HP D2600/D2700 Disk Enclosure I/O Module Firmware 0147 Release Notes
|
|
- Kristian Holland
- 6 years ago
- Views:
Transcription
1 HP D2600/D2700 Disk Enclosure I/O Module Firmware 0147 Release Notes HP Part Number: Published: October 2012 Edition: 8
2 Copyright 2009, 2012 Hewlett-Packard Development Company, L.P.
3 nl Version: 0147 Description The I/O module firmware included in this package corrects a fan speed issue found during qualification testing. Update recommendation In server-attached environments: Recommended (See Prerequisites for conditions.) In enclosure-attached environments: Recommended Supersedes 0146 Product models HP D2600 6Gb SAS Disk Enclosure (D2600), Large Form Factor (LFF) model HP D2700 6Gb SAS Disk Enclosure (D2700), Small Form Factor (SFF) model Supported devices In direct-connect environments (D2600/D2700): HP Smart Array P212 controller HP Smart Array P411 controller HP Smart Array P812 controller HP Smart Array P222 controller HP Smart Array P421 controller HP Smart Array P822 controller In controller-enclosure-connect environments (D2700): HP P2000 G3 Fibre Channel MSA controller enclosure (P2000 G3 FC MSA) HP P2000 G3 Fibre Channel/iSCSI Combo MSA controller enclosure (P2000 G3 FC/iSCSI MSA) HP P2000 G3 SAS MSA controller enclosure (P2000 G3 SAS MSA) HP P2000 G3 10GbE iscsi MSA Array System controller enclosure (P2000 G3 10GbE iscsi MSA) HP P2000 G3 1GbE iscsi MSA Array System controller enclosure (P2000 G3 1GbE iscsi MSA) Supported operating systems Operating system Microsoft Windows Linux Version Microsoft Windows Server 2003 W32 All Editions (Including R2 & Base Edition) Microsoft Windows Server 2003 x64 All Editions (Including R2 & Base Edition) Microsoft Windows Server 2008 W32 All Editions Microsoft Windows Server 2008 x64 All Editions (Including R2 & Base Edition) Red Hat Enterprise Linux 4 x86, AMD64/EM64T Red Hat Enterprise Linux 5 x86, AMD64/EM64T Red Hat Enterprise Linux 6 x86, AMD64/EM64T Description 3
4 Operating system Version SUSE LINUX Enterprise Server 10 x86, AMD64/EM64T SUSE LINUX Enterprise Server 11 x86, AMD64/EM64T NOTE: Support for additional operating systems may be approved after initial release of this firmware. For up-to-date, detailed operating system support information and known restrictions, see one of the following: HP Storage Single Point Of Connectivity Knowledge (SPOCK) website ( HP D2000 QuickSpecs, available on the D2000 website ( Enhancements and fixes Prerequisites The following items was fixed in firmware 0147 Fixed an issue found during manufacturing testing where, after hot plugging an I/O module, the enclosure fan speed did not return to the dual I/O module configuration fan speed. The following items were added or fixed in firmware 0146: Fixed a reporting issue in which a power supply was incorrectly reported as failed by some management utilities. Added speed negotiation to allow 6 Gb/s SATA drives to function at 3 Gb/s. Server-attach environments installing D2600/D2700 I/O module firmware 0070 or later must update Smart Array controller firmware to v3.50 or higher before installing new firmware on the D2600/D2700 disk enclosure. Installation instructions Included in this section: Installation notes and best practices (page 4) Installation instructions for server-connect environments (page 5) Installation instructions for controller enclosure connect environments (page 6) Installation notes and best practices When planning a firmware update, schedule an appropriate time to perform the update. Firmware updates must be performed during a system maintenance window, with all I/O to the system halted. Before installing new firmware, review system requirements, enhancements list, fixes list, and other information in the firmware release notes, device QuickSpecs, and updated user documentation. Before installing new firmware, ensure that the system is stable and is not being reconfigured or changed in any way. If changes are in progress, monitor them and wait until they are completed before proceeding with the upgrade. Before installing new firmware, HP recommends creating a full backup of all data stored on the enclosure. After the installation process, verify system status in the software tools and confirm that the new firmware version is displayed as running on the enclosure. 4 Enhancements and fixes
5 Installation instructions for server-connect environments The following methods can be used to install new firmware in server-connect environments, such as when the D2600 or D2700 disk enclosure is connected to a Smart Array controller installed in the server: Installing firmware using Smart Components in Windows environments (page 5) Installing firmware using Smart Components in Linux environments (page 5) Special installation procedures for single-domain environments (page 5) Installing firmware using Smart Components in Windows environments Firmware is embedded in the downloaded file, which is a self-extracting, executable module. Execution procedures differ by operating system. IMPORTANT: Firmware updates must be performed during a system maintenance window; halt all I/O to the system. NOTE: In dual-domain configurations, both I/O modules of the target disk enclosure and any cascaded disk enclosures are automatically updated during the firmware installation process. This is a self-extracting executable module. Execute this module from the command line console or the Windows graphical user interface. 