SETTING FOR ZEMIC DIGITAL LOAD CELL INDICATOR
|
|
- Wesley Richards
- 6 years ago
- Views:
Transcription
1 Feature: - SETTING FOR ZEMIC DIGITAL LOAD CELL INDICATOR 1. High bright 1 red display. 2. No need of calibration. 3. No corner adjustment. 4. High accuracy up to eight load cell. 5. Moisture proof operation. 6. Can operate in 1kg, 2kg, 5kg, 10kg, 20kg and 50kg accuracy. 7. Auto zero tracking. 8. Can do manual calibration. 9. Can do individual load cell corner adjustment from indicator. No need of preset or resistance 10. Single indicator for Zemic load cell. 11. Serial communication for computer and IT interface. Now we start the function of the indicator This indicator is very simple in use. There are four keys of front panel 1. Z/t this key is zero tare key and further we will call it as key1. 2. this key is shift key and we will call it as key2. 3. this key is up key and we will call it as key3. 4. Func this is function key and we will call it as key4. Now we start the function of the indicator In digital load cell we have to give a unique number to every load cell and it will be done by the indicator as follows 1. Connect single load cell with the indicator as per connection diagram and switch on the indicator while pressing any key. 2. Display shows C MODE and then Press key 3 to make C 0000 to C Press key 1 and display shows type. 5. Press key 3 to enter type of load cell 0 for zemic and 1 for hak 6. Press key 1 and exit.
2 Switch on the indicator while pressing any key. 1. Display shows C MODE and then Press key3 to make C 0000 to c Press key1 and display will show the type you enter 4. Press key1 and display shows tlc Here press key3 to enter total number of load cell. 6. Press key1 and display shows lc set and indicator goes to setting mode. 7. Press key1 again display shows lc 1. This shows that the loadcell connected will be marked as load cell number Now press key1 and display shows wait. Here wait till the display turns to ok lc1.if there is an error then display will shows error on screen and will go to check the load cell again. 9. Again press key1 and display shows lc 2. Hear disconnect first load cell and mark it as loadcell 1 and connect second load cell and repeat the same process till all load cell get the numbers. 10. Here we end the load cell marking Now connect all load cell and switch on the machine. If there come 0 on screen then machine is working properly. Otherwise machine will shows the load cell number which is faulty or wire of this load cell is not connected properly. Then check that load cell and proceed. Capacity setting: Press any key and switch on the machine. Here enter password And press key1. Display shows enter again press kay1, Display shows ma cap press key1 and then enter desire capacity for 60 ton. Press key1 display shows deci here enter decimal point. Press key1 display shows res.here enter accuracy say 05 for 5 kg and 10 for 10kg Press key1 display shows A-0. This is auto zero tracking and this value multiply by accuracy will be auto zeroed. Press key1 display shows stab. This is for air locking or for drifting and if we increase this value then stability increase but the weight will slow. Press key1 display shows cali. Here you decide either you want to calibrate the scale or not.
3 0 = no calibration and no corner adjustment. 1 = only calibration and no corner adjustement 2 = both calibration and corner adjustment can be done Press key1 and exit. Calibration:- These load cells are pre calibrated and need not to calibrate the system. For this you have to put 0 in cali parameter as described above. If calib parameter is 0 then no calibration and corner adjustment can be done. If you want only calibration then put 1 in this parameter. If you want both cornors adjustement and calibration then put 2 in this parameter. For calibration press any key and switch on the machine Here enter passward And press key1. Display shows means all calibration can be done with respect to kg. Press key1 and display shows here you can enter the weight you want with respect to kg Example1: Suppose the weighbridge is showing kg for kg weight then formula will be 29925/30525*10000 = 9803 kg. So we have to put 9803 kg. Example2: Suppose the weighbridge is showing kg for kg weight then formula will be 28725/25135*10000 = kg. So we have to put kg. Here press key1 after entering the weight and calibration is done. For corner adjustment press any key and switch on the machine Here enter password And press key1. Press key1 and display shows corner
4 Press key1. Display shows means all corner adjustment can be done with respect to kg. Press key1 and display shows LC-1 here you can enter correction in weight of load cell no. 1 by simply + or - with key 2 and key 3 with respect to kg. Press key1 and display shows LC-2 here you can enter correction in weight of load cell no. 2 by simply + or - with key 2 and key 3 with respect to kg. Ex. If you want to increase weight of LC1 by 10 kg then put 10 in LC1 value and if you want to decrease the weight in LC1 by 10 kg then put -10 in LC1. This procedure goes up to the TLC(TOTAL NUMBER OF LOAD CELL) value. Example3: Suppose the lc-1 is showing kg for kg weight then formula will be 20200/20000*10000 = kg. So we have to put 100 kg( ) in lc-1. Example4: Suppose the lc-2 of weighbridge is showing kg for kg weight then formula will be 15575/15625*10000 = 9968 kg. So we have to put -32 kg ( ) in lc-2. Example5: Suppose the lc-3 weighbridge is showing 20 kg less weight for kg then formula will be ( )/15355*10000 = kg. So we have to put 13 kg in lc-3. If you don t need to adjust other load cell then put for no corner adjustment. If you again want the scale without calibration then again put 0 in parameter cali. That s all..
