AFCS Fluid Guard 2 Model

Size: px
Start display at page:

Download "AFCS Fluid Guard 2 Model"

Transcription

1 SRVIC GUID AFCS Fluid Guard 2 Model Alemite, LLC 167 Roweland Drive, Johnson City, Tennessee Copyright 2016 by Alemite, LLC FORM: Version 1

2 Contents xplanation of safety signals Safety Introduction... 2 Controller overview Overview User interface xplanation of safety signals Safety Read and carefully observe installation instructions before installing, operating or troubleshooting referenced equipment. quipment must be installed, maintained and repaired exclusively by persons familiar with instructions. While unpacking, check unit is complete and free from damage. Install unit so that: power supply cords/wiring are secured away from vehicle and other types of contact. unit is not near or over heat. unit is properly grounded. AFCS Fluid Guard must be equipped with plug having third (grounding) pin that only fits into grounding type outlet. This is a safety feature. Do not use without properly grounded outlet. Failure to properly ground AFCS Fluid Guard may cause damage to unit or data stored. Introduction note AFCS Fluid Guard model is designed to be incorporated into fluid dispensing system for management of oil dispense points. The system controls 2 different fluids and twelve total hoses. Using the AFCS Fluid Guard allows for the dispensing of one fluid to twelve hoses or two fluids to six hoses. For indoor use only, not for outdoor use. Danger Indicates a hazardous situation that if not avoided, will result in death or serious injury. Warning Indicates a hazardous situation that, if not avoided, may result in death or serious injury. Caution Indicates a hazardous situation that,if not avoided, could result in minor or moderate injury. Danger Disconnect all power supplied to system before performing any installation or maintenance. Failure to comply will result in death or serious injury. Product specification Temperature range Net weight Input voltage Minimum current Maximum current Pulse switch voltage Pulse switch current Valve output voltage Maximum valve output current Table 1 32 to 122 F (0 to 50 C) 2.5 lbs. (1,134 kg) V AC, Hz 0.25 A 2.0 A 24 V 5.1 ma 24 V 1.85 A Alemite, LLC

3 Controller overview Fig. 1 Single fluid systems Master 1 AFCS Fluid Guard Pulser 1 Hose 1 Hose 2 Wiring Diagram +24 V DC Hose x Solenoid valve coil Air valve Air pump Pulse meter Fluid valve 1 Fluid valve 2 X 12 (hoses 1 thru 12) Wiring Diagram +24 V DC Pulse meter Site tank Pulse meter input x Dual fluid systems Air valve Air pump Master 1 Pulse meter 1 Pulser 1 Pulser 2 Hose 2 Hose 8 Fluid valve 2 Hose 1 Fluid valve 1 AFCS Fluid Guard Hose 7 Fluid valve 7 Fluid valve 8 Master 2 Pulse meter 2 Air pump X 6 X 6 (hoses 1 (hoses 7 thru 6) thru 12) Site tank 1 Site tank 2 Air valve Alemite, LLC

4 Overview Danger Disconnect all power supplied to AFCS Fluid Guard before performing installation or wiring. Failure to comply will result in death or serious injury. note Do not leave electrical wires uncovered. Cover wires not used with wire nut. Failure to comply may result in damage to equipment. Fig Item Description 1 Touchscreen 2 Screen keypad 3 Power switch 4 Key 1) 5 Dispense presets 6 Interface cable 1) Order replacement key, part number , as needed. 6 Wire Color Function Violet +24 V DC output to solenoid or pulse meter White/red +24 V DC output to solenoid or pulse meter White/green +24 V DC output to solenoid or pulse meter White/yellow +24 V DC output to solenoid or pulse meter Red/green Master solenoid output 1 (hoses 1-12 for single fluid system, hoses 1-6 for dual fluid system) Red/yellow Master solenoid output 2 (inactive for single fluid system, hoses 7-12 for dual fluid system) Red/black Pulse switch input 1 (hoses 1-12 for single fluid system, hoses 1-6 for dual fluid system) White/black Pulse switch input 2 (inactive for single fluid system, hoses 7-12 for dual fluid system) Yellow Hose 1 Brown Hose 2 Blue Hose 3 Orange Hose 4 Green Hose 5 White Hose 6 Red Hose 7 Black Hose 8 White/blue Hose 9 Slate Hose 10 Pink Hose 11 Tan Hose Alemite, LLC

5 User interface Fig. 3 Programming interface To get to configuration programming interface, key lock must be in position. Configuration programming interface is run entirely by touch screen LCD and cannot be modified by keypad. To enter configuration programming screen select System Configuration, enter passcode (1357) and press OK. Successfully entering passcode will bring up Configuration Options. Fluid 1 Volume (Qt.) Total: Trip: 70.3 Fluid 2 Volume (Qt.) Total: Trip: 70.3 System Configuration Reset Reset (or choose preset option on touchscreen). touchscreen, or button. note To revert to previous screen, select X in top left corner. Fig. 4 Fluid 1 Volume (Qt.) Total: Trip: 70.3 Reset X 1357 X nter Password Configuration Options Fluid 2 Volume (Qt.) Total: Trip: Reset Change Fluid Mode Change Volume Units Change Quick Select Values System Configuration < 0 OK Change PPU Values Alemite, LLC

