPYRIGHT Emulex. All rights reserved. Solaris LightPulse emlxs driver: global initialized data. console-notices: Sets the verbose level for driver notices to the console. console-warnings: Sets the verbose level for driver warnings to the console. console-errors: Sets the verbose level for driver errors to the console. log-notices: Sets the verbose level for driver notices to the system log file*. log-warnings: Sets the verbose level for driver warnings to the system log file*. log-errors: Sets the verbose level for driver errors to the system log file*. *NOTE: The system log file is normally found at /var/adm/messages. Each parameter is a bit mask that enables/disables specific types of messages. If the bit is set, then the messages of that type are enabled. The available message types are listed below: LOG_MISC 0x /* Misc events */ LOG_DRIVER 0x /* Driver attach and detach events */ LOG_INIT 0x /* HBA initialization events */ LOG_MEM 0x /* Memory management events */ LOG_SLI 0x /* Service Level Interface (SLI) events */ LOG_MBOX 0x /* Mailbox events */ LOG_NODE 0x /* Node events */ LOG_LINK 0x /* Link events */ LOG_ELS 0x /* ELS events */ LOG_PKT 0x /* General I/O packet events */ LOG_FCP 0x /* FCP traffic events */ LOG_TGTM 0x /* FCP target mode events */ LOG_IP 0x /* IP traffic events */ LOG_SFS 0x /* SFS events */ LOG_IOCTL 0x /* IOCtl events */ LOG_FIRMWARE 0x /* Firmware download events */ LOG_CT 0x /* CT events */ LOG_FCSP 0x /* FCSP events */ LOG_RESERVED 0xfffc0000 /* Reserved for future use */ Range: Min:0 Max:0xffffffff console-notices = 0; (Default) console-warnings = 0; (Default) console-errors = 0; (Default) log-notices = 0xffffffff; (Default) log-warnings = 0xffffffff; (Default) log-errors = 0xffffffff; (Default) 25

26 Chapter 5 Required Driver Parameters > 5.1 Emulex OEM Fibre Channel Card Setup console-notices=0; console-warnings=0; console-errors=0; log-notices=0xffffffff; log-warnings=0xffffffff; log-errors=0xffffffff; num-iocbs: Sets the number of iocb buffers to allocate. Range: Min:128 Max:10240 Default:1024 num-iocbs=1024; ub-bufs: Sets the number of unsolicited buffers to be allocated. Range: Min:40 Max:16320 Default:1000 ub-bufs=1000; +++ Variables relating to IP networking support. +++ network-on: Enable/Disable IP networking support in the driver. 0 = Disables IP networking support in the driver. 1 = Enables IP networking support in the driver. Range: Min:0 Max:1 Default:1 network-on=1; +++ Fibre Channel specific parameters +++ topology: link topology for initializing the Fibre Channel connection. 0 = attempt loop mode, if it fails attempt point-to-point mode 2 = attempt point-to-point mode only 4 = attempt loop mode only 6 = attempt point-to-point mode, if it fails attempt loop mode Set point-to-point mode if you want to run as an N_Port. Set loop mode if you want to run as an NL_Port. Range: Min:0 Max:6 Default:0 For FC-AL connection,emlxs0-topology=4; topology=0; emlxs0-topology=2; emlxs1-topology=2; link-speed: Sets the link speed setting for initializing the Fibre Channel connection. 0 = auto select 1 = 1 Gigabaud 2 = 2 Gigabaud 4 = 4 Gigabaud 8 = 8 Gigabaud Range: Min:0 Max:8 Default:0 For both FC-AL and Fabric connections, add these settings. link-speed=0; emlxs0-link-speed=8; emlxs1-link-speed=8; ack0: Determines if ACK0 is used instead of ACK1 for class 2 acknowledgement. 0 = The driver will use ACK1 for class 2 acknowledgement. 1 = The driver will use ACK0 for class 2 acknowledgement. 26

27 Chapter 5 Required Driver Parameters > 5.1 Emulex OEM Fibre Channel Card Setup Range: Min:0 Max:1 Default:0 ack0=0; cr-delay: Sets the coalesce response delay in the adapter. This value specifies a count of milliseconds after which an interrupt response is generated if cr-count has not been satisfied. This value is set to 0 to disable the Coalesce Response feature as default. Range: Min:0 Max:63 Default:0 cr-delay=0; cr-count: Sets the coalesce response count in the adapter. This value specifies a count of I/O completions after which an interrupt response is generated. This feature is disabled if cr-delay is set to 0. Range: Min:1 Max:255 Default:1 cr-count=1; assign-alpa: Sets a preferred ALPA for the adapter. This is only valid if topology is loop. A zero setting means no preference. If multiple adapter instances on the same host are on the same loop, you will want to set this value differently for each adapter. For example: emlxs0-assign-alpa=0x01; assigns ALPA 0x01 to adapter 0 emlxs1-assign-alpa=0x02; assigns ALPA 0x02 to adapter 1 emlxs2-assign-alpa=0x04; assigns ALPA 0x04 to adapter 2 Range: Min:0x00 Max:0xef Default:0x00 (valid ALPA s only) assign-alpa=0x00; adisc-support: Sets the ADISC login support level. This sets the level of driver support for the Fibre Channel ADISC login I/O recovery method. 0 = No support. Flush active I/O s for all FCP target devices at link down. 1 = Partial support. Flush I/O s for non-fcp2 target devices at link down. 2 = Full support. Hold active I/O s for all devices at link down. Range: Min:0 Max:2 Default:1 adisc-support=1; pm-support: Enable/Disable power management support in the driver. 0 = Disables power management support in the driver. 1 = Enables power management support in the driver. Range: Min:0 Max:1 Default:0 pm-support=0; num-nodes: Number of fibre channel nodes (NPorts) the driver will support. 0 = Indicates auto detect limit of adapter. Range: Min:0 Max:4096 Default:0 num-nodes=0; pci-max-read: Sets the PCI-X max memory read byte count on the adapter. This value controls the adapter s max PCI-X memory read count. On Sunfire x4100/4200 systems this parameter must be changed to 1024 bytes. Currently, this parameter should only be modified on Sunfire x4100/4200 systems due to the unique nature of the PCI-X bus on these systems, otherwise it should be left as default. Options: 512, 1024, 2048, 4096 Range: Min:512 Max:4096 Default:

28 Chapter 5 Required Driver Parameters > 5.1 Emulex OEM Fibre Channel Card Setup *Uncomment this parameter for Sunfire x4100/4200 systems only pci-max-read=1024; linkup-delay: Sets the linkup delay period (seconds) after initialization. This value controls how long the driver waits for the Fibre Channel link to come up after an adapter reset before continuing normal operation. Range: Min:0 Max:60 Default:10 linkup-delay=10; enable-npiv: Enables NPIV support in the driver. Requires SLI3 mode support in the adapter firmware. Range: Min:0 Max:1 Default:0 enable-npiv=0; vport-restrict-login: Restricts login to virtual ports to conserve resources. Requires SLI3 mode support in the adapter firmware. Requires enable-npiv parameter to be set to 1. Range: Min:0 Max:1 Default:1 vport-restrict-login=1; vport: Virtual port registration table. The enable-npiv must be set to 1. The vport table may have any number of comma delimited entries. Each entry must be of the form: "PHYS_WWPN:VPORT_WWNN:VPORT_WWPN:VPORT_ID" PHYS_WWPN = World Wide Port Name of adapter's physical port VPORT_WWNN = Desired World Wide Node Name of virtual port VPORT_WWPN = Desired World Wide Port Name of virtual port VPORT_ID = Desired virtual port id (1 to max vports) The port ids must start at 1 and increment by 1 with no gaps in the count. Example: vport=" c : c : c :1", " c : c : c :2", " c : c : c :1", " c : c : c :2", " c : c : c :3"; enable-auth: Enables DHCHAP support in the driver. Range: Min:0 Max:1 Default:0 enable-auth=0; max-xfer-size: Sets the maximum SCSI transfer size in bytes per IO This parameter is only used by the driver on i386 platforms. The driver does not limit transfer size on SPARC platforms. This parameter determines the scatter gather list buffer size. A pool of buffers is reallocated by the driver during boot. A larger transfer size requires a larger memory allocation. Memory_model max-xfer-size Small Medium Large Range: Min: Max: Default: max-xfer-size=339968; 28

29 Appendix A Management Table Template The following management table is required in "Chapter 3 Setting Up the Server" (page 9). Use it as required. A.1 WWN Instance Management Table for the Server WWN instance management table for the server Physical slot WWN Controller number Instance name name Physical path name 29

30 ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for Oracle Solaris Driver Settings for Sun Fibre Channel Cards Date of issuance: December 2010 Issuance responsibility: FUJITSU LIMITED The contents of this manual are liable to being updated without notice. While the contents of this manual are the product of all due care and diligence, no responsibility can be accepted for operational problems arising from any errors or missing information, or other use of the information contained in this manual. Fujitsu assumes no liability for damages to third party copyrights or other rights arising from the use of any information in this manual. Contents of this manual are not to be reproduced without permission from Fujitsu.

31

The Contents and Structure of this Manual. This document is composed of the following four chapters and an appendix.

The Contents and Structure of this Manual. This document is composed of the following four chapters and an appendix. Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000

More information

Server Support Matrix ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for Oracle Solaris

Server Support Matrix ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for Oracle Solaris Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000

More information

The Contents and Structure of this Manual. This document is composed of the following three chapters and an appendix.

The Contents and Structure of this Manual. This document is composed of the following three chapters and an appendix. Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000

More information

Server Support Matrix ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for Oracle Solaris

Server Support Matrix ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for Oracle Solaris Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000

More information

ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for VMware ESX

ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for VMware ESX Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000

More information

Server Support Matrix ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) ETERNUS Disk Storage System Settings

Server Support Matrix ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) ETERNUS Disk Storage System Settings Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000

More information

The Contents and Structure of this Manual. This document is composed of the following six chapters and an appendix.

The Contents and Structure of this Manual. This document is composed of the following six chapters and an appendix. Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000

More information

Server Support Matrix ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) ETERNUS Disk Storage System Settings

Server Support Matrix ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) ETERNUS Disk Storage System Settings Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000

More information

HP StorageWorks MPxIO for Sun Solaris application notes

HP StorageWorks MPxIO for Sun Solaris application notes HP StorageWorks MPxIO for Sun Solaris application notes Part number: AA-RW7CE-TE Third edition: December 2006 Legal and notice information Copyright 2005-2006 Hewlett-Packard Development Company, L.P.

More information

ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for VMware ESX

ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for VMware ESX Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000

More information

HP StorageWorks MPxIO for Sun Solaris application notes

HP StorageWorks MPxIO for Sun Solaris application notes HP StorageWorks MPxIO for Sun Solaris application notes Part number: AA-RW7CD-TE Third edition: August 2006 Legal and notice information Copyright 2005-2006 Hewlett-Packard Development Company, L.P. Hewlett-Packard

More information

The Contents and Structure of this Manual. This document is composed of the following three chapters.