5 For checking zemic load cell please check resistance as follows:- 1. Black and brown = 9k to 11k. 2. Black and white = 9k to 11 k. 3. Black and yellow = 9k to 11k. 4. Black and blue = 9k to 11k. Connection diagram for zemic 6 wire load cell: Connect loadcell wire on 15 pin connector as below Pin no. 1 and 2.red Pin no. 3..brown Pin no. 4..yellow Pin no. 5..white Pin no. 6..blue Pin no. 7 and 8..black These colour combination is for zemic six wire loadcell as per zemic load cell color code. Connect computer to 9 pin d type connector as follows. Pin no 2 Pin no 5 data out goes to pin no 2 of 9 pin computer connector. ground goes to pin no 5 of 9 pin computer connecter.
Model No Load Indicator with Relay Output & Double Calibration Point Manual
Embedded System Laboratories Pvt. Ltd. (An ISO 9001:2008 certified company) Model No.-0501-5002 Load Indicator with Relay Output & Double Calibration Point Manual 86, Lane No. 7, Near Laxmi Dairy, Gurudwara
More informationi ysin i dia i.c. om o
www.isysindia.com Weigh Bridge PCB Configuration & Calibration Manual To configure the machine, connect the power supply. Short the jumper pins as shown in the above circuit provided for hardware lock.
More informationCảm ơn các bạn đã tham khảo tài liệu cân điện tử từ CÂN ĐIỆN TỬ GIA PHÁT!
Đ/c1: 534 Điện Biên Phủ, Phường 21, Quận Bình Thạnh, Tp Hồ Chí Minh Đ/c2: 42 Hùng Vương, Phường Xuân Bình, Thị xã Long Khánh, Tỉnh Đồng Nai Website: www.cangiaphat.com Email: giaphat.scale@gmail.com Zalo,
More informationi ysin i dia i.c. om o
www.isysindia.com R5.0V1 PCB Configuration & Calibration Manual To configure the machine, connect the power supply. Now press TARE key(k4) and with the TARE key(k4) pressed power on the Machine (switch
More informationM260 Load Cell Amplifiers
E L 4 - + 2-3 1-2 M260 Load Cell Amplifiers Description. This fast start guide shows basic installation, setup, and calibration for most applications. For more specific information contact Minsterport.
More informationSCS3MT080, SCS3MT100, SCS3MT120, SHDHS1500 & SPLS1000 User Manual
www.scintex.com.au sales@scintex.com.au SCS3MT080, SCS3MT100, SCS3MT120, SHDHS1500 & SPLS1000 User Manual Technical Data Working Temperature:-5 to 35 C Storage Temperature:-25 to 50 C Stainless Steel Casing:
More informationINDUSTRIAL INSTRUMENTATION
INDUSTRIAL INSTRUMENTATION Table of contents. Table of contents.... 2 Explanation of production screen.... 3 Wiring connection for Flex-CK model Flex.... 4 Wiring connection for Flex-CK model Flex-2100...
More informationKW serial. User s guide. Bench Scales UGKW-E0302
KW serial Bench Scales User s guide UGKW-E0302 KW serial bench scale user s manual Table of Contents SECTION 1 INTRODUCTION 1 SECTION 2 SPECIFICATIONS.. 2 SECTION 3 INSTALLATION.3 SECTION 4 KEY DESCRIPTIONS
More informationChennai Weighing System
Chennai Weighing System No:27/1, New Boag Road, T.Nagar,Chennai- 600017 Cell:98400 29989, Ph:044-2432 0078 E-mail:chennai_weighing@yahoo.co.in Contact Person: D.Dayabaran CWS CONTENTS : Product Information
More informationGSV-1A4 M12/2 M12/2. Highlights
GSV-1A4 M12/2 M12/2 Highlights Input sensitivity: 2mV/V; 4mV/V, 2 mv/v, 1mV/V, 0.5mV/V configurable via jumpers Output signals ±10V AND 12mA+-8mA on 15 pin Sub-D Integrated half and quarter bridge completion
More informationModel 500 Digital Weight Indicator
Rev. 1.10 Serial Number: Model 500 Digital Weight Indicator USER MANUAL 1992-2000, Reliable Scale Corporation Reliable Scale Corporation 520 Moraine Road NE Calgary, Alberta, Canada Tel:1-800-419-1189
More informationTruckweigh. operators sheet STGGLOBAL.NET
Truckweigh operators sheet 1300 998 784 STGGLOBAL.NET FRONT PANEL FUNCTIONALITY The various screens and menus are accessed using the four buttons located around the LCD display, described briefly below.