1. Save the downloaded file in a temporary directory. 2. From the temporary directory, invoke the Smart Component in the command line console or double-click the CPxxxxxx.exe file. (CPxxxxxx.exe represents the downloaded file.) 3. Follow the on-screen instructions. Installing firmware using Smart Components in Linux environments This is a self-extracting executable module. This module operates only from the Linux command line. IMPORTANT: Firmware updates must be performed during a system maintenance window; halt all I/O to the system. NOTE: In dual-domain configurations, both I/O modules of the target disk enclosure and any cascaded disk enclosures are automatically updated during the firmware installation process. 1. Save the downloaded file in a temporary directory. 2. Open a Linux command console. 3. From the temporary directory, enable execute access to this module by entering: chmod +x CPxxxxxx.scexe (Where CPxxxxxx.scexe represents the downloaded file.) 4. Execute the Smart Component by entering:./cpxxxxxx.scexe 5. Follow the on-screen instructions. Special installation procedures for single-domain environments In a single domain configuration, I/O module A (top module) is connected to a host and I/O module B (bottom module) is unused. Even though the bottom I/O module is unused, both modules must have the same firmware version installed. Do the following to make sure that both I/O modules are updated: Installation instructions 5
6 1. Flash I/O module A of the first and all cascaded disk enclosures using the firmware upgrade executable. NOTE: When disk enclosures are cascaded, I/O module A of one enclosure is connected to I/O module A of the subsequent enclosure. During a firmware update, I/O module A in the cascaded disk enclosures is automatically updated. 2. After I/O module A is flashed successfully in the disk enclosures, shut down and turn off the server. 3. Remove A/C power to the first and all cascaded disk enclosures. 4. Label all cables connected to I/O module A of the first and all cascaded disk enclosures and then disconnect all cables from the I/O modules. 5. Swap the positions of the I/O modules in the enclosure. 6. Reconnect the cables to the top I/O module (it used to be the bottom I/O module) in the enclosure, using the labels to ensure that all cabling is connected properly, in the same configuration as before. 7. Turn on the storage enclosures and wait for the storage enclosures to complete their startup routines. 8. Turn on the server. 9. After the server startup procedure is complete, flash the top I/O module (the new I/O module A) of the first and all cascaded disk enclosures using the firmware upgrade executable. 10. After the I/O module is flashed successfully in the disk enclosures, power cycle the server to resume normal operation. Installation instructions for controller enclosure connect environments The following methods can be used to install new firmware in controller enclosure-connect environments, such as when the D2700 disk enclosure is connected to a controller enclosure, which in turn is connected to a server or network: Installing firmware using Smart Components in Windows environments (page 6) Installing firmware using Smart Components in Linux environments (page 7) Installing firmware using the Storage Management Utility (SMU) (page 7) Installing firmware using FTP (page 8) Installing firmware using Smart Components in Windows environments This is a self-extracting executable module. You can execute this module from the Windows graphical user interface (GUI) or the command line console (CLI). GUI option 1. Save the downloaded Smart Component package in a temporary directory. 2. Using Windows Explorer, navigate to the temporary directory containing the download and double click the executable file. 3. When prompted: Check Flash using network. Enter target information of the disk enclosure, including its IP address and a username and password for an account with management access rights. Follow the remaining onscreen instructions. 6 Installation instructions
7 nl CLI option 1. Execute the Smart Component by entering: CPxxxxxxx.exe /target <ip_address> /user <username> /passwd <password> /s Where: CPxxxxxxx.exe is the name of the downloaded firmware file ip_address is the management IP address of the array controller username is the username account with management rights password is the password for username 2. When prompted for logon information, enter credentials for an account with management access rights. NOTE: Instead of command line parameters, you can use the following DOS environment variables: oa_address to set this variable for the IP address of controller oa_username to set this variable for the username of controller oa_password to set this variable for the password of controller Installing firmware using Smart Components in Linux environments 1. Save the downloaded Smart Component package in a temporary directory. 2. Open a Linux command console. 3. From the temporary directory containing the downloaded file, enable execute access to this model by entering: chmod +x CPxxxxxx.scexe (Where CPxxxxxx.scexe represents the downloaded firmware file.) 4. Execute the Smart Component by entering:./cpxxxxxx.scexe --target <ip_address> --user <username> --passwd <password> If the user name or password contains an exclamation mark (!), enclose the string in single quotes or enter a backslash (\) before the exclamation point. For example, '!manage' or \!manage. 