6 Select option you wish to modify and screen will move appropriately. Fig. 5 X Select Fluid Mode Currently Set to Dual X Select Volume Unit Currently Set to Quarts Change To Quarts Change To Liters X Change To Gallons Change to Single Configuration Options Change Fluid Mode Change To Pints X Change Volume Units X Set Pulses Per Unit Change Quick Select Values Quick Select Config Fluid 1 PPU: Change PPU Values Quick Select 1: Fluid 2 PPU: Quick Select 2: Quick Select 3: Configuration changes are automatically updated on screen as they are made. When finished changing System Configuration, return lock key to position to save changes. Fluid 1 Volume (Qt.) Total: Trip: Saving 70.3 Configuration Reset... Fluid 2 Volume (Qt.) Total: Trip: 70.3 Reset or choose preset option on touchscreen). touchscreen, or button. Fig. 6 System Configuration Alemite, LLC

7 Oil dispensing interface To get to oil dispensing interface, key lock must be in position. Fig Frequently Used Values Quick Select Values Use keypad directional to pad enter to enter quantity quantity (or or choose preset option on touchscreen) To To end dispense, press cancel button on touchscreen, or button. Choose option from Request Quantity screen to load Quick Select or Frequently Used value. Fig Frequently Used Values Quick Select Values or choose preset option on touchscreen). touchscreen, or button. Alemite, LLC

8 note To modify value in tenths of a unit, use up and down arrows on keypad. Fig Frequently Used Values or choose preset option on touchscreen). touchscreen, or button Quick Select Values Once desired Request Quantity is shown, desired hose must be selected from numbered keypad to activate. When requested volume has been dispensed, system will save new dispense data. 4.4 (Qt.) or choose preset option on touchscreen). touchscreen, or button. Fig. 10 Of Requested 4.4 Have Been Dispensed Saving... If dispense needs to be ended prior to reaching requested quantity, dispense request can be ended early by pressing nd Dispense on touchscreen or by pressing on keypad. 3.1 (Qt.) or choose preset option on touchscreen). touchscreen, or button. Fig. 11 Of Requested 4.4 Have Been Dispensed nd Dispense Alemite, LLC

9 System will save new dispense data to memory. Fig (Qt.) or choose preset option on touchscreen). touchscreen, or button. Of Requested 4.4 Have Been Dispensed Saving... After data is saved to memory, system will return to Request Quantity screen and new oil dispense can be requested. Fig Frequently Used Values Quick Select Values Use Use keypad directional on to pad enter to enter quantity quantity (or or choose choose preset preset option option on on touchscreen) touchscreen) Choose Choose desired desired hose hose from from number number pad pad To To end end dispense dispense, press press cancel cancel button on on touchscreen touchscreen, or button Alemite, LLC

10 This page left intentionally blank Alemite, LLC

11 This page left intentionally blank Alemite, LLC

12 Alemite, LLC 167 Roweland Drive, Johnson City, Tennessee

SERVICE GUIDE. AFCS ENTERPRISE TMW INTERFACE Model

SERVICE GUIDE. AFCS ENTERPRISE TMW INTERFACE Model 343592 SERVICE GUIDE Model 343592 Alemite, LLC 167 Roweland Drive, Johnson City, Tennessee 37601 www.alemite.com Copyright 2017 by Alemite, LLC FORM: 671117 Version 1 Contents Introduction.... 2 Sites....

More information

Model Alemite, LLC 167 Roweland Drive, Johnson City, Tennessee Copyright 2016 by Alemite, LLC FORM: Original

Model Alemite, LLC 167 Roweland Drive, Johnson City, Tennessee Copyright 2016 by Alemite, LLC FORM: Original 343537 SERVICE GUIDE AFCS Enterprise manager manual Model 343537 Alemite, LLC 167 Roweland Drive, Johnson City, Tennessee 37601 www.alemite.com Copyright 2016 by Alemite, LLC FORM: 671106 Original SER

More information

SERVICE GUIDE. AFCS ENTERPRISE CDK INTERFACE Model

SERVICE GUIDE. AFCS ENTERPRISE CDK INTERFACE Model 343586 SERVICE GUIDE AFCS ENTERPRISE CDK INTERFACE Model 343586 Alemite, LLC 167 Roweland Drive, Johnson City, Tennessee 37601 www.alemite.com Copyright 2017 by Alemite, LLC FORM: 671118 Version 1 SER

More information

COMFORT CONTROL CENTER SERVICE INSTRUCTIONS

COMFORT CONTROL CENTER SERVICE INSTRUCTIONS USA SERVICE OFFICE Dometic Corporation 2320 Industrial Parkway Elkhart, IN 46516 574-294-2511 CANADA Dometic Corporation 46 Zatonski, Unit 3 Brantford, ON N3T 5L8 CANADA 519-720-9578 For Service Center

More information

Installation and Operation Back-UPS BR1000G-IN / BR1500G-IN

Installation and Operation Back-UPS BR1000G-IN / BR1500G-IN Installation and Operation Back-UPS BR1000G-IN / BR1500G-IN Important Safety Information Read the instructions carefully to become familiar with the equipment before trying to install, operate, service

More information

LXEM145 SERIES Lanx Australis single Phase KWh Meter 45Amp. User manual

LXEM145 SERIES Lanx Australis single Phase KWh Meter 45Amp. User manual LXEM145 SERIES Lanx Australis single Phase KWh Meter 45Amp Single phase two wire DIN rail energy meter (One module) 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic

More information

PUMP DRIVE OPERA TING MANUAL: A Edition 01

PUMP DRIVE OPERA TING MANUAL: A Edition 01 OPERA TING MANUAL: PUMP DRIVE 77420-00 Pump Drive, shown with 77600-62 High Performance I/P Pump Head. 77420-00 A-1288-0990 Edition 01 1-800-637-3739 (U.S. and Canada only) 11 (847) 381-7050 (Outside U.S.)