The Contents and Structure of this Manual. This document is composed of the following three chapters. Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000

More information

ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for Linux

ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for Linux Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000

More information

ETERNUS Disk storage systems Server Connection Guide (FCoE) for Linux

ETERNUS Disk storage systems Server Connection Guide (FCoE) for Linux Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000

More information

ETERNUS Disk storage systems Server Connection Guide (FCoE) for Linux

ETERNUS Disk storage systems Server Connection Guide (FCoE) for Linux Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000

More information

The Contents and Structure of this Manual. This document is composed of the following 12 chapters.

The Contents and Structure of this Manual. This document is composed of the following 12 chapters. Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000

More information

ORACLE SOLARIS CLUSTER INTEROPERABILITY MATRIX

ORACLE SOLARIS CLUSTER INTEROPERABILITY MATRIX ORACLE SOLARIS CLUSTER INTEROPERABILITY MATRIX Fujitsu ETERNUS Storage Center Storage Supported ETERNUS DX100 S3, DX200 S3, DX200F, DX500 S3, DX600 S3, ETERNUS AF250, ETERNUS AF650, ETERNUS DX60, ETERNUS

More information

ETERNUS Disk storage systems Server Connection Guide (FCoE) for Linux

ETERNUS Disk storage systems Server Connection Guide (FCoE) for Linux Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000

More information

The Contents and Structure of this Manual. This document is composed of the following two chapters.

The Contents and Structure of this Manual. This document is composed of the following two chapters. Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000 model 700, 800, 900, 1100, 1200,

More information

The Contents and Structure of this Manual. This document is composed of the following two chapters.

The Contents and Structure of this Manual. This document is composed of the following two chapters. Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200 Disk storage system to a server running Solaris, HP-UX, Windows,

More information

ORACLE SOLARIS CLUSTER INTEROPERABILITY MATRIX

ORACLE SOLARIS CLUSTER INTEROPERABILITY MATRIX ORACLE SOLARIS CLUSTER INTEROPERABILITY MATRIX EMC VNX Family Unified Storage Storage Supported 2 (BLOCK) VNX5100, 5200, 5300, 5400, 5500, 5600, 5700, 5800, 7500, 7600, 8000, F5000, F7000 VNXe1600, 3100,

More information

The Contents and Structure of this Manual. This document is composed of the following six chapters and three appendices.

The Contents and Structure of this Manual. This document is composed of the following six chapters and three appendices. Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000

More information

The Contents and Structure of this Manual. This document is composed of the following 12 chapters.

The Contents and Structure of this Manual. This document is composed of the following 12 chapters. Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000

More information

ORACLE SOLARIS CLUSTER INTEROPERABILITY MATRIX

ORACLE SOLARIS CLUSTER INTEROPERABILITY MATRIX ORACLE SOLARIS CLUSTER INTEROPERABILITY MATRIX NetApp Enterprise Storage Systems (Fibre Channel and iscsi) FAS Series (FC/iSCSI): 250, 270, 2020, 2040, 2050, 2220, 2240-2, 2240-4, 2520, 2552, 2554, 3020,

More information

HP StorageWorks 4000/6000/8000 Enterprise Virtual Array connectivity for Sun Solaris installation and reference guide

HP StorageWorks 4000/6000/8000 Enterprise Virtual Array connectivity for Sun Solaris installation and reference guide HP StorageWorks 4000/6000/8000 Enterprise Virtual Array connectivity for Sun Solaris installation and reference guide Part number: 5697-5263 First edition: May 2005 Legal and notice information Copyright

More information

EMC Fibre Channel with Emulex Host Bus Adapters in the Solaris Environment

EMC Fibre Channel with Emulex Host Bus Adapters in the Solaris Environment EMC Fibre Channel with Emulex Host Bus Adapters in the Solaris Environment P/N 300-001-156 REV A11 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com Copyright

More information

The Contents and Structure of this Manual. This document is composed of the following ten chapters.

The Contents and Structure of this Manual. This document is composed of the following ten chapters. Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000

More information

Configuration Guide -Server Connection-

Configuration Guide -Server Connection- FUJITSU Storage ETERNUS DX, ETERNUS AF Configuration Guide -Server Connection- (Fibre Channel) for Citrix XenServer This page is intentionally left blank. Preface This manual briefly explains the operations

More information

INSTALLATION GUIDE. FUJITSU PCI Fibre Channel 4.0 Update2

INSTALLATION GUIDE. FUJITSU PCI Fibre Channel 4.0 Update2 Manual code: C120-E392-03EN INSTALLATION GUIDE FUJITSU PCI Fibre Channel 4.0 Update2 for Solaris Operating System The Customer acknowledges and agrees that the Product is designed, developed and manufactured

More information

Overview. Implementing Fibre Channel SAN Boot with the Oracle ZFS Storage Appliance. January 2014 By Tom Hanvey; update by Peter Brouwer Version: 2.

Overview. Implementing Fibre Channel SAN Boot with the Oracle ZFS Storage Appliance. January 2014 By Tom Hanvey; update by Peter Brouwer Version: 2. Implementing Fibre Channel SAN Boot with the Oracle ZFS Storage Appliance January 2014 By Tom Hanvey; update by Peter Brouwer Version: 2.0 This paper describes how to implement a Fibre Channel (FC) SAN

More information

The HBAs tested in this report are the Brocade 825 and the Emulex LightPulse LPe12002 and LPe12000.