5. Follow the onscreen instructions. When prompted for logon information, enter credentials for an account with management access rights. Installing firmware using the Storage Management Utility (SMU) WARNING! Do not perform a power cycle or controller restart during a firmware update. If the update is interrupted or there is a power failure, the module might become inoperative. If this occurs, contact technical support. The module might need to be returned to the factory for reprogramming. 1. Save the downloaded firmware package in a temporary directory. 2. If you are using a Smart Component, extract the contents of the Smart Component using one of the following methods: In Windows environments, click Extract on the first screen of the Smart Component. In Linux environments, enter./cpxxxxxx.scexe --unpack=<folder name> (Where CPxxxxxx.scexe represents the downloaded firmware file.) 3. If the system has a single controller, stop I/O to the vdisks before starting the firmware update. Installation instructions 7
8 nl nl 4. Log in to the SMU and, from the Configuration View panel, right-click the system and select Tools > Update Firmware. A table displays currently installed firmware versions. 5. Click Browse, navigate to the temporary directory containing the downloaded firmware file, and select the firmware file to install. 6. Click Install Controller-Module Firmware File. It takes approximately 10 minutes for the firmware to load and for the automatic restart to complete on the controller to which you are connected. Wait for the progress messages to specify that the update has completed. If Partner Firmware Update is enabled, allow an additional 20 minutes for the partner controller to be updated. 7. In the SMU display, verify that the proper firmware version is displayed for each module. Installing firmware using FTP 1. Save the downloaded firmware package in a temporary directory. 2. If you are using a Smart Component, extract the contents of the Smart Component using one of the following methods: In Windows environments, click Extract on the first screen of the Smart Component. In Linux environments, enter./cpxxxxxx.scexe --unpack=<folder name> (Where CPxxxxxx.scexe represents the downloaded firmware file.) 3. Prepare to use FTP: a. Determine the network-port IP addresses of the system controllers. b. Verify that the system FTP service is enabled. c. Verify that the user you will log in as has permission to use the FTP interface and has manage access rights. d. Obtain the I/O module addresses to be loaded in the format channel-id>:<emp-number (for example 0:15 or 1:31). TIP: For a D2700 connected to a P2000 G3 array controller enclosure, the EMP addresses are displayed in the SMU by clicking each enclosure in the Configuration View. The needed data is displayed in the fields labeled EMP A Bus ID, EMP B Bus ID, EMP A Target ID, EMP B Target ID, EMP A Revision, and EMP B Revision. (The terms bus and channel are equivalent.) To obtain the EMP addresses using the CLI, enter the show enclosures command. The needed data is displayed in the columns labeled EMP A CH:ID Rev and EMP B CH:ID Rev. There are typically two I/O modules in each drive enclosure. 4. Open a command prompt (Windows) or a terminal window (UNIX), navigate to the temporary directory containing the firmware file to load, and install the firmware as follows: a. Enter ftp <controller-network-address> b. Log in as an FTP user. In P2000 environments: user = ftp password =!ftp In MSA2000 environments: user = ftp password = flash c. Install the firmware by entering: put <firmware-file> encl:<channel-id>:<emp-number> flash (Where firmware-file represents the downloaded firmware file.) 5. If needed, repeat these steps to load the firmware on additional modules. 6. Quit the FTP session. 7. In the SMU display, verify that the proper firmware version is displayed for each module. 8 Installation instructions
9 Supersedes history Firmware Version Release date October 2012 August 2012 June 2011 October 2010 September 2010 May 2010 November 2009 June 2009 Effective date October 2012 Supersedes history 9
HPE D2600/D2700 Disk Enclosure I/O Module Firmware 0149 Release Notes
HPE D2600/D2700 Disk Enclosure I/O Module Firmware 0149 Release Notes Part Number: 504224-011R Published: November 2015 Edition: 12 Copyright 2009, 2015 Hewlett Packard Enterprise Development LP The information
More informationHP Scalable File Share G3 MSA2000fc How To
HP Scalable File Share G3 MSA2000fc How To Abstract This document provides best practices for critical or sensitive MSA2000fc storage operations and configuration information specifically for the HP SFS
More informationUpgrading R/Evolution Storage Systems
Upgrading R/Evolution Storage Systems This guide describes considerations and procedures for upgrading the following R/Evolution storage systems: 2000 Series to 2002 Series storage systems 2000 Series
More informationHPE BladeSystem c-class Virtual Connect Support Utility Version Release Notes
HPE BladeSystem c-class Virtual Connect Support Utility Version 1.12.0 Release Notes Abstract This document provides release information for the HPE BladeSystem c-class Virtual Connect Support Utility
More informationHP StorageWorks SmartStart EVA Storage 3.2 Release Notes