More information

Installation Guide SMT 2200/3000 VA Input/Output Hardwire Kit

Installation Guide SMT 2200/3000 VA Input/Output Hardwire Kit Installation Guide SMT 2200/3000 VA Input/Output Hardwire Kit Important Safety Messages SAVE THESE INSTRUCTIONS - This section contains important instructions that should be followed during installation

More information

3700 SERIES USER MANUAL

3700 SERIES USER MANUAL SAFETY GUIDE This manual contains the precautions necessary to ensure your personal safety as well as for protection for the products and the connected equipment. These precautions are highlighted with

More information

ETM-2040 Service Manual

ETM-2040 Service Manual Introduction Novar s Electronic Thermostat Modules (ETMs) are intelligent control modules that provide local, direct digital control of unitary, packaged, staged HVAC systems. This document: Describes

More information

SDM120 SERIES. SDM120 series User Manual. Single phase two wire DIN rail energy meter (One module)

SDM120 SERIES. SDM120 series User Manual. Single phase two wire DIN rail energy meter (One module) SDM120 SERIES Single phase two wire DIN rail energy meter (One module) User manual ------------ 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Dimension

More information

DNG-200 LOW FOG GENERATOR USER MANUAL DNG-200 低煙機使用說明書

DNG-200 LOW FOG GENERATOR USER MANUAL DNG-200 低煙機使用說明書 DNG-200 LOW FOG GENERATOR USER MANUAL DNG-200 低煙機使用說明書 Read and save these insturctions 2008 Antari Lighting & Effects Ltd. User Manual Antari DNG-200 Low fog Generator Congratulations on the purchase

More information

Installation Instructions

Installation Instructions Installation Instructions Variable Frequency Drive (VFD) 7 ½ - 25 Ton Units with 2 Wire Control WARNING UNINTENDED EQUIPMENT OPERATION Modifying or changing parame eters whose function is not described

More information

HI-POT TESTER. User s Manual

HI-POT TESTER. User s Manual HI-POT TESTER 7620 User s Manual Contents 1. Before Use... 1.1Electric Shock Avoidance... 4 1.2 Grounding... 4 1.3 AC Power Supply... 4 1.4 Connecting Test Leads... 4 1.5 Warm Up... 4 1.6 External Control...

More information

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER SAFETY INFORMATION The following safety information must be observed to ensure maximum personal safety during the operation of this meter: This meter is

More information

Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating instructions. Switching amplifier DN0210 DN / / 2015 Operating instructions Switching amplifier DN0210 DN0220 UK 80011079 / 00 01 / 2015 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5

More information

AFCS Enterprise. Control fluids with your dealer management system. AFCS Enterprise benefits:

AFCS Enterprise. Control fluids with your dealer management system. AFCS Enterprise benefits: The AFCS Enterprise software and Alemite AFCS fluid inventory control and management system are designed to accurately track, monitor and dispense fluids in vehicle service applications. This fluid management

More information

High Pressure E/P Regulator. ITVH Series

High Pressure E/P Regulator. ITVH Series Doc. No. DIQ-69200-OM002-A P R O D U C T N A M E High Pressure E/P Regulator MODEL/ Series/ Product Number ITVH Series Install and operate the product only after reading the Operation Manual carefully

More information

Part No. Z , IA Mar OPERATION MANUAL. High Voltage Digitalmeter A

Part No. Z , IA Mar OPERATION MANUAL. High Voltage Digitalmeter A Part No. Z1-109-820, IA001704 Mar. 2011 OPERATION MANUAL High Voltage Digitalmeter 149-10A Use of Operation Manual Please read through and understand this Operation Manual before operating the product.

More information

L300 user manual. Programmable DC Electronic Load CONTENTS. Electronic Load Software CAUTION...2 SAFETY NOTES...2

L300 user manual. Programmable DC Electronic Load CONTENTS. Electronic Load Software CAUTION...2 SAFETY NOTES...2 Programmable DC Electronic Load L300 user manual CONTENTS CAUTION......2 SAFETY NOTES......2 Chapter 1 General Introduction...3 1.1 General Introduction......3 1.2 Specification......3 1.3 Features......3

More information

FAZE 800 FT PRO USER MANUAL. Version: 1.2. ROBE Lighting s.r.o. Czech Republic

FAZE 800 FT PRO USER MANUAL. Version: 1.2. ROBE Lighting s.r.o. Czech Republic FAZE 800 FT PRO USER MANUAL Version: 1.2 ROBE Lighting s.r.o. Czech Republic www.robe.cz FAZE 800 FT PRO Table of contents 1. Introduction 4 2. Cautions 4 3. Opening the package and inspecting the machine

More information

9212i INSTALLATION. Stand-Alone Keypad. Instructions

9212i INSTALLATION. Stand-Alone Keypad. Instructions INSTALLATION 9212i Stand-Alone Keypad Instructions Features: 4 Independent Outputs 4 Independent Timers All Outputs Assignable by Code On board 5 Amp Form C Relay 120 Users Remote Triggering Input Keypad

More information

XTM1250SA DIN rail three phase four wire LCD display energy meter

XTM1250SA DIN rail three phase four wire LCD display energy meter XTM1250SA DIN rail three phase four wire LCD display energy meter 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Intrinsic errors 1.6 Description 1.7 Dimensions 1.8