The HBAs tested in this report are the Brocade 825 and the Emulex LightPulse LPe12002 and LPe12000. HBA Product Evaluation Evaluation report prepared under contract with Corporation Introduction Due to increased interest in 8 Gb/s Fibre Channel host bus adapters, Corporation commissioned Demartek to

More information

Overview. Implementing Fibre Channel SAN Boot with Oracle's Sun ZFS Storage Appliance. August By Tom Hanvey; update by Peter Brouwer

Overview. Implementing Fibre Channel SAN Boot with Oracle's Sun ZFS Storage Appliance. August By Tom Hanvey; update by Peter Brouwer Implementing Fibre Channel SAN Boot with Oracle's Sun ZFS Storage Appliance August 2012 By Tom Hanvey; update by Peter Brouwer This paper describes how to implement a Fibre Channel (FC) SAN boot solution

More information

Best Practices Guide: Emulex Virtual HBA Solutions and VMware ESX Server 3.5

Best Practices Guide: Emulex Virtual HBA Solutions and VMware ESX Server 3.5 Best Practices Guide: Emulex Virtual HBA Solutions and VMware ESX Server 3.5 How to deploy VMware ESX Server 3.5 on a Fibre Channel Using Emulex Virtual HBA Technology Introduction IT organizations are

More information

Dell Compellent Volume Expansion with Solaris 10 UFS. Technical Tip

Dell Compellent Volume Expansion with Solaris 10 UFS. Technical Tip Dell Compellent Volume Expansion with Solaris 10 UFS Technical Tip Page 2 Document revision Date Revision Comments 8/30/2011 A Initial Draft 10/14/2011 B Fixed Some Typos THIS TECHNICAL TIP IS FOR INFORMATIONAL

More information

The Contents and Structure of this Manual. This document is composed of the following four chapters.

The Contents and Structure of this Manual. This document is composed of the following four chapters. Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000

More information

FUJITSU Storage ETERNUS DX, ETERNUS AF Configuration Guide -Server Connection-

FUJITSU Storage ETERNUS DX, ETERNUS AF Configuration Guide -Server Connection- FUJITSU Storage ETERNUS DX, ETERNUS AF Configuration Guide -Server Connection- (iscsi) ETERNUS DX S4/S3 series Hybrid Storage Systems, ETERNUS AF series, ETERNUS DX200F All-Flash Arrays Settings This page

More information

FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection-

FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection- FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection- (SAS) for VMware ESX This page is intentionally left blank. Preface This manual briefly explains the operations that need to be performed

More information

ORACLE SOLARIS CLUSTER INTEROPERABILITY MATRIX

ORACLE SOLARIS CLUSTER INTEROPERABILITY MATRIX ORACLE SOLARIS CLUSTER INTEROPERABILITY MATRIX EMC Symmetrix Storage Supported 3,15 Symmetrix DMX-2 6, DMX-3, DMX-4 Symmetrix 8000, Symmetrix VMAX 11, VMAXe 11, VMAX 10K 11 (SN XXX959XXXX / SN XXX987XXXX)

More information

Disk Replacement. Introduction CHAPTER

Disk Replacement. Introduction CHAPTER CHAPTER 17 Revised: July 2010, Introduction This chapter describes the process of replacing a defective Cisco BTS 10200 Softswitch disk. Each Cisco BTS 10200 system element contains two hard disks (disk

More information

Configuration Guide -Server Connection-

Configuration Guide -Server Connection- FUJITSU Storage ETERNUS DX, ETERNUS AF Configuration Guide -Server Connection- (Fibre Channel) for VMware ESX This page is intentionally left blank. Preface This manual briefly explains the operations

More information

Configuration Guide -Server Connection-

Configuration Guide -Server Connection- FUJITSU Storage ETERNUS DX, ETERNUS AF Configuration Guide -Server Connection- (Fibre Channel) for Windows This page is intentionally left blank. Preface This manual briefly explains the operations that

More information

Configuration Guide -Server Connection-

Configuration Guide -Server Connection- FUJITSU Storage ETERNUS DX, ETERNUS AF Configuration Guide -Server Connection- (Fibre Channel) for Windows This page is intentionally left blank. Preface This manual briefly explains the operations that

More information

Qualified Hardware Components

Qualified Hardware Components For DataCore and Host Servers October 2018 This guide lists all hardware components that are considered qualified by DataCore Software for use with SANsymphony. The authority on real-time data Changes

More information

EMC Fibre Channel with QLogic Host Bus Adapters in the Solaris Environment

EMC Fibre Channel with QLogic Host Bus Adapters in the Solaris Environment EMC Fibre Channel with QLogic Host Bus Adapters in the Solaris Environment P/N 300-001-163 REV A01 SEPTEMBER 2003 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508 -435-1000 www.emc.com

More information

ETERNUS Multipath Driver (Oracle Solaris Version) Installation Information

ETERNUS Multipath Driver (Oracle Solaris Version) Installation Information ETERNUS Multipath Driver (Oracle Solaris Version) Installation Information September 2011 Contents Supported OS 1 Restrictions and Resolution schedule (the driver for Solaris 10 OS and Solaris 9 OS) 1

More information

Fibre Channel QLA Driver for Solaris SPARC and x86 Platforms. Table of Contents

Fibre Channel QLA Driver for Solaris SPARC and x86 Platforms. Table of Contents Fibre Channel QLA Driver for Solaris SPARC and x86 Platforms This software license applies only to QLogic customers. QLogic Corporation. All rights reserved. Table of Contents 1. OS Support 2. Software