More informationIPM500 Series QuickStart Manual
IPM500 Series QuickStart Manual The Force of Innovation 10 Thomas Irvine, CA 92618 USA (949) 465-0900 FAX: (949) 465-0905 E-Mail: HTUfutek@futek.comUTH www.futek.com Manufacturer of Load Cells, Pressure
More informationD-500s Indicator D LED. User Instructions. English Issue September SangR. Page 2. User s manual of Sang D-500s LED
D-500s Indicator D - 500 LED User Instructions English 8921-004210 Issue September 2010 1 2-2 0 1 0 D 6 0 0 4 6 7 5 Page 2 D-500s Indicator Page 2 Table of Content Section 1: Introduction. 1.1 Introduction
More informationUSER INSTRUCTION MANUAL FOR LOADCELL TRANSMITTER MODEL TDC/I/0550 (SOFTWARE: VER2A) INDEX
USER INSTRUCTION MANUAL FOR LOADCELL TRANSMITTER MODEL TDC/I/0550 (SOFTWARE: VER2A) INDEX DOCUMENT NO: TDC 0550 MANUAL - 2 1.0) INTRODUCTION. PAGE 2 1.1) ABOUT THIS MANUAL. PAGE 2 1.2) INTRODUCTION. PAGE
More informationMulti-Function Smart Indicator User Manual
Multi-Function Smart Indicator User Manual EC30006 Content 1 Notice... 2 2 Specification... 2 3 Main parameter... 3 4 How to fix... 3 5 Port... 4 6 On/Off... 4 7 Charging... 4 8 Display... 5 9 Screen keypad...
More informationIPM650 Intelligent Panel-Mount Display
Quick Start Guide IPM650 Intelligent Panel-Mount Display Sensor Solutions Source Load Torque Pressure Multi Component Calibration Instruments Software www.futek.com Getting Help TECHNICAL SUPPORT For more
More informationStrain gauge Measuring Amplifier GSV-1A8. Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB
Strain gauge Measuring Amplifier GSV-1A8 Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB GSV-1A8USB SubD1 (front side) GSV-1A8USB M12 (front side) GSV-1A16USB (rear side) GSV-1A8USB K6D (front side)
More informationTechnical Parameter... 4 Installation and Connection... 5
2 CONTENTS Technical Parameter... 4 Installation and Connection... 5 1. Indicator Diagram... 5 2. Loadcell Connection... 6 3. Serial Communication interface and Scoreboard... 7 Operation Instruction...
More informationFORCE PLATE. 400 Series Performance Force Plate Manual THIS MANUAL SHOULD BE READ AND UNDERSTOOD BEFORE OPERATING THIS FORCE PLATE
FORCE PLATE 400 Series Performance Force Plate Manual THIS MANUAL SHOULD BE READ AND UNDERSTOOD BEFORE OPERATING THIS FORCE PLATE Fitness Technology 21 Bishop St. Skye SA 5072 Australia +61 8 8331 9229
More informationKOBOLD TDA Series Digital Temperature Transmitter
KOBOLD TDA Series Digital Temperature Transmitter TDA-15 Series User Instructions KOBOLD Instruments Inc. 1801 Parkway View Drive Pittsburgh, PA 15205 Phone (412) 788-2830 Fax (412)-788-4890 www.koboldusa.com
More informationCAPITAL SCALE CC TEL: (012) FAX: CELL: ADVANCED MASS MEASUREMENT
CAPITAL SCALE CC TEL: (012) 259 3990 FAX: 086 656 2626 CELL: 082 782 0035 ADVANCED MASS MEASUREMENT Instruments KW-MSABS approved - SA1495 Standard Housing: ABS plastic Internal counts: 600000 Keypad:
More informationTrade Approved Version NMI: S520
@Weigh BW/BWS Series Trade Approved Version NMI: S520 Weighing Indicator User s guide UGBW-E1.09 Table of Contents SECTION 1 INTRODUCTION. 1 SECTION 2 SPECIFICATIONS... 2 SECTION 3 INSTALLATION.3 3. 1
More informationWEIGHING CONTROLLER TYPE MCE9625G
Kokkedal Industripark 4 DK-2980 Kokkedal Denmark Tel: +45 49 18 01 00 Fax: +45 49 18 02 00 WEIGHING CONTROLLER TYPE MCE9625G Installation guide for system with digital loadcells and LCD display Document
More informationKOBOLD PDA Series Digital Pressure Transmitter
KOBOLD PDA Series Digital Pressure Transmitter PDA-153 Series User Instructions KOBOLD Instruments Inc. 1801 Parkway View Drive Pittsburgh, PA 15205 Phone (412) 788-2830 Fax (412)-788-4890 www.koboldusa.com