More information

ELECTRICAL SUPPLY TROUBLESHOOTING QUICK GUIDE SAFETY PRECAUTIONS

ELECTRICAL SUPPLY TROUBLESHOOTING QUICK GUIDE SAFETY PRECAUTIONS ELECTRICAL SUPPLY TROUBLESHOOTING QUICK GUIDE 1. Circuit Breaker Tripping 2. Circuit Overload 3. Short Circuit 4. Ground Fault 5. Ground Fault Circuit Interrupter (GFCI) Tripping SAFETY PRECAUTIONS Basic

More information

Operating Manual Bedienungsanleitung. Digital Dispense Controller

Operating Manual Bedienungsanleitung. Digital Dispense Controller Operating Manual Bedienungsanleitung Digital Dispense Controller 97101 Contents 1 Please observe the following...3 1.1 Emphasized Sections...3 1.2 Items Supplied...3 1.3 Field of Application (Intended

More information

ADVANTAGE DKE QUICK START GUIDE. 2 Make sure you have everything shown here. 3. What s what? All important internal components labeled for you

ADVANTAGE DKE QUICK START GUIDE. 2 Make sure you have everything shown here. 3. What s what? All important internal components labeled for you 1 of 6 START HERE 1 Carefully unpack box. 2 Make sure you have everything shown here. 3 Unlock and remove front panel of keypad unit, then using carriage bolts and hex nuts, attach unit to pedestal as

More information

AFCS Enterprise Administrator manual

AFCS Enterprise Administrator manual User and maintenance instructions AFCS Enterprise Administrator manual Model 343537 Date of issue October 2017 Form number 671107 Version 2 Contents Introduction...................... 2 Terms used.......................

More information

LFC 6000 and LFC Enterprise software. Control fluids with your management software programs

LFC 6000 and LFC Enterprise software. Control fluids with your management software programs LFC 6000 and LFC Enterprise software Control fluids with your management software programs Control fluids with your management software programs System provides ability to start a dispense from a shop

More information

M A C 3 Wind Speed Alarm & Controller

M A C 3 Wind Speed Alarm & Controller M A C 3 Wind Speed Alarm & Controller Installation Instructions Thank you for purchasing the MAC3 wind speed alarm and controller. This manual is designed to lead you through a step-by-step process to

More information

Part No. Z , IA Nov OPERATION MANUAL. High Voltage Digitalmeter A

Part No. Z , IA Nov OPERATION MANUAL. High Voltage Digitalmeter A Part No. Z1-109-920, IA001723 Nov. 2005 OPERATION MANUAL High Voltage Digitalmeter 149-30A Use of Operation Manual Please read through and understand this Operation Manual before operating the product.

More information

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS GB Contents Page 1 Introduction 4 2 Safety 5 3 Use 6 4 Checking on Delivered Equipment 6 5 General Specification and Dimensions 7 6 Positioning 10 7 Operating

More information

IO-INTERFACE. Procon. INSTALLATION MANUAL Version 1.01 MITSUBISHI ELECTRIC FOR INSTALLERS

IO-INTERFACE. Procon. INSTALLATION MANUAL Version 1.01 MITSUBISHI ELECTRIC FOR INSTALLERS Procon IO-INTERFACE FOR INSTALLERS INSTALLATION MANUAL Version 1.01 For safe and correct use, please read this installation manual thoroughly before installing the PROCON IO-INTERFACE. MITSUBISHI ELECTRIC

More information

4 Connection and interface

4 Connection and interface 4 Connection and interface EXPOSED SIGNALS! DANGER Hazardous voltage levels may be present if using an open frame power supply to power the product. Failure to follow these instructions will result in

More information

PRO1250D CT MID DIN rail three phase four wire energy meter. User manual Version 1.5

PRO1250D CT MID DIN rail three phase four wire energy meter. User manual Version 1.5 PRO1250D CT MID DIN rail three phase four wire energy meter. User manual Version 1.5 1 Safety instructions...3 2 Foreword...4 3 CE certificates...5 4 MID certificate...7 5 Performance criteria...8 6 Specifications...8

More information

FOR SERVICE TECHNICIAN S USE ONLY

FOR SERVICE TECHNICIAN S USE ONLY Tech Sheet Do not discard DANGER WARNING Electrical Shock Hazard Only authorized technicians should perform diagnostic voltage measurements. After performing voltage measurements, disconnect power before

More information

MOTION LABORATORIES CHAIN HOIST MOTOR CONTROL SYSTEMS MANUAL. Basic Outline of Operation for Distro Controllers

MOTION LABORATORIES CHAIN HOIST MOTOR CONTROL SYSTEMS MANUAL. Basic Outline of Operation for Distro Controllers MOTION LABORATORIES CHAIN HOIST MOTOR CONTROL SYSTEMS MANUAL Forward The main body of text in this manual concerns four through eight channel portable chain hoist motor control systems with 208-230 VAC

More information

Instruction Manual CTC-1

Instruction Manual CTC-1 Troubleshooting & Specs CTC-1 Amps / Volts requirements Min / Max operating temperature Min / Max operating Humidity Temperature Measurement range Temperature Accuracy CO2 sensor type CO2 Measurement range

More information

Operating instructions. Speed monitor D / / 2014

Operating instructions. Speed monitor D / / 2014 Operating instructions Speed monitor D200 80005257 / 00 05 / 2014 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5 2.2 Target group...5