More information

Power Systems SAN Multipath Configuration Using NPIV v1.2

Power Systems SAN Multipath Configuration Using NPIV v1.2 v1.2 Bejoy C Alias IBM India Software Lab Revision History Date of this revision: 27-Jan-2011 Date of next revision : TBD Revision Number Revision Date Summary of Changes Changes marked V1.0 23-Sep-2010

More information

Tunables for the Sun StorEdge TM SAN Foundation Suite: Optimizing for Performance and Failover

Tunables for the Sun StorEdge TM SAN Foundation Suite: Optimizing for Performance and Failover Tunables for the Sun StorEdge TM SAN Foundation Suite: Optimizing for Performance and Failover Chris Wood, Sajid Zia, and Dennis Kleppen June 2007 Sun Microsystems, Inc. Abstract: This article describes

More information

NetBackup SAN Client and Fibre Transport Troubleshooting Guide. 2 What are the components of the SAN Client feature?

NetBackup SAN Client and Fibre Transport Troubleshooting Guide. 2 What are the components of the SAN Client feature? Symantec TechNote 288437 NetBackup SAN Client and Fibre Transport Troubleshooting Guide 1 Introduction Revision F This document explains how to troubleshoot different failures that may occur while using

More information

Interoperability of Bloombase StoreSafe Security Server, QLogic FC-HBAs and QLogic SAN Switch for Transparent Storage Area Network (SAN) Encryption

Interoperability of Bloombase StoreSafe Security Server, QLogic FC-HBAs and QLogic SAN Switch for Transparent Storage Area Network (SAN) Encryption Bloombase Interoperability Program P1 2012 Bloombase Interoperability of Bloombase StoreSafe Security Server, QLogic FC-HBAs and QLogic SAN Switch for Transparent Storage Area Network (SAN) Encryption

More information

The DataCore and Host servers

The DataCore and Host servers The DataCore and Host servers Qualified Hardware Components February 2018 This guide lists all hardware components that are considered qualified by DataCore Software for use with SANsymphony. In general

More information

Qualified Hardware Components

Qualified Hardware Components DataCore and Host Servers November 2018 This guide lists all hardware components that are considered qualified by DataCore Software for use with SANsymphony. Also see Minimum Hardware Requirements https://www.datacore.com/products/software-defined-storage/tech/prerequisites/

More information

Building a High Availability System on Fujitsu SPARC M12 and Fujitsu M10/SPARC M10 Servers (Overview)

Building a High Availability System on Fujitsu SPARC M12 and Fujitsu M10/SPARC M10 Servers (Overview) Building a High Availability System on Fujitsu SPARC M12 and Fujitsu M10/SPARC M10 Servers (Overview) September 2017 Rev 3.0 Fujitsu LIMITED Contents Introduction 1. Model Case of HA System 2. Example

More information

The DataCore and Host servers

The DataCore and Host servers The DataCore and Host servers Qualified Hardware Components May 2018 This guide lists all hardware components that are considered qualified by DataCore Software for use with SANsymphony. In general DataCore

More information

Note: The arrays supported now include the VSP F700, F900, G700, G900, F350, F370, G350, and G370.

Note: The arrays supported now include the VSP F700, F900, G700, G900, F350, F370, G350, and G370. Solaris Support Matrix Hitachi VSP G1x00, F1500, Gxx0, Fxx0, VSP, HUS VM Note: Configurations added since the last matrix will be shown in red text. Introduction Use this interoperability matrix to check

More information

FUJITSU Storage ETERNUS Multipath Driver 2 (for AIX) Installation Information

FUJITSU Storage ETERNUS Multipath Driver 2 (for AIX) Installation Information FUJITSU Storage ETERNUS Multipath Driver 2 (for AIX) Installation Information Oct 2016 Contents Contents... 1 Supported Operating System (OS) Versions... 1 Supported Disk Storage Systems... 1 Connection

More information

VMware Infrastructure Update 1 for Dell PowerEdge Systems. Deployment Guide. support.dell.com

VMware Infrastructure Update 1 for Dell PowerEdge Systems. Deployment Guide.   support.dell.com VMware Infrastructure 3.0.2 Update 1 for Dell PowerEdge Systems Deployment Guide www.dell.com support.dell.com Notes and Notices NOTE: A NOTE indicates important information that helps you make better

More information

Emulex LPFC Driver for Solaris. Version 6.11c User Manual

Emulex LPFC Driver for Solaris. Version 6.11c User Manual Emulex LPFC Driver for Solaris Version 6.11c User Manual Copyright 2007 Emulex Corporation. All rights reserved worldwide. No part of this document may be reproduced by any means nor translated to any

More information

Exam : S Title : Snia Storage Network Management/Administration. Version : Demo

Exam : S Title : Snia Storage Network Management/Administration. Version : Demo Exam : S10-200 Title : Snia Storage Network Management/Administration Version : Demo 1. A SAN architect is asked to implement an infrastructure for a production and a test environment using Fibre Channel

More information

Note: The arrays supported now include the VSP F700, F900, G700, G900, F350, F370, G350, and G370.

Note: The arrays supported now include the VSP F700, F900, G700, G900, F350, F370, G350, and G370. Solaris Support Matrix Hitachi VSP G1x00, F1500, Gxx0, Fxx0, VSP, HUS VM Note: Configurations added since the last matrix will be shown in red text. Introduction Use this interoperability matrix to check

More information

This page is intentionally left blank.