More informationMicro USB Lamp Kit ESSENTIAL INFORMATION. Version 2.0 DESIGN A STYLISH LAMP WITH THIS
ESSENTIAL INFORMATION BUILD INSTRUCTIONS CHECKING YOUR PCB & FAULT-FINDING MECHANICAL DETAILS HOW THE KIT WORKS DESIGN A STYLISH LAMP WITH THIS Micro USB Lamp Kit Version 2.0 Build Instructions Before
More informationAFCS Fluid Guard 2 Model
671108 SRVIC GUID AFCS Fluid Guard 2 Model 343596 Alemite, LLC 167 Roweland Drive, Johnson City, Tennessee 37601 www.alemite.com Copyright 2016 by Alemite, LLC FORM: 671108 Version 1 Contents xplanation
More informationInstallation & Calibration Manual
IMPORTANT NOTE: Please read first the HID ProxPoint Plus card reader information on the end of this manual referring to the programming method that is required to get the system up and running. RFID Proximity
More informationModel No Load Indicator with Peak Hold Manual
Embedded System Laboratories Pvt. Ltd. (An ISO 9001:2008 certified company) Model No.-0501-5001 Load Indicator with Peak Hold Manual 86, Lane No. 7, Near Laxmi Dairy, Gurudwara Road, Jawahar Colony, N.I.T.
More informationHandheld force display AE 703
Handheld force display AE 703 Original of Manual Marschnerstraße 26 01307 Dresden, Germany Phone +49 3 51 44 55 30 Fax +49 3 51 44 55 555 www.ast.de vertrieb.dd@ast.de 1 Contents 1. Scope of use... 1
More informationZBXYAF Oxygen sensor control circuit board
FEATURES Control circuit board for all XYA series oxygen sensors Measuring ranges...5 or... oxygen or custom adjustable range Can be calibrated in normal air or any known O concentration Automatic or manual
More informationTELIKOU Intercom System. FM Wire Matrix Control Station. Instruction Manual
Intercom System FM-804 4-Wire Matrix Control Station Instruction Manual Systems All Rights Reserved I. Introduction Thank you for choosing intercom product. FM-804 is a eight channel four wire matrix control
More informationWeighing Indicator Service Manual V1.24X
Weighing Indicator Service Manual V1.24X CONTENTS 1. PRECAUTIONS.3 2. SPECIFICATIONS....4 3. INTRODUCTION....5 4. INSTALLATION..6 Unpacking 6 Installation 6 Load cell connections......7 Connect Adaptor
More informationKCD-HP. KCD-HP200x, 300X. [Figures] Top : 1% Sensor probe Bottom left : 10% / 20% Sensor probe Bottom right : Holding bracket(optional) Measurement
Our CO2 gas sensors get a small deviation unlike NDIR Single type. So they keep long term stability. KCD-HP100x Excellent stability and accuracy - through testing and calibration with sophisticated process
More informationParrot MULTICAN for Mini cars (part 2)
Parrot MULTICAN for Mini cars (part 2) - 1 - Parrot MULTICAN is a unit able to control Parrot H/F kits with the car s steering wheel commands working with ANALOG STEERING WHEEL COMMANDS with OEM headunit
More informationPS-IN202 Weighing Indicator User Manual
PS-IN202 Weighing Indicator User Manual Version 2015.05 Contents FRONT AND REAR VIEW OF THE INDICATOR CHAPTER 1 CONNECTIONS 1.1 WHAT'S IN THE BOX 1.2 CONNECTING TO THE WEIGH PLATFORM 1.3 CONNECTION TO
More informationSupply Voltage V dc Supply is fully isolated internally, and protected against transients. Internal power modules are CE certified.
Features Precision closed loop inertial sensor with optical position feedback and fluid damping Single axis measurement range ±5 to ±45 High resolution measurement
More informationEXCELL PRECISION CO., LTD.
Excell Precision Limited 24. All rights reserved Worldwide. The information contained herein is the property of Excell Precision Limited and is supplied without liability for errors or omissions. No part
More informationCOMPLETE MANUAL. WEIGHING INDICATOR TI-1200 and TI-1200-S TI-1200 with rechargeable battery.