More information

RAIN BIRD RC-4Bi, RC-7Bi, RC-1260Bi SERIES INSTRUCTION MANUAL

RAIN BIRD RC-4Bi, RC-7Bi, RC-1260Bi SERIES INSTRUCTION MANUAL RAIN BIRD RC-4Bi, RC-7Bi, RC-1260Bi SERIES INSTRUCTION MANUAL DESCRIPTION OF CONTROLS Refer to Figure 1 Figure 1 A. HOUR DIAL with 23 CYCLE START PINS The HOUR dial contains 23 pins for rescheduling automatic

More information

Operating Instructions STX Series Digital Strap Tension Meter

Operating Instructions STX Series Digital Strap Tension Meter TENSITRON 733 S. Bowen Street Longmont, CO 80501 USA Phone: (303) 702-1980 Fax: (303) 702-1982 E-mail: sales@tensitron.com Web Site: www.tensitron.com Operating Instructions STX Series Digital Strap Tension

More information

It's Here... Access Elevator Supply now offers Replacement Logic Boards for Siemens Class 72G Elevator Soft Starters. Easy to install and lightweight

It's Here... Access Elevator Supply now offers Replacement Logic Boards for Siemens Class 72G Elevator Soft Starters. Easy to install and lightweight It's Here... Access Elevator Supply now offers Replacement Logic Boards for Siemens Class 72G Elevator Soft Starters. Easy to install and lightweight to ship, these logic boards are a convenient solution

More information

DirectCommand Installation RoGator Model Year Ag Leader Technology

DirectCommand Installation RoGator Model Year Ag Leader Technology Note: Indented items indicate parts included in an assembly listed above Part Name/Description Part Number Quantity Direct Command Kit 4100801 1 Dual Lock 2000052-9 1 Dual Lock 2000053-9 1 Quick Reference

More information

Octostrip ORDERCODE 42220

Octostrip ORDERCODE 42220 Octostrip ORDERCODE 42220 Congratulations! You have bought a great, innovative product from Showtec. The Showtec LED Octostrip brings excitement to any venue. Whether you want simple plug-&-play action

More information

OPERATING INSTRUCTIONS PA AMPLIFIER P-1812

OPERATING INSTRUCTIONS PA AMPLIFIER P-1812 OPERATING INSTRUCTIONS PA AMPLIFIER P-1812 Please follow the instructions in this manual to obtain the optimum results from this unit. We also recommend that you keep this manual handy for future reference.

More information

TABLE OF CONTENTS ADJUSTING YOUR LCD MONITOR

TABLE OF CONTENTS ADJUSTING YOUR LCD MONITOR TABLE OF CONTENTS ADJUSTING YOUR LCD MONITOR -------------- 2 General safety precautions. 2 Unpacking your monitor 5 Viewing angle 6 How to open the back cover 6 Connecting your monitor 7 User controls

More information

HCS-3600 / 3602 / 3604 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control

HCS-3600 / 3602 / 3604 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control HCS-3600 / 3602 / 3604 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control 1. INTRODUCTION User Manual This family of efficient, upgraded SMPS with small form factor,

More information

MAC3 Wind Speed Alarm & Controller. Installation Instructions

MAC3 Wind Speed Alarm & Controller. Installation Instructions MAC3 Wind Speed Alarm & Controller Installation Instructions Table of Contents Overview... 3 Installation... 3 Optional Equipment... 10 Dual Sensor Operation... 10 Other Optional Equipment... 10 Operation

More information

Part No. Z , IA Jul OPERATION MANUAL. High Voltage Digitalmeter A

Part No. Z , IA Jul OPERATION MANUAL. High Voltage Digitalmeter A Part No. Z1-109-820, IA001705 Jul. 2016 OPERATION MANUAL High Voltage Digitalmeter 149-10A Use of Operation Manual Please read through and understand this Operation Manual before operating the product.

More information

PRO-1250D CT MID DIN rail three phase four wire energy meter.

PRO-1250D CT MID DIN rail three phase four wire energy meter. PRO-1250D CT MID DIN rail three phase four wire energy meter. 1.1 Safety instructions 1.2 Foreword 1.3 MID certificate 1.4 Performance criteria 1.5 Specifications 1.6 Basic errors 1.7 Description 1.8 Dimensions

More information

T4HD: Installation Supplement R8.1.13

T4HD: Installation Supplement R8.1.13 THD: Installation Supplement R8.. Smartscan Incorporated 08 Eight Mile Road Livonia MI 8 Tel: (8)77-900 Fax: (8) 77-7 Web: www.smartscaninc.com Smartscan Incorporated Livonia, Michigan THD The use of this

More information

PRODUCT MANUAL. Product Description. Manual will Review. Product Features. Main Functions. Waterproof 120V AC DMX-RGB Controller.

PRODUCT MANUAL. Product Description. Manual will Review. Product Features. Main Functions. Waterproof 120V AC DMX-RGB Controller. Product Description Thank you for purchasing Solid Apollo s Waterproof 120V AC DMX to RGB Controller. It is a new standard in DMX to RGB 3 Channel DMX Interfaces. If you currently have a DMX512 controller

More information

4 Connection and interface

4 Connection and interface MDrive 23 Motion Control 4 Connection and Interface 4 Connection and interface EXPOSED SIGNALS! DANGER Hazardous voltage levels may be present if using an open frame power supply to power the product.

More information

TOUCHBOX. iphone I N S T R U C T I O N M A N U A L

TOUCHBOX. iphone I N S T R U C T I O N M A N U A L TOUCHBOX W I R E L E S S C O N T R O L L E R iphone I N S T R U C T I O N M A N U A L Thank you for purchasing TouchBox by ZAETECH. Disclaimer TouchBox is for show and off road use only. It may not be

More information

BNI IOL A027 BNI IOL A027

BNI IOL A027 BNI IOL A027 BNI IOL-771-000-A027 BNI IOL-772-000-A027 IO-Link Version 1.1 Universel IO-Link Interface With undervoltage / broken coil detection User s Guide Inhalt 1 Notes to the user 2 1.1. About this guide 2 1.2.