This page is intentionally left blank. This page is intentionally left blank. Preface This ETERNUS Multipath Driver User's Guide describes the features, functions, and operation of the "ETERNUS Multipath Driver" (hereafter referred to as "Multipath

More information

ETERNUS Veritas Operations Manager Storage Insight Plug-in 1.0 User s Guide P2X ENZ0

ETERNUS Veritas Operations Manager Storage Insight Plug-in 1.0 User s Guide P2X ENZ0 ETERNUS Veritas Operations Manager Storage Insight Plug-in 1.0 User s Guide This page is intentionally left blank. Preface This manual explains how to use and operate the ETERNUS Veritas Operations Manager

More information

SUN STORAGETEK DUAL 8 Gb FIBRE CHANNEL DUAL GbE EXPRESSMODULE HOST BUS ADAPTER

SUN STORAGETEK DUAL 8 Gb FIBRE CHANNEL DUAL GbE EXPRESSMODULE HOST BUS ADAPTER SUN STORAGETEK DUAL 8 Gb FIBRE CHANNEL DUAL GbE EXPRESSMODULE HOST BUS ADAPTER KEY FEATURES MULTIPROTOCOL NETWORK HOST BUS ADAPTER FOR SUN BLADE SERVERS Comprehensive virtualization capabilities with support

More information

Hardware Installation Guide for the QLA22xx Board Family. Fibre Channel Host Adapter Boards for the PCI Bus

Hardware Installation Guide for the QLA22xx Board Family. Fibre Channel Host Adapter Boards for the PCI Bus Hardware Installation Guide for the QLA22xx Board Family Fibre Channel Host Adapter Boards for the PCI Bus FC0151103-00 E February 6, 2001 QLogic Corporation Information furnished in this manual is believed

More information

Symmetrix Fibre Channel with Qlogic Host Bus Adapters in the SCO UnixWare 7 Environment

Symmetrix Fibre Channel with Qlogic Host Bus Adapters in the SCO UnixWare 7 Environment Symmetrix Fibre Channel with Qlogic Host Bus Adapters in the SCO UnixWare 7 Environment November 2000 Copyright 2000 EMC Corporation. All rights reserved. No part of this publication may be reproduced

More information

FC-FCoE Adapter Inbox Driver Update for Linux Kernel 2.6.x. Table of Contents

FC-FCoE Adapter Inbox Driver Update for Linux Kernel 2.6.x. Table of Contents FC-FCoE Adapter Inbox Driver Update for Linux Kernel 2.6.x QLogic Corporation. All rights reserved. Table of Contents 1. Version 2. Changes 3. Bug Fixes 4. Known Issues 5. Additional Information 6. History

More information

Interoperability of Bloombase StoreSafe and Huawei OceanStor T-Series for Transparent Storage Encryption

Interoperability of Bloombase StoreSafe and Huawei OceanStor T-Series for Transparent Storage Encryption Bloombase Interoperability Program P1 2014 Bloombase Interoperability of Bloombase StoreSafe and Huawei OceanStor T-Series for Transparent Storage Encryption October, 2014 Executive Summary Huawei's new-generation

More information

Building a High Availability System on Fujitsu SPARC M12 and Fujitsu M10/SPARC M10 Servers (Overview)

Building a High Availability System on Fujitsu SPARC M12 and Fujitsu M10/SPARC M10 Servers (Overview) Building a High Availability System on Fujitsu SPARC M12 and Fujitsu M10/SPARC M10 Servers (Overview) May. 2017 Rev 2.1 Fujitsu LIMITED Contents Introduction 1. Model Case of HA System 2. Example of HA

More information

Release Notes P/N REV A03 January 3, 2006

Release Notes P/N REV A03 January 3, 2006 Sun StorEdge Traffic Manager for CLARiiON Release Notes P/N 300-002-978 REV A03 January 3, 2006 These release notes contain supplemental information about Sun StorEdge Traffic Manager for CLARiiON storage

More information

FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection-

FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection- FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection- (SAS) for Citrix XenServer This page is intentionally left blank. Preface This manual briefly explains the operations that need to be

More information

Setup for Microsoft Cluster Service Update 1 Release for ESX Server 3.5, ESX Server 3i version 3.5, VirtualCenter 2.5

Setup for Microsoft Cluster Service Update 1 Release for ESX Server 3.5, ESX Server 3i version 3.5, VirtualCenter 2.5 Setup for Microsoft Cluster Service Update 1 Release for ESX Server 3.5, ESX Server 3i version 3.5, VirtualCenter 2.5 Setup for Microsoft Cluster Service Setup for Microsoft Cluster Service Revision: 041108

More information

Oracle Enterprise Manager Ops Center. Introduction. What You Will Need. Configure and Install Root Domains 12c Release 3 (

Oracle Enterprise Manager Ops Center. Introduction. What You Will Need. Configure and Install Root Domains 12c Release 3 ( Oracle Enterprise Manager Ops Center Configure and Install Root Domains 12c Release 3 (12.3.0.0.0) E60040-01 June 2015 This guide provides an end-to-end example for how to use Oracle Enterprise Manager

More information

Emulex Drivers for Windows for LightPulse Adapters. User Guide Release 12.0

Emulex Drivers for Windows for LightPulse Adapters. User Guide Release 12.0 Emulex Drivers for Windows for LightPulse Adapters User Guide Release 12.0 July 5. 2018 , the pulse logo, Connecting everything, Avago Technologies, Avago, and the A logo are among the trademarks of and/or