HP StorageWorks SmartStart EVA Storage 3.2 Release Notes Part Number: T5505-96034 Second edition: June 2010 Legal and notice information Copyright 2010 Hewlett-Packard Development Company, L.P. Microsoft
More informationHP P6300/P6500 EVA Fibre Channel Controller Replacement Instructions
HP P6300/P6500 EVA Fibre Channel Controller Replacement Instructions About this document For the latest documentation, go to http:// www.hp.com/support/manuals, and select your product. The information
More informationHP BladeSystem c-class Virtual Connect Support Utility Version Release Notes
HP BladeSystem c-class Virtual Connect Support Utility Version 1.9.1 Release Notes Abstract This document provides release information for the HP BladeSystem c-class Virtual Connect Support Utility Version
More informationHP-J051. HP - HP-J051 Installing HP StorageWorks Solutions
HP - HP-J051 Installing HP StorageWorks Solutions 1 QUESTION: 1 The HP P2000 G3 FC Storage Array supports both the MSA70 and D2700 disk enclosures. When connecting these enclosures to the P2000 G3 FC controller,
More informationHPE 3PAR OS MU3 Patch 97 Upgrade Instructions
HPE 3PAR OS 3.2.2 MU3 Patch 97 Upgrade Instructions Abstract This upgrade instructions document is for installing Patch 97 on the HPE 3PAR Operating System Software. This document is for Hewlett Packard
More informationHP Insight Control for VMware vcenter Server Release Notes 7.2.1
HP Insight Control for VMware vcenter Server Release Notes 7.2.1 HP Part Number: 678314-006a Published: June 2013 Edition: 2 Copyright 2013 Hewlett-Packard Development Company, L.P. Acknowledgements Microsoft
More informationEnd of Life Announcement for HP EVA P6350 and P6550 Storage
September 12, 2013 End of Life Announcement for HP EVA P6350 and P6550 Storage Dear Valued HP EVA Storage Customer: HP appreciates and values your business. We are writing to inform you of an upcoming
More informationHP Intelligent Provisioning 2.20 Release Notes
HP Intelligent Provisioning 2.20 Release Notes HP Part Number: 794361-004b Published: July 2015 Edition: 3 Copyright 2012, 2015 Hewlett-Packard Development Company, L.P. Version: 2.20 Description Supersedes
More informationBL8x0c i2: Overview, Setup, Troubleshooting, and Various Methods to Install OpenVMS
OpenVMS Technical Journal V15 BL8x0c i2: Overview, Setup, Troubleshooting, and Various Methods to Install OpenVMS Aditya B S and Srinivas Pinnika BL8x0c i2: Overview, Setup, Troubleshooting, and Various
More informationMSA1500csReleaseNotes8_ txt MSA1500cs ReleaseNotes. hp StorageWorks Modular Smart Array 1500 cs Release Notes. Third Edition (February 2005)
MSA1500cs ReleaseNotes hp StorageWorks Modular Smart Array 1500 cs Release Notes Third Edition (February 2005) Publication of the third edition of this document coincides with the release of MSA1500 cs
More informationHP MSA 2300 Series Configuration Guide
HP MSA 2300 Series Configuration Guide 1. Logon to console 2. Configure system settings 3. Create Vdisks 4. Create Volumes 5. Assign volumes to Hosts 6. Create Global Spares 7. Rename Host Login to console:
More informationHP LeftHand P4500 and P GbE to 10GbE migration instructions
HP LeftHand P4500 and P4300 1GbE to 10GbE migration instructions Part number: AT022-96003 edition: August 2009 Legal and notice information Copyright 2009 Hewlett-Packard Development Company, L.P. Confidential
More informationDtS Data Migration to the MSA1000
White Paper September 2002 Document Number Prepared by: Network Storage Solutions Hewlett Packard Company Contents Migrating Data from Smart Array controllers and RA4100 controllers...3 Installation Notes
More informationHP Supporting the HP ProLiant Storage Server Product Family.
HP HP0-698 Supporting the HP ProLiant Storage Server Product Family https://killexams.com/pass4sure/exam-detail/hp0-698 QUESTION: 1 What does Volume Shadow Copy provide?. A. backup to disks B. LUN duplication
More informationMULTI FACTOR AUTHENTICATION USING THE NETOP PORTAL. 31 January 2017
MULTI FACTOR AUTHENTICATION USING THE NETOP PORTAL 31 January 2017 Contents 1 Introduction... 2 1.1 Prerequisite for configuring the multi-factor authentication:... 2 1.1.1 On the Guest side... 2 1.1.2
More informationHPE MSA 2042 Storage. Data sheet
HPE MSA 2042 Storage HPE MSA 2042 Storage offers an entry storage platform with built-in hybrid flash for application acceleration and high performance. It is ideal for performance-hungry applications
More informationQuickSpecs. Models SATA RAID Controller HP 6-Port SATA RAID Controller B21. HP 6-Port SATA RAID Controller. Overview.
Overview HP 6 Port SATA RAID controller provides customers with new levels of fault tolerance for low cost storage solutions using SATA hard drive technologies. Models SATA RAID Controller 372953-B21 DA
More informationConfiguring the MSA1000 for Linux or NetWare Environments
White Paper September 2002 Prepared by: Network Storage Solutions Hewlett Packard Company Contents Benefits of the new firmware for the MSA1000...1 Prerequisites...3 Firmware Upgrades:...3 Environmental
More informationHP P2000 G3 MSA System Event Descriptions Reference Guide
HP P2000 G3 MSA System Event Descriptions Reference Guide Part number: 591224-006 First edition: February 2013 Legal and notice information Copyright 2013 Hewlett-Packard Development Company, L.P. Confidential
More informationQuickSpecs. HPE SAS Hard Drives