More information

Smith Meter ETR-1000 Electronic Register

Smith Meter ETR-1000 Electronic Register MANUAL Smith Meter ETR-1000 Electronic Register Operator Reference Manual Bulletin MNTA001 Issue/Rev 0.1 (9/17) Technical Support Contact Information: Field Service Response Center 24/7 Technical Support/Schedule

More information

Two-door Access Controller

Two-door Access Controller Two-door Access Controller Quick Start Guide V1.0.0 Preface Overview This document elaborates on structure, installation, interface and wiring of two-door access controller. Symbol Definition The following

More information

Valve terminal RE-10 with Multi-pin, AS-Interface or bus connection 4 12 valve stations, 300 Nl/min (0.305 Cv)

Valve terminal RE-10 with Multi-pin, AS-Interface or bus connection 4 12 valve stations, 300 Nl/min (0.305 Cv) Type of connection = AS = B1 = B6 Order code RE-10/08-M-1-060 Series Number of stations Multi-pin: 4, 6, 8, 10, 12 Bus versions: 4, 8, 12 Electrical options M-1 = Multi-pin D-Sub plug AS3 = AS-Interface

More information

PRO1 V21.xxx series MID DIN rail single phase two wire energy meter

PRO1 V21.xxx series MID DIN rail single phase two wire energy meter PRO1 V21.xxx series MID DIN rail single phase two wire energy meter PRO1D V21.212 Version 1.1 Note: the picture on the frontpage is a meter from the series of this meter, it might not be exactly the same

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS Wired Remote Controller 7 Day Programmable Ductless Systems KSACN0401AAA (High Wall Models) KSACN0501AAA (Ducted/Cassette Models) INSTALLATION INSTRUCTIONS NOTE: Read the entire instruction manual before

More information

CMC III Universal Sensor

CMC III Universal Sensor CMC III Universal Sensor DK 7030.190 Assembly and operating instructions Foreword Foreword Dear Customer, Thank you for choosing our CMC III universal sensor (referred to hereafter as "universal sensor")!

More information

Manual Control Unit GFC 32

Manual Control Unit GFC 32 Manual Control Unit 1400004_EN/05.2017 Index 1. Main features 3 2. Technical features 3 3. Installation guidelines 4 4. Preliminary checks 5 5. Electrical connections 5 6. Settings 6 7. Remote control

More information

User's Guide. Model W 3-in-1 Switching DC Power Supply

User's Guide. Model W 3-in-1 Switching DC Power Supply User's Guide Model 382260 80W 3-in-1 Switching DC Power Supply Introduction Congratulations on your purchase of the Extech 80W 3-in-1 Switching DC Power Supply. The Model 382260 has three output ranges

More information

Installation Instructions 4291 and 4292 Keypads

Installation Instructions 4291 and 4292 Keypads Installation Instructions 4291 and 4292 Keypads A6851J 02/11 Copyright 2011, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the

More information

User Manual Back-UPS Pro BN 1100/1350/1375/1400/1500 M2 BN 1100/1350/1500 M2-CA

User Manual Back-UPS Pro BN 1100/1350/1375/1400/1500 M2 BN 1100/1350/1500 M2-CA User Manual Back-UPS Pro BN 1100/1350/1375/1400/1500 M2 BN 1100/1350/1500 M2-CA Safety and General Information Inspect the package contents upon receipt. Notify the carrier and dealer if there is any damage.

More information

Vehicle Service Dispensing Systems

Vehicle Service Dispensing Systems Vehicle Service Dispensing Systems Lincoln s LFC Family of Fluid Inventory Control and Management Systems A complete offering of systems to meet the varying needs of vehicle service centers! Each system

More information

Operating instructions. Standstill monitor A / / 2011

Operating instructions. Standstill monitor A / / 2011 Operating instructions Standstill monitor A300 UK 1 2 3 4 5 6 7 8 7390337 / 01 02 / 2011 1 2 3 4 5 6 7 8 switchpoint min max pulse/min power Made in Germany ifm electronic gmbh D 45127 Essen func. I II

More information

INSTALLATION MANUAL For authorized service personnel only.

INSTALLATION MANUAL For authorized service personnel only. AIR CONDITIONER SIMPLE REMOTE CONTROLLER (WIRED TYPE) UTY-RSNUM INSTALLATION MANUAL For authorized service personnel only. English Français Español Contents. SAFETY PRECAUTIONS...2 2. ACCESSORIES...2 3.

More information

USB 2.0 RG port USB m Cat 5e Extender System. User Guide

USB 2.0 RG port USB m Cat 5e Extender System. User Guide USB 2.0 RG2204 4-port USB 2.0 100m Cat 5e Extender System User Guide Thank you for purchasing the USB 2.0 RG2204. Please read this guide thoroughly. This document applies to Part Numbers: 01-00294, 01-00295,

More information

Operation Manual. Concorde 600 Power Supply. *This instrument is intended for laboratory use only.