More information

Oracle VM. Getting Started Guide for Release 3.2

Oracle VM. Getting Started Guide for Release 3.2 Oracle VM Getting Started Guide for Release 3.2 E35331-04 March 2014 Oracle VM: Getting Started Guide for Release 3.2 Copyright 2011, 2014, Oracle and/or its affiliates. All rights reserved. Oracle and

More information

Fibre Channel card Users Guide

Fibre Channel card Users Guide C122-E012-19EN PRIMEQUEST Fibre Channel card Users Guide 2G Fibre Channel PCI-X card (MC-08FC11/ MC-08FC71) 4G Fibre Channel PCI-X card (MC-08FC31/ MC-08FC41) 4G Fibre Channel PCI-express card (MC-08FC51/

More information

Emulex Driver for VMware ESX 4.x. Version vmw User Manual. One Network. One Company.

Emulex Driver for VMware ESX 4.x. Version vmw User Manual. One Network. One Company. Emulex Driver for VMware ESX 4.x Version 8.2.0.30.53vmw User Manual P004736-01A Rev. A One Network. One Company. Connect with Emulex. Copyright 2003-2009 Emulex. All rights reserved worldwide. No part

More information

Emulex Driver for VMware ESX 4.x. Version vmw User Manual. One Network. One Company.

Emulex Driver for VMware ESX 4.x. Version vmw User Manual. One Network. One Company. Emulex Driver for VMware ESX 4.x Version 8.2.0.30.52vmw User Manual P004664-01A Rev. A One Network. One Company. Connect with Emulex. Copyright 2003-2009 Emulex. All rights reserved worldwide. No part

More information

Emulex -branded Fibre Channel HBA Product Line

Emulex -branded Fibre Channel HBA Product Line Emulex -branded Fibre Channel HBA Product Line Emulex-branded Fibre Channel (FC) Host Bus Adapters (HBAs) by Broadcom are designed to address the demanding performance, reliability and management requirements

More information

Emulex LPe16000B Gen 5 Fibre Channel HBA Feature Comparison

Emulex LPe16000B Gen 5 Fibre Channel HBA Feature Comparison Demartek Emulex LPe16000B Gen 5 Fibre Channel HBA Feature Comparison Evaluation report prepared under contract with Emulex Executive Summary Explosive growth in the complexity and amount of data of today

More information

Mac OS X Fibre Channel connectivity to the HP StorageWorks Enterprise Virtual Array storage system configuration guide

Mac OS X Fibre Channel connectivity to the HP StorageWorks Enterprise Virtual Array storage system configuration guide Mac OS X Fibre Channel connectivity to the HP StorageWorks Enterprise Virtual Array storage system configuration guide Part number: 5697-0025 Third edition: July 2009 Legal and notice information Copyright

More information

FUJITSU Storage ETERNUS AF series and ETERNUS DX S4/S3 series Non-Stop Storage Reference Architecture Configuration Guide

FUJITSU Storage ETERNUS AF series and ETERNUS DX S4/S3 series Non-Stop Storage Reference Architecture Configuration Guide FUJITSU Storage ETERNUS AF series and ETERNUS DX S4/S3 series Non-Stop Storage Reference Architecture Configuration Guide Non-stop storage is a high-availability solution that combines ETERNUS SF products

More information

An Oracle Deployment Guide September Deploying a Converged Network Using Oracle CNAs and a Cisco FCoE Switch

An Oracle Deployment Guide September Deploying a Converged Network Using Oracle CNAs and a Cisco FCoE Switch An Oracle Deployment Guide September 2011 Deploying a Converged Network Using Oracle CNAs and a Cisco FCoE Switch Deploying a Converged Network Using Oracle CNAs and a Cisco FCoE Switch Disclaimer Information

More information

Enhanced Support Facility User s Guide For Dynamic Reconfiguration (PRIMEPOWER)

Enhanced Support Facility User s Guide For Dynamic Reconfiguration (PRIMEPOWER) C120-E115-09ENZ2(A) Enhanced Support Facility User s Guide For Dynamic Reconfiguration (PRIMEPOWER) Preface Preface Purpose This manual provides an overview of each of the functions of the Dynamic Reconfiguration

More information

SAN Configuration Guide

SAN Configuration Guide ONTAP 9 SAN Configuration Guide November 2017 215-11168_G0 doccomments@netapp.com Updated for ONTAP 9.3 Table of Contents 3 Contents Considerations for iscsi configurations... 5 Ways to configure iscsi

More information

Emulex Drivers for Linux for LightPulse Adapters Release Notes

Emulex Drivers for Linux for LightPulse Adapters Release Notes Emulex Drivers for Linux for LightPulse Adapters Release Notes Versions: FC Version 11.4.142.21 Date: September 6, 2017 Purpose and Contact Information These release notes describe the new features, current

More information

EMC Fibre Channel with QLogic Host Bus Adapters in the NetWare Environment

EMC Fibre Channel with QLogic Host Bus Adapters in the NetWare Environment EMC Fibre Channel with QLogic Host Bus Adapters in the NetWare Environment P/N 300-001-162 REV A03 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508 -435-1000 www.emc.com Copyright