COMPLETE MANUAL WEIGHING INDICATOR TI-1200 and TI-1200-S TI-1200 with rechargeable battery. TI-1200-S without rechargeable battery and with a smaller cabinet. Note: When TI-1200 is shipped as a part of
More information9. FUNCTION MENU SETTINGS -TION FUNCTION DESCRIPTION DEFAULT. VALUE F0 H-L SEt Lo Set a value for the Low
ROW Weighing Scale CONTENTS 1. INTRODUCTION 1 2. KEY DESCRIPTIONS 1 3. BASIC OPERATION.. 2 3.1 Zeroing the display..2 3.2 Taring. 2 4. CHECK-WEIGHING..3 4.1 About check-weighing 3 4.2 Set limits 4 4.3
More informationOperating Bulletin. Model BB3-232 and BB3-I-232 USB Multi-Drop Box. The Fastest Flow Controller Company in the World!
Operating Bulletin Model BB3-232 and BB3-I-232 USB Multi-Drop Box The Fastest Flow Controller Company in the World! 1 10/16/2017 Rev.1 DOC-BB3232MAN 2 Introduction Alicat BB3-232 Multi-Drop Box Operating
More informationVBAR 270. User Manual. Version 1.2
VBAR 270 User Manual Version 1.2 VBAR 270 User Manual Page 1of 19 Introduction Thank you for purchasing VBAR 270. VBAR 270 is a LED light fixture for professional use. Using the RGB color mixing technology
More informationParrot MULTICOMM For Mitsubishi steering wheel
Parrot MULTICOMM For Mitsubishi steering wheel - 1 - Parrot MULTICOMM is a unit able to control Parrot H/F kits with the car s steering wheel commands working with ANALOG STEERING WHEEL COMMANDS with OEM
More informationSartorius MP8 Series Balances and Scales
Sartorius MP8 Series Balances and Scales Making Changes to the Balance Operating Program 1) The Program Locking Switch Before any changes can be made to the balance operating program you must first unlock
More informationUser Manual. PCKeypad Wireless Keypad
User Manual PCKeypad Wireless Keypad Description The PCKeypad is a wireless keypad with a PentaCODE transmitter built-in. It works with all of Elsema s PCR series receivers. The installer has the option
More informationCRANE SCALE OCS-ABG : CALIBRATION Models: OCS-M & OCS-L
CRANE SCALE OCS-ABG : CALIBRATION Models: OCS-M & OCS-L You can use the Far control changes parameter and adjust. Each key function [ TARE ] Move [ 0 ] Choice [ MR ] The parameter choice Press [ F2 ] [
More informationOptima OP-902 User Manual
Optima OP-902 User Manual Warnings For safety operation of the weighing indicator, please follow the following warning/ safety instructions: Calibration inspection and maintenance of the indicator are
More informationLego Controller Version1.8
Lego Controller Version1.8 The University of Toronto Lego Controller consists of two parts, a Breakout box (figure 1) and a Lego controller (figure2) 1 The 16 pin header on the Lego controller connects
More informationASDA-B2 Servo System Quick Start Guide
ASDA-B2 Servo System Quick Start Guide This guide is intended as a quick start guide. On our website you can find also the full manual for the DELTA ASDA-B2 AC servo system, use this when getting into
More informationConnecting and Calibrating a Load Cell with V-Link
TN-W0026 MicroStrain Technical Note Connecting and Calibrating a Load Cell with V-Link V-Link and Futek LSB300 Load Cell (Applies to V-Link, SG-Link, SG-Link OEM, HS-Link ) Overview MicroStrain s V-Link
More informationUser s Manual of Web monitor HMI-901
User s Manual of Web monitor HMI-901 Afore New Energy Technology (Shanghai) Co., Ltd. 1. Wiring 1.1 Definition of different wire (picture 1-1): Colour Red Black Yellow White Definition +5V GND 485A 485B
More informationRD-SR2 ACCESS SECURITY PRODUCTS LTD. Proximity Card Reader with Remote Control. User Manual
RD-SR2 Proximity Card Reader with Remote Control User Manual INTRODUCTION The RD-SR2 is a compact, weather resistant multi-function card reader that can be used as a standalone programmable access control
More informationHI 6600 series Quick Start Guide
HI 6600 series Quick Start Guide HI 6600 series is a modular system of weight processors that can deliver up to 30 channels of fast, stable, high resolution weight values to PLCs, PACs and DSCs over a
More informationEA15 CALIBRATION PROCEDURE
EICMEA15-CP April 2006 Revision: Release EA15 CALIBRATION PROCEDURE Written By: Miguel Menendez Approved By: Date Approved: Robert Godzwon 2 of 7 Revision Log Revision Number Date Approved April 2006 Pages
More informationDevice: LDP This document Version: 1.0. Date: July Description: 80x08 1R1G LED Display Panel
Device: LDP-8008 This document Version: 1.0 Date: July 2010 Description: 80x08 1R1G LED Display Panel Table of Contents Introduction... 3 Nomenclature... 3 Connections... 3 Power... 3 Pinouts... 4 Controlling
More informationThis document hosted by: 10. OPTIONS
This document hosted by: www.oldwillknottscales.com 10. OPTIONS The following options are available for the FG series: OP-23 (FG-23) RS-232C serial interface OP-24 (FG-24) RS-232C serial interface and