Operation Manual. Concorde 600 Power Supply. *This instrument is intended for laboratory use only. Concorde 600 Power Supply Operation Manual Cat.no. R10-1001011 *This instrument is intended for laboratory use only http://www.recenttec.com E-mail : support@recenttec.com Version 1.1 Packing List x 1

More information

TS550R SMART CONTROLLER FOR PNEUMATIC VALVES

TS550R SMART CONTROLLER FOR PNEUMATIC VALVES TS550R SMART CONTROLLER FOR PNEUMATIC VALVES User Guide Copyright OK International CONTENTS Page Number 1. Safety 3 2. Symbol Definitions.. 4 3. Specifications... 5 4. Features.. 5 5. To Controll Pneumatic

More information

Preparing for a Docking Drawer Slim Installation To prepare for a successful Docking Drawer Slim installation please ensure that the cable management

Preparing for a Docking Drawer Slim Installation To prepare for a successful Docking Drawer Slim installation please ensure that the cable management Docking Drawer Install Manual Docking Drawer Slim Series Applicable Models: 0290 00031(W) / 24 0290-00030(W) / 21 0290-00047(W) / 18 0230-00004. r6 1/19/2016 CAUTION READ CAREFULLY Failure to follow these

More information

OPERATING INSTRUCTION

OPERATING INSTRUCTION OPERATING INSTRUCTION AUTORANGING MULTIMETER MAX Ω F C 10A MAX every 15 min. COM V SAFETY INFORMATION The following safety information must be observed to insure maximum personal safety during the operation

More information

TS560R SMART CONTROLLER FOR SPRAY VALVES

TS560R SMART CONTROLLER FOR SPRAY VALVES 11. I/O CONFIGURATION AND END OF CYCLE FEEDBACK During a spray cycle, an open collector circuit closes and remains closed while the valve is dispensing. Pin 3 and 4 can be as feedback signal to synchronize

More information

Tesla TI Generator Set Interface

Tesla TI Generator Set Interface Power Anytime, Anywhere Tesla TI2000-440 Generator Set Interface User Manual Built Smart...Proven Tough Tesla Industries, Inc. 101 Centerpoint Blvd. New Castle, DE 19720 (302) 324-8910 Phone (302) 324-8912

More information

LINE BUTTONS LCD SCREEN

LINE BUTTONS LCD SCREEN 4028 7 th Street S.E. Calgary, Alberta T2G-2Y8 Phone: (403) 243-1425 Fax: (403) 243-6577 Toll Free: 1-800-921-ACCU (2228) Email: sales@accuflo.com OPERATING INSTRUCTIONS - DETAILED SECTION ONE General

More information

Zenith DS9000 Dispensing System

Zenith DS9000 Dispensing System Page Date: 04/2009 Zenith DS9000 Dispensing System Installation & Operation Manual Page 2 Table of Content Introduction... 3 Control Specification... 4 Wiring Diagram... 5 Wiring Instructions... 6 Field

More information

Type Quickstart

Type Quickstart Type 8605 Digital Control Electronics for Proportional Valves Digitale Ansteuerelektronik für Proportionalventile Régulateur électronique numérique pour vannes proportionnelles Quickstart Contents 1 Quickstart...

More information

FOR SERVICE TECHNICIAN S USE ONLY

FOR SERVICE TECHNICIAN S USE ONLY Tech Sheet Do not discard DANGER WARNING Electrical Shock Hazard Only authorized technicians should perform diagnostic voltage measurements. After performing voltage measurements, disconnect power before

More information

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016 Operating instructions AS-i SmartLine module AC3200 AC3201 80237876/00 06/2016 Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Warnings used...3 2 Safety instructions...3 2.1 General...3 2.2 Target

More information

Installing and Configuring Rialto Analytic Appliances

Installing and Configuring Rialto Analytic Appliances Installing and Configuring Rialto Analytic Appliances Important Safety Information This manual provides installation and operation information and precautions for the use of this camera. Incorrect installation

More information

VM VM

VM VM 2018 VM-5200-16 VM-5200-32 Operator s Manual The Daugherty Companies, Inc. P.O. Box 306 Warren, IN 46792 Ph. 260-375-2415 - Fax 260-375-3800 www.ag-electronics.com Rev 0418.1 NOTES: 2 Introduction Rev

More information

GV3000/SE Operator Interface Module (OIM) User Guide Version 2.0 M/N 2RK3000

GV3000/SE Operator Interface Module (OIM) User Guide Version 2.0 M/N 2RK3000 GV3000/SE Operator Interface Module (OIM) User Guide Version 2.0 M/N 2RK3000 Instruction Manual D2-3342-2 The information in this manual is subject to change without notice. Throughout this manual, the

More information

Troubleshooting the Digisolver for Allen Bradley SLC-500 Programmable Logic Controllers

Troubleshooting the Digisolver for Allen Bradley SLC-500 Programmable Logic Controllers The Digisolver is a Rotary Sensor which provides the Programmable Logic Controller (PLC) with a 0 to 359 degree value. The unit operates on 24 VDC plus or minus 1.0 VDC and is connected with one of the

More information

BASIC PA AMPLIFIER A-1031 A-1061 A-1121 OPERATING INSTRUCTIONS TABLE OF CONTENTS

BASIC PA AMPLIFIER A-1031 A-1061 A-1121 OPERATING INSTRUCTIONS TABLE OF CONTENTS OPERATING INSTRUCTIONS BASIC PA AMPLIFIER A-1031 A-1061 A-1121 Please follow the instructions in this manual to obtain the optimum results from this unit. We also recommend that you keep this manual handy

More information

LED MOVING HEAD FLEX BEAM K8 RGBW. User Manual. Please read the instruction carefully before use