More information

2014 LENOVO INTERNAL. ALL RIGHTS RESERVED.

2014 LENOVO INTERNAL. ALL RIGHTS RESERVED. 2014 LENOVO INTERNAL. ALL RIGHTS RESERVED. Connectivity Categories and Selection Considerations NIC HBA CNA Primary Purpose Basic Ethernet Connectivity Connection to SAN/DAS Converged Network and SAN connectivity

More information

QLogic QLx2xx/QLA22xx/QLx23xx/QLx24xx Fibre Channel Linux Driver for Kernel 2.4. Table of Contents

QLogic QLx2xx/QLA22xx/QLx23xx/QLx24xx Fibre Channel Linux Driver for Kernel 2.4. Table of Contents QLogic QLx2xx/QLA22xx/QLx23xx/QLx24xx Fibre Channel Linux Driver for Kernel 2.4 Version: 7.07.05 OS Support : HBA Support: Red Hat RHEL 3 AS - Update 7 and Update 6 (IA32, EM64T, AMD64, IA64) Novell SLES

More information

Sun SPARC Enterprise M9000 Server with Oracle Database 11g Release 2

Sun SPARC Enterprise M9000 Server with Oracle Database 11g Release 2 Sun SPARC Enterprise M9000 Server with Oracle Database 11g Release 2 TPC-H 2.11.0 TPC-Pricing 1.5.0 Report Date:October 5, 2010 First Revision: December 9, 2010 Second Revision: September 14, 2011 Total

More information

SANsurfer Fibre Channel Command Line Interface (CLI) Table of Contents

SANsurfer Fibre Channel Command Line Interface (CLI) Table of Contents SANsurfer Fibre Channel Command Line Interface (CLI) QLogic Corporation All rights reserved Table of Contents 1 Package Contents 2 Requirements 2.1 Hardware Requirements 2.2 Software Requirements 3 OS

More information

x10sure 3.2 One to one recover after repair

x10sure 3.2 One to one recover after repair x10sure 3.2 One to one recover after repair 1 1:1 WITH EXTERNAL STORAGE 2 1.1 After power failure etc. 2 1.2 After repair 2 1.3 After replacement of the failed node 3 1.3.1 Boot device via FC 3 1.3.2 Boot

More information

Surveillance Dell EMC Storage with FLIR Latitude

Surveillance Dell EMC Storage with FLIR Latitude Surveillance Dell EMC Storage with FLIR Latitude Configuration Guide H15106 REV 1.1 Copyright 2016-2017 Dell Inc. or its subsidiaries. All rights reserved. Published June 2016 Dell believes the information

More information

SANsurfer FC/CNA HBA Command Line Interface (CLI) Table of Contents

SANsurfer FC/CNA HBA Command Line Interface (CLI) Table of Contents SANsurfer FC/CNA HBA Command Line Interface (CLI) QLogic Corporation. All rights reserved. Table of Contents 1. Package Contents 2. Requirements 2.1 Hardware Requirements 2.2 Software Requirements 3. OS

More information

ETERNUS VAAI Plug-in for VMware vsphere User s Guide

ETERNUS VAAI Plug-in for VMware vsphere User s Guide ETERNUS VAAI Plug-in for VMware vsphere5 1.0.0 User s Guide Preface This document provides an overview of ETERNUS VAAI Plug-in for VMware vsphere5 and discribes how to use it. The Structure of this Document

More information

S SNIA Storage Networking Management & Administration

S SNIA Storage Networking Management & Administration S10 201 SNIA Storage Networking Management & Administration Version 23.3 Topic 1, Volume A QUESTION NO: 1 Which two (2) are advantages of ISL over subscription? (Choose two.) A. efficient ISL bandwidth

More information

Technical Brief: How to Configure NPIV on VMware vsphere 4.0

Technical Brief: How to Configure NPIV on VMware vsphere 4.0 Technical Brief: How to Configure NPIV on VMware vsphere 4.0 Provides step-by-step instructions on how to configure NPIV on VMware vsphere 4.0 in a Brocade fabric. Leveraging NPIV gives the administrator

More information

Configuration Guide for HP OpenVMS Host Attachment Hitachi Virtual Storage Platform Hitachi Universal Storage Platform V/VM

Configuration Guide for HP OpenVMS Host Attachment Hitachi Virtual Storage Platform Hitachi Universal Storage Platform V/VM Configuration Guide for HP OpenVMS Host Attachment Hitachi Virtual Storage Platform Hitachi Universal Storage Platform V/VM FASTFIND LINKS Document Organization Product Version Getting Help Contents MK-96RD653-05

More information

Emulex Drivers Version 10.0 for VMware ESXi

Emulex Drivers Version 10.0 for VMware ESXi Emulex Drivers Version 10.0 for VMware ESXi User Manual Emulex Connects Servers, Storage and People 2 EMULEX CONFIDENTIAL. Copyright 2003 2013 Emulex. All rights reserved worldwide. No part of this document

More information

HP 3PAR Management Console

HP 3PAR Management Console HP 3PAR Management Console User Guide Abstract The HP 3PAR Management Console and the topics in this Help system are for use by system and storage administrators who monitor and direct system configurations

More information

Sun Dual Port 10GbE SFP+ PCIe 2.0 Networking Cards with Intel GbE Controller

Sun Dual Port 10GbE SFP+ PCIe 2.0 Networking Cards with Intel GbE Controller Sun Dual Port 10GbE SFP+ PCIe 2.0 Networking Cards with Intel 82599 10GbE Controller Oracle's Sun Dual Port 10 GbE PCIe 2.0 Networking Cards with SFP+ pluggable transceivers, which incorporate the Intel

More information