More informationParrot MULTICOMM For FORD steering wheel
Parrot MULTICOMM For FORD steering wheel - 1 - Parrot MULTICOMM is a unit able to control Parrot H/F kits with the car s steering wheel commands working with ANALOG STEERING WHEEL COMMANDS with OEM headunit
More informationPower connections 3) Power from 2024 to Control box (The valve harness connected) Ground (0V) +24 V. The voltage between pins 1 & 2 in JPT# 123
Power connections 3) Power from 2024 to Control box (The valve harness connected) The voltage between pins 1 & 2 in JPT# 123 connector should be +24V. 4) Power from 2024 to Control box The voltage between
More informationStrain gauge Measuring Amplifier GSV-1A8. Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB
Strain gauge Measuring Amplifier GSV-A8 Instruction manual GSV-A8, GSV-A8USB, GSV-A6USB GSV-A8USB SubD5 (front side) GSV-A8USB M2 (front side) GSV-A6USB (rear side) GSV-A8USB K6D (front side) Version:
More informationSDI Speed Dome Camera OSD Menu
SDI Speed Dome Camera OSD Menu Indoor/ Outdoor Ver 1.2 00P9SH720ZXSEA2 Table of Contents 1. OSD Menu Tree...4 2. Configuration Menu...7 2.1 VIDEO TYPE...8 2.2 DEFAULT CAMERA...8 2.3 BACKLIGHT...8 2.4 FOCUS...8
More informationCV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions
CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions Packing List NAME MODEL/SIZE QTY Self tapping screw 0.15 x 1.06 (4mm 27 mm) Rubber plug 0.23 x 1.2 (6mm 30 mm) Star screw driver
More informationF6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode
-Fingerprint Access Control/Reader Function Description Enter the Programming Mode - Simplified Instruction Operation (Factory default:1234) Change the Master Code Add Fingerprint User Add Card User Add
More information6A27 6A40 6A68 6A154 6A175
6A154 Interface's 6-axis load cell measures forces simultaneously in three mutually perpendicular axes and three simultaneous torques about those same axes. Six full bridges provide mv/v output on six
More informationInsight Installation of FX30 Data Acquisition Unit (DAU) Login to Insight Setup Insight with your equipment in the cloud Related system information
QUICK START GUIDE Insight Installation of FX30 Data Acquisition Unit (DAU) Login to Insight Setup Insight with your equipment in the cloud Related system information DEIF A/S Frisenborgvej 33 DK-7800 Skive
More informationSY021 Portable Load/Force Meter User instructions
SY021 Portable Load/Force Meter User instructions Relates to firmware version 5.2 INTRODUCTION The SY021 is a portable load meter, which can indicate the load present on any attached cell. A dual channel
More informationECI1. COMPASS display. ECI1-REV For latest update: Electronic Compass Indicator ECS1
ECI1 COMPASS display Electronic Compass Indicator ECS1 ECI1-REV. 1.3 20-12-2004 For latest update: www.elproma.com/compass Contents 1 Introduction... 1 1.1 Package contents... 1 2 Working... 2 2.1 The
More informationStock Weigh 300. Operators Manual HELLO. Ft. Atkinson, Wisconsin USA. Panningen, The Netherlands
Stock Weigh 300 Operators Manual HELLO Ft. Atkinson, Wisconsin USA Panningen, The Netherlands www.digi-star.com D3734-US REV E October 31 st, 2012 SW300 User s Manual D3734-US REV E TABLE OF CONTENTS Table
More informationParrot Reference : - If you are interested, contact our sales department :
- 1 - Parrot MULTICAN for Mercedes cars Parrot MULTICAN is a unit able to control Parrot H/F kits with the car s steering wheel commands working with CANBUS or K-BUS systems. This unit is available in
More informationCalibration & Connectivity
Calibration & Connectivity TS-700 Series Digital Indicators This document supplements the User s Guide TS-700 MS TS-700 SS TS-700 WB Full Function/Advanced Function Digital Indicator www.trinerscale.com
More informationDCS Series. Digital Counting Scale. Setup Manual
DCS Series Digital Counting Scale Setup Manual Revision 1.1 February 12, 1997 1996-1997 Transcell Technology, Inc. Contents subject to change without notice. Transcell Technology, Inc. 975 Deerfield Parkway
More informationANNEX A DRAWINGS. Technology and reliability that carries weight. Document Date Code Rev. Page
Technology and reliability that carries weight ANNEX A DRAWINGS. LD04 SYSTEM BLOCK DIAGRAM LD04/80/00. LD04 ENCLOSURE DIMENSIONS (ALUMINIUM/PLASTIC) LD04/80/00. LD04 ENCLOSURE DIMENSIONS (INOX) LD04/80/0
More informationw w w. p r o l i g h t. c o. u k STAGE PAR 64
w w w. p r o l i g h t. c o. u k STAGE PAR 64 Order code: LEDJ40 (Black) Order code: LEDJ41 (Polished) Order code: LEDJ42 (Black) Order code: LEDJ43 (Polished) Order code: LEDJ44 (Black) Order code: LEDJ45
More informationAUTOMATION. Operator s Manual PG-7. Full Access. Doc Part Rev B, 07/18. Automation Products Group, Inc.