Overview Serial Attached SCSI (SAS) provides a superior storage solution. With some storage requirements escalating and others becoming more complex, factors such as flexibility, performance, increased
More informationHPE P2000 G3 Troubleshooting Guide
HPE P2000 G3 Troubleshooting Guide Part Number: 869944-001 Published: July 2016 Edition: 1 Contents 1 Troubleshooting HPE P2000 G3...3 Events and LEDs...3 Event Monitoring...3 Events sent as Indications
More informationHPE Direct-Connect External SAS Storage for HPE BladeSystem Solutions Deployment Guide
HPE Direct-Connect External SAS Storage for HPE BladeSystem Solutions Deployment Guide This document provides device overview information, installation best practices and procedural overview, and illustrated
More informationQuickSpecs. HPE MSA P2000 G3 Modular Smart Array Systems. HPE MSA P2000 G3 Modular Smart Array System. Overview
Overview s HPE's MSA P2000 Family of storage arrays features P2000 G3 arrays with the latest 8 GB Fibre Channel, 6 GB SAS, 10GbE iscsi connected models, and an iscsi model with four 1 GB iscsi ports per
More informationDell Storage Center OS Version 7 Software Update Guide
Dell Storage Center OS Version 7 Software Update Guide Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates
More informationSetting Up the Dell DR Series System as an NFS Target on Amanda Enterprise 3.3.5
Setting Up the Dell DR Series System as an NFS Target on Amanda Enterprise 3.3.5 Dell Engineering September 2015 A Dell Technical White Paper Revisions Date June 2015 September 2015 Description Initial
More informationSystem information update for system board replacement events
System information update for system board replacement events Standard Operating Procedure (SOP) When you replace the system board on the HP Pro Tablet 608 G1, the system s EEPROM is not able to detect
More informationSimplifying Blade Server Update with Dell Repository Manager
Simplifying Blade Server Update with Dell Repository Manager Dell Engineering December 2015 A Dell Technical White Paper Revisions Date December 2015 Description Initial release THIS WHITE PAPER IS FOR
More informationGuidelines for using Internet Information Server with HP StorageWorks Storage Mirroring
HP StorageWorks Guidelines for using Internet Information Server with HP StorageWorks Storage Mirroring Application Note doc-number Part number: T2558-96338 First edition: June 2009 Legal and notice information
More informationQuickSpecs. What's New. Models. HP SATA Hard Drives. Overview
Overview HP SATA drives are designed for the reliability and larger capacities demanded by today's entry server and external storage environments. HP SATA Midline drives are designed with economical reliability
More informationHP Integrity Servers and HP 9000 Servers Firmware Update Options
HP Integrity Servers and HP 9000 Servers Firmware Update Options HP Part Number: 5900-2655 Published: March 2013 Edition: 4 Copyright 2010, 2013 Hewlett-Packard Development Company, L.P The information
More informationStorage Manager 2018 R1. Installation Guide
Storage Manager 2018 R1 Installation Guide Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates either
More informationIOmark- VM. HP MSA P2000 Test Report: VM a Test Report Date: 4, March
IOmark- VM HP MSA P2000 Test Report: VM- 140304-2a Test Report Date: 4, March 2014 Copyright 2010-2014 Evaluator Group, Inc. All rights reserved. IOmark- VM, IOmark- VDI, VDI- IOmark, and IOmark are trademarks
More informationHP Direct-Connect External SAS Storage for HP BladeSystem Solutions Deployment Guide
HP Direct-Connect External SAS Storage for HP BladeSystem Solutions Deployment Guide Part number: 510464 003 Third edition: November 2009 Legal and notice information Copyright 2008-2009 Hewlett-Packard
More informationSCO Forum. Aug. 7, Walt Keyser
SCO Forum Aug. 7, Walt Keyser Hewlett Packard Development Company, L.P. The information contained herein is subject to change without notice Agenda Portfolio Transition to serial technology SmartStart
More informationQuickSpecs. What's New HP 120GB 1.5Gb/s SATA 5400 rpm SFF HDD. HP Serial-ATA (SATA) Hard Drive Option Kits. Overview
Overview HP offers a variety of tested, HP-qualified, SMART* capable, SATA Hard Drives offering data integrity and availability in hotpluggable models. HP 3.5" and Small Form Factor (2.5") SATA drives
More informationHP StorageWorks Enterprise Virtual Array 4400 to 6400/8400 upgrade assessment
HP StorageWorks Enterprise Virtual Array 4400 to 6400/8400 upgrade assessment Part number: 5697-8185 First edition: June 2009 Legal and notice information Copyright 2009 Hewlett-Packard Development Company,
More informationHPE ProLiant Gen9 Troubleshooting Guide
HPE ProLiant Gen9 Troubleshooting Guide Volume II: Error Messages Abstract This guide provides a list of error messages associated with HPE ProLiant servers, Integrated Lights-Out, Smart Array storage,
More informationHP LeftHand P4000 Virtual SAN Appliance in an HP BladeSystem environment solution guide
HP LeftHand P4000 Virtual SAN Appliance in an HP BladeSystem environment solution guide AT459-96002 Part number: AT459-96002 First edition: April 2009 Legal and notice information Copyright 2009 Hewlett-Packard
More informationHP EVA Cluster Extension Software Installation Guide
HP EVA Cluster Extension Software Installation Guide Abstract This guide contains detailed instructions for installing and removing HP EVA Cluster Extension Software in Windows and Linux environments.