LED MOVING HEAD FLEX BEAM K8 RGBW. User Manual. Please read the instruction carefully before use LED MOVING HEAD FLEX BEAM K8 RGBW 1 User Manual Please read the instruction carefully before use CONTENTS 1. Safety Instructions... 3 2. Technical Specifications... 4 3. How To Set The Unit... 5 3.1 Front

More information

DRT-301 A/D. User manual. Three phase four wire DIN rail energy meter. (Seven modules) 1.1 Safety instruction. 1.2 Foreword. 1.3 Performance criteria

DRT-301 A/D. User manual. Three phase four wire DIN rail energy meter. (Seven modules) 1.1 Safety instruction. 1.2 Foreword. 1.3 Performance criteria DRT-301 A/D Three phase four wire DIN rail energy meter (Seven modules) 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Structure Diagram 1.7 Dimensions

More information

VLT Line Filter MCC 107 EMC Filter Series VLT Midi Drive FC 280 (K1 K3)

VLT Line Filter MCC 107 EMC Filter Series VLT Midi Drive FC 280 (K1 K3) These instructions provide technical and installation information for the MCC 107 EMC filter series. Only Danfoss qualified personnel is allowed to install this equipment. The personnel must be familiar

More information

Analog Monitor Installation Manual

Analog Monitor Installation Manual Analog Monitor Installation Manual Part Number: 144-23919 Copyright 2011 Magnetek 1. Preface and Safety Magnetek manufactures products used as components in a wide variety of industrial systems and equipment.

More information

Manual Simatek Control Unit GFC 32

Manual Simatek Control Unit GFC 32 Manual Simatek Control Unit GFC 32 Original instructions 1400004_GB Ver. 2014.01.09 Index 1. Main features 3 2. Technical features 3 3. Installation guidelines 4 4. Preliminary checks 5 5. Electrical connections

More information

I/O module (Expansion module)

I/O module (Expansion module) I/O module (Expansion module) Variomat Variomat Giga Reflexomat Servitec V2.00 02.02.2015 GB Operating manual Original operating manual English I/O module (Expansion module) Contents 02.02.2015 Contents

More information

PumpDrive DPM. Installation and Operating Instructions Dual Pump Module (DPM) /4--10

PumpDrive DPM. Installation and Operating Instructions Dual Pump Module (DPM) /4--10 4070.83/4--10 PumpDrive DPM Installation and Operating Instructions Dual Pump Module (DPM) These installation and operating instructions are not valid on their own. They must always be applied in conjunction

More information

8000 Series: Installation Supplement R2-1-12

8000 Series: Installation Supplement R2-1-12 8000 Series: Installation Supplement R2-1-12 Smartscan Incorporated, 33083 Eight Mile Road, Livonia MI 48152 Tel: (248) 477-2900 Fax: (248) 477-7453 Web: www.smartscaninc.com SMARTSCAN INCORPORATED Livonia,

More information

MicroTech III Applied Terminal Systems BACnet MS/TP Communication Module

MicroTech III Applied Terminal Systems BACnet MS/TP Communication Module Installation and Maintenance Manual IM 928-2 Group: Controls Part Number: 669207702 Date: March 2011 Supersedes: IM 928-1 MicroTech III Applied Terminal Systems BACnet MS/TP Communication Module NOTICE

More information

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx Preface Obtaining Documentation and Submitting a Service Request, page xvii Safety s, page xvii Safety Guidelines, page xx Obtaining Documentation and Submitting a Service Request For information on obtaining

More information

Fluid Inventory Control

Fluid Inventory Control Fluid Inventory Control Fluid Inventory Control Automotive Commercial Industrial Fluid Inventory Control Product Selection Matrix Fluid Inventory Control Product Selection Matrix Director Jr. Director

More information

Series B9 and C9 Electronic Metering Pumps. Instruction Manual. Manual No : 1796 Rev. : D Rev. Date : 11/2015

Series B9 and C9 Electronic Metering Pumps. Instruction Manual. Manual No : 1796 Rev. : D Rev. Date : 11/2015 Series B9 and C9 Electronic Metering Pumps Manual No : 1796 Rev. : D Rev. Date : 11/2015 sales@novatech-usa.com www.novatech-usa.com Tel: (866) 433-6682 Fax: (866) 433-6684 Tel: (281) 359-8538 Fax: (281)

More information

DIGITAL INPUT/OUTPUT RELAY INTERFACE BMS-IFDD01E

DIGITAL INPUT/OUTPUT RELAY INTERFACE BMS-IFDD01E INSTALLATION MANUAL DIGITAL INPUT/OUTPUT RELAY INTERFACE BMS-IFDD01E Thank you very much for purchasing this TOSHIBA Digital Input/Output Relay Interface. Please read this manual carefully beforehand for

More information

KP2000E/EM Series Style Keypad

KP2000E/EM Series Style Keypad 23852973 KP2000E/EM Series Style Keypad Installation and Programming Instructions Models KP2000EXX and KP2000EMXX Specifications Parameter Voltage Requirements Keypad Current Requirements (Max) Relay Contact

More information

SAFETY WARNINGS AND GUIDELINES

SAFETY WARNINGS AND GUIDELINES 1 SAFETY WARNINGS AND GUIDELINES Please read this entire manual before using this device, paying extra attention to these safety warnings and guidelines. Please keep this manual in a safe place for future

More information

EPS Power Supply

EPS Power Supply EPS - 600 Power Supply Installation and Operation Manual Version 1.0 *This instrument is intended for laboratory use only Index A. Important Notice ----------------------------------------------------------------

More information