AUTOMATION P R O D U C T S GROUP, INC. Operator s Manual PG-7 Full Access Doc. 9003312 Part 200180 Rev B, 07/18 Tel: 1/888/525-7300 Fax: 1/435/753-7490 www.apgsensors.com E-mail: sales@apgsensors.com PG7
More information5024 WEIGHING TERMINAL
Kokkedal Industripark 4 DK-2980 Kokkedal Denmark info@eilersen.com Tel +45 49 180 100 Fax +45 49 180 200 5024 WEIGHING TERMINAL Basic system with automatic dosing Applies to: Software: Document no.: STDLIM.140630.2v0
More informationSPECIFICATIONS Temperature Setting Range: Ambient Temperature Humidity Display Range: Screen lock & configuration password:
1 FEATURES 5-inch touch & color screen Humanized operator interface Two kinds of display style Schedule setting in simple way Control your device with your cell-phone Compressor protection 12 wiring connections
More informationDRAFT. Customer site gravity factor. Filtering parameters. Five points for linearity correction to ensure maximum accuracy
Avery Weigh-Tronix Technical Specification Description General This specification describes the indicator, capable of stand-alone operation, or of integration into a larger system via serial interface.
More information! User Manual Rev. 1
User Manual Rev. 1 Warnings For safety operation of the weighing indicator, please follow the following warning/ safety instructions: Calibration inspection and maintenance of the indicator are prohibited
More informationSartorius XQ 6100, XQ 6100 B.
Sartorius XQ 6100, XQ 6100 B. Electronic Paint Mixing Scales Installation and Operating Instructions Sartorius XQ 6100, XQ 6100 B. Please read these installation and operating instructions carefully before
More informationAPEX Junior Cased Weighing Indicator/Controller
APEX Junior Cased Weighing Indicator/Controller Non-Trade User Manual www.pcm-uk.com APPROVED DISTRIBUTORS OF: Electronic Weighing Services 1 Index Section 1: Setting Up (Terminations and time/date routines)
More information5000 Series Bench Scale Platforms
Service / Installation Manual 5000 Series Bench Scale Platforms 51245 2010-2013 by Fairbanks Scales, Inc. Revision 3 07/13 All rights reserved Amendment Record 5000 SERIES BENCH SCALE PLATFORMS SERVICE
More informationQUICK INSTALLATION. MSX-E3511 Ethernet analog output system /2016
QUICK INSTALLATION MSX-E11 Ethernet analog output system 02.0-01/2016 Addi-data GmbH Airpark Business Center Airport Boulevard B210 7786 Rheinmünster Germany Phone: +9 7229 187-0 Fax: +9 7229 187-222 info@addi-data.com
More informationHI 6600 series Quick Start Guide
HI 6600 series Quick Start Guide HI 6600 series is a modular system of weight processors that can deliver up to 30 channels of fast, stable, high-resolution weight values to PLCs, PACs and DSCs over a
More informationEL-ST100 KEYPAD CONTROLLER
WIRING DIAGRAM EL-ST100 KEYPAD CONTROLLER WEATHER-PROOF STANDALONE ACCESS CONTROLLER WITH KEYPAD & PROXIMITY TECHNOLOGY Programming and Installation Manual NOTE: www.elock2u.com ICT at work! Version 3.6
More informationGT 400 Operators Manual
GT 400 Operators Manual Ft. Atkinson, Wisconsin USA Panningen, The Netherlands www.digi-star.com D3831-US REV A February 27, 2009 TABLE OF CONTENTS GT400 TABLE OF CONTENTS... 2 CHARGING BATTERY OR WELDING...
More informationAUTOMATION. Operator s Manual. PG5 Digital Pressure Gauge
AUTOMATION P R O D U C T S GROUP, INC. Operator s Manual PG5 Digital Pressure Gauge DOC. 9003264 Rev. A1 3/10 Tel: 1/888/525-7300 Fax: 1/435/753-7490 www.apgsensors.com E-mail: sales@apgsensors.com PG5
More informationPlug-in unit extension block One sensor extension block allows four plug-in units to be added. Power cable for sensors. Snap-connector inputs
1 Sensor Block for SC Quick connection of 16 sensors Set of 16 inputs directly hooked up to PLC Up to 16 sensors can be connected on one main block followed by three extension blocks (or one snapconnector
More informationHI-POT TESTER. User s Manual
HI-POT TESTER 7620 User s Manual Contents 1. Before Use... 1.1Electric Shock Avoidance... 4 1.2 Grounding... 4 1.3 AC Power Supply... 4 1.4 Connecting Test Leads... 4 1.5 Warm Up... 4 1.6 External Control...