More informationQuickSpecs. Models. HP Smart Array P400i Controller. Overview
Overview The HP Smart Array P400 Serial Attached SCSI (SAS) controller (SA-P400) provides new levels of performance and reliability for HP servers, through its support of the latest SCSI technology and
More informationSetting Up the DR Series System as an NFS Target on Amanda Enterprise 3.3.5
Setting Up the DR Series System as an NFS Target on Amanda Enterprise 3.3.5 Dell Engineering November 2016 A Quest Technical White Paper Revisions Date June 2015 November 2016 Description Initial release
More informationQuickSpecs. HP SAS Hard Drives. What's New
HP s Overview HP s Serial Attached SCSI () provides a superior storage solution. With some storage requirements escalating and others becoming more complex, factors such as flexibility, performance, increased
More informationMSA Event Descriptions Reference Guide
MSA Event Descriptions Reference Guide Abstract This guide is for reference by storage administrators to help troubleshoot storage-system issues. It describes event messages that may be reported during
More informationSystem Manager Unit (SMU) Hardware Reference
System Manager Unit (SMU) Hardware Reference MK-92HNAS065-02 Notices and Disclaimer Copyright 2015 Hitachi Data Systems Corporation. All rights reserved. The performance data contained herein was obtained
More informationQuickSpecs. What's New. Models. HP SATA Hard Drives. Overview. HP 6G SATA SmartDrive Carriers
Overview HP SATA drives are designed for the reliability and larger capacities demanded by today's entry server and external storage environments. HP SATA Midline drives are designed with economical reliability
More informationQuickSpecs. HPE MSA P2000 G3 Modular Smart Array Systems. Overview
Overview HPE's MSA P2000 Family of storage arrays features P2000 G3 arrays with the latest 8 GB Fibre Channel, 6 GB SAS, 10GbE iscsi connected models, and an iscsi model with four 1 GB iscsi ports per
More informationHPE StoreVirtual OS v13.5 Release Notes
HPE StoreVirtual OS v13.5 Release Notes Part Number: 865552-006 Published: May 2017 Edition: 2 Contents Release notes...4 Description... 4 Platforms supported for this release... 4 Update recommendation...4
More informationHP Smart Update Manager User Guide
HP Smart Update Manager User Guide Abstract This guide is intended for individuals familiar with the configuration and operation of Microsoft Windows, Windows Server, Linux, smart components, and deployment
More informationHP D6000 Disk Enclosure Direct Connect Cabling Guide
HP D6000 Disk Enclosure Direct Connect Cabling Guide Abstract This document provides cabling examples for when an HP D6000 Disk Enclosure is connected directly to a server. Part Number: 682251-001 September
More informationHP P6000 Cluster Extension Software Installation Guide
HP P6000 Cluster Extension Software Installation Guide This guide contains detailed instructions for installing and removing HP P6000 Cluster Extension Software in Windows and Linux environments. The intended
More informationHP ProLiant blade planning and deployment
HP ProLiant blade planning and deployment Chris Powell CSG Products, Services, and Solutions Training Hewlett-Packard 2004 Hewlett-Packard Development Company, L.P. The information contained herein is
More informationHewlett Packard Enterprise StoreOnce 3100, 3500 and 5100 System Installation and Configuration Guide
Hewlett Packard Enterprise StoreOnce 3100, 3500 and 5100 System Installation and Configuration Guide Abstract This guide is for HPE StoreOnce System Administrators. It assumes that the user has followed
More informationHow to Connect the MediCap USB200 or USB170 to a Network
How to Connect the MediCap USB200 or USB170 to a Network You can connect the MediCap USB200 or USB170 1 to a network by using an adapter which is available from MediCapture. Making the connection requires
More informationQuickSpecs. HP SAS Hard Drives. Overview
Overview Serial Attached SCSI (SAS) provides a superior storage solution. With some storage requirements escalating and others becoming more complex, factors such as flexibility, performance, increased
More informationHP ProLiant Firmware Maintenance CD User Guide
HP ProLiant Firmware Maintenance CD User Guide Part Number 447788-007 February 2009 (Seventh Edition) Copyright 2007, 2009 Hewlett-Packard Development Company, L.P. The information contained herein is
More informationNOTE: For additional information regarding the different features of SATA Entry drives please visit the SATA hard drive website:
QuickSpecs Overview HP SATA drives are designed for the reliability and larger capacities demanded by today's entry server and external storage environments. The SATA portfolio is categorized into two
More informationFirmware Update Guide
Firmware Update Guide Micron RealSSD C300 Firmware Revision 0007 Boot from CD update guide (Update from Rev 0006 to Rev 0007) Introduction This document describes the process of updating the firmware on
More informationHPE StoreVirtual Storage Application Aware Snapshot Manager Deployment Guide
HPE StoreVirtual Storage Application Aware Snapshot Manager Deployment Guide Abstract This guide contains instructions for installing and deploying the StoreVirtual Application Aware Snapshot Manager to
More informationRAID-01 (ciss) B Mass Storage Driver Release Notes
RAID-01 (ciss) B.11.31.1705 Mass Storage Driver Release Notes HP-UX 11i v3 Abstract This document contains specific information that is intended for users of this HPE product. Part Number: Published:
More informationHP StorageWorks EVA4400 iscsi Connectivity Option (mpx100b) 5.0. Release Notes
HP StorageWorks EVA4400 iscsi Connectivity Option (mpx100b) 5.0 Release Notes Part Number: 5697-0512 Ninth edition: June 2010 Legal and notice information Copyright 2007-2010 Hewlett-Packard Development
More informationConfiguring Host Router and Cisco Analog Video Gateway Module Interfaces
Configuring Host Router and Cisco Analog Video Gateway Module Interfaces Last Updated: August 17, 2009 To configure the Cisco Analog Video Gateway network module after it is installed in your host Cisco
More informationQuickSpecs. What's New 300GB 6G SAS 15K rpm SFF (2.5in) Enterprise Hard Drive. HP SAS Enterprise and SAS Midline Hard Drives.
Overview Serial Attached SCSI (SAS) provides a superior storage solution. With some storage requirements escalating and others becoming more complex, factors such as flexibility, performance, increased
More informationStoreOnce 6500 (88TB) System Capacity Expansion Guide
StoreOnce 6500 (88TB) System Capacity Expansion Guide Abstract This document explains how to install the StoreOnce 6500 System Capacity Expansion Kit, apply the new license, and add the new storage to
More informationIBM Tivoli Storage Manager. Blueprint and Server Automated Configuration for Linux x86 Version 2 Release 3 IBM
IBM Tivoli Storage Manager Blueprint and Server Automated Configuration for Linux x86 Version 2 Release 3 IBM Note: Before you use this information and the product it supports, read the information in
More informationAgilent OpenLAB Chromatography Data System (CDS)
Agilent OpenLAB Chromatography Data System (CDS) ChemStation Edition AIC (M8304AA) Setup Guide Agilent Technologies Notices Agilent Technologies, Inc. 2010-2014, 2015 No part of this manual may be reproduced
More informationUpgrading Earlier Release Version Servers for Cisco UCS Manager Integration
Upgrading Earlier Release Version s for Cisco UCS Manager Integration This chapter includes the following sections: Required Items for Upgrade, page 1 Upgrading the C-Series Firmware, page 2 Updating Cisco
More informationHP ilo 3 Release Notes
HP ilo 3 Release Notes 1.70 HP Part Number: 616296-401 Published: February 2014 Edition: 1 Copyright 2014 Hewlett-Packard Development Company, L.P Confidential computer software. Valid license from HP
More informationHP OneView for VMware vcenter User Guide
HP OneView for VMware vcenter User Guide Abstract This document contains detailed instructions for configuring and using HP OneView for VMware vcenter (formerly HP Insight Control for VMware vcenter Server).
More informationDell OpenManage Connection for Tivoli Enterprise Console Version 3.5. User s Guide. support.dell.com
Dell OpenManage Connection for Tivoli Enterprise Console Version 3.5 User s Guide www.dell.com support.dell.com Notes and Notices NOTE: A NOTE indicates important information that helps you make better
More informationQuickSpecs. HP MSA P2000 G3 Modular Smart Array System. Overview
Overview Hewlett Packard's MSA P2000 Family of storage arrays features P2000 G3 arrays with the latest 8 Gb Fibre Channel, 6 Gb SAS, 10GbE iscsi connected models, and an iscsi model with four 1 Gb iscsi
More informationHPE MSA 2050 and MSA 2052 Storage VL100P001 Firmware Release Notes
HPE MSA 2050 and MSA 2052 Storage VL100P001 Firmware Release Notes Abstract This package delivers firmware for the HPE MSA 2050 and MSA 2052 Storage systems. Part Number: Q1J79-62019 Published: August
More informationPeplink SD Switch User Manual. Published on October 25th, 2018
Peplink SD Switch User Manual Published on October 25th, 2018 1 Table of Contents Switch Layout 4 Specifications 5 Hardware Overview 6 Quick Start Functions 7 Reset Switch 7 Connect Ethernet 7 Connect
More informationQuickSpecs. What's New HP 1.2TB 6G SAS 10K rpm SFF (2.5-inch) SC Enterprise 3yr Warranty Hard Drive
Overview Serial Attached SCSI (SAS) provides a superior storage solution. With some storage requirements escalating and others becoming more complex, factors such as flexibility, performance, increased
More informationUpgrading the MSA1000 for Enhanced Features
White Paper December 2002 Prepared by: Network Storage Solutions Hewlett Packard Company Contents Benefits of the MSA1000 Enhancements...1 Prerequisites...3 Environmental Monitoring Unit (EMU) issue:...3
More informationQuickSpecs. HPE Hard Disk Drives
DA - 12244 Worldwide Version 56 10.23.2017 Page 1 Overview HPE Hard Disk s HPE Hard Disk s (HDDs) delivers proven performance at industry leading capacities backed by high quality and reliability, preferred
More informationHPE Knowledge Article
HPE Knowledge Article HPE Integrated Lights-Out 4 (ilo 4) - How to Reset ilo Management Processor and ilo Password? Article Number mmr_sf-en_us000012649 Environment HPE Integrated Lights-Out 4 Issue Reset
More informationHPE MSA Storage Troubleshooting Guide
HPE MSA Storage Troubleshooting Guide Abstract This document provides information about troubleshooting HPE MSA Storage Systems. Use this document to troubleshoot and maintain Hewlett Packard Enterprise
More informationHPE VMware ESXi and vsphere 5.x, 6.x and Updates Getting Started Guide
HPE VMware ESXi and vsphere 5.x, 6.x and Updates Getting Started Guide Abstract This guide is intended to provide setup information for HPE VMware ESXi and vsphere. Part Number: 818330-003 Published: April
More informationSANnet II Manual Firmware Upgrade and Controller Recovery Step Guide - From 3.2x to 4.1x Guide
SANnet II Manual Firmware Upgrade and Controller Recovery Step Guide - From 3.2x to 4.1x Guide Page 1 of 7 Please read this document in its entirety before proceeding with the firmware upgrade or Controller