More informationBS-105 Digital Indicator
BS-105 Digital Indicator The Better Way for Weighing & Measurements 1 CONTENTS Introductions.......... 2 The Features of BS-105.. 3 Technical Specification.. Dimensions............. 6 Front Panel............
More informationLuxline driver. LL-PCB-LUXlinedriver. Lux Lumen bvba Kernenergiestr. 53a 2610 Wilrijk. Luxline driver - page 1 T F
Luxline driver LL-PCB-LUXlinedriver Lux Lumen bvba Kernenergiestr. 53a 2610 Wilrijk 10200 T +32 3 293 35 50 F +32 3 293 35 44 Luxline driver - page 1 Content PCB Layout Placement Connectors Supply Wago
More informationSERVICE MANUAL iforks
SERVICE MANUAL iforks Rev.28.09.09 SERVICE MANUAL iforks 1 Table of contents page 1. Calibration 3 1.1 Corner calibration 3 1.2 Zero calibration 6 1.3 Weight calibration 7 2. Parameter settings 11 3. Indicator
More informationIMPORTANT AS YOU REMOVE THE CONNECTORS LABEL THE CONNECTOR WITH THE NAME OF PLUG WITH THE SHARPIE
TOOLS REQUIRED : small flat head screwdriver no wider than ⅛ or 3mm wide, phillips head screwdriver, 3mm allen wrench, self tapping screws #6 x ½, ¼ hex head driver, electric drill, wire cutters, fine
More informationInstallation & Operation Manual Revision 2
MULTI-C1 IN-PARLOUR FEEDING Installation & Operation Manual Revision 2 PAGE 1 INDEX Overview Setting Up 3 Parlour Parameters - Parlour Size - Feeder Type - Pulse/Portion Time 4 4 4 Manufacturer Feed Dispenser
More informationWarning! It will cause malfunction if the monitor is operating with unspecified power supply adaptor or incorrect power voltage. Do not expose this
User Manual / Installation Guide Model No. P150VR/P150VG Warning! It will cause malfunction if the monitor is operating with unspecified power supply adaptor or incorrect power voltage. Do not expose this
More informationPCE Americas Inc. PCE Instruments UK Ltd. 711 Commerce Way Units 12/13, Southpoint Business Park Suite 8 Ensign Way Jupiter, FL 33458 Hampshire / Southampton USA United Kingdom, SO31 4RF Phone: 561-320-9162
More informationQuick Reference Guide
Ilumipod 42 IP Series Quick Reference Guide About this Guide Disclaimer The Ilumipod 42 IP Series Quick Reference Guide (QRG) only contains the product s connection and mounting information as well as
More informationMEITRACK MVT340 User Guide
MEITRACK MVT340 User Guide Change History File Name MEITRACK MVT340 User Guide Created By Kyle Lv Project MVT340 Creation Date Update Date 2010-08-24 2017-03-23 Subproject User Guide Total Pages 12 Version
More informationQUICK INSTALLATION. MSX-E1731 Ethernet multifunction counter system /2016
QUICK INSTALLATION MSX-E1731 Ethernet multifunction counter system 02.04-01/2016 Addi-data GmbH Airpark Business Center Airport Boulevard B210 77836 Rheinmünster Germany Phone: +49 7229 1847-0 Fax: +49
More informationHOWTO Make an Initial Connection to the Office Anywhere Desktop using a Windows 7 based PC v1
HOWTO Make an Initial Connection to the Office Anywhere Desktop using a Windows 7 based PC v1 1. Web browse to the Office Anywhere Portal: http://hosted.gg (as shown below) 2. Click the Access Office Anywhere
More informationTotalcomp TLI Indicator. Operation and Maintenance Manual Manual
Totalcomp TLI Indicator Operation and Maintenance Manual Manual V1.08-0.06E DT: 04/29/2013 - - CONTENTS Precautions... 2 1. SPECIFICATIONS... 3 2. INTRODUCTION. 4 3. INSTALLATION... 5 Unpacking 5 Parts
More informationTOUCHBOX. iphone I N S T R U C T I O N M A N U A L
TOUCHBOX W I R E L E S S C O N T R O L L E R iphone I N S T R U C T I O N M A N U A L Thank you for purchasing TouchBox by ZAETECH. Disclaimer TouchBox is for show and off road use only. It may not be
More information