More informationOracle FS1-2 Flash Storage System. Customer Release Notes 6.1. Part Number E Oracle FS1-2 System release July
Oracle FS1-2 Flash Storage System Customer Release Notes 6.1 Part Number E57850-03 Oracle FS1-2 System release 06.01 2015 July Copyright 2005, 2015, Oracle and/or its affiliates. All rights reserved. This
More informationGetting Started. HP Business PCs
Getting Started HP Business PCs Copyright 2010 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Microsoft, Windows, Windows Vista, and Windows
More informationQuickSpecs. HPE SAS Hard Drives. Overview. What's New
HPE s Overview HPE s Serial Attached SCSI () provides a superior storage solution. With some storage requirements escalating and others becoming more complex, factors such as flexibility, performance,
More informationP3AM ENZ0. FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems. Operation Guide (Basic)
FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) This page is intentionally left blank. Preface Fujitsu would like to thank you for purchasing
More informationHP P6000 Enterprise Virtual Array
HP P6000 Enterprise Virtual Array The HP P6000 Enterprise Virtual Array (P6000 EVA) is an enterprise class virtual storage array family for midsized organizations at an affordable price. With built in
More informationHP VMware ESXi and vsphere 5.x and Updates Getting Started Guide
HP VMware ESXi and vsphere 5.x and Updates Getting Started Guide Abstract This guide is intended to provide setup information for HP VMware ESXi and vsphere. HP Part Number: 616896-409 Published: September
More informationUser Guide. Storage Executive. Introduction. Storage Executive User Guide. Introduction
Introduction User Guide Storage Executive Introduction This guide describes how to install and use Storage Executive to monitor and manage Micron solid state drives (SSDs). Storage Executive provides the
More informationQuickSpecs. HP 50 Modular Smart Array Enclosure. Overview
Overview The HP 50 Modular Smart Array (MSA50) Enclosure is a 1U Serial Attach SCSI(SAS) disk drive storage enclosure supporting Small Form Factor(SFF) SAS or Serial ATA(SATA) drives. This enclosure delivers
More informationExtended Search Administration
IBM Lotus Extended Search Extended Search Administration Version 4 Release 0.1 SC27-1404-02 IBM Lotus Extended Search Extended Search Administration Version 4 Release 0.1 SC27-1404-02 Note! Before using
More informationHPE OneView for Microsoft System Center Release Notes (v 8.2 and 8.2.1)
Center Release Notes (v 8.2 and 8.2.1) Part Number: 832154-004a Published: April 2017 Edition: 2 Contents Center Release Notes (v 8.2 and 8.2.1)... 4 Description...4 Update recommendation... 4 Supersedes...
More informationDominion SX Release Notes
Dominion SX Release Notes Dominion SX Release Notes and Compatibility Release 3.1.7 April 14, 2009 Document updated June 10, 2010 Contents Applicability... 2 Release Status... 2 Expiration Date of Content...
More informationHP ProLiant DL360 G7 Server - Overview
Menu Hewlett Packard Enterprise Support Center Search Notifications Help Settings HP ProLiant DL360 G7 Server - Overview Product description What's new Product features Software overview Important links
More informationUser Guide. Storage Executive Command Line Interface. Introduction. Storage Executive Command Line Interface User Guide Introduction
User Guide Storage Executive Command Line Interface Introduction Introduction This guide describes how to use Micron's Storage Executive command line interface (CLI) to monitor, manage, and configure Micron
More informationHPE StoreOnce 3100, 3500, 5100, and 5500 System Installation and Configuration Guide
HPE StoreOnce 3100, 3500, 5100, and 5500 System Installation and Configuration Guide Abstract This guide is for HPE StoreOnce System Administrators. It assumes that the user has followed the instructions
More informationSPECIFICATION FOR NETWORK ATTACHED STORAGE (NAS) TO BE FILLED BY BIDDER. NAS Controller Should be rack mounted with a form factor of not more than 2U
SPECIFICATION FOR NETWORK ATTACHED STORAGE (NAS) TO BE FILLED BY BIDDER S.No. Features Qualifying Minimum Requirements No. of Storage 1 Units 2 Make Offered 3 Model Offered 4 Rack mount 5 Processor 6 Memory
More informationDell EMC ME4 Series vsphere Client Plug-in
Dell EMC ME4 Series vsphere Client Plug-in User's Guide Regulatory Model: E09J, E10J, E11J Regulatory Type: E09J001, E10J001, E11J001 Notes, cautions, and warnings NOTE: A NOTE indicates important information
More informationHP Intelligent Provisioning 2.20 (Updated 09/2015)
HP Intelligent Provisioning 2.20 (Updated 09/2015) HP ProLiant Systems HP ProLiant BL Server Blades HP ProLiant BL460c Gen9 Server HP ProLiant BL660c Gen9 Server HP ProLiant DL Servers HP ProLiant DL60
More information